WorldWideScience

Sample records for tape obturator inside-out

  1. Anatomical variability in the trajectory of the inside-out transobturator vaginal tape technique (TVT-O)

    NARCIS (Netherlands)

    Hinoul, Piet; Vanormelingen, Linda; Roovers, Jan-Paul; de Jonge, Eric; Smajda, Stéfan

    2007-01-01

    An experimental surgical study on human cadavers was undertaken to assess variability in the trajectory followed by the needle during application of the inside-out transobturator tape suspension (TVT-O) technique. The TVT-O surgical procedures were performed on six fresh female cadavers according to

  2. Effectiveness of Retropubic Tension-Free Vaginal Tape and Transobturator Inside-Out Tape Procedures in Women With Overactive Bladder and Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Ji-Yeon Han

    2013-09-01

    Full Text Available Purpose We compared the effectiveness of the retropubic tension-free vaginal tape (TVT and the transobturator inside-out tape (TVT-O in treating symptoms of overactive bladder (OAB in women with stress urinary incontinence (SUI. Methods Women with urodynamic SUI and OAB (mean urgency episodes ≥1 and frequency ≥8/24 hours on a 3-day voiding diary were assigned to the TVT or TVT-O group. Preoperative measures were based on a urodynamic study, 3-day voiding diary, the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTSSF, and the urgency perception scale (UPS. At 12 postoperative months, the 3-day voiding diary, symptoms questionnaire, patient satisfaction, and standing stress test were assessed. The primary endpoint was change in the number of urgency episodes/24 hours from baseline to 12 months. Results In this group of 132 women, 42 received TVT and 90 received TVT-O. The mean urgency episodes/24 hours decreased from 6.3±5.5 to 1.6±3.2 in the TVT group and from 5.1±4.4 to 1.8±3.0 in the TVT-O group. The mean percent change was significantly greater after TVT than after TVT-O (73% vs. 60%, P=0.049. All subscales of BFLUTSSF and UPS were significantly improved using either method, with significantly greater improvement seen in the quality of life (QoL domain after TVT (P=0.002. There were no significant differences in the cure and satisfaction rates between the two groups. Conclusions Intervention with the TVT or the TVT-O significantly improved symptoms of OAB in women with SUI and OAB. Urgency and QoL significantly improved after TVT compared with that after TVT-O.

  3. Effectiveness of Retropubic Tension-Free Vaginal Tape and Transobturator Inside-Out Tape Procedures in Women With Overactive Bladder and Stress Urinary Incontinence

    Science.gov (United States)

    Han, Ji-Yeon; Choo, Myung-Soo; Lee, Young-Suk; Seo, Ju Tae; Kim, Jang Hwan; Kim, Young Ho

    2013-01-01

    Purpose We compared the effectiveness of the retropubic tension-free vaginal tape (TVT) and the transobturator inside-out tape (TVT-O) in treating symptoms of overactive bladder (OAB) in women with stress urinary incontinence (SUI). Methods Women with urodynamic SUI and OAB (mean urgency episodes ≥1 and frequency ≥8/24 hours on a 3-day voiding diary) were assigned to the TVT or TVT-O group. Preoperative measures were based on a urodynamic study, 3-day voiding diary, the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTSSF), and the urgency perception scale (UPS). At 12 postoperative months, the 3-day voiding diary, symptoms questionnaire, patient satisfaction, and standing stress test were assessed. The primary endpoint was change in the number of urgency episodes/24 hours from baseline to 12 months. Results In this group of 132 women, 42 received TVT and 90 received TVT-O. The mean urgency episodes/24 hours decreased from 6.3±5.5 to 1.6±3.2 in the TVT group and from 5.1±4.4 to 1.8±3.0 in the TVT-O group. The mean percent change was significantly greater after TVT than after TVT-O (73% vs. 60%, P=0.049). All subscales of BFLUTSSF and UPS were significantly improved using either method, with significantly greater improvement seen in the quality of life (QoL) domain after TVT (P=0.002). There were no significant differences in the cure and satisfaction rates between the two groups. Conclusions Intervention with the TVT or the TVT-O significantly improved symptoms of OAB in women with SUI and OAB. Urgency and QoL significantly improved after TVT compared with that after TVT-O. PMID:24143294

  4. Trans-obturator Tape in surgical treatment of urinary incontinence

    Directory of Open Access Journals (Sweden)

    Ashrafi M

    2008-06-01

    Full Text Available Background: The aim of this study was to assess the efficacy and safety of a new minimally-invasive surgical procedure using trans-obturator Tape (TOT to treat female stress urinary incontinence.Methods: This clinical trial study was performed from 2003 to 2004 in the Gynecology Department of Imam Hospital, Vali-e-Asr, Tehran, Iran. A total of 35 women with stress urinary incontinence underwent the TOT procedure. All patients underwent pre-operative clinical examination, cough-stress test (full bladder, uroflowmetry and post-voiding residual volume assessment. Results: The mean age of patients was 50 years, ranging from 26 to 74 years, with an average urinary stress incontinence duration of six years. The mean time of follow-up was 14 months (at 1, 6, 12 and 24 months and the average duration of surgery was about 20 minutes. The perioperative complication rate was 9% with no vascular, nerve or bowel injuries. The rate of hemorrhagic side effects (spontaneously-absorbed hematoma and blood loss not requiring blood transfusion was 2.9%. Post-operative urinary retention and vaginal erosion occurred in one case each; the former was treated by intermittent self-catheterization. In total, 91.4% of patients were completely cured and 8.6% were improved without failure of treatment. Conclusions: The present study confirms the results obtained by Delorme and coworkers, and allows us to consider TOT as a safe, minimally invasive and efficient short-term surgical technique for the treatment of female stress urinary incontinence, alone or in combination with prolapse repair. Following this study, a randomized control trial is recommended to compare TOT with the gold standard surgery for women with urinary incontinence.

  5. Obturator Neuralgia: A Rare Complication of Tension-free Vaginal Tape Sling-Complete Resolution After Laparoscopic Tension-free Vaginal Tape Removal.

    Science.gov (United States)

    Miklos, John R; Moore, Robert D; Chinthakanan, Orawee

    2015-01-01

    To show a technique of retropubic tension-free vaginal tape (TVT) removal using both a transvaginal and laparoscopic approach in the treatment of a rare condition, obturator neuralgia. A step-by-step explanation of the patient's condition, diagnosis, surgical technique, and postoperative results using video, pictures, and medical illustrations (education video). TVT retropubic slings have become the gold standard for the treatment of stress urine incontinence over the last decade. Despite high cure rates, the TVT is not without potential complications. Typical complications include urine retention, incomplete bladder emptying, frequency, urgency, urethral erosion, vaginal extrusion, vaginal pain, and dyspareunia. The most common complication for sling removal/revision is chronic pain. The TVT obturator neuralgia is a rare and specific type of chronic pain that is normally associated with transobturator tape slings. The purpose of this video is to present an extremely rare complication of TVT retropubic slings, present symptoms and signs of obturator nerve compression, show the normal and the actual position of this patient's TVT sling, describe the laparoscopic removal of the TVT sling, and present the postoperative course and resolution of the patient's pain. The patient signed a release for her video to be used for educational and teaching purposes. A combined transvaginal and laparoscopic approach in a patient with lower abdominal, levator, and obturator-type pain after a TVT retropubic procedure. In patients suffering from obturator neuralgia after a retropubic sling, surgeons should include the sling as a potential causative factor in the differential diagnosis. Surgeons should consider removing the sling based on the patient's symptoms. If the patient suffers from only vaginal pain and dyspareunia, then the surgeon should consider only the removal of the vaginal portion of the sling. In patients with obturator neuralgia, retropubic, and/or lower abdominal

  6. Modified prepubic TVT-obturator tape procedure versus the conventional method: a preliminary study.

    Science.gov (United States)

    Long, Cheng-Yu; Wu, Ming-Ping; Wang, Chiu-Lin; Lin, Kun-Ling; Liu, Cheng-Min; Wu, Shu-Hui; Juan, Yung-Shun

    2013-12-01

    To compare the efficacy and safety of the modified prepubic tension-free vaginal tape-obturator (PTVT-O) system procedure with the original TVT-O methods. One hundred and ninety women with urodynamic stress incontinence (USI) were included in this study (93 cases in the TVT-O group and 97 in the PTVT-O group). Clinical assessments before and one year after surgery included urinalyses, 1-h pad tests, urodynamic studies, and a personal interview with the overactive bladder symptom score (OABSS) questionnaire. There were no differences between the two groups in mean age, parity, menopausal status, mean operative time and subjective cure rates (P>0.05), but the efficacy of surgery (cure and improvement) in the PTVT-O group was significantly higher than that in the TVT-O group (P=0.038). Complication rates and visual analog scale (VAS) scores were found to be similar (P>0.05). OABSS decreased significantly after surgery in both groups (P0.05). Our modified procedure is a safe and effective treatment for female USI. It has an advantage over the original TVT-O with better surgical efficacy and comparable postoperative pain, although the follow-up times in this study are different. Copyright © 2013. Published by Elsevier Ireland Ltd.

  7. Inside-out planet formation

    International Nuclear Information System (INIS)

    Chatterjee, Sourav; Tan, Jonathan C.

    2014-01-01

    The compact multi-transiting planet systems discovered by Kepler challenge planet formation theories. Formation in situ from disks with radial mass surface density, Σ, profiles similar to the minimum mass solar nebula but boosted in normalization by factors ≳ 10 has been suggested. We propose that a more natural way to create these planets in the inner disk is formation sequentially from the inside-out via creation of successive gravitationally unstable rings fed from a continuous stream of small (∼cm-m size) 'pebbles', drifting inward via gas drag. Pebbles collect at the pressure maximum associated with the transition from a magnetorotational instability (MRI)-inactive ('dead zone') region to an inner MRI-active zone. A pebble ring builds up until it either becomes gravitationally unstable to form an ∼1 M ⊕ planet directly or induces gradual planet formation via core accretion. The planet may undergo Type I migration into the active region, allowing a new pebble ring and planet to form behind it. Alternatively, if migration is inefficient, the planet may continue to accrete from the disk until it becomes massive enough to isolate itself from the accretion flow. A variety of densities may result depending on the relative importance of residual gas accretion as the planet approaches its isolation mass. The process can repeat with a new pebble ring gathering at the new pressure maximum associated with the retreating dead-zone boundary. Our simple analytical model for this scenario of inside-out planet formation yields planetary masses, relative mass scalings with orbital radius, and minimum orbital separations consistent with those seen by Kepler. It provides an explanation of how massive planets can form with tightly packed and well-aligned system architectures, starting from typical protoplanetary disk properties.

  8. Randomized clinical trial comparing TVT Secur system and trans vaginal obturator tape for the surgical management of stress urinary incontinence.

    Science.gov (United States)

    Maslow, Ken; Gupta, Chander; Klippenstein, Peter; Girouard, Lise

    2014-07-01

    This prospective randomized study aimed to compare the safety and efficacy of the TVT-Secur (TVT-S) with the trans vaginal obturator tape (TVT-O) for the treatment of stress urinary incontinence. We set out to enroll 136 patients in our study. 106 patients with stress urinary incontinence were randomized to either the TVT-S (n = 56) or TVT-O (n = 50) procedure. Patients were evaluated postoperatively at 2 months and 1 year. Our primary outcome was objective cure measured by the cough test. Secondary outcomes of subjective symptoms, questionnaires, pain scores, complications, and urodynamic studies were also included. Statistical analysis was by Chi-squared, Kruskal-Wallis, Wilcoxon, and Fisher's exact tests as appropriate. P values of TVT-O compared with TVT-S at 1 year (86 % and 63 % respectively, p = 0.01). Subjective cure rates were 88 % for TVT-O and 63 % for TVT-S. Quality of life scores through questionnaires improved in both groups and were not statistically different. Initial post-operative groin pain was more prevalent in the TVT-O group; however, this resolved quickly with time. TVT-O was superior to TVT-S in the objective cure of stress urinary incontinence at 1-year follow-up.

  9. Turning nuclear communications inside out

    International Nuclear Information System (INIS)

    Besenyei, Elisabeth; Czibolya, Laszlo

    2002-01-01

    Due to debates on the security of energy supply in the European Union, the international efforts on the implementation of Kyoto protocol and the forthcoming liberalization of the electrical energy market the attention of Hungarian decision-makers was focused on energy related problems. Discussions started on the future role of nuclear power and anti-nuclear environmentalists became more active in their criticism. Changes were needed in the approach and practice of communication on nuclear energy. Previous practice turned to be inefficient in dialogue with different social and influential groups. Public information could not be considered any more as an activity explaining measures to cope with incidents and accidents or giving technical answers to mostly superficial statements on allegedly unsafe features and solutions in nuclear industry. It was time to change the paradigm and to turn the communication into a powerful tool to put forward the arguments, to show the achievements and facts and to explain the efforts in addressing public concerns. The new paradigm turned the previous outside-in approach to a new inside-out type of behavior. Instead of reacting to the attacks coming from outside the new approach means first of all commitment to be open and pro-active in communication and to act in close cooperation with all interested organizations and institutions. The three pillars of the new paradigm, commitment, communication and co-operation are applicable not only for the nuclear industry, but also for the governmental agencies (regulatory bodies, health and emergency authorities etc.) and for the wide range of technical, scientific and civil organizations. Public information should be turned from a burden to a challenge for open, technically valid and honest dialogue. This active communication approach is illustrated by some new initiatives in public information in Hungary. Following the successful Nuclear Academy for Journalists formed new Section of Nuclear

  10. Trans-obturator vaginal tape (TOT) for female stress incontinence: one year follow-up in 120 patients.

    Science.gov (United States)

    Roumeguère, Thierry; Quackels, Th; Bollens, R; de Groote, A; Zlotta, A; Bossche, M Vanden; Schulman, C

    2005-11-01

    The aim of this study was to evaluate the effectiveness of a new minimally invasive surgical procedure, the Trans-obturator Vaginal Tape (TOT) in the treatment of female urodynamic stress incontinence (USI) and to analyse functional results and quality of life after one year of follow up. 120 consecutive women with stress urinary incontinence underwent the procedure since February 2002 under general or loco-regional anesthesia. Minimum follow up was one year (range 12-30 months). Mean age was 58 years (range 31-86). 70% of the patients had pure USI. 5 patients were previously operated for USI. In 10 cases, concomitant repair of pelvic floor defects was mandatory. Collection of the data included operative time, pre- and post-operative complications. Patients were post-operatively assessed at one week, one month and one year. A validated urinary incontinence-specific measure of Quality of Life (QoL) questionnaire (Contilife) was sent and completed 12 months after surgery. The mean operative time was 12 min (range 6-30) with a catheterisation time of 0,9 day (range 0-2). No severe bleeding was observed. There were 13 minor lateral tears of the vagina without any sequelae. Three perforations of the urethra and one of the bladder occurred during the learning phase. In two cases a re-intervention was necessary for tape removal when the injury was not recognised during the procedure. Two transient urinary retention needed a supra pubic catheter and tape release. Eleven women presented transient voiding outflow obstruction. After one month, 93% patients were cured with no pad and a negative cough test with a full bladder. Uroflowmetry did not show any significant changes between pre- and post-operative time in all the population. De novo urgency occurred only in 2.5% and persistent dysuria (Qmax 120 cc) in 4%. 80% of patients were completely dry after one year and 12% were greatly improved. According to the pre-operative maximal urethral closure pressure, continence rate

  11. Uroflowmetric changes, success rate and complications following Tension-free Vaginal Tape Obturator (TVT-O) operation in obese females.

    Science.gov (United States)

    Fouad, Reham; El-Faissal, Yahia M; Hashem, Ahmed T; Gad Allah, Sherine H

    2017-07-01

    The goal of this study was to evaluate the outcome of Tension-free Vaginal Tape Obturator (TVT-O) operation in the treatment of urodynamic stress incontinence (USI) in obese females, with respect to uroflowmetric changes, success rate and postoperative complications. This prospective observational study included 26 patients with USI at the Obstetrics & Gynecology department-Cairo University hospital during the year 2015. The participants had body mass index (BMI)≥30. Patients underwent TVT-O operation. Follow up of the patients was performed by cough test and uroflowmetry after one week, one month, three months and six months. Postoperative complications such as groin pain, sense of incomplete emptying, need to strain to complete micturition and urinary tract infection were recorded. Comparisons between groups were done using Chi square, Phi-Cramer test for categorical variables. The mean age for the subjects was 43.58±9.01years. The mean BMI was 33.4±2.1. The success rate of TVT-O operation was 21 out of 26 patients (≈81%). Normal maximum flow rate was in 88% of patients at week one and was normal in 100% of patients at months three and six (p=0.101 & 0.101). Postoperative groin pain was the main complaint during the first week after operation and decreased significantly from week one to the 1st month postoperative (84.62% & 65.38%, P=0.041). TVT-O operation showed a high success rate in treatment of USI in obese patients without affecting the voiding function of the bladder as proven by the uroflowmetry. The main postoperative complaint was the groin pain which significantly improved after one month. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Windows Server® 2008 Inside Out

    CERN Document Server

    Stanek, William R

    2009-01-01

    Learn how to conquer Windows Server 2008-from the inside out! Designed for system administrators, this definitive resource features hundreds of timesaving solutions, expert insights, troubleshooting tips, and workarounds for administering Windows Server 2008-all in concise, fast-answer format. You will learn how to perform upgrades and migrations, automate deployments, implement security features, manage software updates and patches, administer users and accounts, manage Active Directory® directory services, and more. With INSIDE OUT, you'll discover the best and fastest ways to perform core a

  13. Inside-out electrical capacitance tomography

    DEFF Research Database (Denmark)

    Kjærsgaard-Rasmussen, Jimmy; Meyer, Knud Erik

    2011-01-01

    In this work we demonstrate the construction of an ‘inside-out’ sensor geometry for electrical capacitance tomography (ECT). The inside-out geometry has the electrodes placed around a tube, as usual, but measuring ‘outwards’. The flow between the electrodes and an outer tube is reconstructed...

  14. Effect of tension-free vaginal tape and TVT-obturator on lower urinary tract symptoms other than stress urinary incontinence.

    Science.gov (United States)

    Ballert, Katie N; Kanofsky, Jamie A; Nitti, Victor W

    2008-03-01

    Variable effects on lower urinary tract symptoms (LUTS) other than stress urinary incontinence (SUI) have been reported after tension-free vaginal tape (TVT). We measured the effect of TVT on LUTS using the American Urological Association Symptom Index (AUASI). Patients undergoing TVT completed the AUASI pre- and post-operatively. Total scores (TS), storage scores (SS), and voiding scores (VS) were compared overall and among patients with SUI vs mixed urinary incontinence (MUI) and those who underwent TVT vs TVT-obturator (TVT-O). The mean change in TS and SS was -3.6 and -3.0. Mean reductions in TS and SS were significant in all patient subsets with no change in VS. There was no significant difference in the mean changes in TS between patients with SUI vs MUI or those undergoing TVT vs TVT-O. LUTS are improved after TVT in most patients. In general, voiding symptoms were not adversely affected.

  15. Inside-out neuropharmacology of nicotinic drugs.

    Science.gov (United States)

    Henderson, Brandon J; Lester, Henry A

    2015-09-01

    Upregulation of neuronal nicotinic acetylcholine receptors (AChRs) is a venerable result of chronic exposure to nicotine; but it is one of several consequences of pharmacological chaperoning by nicotine and by some other nicotinic ligands, especially agonists. Nicotinic ligands permeate through cell membranes, bind to immature AChR oligomers, elicit incompletely understood conformational reorganizations, increase the interaction between adjacent AChR subunits, and enhance the maturation process toward stable AChR pentamers. These changes and stabilizations in turn lead to increases in both anterograde and retrograde traffic within the early secretory pathway. In addition to the eventual upregulation of AChRs at the plasma membrane, other effects of pharmacological chaperoning include modifications to endoplasmic reticulum stress and to the unfolded protein response. Because these processes depend on pharmacological chaperoning within intracellular organelles, we group them as "inside-out pharmacology". This term contrasts with the better-known, acute, "outside-in" effects of activating and desensitizing plasma membrane AChRs. We review current knowledge concerning the mechanisms and consequences of inside-out pharmacology. This article is part of the Special Issue entitled 'The Nicotinic Acetylcholine Receptor: From Molecular Biology to Cognition'. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT versus tension-free vaginal tape (TVT five years after a randomized surgical trial

    Directory of Open Access Journals (Sweden)

    Eliasziw Misha

    2011-07-01

    Full Text Available Abstract Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT versus the trans-obturator tape (TOT procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7. Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes

  17. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT) versus tension-free vaginal tape (TVT) five years after a randomized surgical trial

    Science.gov (United States)

    2011-01-01

    Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT) versus the trans-obturator tape (TOT) procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7). Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes more adverse events, or is

  18. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency.

    Science.gov (United States)

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223-12.582, p = 0.022) was a risk factor for failure following surgical treatment. TVT is more effective than TOT in treatment of female SUI with ISD.

  19. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

    Science.gov (United States)

    Masata, Jaromir; Svabik, Kamil; Zvara, Karel; Hubka, Petr; Toman, Ales; Martan, Alois

    2016-10-01

    The aim of this study was to compare the efficacy of the tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of stress urinary incontinence in a randomized two-arm study with a 1-year follow-up. This single-centre randomized trial compared the objective and subjective cure rates of TVT-O and Ajust using objective criteria (cough test) and subjective criteria (International Consultation on Incontinence Questionnaire short form, ICIQ-UI SF). The objective cure rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined as no stress leakage of urine after surgery based on the ICIQ-UI SF. The primary outcome was to establish differences in objective and subjective cure rates between the TVT-O and Ajust groups. We also compared postoperative pain profiles using a visual analogue scale (VAS), improvement in quality of life using the ICIQ- UI SF and the Incontinence Quality of Life questionnaire, and overall satisfaction with the surgical procedure using a VAS and a five-item Likert scale. Inclusion criteria were age over 18 years, signed informed consent, and urodynamic stress urinary incontinence. Following a power calculation, 50 patients were enrolled into each group (Ajust and TVT-O). The mean follow-up after surgery was 445 days (SD 157.6 days) in the TVT-O group and 451.8 days (SD 127.6 days) in the Ajust group (p = 76.6 %). At 1 year, 47 patients were evaluated in the TVT-O group and 49 in the Ajust group. No differences in subjective cure rates or objective cure rates were observed. In the Ajust and TVT-O groups, the rates for no subjective stress leakage were 89.8 % and 91.5 %, respectively (p = 1.0, OR 1.22, 95 % CI 0.24 - 6.58), and the rates for a negative stress test were 89.8 % and 87.2 %, respectively (p = 0.76, OR 0.77, 95 % CI 0.17 - 3.32). In the Ajust group two patients reported de novo pain during sexual

  20. Outcome of Treatment of Anterior Vaginal Wall Prolapse and Stress Urinary Incontinence with Transobturator Tension-Free Vaginal Mesh (Prolift and Concomitant Tension-Free Vaginal Tape-Obturator

    Directory of Open Access Journals (Sweden)

    Sameh Azazy

    2008-12-01

    Full Text Available Objective. It is to assess the feasibility, effectiveness, and safety of transobturator tension-free vaginal mesh (Prolift and concomitant tension-free vaginal tape-obturator (TVT-O system as a treatment of female anterior vaginal wall prolapse associated with stress urinary incontinence (SUI. Patients and Methods. Between December 2006 and July 2007, 20 patients with anterior genital prolapse and voiding dysfunction were treated with the transobturator tension-free vaginal mesh (Prolift and concomitant tension-free vaginal tape-obturator (TVT-O. Sixteen patients had stress urinary incontinence and 4 patients were considered at risk for development of de novo stress incontinence after the prolapse is repaired. All patients underwent a complete urodynamic assessment. All the patients underwent pelvic examination 4–6 weeks after the operation, and anatomical and functional outcomes were recorded. Results. Twenty cystocoeles were repaired: 6 grade II, 12 grade III, and 2 grade IV. There were no vessel or bladder injuries. Eighteen patients had optimal anatomic results and 2 patients had persistent asymptomatic stage I prolapse. Conclusion. These preliminary results suggest that Prolift system offers a safe and effective treatment for female anterior vaginal wall prolapse. However, a long-term followup is necessary in order to support the good result maintenance.

  1. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  2. Maxillary obturator

    Directory of Open Access Journals (Sweden)

    Aruna Jawahirlal Bhandari

    2017-01-01

    Full Text Available Defects in the maxillary jaw can be congenital, developmental, acquired, traumatic or surgical involving the oral cavity and related anatomic structure. Absence or loss of some or all of the soft palate and / or hard palate results in insufficient structure or altered function of the remaining tissues. Defects can cause disruption of articulation and airflow during speech production and also nasal reflux during deglutition. Patients after surgical resection have altered anatomy due to scaring, tissue contracture, lack of bony support and tissue edema. These patients have problem of regurgitation of water and food through nose and difficulty in speech. These changes require the fabrication of prosthesis and also sometimes repeated prosthesis adjustments to confirm to the soft tissue changes. To prevent this and to help the patient in deglutition and speech defects must be restored with prosthesis. In such situation an obturator is designed to close the opening between the residual hard and / or soft palate and the pharynx. The prosthesis provided for these patients are called as obturators. An obturator is a prosthesis which is fabricated for the patients with the palatal defects in the form of cleft lip and palate, oroantral fistula or surgical resection after removable of pathology like tumor or cancer. This review article will highlight on the Prosthetic Rehabilitation of the maxillary defects and the types of obturators.

  3. Semiautomatic machine for turning inside out industrial leather gloves

    International Nuclear Information System (INIS)

    Aragón-Gonzalez, G; Cano-Blanco, M; León-Galicia, A; Medrano-Sierra, L F; Morales-Gómez, J R

    2015-01-01

    The last step in the industrial leather gloves manufacturing is to turn the inside out so that the sewing be in the inside of the glove. This work presents the design and testing of a machine for that purpose. In order to quantify the relevant variables, testing was performed with a prototype glove. The employed devices and the testing proceeding were developed experimentally. The obtained information was used to build the turning inside out machine. This machine works with pneumatic power to carry the inside out turning by means of double effect lineal actuators. It has two independent work stations that could be operated simultaneously by two persons, one in each station or in single mode operating one station by one person. The turning inside out cycle is started by means of directional control valves operated with pedals. The velocity and developed force by the actuators is controlled with typical pneumatic resources. The geometrical dimensions of the machine are: 1.15 m length; 0.71 m width and 2.15 m high. Its approximated weight is 120 kg. The air consumption is 5.4 fps by each working station with 60 psig work pressure. The turning inside out operation is 40 s for each industrial leather glove

  4. Time and Space Complexity of Inside-Out Macro Grammars

    NARCIS (Netherlands)

    Asveld, P.R.J.

    1980-01-01

    Starting form Fischer's IO Standard Form Theorem we show that for each inside-out (or IO-) macro language $L$ there exists a $\\lambda$-free IO macro grammar with the following property: for each $x$ in $L$ there is a derivation of $x$ of length at most linear in the length of $x$. Then we construct

  5. Windows Sharepoint Services 3.0 Inside Out

    CERN Document Server

    O' Connor, Errin

    2008-01-01

    Dig in-and learn how the experts use Windows SharePoint Services 3.0-from the inside out! This book packs hundreds of time-saving solutions, troubleshooting tips, and workarounds-all in concise, fast-answer format. You will learn how to simplify information sharing, make team collaboration more efficient, and improve your personal productivity. You'll discover how to design workflows and projects for SharePoint sites, manage design teams and source control, and use cascading style sheets to control site appearance. You'll get to explore new features for using Windows SharePoint Services with

  6. The transperiosteal "inside-out" occipital artery harvesting technique.

    Science.gov (United States)

    Benet, Arnau; Tabani, Halima; Ding, Xinmin; Burkhardt, Jan-Karl; Rodriguez Rubio, Roberto; Tayebi Meybodi, Ali; Nisson, Peyton; Kola, Olivia; Gandhi, Sirin; Yousef, Sonia; Lawton, Michael T

    2018-01-26

    OBJECTIVE The occipital artery (OA) is a frequently used donor vessel for posterior circulation bypass procedures due to its proximity to the recipient vessels and its optimal caliber, length, and flow rate. However, its tortuous course through multiple layers of suboccipital muscles necessitates layer-by-layer dissection. The authors of this cadaveric study aimed to describe a landmark-based novel anterograde approach to harvest OA in a proximal-to-distal "inside-out" fashion, which avoids multilayer dissection. METHODS Sixteen cadaveric specimens were prepared for surgical simulation, and the OA was harvested using the classic (n = 2) and novel (n = 14) techniques. The specimens were positioned three-quarters prone, with 45° contralateral head rotation. An inverted hockey-stick incision was made from the spinous process of C-2 to the mastoid tip, and the distal part of the OA was divided to lift up a myocutaneous flap, including the nuchal muscles. The OA was identified using the occipital groove (OG), the digastric muscle (DM) and its groove (DG), and the superior oblique muscle (SOM) as key landmarks. The OA was harvested anterogradely from the OG and within the flap until the skin incision was reached (proximal-to-distal technique). In addition, 35 dry skulls were assessed bilaterally (n = 70) to study additional craniometric landmarks to infer the course of the OA in the OG. RESULTS The OA was consistently found running in the OG, which was found between the posterior belly of the DM and the SOM. The mean total length of the mobilized OA was 12.8 ± 1.2 cm, with a diameter of 1.3 ± 0.1 mm at the suboccipital segment and 1.1 ± 0.1 mm at the skin incision. On dry skulls, the occipitomastoid suture (OMS) was found to be medial to the OG in the majority of the cases (68.6%), making it a useful landmark to locate the OG and thus the proximal OA. CONCLUSIONS The anterograde transperiosteal inside-out approach for harvesting the OA is a fast and easy technique

  7. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.

    Science.gov (United States)

    ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Elsergany, Ragheb; Hussein, Eman A

    2015-10-01

    The objective of the study was to compare the safety and efficacy of surgeon-tailored polypropylene mesh (STM) through tension-free vaginal tape-obturator (TVT-O) versus original TVT-O in the treatment of stress urinary incontinence (SUI) aiming to decrease the cost of treatment. This is important in developing countries due to limited health care resources. A retrospective cohort study was done at the Urology and Gynecology Departments (dual-center), Cairo University from May 2007 to June 2010. Women evaluated by cough stress test, Stress and Urge Incontinence and Quality of Life Questionnaire (SUIQQ), maximum flow rate (Qmax), and abdominal leak point pressure (ALPP) with follow-up for at least 48 months were included. Patients with post-void residual urine > 100 ml, bladder capacity TVT-O were inserted in 79 and 66 women, respectively. Intrinsic sphincter deficiency, ALPP, previous surgeries, associated urgency, urgency urinary incontinence (UUI), and prolapse were comparable in both groups. Operative duration was longer in STM by 10 min. No significant difference was found between both groups in complications (p = 0.462), cure (p = 0.654), and different indices of SUIQQ. In STM, 74 (93 %) were cured and 3 (4 %) improved, while SUI persisted in 2 (2 %) patients. In TVT-O, 59 (89 %) were cured and 4 (6 %) improved, while failure was detected in 3 (4 %) patients. The 5-year outcome is comparable between STM and TVT-O. Furthermore, STM is more economical due to our resterilizable modified helical passers and the cheap polypropylene mesh.

  8. Bacteria versus selenium: A view from the inside out

    Science.gov (United States)

    Staicu, Lucian; Oremland, Ronald S.; Tobe, Ryuta; Mihara, Hisaaki

    2017-01-01

    Bacteria and selenium (Se) are closely interlinked as the element serves both essential nutrient requirements and energy generation functions. However, Se can also behave as a powerful toxicant for bacterial homeostasis. Conversely, bacteria play a tremendous role in the cycling of Se between different environmental compartments, and bacterial metabolism has been shown to participate to all valence state transformations undergone by Se in nature. Bacteria possess an extensive molecular repertoire for Se metabolism. At the end of the 1980s, a novel mode of anaerobic respiration based on Se oxyanions was experimentally documented for the first time. Following this discovery, specific enzymes capable of reducing Se oxyanions and harvesting energy were found in a number of anaerobic bacteria. The genes involved in the expression of these enzymes have later been identified and cloned. This iterative approach undertaken outside-in led to the understanding of the molecular mechanisms of Se transformations in bacteria. Based on the extensive knowledge accumulated over the years, we now have a full(er) view from the inside out, from DNA-encoding genes to enzymes and thermodynamics. Bacterial transformations of Se for assimilatory purposes have been the object of numerous studies predating the investigation of Se respiration. Remarkable contributions related to the understating of the molecular picture underlying seleno-amino acid biosynthesis are reviewed herein. Under certain circumstances, Se is a toxicant for bacterial metabolism and bacteria have evolved strategies to counteract this toxicity, most notably by the formation of elemental Se (nano)particles. Several biotechnological applications, such as the production of functional materials and the biofortification of crop species using Se-utilizing bacteria, are presented in this chapter.

  9. Catechesis Inside Out A Hermeneutical Model for Catechesis in Parishes

    Directory of Open Access Journals (Sweden)

    Annemie Dillen

    2011-04-01

    Full Text Available Parochial catechesis in Belgium, especially in Flanders as the Dutch-speaking part of Belgium, is confronted with a lot of challenges. This text deals with three main thematic clusters. The fi rst cluster centres on the relation between ‘Christianity’ and ‘culture’ and its consequences for the content and the method of the catechesis. In a context where Christianity and culture are no longer intrinsically linked to each other, new models of catechesis have to be found. The authors propose a ‘hermeneutical model of catechesis’, whereby many elements of the surrounding culture and of the faith tradition(s are confronted with each other in a multidimensional way, challenging each other. In this vision, religious truth is not a set of dogmas that should be transmitted, but an open and ‘utopian’ search process that asks for new questions time and again. From a didactical as well as from a theological perspective this hermeneutical model offers new opportunities for catechesis. The second cluster can be summarized as ‘life-long’ and ‘life-wide’ learning. The authors argue that is it necessary to create vertical (intergenerational and horizontal (among a generation or a speci fi c group networks dealing with religious communication. Thereby they propose a speci fi c church organisation with lots of possibilities for cooperation between different parochial groups. The title of the article, catechesis inside out, refers to the vision that religious communication is not only a task inside church communities. The authors argue for open church communities daring to speak with people that hold to different world views. The second thematic cluster also deals with the organisation of the catechesis and more speci fi cally with the question of the target group or the age of those who are catechised. In a third movement the article deals with questions about fi nding ‘good’ catechists. At the end of the text the authors offer a

  10. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    Science.gov (United States)

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  11. Economic feasibility of producing inside-out beams from small-diameter logs

    Science.gov (United States)

    David W. Patterson; Richard A. Kluender; James E. Granskog

    2002-01-01

    Previous work has shown that it is technically feasible to produce inside-out (ISO) beams by taking small-diameter (5 to 7 in.) logs, slabbing four sides, quartering the cant, and turning the quarters inside out and gluing them together. After drying, the beams were found to be straight, with no cracks, and of equal or better mechanical properties than solid sawn...

  12. Inside Out

    Science.gov (United States)

    Jennings, Matt

    2011-01-01

    In a world ruled by digital communications, it can seem like there are almost as many methods, tools, and platforms to communicate with internal audiences as there are opinions and perspectives on how to do it effectively. Organizations of various sizes are struggling with how to reach their audiences' divided attention, and higher education…

  13. RTV-silikon sebagai Bahan Protesa Obturator Palatum

    OpenAIRE

    Chandrasegar, Akila

    2011-01-01

    Protesa Obturator palatum adalah protesa yang digunakan untuk menutup jaringan yang terbuka secara kongenital atau yang diperdapat, terutama bagian palatum keras atau lunak serta struktur alveolar yang berdekatan. Obturator palatum dapat diklasifikasikan berdasar pada tahap perawatannya yaitu obturator selama pembedahan (surgical obturator), obturator interim dan obturator definitif. Terdapat beberapa tipe obturator selain dari obturator palatum seperti obturator palato fari...

  14. Estudio de las emociones en los personajes animados de Inside Out/ Study of emotions in the animated characters from Inside Out

    OpenAIRE

    Leticia Porto Pedrosa

    2016-01-01

    Este artículo pretende mostrar la importancia de investigar las emociones a partir del cine de animación y su influencia en la audiencia infantil. Para ello, se lleva a cabo un recorrido a lo largo del tratamiento y la representación de las emociones encarnadas en los personajes animados de los largometrajes de Pixar. A través de la revisión bibliográfica y el análisis de contenido de la película Inside Out (2015), se profundiza en las principales emociones como la ...

  15. Estudio de las emociones en los personajes animados de Inside Out/ Study of emotions in the animated characters from Inside Out

    Directory of Open Access Journals (Sweden)

    Leticia Porto Pedrosa

    2016-01-01

    Full Text Available Este artículo pretende mostrar la importancia de investigar las emociones a partir del cine de animación y su influencia en la audiencia infantil. Para ello, se lleva a cabo un recorrido a lo largo del tratamiento y la representación de las emociones encarnadas en los personajes animados de los largometrajes de Pixar. A través de la revisión bibliográfica y el análisis de contenido de la película Inside Out (2015, se profundiza en las principales emociones como la tristeza y la alegría para comprender cuál es el papel social de esta dimensión esencial en el ser humano. The purpose of this paper is to discuss about the importance of investigating the emotions from the cartoon movies and its influence on the child audience. For this, in this article studies the treatment and representation of emotions on the characters of films Pixar Studios. Through literature review and analysis of content of the cartoon movie Inside Out (2015, it delves into the main emotions like sadness and joy to understand what the social role of this essential dimension of the human being.

  16. Turning Schools Inside Out: Connecting Schools and Communities through Public Arts and Literacies

    Science.gov (United States)

    Charest, Brian C.; Bell, Lauren D.; Gonzalez, Marialuisa; Parker, Veronica L.

    2014-01-01

    In this paper we tell a story about how we partnered with a Chicago high school in order to turn the school inside out by displaying larger-than-life teacher portraits and statements at street level throughout the community. This paper explores how public art and activism can help teachers and students develop notions of civic literacy and…

  17. My Dance and the Ideal Body: Looking at Ballet Practice from the Inside Out

    Science.gov (United States)

    Jackson, Jennifer

    2005-01-01

    This paper argues for a change of thinking about the "ideal body" in relation to ballet as a dance form and how it is studied. It distinguishes between spectator and practitioner perspectives on ballet, and draws on the practice of established dance artists and that of the author to write about the first-person experience--from the inside out.…

  18. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  20. The impact on growth of outside-in and inside-out innovation in SME networks

    DEFF Research Database (Denmark)

    Brink, Tove

    2014-01-01

    The purpose of this paper is to reveal what impact the dual approaches of outside-in and inside-out innovation have on growth in turnover in small and medium sized enterprises (SMEs) working together in network context. This is illustrated through research in three informal, Danish food industry...... networks with 60 SMEs responding. The research employs structural equation modelling for statistical analyses. The findings reveal that both the outside-in and the inside-out approaches have a significant positive impact on innovation and growth. The findings shed light on the need for combined dual...... on innovation and growth. A contribution is also made to the SME-network for organising the loosely coupled system in a dual approach....

  1. Inside-out electrical capacitance tomography for downhole multiphase flow evaluation

    DEFF Research Database (Denmark)

    Kjærsgaard-Rasmussen, Jimmy

    The management of a hydrocarbon reservoir is based on measurements made in and around the well. The available information is used as input into models of the reservoir, so as to operate the well in the most optimal way. A reservoir managers success thus depends on the quality and type...... and that the system is able to operate in temperatures of 120C. The image quality of the customized Landweber algorithm is superior to other reconstruction methods for the inside-out geometry. The system was tested in a well under surface conditions. Live tomography could be provided over the wireline...

  2. [A comparative study on treating femal stress urinary incontinence with TVT-Abbrevo and TVT-Obturator].

    Science.gov (United States)

    Li, W L; Lu, Z W; Li, F P; Yu, H Y

    2016-07-26

    To compare the effectiveness and complications of TVT-Abbrevo (tension-free vaginal tape-Abbrevo) and TVT-Obturator (tension-free vaginal tape-obturator) for the treatment of female stress urinary incontinence (SUI). From Nov.2012 to Nov.2013, 117 patients suffering from SUI were treated with TVT-Abbrebo (n=79) or TVT-Obturator (n=38) procedure, the clinical efficacy and operation-correlated complications were observed. A total of 117 cases, 107 cases of urinary incontinence symptoms disappeared completely, 10 cases were improved. 72 cases (91.1%) were cured and 7 cases (8.9%) were improved in TVT-Abbrevo group; 35 cases (92.1%) were cured and 3 cases (7.9%) were improved in TVT-Obturator group. No significant differences could be found for the curing rates between two groups (P>0.05). Compared with the TVT-Obturator group, the TVT-Abbrevo group had less patients complaining of inner thigh pain at 24 h and 1 w after surgery (PTVT-Abbrevo and TVT-Obturator group (P>0.05). No intraoperative complications such as blood vessel, nerve, bladder damage were recorded and no postoperative retropubic hematoma, tape adjustment and other complications occurred in two goups. No recurrence after 1 year follow-up. The study shows that TVT-Abbrevo procedure is safe and efficacy in treatment of SUI, and associated with low incidence of recent postoperative inner thigh pain.

  3. The development of the clean burning inside-out flame in noncatalytic woodstoves

    International Nuclear Information System (INIS)

    Myren, A.T. Jr.

    1992-01-01

    The promulgation of phased emissions standards for woodstoves by the Oregon Department of Environmental Quality (DEQ) in 1984, the Colorado Department of Health in 1985 and the United States Environmental Protection Agency (EPA) in 1988, caused woodstove manufacturers to develop new noncatalytic products designed to comply with these regulations. This paper looks at the various low emission noncatalytic wood combustion engineering concepts/principles/ideas that led to the development of a clean burning inside-out flame (preheated air is injected into a gas stream containing the fuel to be burned) that has allowed manufacturers to consistently develop units with weighted average emission rates below the EPA Phase II (1990) standard for catalytic woodstoves and as low as 2.1 g/hr

  4. Prospective study of the " Inside-Out" arthroscopic ankle ligament technique: Preliminary result.

    Science.gov (United States)

    Nery, Caio; Fonseca, Lucas; Raduan, Fernando; Moreno, Marcus; Baumfeld, Daniel

    2017-03-22

    Lateral ankle ligament injury is among the most common orthopedic injuries. The objective of this study is to present the preliminary prospective results of treatment using the "Inside-Out" variant of the fully arthroscopic Broström-Gould technique. Twenty six patients were included: 20 male and 6 female, aged 19-60 years, mean 41 years. All patients had positive "anterior drawer" and "talar tilt" tests. When necessary, cartilage injuries were treated with microfracture and arthroscopic resection for anterior impingement; three patients had hindfoot varus, on whom Dwyer osteotomy was performed; one patient had peroneal tendinopathy and was treated with tendoscopic debridement and another one had partial injury of the deltoid ligament, which was treated by direct repair. Two arthroscopic surgery portals were used; the anteromedial and anterolateral. After careful inspection of the joint, the anterior surface of the fibula was cleaned to resect the remains of the anterior talo-fibular ligament. An anchor with two sutures was placed on the anterior aspect of the fibula, 1cm from the distal apex of the malleolus. The sutures were passed through the remnant of the anterior talo-fibular ligament as well as the extensor retinaculum using special curved needles. Duncan knots were used to tie the ligament and the inferior extensor retinaculum while the ankle was kept in a neutral position. Patients were kept immobilized non-weight bearing for 2 weeks and were then allowed to start weight bearing in a removable protective boot for 4 weeks. The patients were able to return to sporting activities 6 months after surgery. After a mean follow-up of 27 months (range 21-36 months), patients were functionally evaluated using the American Orthopedics Foot and Ankle Society (AOFAS) ankle score. The mean preoperative value was 58 points, while the mean postoperative value increased to 90 points. One patient had paresthesia in the superficial fibular nerve area, which resolved

  5. The inside-out supercapacitor: induced charge storage in reduced graphene oxide.

    Science.gov (United States)

    Martin, Samuel T; Akbari, Abozar; Chakraborty Banerjee, Parama; Neild, Adrian; Majumder, Mainak

    2016-11-30

    Iontronic circuits are built using components which are analogous to those used in electronic circuits, however they involve the movement of ions in an electrolyte rather than electrons in a metal or semiconductor. Developments in these circuits' performance have led to applications in biological sensing, interfacing and drug delivery. While transistors, diodes and elementary logic circuits have been demonstrated for ionic circuits if more complex circuits are to be realized, the precident set by electrical circuits suggests that a component which is analogous to an electrical capacitor is required. Herein, an ionic supercapacitor is reported, our experiments show that charge may be stored in a conductive porous reduced graphene oxide film that is contacted by two isolated aqueous solutions and that this concept extends to an arbitrary polarizable sample. Parametric studies indicate that the conductivity and porosity of this film play important roles in the resultant device's performance. This ionic capacitor has a specific capacitance of 8.6 F cm -3 at 1 mV s -1 and demonstrates the ability to filter and smooth signals in an electrolyte at a variety of low frequencies. The device has the same interfaces as a supercapacitor but their arrangement is changed, hence the name inside-out supercapacitor.

  6. INSIDE-OUT PLANET FORMATION. III. PLANET–DISK INTERACTION AT THE DEAD ZONE INNER BOUNDARY

    International Nuclear Information System (INIS)

    Hu, Xiao; Tan, Jonathan C.; Chatterjee, Sourav; Zhu, Zhaohuan

    2016-01-01

    The Kepler mission has discovered more than 4000 exoplanet candidates. Many of them are in systems with tightly packed inner planets. Inside-out planet formation (IOPF) has been proposed as a scenario to explain these systems. It involves sequential in situ planet formation at the local pressure maximum of a retreating dead zone inner boundary (DZIB). Pebbles accumulate at this pressure trap, which builds up a pebble ring and then a planet. The planet is expected to grow in mass until it opens a gap, which helps to both truncate pebble accretion and also induce DZIB retreat that sets the location of formation of the next planet. This simple scenario may be modified if the planet undergoes significant migration from its formation location. Thus, planet–disk interactions play a crucial role in the IOPF scenario. Here we present numerical simulations that first assess the degree of migration for planets of various masses that are forming at the DZIB of an active accretion disk, where the effective viscosity is undergoing a rapid increase in the radially inward direction. We find that torques exerted on the planet by the disk tend to trap the planet at a location very close to the initial pressure maximum where it formed. We then study gap opening by these planets to assess at what mass a significant gap is created. Finally, we present a simple model for DZIB retreat due to penetration of X-rays from the star to the disk midplane. Overall, these simulations help to quantify both the mass scale of first (“Vulcan”) planet formation and the orbital separation to the location of second planet formation

  7. Silicon anode materials with ultra-low resistivity from the inside out for lithium ion batteries

    Science.gov (United States)

    Xu, Guojun; Jin, Chenxin; Liu, Liekai; Lan, Yu; Yue, Zhihao; Li, Xiaomin; Sun, Fugen; Huang, Haibin; Zhou, Lang

    2017-12-01

    Broken silicon (Si) wafers with electrical resistivity of 1 and 0.001 Ω cm were respectively ball-milled to Si particles with median diameters of less than 1 μm. Both these two types of Si particles were deposited with silver (Ag) nanoparticles by self-selective electroless deposition method. 1-Ω cm-Si particles, 0.001-Ω cm-Si particles, Ag-deposited 1-Ω cm-Si particles and Ag-deposited 0.001-Ω cm-Si particles were, respectively, mixed with graphite particles in weight ratio of 1:9 to form four types of Si-C anode materials and then they were assembled into coin cells. The experimental results indicate that the Ag-deposited 0.001-Ω cm-Si sample shows the higher capacity, better rate and cycle performance than other three samples, due to the high conductivity of Ag-deposited 0.001-Ω cm-Si sample from the inside out. At the current density of 750 mA g-1, the discharge capacity gap of Ag-deposited 0.001-Ω cm-Si sample and 0.001-Ω cm-Si sample is as high as 141.7 mA h g-1, which is almost equal to the discharge capacity of the latter. Besides, the discharge capacity retention ratio of Ag-deposited 0.001-Ω cm-Si sample after 50 cycles is 70%, which is 23.5% higher than that of 0.001-Ω cm-Si sample.

  8. Inside-out Planet Formation. IV. Pebble Evolution and Planet Formation Timescales

    Science.gov (United States)

    Hu, Xiao; Tan, Jonathan C.; Zhu, Zhaohuan; Chatterjee, Sourav; Birnstiel, Tilman; Youdin, Andrew N.; Mohanty, Subhanjoy

    2018-04-01

    Systems with tightly packed inner planets (STIPs) are very common. Chatterjee & Tan proposed Inside-out Planet Formation (IOPF), an in situ formation theory, to explain these planets. IOPF involves sequential planet formation from pebble-rich rings that are fed from the outer disk and trapped at the pressure maximum associated with the dead zone inner boundary (DZIB). Planet masses are set by their ability to open a gap and cause the DZIB to retreat outwards. We present models for the disk density and temperature structures that are relevant to the conditions of IOPF. For a wide range of DZIB conditions, we evaluate the gap-opening masses of planets in these disks that are expected to lead to the truncation of pebble accretion onto the forming planet. We then consider the evolution of dust and pebbles in the disk, estimating that pebbles typically grow to sizes of a few centimeters during their radial drift from several tens of astronomical units to the inner, ≲1 au scale disk. A large fraction of the accretion flux of solids is expected to be in such pebbles. This allows us to estimate the timescales for individual planet formation and the entire planetary system formation in the IOPF scenario. We find that to produce realistic STIPs within reasonable timescales similar to disk lifetimes requires disk accretion rates of ∼10‑9 M ⊙ yr‑1 and relatively low viscosity conditions in the DZIB region, i.e., a Shakura–Sunyaev parameter of α ∼ 10‑4.

  9. VULCAN PLANETS: INSIDE-OUT FORMATION OF THE INNERMOST SUPER-EARTHS

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Sourav [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA), Physics and Astronomy, Northwestern University, Evanston, IL 60208 (United States); Tan, Jonathan C., E-mail: sourav.chatterjee@northwestern.edu, E-mail: jt@astro.ufl.edu [Departments of Astronomy and Physics, University of Florida, Gainesville, FL 32611 (United States)

    2015-01-10

    The compact multi-transiting systems discovered by Kepler challenge traditional planet formation theories. These fall into two broad classes: (1) formation further out followed by migration and (2) formation in situ from a disk of gas and planetesimals. In the former, an abundance of resonant chains is expected, which the Kepler data do not support. In the latter, required disk mass surface densities may be too high. A recently proposed mechanism hypothesizes that planets form in situ at the pressure trap associated with the dead-zone inner boundary (DZIB) where radially drifting ''pebbles'' accumulate. This scenario predicts planet masses (M{sub p} ) are set by the gap-opening process that then leads to DZIB retreat, followed by sequential, inside-out planet formation (IOPF). For typical disk accretion rates, IOPF predictions for M{sub p} , M{sub p} versus orbital radius r, and planet-planet separations are consistent with observed systems. Here we investigate the IOPF prediction for how the masses, M{sub p,} {sub 1}, of the innermost (''Vulcan'') planets vary with r. We show that for fiducial parameters, M {sub p,} {sub 1} ≅ 5.0(r/0.1 AU) M {sub ⊕}, independent of the disk's accretion rate at time of planet formation. Then, using Monte Carlo sampling of a population of these innermost planets, we test this predicted scaling against observed planet properties, allowing for intrinsic dispersions in planetary densities and Kepler's observational biases. These effects lead to a slightly shallower relation M{sub p,} {sub 1}∝r {sup 0.9} {sup ±} {sup 0.2}, which is consistent with M{sub p,} 1∝r {sup 0.7} {sup ±} {sup 0.2} of the observed Vulcans. The normalization of the relation constrains the gap-opening process, favoring relatively low viscosities in the inner dead zone.

  10. Persistent groin pain following a trans-obturator sling procedure for stress urinary incontinence: a diagnostic and therapeutic challenge

    NARCIS (Netherlands)

    Hazewinkel, Menke H.; Hinoul, Piet; Roovers, Jan-Paul

    2009-01-01

    Groin pain after a tension-free vaginal tape-obturator (TVT-O) procedure can occur but mostly disappears within 4 weeks. Persistent groin pain is extremely rare and there is a paucity of literature on how to diagnose and manage this adverse event. We present two cases with severe persistent groin

  11. Comparison of the clinical and quality-of-life outcomes after the inside-out TVT-O procedure with or without concomitant transvaginal gynaecological surgery.

    Science.gov (United States)

    Cho, M K; Kim, C H; Kang, W D; Kim, J W; Kim, S M; Kim, Y H

    2012-04-01

    The study was undertaken to compare the clinical and quality-of-life (QoL) outcomes of the inside-out transobturator vaginal tape (TVT-O)-only procedures and TVT-O procedures with concomitant transvaginal gynaecological surgery for the treatment of stress urinary incontinence (SUI). A review of charts from January 2006 to March 2010 identified 305 patients with urodynamic stress incontinence for whom we performed the TVT-O. Of the initial 305 patients, 272 (89.2%) were re-examined for complications 1 month, 4 months, 1 year and 2-4 years postoperatively (122 TVT-O only; 150 TVT-O + other transvaginal gynaecological surgery). They were also evaluated with the Urogenital Distress Inventory Questionnaire (UDI-6) and the Incontinence Impact Questionnaire (IIQ-7) 1-4 years after the procedure. The median follow-up was 37.3 months. The success rate was 89.3% in the TVT-O-only group vs 93.3% in the TVT-O with concomitant gynaecological surgery group (p =0.729). The QoL score was quite good for 91.8% of the TVT-O-only patients and for 96.7% of the TVT-O with concomitant gynaecologic surgery patients (p =0.405). In conclusion, gynaecological operations performed concomitantly with the TVT-O procedure do not affect the clinical and QoL outcomes of the TVT-O procedure.

  12. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Galia, Massimo; Lo Re, Giuseppe; La Grutta, Ludovico; Grassi, Roberto; Midiri, Massimo

    2007-01-01

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma

  13. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: tv.bartolotta@unipa.it; Taibbi, Adele [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: taibbi_adele@yahoo.it; Galia, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mgalia@yahoo.com; Lo Re, Giuseppe [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: giuseppe.lore12@tin.it; La Grutta, Ludovico [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: lagrutta@mbox.infcom.it; Grassi, Roberto [Institute of Radiology, Second University of Naples, Piazza Miraglia, 80138 Naples (Italy)], E-mail: roberto.grassi@libero.it; Midiri, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mmidiri@hotmail.com

    2007-12-15

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma.

  14. Palatal obturators in patients after maxillectomy.

    Science.gov (United States)

    Cardelli, P; Bigelli, E; Vertucci, V; Balestra, F; Montani, M; DE Carli, S; Arcuri, C

    2014-01-01

    Prosthodontic management of palatal defects is fundamental to improve patient's life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators.

  15. A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

    Science.gov (United States)

    Ramappa, Arun J; Chen, Alvin; Hertz, Benjamin; Wexler, Michael; Grimaldi Bournissaint, Leandro; DeAngelis, Joseph P; Nazarian, Ara

    2014-01-01

    Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. Controlled laboratory study. Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.

  16. Psychologiczna praca z filmem "W głowie się nie mieści" ("Inside Out"

    Directory of Open Access Journals (Sweden)

    Michał Brol

    2017-08-01

    Full Text Available The article focuses on the meaning of the animation Inside Out, especially concerning its educational message. Emotions in human’s life are the main topic of this analysis. Furthermore, we share our views on the psychological role of the movie used while teaching, that are based on the gained knowledge and practical experience. In addition to that, we intend to explain why work with this specific film makes such a great example of the challenges standing before everyone who has decided to use it in one’s workshops, therapy or psychoeducational work.

  17. Herniography off femoral, obturator and perineal hernias

    International Nuclear Information System (INIS)

    Ekberg, O.; Nordblom, I.; Fork, F.T.; Gullmo, A.

    1985-01-01

    Positive contrast herniography was used in the workup of 550 patients with unclear groin pain. The majority of these patients had rather characteristic hernias of indirect, direct or femoral type. However, now and then diagnostic problems arose. A femoral hernia may look like a direct or even obturator hernia. There is also a variety of multilocular femoral hernias and other types. A femoral hernia may be present together with other hernias in the ipsilateral or contralateral groin. Obturator hernias are usually small but are always confined to the obturator canal laterally in the obturator foramen. Abnormalities in the pouch of Douglas may include a deep rectogenital pouch, diverticula and true herniations. These uncommon herniographic findings are described and discussed. (orig.) [de

  18. Two-piece hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Subramaniam Elangovan

    2011-01-01

    Full Text Available There are various types of obturator fabrication achievable by prosthodontist. Maxillectomy, which is a term used by head and neck surgeons and prosthodontists to describe the partial or total removal of the maxilla in patients suffering from benign or malignant neoplasms is a defect for which to provide an effective obturator is a difficult task for the maxillofacial prosthodontist. Multidisciplinary treatment planning is essential to achieve adequate retention and function for the prosthesis. Speech is often unintelligible as a result of the marked defects in articulation and nasal resonance. This paper describes how to achieve the goal for esthetics and phonetics and also describes the fabrication of a hollow obturator by two piece method, which is simple and maybe used as definitive obturator for maximum comfort of the patient.

  19. SPEECH EVALUATION WITH AND WITHOUT PALATAL OBTURATOR IN PATIENTS SUBMITTED TO MAXILLECTOMY

    Science.gov (United States)

    de Carvalho-Teles, Viviane; Pegoraro-Krook, Maria Inês; Lauris, José Roberto Pereira

    2006-01-01

    Most patients who have undergone resection of the maxillae due to benign or malignant tumors in the palatomaxillary region present with speech and swallowing disorders. Coupling of the oral and nasal cavities increases nasal resonance, resulting in hypernasality and unintelligible speech. Prosthodontic rehabilitation of maxillary resections with effective separation of the oral and nasal cavities can improve speech and esthetics, and assist the psychosocial adjustment of the patient as well. The objective of this study was to evaluate the efficacy of the palatal obturator prosthesis on speech intelligibility and resonance of 23 patients with age ranging from 18 to 83 years (Mean = 49.5 years), who had undergone inframedial-structural maxillectomy. The patients were requested to count from 1 to 20, to repeat 21 words and to spontaneously speak for 15 seconds, once with and again without the prosthesis, for tape recording purposes. The resonance and speech intelligibility were judged by 5 speech language pathologists from the tape recordings samples. The results have shown that the majority of patients (82.6%) significantly improved their speech intelligibility, and 16 patients (69.9%) exhibited a significant hypernasality reduction with the obturator in place. The results of this study indicated that maxillary obturator prosthesis was efficient to improve the speech intelligibility and resonance in patients who had undergone maxillectomy. PMID:19089242

  20. Galaxy evolution. Evidence for mature bulges and an inside-out quenching phase 3 billion years after the Big Bang.

    Science.gov (United States)

    Tacchella, S; Carollo, C M; Renzini, A; Förster Schreiber, N M; Lang, P; Wuyts, S; Cresci, G; Dekel, A; Genzel, R; Lilly, S J; Mancini, C; Newman, S; Onodera, M; Shapley, A; Tacconi, L; Woo, J; Zamorani, G

    2015-04-17

    Most present-day galaxies with stellar masses ≥10(11) solar masses show no ongoing star formation and are dense spheroids. Ten billion years ago, similarly massive galaxies were typically forming stars at rates of hundreds solar masses per year. It is debated how star formation ceased, on which time scales, and how this "quenching" relates to the emergence of dense spheroids. We measured stellar mass and star-formation rate surface density distributions in star-forming galaxies at redshift 2.2 with ~1-kiloparsec resolution. We find that, in the most massive galaxies, star formation is quenched from the inside out, on time scales less than 1 billion years in the inner regions, up to a few billion years in the outer disks. These galaxies sustain high star-formation activity at large radii, while hosting fully grown and already quenched bulges in their cores. Copyright © 2015, American Association for the Advancement of Science.

  1. Oral function after maxillectomy and reconstruction with an obturator

    NARCIS (Netherlands)

    Kreeft, A.M.; Krap, M.; Wismeijer, D.; Speksnijder, C.M.; Smeele, L.E.; Bosch, S.D.; Muijen, M.S.A.; Balm, A.J.M.

    2012-01-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and

  2. MR Imaging Features of Obturator Internus Bursa of the Hip

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Jong Oh

    2008-01-01

    The authors report two cases with distension of the obturator internus bursa identified on MR images, and describe the location and characteristic features of obturator internus bursitis; the 'boomerang'-shaped fluid distension between the obturator internus tendon and the posterior grooved surface of the ischium

  3. MR Imaging Features of Obturator Internus Bursa of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Jong Oh [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2008-08-15

    The authors report two cases with distension of the obturator internus bursa identified on MR images, and describe the location and characteristic features of obturator internus bursitis; the 'boomerang'-shaped fluid distension between the obturator internus tendon and the posterior grooved surface of the ischium

  4. Rigging dark haloes: why is hierarchical galaxy formation consistent with the inside-out build-up of thin discs?

    Science.gov (United States)

    Pichon, C.; Pogosyan, D.; Kimm, T.; Slyz, A.; Devriendt, J.; Dubois, Y.

    2011-12-01

    State-of-the-art hydrodynamical simulations show that gas inflow through the virial sphere of dark matter haloes is focused (i.e. has a preferred inflow direction), consistent (i.e. its orientation is steady in time) and amplified (i.e. the amplitude of its advected specific angular momentum increases with time). We explain this to be a consequence of the dynamics of the cosmic web within the neighbourhood of the halo, which produces steady, angular momentum rich, filamentary inflow of cold gas. On large scales, the dynamics within neighbouring patches drives matter out of the surrounding voids, into walls and filaments before it finally gets accreted on to virialized dark matter haloes. As these walls/filaments constitute the boundaries of asymmetric voids, they acquire a net transverse motion, which explains the angular momentum rich nature of the later infall which comes from further away. We conjecture that this large-scale driven consistency explains why cold flows are so efficient at building up high-redshift thin discs inside out.

  5. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  6. Predictors of obturator functioning and satisfaction in Turkish patients using an obturator prosthesis after maxillectomy.

    Science.gov (United States)

    Ozdemir-Karatas, Meltem; Balik, Ali; Evlioglu, Gülümser; Uysal, Ömer; Peker, Kadriye

    2018-03-01

    The aim of this study was to determine the sociodemographic, behavioral, and clinical factors affecting obturator function and satisfaction using the obturator functioning scale (OFS) in maxillectomy patients rehabilitated with obturator prostheses. The study sample consisted of 41 maxillectomy patients. The OFS was translated into Turkish and adapted for assessing obturator functioning and patient satisfaction among Turkish patients. Data were collected from patients' medical records and self-completed questionnaires, including the Turkish version of the OFS, sociodemographic and behavioral characteristics. Descriptive statistics, Mann-Whitney U test, Spearman's correlation coefficient, and backward stepwise multiple linear regression were used for data analysis. Internal consistency (Cronbach's alpha = 0.85) and test-retest reliability (intraclass correlation coefficient = 0.86) were acceptable for the OFS. The most frequently reported problem was "difficulty chewing." Bivariate analysis revealed significant differences in total OFS scores in terms of surgery type, defect size, and education level, except for the other clinical and sociodemographic characteristics and behavioral factors. Education level and surgery type were found to be the most important predictors of patient satisfaction and functioning of the obturator. The Turkish version of the OFS might be a useful tool for clinicians to identify patients who are at risk for poor functioning of the obturator, lack of satisfaction, and unmet needs. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. INSIDE OUT AND UPSIDE DOWN: TRACING THE ASSEMBLY OF A SIMULATED DISK GALAXY USING MONO-AGE STELLAR POPULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Bird, Jonathan C.; Kazantzidis, Stelios; Weinberg, David H. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Guedes, Javiera [Institute for Astronomy, ETH Zuerich, Wolgang-Pauli-Strasse 27, CH-8093 Zuerich (Switzerland); Callegari, Simone [Anthropology Institute and Museum, University of Zuerich, Winterthurerstrasse 190, CH-8057 Zuerich (Switzerland); Mayer, Lucio [Institute for Theoretical Physics, University of Zuerich, Winterthurerstrasse 190, CH-8057 Zuerich (Switzerland); Madau, Piero [Department of Astronomy and Astrophysics, University of California, 1156 High Street, Santa Cruz, CA 95064 (United States)

    2013-08-10

    We analyze the present day structure and assembly history of a high-resolution hydrodynamic simulation of the formation of a Milky-Way-(MW)-like disk galaxy, from the ''Eris'' simulation suite, dissecting it into cohorts of stars formed at different epochs of cosmic history. At z = 0, stars with t{sub form} < 2 Gyr mainly occupy the stellar spheroid, with the oldest (earliest forming) stars having more centrally concentrated profiles. The younger age cohorts populate disks of progressively longer radial scale lengths and shorter vertical scale heights. At a given radius, the vertical density profiles and velocity dispersions of stars vary smoothly as a function of age, and the superposition of old, vertically extended and young, vertically compact cohorts gives rise to a double-exponential profile like that observed in the MW. Turning to formation history, we find that the trends of spatial structure and kinematics with stellar age are largely imprinted at birth, or immediately thereafter. Stars that form during the active merger phase at z > 3 are quickly scattered into rounded, kinematically hot configurations. The oldest disk cohorts form in structures that are radially compact and relatively thick, while subsequent cohorts form in progressively larger, thinner, colder configurations from gas with increasing levels of rotational support. The disk thus forms ''inside out'' in a radial sense and ''upside down'' in a vertical sense. Secular heating and radial migration influence the final state of each age cohort, but the changes they produce are small compared to the trends established at formation. The predicted correlations of stellar age with spatial and kinematic structure are in good qualitative agreement with the correlations observed for mono-abundance stellar populations in the MW.

  8. Star formation is boosted (and quenched) from the inside-out: radial star formation profiles from MaNGA

    Science.gov (United States)

    Ellison, Sara L.; Sánchez, Sebastian F.; Ibarra-Medel, Hector; Antonio, Braulio; Mendel, J. Trevor; Barrera-Ballesteros, Jorge

    2018-02-01

    The tight correlation between total galaxy stellar mass and star formation rate (SFR) has become known as the star-forming main sequence. Using ˜487 000 spaxels from galaxies observed as part of the Sloan Digital Sky Survey Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey, we confirm previous results that a correlation also exists between the surface densities of star formation (ΣSFR) and stellar mass (Σ⋆) on kpc scales, representing a `resolved' main sequence. Using a new metric (ΔΣSFR), which measures the relative enhancement or deficit of star formation on a spaxel-by-spaxel basis relative to the resolved main sequence, we investigate the SFR profiles of 864 galaxies as a function of their position relative to the global star-forming main sequence (ΔSFR). For galaxies above the global main sequence (positive ΔSFR) ΔΣSFR is elevated throughout the galaxy, but the greatest enhancement in star formation occurs at small radii (<3 kpc, or 0.5Re). Moreover, galaxies that are at least a factor of 3 above the main sequence show diluted gas phase metallicities out to 2Re, indicative of metal-poor gas inflows accompanying the starbursts. For quiescent/passive galaxies that lie at least a factor of 10 below the star-forming main sequence, there is an analogous deficit of star formation throughout the galaxy with the lowest values of ΔΣSFR in the central 3 kpc. Our results are in qualitative agreement with the `compaction' scenario in which a central starburst leads to mass growth in the bulge and may ultimately precede galactic quenching from the inside-out.

  9. Tape transport mechanism

    International Nuclear Information System (INIS)

    Groh, E.F.; McDowell, W.; Modjeski, N.S.; Keefe, D.J.; Groer, P.

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer

  10. Obturator Definitive Mandibula Post Hemimandibulectomy Sinistra

    Directory of Open Access Journals (Sweden)

    Paul Sugiyo

    2012-12-01

    Full Text Available Latar Belakang. Operasi bedah pemotongan mandibula pada kasus tumor jinak maupun tumor ganas dapat menyebabkan deviasi mandibula. Tindakan perawatan bedah tergantung pada lokasi dan perluasan tumor mandibula, tindakan perawatan bedah tersebut meliputi bedah marginal, segmental, hemimandibulectomy, dan total mandibulectomy. Tujuan. Makalah ini menjelaskan tentang perawatan rehabilitasi dengan obturator definitive mandibula. Para klinisi harus menunggu masa penyembuhan yang sempurna sebelum disarankan untuk dibuatkan onturator definitive mandibula. Sejak awal penyembuhan diperlukan intervensi prostodontis untuk mencegah deviasi mandibula. Protesa ini membantu pergerakan mandibula secara normal tanpa terjadi penyimpangan pada fungsi bicara dan pengunyahan. Laporan Kasus. Pada bulan Maret 2012, pasien laki-laki, berumur 46 tahun datang ke RSGM Bagian Prostodonsia atas rujukan dari RS. Dr. Sardjito Bagian Bedah Mulut setelah dilakukan operasi tumor ameloblastoma mandibula sinistra (post hemimandibulectomy mandibula sinistra dengan pemasangan plat rekonstruksi tiga bulan sebelumnya untuk dibuatkan obturator definitive mandibula. Pasien mengeluh bibir bawah sebelah kiri sering tergigit, fungsi bicara, fungsi pengunyahan, dan penampilannya terganggu. Hasil. Setelah dilakukan perawatan dengan memakai obturator definitive mandibula dalam kurun waktu 8 bulan, hingga saat ini hasil perawatan ini dapat mengembalikan fungsi bicara, fungsi pengunyahan, dan fungsi estetik sehingga pasien merasa lebih nyaman dan percaya diri. Kesimpulan. Deviasi mandibula setelah operasi hemimandibulectomy diatasi dengan bedah rekonstruksi menggunakan plat rekonstruksi, kemudian segera setelah penyembuhan perlu melibatkan prostodontis untuk pemasangan obturator definitive mandibula.    Background. Surgical restion of the mandible due to presence of benign or malignant tumor is the common cause of the mandibular deviation. Depending upon the location and extent of the tumor in

  11. A Contact Pressure Analysis Comparing an All-Inside and Inside-Out Surgical Repair Technique for Bucket-Handle Medial Meniscus Tears.

    Science.gov (United States)

    Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B

    2017-10-01

    To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P contact pressure at all flexion angles (all P contact pressure at all flexion angles (all P contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P contact area at 60° and 90° and peak contact pressure at 90° (both P contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of

  12. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  13. Obturator hernia: a rare case of acute mechanical intestinal obstruction.

    Science.gov (United States)

    Aydin, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  14. Obturator Hernia: A Rare Case of Acute Mechanical Intestinal Obstruction

    Directory of Open Access Journals (Sweden)

    Ibrahim Aydin

    2013-01-01

    Full Text Available Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  15. Tape dig selv!

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  16. Obturator foramen dissection for excision of symptomatic transobturator mesh.

    Science.gov (United States)

    Reynolds, W Stuart; Kit, Laura Chang; Kaufman, Melissa R; Karram, Mickey; Bales, Gregory T; Dmochowski, Roger R

    2012-05-01

    Groin pain after transobturator synthetic mesh placement can be recalcitrant to conservative therapy and ultimately requires surgical excision. We describe our experiences with and technique of obturator foramen dissection for mesh excision. The records of 8 patients treated from 2005 to 2010, were reviewed. Obturator dissection was performed via a lateral groin incision over the inferior pubic ramus at the level of the obturator foramen, typically in conjunction with orthopedic surgery. Five patients had transobturator mid urethral sling surgery for stress urinary incontinence, 2 had mid urethral sling and trocar based anterior vaginal wall mesh kits with transobturator passage of mesh arms for stress urinary incontinence and pelvic organ prolapse, and 1 had an anterior vaginal wall mesh kit for pelvic organ prolapse. Patients had 0 to 2 prior transvaginal mesh excisions before obturator surgery. All patients presented with intractable pain in the area of the obturator foramen and/or medial groin for which conservative treatment measures had failed. Six patients underwent concurrent vaginal and obturator dissection and 2 underwent obturator dissection alone. In all cases residual mesh (3 to 11 cm) was identified and excised from the obturator foramen. Mesh was closely associated to or traversing the adductor longus muscle and tendon with significant fibrous reaction in all cases. Postoperatively 5 patients were cured of pain and/or infection, and 3 reported no or some improvement at a mean followup of 6 months (range 1 to 12). Our experience suggests that surgical excision of residual mesh can alleviate many of the symptoms in many patients. In all cases mesh remnants were identified and removed, and typically involved neuromuscular structures adjacent to the obturator foramen. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. A Comparative Prospective Study of Two Different Treatment Sequences i.e. Bottom Up-Inside Out and Topdown-Outside in, in the Treatment of Panfacial Fractures.

    Science.gov (United States)

    Degala, Saikrishna; Sundar, S Shyam; Mamata, K S

    2015-12-01

    To compare the sequence bottom-up inside-out with top-down outside-in, in the treatment of pan facial fractures and to evaluate the outcome of these approaches. The data from 11 patients with panfacial fracture are prospectively analysed. Five cases are treated with bottom-up approach and six patients with top-down approach. There were 11 male patients (six in top-down approach and five in bottom-up approach), ranging in age from 24 to 50 years. All injuries were result of RTA (n = 11, 100 %). Final treatment outcome was excellent in 3 (50 %), 1 (16 %) good and 2 (32 %) cases were fair in topdown approach, 3 (60 %) excellent and 2 (40 %) fair in bottom up approach with contingency coefficient value (P reconstruction of the remaining. Choice of the bottom-up inside-out or top-down outside-in sequence should be according to the pattern of fractures and preference of the surgeon. However, further controlled clinical trials, comparative studies with a larger sample size would be better to evaluate the final clinical outcome of individual techniques.

  18. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  19. Libraries from the Inside Out.

    Science.gov (United States)

    Cohen, Elaine; And Others

    1989-01-01

    This annual report on library facilities and furnishings includes articles on: (1) designing libraries that are both handsome and functional; (2) functional use of color and light in library interior design; (3) creating user-friendly libraries; and (4) the seven deadly sins of architects. An eight-page section of photographs is included. (MES)

  20. Candida albicans in patients with oronasal communication and obturator prostheses

    OpenAIRE

    MATTOS, Beatriz Silva Câmara; SOUSA, Andréa Alves de; MAGALHÃES, Marina Helena C. G. de; ANDRÉ, Marcia; BRITO E DIAS, Reinaldo

    2009-01-01

    Patients using obturator prostheses often present denture-induced stomatitis. In order to detect the presence of oral Candida albicans in patients with oronasal communications and to evaluate the effectiveness of a topical antifungal treatment, cytological smears obtained from the buccal and palatal mucosa of 10 adult patients, and from the nasal acrylic surface of their obturator prostheses were examined. A therapeutic protocol comprising the use of oral nystatin (Mycostatin®) and prosthesis...

  1. Caught (Unfortunately) on Tape

    Science.gov (United States)

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  2. Speech rehabilitation of maxillectomy patients with hollow bulb obturator.

    Science.gov (United States)

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-09-01

    To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  3. Speech rehabilitation of maxillectomy patients with hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Pravesh Kumar

    2012-01-01

    Full Text Available Aim: To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. Materials and Methods: A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery, after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. Results: The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Conclusion: Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  4. Obturator externus was larger, while obturator internus size was similar in ballet dancers compared to nondancing athletes.

    Science.gov (United States)

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Cook, Jill

    2018-06-02

    To compare the cross-sectional area (CSA) of hip external rotators, obturator externus (OE) and obturator internus (OI), in ballet dancers and nondancing athletes, and evaluate the relationship between obturator muscle size and hip pain. Case-control study. Elite ballet and sport. 33 male and female professional ballet dancers and 33 age and sex-matched athletes. CSA's of OE and OI measured on magnetic resonance imaging (MRI) of one hip. Hip pain was scored with the Copenhagen Hip and Groin Outcome Score (HAGOS): HAGOS pain score of 100 was defined as no pain and a score less than 100 was defined as pain. Participants weight and height. Estimated marginal mean CSA of OE was 14% larger in dancers than athletes (p = 0.01, ηp2 = 0.1); the size of OI was similar (p > 0.05). Men and women in both groups had similar sized OI and OE. There was no interaction between the estimated marginal mean CSA of either obturator and hip pain. It appears that ballet selectively increases muscle size of OE, but not OI. Obturator size was not related to mild hip pain, as OE and OI size was similar in dancers and athletes with and without pain. Copyright © 2018. Published by Elsevier Ltd.

  5. Two-Tunnel Transtibial Repair of Radial Meniscus Tears Produces Comparable Results to Inside-Out Repair of Vertical Meniscus Tears.

    Science.gov (United States)

    Cinque, Mark E; Geeslin, Andrew G; Chahla, Jorge; Dornan, Grant J; LaPrade, Robert F

    2017-08-01

    Radial meniscus tears disrupt the circumferential fibers and thereby compromise meniscus integrity. Historically, radial tears were often treated with meniscectomy because of an incomplete understanding of the biomechanical consequences of these tears, limited information regarding the biomechanical performance of repair, and the technical difficulty associated with repair. There is a paucity of studies on the outcomes of the repair of radial meniscus tears. Purpose/Hypothesis: The purpose was to determine the outcomes of 2-tunnel transtibial repair of radial meniscus tears and compare these results to the outcomes of patients who underwent the repair of vertical meniscus tears with a minimum of 2-year follow-up. The hypothesis was that radial and vertical meniscus tear repair outcomes were comparable. Cohort study; Level of evidence, 3. Patients who underwent 2-tunnel transtibial pullout repair for a radial meniscus tear were included in this study and compared with patients who underwent inside-out repair for a vertical meniscus tear. Subjective questionnaires were administered preoperatively and at a minimum of 2-year follow-up, including the Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Short Form-12 (SF-12) physical component summary (PCS), the Tegner activity scale, and patient satisfaction. Analysis of covariance was used to compare postoperative outcome scores between the meniscus repair groups while accounting for baseline scores. Adjusted mean effects relative to the radial repair group were reported with 95% CIs. Twenty-seven patients who underwent 2-tunnel transtibial pullout repair for radial meniscus tears and 33 patients who underwent inside-out repair for vertical meniscus tears were available for follow-up at a mean of 3.5 years (range, 2.0-5.4 years). No preoperative outcome score significantly differed between the groups. There were no significant group differences for any of the 2-year

  6. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  7. Obturator nerve schwannoma presenting as an adnexal mass: case report

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, M.; Thurston, W.A.; Merchant, N. [The Toronto Hospital, Dept. of Medical Imaging, Toronto, Ontario (Canada); Murphy, K.J. [The Toronto Hospital, Dept. of Obstetrics and Gynecology, Toronto, Ontario (Canada)

    1999-02-01

    Schwannomas are relatively common, benign nerve-sheath tumours. They arise most commonly from either cranial nerves or the dorsal root of spinal nerves. Schwannomas have also been reported to occur in peripheral nerve-root trunks, although this location is much less common. We report a case of a 45-year-old woman with a large pelvic mass originally believed to be an ovarian tumour. Following surgical excision, the tumour was found to be a schwannoma of the obturator nerve. To our knowledge, there are no reported cases of an obturator nerve schwannoma. The imaging features of schwannomas are reviewed. (author)

  8. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    Science.gov (United States)

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  9. Contact area between femoral tunnel and interference screw in anatomic rectangular tunnel ACL reconstruction: a comparison of outside-in and trans-portal inside-out techniques.

    Science.gov (United States)

    Hiramatsu, Kunihiko; Mae, Tatsuo; Tachibana, Yuta; Nakagawa, Shigeto; Shino, Konsei

    2018-02-01

    The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3-5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel (P contact ratio than the TP technique after ART ACLR. Retrospective comparative study, Level III.

  10. Mothering From the Inside Out: Results of a second randomized clinical trial testing a mentalization-based intervention for mothers in addiction treatment.

    Science.gov (United States)

    Suchman, Nancy E; DeCoste, Cindy L; McMahon, Thomas J; Dalton, Rachel; Mayes, Linda C; Borelli, Jessica

    2017-05-01

    Mothers with histories of alcohol and drug addiction have shown greater difficulty parenting young children than mothers with no history of substance misuse. This study was the second randomized clinical trial testing the efficacy of Mothering From the Inside Out (MIO), a 12-week mentalization-based individual therapy designed to address psychological deficits commonly associated with chronic substance use that also interfere with the capacity to parent young children. Eighty-seven mothers caring for a child between 11 and 60 months of age were randomly assigned to receive 12 sessions of MIO versus 12 sessions of parent education (PE), a psychoeducation active control comparison. Maternal reflective functioning, representations of caregiving, mother-child interaction quality, and child attachment were evaluated at baseline and posttreatment and 3-month follow-up. Mother-child interaction quality was assessed again at 12-month follow-up. In comparison with PE mothers, MIO mothers demonstrated a higher capacity for reflective functioning and representational coherence at posttreatment and 3-month follow-up. At 12-month follow-up, compared to PE cohorts, MIO mothers demonstrated greater sensitivity, their children showed greater involvement, and MIO dyads showed greater reciprocity. As addiction severity increased, MIO also appeared to serve as a protective factor for maternal reflective functioning, quality of mother-child interactions, and child attachment status. Results demonstrate the promise of mentalization-based interventions provided concomitant with addiction treatment for mothers and their young children.

  11. Mothering from the Inside Out: Results of a second randomized clinical trial testing a mentalization-based intervention for mothers in addiction treatment

    Science.gov (United States)

    Suchman, Nancy E.; DeCoste, Cindy L.; McMahon, Thomas J.; Dalton, Rachel; Mayes, Linda C.; Borelli, Jessica

    2016-01-01

    Mothers with histories of alcohol and drug addiction have shown greater difficulty parenting young children than mothers with no history of substance misuse. This study was the second randomized clinical trial testing the efficacy of Mothering from the Inside Out (MIO), a 12-week mentalization-based individual therapy designed to address psychological deficits commonly associated with chronic substance use that also interfere with the capacity to parent young children. Eighty-seven mothers caring for a child between 11 and 60 months of age were randomly assigned to receive 12 sessions of MIO versus 12 sessions of Parent Education (PE)—a psychoeducation active control comparison. Maternal reflective functioning, representations of caregiving, mother-child interaction quality, and child attachment were evaluated at baseline and post-treatment and 3-month follow up. Mother-child interaction quality was assessed again at 12-month follow up. In comparison with PE mothers, MIO mothers demonstrated a higher capacity for reflective functioning and representational coherence at post-treatment and 3-month follow up. At 12-month follow up, compared to PE cohorts, MIO mothers demonstrated greater sensitivity, their children showed greater involvement, and MIO dyads showed greater reciprocity. As addiction severity increased, MIO also appeared to serve as a protective factor for maternal reflective functioning, quality of mother-child interactions, and child attachment status. Results demonstrate the promise of mentalization-based interventions provided concomitant with addiction treatment for mothers and their young children. PMID:28401850

  12. A conservative method of retaining an interim obturator for a total maxillectomy patient

    Directory of Open Access Journals (Sweden)

    Nirmal Famila Bettie

    2017-01-01

    Full Text Available Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  13. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient.

    Science.gov (United States)

    Bettie, Nirmal Famila

    2017-11-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  14. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  15. Oral function after maxillectomy and reconstruction with an obturator.

    Science.gov (United States)

    Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M

    2012-11-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Obturator prostheses in post-oncological maxillofacial patients: our experience

    Directory of Open Access Journals (Sweden)

    Edoardo Brauner

    2014-12-01

    Full Text Available Background: Surgical procedures for tumors of the paranasal sinus, palatal epithelium, minor salivary glands or osteosarcoma of the upper jaw require a partial or total maxillectomy of the upper jaw. When the surgical procedure and/or radiation therapy result in a communication, the solution is necessarily prosthetical, through a palatal obturator that recreates a partition between the oral and nasal cavities. Methods: Authors selected 32 post-oncological patients with the upper maxilla completely edentulous prosthetically rehabilitated with a palatal obturator. Results: No serious complications or adverse reactions were reported during the fabrication of surgical or definitive obturators. All patients stated to benefit the palatal obturator in terms of quality of life. Conclusion: Prosthetic rehabilitation of edentulous maxillectomy with oral communication is a demanding challenge for the prosthodontist. The goals of prosthetic rehabilitation include separation of oral and nasal cavities to allow adequate deglutition and articulation of teeth, restore midfacial soft tissue contour and a satisfactory esthetic outcome. When, for any reason, the patient is not a suitable candidate for an implant-retained overdenture, a total removable prosthesis should ensure the most comfort in terms of swallowing, phonation and aesthetics.

  17. Bowel obstruction in obturator hernia: A challenging diagnosis

    Directory of Open Access Journals (Sweden)

    L. Conti

    2018-01-01

    Conclusion: Obturator hernia is a rare type of hernia due to his diagnosis, which is often unclear; a prompt suspect based for the non-specific symptoms is crucial for the diagnosis. Surgical management depends on early diagnosis and it is the only possible treatment for this pathology.

  18. Obturator Hernia: diagnosis and management under conditions of ...

    African Journals Online (AJOL)

    85.7%) underwent full resection and anastomosis, and one (14.3%) had partial resection. Hernia defect was closed in four (57.1%). Wound infection was common (71.4%) and three (43%) died. Conclusion: Obturator hernia is mainly a disease ...

  19. Stress analysis in oral obturator prostheses: imaging photoelastic

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  20. Fabrication of Closed Hollow Bulb Obturator Using Thermoplastic Resin Material

    Directory of Open Access Journals (Sweden)

    Bidhan Shrestha

    2015-01-01

    Full Text Available Purpose. Closed hollow bulb obturators are used for the rehabilitation of postmaxillectomy patients. However, the time consuming process, complexity of fabrication, water leakage, and discoloration are notable disadvantages of this technique. This paper describes a clinical report of fabricating closed hollow bulb obturator using a single flask and one time processing method for an acquired maxillary defect. Hard thermoplastic resin sheet has been used for the fabrication of hollow bulb part of the obturator. Method. After fabrication of master cast conventionally, bulb and lid part of the defect were formed separately and joined by autopolymerizing acrylic resin to form one sized smaller hollow body. During packing procedure, the defect area was loaded with heat polymerizing acrylic resin and then previously fabricated smaller hollow body was adapted over it. The whole area was then loaded with heat cure acrylic. Further processes were carried out conventionally. Conclusion. This technique uses single flask which reduces laboratory time and makes the procedure simple. The thickness of hollow bulb can be controlled and light weight closed hollow bulb prosthesis can be fabricated. It also minimizes the disadvantages of closed hollow bulb obturator such as water leakage, bacterial infection, and discoloration.

  1. Effect of phosphatidylinositol and inside-out erythrocyte vesicles on autolysis of mu- and m-calpain from bovine skeletal muscle.

    Science.gov (United States)

    Zalewska, Teresa; Thompson, Valery F; Goll, Darrel E

    2004-08-23

    The finding that phospholipid micelles lowered the Ca2+ concentration required for autolysis of the calpains led to a hypothesis suggesting that the calpains are translocated to the plasma membrane where they interact with phospholipids to initiate their autolysis. However, the effect of plasma membranes themselves on the Ca2+ concentration required for calpain autolysis has never been reported. Also, if interaction with a membrane lowers the Ca2+ required for autolysis, the membrane-bound-calpain must autolyze itself, because it would be the only calpain having the reduced Ca2+ requirement. This implies that the autolysis is an intramolecular process, although several studies have shown that autolysis of the calpains in an in vitro assay and in the absence of phospholipid is an intermolecular process. Inside-out vesicles prepared from erythrocytes had no effect on the Ca2+ concentration required for autolysis of either mu- or m-calpain, although phosphatidylinositol (PI) decreased the Ca2+ concentration required for autolysis of the same calpains. The presence of a substrate for the calpains, beta-casein, reduced the rate of autolysis of both mu- and m-calpain both in the presence and in the absence of PI, suggesting that mu- and m-calpain autolysis is an intermolecular process in the presence of PI just as it is in its absence. Because IOV have no effect on the Ca2+ concentration required for calpain autolysis, association with the plasma membrane, at least with erythrocyte plasma membranes, does not initiate calpain autolysis by reducing the Ca2+ concentration required for autolysis as suggested by the membrane-activation hypothesis. Interaction with a membrane may serve to bind calpains to their substrates rather than promoting autolysis.

  2. DUST PROPERTIES AND DISK STRUCTURE OF EVOLVED PROTOPLANETARY DISKS IN Cep OB2: GRAIN GROWTH, SETTLING, GAS AND DUST MASS, AND INSIDE-OUT EVOLUTION

    International Nuclear Information System (INIS)

    Sicilia-Aguilar, Aurora; Henning, Thomas; Dullemond, Cornelis P.; Bouwman, Jeroen; Sturm, Bernhard; Patel, Nimesh; Juhász, Attila

    2011-01-01

    We present Spitzer/Infrared Spectrograph spectra of 31 T Tauri stars (TTS) and IRAM/1.3 mm observations for 34 low- and intermediate-mass stars in the Cep OB2 region. Including our previously published data, we analyze 56 TTS and 3 intermediate-mass stars with silicate features in Tr 37 (∼4 Myr) and NGC 7160 (∼12 Myr). The silicate emission features are well reproduced with a mixture of amorphous (with olivine, forsterite, and silica stoichiometry) and crystalline grains (forsterite, enstatite). We explore grain size and disk structure using radiative transfer disk models, finding that most objects have suffered substantial evolution (grain growth, settling). About half of the disks show inside-out evolution, with either dust-cleared inner holes or a radially dependent dust distribution, typically with larger grains and more settling in the innermost disk. The typical strong silicate features nevertheless require the presence of small dust grains, and could be explained by differential settling according to grain size, anomalous dust distributions, and/or optically thin dust populations within disk gaps. M-type stars tend to have weaker silicate emission and steeper spectral energy distributions than K-type objects. The inferred low dust masses are in a strong contrast with the relatively high gas accretion rates, suggesting global grain growth and/or an anomalous gas-to-dust ratio. Transition disks in the Cep OB2 region display strongly processed grains, suggesting that they are dominated by dust evolution and settling. Finally, the presence of rare but remarkable disks with strong accretion at old ages reveals that some very massive disks may still survive to grain growth, gravitational instabilities, and planet formation.

  3. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful...

  5. Safety brake for tape reels

    Science.gov (United States)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  6. Comparing low volume saphenous-obturator block with placebo and femoral-obturator block for anterior cruciate ligament reconstruction: a randomized controlled trial

    DEFF Research Database (Denmark)

    Lenz, Katja; Jensen, Kenneth; Tanggaard, Katrine

    2018-01-01

    BACKGROUND: Anterior cruciate ligament reconstruction (ACL-RC) is often associated with moderate to severe postoperative pain even with a multimodal analgesic regimen. We aimed to compare the analgesic efficacy of low volume saphenous-obturator block with placebo and femoral- obturator block in p...

  7. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  8. Rehabilitation of Posterior Maxilla with Obturator Supported by Zygomatic Implants

    Directory of Open Access Journals (Sweden)

    Sankalp Mittal

    2018-01-01

    Full Text Available Prosthetic rehabilitation of atrophic maxilla and large maxillary defects can be done successfully by zygomatic implant-supported prosthesis. Zygomatic implants are an avant-garde to complex and invasive-free vascularised osteocutaneous flaps, distraction osteogenesis, and the solution to flap failures. A treated case of tuberculous osteomyelitis, with a class II (Aramany’s classification maxillary defect, reported to oral maxillofacial department, Government Dental College (RUHS-CODS. The defect in this group was unilateral, retaining the anterior teeth. The patient was previously rehabilitated with a removable maxillary obturator. Inadequate retention affected essential functions like speaking, mastication, swallowing, esthetics, and so on due to lack of sufficient supporting tissues. A fixed prosthetic rehabilitation of posterior maxillary defect was done with obturator supported with two single-piece zygomatic implants. At 1-year follow-up, the patient was comfortable with the prosthesis, and no further complaints were recorded.

  9. Management of maxillectomy defect with a hybrid hollow bulb obturator

    Science.gov (United States)

    Singh, Kamleshwar; Singh, Saumyendra V; Mishra, Niraj; Agrawal, Kaushal Kishor

    2013-01-01

    A woman having already undergone maxillectomy came to the department complaining of difficulty in eating and speech. During the construction of an obturator, the bulb area should be hollowed to reduce weight so that the teeth and supporting tissues are not stressed unnecessarily. The conventional open design drains fluid from the adjacent mucosa, possibly increasing the weight of the prosthesis, and is difficult to clean. The closed bulb design does not drain secretions and may cause obstruction and susceptibility to infection in the paranasal and pharyngeal regions, though it is easier to maintain. An alternative to the two designs, combining their advantages, is presented in this report. As the open hollow part of the obturator was shallow, it was easy to clean. Making the inferior part of the bulb hollow and closed led to a reduction in the overall weight of the prosthesis while increasing its resonance. PMID:23436886

  10. [Clinical-diagnostic estimation of carbohydrates metabolism in obturation jaundice].

    Science.gov (United States)

    Nychytaĭlo, M Iu; Malyk, S V

    2004-07-01

    Complex examination of 175 patients with obturation jaundice was conducted, peculiar attention was spared to the carbohydrates metabolism changes, characterizing hepatic state. It was established, that in obturation jaundice in the liver there are occurring inflammatory changes and disturbances of all kinds of metabolism, including that of carbohydrates, severity of which depends on duration of jaundice, the concurrent diseases presence, they shows lowering of the glucose and glycogen level in the blood, as well as the hepatic glycogen content, that's why they may be applied as a complex of prognostic criterions for the disease course. An early conduction of operative treatment, elimination of the biliary ducts impassability promote the rehabilitation period shortening and the hepatic functional activity normalization.

  11. Enhanced retention of a maxillofacial prosthetic obturator using precision attachments: Two case reports

    OpenAIRE

    Murat, Sema; Gurbuz, Ayhan; Isayev, Abulfaz; Dokmez, Bahadir; Cetin, Unsun

    2012-01-01

    The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator’s aesthetic advantages. This clinical report describes the prosthetic rehabil...

  12. Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report

    Science.gov (United States)

    Hou, Yue-Zhong; Huang, Zhi; Ye, Hong-Qiang; Zhou, Yong-Sheng

    2012-01-01

    The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory, pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator. PMID:22653550

  13. Obturator Neuromodulation with Laparoscopic Placement of an Obturator Lead for the Treatment of Intractable Opioid Dependent Chronic Pelvic Pain due to Obturator Neuralgia.

    Science.gov (United States)

    Marvel, Richard P

    2018-05-12

    Chronic pelvic pain(CPP) is a common condition in women that can have a devastating effect on quality of life. Some of the most severe forms of CPP are related to peripheral nerve injuries causing persistent neuropathic pain. This is a case of a young woman with severe opioid dependent chronic pelvic and right groin pain due to obturator neuralgia. She had failed a multitude of treatments including multiple medications, manual physical therapy, nerve blocks, surgical neurolysis and spinal cord stimulation without significant benefit. She underwent a trial of peripheral neuromodulation of the obturator nerve with laparoscopic placement of a quadripolar lead. During the 6-day trial she had almost complete relief of her pain; therefore, she underwent permanent implantation of an intermittent pulse generator. Over the next 6 months she was completely weaned completely off her chronic opioids. At 23 months post implantation, she had essentially no pain and is no longer on any analgesic, antidepressant or membrane stabilizing medications. Peripheral Neuromodulation has the potential to alleviate pain and significantly improve quality of life in women with longstanding neuropathic chronic pelvic pain who have failed multimodal conservative therapy. Copyright © 2018. Published by Elsevier Inc.

  14. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  15. Application for the Tape Station

    CERN Document Server

    Solero, A

    2003-01-01

    The Tape Station is used as an Isolde facility to observe the variations of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be controlled the Tape station program. During the Isolde consolidation project, the Tape Station has been rebuilt, and the control system has been fully integrated in the PS control. Finally, a new application has been written in JAVA Development kit 1.4 and the PS Java environment. The main purpose of this note is to explain how to use this program.

  16. Root canal obturation of primary teeth: Disposable injection technique

    Directory of Open Access Journals (Sweden)

    S K Bhandari

    2012-01-01

    Full Text Available The aim of the study was to outline a simple, cost-effective technique for obturation of primary tooth root canals. A total of 75 primary teeth were treated in 52 subjects by the technique discussed, i.e. injecting plastic flowable material into the root canals after desired preparation, using disposable needle and syringe. All the patients were followed up for 3 years and 6 months, with no clinical or radiologic evidence of pathology or need for untimely extraction. In conclusion, the technique described is simple, economical, can be used with almost all filling materials used for the purpose, and is easy to master with minimal chances of failure.

  17. Strangulated obturator hernia - an unusual presentation of intestinal obstruction.

    LENUS (Irish Health Repository)

    Zeeshan, Saqib

    2012-01-31

    An 81-year-old Caucasian emaciated female presented with 3 days history of colicky abdominal pain nausea, projectile vomiting and abdominal distension. A pre-operative diagnosis of mechanical bowel obstruction was made. The absence of characteristic clinical signs in this thin elderly woman with a small bowel obstruction failed to provide a pre-operative diagnosis. She underwent a midline laparotomy and resection and anastomosis of small bowel and repair of the strangulated right obturator hernia. The high mortality rate associated with this type of abdominal hernias requires a high index of suspicion to facilitate rapid diagnosis and prompt surgical intervention if the survival rate is to be improved.

  18. Rehabilitation of large maxillary defect with two-piece maxillary obturators

    Directory of Open Access Journals (Sweden)

    Kanchan P Dholam

    2015-01-01

    Full Text Available The insertion and removal of an obturator in large maxillary defects with or without trismus is difficult. Fabrication of a two-piece obturator in such cases overcomes this problem. This article describes rehabilitation of large maxillary defects with two piece maxillary obturator of three types. All these obturators have a maxillary plate and a bulb component, which are approximated together by various techniques namely, silicone cover, embedded magnets, and press studs. Prosthetic rehabilitation of large maxillary defects with two-piece obturators offers the possibility of adequate oral rehabilitation by fabricating light weight prosthesis, which is easy to use. The bulb covers the undercut areas of the defect enhancing the facial contour and retention. It facilitates easy examination of underlying tissues, recreation of the anatomic barrier between the oral and nasal cavities and restoration of the function and esthetics. Thus, it adds to the quality of life.

  19. Obturator hernia should be considered in the differential diagnosis of hip and knee pain.

    Science.gov (United States)

    Belli, Ahmet Korkut; Memiş, Gündüz; Dere, Özcan; Koşan, Ulaş; Nazlı, Okay

    2016-11-01

    Obturator hernia is a rare disease usually occurring in debilitated elderly women. Pain radiating down the medial thigh and knee (Howship-Romberg sign) is a specific sign of the disease. Presently described is a case of obturator hernia in a 73-year-old female patient who presented with severe left hip pain radiating down the medial thigh and knee, nausea, and loss of appetite. Initially, vertebral disc herniation was thought to be cause, but abdomino-pelvic computed tomography scan revealed left strangulated obturator hernia. Diagnosis of obturator hernia can be challenging. Physicians should consider obturator hernia in the differential diagnosis of knee and hip pain, and investigate for Howship-Romberg sign. Early diagnosis of the disease not only decreases morbidity and mortality, but also presents opportunity to treat with minimally invasive methods.

  20. Brief reports: ultrasound-guided obturator nerve block: a proximal interfascial technique.

    Science.gov (United States)

    Taha, Ahmad Muhammad

    2012-01-01

    In this report, I describe and evaluate a proximal ultrasound (US)-guided obturator nerve block technique using an interfascial local anesthetic (LA) injection deep to the pectineus muscle. The pectineus muscle was identified and followed, while the US probe was tilted cranially until the superior pubic ramus was visualized. In this plane, LA was injected interfascially between the pectineus and obturator externus. The median time required to identify the injection site was 4 seconds (95% confidence interval, 3-5 seconds). The median motor block onset was 4 minutes (95% confidence interval, 3-5 minutes). Both obturator nerve branches were blocked successfully in all patients (100%). The US-guided obturator nerve block using interfascial LA injection inferior to the superior pubic ramus, between the pectineus and obturator externus muscles, was shown to be a simple and successful technique.

  1. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  2. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  3. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

    Science.gov (United States)

    Faus-Llácer, Vicente; Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-04-01

    The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.

  4. The influence of obturators on the respiration of patients with maxillary defects: a clinical study.

    Directory of Open Access Journals (Sweden)

    Xian Dong

    Full Text Available The study evaluated the effects of obturators on respiratory function by analyzing the changes in nasal anatomic structures and physiologic function in maxillectomy patients with and without obturators. Twenty-six patients who underwent maxillectomy were chosen and rehabilitated with obturators by a single maxillofacial prosthodontist. The geometric shape of the nasal cavity, the nasal airway resistance, and the ratio of residual volume to total lung capacity (RV/TLC were evaluated using acoustic rhinometry, rhinomanometry, and a pulmonary function test apparatus, respectively. All patients were tested twice, with and without their obturators. The results were statistically analyzed with a paired t-test. The nasal cavities (0-7 cm to the anterior nostril of the patients with obturators had a significantly smaller volume ([-8.92, -0.60], P = 0.027, smaller effective nasal cross-sectional area MCA2 ([-3.80, -1,81], P < 0.0001, increased airflow in the nasal cavity ([17.76, 147.39], P = 0.015, reduced nasal airway resistance ([-0.11, -0.02], P = 0.009, and reduced RV/TLC ([-5.32, -1.30], P = 0.004 compared with the patients without obturators. According to the results of this study, obturators can improve respiratory function by effectively decreasing the volume of enlarged nasal cavities as well as the nasal air resistance and volume of anatomical dead space after maxillectomy.

  5. Asteroid Composite Tape

    Science.gov (United States)

    1998-07-01

    This is a composite tape showing 10 short segments primarily about asteroids. The segments have short introductory slides, which include brief descriptions about the shots. The segments are: (1) Radar movie of asteroid 1620 Geographos; (2) Animation of the trajectories of Toutatis and Earth (3) Animation of a landing on Toutatis; (4) Simulated encounter of an asteroid with Earth, includes a simulated impact trajectory; (5) An animated overview of the Manrover vehicle; (6) The Near Earth Asteroid Tracking project, includes a photograph of USAF Station in Hawaii, and animation of Earth approaching 4179 Toutatis and the asteroid Gaspara; (7) live video of the anchor tests of the Champoleon anchoring apparatus; (8) a second live video of the Champoleon anchor tests showing anchoring spikes, and collision rings; (9) An animated segment with narration about the Stardust mission with sound, which describes the mission to fly close to a comet, and capture cometary material for return to Earth; (10) live video of the drop test of a Stardust replica from a hot air balloon; this includes sound but is not narrated.

  6. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study

    OpenAIRE

    Hiremath, Mallayya C.; Srivastava, Pooja

    2016-01-01

    Purpose: The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. Materials and Methods: A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presenc...

  7. Obturator yang Berfungsi Sebagai Protesa pada Perawatan Pasien Sumbing Langitan (Laporan Kasus

    Directory of Open Access Journals (Sweden)

    Avy Permata Sari

    2015-11-01

    Full Text Available Palatal cleft is opening of palatal including palatum mole and durum. It is caused by growth and development disturbance intra uterine. There are some etiology lke genetic factor, infection, drugs, mutagenic material, malnutrition, and psychological problem during pregnancy. In this case the patient came to our clinic to be made obturator to close the palatal fistule that caused speech and nutrition problems. Because there were some missing teeth, the obturator was combined with prosthetic design. At recall visit the obturator improved speech, swallow, and mastication functions and aesthetics and patient showed the ability to use it by himself.

  8. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  9. Tape casting fluorinated YBC123

    International Nuclear Information System (INIS)

    Taylor, J.A.T.; Luke, D.M.; Whiteley, B.A.

    1991-01-01

    Tape casting the superconducting Ba-Y-Cu oxide was accomplished by several laboratories and show promise for being a versatile forming technique. The major problem is low current density, probably due to lack of grain alignment and grain boundary related weak links. The latter problem may be due to formation of carbonates and hydroxides during binder burnout. Preliminary work done at Alfred shows that a bimodal powder size distribution displays significant alignment after tape casting and that F treated powder is resistant to attack by steam at 100C. Such corrosion resistant powder cast as form tape should survive the binder burnout without the detrimental grain boundary phases that develop from reaction of the superconducting phase, steam and carbon dioxide. This paper presents the results of an investigation of tape casting fluorinated powder with a bimodal size distribution

  10. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  11. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  12. Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis

    OpenAIRE

    Wei Huang; Tao Wang; Huantao Zong; Yong Zhang

    2015-01-01

    Purpose: To assess the efficacy and safety of tension-free vaginal tape (TVT)-Secur for stress urinary incontinence (SUI). Methods: A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register. Results: Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O) and TVT. We found that TVT-Secur had s...

  13. History of psychology turned inside out

    NARCIS (Netherlands)

    van Rappard, J.F.H.

    1997-01-01

    Danziger (1994) distinguished between the insider-scientist and the outsider-historian models for the history of psychology. The present paper contends that since in psychology history has a contemporary relevance, there is a place for insider history in the discipline; hence, a mixed model is

  14. Microsoft Office Excel 2003 Inside Out

    CERN Document Server

    Stinson, Craig

    2003-01-01

    Hey, you know your way around a spreadsheet-so now dig into Excel 2003 and really put your data to work! This supremely organized reference packs hundreds of timesaving solutions, troubleshooting tips, and handy workarounds in concise, fast-answer format. It's all muscle and no fluff. Discover the best and fastest ways to perform everyday tasks, and challenge yourself to new levels of Excel mastery! Build on what you already know about Excel and quickly dive into what's newLearn how the experts design more powerful spreadsheetsSharpen your core to advanced document editing and formatting skil

  15. Sympathy for the devil: communication inside out

    International Nuclear Information System (INIS)

    Meskens, G.

    2000-01-01

    Modem time prides itself on it's strict rational reasoning: helped by modem science and philosophy, this has led to the creation of our intelligent society. The more mankind performs cutting-edge research and generates innovative scientific applications, and the inevitable way these impacts on nature influence our daily life, the more we seem to have to cope with new kinds of problems and questions. On top of that, it is obvious that not everyone feels as comfortable with all the possible solutions that are evolving. Based on rationalism, one can present simple solutions for issues such as global warming, the apparent uncontrollable population growth, the disposal of radioactive waste and the concerns regarding the possible applications of genetic manipulation. However, it is clear that the one and only pure rational solution to those kind of problems doesn't exist, because people are simply not able to keep values related to their persona/ sphere out of reasonings which should lead to a solution in function of the common interest, and this is not always a bad thing ... (author)

  16. Inside-Out Manufacturing of Composite Structures

    Data.gov (United States)

    National Aeronautics and Space Administration — Tooling for the manufacture of large structures from composite materials often costs much more than individual parts, rendering the processes unattractive for...

  17. Information and Communication Technology Inside Out

    DEFF Research Database (Denmark)

    Riis, Søren

    2017-01-01

    Information and communication technology (ICT) has become the great technological fix of our time and not the least in the education system. There seems to be no end to the hype of ICT and the accompanying promises that education will be revolutionized—“smart” pupils will be made and the so...

  18. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    Science.gov (United States)

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  19. REHABILITATION OF A HEMI-MAXILLECTOMY PATIENT WITH A CAST PARTIAL OBTURATOR PROSTHESIS - A CLINICAL REPORT.

    OpenAIRE

    Aprajita; Atul Bhatnagar; Kumari Deepika; Shankar singh.

    2018-01-01

    Prosthodontic rehabilitation of patient who have underwent maxillectomy surgery is a challenging task. Achieving optimum stability, retention and support are the major problems. An obturator with cast partial design is used to rehabilitate maxillectomy defect. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissues and to provide comfort, function, and aesthetics to the patients. This case report describes several steps of fabrication of a definitive obtu...

  20. [MORPHOLOGICAL CHANGES OF THE LIVER IN OBTURATION JAUNDICE, CAUSED BY CHOLEDOCHOLITHIASIS, DEPENDING ON ITS DURATION].

    Science.gov (United States)

    Sipliviy, V A; Yevtushenko, D V; Naumova, O V; Andreyeshchev, S A; Yevtushenko, A V

    2016-02-01

    Abstract The results of surgical treatment of 184 patients for obturation jaundice, caused by choledocholithiasis, were analyzed. Morphological changes of the liver were studied in 20 patients. There were three groups of patients delineated, depending on the obturation jaundice duration: up to 7 days, from 8 to 14 days, more than 15 days, and also a group of patients after the bile outflow restoration. The obturation jaundice occurrence in choledocholithiasis is accompanied by significant morphological changes in the liver, severity of which is enhancing while the obturation jaundice persistence increasing. While persistence of obturation jaundice through 8 days and more the connective tissue volume is enhancing, a relative volume of hepatocytes is reducing and a stromal-parenchymatous index is increasing. The bile outflow restoration secures significant reduction of intensity of alterative and inflammatory changes in hepatic parenchyma, as well as activation of reparative processes in the tissue. In cholangitis, caused by P. aeruginosa and E. coli, according to morphological investigations data, in the liver a diffuse purulent cholangitis on background of chronic changes in accordance to duration of the obturation jaundice persists.

  1. Successful Treatment of Gluteal Pain from Obturator Internus Tendinitis and Bursitis with Ultrasound-Guided Injection.

    Science.gov (United States)

    Chen, Boqing; Rispoli, Leia; Stitik, Todd; Leong, Michelle

    2017-10-01

    This case report describes what the authors believe is the first case of a patient with obturator internus tendinitis and bursitis successfully treated with a corticosteroid injection using a trans-tendinous lateral to medial approach. The patient presented with right gluteal pain not relieved by physical therapy or right hip and ischial bursa corticosteroid injections. Pelvic and lumbar spine MRIs and EMG/NCS findings were unremarkable. Physical examination demonstrated tenderness to palpation at the right middle lower gluteal region. Ultrasound imaging with sonopalpation identified the maximal local tender point as the right obturator internus muscle and/or its underlying bursa. A 22-gauge 3.5-inch needle was inserted in-plane to the transducer and longitudinal to the obturator internus from a lateral to medial direction, an approach previously described in cadavers. The obturator internus tendon sheath and bursa were injected with 2.5 ml of 0.5% lidocaine combined with 10 mg of triamcinolone. The patient reported immediate complete relief of pain with continued relief at 2 and 6 months post-injection. This case report demonstrates an injection of the obturator internus tendon sheath and bursa using a trans-tendinous approach, which may be successful for treatment of patients presenting with persistent gluteal pain from obturator internus tendinitis and bursitis.

  2. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  3. Tape write-efficiency improvements in CASTOR

    International Nuclear Information System (INIS)

    Murray, S; Bahyl, V; Cancio, G; Cano, E; Lo Presti, G; Lo Re, G; Ponce, S; Kotlyar, V

    2012-01-01

    The CERN Advanced STORage manager (CASTOR) is used to archive to tape the physics data of past and present physics experiments. For reasons of physical storage space, all of the tape resident data in CASTOR are repacked onto higher density tapes approximately every two years. Improving the performance of writing files smaller than 2GB to tape is essential in order to keep the time needed to repack all of the tape resident data within a period of no more than 1 year. This paper reports on the solution to writing efficiently to tape that is currently in its early deployment phases at CERN.

  4. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  5. The TVT-obturator surgical procedure for the treatment of female stress urinary incontinence: a clinical update.

    Science.gov (United States)

    Waltregny, David; de Leval, Jean

    2009-03-01

    Six years ago, the inside-out transobturator tape TVT-O procedure was developed for the surgical treatment of female stress urinary incontinence (SUI) with the aim of minimizing the risk of urethra and bladder injuries and ensuring minimal tissue dissection. Initial feasibility and efficacy studies suggested that the TVT-O procedure is associated with high SUI cure rates and low morbidity at short term. A recent analysis of medium-term results indicated that the TVT-O procedure is efficient, with maintenance, after a 3-year minimum follow-up, of cure rates comparing favorably with those reported for TVT. No late complications were observed. As of July 2008, more than 35 clinical papers, including ten randomized trials and two national registries, have been published on the outcome of the TVT-O surgery. Results from these studies have confirmed that the TVT-O procedure is safe and as efficient as the TVT procedure, at least in the short/medium term.

  6. Full Mouth Reconstruction of a Skeletal Class II Division 1 Patient with Adenoid Cystic Carcinoma Using an Interim Immediate Obturator and a Definitive Obturator

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available A 61-year-old female patient with adenoid cystic carcinoma (ACC of the right maxilla and Angle class II division 1 malocclusion had received a subtotal maxillectomy in right side and used a conventional clasp-retained obturator. After implants placement, a maxillary interim immediate obturator (IIO and then a definitive obturator using six endosseous implants were fabricated. During one-year follow-up, the patient was completely satisfied. Ideally, after implants placement in edentulous patients suffering from hemimaxillectomy, an implant-supported obturator (ISO is designed in order to prevent nasal reflux and to improve speech and swallowing. However, in the following case, because of skeletal class II division 1 malocclusion and implants insertion in the premaxilla, using an ISO was impossible because it would cause excessive upper lip protrusion and lack of anterior teeth contact. Therefore, a five-unit implant-supported fixed partial denture (FPD was fabricated in the maxillary anterior segment so that anterior teeth contacts were possible and the patient’s normal lip support was achieved. A bar and three ball attachments were used in the maxillary posterior segment. A closed-hollow-bulb ISO was preferred. Conventional ISO in these patients results in several problems. Using a maxillary anterior FPD along with ISO caused satisfactory results in the current patient.

  7. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  8. Transobturator vaginal tape in comparison to tension-free vaginal tape: A prospective trial with a minimum 12 months follow-up

    Directory of Open Access Journals (Sweden)

    R B Nerli

    2009-01-01

    Full Text Available Background: The tension-free vaginal tape (TVT procedure is based on the integral theory that the midurethra has an important role in the continence mechanism. Transobturator vaginal tape (TOT is the same in concept as TVT but it differs from TVT in that, rather than passing through the retropubic space, sling materials are drawn through the obturator foramina. We prospectively compared TVT with TOT with respect to operation-related morbidity and surgical outcomes at a minimum follow up of 12 months. Materials and Methods: A total of 36 women with stress urinary incontinence (SUI were alternatively assigned to the TVT group (18 or the TOT group. Preoperative evaluation included urodynamic study and I-QOL questionnaire. One year after operation the surgical result, patient satisfaction, incontinence quality-of-life questionnaire, long-term complications, and uroflowmetry were evaluated in both groups. Results: The patient characteristics in both the TVT and TOT group were similar. Mean operating time was significantly shorter in the TOT group likened to the TVT group. Conclusions: Both the TVT and TOT procedures are minimally invasive and similar in operation-related morbidity. TOT appears to be as effective as TVT, and safer than TVT for the surgical treatment of SUI in women at 12 months follow-up.

  9. A comparative In vivo efficacy of three spiral techniques versus incremental technique in obturating primary teeth

    Directory of Open Access Journals (Sweden)

    Shalini Chandrasekhar

    2018-01-01

    Full Text Available Background: The aim of this study was to evaluate the efficiency of four different obturating techniques in filling the radicular space in primary teeth. Materials and Methods: This clinical trial was carried out on 34 healthy, cooperative children (5–9 years who had 63 carious primary teeth indicated for pulpectomy. They were divided into four groups, such that in each group, a total of 40 canals were allotted for obturation with respective technique. The root canals of selected primary teeth were filled with Endoflas obturating material using either bi-directional spiral (Group 1; incremental technique (Group 2, past inject (Group 3 or lentulo spiral (Group 4 according to the groups assigned. The effectiveness of the obturation techniques was assessed using postoperative radiographs. The assessment was made for a depth of fill in the canal, the presence of any voids using Modified Coll and Sadrian criteria. The obtained data were analyzed by using ANOVA test and unpaired t-test. Results: Bi-directional spiral and lentulo spiral were superior to other techniques in providing optimally filled canals (P< 0.05. The bi-directional spiral was superior to lentulo spiral in preventing overfill (P< 0.05. Conclusion: Based on the present study results, bi-directional spiral can be recommended as an alternate obturating technique in primary teeth.

  10. Aesthethic and masticatory rehabilitation on post mandibular resection with combination of hollow obturator and hybrid prosthesis

    Directory of Open Access Journals (Sweden)

    Arif Rachman

    2009-06-01

    Full Text Available Background: Replacing tooth lost caused by caries, periodontal disease, trauma and neoplasm including ameloblastoma which requires mandibular resection is important. Purpose: The aim of the study to rehabilitation of post mandibular resection with combination of hollow obturator and hybrid prosthesis. Case: A patient 25 years old, male, for having prosthesis to cover defect due to post right mandibular resection. Case Management: In this presented case, mandibular plate was applied due to spreading defect with losing almost a half body of mandible (class II modification 2 according to cantor and curtis classification. The design of therapy was mandibular obturator using hybrid prosthesis (removable partial denture metal frame and fixed splint crown with precision attachment with hollow obturator. The application was based on several advantages: good aesthetic performance, retention, stability, lighter weight and equal share of vertical load for teeth on non surgical site. The result of control I, II, III, showed that aesthetic performance, masticatory function, speech and swallowing were in good condition. Conclusion: The design of mandibular obturator using hybrid denture with hollow obturator could rehabilitate aesthetic performance, masticatory function, speech and swallowing for patient with post mandibular resection.

  11. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  12. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  13. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  14. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  15. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  16. Examination of Articulation in Patient Using Obturator by Means of Computer Planning

    Directory of Open Access Journals (Sweden)

    Somaieh Allahiary

    2013-02-01

    Full Text Available Background and Aims: Approximately 5% of cancers involve structures of oral cavity. Partial resection of maxilla (maxillectomy may be performed in these cases. Maxillectomy often results in significant functional disabilities such as inability in mastication, deglutition and speech with adverse impact on psychological statusand social life of patients. Obturator prosthesis is a prosthodontic treatment to separate nasal and oral cavities and restore the critical above mentioned functions. The assessment of speech is considered to examine speech function restored by the treatment. The purpose of this study was to evaluate the speech in patients with resected maxilla who have been treated by obturator prosthesis from a pool of related patients in the Prosthodotnics department ofdental faculty, Tehran University of Medical Sciences. The evaluation was performed with computer software using sentence intelligibility (SI test. Materials and Methods: This cross sectional study was conducted on 10 subjects (23-66 years referred to the Prosthodontics department of the faculty and received an obturator. After primary examination of the prosthesis,the patients completed SI test in an acoustic room under guidance of a speech therapist. The performed tests were analyzed by the speech therapist. In addition, the SI with and without the prosthesis was evaluate by lay audience. The statistical analyses were performed using Wilcoxon-signed rank test and Weighted Kappa. Results: Significant differences were found between SI tests with and without the obturators (P<0.001. Two of 10 patients showed problems in speech function using obturator. Conclusion: Within the limitations of the present study, obturators had significant effect on improvement of the speech outcomes of examined patients. Improvement of the quality of life could be predicted.

  17. Quality of Life in Patients After Maxillectomy and Placement of Prosthetic Obturator.

    Science.gov (United States)

    Chen, Cheng; Ren, Wen-Hao; Huang, Rui-Zhe; Gao, Ling; Hu, Zhi-Ping; Zhang, Lin-Mei; Li, Shao-Ming; Dong, Kai; Qi, Hong; Zhi, Ke-Qian

    2016-01-01

    The aim of this study was to assess quality of life (QoL) and obturator functioning in patients having undergone a maxillectomy as a tumor ablative resection and rehabilitation with a prosthetic obturator. The University of Washington Quality of Life scale version 4 (UW-QoLv4) and the Obturator Functioning Scale (OFS) were used to evaluate the self-reported QoL and obturator functioning. The effects of demographic and treatment variables on QoL were assessed using age, defect size, postoperative radiotherapy (RT), neck dissection, and dentition. The study included 16 men and 13 women with a mean age of 48.8 years. Of the 29 patients, 16 had a Brown Class 2a or smaller defect and 13 had a Brown Class 2b or larger defect. The mean OFS score (P = .004) and the physical (P = .001) and social-emotional function scores (P = .001) of the patients who received postoperative RT were significantly lower than those who did not receive postoperative RT. The subscales for swallowing (P = .008), saliva (P = .001), pain (P = .001), and shoulder function (P = .002) correlated strongly with postoperative RT on the UW-QoL. The subscales for pronunciation (P = .007) and saliva (P = .002) correlated significantly with RT on the OFS. The mean OFS scores were significantly lower for the patients with a Brown Class 2a or smaller defect than for Brown Class 2b or larger (P = .005). Postoperative RT was the strongest variable affecting QoL in patients with maxillectomy and prosthetic obturator reconstruction. The size of the defect slightly influenced the obturator function; however, it did not influence the overall QoL.

  18. Does improvement in maternal attachment representations predict greater maternal sensitivity, child attachment security and lower rates of relapse to substance use? A second test of Mothering from the Inside Out treatment mechanisms.

    Science.gov (United States)

    Suchman, Nancy E; DeCoste, Cindy; Borelli, Jessica L; McMahon, Thomas J

    2018-02-01

    In this study, we replicated a rigorous test of the proposed mechanisms of change associated with Mothering from the Inside out (MIO), an evidence-based parenting therapy that aims to enhance maternal reflective functioning and mental representations of caregiving in mothers enrolled in addiction treatment and caring for young children. First, using data from 84 mothers who enrolled in our second randomized controlled trial, we examined whether therapist fidelity to core MIO treatment components predicted improvement in maternal reflective functioning and mental representations of caregiving, even after taking fidelity to non-MIO components into account. Next, we examined whether improvement in directly targeted outcomes (e.g., maternal mentalizing and mental representations of caregiving) led to improvements in the indirectly targeted outcome of maternal caregiving sensitivity, even after controlling for other plausible competing mechanisms (e.g., improvement in maternal psychiatric distress and substance use). Third, we examined whether improvement in targeted parenting outcomes (e.g., maternal mentalizing, mental representations of caregiving and caregiving sensitivity) was associated in improvement in child attachment status, even after controlling for competing mechanisms (e.g., improvement in maternal psychiatric distress and substance use). Finally, we examined whether improvement in maternal mentalizing and caregiving representations was associated with a reduction in relapse to substance use. Support was found for the first three tests of mechanisms but not the fourth. Implications for future research and intervention development are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Prosthetic Rehabilitation by Palatal Hollow Bulb Obturator with Cast Metal Denture Base: A Case Report

    Directory of Open Access Journals (Sweden)

    George Francis

    2015-01-01

    Full Text Available Background: Prosthetic reconstruction of partial maxillectomy defects is a challenging procedure that requires multidisciplinary expertise to achieve an acceptable function, speech and esthetics. This procedure improves the quality of life for the patient as a normal individual. Obturation of the defect depends on its volume and position of remaining hard and soft tissues which determine the retention, stability and support for the prosthesis. The prosthesis should be simple to handle, easy to maintain, biocompatible, light in weight and convenient for future adjustments. This case report describes a clinical case of partial maxillectomy which was successfully rehabilitated with a definitive closed hollow bulb obturator and cast metal denture base.

  20. Modified snap-on attachment with ′O-ring′ for two piece hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    C Gunasekar

    2013-01-01

    Full Text Available Restoration of near normal functions in patients who have been treated with hemimaxillectomy is generally difficult, in view of the restriction in mouth opening following healing of large surgical wound. Further, the extent and nature of the surgical defect differ from patient to patient. Thus, design of an obturator needs to be patient oriented. In this report, we describe a novel snap-on attachment with O-ring in a conventional two piece hollow bulb obturator for a 70-year-old male treated for carcinoma of the left maxilla and sinus.

  1. Closed hollow bulb obturator--one-step fabrication: a clinical report.

    Science.gov (United States)

    Buzayan, Muaiyed M; Ariffin, Yusnidar T; Yunus, Norsiah

    2013-10-01

    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing. © 2013 by the American College of Prosthodontists.

  2. Obturator or "lateral" bypass in the management of infected vascular prostheses at the groin

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2002-01-01

    Full Text Available The infection of the previously implanted vascular graft at the groin, is associated with great mortality and morbidity rate [1]. The authors present a retrospective study in which they analyzed management of infected vascular prostheses at the groin, using obturator bypass in 26 cases, and "lateral" bypass in 15 cases. The indications for obturator bypass reconstructions included: 20 infections of aorto-femoral grafts, two infected pse udoaneurysms in the groin after RTA of the superficial femoral artery, and 4 infections of iliac-femoral grafts. The indications for lateral bypass reconstructions were: infections after aorto-femoral reconstructions - 8 cases; infection after femora-popliteal reconstructions - 4 cases; infection after iliac-femoral reconstruction - 2 patients, and one infected pseudoaneurysm in the groin after RTA of the superficial femoral artery. In 3 subjects obturator bypass was performed using extraperitoneal approach while in other 23 patients transperitoneal approach was done by donor's artery. The obturator bypass was performed using a PTFE graft in 3 cases and Dacron graft in 23. The donor's artery used for obturator bypass was a noninfected proximal part of aortofemoral graft in 20 cases, and iliac artery in 6 patients. The superfical femoral artery was recipient artery for obturator bypass in 3 cases, deep femoral artery in one case, and above the knee popliteal artery in 22 cases (Figure 1. In two patients transperitoenal approach to donors artery for "lateral" bypass has been used, and in 13 cases extraperitoneal. The proximal noninfected part of aorto femoral graft was used as a donor's artery for lateral bypass in 8 patients, while common iliac artery in 7 subjects. In 5 cases recon structions were performed using PTFE grafts, in 3 using autologous saphenous vein grafts, and in 7 using Dacron grafts. The recipient artery for "lateral" bypass was deep femoral in 8 cases, superficial femoral in three patients and

  3. Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study.

    Science.gov (United States)

    Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha

    2017-07-01

    The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Spatially Resolved Hα Maps and Sizes of 57 Strongly Star-forming Galaxies at z ~ 1 from 3D-HST: Evidence for Rapid Inside-out Assembly of Disk Galaxies

    Science.gov (United States)

    Nelson, Erica June; van Dokkum, Pieter G.; Brammer, Gabriel; Förster Schreiber, Natascha; Franx, Marijn; Fumagalli, Mattia; Patel, Shannon; Rix, Hans-Walter; Skelton, Rosalind E.; Bezanson, Rachel; Da Cunha, Elisabete; Kriek, Mariska; Labbe, Ivo; Lundgren, Britt; Quadri, Ryan; Schmidt, Kasper B.

    2012-03-01

    We investigate the buildup of galaxies at z ~ 1 using maps of Hα and stellar continuum emission for a sample of 57 galaxies with rest-frame Hα equivalent widths >100 Å in the 3D-HST grism survey. We find that the Hα emission broadly follows the rest-frame R-band light but that it is typically somewhat more extended and clumpy. We quantify the spatial distribution with the half-light radius. The median Hα effective radius re (Hα) is 4.2 ± 0.1 kpc but the sizes span a large range, from compact objects with re (Hα) ~ 1.0 kpc to extended disks with re (Hα) ~ 15 kpc. Comparing Hα sizes to continuum sizes, we find =1.3 ± 0.1 for the full sample. That is, star formation, as traced by Hα, typically occurs out to larger radii than the rest-frame R-band stellar continuum; galaxies are growing their radii and building up from the inside out. This effect appears to be somewhat more pronounced for the largest galaxies. Using the measured Hα sizes, we derive star formation rate surface densities, ΣSFR. We find that ΣSFR ranges from ~0.05 M ⊙ yr-1 kpc-2 for the largest galaxies to ~5 M ⊙ yr-1 kpc-2 for the smallest galaxies, implying a large range in physical conditions in rapidly star-forming z ~ 1 galaxies. Finally, we infer that all galaxies in the sample have very high gas mass fractions and stellar mass doubling times <500 Myr. Although other explanations are also possible, a straightforward interpretation is that we are simultaneously witnessing the rapid formation of compact bulges and large disks at z ~ 1.

  5. SPATIALLY RESOLVED Hα MAPS AND SIZES OF 57 STRONGLY STAR-FORMING GALAXIES AT z ∼ 1 FROM 3D-HST: EVIDENCE FOR RAPID INSIDE-OUT ASSEMBLY OF DISK GALAXIES

    International Nuclear Information System (INIS)

    Nelson, Erica June; Van Dokkum, Pieter G.; Skelton, Rosalind E.; Bezanson, Rachel; Lundgren, Britt; Brammer, Gabriel; Förster Schreiber, Natascha; Franx, Marijn; Fumagalli, Mattia; Patel, Shannon; Labbe, Ivo; Rix, Hans-Walter; Da Cunha, Elisabete; Schmidt, Kasper B.; Kriek, Mariska; Quadri, Ryan

    2012-01-01

    We investigate the buildup of galaxies at z ∼ 1 using maps of Hα and stellar continuum emission for a sample of 57 galaxies with rest-frame Hα equivalent widths >100 Å in the 3D-HST grism survey. We find that the Hα emission broadly follows the rest-frame R-band light but that it is typically somewhat more extended and clumpy. We quantify the spatial distribution with the half-light radius. The median Hα effective radius r e (Hα) is 4.2 ± 0.1 kpc but the sizes span a large range, from compact objects with r e (Hα) ∼ 1.0 kpc to extended disks with r e (Hα) ∼ 15 kpc. Comparing Hα sizes to continuum sizes, we find e (Hα)/r e (R) > =1.3 ± 0.1 for the full sample. That is, star formation, as traced by Hα, typically occurs out to larger radii than the rest-frame R-band stellar continuum; galaxies are growing their radii and building up from the inside out. This effect appears to be somewhat more pronounced for the largest galaxies. Using the measured Hα sizes, we derive star formation rate surface densities, Σ SFR . We find that Σ SFR ranges from ∼0.05 M ☉ yr –1 kpc –2 for the largest galaxies to ∼5 M ☉ yr –1 kpc –2 for the smallest galaxies, implying a large range in physical conditions in rapidly star-forming z ∼ 1 galaxies. Finally, we infer that all galaxies in the sample have very high gas mass fractions and stellar mass doubling times <500 Myr. Although other explanations are also possible, a straightforward interpretation is that we are simultaneously witnessing the rapid formation of compact bulges and large disks at z ∼ 1.

  6. PWR pressurizer with heaters well which can be obturate and sealing process

    International Nuclear Information System (INIS)

    Godin, B.; Guicherd, L.

    1991-01-01

    Each heater well is prolongated at the end located outer the pressurizer containment by a sleeve internally tapped which is prolongated at the other end by a guiding and fixation sleeve for welding the heater. The heater well can be obturated by a threaded plug introduce in the tapped part of the sleeve after cutting the welding sleeve and extraction of the heater [fr

  7. Obturator with soft liner in the management of hard palate defect: A ...

    African Journals Online (AJOL)

    Maxillary defects are created following surgical treatment of patients with congenital defects, trauma, or neoplasm. Oral cancer is one of the more common malignanciesif detected lately massive tissues will be excised surgically and correction will be challenging. One of the treatment strategies is obturator, the retention of ...

  8. A cast partial obturator with hollow occlusal shim and semi-precision attachment

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2018-01-01

    Full Text Available A maxillofacial patient's quality of life is distorted and social integration becomes difficult. An obturator is a maxillofacial prosthesis used to close a congenital or acquired tissue defect, primarily of the hard palate and/or contiguous alveolar/soft-tissue structures. Subsequently, it restores the esthetics, speech, and function. The present clinical report aimed for the prosthetic rehabilitation of a maxillectomy defect by the incorporation of a semi-precision attachment as PRECI-SAGIX – male part of 2.2 mm on fixed partial denture (#22 and #23 teeth and matrix – plastic female part of size 2.2 mm and height 4.2 mm of yellow on cast partial in polymer base. It aids in the retention of a hollow lightweight obturator. The technique also described the method to make a bulbless obturator with a hollow self-cured acrylic resin occlusal shim. A patient is quite satisfied with bulb less, lightweight cast partial and hollow shim palatal obturator.

  9. Application of palatal RB obturator in babies with isolated palatal cleft

    Directory of Open Access Journals (Sweden)

    Radojičić Julija

    2009-01-01

    Full Text Available Background. Isolated cleft of secondary palate has a specific clinical picture due to a wide communication between the mouth and nose cavity. As a consequence of that, babies born with this malformation are often subject to infections of the upper bronchial tubes, middle ear, speech disorders, and certainly the most difficult existential problem they face at the very beginning of their lives, the impossibility of suckling (breast feeding. Such babies have to be fed with gastric probe. The difficulties in their nutrition have often been described in literature, yet a singular attitude toward early orthodontic therapy has not been adopted still. The aim of the paper was to describe a design and application of obturator immediately after the birth of a baby with isolated palatal cleft, and the role in feeding. Case report. We presented a female neonate, born on 27th December 2007, with a wide fissure in the shape of the letter U over the entire secondary palate. The baby was referred to the Stomatology Clinic due to nutrition impossibility. To avoid feeding with gastric probe, the formation of RB obturator was performed (artificial palate. Hereby, the procedure of obturator making with an explanation of its function is presented. Conclusion. The application of RB obturator and the necessary education of parents have a major role in shortening the time of breast feeding and increasing the amount of food intake and, thus, for the normal growth and development of newborn infants with isolated palate cleft.

  10. HST/WFC3 CONFIRMATION OF THE INSIDE-OUT GROWTH OF MASSIVE GALAXIES AT 0 < z < 2 AND IDENTIFICATION OF THEIR STAR-FORMING PROGENITORS AT z {approx} 3

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Shannon G.; Franx, Marijn; Muzzin, Adam [Leiden Observatory, Leiden University, P.O. Box 9513, NL-2300 AA Leiden (Netherlands); Van Dokkum, Pieter G. [Department of Astronomy, Yale University, New Haven, CT 06520-8101 (United States); Quadri, Ryan F.; Williams, Rik J. [Observatories of the Carnegie Institution of Washington, Pasadena, CA 91101 (United States); Marchesini, Danilo [Department of Physics and Astronomy, Tufts University, Medford, MA 02155 (United States); Holden, Bradford P. [UCO/Lick Observatory, University of California, Santa Cruz, CA 95064 (United States); Stefanon, Mauro, E-mail: patel@strw.leidenuniv.nl [Observatori Astronomic de la Universitat de Valencia, E-46980 Paterna, Valencia (Spain)

    2013-03-20

    We study the structural evolution of massive galaxies by linking progenitors and descendants at a constant cumulative number density of n{sub c} = 1.4 Multiplication-Sign 10{sup -4} Mpc{sup -3} to z {approx} 3. Structural parameters were measured by fitting Sersic profiles to high-resolution CANDELS HST WFC3 J{sub 125} and H{sub 160} imaging in the UKIDSS-UDS at 1 < z < 3 and ACS I{sub 814} imaging in COSMOS at 0.25 < z < 1. At a given redshift, we selected the HST band that most closely samples a common rest-frame wavelength so as to minimize systematics from color gradients in galaxies. At fixed n{sub c}, galaxies grow in stellar mass by a factor of {approx}3 from z {approx} 3 to z {approx} 0. The size evolution is complex: galaxies appear roughly constant in size from z {approx} 3 to z {approx} 2 and then grow rapidly to lower redshifts. The evolution in the surface mass density profiles indicates that most of the mass at r < 2 kpc was in place by z {approx} 2, and that most of the new mass growth occurred at larger radii. This inside-out mass growth is therefore responsible for the larger sizes and higher Sersic indices of the descendants toward low redshift. At z < 2, the effective radius evolves with the stellar mass as r{sub e} {proportional_to}M {sup 2.0}, consistent with scenarios that find dissipationless minor mergers to be a key driver of size evolution. The progenitors at z {approx} 3 were likely star-forming disks with r{sub e} {approx} 2 kpc, based on their low Sersic index of n {approx} 1, low median axis ratio of b/a {approx} 0.52, and typical location in the star-forming region of the U - V versus V - J diagram. By z {approx} 1.5, many of these star-forming disks disappeared, giving rise to compact quiescent galaxies. Toward lower redshifts, these galaxies continued to assemble mass at larger radii and became the local ellipticals that dominate the high-mass end of the mass function at the present epoch.

  11. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  12. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  13. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  14. Tape SCSI monitoring and encryption at CERN

    Science.gov (United States)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  15. Preparation and characterization of Bi-2223 tapes

    International Nuclear Information System (INIS)

    Hense, K.; Kirchmayr, H.; Kovac, P.; Lackner, R.; Mueller, M.; Pachla, W.; Pitel, J.; Polak, M.; Usak, P.

    2003-01-01

    In a concerted action between Austrian, Slovakian and Polish research institutes Bi-2223 tapes have been prepared and characterized by different physical methods. Metallographic studies by optical as well as electron microscopy, measurements of critical current (angle dependent) and losses have been performed. Properties of individual filaments extracted from multifilamentary tapes were also studied. Uniformity of local I C of these filaments were considerably lower than that of the whole tape. This indicates that improvement of filament homogeneity could improve the over all J C in tapes. The application of these tapes for optimized magnet coils will also be discussed. From these investigations a better understanding of the mechanisms, limiting the critical current could be achieved and more optimized preparation methods can be envisioned

  16. Comparative evaluation of three obturation techniques in primary incisors using digital intra-oral receptor and C.B.C.T-an in vitro study.

    Science.gov (United States)

    Akhil, Jose E J; Prashant, Babaji; Shashibushan, K K

    2018-05-10

    Successful pulpectomy in primary teeth depends on quality of obturation. It can be evaluated using digital intra-oral receptor (D.I.O.R) and cone beam computed tomography (C.B.C.T). The purposes of this study were to compare 3 different obturation techniques such as lentulospiral, insulin syringe, and endodontic plugger in primary incisors and to evaluate its quality of obturation using D.I.O.R and C.B.C.T technique. Thirty-three extracted primary incisors were biomechanically prepared and obturated with zinc oxide eugenol cement by 3 different obturation techniques. The obturation was evaluated for length of obturation and voids using D.I.O.R and C.B.C.T methods. There was a statistically significant difference between all the groups in length of obturation (P = 0.02) in both D.I.O.R and C.B.C.T. Significant differences (P = 0.03) were present in number of voids among 3 obturation techniques in C.B.C.T. Statistically more voids were observed with D.I.O.R in lentulospiral (P = 0.04) group and in insulin syringe (P = 0.02) group. Acceptable result was obtained with lentulospiral in length of obturation compared to insulin syringe and endodontic plugger technique. Insulin syringe technique resulted in increased underfilling with least number of voids. More number of voids were seen in middle one-third and least number of voids were observed at apical one third of the root among all the 3 techniques of obturation. The study concluded that void identification is improved with D.I.O.R compared to C.B.C.T. Lentulospiral reported effective length of obturation, while insulin syringe with least number of voids. D.I.O.R (2-Dimensional) is efficient in detecting voids compared to C.B.C.T (3-Dimensional) in obturated primary teeth.

  17. Effects of sociodemographic, treatment variables, and medical characteristics on quality of life of patients with maxillectomy restored with obturator prostheses.

    Science.gov (United States)

    Artopoulou, Ioli Ioanna; Karademas, Evangelos C; Papadogeorgakis, Nikolaos; Papathanasiou, Ioannis; Polyzois, Gregory

    2017-12-01

    Restoration of maxillary defects resulting from tumor ablative surgery presents a difficult challenge, with both functional and esthetic issues. Whether rehabilitation with an obturator prosthesis could significantly contribute to improved quality of life in patients with maxillary resection has been scarcely studied, with relatively small study samples. The purpose of this survey study was to assess the overall functioning of the obturator prosthesis and the effect of specific sociodemographic, medical, and treatment variables on obturator functioning and quality of life in patients with maxillectomy. Global quality of life (QOL) and satisfaction with the obturator prosthesis of 57 patients who underwent maxillectomy and prosthetic rehabilitation at the National and Kapodistrian University of Athens were assessed using 3 questionnaires: European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire C30 (QLQ-C30), the EORTC QLQ-HN35, and the obturator functioning scale. The data were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks, hierarchical multiple regression analysis, and the Spearman rank order correlation (α=.05). Satisfactory functioning of the obturator prosthesis was the most significant predictor of improved QOL (Pmaxillectomy defect (Pmaxillectomy defect had a significant effect on QOL but did not influence the functional outcome. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Outcome of zinc oxide eugenol paste as an obturating material in primary teeth pulpectomy: A systematic review

    Directory of Open Access Journals (Sweden)

    Harsha S Nalawade

    2017-01-01

    Full Text Available The aim of this systematic review is to use the principles of evidence-based dentistry to evaluate the outcome of zinc oxide eugenol (ZOE paste as an obturating material in primary teeth pulpectomies. Moderate-to-high success rates are reported with ZOE in preserving chronically infected primary teeth. However, it fails to meet many of the criteria for an ideal obturating material. Databases searched were PubMed, EBSCOhost, and Google Scholar. Articles published between January 1, 1993, and June 30, 2016, with in vivo studies for obturating materials in primary teeth pulpectomy with placement of preformed crown, reporting follow-up period of at least 12 months with clinical and radiographic success rates were selected for this review. In total, 122 articles were retrieved. After the removal of duplicates and screening, full-text articles were analyzed; of which eight articles were selected for the systematic review. No significant difference was seen in the outcome of obturating materials used in comparison with ZOE in the included studies. Outcomes of ZOE paste obtained with clinical and radiographic evaluation were similar when compared to the newer combinations of materials available for obturating primary teeth today. More number of randomized controlled clinical trials for primary teeth pulpectomies with at least 12 months follow-up period and placement of crown as final restoration need to be carried out for testing the newer materials in comparison with ZOE to conclude a suitable alternative obturating material.

  19. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  20. Hermetizing ability of the new obturating material for root canals «Real Seal» with «Resilon» technology

    Directory of Open Access Journals (Sweden)

    Makedonova Y.A.

    2012-03-01

    Full Text Available Simple, reliable and predictable obturation of root canals side by side with their cleaning and forming is an essential part of the endodontic treatment. The aim of this research is investigation of obturation density of root canals. Canals filled by means of lateral condensation of the new obturative system «Real Seal/Resilon» and by means of traditional method of canals obturation with the help of gutta-percha and sealer АН-plus. The results of the research proved a ligher hermetizing ability of the new experimental material «Real Seal» in comparison with obturation by means of gutta-percha pins. The obtained data reflects an objective picture and can be applied as a unique quality monitoring obturation of root canals.

  1. Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses.

    Science.gov (United States)

    Miyashita, Elcio Ricardo; Mattos, Beatriz Silva Câmara; Noritomi, Pedro Yoshito; Navarro, Hamilton

    2012-05-01

    The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342). Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  2. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  3. Kinesio Taping Fundamentals for the Equine Athlete.

    Science.gov (United States)

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Are the same tapes really the same? Ultrasound study of laser-cut and mechanically cut TVT-O post-operative behavior.

    Science.gov (United States)

    Rusavy, Zdenek; Masata, Jaromir; Svabik, Kamil; Hubka, Petr; Zvara, Karel; Martan, Alois

    2017-11-25

    TVT-O production has been modified to laser cutting from mechanical cutting. We compared the behavior of laser and mechanically cut tension-free vaginal tape-obturator (TVT-O) using ultrasound at various time points after surgery. This is a retrospective analysis of clinical and ultrasound data from two previously reported randomized controlled trials with TVT-O. Behavior of mechanically cut TVT-O implanted in January 2007 to November 2009 and laser-cut TVT-O implanted in May 2010 to May 2012 was assessed by ultrasound at day 1, the 2nd week, the 3rd month, and the 1st and 2nd years post-operatively. Bladder neck and tape margins positions were described by coordinates in the orthogonal system calculated from polar coordinates. Tape mobility was measured as a change in the upper and lower tape margin position from rest to maximal Valsalva. Comparison of 2-year subjective and objective surgery outcomes was also performed. In total, 68 mechanically cut and 50 laser-cut TVT-Os were implanted. Follow-up data were available from 49 and 45 women respectively. No differences in any baseline characteristics or bladder neck mobility were observed. Significantly lower tape mobility was observed on day 1 and week 2 after mechanically cut TVT-O, although subsequent mobility was comparable to laser-cut TVT-O. The subjective and objective surgery outcomes were comparable. Although without clinical significance, early postoperative behavior of the mechanically cut and laser-cut TVT-O tapes differs. The less stiff, mechanically-cut TVT-O loosens within 2 weeks of implantation, whereas the stiffer, laser-cut TVT-O keeps its tension.

  5. Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

    Science.gov (United States)

    Bogdanoff, David W.; Wilder, Michael C.

    2013-01-01

    For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

  6. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    Science.gov (United States)

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P maxillectomy can improve survival quality of patient.

  7. Prosthetic Rehabilitation of Maxillectomy Patient with Post-Surgical Obturator: A Case Report

    Directory of Open Access Journals (Sweden)

    Meena Kumari Mishra

    2015-07-01

    Full Text Available Case description: A 60 year old female patient presented to Department of Prosthodontics, CODS, BPKIHS, Dharan with a chief complain of loose obturator. History revealed that patient had undergone partial maxillectomy for squamous cell carcinoma 7 years back. The patient also has been wearing obturator which was loose when the patient reported to the department. On examination, the site of surgery was the maxillary right buccal sulcus area and a part of the hard palate including teeth number 11, 12, 13, 14, 15, 16, 17. The presented defect situation corresponded to a Class I situation (resection performed along the palatalmidline according to the Aramany classification of defects. The surgical site showed complete healing. A hollow-bulb obturator was fabricated for rehabilitation of the defect. Conclusion: The extensive surgical procedures necessary to eradicate cancer of the head and neck and to prevent local recurrence or regional metastasis often leave extremely large physical defects which present almost insurmountable surgical difficulties in restoring acceptable function or esthetics. The prosthesis rehabilitated the patient in terms of function by providing better masticatory efficiency, phonetics by adding resonance to the voice, hence improving the clarity of speech and also improved the esthetics of the patient. DOI: http://dx.doi.org/10.3126/jcmsn.v10i4.12976 JCMS Nepal 2014; 10(4:32-36

  8. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    Science.gov (United States)

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  9. Internal obturator muscle transposition for treatment of perineal hernia in dogs: 34 cases (1998-2012).

    Science.gov (United States)

    Shaughnessy, Magen; Monnet, Eric

    2015-02-01

    To evaluate the outcome of dogs with perineal hernia treated with transposition of the internal obturator muscle. Retrospective case series. 34 dogs. Medical records of dogs with perineal hernia surgically treated from 1998 to 2012 were reviewed. Diagnostic methods and surgical techniques were recorded. Dogs were assigned preoperative and postoperative clinical sign scores. Complication and recurrence rates were evaluated over time. Risk factors were determined. Median follow-up time was 345 days (range, 22 to 1,423 days). Complications were observed in 10 dogs. Tenesmus (n = 9), dyschezia (7), fecal impaction (3), stranguria (4), hematochezia (2), urinary incontinence (2), diarrhea (1), urinary tract infection (1), and megacolon (1) occurred following surgery. Bladder retroflexion at the time of initial evaluation or surgery was not a risk factor for complication (hazard ratio, 1.72). One year after surgery, 51.2% dogs were free of complications. Three dogs developed a perineal hernia on the contralateral side between 35 and 95 days after surgery. The 1-year recurrence rate was 27.4%. Median time for recurrence was 28 days after surgery (range, 2 to 364 days). Postoperative tenesmus was a risk factor for the development of recurrence (hazard ratio, 2.29). Internal obturator muscle transposition was used for primary repair of perineal hernia in dogs. Recurrence was recorded as long as 1 year after surgery. Tenesmus was a risk factor for the development of recurrence after treatment of perineal hernia with internal obturator muscle transposition.

  10. Tape Cassette Bacteria Detection System

    Science.gov (United States)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  11. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    Science.gov (United States)

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  12. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri, U.T. Ifthikar Ali, Madhusmita Koch, Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  13. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  14. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  15. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  16. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    International Nuclear Information System (INIS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-01-01

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I_c measurement, we found that our new multi-filamentary tape could provide almost equal I_c compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  17. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  18. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  19. The role of succinylcholine in the prevention of the obturator nerve reflex during transurethral resection of bladder tumors

    International Nuclear Information System (INIS)

    Cesur, M.; Erdem, Ali F.; Alici, Haci A.; Yuksek, Mustafa S.; Yapanoglu, T.; Aksoy, Y.

    2008-01-01

    Objective was to present our 8 year experience in the prevention of the obturator nerve reflex during transurethral resection of bladder tumors. This study was performed in Ataturk University Hospital between 1999 and 2007. We retrospectively reviewed the records of 89 patients with inferolateral bladder tumors, who underwent transurethral resection under epidural or general anesthesia and requested obturator nerve reflex inhibition. Epidural anesthesia was administered to 57 patients, while the remaining 32 patients underwent general anesthesia via mask; and succinylcholine was administered prior to resection. Of the 57 patients received epidural anesthesia, 18 were diagnosed as inferolateral bladder tumors during endoscopy and had to undergo general anesthesia. Obturator nerve block was attempted preoperatively in 39 patients. However, a nerve identification failure, hematoma and 4 obturator nerve reflex events, despite the block, were observed and these patients were subjected to general anesthesia with succinylcholine. Fifty-six patients (32 patients initially had general anesthesia and 24 converted from epidural to general anesthesia) were all given succinylcholine prior to resection. Due to its mechanisms of action, succinylcholine is completely effective and represents a simple alternative to obturator nerve block. No contraction was observed in any patient given succinylcholine. (author)

  20. Clinical and radiographic evaluation of zinc oxide with aloe vera as an obturating material in pulpectomy: An in vivo study

    Directory of Open Access Journals (Sweden)

    Abhishek Khairwa

    2014-01-01

    Full Text Available Background: Pulp therapy for pulpally involved primary teeth continues to be a challenge to clinicians. One of the major areas of continued research is in the area of finding obturating materials to suit the specific properties of these teeth. Zinc oxide eugenol is used frequently in pulpectomy for the obturation of the primary teeth. Aims: To evaluate clinically and radiographically a mixture of zinc oxide eugenol and aloe vera as an obturating material. Materials and Methods: A total of 50 children, aged between 4 and 9 years, who were screened for unilateral or bilateral carious deciduous molars were studied. Out of these, 15 children were randomly selected for endodontic treatment. Obturation was done with a mixture of zinc oxide powder and aloe vera gel. Clinical and radiographic evaluation was done after 7 days, 1 month, 3 months, 6 months, and 9 months. The data were statistically analyzed. Results and Conclusion: Endodontic treatment using a mixture of zinc oxide powder and aloe vera gel in primary teeth has shown good clinical and radiographic success. A detailed observational study with longer follow-up will highlight the benefits of aloe vera in primary teeth as an obturating medium.

  1. Strategy for robot motion and path planning in robot taping

    Science.gov (United States)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  2. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  3. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Science.gov (United States)

    Mohamed Usman, Jafar Abdulla; Ayappan, Anuroopa; Ganapathy, Dhanraj; Nasir, Nilofer Nisha

    2013-01-01

    Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator. PMID:23533823

  4. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Directory of Open Access Journals (Sweden)

    Jafar Abdulla Mohamed Usman

    2013-01-01

    Full Text Available Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator.

  5. Health-related quality of life after maxillectomy: obturator rehabilitation compared with flap reconstruction.

    Science.gov (United States)

    Breeze, J; Rennie, A; Morrison, A; Dawson, D; Tipper, J; Rehman, K; Grew, N; Snee, D; Pigadas, N

    2016-10-01

    Health-related quality of life (QoL) reported by patients has the potential to improve care after ablative surgery of the midface, as existing treatment algorithms still generally revolve around outcomes assessed traditionally only by clinicians. Decisions in particular relate to reconstruction with a flap compared with rehabilitation with an obturator, the need for adjuvant treatment, and morbidity related to the size of the defect. We prospectively collected health-related QoL assessments for 39 consecutive patients treated by maxillectomy between 01 January 2010 and 31 December 2014 using the University of Washington Quality of Life Questionnaire, and who had a mean (SD) duration of follow-up of 14 (4). We made sub-group analyses using paired t tests and analysis of variance (ANOVA) to compare reconstruction with a flap with rehabilitation with obturators, size of the vertical defect, and whether adjuvant treatment with radiotherapy or chemoradiotherapy adversely affected it. Overall there was a significant decrease in health-related QoL after treatment compared with before (p<0.001), but there was no significant difference in the effects of any of the paired reconstructive and rehabilitation treatments on it. Obturators remain an important option for rehabilitation in selected patients in addition to reconstruction with a flap. We found that neither increasing the size of the vertical defect (in an attempt to ensure clear margins) nor the use of postoperative radiotherapy seemed to have any adverse effect on QoL. More patients are required before we can conclude that the potential survival benefits of such measures may outweigh any adverse effects. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

    Directory of Open Access Journals (Sweden)

    Özgür Genç

    2011-08-01

    Full Text Available OBJECTIVE: The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth. MATERIAL AND METHODS: 85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device. RESULTS: All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (p<0.05. Lightspeed ranked in between. Leakage was similar for all techniques at either period. However, all groups leaked significantly more at 3 months compared to 1 week (p<0.05. CONCLUSIONS: Despite statistically significant differences found among the techniques, deviations from the predetermined level were small and clinically acceptable for all techniques. Leakage following obturation was comparable in all groups.

  7. Objective clinical assessment of change in swallowing ability of maxillectomy patients when wearing obturator prostheses.

    Science.gov (United States)

    Matsuyama, Miwa; Tsukiyama, Yoshihiro; Koyano, Kiyoshi

    2005-01-01

    Evaluation of treatment outcome is important in maxillofacial rehabilitation. Although eating is one of the oral functions that most strongly influences patients' quality of life, only a few reports exist on the objective assessment of swallowing for maxillectomy patients. The purpose of this study was to identify changes in the swallowing ability of maxillectomy patients when wearing obturator prostheses through the use of an objective clinical assessment. The swallowing ability of 38 postmaxillectomy patients consecutively treated with obturator prostheses was objectively evaluated with the "water-drinking test" that was developed for the assessment of dysphagia patients after cerebrovascular disease. In this test, the subjects were instructed to drink 30 mL of water in one swallow. The profile was evaluated with the combination of the time required for drinking the water and the incidence of cough reflex. Statistical analysis was performed using the Wilcoxon signed-rank test, the paired t test, and the Chi-square test with StatView 5.0 for the Macintosh. Performance improved significantly when the patients wore prostheses (P = .0026, Wilcoxon signed-rank test). The mean drinking times without and with prostheses were 8.2 +/- 6.3 s and 5.0 +/- 3.5 s, respectively. Drinking time was shortened significantly when the prosthesis was worn (P = .0002, paired t test). The assessment of behavior and episodes revealed that the swallowing ability of the maxillectomy patients was significantly improved when a prosthesis was worn (P = .0002, Chi-square test). The swallowing ability of maxillectomy patients was quantitatively and qualitatively improved with obturator prostheses.

  8. A method for obturating microscopic ports in parts submitted to stresses, e.g. heat-exchangers

    International Nuclear Information System (INIS)

    Halstead, W.D.

    1975-01-01

    The invention relates to the obturation of cracks in metal-parts. It refers to a method for obturating the micropores of a member adapted to be submitted to stresses, said method being characterized in that it comprises the steps of exposing one surface of said member to a mixture of nickel-carbonyl and hydrogen sulfide with an inert gaseous carrier, and exposing the member other surface to air or nitrogen with oxygen or steam, the gases being at substantially the same pressure and at a temperature of from 290 to 330 deg K. This can be applied to the obturation of micropores in the heat exchangers of sodium cooled nuclear reactor [fr

  9. [Modern tendencies in surgical treatment of patients with obturation jaundice complicated by hepatic insufficiency].

    Science.gov (United States)

    Starosek, V N; Khil'ko, S S; Vlakhov, A K

    2009-04-01

    The article is devoted to the problem of efficacy of the hepatic insufficiency (HI) prophylaxis and treatment methods in obturation jaundice. The role of energy-depending processes and the oxygen deficiency in tissues in the HI occurrence and progressing, the possibilities of medicinal correction of such disorders were studied up. The authors follow the concept of expediency of the oxygen-bearing preparations, which improve the erythrocytes function and oxygen delivery to the tissues in combination with miniinvasive decompression of bilioefferent ways, incorporation into the treatment complex of HI of mechanic genesis.

  10. Interim obturator in an infant with Treacher Collins syndrome: Review and chairside modification in impression making

    Directory of Open Access Journals (Sweden)

    Sudhir Bhandari

    2011-01-01

    Full Text Available Treacher Collins syndrome has been described as a syndrome involving 1st and 2nd branchial arches, affecting various organs in the craniofacial region. Affected infants report with nasal regurgitation and minimal dietary intake due to cleft palate, consequently show delayed and retarded growth. The situation is further complicated when the repair of the palatal defect is postponed due to delayed milestones. At this juncture, it is of paramount importance to intervene prosthetically and close the defect with the aid of an interim obturator. Herein we describe a simple, yet successful, chairside approach to make an impression of an infant without the aid of any kind of anesthesia.

  11. Threading the Needle: Intrapelvic Displacement of a Femoral Neck Fracture through the Obturator Foramen

    Directory of Open Access Journals (Sweden)

    Gautham Prabhakar

    2018-01-01

    Full Text Available Despite timely and appropriate management, displaced femoral neck fractures are often devastating injuries for the young patient. The risk of negative sequelae is further amplified with increasing displacement and vertical fracture patterns. Open anatomic reduction with rigid internal fixation is essential to maximize the healing potential in displaced fractures of the femoral neck. Successful primary osteosynthesis of significantly displaced femoral neck fractures in the young patient has been reported in the literature. We present a unique case of open reduction and internal fixation of a high-energy femoral neck fracture with extrusion of the head through the obturator foramen into the pelvis without associated acetabular or pelvic injury.

  12. Rehabilitation of patient with acquired maxillary defect, using a closed hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Abhilasha S Bhasin

    2011-01-01

    Full Text Available Palliative care means providing support and care for patients with life-threatening or debilitating illness so that they can live their life as comfortably as possible. The fact that cure is no longer a reality does not mean that care cannot be made available. Partial maxillectomy defect presents a prosthodontic challenge in terms of re-establishing oronasal separation. Such defect has direct effect on cosmetic, function and psychology of the patient. This article describes step by step clinical and laboratory procedures involved in the rehabilitation of a hemimaxillectomy patient, using a definitive closed hollow bulb obturator, which improved his physical, emotional, functional, social and spiritual needs.

  13. System for sampling liquids in small jugs obturated by screwed taps

    International Nuclear Information System (INIS)

    Besnier, J.

    1995-01-01

    This invention describes a machine which samples automatically liquids in small jugs obturated by screwed taps. This device can be situated in an isolated room in order to work with radioactive liquids. The machine can be divided in three main parts: a module to catch the jug, in order to take and fix it, a module to open and to close it, and a module to sample. The later takes the liquid thanks to a suction device and puts it in a container, in order to analyse the sample. (TEC)

  14. How PE tape performs under concrete coating

    International Nuclear Information System (INIS)

    Dritt, H.J.

    1984-01-01

    The program objectives were to evaluate the performance of polyethylene tape plant coating and fusion bonded epoxy powder systems with particular respect to the following: 1. Concrete coating application procedures; 2. The shear resistance during laying and retrieving operations of the coating at the various interfaces (a) Pipe and anti-corrosion coating; (b) Anti-corrosion coating and outerwrap; (c) Overlap areas of the anti-corrosion and outerwrap layers; (d) Between concrete and the various corrosion coatings during laying and retrieving operations. 3. Resistance to damage of the coating as a consequence of cracking or slippage of the concrete weight coating. 4. Ability of various coatings to withstand the damage during concrete application by both impact and compression methods; 5. Evaluation of tape and shrink sleeve joint coatings at the cut-back area as well as performance of tape under hot asphalt coating

  15. APICAL SEAL BETWEEN ADHESIVE ROOT CANAL OBTURATION SYSTEM AND GUTTA-PERCHA/AH-PLUS SEALER: AN IN VITRO COMPARISON STUDY

    Directory of Open Access Journals (Sweden)

    Girish

    2016-03-01

    Full Text Available BACKGROUND Three dimensional obturation of the root canal is important for success of root canal treatment. Microleakage is one of the reason for root canal failure. Numerous materials have been used for obturation of which Gutta-percha is the most successful with variety of sealers. One of the recent material to further improve root canal treatment success rate is use of Resilon with Epiphany root canal sealer to apply adhesive concepts in to endodontics. An adhesive bond forms between Epiphany sealer, Resilon and dentin, making it monolithic hence less microleakage if any significantly. METHODS 60 single rooted mandibular premolars were dissected at cement enamel junction with diamond disc. Root canals were explored and working length measured using K file. Root canals of all 60 samples were prepared with ProTaper and irrigated with 5% sodium hypochlorite and 17% EDTA solution. Teeth were divided in to group A and B, each having 30 samples. Group A teeth obturated with Resilon Epiphany obturation system and group B with Gutta-percha and AH-plus sealer. All specimens were stored in incubator for 30 days. Clearing process of samples done with Robertson’s technique to make them transparent. All the specimens were immersed in 2% methylene blue dye solution for 7 days. Specimens were then examined under stereomicroscope with 10x magnification to measure dye penetration in mm with image analysis software. The data collected were analysed statistically. RESULTS This study showed that Resilon Epiphany group has a mean leakage of 1.2307, while the Gutta-percha/AH-plus had a mean leakage of 3.6133. There was statistically significant differences between Resilon and Gutta-percha groups. CONCLUSIONS 1. Resilon Epiphany group showed less apical microleakage than Gutta-percha/AH-plus obturation. 2. Based on result obtained it is suggested that Resilon Epiphany can be recommended for root canal obturation.

  16. Prosthetic rehabilitation of the dentate maxillectomy patient from a delayed surgical to an interim obturator: A clinical case report

    Directory of Open Access Journals (Sweden)

    Angleena Y Daniel

    2015-01-01

    Full Text Available The surgical management of maxillary pathosis results in direct communication between the oral and nasal cavity, imposing problems such as nasal regurgitation, unintelligent speech, difficulty in deglutition and compromised esthetics. A restoration of these defects is not always possible surgically, but prosthetic rehabilitation is an established treatment modality. Early rehabilitation can improve the quality of life and reduce the psychological trauma caused by surgical excision. Surgical and interim obturators placed during the initial phase can improve the outcome of the definitive prosthesis. This article presents a case report of a patient with partial maxillectomy who has been rehabilitated with a delayed surgical and an interim obturator.

  17. Monoblock Obturation Technique for Non-Vital Immature Permanent Maxillary Incisors Using Mineral Trioxide Aggregate: Results from Case Series

    International Nuclear Information System (INIS)

    Iqbal, Z.; Qureshi, A. H.

    2014-01-01

    Ten patients presented with non-vital immature teeth for root canal treatment. In all these cases the pre-operative clinical examination revealed apical periodontitis with a buccal sinus tract of endodontic origin. These cases were treated by a mineral trioxide aggregate (MTA) monoblock obturation technique. Follow-up evaluations were performed at 1 - 2 years after treatment. Eight out of 10 cases were associated with periradicular healing at follow-up evaluation. Mineral trioxide aggregate Monoblock obturation technique appears to be a valid material to obtain periradicular healing in teeth with open apices and necrotic pulps. (author)

  18. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  19. Modelling of Tape Casting for Ceramic Applications

    DEFF Research Database (Denmark)

    Jabbari, Masoud

    was increased by improving the steady state model with a quasi-steady state analytical model. In order to control the most important process parameter, tape thickness, the two-doctor blade configuration was also modeled analytically. The model was developed to control the tape thickness based on the machine...... for magnetic refrigeration applications. Numerical models were developed to track the migration of the particles inside the ceramic slurry. The results showed the presence of some areas inside the ceramic in which the concentration of the particles is higher compared to other parts, creating the resulting...

  20. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  1. Randomized controlled study of MONARC® vs. tension-free vaginal tape obturator (TVT-O®) in the treatment of female urinary incontinence: comparison of 3-year cure rates.

    Science.gov (United States)

    Park, Yoo Jun; Kim, Duk Yoon

    2012-04-01

    Transobturator approaches to midurethral sling surgery are one of the most commonly performed operations for female stress urinary incontinence throughout the world. However, very few results of randomized clinical trials of transobturator midurethral sling surgery (MONARC vs. TVT-O) for the treatment of female urinary incontinence have been reported. In this study, we compared the 3-year follow-up cure rates of these two procedures. From July 2006 to June 2008, 74 patients who had undergone MONARC (35 patients) or TVT-O (39 patients) were included in the study and were analyzed prospectively. The mean follow-up duration of both groups was 39.2 months. Preoperative and postoperative evaluations included physical examination, uroflowmetry and postvoid residual measurement, involuntary urine loss with physical activity, and urinary symptoms. Cure of female urinary incontinence was defined as patient report of no loss of urine upon physical activity. The patients' satisfaction after treatment was rated as very satisfied, satisfied, equivocal, and unsatisfied. Very satisfied and satisfied were considered as the satisfied rate. There were no significant differences in preoperative patient characteristics, postoperative complications, or success rate between the two groups. The cure rate of the MONARC and TVT-O groups was 85.7% and 84.6%, respectively. The patient satisfaction (very satisfied, satisfied) rate of the MONARC and TVT-O groups was 82.8% and 82.1%, respectively. The MONARC and TVT-O procedures were equally efficient for the treatment of female urinary incontinence, with maintenance of high cure rates for 3 years. Longer follow-up is needed to confirm these results.

  2. Evaluation of the Sealing Ability of Three Obturation Techniques Using a Glucose Leakage Test

    Directory of Open Access Journals (Sweden)

    Katarzyna Olczak

    2017-01-01

    Full Text Available The aim of this study was to evaluate the sealing ability of three different canal filling techniques. Sixty-four roots of extracted human maxillary anterior teeth were prepared using ProTaper® rotary instruments. The specimens were then randomly divided into 3 experimental groups (n=16 and 2 control groups (n=8. The root canals were filled using cold lateral compaction (CLC group, continuous wave condensation technique using the Elements Obturation Unit® (EOU group, and ProTaper obturators (PT group. For the negative control group, 8 roots were filled using lateral compaction as in the CLC group, and the teeth were covered twice with a layer of nail varnish (NCG group. Another 8 roots were filled using lateral compaction, but without sealer, and these were used as the positive control (PCG group. A glucose leakage model was used for quantitative evaluation of microleakage for 24 hours and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12 weeks. No significant difference in the cumulative amount of leakage was found between the three experimental groups at all observation times. The lateral condensation of cold gutta-percha can guarantee a similar seal of canal fillings as can be achieved by using thermal methods, in the round canals.

  3. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    Directory of Open Access Journals (Sweden)

    Georgios Kouveliotis

    2017-01-01

    Full Text Available Introduction: Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case: A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heatcured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion: Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  4. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain.

    Science.gov (United States)

    Chye, Cien-Leong; Liang, Cheng-Loong; Lu, Kang; Chen, Ya-Wen; Liliang, Po-Chou

    2015-01-01

    Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF) is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain. Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment) according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS), Oxford hip scores (OHS), and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment. At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement. When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning.

  5. Application of microcomputed tomography for quantitative analysis of dental root canal obturations

    Directory of Open Access Journals (Sweden)

    Anna Kierklo

    2014-03-01

    Full Text Available Introduction: The aim of the study was to apply microcomputed tomography to quantitative evaluation of voids and to test any specific location of voids in tooth’s root canal obturations. Materials and Methods: Twenty root canals were prepared and obturated with gutta-percha and Tubli-Seal sealer using the thermoplastic compaction method (System B + Obtura II. Roots were scanned and three-dimensional visualization was obtained. The volume and Feret’s diameter of I-voids (at the filling/dentine interface and S-voids (surrounded by filling material were measured.Results: The results revealed that none of the scanned root canal fillings were void-free. For I-voids, the volume fraction was significantly larger, but their number was lower (P = 0.0007, than for S-voids. Both types of voids occurred in characteristic regions (P < 0.001. I-voids occurred mainly in the apical third, while S-voids in the coronal third of the canal filling.Conclusions: Within the limitations of this study, our results indicate that microtomography, with proposed semi-automatic algorithm, is a useful tools for three-dimensional quantitative evaluation of dental root canal fillings. In canals filled with thermoplastic gutta-percha and Tubli-Seal, voids at the interface between the filling and canal dentine deserve special attention due to of their periapical location, which might promote apical microleakage. Further studies might help to elucidate the clinical relevance of these results.

  6. Distanced Data: Transcribing Other People's Research Tapes

    Science.gov (United States)

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  7. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  8. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  9. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  10. "Space slitter" for film or tape

    Science.gov (United States)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  11. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  12. An in vitro Comparison of Bond Strength of Different Sealers/Obturation Systems to Root Dentin Using the Push-Out Test at 2 Weeks and 3 Months after Obturation.

    Science.gov (United States)

    Yap, Wai Ying; Che Ab Aziz, Zeti Adura; Azami, Noor Hayati; Al-Haddad, Afaf Yahya; Khan, Asfand Ali

    2017-01-01

    To evaluate the push-out bond strength and failure modes of different sealers/obturation systems to intraradicular dentin at 2 weeks and 3 months after obturation compared to AH Plus®/gutta-percha. A total of 180 root slices from 60 single-canal anterior teeth were prepared and assigned to 5 experimental groups (n = 36 in each group), designated as G1 (AH Plus®/gutta-percha), G2 (TotalFill BC™ sealer/BC-coated gutta-percha), G3 (TotalFill BC™ sealer/gutta-percha), G4 (EndoREZ® sealer/EndoREZ®-coated gutta-percha), and G5 (EndoREZ® sealer/gutta-percha). Push-out bond strengths of 18 root slices in each group were assessed at 2 weeks and the other 18 at 3 months after obturation using a universal testing machine. Data were analyzed using repeated measures ANOVA. An independent t test was used to compare the mean push-out bond strength for each group at 2 weeks and 3 months after obturation. The mean push-out bond strengths of G4 and G5 were significantly lower than those of G1, G2, and G3 (p strengths of G2 (3.69 ± 1.20 MPa) and G3 (2.84 ± 0.83 MPa) were higher at 3 months compared to 2 weeks after obturation (G2: 1.74 ± 0.43 MPa, G3: 1.33 ± 0.29 MPa). The TotalFill BC™ obturation system (G2) and the TotalFill BC™ sealer/gutta-percha (G3) showed comparable bond strength to AH Plus®. Their bond strength increased over time, whereas the EndoREZ® obturation system (G4) and EndoREZ sealer (G5) had low push-out bond strength which decreased over time. © 2017 The Author(s) Published by S. Karger AG, Basel.

  13. Effect of binder concentration and blade gap on Yttria stabilized Zirconia tapes obtained by tape casting

    Energy Technology Data Exchange (ETDEWEB)

    Mena Garcia, J.; Reyes Rojas, A.; Rodriguez Gonzalez, C.A.; Hernandez Paz, J.; Garcia Casillas, P.E.; Enriquez Carrejo, J.L.; Camacho Montes, H.

    2016-07-01

    The tape casting method has kept its interest over the years due to the wide spectrum of its applications and its economic viability in comparison to other techniques focused on micrometric thin films. Two key parameters for tape casting are the binder relative amount and the Dr. Blade gap. The binder relative amount has a strong influence on the rheological properties for the ceramic YSZ slurry (ethanol, butanone, TEA, PVB, PEG, DEP). The coefficient K and the exponent m of the Cross model are reported to be inside the ranges 152.25-231.12 and 0.00987-0.26646 for PVB binder weight percentage concentrations between 6% and 12%. It is possible to describe the ceramic tape thickness dependence by means of a linear relation depending on the Dr. Blade gap whose linear coefficients (slope) are equal to 0.0350 and 0.2171 for green and sintered tapes respectively, with the YSZ slurry of the present work. (Author)

  14. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  15. An ex vivo comparison of pressures within dental pulp space using conventional anesthetic technique versus needle-mounted obturator.

    Science.gov (United States)

    Grubbs, S Lee; Alley, Larry W; Eleazer, Paul D

    2014-07-01

    The intrapulpal (IP) injection technique is 1 of several ways of obtaining profound anesthesia. There is evidence to suggest that pressure is the primary factor in obtaining anesthesia using IP injection. This is an ex vivo comparison of pressures within dental pulp space using the conventional anesthetic technique versus a needle-mounted obturator technique. Twenty extracted anterior and premolar teeth were accessed with a high-speed 169L bur. A saline-filled tube connected to a digital pressure gauge was attached to the apical 10 mm of each tooth in a fixed mount. One operator performed all the injections under moderate pressure. Each tooth was injected twice; first, the tooth was given an IP injection with a normal setup, and then the same tooth was given an IP injection with the modified obturator syringe. The pressure at the apex was recorded for each tooth. A paired sample t test was completed to determine statistical significance. The pressure generated was considerably higher for the obturator group in every tooth when compared with the normal group (P < .001). IP injection with the obturator resulted in increased pressure at the apex of each tooth. This pressure increase may allow for increased anesthesia when IP injections are indicated. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Influence of the spatulation of two zinc oxide-eugenol-based sealers on the obturation of lateral canals

    Directory of Open Access Journals (Sweden)

    Pécora Jesus Djalma

    2002-01-01

    Full Text Available The objective of this research was to evaluate, in vitro, the importance of the correct manipulation of endodontic sealers, correlating it with flow rate and with the consequent obturation of root canals. Twenty-four human canines were prepared, 1 mm from the apex, with K-files up to size 50, by means of the step-back technique. Six lateral canals were then drilled in each tooth, with size 10 file fixed to a low-speed handpiece. The teeth were randomly divided into 4 groups, and root canals were obturated either with the EndométhasoneÒ sealer or Grossman sealer, prepared at ideal or incorrect clinical consistency. After obturation by means of the lateral condensation technique, the teeth were radiographed and evaluated as to the number of sealed lateral canals. Statistical analysis revealed significant differences (p < 0.001 between the tested sealers, and indicated the higher capacity of the well-manipulated Grossman sealer to fill lateral canals. It can be concluded that the flow rate of a sealer and its correct manipulation are very important for the satisfactory obturation of lateral canals.

  17. Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation:a scanning electron microscopy study

    Institute of Scientific and Technical Information of China (English)

    Jun Sang Yoo; Qiang Zhu; Kee-Yeon Kum; Seok-Woo Chang; So Ram Oh; Hiran Perinpanayagam; Sang-Min Lim; Yeon-Jee Yoo; Yeo-Rok Oh; Sang-Bin Woo; Seung-Hyun Han

    2014-01-01

    The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate (MTA) was studied by scanning electron microscopy (SEM). Single-rooted human premolars (n560) were instrumented to an apical size #50/0.06 using ProFile and treated as follows:Group 1 (n510) was filled with phosphate buffered saline (PBS);Group 2 (n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS;Group 3 (n520) was obturated orthograde with a paste of OrthoMTA (BioMTA, Seoul, Korea) and PBS;and Group 4 (n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoMTA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material (IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoMTA-filled roots (Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots (Group 4). Therefore, the orthograde obturation of root canals with OrthoMTA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization.

  18. Comparative assessment of the area of sealer voids in single cone obturation done with mineral trioxide aggregate, epoxy resin, and zinc-oxide eugenol based sealers

    Directory of Open Access Journals (Sweden)

    Anisha Kumar

    2016-01-01

    Full Text Available Introduction: Voids in the sealer mass have the potential to allow leakage through obturation. They are more critical in single cone (SC obturation as the volume of sealer used in this obturation is larger when compared to other obturations. Aim: To compare the area of voids in mineral trioxide aggregate (MTA-based, resin-based, and zinc oxide-eugenol-based sealers when employed with SC obturation technique. Materials and Methods: Fifteen teeth were cleaned and shaped and divided into three groups for SC obturation using MTA Fillapex, AH26, and Pulpdent sealers, respectively. The obturated teeth were sectioned at apical, middle, and coronal third, and area of voids in the sealer was assessed using a stereomicroscope and digital images and image software. The results were statistically analyzed using SPSS software and Kruskal-Wallis and Mann-Whitney tests. Results: The three tested sealers showed voids in all the sections except MTA Fillapex, which was void free in apical and middle sections. There were significant differences between these sealers regarding their section wise area of voids (P < 0.05. Similarly, there were significant differences in their overall area of voids (P < 0.05 with MTA Fillapex showing significantly least area of voids followed by AH26. Conclusions: SC obturation with MTA Fillapex sealer, which showed void free apical and middle third sections, had significantly least area of voids in the sealer followed by the one with AH26 sealer, whereas SC obturation with Pulpdent sealer had significantly most area of voids.

  19. Neurofibroma involving obturator nerve mimicking an adnexal mass: a rare case report and PRISMA-driven systematic review.

    Science.gov (United States)

    Chao, Wei-Ting; Liu, Chia-Hao; Chen, Yi-Jen; Wu, Hua-Hsi; Chuang, Chi-Mu; Wang, Peng-Hui

    2018-02-09

    Pelvic masses are a common gynecologic problem, and majority of them are diagnosed as ovarian tumors finally. Sometimes, it is hard to distinguish the origin of these pelvic masses. The following case is a solitary neurofibroma arising from the right-side obturator nerve, which was impressed as a right-side ovarian tumor initially. We reported this case, and also performed a PRISMA-driven systematic review to summary the similar cases in the literature. This review includes image, molecular and pathological findings and outcome of neurofibroma. A 33-year-old woman with a regular menstrual period denied any symptoms or signs. During her physical check-up, image examination revealed a right-side heterogeneous pelvic mass; it was suggestive of a complex of right-side ovarian tumor. A provisional diagnosis of retroperitoneal pelvic mass, probably a benign ovarian tumor, was made. Excision of the right-side pelvic mass was performed. We sent the specimens for frozen pathology, which indicated neurofibroma and lipomatous tumor and that the possibility of liposarcoma cannot be excluded. A segment of the obturator nerve was attached to the tumor and was severed. A right-side obturator nerve tear during tumor excision was observed, and a neurosurgeon was consulted for obturator nerve grafting and repair. The patient complained of mild weakness and paresthesia affecting the right leg, and we consulted a rehabilitation doctor for neuron injury. The patient's recovery was uneventful, and she was discharged eight days after the drain was removed. Further rehabilitation treatment was arranged. A neurofibroma is an uncommon pelvic retroperitoneal tumor, and it can be misdiagnosed as an adnexal mass. To our knowledge, this is a rare case of a solitary neurofibroma arising from the obturator nerve. It usually does not have any neurological deficit. We present this case to demonstrate that pelvic neurofibroma can be mistaken for an adnexal mass. This fact should be borne in mind

  20. IN VITRO COMPARISON OF GUTTA-PERCHA-FILLED AREA PERCENTAGES IN ROOT CANALS INSTRUMENTED AND OBTURATED WITH DIFFERENT TECHNIQUES*

    Directory of Open Access Journals (Sweden)

    Ayça YILMAZ

    2017-04-01

    Full Text Available Purpose: To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA. Materials and Methods: One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20 according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC, G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. Results: The mean of the PGFA in Thermafil (G2, ProTaper-Obturator (G5 and HEROfill (G8 groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. Conclusion: The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  1. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    Science.gov (United States)

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  2. Case presentation of two maxillectomy patients restored with two-piece hollow bulb obturator retained using two different types of magnets

    Directory of Open Access Journals (Sweden)

    B Devi Parameswari

    2017-01-01

    Full Text Available Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  3. Case Presentation of Two Maxillectomy Patients Restored with Two-piece Hollow Bulb Obturator Retained using Two Different Types of Magnets.

    Science.gov (United States)

    Parameswari, B Devi; Rajakumar, M; Jagadesaan, N; Annapoorni, H

    2017-11-01

    Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  4. EFFECT OF KINESIO TAPE VERSUS ATHLETIC TAPE ON MYOELECTRIC ACTIVITY OF ANKLE MUSCLES IN PATIENTS WITH CHRONIC ANKLE SPRAIN

    Directory of Open Access Journals (Sweden)

    Asmaa F Abdelmonem

    2018-04-01

    Full Text Available Background: Sprained ankle a common orthopedic injury. The standard treatment for ankle sprains remains nonoperative. Ankle taping was used to protect and prevent ligaments excessive strain. So, the current study aimed at investigating the effect of spa-care Kinesio tape versus standard white athletic tape on myoelectric activities (EMG of ankle evertors (peroneus longus and invertors (tibialis anterior in a chronic ankle sprain. Methods: A convenient sample of 30 patients with a chronic ankle sprain (18 females and 12 males were included in this study. Their mean age ±SD was 24 ±1.2 years. Their height was 175±4.8 cm among men & 163±5.2 cm for females, and weight was 85±5.2 kg for males & 74±5.5 kg for women. It was a within-group design in which the same participant experienced the two types of taping compared to no taping condition. Root mean square (RMS was measured while participants were moving the isokinetic dynamometer at an angular velocity of 120°/sec using concentric contraction mode through full ankle range of motion. The EMG (RMS of evertors and invertors was measured immediately after the three taping ways (no tape, Kinesio tape, and athletic tape with a one-week interval between each taping. Results: Spa-care Kinesiotape significantly reduced evertors and invertors EMG (RMS compared with no tape or athletic tape in patients with chronic ankle sprain. Mean± SD of the evertors was 0.7 (±0.1 for no tape and 0.58 (±0.2 for Kinesio tape. The P value was 0.000 for kinesio tape in evertors compared with no tape. Also, mean± SD of the invertors was 0.87 (±0.23 for no tape, and 0.54 (±0.1 for Kinesio tape and the P value was 0.001 for Kinesio tape in invertors compared with no tape. Conclusion: Spa-care Kinesio tape may be useful for reducing EMG activity of ankle muscles in a chronic ankle sprain.

  5. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  6. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...... of the side-by-side tape casting technique: recognising critical parameters which affect the quality of a graded tape, shape and position of the interface area. Studied parameters can be divided into two categories: operational parameters and slurry formulation optimisation. The operational parameters...

  7. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    during the tape processing, (3) a study of the grain boundaries on an atomic scale, including intergrowth investigations. Tapes with different process parameters have been compared with respect to the microstructure. A fully processed tape has on the average 50% thicker Bi-2223 grains than a tape after......The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  8. Use of video taping during simulator training

    International Nuclear Information System (INIS)

    Helton, M.; Young, P.

    1987-01-01

    The use of a video camera for training is not a new idea and is used throughout the country for training in such areas as computers, car repair, music and even in such non-technical areas as fishing. Reviewing a taped simulator training session will aid the student in his job performance regardless of the position he holds in his organization. If the student is to be examined on simulator performance, video will aid in this training in many different ways

  9. The four silo STK Powderhorn Tape Library

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    A view of the four silo Storage Tek (STK) Powderhorn Tape Library and its control area. Each silo can contain up to 6000 storage slots with cartridges of 10, 20, 25 or 50 GB capacity, reaching a data transfer rate of up to 12 Mbytes/sec. This will form part of the Grid system that will process the huge amounts of data produced at the LHC.

  10. Perceived Organizational Red Tape and Organizational Performance in Public Services

    DEFF Research Database (Denmark)

    Jacobsen, Christian Bøtcher; Jakobsen, Mads Leth

    2018-01-01

    The claim that perceived organizational red tape hampers public services has become a central theme in public administration research. Surprisingly, however, few scholars have empirically examined the impact of perceived red tape on organizational performance. This study empirically analyzes how...... perceived organizational red tape among managers and frontline staff relates to objectively measured performance. The data consists of survey responses from teachers and principals at Danish upper secondary schools combined with grade-level administrative performance data. Based on theories of red tape...... and motivation crowding, we hypothesize that perceived organizational red tape reduces performance within such organizations. The empirical result is a small, negative relationship between staff perception of red tape and performance, and no relationship between manager-perceived red tape and performance....

  11. Transaction aware tape-infrastructure monitoring

    International Nuclear Information System (INIS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-01-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  12. New endodontic obturation systems and their interfacial bond strength with intraradicular dentine - ex vivo studies.

    Science.gov (United States)

    Pawińska, M; Kierklo, A; Tokajuk, G; Sidun, J

    2011-01-01

    To comparatively evaluate adhesive properties of selected root canal fillings through the measurement of the material-dentine interfacial bond strength. Fifty extracted single-rooted human teeth with one canal each were prepared using Hero instruments to size 30.04. Teeth were divided into four subgroups depending on the root canal filling material and the method of obturation: Resilon/Epiphany - a thermoplastic method (IA), Resilon/Epiphany - a matching single-point method (IB), gutta-percha/Roeko Seal Automix - a thermoplastic method (IIA) and gutta-percha/Roeko Seal Automix - a matching single-point method (IIB). The obturated roots were cut perpendicular to the long axis to create 1.7 mm thick slices. The bond strength was measured for each test slice with push -out testing machine. The highest push-out bond strength was registered in subgroup IB (3.98 ± 1.33 MPa). Significantly lower bond strength was observed in subgroups IA (0.50 ± 0.24 MPa), IIA (0.33 ± 0.18 MPa) and IIB (0.08 ± 0.03 MPa) (pmaterial-dentine interfacial bond strength values were observed between IA and IIA, IA and IIB, IIA and IIB subgroups (p > 0.05). The push-out bond strength of the material-dentine interface was dependent on the type of material used and the root canal filling technique. The R/E system exhibited better adhesion ability to intraradicular dentine than G/RSA. The highest bond strength was observed for Resilon/Epiphany introduced with the single-cone technique.

  13. Speech evaluation with and without palatal obturator in patients submitted to maxillectomy Avaliação de fala com e sem obturador de palato em pacientes submetidos à maxilectomia

    Directory of Open Access Journals (Sweden)

    Viviane de Carvalho-Teles

    2006-12-01

    Full Text Available Most patients who have undergone resection of the maxillae due to benign or malignant tumors in the palatomaxillary region present with speech and swallowing disorders. Coupling of the oral and nasal cavities increases nasal resonance, resulting in hypernasality and unintelligible speech. Prosthodontic rehabilitation of maxillary resections with effective separation of the oral and nasal cavities can improve speech and esthetics, and assist the psychosocial adjustment of the patient as well.The objective of this study was to evaluate the efficacy of the palatal obturator prosthesis on speech intelligibility and resonance of 23 patients with age ranging from 18 to 83 years (Mean = 49.5 years, who had undergone inframedial-structural maxillectomy. The patients were requested to count from 1 to 20, to repeat 21 words and to spontaneously speak for 15 seconds, once with and again without the prosthesis, for tape recording purposes. The resonance and speech intelligibility were judged by 5 speech language pathologists from the tape recordings samples. The results have shown that the majority of patients (82.6% significantly improved their speech intelligibility, and 16 patients (69.9% exhibited a significant hypernasality reduction with the obturator in place. The results of this study indicated that maxillary obturator prosthesis was efficient to improve the speech intelligibility and resonance in patients who had undergone maxillectomy.A maioria dos pacientes submetidos a ressecções de maxila apresenta alterações nas funções de fala e de deglutição. O acoplamento das cavidades oral e nasal resulta em hipernasalidade de graus variados e no comprometimento da inteligibilidade de fala. A reabilitação protética tem como objetivo separar as cavidades oral e nasal podendo reduzir as alterações de ordem estética, funcional e ainda melhorar o ajustamento social deste paciente. Este trabalho teve como objetivo avaliar a eficácia da pr

  14. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  15. Inside Out: Organizations as Service Systems Equipped with Relational Boundaries

    Directory of Open Access Journals (Sweden)

    María Jimena Crespo Garrido

    2017-04-01

    Full Text Available Currently, literature on organizational boundaries is at the center of a heated debate, characterized by a shift from a transactional approach to a broader immaterial perspective centered on the concept of boundless organizations. However, the overestimation of the effects of contemporary dematerialization on business processes can lead to the progressive neglect of the existence of corporate borders. In light of this consideration, the present work aims at proposing a new type of criterion for defining organizational boundaries, halfway between the conception of the firm’s total openness and total closure. To this end, the authors envisage the use of a new interpretive logic defined as “relational”, resulting from the specification of the systemic view (and as the sum of the logic underlying the viable systems approach (VSA. This approach views the definition of boundaries. Therefore, in the large and intricate scenery of the studies dedicated to organizational boundaries, this work contributes to a better understanding of border selection as an interactive and changeable process capable of pushing organizations towards a greater awareness of their strategic dimension. This paper also offers some insights for future research, suggesting that both scholars and professionals investigate, firstly, new frontiers for the identification of organizational boundaries and, secondly, the possible positive repercussions that new organizational redesign modes could determine for a greater competitive success.

  16. Red nuggets grow inside-out: evidence from gravitational lensing

    NARCIS (Netherlands)

    Oldham, Lindsay; Auger, Matthew W.; Fassnacht, Christopher D.; Treu, Tommaso; Brewer, Brendon J.; Koopmans, L. V. E.; Lagattuta, David; Marshall, Philip; McKean, John; Vegetti, Simona

    We present a new sample of strong gravitational lens systems where both the foreground lenses and background sources are early-type galaxies. Using imaging from Hubble Space Telescope (HST)/Advanced Camera for Studies (ACS) and Keck/NIRC2, we model the surface brightness distributions and show that

  17. "Inside-out Pedagogy": Theorising Pedagogical Transformation through Teaching Philosophy

    Science.gov (United States)

    Scholl, Rosie

    2014-01-01

    This retrospective interview study focused on the impact that training and implementation of Philosophy, in Lipman's tradition of Philosophy for Children, had on the pedagogy of 14 primary teachers at one school. Semi-structured interviews were conducted to document the impact of teaching Philosophy on pedagogy, the resources required to…

  18. Learning/work: Turning work and lifelong learning inside out

    Science.gov (United States)

    Walters, Shirley; Cooper, Linda

    2011-08-01

    CONFINTEA VI took place against the background of an uneven and contradictory social and economic impact of globalisation. This impact registered globally and locally, in both the political North and South, drawing new lines of inequality between "core" and "periphery", between insiders and outsiders of contemporary society. Financial turmoil in the world has exacerbated levels of poverty and insecurity. The question is how work-related education and conceptions of learning might promote greater inclusion and security for those whose livelihoods are most severely affected by globalisation. The Belém Framework for Action implicitly recognises that lifelong learning and work cannot be discussed outside broader socio-economic and political contexts. The authors of this article draw substantially on research from around the world and argue for the re-insertion of "politics and power" into both the theory and practice of "lifelong learning" and "work".

  19. The neurobiology of the emotional adolescent: From the inside out

    Science.gov (United States)

    Guyer, Amanda E.; Silk, Jennifer S.; Nelson, Eric E.

    2016-01-01

    Adolescents are commonly portrayed as highly emotional, with their behaviors often hijacked by their emotions. Research on the neural substrates of adolescent affective behavior is beginning to paint a more nuanced picture of how neurodevelopmental changes in brain function influence affective behavior, and how these influences are modulated by external factors in the environment. Recent neurodevelopmental models suggest that the brain is designed to promote emotion regulation, learning, and affiliation across development, and that affective behavior reciprocally interacts with age-specific social demands and different social contexts. In this review, we discuss current findings on neurobiological mechanisms of adolescents’ affective behavior and highlight individual differences in and social-contextual influences on adolescents’ emotionality. Neurobiological mechanisms of affective processes related to anxiety and depression are also discussed as examples. As the field progresses, it will be critical to test new hypotheses generated from the foundational empirical and conceptual work and to focus on identifying more precisely how and when neural networks change in ways that promote or thwart adaptive affective behavior during adolescence. PMID:27506384

  20. Using Raspberry Pi to Teach Computing "Inside Out"

    Science.gov (United States)

    Jaokar, Ajit

    2013-01-01

    This article discusses the evolution of computing education in preparing for the next wave of computing. With the proliferation of mobile devices, most agree that we are living in a "post-PC" world. Using the Raspberry Pi computer platform, based in the UK, as an example, the author discusses computing education in a world where the…

  1. Microsoft® Office Excel® 2007 Inside Out

    CERN Document Server

    Dodge, Mark

    2009-01-01

    You're beyond the basics, so dive in and really put your spreadsheet skills to work! This supremely organized reference is packed with hundreds of timesaving solutions, troubleshooting tips, and workarounds. It's all muscle and no fluff. Discover how the experts tackle Excel 2007-and challenge yourself to new levels of mastery!Learn expert techniques for designing powerful spreadsheetsApply built-in functions-or write your own-and carry out complex calculationsUse rich charting capabilities and new SmartArt graphics to visually represent dataPerform sophisticated data analysis: financial, stat

  2. Microsoft® Office Access™ 2007 Inside Out

    CERN Document Server

    Viescas, John

    2009-01-01

    You're beyond the basics, so dive right in and really put your database skills to work! This supremely organized reference is packed with hundreds of timesaving solutions, troubleshooting tips, and workarounds. It's all muscle and no fluff. Discover how the experts tackle Access 2007-and challenge yourself to new levels of mastery! Create tables that support your database design strategyImport and link to data from spreadsheets, text files, databases, and other ODBC data sourcesBuild simple to complex queries to manipulate dataLearn advanced techniques for building and customizing user inter

  3. Inside Out: Modern Imaging Techniques to Reveal Animal Anatomy

    DEFF Research Database (Denmark)

    Lauridsen, Henrik; Hansen, Kasper; Wang, Tobias

    2011-01-01

    allow for creation of three-dimensional representations that can be of considerable value in the dissemination of anatomical studies. In this methodological review, we present our experiences using MRI, CT and mCT to create advanced representation of animal anatomy, including bones, inner organs...... and blood vessels in a variety of animals, including fish, amphibians, reptiles, mammals, and spiders. The images have a similar quality to most traditional anatomical drawings and are presented together with interactive movies of the anatomical structures, where the object can be viewed from different...

  4. Context Counts: Viewing Small School Leadership from the Inside out

    Science.gov (United States)

    Clarke, Simon; Wildy, Helen

    2004-01-01

    This paper proceeds from the basis that leadership can only be understood in context and by viewing it from the inside. In particular, it argues that the contextual complexity of small school leadership warrants attention from researchers, policy makers and system administrators and describes the nature of this complexity as depicted in the…

  5. Inside out: modern imaging techniques to reveal animal anatomy.

    OpenAIRE

    Henrik Lauridsen; Kasper Hansen; Tobias Wang; Peter Agger; Jonas L Andersen; Peter S Knudsen; Anne S Rasmussen; Lars Uhrenholt; Michael Pedersen

    2011-01-01

    Animal anatomy has traditionally relied on detailed dissections to produce anatomical illustrations, but modern imaging modalities, such as MRI and CT, now represent an enormous resource that allows for fast non-invasive visualizations of animal anatomy in living animals. These modalities also allow for creation of three-dimensional representations that can be of considerable value in the dissemination of anatomical studies. In this methodological review, we present our experiences using MRI,...

  6. Positioning the Brand 3.0 : An inside out approach

    NARCIS (Netherlands)

    Rik Riezebos; drs. Jaap van der Grinten

    2014-01-01

    Korean edition! Positioning is hot. Not only in the realm of consumer goods manufacturers, but also for other companies, institutions, governments and even individual persons. An explosion of good quality products on the market and targeted media and advertising campaigns has led to an increasing

  7. Positioning the Brand : An Inside-Out Approach

    NARCIS (Netherlands)

    drs. Jaap van der Grinten; Rik Riezebos

    2011-01-01

    Positioning is hot. Not only in the realm of consumer goods manufacturers, but also for other companies, institutions, governments and even individual persons. An explosion of good quality products on the market and targeted media and advertising campaigns has led to an increasing interest from

  8. Microsoft® Exchange Server 2010 Inside Out

    CERN Document Server

    Redmond, Tony

    2010-01-01

    Dive into Exchange Server 2010 and SP1-and discover how to really put your messaging solutions to work! This well-organized and in-depth reference packs all the details you need to deploy and manage Exchange 2010, including hundreds of timesaving solutions, expert tips, and workarounds.Topics include preparing for the deployment of Exchange 2010; new features of Service Pack 1; using Remote PowerShell and the Exchange Management Shell; understanding how the new Role Based Access Control (RBAC) permissions model works and how to customize it to your requirements; the new high availability mode

  9. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  10. Echoes from teacher discourse: an inside-out perspective Echoes from teacher discourse: an inside-out perspective

    Directory of Open Access Journals (Sweden)

    Adriana de Carvalho Kuerten Dellagnelo

    2008-04-01

    Full Text Available Researchers in teacher education have paid increasing attention to teacher reflectivity and its relevance for teaching/learning practices. However, to our knowledge, there has been no investigation of teacher reflectivity from the perspective of Systemic Functional Linguistics (SFL. In this paper we draw mainly on SFL to examine aspects of the relationship between teachers and learners as construed in self-evaluative reports written by 4 Brazilian teacher-trainees. These reports – self-reflections on the trainees’ own teaching practices – were collected as part of work developed in a Teaching Practicum Course taken by these trainees. In addition to SFL, in our discussion of results we also draw on research related to teacher education/reflectivity (e.g., Freeman & Johnson, 1998; Richards & Lockart, 1996. The linguistic structures described and interpreted in order to unravel the roles these trainees ascribe to themselves and their students reveal a selfcentered positioning of the trainees as social participants whose practices are shaped by conceptions traditionally established by a culture of schooling which maintains the emphasis of teaching on the transmission of knowledge. Results also reveal asymmetry between teachers and students inasmuch as the latter are construed as playing a secondary role, with little responsibility in the process of teaching/learning a foreign language. The study may contribute to enhance the search for awareness of contrasts between new views of language teaching/learning and traditional perceptions such as the ones conveyed in the reports analyzed. Researchers in teacher education have paid increasing attention to teacher reflectivity and its relevance for teaching/learning practices. However, to our knowledge, there has been no investigation of teacher reflectivity from the perspective of Systemic Functional Linguistics (SFL. In this paper we draw mainly on SFL to examine aspects of the relationship between teachers and learners as construed in self-evaluative reports written by 4 Brazilian teacher-trainees. These reports – self-reflections on the trainees’ own teaching practices – were collected as part of work developed in a Teaching Practicum Course taken by these trainees. In addition to SFL, in our discussion of results we also draw on research related to teacher education/reflectivity (e.g., Freeman & Johnson, 1998; Richards & Lockart, 1996. The linguistic structures described and interpreted in order to unravel the roles these trainees ascribe to themselves and their students reveal a selfcentered positioning of the trainees as social participants whose practices are shaped by conceptions traditionally established by a culture of schooling which maintains the emphasis of teaching on the transmission of knowledge. Results also reveal asymmetry between teachers and students inasmuch as the latter are construed as playing a secondary role, with little responsibility in the process of teaching/learning a foreign language. The study may contribute to enhance the search for awareness of contrasts between new views of language teaching/learning and traditional perceptions such as the ones conveyed in the reports analyzed.

  11. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  12. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  14. Obturator internus pyomyositis manifested as sciatica in a patient with subacute bacterial endocarditis: A rare case report.

    Science.gov (United States)

    Hsu, Wei-Ching; Hsu, Jin-Yi; Chen, Michael Yu-Chih; Liang, Chung-Chao

    2016-07-01

    Pyomyositis is a pyogenic infection of the skeletal muscles causing myalgia and fever in patients. Hematogenous seeding engendered by persistent bacteremia and septic embolism is usually the underlying cause of the disease. Trauma, intravenous drug use, and immunodeficiency are the main predisposing factors.Obturator internus pyomyositis with sciatica has not previously been reported. We report a rare case of a patient with subacute bacterial endocarditis presenting with left buttock pain and sciatica.Computed tomography confirmed the diagnosis of obturator internus pyomyositis. The patient was discharged uneventfully after successful antibiotic treatment.The mortality rate of patients who have pyomyositis comorbid with another condition or disease is extremely high. Early diagnosis and aggressive management are imperative.

  15. Efeitos do Kinesio Taping no Desporto

    OpenAIRE

    Pereira, Marcelo

    2012-01-01

    Trabalho apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciado em Fisioterapia O médico japonês, Dr. Kenzo Kase criou, em 1973, o kinesio taping, uma nova aplicação de ligadura adesiva, tendo como objectivo melhorar a função da musculatura, sem limitar os movimentos, reduzir a dor, edema e os espasmos musculares. Parece ter também a capacidade de prevenir lesões no desporto, sendo por isso uma técnica comummente utilizada para este efeito....

  16. StorageTek T10000 Tape Cartridge

    CERN Multimedia

    1985-01-01

    Oracle StorageTek T10000T2 cartridge has total capacity of 5 TB. It is actually manufactured by Fuji Film, uses Barium Ferrite (BaFe) particles technology data store, but is also equipped with RFID chip. There is over 1 km of tape inside of the cartridge with 3584 data tracks and it supports over 25000 load/unload cycles. The archival life is estimated to be around 30 years and uncorrected bit error rate is 10-19. CERN however usually migrates data to newer technologies roughly every 5 years in order to keep the footprint under control.

  17. Information retrieval system based on INIS tapes

    International Nuclear Information System (INIS)

    Pultorak, G.

    1976-01-01

    An information retrieval system based on the INIS computer tapes is described. It includes the three main elements of a computerized information system: a data base on a machine -readable medium, a collection of queries which represent the information needs from the data - base, and a set of programs by which the actual retrieval is done, according to the user's queries. The system is built for the center's computer, a CDC 3600, and its special features characterize, to a certain degree, the structure of the programs. (author)

  18. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  19. Effect of Instrument Design and Access Outlines on the Removal of Root Canal Obturation Materials in Oval-shaped Canals.

    Science.gov (United States)

    Niemi, Tuomas K; Marchesan, Melissa A; Lloyd, Adam; Seltzer, Robert J

    2016-10-01

    The aim of this study was to compare the effectiveness of TRUShape (TS) instruments with ProFile Vortex Blue (VB) instruments for the removal of obturation materials during retreatment of single-canal mandibular premolars performed through 2 access outlines. Initial root canal treatment was completed through a contracted endodontic cavity (CEC) design. Canals were instrumented to an F2 ProTaper instrument, obturated with warm lateral condensation of gutta-percha with AH Plus sealer, and allowed to set for 30 days at 37°C and 100% humidity. For retreatment, specimens were divided into 2 groups (n = 24) on the basis of access outline, CEC or traditional endodontic cavity (TEC). Retreatment was initiated by using ProTaper Retreatment instruments (D1-D3). Specimens were then stratified, further divided (n = 12), and reinstrumented up to TS 40 .06v or 40 .06 VB. Irrigation was performed by using 8.25% NaOCl and QMix 2in1. Retreatment time was recorded. Teeth were sectioned and photographed, and the percentage of remaining obturation materials was measured. Data were analyzed with Kruskal-Wallis analysis of variance for two-factor tests (α canal surface when compared with TEC-VB, CEC-TS, and TEC-TS (P ≤ .05). None of these other combinations were different from each other (P > .05). Significantly more time was required for retreatment with CEC-TS (27.68 ± 1.4 minutes) than the other groups (P root canal surface of mandibular premolars. However, in the presence of a CEC access design, using TS instruments removed more obturating material in single-rooted, oval-shaped canals. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Comparison of radiographic density and compaction index of root canal obturation using nickel titanium or stainless-steel spreaders

    Directory of Open Access Journals (Sweden)

    M. Adel

    2016-08-01

    Full Text Available Background: Both nickel titanium and stainless-steel spreaders are available. The obvious advantage of nickel titanium spreader over stainless steel spreaders is greater penetration in curved canals. Objective: To compare the radiographic density and compaction index of root canal obturation using nickel-titanium or stainless-steel spreaders in curved canals. Methods: In this experimental study the primary weight of 30 acrylic blocks with 45o degrees of apical curvature were measured by a scale (W1. After canals were prepared by step back master apical up to file #30 all blocks were weighed again (W2 and randomly divided in two groups of 15each. All canals were obturated by Cold lateral compaction technique (with nickel-titanium in one group and stainless-steel finger spreaders in another group. After all blocks were reweighed (W3, compaction index (W3-W2/W1-W2 was calculated. One radiograph was taken for each sample. Apical density of the apical third of each canal was measured by digital transmission densitometer. Data were analyzed statistically using T-test. Findings: Mean compaction index for nickel-titanium group was 7.67±2.38 and for stainless-steel group was 9.14±4.06. There was no significant difference between two groups. Mean radiographic density of obturation was 2.05±0.14 in nickel-titanium group and was 2.07±0.21 in stainless-steel group. There was no significant difference between two groups. Conclusion: It is concluded that nickel-titanium spreaders are not superior than stainless-steel spreaders in obturating curved canal.

  1. Methods of Measuring Stress Relaxation in Composite Tape Springs

    Science.gov (United States)

    2015-03-26

    10 3. Cure Cycle Recommended for Patz F7 Prepreg . . . . . . . . . . . . . . . . . . . . . 17 4. Typical Stress...unique and dimensionally complex parts. Hand lay-up is the method by which prepreg tape or fibers are laid down and then the matrix is then ‘painted’ on...structure. Hand lay-up using a prepreg tape stands out as the inexpensive choice for the unique low number production of tape springs and should

  2. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    Science.gov (United States)

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  3. Penetrating Obturator Artery Injury after Gunshot Wounds: A Successful Multidisciplinary Trauma Team Approach to a Potentially Lethal Injury.

    Science.gov (United States)

    Maraqa, Tareq I; Shin, Ji-Sun J; Diallo, Ismael; Sachwani-Daswani, Gul R; Mercer, Leo C

    2017-11-17

    Obturator artery injury (OAI) from pelvic gunshot wounds (GSW) is a rarely reported condition. Hemorrhages from pelvic trauma (PT) are mostly venous. Arterial hemorrhages represent about 10-20% of PTs. When arterial hemorrhages from PT occur, they are a severe and deadly complication often causing significant hemodynamic instability and eventual shock. A  23-year-old male presented to our emergency service via a private vehicle with multiple gunshot wounds to both thighs and to the lower back, resulted in rectal and obturator artery (OA) injuries. The patient underwent a successful coil-embolization of the right OA. Given the density of structures within the pelvis, patients who sustain gunshot wounds to the pelvic region are at high risk for injury to the small bowel, sigmoid colon, rectum, bladder, and/or vascular structures. While bleeding is the major cause of early mortality in PT, rectal injuries carry the highest mortality due to visceral injuries. A high clinical index of suspicion is needed to diagnose an iliac artery injury or injury to its branches. Prompt computed tomographic angiogram (CTA) and embolization of the OA is the best method to control and stop the bleeding and improve the mortality outcome. Clinicians caring for patients presenting with pelvic gunshot wounds should pay attention to the delayed presentation of internal hemorrhage from the OAs. A multidisciplinary team approach is crucial in the successful management of penetrating injuries to the obturator artery.

  4. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  5. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  6. Molten carbonate fuel cell integral matrix tape and bubble barrier

    International Nuclear Information System (INIS)

    Reiser, C.A.; Maricle, D.L.

    1983-01-01

    A molten carbonate fuel cell matrix material is described made up of a matrix tape portion and a bubble barrier portion. The matrix tape portion comprises particles inert to molten carbonate electrolyte, ceramic particles and a polymeric binder, the matrix tape being flexible, pliable and having rubber-like compliance at room temperature. The bubble barrier is a solid material having fine porosity preferably being bonded to the matrix tape. In operation in a fuel cell, the polymer binder burns off leaving the matrix and bubble barrier providing superior sealing, stability and performance properties to the fuel cell stack

  7. Nonlinear Model of Tape Wound Core Transformers

    Directory of Open Access Journals (Sweden)

    A. Vahedi

    2015-03-01

    Full Text Available Recently, tape wound cores due to their excellent magnetic properties, are widely used in different types of transformers. Performance prediction of these transformers needs an accurate model with ability to determine flux distribution within the core and magnetic loss. Spiral structure of tape wound cores affects the flux distribution and always cause complication of analysis. In this paper, a model based on reluctance networks method is presented for analysis of magnetic flux in wound cores. Using this model, distribution of longitudinal and transverse fluxes within the core can be determined. To consider the nonlinearity of the core, a dynamic hysteresis model is included in the presented model. Having flux density in different points of the core, magnetic losses can be calculated. To evaluate the validity of the model, results are compared with 2-D FEM simulations. In addition, a transformer designed for series-resonant converter and simulation results are compared with experimental measurements. Comparisons show accuracy of the model besides simplicity and fast convergence

  8. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  9. Obturator internus muscle autotransfer: a new concept for the treatment of anismus. Clinical experience.

    Science.gov (United States)

    Farag, A

    1997-01-01

    In this study 20 patients suffering from chronic constipation due to spastic anal sphincters were operated upon using a new surgical technique. The technique aimed at constructing an active anal dilator mechanism using the obturator internus muscles mobilized from both sides and sutured to the side wall of the anal canal in order to overcome the spastic anal sphincters during defaecation. This series included 3 failures (15%), 16 successful cases (80%), and 1 dissatisfied patient despite normal postoperative investigations (5%). Eleven patients (55%) showed immediate postoperative normalization of their defaecation. Five patients (25%) showed normalization of their defaecation after 10 sessions of electric stimulation of the transposed muscles given 1 month postoperatively for 10 successive days. All the successful cases (16 patients) maintained their good results during the period of follow-up which ranged from 16 to 45 months (average = 30.31 months). For the successful cases, follow-up was from 16 to 42 months (average = 26.72 months). Immediate postoperative complications included 3 cases of wound infection and 2 cases of transient incontinence to gases which responded completely to postoperative Faradic stimulation. No cases of persistent incontinence of any degree were detected among the 20 patients studied. The 3 failures were mainly due to avoidable technical problems. The technique was safe, easy, and physiological, using a strictly perineal approach.

  10. Pembuatan Obturator Mata pada Pasien dengan Kehilangan Mata Akibat Cacat Bawaan

    Directory of Open Access Journals (Sweden)

    Clara Rosalina

    2010-06-01

    Full Text Available Kasus kehilangan mata pada pasien dapat menimbulkan masalah fungsi dan estetik. Salah satu cara yang dapat dilakukan untuk memperbaiki masalah estetik adalah dengan membuatkan protesa mata kepada pasien tersebut. Tujuan pembuatan obturator mata pada pasien yang kehilangan mata adalah untuk membantu pasien dalam memperbaiki estetik. Pasien wan ita usia 35 tahun datang ke klinik Prostodonsia RSGM FKG UGM dengan kondisi kehilangan mata sebelah kanan yang merupakan cacat bawaan. Pemeriksaan wajah menunjukkan muka asimetris. Pada mata kanan tampak adanya cheloid yang timbul setelah operasi pengangkatan bola mata. Perawatan dilakukan dengan pembuatan protesa mata non fabricated dengan tahap-tahap: pencetakan mata dengan sendok cetak mata perorangan dan pengisian hasil cetakan terdiri dari dua bagian, yang pertama diisi dengan gips keras sampai bagian terlebar dari cetakan dasar soket dan dibuat tiga retensi sebagai kunci, kedua sampai menutupi seluruh hasil cetakan. Pembuatan model malam sklera, mencoba pola malam sklera dan packing model malam sklera. Oef/asking dan polishing untuk membuat sklera akrilik, mencoba sklera akrilik dan penentuan lokasi diameter iris, melukis iris dan pupil, penyelesaian protesa mata, packing sklera dan iris, def/asking dan polishing untuk membuat protesa mata serta insersi protesa mata. Kontrol setelah 2 minggu menunjukkan hasil yang baik, tidak ada keluhan rasa sakit, tidak ada peradangan, volume dan frekuensi air mata menjadi berkurang jumlah dan frekuensinya.

  11. A novel digital workflow to manufacture personalized three-dimensional-printed hollow surgical obturators after maxillectomy.

    Science.gov (United States)

    Kortes, J; Dehnad, H; Kotte, A N T; Fennis, W M M; Rosenberg, A J W P

    2018-04-07

    Partial or complete resection of the maxilla during tumour surgery causes oronasal defects, leading to oral-maxillofacial dysfunction, for which the surgical obturator (SO) is an important treatment option. Traditional manufacturing of SOs is complex, time-consuming, and often results in inadequate fit and function. This technical note describes a novel digital workflow to design and manufacture a three-dimensional (3D)-printed hollow SO. Registered computed tomography and magnetic resonance imaging images are used for gross tumour delineation. The produced RTStruct set is exported as a stereolitography (STL) file and merged with a 3D model of the dental status. Based on these merged files, a personalized and hollow digital SO design is created, and 3D printed. Due to the proper fit of the prefabricated SO, a soft silicone lining material can be used during surgery to adapt the prosthesis to the oronasal defect, instead of putty materials that are not suitable for this purpose. An STL file of this final SO is created during surgery, based on a scan of the relined SO. The digital workflow results in a SO weight reduction, an increased fit, an up-to-date digital SO copy, and overall easier clinical handling. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Sputtered thin films for high density tape recording

    NARCIS (Netherlands)

    Nguyen, L.T.

    This thesis describes the investigation of sputtered thin film media for high density tape recording. As discussed in Chapter 1, to meet the tremendous demand of data storage, the density of recording tape has to be increased continuously. For further increasing the bit density the key factors are:

  13. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  14. Recovery of recordings from heat damaged magnetic tapes

    Science.gov (United States)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  15. Ring shaped laser for tape winding of an endless tube

    NARCIS (Netherlands)

    Leonardus, Lucky

    2012-01-01

    AFPT is a start-up company that provides laser-assisted technology for the production of a pressurized component such as tube, pressure vessel, etc made from or strengthened by fiber reinforced plastic (FRP) tape. The tape is laid precisely by a machine head (connected to a robot), melted with a

  16. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  17. Multilayer tape cast SOFC – Effect of anode sintering temperature

    DEFF Research Database (Denmark)

    Hauch, Anne; Birkl, Christoph; Brodersen, Karen

    2012-01-01

    Multilayer tape casting (MTC) is considered a promising, cost-efficient, up-scalable shaping process for production of planar anode supported solid oxide fuel cells (SOFC). Multilayer tape casting of the three layers comprising the half cell (anode support/active anode/electrolyte) can potentially...

  18. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  19. Study on niobium carbide dispersed superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wada, H; Tachikawa, K [National Research Inst. for Metals, Tokyo (Japan); Oh' asa, M [Science Univ. of Tokyo (Japan)

    1977-11-01

    Niobium carbide (NbC) dispersed superconducting tapes have been fabricated by two metallurgical processes. In the first process, Ni-Nb-C alloys are directly arc melted and hot worked in air and the NbC phase is distributed in the form of fine discrete particles. In the second process, Ni-Nb and Ni-Nb-Cu alloys are arc melted, hot worked and subjected to solid-state carburization. NbC then precipitates along the grain boundaries, forming a network. The highest superconducting transition temperature attained is about 11 K. Taken together with the lattice parameter measurement, this indicates that NbC with a nearly perfect NaCl structure is formed in both processes. Measured values of the upper critical field, the critical current density and the volume fraction of the NbC phase are also discussed.

  20. Kinesio taping in patients with lateral epicondylitis.

    Science.gov (United States)

    Dilek, Banu; Batmaz, Ibrahim; Sarıyıldız, Mustafa Akif; Sahin, Ebru; Ilter, Leman; Gulbahar, Selmin; Cevik, Remzi; Nas, Kemal

    2016-11-21

    Lateral epicondylitis (LE) is a painful condition that affects the tendinous tissue of the lateral epicondyle of the humerus and leads to loss of function of the affected limb. Therefore it can have a major impact on the patient's social and personal life. Many treatments are recommended for lateral epicondylitis; unfortunately the evidence is limited. The aim of study was to investigate the effect of kinesio taping (KT) on pain, grip strength and function in patients LE. Thirty-one (23 females, 8 males) patients with LE were included. KT was applied twice a week for 2 weeks. Pain at rest, activity of daily living (ADL), night and palpation on lateral epicondyle was evaluated with the visual analog scale (VAS 0-10 cm), and the grip strength was measured with a hand held dynamometer. The stage of the disease was evaluated by the Nirschl score and the functional status was assessed with Patient-Rated Forearm Evaluation Questionnaire (PRTEQ) score. These parameters were evaluated before, at 2 weeks and 6 weeks after treatment. Patients' satisfaction was also recorded on a Likert scale after treatment at 2 weeks and 6 weeks. The average age of the patients was 43.58 ± 9.02. The dominant limb was affected in 64.5% (20) of the patients. After the application of KT on lateral epicondyle, there was a significant improvement in all parameters in terms of pain, Nirschl score, hand grip strength, patient satisfaction, and PRTEQ scores at 2 and 6 weeks. Kinesio taping can be an effective treatment method in LE. This application improves pain, grip strength and functional status of the patients with LE.

  1. New surgical technique for treatment of stress urinary incontinence TVT-ABBREVO from development to clinical experience.

    Science.gov (United States)

    Waltregny, David; de Leval, Jean

    2012-12-01

    Tension-free suburethral tapes have revolutionized the surgical treatment of female stress urinary incontinence (SUI). These tapes are inserted by way of a retropubic or transobturator route. The inside-out tension-free vaginal tape transobturator approach, or TVT-Obturator system (TVT-O, Ethicon Women's Health and Urology, Somerville, NJ), was developed ten years ago with the aim of minimizing the risk of urinary tract injuries associated with retropubic and outside-in transobturator tapes while reproducibly ensuring minimal tissue dissection. Cadaveric studies have shown that the anatomical trajectory of the TVT-O tape is strictly perineal and courses away from neighboring obturator and pudendal neurovascular structures. Several meta-analyses have shown similar SUI cure rates after retropubic and transobturator tape procedures. Yet, the transobturator route may be associated with less voiding dysfunction, blood loss, bladder perforation, and shorter operating time. The original TVT-O procedure was modified with the aim of reducing the incidence of postoperative groin pain as well as the rather theoretical risk of obturator nerve injury. This modified procedure, named TVT-ABBREVO (Ethicon Women's Health and Urology, Somerville, NJ), utilizes a shortened, 12-cm-long polypropylene tape. In addition, perforation of the obturator membrane with the scissors and guide is avoided in order to reduce the depth of lateral dissection, and consequently, to maximize securing of the tape within the obturator muscular/aponeurotic structures. In a comparative anatomical study, it was indeed observed that the shorter tape traversed less muscular structures (with no or only a minimal amount of tape lying in the adductor muscles) than its original counterpart, while still consistently anchoring in the obturator membrane at a similarly safe distance from the obturator canal. In a single-center randomized clinical trial, after a 3-year minimum follow-up, the modified TVT-O procedure

  2. Efficacy of ProTaper Retreatment System in Root Canals Obturated with Gutta-Percha Using Two Different Sealers and GuttaFlow

    Science.gov (United States)

    Siotia, Jaya; Acharya, Shashi Rashmi; Gupta, Sunil Kumar

    2011-01-01

    Objective. To compare the efficacy of ProTaper retreatment files in removing three different obturating materials. Study Design. Forty-five human, single-rooted premolars were divided into three experimental groups. Group 1 was obturated with gutta-percha and AH Plus sealer, Group 2 was obturated with gutta-percha and zinc oxide eugenol sealer, and Group 3 was obturated with GuttaFlow. Retreatment was done using the ProTaper universal rotary retreatment files. Root halves were visualized using magnifying loops at 3X magnification and optical stereomicroscope at 10X magnification. Images were analyzed using AutoCAD 2004 software to calculate area of the remaining debris in the canal. For statistical analysis were used variance test and ANOVA. Results. Total debris/canal area ratio between the three groups showed a statistically significant difference (P < 0.001). Conclusion. ProTaper retreatment system did not produce completely clean canals in any of the groups. However, it had the best efficacy towards removing silicon based obturating material GuttaFlow. PMID:22114598

  3. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  4. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  5. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  6. Cone Beam Computed Tomography Evaluation of the Periapical Status of Nonvital Tooth with Open Apex Obturated with Mineral Trioxide Aggregate: A Case Report

    Directory of Open Access Journals (Sweden)

    Vijay Shekhar

    2013-01-01

    Full Text Available Management of a tooth with open apex is a challenge to the dental practitioners. Evaluation of the periapical healing is required in such cases by radiographic techniques. The objective of this paper was to assess the healing of a periapical lesion in a non-vital tooth with open apex treated with mineral trioxide aggregate (MTA obturation using cone beam computed tomography (CBCT. The endodontic treatment of a fractured non-vital discolored maxillary left lateral incisor with an open apex was done with MTA obturation. The clinical and radiographic followup done regularly showed that the tooth was clinically asymptomatic and that the size of the periapical lesion observed by intraoral periapical (IOPA radiographs and CBCT was decreased remarkably after two years. CBCT and IOPA radiographs were found to be useful radiographic tools to assess the healing of a large periapical lesion in a non-vital tooth with open apex managed by MTA obturation.

  7. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    Science.gov (United States)

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  8. [IMPROVEMENT AND CHOICE OF COLOSTOMY METHOD IN THE TREATMENT OF PATIENTS, SUFFERING AN ACUTE OBTURATIVE IMPASSABILITY OF LARGE BOWEL].

    Science.gov (United States)

    Kustryo, V I; Langazo, O V

    2015-11-01

    Colostomy was done in 49 patients, suffering an acute obturative impassability of large bowel (AOILB). In 28 patients (1st group) colostomy was conducted in accordance to standard method; in 21 (2nd group)--in accordance to the method, proposed by us. Application of the method proposed for surgical treatment of AOILB have guaranteed a reduction of postoperative paracolostomal complications rate in 6.8 times, of postoperative lethality--in 2.2 times, duration of the patient stationary treatment--in 1.4 times, the rate of dressings and the dressing material expanses--in 10 times.

  9. Engineering Critical Current Density Improvement in Ag- Bi-2223 Tapes

    DEFF Research Database (Denmark)

    Wang, W. G.; Seifi, Behrouz; Eriksen, Morten

    2000-01-01

    Ag alloy sheathed Bi-2223 multifilament tapes were produced by the powder-in-tube method. Engineering critical current density improvement has been achieved through both enhancement of critical current density by control of the thermal behavior of oxide powder and by an increase of the filling...... factor of the tapes. Phase evolution at initial sintering stage has been studied by a quench experiment in Ag-Bi-2223 tapes. The content, texture, and microstructure of various phases were determined by XRD and SEM. A novel process approach has been invented in which square wire was chosen rather than...

  10. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  11. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  12. Shuttle-Data-Tape XML Translator

    Science.gov (United States)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  13. How to make sticky tapes stickier

    Science.gov (United States)

    Ponson, Laurent; Xia, Shuman; Ravichandran, Guruswami; Bhattacharya, Kaushik; California Institute of Technology Team

    2011-03-01

    Thin film adhesives have become increasingly important in various applications such as packaging and coating, and we benefit daily of their adhesion properties by using various kinds of tapes. Despite the apparent simplicity of these systems, a certain number of questions remain open. In particular, important efforts have been deployed recently to understand the effect of the complex tridimensional and highly heterogeneous structure at the interface of some adhesives, such as the one encountered in nature like the geckos toes. Although inspired by these natural adhesives, we studied a much simpler system, and however largely unexplored: a thin film with spatially varying adhesion energy and elastic properties. We will show how these heterogeneities introduced at the microscale can generate quite unexpected macroscopic behaviors, and that one can this way design stronger adhesives with new properties. Beyond their practical interests, these systems involve long range elastic interactions and heterogeneities resulting in a rich and complex physics that will be illustrated through experimental examples and their theoretical interpretation.

  14. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  15. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  16. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  17. ICI optical data storage tape: An archival mass storage media

    Science.gov (United States)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  18. Taping reduces pain and disability in patients with knee osteoarthritis.

    NARCIS (Netherlands)

    Ende, E. van den

    2004-01-01

    Question: Is taping of the knee effective in improving pain and disability in patients with osteoarthritis of the knee? Design Randomised controlled trial. Setting University and private practices in Melbourne, Australia. Patients: Volunteers who responded to advertisements in local newspapers.

  19. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  20. DICOM implementation on online tape library storage system

    Science.gov (United States)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  1. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    Science.gov (United States)

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  2. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    Directory of Open Access Journals (Sweden)

    Ahmed Alkahtani

    2013-01-01

    Full Text Available The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  3. Tape measure to aid prescription in paediatric resuscitation.

    OpenAIRE

    Hughes, G; Spoudeas, H; Kovar, I Z; Millington, H T

    1990-01-01

    A tape measure, based on 50th centile weight for height and designed to permit easy drug dosage calculation, endotracheal tube size and DC cardioversion current dosages in childrens' emergencies, was tested for reliability by medical and nursing staff with varying paediatric experience. We found that the tape measure gave a reproducible estimate of weight and suggest that its use would facilitate decision making by inexperienced medical and nursing staff in paediatric resuscitation when there...

  4. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  5. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  6. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  7. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. TVT-Secur (Hammock) versus TVT-Obturator: a randomized trial of suburethral sling operative procedures.

    Science.gov (United States)

    Hota, Lekha S; Hanaway, Katherine; Hacker, Michele R; Disciullo, Anthony; Elkadry, Eman; Dramitinos, Patricia; Shapiro, Alexander; Ferzandi, Tanaz; Rosenblatt, Peter L

    2012-01-01

    This study aimed to compare TVT-Secur (TVT-S) and TVT-Obturator (TVT-O) suburethral slings for treatment of stress urinary incontinence (SUI). This was a single-center, nonblinded, randomized trial of women with SUI who were randomized to TVT-S or TVT-O from May 2007 to April 2009. The primary outcome, SUI on cough stress test (CST), and quality-of-life and symptom questionnaires (Pelvic Floor Distress Inventory [PFDI-20] and Pelvic Floor Impact Questionnaire [PFIQ-7]) were assessed at 12 weeks and 1 year. Forty-three women were randomized to TVT-S and 44 to TVT-O. There were no differences in median baseline PFDI-20 and PFIQ-7. Twenty-two (52.4%) of 42 participants randomized to TVT-S had a positive CST result at evaluation after 12 weeks or 1 year, whereas 4 (9.1%) of the 44 in the TVT-O group had a positive CST result. The intent-to-treat analysis showed that the risk of a positive CST result was 6 times higher after TVT-S than TVT-O (risk ratio, 6.0; 95% confidence interval [CI], 2.3-16.0). Among women not lost to follow-up, the risk ratio for a positive CST result after TVT-S compared with TVT-O was 17.9 (95% CI, 2.5-128.0) at 12 weeks and 3.5 (95% CI, 1.1-11.0) at 1 year. Both TVT-S and TVT-O resulted in improved quality of life and symptoms at 12 weeks. There was no difference between the groups for PFDI-20 (P = 0.40) or PFIQ-7 (P = 0.43). A similar pattern was seen at 1 year (P = 0.85 and P = 0.36). The TVT-S seems to have a higher risk of positive postoperative CST result; however, the procedures result in similar improvements in quality of life and symptoms.

  9. Forensic Pollen Evidence from Clothes by the Tape Adhesive Method

    Directory of Open Access Journals (Sweden)

    Chun-Liang Wu

    2006-06-01

    Full Text Available Collection and identification of pollen is becoming important in forensic applications. Many criminal cases have been reported to link suspects to the crime scene by analysis of pollen. Several methods have been used in the pollen collection and analysis, but they are expensive and tedious. Therefore, it is important to develop a simple method to collect pollen grains from clothes. We tried to recover pollen from clothing surface by using the sticky tapes method. The tape adhesive method has been widely used for sample collection for various purposes, but the efficiency of recovery of invisible pollen from clothes has rarely been reported. Therefore, to test the efficiency of the tape adhesive method in recovering pollen from clothes is important. The first author wore clothes that were made from textile S made by the mixture of cotton 60% and polyester fiber 40% to collect pollen from 26 different areas mostly in the northern part of Taiwan and then used cellophane tape D (Sirchie Finger Print Lab., Inc-No. 131LT4 to recover them from different body parts. Twenty-six pollen taxa were detected in different parts of clothes depending upon what kind of plant the first author stayed near. From the results, we concluded that the tape adhesive method is suitable in recovering pollen from clothes. We have suggested that the tape adhesive method could be part of methods for collecting pollen from clothes of suspects. It is simpler, faster and less expensive than other methods.

  10. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  11. Development of YBCO tape conductor fabrication technology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, G W; Kim, C J; Lee, H G. and others

    2001-08-01

    Superconductor when fabricated into wire shape is applied for developing electric power transmission cable, transformer, generator and SMES. Such superconducting power devices are capable of maximizing the efficiency of electricity and are anticipated to contribute for solving the energy problem of humankind. Furthermore the high temperature oxide superconductor developed in late 1980s is superconducting above boiling temperature of liquid nitrogen temperature has strong potential to realize superconducting power device and a lot of researches are being done in this field. Superconducting wire is the most important core material for developing superconducting power device and thermo-mechanical powder in tube process was developed to fabricated Ag/Bi-2223 conductor in long length having high critical current carrying capacity. Several companies fabricate and sell Ag/Bi-2223 superconducting wire longer than km length and used for developed electrical power device. But because of its inherent property of sharp decrease in current carrying capacity when applying high magnetic field, the application of Bi-2223 sire is limited as low as 20 K when the power device is in operating under high magnetic field. The YBCO tape conductor has the advantages of maintaining high critical current applying high magnetic field and can be used to most of the power device without special limitation. The metal substrate having good crystallographic texture and deposition technique which can deposit the good quality superconducting thin film continuously in large area are need to fabricate coated conductor, and this technique can be applied to develop the superconducting current limiter or magnetic field shielding device. A superconducting wire for using in high magnetic field is play a critical role in developing maglev, MRI, SMES, transformer, generator and motor and the continuous film deposition technique can be applied in other industry very much.

  12. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  13. A new method of measurement of tension on a moving magnetic tape

    Science.gov (United States)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  14. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  15. Obituary: Gerald Frederick Tape, 1915-2005

    Science.gov (United States)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  16. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  17. Aesthetic rehabilitation of a patient with an anterior maxillectomy defect, using an innovative single-step, single unit, plastic-based hollow obturator

    Directory of Open Access Journals (Sweden)

    Vishwas Bhatia

    2015-06-01

    Full Text Available What could be better than improving the comfort and quality of life of a patient with a life-threatening disease? Maxillectomy, the partial or total removal of the maxilla in patients suffering from benign or malignant neoplasms, creates a challenging defect for the maxillofacial prosthodontist when attempting to provide an effective obturator. Although previous methods have been described for rehabilitation of such patients, our goal should be to devise one stage techniques that will allow the patient an improved quality of life as soon as possible. The present report describes the aesthetic rehabilitation of a maxillectomy patient by use of a hollow obturator. The obturator is fabricated through a processing technique which is a variation of other well-known techniques, consisting of the use of a single-step flasking procedure to fabricate a single-unit hollow obturator using the lost salt technique. As our aim is to aesthetically and functionally rehabilitate the patient as soon as possible, the present method of restoring the maxillectomy defect is cost-effective, time-saving and beneficial for the patient.

  18. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Llopis, Eva; Schwartz, Richard B.; Bencardino, Jenny T.

    2009-01-01

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  19. Evaluation of the muscle morphology of the obturator externus and piriformis as the predictors of avascular necrosis of the femoral head in acetabular fractures.

    Science.gov (United States)

    Maini, Lalit; Kumar, Santosh; Batra, Sahil; Gupta, Rajat; Arora, Sumit

    2016-08-01

    Avascular necrosis (AVN) of femoral head is a recognised complication of fracture dislocation of the hip joint but is not studied frequently in relation to acetabulum fractures. The aim was to establish the relationship between obturator externus and piriformis muscle morphology in acetabulum fractures and potenital development of AVN of the femoral head. Twenty-five fractures were included in this prospective study and were subjected to radiological assessment and computed tomography of the pelvis. Magnetic resonance imaging (MRI) of the hip was performed to assess the morphology of obturator externus and piriformis, and findings were compared intraoperatively (in 15 cases). Serial radiographs were taken at monthly intervals to assess the development of avascular necrosis. The patients with no evidence of AVN on radiographs at 6 months had additional MRI scans to look for such changes. Three patients developed AVN of femoral head and two had complete tears of piriformis and/or obturator externus muscles on the pre-operative MRI with the findings confirmed intraoperatively (p = 0.013). None of the patients without changes of AVN at 6-month follow-up had complete tears of either or both muscles. Of these patients, there was one case each of T-type fracture, isolated posterior wall fracture with hip dislocation, and posterior wall with transverse fracture of the acetabulum. Complete tears of obturator externus and/or piriformis muscles are a strong predictor of future development of AVN of the femoral head.

  20. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara [Corades, S.L., Majadahonda-Madrid (Spain); Massachusetts General Hospital, Division of Musculoksleletal Radiology, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Alzira (Valencia) (Spain); Schwartz, Richard B. [Longwood MRI Specialists, Brookline, MA (United States); Bencardino, Jenny T. [NYU Department of Radiology, New York, NY (United States)

    2009-11-15

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  1. Red Tape dan Perilaku Masyarakat dalam Pelayanan Izin Usaha Perdagangan di Kota Makassar

    OpenAIRE

    Lukman, Lukman

    2015-01-01

    : Red tape as pathology has long been the focus of an expert study of bureaucracy. Early scholarly attempts conceptualized red tape at the individual level as in Merton's classic thesis (1940) about goal displacement. Waldo (1946) one man's red tape is another man's system. Kaufman (1977) one person's red tape may be another's treasured safeguard. Osborne and Gaebler (1992) good people trapped in bad systems. Bozeman and Feneey (2011) red tape is often used as a synonym of the term procedures...

  2. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  3. Prevalence of and factors affecting post-obturation pain following single visit root canal treatment in Indian population: A prospective, randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Syed Gufran Ali

    2012-01-01

    Full Text Available Aim: This prospective randomized clinical study (1 investigated the prevalence of post-obturation pain after single visit root canal treatment and (2 evaluated the influence of factors affecting the pain experience. Materials and Methods: One thousand three hundred and twenty eight (1328 patients were included in this study. Conventional single visit root canal treatment was carried out. The chemicomechanical preparation of root canals was done by a rotary protaper system with a combination of hand instruments. Post-operative pain was recorded by each patient by using visual analogue scale in well-defined categories at three time intervals, 12 h, 24 h, and 48 h. The data were analyzed using Fisher′s exact test. Results: The prevalence of post-obturation pain (severe within 48 h after treatment was 4% ( n = 54 but less as compared to the pain experienced after 12 h (9% and 24 h (8.6%. The factors that significantly influenced post-obturation pain experience were: Age (Fishers exact test = 46.387, P = 0.0, gender (Fishers exact test = 23.730, P = 0.0, arch (Fishers exact test = 11.710, P = 0.001, and presence of pre-operative pain (Fishers exact test = 67.456, P = 0.0. Conclusion: The presence of post-operative pain was low (4%. The important prognostic determinants of post-obturation pain were: Old age, female, mandibular teeth, and presence of pre-operative pain. The vital condition of the tooth does not affect the intensity and frequency of post-obturation pain.

  4. Effects of ultrasound therapy with taping PNF training and PNF training with taping in treatment and rehabilitation of sports injuries of high ankle sprain

    Directory of Open Access Journals (Sweden)

    D L Charly Daniel

    2017-01-01

    Conclusions: It was concluded that combining ultrasound with taping and PNF training with taping were found to be more beneficial in the treatment and rehabilitation of high ankle sprain injury. The combined effect of UT, PNF training, and taping may be explored by future researchers.

  5. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis.

    Science.gov (United States)

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis; Torres-Lagares, Daniel

    2017-08-01

    Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the "Virgen del Rocío" University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation. The POP has a greater use, as long as the defect in the

  6. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain

    Directory of Open Access Journals (Sweden)

    Chye CL

    2015-03-01

    Full Text Available Cien-Leong Chye,1 Cheng-Loong Liang,1 Kang Lu,1 Ya-Wen Chen,2,3 Po-Chou Liliang1 1Department of Neurosurgery, E-Da Hospital, I-Shou University, 2Department of Nursing, I-Shou University, 3School of Nursing, Kaohsiung Medical University, Kaohsiung, Taiwan Purpose: Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain.Patients and methods: Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS, Oxford hip scores (OHS, and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment.Results: At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement.Conclusion: When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning. Keywords: pulsed radiofrequency, obturator and femoral nerves, hip joint pain, osteoar­thritis

  7. Comparison of Tension-free Vaginal Tape Versus Transobturator Tape in Women with Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Zinat Ghanbari

    2007-06-01

    Full Text Available Objective: This study compared the Tension-free vaginal tape (TVT and Transobturator tape (TOT procedures for surgical treatment of stress urinary incontinence in women.Materials and methods: This prospective non randomized clinical trial was conducted in Vali-e-asr hospital from March 2001 to March 2005. A total of 71 patients with clinical and urodynamic diagnosis of Stress urinary incontinence (SUI were enrolled in the study. Patients were divided into two groups and underwent TVT or TOT procedures. Mean operation time, cure rate, post operative urinary retention, bleeding and infection were compared between two groups. SPSS software was used for statistical analysis. Chi square and fisher exact test calculated the effects of the nominal variables. Mean difference of quantitative variables were compared by student's T- test. P ≤0.05 was considered statistically significant. Results: There was no significant difference in mean time of operation and peri-operative complications among groups. Urinary retention was 13.8% (n=5 in the TVT group versus 2.8% (n=1 in TOT group (NS. The rates of cure (91.6% vs 91.4%, improvement (5.6% vs 8.6% and failure (2.8% vs 0 were similar for the TVT and TOT groups. The rate of hemorrhagic complications was 5.5% in TVT and 2.8% in TOT group (NS.Conclusion: TOT appears to be equally efficient to TVT for surgical treatment of stress urinary incontinence after 30 months follow-up.

  8. Three-dimensional modelling of metal evaporated tape

    International Nuclear Information System (INIS)

    Kay, G.E.

    1999-06-01

    As developments in magnetic recording increase, the demands for high density recording media continue to rise. One particular medium developed towards meeting these needs is the commercially successful metal evaporated (ME) tape. To provide a deeper understanding of the magnetic processes occurring in recording media, theoretical studies are carried out to complement experimental observations. Therefore, this thesis is concerned with developing a micromagnetic model to simulate the magnetic behaviour of ME tape. ME tape consists of bundles of granular columns which are tilted towards the film normal. The morphology of the film influences the magnetic behaviour and a 3D model is developed in this thesis to represent the columnar structure and the granular nature of ME tape. A Monte Carlo algorithm, consisting of a 'move and grow' procedure, is developed to generate an irregular system of spherical grains whose radii were generated from a log-normal distribution. This structure provides the foundation for modelling columns of ME tape. Initially an isolated column of ME tape was investigated. Grains were considered to be single domain and the dynamic process of the magnetic moments was explored by the Landau-Lifschitz equation. The model demonstrated that as the strength of the exchange coupling parameter increased, then moments which were strongly coupled resisted large negative fields and square hysteresis loops with a high coercivity were produced. Reversal of the moments was observed to be initiated at the ends of a column and then propagated throughout the column. This was attributed to large demagnetising fields and was particularly evident in the model with aligned easy axes. If the easy axes were randomly orientated then more disorder was present in the model and moments rotated incoherently. This produced hysteresis loops that were less square than those of the aligned model. The results also showed how the microstructure influenced the reversal processes

  9. Dynamic response of HTS composite tapes to pulsed currents

    International Nuclear Information System (INIS)

    Meerovich, V; Sokolovsky, V; Prigozhin, L; Rozman, D

    2006-01-01

    Dynamic voltage-current characteristics of an HTS Ag/BiSCCO composite tape are studied both experimentally and theoretically. The tape is subjected to pulsed currents with different shapes and magnitudes and voltage traces are measured using the four-point method with different locations of potential taps on the sample surface. Clockwise and anticlockwise hysteresis loops are obtained for the same sample depending on the location of the potential taps. The dynamic characteristics deviate substantially from the DC characteristic, especially in the range of low voltages where a criterion for the critical current value is usually chosen (1-10 μV cm -1 ). The critical current determined from dynamic characteristics and its change with the pulse magnitude depend on the location of the potential taps and on the curve branch chosen for the critical current determination (ascending or descending). The theoretical analysis is based on a model of the magnetic flux diffusion into a composite tape for a superconductor described by the flux creep characteristic. Numerical simulation based on this model gives results in good agreement with the experimental ones and explains the observed peculiarities of the dynamic characteristics of HTS composite tapes. The difference between the magnetic diffusion into a tape and a slab is discussed

  10. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, K. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)], E-mail: Kazunari.Motohashi@jp.sony.com; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)

    2008-11-15

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M{sub r}t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape.

  11. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    International Nuclear Information System (INIS)

    Motohashi, K.; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S.

    2008-01-01

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M r t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape

  12. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  13. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  14. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T; Nguyen, H. D.; Takehara, K.; Etoh, T. G.

    2010-01-01

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  15. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    Science.gov (United States)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  16. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  17. Percolation modelling for highly aligned polycrystalline superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, N A; Glowacki, B A; Evetts, J E [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); IRC in Superconductivity, Madingley Road, Cambridge CB3 0HE (United Kingdom)

    2000-11-01

    Surface and bulk texture measurements have been carried out on highly aligned NiFe tapes, suitable for use as coated conductor substrates. Data from small-area electron backscatter diffraction measurements are compared with those from bulk x-ray analysis in the development of a two-dimensional percolation model, and the two are shown to give very similar results. No evidence of grain-to-grain correlation is found. The model is then developed to assess how the properties of a superconducting layer grown epitaxially on buffered tapes will depend on parameters such as sample size, grain size and the extent of grain alignment. (author)

  18. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology and Obstetr......INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...

  19. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  20. Properties of hot pressed MgB2/Ti tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Melisek, T.; Fedor, J.; Cambel, V.; Morawski, A.; Kario, A.

    2009-01-01

    Hot axial and hot isostatic pressing was applied for single-core MgB 2 /Ti tapes. Differences in transport current density, n-exponents and critical current anisotropy are discussed and related to the grain connectivity influenced by pressing. The magnetic Hall probe scanning measurements allowed observing the isolated regions for axially hot pressed sample attributed to the longitudinally oriented cracks introduced by pressing. The highest current densities were measured for the tape subjected to hot isostatic pressing due to improved connectivity.

  1. New concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1980-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 millimeter wide recording tape 116 meters long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation

  2. A new concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1981-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 mm wide recording tape 116 m long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation. (orig.)

  3. Comparison of post-obturation pain experience following one-visit and two-visit root canal treatment on teeth with vital pulps: a randomized controlled trial.

    Science.gov (United States)

    Wang, C; Xu, P; Ren, L; Dong, G; Ye, L

    2010-08-01

    To compare the incidence and intensity of post-obturation pain after one- or two-visit root canal treatment (RCT) on anterior teeth with vital pulps and a single root and canal in a randomized controlled trial. One hundred patients requiring RCT on permanent anterior teeth with vital pulps preoperatively were included. The patients were assigned randomly into two groups of 50 patients each. After local anaesthesia, isolation, access and pulp extirpation, the canals of all teeth were prepared using engine-driven rotary ProTaper nickel-titanium instruments in a crown-down technique and irrigated with 2.5% NaOCl. The teeth in group 1 (n = 50) were filled with AH Plus sealer and gutta-percha using a lateral compaction technique at the first visit, whilst those in group 2 (n = 50) were medicated with a calcium hydroxide paste, a sterile dry cotton pellet and Caviton and scheduled for a second visit 7 days later. A modified verbal descriptor scale was used to measure preoperative pain and post-obturation pain at 6, 24, 48 h and 1 week after operation. Chi-square tests and independent-sample T-tests were used to compare the incidence and intensity of post-obturation pain of two groups at each interval. Eleven patients were excluded from the study as they failed to follow the scheduled revisit or their selected teeth had more than one root canal. Data were obtained from the remaining 89 patients. Forty-three patients were undergoing one-visit treatment (group 1) and 46 undergoing two-visit treatment (group 2). Most patients in both groups reported no pain or only slight pain within each post-obturation interval, only one in group 1 and one in group 2 had flare-ups and slight swelling. There was no statistically significant difference in the incidence and intensity of post-obturation pain experienced by two groups. The incidence and intensity of post-obturation pain experience following one- or two-visit RCT on teeth with vital pulps and a single canal were not

  4. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  5. Kinesthetic taping improves walking function in patients with stroke

    DEFF Research Database (Denmark)

    Boeskov, Birgitte; Carver, Line Tornehøj; von Essen-Leise, Anders

    2014-01-01

    BACKGROUND: Stroke is an important cause of severe disability and impaired motor function. Treatment modalities that improve motor function in patients with stroke are needed. The objective of this study was to investigate the effect of kinesthetic taping of the anterior thigh and knee on maximal...... be a valuable adjunct in physical therapy and rehabilitation of patients with stroke....

  6. Cutting red tape: national strategies for administrative simplification

    National Research Council Canada - National Science Library

    Cerri, Fabienne; Hepburn, Glen; Barazzoni, Fiorenza

    2006-01-01

    ... when the topic was new, and had a strong focus on the tools used to simplify administrative regulations. Expectations are greater today, and ad hoc simplification initiatives have in many cases been replaced by comprehensive government programmes to reduce red tape. Some instruments, such as one-stop shops, which were new then, have become widely adop...

  7. Researchers wrangle petabytes of data storage with NAS, tape

    CERN Multimedia

    Pariseau, Beth

    2007-01-01

    "Much is made in the enterprise data storage industry about the performance of disk systems over tape drives, but the managers of one data center that has eached the far limits of capacity say otherwise. Budget and performance demands forced them to build access protocols and data management tools for disk systems from scratch."

  8. Kodak phase-change media for optical tape applications

    Science.gov (United States)

    Tyan, Yuan-Sheng; Preuss, Donald R.; Olin, George R.; Vazan, Fridrich; Pan, Kee-Chuan; Raychaudhuri, Pranab. K.

    1993-01-01

    The SbInSn phase-change write-once optical medium developed by Eastman Kodak Company is particularly suitable for development into the next generation optical tape media. Its performance for optical recording has already been demonstrated in some of the highest performance optical disk systems. Some of the key performance features are presented.

  9. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  10. Tape casting and partial melting of Bi-2212 thick films

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, D.; Lang, T.; Heeb, B. [Nichtmetallische Werkstoffe, Zuerich (Switzerland)] [and others

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  11. Modeling and Velocity Tracking Control for Tape Drive System ...

    African Journals Online (AJOL)

    Modeling and Velocity Tracking Control for Tape Drive System. ... Journal of Applied Sciences and Environmental Management ... The result of the study revealed that 7.07, 8 and 10 of koln values met the design goal and also resulted in optimal control performance with the following characteristics 7.31%,7.71% , 9.41% ...

  12. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.

  13. The Catalog: A Flexible Data Structure for Magnetic Tape.

    Science.gov (United States)

    Kay, Martin; Ziehe, Theodore

    This report outlines a generalized storage scheme for large files of highly structured data, or catalogs, and describes their realization on magnetic tape. Each datum, large or small, is assigned to one of a number of data classes of which a user may define any number. The over-all organization of a catalog is given by a map that imposes a tree…

  14. Cervical ectopic pregnancy: Mersilene tape in surgical management

    African Journals Online (AJOL)

    2 Division of Obstetrics and Gynaecology, Mediclinic Hospital, Nelspruit, Mpumalanga, South Africa. Corresponding author: A A ... case of cerv ical ectopic pregnancy that was managed using cervical cerclage with Mersilene tape as an interven tion to reduce intraoperative haemorrhage during evacuation. Case report.

  15. Numerical Modeling of Fluid Flow in the Tape Casting Process

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2011-01-01

    The flow behavior of the fluid in the tape casting process is analyzed. A simple geometry is assumed for running the numerical calculations in ANSYS Fluent and the main parameters are expressed in non-dimensional form. The effect of different values for substrate velocity and pressure force...

  16. Oblique sputtered and evaporated magnetic thin films for tape recording

    NARCIS (Netherlands)

    Bijker, M.D.

    1998-01-01

    After having introduced some aspects of tape recording in chapter one, chapter two deals with the magnetron sputtering process itself. The kinetic energy of the electrons which are bound to the groove region by the combined action of the B and E field, was calculated. It was found that for a

  17. Critical current of high Tc superconducting Bi223/Ag tapes

    NARCIS (Netherlands)

    Huang, Y.; ten Haken, Bernard; ten Kate, Herman H.J.

    1998-01-01

    The magnetic field dependence of the critical current of various high Tc superconducting Bi2223/Ag tapes indicates that the transport current is carried through two paths: one is through weakly-linked grain boundaries (Josephson junctions); another is through well-connected grains. The critical

  18. Carbon tape microsampling for non-destructive analyses of artefacts

    Czech Academy of Sciences Publication Activity Database

    Bartůněk, V.; Varadzin, Ladislav; Zavřel, Jan

    -, - (2017) ISSN 1866-9557 R&D Projects: GA ČR(CZ) GAP405/10/2334 Institutional support: RVO:67985912 Keywords : microsampling * SEM-EDS * conducting SEM carbon tape * non-ferrous metallurgy * moulds * Early Middle Ages Subject RIV: AC - Archeology, Anthropology, Ethnology OBOR OECD: Archaeology Impact factor: 1.844, year: 2016

  19. Strategic flat rolling of Ag/BSCCO-2223 tapes

    DEFF Research Database (Denmark)

    Nielsen, Morten Storgård; Bech, Jakob Ilsted; Eriksen, Morten

    2002-01-01

    In the process of single-step flat rolling of multifilament Ag/BSCCO-2223 wire to tape previous work has shown the optimum strategy giving maximum critical current density to be it balance between the length and width strain, so they are of equal size i.e. so, that the logarithmic strain ratio, L...

  20. Study on influence of irradiation vulcanization to silicon rubber autohesive tape's properties

    International Nuclear Information System (INIS)

    Chen Chun; Tang Jian; Wu Ling; Han Yingchun; Zhou Hong; Mo Yan; Fu Haijun

    2006-01-01

    After using 60 Co γ-ray to irradiate vulcanization silicon rubber autohesive tape, the effect of absorbed dose to the autohesive tape's tensile strength, elongation at break, autohesion and breakdown voltage strength and dose rate's effect to the autohesive tape's properties were studied. The results indicate that autohesive tape's tensile strength increases and the elongation at break decreases with the increasing dose. Under the dose of 25 kGy, the tape's autohesion increases with the increasing dose. When the dose is up to 25 kGy, the tape's autohesion achieves to the maximum, and then decreases with the increasing dose. Absorbed dose has no effect to the tape's breakdown voltage strength, and the dose rate has no effect to the autohesive tape's properties. (authors)

  1. Optimization of the tape placement process parameters for carbon–PPS composites

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, B.; Visser, Roy; Akkerman, Remko

    2013-01-01

    The interrelation between process parameters, material properties and interlaminar bond strength is investigated for the laser assisted tape placement process. Unidirectionally carbon reinforced poly(phenylene sulfide) (PPS) tapes were welded onto carbon woven fabric reinforced PPS laminates. The

  2. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  3. Ultrasound assessment of tension-free vaginal tape (TVT).

    Science.gov (United States)

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    OpenAIRE

    Brendon A. Parsons; Olivia Lin Smith; Myeong Chae; Veljko Dragojlovic

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better...

  5. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (pProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary

  6. Evaluation of microleakage in single-rooted teeth obturated with thermoplasticized gutta-percha using various endodontic sealers: an in-vitrostudy

    International Nuclear Information System (INIS)

    Lone, M.M.; Khan, F.; Lone, M.A.

    2018-01-01

    Objective:To compare apical microleakage of extracted, single-rooted teeth obturated with thermoplasticized injectable gutta-percha using two different endodontic sealers (calcium-hydroxide and resin based). Study Design:An experimental study. Place and Duration of Study:The Aga Khan University Hospital (AKUH), Dental Clinics and Laboratory from June to September 2015. Methodology:The study was conducted using extracted teeth. After access cavities were made, cleaning and shaping of root canals was done in 70 teeth. Teeth were randomly allocated into two groups and obturated with thermoplasticized injectable gutta-percha (Obtura II) using two sealers (Sealapex vs.AH plus). After immersing the teeth in 2.0% methylene blue, they were split longitudinally, viewed under light microscope (magnification X4) and images were taken by a camera connected to microscope. The extent of dye penetration was assessed from apex to its coronal part and recorded in millimeters. Independent sample t-test was used to compare microleakage in the two groups. Pearson correlation coefficient was used for inter-examiner reliability of dye penetration measurements. A p-value of <0.05 was taken as statistically significant. Results:Teeth obturated with Obtura II gutta-percha with AH plus sealer had a mean dye penetration of 1.20 +- 0.79 mm. This was significantly better than Obtura II with Sealapex sealer (p=0.003). Conclusion:Obtura II-AH plus sealer was a better combination for obturation as it showed a lesser degree of microleakage. Obtura II with Sealapex group showed higher microleakage, so this combination should be avoided in single-rooted teeth. (author)

  7. Enhancement of turbulent flow heat transfer in a tube with modified twisted tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Y.G.; Zhao, C.H.; Song, C.F. [College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan (China)

    2012-12-15

    Numerical simulations were performed to study the fluid flow and heat transfer in a tube with staggered twisted tapes with central holes. In the range of Reynolds numbers between 6000 and 28 000, the modified twisted tapes increased the Nusselt number by 76.2 {proportional_to} 149.7 % and the friction factor by 380.2 {proportional_to} 443.8 % compared to the smooth tube. Compared to the typical twisted tapes, the modified twisted tapes produced an acceleration flow through the triangle regions leading to the enhancement of heat transfer, and the holes in the modified tapes reduced the severe pressure loss. It was found that the modified twisted tapes decreased the friction factor by 8.0 {proportional_to} 16.1 % and enhanced the heat transfer by 34.1 {proportional_to} 46.8 % in comparison with the typical tapes. These results indicated that the performance ratio values of the tube with modified twisted tapes were higher than 1.0 in the range of Reynolds numbers studied. The computed performance ratios of the tube with modified twisted tapes were much higher than those of the tube with typical twisted tapes. This means that the integrated performance of the tube with staggered twisted tapes with central holes is superior to that of the tube with typical twisted tapes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  9. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator.

    Science.gov (United States)

    Michelinakis, George

    2017-01-01

    This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  10. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator

    Directory of Open Access Journals (Sweden)

    George Michelinakis

    2017-01-01

    Full Text Available This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  11. Comparison of quality of obturation and instrumentation time using hand files and two rotary file systems in primary molars: A single-blinded randomized controlled trial.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G

    2017-01-01

    In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.

  12. Structural properties of superconducting Bi-2223/Ag tapes

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalck Andersen, L.

    2001-05-01

    The structural properties of silver clad high-T{sub c} superconducting ceramic tapes of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) have been investigated by means of synchrotron X-ray diffraction (including the 3DXRD microscope setup), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDS). By synchrotron X-ray diffraction in situ studies of the phase development during the transformation of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 1}Cu{sub 2}O{sub x} (Bi-2212) into Bi-2223, the stoichiometry changes and the texture have been performed during annealing in 8% O{sub 2} and in air. Furthermore, an annealing with two high temperature cycles has been performed to study the equilibrium phenomena. During heating (Ca,Sr){sub 2}PbO{sub 4} decomposes at temperatures between 700 deg. C and 840 deg.C. Simultaneously, the Bi-2212 lattice contracts, indicating an incorporation of Pb. Moreover, the grain mis-alignment decreases significantly. In air we have observed that Bi-2212 partly dissociates into (Ca,Sr){sub 2}CuO{sub 3} and a liquid at temperatures above 812 deg. C. At the annealing temperature Bi-2212 and (Ca,Sr){sub 2}CuO{sub 3} react with the liquid to form Bi-2223. The transformation mechanism is discussed. During cooling below {approx}750 deg.C (Ca,Sr){sub 2}CuO{sub 3} and the liquid mainly transform into Bi-2201. Below {approx}780 deg. C Bi-2223 decomposes to 3221. In addition, a two-step cooling experiment and a decomposition study have been performed in 8% O{sub 2}. By TEM the grain and colony size in the c-axis direction, the angles of c-axis tilt grain boundaries and the intergrowth content are investigated. A fully processed tape has on average 50% thicker grains than a tape after the 1st annealing. The angles of c-axis tilt grain boundaries are on average 14 deg. and 26 deg. for the fully processed tape and the tape after the 1st annealing, respectively. The intergrowth content (15%) and

  13. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    Directory of Open Access Journals (Sweden)

    Lu Szu-Ching

    2011-08-01

    Full Text Available Abstract Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively were recruited. All participants performed vertical jump tests prior to (without taping and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  14. The Efficacy of the WaveOne Reciprocating File System versus the ProTaper Retreatment System in Endodontic Retreatment of Two Different Obturating Techniques.

    Science.gov (United States)

    Jorgensen, Ben; Williamson, Anne; Chu, Rene; Qian, Fang

    2017-06-01

    This ex vivo study aimed to evaluate the efficacy of retreating GuttaCore (Dentsply Tulsa Dental Specialties, Tulsa, OK) and warm vertically condensed gutta-percha in moderately curved canals with 2 different systems: ProTaper Universal Retreatment (Dentsply Tulsa Dental) and WaveOne (Dentsply Tulsa Dental). Eighty mesial roots of mandibular molars were used in this study. The mesiobuccal canals in each sample were prepared to length with the WaveOne Primary file (Dentsply Tulsa Dental). The canals were obturated with either a warm vertical approach or with GuttaCore and divided into 4 retreatment groups with the same mean root curvature: warm vertical retreated with ProTaper, warm vertical retreated with WaveOne, GuttaCore retreated with ProTaper, and GuttaCore retreated with WaveOne. The warm vertical groups were obturated using a continuous-wave technique of gutta-percha compaction, and the GuttaCore groups were obturated according to the manufacturer's instructions. After allowing sealer to set, each specimen was retreated with either the ProTaper Universal Retreatment files D1, D2, or D3 or with the WaveOne Primary file to the predetermined working length. The time taken to reach the working length was recorded. Instrument fatigue and failure were also evaluated. The post hoc 2-sample t tests showed that the overall mean total time taken to reach the working length for the warm vertical groups was significantly greater than that observed for the GuttaCore groups (mean = 87.11 vs 60.16 seconds, respectively), and the overall mean total time taken to reach the working length for WaveOne was significantly greater than that observed for ProTaper (99.09 vs 48.18 seconds, respectively). Two-way analysis of variance showed a significant main effect for both the type of experiment groups (F 1,76  = 15.32, P = .0002) and the type of retreatments (F 1,76  = 54.67, P file underwent more separations than the ProTaper files. The WaveOne Primary file underwent

  15. A software package to process an INIS magnetic tape on the VAX computer

    International Nuclear Information System (INIS)

    Omar, A.A.; Mohamed, F.A.

    1991-01-01

    This paper presents a software package whose function is to process the magnetic tapes distributed by the Atomic Energy Agency, on the VAX computers. These tapes contain abstracts of papers in the different branches of nuclear field and is supplied from the international Nuclear Information system (INIS). Two goals are aimed from this paper. First it gives a procedure to process any foreign magnetic tape on the VAX computers. Second, it solves the problem of reading the INIS tapes on a non IBM computer and thus allowing the specialists to gain from the large amount of information contained in these tapes. 11 fig

  16. Kinesiology taping as an adjunct for pain management in cancer?

    Science.gov (United States)

    Banerjee, Gourav; Rebanks, Jonathan; Briggs, Michelle; Johnson, Mark I

    2016-07-14

    We present the case of a 46-year-old woman who developed severe pain described as 'tearing' and 'searing' in the left side of the mid-trapezius region near the thoracic 8 vertebra (T8). The patient had undergone surgery for T8 fracture which had resulted from metastasis (secondary breast cancer). A community nurse referred the patient for physiotherapy assessment and treatment for her musculoskeletal pain and related symptoms that had affected her mobility and functional activities. The patient was treated with soft tissue therapy with the addition of kinesiology taping on follow-up visits. Kinesiology tape was applied over her left side trapezius region and left shoulder. The patient reported significant reductions in pain severity and felt greater control and stability over her left shoulder region, which resulted in better function and overall quality of life measures. She did not report any adverse effects. 2016 BMJ Publishing Group Ltd.

  17. An Improvement in Thermal Modelling of Automated Tape Placement Process

    International Nuclear Information System (INIS)

    Barasinski, Anaies; Leygue, Adrien; Poitou, Arnaud; Soccard, Eric

    2011-01-01

    The thermoplastic tape placement process offers the possibility of manufacturing large laminated composite parts with all kinds of geometries (double curved i.e.). This process is based on the fusion bonding of a thermoplastic tape on a substrate. It has received a growing interest during last years because of its non autoclave abilities.In order to control and optimize the quality of the manufactured part, we need to predict the temperature field throughout the processing of the laminate. In this work, we focus on a thermal modeling of this process which takes in account the imperfect bonding existing between the different layers of the substrate by introducing thermal contact resistance in the model. This study is leaning on experimental results which inform us that the value of the thermal resistance evolves with temperature and pressure applied on the material.

  18. Conventional Tape versus Kinesiotape for Hallux Valgus Correction

    Directory of Open Access Journals (Sweden)

    Nadia Lotfy Radwan

    2017-01-01

    Full Text Available This study was commenced to compare the effect of Kinesiotape (KT versus conventional tape (CT on HVA and IMA as well as the intensity of pain from HV deformity. Methodology: Female patients with age 45 to 60 years and diagnosed with mild to moderate HV were included in the study. The foot pain intensity was assessed by visual analogue scale (VAS before applying tape and after completion of the study. Results: The outcome measures of pain intensity showed a non-significant difference between both groups before intervention (p>0.05. Within both KT and CT groups, the pre-and post-treatment scores were significantly different (p˂0.05. In the comparison of the post treatment scores, there was a significant difference (p˂0.05 between both groups favouring the KT group..

  19. Simulation of magnetization and levitation characteristics of HTS tape stacks

    Science.gov (United States)

    Anischenko, I. V.; Pokrovskii, S. V.; Mineev, N. A.

    2017-12-01

    In this work it is presented a computational model of a magnetic levitation system based on stacks of high-temperature second generation superconducting tapes (HTS) GdBa2Cu3O7-x. Calculated magnetic field and the current distributions in the system for different stacks geometries in the zero-field cooling mode are also presented. The magnetization curves of the stacks in the external field of a permanent NdFeB magnet and the levitation force dependence on the gap between the magnet and the HTS tapes stack were obtained. A model of the magnetic system, oriented to levitation application, is given. Results of modeling were compared with the experimental data.

  20. Low-Energy Traumatic Obturator Hip Dislocation with Ipsilateral Femoral Shaft Fracture in a Patient with Omolateral Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    G. Gazzotti

    2016-01-01

    Full Text Available Ipsilateral obturator hip dislocation and femoral shaft fracture are rare. We report such a case in an older woman after a low-energy injury. She had a knee prostheses in the same limb. The patient was treated by open manipulative reduction of the luxation without opening joint and open reduction and internal fixation of the femur with angular stability plate and screws. We could not find a similar case in the literature. An early diagnosis of the dislocation is crucial in order to obtain good results. Great awareness and radiologic examination are fundamental to achieve precocious diagnosis of both these rare combined injuries, as treatment in these cases is considered an emergency. The first step was an attempt to reduce the dislocation by closed means but it failed. Then we performed a short approach at the trochanteric region and used Lambotte forceps to manoeuvre the proximal femur without opening the joint achieving reduction. Thereafter the femoral shaft fracture underwent open reduction and internal fixation with an angular stable plate. After a 2-year follow-up the outcome was very good.

  1. Postoperative groin pain and success rates following transobturator midurethral sling placement: TVT ABBREVO® system versus TVT™ obturator system.

    Science.gov (United States)

    Canel, Virginie; Thubert, Thibault; Wigniolle, Ingrid; Fernandez, Hervé; Deffieux, Xavier

    2015-10-01

    Placement of a transobturator midurethral sling (MUS) is the standard surgical treatment for stress urinary incontinence. Most recent MUS procedures have been poorly evaluated. We compared the results using a "new" device expected to reduce postoperative pain, the TVT ABBREVO® system (TVT-Abb), with those using the TVT™ obturator system (TVT-O). This was a retrospective study comparing the use of the TVT-Abb (in 50 patients) and the TVT-O (in 50 patients). The main outcomes were the amount of postoperative pain, the success rate (no reported urinary leakage and negative cough test) with both MUS procedures, and the prevalence of complications. The mean follow-up time was 12 months. The preoperative characteristics of the two groups were comparable. There was less postoperative pain (VAS, 0 to 100) in the TVT-Abb group than in the TVT-O group (12.2 vs. 24.4, p TVT-Abb group and the TVT-O group (8 % vs. 12 %, p = 0.74). The prevalences of perioperative and postoperative complications (bladder/urethral injury, haemorrhage) in the two groups were equal. The success rates were similar at 12 months after surgery (88 % vs. 78 %, p = 0.29). The success rates with TVT-Abb and TVT-O were equal at 12 months after surgery, but there was less immediate postoperative pain with TVT-Abb.

  2. "The Political Business Cycle: New Evidence from the Nixon Tapes"

    OpenAIRE

    Burton A. Abrams; James L. Butkiewicz

    2011-01-01

    Drawing from the personal tape recordings made during the presidency of Richard Nixon, we uncover and report in this paper new evidence that Nixon manipulated Arthur Burns and the Federal Reserve Bank into creating a political business cycle that helped secure Nixon’s reelection victory in 1972. Nixon understood the risks that his desired monetary policy imposed, but chose to trade longer-term economic costs to the economy for his own short-term political benefit.

  3. El Digital Audio Tape Recorder. Contra autores y creadores

    Directory of Open Access Journals (Sweden)

    Jun Ono

    2015-01-01

    Full Text Available La llamada "DAT" (abreviatura por "digital audio tape recorder" / grabadora digital de audio ha recibido cobertura durante mucho tiempo en los medios masivos de Japón y otros países, como un producto acústico electrónico nuevo y controversial de la industria japonesa de artefactos electrónicos. ¿Qué ha pasado con el objeto de esta controversia?

  4. Modification of critical current in HTSC tape conductors by a ferromagnetic layer

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Seiler, E; Vojenciak, M; Granados, X

    2008-01-01

    In some applications of tape conductors from high temperature superconductors (HTSC) the magnetic field is created by the transported current itself. This is e.g. the case of power transmission cables or current leads. Quite complex distribution of local magnetic field determines then the ability of the superconducting element to carry electrical current. We have investigated how much the critical current of a tape conductor can be changed by putting a ferromagnetic layer in the vicinity of the HTSC material. Numerical procedure has been developed to resolve the current and field distribution in such superconductor-ferromagnet composite tape. Theoretical predictions have been confirmed by experiments on sample made from Bi-2223/Ag composite tape. The critical current of such tape can be improved by placing a soft ferromagnetic material at the tape's edges. On the other hand, the calculations show that the ferromagnetic substrate of YBCO coated tape reduces its self-field critical current

  5. Technical and economical evaluation of tape drip and drip line irrigation systems in a strawberry greenhouse

    Directory of Open Access Journals (Sweden)

    Soghra HOSSEINIAN

    2016-04-01

    Full Text Available This study was done in a strawberry greenhouse to examine the technical and the economical evaluation of two drip irrigation systems including the tape and the drip line in the northern part of Iran. The result showed that all of the technical indices with tape were higher than drip line, and due to statistical analysis reveal a significant difference (P < 0.05. Yield and water productivity (WP with tape were higher than drip line (P < 0.05. Benefit per drop (BPD and net benefit per drop (NBPD with tape were higher than drip line. Net present value, internal rate of capital return and benefit to cost ratio in drip line were higher than tape. In general, regarding technical evaluation tape was better than drip line, besides according to the economical evaluation the drip ­lines were better than tape.

  6. Simulation of YBCO Tape and Coils in HTS Maglev System

    Directory of Open Access Journals (Sweden)

    Song Mengxiao

    2017-01-01

    Full Text Available In the process of running high temperature superconducting maglev train, the AC(Alternating Current loss of superconducting coil is directly related to its safe operation and operating cost. In this paper, the simulation model was built based on the finite element software COMSOL Multiphysics, and mainly simulated and calculated the AC losses of YBCO(Yttrium Barium Copper Oxide tape and coils. In this model, as the solving object, the singular and infinite long YBCO tape and coils model was solved with H-formulation and the nonlinear characteristic (E-J constitutive law and anisotrophy (B-J characteristic were taken into consideration as the theoretical foundation. Then on the basis of the model under maglev suspension system, AC losses under different amplitude and frequence AC currents were calculated. The results shows that under different frequencies and dynamic components, the local maximum AC loss of YBCO tape and coils occurs when the steady-state DC(Direct Current current is 30A. Then comparing with old maglev suspension system, the new system can greatly reduce the energy consumption and the material cost.

  7. Low back pain during pregnancy and Kinesio tape application.

    Science.gov (United States)

    Reyhan, Aycan Çakmak; Dereli, Elif Elçin; Çolak, Tuğba Kuru

    2017-01-01

    Low back pain is a common problem during pregnancy. Although the pain usually occurs in the third trimester, it might be seen in the first trimester, too. There are various types of applications for the treatment of low back pain during pregnancy. However, there is a lack of evidence for the effectiveness of each method. If there is not an obvious deficit, bed rest, exercise, conventional physiotherapy, using protective principles for the lumbar area are recommended, since the main and the only complaint is low back pain. It is aimed in the current review to investigate the use of Kinesio tape in the low back pain seen during pregnancy and to review the literature related to this subject. There are only a few studies investigating the effect of Kinesio tape during pregnancy in the literature and they mostly did not aim to study the low back pain, further evidence and studies are needed to investigate the use of Kinesio tape for the low back pain seen during pregnancy as there is not evidence strong enough. Kinesiotape application aims to increase circulation and mobility, and regarding these gains decreased pain and increased performance are expected.

  8. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  9. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  10. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    International Nuclear Information System (INIS)

    Gopal, K.; Lim, Y.; Banerjee, B.

    2005-01-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus

  11. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    Science.gov (United States)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  12. Buffer layers grown by replicating the texture of an original template tape

    International Nuclear Information System (INIS)

    Lim, Sunme; Yoo, Jaeun; Park, Chan; Youm, Dojun

    2007-01-01

    We propose a fabrication method of the buffer layers, whose biaxial textures are replicated from an original template tape. The purpose of this method is economical texturing process for coated conductors. At first we prepared a biaxially textured metal tape (TM-tape). Then a sacrifice layer (SA), a buffer layer (BU) and a thick metallic layer (SM) were sequentially deposited on the TM-tape. SA-layer and BU-layer were deposited epitaxially to copy the texture of the TM-tape. SA-layer was dissoluble in water. SM-layer with the textured BU-layer was separated and could be used for a supporting tape for the further growth of a superconducting layer. In this way, it is possible to reuse the original textured TM-tape many times. In this paper, we report the results of our experiments, in which we used a biaxially Ni tape, BaO film, STO film, and a thick Ag film for TM-tape, SA-layer, BU-layer, and SM-layer, respectively. The Ag/STO layers were successfully separated form the Ni tape by dissolving the BaO layer in water. The texture quality of the STO layer was well secured after the separation

  13. Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Wang, Tao; Zhang, Yong

    2015-01-01

    Purpose: To assess the efficacy and safety of tension-free vaginal tape (TVT)-Secur for stress urinary incontinence (SUI). Methods: A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register. Results: Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O) and TVT. We found that TVT-Secur had significant reductions in operative time, visual analog score for pain, and postoperative complications compared with TVT-O. Even though TVT-Secur had a significantly lower subjective cure rate (PTVT-O at 1 to 3 years, there was no significant difference between TVT-Secur and TVT-O in the subjective cure rate (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.22–1.08; P=0.08), objective cure rate (OR, 0.49; 95% CI, 0.22–1.09; P=0.08), or complications at 3 to 5 years. Moreover, TVT-Secur had significantly lower subjective and objective cure rates compared with TVT. Conclusions: This meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur. PMID:26739179

  14. Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wei Huang

    2015-12-01

    Full Text Available Purpose: To assess the efficacy and safety of tension-free vaginal tape (TVT-Secur for stress urinary incontinence (SUI. Methods: A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register. Results: Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O and TVT. We found that TVT-Secur had significant reductions in operative time, visual analog score for pain, and postoperative complications compared with TVT-O. Even though TVT-Secur had a significantly lower subjective cure rate (P<0.00001, lower objective cure rate (P<0.00001, and higher intraoperative complication rate, compared with TVT-O at 1 to 3 years, there was no significant difference between TVT-Secur and TVT-O in the subjective cure rate (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.22–1.08; P=0.08, objective cure rate (OR, 0.49; 95% CI, 0.22–1.09; P=0.08, or complications at 3 to 5 years. Moreover, TVT-Secur had significantly lower subjective and objective cure rates compared with TVT. Conclusions: This meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur.

  15. Magnetization reversal in an obliquely oriented metal evaporated tape

    International Nuclear Information System (INIS)

    Srinath, S.; Vavassori, P.; Rekveldt, M.Th.; Cook, R.E.; Felcher, G.P.

    2004-01-01

    Magnetization reversal in obliquely oriented metal evaporated videotapes as a function of the tape depth was studied by vector magneto-optic Kerr effect and polarized neutron reflectivity. The magnetization vector was found to rotate coherently out-of-plane by an angle α during the magnetization reversal for a substantial part of the hysteresis cycle. However α differs between the surface-facing and the substrate-facing sides of the film, with the more oxidized surface layer following closely the applied field. Close to M∼0 the film breaks down magnetically into a collage of small domains, reflecting the crystalline microstructure of the material

  16. Electric currents in REBaCuO superconducting tapes

    Czech Academy of Sciences Publication Activity Database

    Jirsa, Miloš; Rameš, Michal; Ďuran, Ivan; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-01-01

    Roč. 30, č. 4 (2017), 1-8, č. článku 045010. ISSN 0953-2048 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:68378271 ; RVO:61389021 Keywords : superconducting tapes * REBaCuO * critical currents * induction and transport * pinning force density * magnetic relaxation * neutron irradiation Subject RIV: BM - Solid Matter Physics ; Magnetism; BL - Plasma and Gas Discharge Physics (UFP-V) OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.); Fluids and plasma physics (including surface physics) (UFP-V) Impact factor: 2.878, year: 2016

  17. Cache management of tape files in mass storage system

    International Nuclear Information System (INIS)

    Cheng Yaodong; Ma Nan; Yu Chuansong; Chen Gang

    2006-01-01

    This paper proposes the group-cooperative caching policy according to the characteristics of tapes and requirements of high energy physics domain. This policy integrates the advantages of traditional local caching and cooperative caching on basis of cache model. It divides cache into independent groups; the same group of cache is made of cooperating disks on network. This paper also analyzes the directory management, update algorithm and cache consistency of the policy. The experiment shows the policy can meet the requirements of data processing and mass storage in high energy physics domain very well. (authors)

  18. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample

  19. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)]. E-mail: alam643@yahoo.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)

    2005-08-15

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample.

  20. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  1. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    International Nuclear Information System (INIS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-01-01

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  2. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  3. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  4. Numerical Modeling of the Side Flow in Tape Casting of a Non-Newtonian Fluid

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2013-01-01

    in the tape casting process is modeled numerically with ANSYS FLUENT in combination with an Ostwald-de Waele power law constitutive equation. Based on rheometer experiments, the constants in the Ostwald-de Waele power law are identified for the considered LSM material and applied in the numerical modeling......One of the most common ways used to produce multilayer ceramics (MLC) is tape casting. In this process, the dried tape thickness is of great interest to control the desired products and applications. One of the parameters that influences the final tape thickness is the side flow factor (a) which...... is mostly measured at the end of the process by a volumetric comparison of the tape which flowed outside the casting width to the tape within the casting width. This phenomenon has not been predicted theoretically yet in the literature. In this study, the flow of (La0.85Sr0.15)0.9MnO3 (LSM) slurry...

  5. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  6. Study of the inhomogeneity of critical current under in-situ tensile stress for YBCO tape

    Science.gov (United States)

    Zhu, Y. P.; Chen, W.; Zhang, H. Y.; Liu, L. Y.; Pan, X. F.; Yang, X. S.; Zhao, Y.

    2018-07-01

    A Hall sensor system was used to measure the local critical current of YBCO tape with high spatial resolution under in-situ tensile stress. The hot spot generation and minimum quench energy of YBCO tape, which depended on the local critical current, was calculated through the thermoelectric coupling model. With the increase in tensile stress, the cracks which have different dimensions and critical current degradation arose more frequently and lowered the thermal stability of the YBCO tape.

  7. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    OpenAIRE

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests a...

  8. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    OpenAIRE

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin ...

  9. Control program for punched paper tape for the PDP-8/1 computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    A program was developed for the PDP-8/1 computer to control the punched paper tape supplied by the measuring instruments. Any departure from the program is detected by an optical reader which stops the tape and displays the error on an accumulator. This program which is suitable for large amounts of data punched on paper tape has been in use at the Beer-Sheva laboratories for detecting errors in the sample changing operation. (B.G.)

  10. Bending strain study of Bi-2223/Ag tapes using Hall sensor magnetometry

    International Nuclear Information System (INIS)

    Lahtinen, M.; Paasi, J.; Sarkaniemi, J.; Han, Z.; Freltoft, T.

    1996-01-01

    The influence of room temperature bending on critical current (I c ) of Bi-2223/Ag tapes is studied by Hall sensor magnetometry, four-point method and scanning electron microscopy. Hall sensor magnetometry allows one to assess tape homogeneity and the amount of mechanical damage caused by bending. The microstructure of the Bi-2223 ceramic is found to strongly affect the tape behavior under bending strain. In a tape with moderate I c = 6.1 A at 77 K and a porous ceramic core, crack propagation took place normal to the Ag-ceramic interface, whereas in tapes with dense core, I c above 10 A at 77 K, cracks propagated in the tape plane. In monofilamentary tapes core homogeneity correlated with good bending strain performance. In multifilamentary tapes crack propagation between filaments was prohibited by the Ag matrix, thus leading to enhanced strain tolerance. In the high I c tapes studied, bending to 25 mm radius resulted in 1%--2% I c degradation

  11. Current distribution and enhancement of the engineering critical current density in multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Jensen, M.B.; Kindl, B.

    2000-01-01

    The spatial distribution of the critical current density (Jc) and engineering critical current density (Je) along the tape width direction was studied by a cutting technique on Bi-2223 multifilamentary tapes. In general, an increase of Jc towards the centre of the tape was measured. We attribute...... microstructure with a great amount of secondary phases. Local variation of Jc was measured within the centre segment of the tape. This indicates the influence of other factors on Jc, such as filament shape, connectivity of the filaments, and sausaging. Enhancement of Je has been pursued in which average Je of 12...

  12. The Variation of Interface Formation with Slurry Viscosity Change in Side-By-Side Tape Casting

    DEFF Research Database (Denmark)

    Bulatova, Regina; Jabbari, Masoud; Andersen, Kjeld Bøhm

    Homogenous and flexible adjacently graded tapes were produced by casting the organic-based slurries simultaneously. To develop side-by-side tape casing (SBSTC), the material optimization, modernization of the doctor blade design, and parameters control of such processes as casting, drying, de......-bindering and sintering were studied. Solvent and binder concentrations were varied in order to optimize co-casting flow, as well as the drying and sintering shrinkage. Tapes were evaluated in terms of rheological behavior of the slurries, the green and sintered tape microstructure, the quality of the interface area...

  13. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  14. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  15. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    Science.gov (United States)

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  16. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  17. Magnetic field profiles of NbTi tapes

    International Nuclear Information System (INIS)

    Migliori, A.; Taylor, R.D.; Bartlett, R.D.

    1976-01-01

    Magnetic field profile measurements were performed on stabilized NbTi tapes in zero applied field carrying large transport current densities. Field profile data were taken on large diameter superconducting sample loops at temperatures between 2 0 K and T/sub c/ (about 9.2 0 K) and several persistent currents up to I/sub c/(T), the maximum. The field profiles scaled with current, independent of temperature, at temperatures below 8.5 0 K and were well described by an elliptical shell approximation which left a current-free, field-free central region. Critical state models applied to this self-field situation proved inadequate. Complex profiles produced by trapped flux in the tape loop were described quantitatively by assuming concentric elliptical shells each with a different current density. The maximum current which could be persisted in the loop at each temperature was linear from 4 to 8.5 K. The effective resistance of the superconducting loop including its joint was less than 10 -13 ohms

  18. Eccentric Exercise, Kinesiology Tape, and Balance in Healthy Men.

    Science.gov (United States)

    Hosp, Simona; Folie, Ramona; Csapo, Robert; Hasler, Michael; Nachbauer, Werner

    2017-07-01

      Deficits in balance have been identified as a possible risk factor for knee injuries in athletes. Despite a lack of evidence for its effectiveness, kinesiology tape (KT) is widely used to prevent knee injuries.   To investigate the influence of KT at the knee joint on balance ability in healthy men after eccentric exercise.   Crossover study.   University laboratory.   Twelve young men with no history of lower limb injury volunteered for the study (age = 23.3 ± 2.6 years). All participants were students enrolled in a sports science program.   Participants performed the balance test with and without KT at the knee joint on 2 separate days.   The ability to maintain balance was assessed during a single-legged-stance test using a computerized balance-stability test system. The test was performed before and after 30 minutes of downhill walking on a treadmill.   Eccentric exercise resulted in a deterioration of balance ability, which was attenuated by the use of KT. Further analyses revealed that the effectiveness of KT depended on the participant's balance status, with the preventive effect being greater in participants presenting with poorer baseline balance ability.   Applied to the knee joint, KT counteracted the exercise-related deterioration of balance ability observed when no tape was used. Participants presenting with below-average balance ability received more benefit from KT. By preventing exercise-related impairment of balance ability, KT might help to reduce the risk of sport-associated knee injuries.

  19. Self-field AC losses in Bi-2223 superconducting tapes

    International Nuclear Information System (INIS)

    Mueller, K. H.; Leslie, K.E.

    1996-01-01

    Full text: The self-field AC loss in Bi-2223 silver sheathed tapes for AC currents of up to 100 A was measured at 77 K and frequencies of 60 Hz and 600 Hz using a lock-in amplifier. The frequency dependence indicated a purely hysteretic loss which can be well described in terms of the critical state model for a flat superconducting strip. The only parameter needed to predict the self-field AC loss is the critical current of the critical state. Because the loss voltage is extremely small compared with the inductive voltage, a very high accuracy of the lock-in amplifier phase setting is required. Unlike in loss measurements on cylindrical superconducting samples, in the case of the tape the measuring circuit leads have to be brought out from the surface forming a loop where the changing magnetic field induces an additional voltage. Only if the loop formed by the leads at the voltage tabs is large enough will the apparent power dissipation approach the real AC loss associated with the length of the sample probed

  20. Numerical modeling of laser assisted tape winding process

    Science.gov (United States)

    Zaami, Amin; Baran, Ismet; Akkerman, Remko

    2017-10-01

    Laser assisted tape winding (LATW) has become more and more popular way of producing new thermoplastic products such as ultra-deep sea water riser, gas tanks, structural parts for aerospace applications. Predicting the temperature in LATW has been a source of great interest since the temperature at nip-point plays a key role for mechanical interface performance. Modeling the LATW process includes several challenges such as the interaction of optics and heat transfer. In the current study, numerical modeling of the optical behavior of laser radiation on circular surfaces is investigated based on a ray tracing and non-specular reflection model. The non-specular reflection is implemented considering the anisotropic reflective behavior of the fiber-reinforced thermoplastic tape using a bidirectional reflectance distribution function (BRDF). The proposed model in the present paper includes a three-dimensional circular geometry, in which the effects of reflection from different ranges of the circular surface as well as effect of process parameters on temperature distribution are studied. The heat transfer model is constructed using a fully implicit method. The effect of process parameters on the nip-point temperature is examined. Furthermore, several laser distributions including Gaussian and linear are examined which has not been considered in literature up to now.

  1. Superior perioperative analgesia with combined femoral-obturator-sciatic nerve block in comparison with posterior lumbar plexus and sciatic nerve block for ACL reconstructive surgery.

    Science.gov (United States)

    Bareka, Metaxia; Hantes, Michael; Arnaoutoglou, Eleni; Vretzakis, George

    2018-02-01

    The purpose of this randomized controlled study is to compare and evaluate the intraoperative and post-operative outcome of PLPS nerve block and that of femoral, obturator and sciatic (FOS) nerve block as a method of anaesthesia, in performing ACL reconstruction. Patients referred for elective arthroscopic ACL reconstruction using hamstring autograft were divided in two groups. The first group received combined femoral-obturator-sciatic nerve block (FOS Group) under dual guidance, whereas the second group received posterior lumbar plexus block under neurostimulation and sciatic nerve block (PLPS Group) under dual guidance. The two groups were comparable in terms of age, sex, BMI and athletic activity. The time needed to perform the nerve blocks was significantly shorter for the FOS group (p block under dual guidance for arthroscopic ACL reconstructive surgery is a safe and tempting anaesthetic choice. The success rate of this technique is higher in comparison with PLPS and results in less peri- and post-operative pain with less opioid consumption. This study provides support for the use of peripheral nerve blocks as an exclusive method for ACL reconstructive surgery in an ambulatory setting with almost no complications. I.

  2. Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-03-01

    Full Text Available Questions: Is Kinesio Taping more effective than a sham taping/placebo, no treatment or other interventions in people with musculoskeletal conditions? Is the addition of Kinesio Taping to other interventions more effective than other interventions alone in people with musculoskeletal conditions? Design: Systematic review of randomised trials. Participants: People with musculoskeletal conditions. Intervention: Kinesio Taping was compared with sham taping/placebo, no treatment, exercises, manual therapy and conventional physiotherapy. Outcome measures: Pain intensity, disability, quality of life, return to work, and global impression of recovery. Results: Twelve randomised trials involving 495 participants were included in the review. The effectiveness of the Kinesio Taping was tested in participants with: shoulder pain in two trials; knee pain in three trials; chronic low back pain in two trials; neck pain in three trials; plantar fasciitis in one trial; and multiple musculoskeletal conditions in one trial. The methodological quality of eligible trials was moderate, with a mean of 6.1 points on the 10-point PEDro Scale score. Overall, Kinesio Taping was no better than sham taping/placebo and active comparison groups. In all comparisons where Kinesio Taping was better than an active or a sham control group, the effect sizes were small and probably not clinically significant or the trials were of low quality. Conclusion: This review provides the most updated evidence on the effectiveness of the Kinesio Taping for musculoskeletal conditions. The current evidence does not support the use of this intervention in these clinical populations. PROSPERO registration: CRD42012003436. [Parreira PdCS, Costa LdCM, Hespanhol Junior LC, Lopes AD, Costa LOP (2014 Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review. Journal of Physiotherapy 60: 31–39

  3. Synergistic reinforcement of highly oriented poly(propylene) tapes by sepiolite nanoclay

    NARCIS (Netherlands)

    Bilotti, E.; Deng, H.; Zhang, R.; Lu, D.; Bras, W.; Fischer, H.R.; Peijs, T.

    2010-01-01

    This paper reports the properties of highly oriented nanocomposite tapes based on isotactic PP and needle-like sepiolite nanoclay, obtained by a solid state drawing process. The intrinsic 1D character of sepiolite allows its exploitation in 1D objects, such as oriented polymer fibres and tapes,

  4. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    Directory of Open Access Journals (Sweden)

    Brendon A. Parsons

    2015-06-01

    Full Text Available In a PTFE tape phase-vanishing reaction (PV-PTFE, a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design.

  5. Final report: High current capacity high temperature superconducting film based tape for high field magnets

    International Nuclear Information System (INIS)

    Ying Xin

    2000-01-01

    The primary goal of the program was to establish the process parameters for the continuous deposition of high quality, superconducting YBCO films on one meter lengths of buffered RABiTS tape using MOCVD and to characterize the potential utility of the resulting tapes in high field magnet applications

  6. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Directory of Open Access Journals (Sweden)

    Sara Abolahrari Shirazi

    2018-01-01

    Full Text Available Background: Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. Materials and Methods: The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20–45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups (n = 15. Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. Results: No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups (P > 0.05. However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention (P < 0.01. Conclusion: Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  7. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    Science.gov (United States)

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  8. Elongated grains in cube textured nickel substrate tapes and flat wires

    International Nuclear Information System (INIS)

    Eickemeyer, J; Gueth, A; Holzapfel, B

    2008-01-01

    Cube textured nickel substrate tapes and flat wires with an increased grain aspect ratio were prepared from nickel micro-alloyed with silver plus yttrium and silver, respectively. Whereas the maximum grain aspect ratio for the tapes was about 6, this value reached up to 14 for the flat wires

  9. Effect of crystallization rate of initial alloy on magnetic properties of amorphous tape

    International Nuclear Information System (INIS)

    Roshchin, V.E.; Gribanov, V.P.; Shcherbakov, D.G.; Gun'kin, V.E.

    1994-01-01

    An investigation is made into mechanism and character of cooling rate effect when castings crytallizing on magnetic properties of rapidly quenched amorphous tape of Fe 78 B 12 Si 9 Ni 1 alloy. The increase of cooling rate and holding at heat for superheated melt is shown to result in a rise of Curie point of amorphous tape

  10. Texture gradients in Fe-sheathed ex situ produced MgB2 tapes

    International Nuclear Information System (INIS)

    Lezza, P; Gladyshevskii, R; Abaecherli, V; Fluekiger, R

    2006-01-01

    Superconducting Fe-sheathed MgB 2 monofilamentary tapes have been fabricated by the powder-in-tube technique, varying the particle size of the starting MgB 2 powder and applying either cold or hot rolling during the last deformation process. Measurements of the critical current density J c with the magnetic field applied parallel or perpendicular to the tape surface revealed a pronounced anisotropy for the cold rolled tapes, which was found to increase with increasing particle size and magnetic field strength. The microstructural origin of the J c anisotropy was confirmed by means of x-ray diffraction performed on the filaments after mechanical removal of the sheath. The local texture was studied in a series of diffraction patterns collected at different distances from the filament centre, removing each time some 25 μm of the filament thickness. In the cold rolled tapes, the average orientation of the MgB 2 grains was found to approach a preferred orientation with the crystallographic c-axis perpendicular to the tape surface, near the interface with the sheath; however, the misalignment angle increased towards the centre of the tape. In the hot rolled tapes, for which no J c anisotropy was observed, the grains were found to be approximately randomly oriented. Roughness measurements performed on the side of the Fe sheath in contact with the MgB 2 filament are in agreement with the difference in texture observed for cold and hot rolled tapes

  11. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  12. Effects of Managers’ Work Motivation and Networking Activity on Their Reported Levels of External Red Tape

    NARCIS (Netherlands)

    Torenvlied, R.; Akkerman, A.

    2012-01-01

    This study brings together two perspectives on managers’ reported levels of red tape. The work motivation perspective explains how managers’ characteristics, such as work engagement (alienation) or commitment, affect their reported levels of red tape. The external control perspective explains how

  13. Computer tape library for collective dose assessments in the European Community

    International Nuclear Information System (INIS)

    Jones, J.A.; Kelly, G.N.

    1981-01-01

    A computer tape library has been established which can readily be applied to enable calculations to be made of the collective dose to the population of the European Community from radioactive effluent discharges within the EC. The background to the development of the tape library and details of its contents, method of application and availability are summarised in this note. (author)

  14. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  15. Study on Fabrication of Ni-5 at.%W Tapes for Coated Conductors from Cylinder Ingots

    DEFF Research Database (Denmark)

    Ma, L.; Suo, H. L.; Yue, Zhao

    2015-01-01

    Ni-5 at.%W (Ni5W) tapes with a strong cube texture were fabricated using the RABiTS technique and by starting from cylindrical shaped ingots. In contrast to a conventional cuboid-shaped ingot, a cylinder shaped ingot has no anisotropy along the axial direction and the resulting tape will therefore...

  16. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    International Nuclear Information System (INIS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-01-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour. (paper)

  17. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    Science.gov (United States)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  18. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  19. The effect of rigid taping with tension on mechanical displacement of the skin and change in pain perception.

    Science.gov (United States)

    Chen, Shu-Mei; Lo, Sing Kai; Cook, Jill

    2018-04-01

    To investigate the effect of rigid taping that induces mechanical displacement of the skin on pain perception. Single group experiment design with repeated measures. Twenty-three active healthy volunteers (12 men and 11 women) participated in the study. All participants received three different taping procedures: no tape, taping with tension, and taping without tension. The order of three taping conditions was randomised. Skin displacement was measured during taping with tension. A pressure algometer was used to measure the level of pain perception once before taping, and again after each taping condition, in one testing session. The participants were blind to the values of their pressure pain threshold (PPT) during the experimental period. The mean±SD skin displacement in the condition of taping with tension was 2.58±0.49cm. There were significant differences in PPT between taping with tension and taping without tension (mean difference (mean diff)±standard error (SE) 36.43±4.22kPa, p=0.000) and no tape (mean diff±SE 44.31±3.13kPa, p=0.000). No significant difference in PPT between no tape and taping without tension was found (mean diff±SE 7.88±2.83kPa, p=0.067). Taping with tension increases the threshold of pressure pain perception. Therefore, stretch and compression caused by rigid taping with tension could disturb the nociceptive signal transmission and alter pain perception. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Generation of ultra-sound during tape peeling

    KAUST Repository

    Marston, Jeremy O.; Riker, Paul W.; Thoroddsen, Sigurdur T

    2014-01-01

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  1. Continuous welding of unidirectional fiber reinforced thermoplastic tape material

    Science.gov (United States)

    Schledjewski, Ralf

    2017-10-01

    Continuous welding techniques like thermoplastic tape placement with in situ consolidation offer several advantages over traditional manufacturing processes like autoclave consolidation, thermoforming, etc. However, still there is a need to solve several important processing issues before it becomes a viable economic process. Intensive process analysis and optimization has been carried out in the past through experimental investigation, model definition and simulation development. Today process simulation is capable to predict resulting consolidation quality. Effects of material imperfections or process parameter variations are well known. But using this knowledge to control the process based on online process monitoring and according adaption of the process parameters is still challenging. Solving inverse problems and using methods for automated code generation allowing fast implementation of algorithms on targets are required. The paper explains the placement technique in general. Process-material-property-relationships and typical material imperfections are described. Furthermore, online monitoring techniques and how to use them for a model based process control system are presented.

  2. Generation of ultra-sound during tape peeling

    KAUST Repository

    Marston, Jeremy O.

    2014-03-21

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  3. Adhesive tape exfoliation: Why it works for graphene

    Science.gov (United States)

    Bohr, Jakob

    2015-03-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful. In particular on the nature of the surprisingly small number of repetitive steps that are needed in order to obtain a single-layer slab. Two frameworks for exfoliation are investigated: parallel exfoliation involving repetitive simultaneous cleaving, the other, serial exfoliation, which involves the repetitive cleaving of a single chunk of graphite. For both cases, parallel and serial exfoliation, it is investigated how many generations of cleavages are needed. An approximate model with the probability distribution expressed as a simple closed form is presented and compared with the simulations.

  4. Magnetic imaging of superconducting tapes to determine current flow

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G. W. (Geoffrey W.); Hawley, M. E. (Marilyn E.); Foltyn, S. R. (Stephen R.); Mueller, F. M. (Fred M.)

    2001-01-01

    We have developed a magnetic imaging system that uses magnetoresistive read heads from computer hard disk drives to map the transport-current-induced magnetic field at the surface of superconducting tapes at liquid nitrogen temperature. Transport current pathways are determined from the 2-dimensional magnetic field maps using established inversion schemes. We examined the current flow in pulsed-laser-deposited YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} a films patterned on single crystal SrTiO{sub 3} substrates and on a textured yttria-stabilized-zirconia layer deposited on an Inconel ribbon by ion beam assisted deposition. The transport current densities in all cases were consistent with the Critical State Model. For the Inconel-based sample, the transport current density maps have allowed us to observe defects and determine the region that limits the current carrying capacity of the structure.

  5. Evolution of Archival Storage (from Tape to Memory)

    Science.gov (United States)

    Ramapriyan, Hampapuram K.

    2015-01-01

    Over the last three decades, there has been a significant evolution in storage technologies supporting archival of remote sensing data. This section provides a brief survey of how these technologies have evolved. Three main technologies are considered - tape, hard disk and solid state disk. Their historical evolution is traced, summarizing how reductions in cost have helped being able to store larger volumes of data on faster media. The cost per GB of media is only one of the considerations in determining the best approach to archival storage. Active archives generally require faster response to user requests for data than permanent archives. The archive costs have to consider facilities and other capital costs, operations costs, software licenses, utilities costs, etc. For meeting requirements in any organization, typically a mix of technologies is needed.

  6. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  7. A randomised controlled trial of ultrasound-guided blockade of the saphenous nerve and the posterior branch of the obturator nerve for postoperative analgesia after day-case knee arthroscopy

    DEFF Research Database (Denmark)

    Westergaard, B; Jensen, K; Lenz, K

    2014-01-01

    The purpose of this study was to investigate the effects of blockade of the saphenous nerve and the posterior branch of the obturator nerve in addition to a standard analgesic regimen for patients discharged the same day after knee arthroscopy. The primary outcome was knee pain on flexion during...

  8. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    Science.gov (United States)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  9. The effect of tape casting operational parameters on the quality of adjacently graded ceramic film

    DEFF Research Database (Denmark)

    Bulatova, Regina; Gudik-Sørensen, Mads; Della Negra, Michela

    2016-01-01

    For small length tape casting of ceramic slurries varying green film thickness is often a problem. To optimise this, the following parameters were investigated: single blade, double blade, using a pump system and a modelled speed change mode have been analysed. Advantages and limitations of every...... method are described here. The tape casting experiments were built to be generic in order to allow the control of various processing conditions. From these results, the single-blade technique was chosen for a study of side-by-side tape casting. The influence of the geometric parameters of partitioning...... the casting tank into chambers, on the quality of graded tape was studied. Tape casting experiments at different speeds and partition tongue lengths in combination with rheological tests revealed that high casting speeds and absence of the partition under the blade are detrimental to the formation...

  10. Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Yull; Park, Young Gun; Lee, Woo Seung; Jo, Hyun Chul; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Yoon, Yong Soo [Shin Ansan University, Ansan (Korea, Republic of)

    2014-03-15

    Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

  11. Development of a test procedure for cryogenic adhesive tapes; Entwicklung einer Testprozedur fuer kryogene Klebebaender

    Energy Technology Data Exchange (ETDEWEB)

    Funke, Thomas; Haberstroh, Christoph [TU Dresden (Germany). Bitzer-Professur fuer Kaelte-, Kryo- und Kompressorentechnik; Mayrhofer, Robert; Stipsitz, Johannes [RUAG Space GmbH, Wien (Austria)

    2016-07-01

    At cryostats and dewars for lowest temperatures - especially in connection with liquid-helium cooling at around 4 K, as well at the most applications of the superconductivity - often joints and shutters on the base of low-temperature suited adhesive tapes are required. A current method for the thermal isolation of cold surfaces is their covering with highly reflecting aluminium foils, which are fastened by adhesive aluminium tapes. Selection, usage, and reliability estimation of presumably suited adhesive tapes respectively aluminium tapes occurs presently rather heuristically. A corresponding testing apparature for the measurement of the maximal pulling force was developed and tested by means of a series of test measurements. The testing set-up and measurement results for the validation of the measurement concept with adhesive aluminium tapes are presented in this contribution.

  12. Uranium doping and neutron irradiation of Bi-2223 superconduction tapes for improved critical current density

    International Nuclear Information System (INIS)

    Moss, S.D.; Wang, W.G.; Dou, S.X.; Weinstein, R.

    1998-01-01

    It is demonstrated that a combination of neutron irradiation with uranium doping introduce fission tracks through a Bi-2223 tape which act as effective pinning centres, leading to a substantial increase in critical current. Preliminary data suggests that the combination of uranium doping and neutron irradiation produces improved flux pinning in Bi-2223 tapes over neutron irradiation alone. Before irradiation, SEM, DTA and XRD analyses were performed on the tapes. Both before and after irradiation the trapped maximum magnetic flux was measured at 77K. Before neutron irradiation, uranium doping has no effect on critical current. Preliminary SEM data suggested that the uranium is homogeneously distributed throughout the oxide core of the tape. The presence of 2212 and other secondary phases in the doped tapes suggest further refinement of the sintering procedure is necessary. (authors)

  13. POSTOPERATIVE URINARY RETENTION AND EARLY REPOSITION OF TENSION-FREE VAGINAL TAPE

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2003-12-01

    Full Text Available Background. The purpose of this article is to show a possible method of treatment of postoperative urinary retention after an initial tension-free vaginal tape.Methods. From December 1999 to May 2003 we performed one hundred TVT procedures at our department, among them five women had postoperative urinary retention evaluated with catheterization. Revision and reposition of tension-free vaginal tape were performed if retention of urine was over 100 ml.Results. Urinary retention after an initial tension-free vaginal tape was successfully treated by early reposition of tension-free vaginal tape. This resulted in immediate residualfree voiding and continence, which remained unchanged at 6 week and 3 month follow-up.Conclusions. Postoperative urinary retention may be treated by reposition instead of dissection or elongation of the tension-free vaginal tape.

  14. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    Science.gov (United States)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  15. Ankle taping does not impair performance in jump or balance tests.

    Science.gov (United States)

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  16. VHS-tape system for general purpose computer. For next generation mass storage system

    International Nuclear Information System (INIS)

    Ukai, K.; Takano, M.; Shinohara, M.; Niki, K.; Suzuki, Y.; Hamada, T.; Ogawa, M.

    1994-07-01

    Mass storage is one of the key technology of next generation computer system. A huge amount of data is produced on a field of particle and nuclear physics. These data are raw data of experiments, analysis data, Monte Carlo simulations data, etc. We search a storage device for these data at the point of view of capacity, price, size, transfer speed, etc. We have selected a VHS-tape (12.7 mm-tape, helical scan) from many storage devices. Characteristics of the VHS-tape are as follows; capacity of 14.5 GB, size of 460 cm 3 , price of 1,000 yen (S-VHS tape for video use), and 1.996 MB/sec transfer speed at a sustained mode. Last year, we succeeded to operate the VHS-tape system on a workstation as a I/O device with read/write speed of 1.5 MB/sec. We have tested a VHS-tape system by connecting to the channel of the general purpose computer (Fujitsu M-780/10S) in our institute. We obtained a read and write speeds of 1.07 MB/sec and 1.72 MB/sec by FORTRAN test programs, respectively. Read speeds of an open reel tape and a 3480 type cassete tape by the same test programs are 1.13 MB/sec and 2.54 MB/sec, respectively. Speeds of write operation are 1.09 MB/sec and 2.54 MB/sec for the open reel and 3480 cassete tape, respectively. A start motion of the VHS-tape for read/write operations needs about 60 seconds. (author)

  17. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    Science.gov (United States)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  18. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  19. Anisotropy of the critical current in MgB2 tapes made of high energy milled precursor powder

    DEFF Research Database (Denmark)

    Hässler, W.; Kovac, P.; Eisterer, M.

    2010-01-01

    For applications of MgB2 wires or tapes, high critical currents in high magnetic fields are essential. By using tapes in superconducting coils the anisotropic behaviour of the critical current, i.e. the dependence on the direction of the external field in relation to the tape surface, has to be t...

  20. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Bulatova, Regina; Tok, A. I Y

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casti...

  1. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    Science.gov (United States)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  2. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  3. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    Science.gov (United States)

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  4. Fabrication and properties of Ag-Bi2223 tapes with resistive barriers for filament decoupling

    International Nuclear Information System (INIS)

    Inada, Ryoji; Fukumoto, Yohei; Yasunami, Taeko; Nakamura, Yuichi; Oota, Akio; Li Chengshang; Zhang Pingxiang

    2007-01-01

    In this paper, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 + Bi2212 as interfilamentary resistive barriers to suppress the electromagnetic coupling among the filaments under AC external magnetic field. The tapes with thin barrier layers of Ca 2 CuO 3 + 30 wt% Bi2212 around the filaments were prepared by using a standard powder-in-tube (PIT) method. The outside surface of monocore Ag-sheathed rods was coated by barrier materials. Then, the several coated monocore wires were stacked and packed into another Ag or Ag-Mg alloy tube. The packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. For the characterization of tapes, X-ray diffraction measurements were performed to investigate the phase formation inside the filaments. The uniformity of transport properties (J c ) for barrier tapes were evaluated on the order of several metre lengths and compared with the result for the tapes without barriers. Finally, AC loss characteristics under AC parallel transverse magnetic field were investigated to examine the effect of introducing the barriers on the filament decoupling

  5. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  6. ANKLE TAPING DOES NOT IMPAIR PERFORMANCE IN JUMP OR BALANCE TESTS

    Directory of Open Access Journals (Sweden)

    Javier Abián-Vicén

    2008-09-01

    Full Text Available This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96. The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed

  7. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  8. Degradation characteristics of 2G HTS tapes with respect to an electrical breakdown

    International Nuclear Information System (INIS)

    Kang, Jong O; Lee, On You; Mo, Young Kyu; Kim, Jun Il; Bang, Seung Min; Lee, Hong Seok; Kang, Hyoung Ku; Lee, Jae Hun; Jang, Cheol Yeong

    2015-01-01

    The electrical insulation design for a superconducting coil system is important for developing high voltage superconducting apparatuses. Also, the degraded characteristics of superconducting tapes due to an electrical breakdown should be considered for superconducting coils design. In this study, the degradation characteristics of 2G high temperature superconducting (HTS) tapes were studied with respect to electrical breakdown tests. The degradation tests of 2G HTS tapes were performed with various stabilizer materials. The degradation characteristics of 2G HTS tapes such as critical current(Ic) and index number were observed by performing electrical breakdown tests. It was found that the characteristics such as Ic and index number can be degraded by an electrical breakdown. Moreover, it was concluded that the degradation characteristics of 2G HTS tapes were affected by a stabilizer material and applied breakdown voltage. The cross sectional view of 2G HTS tapes was observed by using a scanning electron microscope (SEM). As results, it is found that the degradation characteristics of 2G HTS tapes are concerned with hardness and electrical resistivity of stabilizer layers

  9. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    Science.gov (United States)

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  10. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  11. Kinesio Taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-06-01

    Full Text Available Question: For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Design: Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. Participants: 148 participants with chronic non-specific low back pain. Intervention: Experimental group participants received eight sessions (over four weeks of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral. Control group participants received eight sessions (over four weeks of Kinesio Taping with no tension, creating no convolutions. Outcome measures: The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Results: Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD–0.4 points, 95% CI–1.3 to 0.4 or disability (MD–0.3 points, 95% CI–1.9 to 1.3 at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5 at four weeks. No significant between-group differences were observed for the other secondary outcomes. Conclusion: Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Trial registration: Brazilian Registry of Clinical Trials, RBR-7ggfkv. [Parreira PCS, Costa LCM, Takahashi R, Hespanhol Junior LC, da Luz Junior MA, da Silva TM, Costa LOP

  12. Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

    Science.gov (United States)

    Wohl, Christopher; Palmieri, Frank L.; Forghani, Alireza; Hickmott, Curtis; Bedayat, Houman; Coxon, Brian; Poursartip, Anoush; Grimsley, Brian

    2017-01-01

    NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly

  13. Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Mean, Byoung Jean; Lee, Jae Hun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-12-15

    The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current (I{sub c}) was measured at 77 K and self-field. Depending on whether the I{sub c} of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of I{sub c}, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.

  14. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    Science.gov (United States)

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    Science.gov (United States)

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  16. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  17. Stage III Community-based Efficacy Trial for Mothering From the Inside Out

    Science.gov (United States)

    2018-01-05

    Addiction; Substance Abuse Drug Chronic; Child Neglect; Child Neglect Emotional; Child Abuse; Parenting; Parent-Child Problem; Parent-Child Relations; Parent / Child Problem; Parenteral Drug Abuse; Parents

  18. The Inside, Out: Diaries as Entry Points to Historical Perspective-Taking

    Science.gov (United States)

    Lemisko, Lynn

    2010-01-01

    Diaries can serve as meaningful entry points for advancing historical consciousness and develop historical thinking (Seixas, 2002) because they can connect readers/learners with the diverse emotions, thoughts and motivations of the people who wrote them in particular times and particular places. According to philosopher and historian, R.G.…

  19. Turning Ideologies inside Out: Developing Young Readers' Empathy for Critical Voices in Narrative Fiction

    Science.gov (United States)

    Pereira, Íris Susana Pires; Campos, Ângela

    2014-01-01

    This article is located at the crossroads between two distinctive human traits, empathy and rational thought, with narrative emerging as a particularly powerful means to enable young readers to bring them together. Specifically, we discuss the role that critical literary exegesis plays in the development of empathic consciousness in literary…

  20. Organizational Transformation from the Inside Out: Reinventing the MIT Center for Organizational Learning.

    Science.gov (United States)

    Clanon, Jeff

    1999-01-01

    The 2-year process by which the Massachusetts Institute of Technology's Center for Organizational Learning transformed into the self-governed Society for Organizational Learning illustrates new ways of conceiving organizations, the capabilities required for change, and critical elements of the process: diverse representation, grounding in business…