  1. Clinical outcomes between different stent designs with the same polymer and drug: comparison between the Taxus Express and Taxus Liberte stents.

    Science.gov (United States)

    Son, Jang-Won; Kim, Ung; Park, Jong-Seon; Kim, Young-Jo; Jang, Jae-Sik; Yang, Tae-Hyun; Kim, Dong-Soo; Kim, Dong-Kie; Seol, Sang-Hoon; Kim, Doo-Il; Nam, Chang-Wook; Hur, Seung-Ho; Kim, Kwon-Bae

    2013-01-01

    The Taxus Liberte stent (Boston Scientific Co.) evolved from the Taxus Express stent, with enhanced stent deliverability and uniform drug delivery. This study was designed to compare angiographic and clinical outcomes in real-world practice between the Taxus Liberte and Taxus Express stents. Between 2006 and 2008, 240 patients receiving the Taxus Liberte stent at three centers were registered and compared to historical control patients who had received the Taxus Express stent (n = 272). After propensity score matching, 173 patients treated with the Taxus Liberte stent and the same number of patients treated with the Taxus Express stent were selected. The primary outcome was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), ischemia driven target vessel revascularization (TVR), and stent thrombosis (ST) at 1 year. An additional angiographic assessment was conducted at 9 to 12 months. The study showed no significant difference between the Taxus Express and Taxus Liberte stents (death, 1.73% vs. 2.31%, p = 1.000; MI, 0% vs. 1.73%, p = 0.2478; TVR, 2.31% vs. 1.16%, p = 0.6848; and ST, 0% vs. 1.16%, p = 0.4986). The total MACE rate at 1 year did not differ between the groups (4.05% in Taxus Express vs. 4.05% in Taxus Liberte, p = 1.000). In addition, the binary restenosis rate did not differ (2.25% in Taxus Express vs. 1.80% in Taxus Liberte, p = 0.6848). In real-world experience with the two Taxus stent designs, both stents showed similarly good clinical and angiographic outcomes at 1 year. A long-term follow-up study is warranted.

  2. Economic modeling of new stent platforms to evaluate cost effectiveness: analysis of the TAXUS Liberté versus TAXUS express stents.

    Science.gov (United States)

    Turco, Mark A; Kansal, Anuraag R; Stern, Sean; Amorosi, Stacey L; Underwood, Paul L; Lissovoy, Greg D E; Dawkins, Keith D

    2012-08-01

    With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective. ©2012, Wiley Periodicals, Inc.

  3. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    Science.gov (United States)

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All

  4. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Directory of Open Access Journals (Sweden)

    Wehrenberg Scott

    2010-01-01

    Full Text Available Abstract Background Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials. Methods/Design The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1, single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express2 paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to Discussion The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at http://www.clinicaltrials.gov, identification numbers NCT00484315 and NCT00489541.

  5. Comparison of the safety and efficacy for application of (cypher)TM and (taxus)TM coronary stent in patients with coronary heart disease and concurrent diabetic

    International Nuclear Information System (INIS)

    Zhang Junjie; Chen Shaoliang; Chen Huaixin; Li Zhiheng; Lin Yanting

    2005-01-01

    Objective: To compare the relative safety and efficacy of Cypher and Taxus stent in coronary heart disease complicated with diabetes. Methods: A retrospective study of our hospital's Cardiology database containing one hundred and twenty-two CHD complicated with diabetes undergone selective or urgent implantation of DES stent between June 2002 and February 2004 were divided into Cypher stent group (n=31) and Taxus stent group (n=91). The endpoints included cardiac death ,myocardial infarction (MI) and TLR at 6-month. Results: 122 patients with majority of males (80%) and mean age of 56 ± 11 years. The baseline characteristics were similar in both groups. Majority lesions treated were consisted of AHA/ACC Type B2/C (75%). Compared to the Taxus group, the Cypher group had a smaller mean reference diameter (2.4±0.6 mm versus 2.6±0.7 mm, P TM and (Taxus) TM coronary stents are proved to be equally safe and effective with low rate of clinical restenosis, TLR and MACE at 6-month in coronary heart disease complicated with diabetes patients. (authors)

  6. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  7. gender-specific outcome after paclitaxel-eluting stent implantation in japanese patients with coronary artery disease--sub-analysis of the Japan TAXUS Express2 post-marketing survey.

    Science.gov (United States)

    Okura, Hiroyuki; Nakamura, Masato; Kotani, Jun-Ichi; Kozuma, Ken

    2013-01-01

     Although previous randomized and non-randomized studies have demonstrated the safety and efficacy of paclitaxel-eluting stents (PES), a higher revascularization rate has been reported in women than in men. A sub-analysis of the TAXUS Japan Post-market Surveillance Study (TAXUS-PMS) was done to assess the influence of gender on clinical outcome.  A total of 2,132 PES-treated Japanese patients (women, n=551) from this registry were analyzed. Subjects were stratified by gender to compare 1-year clinical outcome. PES-treated women were older and more likely to have insulin-treated diabetes and hypertension. In contrast, PES-treated men were more likely to be smokers, have a previous history of myocardial infarction, and lower ejection fraction. While cardiac death, myocardial infarction and stent thrombosis were similar between men and women, major cardiac events tended to be lower in women than in men (6.4% vs. 8.8%, P=0.08). Although women had significantly smaller reference vessel size (2.46±0.53 mm vs. 2.59±0.60 mm, Ptarget lesion revascularization rate was significantly lower in women than in men (4.2% vs. 6.5%, P<0.05).  Despite a higher risk profile, Japanese women treated with PES did not have a higher rate of repeat revascularization or major adverse clinical outcome than PES-treated men at 1 year. 

  8. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    Science.gov (United States)

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  9. Solving the Issue of Restenosis After Stenting of Intracranial Stenoses: Experience with Two Thin-Strut Drug-Eluting Stents (DES)—Taxus Element™ and Resolute Integrity™

    Energy Technology Data Exchange (ETDEWEB)

    Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany); Fischer, Sebastian [Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin (Germany); Arnold, Guy [Klinikverbund Südwest, Klinikum Sindelfingen, Klinik für Neurologie (Germany); Schmid, Elisabeth; Bäzner, Hansjörg [Klinikum Stuttgart, Klinik für Neurologie (Germany); Henkes, Hans [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany)

    2015-06-15

    PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Patients and MethodsWe retrospectively reviewed all patients treated with Taxus Element™ or Resolute Integrity™ stent for an intracranial atherosclerotic stenosis between March 2011 and August 2013. Technical success was defined as the ability to deploy the device at the desired location and reduce the degree of stenosis below 50 %. All procedure-related strokes were recorded. Control angiography was scheduled after 6 weeks, 3, 6, and 12 months and yearly thereafter. A luminal narrowing ≥50 % was regarded as a restenosis. Stroke recurrence in the territory of the treated artery was reported.ResultsIn the defined period we treated 101 patients harboring 117 intracranial stenoses. The procedure was successful in 100 (85.5 %) lesions. Procedure-related strokes occurred in 10 (9.9 %) patients with a permanent morbidity in 3 (3.0 %). Follow-up angiography was available for 83 of 100 (83.0 %) successfully treated lesions with an average of 355 days (IQR 153–482 days). Three (3.6 %) asymptomatic restenoses were detected. All occurred after treatment with Resolute Integrity™, none after Taxus Element™ (p = 0.059). New strokes in the territory of the treated artery were encountered in 2 (2.6 %) occasions.ConclusionThin-strut DES improve long-term patency and reduce the risk of subsequent stroke. Differences between devices may exist. Feasibility is comparable to bare-metal balloon-mounted stents and procedure-related strokes occurred within the expected range.

  10. Comparison of the sirolimus-eluting versus paclitaxel-eluting coronary stent in patients with diabetes mellitus: the diabetes and drug-eluting stent (DiabeDES) randomized angiography trial

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette Okkels; Galloe, Anders Michael

    2008-01-01

    group (0.23 +/- 0.54 vs 0.44 +/- 0.52 mm, p = 0.025). Angiographic in-segment restenosis at 8-month follow-up, a secondary end point, was present in 16 patients (Cypher, n = 6; Taxus, n = 10; p = 0.24). Target lesion revascularization was performed in 5 patients (6.5%) and 9 patients (11.......8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite...

  11. Randomized comparison between intracoronary β-radiation brachytherapy and implantation of paclitaxel-eluting stents for the treatment of diffuse in-stent restenosis

    International Nuclear Information System (INIS)

    Schukro, Christoph; Syeda, Bonni; Kirisits, Christian; Schmid, Rainer; Pichler, Philipp; Pokrajac, Boris; Lang, Irene; Poetter, Richard; Glogar, Dietmar

    2007-01-01

    Background and purpose: Intracoronary brachytherapy was the primary therapeutic option for the treatment of in-stent restenosis (ISR) during the last years. Especially for the treatment of diffuse ISR (lesions >10 mm), β-source brachytherapy was significantly superior to singular balloon angioplasty. Despite lacking clinical database, the implantation of drug eluting stents recently became a common procedure for the treatment of ISR. This randomized trial aimed to compare the efficacy of β-brachytherapy with β-radioisotopes 90 Sr/ 90 Y and paclitaxel-eluting stent implantation for the treatment of diffuse ISR. Material and methods: Thirty-seven patients with diffuse ISR were randomly assigned to β-brachytherapy after balloon angioplasty (Beta-Cath TM in 17 patients) or paclitaxel-eluting stent implantation (Taxus-Express2 TM in 20 patients). Six-month clinical follow-up was obtained for all patients, while angiographic follow-up was available for 30 patients. Results: Binary ISR (restenosis >50%) within target segment was observed in three patients treated with Beta-Cath TM , of which one needed target segment revascularisation for recurrent ISR, whereas no significant restenosis occurred in the patients treated with Taxus-Express2 TM (P = 0.037). No further major adverse cardiac (target segment revascularisation, myocardial infarction, death) was found in either group (P = NS). Stent implantation was the more time-saving (31 ± 11 min versus 60 ± 23 min, P TM arm, we found no difference in clinical outcome after implantation of paclitaxel-eluting stents for the treatment of diffuse ISR when compared to β-brachytherapy

  12. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  13. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  14. Comparison of a Simple Angiographic Approach With a Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery Score-Based Approach for Left Main Coronary Artery Stenting: A Pooled Analysis of Serial PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery Versus Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease) Studies.

    Science.gov (United States)

    Lee, Pil Hyung; Lee, Jong-Young; Lee, Cheol Whan; Kim, Seon-Ok; Ahn, Jung-Min; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Park, Seung-Jung

    2018-01-01

    The applicability of Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery scores to left main coronary artery disease (CAD) has been questioned. A simplified alternative is needed for guiding decision making. We evaluated the prognostic value of a simplified angiographic classification in comparison with a Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score-based approach for patients with left main CAD undergoing drug-eluting stent implantation. The proposed approach classified left main CAD as either extensive (n=819), defined as left main bifurcation lesions with an involvement of ostial left circumflex artery or as any left main lesion plus multivessel CAD, or limited (n=453), defined as ostial/midshaft lesions or left main bifurcation lesions without an involvement of ostium of left circumflex artery, alone or plus 1-vessel disease. The databases from 4 prospective Premier of Randomized Comparison of Bypass Surgery versus Angioplasty Using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease studies were pooled, and the primary outcome was a major adverse cardiac event, defined as death, myocardial infarction, or repeat revascularization. During follow-up (median 38 months; interquartile range, 36-61 months), the risk for major adverse cardiac event was significantly higher with extensive than with limited left main CAD (adjusted hazard ratio, 2.13; 95% confidence interval, 1.54-2.94; P Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score tertiles did not effectively stratify these 2 outcome measures. Compared with Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery scores, the simpler angiographic approach provided better discrimination for future cardiovascular events in patients with left main CAD undergoing drug-eluting stent implantation. © 2018 American Heart Association, Inc.

  15. Propensity score matched lesion-based comparison of long-term clinical and angiographic outcomes after placement of sirolimus (Cypher Bx Velocity) and paclitaxel (TAXUS Express)-eluting stents for de novo native coronary stenosis.

    Science.gov (United States)

    Nakano, Yosuke; Ishikawa, Tetsuya; Hino, Shoryoku; Mutoh, Makoto

    2014-04-01

    Long-term clinical and angiographic outcomes after sirolimus (SES: Cypher Bx Velocity) and paclitaxel (PES: TAXUS Express)-eluting stent implantation were firstly compared in Japan. During PES-available period from May 2007 to February 2009, 1068 nonrandomized consecutive de novo native coronary lesions treated either with a PES (682 lesions) or SES were enrolled in this study, and a retrospective examination was conducted in April 2013. During that interval, the use ratio of drug-eluting stent (i.e. SES plus PES) was 94.2 %. By adjusting the baselines with a propensity score matching analysis produced 383 lesions in each arm, the incidence of the clinical endpoint (1500-day cardiac death, nonfatal recurrent myocardial infarction, and definite stent thrombosis) after placement of SES (2.1 %; mean follow-up, 1400 ± 290 days) was not significantly different from that in the PES group (2.6 %; 1394 ± 325 days, p = 0.637). SES did not relate to the clinical endpoint (hazard ratio 1.04; 95 % CI 0.29-3.76; p = 0.949). In the baseline-adjusted angiographic followed up lesions (n = 234 in each arm), the incidence of binary restenosis (percent diameter stenosis [%DS] >50 %) in the SES group (12.0 %; mean follow-up, 477 ± 281 days) was not significantly different from that in the PES group (14.5 %; 497 ± 341 days, p = 0.431). SES did not relate to binary restenosis (Odds ratio 0.73; 95 % CI 0.40-1.32; p = 0.295). In conclusion, the present propensity score matched lesion-based analysis firstly showed the statistical equivalent long-term clinical and angiographic outcomes after either SES or PES placement for de novo native coronary lesion in Japanese patients in a daily practice environment.

  16. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    Science.gov (United States)

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Taxus ingredients in the red arils of Taxus baccata L. determined by HPLC-MS/MS.

    Science.gov (United States)

    Siegle, Lydia; Pietsch, Jörg

    2018-02-09

    Taxus baccata L. is an evergreen conifer whose plant parts are cardiotoxic. Only the red arils of the berries are described as non-toxic and taxane-free. Extraction and HPLC-MS/MS methods were developed for the investigation of the Taxus compounds 3,5-dimethoxyphenol, 10-deacetylbaccatin III, baccatin III, cephalomannine, taxol A and taxinine M in the red arils of the yew berries. MethodologyA liquid-liquid extraction method for the red arils of the fruits from three yews were developed. An accurate (ESI+) HPLC-MS/MS method was performed for the simultaneous detection and determination of the target compounds in multiple reaction monitoring (MRM) mode. All Taxus agents obtained were detected in the red arils. Highest concentrations were determined for baccatin III and 10-deacetylbaccatin III. The developed quantitative method is reliable and selective and was successfully applied for quantification of selected Taxus ingredients in red arils of Taxus baccata. It was disproved that the red arils of the berries do not contain the selected Taxus compounds. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  19. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    Science.gov (United States)

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  20. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    Science.gov (United States)

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  1. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  2. Frequency of Angina Pectoris After Percutaneous Coronary Intervention and the Effect of Metallic Stent Type.

    Science.gov (United States)

    Gaglia, Michael A; Torguson, Rebecca; Lipinski, Michael J; Gai, Jiaxiang; Koifman, Edward; Kiramijyan, Sarkis; Negi, Smita; Rogers, Toby; Steinvil, Arie; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-02-15

    Although metallic coronary stents significantly reduce angina pectoris compared with optimal medical therapy, angina after percutaneous coronary intervention (PCI) remains frequent. We, therefore, sought to compare the incidence of any angina during the 1 year after PCI among the spectrum of commercially available metallic stents. Metallic stent type was classified as bare metal stent, Cypher, Taxus Express, Xience V, Promus Element, and Resolute. The primary end point was patient-reported angina within 1 year of PCI. Multivariable logistic regression was performed to assess the independent association of stent type with any angina at 1 year. Overall, 8,804 patients were queried in regard to angina symptoms; 32.3% experienced angina at some point in the first year after PCI. Major adverse cardiovascular events, a composite of all-cause mortality, target vessel revascularization, and Q-wave myocardial infarction, increased with angina severity: 6.8% for patients without angina, 10.0% for patients with class 1 or 2 angina, and 19.7% for patients with class 3 or 4 angina (p angina at 1 year after PCI. Baseline Canadian Cardiovascular Society class 3 or 4 angina, history of coronary artery bypass grafting, and history of PCI were associated with a higher likelihood of angina at 1 year; increasing age, male gender, presentation with acute coronary syndrome, and higher stented length were associated with less angina. In conclusion, metallic stent type is not associated with the occurrence of angina at up to 1 year after PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. [Research progress and trend analysis of biology and chemistry of Taxus medicinal resources].

    Science.gov (United States)

    Hao, Da-Cheng; Xiao, Pei-Gen; Peng, Yong; Liu, Ming; Huo, Li

    2012-07-01

    Taxus is the source plant of anti-cancer drug paclitaxel and its biosynthetic precursor, analogs and derivatives, which has been studying for decades. There are many endemic Taxus species in China, which have been studied in the field of multiple disciplines. Based on the recent studies of the researchers, this review comments on the study of Taxus biology and chemistry. The bibliometric method is used to quantify the global scientific production of Taxus-related research, and identify patterns and tendencies of Taxus-related articles. Gaps are present in knowledge about the genomics, epigenomics, transcriptomics, proteomics, metabolomics and bioinformatics of Taxus and their endophytic fungi. Systems biology and various omics technologies will play an increasingly important role in the coming decades.

  4. Transcriptomic Response of Chinese Yew (Taxus chinensis to Cold Stress

    Directory of Open Access Journals (Sweden)

    Xianghua Yu

    2017-04-01

    Full Text Available Taxus chinensis is a rare and endangered shrub, highly sensitive to temperature changes and widely known for its potential in cancer treatment. How gene expression of T. chinensis responds to low temperature is still unknown. To investigate cold response of the genus Taxus, we obtained the transcriptome profiles of T. chinensis grown under normal and low temperature (cold stress, 0°C conditions using Illumina Miseq sequencing. A transcriptome including 83,963 transcripts and 62,654 genes were assembled from 4.16 Gb of reads data. Comparative transcriptomic analysis identified 2,025 differently expressed (DE isoforms at p < 0.05, of which 1,437 were up-regulated by cold stress and 588 were down-regulated. Annotation of DE isoforms indicated that transcription factors (TFs in the MAPK signaling pathway and TF families of NAC, WRKY, bZIP, MYB, and ERF were transcriptionally activated. This might have been caused by the accumulation of secondary messengers, such as reactive oxygen species (ROS and Ca2+. While accumulation of ROS will have caused damages to cells, our results indicated that to adapt to low temperatures T. chinensis employed a series of mechanisms to minimize these damages. The mechanisms included: (i cold-enhanced expression of ROS deoxidant systems, such as peroxidase and phospholipid hydroperoxide glutathione peroxidase, to remove ROS. This was further confirmed by analyses showing increased activity of POD, SOD, and CAT under cold stress. (ii Activation of starch and sucrose metabolism, thiamine metabolism, and purine metabolism by cold-stress to produce metabolites which either protect cell organelles or lower the ROS content in cells. These processes are regulated by ROS signaling, as the “feedback” toward ROS accumulation.

  5. Efetividade e segurança dos stents farmacológicos em um serviço de cardiologia em Curitiba-PR Efectividad y seguridad de los Stents farmacológicos en un servicio de cardiología en Curitiba-PR Effectiveness and safety of drug-eluting stents in a cardiology clinic in Curitiba, PR, Brazil

    Directory of Open Access Journals (Sweden)

    Chiu Yun Yu Braga

    2010-07-01

    Full Text Available FUNDAMENTO: A efetividade e segurança de stents farmacológicos (SF ainda têm sido questionadas. OBJETIVO: O objetivo deste estudo foi avaliar a efetividade e segurança desses stents, e a incidência da revascularização da lesão tratada (RLT, além de identificar possíveis variáveis que influenciam a necessidade de RLT. MÉTODOS: Selecionaram-se 203 pacientes do Hospital Costantini que tiveram acompanhamento clínico no período de 1 a 3 anos. RESULTADOS: Observou-se o seguinte quadro: 470 lesões; 171 (84,24% pacientes eram homens; 54 (26,6%, diabéticos; 131 (64,35%, hipertensos; 127 (62,56%, dislipidêmicos; 40 (19,70%, tabagistas; e 79 (38,92% apresentavam história familiar de coronariopatia. Ainda: 49 (24,14% pacientes apresentavam angina estável; 58 (28,57%, angina instável; e 6 (2,96%, infarto agudo do miocárdio. Desses pacientes, 85 (41,87% eram assintomáticos, e 146 (71,92%, multiarteriais. Nas características das lesões, 77,45% foram B2/C (AHA/ACC. Taxus foi implantado em 73,62% dos pacientes. Em 381 (81,96%, constataram-se stents com diâmetro > 2,5 mm. O comprimento de stent era FUNDAMENTO: La efectividad y seguridad de stents farmacológicos (SF han sido cuestionadas. OBJETIVO: El objetivo de este estudio fue evaluar la efectividad y seguridad de esos stents, y la incidencia de la revascularización de la lesión tratada (RLT, además de identificar posibles variables que influyen la necesidad de RLT. MÉTODOS: Se seleccionaron 203 pacientes del Hospital Costantini que tuvieron acompañamiento clínico en el período de 1 a 3 años. RESULTADOS: Se observó el siguiente cuadro: 470 lesiones; 171 (84,24% pacientes eran hombres; 54 (26,6%, diabéticos; 131 (64,35%, hipertensos; 127 (62,56%, dislipidémicos; 40 (19,70%, tabaquistas; y 79 (38,92% presentaban historia familiar de coronariopatía. Además: 49 (24,14% pacientes presentaban angina estable; 58 (28,57%, angina inestable; y 6 (2,96%, infarto agudo de miocardio

  6. Bacterial diversity of Taxus rhizosphere: culture-independent and culture-dependent approaches.

    Science.gov (United States)

    Hao, Da Cheng; Ge, Guang Bo; Yang, Ling

    2008-07-01

    The regional variability of Taxus rhizosphere bacterial community composition and diversity was studied by comparative analysis of three large 16S rRNA gene clone libraries from the Taxus rhizosphere in different regions of China (subtropical and temperate regions). One hundred and forty-six clones were screened for three libraries. Phylogenetic analysis of 16S rRNA gene sequences demonstrated that the abundance of sequences affiliated with Gammaproteobacteria, Betaproteobacteria, and Actinobacteria was higher in the library from the T. xmedia rhizosphere of the temperate region compared with the subtropical Taxus mairei rhizosphere. On the other hand, Acidobacteria was more abundant in libraries from the subtropical Taxus mairei rhizosphere. Richness estimates and diversity indices of three libraries revealed major differences, indicating a higher richness in the Taxus rhizosphere bacterial communities of the subtropical region and considerable variability in the bacterial community composition within this region. By enrichment culture, a novel Actinobacteria strain DICP16 was isolated from the T. xmedia rhizosphere of the temperate region and was identified as Leifsonia shinshuensis sp. via 16S rRNA gene and gyrase B sequence analyses. DICP16 was able to remove the xylosyl group from 7-xylosyl-10-deacetylbaccatin III and 7-xylosyl-10-deacetylpaclitaxel, thereby making the xylosyltaxanes available as sources of 10-deacetylbaccatin III and the anticancer drug paclitaxel. Taken together, the present studies provide, for the first time, the knowledge of the biodiversity of microorganisms populating Taxus rhizospheres.

  7. Deep sequencing reveals transcriptome re-programming of Taxus × media cells to the elicitation with methyl jasmonate.

    Science.gov (United States)

    Sun, Guiling; Yang, Yanfang; Xie, Fuliang; Wen, Jian-Fan; Wu, Jianqiang; Wilson, Iain W; Tang, Qi; Liu, Hongwei; Qiu, Deyou

    2013-01-01

    Plant cell culture represents an alternative source for producing high-value secondary metabolites including paclitaxel (Taxol®), which is mainly produced in Taxus and has been widely used in cancer chemotherapy. The phytohormone methyl jasmonate (MeJA) can significantly increase the production of paclitaxel, which is induced in plants as a secondary metabolite possibly in defense against herbivores and pathogens. In cell culture, MeJA also elicits the accumulation of paclitaxel; however, the mechanism is still largely unknown. To obtain insight into the global regulation mechanism of MeJA in the steady state of paclitaxel production (7 days after MeJA addition), especially on paclitaxel biosynthesis, we sequenced the transcriptomes of MeJA-treated and untreated Taxus × media cells and obtained ∼ 32.5 M high quality reads, from which 40,348 unique sequences were obtained by de novo assembly. Expression level analysis indicated that a large number of genes were associated with transcriptional regulation, DNA and histone modification, and MeJA signaling network. All the 29 known genes involved in the biosynthesis of terpenoid backbone and paclitaxel were found with 18 genes showing increased transcript abundance following elicitation of MeJA. The significantly up-regulated changes of 9 genes in paclitaxel biosynthesis were validated by qRT-PCR assays. According to the expression changes and the previously proposed enzyme functions, multiple candidates for the unknown steps in paclitaxel biosynthesis were identified. We also found some genes putatively involved in the transport and degradation of paclitaxel. Potential target prediction of miRNAs indicated that miRNAs may play an important role in the gene expression regulation following the elicitation of MeJA. Our results shed new light on the global regulation mechanism by which MeJA regulates the physiology of Taxus cells and is helpful to understand how MeJA elicits other plant species besides Taxus.

  8. Identification of antifungal activity substances on seedborn disease from garlic and taxus extracts

    Energy Technology Data Exchange (ETDEWEB)

    Chung, I.M.; Paik, S.B. [Konkuk University, Seoul (Korea, Republic of)

    1999-02-01

    Antifungal substances were isolated and identified from garlic and taxus extracts to develop safe and broad fungicide. The inhibitory effect of seedborn disease of sesame, pepper, radish, chinese cabbage by formulation of antifungal substances was investigated. The antifungal substance isolated through column chromatography from garlic and taxus extracts was confirmed by GC-MS as allicin (C{sub 6}H{sub 10}OS{sub 2}) and taxol(C{sub 47}H{sub 51}NO{sub 14}) and the quantified content from each extracts by HPLC analysis was 0.62%, 0.29%, respectively. The formulation composed of garlic and taxus extracts controlled effectively the seedborn fungi tested in this study at 10X dilution, but at 100X dilution the inhibitory effect decreased. Phytotoxicity of these formulations did not recognized. 22 refs., 6 figs., 5 tabs.

  9. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Denise Oliveira, E-mail: dennizmo@yahoo.com.br; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo [Hospital São Lucas PUC, Porto Alegre, RS (Brazil)

    2014-09-15

    Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. To evaluate the efficacy and safety of drug-eluting stents in the real world. We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the 'real world' may benefit from drug-eluting stenting with excellent, long-term results.

  10. Assessment of genetic and epigenetic variation during long-term Taxus cell culture.

    Science.gov (United States)

    Fu, Chunhua; Li, Liqin; Wu, Wenjuan; Li, Maoteng; Yu, Xiaoqing; Yu, Longjiang

    2012-07-01

    Gradual loss of secondary metabolite production is a common obstacle in the development of a large-scale plant cell production system. In this study, cell morphology, paclitaxel (Taxol®) biosynthetic ability, and genetic and epigenetic variations in the long-term culture of Taxus media cv Hicksii cells were assessed over a 5-year period to evaluate the mechanisms of the loss of secondary metabolites biosynthesis capacity in Taxus cell. The results revealed that morphological variations, gradual loss of paclitaxel yield and decreased transcriptional level of paclitaxel biosynthesis key genes occurred during long-term subculture. Genetic and epigenetic variations in these cultures were also studied at different times during culture using amplified fragment-length polymorphism (AFLP), methylation-sensitive amplified polymorphism (MSAP), and high-performance liquid chromatography (HPLC) analyses. A total of 32 primer combinations were used in AFLP amplification, and none of the AFLP loci were found to be polymorphic, thus no major genetic rearrangements were detected in any of the tested samples. However, results from both MSAP and HPLC indicated that there was a higher level of DNA methylation in the low-paclitaxel yielding cell line after long-term culture. Based on these results, we proposed that accumulation of paclitaxel in Taxus cell cultures might be regulated by DNA methylation. To our knowledge, this is the first report of increased methylation with the prolongation of culture time in Taxus cell culture. It provides substantial clues for exploring the gradual loss of the taxol biosynthesis capacity of Taxus cell lines during long-term subculture. DNA methylation maybe involved in the regulation of paclitaxel biosynthesis in Taxus cell culture.

  11. Impact of Drug Metabolism/Pharmacokinetics and Their Relevance upon Taxus-based Drug Development.

    Science.gov (United States)

    Hao, Da-Cheng; Ge, Guang-Bo; Wang, Ping; Yang, Ling

    2018-05-22

    Drug metabolism and pharmacokinetic (DMPK) studies of Taxus natural products, their semi-synthetic derivatives and analogs are indispensable in the optimization of lead compounds and clinical therapy. These studies can lead to development of new drug entities with improved absorption, distribution, metabolism, excretion and toxicity (ADME/T) profiles. To date, there have been no comprehensive reviews of the DMPK features of Taxus derived medicinal compounds.Natural and semi-synthetic taxanes may cause and could be affected by drug-drug interaction (DDI). Hence ADME/T studies of various taxane-containing formulations are important; to date these studies indicate that the role of cytochrome p450s and drug transporters is more prominent than phase II drug metabolizing enzymes. Mechanisms of taxane DMPK mediated by nuclear receptors, microRNAs, and single nucleotide polymorphisms are being revealed. Herein we review the latest knowledge on these topics, as well as the gaps in knowledge of the DMPK issues of Taxus compounds. DDIs significantly impact the PK/pharmacodynamics performance of taxanes and co-administered chemicals, which may inspire researchers to develop novel formula. While the ADME/T profiles of some taxanes are well defined, DMPK studies should be extended to more Taxus compounds, species, and Taxus -involved formulations, which would be streamlined by versatile omics platforms and computational analyses. Further biopharmaceutical investigations will be beneficial tothe translation of bench findings to the clinical applications. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Paclitaxel-eluting stents versus everolimus-eluting coronary stents in a diabetic population: two-year follow-up of the TUXEDO-India trial.

    Science.gov (United States)

    Kaul, Upendra; Bhagwat, Ajit; Pinto, Brian; Goel, Praveen K; Jagtap, Prashant; Sathe, Shireesh; Wander, Gurpreet S; Arambam, Priyadarshini; Bangalore, Sripal

    2017-11-20

    The aim of this study was to report whether the superiority of the everolimus-eluting stent (EES) vs. the paclitaxel-eluting stent (PES) at one-year follow-up in the Taxus Element versus Xience Prime in a Diabetic Population (TUXEDO)-India trial was sustained at longer-term follow-up. One thousand eight hundred and thirty (1,830) patients with diabetes mellitus and coronary artery disease were randomised to EES vs. PES. Follow-up data up to two years were available in 1,701 (92.9%) patients. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischaemia-driven target vessel revascularisation (TVR). Treatment with EES had a lower two-year rate of TVF (4.3% vs. 6.6%, p=0.03). Of the secondary endpoints, EES significantly reduced any MI (1.6% vs. 3.5%, p=0.01), TV-MI (0.7% vs. 3.1%, p=0.0001), ST (0.4% vs. 2.2%, p=0.001), cardiac death or target vessel MI (2.9% vs. 4.8%, p=0.04) and TLR (1.9% vs. 3.7%, p=0.02), compared with PES. Between one year and two years, no significant differences in the clinical outcomes were observed (pinteraction >0.05). In this adequately powered trial, the benefits of EES vs. PES in a diabetic population seen at one year were maintained at two years.

  13. Assessment of Anti-inflammatory Activity of Taxus Baccata Linn. Bark Extract.

    Science.gov (United States)

    Dutta, Satyajit; Mariappan, G; Sarkar, Dipankar; Sarkar, Piyali

    2010-01-01

    Taxus baccata (L) known as Sthauneyaka in Sanskrit(1) has wide range of biological activities including analgesic, anti-malarial, anti-rheumatic, sedative, anti-spasmodic, aphrodisiac and anti-asthmatic. In the present study, the dried and powdered bark of Taxus baccata (L) was extracted with 95% ethanol and ether at room temperature and screened for their anti--inflammatory activity by Carrageenan-induced paw edema method in rat. 95% ethanol extract exhibits potent anti-inflammatory activity at 200mg/kg four hours after administration in comparison with ether extract, as well reference standard, Aspirin. The observed pharmacological activities provide a scientific basis for the folklore use of the plant in treating acute inflammation.

  14. Solvent optimization on Taxol extraction from Taxus baccata L., using HPLC and LC-MS

    Directory of Open Access Journals (Sweden)

    H Sadeghi-aliabadi

    2009-10-01

    Full Text Available "nBackground and the purpose of the study: Taxol, a natural antitumor agent, was first isolated from the extract of the bark of Taxus brevifolia Nutt., which is potentially a limited source for Taxol. In the search of an alternative source, optimum and cost benefit extracting solvents, various solvents with different percentage were utilized to extract Taxol from needles of Taxus baccata. "nMethods: One g of the dried needles of Taxus baccata, collected from Torkaman and Noor cities of Iran, was extracted with pure ethanol or acetone and 50% and 20% of ethanol or acetone in water. Solvents were evaporated to dryness and the residues were dissolved in 5 ml of methanol and filtered. To one ml of the filtrate was added 50 μl of cinamyl acetate as the internal standard and 20 μl of the resulting solution was subjected to the HPLC to determine the extraction efficiencies of tested solvents. Five μl of filtrate was also subjected to the LC-MS using water/acetonitrile (10/90 as mobile phase and applying positive electrospray ionization (ESI to identify the authenticity of Taxol. "nResults: Results of this study indicated that Taxol extraction efficiency was enhanced as the percentage of ethanol or acetone was increased. HPLC analysis showed that Taxol could be quantified by UV detection using standard curve. The standard curve covering the concentration ranges of 7.8 - 500 μg/ml was linear (r2= 0.9992 and CV% ranged from 0.52 to 15.36. LC-MS analysis using ESI in positive-ion mode confirmed the authenticity of Taxol (m/z 854; M+H, as well as some adduct ions such as M+Na (m/z 876, M+K (m/z 892 and M+CH3CN+H2O (m/z 913. "nConclusions: The results suggest that 100% acetone is the best solvent for the extraction of Taxol from Taxus baccata needles.

  15. Bio-ecology of Taxus Baccata l. in Kakheti

    Directory of Open Access Journals (Sweden)

    Tamar Nadiradze

    2013-01-01

    Full Text Available The article discusses the bio-ecology of Taxus baccata L. in Kakheti (eastern Georgia, particularly in Tsinandali Park. Yew (Taxus baccata L. preserved in Tsinandali Park (Telavi region, Georgia was chosen as an object for long-lasting observation over plant vegetation. Vegetation of 47 new specimens were studied during the period 2001-2010. It was observed the buds opening, the vegetation finishing, the cambium active periods beginning and finishing, the sprout stiffen process, the rate and time of growth. The period between 2001 and 2004 is distinguished by the relatively intensive growth of yew samples. In 2004-2010 growth period was shortened. It is suggested, that shortening often growth period in yew specimen is related to the deficit of water in soil due to frequent drought and snowless winters in Telavi region in the last decade.Observation conducted on the peculiarities of cambial growth confirms that yew has strong ability of frost-resistance. We consider that the bio-ecological studies of yew tree, as an endangered species, and its implementation in decorative gardening will contribute to its conservation

  16. Reversal of cisplatin resistance in non-small cell lung cancer stem cells by Taxus chinensis var.

    Science.gov (United States)

    Jiang, Y Q; Xu, X P; Guo, Q M; Xu, X C; Liu, Q Y; An, S H; Xu, J L; Su, F; Tai, J B

    2016-09-02

    Drug resistance in cells is a major impedance to successful treatment of lung cancer. Taxus chinensis var. inhibits the growth of tumor cells and promotes the synthesis of interleukins 1 and 2 and tumor necrosis factor, enhancing immune function. In this study, T. chinensis var.-induced cell death was analyzed in lung cancer cells (H460) enriched for stem cell growth in a defined serum-free medium. Taxus-treated stem cells were also analyzed for Rhodamine 123 (Rh-123) expression by flow cytometry, and used as a standard functional indicator of MDR. The molecular basis of T. chinensis var.-mediated drug resistance was established by real-time PCR analysis of ABCC1, ABCB1, and lung resistance-related protein (LRP) mRNA, and western blot analysis of MRP1, MDR1, and LRP. Our results revealed that stem cells treated with higher doses of T. chinensis var. showed significantly lower growth inhibition rates than did H460 cells (P var. and cisplatin was also significantly inhibited (P var. (P var.-treated stem cells showed significant downregulation of the ABCC1, ABCB1, and LRP mRNA and MRP1, MDR1, and LRP (P var.-mediated downregulation of MRP1, MDR1, and LRP might contribute to the reversal of drug resistance in non-small cell lung cancer stem cells.

  17. Transcriptome-wide identification and screening of WRKY factors involved in the regulation of taxol biosynthesis in Taxus chinensis.

    Science.gov (United States)

    Zhang, Meng; Chen, Ying; Nie, Lin; Jin, Xiaofei; Liao, Weifang; Zhao, Shengying; Fu, Chunhua; Yu, Longjiang

    2018-03-26

    WRKY, a plant-specific transcription factor family, plays important roles in pathogen defense, abiotic cues, phytohormone signaling, and regulation of plant secondary metabolism. However, little is known about the roles, functions, and mechanisms of WRKY in taxane biosynthesis in Taxus spp. In this study, 61 transcripts were identified from Taxus chinensis transcriptome datasets by using hidden Markov model search. All of these transcripts encoded proteins containing WRKY domains, which were designated as TcWRKY1-61. After phylogenetic analysis of the WRKY domains of TcWRKYs and AtWRKYs, 16, 8, 10, 14, 5, 7, and 1 TcWRKYs were cladded into Group I, IIa-IIe, and III, respectively. Then, six representative TcWRKYs were selected to classify their effects on taxol biosynthesis. After MeJA (methyl jasmonate acid) and SA (salicylic acid) treatments, all of the six TcWRKYs were upregulated by MeJA treatment. TcWRKY44 (IId) and TcWRKY47 (IIa) were upregulated, whereas TcWRKY8 (IIc), TcWRKY20 (III), TcWRKY26 (I), TcWRKY41 (IIe), and TcWRKY52 (IIb) were downregulated by SA treatment. Overexpression experiments showed that the six selected TcWRKYs exerted different effects on taxol biosynthesis. In specific, TcWRKY8 and TcWRKY47 significantly improved the expression levels of taxol-biosynthesis-related genes. Transcriptome-wide identification of WRKY factors in Taxus not only enhances our understanding of plant WRKY factors but also identifies candidate regulators of taxol biosynthesis.

  18. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  19. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  20. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  1. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    Science.gov (United States)

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Influence of 103Pd radioactive stent on apoptosis of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Liu Yingmei; Wu Wei; Chen Xiaochao; Zhang Xuming; Wang Jingfeng; Wei Yulin; Yang Li

    2003-01-01

    Objective: To evaluate the influence of 103 Pd radioactive stent on apoptosis and its relative genes bcl-2 and bax in injured vascular media smooth muscle cells of rabbit abdominal arteries and to investigate the mechanism of 103 Pd radioactive stent for preventing restenosis after angioplasty. Methods: Fifty male New Zealand rabbits were randomized into stent group and 103 Pd stent group. Each group was subdivided into 5 sub-groups. Control group was set up. The study arteries were harvested at 3, 7, 14, 28 and 56 d after stenting and the pathomorphology, apoptosis analysis and in situ hybridization were performed to evaluate the expression of bcl-2 and bax mRNA. Results: The severity of the restenosis in 103 Pd stent group was less than that of stent group. It was most obvious at the 56th day (P 103 Pd stent group had much more apoptosis of vascular smooth muscle cells than stent group did and reached the peak at the 7th day, (14.72±0.53)% vs (12.42±1.13)% (P 103 Pd stent group was much lower than that of stent group at 3 to 28 d. The difference was most obvious at the 28th day after stenting, (18.43± 0.67)% vs (21.55±0.93)% (P 103 Pd stent group was higher than that of stent group, the peak was at the 7th day, (11.17±0.94)% vs (9.30±1.01)%. The ratio of bcl-2/bax in 103 Pd stent group was much lower than that of stent group at 3 to 28 d. Linear correlation analysis showed that there was significant negative correlation between bcl-2 mRNA and apoptosis. Between bax mRNA and apoptosis, the positive correlation was found (P 103 Pd radioactive stent induced more significant apoptosis in vascular media smooth muscle cells by promoting the expression of apoptosis related genes and relieved the expanding of restenosis

  4. Differential impact of five coronary devices on plaque size: insights from the ABSORB and SPIRIT trials.

    Science.gov (United States)

    García-García, Héctor M; Serruys, Patrick W; Campos, Carlos M; Onuma, Yoshinobu

    2014-08-20

    Coronary plaque size modification, by either local (device) or systemic treatments, has been the target for many years. From ABSORB Cohort A (Absorb BVS 1.0), ABSORB Cohort B (Absorb BVS 1.1), SPIRIT FIRST (Multi-Link Vision vs. Xience V) & SPIRIT II (Xience V vs. Taxus), we calculated the total plaque area (vessel minus lumen area - thus it comprises both compartments - the plaque behind struts and the neointima.) changes by IVUS. A total of 313 patients were included. Comparison-at-6-month follow-up: All devices induced an increase in the total plaque area. The largest increase occurred with Vision and Taxus stents as compared to other devices [Absorb BVS (1.0 and 1.1) and Xience V], (p=0.0002). Comparison-at-2-year follow-up: Absorb BVS 1.1 had a larger increase from post procedure in total plaque compared to Absorb BVS 1.0, Xience V and Taxus (p=0.0499). However, in Absorb BVS 1.1 total plaque showed a reduction of 2.2% from 1 to 3 years. Specifically, the total plaque in the sequential cohorts of Absorb BVS 1.1 increased 16.2% from baseline to 2 years (Cohort B1) while at 3 years this increase is only 5% compared to baseline (Cohort B2). Local devices affect coronary plaque size differently and it depends on the platform (metallic vs. polymeric) and on whether it is a bare - or drug eluting stent. Coronary scaffolds appear to be a promising alternative to metallic stents since they allow plaque regression at long-term follow-up. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  6. Occurence of Cryptocline taxicola (All. Petr. on needles of Taxus spp. – symptoms and morphological features

    Directory of Open Access Journals (Sweden)

    Ivana Šafránková

    2008-01-01

    Full Text Available In comparison with other European trees species Taxus spp. is not often prone to phytopathological problems. The fungus Cryptocline taxicola (All. Petr was found on needles of cultivars of Yet (T. baccata L., T. cuspidata S. & Z., Taxus × media Rehd. in Brno in the summer and the autumn of 2007. The article attemps to describe the disease symptoms and morphological features. Infected needles and whole shoots turn brown. Fruiting bodies were observed on upper and lower surfaces necrotic and chlorotic needles. Acervuli of the fungus were black, subepidermal, ∅ 160–370 × 90–145 μm, surrounded by brown circles epidermis, and the epidermis ruptures as they brake through. Conidia were smooth-walled and hyaline, without septa, ellipsoid to oval, 10–18 × 4,5–8,4 μm. Conidiophores were hyaline, cylindrical, with phyalides, 12–18 × 2,8–3,4 μm. The fungus forms dark colonies wish greyish aerial mycelium on potato-dextrose agar (PDA.

  7. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Experimental comparison study of the tissue characteristics in transjugular intrahepatic portosystemic shunt and vascular stent

    International Nuclear Information System (INIS)

    Lu Qin; An Yanli; Deng Gang; Fang Wen; Zhu Guangyu; Niu Huanzhang; Yu Hui; Li Guozhao; Teng Gaojun; Wang Zhen; Wei Xiaoying

    2009-01-01

    Objective: To investigate the tissue characteristics within vascular stent and transjugular intrahepatic portosystemic shunt(TIPS) on swine and to provide more information for the understanding and prevention of vascular stent and TIPS restenosis. Methods: Animal models for TIPS were built in 6 swine and vascular stents were implanted in iliac veins simultaneously. 14-28 days after the operation, the 6 swine were killed to remove the TIPS and vascular stent and the pathological examinations were performed on the tissues within the shunt and stent. The similarities and differences of the tissues within the shunt and stent were analyzed with Krttskal Wallis test. Results: Restenosis of TIPS occurred in 4 models and complete occlusion were seen in 2, while all vascular stents were patent and coated with a thin layer of intimal tissue. Electron microscopic results showed that the tissues in restenotic TIPS were loose and with more extra matrix and fibers, and less smooth muscle, fibroblastic and myofibroblastic cells with different and irregular shape and rich secretory granules. The tissues in patent TIPS contained more extra fibers, smooth muscle and fibroblastic cells with normal organelle. The intimal tissues in vascular stent contained more fibers and fibroblasts cells, less smooth muscle cells. On immunohistochemical staining, the tissues in restenotic and patent TIPS as well as the intimal tissues in vascular stent had strong positive expression for anti-SMC- actin-α, the expression were gradually weakened for PCNA, the intimal tissues in vascular stent had a strong positive expression for vimentin, while the expression of the tissues in restenotic and patent TIPS were weakened gradually. For myoglobulin, the tissues in restenotic TIPS had weakly positive expression, the expression in patent TIPS and vascular stent were almost negative. Western blot results for TGF-β showed that the absorbance ratios of the intima tissues in vascular stent, normal vascular

  9. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Chest pain following oesophageal stenting for malignant dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C

    2001-03-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  11. Chest pain following oesophageal stenting for malignant dysphagia

    International Nuclear Information System (INIS)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C.

    2001-01-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  12. Integrating a comprehensive DNA barcode reference library with a global map of yews (Taxus L.) for forensic identification.

    Science.gov (United States)

    Liu, Jie; Milne, Richard I; Möller, Michael; Zhu, Guang-Fu; Ye, Lin-Jiang; Luo, Ya-Huang; Yang, Jun-Bo; Wambulwa, Moses Cheloti; Wang, Chun-Neng; Li, De-Zhu; Gao, Lian-Ming

    2018-05-22

    Rapid and accurate identification of endangered species is a critical component of bio-surveillance and conservation management, and potentially policing illegal trades. However, this is often not possible using traditional taxonomy, especially where only small or pre-processed parts of plants are available. Reliable identification can be achieved via a comprehensive DNA barcode reference library, accompanied by precise distribution data. However, these require extensive sampling at spatial and taxonomic scales, which has rarely been achieved for cosmopolitan taxa. Here we construct a comprehensive DNA barcode reference library, and generate distribution maps using species distribution modeling (SDM), for all 15 Taxus species worldwide. We find that trnL-trnF is the ideal barcode for Taxus: it can distinguish all Taxus species, and in combination with ITS identify hybrids. Among five analysis methods tested, NJ was the most effective. Among 4151 individuals screened for trnL-trnF, 73 haplotypes were detected, all species-specific and some population private. Taxonomical, geographical and genetic dimensions of sampling strategy were all found to affect the comprehensiveness of the resulting DNA barcode library. Maps from SDM showed that most species had allopatric distributions, except three in the Sino-Himalayan region. Using the barcode library and distribution map data, two unknown forensic samples were identified to species (and in one case, population) level, and another was determined as a putative interspecific hybrid. This integrated species identification system for Taxus can be used for bio-surveillance, conservation management and to monitor and prosecute illegal trade. Similar identification systems are recommended for other IUCN- and -CITES listed taxa. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Intravascular local gene transfer mediated by protein-coated metallic stent.

    Science.gov (United States)

    Yuan, J; Gao, R; Shi, R; Song, L; Tang, J; Li, Y; Tang, C; Meng, L; Yuan, W; Chen, Z

    2001-10-01

    To assess the feasibility, efficiency and selectivity of adenovirus-mediated gene transfer to local arterial wall by protein-coated metallic stent. A replication-defective recombinant adenovirus carrying the Lac Z reporter gene for nuclear-specific beta-galactosidase (Ad-beta gal) was used in this study. The coating for metallic stent was made by immersing it in a gelatin solution containing crosslinker. The coated stents were mounted on a 4.0 or 3.0 mm percutaneous transluminal coronary angioplasty (PTCA) balloon and submersed into a high-titer Ad-beta gal viral stock (2 x 10(10) pfu/ml) for 3 min, and then implanted into the carotid arteries in 4 mini-swines and into the left anterior descending branch of the coronary artery in 2 mini-swines via 8F large lumen guiding catheters. The animals were sacrificed 7 (n = 4), 14 (n = 1) and 21 (n = 1) days after implantation, respectively. The beta-galactosidase expression was assessed by X-gal staining. The results showed that the expression of transgene was detected in all animal. In 1 of carotid artery with an intact intima, the beta-gal expression was limited to endothelial cells. In vessels with denuded endothelium, gene expression was found in the sub-intima, media and adventitia. The transfection efficiency of medial smooth muscle cells was 38.6%. In 2 animals sacrificed 7 days after transfection, a microscopic examination of X-gal-stained samples did not show evidence of transfection in remote organs and arterial segments adjacent to the treated arterial site. Adenovirus-mediated arterial gene transfer to endothelial, smooth muscle cells and adventitia by protein-coated metallic stent is feasible. The transfection efficiency is higher. The coated stent may act as a good carrier of adenovirus-mediated gene transfer and have a potential to prevent restenosis following PTCA.

  14. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    Science.gov (United States)

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  15. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  16. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  17. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  18. Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction

    Science.gov (United States)

    Kim, Jae Yun; Ko, Gyu Bong; Lee, Tae Hoon; Park, Sang-Heum; Lee, Yun Nah; Cho, Young Sin; Jung, Yunho; Chung, Il-Kwun; Choi, Hyun Jong; Cha, Sang-Woo; Moon, Jong Ho; Cho, Young Deok; Kim, Sun-Joo

    2017-01-01

    Background/Aims Controversy still exists regarding the benefits of covered self-expandable metal stents (SEMSs) compared to uncovered SEMSs. We aimed to compare the patency and stent-related adverse events of partially covered SEMSs (PC-SEMSs) and uncovered SEMSs in unresectable malignant distal biliary obstruction. Methods A total of 134 patients who received a PC-SEMS or uncovered SEMS for palliation of unresectable malignant distal biliary obstruction were reviewed retrospectively. The main outcome measures were stent patency, stent-related adverse events, and overall survival. Results The median stent patency was 118 days (range, 3 to 802 days) with PC-SEMSs and 105 days (range, 2 to 485 days) with uncovered SEMSs (p=0.718). The overall endoscopic revision rate due to stent dysfunction was 36.6% (26/71) with PC-SEMSs and 36.5% (23/63) with uncovered SEMSs (p=0.589). Tumor ingrowth was more frequent with uncovered SEMSs (4.2% vs 19.1%, p=0.013), but migration was more frequent with PC-SEMSs (11.2% vs 1.5%, p=0.04). The incidence of stent-related adverse events was 2.8% (2/71) with PC-SEMSs and 9.5% (6/63) with uncovered SEMSs (p=0.224). The median overall survival was 166 days with PC-SEMSs and 168 days with uncovered SEMSs (p=0.189). Conclusions Compared to uncovered SEMSs, PC-SEMSs did not prolong stent patency in unresectable malignant distal biliary obstruction. Stent migration was more frequent with PC-SEMSs. However, tumor ingrowth was less frequent with PC-SEMSs compared to uncovered SEMSs. PMID:28208003

  19. TAXOIDES: METABOLITOS SECUNDARIOS DEL ÁRBOL DEL TEJO (Taxus spp.

    Directory of Open Access Journals (Sweden)

    Hebert J. Barrales-Cureño

    2012-01-01

    Full Text Available El árbol del tejo (Taxus spp. es una gimnosperma dicotiledónea que pertenece a la familia Taxaceae; se distribuye en America, Europa y Asia. Taxus spp. contiene en la corteza y en las hojas, alcaloides diterpénicos conocidos como taxoides. Éstos se caracterizan químicamente por la presencia de un esqueleto de taxano y un anillo de oxetano, tal como el taxol, que es utilizado en el tratamiento del cáncer de ovario, seno, próstata y pulmón; enfermedad que actualmente es una de las principales causas de muerte a nivel mundial. El contenido de taxol es bajo en los árboles, por tanto, es necesario el uso de alternativas biotecnológicas como lo es el cultivo in vitro de tejidos vegetales para incrementar la cantidad de taxoides y preservar el recurso natural. En esta revisión científica se reportan las características químicas de los taxoides, el mecanismo de acción biológico y semisíntesis orgánica del taxol, se detalla también la ruta biosintética de los principales taxoides, así como las principales enzimas involucradas para la obtención de éstos a nivel bioquímico y, finalmente, se indica de manera general la producción de taxoides en cultivos in vitro.

  20. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  1. Climatic factors, genetic structure and phenotypic variation in English yew (Taxus baccata L.)

    OpenAIRE

    Mayol, Maria; Berganzo, Elisa; Burgarella, Concetta; González-Martínez, Santiago C.; Grivet, Delphine; Vendramin, Giovanni G.; Vincenot, Lucie; Riba, Miquel

    2018-01-01

    Influence of climatic factors on genetic structure and phenotypic variation in English yew (Taxus baccata L.) Conference "Adapting to global change in the Mediterranean hotspot" (Seville, 18-20 September 2013) Mediterranean forests constitute long-term reservoirs of biodiversity and adaptive potential. As compared with their central or northern European counterparts, Mediterranean forests are characterized by highly heterogeneous and fragmented environments, ...

  2. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    Science.gov (United States)

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  3. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    Science.gov (United States)

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  5. Bioactive Constituents from an Endophytic Fungus, Penicillium polonicum NFW9, Associated with Taxus fauna.

    Science.gov (United States)

    Fatima, Nighat; Sripisut, Tawanun; Youn, Ui J; Ahmed, Safia; Ul-Haq, Ihsan; Munoz-Acuna, Ulyana; Simmons, Charles J; Qazi, Muneer A; Jadoon, Muniba; Tan, Ghee T; de Blanco, Esperanza J C; Chang, Leng C

    2017-01-01

    Endophytic fungi are being recognized as vital and untapped sources of a variety of structurally novel and unique bioactive secondary metabolites in the field of natural products drug discovery. Herein, this study reports the isolation and characterization of secondary metabolites from an endophytic fungus Penicillium polonicum (NFW9) associated with Taxus fuana. The extracts of the endophytic fungus cultured on potato dextrose agar were purified using several chromatographic techniques. Biological evaluation was performed based on their abilities to inhibit tumor necrosis factor-alpha (TNF-α)-induced nuclear factor-kappa B (NF-κB) and cytotoxicity assays. Bioactivity-directed fractionation of the ethyl acetate extract of a fermentation culture of an endophytic fungus, Penicillium polonicum led to the isolation of a dimeric anthraquinone, (R)- 1,1',3,3',5,5'-hexahydroxy-7,7'-dimethyl[2,2'-bianthracene]-9,9',10,10'-tetraone (1), a steroidal furanoid (-)-wortmannolone (2), along with three other compounds (3-4). Moreover, this is the first report on the isolation of compound 1 from an endophytic fungus. All purified metabolites were characterized by NMR and MS data analyses. The stereo structure of compound 1 was determined by the measurement of specific optical rotation and CD spectrum. The relative stereochemistry of 2 was confirmed by single-crystal X-ray diffraction. Compounds 2-3 showed inhibitory activities in the TNF-α-induced NF-κB assay with IC50 values in the range of 0.47-2.11 µM. Compounds 1, 4 and 5 showed moderate inhibition against NF-κB and cancer cell lines. The endophytic fungus Penicillium polonicum of Taxus fuana is capable of producing biologically active natural compounds. Our results provide a scientific rationale for further chemical investigations into endophyte-producing natural products, drug discovery and development. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  7. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents – A phantom study

    International Nuclear Information System (INIS)

    Bunck, Alexander C.; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C.; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R.

    2012-01-01

    Purpose: 4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. Materials and methods: 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. Results: In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n = 14) than by 2D phase contrast flow imaging (n = 10). Conclusions: 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type

  8. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  9. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  10. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.

    Science.gov (United States)

    Park, Jin Myung; Lee, Sang Hyub; Chung, Kwang Hyun; Jang, Dong Kee; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Min; Paik, Woo Hyun

    2016-12-01

    Bilateral stent-in-stent (SIS) self-expandable metal stent placement is technically challenging for palliation of unresectable malignant hilar obstruction. In the SIS technique, the uniform large cell type biliary stent facilitates contralateral stent deployment through the mesh of the first metallic stent. This study aimed to assess the technical success and clinical effectiveness of this technique with a uniform large cell type biliary stent. Thirty-one patients who underwent bilateral SIS placement using a large cell type stent were reviewed retrospectively. All patients showed malignant hilar obstruction (Bismuth types II, III, IV) with different etiologies. Sixteen (51.6%) patients were male. The mean age of the patients was 67.0+/-14.0 years. Most patients were diagnosed as having hilar cholangiocarcinoma (58.1%) and gallbladder cancer (29.0%). Technical success rate was 83.9%. Success was achieved more frequently in patients without masses obstructing the biliary confluence (MOC) than those with MOC (95.2% vs 60.0%, P=0.03). Functional success rate was 77.4%. Complications occurred in 29.0% of the patients. These tended to occur more frequently in patients with MOC (50.0% vs 19.0%, P=0.11). Median time to recurrent biliary obstruction was 188 days and median survival was 175 days. The large cell type stent can be used efficiently for bilateral SIS placement in malignant hilar obstruction. However, the risk of technical failure increases in patients with MOC, and caution is needed to prevent complications for these patients.

  11. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  12. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  13. Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Benjamin Bondue

    2016-01-01

    Full Text Available Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.

  14. Optimization of Process Parameters of Extraction of Amentoflavone, Quercetin and Ginkgetin from Taxus chinensis Using Supercritical CO2 Plus Co-Solvent

    Directory of Open Access Journals (Sweden)

    Xiao Ruan

    2014-10-01

    Full Text Available The effects of extraction time, temperature, pressure and different concentration of ethanol and their interactions on the yields of amentoflavone, quercetin and ginkgetin extracted from Taxus chinensis by supercritical CO2 were investigated by using a central composite design (CCD. An CCD experimental design with four factors and five levels was used to optimize the extraction parameters. Ultra performance liquid chromatography (UPLC was used to analyze the content of the tree components in the extracts. Experimental results show that the main effects of factors and their interactions are significant on the yields (p < 0.05. The optimal extraction conditions were established for the three compounds: yield of 4.47 mg/g for amentoflavone at 48 °C, 25 MPa, 2.02 h and 78.5% ethanol, 3.73 mg/g for quercetin at 46 °C, 24 MPa, 2.3 h, 82% ethanol and 3.47 mg/g for ginkgetin at 48 °C, 20 MPa, 2.38 h, 82% ethanol, respectively.

  15. Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Hyun; Seong, Chang Kyu; Shin, Tae Beom; Kim, Yong Joo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of); Jung, Gyoo Sik [School of Medicine, Kosin National Univ., Pusan (Korea, Republic of); Park, Byeung Ho [School of Medicine, Donga National Univ., Pusan (Korea, Republic of)

    2002-07-01

    To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who encountered problems, breakage of the olive tip occourred in three, upward displacement of the stent in two, and improper expansion of the distal portion of the stent, unrelated with the obstruction site, in one. The broken olive tip was pushed to the duodenum in two cases and to the peripheral intrahepatic duct in one. Where the stent migrated during withdrawal of its introduction system, an additional stent was inserted. In one case, the migrated stent was positioned near the liver capsule and the drainage catheter could not be removed. Although the number of patients in this study was limited, some difficulties were encountered in withdrawing the stent's introduction system. To prevent the occurrence of this unusual complication, the stent should be appropriately expansile, and shape in the olive tip should be considered.

  16. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  17. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    Science.gov (United States)

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  18. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  19. Forgotten Ureteral Stents: An Avoidable Morbidity

    International Nuclear Information System (INIS)

    Murtaza, B.; Alvi, S.

    2016-01-01

    Objective: To assess the clinical presentation of forgotten ureteral stents and highlight the etiological factors resulting in the retention of these stents. Study Design: Observational study. Place and Duration of Study: Department of Urology, Armed Forces Institute of Urology, Rawalpindi, from January 2010 to Jun 2011. Methodology: Thirty-eight patients, with forgotten ureteral stents, retained for more than 6 months duration, were enrolled. A detailed evaluation was performed, along with the questions regarding the patients' opinion about the ureteral stents. They were specially asked whether they knew about the stents or were they formally informed regarding the stents. Subsequently, the patients were managed according to their clinical condition. Results: The male to female ratio was 2.1:1 aged 23 - 69 years, mean being 40.24 ± 12.59 years. The time of presentation after the ureteral stenting was 7 - 180 months (mean = 28.89 ± 33.435 years). Seven patients (18.4 percentage) reported with chronic kidney disease, including ESRD in two cases. Recurrent UTI was seen in 28 cases (73.6 percentage), calculus formed over the stents in 20 cases (52.6 percentage), and stent fragmented in 5 patients (13.1 percentage). Majority of patients, (n = 23, 60.5 percentage), were not even aware of the placement of these stents while 8 (21.0 percentage) knew but were reluctant about its removal. In 3 cases (7.8 percentage), the relatives knew about the stent but never informed the patients. The stent had been removed in 2 cases (5.2 percentage), but the other broken fragment was missed. One case (2.6 percentage) each had a misconception about the permanent placement of the stents like cardiac stents and regarding degradation of the stents in situ. Conclusion: Forgotten ureteral stents produce clinical features ranging from recurrent UTI to ESRD. This preventable urological complication is primarily due to the unawareness or ignorance of the patients and their relatives

  20. Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era

    Directory of Open Access Journals (Sweden)

    Mehrdad Taherioun

    2014-01-01

    Full Text Available BACKGROUND: Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS: After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group. RESULTS: From 50 patients enrolled in this study 39 (78% had optimal stent deployment and 11 (22% had suboptimal stent deployment. In the suboptimal group 7 (14% had underexpansion, 2 (4% malposition, and 2 (4% had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion. CONCLUSION: Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI may be considered for drug eluting stent (DES implantation in relatively small vessels.   Keywords: Stent, Percutaneous Coronary Intervention, Ultrasound, Post-dilatation 

  1. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    Science.gov (United States)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  2. CYP2C19⁎2 Polymorphism in Chilean Patients with In-Stent Restenosis Development and Controls

    Directory of Open Access Journals (Sweden)

    Jenny Ruedlinger

    2017-01-01

    Full Text Available Clopidogrel is an antiplatelet drug especially used in patients undergoing percutaneous coronary interventions (PCI. Polymorphisms within CYP2C19 can result in important interindividual variations regarding therapeutic efficacy. Therefore, we aimed to evaluate the impact of the CYP2C19⁎2 variant (rs4244285 on in-stent restenosis occurrence in Chilean patients who underwent PCI and received clopidogrel. A total of 77 cases with stenosis >50% in the angioplasty site (62.75 ± 9.8 years, 80.5% males and 86 controls (65.45 ± 9.8 years, 72.1% males were studied. The polymorphism was genotyped using TaqMan® Drug Metabolism Genotyping Assays. Overall, CYP2C19⁎2 allele frequency was 8.3%. Diabetes, chronic lesions, and bare metal stents (BMS were observed more often in cases than in controls (p = 0.05, p = 0.04, and p = 0.02, resp.. Genotypic frequencies did not differ significantly between the groups (p = 0.15. Nonetheless, the mutated allele was observed in a greater proportion in patients without in-stent restenosis (p = 0.055. There was no significant association between the rs4244285 variant and the occurrence of in-stent restenosis after PCI (OR = 0.44; 95% CI: 0.19 to 1.04; p = 0.06. In summary, no association was identified between the CYP2C19⁎2 variant and the development of coronary in-stent restenosis.

  3. Una revisión sobre la producción de taxoides anticancerígenos en cultivos in vitro de callos y células de Taxus spp.

    Directory of Open Access Journals (Sweden)

    Hebert Jair Barrales Cureño

    2013-07-01

    Palabras clave: cáncer, biotecnología, metabolismo secundario, taxol, Taxaceae.  Abstract: The taxoids are polioxigenated diterpenes from the metabolic pathway of the 2-methyl-erythritol 4-phosphate whose biosynthesis is generated in the plastides. The importance of the taxoides including taxol, in the area of human medicine is very valuable due to the use in oncology, drug used against breast, lung and ovarian cancer. The species of trees of Taxus spp. are in danger of extinction due to logging immoderate, to the low reproduction rate, slow growth; therefore, the plant tissue culture in vitro is a biotechnological alternative high-impact and a great help to the knowledge of the production of the taxoides to level in vitro and above all, for the conservation of this valuable natural resource. The objectives of this article are to determine some general information about the geographical distribution of Taxus spp.; chemical characteristics of taxoids, biological mechanism of action of taxol; path of biosynthesis, methods of extraction and analysis of the taxoids and a current review of the production of taxoids in situ and in vitro cultures and cells of Taxus spp.  Key words: cancer, biotechnology, secondary metabolism, taxol, Taxaceae.

  4. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents

    OpenAIRE

    Tambaca, Josip; Canic, Suncica; Kosor, Mate; Fish, R. David; Paniagua, David

    2011-01-01

    The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.

  5. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  6. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  7. In-situ investigation of stress conditions during expansion of bare metal stents and PLLA-coated stents using the XRD sin(2)ψ-technique.

    Science.gov (United States)

    Kowalski, Wolfgang; Dammer, Markus; Bakczewitz, Frank; Schmitz, Klaus-Peter; Grabow, Niels; Kessler, Olaf

    2015-09-01

    Drug eluting stents (DES) consist of platform, coating and drug. The platform often is a balloon-expandable bare metal stent made of the CoCr alloy L-605 or stainless steel 316 L. The function of the coating, typically a permanent polymer, is to hold and release the drug, which should improve therapeutic outcome. Before implantation, DES are compressed (crimped) to allow implantation in the human body. During implantation, DES are expanded by balloon inflation. Crimping, as well as expansion, causes high stresses and high strains locally in the DES struts, as well as in the polymer coating. These stresses and strains are important design criteria of DES. Usually, they are calculated numerically by finite element analysis (FEA), but experimental results for validation are hardly available. In this work, the X-ray diffraction (XRD) sin(2)ψ-technique is applied to in-situ determination of stress conditions of bare metal L-605 stents, and Poly-(L-lactide) (PLLA) coated stents. This provides a realistic characterization of the near-surface stress state and a validation option of the numerical FEA. XRD-results from terminal stent struts of the bare metal stent show an increasing compressive load stress in tangential direction with increasing stent expansion. These findings correlate with numerical FEA results. The PLLA-coating also bears increasing compressive load stress during expansion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Nasolacrimal Stenting: Toward Improving Outcomes with a Simple Modification of the Song Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Miguel, Silvia De; Padilla, Manuel; Perea, Miguel; Rodriguez-Merlo, Rufo; Garcia-Garcia, Lorenzo

    2006-01-01

    The purpose of this study was to evaluate, in a prospective, single-center study, the effectiveness of Song's polyurethane stents, modified 'in-house,' in the percutaneous management of epiphora. Patients (n = 170; age range 18-83, mean = 64; 50 male, 120 female) with severe epiphora had the modified stents inserted (183 eyes/195 stents) to treat unilateral/bilateral and complete/partial obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 119 cases (61%) and chronic dacryocystitis in 76 (39%). The set designed by Song was used in all patients but modified by us such that the extreme end is cone-shaped. The original technique was slightly modified by us and the procedure was conducted on an outpatient basis. The initial technical success rate of stent placement was 97%. Resolution of epiphora was complete in 180 eyes and partial in 3. On follow-up (mean = 18 months; range: 2 days to 24 months), 165 of 195 stents (85%) remained patent. Primary patency rates at follow-up were 86%, 84%, 84%, and 79% in the first 6 months, second and third 6 months, and the present (24 months), respectively. Stents became obstructed in 30 patients, but all but 2 were easily withdrawn and 20 of these patients remained asymptomatic for a mean of 14 months (secondary patency of 67%). Following stent removal, the withdrawn stent was replaced with a new stent in the same intervention on 14 occasions. In another six cases, patency was re-established without the need of a second stent. The procedure is simple and safe, both in stent insertion as well as in mechanical de-blocking and withdrawal when occluded. Success was >80 % in the short term (1-year follow-up). Stenting failure does not preclude other treatment because with the modification that we had introduced, the extreme end of the stent becomes more accessible to mechanical de-blocking, withdrawal, and relocation. The levels of primary and secondary patencies are promising and warrant more

  9. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  10. Experimental absorbable stent permits airway remodeling.

    Science.gov (United States)

    Liu, Kuo-Sheng; Liu, Yun-Hen; Peng, Yi-Jie; Liu, Shih-Jung

    2011-02-01

    Despite metallic and silicone stents being effective in treating various airway lesions, many concerns still remain. A bioresorbable stent that scaffolds the airway lumen and dissolves after the remodeling process is completed has advantages over metallic and silicone stents. We designed and fabricated a new mesh-type bioresorbable stent with a backbone of polycaprolactone (PCL), and evaluated its safety and biocompatibility in a rabbit trachea model. The PCL stent was fabricated by a laboratory-made microinjection molding machine. In vitro mechanical strength of the PCL stents was tested and compared to that of commercial silicone stents. The bioresorbable stents were surgically implanted into the cervical trachea of New Zealand white rabbits (n=6). Animals received bronchoscopic examination at 1, 2, 4, 8, and 12 weeks after surgery. Histological examination was completed to evaluate the biocompatibility of the stents. No animals died during the period of study. Distal stent migration was noted in 1 rabbit. In-stent secretion accumulation was found in 2 rabbits. Histological examination showed intact ciliated epithelium and marked leukocyte infiltration in the submucosa of the stented area at 10 and 28 weeks. Stent degradation was minimal, and the mechanical strength was well preserved at the end of 33 weeks. These preliminary findings showed good safety and biocompatibility of the new PCL stent when used in the airway remodeling. PCL could be a promising bioresorbable material for stent design if prolonged degradation time is required. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. 2-year patient-related versus stent-related outcomes

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Christiansen, Evald Høj

    2012-01-01

    years were further assessed with specific focus on patient-related composite (all death, all MI, or any revascularization) and stent-related composite outcomes (cardiac death, target vessel MI, or symptom-driven target lesion revascularization). A total of 1,390 patients were assigned to receive the EES......, and 1,384 patients were assigned to receive the SES. RESULTS: At 2 years, the composite primary endpoint occurred in 8.3% in the EES group and in 8.7% in the SES group (hazard ratio [HR]: 0.94, 95% confidence interval [CI]: 0.73 to 1.22). The patient-related outcome: 15.0% in the EES group versus 15.......80). CONCLUSIONS: At 2-year follow-up, the EES was found to be noninferior to the SES with regard to both patient-related and stent-related clinical outcomes. (Scandinavian Organization for Randomized Trials With Clinical Outcome IV [SORT OUT IV]; NCT00552877)....

  12. Outcomes of the single-stent versus kissing-stents technique in asymmetric complex aortoiliac bifurcation lesions.

    Science.gov (United States)

    Suh, Yongsung; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2015-07-01

    This study investigated the outcomes of single-stent vs kissing-stents techniques in asymmetric complex aortoiliac bifurcation (ACAB) lesions. We retrospectively investigated 80 consecutive patients (69 males, 66.6 ± 8.7 years) treated with a single stent and 30 patients (26 males, 67.1 ± 7.7 years) treated with kissing stents for ACAB between January 2005 and December 2012 from a single-center cohort. A ACAB lesion was defined as a symptomatic unilateral common iliac artery stenosis (>50%) combined with intermediate stenosis (30%-50%) in the contralateral common iliac artery ostium. The primary end point was the primary patency of the ACAB. The baseline clinical characteristics did not differ significantly between the single-stent and the kissing-stents group. Technical success was achieved in all patients. The single-stent group required fewer stents (1.3 ± 0.5 vs 2.3 ± 0.8; P stent group (3%) required bailout kissing stents because of plaque shift to the contralateral side. The major complication rates were 8% in single-stent vs 13% in the kissing-stent group, which was similar (P = .399). At 3 years, the single-stent and kissing-stents group had similar rates of primary patency (89% vs 87%; P = .916) and target lesion revascularization-free survival (93% vs 87%; P = .462). The single-stent technique in ACAB was safe and showed midterm outcomes comparable with those of kissing stents. Considering the benefits, such as fewer stents, less bilateral femoral access, and the availability of contralateral access for future intervention, the single-stent technique may be an advantageous treatment option in ACAB. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  14. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  15. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.

    Science.gov (United States)

    Shen, Yonghua; Liu, Mingdong; Chen, Min; Li, Yunhong; Lu, Ying; Zou, Xiaoping

    2014-01-01

    Refractory chronic pancreatitis has been proposed as a challenge for endoscopists following routine single plastic stenting. However, data on the efficacy and safety of further endoscopic stenting are still controversial. The current systematic review aimed to assess the efficacy and safety of placement of fully covered self-expandable metal stent (FCSEMS) and multiple plastic stents. Databases including MEDLINE, EMBASE, the Cochrane Library, CBM, CNKI, VIP, and WANFANG Database were used to search relevant trials. Published studies were assessed by using well-defined inclusion and exclusion criteria. The process was independently performed by two investigators. A total of 5 studies provided data of 80 patients. Forest plots and publication bias were not carried out because few studies were relevant and screened studies were all case series. The technical success rate was 100% both in placement of FCSEMS and multiple plastic stents. The functional success rate after placement of FCSEMS was 100%, followed by multiple plastic stents (94.7%). Complications occurred 26.2% after FCSEMS placement, which was not described in detail in multiple plastic stents. The stent migration rate was 8.2% for FCSEMS and 10.5% for multiple plastic stents. Reintervention rate was 9.8% for FCSEMS and 15.8% for multiple plastic stents. Pain improvement rate was 85.2% for FCSEMS and 84.2% for multiple plastic stents. FCSEMS appeared to be no significant difference with multiple plastic stents in treatment of refractory chronic pancreatitis. We need to develop more investigations. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  16. Comparison of Immediate and 2-Year Outcomes between Excimer Laser-Assisted Angioplasty with Spot Stent and Primary Stenting in Intermediate to Long Femoropopliteal Disease

    Directory of Open Access Journals (Sweden)

    Tien-Yu Wu

    2013-01-01

    Full Text Available Background. To compare the clinical outcomes between excimer laser-assisted angioplasty (ELA with spot stent (group A and primary stenting (group B in intermediate to long femoropopliteal disease. Methods. Outcomes of 105 patients totaling 119 legs treated with two different strategies were analyzed retrospectively in a prospectively maintained database. Results. Baseline characteristics were similar in both groups. Better angiographic results and lesser increase of serum C-reactive protein levels (0.60 ± 0.72 versus 2.98 ± 0.97 mg/dL, P<0.001 after the intervention were obtained in Group B. Group A had inferior 1-year outcomes due to higher rate of binary restenosis (67% versus 32%, P=0.001 and lower rate of primary patency (40% versus 58%, P=0.039. Rates of amputation-free survival, target vessel revascularization, assisted primary patency, and stent fracture at 24 months were similar in both groups (80% versus 82%, P=0.979, 65% versus 45%, P=0.11, 78% versus 80%, P=0.75 and 6.3% versus 6.8%, P=0.71, resp.. Conclusion. Greater vascular inflammation after ELA with spot stent resulted in earlier restenosis and inferior 1-year clinical outcomes than primary stenting. This benefit was lost in the primary stenting group at 2 years due to late catch-up restenosis. Active surveillance with prompt intervention was required to maintain the vessel patency.

  17. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  18. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  19. Endotracheal expandable metallic stent placement in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology

    1991-01-01

    Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).

  20. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    Science.gov (United States)

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  1. Experimental study of 103Pd stents for preventing the restenosis of biliary duct

    International Nuclear Information System (INIS)

    Gao Qinyi; Shu Qiang; Lu Xiangdong; Li Yaming; He Guijin; Pei Zhuguo; Xu Shuhe

    2004-01-01

    Objective: To explore the feasibility of preventing biliary duct restenosis with the stent treated with 103 Pd and to elucidate the mechanisms of the inhibition of the smooth muscle cell proliferation and the increase of apoptosis. Methods: The experimental dogs were randomly divided into common-stent group and 103 Pd stent group, each of 6 animals. Pathohistology, cell apoptosis, immunohistochemistry for proliferating cell nuclear antigen (PCNA), the expression of gene p53 by in situs hybridization, the test of the peripheral blood and measurement of radiation of tissue around the stent were studied. Results: The utmost intimal thickness of biliary duct in the 103 Pd stent group was found to be obviously less compared to that in common-stent group after 30 d, the percentages of the stenosis of the biliary duct were (54.73 ± 21.64)% and (17.61 ± 14.52)%, respectively, there was a significant difference between two groups (P 103 Pd stent group, and decreased in the common-stent group; the expression of PCNA of biliary smooth muscle cells of 103 Pd group was weaker compared with that in the common-group. Conclusion: 103 Pd stent may inhibit the proliferation of smooth muscle cells and prevent the restenosis of biliary duct. (authors)

  2. Yews (Taxus) along the Hindu Kush-Himalayan region: exploring the ethnopharmacological relevance among communities of Mongol and Caucasian origins.

    Science.gov (United States)

    Poudel, Ram C; Gao, Lian-Ming; Möller, Michael; Baral, Sushim R; Uprety, Yadav; Liu, Jie; Li, De-Zhu

    2013-05-02

    Three species of yews Taxus contorta Griff., Taxus mairei (Lemée & Lév.) S.Y. Hu ex T.S. Liu and Taxus wallichiana Zucc. distributed in the Hindu Kush-Himalayan (HKH) region have been commercially exploited in recent decades to extract an anticancer chemotherapeutic drug 'Taxol'. Additionally, indigenous people of this region are using yews for several other purposes including gastro-intestinal disorders, respiratory problems, skeletal system disorders, and as edible fruit, fodder, fish poison, traditional veterinary medicine, among others. The study was designed to document and evaluate knowledge concerning uses of yews among indigenous communities of Mongol and Caucasian origins. Ethnobotanical knowledge from 10 major ethnic/caste groups of Mongol and Caucasian origins in the Nepal Himalayas was documented in 2010 and 2011 from 27 sites covering the extant distribution range of the three species of Taxus. A total of 72 key informants (60 men, 12 women), recommended by the majority of people in informal group discussions at each study site, were interviewed to collect information on the importance of yews. This study reports multidimensional uses of yews commonly practiced by different indigenous communities of Nepal and compared those with published uses along the HKH region. The key informants cited a total 45 uses under 21 categories. A greater use diversity and high consensus value for use types were recorded for medicinal uses (gastro-intestinal ailments, cough and cold, skeleto-muscular system problem and others medicinal importance) followed by fruit consumption, household tools, agriculture implements and timber. A decline of yew populations and associated traditional knowledge among the younger generations of indigenous people was found. The present study shows a strong agreement of ethnobotanical knowledge on yews between communities of Mongols and Caucasian origins. Our findings further revealed the potential for additional therapeutic applications in

  3. A comparison of clinical efficacy between covered stent-grafts and bare stents in transjuglar in-trahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Jiang Yongbin; Zhang Xitong; Zhang Wei; Xia Yonghui; Liang Songnian; Xu Ke

    2010-01-01

    Objective: To compare the clinical efficacy between covered stent and uncovered stent in transjuglar in-trahepatic portosystemic shunt (TIPS). Methods: Thirty patients with liver cirrhosis (portal hypertension), who received TIPS, were retrospectively studied. All patients were divided into two groups covered-stent group (n=20) and uncovered-stent group (n=10). For each patient, portal pressure was measured before and after operation, and the patency of shunt was evaluated by color Doppler ultrasound after operation. The mortality, recurrent bleeding rate and incidence of hepatic encephalopathy were analyzed by Fisher exact probability test. Results: The TIPS treatment was successful in all patients, the portal pressure in the covered-stent group reduced from (3.78 ± 0.50)kPa to (2.13 ± 0.44) kPa and that of the uncovered-stent group reduced from (3.67 ± 0.48)kPA TO (2.13 ± 0.35)kPa. Twenty-six cases were postoperatively followed-up (17 cases in covered-stent group, 9 cases in uncovered-stent group). the follow-up period varied from 7 days to 62 months (median follow-up period was 23 months). Thirteen patients died of upper gastrointestinal bleeding and hepatic failure. The difference of mortality between covered-stent group (8/17) and uncovered-stent group (5/17) and the uncovered-stent group (3/9) was not different too (P>0.05). The incidence of hepatic encephalopathy in the covered-stent group (4/17) was not different from that of the uncovered-stent group (2/9) (P>0.05). The patency rates of 6 months and 12 months reached 100% in the covered-stent group, which were higher than those in the uncovered-stent group 77.8% (7/9) and 55.6%(5/9) (P<0.05). Conclusions: The patency rate of shunt at 12 months after TIPS was higher in the covered-stent group than the uncovered-stent group, while the mortality, recurrent bleeding rate and incidence of hepatic encephalopathy were not significantly different between the two groups. (authors)

  4. Doxazosin oral intake therapy to relieve stent - related urinary symptoms and pain: a prospective, randomized, controlled study

    Directory of Open Access Journals (Sweden)

    Long Zhang

    Full Text Available ABSTRACT Objective: To assess the impact of Doxazosin Oral Intake Therapy on urinary symptoms and pain in patients with indwelling ureteral stents Patients and Methods: A total of 239 patients with ureteral stone-related hydronephrosis who underwent a double-J stent insertion after ureteroscopic lithotripsy were enrolled. Patients were randomized to receive doxazosin cotrolled release 4 mg once daily for 4 weeks or matching placebo. Patients completed the brief-form Chinese version Ureteric Stent Symptom Questionnaire (USSQ and quality of life (QoL score 2 weeks and 4 weeks after stent placement and 4 weeks after stent withdrawal. The analgesic use was also recorded during the stenting period. Results: Patients in Doxazosin Oral Intake Therapy group, in the first 2 weeks and second 2 weeks with the stent in situ, expressed significant lower daytime frequency (p=0.028 and p=0.038, nocturia (p=0.021 and p=0.008 and urgency (p=0.012 and p=0.014, respectively. Similarly, flank pain score, QoL score and analgesic use were also significant less in the stenting period. There was no significant difference in scores of urinary symptoms, pain and QoL during the post-stent period between two cohorts. Conclusions: Doxazosin Oral Intake Therapy reduced stent-related urinary symptoms, pain and the negative impact on QoL.

  5. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  6. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  7. Air cholangiography in endoscopic bilateral stent-in-stent placement of metallic stents for malignant hilar biliary obstruction.

    Science.gov (United States)

    Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae

    2016-03-01

    Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.

  8. Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Prote'ge'GPS Stent

    International Nuclear Information System (INIS)

    Lee, Da Un; Kim, Jae Kyu; Jung, Hye Doo; Huh, Tae Wook; Yim, Nam Yeol; Oh, Hyun jun; Choi, Soo Jin Na; Chang, Nam Kyu

    2010-01-01

    To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. Of the 38 patients who underwent treatment with Prote'ge'GPS stenting due to arterial occlusions on the superficial femoral artery, 17 also underwent a clinical analysis. Forty-three stents were inserted in the 17 superficial femoral arteries, ranging between 15 and 50 cm in length, with a mean treated length of 26.4 cm (15-50 cm). A fracture was evaluated by taking a PA and lateral simple radiography, as well as a follow-up evaluation accompanied with a CT angiography, DSA, and a color Doppler sonography. The examination involved the assessment of the difference between bone fractures due to length, placement, and frequency. Fractures occurred in 13 of 43 stents (30.2%). A total of 10 (71.4%) occurred in the upper third, compared to 4 (28.6%) in the lower third of the superficial femoral artery. In addition, 10 stents (71.4%) had a single strut fracture, whereas 4 (28.6%) had multiple strut fractures. A stent fracture occurred more frequently when the stents and lesions were longer (p=0.021, 0.012) and the stents were inserted near the joint. However, there was no significant relationship between stent numbers and the fractures (p=0.126). When the stents were inserted along the popliteal artery, a stent fracture occurred more frequently in the lower third of the artery. The stent fractures did not significantly influence the patency rate of the stented artery (p=0.44) Prote'ge'GPS stents in the superficial femoral artery revealed a considerable number of fractures and the fracture frequency showed a significant relationship with the length of stents and lesions. The closer stent insertion was to the joints, the more frequently fractures occurred. There were no evident significant relationships between the presence of stent fractures and the patency of the stented arteries

  9. Stent fabric fatigue of grafts supported by Z-stents versus ringed stents: an in vitro buckling test.

    Science.gov (United States)

    Lin, Jing; Wang, Lu; Guidoin, Robert; Nutley, Mark; Song, Ge; Zhang, Ze; Du, Jia; Douville, Yvan

    2014-03-01

    Stent-grafts externally fitted with a Z-shaped stents were compared to devices fitted with ringed stents in an in vitro oscillating fatigue machine at 200 cycles per minute and a pressure of 360 mmHg for scheduled durations of up to 1 week. The devices fitted with Z-stents showed a considerably lower endurance limit to buckling compared to the controls. The contact between the apexes of adjacent Z-stents resulted in significant damage to the textile scaffolds and polyester fibers due to the sharp angle of the Z-stents. The ringed stents did not cause any fraying in the textile scaffolds.

  10. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  11. Experimental study of the preventive effect of 1'03Pd stent on in-stent restenosis in rabbit iliac artery

    International Nuclear Information System (INIS)

    Luo Quanyong; Chen Libo; Yuan Zhibin; Lu Hankui; Zhu Ruisen

    2003-01-01

    Objective: To investigate the ability of γ-emitting 103 Pd radioactive stent implantation for preventing in-stent restenosis in iliac artery of rabbits. Methods: Twenty New Zealand white rabbits were divided into six groups on the basis of radioactivity loading [2.22 (n=3), 5.55 (n=4), 9.25 (n=4), 14.8 (n=3), 22.2 (n=3), 33.3 MBq (n=3)]. 103 Pd stent was implanted in one of the two iliac arteries of each rabbit and nonradioactive stent in the contralateral artery. The rabbits were fed with high fat diet. Treatment efficiency was assessed by angiography and quantitative histomorphometry of the stented iliac segments 28 d after the implantation. Results: Quantitative histomorphometry analysis indicated that 103 Pd stents induced a significant reduction in neointimal area and the percentage of stenosis within radioactive stents was lower compared with that in the control stents. Nevertheless, the suppression of neointima formation by 103 Pd stent implantation was not in a dose-dependent manner. Conclusions: Low-dose intravascular brachytherapy via a γ-particle-emitting 103 Pd radioactive stent potently inhibits neointimal hyperplasia and prevents the in-stent restenosis in rabbit iliac artery. 103 Pd stent implantation probably can be employed as a novel means to prevent in-stent restenosis

  12. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  13. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  14. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  15. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  16. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  17. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  18. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  19. Stent

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Stent URL of this page: //medlineplus.gov/ency/article/002303.htm Stent To use the sharing features on this page, please enable JavaScript. A stent is a tiny tube placed into a hollow structure in your ...

  20. Clinical application of hepatic vein percutaneous transluminal angioplasty and stent after stent placement in inferior vena cava

    International Nuclear Information System (INIS)

    Xu Hao; Zu Maoheng; Gu Yuming; Li Guojun; Zhang Qingqiao; Wei Ning; Xu Wei; Liu Hongtao

    2005-01-01

    Objective: To investigate the feasibility and effect of recanalization of hepatic vein with percutaneous transluminal angioplasty (PTA) and stent after stent placement in inferior vena cava (IVC). Methods: Eleven patients with Budd-Chiari syndrome (BCS)were once performed metal stent placement in IVC at other hospital, but ascites was not subsided in 9 patients after the stent placement and occurred again in 2 patients in 3 months after the procedure. PTA and metal stent placement were used to treat the occlusion of the hepatic vein (HV) via stent in IVC. Results: Recanalization of occlusive HV was successful in all 11 patients, and symptoms disappeared or were obviously improved. The mean blood pressure in HV dropped from pre-operation (45.12 ± 1.57) cm H 2 O (1 cm H 2 O=0.098 kPa) to post-operation (17.53 ± 0.68) cm H 2 O (P<0.01). In a period of 4-30 months (mean: 13.6 months) following-up, no patient reoccurred symptoms. Conclusion: Recanalization of HV via stent in IVC is a feasible and effective method for occlusive HV, but it is difficult. (authors)

  1. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  2. Study on the application of big cup membranate stent on restenosis after stenting for carcinoma of esophago cardia

    International Nuclear Information System (INIS)

    Wang Xiuping; Yao Zhongqiang; Liu Jian; Zhang Yan

    2007-01-01

    Objective: To evaluate the clinical value of self-designed big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia. Methods: 12 cases of restenosis after stenting for carcinoma of esophago-cardia were involved in the study. Self-designed big cup membranate stent made by Nanjing Weichuang Company (the length of the cup was 3.5 cm)was placed into the constricted stent under guidance of fluoroscopy. Clinical effect, restenosis, and complications were observed during followed up. Results: All the 12 cases of big cup membranat stent placement went along smoothly without indigitation of the cup of the stent. Follow-up of 1.5-8 months showed that 2 cases developed severe restenosis on the big cup of the stem, resulting in third grade difficult deglutition. Among them, one occurred 1 month after stenting, caused by hyperplasia of large amount of granulation tissue; another occurred 6 months after stenting, caused by growth of tumor tissue. 3 cases developed mild to moderate restenosis, 2.3-7 months (mean: 4.6 months) after stenting, with result of first grade difficult deglutition. The remaining 7 cases (mean 5.6 months follow-up) did not have difficulty during deglutition. Conclusions: Application of big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia can effectively prevent the stent from moving downwards and thus lower down the rate of restenosis, and postpone the occurrence of restenosis. (authors)

  3. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    Science.gov (United States)

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  5. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  6. Analysis of taxines in Taxus plant material and cell cultures by hplc photodiode array and hplc-electrospray mass spectrometry

    NARCIS (Netherlands)

    Theodoridis, G.; Laskaris, G.; Rozendaal, E.L.M.; Verpoorte, R.

    2001-01-01

    A semi-purified Taxus baccata needles extract was analysed by RP-HPLC. More than 18 taxines and cinnamates were detected by photodiode array detection and LC-MS, 10 of them being positively identified. Furthermore, 10-deacetyl baccatin III (paclitaxel's main precursor) and other taxanes were also

  7. Serum Levels of IL-1β, IL-6, TGF-β, and MMP-9 in Patients Undergoing Carotid Artery Stenting and Regulation of MMP-9 in a New In Vitro Model of THP-1 Cells Activated by Stenting

    Directory of Open Access Journals (Sweden)

    Rongrong Zhang

    2015-01-01

    Full Text Available Inflammation plays an important role in the pathophysiological process after carotid artery stenting (CAS. Monocyte is a significant source of inflammatory cytokines in vascular remodeling. Telmisartan could reduce inflammation. In our study, we first found that, after CAS, the serum IL-1β, IL-6, TGF-β, and MMP-9 levels were significantly increased, but only MMP-9 level was elevated no less than 3 months. Second, we established a new in vitro model, where THP-1 monocytes were treated with the supernatants of human umbilical vein endothelial cells (HUVECs that were scratched by pipette tips, which mimics monocytes activated by mechanical injury of stenting. The treatment enhanced THP-1 cell adhesion, migration and invasion ability, and the phosphorylation of ERK1/2 and Elk-1 and MMP-9 expression were significantly increased. THP-1 cells pretreated with PD98095 (ERK1/2 inhibitor attenuated the phosphorylation of ERK1/2 and Elk-1 and upregulation of MMP-9, while pretreatment with telmisartan merely decreased the phosphorylation of Elk-1 and MMP-9 expression. These results suggested that IL-1β, IL-6, TGF-β, and MMP-9 participate in the pathophysiological process after CAS. Our new in vitro model mimics monocytes activated by stenting. MMP-9 expression could be regulated through ERK1/2/Elk-1 pathway, and the protective effects of telmisartan after stenting are partly attributed to its MMP-9 inhibition effects via suppression of Elk-1.

  8. Circumferential Stent Fracture: Novel Detection and Treatment with the Use of StentBoost

    OpenAIRE

    Ramegowda, Raghu T.; Chikkaswamy, Srinivas B.; Bharatha, Ashalatha; Radhakrishna, Jayashree; Krishnanaik, Geetha B.; Nanjappa, Manjunath C.; Panneerselvam, Arunkumar

    2012-01-01

    Circumferential stent fracture is extremely uncommon, and in rare cases, it can cause stent thrombosis. Recognizing stent fracture can be difficult on conventional fluoroscopy because of poor stent radiopacity. We found that StentBoost image acquisition yields improved visibility of stent struts, enabling the identification of stent fracture and the precise positioning of new stents over previously stented segments.

  9. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  10. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  11. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    Science.gov (United States)

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. Combined stent implantation and embolization with liquid 2-polyhydroxyethyl methacrylate for treatment of experimental canine wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Klisch, J.; Zitt, J.; Schumacher, M. [Section of Neuroradiology, University of Freiburg (Germany); Schellhammer, F. [Department of Radiology, University of Cologne, Cologne (Germany); Scheufler, K.M. [Department of Neurosurgery, University of Freiburg (Germany); Pagenstecher, A. [Department of Neuropathology, University of Freiburg, Freiburg (Germany); Nagursky, H. [Department of Oral and Maxillofacial Surgery, University of Freiburg, Freiburg (Germany)

    2002-06-01

    The purpose of the study was the evaluation of 2-polyhydroxyethyl methacrylate (2-P-HEMA) for endovascular liquid embolization of experimental side-wall aneurysms following stent protection in a canine model. The swelling behaviour and polymerization characteristics of 2-P-HEMA in different solutions were investigated in vitro. Different methods for applications were tested in a latex aneurysm model under pulsatile flow conditions. Twenty broad-based carotid side-wall aneurysms were microsurgically produced in five dogs. Four weeks after surgery self-expandable nitinol stents were placed, covering the orifice of the aneurysms. 2-P-HEMA was injected via a microcatheter, which was positioned through the meshwork of the stent. Control angiography was performed immediately after treatment and after 1, 6 and 9 months. In-vivo stent placement succeeded in all but one case. Two aneurysms occluded spontaneously after stent placement. Combined embolization of 17 aneurysms using a stent and 2-P-HEMA was performed. Eleven aneurysms could be primarily completely occluded (65%). A small remaining neck was evident in six aneurysms. Efflux of 2-P-HEMA during the process of embolization was observed in seven aneurysms, due to an excess volume of 2-P-HEMA. The excessive 2-P-HEMA led to significant vessel stenosis in two cases. Two carotid arteries (three treated aneurysms) occluded after 1 month, due to insufficient anticoagulation management. Histological examination of embolized aneurysms revealed no foreign-body or inflammatory reaction. A smooth neo-intimal layer covered the stented vessel segment. Liquid embolization of side-wall aneurysms with 2-P-HEMA is technically feasible. Embolotherapy of aneurysms with liquid agents still has the risk that embolic material will exit even when it is stent-protected. To avoid this problem, stents with smaller strut diameter and/or additional balloon-protection are required. The inert 2-P-HEMA seems to be a promising agent for combining

  13. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  14. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  15. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    Science.gov (United States)

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  16. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  17. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  18. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  19. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  20. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  1. Endovascular thrombectomy for M2 occlusions: comparison between forced arterial suction thrombectomy and stent retriever thrombectomy.

    Science.gov (United States)

    Kim, Yong-Won; Son, Seungnam; Kang, Dong-Hun; Hwang, Yang-Ha; Kim, Yong-Sun

    2017-07-01

    To date there has been no direct comparison of two frequently used endovascular thrombectomy (EVT) methods (forced arterial suction thrombectomy (FAST) and stent retriever thrombectomy) in M2 occlusions. We review our experiences with EVT performed using FAST and stent retriever thrombectomy in such cases. The subjects comprised 41 patients with an M2 occlusion who underwent EVT (25 with FAST, 16 with stent retriever thrombectomy). The patients' data were retrospectively analyzed to evaluate the technical characteristics and angiographic outcome of the two EVT techniques. Thrombolysis In Cerebral Infarction (TICI) grades 2b-3 using the first chosen technique did not differ significantly between the two techniques (FAST 64.0% vs stent retriever thrombectomy 81.2%, p=0.305). Time from groin puncture to reperfusion was significantly shorter for stent retriever thrombectomy (53.0 vs 38.5 min; p=0.045). Distal embolization occurred in three cases (12.0%) in the FAST group and in four (26.7%) in the stent retriever group (p=0.362). However, the two techniques did not differ significantly in the final TICI 2b-3 rate (72.0% vs 87.5%; p=0.441). A frequent angiographic finding regarding the failure of FAST was that the M2 occlusion was located immediately after severe acute angulation between M1 and M2. Stent retriever thrombectomy may provide faster reperfusion than FAST, while the FAST technique might be associated with lower distal embolization and a higher reperfusion rate for the first thrombectomy attempt, but without any significant difference in clinical outcome. When choosing the EVT method for M2 occlusions, consideration of the location of the occlusion and tortuosity between M1 and M2 might be helpful to achieve a better angiographic outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  3. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  4. Stent Thrombosis is the Primary Cause of ST-Segment Elevation Myocardial Infarction following Coronary Stent Implantation

    DEFF Research Database (Denmark)

    Kristensen, Søren Lund; Galløe, Anders M; Thuesen, Leif

    2014-01-01

    Background: The widespread use of coronary stents has exposed a growing population to the risk of stent thrombosis, but the importance in terms of risk of ST-segment elevation myocardial infarctions (STEMIs) remains unclear. Methods: We studied five years follow-up data for 2,098 all-comer patients...... treated with coronary stents in the randomized SORT OUT II trial (mean age 63.6 yrs. 74.8% men). Patients who following stent implantation were readmitted with STEMI were included and each patient was categorized ranging from definite-to ruled-out stent thrombosis according to the Academic Research...... Consortium definitions. Multivariate logistic regression was performed on selected covariates to assess odds ratios (ORs) for definite stent thrombosis. Results: 85 patients (4.1%), mean age 62.7 years, 77.1% men, were admitted with a total of 96 STEMIs, of whom 60 (62.5%) had definite stent thrombosis...

  5. StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

    OpenAIRE

    Cura, Fernando; Albertal, Mariano; Candiello, Alfonsina; Nau, Gerardo; Bonvini, Victor; Tricherri, Hernan; Padilla, Lucio T.; Belardi, Jorge A.

    2013-01-01

    Introduction Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. Methods From December 2010 to December 2011, 38 patients (54 stents) were analyzed using IVUS and StentBoost. Minimal stent diameter and...

  6. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  7. Implante de stent dentro de stent recém-implantado em ponte de veia safena para otimização do resultado angiográfico Stenting a stent in saphenous vein graft to optimize the angiographic result

    Directory of Open Access Journals (Sweden)

    Antonio Esteves Fº

    1998-03-01

    Full Text Available Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty. Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.

  8. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

    Science.gov (United States)

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza; Kassaian, Seyed Ebrahim

    2016-04-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.

  9. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  10. Outcomes of secondary self-expandable metal stents versus surgery after delayed initial palliative stent failure in malignant colorectal obstruction.

    Science.gov (United States)

    Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2013-01-01

    When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.

  11. Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction: a randomized multicenter study.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel

    2015-05-01

    Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS.  Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.

  12. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    Science.gov (United States)

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P stents was rejected. The mean number of ERCPs to achieve resolution

  13. Nitinol Esophageal Stents: New Designs and Clinical Indications

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia; Strohm, Michael; Domschke, Sigurd

    1996-01-01

    Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stent implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven

  14. Comparison of retrievable stents and permanent stents for Budd-Chiari syndrome due to obstructive inferior vena cava.

    Science.gov (United States)

    Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei

    2018-05-30

    To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.

  15. Thrombosis of second-generation drug-eluting stents in real practice results from the multicenter Spanish registry ESTROFA-2 (Estudio Español Sobre Trombosis de Stents Farmacoactivos de Segunda Generacion-2).

    Science.gov (United States)

    de la Torre Hernández, José M; Alfonso, Fernando; Gimeno, Federico; Diarte, Jose A; Lopez-Palop, Ramón; Pérez de Prado, Armando; Rivero, Fernando; Sanchis, Juan; Larman, Mariano; Diaz, Jose F; Elizaga, Jaime; Moreiras, Javier Martín; Gomez Jaume, Alfredo; Hernández, José M; Mauri, Josepa; Recalde, Angel Sánchez; Bullones, Juan A; Rumoroso, Jose R; Del Blanco, Bruno García; Baz, Jose A; Bosa, Francisco; Botas, Javier; Hernández, Felipe

    2010-09-01

    This study sought to evaluate second-generation drug-eluting stent (DES) thrombosis in clinical practice. First-generation DES are associated with a significant incidence of late thrombosis. There is paucity of data regarding real practice late thrombosis incidence and predictors with second-generation DES, zotarolimus-eluting stent (ZES), and everolimus-eluting stents (EES). A prospective, large-scale, non-industry-linked multicenter registry was designed. Complete clinical-procedural data and systematic follow-up of all patients treated with these stents was reported in a dedicated registry supported by the Spanish Working Group on Interventional Cardiology. From 2005 to 2008, 4,768 patients were included in 34 centers: 2,549 treated with ZES, and 2,219 with EES. The cumulative incidence of definite/probable thrombosis for ZES was 1.3% at 1 year and 1.7% at 2 years and for EES 1.4% at 1 year and 1.7% at 2 years (p = 0.8). The increment of definite thrombosis between the first and second year was 0.2% and 0.25%, respectively. In a propensity score analysis, the incidence remained very similar. Ejection fraction (adjusted hazard ratio [HR]: 0.97; 95% confidence interval [CI]: 0.95 to -0.99; p = 0.008), stent diameter (adjusted HR: 0.37; 95% CI: 0.17to 0.81; p = 0.01) and bifurcations (adjusted HR: 2.1; 95% CI: 1.14 to 3.7; p = 0.02) emerged as independent predictors of thrombosis. In the subgroup of patients with bifurcations, the use of ZES was independently associated with a higher thrombosis rate (adjusted HR: 4; 95% CI: 1.1 to 13; p = 0.03). In a real practice setting, the incidence of thrombosis at 2 years with ZES and EES was low and quite similar. The incidence of very late thrombosis resulted lower than was reported in registries of first-generation DES. In the subset of bifurcations, the use of ZES significantly increased the risk of thrombosis. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Prospective Evaluation of Two iStent® Trabecular Stents, One iStent Supra® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes.

    Science.gov (United States)

    Myers, Jonathan S; Masood, Imran; Hornbeak, Dana M; Belda, Jose I; Auffarth, Gerd; Jünemann, Anselm; Giamporcaro, Jane Ellen; Martinez-de-la-Casa, Jose M; Ahmed, Iqbal Ike K; Voskanyan, Lilit; Katz, L Jay

    2018-03-01

    This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1-3 glaucoma medications. Subjects received two iStent ® trabecular micro-bypass stents, one iStent Supra ® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. IOP control was achieved safely with two

  17. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  18. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  19. Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms.

    Science.gov (United States)

    Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young

    2014-09-01

    This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.

  20. Influence of covered stent versus bare stent on long-term efficacy of transjugular intrahepatic portosystemic shunt: a meta-analysis

    Directory of Open Access Journals (Sweden)

    XU Lu

    2016-10-01

    Full Text Available Objective To investigate the long-term postoperative efficacy of transjugular intrahepatic portosystemic shunt (TIPS using polytetrafluoroethylene (PTFE-covered stent or bare stent, and to provide a basis of evidence-based medicine for the selection of stent in TIPS. Methods CBM, Wanfang Data, CNKI, VIP, MEDLINE, and PubMed were searched for controlled trials on TIPS in the treatment of cirrhotic portal hypertension published form 1989 to 2015; the studies which met the inclusion criteria were selected, and quality assessment was performed for these articles. RevMan 5.3 software was used to analyze the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate after TIPS, and funnel plots were used to analyze publication bias. Results A total of 11 studies were included, consisting of 698 patients in PTFE-covered stent group and 1283 patients in bare stent group. The results of the meta-analysis showed that the PTFE-covered stent group showed a significantly lower incidence rate of stent dysfunction than the bare stent group (14.8% vs 47.0%, OR=0.18, 95% CI: 0.13-0.24, P<0.001. There was no significant difference in the incidence rate of hepatic encephalopathy between the two groups (23.5% vs 25.7%, OR=0.88, 95% CI: 0.66-1.17, P=0.37. The PTFE-covered stent group had a significantly higher 1-year survival rate than the bare stent group (76.9% vs 62.7%, OR=2.10, 95% CI: 1.54-2.85, P<0.001. The funnel plots which were plotted based on the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate lacked symmetry, which suggested that a certain degree of publication bias might exist. Conclusion Compared with the bare stent, the PTFE-covered stent can improve stent dysfunction and 1-year survival rate after TIPS, while there is no significant change in the incidence rate of hepatic encephalopathy. Therefore, the PTFE-covered stent has certain advantages over the bare stent in TIPS. In

  1. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  2. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  3. Immunoaffinity chromatography for the sample pretreatment of Taxus plant and cell extracts prior to analysis of taxanes by high-performance liquid chromatography

    NARCIS (Netherlands)

    Theodoridis, G; Haasnoot, W; Schilt, R; Jaziri, M; Diallo, B; Papadoyannis, IN; de Jong, GJ; Cazemier, G.

    2002-01-01

    The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked

  4. Microvascular stent anastomosis using N-fibroin stents: feasibility, ischemia time, and complications.

    Science.gov (United States)

    Smeets, Ralf; Vorwig, Oliver; Wöltje, Michael; Gaudin, Robert; Luebke, Andreas M; Beck-Broichsitter, Benedicta; Rheinnecker, Michael; Heiland, Max; Grupp, Katharina; Gröbe, Alexander; Hanken, Henning

    2016-05-01

    To evaluate a novel microvascular anastomosis technique using N-fibroin stents. Cylinder stents of 1 mm diameter and 5 mm length were fabricated using N-fibroin from silkworms. In 22 rats, aortas were dissected, and the stent was inserted into the two ends of the aorta and fixed using methylmethacrylate. Stent anastomosis was successful in 21 (96%) rats. The mean ischemia time was 7.4 minutes, significantly shorter than the 15.9 minutes in the control group with conventional sutures (P stent anastomosis cases, and marked host rejection was evident at the stent anastomosis sites. Around the stents, thrombi were frequent (52%). Our study demonstrated the basic feasibility of stent anastomosis using N-fibroin stents and reduced ischemia time. However, thrombus formation, frequent and severe abdominal infections, and heavy host rejection remain critical issues. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  6. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  7. New expandable metallic stents: An experimental study in vessels of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng

    1992-01-01

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material

  8. New expandable metallic stents: An experimental study in vessels of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng [Chunbuk National University Medical School, Chunju (Korea, Republic of)

    1992-07-15

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material.

  9. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  10. Risk factors for proximal migration of biliary tube stents.

    Science.gov (United States)

    Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya

    2014-02-07

    To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P stents (P stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. Migration of tube stents within the bile duct is rare but possible, and it is important to determine the risk factors

  11. Stent placement of gastroenteric anastomoses formed by magnetic compression.

    Science.gov (United States)

    Cope, C; Clark, T W; Ginsberg, G; Habecker, P

    1999-01-01

    To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

  12. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  13. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    Science.gov (United States)

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  14. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    Science.gov (United States)

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and

  15. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    International Nuclear Information System (INIS)

    De Cock, Erwin; Sapoval, Marc; Julia, Pierre; Lissovoy, Greg de; Lopes, Sandra

    2013-01-01

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of €6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  16. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    Energy Technology Data Exchange (ETDEWEB)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com [United BioSource Corporation, Peri- and Post-Approval Services (Spain); Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Department of Cardiovascular and Interventional Radiology (France); Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Cardiovascular Surgery Department (France); Lissovoy, Greg de, E-mail: gdelisso@jhsph.edu [Johns Hopkins Bloomberg School of Public Health, Department of Health Policy and Management (United States); Lopes, Sandra, E-mail: Sandra.Lopes@CookMedical.com [Cook Medical, Health Economics and Reimbursement (Denmark)

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  17. Metallic ureteral stents in malignant ureteral obstruction: short-term results and radiological features predicting stent failure in patients with non-urological malignancies.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Wang, Shuo-Meng; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liu, Kao-Lang

    2014-06-01

    To provide short-term result of the metallic ureteral stent in patients with malignant ureteral obstruction and identify radiological findings predicting stent failure. The records of all patients with non-urological malignant diseases who have received metallic ureteral stents from July 2009 to March 2012 for ureteral obstruction were reviewed. Stent failure was detected by clinical symptoms and imaging studies. Survival analysis was used to estimate patency rates and factors predicting stent failure. A total of 74 patients with 130 attempts of stent insertion were included. A total of 113 (86.9 %) stents were inserted successfully and 103 (91.2 %) achieved primary patency. After excluding cases without sufficient imaging data, 94 stents were included in the survival analysis. The median functional duration of the 94 stents was 6.2 months (range 3-476 days). Obstruction in abdominal ureter (p = 0.0279) and lymphatic metastasis around ureter (p = 0.0398) were risk factors for stent failure. The median functional durations of the stents for abdominal and pelvic obstructions were 4.5 months (range 3-263 days) and 6.5 months (range 4-476 days), respectively. The median durations of the stents with and without lymphatic metastasis were 5.3 months (range 4-398 days) and 7.8 months (range 31-476 days), respectively. Metallic ureteral stents are effective and safe in relieving ureteral obstructions resulting from non-urological malignancies, and abdominal ureteral obstruction and lymphatic metastasis around ureter were associated with shorter functional duration.

  18. Drug-eluting stents appear superior to bare metal stents for vein-graft PCI in vessels up to a stent diameter of 4 mm

    Directory of Open Access Journals (Sweden)

    Oliver P. Guttmann

    2016-05-01

    Full Text Available BackgroundResearch trials have shown improved short-term outcome with drug-eluting stents (DES over bare metal stents (BMS in saphenous vein graft (SVG percutaneous coronary intervention (PCI, primarily by reducing target vessel revascularization (TVR for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter.MethodsData were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011. A total of 344 patients had PCI with BMS and 313 with DES. Propensity scores were developed based on 15 observed baseline covariates in a logistic regression model with stent type as the dependent variable. The nearest-neighbour-matching algorithm with Greedy 5-1 Digit Matching was used to produce two patient cohorts of 313 patients each. We assessed major adverse cardiac events (MACE out to a median of 3.3 years (interquartile range: 2.1-4.1. MACE was defined as all-cause mortality, myocardial infarction (MI, TVR and stroke.ResultsThere was a significant difference in MACE between the two groups in favour of DES (17.9% DES vs. 31.2% BMS group; p = 0.0017 over the 5-year follow-up period. MACE was driven by increased TVR in the BMS group. There was no difference in death, MI or stroke. Adjusted Cox analysis confirmed a decreased risk of MACE for DES compared with BMS 0.75 (95% confidence interval (CI 0.52-0.94, with no difference in the hazard of all-cause mortality (hazard ratio: 1.08; 95% CI: 0.77-1.68. However, when looking at stent diameters greater than 4 mm, no difference was seen in MACE rates between BMS and DES.ConclusionsOverall in our cohort of patients who had PCI for SVG disease, DES use resulted in lower MACE rates compared with BMS over a 5-year follow-up period; however, for stent diameters over 4 mm no difference in MACE rates was seen.

  19. Comparative vascular responses three months after paclitaxel and everolimus-eluting stent implantation in streptozotocin-induced diabetic porcine coronary arteries

    Directory of Open Access Journals (Sweden)

    Sheehy Alexander

    2012-06-01

    Full Text Available Abstract Background Diabetes remains a significant risk factor for restenosis/thrombosis following stenting. Although vascular healing responses following drug-eluting stent (DES treatment have been characterized previously in healthy animals, comparative assessments of different DES in a large animal model with isolated features of diabetes remains limited. We aimed to comparatively assess the vascular response to paclitaxel-eluting (PES and everolimus-eluting (EES stents in a porcine coronary model of streptozotocin (STZ-induced type I diabetes. Method Twelve Yucatan swine were induced hyperglycemic with a single STZ dose intravenously to ablate pancreatic β-cells. After two months, each animal received one XIENCE V® (EES and one Taxus Liberte (PES stent, respectively, in each coronary artery. After three months, vascular healing was assessed by angiography and histomorphometry. Comparative in vitro effects of everolimus and paclitaxel (10-5 M–10-12 M after 24 hours on carotid endothelial (EC and smooth muscle (SMC cell viability under hyperglycemic (42 mM conditions were assayed by ELISA. Caspase-3 fluorescent assay was used to quantify caspase-3 activity of EC treated with everolimus or paclitaxel (10-5 M, 10-7 M for 24 hours. Results After 3 months, EES reduced neointimal area (1.60 ± 0.41 mm, p vs. 0.08 ± 0.05, greater medial necrosis grade (0.52 ± 0.26 vs. 0.0 ± 0.0, and persistently elevated fibrin scores (1.60 ± 0.60 vs. 0.63 ± 0.41 with PES compared to EES (p In vitro, paclitaxel significantly increased (p -7 M, while everolimus did not affect EC/SMC apoptosis/necrosis within the dose range tested. In ECs, paclitaxel (10-5 M significantly increased caspase-3 activity (p  Conclusion After 3 months, both DES exhibited signs of delayed healing in a STZ-induced diabetic swine model. PES exhibited greater neointimal area, increased inflammation, greater medial necrosis, and

  20. Risk of Adverse Cardiac and Bleeding Events Following Cardiac and Noncardiac Surgery in Patients With Coronary Stent: How Important Is the Interplay Between Stent Type and Time From Stenting to Surgery?

    Science.gov (United States)

    Saia, Francesco; Belotti, Laura Maria Beatrice; Guastaroba, Paolo; Berardini, Alessandra; Rossini, Roberta; Musumeci, Giuseppe; Tarantini, Giuseppe; Campo, Gianluca; Guiducci, Vincenzo; Tarantino, Fabio; Menozzi, Alberto; Varani, Elisabetta; Santarelli, Andrea; Tondi, Stefano; De Palma, Rossana; Rapezzi, Claudio; Marzocchi, Antonio

    2016-01-01

    Epidemiology and consequences of surgery in patients with coronary stents are not clearly defined, as well as the impact of different stent types in relationship with timing of surgery. Among 39 362 patients with previous coronary stenting enrolled in a multicenter prospective registry and followed for 5 years, 13 128 patients underwent 17 226 surgical procedures. The cumulative incidence of surgery at 30 days, 6 months, 1 year, and 5 years was 3.6%, 9.4%, 14.3%, and 40.0%, respectively, and of cardiac and noncardiac surgery was 0.8%, 2.1%, 2.6%, and 4.0% and 1.3%, 5.1%, 9.1%, and 31.7%, respectively. We assessed the incidence and the predictors of cardiac death, myocardial infarction, and serious bleeding event within 30 days from surgery. Cardiac death occurred in 438 patients (2.5%), myocardial infarction in 256 (1.5%), and serious bleeding event in 1099 (6.4%). Surgery increased 1.58× the risk of cardiac death during follow-up. Along with other risk factors, the interplay between stent type and time from percutaneous coronary intervention to surgery was independently associated with cardiac death/myocardial infarction. In comparison with bare-metal stent implanted >12 months before surgery, old-generation drug-eluting stent was associated with higher risk of events at any time point. Conversely, new-generation drug-eluting stent showed similar safety as bare-metal stent >12 months and between 6 and 12 months and appeared trendly safer between 0 and 6 months. Surgery is frequent in patients with coronary stents and carries a considerable risk of ischemic and bleeding events. Ischemic risk is inversely related with time from percutaneous coronary intervention to surgery and is influenced by stent type. © 2015 American Heart Association, Inc.

  1. MRI-compatible Nb–60Ta–2Zr alloy used for vascular stents: Haemocompatibility and its correlation with protein adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiu-Mei [School of Stomatology, China Medical University, 117 Nanjing North Street, Shenyang 110002 (China); Li, Hui-Zhe; Wang, Shao-Ping [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Huang, Hsun-Miao; Huang, Her-Hsiung [Biomaterials and Electrochemistry Lab, Department of Dentistry, National Yang-Ming University, Taipei City 112, Taiwan (China); Ai, Hong-Jun, E-mail: aih0620@yahoo.com.cn [School of Stomatology, China Medical University, 117 Nanjing North Street, Shenyang 110002 (China); Xu, Jian, E-mail: jianxu@imr.ac.cn [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China)

    2014-09-01

    Nb–60Ta–2Zr is a newly developed MRI-compatible alloy used for vascular stents. In this work, its haemocompatibility was investigated, including platelet adhesion (lactate dehydrogenase activity), platelet activation (P-selectin expression), coagulation and haemolysis. For comparison, parallel assessments for these factors were performed for the niobium, tantalum, 316L stainless steel (316L SS) and L605 Co–Cr alloy (L605). In addition, albumin and fibrinogen were selected to examine the correlation of protein adsorption with platelet adhesion and metal surface properties. The propensity for platelet adhesion and activation on the Nb–60Ta–2Zr alloy was at nearly the same level as that for Nb and Ta but was slightly less than those of 316L SS and L605. The mitigated platelet adhesion and activation of the Nb–60Ta–2Zr alloy is associated with its decreased adsorption of fibrinogen. The Nb–60Ta–2Zr alloy has a longer clotting time and exhibits significantly superior thromboresistance than 316L SS and L605. Moreover, the haemolysis rate of the Nb–60Ta–2Zr alloy satisfies the bio-safety requirement of the ISO 10993–4 standard. The favourable haemocompatiblity of the Nb–60Ta–2Zr alloy provides evidence of its good biocompatibility and of its suitability as a candidate stent material. - Highlights: • The Nb–60Ta–2Zr alloy is less hydrophobic than the 316L SS and L605 alloy. • The Nb–60Ta–2Zr has slightly weak propensity for platelet adhesion and activation. • The Nb–60Ta–2Zr alloy results in a longer clotting time. • Haemolysis of Nb–60Ta–2Zr is slightly lower than that of 316L SS and L605. • The Nb–60Ta–2Zr alloy is a promising MRI-compatible stent material.

  2. Metallic Stents for Tracheobronchial Pathology Treatment

    International Nuclear Information System (INIS)

    Serrano, Carolina; Laborda, Alicia; Lozano, Juan M.; Caballero, Hugo; Sebastián, Antonio; Lopera, Jorge; Gregorio, Miguel Ángel de

    2013-01-01

    Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 ± 1.2 months in patients with malignant lesions and 76.2 ± 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results

  3. Metallic stents for tracheobronchial pathology treatment.

    Science.gov (United States)

    Serrano, Carolina; Laborda, Alicia; Lozano, Juan M; Caballero, Hugo; Sebastián, Antonio; Lopera, Jorge; de Gregorio, Miguel Ángel

    2013-12-01

    To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 ± 1.2 months in patients with malignant lesions and 76.2 ± 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  4. Metallic Stents for Tracheobronchial Pathology Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Carolina, E-mail: carolina.serrano@unizar.es [University of Zaragoza, Surgical Pathology Unit, Animal Pathology Department (Spain); Laborda, Alicia, E-mail: alaborda@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain); Lozano, Juan M., E-mail: juamauloz@gmail.com [Marly Clinic, Radiology Department (Colombia); Caballero, Hugo, E-mail: hugocaballero2007@gmail.com [Marly Clinic, Pulmonology Department (Colombia); Sebastian, Antonio, E-mail: antonio.sebastian@ono.es [Lozano Blesa Clinical University Hospital, Pulmonology Department (Spain); Lopera, Jorge, E-mail: lopera@uthscsa.edu [Health Science Center, Interventional Radiology Deparment (United States); Gregorio, Miguel Angel de, E-mail: mgregori@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain)

    2013-12-15

    Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  5. Crossing Y-stent technique with dual open-cell stents for coiling of wide-necked bifurcation aneurysms.

    Science.gov (United States)

    Ko, Jun Kyeung; Han, In Ho; Cho, Won Ho; Choi, Byung Kwan; Cha, Seung Heon; Choi, Chang Hwa; Lee, Sang Weon; Lee, Tae Hong

    2015-05-01

    Double stenting in a Y-configuration is a promising therapeutic option for wide-necked cerebral aneurysms not amenable to reconstruction with a single stent. We retrospectively evaluated the efficacy and safety of the crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms. By collecting clinical and radiological data we evaluated from January 2007 through December 2013, 20 wide-necked bifurcation aneurysms. Twelve unruptured and eight ruptured aneurysms in 20 patients were treated with crossing Y-stent-assisted coiling. Aneurysm size and neck size ranged from 3.2 to 28.2mm (mean 7.5mm) and from 1.9 to 9.1mm (mean 4.5mm). A Y-configuration was established successfully in all 20 patients. All aneurysms were treated with a pair of Neuroform stents. The immediate angiographic results were total occlusion in 17 aneurysms, residual neck in two, and residual sac in one. Peri-operative morbidity was only 5%. Fifteen of 18 surviving patients underwent follow-up conventional angiography (mean, 10.9 months). The result showed stable occlusion in all 15 aneurysms and asymptomatic in-stent occlusion in one branch artery. At the end of the observation period (mean, 33.5 months), all 12 patients without subarachnoid hemorrhage had excellent clinical outcomes (mRS 0), except one (mRS 2). Of eight patients with subarachnoid hemorrhage, four remained symptom free (mRS 0), while the other four had were dependent or dead (mRS score, 3-6). In this report on 20 patients, crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms showed a good technical safety and favorable clinical and angiographic outcome. Copyright © 2015. Published by Elsevier B.V.

  6. Limited Role for Biliary Stent as Surrogate Fiducial Marker in Pancreatic Cancer: Stent and Intratumoral Fiducials Compared

    Energy Technology Data Exchange (ETDEWEB)

    Horst, Astrid van der, E-mail: a.vanderhorst@amc.uva.nl [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Lens, Eelco; Wognum, Silvia; Jong, Rianne de [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Hooft, Jeanin E. van [Department of Gastroenterology and Hepatology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Tienhoven, Geertjan van; Bel, Arjan [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2014-07-01

    Purpose: Because of low soft-tissue contrast of cone beam computed tomography (CBCT), fiducial markers are often used for radiation therapy patient setup verification. For pancreatic cancer patients, biliary stents have been suggested as surrogate fiducials. Using intratumoral fiducials as standard for tumor position, this study aims to quantify the suitability of biliary stents for measuring interfractional and respiratory-induced position variations of pancreatic tumors. Methods and Materials: Eleven pancreatic cancer patients with intratumoral fiducials and a biliary stent were included in this study. Daily CBCT scans (243 in total) were registered with a reference CT scan, based on bony anatomy, on fiducial markers, and on the biliary stent, respectively. We analyzed the differences in tumor position (ie, markers center-of-mass position) among these 3 registrations. In addition, we measured for 9 patients the magnitude of respiratory-induced motion (MM) of the markers and of the stent on 4-dimensional CT (4DCT) and determined the difference between these 2 magnitudes (ΔMM). Results: The stent indicated tumor position better than bony anatomy in 67% of fractions; the absolute difference between the markers and stent registration was >5 mm in 46% of fractions and >10 mm in 20% of fractions. Large PTV margins (superior-inferior direction, >19 mm) would be needed to account for this interfractional position variability. On 4DCT, we found in superior-inferior direction a mean ΔMM of 0.5 mm (range, –2.6 to 4.2 mm). Conclusions: For respiratory-induced motion, the mean ΔMM is small, but for individual patients the absolute difference can be >4 mm. For interfractional position variations, a stent is, on average, a better surrogate fiducial than bony anatomy, but large PTV margins would still be required. Therefore, intratumoral fiducials are recommended for online setup verification for all pancreatic patients scheduled for radiation therapy, including

  7. All-cause mortality after drug-eluting stent implantation in African-Americans.

    Science.gov (United States)

    Poludasu, Shyam; Cavusoglu, Erdal; Khan, Waqas; Marmur, Jonathan D

    2008-12-01

    Recent studies have questioned the safety of drug-eluting stents because of a higher incidence of late stent thrombosis, raising the possibility that drug-eluting stents may be associated with an increased mortality. The effect of drug-eluting stents on mortality in African-Americans is unknown. We evaluated 628 African-American patients (354 patients treated with drug-eluting stents and 274 patients treated with bare metal stents) between January 2003 and August 2005, using data from our bolus-only platelet glycoprotein IIb/IIIa inhibitor database. The primary end point was all-cause mortality obtained using social security death index. After a mean follow-up of 3+/-0.9 years, the mortality rate in the bare metal stents group was 12.8% compared with 7.1% in the drug-eluting stents group [adjusted P value=0.19; hazard ratio (HR) for bare metal stents group compared with drug-eluting stents group for death=1.4; 95% confidence interval (CI): 0.8-2.4]. In a subgroup analysis, patients presenting with acute coronary syndrome had a higher mortality when treated with bare metal stents compared with drug-eluting stents (17.1 vs. 6.3%, P=0.022; HR=2.2; 95% CI: 1.1-4.4). Patients with chronic kidney disease (all patients with creatinine >1.5 mg/dl) also had a higher mortality with bare metal stents compared with drug-eluting stents (36.7 vs. 20.4%, P=0.044; HR=2.3; 95% CI: 1.02-5.2). Drug-eluting stents seem to be safe in African-Americans and may improve survival in certain subgroups such as patients with acute coronary syndromes and chronic kidney disease.

  8. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  9. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  10. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    Science.gov (United States)

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  11. Effect of oral sirolimus therapy on inflammatory biomarkers following coronary stenting

    Directory of Open Access Journals (Sweden)

    W.C.M. Rosa

    2010-08-01

    Full Text Available We studied the effect of oral sirolimus, administered to prevent and treat in-stent restenosis (ISR, on the variation of serum levels of inflammatory markers following coronary stenting with bare metal stents. The mean age of the patients was 56 ± 13 years, 65% were males and all had clinically manifested ischemia. Serum levels of high sensitivity C-reactive protein (hs-CRP concentration were determined by chemiluminescence and serum levels of all other biomarkers by ELISA. One group of patients at high risk for ISR received a loading oral dose of 15 mg sirolimus and 5 mg daily thereafter for 28 days after stenting (SIR-G. A control group (CONT-G was submitted to stenting without sirolimus therapy. The increase in hs-CRP concentration was highest at 24 h after stenting in both groups. A significant difference between SIR-G and CONT-G was observed at 4 weeks (-1.50 ± 5.0 vs -0.19 ± 0.4, P = 0.008 and lost significance 1 month after sirolimus discontinuation (-1.73 ± 4.3 vs -0.01 ± 0.7, P = 0.0975. A continuous fall in MMP-9 concentration was observed in SIR-G, with the greatest reduction at 4 weeks (-352.9 ± 455 vs +395.2 ± 377, P = 0.0004, while a positive variation was noted 4 weeks after sirolimus discontinuation (227 ± 708 vs 406.2 ± 472.1, P = 0.0958. SIR-G exhibited a higher increase in P-selectin after sirolimus discontinuation at week 8 (46.1 ± 67.9 vs 5.8 ± 23.7, P = 0.0025. These findings suggest that the anti-restenotic actions of systemic sirolimus include anti-proliferative effects and modulation of the inflammatory response with inhibition of adhesion molecule expression.

  12. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

    Science.gov (United States)

    Sedat, Jacques; Chau, Yves; Gaudart, Jean; Sachet, Marina; Beuil, Stephanie; Lonjon, Michel

    2018-02-01

    Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.

  13. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  14. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease: A Meta-Analysis of Individual Patient Data.

    Science.gov (United States)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung

    2016-12-26

    The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  15. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  16. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    Energy Technology Data Exchange (ETDEWEB)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at [Klinikum Klagenfurt, The Department of Diagnostic and Interventional Radiology (Austria); Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de [University Clinics Schleswig-Holstein, The Department of Radiology (Germany); Gschwendtner, Manfred, E-mail: manfred.gschwendtner@elisabethinen.or.at [Elisabethinen Hospital, The Department of Diagnostic and Interventional Radiology (Austria); Mueller-Huelsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, The Department of Diagnostic and Interventional Radiology (Germany); Rand, Thomas, E-mail: thomas.rand@wienkav.at [Hietzing Hospital, The Department of Radiology (Austria); Funovics, Martin, E-mail: martin.funovics@meduniwien.ac.at; Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Rastan, Aljoscha, E-mail: aljoscha.rastan@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Gschwandtner, Michael, E-mail: michael.gschwandtner@meduniwien.ac.at [Medical University Vienna, The Department of Angiology (Austria); Puchner, Stefan, E-mail: stefan.puchner@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); and others

    2015-02-15

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

  17. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    Science.gov (United States)

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  18. Risk Factors for Migration, Fracture, and Dislocation of Pancreatic Stents

    Directory of Open Access Journals (Sweden)

    Yoshiaki Kawaguchi

    2015-01-01

    Full Text Available Aim. To analyze the risk factors for pancreatic stent migration, dislocation, and fracture in chronic pancreatitis patients with pancreatic strictures. Materials and Methods. Endoscopic stent placements (total 386 times were performed in 99 chronic pancreatitis patients with pancreatic duct stenosis at our institution between April 2006 and June 2014. We retrospectively examined the frequency of stent migration, dislocation, and fracture and analyzed the patient factors and stent factors. We also investigated the retrieval methods for migrated and fractured stents and their success rates. Results. The frequencies of stent migration, dislocation, and fracture were 1.5% (5/396, 0.8% (3/396, and 1.2% (4/396, respectively. No significant differences in the rates of migration, dislocation, or fracture were noted on the patient factors (etiology, cases undergoing endoscopic pancreatic sphincterotomy, location of pancreatic duct stenosis, existence of pancreatic stone, and approach from the main or minor papilla and stent factors (duration of stent placement, numbers of stent placements, stent shape, diameter, and length. Stent retrieval was successful in all cases of migration. In cases of fractured stents, retrieval was successful in 2 of 4 cases. Conclusion. Stent migration, fracture, and dislocation are relatively rare, but possible complications. A good understanding of retrieval techniques is necessary.

  19. In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases.

    Science.gov (United States)

    Chalouhi, Nohra; Drueding, Ross; Starke, Robert M; Jabbour, Pascal; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert; Tjoumakaris, Stavropoula

    2013-03-01

    Neuroform and Enterprise are widely used self-expanding stents designed to treat wide-necked intracranial aneurysms. To assess the incidence, clinical significance, predictors, and outcomes of in-stent stenosis (ISS). Angiographic studies and hospital records were retrospectively reviewed for 435 patients treated between 2005 and 2011 in our institution. A multivariable regression analysis was conducted to determine the predictors of ISS. The Neuroform stent was used in 264 patients (60.7%) and the Enterprise in 171 patients (39.3%). A total of 11 patients (2.5%) demonstrated some degree of ISS during the follow-up period at a mean time point of 4.2 months (range, 2-12 months). The stenosis was mild ( 75%) in 1 patient (0.2%). No patients were symptomatic or required further intervention. There was complete ISS resolution in 2 patients, partial resolution in 2 patients, and no change in 5 patients on follow-up angiography. Patients developing ISS were significantly younger than those without ISS (40.3 vs. 54.9 years; P stent (P = .6). In multivariable analysis, younger patient age (odds ratio = 0.92; P = .008), carotid ophthalmic aneurysm location (odds ratio = 7.7; P =0.01), and carotid terminus aneurysm location (odds ratio = 8.1; P = .009) were strong independent predictors of ISS. The type of stent was not a predictive factor. Neuroform and Enterprise ISS is an uncommon, often transient, and clinically benign complication. Younger patients and those harboring anterior circulation aneurysms located at ophthalmic and carotid terminus locations are more likely to develop ISS.

  20. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  1. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  2. Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Michael Köhler

    2011-01-01

    Full Text Available Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy were examined in a vessel phantom. All stents were imaged in axial orientation with standard parameters. Image reconstructions were obtained with four different convolution kernels. To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density and noise were measured. Results. The mean percentage of the visible stent lumen diameter from the nominal stent diameter was 74.5% ± 5.7 for the medium-sharp kernel, 72.8% ± 6.4 for the medium, 70.8% ± 6.4 for the medium-smooth and 67.6% ± 6.6 for the smooth kernel. Mean values of lumen attenuation were 299.7HU ± 127 (medium-sharp, 273.9HU ± 68 (medium, 270.7HU ± 53 (medium-smooth and 265.8HU ± 43. Mean image noise was: 54.6 ± 6.3, 20.5 ± 1.7, 16.3 ± 1.7, 14.0 ± 2 respectively. Conclusion. Visible stent lumen diameter varies depending on stent type and scan parameters. Lumen diameter visibility increases with the sharpness of the reconstruction kernel. Smoother kernels provide more realistic density measurements inside the stent lumen and less image noise.

  3. The study of metal stents for effect to the radiation therapy

    International Nuclear Information System (INIS)

    Gao Li; Feng Ningyuan; Zhai Renyou; Yang Weizhi; Xu Guozhen; Wang Yafei

    2001-01-01

    Objective: To confirm whether the metal stents affect the radiation beam. Methods: The transmission factors from the national self-expanding esophagus stent, stainless self-expanding bile duct stent, and balloon-expanded vascular stent was supervised under 192 Ir irradiation in the air. Results: The transmission factors from the 3 kinds of metal stents were 0.993, 0.988, and 0.997, which meant that the attenuation of the stents to the radiation was 0.7%, 1.2%, and 0.3%, respectively (mean: 0.7%). Conclusion: The effect of the metal stents to the radiation was less than 1.2% and that meant there was no clinical significant effect on the patients irradiated following stent implantation or to perform the intra-stents brachytherapy

  4. Flexibility and trackability of laser cut coronary stent systems.

    Science.gov (United States)

    Szabadíts, Péter; Puskás, Zsolt; Dobránszky, János

    2009-01-01

    Coronary stents are the most important supports in present day cardiology. Flexibility and trackability are two basic features of stents. In this paper, four different balloon-expandable coronary stent systems were investigated mechanically in order to compare their suitability. The coronary stent systems were assessed by measurements of stent flexibility as well as by comparison of forces during simulated stenting in a self-investigated coronary vessel model. The stents were cut by laser from a single tube of 316L stainless steel or L-605 (CoCr) cobalt chromium alloy. The one-and four-point bending tests were carried out to evaluate the stent flexibility E x I (Nmm(2)), under displacement control in crimped and expanded configurations. The flexibility of stents would be rather dependent on the design than on raw material. In general a more flexible stent needs lower tracking force during the implantation. The L-605 raw material stents need lower track force to pass through in the vessel model than the 316L raw material stents. The sort and long stents passed through the curved vessel model in different ways. The long stents nestled to the vessel wall at the outer arc and bent, while the short stents did not bend in the curve, only the delivery systems bent.

  5. Association between silent embolic cerebral infarction and continuous increase of P2Y12 reaction units after neurovascular stenting.

    Science.gov (United States)

    Kim, Bum Joon; Kwon, Joo Y; Jung, Jin-Man; Lee, Deok Hee; Kang, Dong-Wha; Kim, Jong S; Kwon, Sun U

    2014-10-01

    Endovascular procedures are one of the important treatment options for steno-occlusive arteries in ischemic stroke patients. However, embolic complications after such procedures are always a concern. The authors investigated the association between serial change of residual platelet reactivity and silent embolic cerebral infarction (SECI) after endovascular treatment. Ischemic stroke patients undergoing stenting of intra- or extracranial arteries were recruited prospectively. Residual platelet reactivity, represented by aspirin reaction units (ARUs) and P2Y12 reaction units (PRUs), was measured serially (6 hours before, immediately after, and 24 hours after the procedure). A loading dosage of aspirin (500 mg) and/or clopidogrel (300 mg) was given 24 hours before the procedure to patients naïve to antiplatelet agents, whereas the usual dosage (aspirin 100 mg and clopidogrel 75 mg) was continued for patients who had previously been taking these agents for more than a week. Diffusion-weighted MRI was performed before and 24 hours after the procedure to detect new SECIs. Clinical characteristics, baseline ARU and PRU values, and the change in ARU and PRU values after stenting were compared between patients with and without SECIs. Among 69 consecutive patients who underwent neurovascular stent insertion, 41 patients (59.4%) had poststenting SECIs. The lesion was located only at the vascular territory of the stented vessel in 21 patients (51.2%), outside the stented vessel territory in 8 patients (19.5%), and both inside and outside in 12 patients (29.3%). The occurrence of SECIs was not associated with the baseline ARU or PRU value, but was associated with PRU increase after stenting (36 ± 73 vs -12 ± 59, p = 0.007), deployment of a longer stent (31.1 ± 16.5 mm vs 21.8 ± 9.9 mm, p = 0.01), and stent insertion in extracranial arteries (78.1% vs 45.2%, p = 0.008). Stent length (OR 1.066, p = 0.01) and PRU change (OR 1.009, p = 0.04) were independently associated with

  6. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  7. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    1991-05-15

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction.

  8. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun

    1991-01-01

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction

  9. Results of a randomized clinical trial of external beam radiation to prevent restenosis after superficial femoral artery stenting.

    Science.gov (United States)

    Therasse, Eric; Donath, David; Elkouri, Stéphane; Lespérance, Jacques; Giroux, Marie-France; Oliva, Vincent L; Guertin, Marie-Claude; Bouchard, Louis; Perreault, Pierre; Gilbert, Patrick; Soulez, Gilles

    2016-06-01

    The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Li Gang; Li Haiqing; Wang Lin

    2005-01-01

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  11. In-hospital management and outcome of patients on warfarin undergoing coronary stent implantation: results of the multicenter, prospective WARfarin and coronary STENTing (WAR-STENT) registry.

    Science.gov (United States)

    Rubboli, Andrea; Sciahbasi, Alessandro; Briguori, Carlo; Saia, Francesco; Palmieri, Cataldo; Moroni, Luigi Andrea; Calabrò, Paolo; Leone, Antonio Maria; Franco, Nicoletta; Valgimigli, Marco; Varani, Elisabetta; Santi, Michela; Pasqualini, Paola; Capecchi, Alessandro; Piccalò, Giacomo; Margheri, Massimo; di Pasquale, Giuseppe; Galvani, Marcello; Bolognese, Leonardo; Gonzini, Lucio; Maggioni, Aldo Pietro

    2013-04-01

    The in-hospital management of patients on warfarin undergoing coronary stent implantation (PCI-S) is variable, and the in-hospital outcome incompletely defined. To determine the adherence to the current recommendations, and the incidence of adverse events, we carried out the prospective, multicenter, observational WARfarin and coronary STENTing (WAR-STENT) registry (ClinicalTrials.gov identifier NCT00722319). All consecutive patients on warfarin undergoing PCI-S at 37 Italian centers were enrolled and followed for 12 months. Outcome measures were: major adverse cardiovascular events (MACE), including cardiovascular death, non-fatal myocardial infarction, need for urgent revascularization, stroke, and venous thromboembolism, and major and minor bleeding. In this paper, we report the in-hospital findings. Out of the 411 patients enrolled, 92% were at non-low (ie, moderate or high) thromboembolic risk. The radial approach and bare-metal stents were used in 61% and 60% of cases, respectively. Drug-eluting stents were essentially reserved to patients with diabetes, which in turn, significantly predicted the implantation of drug-eluting stents (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.29-3.17; P=.002). The in-hospital MACE and major bleeding rates were 2.7% and 2.1%, respectively. At discharge, triple therapy (TT) of warfarin, aspirin, and clopidogrel was prescribed to 76% of patients. Prescription of TT was significantly more frequent in the non-low thromboembolic risk group. Non-low thromboembolic risk, in turn, was a significant predictor of TT prescription (OR, 11.2; 95% CI, 4.83-26.3; P<.0001). In conclusion, real-world warfarin patients undergoing PCI-S are largely managed according to the current recommendations. As a consequence, the risk of in-hospital MACE and major bleedings appears limited and acceptable.

  12. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  13. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model.

    Science.gov (United States)

    Park, Hong Suk; Choo, In Wook; Seo, Soowon; Hyun, Dongho; Lim, Sooyoun; Kim, Jae J; Hong, Saet-Byul; Min, Byung-Hoon; Do, Young Soo; Choo, Sung Wook; Shin, Sung Wook; Park, Kwang Bo; Cho, Sung Ki

    2015-01-01

    Migration of stents is one of the most common adverse events in covered stent placement in GI tract obstruction. To compare physical property and migration rates in a canine colon obstruction model among a novel stent and conventional stents. Comparative physical test and animal study. Medical device testing laboratory and animal laboratory. Mongrel dogs (N=26). Surgical colon obstruction followed by placement of a novel (n=13) or conventional (n=13) stent. Physical properties, migration, and adverse events. The novel stent showed better flexibility, as in a physical test of longitudinal compressibility and axial force, than did conventional stents, and it withstood the fatigue test for 10 days. In terms of radial force and tensile strength, the novel stent showed the same or better results than conventional stents. In a canine colon obstruction model, the migration rate of a novel stent was significantly lower than that of a conventional stent (2/13, 15.4% vs 8/13, 61.5%; P=.008). Animal study of limited size. The novel, ring-connected stent is more flexible and more resistant to migration than the conventional stents. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. The influence of stents on microbial colonization of the airway in children after slide tracheoplasty: a 14-year single-center experience.

    Science.gov (United States)

    Rijnberg, Friso M; Butler, Colin R; Speggiorin, Simone; Fierens, Anja; Wallis, Colin; Nouraei, Reza; McLaren, Clare A; Roebuck, Derek J; Hewitt, Richard; Elliott, Martin J

    2015-01-01

    This study describes the microbial colonization profile of the airway in children after slide tracheoplasty (STP) with and without stents, and compares colonization to children undergoing cardiothoracic surgical procedures without airway related disease. A 14-year retrospective single case note review was performed on patients undergoing STP and stent insertion. Nose and throat (NT) and bronchoalveolar lavage (BAL) specimens were analyzed for microbial profile and expressed as cumulative mean microorganisms per patient (MMP). Forty-three patients (median age ± SD 15.02 ± 31.76 months) underwent STP and 141 patients underwent cardiothoracic but no airway surgery (median age ± SD 31.7 ± 47.2 months). Sixteen patients required a stent after STP. One-hundred seventy-two positive microbial specimens were identified. The predominant 6 microorganisms were (1) Staphylococcus aureus; (2) Pseudomonas aeruginosa; (3) Haemophilus influenzae not type B; (4) Coliforms; (5) Streptococcus pneumoniae; and (6) Candida Albicans, and accounted for 128 (74%) of all positive specimens found. Children with stents had more MMP compared to children without stents after STP [4.06 ± 2.38 and 2.04 ± 2.24 MMP (P stents had more microbial colonization of their lower respiratory tract compared to their upper respiratory tract (3.36 ± 2.02 and 1.36 ± 0.93 MMP (P stents compared to children without stents after STP [0.5 and 0.15 MMP (P stents to be a significant risk factor for microbial colonization of the airway in children. More specifically airway stents appear to increase colonization in the distal airway, which appears unrelated to that of the upper respiratory tract. © 2014 Wiley Periodicals, Inc.

  15. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  16. Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents

    International Nuclear Information System (INIS)

    Kirisits, Christian; Wexberg, Paul; Gottsauner-Wolf, Michael; Pokrajac, Boris; Ortmann, Elisabeth; Aiginger, Hannes; Glogar, Dietmar; Poetter, Richard

    2001-01-01

    Background and purpose: Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. Materials and methods: Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean±SD. Results: The mean activity of the stents was 438±140 kBq at implantation. The mean reference dose was 111±35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68±20 Gy. On average, DV90 and DV10 were 33±9 Gy and 117±41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55±17 Gy, and DV 90 and DV 10 were 6.4±2.4 Gy and 107±36 Gy, respectively. Conclusions: The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy

  17. French experience of silicone tracheobronchial stenting in children.

    Science.gov (United States)

    Fayon, Michael; Donato, Lionel; de Blic, Jacques; Labbé, André; Becmeur, François; Mely, Laurent; Dutau, Hervé

    2005-01-01

    Silicone stents were inserted into the trachea or left main-stem bronchus in 14 children aged 2-69 months (median, 7 months). Indications were as follows: tracheomalacia or airway kinking (7 cases), vascular compression (5 cases), and surgically corrected congenital tracheal stenoses (2 cases). The best results were obtained in tracheomalacia. Overall, 6 cases out of 14 (43%) were considered successful, with a stent placement duration of 3-15 months (median, 7 months). Two cases were considered a technical success, although they were clinical failures. Five cases were considered failures primarily due to stent migration. A retrospective analysis of failures suggests that most of these could have been avoided by the use of larger stents. One patient died of stent obstruction. No wall erosion was observed, and the development of granulation tissue was infrequent. Endoscopic removal of the prostheses was uneventful. The biocompatibility of silicone stents appears to be better than what is reported for metal ones, although the stability of the former is less satisfactory. The present study shows the feasibility of silicone stent placement in infants. These stents should be considered as a possible therapeutic option in certain types of childhood airway disorders, although further studies are required.

  18. Vorinostat-eluting poly(DL-lactide-co-glycolide nanofiber-coated stent for inhibition of cholangiocarcinoma cells

    Directory of Open Access Journals (Sweden)

    Kwak TW

    2017-10-01

    Full Text Available Tae Won Kwak,1,* Hye Lim Lee,2,* Yeon Hui Song,2 Chan Kim,3 Jungsoo Kim,2 Sol-Ji Seo,2 Young-Il Jeong,2 Dae Hwan Kang2,4 1Medical Convergence Textile Center, Gyeongbuk, Republic of Korea; 2Biomedical Research Institute, Pusan National University Hospital, Pusan, Republic of Korea; 3Amogreentech Co. Ltd. Gyeonggi-do, Republic of Korea; 4Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongnam, Republic of Korea *These authors contributed equally to this work Purpose: The aim of this study was to fabricate a vorinostat (Zolinza™-eluting nanofiber membrane-coated gastrointestinal (GI stent and to study its antitumor activity against cholangiocarcinoma (CCA cells in vitro and in vivo. Methods: Vorinostat and poly(DL-lactide-co-glycolide dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. Results: A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1·3·4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Conclusion: Vorinostat-eluting nanofiber membranes showed significant antitumor

  19. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko; Kuwahara, Sadatoshi; Mehta, Dhruv

    2009-01-01

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution

  20. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul [Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2010-03-15

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 +- 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 +- 2.6 months. The mean period of primary stent patency was 16.4 +- 2.6 months in the 26 mm stent group, and significantly higher than 5.4 +- 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  1. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    International Nuclear Information System (INIS)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul; Kim, Sam Soo

    2010-01-01

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 ± 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 ± 2.6 months. The mean period of primary stent patency was 16.4 ± 2.6 months in the 26 mm stent group, and significantly higher than 5.4 ± 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  2. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Korea University Guro Hospital, Seoul (Korea, Republic of); Oh, Joo Hyeogn; Park, Young Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of); Song, Ho Young [University of Ulsan, College of Medicine, Seoul (Korea, Republic of); Park, Sang Joon [Hallym University, College of Medicine, Seoul (Korea, Republic of); Yuk, Sun Hong [Hannam University, Daejeon (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension.

  3. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  4. Stent Thrombosis in Drug-Eluting or Bare-Metal Stents in Patients Receiving Dual Antiplatelet Therapy.

    Science.gov (United States)

    Kereiakes, Dean J; Yeh, Robert W; Massaro, Joseph M; Driscoll-Shempp, Priscilla; Cutlip, Donald E; Steg, P Gabriel; Gershlick, Anthony H; Darius, Harald; Meredith, Ian T; Ormiston, John; Tanguay, Jean-François; Windecker, Stephan; Garratt, Kirk N; Kandzari, David E; Lee, David P; Simon, Daniel I; Iancu, Adrian Corneliu; Trebacz, Jaroslaw; Mauri, Laura

    2015-10-01

    This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  6. Malignant biliary obstruction: percutaneous use of self-expandable stents

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.; Nijs, H. G.; Zonderland, H. M.; Terpstra, O. T.; van Blankenstein, M.; Schütte, H. E.

    1991-01-01

    A total of 83 self-expandable metallic stents were placed percutaneously in 69 patients for palliation of malignant biliary obstruction. Stent diameter was 1 cm; length, 3.5-10.5 cm. Of the 41 patients with common bile duct obstruction, 27 died 0.2-12 months (median, 3.2 months) after stent

  7. Experimental study of different nickel-titanium memory tracheal stents in dogs

    International Nuclear Information System (INIS)

    Lang Xu; He Nengshu; Fan Hailun

    2009-01-01

    Objective: Since membrane -covered metal tracheal stent was applied successfully to treat the airway stenosis, it has been widely used and obtained satisfactory result during the past years. The purpose of our study was provide theoretical rational for treatment with membrane-covered tracheal stent by using animal experiment. Methods: The nickel- titanium memory stents of 22 mm in diameter and 6 cm in length were deployed in 18 dogs. The dogs were grouped into full- length membrane-covered group (n=6), partial-length membrane-covered group (membrane was covered for 4 cm in the medial part of the stent, n=6), and naked stent group (n=6). After the stent placement dysphagia or dysphonia was monitored daily. Twenty-four weeks later, the dogs were executed. Speiments were taken from the cephalic, medial, and caudal trachea under the stent. HE stain and proliferating cell nuclear antigen (PCNA) were evaluated. Results: After the stent placement, no dyspnea, dysphagia or dysphonia but cough was present in each dog. There was no significant difference in symptom between the three groups. Inflammation reaction, metaplasia from low columnar epithelium to spuamous epithelium, and mild granulation tissue hyperplasia in the underlying mucosa were present in each group. However, fibrosis and tracheal straitness were present only in the non-membrane-covered area, but not in the membrane-covered area. More PCNA expression was observed in the non-membrane -covered area than in the membrane-covered area. Conclusion: Both membrane-covered and non-membrane-covered stents can cause similar symptoms. However, the membrane -covered tracheal stent has good biological compatibility and would not induce tracheal straitness. The non-membrane -covered tracheal stent could induce a severe pathologic reaction and tracheal straitness. (authors)

  8. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    Science.gov (United States)

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  9. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry)

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Jensen, Lisette Okkels; Maeng, Michael

    2009-01-01

    OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST...... databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1...

  10. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  11. Treatment of Post-Stent Gastroesophageal Reflux by Anti-Reflux Z-Stent

    International Nuclear Information System (INIS)

    Davies, Roger Philip; Kew, Jacqueline; Byrne, Peter D.

    2000-01-01

    Severe symptoms of heartburn and retrosternal pain consistent with gastro-esophageal reflux (GER) developed in a patient following placement of a conventional self-expanding 16-24-mm-diameter x 12-cm-long esophageal stent across the gastroesophageal junction to treat an obstructing esophageal carcinoma. A second 18-mm-diameter x 10-cm-long esophageal stent with anti-reflux valve was deployed coaxially and reduced symptomatic GER immediately. Improvement was sustained at 4-month follow-up. An anti-reflux stent can be successfully used to treat significant symptomatic GER after conventional stenting

  12. Semi-Automatic Electronic Stent Register: a novel approach to preventing ureteric stents lost to follow up.

    Science.gov (United States)

    Macneil, James W H; Michail, Peter; Patel, Manish I; Ashbourne, Julie; Bariol, Simon V; Ende, David A; Hossack, Tania A; Lau, Howard; Wang, Audrey C; Brooks, Andrew J

    2017-10-01

    Ureteric stents are indispensable tools in modern urology; however, the risk of them not being followed-up once inserted poses medical and medico-legal risks. Stent registers are a common solution to mitigate this risk; however, manual registers are logistically challenging, especially for busy units. Western Sydney Local Health District developed a novel Semi-Automatic Electronic Stent Register (SAESR) utilizing billing information to track stent insertions. To determine the utility of this system, an audit was conducted comparing the 6 months before the introduction of the register to the first 6 months of the register. In the first 6 months of the register, 457 stents were inserted. At the time of writing, two of these are severely delayed for removal, representing a rate of 0.4%. In the 6 months immediately preceding the introduction of the register, 497 stents were inserted, and six were either missed completely or severely delayed in their removal, representing a rate of 1.2%. A non-inferiority analysis found this to be no worse than the results achieved before the introduction of the register. The SAESR allowed us to improve upon our better than expected rate of stents lost to follow up or severely delayed. We demonstrated non-inferiority in the rate of lost or severely delayed stents, and a number of other advantages including savings in personnel costs. The semi-automatic register represents an effective way of reducing the risk associated with a common urological procedure. We believe that this methodology could be implemented elsewhere. © 2017 Royal Australasian College of Surgeons.

  13. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Factors Associated with In-stent Restenosis in Patients Following Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Dedi Wihanda

    2015-07-01

    Full Text Available Aim: to determine factors associated with In-Stent Restenosis (ISR in patients following Percutaneous Coronary Intervention (PCI. Methods: a retrospective cross-sectional study was conducted using secondary information from medical records of post-PCI patients who underwent follow-up of angiography PCI between January 2009 and March 2014 at The Integrated Cardiovascular Service Unit, Cipto Mangunkusumo Hospital, Jakarta. Angiographic ISR was defined when the diameter of stenosis ≥50% at follow-up angiography including the diameter inside the stent and diameter with five-mm protrusion out of the proximal and distal ends of the stent. Results: there were 289 subjects including 133 subjects with and 156 subjects without ISR. The incidence of ISR in patients using of bare-metal stent (BMS and drug-eluting stent (DES were 61.3% and 40.7%, respectively. Factors associated with ISR are stent-type (OR=4.83, 95% CI 2.51-9.30, stent length (OR=3.71, 95% CI 1.99-6.90, bifurcation lesions (OR=2.43, 95% CI 1.16-5.10, smoking (OR=2.30, 95% CI 1.33-3.99, vascular diameter (OR=2.18, 95% CI 1.2-3.73, hypertension (OR=2.16, 95% CI 1.16-4.04 and diabetes mellitus (OR=2.14, 95% CI 1.23-3.70. Conclusion: stent type, stent length, bifurcation lesions, smoking, vascular diameter, hypertension and DM are factors associated with ISR in patients following PCI. Key words: bare-metal stent; drug-eluting stent; in-stent restenosis.

  15. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  16. Self-expandable metalic endotracheal stent

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author).

  17. Risk factors for in-stent restenosis of vertebral artery origin after stent implantation: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Fang-fang HAO

    2018-01-01

    Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004

  18. Clinical presentation and outcomes of coronary in-stent restenosis across 3-stent generations.

    Science.gov (United States)

    Magalhaes, Marco A; Minha, Sa'ar; Chen, Fang; Torguson, Rebecca; Omar, Al Fazir; Loh, Joshua P; Escarcega, Ricardo O; Lipinski, Michael J; Baker, Nevin C; Kitabata, Hironori; Ota, Hideaki; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-12-01

    Clinical presentation of bare metal stent in-stent restenosis (ISR) in patients undergoing target lesion revascularization is well characterized and negatively affects on outcomes, whereas the presentation and outcomes of first- and second-generation drug-eluting stents (DESs) remains under-reported. The study included 909 patients (1077 ISR lesions) distributed as follows: bare metal stent (n=388), first-generation DES (n=425), and second-generation DES (n=96), categorized into acute coronary syndrome (ACS) or non-ACS presentation mode at the time of first target lesion revascularization. ACS was further classified as myocardial infarction (MI) and unstable angina. For bare metal stent, first-generation DES and second-generation DES, ACS was the clinical presentation in 67.8%, 71.0%, and 66.7% of patients, respectively (P=0.470), whereas MI occurred in 10.6%, 10.1%, and 5.2% of patients, respectively (P=0.273). The correlates for MI as ISR presentation were current smokers (odds ratio, 3.02; 95% confidence interval [CI], 1.78-5.13; Ppresentations had an independent effect on major adverse cardiac events (death, MI, and re-target lesion revascularization) at 6 months (MI versus non-ACS: adjusted hazard ratio, 4.06; 95% CI, 1.84-8.94; Pclinical presentation is similar irrespective of stent type. MI as ISR presentation seems to be associated with patient and not device-related factors. ACS as ISR presentation has an independent effect on major adverse cardiac events, suggesting that ISR remains a hazard and should be minimized. © 2014 American Heart Association, Inc.

  19. Intravascular stenting in the superior mesenteric artery for chronic abdominal angina.

    Science.gov (United States)

    Busquet, J

    1997-11-01

    Abdominal angina is an early clinical expression of occlusive mesenteric arterial insufficiency, a condition that requires aggressive treatment to prevent intestinal infarction. We report a case of chronic mesenteric ischemia in a young polyvascular man who had symptoms of abdominal angina. An aortic angiogram revealed a significant ostial stenosis of the superior mesenteric artery (SMA) associated with an occlusion of the inferior mesenteric artery. After predilation of the ostial portion of the SMA, significant residual stenosis remained. A balloon-expandable Palmaz P154 stent was deployed, restoring adequate luminal dimensions and blood flow. The patient was discharged after 2 days and remains asymptomatic at 5 months. Intraluminal stenting for treatment of mesenteric ischemia represents a viable alternative to surgical revascularization in selected cases.

  20. Effect of cilostazol on in-stent neointimal hyperplasia after coronary artery stenting. A quantitative coronary angiography and volumetric intravascular ultrasound study

    International Nuclear Information System (INIS)

    Min, Pil-Ki; Jung, Jae-Hun; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Shim, Won-Heum

    2007-01-01

    This study was designed to investigate the efficacy of cilostazol on the prevention of in-stent neointimal hyperplasia as measured by both quantitative coronary angiography (CAG) and volumetric intravascular ultrasound (IVUS). Fifty-nine patients (39 men, age 62 years) undergoing elective coronary stenting were randomly assigned to receive aspirin plus clopidogrel or ticlopidine (Group I, n=28, 30 lesions) or aspirin plus clopidogrel or ticlopidine plus cilostazol (Group II, n=31, 35 lesions). CAG and IVUS were performed and repeated at 6 months to assess the primary endpoints of minimal luminal diameter (MLD) and in-stent neointimal hyperplasia volume. Follow-up CAG was performed on all patients and follow-up IVUS study was available for 50 lesions in 48 patients (24 lesions in Group I, 26 in Group II). There were no significant differences in the baseline angiographic data between the 2 groups. At 6 months follow-up, in-stent MLD was 1.90±0.76 mm in Group I and 2.41±0.85 mm in Group II (p=0.006). Volumetric IVUS at 6 months demonstrated that in-stent intimal hyperplasia volume per stent length was 2.2±1.4 mm 3 /mm in Group I and 1.0±0.5 mm 3 /mm in Group II (p=0.001). Triple antiplatelet therapy including cilostazol seems to be more effective at preventing in-stent neointimal hyperplasia than a dual antiplatelet regimen. (author)

  1. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  2. Routine short-term ureteral stent in living donor renal transplantation: introduction of a simple stent removal technique without using anesthesia and cystoscope.

    Science.gov (United States)

    Dong, J; Lu, J; Zu, Q; Yang, S; Sun, S; Cai, W; Zhang, L; Zhang, X

    2011-12-01

    We evaluated routine short-time insertion of ureteral stent in living donor renal transplant at a single center. It was easy to remove the stent without cystoscopy and anesthesia. Between October 2007 and July 2010, a single surgeon performed 76 living donor renal transplantations at one institute. All recipients underwent extravesical ureteroneocystostomy with a 2-0 silk suture passed through the venting side hole of the double-J stent into the bladder; a quadruple knot prevented the suture's slippage or distraction from the stent. After removal of the indwelling catheter at 5 days posttransplantation, the 2-0 silk passed with the urinary stream within 72 hours. The double-J stent was removed at 7 to 10 (mean 8.4) days after kidney transplantation by pulling the 2-0 silk out of the urethral orifice without anesthesia or cystoscopy. There was only one case of stenosis, which was resolved by surgery. No patient developed urinary leakage. There were three episodes of urinary tract infection in 70 patients during first 6 months' follow-up. Routine short-term stenting is a safe and effective technique in living donor renal transplantation. Removal of the stent is feasible without cystoscopy or anesthesia. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Development and characterization of microsatellite loci in the endangered species Taxus wallichiana (Taxaceae).

    Science.gov (United States)

    Gajurel, Jyoti Prasad; Cornejo, Carolina; Werth, Silke; Shrestha, Krishna Kumar; Scheidegger, Christoph

    2013-03-01

    Microsatellite primers were developed in the endangered tree species Taxus wallichiana from Nepal to investigate regional genetic differentiation, local genetic diversity, and gene flow for the conservation of this species under climate- and land-use change scenarios in mountain regions of Nepal. • We developed 10 highly polymorphic microsatellite markers from 454 DNA sequencing. Characterization of the new microsatellite loci was done in 99 individuals collected from three valleys with different climatic regimes. The number of alleles per locus varied from four to 12. Observed heterozygosity of populations, averaged across loci, ranged from 0.30 to 0.59. • The new markers provided by this study will substantially increase the resolution for detailed studies in phylogeography, population genetics, and parentage analysis.

  4. Slippery when sticky: Lubricating properties of thin films of Taxus baccata aril mucilage

    DEFF Research Database (Denmark)

    Røn, Troels; Sankaranarayanan, Rishikesan; Chronakis, Ioannis S.

    2016-01-01

    Mucilage is hydrogel produced from succulent plants and microorganisms displaying unique adhesiveness and slipperiness simultaneously. The objective of this study is to establish an understanding on the lubricating mechanisms of the mucilage from Taxus baccata aril as thin, viscous lubricant films....... Oscillation and flow rheological studies revealed that T. baccata mucilage is shear-thinning, thixotropic, and weak hydrogel that is highly stretchable under shear stress due to its high density physical crosslinking characteristics. In addition, T. baccata mucilage showed a distinct Weissenberg effect, i...... effectively manifested at soft, hydrophilic, and rolling tribological contacts. Based on tenacious spreading on highly wettingsurfaces, slip plane can be formed within mucilage hydrogel network even when the lubricating films cannot completely separate the opposing surfaces. Moreover, highly stretchable...

  5. Future developments in biliary stenting

    Science.gov (United States)

    Hair, Clark D; Sejpal, Divyesh V

    2013-01-01

    Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting. PMID:23837001

  6. Characterization and mechanical investigation of Ti–O2−x film prepared by plasma immersion ion implantation and deposition for cardiovascular stents surface modification

    International Nuclear Information System (INIS)

    Xie Dong; Wan Guojiang; Maitz, Manfred F.; Lei Yifeng; Huang Nan; Sun Hong

    2012-01-01

    Highlights: ► We prepared Ti–O 2−x films of good quality by PIII and D successfully on stents product. ► The Ti–O 2−x film shows good homogeneity and intergradient film/substrate interface. ► The Ti–O 2−x films on stent sustain clinically-required expansion without failure. ► The films show good mechanical durability for cardiovascular stents application. - Abstract: Up to date, materials for cardiovascular stents are still far from satisfactory because of high risk of biomaterials-associated restenosis and thrombosis. Extensive efforts have been made to improve the biocompatibility of the materials by various surface modification techniques. Ti–O 2−x films prepared by plasma immersion ion implantation and deposition (PIII and D) have shown good blood compatibility. For clinical application, surface quality and mechanical durability of the Ti–O 2−x film on stents are also of critical importance for the long-term serving. In this paper we present our research results on surface quality, mechanical investigation and characterization of Ti–O 2−x films prepared using PIII and D on stent products provided by Boston Scientific SCIMED. Ti–O 2−x films with mostly Rutile and little non-stoichiometric phases were obtained with smoothness of 2−x films on stents products were sustained balloon-expansion of clinically-required extent without mechanical failure, showing highly potential feasibility for cardiovascular stents application.

  7. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  8. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    Science.gov (United States)

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  9. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    Science.gov (United States)

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  10. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Stent occlusion occurred in 4 patients (8%) within a week as result of stent migration (n=3) or presumed biliary sludge (n=1); 2 (4%) stents occluded between 7 days and 1 month. Four patients (8%) died during hospital admission due to pre-existing biliary sepsis (n=3) and pneumonia (n=1). Nine patients developed ...

  12. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  13. Safety and efficacy of everolimus-eluting stents compared with first-generation drug-eluting stents in patients undergoing primary percutaneous coronary intervention

    Energy Technology Data Exchange (ETDEWEB)

    Escárcega, Ricardo O.; Baker, Nevin C.; Magalhaes, Marco A.; Lipinski, Michael J.; Minha, Sa’ar; Torguson, Rebecca; Satler, Lowell F.; Pichard, Augusto D.; Suddath, William O.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-09-15

    Objective: To assess the safety and efficacy everolimus-eluting stents (EES) compared with first-generation drug-eluting stents (DES) in patients with acute myocardial infarction (MI) undergoing primary percutaneous coronary intervention (PCI). Background: EES have been associated with improved clinical outcomes compared to paclitaxel-eluting stents (PES) and with similar outcomes compared to sirolimus-eluting stents (SES). Methods: A total of 520 patients who presented with ST-elevation myocardial infarction (STEMI) from 2003 to 2013, who underwent primary PCI with DES, were retrospectively analyzed. Of these, 247 received SES, 136 PES, and 137 EES. Patients were followed up to 2 years for major adverse cardiac events (MACE). Univariate and multivariate models detected correlates to outcome. Results: EES implantation, compared with PES and SES, resulted in comparable rates of MACE (8.8% vs. 16.2%, p = 0.06 and 8.8% vs. 12.6%, respectively, p = 0.26), stent thrombosis, MI, and target lesion revascularization. Patients who received EES had lower rates of all-cause mortality (3.7% vs. 12.6% vs. 9.4%, p = 0.03) at 1-year follow up. However, in the univariate and multivariate analyses, stent type was not independently associated with the primary outcome or with all-cause mortality. Diabetes mellitus and number of stents implanted were independently associated with the primary outcome. Conclusion: While EES seem to be associated with better outcome when compared to PES, the main correlates of STEMI patients are the presence of diabetes and number of stents implanted, and not the type of stent used for intervention.

  14. [Evaluation of stents in treating childhood benign esophageal strictures].

    Science.gov (United States)

    Reinshagen, K; Kähler, G; Manegold, B C; Waag, K-L

    2009-01-01

    Esophageal stenting is a popular of treatment of esophageal strictures in adults. It has also been described for children with benign strictures who did not respond to standard dilatation therapy. The aim of the study was to evaluate weather esophageal stents could be used safely and effectively in the treatment of benign esophageal strictures in children. From 1993 to 2005 stenting therapy was performed in 12 children with complicated esophageal strictures. Etiologies of the strictures were caustic burns in 9 patients, postoperative strictures due to complicated esophageal atresia in 2 patients and iatrogenic esophageal injury in 1 patient. Esophageal silicon tubi, covered retrievable expandable nitinol and plastic stents were placed endoscopically. The clinical course and the long term follow up were evaluated retrospectively The stents and tubi were placed in all patients without complications and were later removed successfully. 6 patients were treated with a self expanding plastic stent. The plastic stents showed a distinct tendency to migrate but in 5/6 patients esophageal stricture was treated successfully. 3 patients were treated by a covered self expanding nitinol stent. No migration occurred. One patient was asymptomatic after therapy, one required further dilatation therapy and the third had esophageal resection. 3 patients were treated by esophageal tubi. 2 patients required surgery in the follow up, one patient is asymptomatic. The use of stenting devices in children to treat benign esophageal strictures is safe and efficient. The self expanding plastic stents had the best long term results but required high compliance of parents and children due to the tendency of stent migration. Self expanding nitinol stents are more traumatic at the extraction procedure and are useful in patients with low compliance. Recurrence of strictures occurred most often after esophageal tubi possibly due to the lack of radial expansion.

  15. Drug-eluting stents and bare metal stents in patients with NSTE-ACS

    DEFF Research Database (Denmark)

    Pedersen, Sune Haahr; Pfisterer, Matthias; Kaiser, Christoph

    2014-01-01

    the randomised BASKET-PROVE trial (sirolimus-eluting stent vs. everolimus-eluting stent vs. bare metal stent in large-vessel stenting). The primary endpoint was the combined two-year rate of cardiovascular death or non-fatal myocardial infarction (MI). Secondary endpoints were each component of the primary...... implantation in large vessels was associated with a reduction in both TVR and the combined endpoint consisting of cardiovascular death/MI. Thus, DES use improves both efficacy and safety. These findings support the use of DES in NSTE-ACS patients....

  16. [Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis].

    Science.gov (United States)

    Wang, Zheng-yu; Wang, Yong-li; Chen, Guang-li; Liang, Xi-hong; Wang, Zhen-chang; Ma, Jian-zhong; Wu, Guang-zhong; Zhang, Xiao-ping

    2012-11-01

    To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis. Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis. Stent-related complications and the management were reviewed and analysed. Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients. Stents were removed 4 - 12 months [mean (5.5 ± 2.2) mouths] after placement in all patients. Stent-related complications included granulation tissue (n = 18), stent migration (n = 4), stent expectoration (n = 2), halitosis (n = 8), mucous retention (n = 21) and mucus plugging (n = 1). Granulation tissue was removed with a carbon dioxide laser in 2 patients. Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration. An additional stent was placed in 2 patients after stent migration. Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients. Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation. Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient. There were statistically significant differences in stricture diameter, rank of tachypnea and pulmonary function (FEV(1)) in all 21 patients before stent insertion and after stents removal. No patient has experienced recurrence during the follow-up period of 1 - 36 months [mean (23.2 ± 8.0) months]. Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis. Stent-related complications may be effectively managed.

  17. Mechanism for esophagus-jejunum stent bypass in the treatment of type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Suo-lin FU

    2012-09-01

    Full Text Available Objective To observe the effect of endoscopic esophagus-jejunum covered stent bypass on the treatment of type 2 diabetes mellitus (T2DM, and analyze the mechanism thereof. Methods Five obese Beagle dog models of T2DM underwent endoscopic esophagus-jejunum covered stent bypass to serve as operation group, and five normal Beagle dogs as control group receive endoscopy and exploratory laparotomy. The T2DM indices of both groups, including fast plasma glucose (FPG level, fast insulin (FINS level, intravenous glucose tolerance test-2h plasma glucose (IVGTT-2h PG and IVGTT-2h FINS, were determined regularly before operation and 4, 8 and 12 weeks after operation. The insulin resistance index (HOMA-IR and the function of islet β-cell (HOMA-β were calculated with Homeostasis Model Assessment. The levels of gastric inhibitory polypeptide (GIP and glucagon-like peptide-1(GLP-1 were also determined. Results Four weeks after operation, FPG, FINS, IVGTT-2h PG, and IVGTT-2h FINS all decreased significantly in operation group (P 0.05. The HOMA-IR index declined distinctly and HOMA-β index ascended obviously in operation group 4 weeks after operation (P 0.05. The level of GIP lowered significantly (P 0.05. Conclusion T2DM may be treated with esophagus-jejunum covered stent bypass effectively and safely, and the mechanism thereof might be related to the changes in gastrointestinal hormones.

  18. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  19. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  20. Percutaneous nephrostomy and antegrade ureteral stenting: technique - indications - complications

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, Klaus A. [Klagenfurt General Hospital, Department of Radiology, Klagenfurt (Austria); Portugaller, Horst R. [University Hospital of Graz, Department of Radiology, Graz (Austria)

    2006-09-15

    In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN. Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory. (orig.)

  1. Novel silicone stent to treat tracheobronchial lesions: results of 35 patients.

    Science.gov (United States)

    Saueressig, Maurício G; Sanches, Paulo R S; Macedo Neto, Amarilio V; Moreschi, Alexandre H; Oliveira, Hugo G; Xavier, Rogerio G

    2010-12-01

    We describe a case series of 35 patients with either benign (14) or malignant (21) tracheal stenosis who were treated using a novel silicone stent, the HCPA-1, designed to prevent migration. Between March 2001 and September 2008, 13 women and 22 men received 41 HCPA-1 stents. The median duration of stenting in benign cases was 457 days (range, 4-2,961 days). Successful stent removal with curative results was accomplished in 2 patients with tracheomalacia and 1 with post-intubation stenosis. In malignant cases, the median duration of stenting was 162 days (range, 1-1,279 days). Five patients had tumor progression with obstruction requiring repeated laser resection, dilatation, or additional stents. Two patients died due to airway obstruction despite bronchoscopic intervention. Twelve patients with malignant lesions died with the stent in place. At the end of the study, 3 patients with malignant disease remained alive; 2 were lost to follow-up. The HCPA-1 stent proved to be safe, with no severe complications during the study period, and effective in improving quality of life with relief of dyspnea.

  2. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  3. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  4. Revisiting the tethered ureteral stents in children: a novel modification.

    Science.gov (United States)

    Kajbafzadeh, Abdol-Mohammad; Nabavizadeh, Behnam; Keihani, Sorena; Hosseini Sharifi, Seyed Hossein

    2015-06-01

    To propose a simple noninvasive method for ureteral stent retrieval using an extraction string sutured to the skin in children. A retrospective chart review was performed to gather relevant data from December 2005 to February 2013. After the surgeries, if indicated, a tethered double-J stent was placed in the ureter. A 5-0 non-absorbable Prolene stitch was used as an extraction string passing through the urethra and was sutured to subcoronal skin in boys or inner surface of labia majora in girls. For stent removal, a small amount of 2 % lidocaine jelly was pushed into the urethra 5 min before the procedure. The string was then pulled by continuous and gentle force until the entire stent was out. The suture was then cut to release the stent. No sedation or anesthesia was needed. A total of 378 double-J stents with extraction strings were inserted for a total of 325 patients (61.2 % male). Of the 53 patients with bilateral ureteral stents, one male patient (1.88 %) experienced early stent protrusion from urethral meatus. Two of 272 patients (0.73 %) with unilateral ureteral stent (one male and one female) encountered the same problem. All other stents were extracted successfully using the extraction string without any complications. No upward stent migration or suture site reaction was encountered. This method is a safe, easy-to-use, feasible and noninvasive alternative for cystoscopic stent removal with high success rate and minimal complications. This can lead to considerable saving in time and costs for patients, families and healthcare system.

  5. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  6. Fully covered stents versus partially covered stents for palliative treatment of esophageal cancer: Is there a difference?

    Science.gov (United States)

    Alonso Lárraga, J O; Flores Carmona, D Y; Hernández Guerrero, A; Ramírez Solís, M E; de la Mora Levy, J G; Sánchez Del Monte, J C

    2018-02-26

    Malignant dysphagia is difficulty swallowing resulting from esophageal obstruction due to cancer. The goal of palliative treatment is to reduce the dysphagia and improve oral dietary intake. Self-expandable metallic stents are the current treatment of choice, given that they enable the immediate restoration of oral intake. The aim of the present study was to describe the results of using totally covered and partially covered esophageal stents for palliating esophageal cancer. A retrospective study was conducted on patients with inoperable esophageal cancer treated with self-expandable metallic stents. The 2 groups formed were: group A, which consisted of patients with a fully covered self-expandable stent (SX-ELLA ® ), and group B, which was made up of patients with a partially covered self-expandable stent (Ultraflex ® ). Of the 69-patient total, 50 were included in the study. Group A had 19 men and 2 women and their mean age was 63.6 years (range 41-84). Technical success was achieved in 100% (n=21) of the cases and clinical success in 90.4% (n=19). Group B had 24 men and 5 women and their mean age was 67.5 years (range 43-92). Technical success was achieved in 100% (n=29) of the cases and clinical success in 89.6% (n=26). Complications were similar in both groups (33.3 vs. 51.7%). There was no difference between the 2 types of stent for the palliative treatment of esophageal cancer with respect to technical success, clinical success, or complications. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  7. Colonic stenting as bridge to surgery versus emergency surgery for management of acute left-sided malignant colonic obstruction: a multicenter randomized trial (Stent-in 2 study

    Directory of Open Access Journals (Sweden)

    Scholten Pieter

    2007-07-01

    analysis of variance. Mortality will be compared using Kaplan-Meier curves and log-rank statistics. Discussion The Stent-in 2 study is a randomized controlled multicenter trial that will provide evidence whether or not colonic stenting as bridge to surgery is to be performed in patients with acute left-sided colonic obstruction. Trial registration Current Controlled Trials ISRCTN46462267.

  8. Incidence and Clinical Features of Early Stent Thrombosis in the Era of New P2y12 Inhibitors (PLATIS-2.

    Directory of Open Access Journals (Sweden)

    Elad Asher

    Full Text Available Early stent thrombosis (EST (≤ 30 days after stent implantation is a relatively rare but deleterious complication of percutaneous coronary intervention (PCI. Administration of newer P2Y12 inhibitors (prasugrel and ticagrelor combined with aspirin has been shown to reduce the incidence of sub-acute and late stent thrombosis, compared with clopidogrel. We investigated the "real life" incidence of EST in patients from a large acute coronary syndrome (ACS national registry, where newer P2Y12 inhibitors are widely used. Patients were derived from the ACS Israeli Survey (ACSIS, conducted during 2006, 2008, 2010 and 2013. Major adverse cardiac events (MACE at 30days were defined as all-cause death, recurrent ACS, EST and stroke.Of the 4717 ACS patients who underwent PCI and stenting, 83% received clopidogrel and 17% newer P2Y12 inhibitors. The rate of EST was similar in both groups (1.7% in the newer P2Y12 inhibitor group vs. 1.4% in the clopidogrel-treated patients, p = 0.42. Results were consistent after multivariate analysis (adjusted HR = 1.06 [p = 0.89]. MACE occurred in 6.4% in the newer P2Y12 inhibitor group compared with 9.2% in the clopidogrel group (P<0.01. However, multivariate logistic regression modeling showed that treatment with newer P2Y12 inhibitors was not significantly associated with the secondary endpoint of MACE when compared with clopidogrel therapy [OR = 1.26 95%CI (0.93-1.73, P = 0.136]. The incidence of "real life" EST at 1month is relatively low, and appears to be similar in patients who receive newer P2Y12 inhibitors as well as in those who receive clopidogrel.

  9. Incidence and Clinical Features of Early Stent Thrombosis in the Era of New P2y12 Inhibitors (PLATIS-2)

    Science.gov (United States)

    Asher, Elad; Abu-Much, Arsalan; Goldenberg, Ilan; Segev, Amit; Sabbag, Avi; Mazin, Israel; Shlezinger, Meital; Atar, Shaul; Zahger, Doron; Polak, Arthur; Beigel, Roy; Matetzky, Shlomi

    2016-01-01

    Early stent thrombosis (EST) (≤ 30 days after stent implantation) is a relatively rare but deleterious complication of percutaneous coronary intervention (PCI). Administration of newer P2Y12 inhibitors (prasugrel and ticagrelor) combined with aspirin has been shown to reduce the incidence of sub-acute and late stent thrombosis, compared with clopidogrel. We investigated the “real life” incidence of EST in patients from a large acute coronary syndrome (ACS) national registry, where newer P2Y12 inhibitors are widely used. Patients were derived from the ACS Israeli Survey (ACSIS), conducted during 2006, 2008, 2010 and 2013. Major adverse cardiac events (MACE) at 30days were defined as all-cause death, recurrent ACS, EST and stroke.Of the 4717 ACS patients who underwent PCI and stenting, 83% received clopidogrel and 17% newer P2Y12 inhibitors. The rate of EST was similar in both groups (1.7% in the newer P2Y12 inhibitor group vs. 1.4% in the clopidogrel-treated patients, p = 0.42). Results were consistent after multivariate analysis (adjusted HR = 1.06 [p = 0.89]). MACE occurred in 6.4% in the newer P2Y12 inhibitor group compared with 9.2% in the clopidogrel group (P<0.01). However, multivariate logistic regression modeling showed that treatment with newer P2Y12 inhibitors was not significantly associated with the secondary endpoint of MACE when compared with clopidogrel therapy [OR = 1.26 95%CI (0.93–1.73), P = 0.136]. The incidence of "real life" EST at 1month is relatively low, and appears to be similar in patients who receive newer P2Y12 inhibitors as well as in those who receive clopidogrel. PMID:27310147

  10. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  11. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  12. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  13. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  14. [Drug-eluting stent thrombosis and its pharmacological prevention].

    Science.gov (United States)

    Pershukov, I V; Batyraliev, T A

    2007-01-01

    The problem of drug eluting stents (DES) safety has been actively discussed throughout 2006 because of increase of frequency of development of late stent thromboses which were noted during almost 2 years after stenting. In December 2006 US Food and Drug Administration (FDA) advisory panel acknowledged increase of development of late stent thrombosis. At the same time FDA accepted new definition of stent-thrombosis suggested by the Academic Research Consortium. According to this definition thrombosis can be definite, probable and possible. Any unexplained death before end of follow-up in a trial should be considered thrombosis related. Recalculation of thrombosis rate using this definition caused pronounced increase of this parameter in previously conducted trials. Thrombosis rate rose from 0,6 to 3,3% for bare metal stents, from 0,8 to 3,6% for sirolimus eluting stents and from 1,3 to 3,5% for paclitaxel eluting stents. Professional cardiological and angiographical societies (ACC, AHA, SCAI) responding to FDA advisory panel published their proofs and vision of the problem of stent thrombosis. In February 2007 ACC, AHA, SCAI, American College of Surgeons and Association of Dentists published scientific bulletin in which described preventive measures aimed at lowering of risk of thrombosis development. This document contains strict recommendation to continue double antithrombotic therapy with aspirin and clopidogrel for 12 months after implantation of DES or abandonment of the use of this type of stents when long term double antithrombotic therapy is not possible.

  15. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  16. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    Science.gov (United States)

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the

  17. Experimental use of new absorbable tracheal stent.

    Science.gov (United States)

    Schopf, Luciano F; Fraga, José Carlos; Porto, Rodrigo; Santos, Luis A; Marques, Douglas R; Sanchez, Paulo R; Meyer, Fabíola S; Ulbrich, Jane M

    2017-11-16

    Silicone and metallic stents are not effective in children with tracheobronchial stenosis or tracheomalacia. Herein, we aimed to evaluate the clinical manifestations and histological reaction of rabbit trachea to the presence of a new poly(lactic-co-glycolic acid) with polyisoprene (PLGA/PI) polymer absorbable stent. Fourteen adult white rabbits (weight, 3.0-3.5kg) were randomly assigned to three groups: Group I (n=6): PLGA/PI spiral stent; Group II (n=6): PLGA/PI fragment; and Group III (n=2): controls. After a longitudinal incision on three cervical tracheal rings, the stents and fragments were inserted into the trachea and fixed onto the lateral wall with nonabsorbable sutures. The stented group showed significantly more stridor at rest (p=0.0041), agitation (p=0.014), and use of accessory muscles (p=0.0002) and required more emergency endoscopies than the fragment group. Further, it showed significantly more remarkable histological inflammatory damage than the fragment and control groups (p=0.002). The new PLGA/PI polymeric stent implanted into the trachea of rabbits caused more clinical manifestations and histologically verified inflammatory reaction than the PLGA/PI polymeric fragment. Future studies should be aimed at reducing the stent-wall thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  19. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  20. Transient coronary aneurysm formation after Nevo™ stent implantation versus persistent coronary aneurysm after Cypher Select™ stent implantation

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Lassen, Jens Flensted; Jensen, Lisette Okkels

    2011-01-01

    We implanted a Cypher Select™ coronary stent and two months later a Nevo™ sirolimus-eluting coronary stent in another vessel. At a prescheduled angiographic follow-up, coronary aneurysms were seen in the two stented segments, 6 and 8 months after stent implantation, respectively. Six months later......, the aneurysm had healed in the Nevo, but was still present in the Cypher stented segment. We hypothesize that aneurysm formation was induced by sirolimus and the polymer of the implanted stents, and that subsequent healing was possible in the Nevo stent after degradation of the polymer....

  1. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  2. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  3. Development and Characterization of Microsatellite Loci in the Endangered Species Taxus wallichiana (Taxaceae

    Directory of Open Access Journals (Sweden)

    Jyoti Prasad Gajurel

    2013-03-01

    Full Text Available Premise of the study: Microsatellite primers were developed in the endangered tree species Taxus wallichiana from Nepal to investigate regional genetic differentiation, local genetic diversity, and gene flow for the conservation of this species under climate- and land-use change scenarios in mountain regions of Nepal. Methods and Results: We developed 10 highly polymorphic microsatellite markers from 454 DNA sequencing. Characterization of the new microsatellite loci was done in 99 individuals collected from three valleys with different climatic regimes. The number of alleles per locus varied from four to 12. Observed heterozygosity of populations, averaged across loci, ranged from 0.30 to 0.59. Conclusions: The new markers provided by this study will substantially increase the resolution for detailed studies in phylogeography, population genetics, and parentage analysis.

  4. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Science.gov (United States)

    2012-01-01

    Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816

  5. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  6. Comparison of visibility for four self-expanding nitinol bare stents in vitro

    International Nuclear Information System (INIS)

    Wiesinger, Benjamin; Stutz, Alexander; Schmehl, Joerg; Groezinger, Gerd; Claussen, Claus Detlef; Wiskirchen, Jakub

    2012-01-01

    Background Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents. Purpose To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis. Material and Methods We evaluated the ODR (as a percentage of correctly identified stents) and the SRS (on a scale from 0 = not visible to 4 = excellent visibility) for four self-expanding nitinol stents (SinusSuperflex, SMART, Luminexx, Zilver) with 8 mm diameter and 40 mm length. Stents were placed on a phantom human pelvis and images of the stents were taken in four different positions (right and left lumbosacral joint and near the right and left limbus acetabuli) using the following modes: spotfilm, pulsed fluoroscopy (4, 7.5, 15, and 30 pulses/min) and at three different digital magnification modes. Dose area products (DAPs) were assessed. Results ODR and SRS, respectively, were significantly increased for the SMART stent compared to all other tested stents (P < 0.05): SMART 93.53% and 2.43, SinusSuperflex 90.81% and 2.21, Luminexx 90.39% and 2.20, and Zilver 89.28% and 2.21. ODR was significantly reduced in position 3 where the bone overlap was more pronounced for all stents (detection rates 77.14-79.56%). An increase in magnification significantly improved the ODR and SRS for all stents (70.33-99.25% and 1.07-3.28, respectively, P < 0.05). Increased pulsing frequency did not improve the ODR of the various stents but did increase the DAP. Conclusion The SMART stent had the best overall performance. In the presence of bone overlap, all self-expanding nitinol stents had poor results. Increased pulsing frequency did not improve ODR or SRS but did increase the DAP. Use of digital magnification modes had no effect on DAP increasing ODR

  7. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  8. Experimental study with gianturco stent in the trachea of rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Kook; Kim, Yun Hwan; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1991-09-15

    An expendable stainless steel stent was formulated for use in treatment of tracheobronchial stenosis, tracheomalacia and air way collapse following tracheal reconstruction. The stents were placed throughout an endobronchial tube into the trachea of 20 healthy rabbits. Two different of sizes (10mm, A type and 20mm, B type in diameter and length) and two kinds of shapes (standard, A and B and modified, A' and B' with barbs) were used. Group I were used with A and A' type stents and group II were used with B and B' types. The animals were observed under fluoroscopy and findings were later confirmed at autopsy. With the exception of 2 cases where the stents migrated. 1 case in A subgroup and A' and an inflammatory reaction was noted in each animal. Group II rabbits were almost died within 2-4 weeks after stent placement. In the comparison of the pathohistologic findings between group I and II, the tissue necrosis at the sites of stent placement in trachea is more severe and extensive in group II than that of group I, and also reactive fibroblastic reaction is more severe in group II. So the thickness of the tracheal wall in group II is two or three times thicker than that of group I which seems to be a result of reactive fibrosis. So, A and A' type stent is safer than B and B' type stent in normal rabbit trachea. It is advisable to use stents in diameter under 2 times to tracheal width and the complication of stent placement in trachea may be reduced for appropriate reconstruction of stenotic lesion.

  9. Experimental study with gianturco stent in the trachea of rabbit

    International Nuclear Information System (INIS)

    Park, Jeong Kook; Kim, Yun Hwan; Suh, Won Hyuck

    1991-01-01

    An expendable stainless steel stent was formulated for use in treatment of tracheobronchial stenosis, tracheomalacia and air way collapse following tracheal reconstruction. The stents were placed throughout an endobronchial tube into the trachea of 20 healthy rabbits. Two different of sizes (10mm, A type and 20mm, B type in diameter and length) and two kinds of shapes (standard, A and B and modified, A' and B' with barbs) were used. Group I were used with A and A' type stents and group II were used with B and B' types. The animals were observed under fluoroscopy and findings were later confirmed at autopsy. With the exception of 2 cases where the stents migrated. 1 case in A subgroup and A' and an inflammatory reaction was noted in each animal. Group II rabbits were almost died within 2-4 weeks after stent placement. In the comparison of the pathohistologic findings between group I and II, the tissue necrosis at the sites of stent placement in trachea is more severe and extensive in group II than that of group I, and also reactive fibroblastic reaction is more severe in group II. So the thickness of the tracheal wall in group II is two or three times thicker than that of group I which seems to be a result of reactive fibrosis. So, A and A' type stent is safer than B and B' type stent in normal rabbit trachea. It is advisable to use stents in diameter under 2 times to tracheal width and the complication of stent placement in trachea may be reduced for appropriate reconstruction of stenotic lesion

  10. Experimental study with gianturco stent in the trachea of rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Kook; Kim, Yun Hwan; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1991-09-15

    An expendable stainless steel stent was formulated for use in treatment of tracheobronchial stenosis, tracheomalacia and air way collapse following tracheal reconstruction. The stents were placed throughout an endobronchial tube into the trachea of 20 healthy rabbits. Two different of sizes (10mm, A type and 20mm, B type in diameter and length) and two kinds of shapes (standard, A and B and modified, A' and B' with barbs) were used. Group I were used with A and A' type stents and group II were used with B and B' types. The animals were observed under fluoroscopy and findings were later confirmed at autopsy. With the exception of 2 cases where the stents migrated. 1 case in A subgroup and A' and an inflammatory reaction was noted in each animal. Group II rabbits were almost died within 2-4 weeks after stent placement. In the comparison of the pathohistologic findings between group I and II, the tissue necrosis at the sites of stent placement in trachea is more severe and extensive in group II than that of group I, and also reactive fibroblastic reaction is more severe in group II. So the thickness of the tracheal wall in group II is two or three times thicker than that of group I which seems to be a result of reactive fibrosis. So, A and A' type stent is safer than B and B' type stent in normal rabbit trachea. It is advisable to use stents in diameter under 2 times to tracheal width and the complication of stent placement in trachea may be reduced for appropriate reconstruction of stenotic lesion.

  11. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  12. Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Yu; Wang Ning; Tian Qihe; Guo Zhanwen; Zhang Haibo; Song Liyan

    2005-01-01

    Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 ± 4.6 months, compared with 5.1 ± 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

  13. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    International Nuclear Information System (INIS)

    Wilhelm, K.E.; Grabolle, B.; Urbach, H.; Tolba, R.; Schild, H.; Paulsen, F.

    2006-01-01

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted without major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency

  14. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  15. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  16. [The Predictive Factors of Stent Failure in the Treatment of Malignant Extrinsc Ureteral Obstruction Using Internal Ureteral Stents].

    Science.gov (United States)

    Matsuura, Hiroshi; Arase, Shigeki; Hori, Yasuhide; Tochigi, Hiromi

    2017-12-01

    In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.

  17. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    Science.gov (United States)

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  18. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  19. Six-Month Clinical and Angiographic Results of Paclitaxel Eluting Simpax Stent

    Directory of Open Access Journals (Sweden)

    Mehmet Muhsin Türkmen

    2012-08-01

    Full Text Available Introduction: We aimed to evaluate the safety and efficacy of the simpax stent in the treatmentof different patient groups.Patients and Methods: Forty-five patients were treated with the simpax stent. Of these patients,23 patients gave consent for six months of follow-up by quantitative coronary angiography (QSAand six patients were evaluated by exercise electrocardiographic test. Only the patients havinglesions with stenosis > 50% of diameter and lengths > 16 mm with reference diameters < 2.75mm were included.Results: The device success rate was 100% and procedure success rate was 97.7%. The meanstent length was 24.6 ± 7.3 mm and stent size was 2.54 ± 0.24 mm. The overall six months incidenceof major adverse cardiac events (MACE was 8.8%. MACE was consisted of two casesof non-Q wave myocardial infarction and two cases of repeated revascularization of the targetlesion. MACE rate was higher in chronic total occlusion (CTO group than non-CTO group (respectively33.3% and 5.1. Also when compared to stent size, MACE rate was 25% in < 2.5 mm,0% ≥ 2.5 mm. The QSA results at six months showed in-stent late lumen loss witha diameter of0.25 ± 0.15 mm in 17 patients.Conclusion: The six month results in this study demonsrated excellent procedural and devicesuccess. Simpax stent was associated with a low in-stent late lumen loss. Also this study showedsimpax stent was a safe and effective device in non-CTO group with stent size ≥ 2.5 mm.

  20. Neointimal responses 3 months after 32P β-emitting stent placement

    International Nuclear Information System (INIS)

    Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu

    2000-01-01

    Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy

  1. Stent Design Affects Femoropopliteal Artery Deformation.

    Science.gov (United States)

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  2. Clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting

    Directory of Open Access Journals (Sweden)

    Xiang-yu CAO

    2016-12-01

    Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected.  Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001.  Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein

  3. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  4. Invention of a nasolacrimal stent retrieval hook

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; Kim, Yeong Kyun; Park, Sang Soo; Song, Ho Young

    1997-01-01

    To evaluate the clinical usefulness of a nasolacrimal stent retrieval hook The retrieval hook consisted of two parts, a hook and pusher. The head of the hook part was made of 0.7mm stainless steel wire and was question mark-shaped, while the body of this part was constructed by soldering together four stainless steel pipes ranging in thickness from 1.25 to 3.5mm, serially. The pusher part was made of two plastic tubes and was designed in such a way that the hook grasped the stent tightly. The device was used to remove 46 stents in 40 patients, and tested for 1) average number of trials;2) success rate;and 3) average time of the procedure. The average number of trials, success rate, and average time taken to remove the stent was 4.7, 91%, and 1.8 minutes, respectively. In the removal of nasolacrimal stents, the retrieval hook was easy to use, useful and effective

  5. Delayed thrombosis or stenosis following enterprise-assisted stent-coiling: is it safe? Midterm results of the interstate collaboration of enterprise stent coiling.

    Science.gov (United States)

    Mocco, J; Fargen, Kyle M; Albuquerque, Felipe C; Bendok, Bernard R; Boulos, Alan S; Carpenter, Jeffrey S; Fiorella, David J; Hoh, Brian L; Howington, Jay U; Liebman, Kenneth M; Natarajan, Sabareesh K; Rai, Ansaar T; Rodriguez-Mercado, Rafael; Siddiqui, Adnan H; Snyder, Kenneth V; Veznedaroglu, Erol; Hopkins, L Nelson; Levy, Elad I

    2011-10-01

    Stent-assisted coiling of intracranial aneurysms with self-expanding stents has widened the applicability of neuroendovascular therapies to those aneurysms previously considered "uncoilable" because of poor morphology. The Enterprise Vascular Reconstruction Device and Delivery System (Cordis) has demonstrated promising initial short-term results. However, the rates of delayed in-stent stenosis or thrombosis are not known. To report midterm results of the Enterprise stent system. A 10-center registry was created to provide a large volume of data on the safety and efficacy of the Enterprise stent system. Pooled data were compiled for consecutive patients undergoing Enterprise stent-assisted coiling at each institution. Available follow-up data were evaluated for the incidence of in-stent stenosis, thrombosis, and aneurysm occlusion. In total, 213 patients (176 females) with 219 aneurysms were treated with the Enterprise stent. One hundred ten patients had undergone delayed angiography (≥ 30 days from stent placement, mean follow-up 174.6 days). Forty percent of patients demonstrated total occlusion with 88% having ≥ 90% aneurysm occlusion. Six percent of patients had delayed (>30 days) angiographic findings, of which 3% demonstrated significant (≥ 50%) in-stent stenosis or occlusion. Seven delayed thrombotic events occurred (3%), along with 2 additional immediate periprocedural events. All 7 delayed events were concomitant to cessation of double-antiplatelet therapy. Midterm occlusion rates are excellent, and stenosis and thrombosis rates are comparable to other available neurovascular stents. Interruption of antiplatelet therapy appears to be a factor in those developing delayed stenosis or thrombosis.

  6. Heterogeneous Intravascular Ultrasound Findings of Stent Thrombosis

    OpenAIRE

    Morofuji, Toru; Inaba, Shinji; Aisu, Hiroe; Takahashi, Kayo; Saito, Makoto; Higashi, Haruhiko; Yoshii, Toyofumi; Sumimoto, Takumi

    2017-01-01

    Objective The underlying mechanisms of stent thrombosis are not completely understood. Methods We experienced 12 definite stent thrombosis cases (1 early, 1 late, and 10 very late) at our hospital from July 2011 to April 2016 and evaluated the possible causes of stent thrombosis by intravascular ultrasound (IVUS). Results Five different potential morphological causes of stent thrombosis (neoatherosclerosis, stent malapposition, stent fracture, edge dissection, and stent underexpansion) were d...

  7. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    Science.gov (United States)

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  8. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.

    Science.gov (United States)

    de Winter, Robbert J; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A J; Koch, Karel T; Troquay, Roland P T; Hamer, Bas J B; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E Karin; Noutsias, Michel; Ferrari, Markus W; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W

    2018-02-03

    MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45

  9. Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents.

    Science.gov (United States)

    Choi, Woong Gil; Kim, Soo Hyun; Yoon, Hyung Seok; Lee, Eun Joo; Kim, Dong Woon

    2015-01-01

    Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC) capturing stents, by providing a functional endothelial layer on the stent, have beneficial effects on microvascular function. However, data on coronary microvascular function in patients with EPC stents versus DESs are lacking. Seventy-four patients who previously underwent PCI were enrolled in this study. Microvascular function was evaluated 6 months after PCI based on the index of microvascular resistance (IMR) and the coronary flow reserve (CFR). IMR was calculated as the ratio of the mean distal coronary pressure at maximal hyperemia to the inverse of the hyperemic mean transit time (hTmn). The CFR was calculated by dividing the hTmn by the baseline mean transit time. Twenty-one patients (age, 67.2 ± 9.6 years; male:female, 15:6) with an EPC stent and 53 patients (age, 61.5 ± 14.7 years; male:female, 40:13) with second-generation DESs were included in the study. There were no significant differences in the baseline clinical and angiographic characteristics of the two groups. Angiography performed 6 months postoperatively did not show significant differences in their CFR values. However, patients with the EPC stent had a significantly lower IMR than patients with second-generation DESs (median, 25.5 [interquartile range, 12.85 to 28.18] vs. 29.0 [interquartile range, 15.42 to 39.23]; p = 0.043). Microvascular dysfunction was significantly improved after 6 months in patients with EPC stents compared to those with DESs. The complete re-endothelialization achieved with the EPC stent may provide clinical benefits over DESs, especially in patients with microvascular dysfunction.

  10. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Directory of Open Access Journals (Sweden)

    Liberato Manuel José

    2012-08-01

    Full Text Available Abstract Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS and plastic stents (PS.We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS, functional success (FS, early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III. Results The initial stent insertion was successful in 450 (93.8% patients. TS was achieved in 204 (88.3% patients treated with PS and in 246 (98.8% patients palliated with SEMS (p P P  Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients.

  11. Mechanical Properties of Metallic Stents: How Do These Properties Influence the Choice of Stent for Specific Lesions?

    International Nuclear Information System (INIS)

    Dyet, John F.; Watts, William G.; Ettles, Duncan F.; Nicholson, Anthony A.

    2000-01-01

    Purpose: To assess selected balloon-expandable and self-expanding stents for radial force, flexibility, radio-opacity, and trackability, and to relate these physical characteristics to potential indications for placement.Methods: Force-strain curves were plotted for each stent and the force required to produce 50% luminal narrowing was recorded. The ability of the stent to show elastic recoil following deformation was also noted. Flexibility was measured by bending the stents against a force transducer and recording the force required per degree of flexion. Radio-opacity was measured by comparing each stent against a standard aluminum step wedge. Trackability was measured by testing the ability of the stent on its delivery system to track over angles of 90 deg. and 60 deg. Results: The balloon-expandable stents showed greater radial strength and radio-opacity but, apart from the AVE Iliac Bridge stent, showed poorer flexibility and trackability. The self-expanding stents showed less radial force but were able to re-expand following deformity. They were generally more flexible and had better trackability but lower radio-opacity.Conclusion: There is no stent which exhibits all the ideal properties required and therefore the interventionist will need to keep a range of stents available if all lesions are to be addressed

  12. PulmoStent : In Vitro to In Vivo Evaluation of a Tissue Engineered Endobronchial Stent

    NARCIS (Netherlands)

    Thiebes, Anja Lena; Kelly, Nicola; Sweeney, Caoimhe A.; McGrath, Donnacha J.; Clauser, Johanna; Kurtenbach, Kathrin; Gesche, Valentine N.; Chen, Weiluan; Kok, Robbert Jan; Steinseifer, Ulrich; Bruzzi, Mark; O’Brien, Barry J.; McHugh, Peter E.; Jockenhoevel, Stefan; Cornelissen, Christian G.

    Currently, there is no optimal treatment available for end stage tumour patients with airway stenosis. The PulmoStent concept aims on overcoming current hurdles in airway stenting by combining a nitinol stent with a nutrient-permeable membrane, which prevents tumour ingrowth. Respiratory epithelial

  13. Stent migration after right ventricular outflow tract stenting in the severe cyanotic Tetralogy of Fallot case

    Directory of Open Access Journals (Sweden)

    Tamaki Hayashi

    2017-01-01

    Full Text Available We report our experience with a stent migration after right ventricle outflow tract stenting and converted to patent ductus arteriosus stenting in Tetralogy of Fallot (TOF with severe infundibular stenosis. Finally, the patient achieved to TOF repair, and the migrated stent was removed without any complication.

  14. Urethroplasty after Urethral Urolume Stent: an International Multicenter Experience.

    Science.gov (United States)

    Angulo, Javier C; Kulkarni, Sanjay; Pankaj, Joshi; Nikolavsky, Dmitriy; Suarez, Pedro; Belinky, Javier; Virasoro, Ramón; DeLong, Jessica; Martins, Francisco E; Lumen, Nicolaas; Giudice, Carlos; Suárez, Oscar A; Menéndez, Nicolás; Capiel, Leandro; López-Alvarado, Damian; Ramirez, Erick A; Venkatesan, Krishnan; Husainat, Maha M; Esquinas, Cristina; Arance, Ignacio; Gómez, Reynaldo; Santucci, Richard

    2018-05-08

    To evaluate the outcomes and factors affecting success of urethroplasty in patients with stricture recurrence after Urolume® urethral stent. Retrospective international multicenter study on patients treated with urethral reconstruction after Urolume® stent. Stricture and stent length, time between urethral stent insertion and urethroplasty, age, mode of stent retrieval, type of urethroplasty, complications and baseline and post-urethroplasty voiding parameters were analyzed. Successful outcome was defined as standard voiding, without need of any postoperative adjunctive procedure. Sixty-three patients were included. Stent was removed at urethroplasty in 61 patients. Reconstruction technique was excision and primary anastomosis in 14(22.2%), dorsal onlay buccal mucosa graft (BMG) 9(14.3%), ventral onlay BMG 6(9.5%), dorso-lateral onlay BMG 9(14.3%), ventral onlay plus dorsal inlay BMG 3(4.8%), augmented anastomosis 5(7.9%), pedicled flap urethroplasty 6(9.5%), 2-stage procedure 4(6.4%) and perineal urethrostomy 7(11.1%). Success rate was 81% at a mean 59.7+63.4months. Dilatation and/or internal urethrotomy was performed in 10(15.9%), redo-urethroplasty in 5(7.9%). Total IPSS, QoL, Qmax and PVR significantly improved (pUrethroplasty in patients with Urolume® urethral stents is a viable option of reconstruction with a high success rate and very acceptable complication rate. Numerous techniques are viable, however, urethral preservation, tine-by-tine stent extraction and use of BMG augmentation produced significantly better outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Directory of Open Access Journals (Sweden)

    A M den Harder

    Full Text Available Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted.To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children.Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1, placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100% in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis.Median stent lumen visibility was 88 (IQR 86-90% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84% stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm.Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  16. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Science.gov (United States)

    den Harder, A M; Suchá, D; van Hamersvelt, R W; Budde, R P J; de Jong, P A; Schilham, A M R; Bos, C; Breur, J M P J; Leiner, T

    2017-01-01

    Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. Median stent lumen visibility was 88 (IQR 86-90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm). Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  17. Long-term tolerance of airway silicone stent in patients with post-tuberculosis tracheobronchial stenosis.

    Science.gov (United States)

    Verma, Akash; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung; Kim, Hojoong

    2012-01-01

    Surgery is a well-recognized modality of treatment for benign tracheobronchial stenosis. However, in some benign disease groups, such as tuberculosis, sarcoidosis, war gas exposure, and inhalation burns, multiplicity of involvement or long length of stenosed segment heightens surgical challenge. We investigated the outcomes and long-term tolerability of the Natural stent (N-stent) in such patients with post-tuberculosis tracheobronchial stenosis. A retrospective review was done for 17 patients who underwent silicone stenting (N-stent) for post-tuberculosis tracheobronchial stenosis during January 2000-December 2003 but needed persistent stent placement and still require the stent. Significant increase in the ratio of forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC), expressed as FEV1%, as well as in forced percentual vital capacity (FVC%) (Δ24% and Δ11%, respectively) in the short term and sustained increase in the FEV1% and FVC% (Δ26.5% and Δ16.5%, respectively) in the long term were noted at a median (range) interval of 1 (0.5-72) month and 72 (12-114) months, respectively, along with symptomatic relief. No procedure-related death occurred. Stent-related late complications included granulation tissue formation (76%), migration (70%), and mucostasis (17%). The median duration for which N-stents were tolerated was 7.9 (range, 3-11) years. N-stents are well-tolerated for a prolonged period. Stent-related complications occur, but are easily managed. These results might carry medical implications for those who have airway lesions difficult to correct surgically.

  18. Successful stent-in-stent insertion of an expandable metallic stent covered with polyuretane placed to obliterate a large bronchial fistula after chemoradiotherapy for inoperable lung cancer

    International Nuclear Information System (INIS)

    Minami, Hiroya; Tsubota, Noriaki; Miyamoto, Yoshifumi; Yoshimura, Masahiro; Obayashi, Kayoko; Takada, Yoshiki

    1999-01-01

    Bronchial fistulas in cases of inoperable lung cancer caused by radiochemotherapy are quite refractory and generally cannot be surgically closed. A 45-year-old man with squamous cell carcinoma in the right lung underwent two courses of induction chemotherapy (135 mg CDDP, 5 mg VDS, 13.5 mg MMC) and radiation therapy (2 Gy x 22 times) for invasion of the right main bronchus, the pulmonary artery and superior vena cava. Just before the end of the second course, the empyem second to the bronchial fistula caused by tumor necrosis developed in the right upper bronchus, and fenestration was performed. After the operation, his condition improved remarkably, however the fistula enlarged into the right main bronchus and the purulent discharge flowed into the left lung. An expandable metallic stent (EMS) covered with polyuretane was inserted in the trachea and the left main bronchus to break aspiration pneumonia. As the covered EMS was too unstable to be fixed, a bare EMS was inserted in a stent-in-stent fashion. After the procedure he was followed at the O.P.D. and lived a relatively comfortable life for 9 months until his death due to tumor. We inserted the covered EMS in a stent-in-stent fashion to successfully obliterate a large bronchial fistula. (author)

  19. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  20. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  1. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    International Nuclear Information System (INIS)

    Lee, Ye Jin; Kim, Jin Hyoung; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong

    2012-01-01

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10–119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  2. The interventional treatment with two stents in malignant hilar obstruction

    International Nuclear Information System (INIS)

    Gao Kun; Dai Dingke; Zhao Renyou; Qian Xiaojun

    2006-01-01

    Objective: To evaluate the methodology of interventional treatment with two stents in malignant hilar obstructions. Methods: Retrospectively analyzing the two stents, interventional management of unresectable malignant hilar obstruction in 22 patients included unilateral and bilateral puncture routes for placing 'T' shape stent set and 'Y' shape stent set, respectively; together with recording the related complications. Results: The overall technical success rate was 100%, without severe complication. The total serum bilirubin reduced from (337.9 + 81.7) μmol/L before procedure to (129.1 + 51.1) μmol/L after the stent placement. Stent obstruction was found in 8 cases at 6 months; 5 cases by the time of 6-12 months and only 2 cases after 1 year. Conclusion: The method of two stents interventional treatment is a safe and useful management for malignant hilar obstructions. (authors)

  3. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  4. Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

    International Nuclear Information System (INIS)

    Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.

    2011-01-01

    Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

  5. Fully-covered metal stents with endoscopic suturing vs. partially-covered metal stents for benign upper gastrointestinal diseases: a comparative study

    Science.gov (United States)

    Ngamruengphong, Saowanee; Sharaiha, Reem; Sethi, Amrita; Siddiqui, Ali; DiMaio, Christopher J.; Gonzalez, Susana; Rogart, Jason; Jagroop, Sophia; Widmer, Jessica; Im, Jennifer; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Wong, Katherine; Villgran, Vipin; Brewer Gutierrez, Olaya; Bukhari, Majidah; Chen, Yen-I; Hernaez, Ruben; Hanada, Yuri; Sanaei, Omid; Agarwal, Amol; Kalloo, Anthony N.; Kumbhari, Vivek; Singh, Vikesh; Khashab, Mouen A.

    2018-01-01

    Background and study aims  Self-expandable metallic stents (SEMS) have been increasingly used in benign conditions (e. g. strictures, fistulas, leaks, and perforations). Fully covered SEMS (FSEMS) were introduced to avoid undesirable consequences of partially covered SEMS (PSEMS), but come with higher risk of stent migration. Endoscopic suturing (ES) for stent fixation has been shown to reduce migration of FSEMS. Our aim was to compare the outcomes of FSEMS with ES (FS/ES) versus PSEMS in patients with benign upper gastrointestinal conditions. Patients and methods  We retrospectively identified all patients who underwent stent placement for benign gastrointestinal conditions at seven US tertiary-care centers. Patients were divided into two groups: FSEMS with ES (FS/ES group) and PSEMS (PSEMS group). Clinical outcomes between the two groups were compared. Results  A total of 74 (FS/ES 46, PSEMS 28) patients were included. On multivariable analysis, there was no significant difference in rate of stent migration between FS/ES (43 %) and PSEMS (15 %) (adjusted odds ratio 0.56; 95 % CI 0.15 – 2.00). Clinical success was similar [68 % vs. 64 %; P  = 0.81]. Rate of adverse events (AEs) was higher in PSEMS group [13 (46 %) vs. 10 (21 %); P  = 0.03). Difficult stent removal was higher in the PSEMS group (n = 5;17 %) vs. 0 % in the FS/ES group; P  = 0.005. Conclusions  The proportion of stent migration of FS/ES and PSEMS are similar. Rates of other stent-related AEs were higher in the PSEMS group. PSEMS was associated with tissue ingrowth or overgrowth leading to difficult stent removal, and secondary stricture formation. Thus, FSEMS with ES for stent fixation may be the preferred modality over PSEMS for the treatment of benign upper gastrointestinal conditions. PMID:29404384

  6. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  7. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.

    Science.gov (United States)

    Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi

    2016-11-01

    Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.

  8. The forgotten ureteric JJ stent and its prevention: a prospective audit of the value of a ureteric stent logbook.

    Science.gov (United States)

    Thomas, A Z; Casey, R G; Grainger, R; McDermott, T; Flynn, R; Thornhill, J A

    2007-01-01

    Temporary ureteric stent insertion is an integral part of modern endo-urological practice. Delayed stent removal or forgotten stents are associated with increased patient morbidity and complications which are often difficult to manage. We prospectively audited our ureteric stent insertion and removal logbook system to determine the value and effectiveness of our stent follow-up. Over a 1-year period, 210 ureteric stents were inserted in our urological unit. Of these, 47 (22.4%) patients were unaccounted as having their stents removed within the stent logbooks. One patient was lost to follow-up and re-presented with stent encrustation 10 months later. Our results in this audit suggest that our system of ureteric stent follow-up is not effective. We have now introduced a new system that we feel is a safer and a satisfactory alternative to the stent logbooks. This includes a patient education leaflet and removal date scheduling prior to discharge from hospital.

  9. Metallic stents provide better QOL than plastic stents in patients with stricture of unresectable advanced esophageal cancer

    International Nuclear Information System (INIS)

    Ohta, Kazuki; Nagahara, Akihito; Iijima, Katsuyori

    2006-01-01

    The aim of this study was to elucidate the utility and safety of treatment with esophageal stents (plastic and metallic stents) for unresectable advanced esophageal cancer. Between 1992 and 2002, 14 cases of unresectable advanced esophageal cancer were treated with esophageal stents (the plastic stent group, 7 cases; and the metallic stent group, 7 cases). Of these, 10 cases had a history of chemotherapy and or radiotherapy. An improvement in oral intake and performance status (PS), survival time, periods at home, and adverse events were compared between the two groups. After stenting, oral intake and PS were significantly improved in the metallic stent group. Follow-up at home was possible in 71.4%. There was no significant difference in survival or duration of time at home between the two groups. All adverse events were controllable and there was no difference between the two groups. Stenting not only improved oral intake and PS but also allowed a stay at home, resulting in a marked improvement in patients' quality of life (QOL). Stenting was performed safely even in cases with a history of radiotherapy. There was no difference in survival, ratios of staying at home, and safety between the two groups, but QOL was significantly improved in the metallic stent group. These outcomes indicate that placement of metallic stents should be actively considered to treat stricture due to advanced esophageal cancer. (author)

  10. [The thermoformable spiral metallic stents in the treatment of localized ureteral stenosis: an alternative to JJ stent? Prospective multicenter study].

    Science.gov (United States)

    Bonniol, R; Meria, P; Safsaf, A; Albouy, B; Sibert, L

    2011-06-01

    Evaluation of the effectiveness and tolerance of thermoformable metallic spiral stents Memokath(®) 051 (Bard, Pnn Medical) in the treatment of localized ureteral stenosis in non-operable patients who have JJ ureteral stents. Prospective, descriptive and multicenter study of patients with ureteral strictures treated with metallic ureteral stents Memokath(®) 051. Assessment criteria (recurrent stenotic, permeability, tolerance) were measured by clinical, biological and radiological examination at 1 month, and then every 3 months. Fifteen stents (average length: 9.15 cm, range 6-15 cm) were implanted in 14 patients (mean age: 55 years, range: 38-72 years) with secondary suspended ureteral stenosis during 2 years in two centers. The median follow-up was 11 months (range 6 to 24 months). Technical difficulty was observed with two patients. Stents are still up in four patients. The stenosis recurred in four patients with spontaneous progression of stenosis but without endoprosthetics tissue invasion. Two and three migration were observed with spontaneous expulsions. Two lower urinary infections and one high occurred, resolved on antibiotic therapy, no inlay or hematuria, no pain (mean VAS score=3/10) or urinary disorders of the lower unit have been identified. Stents Memokath(®) 051 are well tolered and seem to position themselves as an interesting alternative to JJ ureteral stent in some frails patients. The refinement of contraindication should help to improve the stent's efficacity and to reduce the risk of migration and expulsion. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  11. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  12. Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Thuesen, Leif

    2007-01-01

    pullback recording in the entire length of the artery. METHODS AND RESULTS: In 98 patients with angina pectoris, 1 de novo coronary lesion was treated with a bare-metal stent. After stent implantation, pressure wire measurements (P(d)=mean hyperemic coronary pressure and P(a)=mean aortic pressure) were......-stent restenosis after 9 months. CONCLUSIONS: A residual abnormal P(d)/P(a) distal to a bare-metal stent was an independent predictor of in-stent restenosis after implantation of a coronary bare-metal stent. Udgivelsesdato: 2007-Dec-11......BACKGROUND: Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire...

  13. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Han, Xinwei, E-mail: hanxinwei2006@163.com; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua [The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)

    2016-08-15

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 ± 3.457 and 8.993 ± 0.961 mm; 1 month post-removal; 16.353 ± 4.132 and 8.357 ± 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 ± 2.351 and 2.143 ± 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  14. Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Chul; Jung, Gyoo Sik; Lee, Sang Hee; Kim, Sung Min; Oh, Kyung Seung; Huh, Jin Do; Cho, Young Duk [College of Medicine, Kosin Univ, Pusan (Korea, Republic of); Song, Ho Young [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-04-01

    To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was technically successful in ten patients, and no procedural complications occuured. In one of two patients in whom there was technical failure, and in whom the obstructions were located in part III, the stent was placed transgastrically. Stent migration occurred in one patient four days after the procedure, and treatment involved the palcement of a second, uncovered, nitinol stent. After stent placement, symptoms improved in all patients. During follow-up, obstructive symptoms due to stent stenosis (n=1), colonic obstruction (n=1), and multiple small bowel obstruction (n=1) recurred in three patients. Two of these were treated by placing additional stents in the duodenum and colon, respectively. One of the eight patients in whom a stent was placed in the second portion of the duodenum developed jaundice. The patients died a mean 14 (median, 9) weeks after stent placement. The placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible, safe and effective for the palliative treatment of malignant

  15. Ureteric stent dwelling time: a risk factor for post-ureteroscopy sepsis.

    Science.gov (United States)

    Nevo, Amihay; Mano, Roy; Baniel, Jack; Lifshitz, David A

    2017-07-01

    To evaluate the association between stent dwelling time and sepsis after ureteroscopy, and identify risk factors for sepsis in this setting. The prospectively collected database of a single institution was queried for all patients who underwent ureteroscopy for stone extraction between 2010 and 2016. Demographic, clinical, preoperative and operative data were collected. The primary study endpoint was sepsis within 48 h of ureteroscopy. Logistic regressions were performed to identify predictors of post-ureteroscopy sepsis in the ureteroscopy cohort and specifically in patients with prior stent insertion. Between October 2010 and April 2016, 1 256 patients underwent ureteroscopy for stone extraction. Risk factors for sepsis included prior stent placement, female gender and Charlson comorbidity index. A total of 601 patients had a ureteric stent inserted before the operation and were included in the study cohort, in which the median age was 56 years, 90 patients were women (30%), and 97 patients were treated for positive preoperative urine cultures (16.1%). Postoperative sepsis, Sepsis rates after stent dwelling times of 1, 2, 3 and >3 months were 1, 4.9, 5.5 and 9.2%, respectively. On multivariate analysis, stent dwelling time, stent insertion because of sepsis, and female gender were significantly associated with post-ureteroscopy sepsis in patients with prior stent placement. Patients who undergo ureteroscopy after ureteric stent insertion have a higher risk of postoperative sepsis. Prolonged stent dwelling time, sepsis as an indication for stent insertion, and female gender are independent risk factors. Stent placement should be considered cautiously, and if inserted, ureteroscopy should be performed within 1 month. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  16. Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

    Science.gov (United States)

    Galvin, Emmet; Cummins, Christy; Yoshihara, Shoichiro; Mac Donald, Bryan J; Lally, Caitríona

    2017-08-01

    Magnesium stents are a promising candidate in the emerging field of absorbable metallic stents (AMSs). In this study, the mechanical and corrosion performance of dog-bone specimens and a specific stent design of a magnesium alloy, WE43, are assessed experimentally in terms of their corrosion behaviour and mechanical integrity. It is shown that plastic strains that are induced in the struts of the stent during stent deployment have a critical influence in directing subsequent corrosion behaviour within the material. In addition, the deployment and scaffolding characteristics of the magnesium stent are elucidated and contrasted with those of a commercial stainless steel stent. The magnesium stent is found to support higher levels of cyclic strain amplitude than the stainless steel stent, even prior to degradation, and this may play a role in reducing in-stent restenosis. This study provides new insights into the experimental performance of a current AMS design and material whilst demonstrating the critical influence of plastic strain on the corrosion performance and scaffolding ability of an AMS.

  17. Impact of stent length on clinical outcomes of first-generation and new-generation drug-eluting stents.

    Science.gov (United States)

    Konishi, Hirokazu; Miyauchi, Katsumi; Dohi, Tomotaka; Tsuboi, Shuta; Ogita, Manabu; Naito, Ryo; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Daida, Hiroyuki

    2016-04-01

    The aim of this study is to compare first- and new-generation drug-eluting stents (DESs) which are implanted in long lesion. Stent length is known to be a predictor of adverse events after percutaneous coronary intervention (PCI), even with the first-generation DESs. The introduction of new-generation DESs has reduced the rates of adverse clinical events. However, the impact of stent length on long-term clinical outcomes is not well known. A total of 1181 consecutive patients who underwent PCI using either a first-generation DES (n = 885) or a new-generation DES (n = 296) between 2004 and 2011 were investigated. In each of the stent groups, the patients were divided into two groups by stent length (>32 and ≤32 mm) and compared. During the follow-up period, the incidence of major adverse cardiac events (MACEs) was significantly higher for patients with long stents implanted than with short stents (P stent groups in the new-generation DES group (P = 0.24; log-rank test). On multivariate Cox regression analysis, stent length was not associated with adverse events in the new-generation DES groups [hazard ratio (HR) 0.87; 95 % confidence interval (95 % CI) 0.71-1.04; P = 0.14]. Implanted stent length was significantly associated with a higher risk of MACEs in patients who received first-generation DESs, but not in patients who received the new-generation DESs.

  18. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  19. Evaluation of a novel stent technology: the Genous EPC capturing stent

    NARCIS (Netherlands)

    Klomp, M.

    2012-01-01

    Tegenwoordig gebruiken ziekenhuizen een nieuwe stent bij dotterbehandelingen van kransslagadervernauwingen. Deze Genous-stent heeft een laag met antistoffen waardoor het behandelde bloedvat snel bedekt raakt met lichaamseigen cellen. Zo wordt tegengegaan dat er opnieuw een vernauwing optreedt of dat

  20. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Kaltoft, Anne

    2007-01-01

    OBJECTIVES: The aim of the study was to examine outcomes subsequent to implantation of drug-eluting stents (DES) and bare-metal stents (BMS). BACKGROUND: Use of DES might be associated with increased risk of stent thrombosis (ST), myocardial infarction (MI), and death. METHODS: From January 2002...... through June 2005, data from all percutaneous coronary interventions in western Denmark were prospectively recorded in the Western Denmark Heart Registry; 12,395 consecutive patients (17,152 lesions) treated with stent implantation were followed for 15 months. Data on death and MI were ascertained from...... within 15 months after implantation of DES seems unlikely to outweigh the benefit of these stents. Udgivelsesdato: 2007-Jul-31...

  1. Ureteral in situ biocompatibility of L-lactide-glycolic acid copolymer 80:20 stent

    International Nuclear Information System (INIS)

    Hou Yuchuan; Wang Chunxi; Zhang Baogang; Chen Xuesi

    2006-01-01

    Objective: To evaluate the in situ biocompatibility of a new biodegradable ureteral stent made of L-lactide-glycolic acid copolymer 80:20 (PLGA 80:20). Methods: 16 dogs served as experimental animals. Ureteral stents of PLGA 80:20 were inserted in situ into the left ureter after transection at the mid level, then the ureters were routinely anastomosed. Ureters surrounding the stent were taken out 2, 4, 8 and 12 weeks postoperatively. The ureters were dissected to find changes of stents and local ureters. Histological analysis was performed to investigate tissue reactions to the stent and evaluate the biocompatibility. Rods of UROVISION stent served as controls. Results: The PLGA stent was degraded completely within 12 weeks post implantation. In the early stage (2-4 weeks), both stents induced epithelial hyperplasia and inflammatory cell reaction at local ureter (P>0.05). In the later stage (8-12 weeks), the tissue reaction nearly subsided in PLGA stented ureters after degradation of the device. Whereas, the tissue reaction induced by UROVISION stent had lasted throughout the observation period, even deteriorated with time going (P<0.05). Conclusion: The tissue reaction induced by PLGA stent is retrievable. PLGA is regarded highly compatible and can serve as an ideal material for biodegradable ureteral stent. (authors)

  2. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  3. Gastric and Duodenal Stents: Follow-Up and Complications

    International Nuclear Information System (INIS)

    Pinto Pabon, Isabel Teresa; Paul Diaz, Laura; Ruiz de Adana, Juan Carlos; Lopez Herrero, Julio

    2001-01-01

    Purpose: To assess the efficacy of self-expanding metallic stents in treating inoperable gastric and duodenal stenoses during follow-up and to evaluate the complications encountered.Methods: A total of 31 patients suffering from gastroduodenal obstruction (29 malignant, 2 benign) were treated with a self-expanding metallic stent (Wallstent). In 24 cases insertion was by the peroral route, in seven cases via gastrostomy.Results: All the strictures were successfully negotiated under fluoroscopic guidance without having to resort to endoscopy. A total of 27 patients (87%) were able to resume a regular diet, a soft diet, or a liquid diet orally. Complications included one case of stent malpositioning, one case of leakage of ascitic fluid through the gastrostomy orifice, one case of perforation and fistula to the biliary tree, and two cases of hematemesis. In two patients (6%) additional stents were implanted to improve patency. In all patients follow-up was maintained until death. Recurrence of symptoms immediately before death occurred in seven cases (23%). Mean survival time of patients was 13.3 weeks (SE ± 4.6).Conclusions: The deployment of gastroduodenal stents resulted in good palliation of inoperable gastric and duodenal stenoses. Certain technical aspects, e.g., adaptation of stents to bowel morphology, is critical to proper stent function and avoidance of complications

  4. Tracheal obstruction caused by an expandable metallic stent: a case of successful removal of the stent.

    Science.gov (United States)

    Okuyama, Hiroomi; Kubota, Akio; Kawahara, Hisayoshi; Oue, Takaharu; Nose, Satoko; Ihara, Toshiyuki

    2005-07-01

    We report a case of tracheal obstruction caused by an expandable metallic stent. A 3-month-old girl with severe tracheomalacia had a placement of a Palmaz stent. At 3 years of age, she developed progressive dyspnea. The CT scan showed tracheal obstruction caused by granulation tissue over the stent. At operation, the stent was found to have penetrated the posterior tracheal wall. Under partial cardiopulmonary bypass, the stent was removed along with the membranous wall of the trachea, and the trachea was reconstructed using slide tracheoplasty. Tracheal obstruction is one of the serious complications caused by an expandable metallic stent. Direct open approach to the trachea under cardiopulmonary bypass is thought to be a safe way to manage this problem.

  5. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  6. Percutaneous antegrade ureteric stent removal using a rigid alligator forceps.

    LENUS (Irish Health Repository)

    Given, M F

    2008-12-01

    To evaluate the safety and efficacy of percutaneous antegrade ureteric stent removal using a rigid alligator forceps. Twenty patients were included in our study. Indications for ureteric stent insertion included stone disease (n = 7), malignancy (n = 8) and transplant anastomotic strictures (n = 5). Stent retrieval was carried out for proximal stent placement\\/migration in seven patients and encrustation in the remaining 13. Twenty-two stents were successfully retrieved in 20 patients. There was one technical failure (5%). There were no major complications. We had four minor complications, which included nephrostomy site pain (n = 2), periprocedural sepsis (n = 1) and a small urinoma (n = 1). All patients settled with conservative management. Percutaneous radiologically guided antegrade ureteric stent removal with an alligator forceps is safe and effective, particularly when initial surgical removal has failed.

  7. Introduction of a high-throughput double-stent animal model for the evaluation of biodegradable vascular stents.

    Science.gov (United States)

    Borinski, Mauricio; Flege, Christian; Schreiber, Fabian; Krott, Nicole; Gries, Thomas; Liehn, Elisa; Blindt, Rüdiger; Marx, Nikolaus; Vogt, Felix

    2012-11-01

    Current stent system efficacy for the treatment of coronary artery disease is hampered by in-stent restenosis (ISR) rates of up to 20% in certain high-risk settings and by the risk of stent thrombosis, which is characterized by a high mortality rate. In theory, biodegradable vascular devices exhibit crucial advantages. Most absorbable implant materials are based on poly-L-lactic acid (PLLA) owing to its mechanical properties; however, PLLA might induce an inflammatory reaction in the vessel wall. Evaluation of biodegradable implant efficacy includes a long-term examination of tissue response; therefore, a simple in vivo tool for thorough biocompatibility and biodegradation evaluation would facilitate future stent system development. Rats have been used for the study of in vivo degradation processes, and stent implantation into the abdominal aorta of rats is a proven model for stent evaluation. Here, we report the transformation of the porcine double-stent animal model into the high-throughput rat abdominal aorta model. As genetic manipulation of rats was introduced recently, this novel method presents a powerful tool for future in vivo biodegradable candidate stent biocompatibility and biodegradation characterization in a reliable simple model of coronary ISR. Copyright © 2012 Wiley Periodicals, Inc.

  8. Initial experience with a new biodegradable airway stent in children: Is this the stent we were waiting for?

    Science.gov (United States)

    Antón-Pacheco, Juan L; Luna, Carmen; García, Enrique; López, María; Morante, Rocío; Tordable, Cristina; Palacios, Alba; de Miguel, Mónica; Benavent, Isabel; Gómez, Andrés

    2016-06-01

    To report our experience with a new type of biodegradable airway stent in the setting of severe tracheobronchial obstruction in children. We conducted a retrospective and prospective (since June 2014) study of pediatric patients with severe airway obstruction treated with biodegradable stents in our institution between 2012 and 2015. The following data were collected: demographics, indication for stenting, bronchoscopic findings, insertion technique complications, clinical outcome, stent related complications, re-stenting, and time of follow-up. Thirteen custom-made polydioxanone stents were placed in four infants (mean age, 4 months) with severe tracheobronchial obstruction: tracheomalacia (two patients), bronchomalacia (1), and diffuse tracheal stenosis (1). All the stents were bronchoscopically inserted uneventfully. Immediate and maintained clinical improvement was observed in every case. No major stent related complications have occurred and only mild or moderate granulation tissue was observed during surveillance bronchoscopy. Two patients required repeated stenting as expected. All the patients are alive and in a good respiratory condition with a follow-up ranging from 5 to 40 months. Biodegradable airway stents seem to be safe, effective, and cause fewer complications than other types of stents. They can be an alternative to the classic metallic or plastic stents for severe tracheal stenosis or malacia in small children. More experience is needed in order to establish the definite clinical criteria for their use in pediatric patients. Pediatr Pulmonol. 2016;51:607-612. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  10. Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    Science.gov (United States)

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori; Tsuchida, Akihiko

    2011-01-01

    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 ± 71.5 d vs 166.2 ± 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. PMID:21677835

  11. Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

    International Nuclear Information System (INIS)

    Wang Zhongmin; Huang Xunbo; Cao Jun; Huang Gang; Chen Kemin; LIu Yu; Liu Fenju

    2012-01-01

    Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

  12. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  13. The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.

    Science.gov (United States)

    Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu

    2018-02-01

    In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  15. DNA and Flavonoids Leach out from Active Nuclei of Taxus and Tsuga after Extreme Climate Stresses

    Directory of Open Access Journals (Sweden)

    Walter Feucht

    2015-09-01

    Full Text Available Severe over-stresses of climate caused dramatic changes in the intracellular distribution of the flavonoids. This was studied in needles from the current year’s growth of the following species and varieties: Tsuga canadensis, Taxus baccata, T. aurea, T. repens, T. nana, and T. compacta. The mode of steady changes in flavonoids was evaluated by microscopic techniques. Most of the flavonoids stain visibly yellow by themselves. The colorless flavanol subgroup can be stained blue by the DMACA reagent. In mid-summer 2013, outstanding high temperatures and intense photo-oxidative irradiation caused in a free-standing tree of Taxus baccata dramatic heat damage in a limited number of cells of the palisade layers. In these cells, the cytoplasm was burned brown. However, the nucleus maintained its healthy “blue” colored appearance which apparently was a result of antioxidant barrier effects by these flavanols. In late May 2014, excessive rainfall greatly affected all study trees. Collectively, in all study trees, a limited number of the mesophyll nuclei from the needless grown in 2013 and 2014 became overly turgid, enlarged in size and the flavanols leached outward through the damaged nuclear membranes. This diffusive stress event was followed one to three days later by a similar efflux of DNA. Such a complete dissolution of the nuclei in young tissues was the most spectacular phenomenon of the present study. As a common feature, leaching of both flavanols and DNA was markedly enhanced with increasing size and age of the cells. There is evidence that signalling flavonoids are sensitized to provide in nuclei and cytoplasm multiple mutual protective mechanisms. However, this well-orchestrated flavonoid system is broken down by extreme climate events.

  16. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  17. Long term follow-up of bifurcation aneurysms treated with braided stent assisted coiling and complex T- and Y- stent constructs.

    Science.gov (United States)

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D

    2018-06-01

    Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    International Nuclear Information System (INIS)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  19. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2014-02-15

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  20. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  1. A computational study of crimping and expansion of bioresorbable polymeric stents

    Science.gov (United States)

    Qiu, T. Y.; Song, M.; Zhao, L. G.

    2017-10-01

    This paper studied the mechanical performance of four bioresorbable PLLA stents, i.e., Absorb, Elixir, Igaki-Tamai and RevaMedical, during crimping and expansion using the finite element method. Abaqus CAE was used to create the geometrical models for the four stents. A tri-folded balloon was created using NX software. For the stents, elastic-plastic behaviour was used, with hardening implemented by considering the increase of yield stress with the plastic strain. The tri-folded balloon was treated as linear elastic. To simulate the crimping of stents, a set of 12 rigid plates were generated around the stents with a radially enforced displacement. During crimping, the stents were compressed from a diameter of 3 mm to 1.2 mm, with the maximum stress developed at both inner and outer sides of the U-bends. During expansion, the stent inner diameter increased to 3 mm at the peak pressure and then recoiled to different final diameters after balloon deflation due to different stent designs. The maximum stress was found again at the U-bends of stents. Diameter change, recoiling effect and radial strength/stiffness were also compared for the four stents to assess the effect of design variation on stent performance. The effect of loading rate on stent deformation was also simulated by considering the time-dependent plastic behaviour of polymeric material.

  2. Percutaneous Biliary Drainage Using Open Cell Stents for Malignant Biliary Hilar Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sun Jun; Bae, Jae Ik; Han, Tae Sun; Won, Je Hwan; Kim, Ji Dae; Kwack, Kyu Sung; Lee, Jae Hee; Kim, Young Chul [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2012-11-15

    To evaluate the feasibility, safety and the effectiveness of the complex assembly of open cell nitinol stents for biliary hilar malignancy. During the 10 month period between January and October 2007, 26 consecutive patients with malignant biliary hilar obstruction underwent percutaneous insertion of open cell design nitinol stents. Four types of stent placement methods were used according to the patients' ductal anatomy of the hilum. We evaluated the technical feasibility of stent placement, complications, patient survival, and the duration of stent patency. Bilobar biliary stent placement was conducted in 26 patients with malignant biliary obstruction-T (n = 9), Y (n 7), crisscross (n = 6) and multiple intersecting types (n = 4). Primary technical success was obtained in 24 of 26 (93%) patients. The crushing of the 1st stent during insertion of the 2nd stent occurred in two cases. Major complications occurred in 2 of 26 patients (7.7%). One case of active bleeding from hepatic segmental artery and one case of sepsis after procedure occurred. Clinical success was achieved in 21 of 24 (87.5%) patients, who were followed for a mean of 141.5 days (range 25-354 days). The mean primary stent patency period was 191.8 days and the mean patient survival period was 299 days. Applying an open cell stent in the biliary system is feasible, and can be effective, especially in multiple intersecting stent insertions in the hepatic hilum.

  3. Percutaneous Biliary Drainage Using Open Cell Stents for Malignant Biliary Hilar Obstruction

    International Nuclear Information System (INIS)

    Ahn, Sun Jun; Bae, Jae Ik; Han, Tae Sun; Won, Je Hwan; Kim, Ji Dae; Kwack, Kyu Sung; Lee, Jae Hee; Kim, Young Chul

    2012-01-01

    To evaluate the feasibility, safety and the effectiveness of the complex assembly of open cell nitinol stents for biliary hilar malignancy. During the 10 month period between January and October 2007, 26 consecutive patients with malignant biliary hilar obstruction underwent percutaneous insertion of open cell design nitinol stents. Four types of stent placement methods were used according to the patients' ductal anatomy of the hilum. We evaluated the technical feasibility of stent placement, complications, patient survival, and the duration of stent patency. Bilobar biliary stent placement was conducted in 26 patients with malignant biliary obstruction-T (n = 9), Y (n 7), crisscross (n = 6) and multiple intersecting types (n = 4). Primary technical success was obtained in 24 of 26 (93%) patients. The crushing of the 1st stent during insertion of the 2nd stent occurred in two cases. Major complications occurred in 2 of 26 patients (7.7%). One case of active bleeding from hepatic segmental artery and one case of sepsis after procedure occurred. Clinical success was achieved in 21 of 24 (87.5%) patients, who were followed for a mean of 141.5 days (range 25-354 days). The mean primary stent patency period was 191.8 days and the mean patient survival period was 299 days. Applying an open cell stent in the biliary system is feasible, and can be effective, especially in multiple intersecting stent insertions in the hepatic hilum.

  4. A Multidisciplinary Approach on the Perioperative Antithrombotic Management of Patients With Coronary Stents Undergoing Surgery: Surgery After Stenting 2.

    Science.gov (United States)

    Rossini, Roberta; Tarantini, Giuseppe; Musumeci, Giuseppe; Masiero, Giulia; Barbato, Emanuele; Calabrò, Paolo; Capodanno, Davide; Leonardi, Sergio; Lettino, Maddalena; Limbruno, Ugo; Menozzi, Alberto; Marchese, U O Alfredo; Saia, Francesco; Valgimigli, Marco; Ageno, Walter; Falanga, Anna; Corcione, Antonio; Locatelli, Alessandro; Montorsi, Marco; Piazza, Diego; Stella, Andrea; Bozzani, Antonio; Parolari, Alessandro; Carone, Roberto; Angiolillo, Dominick J

    2018-03-12

    Perioperative management of antithrombotic therapy in patients treated with coronary stents undergoing surgery remains poorly defined. Importantly, surgery represents a common reason for premature treatment discontinuation, which is associated with an increased risk in mortality and major adverse cardiac events. However, maintaining antithrombotic therapy to minimize the incidence of perioperative ischemic complications may increase the risk of bleeding complications. Although guidelines provide some recommendations with respect to the perioperative management of antithrombotic therapy, these have been largely developed according to the thrombotic risk of the patient and a definition of the hemorrhagic risk specific to each surgical procedure, key to defining the trade-off between ischemia and bleeding, is not provided. These observations underscore the need for a multidisciplinary collaboration among cardiologists, anesthesiologists, hematologists and surgeons to reach this goal. The present document is an update on practical recommendations for standardizing management of antithrombotic therapy management in patients treated with coronary stents (Surgery After Stenting 2) in various types of surgery according to the predicted individual risk of thrombotic complications against the anticipated risk of surgical bleeding complications. Cardiologists defined the thrombotic risk using a "combined ischemic risk" approach, while surgeons classified surgeries according to their inherent hemorrhagic risk. Finally, a multidisciplinary agreement on the most appropriate antithrombotic treatment regimen in the perioperative phase was reached for each surgical procedure. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    Directory of Open Access Journals (Sweden)

    Geanina Onuta

    2011-01-01

    Full Text Available Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s of long-term autoimmune diabetes on development of in-stent restenosis. We here describe the development of in-stent restenosis in long-term (~7 months spontaneously diabetic and age-matched, thymectomized, nondiabetic Diabetes Prone BioBreeding (BBDP rats (n=6-7 in each group. Diabetes was suboptimally treated with insulin and was characterized by significant hyperglycaemia, polyuria, proteinuria, and increased HbA1c levels. Stented abdominal aortas were harvested 28 days after stenting. Computerized morphometric analysis revealed significantly increased neointima formation in long-term diabetic rats compared with nondiabetic controls. In conclusion, long-term autoimmune diabetes in BBDP rats enhances in-stent restenosis. This model can be used to study the underlying pathogenetic mechanisms of diabetes-enhanced in-stent restenosis as well as to test new therapeutic modalities.

  6. Current state of the absorbable metallic (magnesium) stent.

    Science.gov (United States)

    Waksman, Ron

    2009-12-15

    BIOTRONIK's absorbable metal stent technology is based ona magnesium alloy that offers superior stent mechanics and biocompatibility. The first generation (AMS-1) showed promising results regarding mechanical properties as well as feasibility and safety in several human applications (150 cases). The second generation (AMS-2.1) shows improved scaffolding and efficacy in animals due to a more slowly degrading magnesium alloy and an optimised stent design. The preclinical results of the drug-eluting AMS-3 are encouraging and the clinical investigational program will resume in 2010.

  7. Expansion characteristics of coronary stents in focal stenoses

    Directory of Open Access Journals (Sweden)

    Schmidt Wolfram

    2017-09-01

    Full Text Available The presented experimental in vitro approach was designed to assess the expansion behavior of stent systems in a resistant focal stenosis model with respect to a potential dog-boning effect. Five different stent systems (nominal diameter 3.0 mm were investigated. The focal stenosis was simulated by a stainless steel tube (ID ≤ 1.20 mm. Stent expansion was performed using a proprietary test device consisting of a test chamber with 37 °C water, 2-axis laser scanner and a pressure controller.

  8. Assessment of Vascular Stent Heating with Repetitive Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Varnerin, Nicole; Mirando, David; Potter-Baker, Kelsey A; Cardenas, Jesus; Cunningham, David A; Sankarasubramanian, Vishwanath; Beall, Erik; Plow, Ela B

    2017-05-01

    A high proportion of patients with stroke do not qualify for repetitive transcranial magnetic stimulation (rTMS) clinical studies due to the presence of metallic stents. The ultimate concern is that any metal could become heated due to eddy currents. However, to date, no clinical safety data are available regarding the risk of metallic stents heating with rTMS. We tested the safety of common rTMS protocols (1 Hz and 10 Hz) with stents used commonly in stroke, nitinol and elgiloy. In our method, stents were tested in gelled saline at 2 different locations: at the center and at the lobe of the coil. In addition, at each location, stent heating was evaluated in 3 different orientations: parallel to the long axis of coil, parallel to the short axis of the coil, and perpendicular to the plane of the coil. We found that stents did not heat to more than 1°C with either 1 Hz rTMS or 10 Hz rTMS in any configuration or orientation. Heating in general was greater at the lobe when the stent was oriented perpendicularly. Our study represents a new method for ex vivo quantification of stent heating. We have found that heating of stents was well below the Food and Drug Administration standards of 2°C. Thus, our study paves the way for in vivo testing of rTMS (≤10 Hz) in the presence of implanted magnetic resonance imaging-compatible stents in animal studies. When planning human safety studies though, geometry, orientation, and location relative to the coil would be important to consider as well. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. Metallic stent for the treatment of iliac arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1993-07-15

    In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.

  10. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2014-01-01

    We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.

  11. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    Science.gov (United States)

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  12. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    Science.gov (United States)

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  13. Biodegradable Stents for Caustic Esophageal Strictures: Do They Work?

    Science.gov (United States)

    Kochhar, Rakesh; Samanta, Jayanta; Basha, Jahangeer; Verma, Abhai; Choudhuri, Gourdas; Lakhtakia, Sundeep; Reddy, D Nageshwar

    2017-08-01

    Biodegradable (BD) stents have been used for the management of various esophageal strictures (ES) but the experience of its use in caustic strictures is limited. The present study, aimed at evaluating efficacy of BD stents for the treatment of refractory caustic-induced ES, was a retrospective multi-center study conducted at three tertiary care centers in India wherein adult patients with refractory caustic induced strictures underwent placement of a BD stent. Patients were followed up for immediate complications and long term outcome. All 13 patients (39.3 ± 15.1 years) underwent successful BD stent placement. Retrosternal chest pain occurred in 2 patients and stent migration in 1 (7.6%) patient. At 3 months, restenosis with recurrence of dysphagia was seen in nine (69.2%) patients, at 6 months, 10 (77%) patients had dysphagia of whom three underwent surgery and the remaining seven patients required dilatations. At 1 year, one patient remained asymptomatic while nine had dysphagia. The requirement for dilatation was once in 3 months in seven patients & once in a month in two patients. At 2 years, the requirement of dilatations was further reduced to once in 4-6 months in all patients. Over a 3 year follow up three (23%) patients had undergone surgery, one was free of symptoms while nine patients continued to be on periodic dilatation although the requirement had reduced to once in 4-6 months. Efficacy of BD stents in patients with caustic-induced ES is limited and the short term radial force applied by the currently available BD stents is inadequate to provide long term relief in such patients.

  14. Association of localized hypersensitivity and in-stent neoatherosclerosis with the very late drug-eluting stent thrombosis.

    Directory of Open Access Journals (Sweden)

    Kyohei Yamaji

    Full Text Available Localized hypersensitivity reaction, delayed arterial healing, and neoatherosclerosis inside the stent have been suggested as the underlying pathologic mechanisms of very late stent thrombosis (VLST of drug-eluting stent (DES. The present study sought to explore the prevalence of inflammatory cell infiltrates and evidence for fragments of atherosclerotic plaques in the aspirated thrombi in patients with DES VLST.From April 2004 to September 2012, 48 patients with stent thrombosis (ST of DES underwent thrombus aspiration with retrieved material sufficient for the histopathologic analysis; early ST (EST, within 30 days: N = 17, late ST (LST, between 31 and 365 days: N = 7, and very late ST (VLST, >1 year: N = 24. Eosinophil fraction in the aspirated thrombi was significantly higher in patients with VLST (8.2±5.7% as compared with those with EST (4.3±3.0% and LST (5.5±3.8% (P = 0.03. Eosinophil fraction in the aspirated thrombi was significantly higher in 12 VLST patients with angiographic peri-stent contrast staining (PSS and/or incomplete stent apposition (ISA by intravascular ultrasound than in 12 VLST patients without PSS or ISA (10.6±6.1% versus 5.8±4.1%, P = 0.03. Evidences for fragments of atherosclerotic plaques in the aspirated thrombi were observed only in 3 (13% out of 24 patients with DES VLST.Eosinophil fraction in the aspirated thrombi was significantly higher in patients with DES VLST as compared with those with EST and LST. Evidences for fragments of atherosclerotic plaques were relatively uncommon in patients with DES VLST.

  15. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  16. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  17. Early and mid-term results with the Growth Stent--a possible concept for transcatheter treatment of aortic coarctation from infancy to adulthood by stent implantation?

    Science.gov (United States)

    Ewert, Peter; Peters, Bjoern; Nagdyman, Nicole; Miera, Oliver; Kühne, Titus; Berger, Felix

    2008-01-01

    Evaluation of the Growth Stent-a stent consisting of two stent halves connected by reabsorbable sutures-for the treatment of aortic coarctation in infants. Surveillance study of 13 Growth Stents implanted in 12 patients aged 1-15 months (median 5 months). Body weight ranged from 3.4-12.8 kg (median 5.4 kg). Eight patients suffered from aortic (re-)coarctation, four of them from stenosis of the aortic anastomosis after a Norwood I procedure. The follow-up period was 24 months (11-51 months). Pressure gradients immediately after stent implantation decreased from 30 mm Hg (range 20-50 mm Hg) to 8 mm Hg (range 0-15 mm Hg). Five patients had one (3 pts) or two (2 pts) balloon dilations 3-28 months (median 12 months) after Growth Stent implantation. The median pressure gradient decreased from 25 mm Hg (range 15-30 mm Hg) to 15 mm Hg (range 5-25 mm Hg). Six patients received a large stent after 19-34 months. Median body weight was 11.8 kg (9.4-15 kg). The Growth Stent is suitable for the acute treatment of aortic coarctation in infants and can be overstented later on--if necessary--with a larger stent without causing restriction. Copyright 2008 Wiley-Liss, Inc.

  18. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  19. [Internal drainage in cancer patients: optimizing treatment of stent-related symptoms].

    Science.gov (United States)

    Martov, A G; Ergakov, D V; Novikov, A B; Muzhetskaya, N G; Esen'yan, G L

    2016-04-01

    The so-called stent-related symptoms caused mainly by detrusor overactivity due to distal ("cystic") curl of the internal stent are common among patients with this type of drainage. The need for long-term stenting makes the quality of life of cancer patients one of the challenging problems of modern urology. The aim of this study was to optimize treatment of stent-related symptoms in cancer patients with internal long-term stents by complementing the treatment regimen with m-anticholinergic solifenacin. From November 2013 to November 2015 68 cancer patients (26 males, 42 females, age 36-79 years) underwent elective internal ureteral stenting for drainage of the upper urinary tract (UUT) with special long-term stents coated with the hydrogel. The urinary tract obstruction was caused by urological (24), gynecological (26) and colorectal (18) cancers. Before deciding on urinary tract drainage, all patients were treated with radiation or chemotherapy, 28 (41.2%) patients underwent surgery, but on admission all of them had contraindications to radical surgery for different reasons. In 52 (76.5%) patients UUT stenting was performed using transurethral access, in 12 (17.6%) by percutaneous access and in another 4 (5.9%) by the combined access with patients in the supine position. Percutaneous and combined access was used in cases of impracticability (failure) of transurethral stenting. Patients in group 1 (n=32) after stent placement received standard therapy co-administered with solifenacin 5 mg daily, group 2 (n=36) - only standard therapy. The data analyzed were the technical features of the internal drainage, optimal access and registered solifenacin-related adverse events. Control examinations were scheduled once in 3 months after stent placement according to the following algorithm: ultrasound scanning, laboratory test monitoring and, if indicated, plain urography. To objectify the severity of stent-related symptoms, a survey of patients using a special

  20. Treatment of esophagopleural fistulas using covered retrievable expandable metallic stents.

    Science.gov (United States)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Kyung Rae; Park, Jung-Hoon; Kim, Jin Hyoung; Song, Ho-Young

    2014-04-01

    To evaluate the clinical efficacy of placement of covered retrievable expandable metallic stents for esophagopleural fistulas (EPFs). During the period 1997-2013, nine patients with EPF were treated using covered retrievable expandable metallic stents. The underlying causes of EPF were esophageal carcinoma (n = 6), lung cancer (n = 2), and postoperative empyema for Boerhaave syndrome (n = 1). Technical success was achieved in eight patients (88.9%). In one patient, incomplete EPF closure was due to incomplete stent expansion. Clinical success, defined as complete EPF closure within 7 days, was achieved in five patients (55.6%). Overall fistula persistence (n = 1) or reopening (n = 4) occurred in five patients (55.6%) 0-15 days after stent placement. The causes of reopening were due to the gap between the stent and the esophagus (n = 3) or stent migration (n = 1). For fistula persistence or reopening, additional interventional management, such as gastrostomy, stent removal, or stent reinsertion, was performed. Stent migration occurred as a complication in one patient with EPF from a benign cause secondary to postoperative empyema. In the eight patients who died during the follow-up period, the mean and median survival times were 78.8 days and 46 days, respectively. Placement of a covered expandable metallic esophageal stent for the palliative treatment of EPF is technically feasible, although the rate of clinical success was poor secondary to fistula persistence or reopening. Fistula reopening was caused by the gap between the stent and the esophagus or by stent migration, and additional interventional treatment was useful to ensure enteral nutritional support. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  1. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  2. Novel 3D-CT evaluation of carotid stent volume: greater chronological expansion of stents in patients with vulnerable plaques.

    Science.gov (United States)

    Itami, Hisakazu; Tokunaga, Koji; Okuma, Yu; Hishikawa, Tomohito; Sugiu, Kenji; Ida, Kentaro; Date, Isao

    2013-09-01

    Although self-expanding carotid stents may dilate gradually, the degrees of residual stenosis have been quantified by the NASCET criteria, which is too simple to reflect the configuration of the stented artery. We measured the volumes of the stent lumens chronologically by 3D-CT in patients after carotid artery stenting (CAS), and analyzed the correlations between the volume change and medical factors. Fourteen patients with carotid artery stenosis were treated using self-expanding, open-cell stents. All patients underwent preoperative plaque MRI (magnetization-prepared rapid acquisition gradient-echo, MPRAGE) and chronological 3D-CT examinations of their stents immediately after their placement and 1 day, 1 week, and 1 month after the procedure. The volume of the stent lumen was measured using a 3D workstation. The correlations between stent volume and various factors including the presence of underlying diseases, plaque characteristics, and the results of the CAS procedure were analyzed. Stent volume gradually increased in each case and had increased by 1.04-1.55 (mean, 1.25)-fold at 1 postoperative month. The presence of underlying medical diseases, plaque length, the degree of residual stenosis immediately after CAS, and plaque calcification did not have an impact on the change in stent volume. On the other hand, the stent volume increase was significantly larger in the patients with vulnerable plaques that demonstrated high MPRAGE signal intensity (P stent volume. Self-expanding stents in carotid arteries containing vulnerable plaques expand significantly more than those without such plaques in a follow-up period.

  3. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  4. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  5. Self-made metal stent in treatment of nasolacrimal duct obstruction

    International Nuclear Information System (INIS)

    Du Wei; Pang Ruilin; Luo Gang; Gu Jingchuan; Gong Yongxiang

    2003-01-01

    Objective: To evaluate application of self-made metal stent in treatment of nasolacrimal duct obstruction. Methods: In total 15 cases, self-made metal stents made of stainless steel wire were implanted in 18 obstructed nasolacrimal ducts. The lacrimal passages were rinsed and re-canalized followed by antegrade inserting the guide wire from upper dacryon. A dilator was inserted over the guide wire, and then a stent was released from a sheath into the impaired section of nasolacrimal duct. Dacryocystography was performed before and after the interventional procedure. Results: Dacryocystography showed patent nasolacrimal duct after treatment. Epiphora disappeared completely in 11 cases (13 ducts), improved in 4 cases (5 ducts). These cases had been followed up for 61-219 days (167 days in average). Relapse was found in 2 cases (2 ducts) in three months. Those 2 stents were removed by surgical procedure and found occluded by granulation. Conclusion: Interventional placement of the self-made metal stent is a simple, safe, low-cost and effective treatment of the nasolacrimal duct obstruction

  6. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    Science.gov (United States)

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (pstent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

    Science.gov (United States)

    Lansky, Alexandra J; Kastrati, Adnan; Edelman, Elazer R; Parise, Helen; Ng, Vivian G; Ormiston, John; Wijns, William; Byrne, Robert A

    2016-02-15

    We compared the outcomes of a novel, thin-strut, cobalt-chromium, absorbable, polymer sirolimus-eluting stent (APSES; MiStent) to the durable polymer cobalt-chromium everolimus-eluting stent (EES; Xience). A propensity-matched analysis was performed comparing data from the DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesions in the Native Coronary Arteries (DESSOLVE) I and II studies, evaluating the APSES to the EES arm of the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents-4 study. Target lesion failure (TLF) and its components were evaluated at 12 months and annually to 3 years; 805 patients (APSES = 153; EES = 652) were included with propensity matching in 204 patients (APSES = 102; EES = 102). APSES compared with EES had lower TLF at 1 year (3.0% vs 8.0%, p = 0.12) driven by a difference in target lesion revascularization (TLR; 1% vs 6%, p = 0.05), with no difference in target vessel myocardial infarction (p = 0.56) or stent thrombosis (p = 0.31). At 3 years, TLF (5.0% vs 12.5%, p = 0.07) and TLR (2.0% vs 8.4%, p = 0.04) remained lower with APSES. By landmark analysis, there was no significant difference in TLF between 1 and 3 years (p = 0.36). In conclusion, in a propensity-matched analysis, the APSES demonstrated reduced clinically indicated TLR rates at 1 and 3 years compared with the durable polymer EES, with minimal accrual of events between 1 and 3 years. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

    Science.gov (United States)

    Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C

    2005-02-01

    Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact

  10. Retreatment of recanalized aneurysms after Y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature.

    Science.gov (United States)

    Kono, Kenichi; Shintani, Aki; Terada, Tomoaki

    2014-01-01

    It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.

  11. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  12. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    OBJECTIVES: This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. BACKGROUND: The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing...... the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  13. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  14. Endobronchial Occlusion Stent: A Preliminary Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yo Won; Jeong, Woo Kyoung; Lee, Seoung Hoon; Heo, Jeong Nam; Jeon, Seok Chol [Hanyang University College of Medicine, Seoul (Korea, Republic of); Ko, Gi Young; Song, Ho Young [University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2010-04-15

    To evaluate the safety and the technical feasibility of the use of an endobronchial occlusion stent and to get preliminary data for the development of the optimal material required for endobronchial occlusions. A commercialized, self-expandable tracheobronchial stent was modified; one half had a polyurethane cover with an occluded end and the other half was uncovered with a flaring configuration. The occluded end was placed such that it would face the distal lung. Under fluoroscopic guidance, seven stents were placed at the lower lobar bronchus in 6 mini-pigs. The bronchial obstruction was examined immediately after stent placement. Chest radiographs were taken at days 1, 7, 14, and 28 after stent placement and the removed airways from two, two, one, and one mini-pigs sacrificed on corresponding days were examined for the maintenance of bronchial obstruction. Stents were successfully placed and induced the immediate bronchial obstruction in all mini-pigs. Five of seven airways with occlusion stents maintained an obstruction until the mini-pigs were sacrificed. Proximal stent migration occurred in two mini-pigs (29%), and pulmonary consolidations were observed distal to four of the stents (57%). The placement of an endobronchial occlusion stent and the obstruction of targeted bronchi seem to be feasible, but an add-on check valve should be considered to prevent stent migration and obstructive pneumonia

  15. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  16. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    International Nuclear Information System (INIS)

    Wang Zhongmin; Chen Kemin; Gong Ju; Zheng Yunfeng; Wang Tianxiang

    2009-01-01

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4

  17. Carotid Angioplasty and Stenting

    Science.gov (United States)

    Carotid angioplasty and stenting Overview Carotid angioplasty (kuh-ROT-id AN-jee-o-plas-tee) and stenting ... to better see and examine the blood vessels. Food and medications You'll receive instructions on what ...

  18. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.

  19. Budd-Chiari syndrome due to prothrombotic disorder: mid-term patency and efficacy of endovascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Pelage, Jean-Pierre; Denys, Alban; Sibert, Annie; Menu, Yves [Department of Radiology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Valla, Dominique [Department of Hepatology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Sauvanet, Alain; Belghiti, Jacques [Department of Surgery, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France)

    2003-02-01

    Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients. (orig.)

  20. Stone Formation and Fragmentation in Forgotten Ureteral Double J Stent

    Directory of Open Access Journals (Sweden)

    Okan Bas

    2014-02-01

    Full Text Available Aim: Nowadays, ureteral stents play an essential role in various endourological and open surgical procedures and common procedures performed in daily urological practice. However, stents can cause significant complications such as migration, infection, fragmentation, stone formation and encrustation, especially when forgotten for a long period. Objectives: We present our experience in endoscopic management of forgotten ureteral stents with a brief review of current literature. Case presentation: A total of 2 patients with forgotten ureteral stents were treated with endourological approaches in our department. Indwelling durations were 18 months and 36 months. After treatment both patients were stone and stent free. Conclusion: An endourological approach is effective for stent and stone removal after a single anesthesia session with minimal morbidity and short hospital stay. However, therapeutic strategy is also determined by the technology available. The best treatment would be the prevention of this complication by providing detailed patient education.

  1. The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.

    Science.gov (United States)

    Lee, Stephen W L; Tam, Frankie C C; Lam, Simon C C; Kong, Shun-Ling; Shea, Catherine P; Chan, Kelvin K W; Wong, Michael K L; Chan, Michael P H; Wong, Anthony Y T; Yung, Arthur S Y; Lam, Yui-Ming; Zhang, Lei-Wei; Wu, Karl K Y; Mintz, Gary S; Maehara, Akiko

    2018-04-01

    Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months ( P <0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1-100) versus 99.6% (interquartile range, 96.8-99.9; difference, 0.10; 95% confidence interval, 0.00-1.05; P <0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small

  2. Indications for stenting during thrombolysis

    DEFF Research Database (Denmark)

    Bækgaard, N; Broholm, R; Just, Sven Richardt Lundgren

    2013-01-01

    of a stent in this position is the treatment of choice facilitating the venous flow into an unobstructed outflow tract either from the femoral vein or the deep femoral vein or both. The stent, made of stainless steel or nitinol, has to be self-expandable and flexible with radial force to overcome...... the challenges in this low-pressure system. The characteristics of the anatomy with external compression and often a curved vein segment with diameter difference make stent placement necessary. Ballooning alone has no place in this area. The proportion of inserted stents varies in the published materials...

  3. Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting Stents

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Christiansen, Evald Høj

    2016-01-01

    BACKGROUND: Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown. OBJECTIVES: This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical...... rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR...... in Non-selected Patients With Coronary Heart Disease [SORT OUT IV]; NCT00552877)....

  4. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  5. Tamsulosin, Solifenacin, and Their Combination for the Treatment of Stent-Related Symptoms: A Randomized Controlled Study.

    Science.gov (United States)

    Dellis, Athanasios E; Papatsoris, Athanasios G; Keeley, Francis X; Bamias, Aristotelis; Deliveliotis, Charalambos; Skolarikos, Andreas A

    2017-01-01

    To properly use the Ureteric Symptom Score Questionnaire (USSQ) to evaluate, in a randomized control study, the effect of tamsulosin, solifenacin, and their combination in improving symptoms and quality of life in patients with indwelling ureteral stents. After institutional review board approval, 260 patients with a ureteral stent were randomly assigned to receive tamsulosin 0.4 mg, solifenacin 5 mg, or placebo and further randomized to receive their combination. The validated USSQ was completed 1 and 4 weeks after stent insertion and 4 weeks after stent removal. Kruskal-Wallis test, chi-squared test (or Fisher's exact test), one-way analysis of variance, and T-test (or Wilcoxon rank-sum test if not normal data) were used for statistical analysis. The results were considered significant at p tamsulosin or solifenacin expressed significantly lower urinary (p tamsulosin and solifenacin alone or in combination, improves stent-related symptoms and has a positive impact on quality of life.

  6. Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.

    Science.gov (United States)

    Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K

    2016-07-01

    Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. The use of balloon-expandable metallic stents in the treatment of pediatric tracheomalacia and bronchomalacia.

    Science.gov (United States)

    Furman, R H; Backer, C L; Dunham, M E; Donaldson, J; Mavroudis, C; Holinger, L D

    1999-02-01

    To evaluate the use of balloon-expandable metallic stents in the treatment of children with tracheomalacia and bronchomalacia in whom conventional therapy has failed. Retrospective case series. Tertiary pediatric otolaryngology and cardiothoracic surgery referral center. Six patients were identified as having undergone bronchoscopic placement of metallic balloon-expandable stents between 1994 and 1997. The age at stent placement, prior surgical interventions, and indications for and sites of stent placement were noted. Also, the complications related to stent placement and the current airway status of the patients were reviewed. Twelve balloon-expandable metallic angioplasty stents (Palmaz; Johnson & Johnson Interventional Systems Co, Warren, NJ) were placed bronchoscopically in 6 patients. Six stents were placed in the lower trachea, and 6 were placed in the main bronchi. The stents were balloon expanded under fluoroscopic guidance. Discontinuation of mechanical ventilation. The age at stent placement ranged from 1.5 to 38 months (mean age at placement, 10 months). The indications for stent placement were (1) tracheomalacia or bronchomalacia, (2) pericardial patch or slide tracheoplasty failure, and (3) bronchomalacia caused by tetralogy of Fallot and large pulmonary arteries. The primary complication of stent placement was postoperative granulation tissue formation. One patient required the removal of 2 tracheal stents because of granulation tissue formation. There were 2 deaths in the series, 1 possibly related to stent placement. Four of the 6 patients were weaned from mechanical ventilation, and 3 experienced prolonged relief of airway obstruction. Metallic balloon-expandable stents are effective in relieving lower tracheomalacia and bronchomalacia in select patients. Only patients in whom conventional therapy has failed should be considered for stent placement.

  8. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.

    Science.gov (United States)

    Kaiser, Christoph; Galatius, Soeren; Jeger, Raban; Gilgen, Nicole; Skov Jensen, Jan; Naber, Christoph; Alber, Hannes; Wanitschek, Maria; Eberli, Franz; Kurz, David J; Pedrazzini, Giovanni; Moccetti, Tiziano; Rickli, Hans; Weilenmann, Daniel; Vuillomenet, André; Steiner, Martin; Von Felten, Stefanie; Vogt, Deborah R; Wadt Hansen, Kim; Rickenbacher, Peter; Conen, David; Müller, Christian; Buser, Peter; Hoffmann, Andreas; Pfisterer, Matthias

    2015-01-06

    Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. © 2014 American Heart Association, Inc.

  9. Characterization of micro-invasive trabecular bypass stents by ex vivo perfusion and computational flow modeling

    Directory of Open Access Journals (Sweden)

    Hunter KS

    2014-03-01

    Full Text Available Kendall S Hunter,1 Todd Fjield,2 Hal Heitzmann,2 Robin Shandas,1 Malik Y Kahook3 1Department of Bioengineering, University of Colorado Denver, Aurora, CO, USA; 2Glaukos Corporation, Laguna Hills, CA, USA; 3University of Colorado Hospital Eye Center, Aurora, CO, USA Abstract: Micro-invasive glaucoma surgery with the Glaukos iStent® or iStent inject® (Glaukos Corporation, Laguna Hills, CA, USA is intended to create a bypass through the trabecular meshwork to Schlemm's canal to improve aqueous outflow through the natural physiologic pathway. While the iStent devices have been evaluated in ex vivo anterior segment models, they have not previously been evaluated in whole eye perfusion models nor characterized by computational fluid dynamics. Intraocular pressure (IOP reduction with the iStent was evaluated in an ex vivo whole human eye perfusion model. Numerical modeling, including computational fluid dynamics, was used to evaluate the flow through the stents over physiologically relevant boundary conditions. In the ex vivo model, a single iStent reduced IOP by 6.0 mmHg from baseline, and addition of a second iStent further lowered IOP by 2.9 mmHg, for a total IOP reduction of 8.9 mmHg. Computational modeling showed that simulated flow through the iStent or iStent inject is smooth and laminar at physiological flow rates. Each stent was computed to have a negligible flow resistance consistent with an expected significant decrease in IOP. The present perfusion results agree with prior clinical and laboratory studies to show that both iStent and iStent inject therapies are potentially titratable, providing clinicians with the opportunity to achieve lower target IOPs by implanting additional stents. Keywords: glaucoma, iStent, trabecular bypass, intraocular pressure, ab-interno, CFD

  10. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P; Lackner, K [Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik; Goetz, R [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  11. Utility of MR cholangiography for follow-up examination after metallic stent placement in the bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Hi; Yang, Dal Mo; Kim Hak Soo; Cho, Seung Whi; Kim, Hyung Sik; Jin Wook; Hwang, Hee Young [Gachon Medical College Gil Medical Center, Incheon (Korea, Republic of)

    2002-09-01

    To evaluate the efficacy of MR cholangiography for follow-up examination after metallic stent placement in the bile duct. Between December 1999 and June 2000, 15 patients with biliary obstruction in whom metallic biliary stents had been placed underwent MR cholangiography during follow-up examination. The causes of obstruction were hilar cholangiocarcinoma (n=6), common bile duct cancer (n=5), gall bladder cancer (n=1) and pancreatic cancer (m=3). The types of self-expandable metallic stent employed were the nitinol stent (n=2), the endocoil nitinol stent (n=3), the ultraflexed diamond stent (n=5), and the wallstent (n=5). Using MR cholangiography, we measured the diameter of that part of the biliary stent which showed high signal intensity, assigning one point if this was less than one third of the stent diameter, two points of between one third and two thirds, and three points if more than two thirds. We decided that a higher score indicated fewer artifacts. The score was 1.7-3 (mean, 2.3) points for the endocoil nitinol stent, 1.7-2.3 (mean, 2) for the nitinol stent, and 1-3 (mean, 1.7) for the ultraflex diamond stent. In most cases, two thirds of the stent diameter was observed. For the wallstent, the score was 1-1.7 (mean, 1.3) points and the inner portion of the stent was almost invisible. MR cholangiography is not useful for follow-up examination after the placement of wallstents and three other types of nitinol stent in the bile duct.

  12. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    Science.gov (United States)

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  13. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1994-07-15

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed.

  14. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    Science.gov (United States)

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  15. Use of retrievable self-expanding stent in treating childhood benign oesophageal stricture

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhu Ming

    2007-01-01

    Objective: To evaluate the methods and effect of retrievable self-expanding esophageal stent in treating benign esophageal stenosis of children. Methods: The covered retrievable expandable nitinol stents were placed in 10 children with corrosive esophageal stenosis and post-anastomotic stenosis, age ranged from 2 to 12 years, the dysphagia scores were 3, Barium esophagography was taken before the use of retrievable stent. Results: The stents were placed safely in all patients without complications and were successfully removed after all. After the stent placement, all patients could take solid food without dysphagia. During 6 to 12 months follow-up after the stent removal, all children could eat satisfactorily with the dysphagia score as 0. Conclusion: The use of covered retrievable expandable stent is effective and safe in treating childhood benign esophageal stenosis. (authors)

  16. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  17. Outcomes of endoscopically inserted self-expandable metal stents in malignancy according to the type of stent and the site of obstruction.

    Science.gov (United States)

    Jung, Kyoungwon; Ahn, Ji Yong; Jung, Hwoon-Yong; Cho, Charles J; Na, Hee Kyong; Jung, Kee Wook; Lee, Jeong Hoon; Kim, Do Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Kim, Jin-Ho

    2016-09-01

    Self-expandable metal stents (SEMSs) can be used for the palliation of malignant obstruction in the upper gastrointestinal tract. This study assessed the feasibility and efficacy of endoscopically inserted SEMSs for the palliation of malignant obstruction in the stomach and duodenum. Between January 2011 and April 2014, 220 patients with gastric or duodenal obstruction due to malignancy underwent endoscopic SEMS insertion at Asan Medical Center. The associations of technical/clinical outcomes and complications with the type of stent and site of obstruction were analyzed. The 220 patients included 125 men (56.8 %) and 95 women (43.2 %); median patient age was 63 years. Fully covered, partially covered, and uncovered SEMSs were inserted into 16, 77, and 120 patients, respectively. Obstructions were located in the gastric outlet, including the duodenal bulb, in 106 patients, and in the duodenal second and third portions in 114 patients. Technical success was achieved in 213 of 220 patients (96.8 %) and clinical success in 184 of 213 (86.4 %). Clinical success rates were similar to the type of stent, but were significantly greater for gastric outlet (95/104, 91.3 %) than for duodenal (89/109, 81.7 %) obstructions (p = 0.039). Stent migration was observed in 20 patients (9.1 %) and stent obstruction in 51 (23.2 %). Rates of stent migration were significantly higher for fully covered (6/16, 37.5 %) than for partially covered (7/77, 9.1 %) and uncovered (7/120, 5.8 %) SEMSs (p stent obstruction were similar for fully covered (2/16, 12.5 %), partially covered (17/77, 22.1 %), and uncovered (32/120, 26.7 %) SEMSs (p = 0.409) and in patients with gastric outlet (26/104, 25.0 %) and duodenal (25/109, 22.9 %) obstruction (p = 0.724). SEMS selection for malignant obstruction of the upper gastrointestinal tract depends on the site of obstruction.

  18. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  19. Primary antegrade ureteric stenting: Prospective experience and cost-effectiveness analysis in 50 ureters

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Gillian M.T.; Patel, Uday

    2001-07-01

    AIM: To evaluate the success rate and cost efficiency of primary antegrade ureteric stenting (antegrade ureteric stent insertion as a single procedure without preliminary drainage). MATERIALS AND METHODS: A policy of primary stenting was tested in 38 patients (50 ureters) with obstructive hydronephrosis, of acute or chronic onset and of benign or malignant origin. Patients with suspected pyonephrosis were excluded. Patients successfully primarily stented (group 1) were compared to a group stented as a traditional two-stage procedure (group 2). End point assessments were screening time, equipment used, procedure-related costs, bed occupancy and technical and clinical success rate. Using these cost and outcome measures, a cost-efficiency analysis was performed comparing the two strategies. RESULTS: 40/50 (80%) ureters were considered primary stent successes. The average procedure-related bed occupancy was 2 days (range 1-2 days). Simple equipment alone was successful in 16 cases. Van Andel dilatation catheters and peel-away sheaths were frequently used (23 ureters). Expensive equipment was rarely necessary (four cases) and average extra equipment cost was small (46 pounds/case). The mean screening time was similar for the two groups (13.5 min vs 15.3 min;P {>=} 0.05). There was a minimum saving of 800 pounds per successful primary stent. The cost-effectiveness of a primary antegrade stenting strategy was 1229 pounds vs 2093 pounds for secondary stenting. CONCLUSION: In carefully selected patients, the majority of obstructed ureters can be primarily stented using simple equipment. The reduced hospital stay and overall success rate significantly improves the cost competitiveness of antegrade ureteric stenting. Watson, G.M.T. and Patel, U. (2001)

  20. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  1. Investigation of adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents in the iliac vein: insights into developing a better iliac vein stent.

    Science.gov (United States)

    Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-06-01

    We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.

  2. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  3. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  4. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    Science.gov (United States)

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to

  5. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  8. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  9. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  10. A shape memory airway stent for tracheobronchomalacia in children: an experimental and clinical study.

    Science.gov (United States)

    Tsugawa, C; Nishijima, E; Muraji, T; Yoshimura, M; Tsubota, N; Asano, H

    1997-01-01

    The authors have designed a coil airway stent using a thermal shape-memory titanium-nickel alloy (SMA) to relieve airway collapse in children. A characteristic of alloy allowed the stent to be enclosed in the thin introducer tube and to position it bronchoscopically in the collapsed airway. When the stent is warmed to 37 to 40 degrees C, it expands to the memorized diameter and stents the airway. In eight rabbits, an experimental model of potentially fatal tracheomalacia was created by fracturing the tracheal cartilages. The stents of 6 mm in diameter and 15 mm in length were placed, and then the stents were recovered to their original shape within 1 minute. All rabbits except one showed no respiratory symptoms during the follow-up period. Results of bronchoscopy performed 6 and 10 months after implantation showed satisfactory patency of the trachea. The rabbits were killed for histological evaluation 6 to 28 months after implantation. The specimens showed little proliferation of granulation and no dislodgement of the stents. This procedure was attempted in two children who had severe bronchomalacia. One 5-year-old patient underwent implantation with a stent of 5 mm in diameter and 25 mm in length into the left main bronchus. The patient was relieved from apneic attacks. The stent was removed 2 years after implantation after a remarkable improvement of ventilation. The other patient with left bronchomalacia, age 1 year 2 months, underwent implantation with a 5-mm x 20-mm stent. The animal experiment and clinical experience indicated that (1) this stent can be easily inserted and removed bronchoscopically, (2) the stent has good tissue compatibility and little interference of mucociliary function, and (3) the SMA stent is a promising therapeutic adjunct in the management of children with severe tracheobronchomalacia.

  11. Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla

    International Nuclear Information System (INIS)

    Reinhardt, Julia; Fachhochschule Jena; Nguyen-Trong, Thien-Hoa; Haehnel, Stefan; Bellemann, Matthias E.; Heiland, Sabine; Neurologische Universitaetsklinik Heidelberg

    2009-01-01

    The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within the tube and within the stent. The stents made of stainless steel and cobalt alloy displayed severe susceptibility artifacts. Therefore the vessel lumen within the stent could not be assessed. The nitinol stents showed different artifact patterns: The AccuLink and DynaLink stents showed less artifacts compared to the Xact and Protoge stents. Besides the susceptibility artifacts we found artifacts due to RF shielding by the stent mesh, particularly in TSE sequences. A MR control of patients after stenting is possible and may yield diagnostic information when using the AccuLink or DynaLink stents. However, it is important to make sure that the stent is MR safe for the field strength used for the examination. (orig.)

  12. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  13. Self-expendable metallic stents for palliative treatment of malignant esophagogastric strictures: experiences in 103 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah; Do, Young Soo; Lee, Byung Hee; Oh, Hoon Il; Kim, Soo Ah; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the effects and complication of self-expandable metallic stent for the treatment of malignant esophagogastric strictures. From September 1991 to March 1995, 110 stents were placed under fluoroscopic guidance in 103 patients. Of the 103 patients, there were 73 patients with esophageal cancer, 14 patients with gastric cancer, 12 patients with recurrence after surgery, three patients with esophageal compression by metastatic mediastinal lymphadenopathy, and one patient with esophageal invasion by lung cancer. Seventeen patients had esophagorespiratory fistulas. Under fluoroscopic guidance, 113 self-expandable metallic stents (99 Song stents, 14 Strecker stents) were placed in 103 patients. After stent placement, 68 (66%) of the patients could ingest solid food, 26 (25.2%) could ingest soft food whereas three (2.9%) were not able to have food. Esophagorespiratory fistulas were occluded immediately after stent insertion. All stents were placed without any technical failures or procedural morbidity or mortality. Complications included restenosis in 13, gastroesophageal reflux in 11, stent tube migration in eight, massive bleeding in four, delayed esophageal perforation in one, stent obstruction by food impaction in one patient. Self-expandable metallic stent seems to be relatively safe and effective procedure in the palliative treatment of malignant esophagogastric stricture.

  14. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  15. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  16. Temporary urethral covered stent - third year of experience

    International Nuclear Information System (INIS)

    Stojanovis, V.; Maksimovis, H.; Markovis, B.; Markovis, Z.

    2006-01-01

    Full text: In October 2003, a new generation of urethral stents ALLIUM, produced in Israel, were used at the Department of Interventional Radiology, CCS, in 18 patients with chronic stricture of bulbar urethra. The indications for insertion were determined according to well-known and recognized therapeutical protocols. The stent is made of nitinol wire with polyurethane cover. It is inserted under local anesthesia by a special self-expandable system that may be fixed or flexible. The stents we used were 3-6 cm long and 28 Fr wide. Radioscopic-assisted insertion was performed over formerly placed metal guide. Prior to insertion, balloon-catheter dilatation of stricture matching the stent width was carried out. Pre-insertion urethrotomy was performed in one case. The insertion technique is simple, presupposing the knowledge of older generations of techniques of urethral dilatation and insertion of self-expandable stents. The follow-up of results was done according to a priori established protocol including the following: UCG, uroflowmetry and interview with patients. Due to stent migration, the 'stent over stent' technique was applied in one case, while reposition by balloon-catheter outward traction was performed in two cases of caudal migration. No irritative discomforts were reported in the first 4 months after stent dwelling. Uroflowmetric controls verified at least four times better results than before the insertion. Given it is the question of covered stent, there is no possibility of proliferative secondary lumen obstruction. On account of soft structure and conic shape of posterior part of stent, no lesions of the external urethral sphincter were manifested. The stent is simply withdrawn after 6 months by outward traction using the forceps at the time when the stent construction turns into soft and straight wire. The first clinical experiences are very favorable and ALLIUM stent may be expected to be the stent of choice for chronic bulbar strictures

  17. The effect of stent structure changes on the hemodynamics and the formation of in-stent restenosis

    International Nuclear Information System (INIS)

    Wu Xia; Xu Ke; Xiao Liang; Zhang Xitong; Su Hongying; Feng Bo

    2009-01-01

    Objective: To investigate the effect of stent structure changes on the formation of in-stent restenosis by studying the influence of these changes on the shear force to the vascular wall, on the velocity of flow and on the flow pattern. Methods: Five stent models were established by using Pro/engineer wildfire 3.0. Model A was regarded as control structure. On the base structure of model A, transverse link component was added to form model B, and vertical link component was added to form model C. The thickness of model D was twice than that of model A, and the meshes density of model E was twice than that of model A. Fluid models were built up by importing these stent models into computational fluid dynamics (CFD) software ansys11.0-CFX, then, CFD analysis was proceeded to study the effect of stent structure on hemodynamics. Results: After the stents were implanted, the percentage of low wall shear stress on the surface of model A, B, C, D and E was 7.78%, 6.65%, 1.48%, 16.52% and 12.12%, respectively. The percentage of D and E was obviously larger than that of A, while the percentage of B was markedly smaller than that of A. The velocity vector on the cross-sectional planes showed that the low velocity and eddy areas in D and E were much larger than that in A, while this area in C was smaller than that in A. Conclusion: The stent structure changes can cause obvious changes in hemodynamics in the implanted vessels. The increase in the thickness and meshes density of the stent is the main factor that induces the formation of low wall shear stress, which will precipitate the development of in-stent restenosis. The added vertical link component will reduce the area of low wall shear stress as well as the occurrence of in-stent restenosis. (authors)

  18. Gianturco-Rösch Z stents in tracheobronchial stenoses.

    Science.gov (United States)

    Petersen, B D; Uchida, B T; Barton, R E; Keller, F S; Rösch, J

    1995-01-01

    To evaluate expandable metallic Gianturco-Rösch Z (GRZ) stents for treatment of benign and malignant tracheobronchial stenoses. Six patients, ages 45-73 years, were treated for severe dyspnea with placement of GRZ stents. Three patients had benign tracheal lesions (one tracheomalacia, two postoperative) and received uncovered GRZ stents. Three patients had malignant stenoses at the level of the carina; one received an uncovered stent and the other two received silicone-covered GRZ stents. Two patients with benign lesions responded well to stent placement. One was asymptomatic for a year and then was lost to follow-up; the other improved substantially but died of end-stage lung disease 5 months after stent placement. A third patient with a benign high tracheal lesion did poorly; symptoms recurred secondary to inferior migration of a stent, which was removed surgically at 4 months. All patients with malignant lesions improved symptomatically after stent placement and remained without significant dyspnea until death (from 1 to 6 months). Expandable GRZ stents are promising devices for treatment of benign lesions and offer effective palliation of malignant tracheobronchial stenoses.

  19. PTA and stenting for various types of Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Zhang Xinbao

    2011-01-01

    Objective: To investigate and evaluate PTA and stenting for various types of Budd-Chiari syndrome (BCS). Methods: 89 patients with BCS were diagnosed and treated during 7 years. The interventional procedures included: Percutaneous balloon dilatation (PBD) of inferior vena cava (IVC), PBD and stent placement for IVC, hepatic vein angioplasty via trans jugular vein, hepatic vein angioplasty via transhepatic and trans jugular approach, accessory hepatic vein angioplasty, percutaneous dual balloon dilatation for IVC and hepatic vein, and percutanous dual stent placement for IVC and hepatic vein. Results: The achievement ratio of PTA and stent placement was 96% and the mortality was 0%. The serious complication of PTA and stent placement of BCS was penetration into the pericardium, endovascular stent migration into right atrium. Conclusion: 1. PTA is a reliable procedures in treating type I a, II and III BCS, and TIPPS is useful for type I b BCS. But PTA and stenting is necessary for patients with type IV BCS. 2. Thrombolysis is needed for patients with type III, IV BCS. 3. Guiding of Color Doppler Ultrasound can improve the success of percutanous hepatic vein and reduce complications. (authors)

  20. Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori

    2014-01-01

    -treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0 ± 7.2 in BES- and 39.6 ± 25.2 in BMS-treated lesions (P segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued...

  1. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  2. Physical property and MR imaging of self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Kang, Sung Gwon; Cho, Young Kook; Kim, Hyung Jin; Lim, Myung Kwan; Cho, Soon Gu; Yoh, Kyu Tong; Suh, Chang Hae [Inha Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    In order to furnish basic information prior to their use, the physical properties of various self-expandable metallic stents and their MR characteristics were evaluated. Four commercially available self-expandable metallic stents-Gianturco-the Rosch, Hanaro, Memotherm, and Wallstent-were used in this study. For evaluation of the physical properties of each, hoop strengths and changes in radii according to the degrees of longitudinal flexion were compared. Stent characteristics seen on MR images were evaluated by measuring magnetic torque and by comparing images obtained in the vascular phantom using SE T1TI, FSE T2WI, and FMPSPGR sequences. These images were analyzed with special emphasis on artifact size and the apparant shepe of the stent. Hoop strength was greatest in the Gianturco-Rosch stent, followed by the Memotherm, Hanaro, and Wallstent. When flexed in the longitudinal axis, the radius of the Hanaro and Memotherm stent decreased slightly as a larger flexion angle was applied. When this was 90 deg, however, the connection of the Gianturco-Rosch stent collapsed. In contrast, the radius of the Wallstent became larger as a larger flexion angle was applied. At the portal of the MR imaging unit, neither the Memotherm nor Wallstent showed deflection; except for a thin hyperintense rim at both ends, their images were excellent, and the lumina of these stents were also clearly seen. In contrast, the Gianturco-Rosch and Hanaro stent demonstrated large deflexion and showed a severe black-hole artifact. As a result, visualization of the stents themselves and their lumina was impossible. The Gianturco-Rosch stent showed greatrer hoop strength than the others. The Wallstent showed good longitudinal flexibility and was thought to be effective in tortuous vessels. For follow-up after placement, especially when the nonferromagnetic Memotherm and Wallstent are used, MR imaging appears to be safe and useful.=20.

  3. Direct coronary stenting in reducing radiation and radiocontrast consumption

    International Nuclear Information System (INIS)

    Caluk, Jasmin; Osmanovic, Enes; Barakovic, Fahir; Kusljugic, Zumreta; Terzic, Ibrahim; Caluk, Selma; Sofic, Amela

    2010-01-01

    Coronary stenting is the primary means of coronary revascularization. There are two basic techniques of stent implantation: stenting with balloon predilatation of stenosis and stenting without predilatation (direct stenting). Limiting the time that a fluoroscope is activated and by appropriately managing the intensity of the applied radiation, the operator limits radiation in the environment, and this saves the exposure to the patient and all personnel in the room. Nephrotoxicity is one of the most important properties of radiocontrast. The smaller amount of radiocontrast used also provides multiple positive effects, primarily regarding the periprocedural risk for the patients with the reduced renal function. The goal of the study was to compare fluoroscopy time, the amount of radiocontrast, and expenses of material used in direct stenting and in stenting with predilatation. In a prospective study, 70 patients with coronary disease were randomized to direct stenting, or stenting with predilatation. Fluoroscopy time and radiocontrast use were significantly reduced in the directly stented patients in comparison to the patients stented with balloon-predilatation. The study showed a significant reduction of expenses when using a direct stenting method in comparison to stenting with predilatation. If the operator predicts that the procedure can be performed using direct stenting, he is encouraged to do so. Direct stenting is recommended for all percutaneous coronary interventions when appropriate conditions have been met. If direct stenting has been unsuccessful, the procedure can be converted to predilatation

  4. Scintigraphic examinations after stent implantation in central airways; Szintigraphische Untersuchungen bei Stents in den zentralen Atemwegen

    Energy Technology Data Exchange (ETDEWEB)

    Richter, W.S.; Kettner, B.I.; Munz, D.L. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Charite, Medizinische Fakulteat der Humboldt-Univ. zu Berlin (Germany)

    1998-03-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [Deutsch] Die endotracheale und -bronchiale Stentimplantation wurde in den letzten Jahren als effektive Massnahme bei benignen und malignen Stenosen der Atemwege, drohendem Atemwegsverschluss und bei tracheo- bzw. bronchooesophagealen Fisteln eingefuehrt. Der gewaehlte Stenttyp richtet sich nach dem Implantationsort und den krankheitsbedingten Veraenderungen. Zum Monitoring von Lage, Struktur und Funktion eines Stents dienen Thoraxroentgenaufnahmen und die Bronchoskopie. Nuklearmedizinische Verfahren koennen nicht-invasiv den Effekt der Stenteinlage auf Lungenventilation und -perfusion belegen. Die Validierung des Effekts einer Stentimplantation auf die mukoziliaere und tussive Clearance steht noch aus. (orig.)

  5. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  6. Comparative analysis of intraluminal radiation stent in treatment of advanced esophageal carcinoma

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; He Shicheng; Fang Wen; Deng Gang; Li Guozhao

    2007-01-01

    Objective: To compare the clinical effectiveness of intraluminal radiation stent with that of common covered stent to palliate dysphagia in advanced esophageal cancer. Methods: Fifty three cases were randomly assigned to the experimental group (Group A, n=27) and the control group (Group B, n26). Radiation stents were placed in Group A and common covered stents were placed in Group B. A randomized trial was performed to compare the two groups with respect to complications, relief of dysphagia, and overall survival period. Results: The placement of stents were successful in all the 53 patients. In Group A, no leakage of radiation source was observed through ECT examination, and no displacement of radiation seeds was found through radiography. The follow-up CT showed reduced lesion size compared to presurgical lesion. Three of the 5 patients who underwent uncovered radiation stent placement showed complete necrosis and inflammatory hyperblastosis in tumor tissue adjacent to radiation particles at 2 months follow-up. The lumen of the stents were smooth and had no overgrowth of tumor tissue. Granulation hyperplasia was found at both ends of the stents, prominent at the proximal ends, The incidence of stent- related complications had no significant difference between group A and group B (test, P>0.05). Dysphasia resolved significantly after stent placement in both groups. The improvement of dysphasia was more significant in Group A than in Group B after 2 months of stent placement (1.37±0.56 in group A, 1.82±0.50 in group B,P=0.004). The median survival period was longer in Group A than in Group B (7 months vs 4 months ). The mean survival period was also longer in Group A than in Group B (8.3 months vs 3.5 months). There was a statistically significant difference in the survival period between the two groups (P<0.01). Conclusion: Intraluminal radiation esophageal stent can not only palliate dysphagia but also restrain tumor growth. Palliation period of dysphagia and

  7. The use of expandable metallic airway stents for tracheobronchial obstruction in children.

    Science.gov (United States)

    Filler, R M; Forte, V; Fraga, J C; Matute, J

    1995-07-01

    Expandable metallic angioplasty stents (Palmaz stent) have been implanted in the trachea and/or bronchi of seven children. Three children had severe tracheal stenosis after tracheoplasty for congenital tracheal stenosis repair, and four had tracheomalacia or bronchomalacia with or without vascular compression. The mean age at stenting was 9.7 months (range, 2 to 15 months). Balloon expandable stents were inserted into the trachea or bronchus through a 3.5-mm bronchoscope under fluoroscopic control. Initially a single tracheal stent was used for all patients except for one with obstruction in the trachea and both bronchi, in whom three stents were implanted. Three children had recurrent airway obstruction 1 month later; one was cured with a second stent; one child died 1 year later; and the other is being treated for heart disease. The others have no serious respiratory problems. The stents in all have been in place for 1 to 25 (mean, 11) months. No immediate complications were noted. Early and late bronchoscopy showed incomplete epithelialization of the stent and patches of granulation tissue on it. Two stents were removed bronchoscopically, one at the completion of treatment for tracheomalacia and the other at the time of recurrent airway obstruction. This preliminary experience indicates that expandable metallic stents have a useful role in the treatment of selected lower airway obstructions.

  8. Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: Angiographic and case-by-case review of 1,800 PCIs.

    Science.gov (United States)

    Arnous, Samer; Shakhshir, Nizar; Wiper, Andrew; Ordoubadi, Farzin-Farth; Williams, Paul; Clarke, Bernard; Mahadavan, Vaikom; El-Omar, Magdi; Mamas, Mamas; Fraser, Douglas

    2015-11-15

    There is conflicting evidence regarding the incidence of longitudinal stent deformation (LSD) in contemporary practice. To assess the incidence and mechanism of LSD across commonly used DES platforms, we performed a case-by-case review of 1,800 PCI cases involving 450 consecutive procedures using Biomatrix Flex, Resolute Integrity, Promus Element, and Xience V stents, respectively, between January 2009 and December 2011. LSD was detected in a higher proportion with Promus Element [15 (3.1%)] compared with other platforms (Xience V [4 (0.9%)], Biomatrix [3 (0.7%)], Resolute [3 (0.7%)]; P = 0.002). LSD was characterized as guide catheter/guide extension induced, or as impact from secondary devices such as postdilatation balloons or IVUS catheters. The incidence of guide catheter/guide extension LSD was similar across platforms; (Promus Element [5 (1.1%)], Xience V [4 (0.9%)], Biomatrix [3 (0.7%)], Resolute [3 (0.7%)]; P = 0.85). Secondary device LSD occurred exclusively with Promus Element (9/450 cases [2%] (P stent was more difficult in cases of secondary device LSD (6/9 compared with 0/12 treated cases; P stent (OR 5.53 CI[1.54-19.85]), Guideliner use (OR 22.09 CI[4.73-103]), postdilation balloons (OR 5.47 CI[1.31-22.81]) and number of stents deployed (OR 2.06 CI[1.45-2.9]. LSD is more common than previously reported. LSD by a guide catheter/guide extension occurred equally with all platforms, however, LSD associated with secondary devices only occurred with the Element stent. These findings have important implications regarding current and future stent designs. © 2015 Wiley Periodicals, Inc.

  9. Clinical application of the Natural Y stent in the management of benign carinal stenosis.

    Science.gov (United States)

    Nam, Hae-Seong; Um, Sang Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung; Kim, Jhingook; Kim, Hojoong

    2009-08-01

    The Y-shaped structure of the carinal bifurcation causes difficulties in the treatment of carinal stenosis. We describe a new Y-shaped silicone stent, called the Natural Y stent. We investigated its clinical efficacy through a review of patients with benign carinal stenosis who undewent consecutive Natural Y stent placement. Between January 2004 and February 2008, 11 patients underwent ballooning, neodymium:yttrium-aluminum-garnet laser resection, or bougienation (by rigid bronchoscopy) to dilate the airway, followed by placement of the Natural Y stent. The underlying etiologies of carinal stenosis included posttuberculosis stricture in 7 patients (64%), postintubation stenosis in 2 (18%), and postoperative malacia in 2 (18%). All patients reported subjective symptomatic relief immediately after stent placement. No procedurally related deaths or immediate major complications occurred. Stent-related late complications included granulation tissue formation (64%) and mucostasis (18%, defined as > or = 50% narrowing). The median duration of overall stent placement was 439 days (range, 119 to 1729 days). The stents were successfully removed in 4 patients (36%) after a median of 409 days. The Natural Y stent provides an effective and feasible therapeutic modality in patients with benign carinal stenosis, with or without previous thoracic airway interventions.

  10. Basic Knowledge about Metal Stent Development

    Directory of Open Access Journals (Sweden)

    Seok Jeong

    2016-03-01

    Full Text Available Biliary self-expandable metal stents (SEMS, a group of non-vascular stents, have been used in the palliative management of biliary obstruction around the world. However, there are still unmet needs in the clinical application of biliary SEMS. Comprehensive understanding of the SEMS is required to resolve the drawbacks and difficulties of metal stent development. The basic structure of SEMS, including the materials and knitting methods of metal wires, covering materials, and radiopaque markers, are discussed in this review. What we know about the physical and mechanical properties of the SEMS is very important. With an understanding of the basic knowledge of metal stents, hurdles such as stent occlusion, migration, and kinking can be overcome to develop more ideal SEMS.

  11. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  12. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  13. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  14. Strategy for optimal side-branch positioning of bioresorbable vascular scaffolds in dedicated 2-stent techniques: Insights from optical coherence tomography

    International Nuclear Information System (INIS)

    Miyazaki, Tadashi; Costopoulos, Charis; Sato, Katsumasa; Naganuma, Toru; Panoulas, Vasileios F.; Figini, Filippo; Latib, Azeem; Colombo, Antonio

    2014-01-01

    We present a case of a left anterior descending artery/diagonal branch bifurcation successfully treated with a dedicated 2-stent technique utilizing bioresorbable vascular scaffolds, where the bifurcation angle did not strictly allow a T-stenting approach. We also propose a strategy to avoid or reduce scaffold overlap in the main branch, especially important in view of the bulkier size of these novel devices

  15. Mechanistic, Mutational, and Structural Evaluation of a Taxus Phenylalanine Aminomutase

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lei; Wanninayake, Udayanga; Strom, Susan; Geiger, James; Walker, Kevin D. (MSU)

    2014-10-02

    The structure of a phenylalanine aminomutase (TcPAM) from Taxus canadensis has been determined at 2.4 {angstrom} resolution. The active site of the TcPAM contains the signature 4-methylidene-1H-imidazol-5(4H)-one prosthesis, observed in all catalysts of the class I lyase-like family. This catalyst isomerizes (S)-{alpha}-phenylalanine to the (R)-{beta}-isomer by exchange of the NH{sub 2}/H pair. The stereochemistry of the TcPAM reaction product is opposite of the (S)-{beta}-tyrosine made by the mechanistically related tyrosine aminomutase (SgTAM) from Streptomyces globisporus. Since TcPAM and SgTAM share similar tertiary- and quaternary-structures and have several highly conserved aliphatic residues positioned analogously in their active sites for substrate recognition, the divergent product stereochemistries of these catalysts likely cannot be explained by differences in active site architecture. The active site of the TcPAM structure also is in complex with (E)-cinnamate; the latter functions as both a substrate and an intermediate. To account for the distinct (3R)-{beta}-amino acid stereochemistry catalyzed by TcPAM, the cinnamate skeleton must rotate the C{sub 1}-C{sub {alpha}} and C{sub ipso}-C{sub {beta}} bonds 180{sup o} in the active site prior to exchange and rebinding of the NH{sub 2}/H pair to the cinnamate, an event that is not required for the corresponding acrylate intermediate in the SgTAM reaction. Moreover, the aromatic ring of the intermediate makes only one direct hydrophobic interaction with Leu-104. A L104A mutant of TcPAM demonstrated an 1.5-fold increase in k{sub cat} and a decrease in K{sub M} values for sterically demanding 3'-methyl-{alpha}-phenylalanine and styryl-{alpha}-alanine substrates, compared to the kinetic parameters for TcPAM. These parameters did not change significantly for the mutant with 4'-methyl-{alpha}-phenylalanine compared to those for TcPAM.

  16. Prevention of stent thrombosis: challenges and solutions

    Science.gov (United States)

    Reejhsinghani, Risheen; Lotfi, Amir S

    2015-01-01

    Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research. PMID:25657588

  17. 21 CFR 876.4620 - Ureteral stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ureteral stent. 876.4620 Section 876.4620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4620 Ureteral stent. (a) Identification. A ureteral stent...

  18. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  19. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  20. Functional Self-Expandable Metal Stents in Biliary Obstruction

    Science.gov (United States)

    Kwon, Chang-Il; Ko, Kwang Hyun; Hahm, Ki Baik

    2013-01-01

    Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories. PMID:24143314

  1. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  2. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

    Science.gov (United States)

    Kim, Ji Won; Jeong, Ji Bong; Lee, Kook Lae; Kim, Byeong Gwan; Ahn, Dong Won; Lee, Jae Kyung; Kim, Su Hwan

    2015-02-07

    To compare the clinical outcomes of uncovered and covered self-expandable metal stent placements in patients with malignant duodenal obstruction. A total of 67 patients were retrospectively enrolled from January 2003 to June 2013. All patients had symptomatic obstruction characterized by nausea, vomiting, reduced oral intake, and weight loss. The exclusion criteria included asymptomatic duodenal obstruction, perforation or peritonitis, concomitant small bowel obstruction, or duodenal obstruction caused by benign strictures. The technical and clinical success rate, complication rate, and stent patency were compared according to the placement of uncovered (n = 38) or covered (n = 29) stents. The technical and clinical success rates did not differ between the uncovered and covered stent groups (100% vs 96.6% and 89.5% vs 82.8%). There were no differences in the overall complication rates between the uncovered and covered stent groups (31.6% vs 41.4%). However, stent migration occurred more frequently with covered than uncovered stents [20.7% (6/29) vs 0% (0/38), P stent patency was longer in uncovered than in covered stents [251 d (95%CI: 149.8 d-352.2 d) vs 139 d (95%CI: 45.5 d-232.5 d), P stent (70 d) and covered stent groups (60 d). Uncovered stents may be preferable in malignant duodenal obstruction because of their greater resistance to stent migration and longer stent patency than covered stents.

  3. Management of JJ stent-related symptoms.

    Science.gov (United States)

    Papatsoris, Athanasios; Dellis, Athanasios; Daglas, George; Sanguedolce, Francesco

    2014-01-01

    Ureteric JJ stents are inserted in numerous pa- tients as a routine procedure. Nevertheless, the ideal JJ stent that does not cause any lower urinary tract symptoms has not been developed yet. Even special validated ques- tionnaires have been used for the assessment of JJ stent-related symtoms. For the management of such symtoms usually alpha-blockers are admin- istered. Also, studies have examined the efficacy and safety of anticholinergics and calcium channel blo- ckers. In this article we review the literature upon the management of JJ stent-related symptoms.

  4. iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Malvankar-Mehta, Monali S; Chen, Yufeng Nancy; Iordanous, Yiannis; Wang, Wan Wendy; Costella, John; Hutnik, Cindy M L

    2015-01-01

    Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of

  5. Quantification of in-stent restenosis parameters in rabbits by micro-CT

    International Nuclear Information System (INIS)

    Langheinrich, A.C.; Zoerb, C.; Jajima, J.; Lommel, D.; Rau, W.S.; Walker, G.; Mueller, K.M.; Bohle, R.M.

    2005-01-01

    Purpose: The well-defined model of angioplasty and stent implantation in the rabbit aorta is useful in experimental studies of restenosis. This study was performed to evaluate the feasibility of Micro-CT for quantification of in-stent restenosis in a rabbit aortic in-stent restenosis model. Material and Methods: To induce in-stent restenosis seven female New Zealand rabbits underwent balloon dilation and denudation prior to stenting the abdominal aorta. After six weeks on atherogenic diet, animals were killed and the aorta was perfused with contrast agent. Micro-CT morphometric analysis of balloon and stent injured arteries obtained by 700 transverse sections (voxel size 10 μm) was compared to conventional histological analysis. Results: Intimal hyperplasia was present in stented and balloon injured arteries with a moderate intimal area assessed by Micro-CT and conventional histology (3.91±0.5 mm 2 vs. 4.18±0.42; r=0.9). High significant correlations between Micro-CT image analysis and conventional histomorphometry were obtained for lesion size, size of media, size of lumen and stent area (r=0.84 to 0.96). Conclusion: Micro-CT is feasible for quantitative information about restenosis following balloon angioplasty and stent implantation and has the potential to become a standard technique in many laboratories which will augment serial histology as the reference method for ex-vivo studies of restenosis. (orig.)

  6. 21 CFR 884.3900 - Vaginal stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  7. Temporary self-expanding cardia stents for the treatment of achalasia: an experimental study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Cheng Yingsheng; Li Minghua; Zhao Jungong; Li Feng; Chen Niwei

    2011-01-01

    Objective: To assess the performance, efficiency and optimal removal time of a newly designed temporary retrievable cardia covered stent (TRC-CS) for the treatment of achalasia in a dog model. Methods: Eighty-four achalasia-like dog models were randomly divided into seven groups of 12, a control group (CG; no stent insertion), a standard stent control group (NSCG, standard esophageal stent) and five treatment groups (TG, TRC-CS). Stents were retrieved at 4 days after insertion in the NSCG and at 4 days (4 d-TG), 2 weeks (2 w-TG), 1 month (1 m-TG), 3 months (3 m-TG), and 6 months (6 m-TG) in the TGs. lower esophageal sphincter pressure (LESP) and a timed barium esophagram were assessed before stent insertion, after stent retrieval, and at 1-week, 1-, 3- and 6-month follow-up. Three dogs in NSCG and 4 d-TG were sacrificed for histological examination at each follow-up to investigate the inflammatory reaction after stent insertion. Results: Stent insertion/removal and the follow-up procedures were well tolerated. At 6-month follow-up, the 2 w-TG and 1 m-TG demonstrated an acceptable stent migration (n=2 in both TGs versus n=4 in NSCG, n=4 in 3 m-TG, and =6 in 6 m-TG), improved LESP compared to after BAC injection (P<0.05), and improved timed barium height (p=0.0144 and 0.0409). Mouse-proliferating cell nuclear antigen (PCNA) and α-smooth muscle actin staining revealed no inflammatory reaction difference between the NSCG and 4d-TG at each follow-up. Conclusion: The TRC-CS was effective in the treatment of achalasia in a dog model. LESP measurements, timed barium esophagram studies suggest an optimal stent retrieval time of between 2 w∼1 m. (authors)

  8. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  9. Iliocaval Confluence Stenting for Chronic Venous Obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Rick de, E-mail: r.de.graaf@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands); Wolf, Mark de, E-mail: markthewolf@gmail.com [Maastricht University Medical Centre (MUMC), Department of Surgery (Netherlands); Sailer, Anna M., E-mail: anni.sailer@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands); Laanen, Jorinde van, E-mail: jorinde.van.laanen@mumc.nl; Wittens, Cees, E-mail: c.wittens@me.com [Maastricht University Medical Centre (MUMC), Department of Surgery (Netherlands); Jalaie, Houman, E-mail: hjalaie@ukaachen.de [University Hospital Aachen, Department of Surgery (Germany)

    2015-10-15

    PurposeDifferent techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.Materials and MethodsBetween 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) or high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents.ResultsRecanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days.ConclusionStenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.

  10. Provisional versus elective two-stent strategy for unprotected true left main bifurcation lesions: Insights from a FAILS-2 sub-study.

    Science.gov (United States)

    Kawamoto, Hiroyoshi; Chieffo, Alaide; D'Ascenzo, Fabrizio; Jabbour, Richard J; Naganuma, Toru; Cerrato, Enrico; Ugo, Fabrizio; Pavani, Marco; Varbella, Ferdinando; Boccuzzi, Giacomo; Pennone, Mauro; Garbo, Roberto; Conrotto, Federico; Biondi-Zoccai, Giuseppe; D'Amico, Maurizio; Moretti, Claudio; Escaned, Javier; Gaita, Fiorenzo; Nakamura, Sunao; Colombo, Antonio

    2018-01-01

    This study sought to investigate the optimal percutaneous coronary intervention (PCI) strategy for true unprotected left main coronary artery (ULMCA) bifurcations. The FAILS-2 was a retrospective multi-center study including patients with ULMCA disease treated with second-generation drug-eluting stents. Of these, we compared clinical outcomes of a provisional strategy (PS; n=216) versus an elective two-stent strategy (E2S; n=161) for true ULMCA bifurcations. The primary endpoint was the incidence of major adverse cardiac events (MACEs) at 3-years. We further performed propensity-score adjustment for clinical outcomes. There were no significant differences between the groups in terms of patient and lesion characteristics. 9.7% of patients in the PS group crossed over to a provisional two-stent strategy. MACEs were not significantly different between groups (MACE at 3-year; PS 28.1% vs. E2S 28.9%, adjusted p=0.99). The rates of target lesion revascularization (TLR) on the circumflex artery (LCX) were numerically high in the E2S group (LCX-TLR at 3-years; PS 11.8% vs. E2S 16.6%, adjusted p=0.51). E2S was associated with a comparable MACE rate to PS for true ULMCA bifurcations. The rates of LCX-TLR tended to be higher in the E2S group although there was no statistical significance. This study sought to compare the clinical outcomes of a provisional strategy (PS) with an elective two-stent strategy (E2S) for the treatment of true unprotected left main coronary artery bifurcations. 377 Patients (PS 216 vs. E2S 161 patients) were evaluated, and 9.7% in the PS group crossed over to a two-stent strategy. E2S was associated with a similar major adverse cardiac event rate at 3-years when compared to the PS strategy (PS 28.1% vs. E2S 28.9%, p=0.99). However, the left circumflex artery TLR rate at 3-year tended to be higher in the E2S group (PS 11.8% vs. E2S 16.6%, p=0.51). Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Antral localization worsens the efficacy of enteral stents in malignant digestive tumors.

    Science.gov (United States)

    Dolz, Carlos; Vilella, Àngels; González Carro, Pedro; González Huix, Ferran; Espinós, Juan Carlos; Santolaria, Santos; Pérez Roldán, Francisco; Figa, Montserrat; Loras, Carmen; Andreu, Hernán

    2011-02-01

    Malignant gastric outlet obstruction can be treated by means of enteral stenting or surgical gastrojejunalanatomosis. We evaluated in a prospective and multicentre study the efficacy of the enteral stent on food intake, the quality of life impact, and the relationship between efficacy and determined clinical and technical parameters. Seventy one patients affected by symptoms arising from gastroduodenal obstruction due to malignant tumors, with criteria of irresecability, metastatic disease or very high surgical risk, were treated by means of self expanding metal stents. We used the GOOSS index to evaluate efficacy, and the Euro Qol-5D index to evaluate quality of life. Before stenting patients with GOOSS 0 and 1 were 68 (98.5%). After stenting patients with GOOSS 2 and 3 (semisolid and solid food) were 58 (84,1%) (P<.0001). The Euro Qol-5D index measured before and a month after stenting were 10.17 and 10.04 respectively (P=.6). The median survival was 91 days (9-552). The enteral stents for localised tumors in the duodenum and the gastrojejunalanastomosis were effective in 26 patients (70.2%) and 13 patients respectively (86.6%), while the enteral stents of tumors in the antrum were effective in only 5 patients (29.4%). The palliative treatment of malignant gastric outlet obstruction with a uncovered metal stent produces a significant improvement of oral food intake and maintains the overall quality of life index. The antral localization is associated with a lower efficacy of the procedure. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  12. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  13. Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia

    International Nuclear Information System (INIS)

    Profili, Stefano; Manca, Antonio; Feo, Claudio F.; Padua, Guglielmo; Ortu, Riccardo; Canalis, Giulio C.; Meloni, Giovanni B.

    2007-01-01

    Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technical success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated

  14. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  15. On-site customization of silicone stents: towards optimal palliation of complex airway conditions.

    Science.gov (United States)

    Breen, David P; Dutau, Hervé

    2009-01-01

    Stents may be indicated as treatment of benign and malignant conditions of the central airways. Occasionally, aberrant and/or distorted airways secondary to therapy or surgery may preclude the use of commercially manufactured stents. The customization of stents is well described for nonpulmonary diseases, but to date there are only limited data in the literature on prosthesis customization for airway disease. To review all the different techniques and indications of on-site silicone stent customizations and their related complications. A retrospective study was undertaken to identify all patients who underwent treatment with a silicone stent which was customized on site by the physician. The study included subjects treated during an 8-year period. Forty-nine on-site customizations were performed in 43 patients (34 males, mean age 63 +/- 5.2 years). Stent customization was performed in 5.4% of the cases. Stent customization was performed for malignant and benign disease in 35 (81.3%) and 8 (18.7%) cases, respectively. In all cases, the stent deployed successfully and performed well while in situ. Stent manipulation did not increase complications. Customization of airway stents by the physician can lead to successful stenting of difficult airway lesions with a good short-term safety profile. Standard commercially available stents may have resulted in suboptimal management of complex airway pathologies. A prospective study is warranted to further investigate the safety profile and complications associated with stent customization. Copyright 2009 S. Karger AG, Basel.

  16. Elective implantation of covered stents for coarctation and recoarctation in adolescents and adults.

    Science.gov (United States)

    Alcibar, Juan; Blanco, Roberto; Fernandez, Luis; Arriola, Josune; Garcia, Koldobika; Peña, Natividad; Inguanzo, Ramón; Voces, Roberto; Castellanos, Enrique; Montes, Pedro M

    2013-06-01

    Stent implantation is an effective therapy for aortic coarctation and recoarctation. However, in adolescents and adults, aortic wall rupture and dissection can occur, as well as aneurysms during follow-up. In order to reduce these complications, we electively implant covered stents. Since 2005, we have performed the procedure using femoral access in 17 patients (2 adolescents and 15 adults), 16 electively and 1 as a rescue procedure. We used the Mullins technique in all cases, implanting a NuMED(®) covered stent. Good stent apposition was achieved in all 17 procedures; 8 patients required a distal flare. Gradient was reduced from 40 (16) mmHg to 2 (2) mmHg (P<.001) and lumen diameter increased from 4 (2) mm to 19 (3) mm (P<.001). Two exceptional cases are discussed: one patient with aortic wall rupture who underwent a rescue procedure using a stent within a covered stent and another patient with total obstruction and intercostal aneurysm in whom the outcome was fatal at 48 h postprocedure (autopsy is shown). Four-year clinical follow-up included Doppler echocardiography; an additional imaging technique was required in 13 patients. All patients recovered well and there were no complications. Covered stents are effective in treating coarctation and recoarctation in adolescents and adults, are the treatment of choice in patients with complex anatomy, and must be available in the operating room as a rescue device when implanting a conventional stent. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  17. Stenting plus coiling: dangerous or helpful?; Stenting plus Coiling bei akut rupturierten intrakraniellen Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, I.; Gizewski, E.; Doerfler, A.; Stolke, D.; Forsting, M. [Essen Univ. (Germany). Inst. fuer Radiologie und Neuroradiologie

    2005-09-01

    Purpose: the purpose of this study was to evaluate the procedural risk of treating acute ruptured aneurysms with a stentcoil combination. Material and methods: between August 2001 and January 2004 we treated nine acute subarachnoid hemorrhage (SAH) patients with a combination of stents and platinum coils. Results: six aneurysms were 100% eliminated; the residual three aneurysms had a 95% to 99% occlusion. A transient thrombosis in the stent in one patient could be recanalized by intravenous application of ReoPro {sup registered}. In another patient an occlusive vasospasm at the distal end of the stent was successfully treated with intraarterial Nimotop {sup registered}. Neurological complications occurred in none of the patients. Conclusion: in broad-based aneurysms which cannot be clipped or in which any neurosurgical treatment presents an unacceptably high risk (posterior circulation and paraophthalmic aneurysms), treatment using a combination of stent and platinum coils might be an option even in the acute phase of an SAH. Platelet aggregation can be treated with Aspirin registered and Plavix {sup registered} after placement of the first coil, vasospasms with intraarterial Nimotop {sup registered}, and acute stent thrombosis with GP IIa/IIIb-antagonists. (orig.)

  18. TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin; Liu, Ling-xiao [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China); Wu, Lin-lin [Tengzhou Central People’s Hospital, Department of Oncology (China); Wang, Jian-hua; Yan, Zhi-ping, E-mail: 798373254@qq.com; Luo, Jian-jun, E-mail: 12211210022@fudan.edu.cn [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2016-09-15

    PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission rate and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.

  19. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  20. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    Directory of Open Access Journals (Sweden)

    Chang-Il Kwon

    2016-03-01

    Full Text Available Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs] have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations.

  1. ILIAC-ARTERY URETERAL-FISTULA ASSOCIATED WITH AN INDWELLING URETERAL STENT

    NARCIS (Netherlands)

    ZWEERS, HMM; VANDRIEL, MF; MENSINK, HJA

    1991-01-01

    We report on a patient with an ureteroiliac artery fistula, which developed after double J stenting. The stent was introduced because of unilateral hydronephrosis 2 months after a Wertheim-Meigs operation preceded by cesium application. The presenting symptom of gross hematuria was initially

  2. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.

    Science.gov (United States)

    Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang

    2017-08-01

    To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. An ovine in vivo framework for tracheobronchial stent analysis.

    Science.gov (United States)

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Shea, Mary B; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2017-10-01

    Tracheobronchial stents are most commonly used to restore patency to airways stenosed by tumour growth. Currently all tracheobronchial stents are associated with complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. The present work develops a computational framework to evaluate tracheobronchial stent designs in vivo. Pressurised computed tomography is used to create a biomechanical lung model which takes into account the in vivo stress state, global lung deformation and local loading from pressure variation. Stent interaction with the airway is then evaluated for a number of loading conditions including normal breathing, coughing and ventilation. Results of the analysis indicate that three of the major complications associated with tracheobronchial stents can potentially be analysed with this framework, which can be readily applied to the human case. Airway deformation caused by lung motion is shown to have a significant effect on stent mechanical performance, including implications for stent migration, granulation formation and stent fracture.

  4. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  5. Stent Recanalization of Chronic Portal Vein Occlusion in a Child

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Solvig, Jan; Schroder, Henrik

    2000-01-01

    An 8-year-old boy with a 21/2 year history of portal hypertension and repeated bleedings from esophageal varices, was referred for treatment. The 3.5-cm-long occlusion of the portal vein was passed and the channel created was stabilized with a balloon-expandable stent; a portosystemic stent-shunt was also created. The portosystemic shunt closed spontaneously within 1 month, while the recanalized segment of the portal vein remained open. The pressure gradient between the intrahepatic and extrahepatic portal vein branches dropped from 17 mmHg to 0 mmHg. The pressure in the portal vein dropped from 30 mmHg to 17 mmHg and the bleedings stopped. The next dilation of the stent was performed 12 months later due to an increased pressure gradient; the gastroesophageal varices disappeared completely. Further dilation of the stent was planned after 2, 4, and 6 years

  6. Palliation of Malignant Biliary and Duodenal Obstruction with Combined Metallic Stenting

    International Nuclear Information System (INIS)

    Akinci, Devrim; Akhan, Okan; Ozkan, Fuat; Ciftci, Turkmen; Ozkan, Orhan S.; Karcaaltincaba, Musturay; Ozmen, Mustafa N.

    2007-01-01

    Purpose. The purpose of this study is to evaluate the efficacy of palliation of malignant biliary and duodenal obstruction with combined metallic stenting under fluoroscopy guidance. Materials and Methods. A retrospective analysis of 9 patients (6 men and 3 women) who underwent biliary and duodenal stenting was performed. The mean age of patients was 61 years (range: 42-80 years). The causes of obstruction were pancreatic carcinoma in 7 patients, cholangiocellular carcinoma in one, and duodenal carcinoma in the other. Biliary and duodenal stents were placed simultaneously in 4 patients. In other 5 patients dudodenal stents were placed after biliary stenting when the duodenal obstruction symptoms have developed. In two patients duodenal stents were advanced via transgastric approach. Results. Technical success rate was 100 %. After percutaneous biliary drainage and stenting bilirubin levels decreased to normal levels in 6 patients and in remaining 3 patients mean reduction of 71% in bilirubin levels was achieved. Tumoral ingrowth occurred in one patient and percutaneous biliary restenting was performed 90 days after the initial procedure. Of the 9 patients, 6 patients were able to tolerate solid diet, whereas 2 patients could tolerate liquid diet and one patient did not show any improvement. Mean survival periods were 111 and 73 days after biliary and duodenal stenting, respectively. Conclusion. Combined biliary and duodenal stent placement which can be performed under fluoroscopic guidance without assistance of endoscopy is feasible and an effective method of palliation of malignant biliary and duodenal obstructions. If transoral and endoscopic approaches fail, percutaneous gastrostomy route allows duodenal stenting

  7. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  8. Use of drug-eluting stents in Victorian public hospitals.

    Science.gov (United States)

    Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J

    2006-10-02

    We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.

  9. Delayed colonic perforation following stent placement for colorectal obstruction: a description of two cases with stent palliation.

    Directory of Open Access Journals (Sweden)

    Jalal Vahedian Ardakani

    2013-10-01

    Full Text Available Bowel stent insertion has a variety of complications one major of which is colonic perforation. The purpose of this article is to reveal two cases with delayed colonic perforation after stent placement to relieve bowel obstruction caused by rectal cancer. The first patient was a 55 year-old man who was a candidate for stent placement to avoid palliative surgery and relieve his bowel obstruction. Although the procedure resulted in complete relief of patient symptoms, but he returned with signs of peritonitis 10 days after the stent placement. A perforation was found at rectosigmoid junction on laparotomy. The second patient was a 60 year-old man who underwent a successful stent placement and returned 3 months later with a complaint of abdominal pain that showed up to be due to a rectal perforation on investigations. In conclusion, bowel perforation following stent placement can be a major complication, so close follow-up is necessary to detect it as soon as possible and prevent it from becoming an irreparable complication.

  10. Characterization of nanostructured ureteral stent with gradient degradation in a porcine model

    Directory of Open Access Journals (Sweden)

    Wang XQ

    2015-04-01

    Full Text Available Xiaoqing Wang,1 Hongli Shan,2 Jixue Wang,1 Yuchuan Hou,1 Jianxun Ding,3 Qihui Chen,1 Jingjing Guan,1 Chunxi Wang,1 Xuesi Chen31Department of Urology, the First Hospital of Jilin University, 2Department of Clinical Laboratory, the First Hospital of Jilin University, 3Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, People’s Republic of ChinaAbstract: A tubular poly(ε-caprolactone (PCL/poly(lactide-co-glycolide (PLGA ureteral stent composed of nanofibers with micropores was fabricated by double-needle electrospinning. The stent was ureteroscopically inserted into six Changbai pigs, and the commercial polyurethane Shagong® stent was inserted into four pigs as control. Intravenous pyelography revealed that the PCL/PLGA stent gradually degraded from the distal end to proximal terminal, and all stents were completely degraded at 10 weeks post-insertion. No significant difference was observed in hydronephrosis severity between the two groups. The levels of serum creatinine and urine pH remained similar throughout the study in the two groups, but the number of white blood cells in the urine was significantly higher in the Shagong® stent group. On Day 70, histological evaluation indicated equivalent histological severity scores in the middle and distal ureter sections and bladder in the two groups. However, the PCL/PLGA stent-implanted pigs had significantly lower mean severity scores in the kidney and proximal ureter sites. These data revealed that the PCL/PLGA stent degraded in a controlled manner, did not induce obstruction, and had a lower urothelial impact in comparison to the Shagong® stent, indicating that the stent exhibited great potential for clinical application.Keywords: nanocomposites, polyesters, poly(ε-caprolactone, poly(lactide-co-glycolide, hydronephrosis severity

  11. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  12. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F. [Dept. of Radiology, South Manchester University Hospitals NHS Trust, Withington Hospital (United Kingdom)

    1999-07-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  13. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    International Nuclear Information System (INIS)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F.

    1999-01-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  14. Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries

    Institute of Scientific and Technical Information of China (English)

    WU Chao; QIU Hong; HU Xiao-ying; RUAN Ying-mao; TIAN Yi; CHU Yan; XU Xin-lin

    2013-01-01

    Background To overcome the drawbacks of permanent stents,biodegradable stents have been studied in recent years.The bioabsorbable polymer vascular scaffold (BVS) was the first bioabsorbable stent to undergo clinical trials,demonstrating safety and feasibility in the ABSORB studies.Iron can potentially serve as the biomaterial for biodegradable stents.This study aimed to assess the short-term safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries.Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine,respectively.Two stents of the same metal base were implanted into one animal.At 28 days the animals were sacrificed after coronary angiography,and histopathological examinations were performed.Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs.(0.45±0.18)mm,P=0.878),neointimal area ((2.55±0.91) mm2 vs.(3.04±1.15) mm2,P=0.360) and percentage of area stenosis ((44.50±11.40)% vs.(46.00±17.95)%,P=0.845) were not significantly different between the iron stents and VISION stents.There was no inflammation,thrombosis or necrosis in either group.The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs.0.88±0.99,P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups.The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs.(65.00±22.04)%,P=0.057),but the difference was not statistically significant.Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge,consistent with iron degradation.No abnormal histopathological changes were detected in coronary arteries or major organs.Conclusions The biodegradable iron stent has

  15. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  16. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  17. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  18. Stenting of major airway constriction

    International Nuclear Information System (INIS)

    Wu Xiaomei

    2002-01-01

    Objective: To investigate the correlated issues in the stenting treatment of major airway constriction. Methods: Nineteen cases of major airway stenting procedure were studied retrospectively. The clinical choice of stents of different advantages or deficiencies were discussed. The importance of intravenous anesthesia supporting, life-parameters monitoring during the procedures and the prevention of complications were analysed. Results: Under intravenous and local anesthesia, 19 Wallstents had been successively placed and relieved 19 cases of major airway constrictions due to malignant or benign diseases (15 of tumors, 3 of tuberculosis, 1 of tracheomalacia). Intravenous anesthesia and life-parameters monitoring had made the procedures more safe and precise. Conclusions: Major airway stenting is an reliable method for relieving tracheobronchial stenosis; and intravenous anesthesia supporting and life-parameters monitoring guarantee the satisfactions of procedures

  19. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  20. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.