WorldWideScience

Sample records for t1-weighted-space dark blood

  1. Breath-hold dark-blood T{sub 2}-weighted MR imaging of the heart. Estimation of optimum preset repetition time

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Toshiharu; Yamada, Naoaki; Yamasaki, Hidetoshi; Kita, Yoshinobu; Fujii, Hiroshi [National Cardiovascular Center, Suita, Osaka (Japan)

    1999-03-01

    It has recently become possible to obtain T{sub 2}-weighted images using turbo spin echo with a preparation pulse to inhibit the signal from flowing blood (dark blood turbo spin echo: DB-TSE) during breath holding. In order to obtain higher-quality T{sub 2}-weighted images of the heart, we assessed the optimum preset repetition time (TR preset), the interval between the dark blood preparation pulse and the end of data acquisition on DB-TSE. DB-TSE left ventricular short-axis images were obtained with varying TR presets in eight volunteers. Signal intensity was measured for the myocardium and blood in the left ventricular cavity, and the signal intensity ratio of myocardium to blood was calculated. The optimum TR preset was determined so as to give the highest signal intensity ratio of myocardium to blood. A comparison was made of the myocardium-to-blood ratios between the eight volunteers and nine patients. The optimum TR preset changed according to the cardiac cycle. By using the optimum TR preset, we obtained the peak signal intensity ratios in the volunteers and the patients. By using DB-TSE with the optimum TR preset for the cardiac cycle, we can obtain better quality T{sub 2}-weighted images of the heart. (author)

  2. Cardiac MRI. T2-mapping versus T2-weighted dark-blood TSE imaging for myocardial edema visualization in acute myocardial infarction

    International Nuclear Information System (INIS)

    Nassenstein, K.; Nensa, F.; Schlosser, T.; Umutlu, L.; Lauenstein, T.; Bruder, O.; Maderwald, S.; Ladd, M.E.

    2014-01-01

    Purpose: To assess the diagnostic accuracy of T2 mapping for the detection of myocardial edema in acute myocardial infarction (AMI), and to compare this diagnostic accuracy with that of the current standard for myocardial edema imaging, which is T2w dark-blood TSE imaging. Materials and Methods: 29 patients with AMI were examined at 1.5 T. For the visualization of myocardial edema, T2 maps, calculated from three T2w SSFP images, and T2w dark-blood TSE images were acquired in standard short- and long-axis views. Cine SSFP images were acquired for the analysis of left ventricular (LV) function and late gadolinium enhancement images (LGE) for the visualization of myocardial necrosis. The T2 maps as well as the T2w dark-blood TSE images were evaluated twice independently from the cine SSFP and LGE images. The presence or absence of myocardial edema was rated visually for each LV segment. As the standard of reference, the infarct zone was defined based on the cine SSFP and the LGE images. Results: In this segment-based analysis, T2 mapping showed a sensitivity of 82 % and a specificity of 94 % for the detection of edema in the infarct zone. T2w dark-blood TSE imaging revealed a sensitivity of 50 % and a specificity of 98 %. T2 mapping showed a higher intra-rater agreement compared to T2w dark-blood TSE imaging (κ: 0.87 vs. 0.76). Conclusions: T2 mapping allows for the visualization of myocardial edema in AMI with a high sensitivity and specificity, and features better diagnostic accuracy in terms of a higher sensitivity compared to T2w dark-blood TSE imaging. (orig.)

  3. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  4. Dark matter search with XENON1T

    NARCIS (Netherlands)

    Aalbers, J.

    2018-01-01

    Most matter in the universe consists of 'dark matter' unknown to particle physics. Deep underground detectors such as XENON1T attempt to detect rare collisions of dark matter with ordinary atoms. This thesis describes the first dark matter search of XENON1T, how dark matter signals would appear in

  5. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  6. Measurement of brain oxygenation changes using dynamic T1-weighted imaging

    DEFF Research Database (Denmark)

    Haddock, Bryan; Larsson, Henrik B W; Hansen, Adam E

    2013-01-01

    Magnetic resonance imaging (MRI) has proven useful in evaluating oxygenation in several types of tissue and blood. This study evaluates brain tissue oxygenation changes between normoxia and hyperoxia in healthy subjects using dynamic T1 and T2*-weighted imaging sequences. The change in FiO2 induced...... by hyperoxia caused a significant decrease in T1. A model to determine changes in tissue oxygen tension from the T1-weighted MRI signal is presented based on previous findings that T1 is sensitive to oxygen tension whereas T2* is sensitive to blood saturation. The two sequences produce results with different...... regional and temporal dynamics. These differences combined with results from simulations of the T1 signal intensities, indicate an increase in extravascular oxygen tension during hyperoxia. This study concludes that T1 and T2* responses to FiO2 serve as independent biomarkers of oxygen physiology...

  7. The space-time of dark-matter

    International Nuclear Information System (INIS)

    Dey, Dipanjan

    2015-01-01

    Dark-matter is a hypothetical matter which can't be seen but around 27% of our universe is made of it. Its distribution, evolution from early stage of our universe to present stage, its particle constituents all these are great unsolved mysteries of modern Cosmology and Astrophysics. In this talk I will introduce a special kind of space-time which is known as Bertrand Space-time (BST). I will show this space-time interestingly shows some dark-matter properties like- flat velocity curve, density profile of Dark-matter, total mass of Dark matter-halo, gravitational lensing etc, for that reason we consider BST is seeded by Dark-matter or it is a space-time of Dark-matter. At last I will show using modified gravity formalism the behaviour of the equation of state parameter of Dark-matter and the behaviour of the Newton's gravitational constant in the vicinity of the singularity. (author)

  8. Consumption of High-Polyphenol Dark Chocolate Improves Endothelial Function in Individuals with Stage 1 Hypertension and Excess Body Weight

    Directory of Open Access Journals (Sweden)

    Lívia de Paula Nogueira

    2012-01-01

    Full Text Available Background. Hypertension and excess body weight are important risk factors for endothelial dysfunction. Recent evidence suggests that high-polyphenol dark chocolate improves endothelial function and lowers blood pressure. This study aimed to evaluate the association of chocolate 70% cocoa intake with metabolic profile, oxidative stress, inflammation, blood pressure, and endothelial function in stage 1 hypertensives with excess body weight. Methods. Intervention clinical trial includes 22 stage 1 hypertensives without previous antihypertensive treatment, aged 18 to 60 years and presents a body mass index between 25.0 and 34.9 kg/m2. All participants were instructed to consume 50 g of chocolate 70% cocoa/day (2135 mg polyphenols for 4 weeks. Endothelial function was evaluated by peripheral artery tonometry using Endo-PAT 2000 (Itamar Medical. Results. Twenty participants (10 men completed the study. Comparison of pre-post intervention revealed that (1 there were no significant changes in anthropometric parameters, percentage body fat, glucose metabolism, lipid profile, biomarkers of inflammation, adhesion molecules, oxidized LDL, and blood pressure; (2 the assessment of endothelial function through the reactive hyperemia index showed a significant increase: 1.94 ± 0.18 to 2.22 ± 0.08, P=0.01. Conclusion.In individuals with stage 1 hypertension and excess body weight, high-polyphenol dark chocolate improves endothelial function.

  9. Mirror dark matter will be confirmed or excluded by XENON1T

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, J.D., E-mail: j.clarke5@pgrad.unimelb.edu.au; Foot, R., E-mail: rfoot@unimelb.edu.au

    2017-03-10

    Mirror dark matter, where dark matter resides in a hidden sector exactly isomorphic to the standard model, can be probed via direct detection experiments by both nuclear and electron recoils if the kinetic mixing interaction exists. In fact, the kinetic mixing interaction appears to be a prerequisite for consistent small scale structure: Mirror dark matter halos around spiral galaxies are dissipative – losing energy via dark photon emission. This ongoing energy loss requires a substantial energy input, which can be sourced from ordinary supernovae via kinetic mixing induced processes in the supernova's core. Astrophysical considerations thereby give a lower limit on the kinetic mixing strength, and indeed lower limits on both nuclear and electron recoil rates in direct detection experiments can be estimated. We show here that potentially all of the viable parameter space will be probed in forthcoming XENON experiments including LUX and XENON1T. Thus, we anticipate that these experiments will provide a definitive test of the mirror dark matter hypothesis.

  10. Mirror dark matter will be confirmed or excluded by XENON1T

    Directory of Open Access Journals (Sweden)

    J.D. Clarke

    2017-03-01

    Full Text Available Mirror dark matter, where dark matter resides in a hidden sector exactly isomorphic to the standard model, can be probed via direct detection experiments by both nuclear and electron recoils if the kinetic mixing interaction exists. In fact, the kinetic mixing interaction appears to be a prerequisite for consistent small scale structure: Mirror dark matter halos around spiral galaxies are dissipative – losing energy via dark photon emission. This ongoing energy loss requires a substantial energy input, which can be sourced from ordinary supernovae via kinetic mixing induced processes in the supernova's core. Astrophysical considerations thereby give a lower limit on the kinetic mixing strength, and indeed lower limits on both nuclear and electron recoil rates in direct detection experiments can be estimated. We show here that potentially all of the viable parameter space will be probed in forthcoming XENON experiments including LUX and XENON1T. Thus, we anticipate that these experiments will provide a definitive test of the mirror dark matter hypothesis.

  11. Predictive value of PWI for blood supply and T1-spin echo MRI for consistency of pituitary adenoma

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zengyi; He, Wenqiang; Zhao, Yao; Zhang, Qilin; Li, Shiqi; Wang, Yongfei [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China); Shanghai Pituitary Tumor Center, Shanghai (China); Yuan, Jie; Wu, Yue; Yao, Zhenwei [Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China); Chen, Hong [Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China)

    2016-01-15

    It is a common view that consistency and blood supply of pituitary adenoma (PA) can influence the surgical effect. The aim of this study was to determine whether MRI signal intensity (SI) was correlated to the consistency or blood supply of pituitary macroadenoma. Forty eight pituitary macroadenoma patients were underwent preoperative MRI, including precontrast and contrast-enhanced (CE) T1-spin echo (T1-SE) imaging, CE-sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) imaging, and perfusion-weighted imaging (PWI). The tumor consistency and blood supply were determined by neurosurgeons. The expression of collagen IV and MIB-1 was detected with immunohistology. The correlation of the relative SI (rSI) values (tumor to normal frontal white matter SI) and PWI data to the tumor consistency, blood supply, and the expression level of collagen IV and MIB-1 was statistically studied by Kruskal-Wallis rank test (K-W test). A significant correlation was observed between the tumor consistency and the rSI on precontrast T1-SE imaging (P = 0.004) but not on CE T1-SE and CE SPACE imaging. The expression of collagen IV was also significantly associated with rSI on T1-SE imaging (P = 0.010). The blood supply was correlated with the relative CBV (rCBV) (P = 0.030). In addition, the expression of MIB-1 was correlated with rSI of CE T1-SE imaging (P = 0.007). Our results suggest that T1-SE imaging may be a simple and useful method for predicting consistency of PA. CBV value can provide helpful information for assessing the blood supply of pituitary macroadenoma. (orig.)

  12. The XENON1T dark matter experiment

    Science.gov (United States)

    Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Antunes, B.; Arneodo, F.; Balata, M.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Chiarini, A.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Corrieri, R.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Gangi, P. Di; Giovanni, A. Di; Diglio, S.; Disdier, J.-M.; Doets, M.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Front, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Giboni, K.-L.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; James, A.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Maier, R.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orlandi, D.; Othegraven, R.; Pakarha, P.; Parlati, S.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M.-C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Saldanha, R.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stern, M.; Stein, A.; Tatananni, D.; Tatananni, L.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Walet, R.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.

    2017-12-01

    The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.

  13. The XENON1T dark matter experiment

    International Nuclear Information System (INIS)

    Aprile, E.; Anthony, M.; De Perio, P.; Gao, F.; Giboni, K.L.; Goetzke, L.W.; Greene, Z.; Lin, Q.; Plante, G.; Rizzo, A.; Stern, M.; Tatananni, D.; Zhang, Y.; Aalbers, J.; Breur, P.A.; Brown, A.; Colijn, A.P.; Decowski, M.P.; Doets, M.; Hogenbirk, E.; Tiseni, A.; Walet, R.; Agostini, F.; Alfonsi, M.; Geis, C.; Grignon, C.; Oberlack, U.; Othegraven, R.; Scheibelhut, M.; Schindler, S.; Amaro, F.D.; Antunes, B.; Cardoso, J.M.R.; Lopes, J.A.M.; Santos, J.M.F. dos; Silva, M.; Arneodo, F.; Benabderrahmane, M.L.; Di Giovanni, A.; Maris, I.; Balata, M.; Bruno, G.; Corrieri, R.; Disdier, J.M.; Rosso, A.G.; Molinario, A.; Orlandi, D.; Parlati, S.; Tatananni, L.; Wang, Z.; Barrow, P.; Baudis, L.; Franco, D.; Galloway, M.; James, A.; Kazama, S.; Kessler, G.; Kish, A.; Maier, R.; Mayani, D.; Pakarha, P.; Piastra, F.; Wulf, J.; Bauermeister, B.; Calven, J.; Conrad, J.; Ferella, A.D.; Moraa, K.; Pelssers, B.; Berger, T.; Brown, E.; Piro, M.C.; Breskin, A.; Budnik, R.; Duchovni, E.; Front, D.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Manfredini, A.; Priel, N.; Bruenner, S.; Cichon, D.; Eurin, G.; Hasterok, C.; Lindner, M.; Undagoitia, T.M.; Pizzella, V.; Rauch, L.; Rupp, N.; Schreiner, J.; Simgen, H.; Wack, O.; Buetikofer, L.; Coderre, D.; Kaminsky, B.; Schumann, M.; Sivers, M. von; Chiarini, A.; Di Gangi, P.; Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M.; Cussonneau, J.P.; Diglio, S.; Masbou, J.; Micheneau, K.; Persiani, R.; Thers, D.; Fei, J.; Lombardi, F.; Ni, K.; Ye, J.; Fieguth, A.; Huhmann, C.; Murra, M.; Rosendahl, S.; Vargas, M.; Weinheimer, C.; Wittweg, C.; Fulgione, W.; Grandi, L.; Saldanha, R.; Shockley, E.; Tunnell, C.; Upole, N.; Lindemann, S.; Messina, M.; Naganoma, J.; Shagin, P.; Pienaar, J.; Garcia, D.R.; Reichard, S.; Lavina, L.S.; Stein, A.; Wang, H.; Trinchero, G.; Wei, Y.

    2017-01-01

    The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented. (orig.)

  14. The XENON1T dark matter experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, E.; Anthony, M.; De Perio, P.; Gao, F.; Giboni, K.L.; Goetzke, L.W.; Greene, Z.; Lin, Q.; Plante, G.; Rizzo, A.; Stern, M.; Tatananni, D.; Zhang, Y. [Columbia University, Physics Department, New York, NY (United States); Aalbers, J.; Breur, P.A.; Brown, A.; Colijn, A.P.; Decowski, M.P.; Doets, M.; Hogenbirk, E.; Tiseni, A.; Walet, R. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Agostini, F. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); University of Bologna, Department of Physics and Astrophysics (Italy); INFN-Bologna (Italy); Alfonsi, M.; Geis, C.; Grignon, C.; Oberlack, U.; Othegraven, R.; Scheibelhut, M.; Schindler, S. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Amaro, F.D.; Antunes, B.; Cardoso, J.M.R.; Lopes, J.A.M.; Santos, J.M.F. dos; Silva, M. [University of Coimbra, LIBPhys, Department of Physics, Coimbra (Portugal); Arneodo, F.; Benabderrahmane, M.L.; Di Giovanni, A.; Maris, I. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Balata, M.; Bruno, G.; Corrieri, R.; Disdier, J.M.; Rosso, A.G.; Molinario, A.; Orlandi, D.; Parlati, S.; Tatananni, L.; Wang, Z. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Barrow, P.; Baudis, L.; Franco, D.; Galloway, M.; James, A.; Kazama, S.; Kessler, G.; Kish, A.; Maier, R.; Mayani, D.; Pakarha, P.; Piastra, F.; Wulf, J. [University of Zurich, Physik Institut, Zurich (Switzerland); Bauermeister, B.; Calven, J.; Conrad, J.; Ferella, A.D.; Moraa, K.; Pelssers, B. [Stockholm University, AlbaNova, Oskar Klein Centre, Department of Physics, Stockholm (Sweden); Berger, T.; Brown, E.; Piro, M.C. [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy, Troy, NY (United States); Breskin, A.; Budnik, R.; Duchovni, E.; Front, D.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Manfredini, A.; Priel, N. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); Bruenner, S.; Cichon, D.; Eurin, G.; Hasterok, C.; Lindner, M.; Undagoitia, T.M.; Pizzella, V.; Rauch, L.; Rupp, N.; Schreiner, J.; Simgen, H.; Wack, O. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Buetikofer, L.; Coderre, D.; Kaminsky, B.; Schumann, M. [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Sivers, M. von [Freiburg Univ. (Germany). Physikalisches Inst.; Bern Univ. (Switzerland). Albert Einstein Center for Fundamental Physics; Cervantes, M.; Lang, R.F.; Masson, D.; Reuter, C. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Chiarini, A.; Di Gangi, P.; Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M. [University of Bologna, Department of Physics and Astrophysics, Bologna (Italy); INFN-Bologna (Italy); Cussonneau, J.P.; Diglio, S.; Masbou, J.; Micheneau, K.; Persiani, R.; Thers, D. [CNRS/IN2P3, Universite de Nantes, SUBATECH, IMT Atlantique, Nantes (France); Fei, J.; Lombardi, F.; Ni, K.; Ye, J. [University of California, Department of Physics, San Diego, CA (United States); Fieguth, A.; Huhmann, C.; Murra, M.; Rosendahl, S.; Vargas, M.; Weinheimer, C.; Wittweg, C. [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Fulgione, W. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Turin (Italy); Grandi, L.; Saldanha, R.; Shockley, E.; Tunnell, C.; Upole, N. [University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Lindemann, S. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Messina, M. [Columbia University, Physics Department, New York, NY (United States); New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Naganoma, J.; Shagin, P. [Rice University, Department of Physics and Astronomy, Houston, TX (United States); Pienaar, J. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Garcia, D.R. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Reichard, S. [University of Zurich, Physik Institut, Zurich (Switzerland); Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Lavina, L.S. [Universite Pierre et Marie Curie, Universite Paris Diderot, CNRS/IN2P3, LPNHE, Paris (France); Stein, A.; Wang, H. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Trinchero, G. [INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Turin (Italy); Wei, Y. [University of Zurich, Physik Institut, Zurich (Switzerland); University of California, Department of Physics, San Diego, CA (United States); Collaboration: XENON Collaboration

    2017-12-15

    The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented. (orig.)

  15. Contrast-enhanced MR imaging of metastatic brain tumor at 3 Tesla. Utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence

    International Nuclear Information System (INIS)

    Komada, Tomohiro; Naganawa, Shinji; Ogawa, Hiroshi

    2008-01-01

    We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T 1 -weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T 1 -weighted spin echo (2D-SE) imaging at 3 T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P 1 -weighted imaging. (author)

  16. Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering

    International Nuclear Information System (INIS)

    Biederer, J.; Reuter, M.; Both, M.; Grimm, J.; Heller, M.; Muhle, C.; Graessner, J.

    2002-01-01

    The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2-weighted TSE. (orig.)

  17. Cosmological viability conditions for f(T) dark energy models

    Energy Technology Data Exchange (ETDEWEB)

    Setare, M.R.; Mohammadipour, N., E-mail: rezakord@ipm.ir, E-mail: N.Mohammadipour@uok.ac.ir [Department of Science, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2012-11-01

    Recently f(T) modified teleparallel gravity where T is the torsion scalar has been proposed as the natural gravitational alternative for dark energy. We perform a detailed dynamical analysis of these models and find conditions for the cosmological viability of f(T) dark energy models as geometrical constraints on the derivatives of these models. We show that in the phase space exists two cosmologically viable trajectory which (i) The universe would start from an unstable radiation point, then pass a saddle standard matter point which is followed by accelerated expansion de sitter point. (ii) The universe starts from a saddle radiation epoch, then falls onto the stable matter era and the system can not evolve to the dark energy dominated epoch. Finally, for a number of f(T) dark energy models were proposed in the more literature, the viability conditions are investigated.

  18. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  19. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  20. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    International Nuclear Information System (INIS)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V.

    2010-01-01

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  1. MR imaging findings of diffuse axonal injury: comparison of T2-weighted gradient images and T1- and T2-weighted spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seo Young; Lee, Ghi Jai; Kim, Jeong Seok; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To compare T2-weighted images with spin-echo T1- and turbo spin-echo (TSE) T2-weighted images in patients with diffuse axonal injury(DAI). Using a 1.0T MR unit, SE T1-, TSE T2-, and and FLASH T2-weighted images were obtained from 69 patients with a history of head trauma. In 18MR images of 17 patients with imaging findings of DAI, T2-weighted images were retrospectively compared with SE T1- and TSE T2-weighted images. The interval between trauma and MR scan varied from 5 days to 24(mean, 11) months. Focusing on the number of lesions, and their location and signal intensity, as weel as associated findings, three images were simultaueously evaluated. In 18 MR images of 17 patients with MR imaging findings of DAI, 21 lesions were detected on T1-weighted images, 28 on TSE T2-weighted images, and 70 on T2-weighted images;the last of these revealed all lesions detected on the other two. Most lesions were hypointense on T1-weighted images(17/21), hyperintense on TSE T2-weighted (21/28), and hypointense on T2-weighted (63/70). Common locations for DAI were the frontal lobe (n=3D35) and corpus callosum (n=3D22). Associated brain injuries were cortical contusion (n=3D5), brainstem injury (n=3D3), deep gray matter injury (n=3D2), and subdural hematoma(n=3D1). In patients with DAI. T2-weighted images can detect more lesions and associated petechial hemorrhage than can TSE T2-weighted images. This modality is thus useful for the evaluation of patients with head trauma.=20.

  2. Fat-suppressed MRI of musculoskeletal infection: fast T2-weighted techniques versus gadolinium-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Miller, T.T.; Randolph, D.A. Jr.; Staron, R.B.; Feldman, F.; Cushin, S.

    1997-01-01

    Purpose. To investigate gadolinium's role in imaging musculoskeletal infection by comparing the conspicuity and extent of inflammatory changes demonstrated on gadolinium-enhanced fat-suppressed T1-weighted images versus fat-suppressed fast T2-weighted sequences. Design. Eighteen patients with infection were imaged in a 1.5-T unit, using frequency-selective and/or inversion recovery fat-suppressed fast T2-weighted images (T2WI) and gadolinium-enhanced frequency-selective fat-suppressed T1-weighted images (T1WI). Thirty-four imaging planes with both a fat-suppressed gadolinium-enhanced T1-weighted sequence and a fat-suppressed T2-weighted sequence were obtained. Comparison of the extent and conspicuity of signal intensity changes was made for both bone and soft tissue in each plane. Results. In bone, inflammatory change was equal in extent and conspicuity on fat-suppressed T2WI and fat-suppressed T1WI with gadolinium in 19 planes, more extensive or conspicuous on T2WI in three planes, and less so on T2WI in two planes. Marrow was normal on all three sequences in 10 cases. In soft tissue, inflammatory change was seen equally well in 20 instances, more extensively or conspicuously on the T2WI in 11 instances, and less so on T2WI in 2 instances. One case had no soft tissue involvement on any of the sequences. Five abscesses and three joint effusions were present, all more conspicuously delineated from surrounding inflammatory change on the fat-saturated T1WI with gadolinium. The average imaging time for the fat-saturated T1WI with gadolinium was 6.75 min, while that of the T2-weighted sequences was 5.75 min. Conclusion. Routine use of gadolinium is not warranted. Instead, gadolinium should be reserved for clinically suspected infection in or around a joint, and in cases refractory to medical or surgical treatment due to possible abscess formation. (orig.)

  3. MR imaging pulse sequence rationale: SD-, T1-, and T2-weighted images

    International Nuclear Information System (INIS)

    Sax, S.; Weathers, S.W.; Schneiders, N.J.; Horowitz, B.L.; Mawad, M.E.; Sandlin, M.E.; Blackwell, R.; Bryan, R.N.

    1986-01-01

    Over 500 patients have been examined with a pulse sequence designed to provide spin-density (SD)-weighted images (TR=3 sec, TE=35 msec), T1-weighted images (TR=0.3 sec, TE=35msec), and T2-weighted images (TR=3 sec, TE=105 msec) from which calculated ''synthesized'' images and SD, T1, and T2 calculated images could be obtained. Each image contributes unique information. SD-weighted images optimally display anatomy and often best highlight pathology. T1-weighted images are critical in assessing cerebral hemorrhages. T2-weighted images best display most lesions, but yield incomplete information in 35% of cases. All three types of ''weighted'' images are necessary to optimally display anatomy and fully characterize a lesion. Computerized calculations and simulations suggest that no other combination of pulse sequences yields equal information for a given examination time

  4. Basic evaluation of the new pulse sequence for simultaneous acquisition of T1- and T2-weighted images

    International Nuclear Information System (INIS)

    Kurose, Atsunari; Takahashi, Tohru; Ohishi, Tae; Ishikawa, Akihiro

    2006-01-01

    A novel pulse sequence that enables simultaneous acquisition of T1-weighted (T1W) and T2-weighted (T2W) images is presented. In this new technique, the inversion recovery (IR) pulse of conventional fast inversion recovery (Fast IR) is replaced with a pulse train that consists of a fast spin echo (FSE) and 180(y)+90(x) for driven inversion (DI). By using a shorter T1 and independent k-space ordering, the first part of the sequence provides T2W images and the second part provides T1W images, thereby enabling simultaneous acquisition in a single scan time comparable to that of Fast IR. Signal simulation also was conducted, and this was compared with conventional scanning techniques using normal volunteers. In the human studies, both T1W and T2W images showed the same image quality as conventional images, suggesting the potential for this technique to replace the combination of Fast IR and T2W FSE for scan-time reduction. (author)

  5. DESTINY, The Dark Energy Space Telescope

    Science.gov (United States)

    Pasquale, Bert A.; Woodruff, Robert A.; Benford, Dominic J.; Lauer, Tod

    2007-01-01

    We have proposed the development of a low-cost space telescope, Destiny, as a concept for the NASA/DOE Joint Dark Energy Mission. Destiny is a 1.65m space telescope, featuring a near-infrared (0.85-1.7m) survey camera/spectrometer with a moderate flat-field field of view (FOV). Destiny will probe the properties of dark energy by obtaining a Hubble diagram based on Type Ia supernovae and a large-scale mass power spectrum derived from weak lensing distortions of field galaxies as a function of redshift.

  6. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  7. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  8. Dark chocolate and blood pressure: a novel study from Jordan.

    Science.gov (United States)

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  9. Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chandarana, Hersh; Block, Kai T.; Winfeld, Matthew J.; Lala, Shailee V.; Mazori, Daniel; Giuffrida, Emalyn; Babb, James S.; Milla, Sarah S. [New York University Langone Medical Center, Department of Radiology, New York, NY (United States)

    2014-02-15

    To compare the image quality of contrast-enhanced abdominopelvic 3D fat-suppressed T1-weighted gradient-echo imaging with radial and conventional Cartesian k-space acquisition schemes in paediatric patients. Seventy-three consecutive paediatric patients were imaged at 1.5 T with sequential contrast-enhanced T1-weighted Cartesian (VIBE) and radial gradient echo (GRE) acquisition schemes with matching parameters when possible. Cartesian VIBE was acquired as a breath-hold or as free breathing in patients who could not suspend respiration, followed by free-breathing radial GRE in all patients. Two paediatric radiologists blinded to the acquisition schemes evaluated multiple parameters of image quality on a five-point scale, with higher score indicating a more optimal examination. Lesion presence or absence, conspicuity and edge sharpness were also evaluated. Mixed-model analysis of variance was performed to compare radial GRE and Cartesian VIBE. Radial GRE had significantly (all P < 0.001) higher scores for overall image quality, hepatic edge sharpness, hepatic vessel clarity and respiratory motion robustness than Cartesian VIBE. More lesions were detected on radial GRE by both readers than on Cartesian VIBE, with significantly higher scores for lesion conspicuity and edge sharpness (all P < 0.001). Radial GRE has better image quality and lesion conspicuity than conventional Cartesian VIBE in paediatric patients undergoing contrast-enhanced abdominopelvic MRI. (orig.)

  10. Optimal MR pulse sequences for hepatic hemangiomas : comparison of T2-weighted turbo-spin-echo, T2-weighted breath-hold turbo-spin-echo, and T1-weighted FLASH dynamic imaging

    International Nuclear Information System (INIS)

    Wang, Wen Chao; Choi, Byung Ihn; Han, Joon Koo; Kim, Tae Kyoung; Cho, Soon Gu

    1997-01-01

    To optimize MR imaging pulse sequences in the imaging of hepatic hemangioma and to evaluate on dynamic MR imaging the enhancing characteristics of the lesions. Twenty patients with 35 hemangiomas were studied by using Turbo-spin-echo (TSE) sequence (T2-weighted, T2- and heavily T2-weighted breath-hold) and T1-weighted FLASH imaging acquired before, immediately on, and 1, 3 and 5 minutes after injection of a bolus of Gd-DTPA (0.1mmol/kg). Phased-array multicoil was employed. Images were quantitatively analyzed for lesion-to-liver signal difference to noise ratios (SD/Ns), and lesion-to-liver signal ratios (H/Ls), and qualitatively analyzed for lesion conspicuity. The enhancing characteristics of the hemangiomas were described by measuring the change of signal intensity as a curve in T1-weighted FLASH dynamic imaging. For T2-weighted images, breath-hold T2-weighted TSE had a slightly higher SD/N than other pulse sequences, but there was no statistical difference in three fast pulse sequences (p=0.211). For lesion conspicuity, heavily T2-weighted breath-hold TSE images was superior to T2-weighted breath-hold or non-breath-hold TSE (H/L, 5.75, 3.81, 2.87, respectively, p<0.05). T2-weighted breath-hold TSE imaging was more effective than T2-weighted TSE imaging in removing lesion blurring or lack of sharpness, and there was a 12-fold decrease in acquisition time (20sec versus 245 sec). T1-weighted FLASH dynamic images of normal liver showed peak enhancement at less than 1 minute, and of hemangioma at more than 3 minutes;the degree of enhancement for hemangioma decreased after a 3 minute delay. T2-weighed breath-hold TSE imaging and Gd-DTPA enhanced FLASH dynamic imaging with 5 minutes delay are sufficient for imaging hepatic hemangiomas

  11. Effectiveness of a Rapid Lumbar Spine MRI Protocol Using 3D T2-Weighted SPACE Imaging Versus a Standard Protocol for Evaluation of Degenerative Changes of the Lumbar Spine.

    Science.gov (United States)

    Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank

    2016-09-01

    Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of

  12. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    International Nuclear Information System (INIS)

    Erdem, L. Oktay; Erdem, C. Zuhal; Acikgoz, Bektas; Gundogdu, Sadi

    2005-01-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times

  13. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  14. Gadoxate-enhanced T1-weighted MR cholangiography: comparison of 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, C.; Schima, W.; Weber, M.; Mang, T.; Nemec, S.; Kulinna-Cosentini, C.; Bastati, N.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2009-06-15

    Purpose: to qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5 T and 3.0 T. Materials and methods: a total of 40 patients with a non-dilated biliary system were retrospectively included in the study. T1-weighted MR cholangiography 20 min after IV administration of 0.025 mmol/kg gadoxate (Primovist trademark) was performed in 20 patients at 1.5 T and in another 20 patients at 3.0 T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct - LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: the CNRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0 T. Qualitative analysis showed a significant superiority for 3.0 T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). (orig.)

  15. Assessment of Silent T1-weighted head imaging at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Costagli, Mauro; Tiberi, Gianluigi; Tosetti, Michela [Imago7 Foundation, Pisa (Italy); IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Symms, Mark R. [GE Applied Science Laboratory, Pisa (Italy); Angeli, Lorenzo [University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Kelley, Douglas A.C. [GE Healthcare Technologies, San Francisco, CA (United States); Biagi, Laura [IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Farnetani, Andrea [University of Ferrara, Engineering Department, Ferrara (Italy); Materiacustica s.r.l., Ferrara (Italy); Rua, Catarina [University of Pisa, Department of Physics, Pisa (Italy); Donatelli, Graziella [Azienda Ospedaliero-Universitaria Pisana (AOUP), Neuroradiology Unit, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Cosottini, Mirco [Imago7 Foundation, Pisa (Italy); University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy)

    2016-06-15

    This study aimed to assess the performance of a ''Silent'' zero time of echo (ZTE) sequence for T1-weighted brain imaging using a 7 T MRI system. The Silent sequence was evaluated qualitatively by two neuroradiologists, as well as quantitatively in terms of tissue contrast, homogeneity, signal-to-noise ratio (SNR) and acoustic noise. It was compared to conventional T1-weighted imaging (FSPGR). Adequacy for automated segmentation was evaluated in comparison with FSPGR acquired at 7 T and 1.5 T. Specific absorption rate (SAR) was also measured. Tissue contrast and homogeneity in Silent were remarkable in deep brain structures and in the occipital and temporal lobes. Mean tissue contrast was significantly (p < 0.002) higher in Silent (0.25) than in FSPGR (0.11), which favoured automated tissue segmentation. On the other hand, Silent images had lower SNR with respect to conventional imaging: average SNR of FSPGR was 2.66 times that of Silent. Silent images were affected by artefacts related to projection reconstruction, which nevertheless did not compromise the depiction of brain tissues. Silent acquisition was 35 dB(A) quieter than FSPGR and less than 2.5 dB(A) louder than ambient noise. Six-minute average SAR was <2 W/kg. The ZTE Silent sequence provides high-contrast T1-weighted imaging with low acoustic noise at 7 T. (orig.)

  16. Difference between T1 and T2 weighted MR images in avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo

    1990-01-01

    T 1 and T 2 weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T 2 weighted images than in T 1 weighted images. The area of low intensity on T 1 weighted image and high on T 2 weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T 1 and T 2 weighted images must be taken into consideration especially in determination of the border of affected bone. (author)

  17. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  18. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  19. First Dark Matter Search Results from the XENON1T Experiment

    Science.gov (United States)

    Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; di Gangi, P.; di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Gardner, R.; Geis, C.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Mariş, I.; Marrodán Undagoitia, T.; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morâ, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M.-C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Riedel, B.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Saldanha, R.; Dos Santos, J. M. F.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Scotto Lavina, L.; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. V.; Stein, A.; Thapa, S.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Upole, N.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.; Xenon Collaboration

    2017-11-01

    We report the first dark matter search results from XENON1T, a ˜2000 -kg -target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042 ±12 )-kg fiducial mass and in the [5 ,40 ] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93 ±0.25 )×10-4 events /(kg ×day ×keVee) , the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV /c2 , with a minimum of 7.7 ×10-47 cm2 for 35 -GeV /c2 WIMPs at 90% C.L.

  20. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  1. Results from the 1 tonne*year Dark Matter Search with XENON1T

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    Weakly Interacting Massive Particles (WIMPs) are an excellent candidate for the mysterious Dark Matter in the Universe. The XENON1T experiment at LNGS is the world’s largest and most sensitive experiment for the direct detection of WIMPs via nuclear recoils. Details of the experiment and of the achieved unprecedented low background conditions will be covered and new results from a record exposure of 1 tonne x year will be presented for the first time.

  2. Inversion recovery RARE: Clinical application of T2-weighted CSF-suppressed rapid sequence

    International Nuclear Information System (INIS)

    Goetz, G.F.; Hennig, J.; Ziyeh, S.

    1995-01-01

    Inversion-Recovery RARE is a strongly T 2 -weighted fast sequence in which the CSF appears dark. This sequence was used in more than 100 patients. Retrospective analysis of 80 patients with cerebrovascular and inflammatory disease was carried out. The IR-RARE sequence proved to be particularly suitable for identifying small lesions in the neighbourhood of the subarachnoid space. We illustrate the typical contrast provided by this sequence, and describe its characteristics, exemplifying the advantages it offers for the diagnosis of multiple sclerosis, cerebral microangiopathy and brain infarction. (orig.) [de

  3. Assessment of T2- and T1-weighted MRI brain lesion load in patients with subcortical vascular encephalopathy

    International Nuclear Information System (INIS)

    Gass, A.; Oster, M.; Cohen, S.; Daffertshofer, M.; Schwartz, A.; Hennerici, M.G.

    1998-01-01

    Previous cross-sectional studies in patients with subcortical vascular encephalopathy (SVE) have shown little or no correlation between brain lesion load and clinical disability, which could be due to the low specificity of T2-weighted MRI. Recent studies have indicated that T1-weighted MRI may be more specific than T2-weighted MRI for severe tissue destruction. We studied 37 patients with a diagnosis of SVE and 11 normal controls with standardised T1- and T2-weighted MRI. All patients underwent detailed clinical assessment including a neuropsychological test battery and computerised gait analysis. Both the T2- and T1-weighted total MRI lesion loads different between patients and controls different, particularly T1. The ratio of T2-/T1-weighted lesion load was lower in controls than in patients. There was no overall correlation of T1- or T2-weighted lesion load with clinical disability, but group comparison of patients with severe and mild clinical deficits showed different lesion loads. We suggest that T1- and T2-weighted MRI lesion loads demonstrate relevant structural abnormality in patients with SVE. (orig.)

  4. Top-flavoured dark matter in Dark Minimal Flavour Violation

    Energy Technology Data Exchange (ETDEWEB)

    Blanke, Monika; Kast, Simon [Institut für Kernphysik, Karlsruhe Institute of Technology,Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Institut für Theoretische Teilchenphysik, Karlsruhe Institute of Technology,Engesserstraße 7, D-76128 Karlsruhe (Germany)

    2017-05-31

    We study a simplified model of top-flavoured dark matter in the framework of Dark Minimal Flavour Violation. In this setup the coupling of the dark matter flavour triplet to right-handed up-type quarks constitutes the only new source of flavour and CP violation. The parameter space of the model is restricted by LHC searches with missing energy final states, by neutral D meson mixing data, by the observed dark matter relic abundance, and by the absence of signal in direct detection experiments. We consider all of these constraints in turn, studying their implications for the allowed parameter space. Imposing the mass limits and coupling benchmarks from collider searches, we then conduct a combined analysis of all the other constraints, revealing their non-trivial interplay. Especially interesting is the combination of direct detection and relic abundance constraints, having a severe impact on the structure of the dark matter coupling matrix. We point out that future bounds from upcoming direct detection experiments, such as XENON1T, XENONnT, LUX-ZEPLIN, and DARWIN, will exclude a large part of the parameter space and push the DM mass to higher values.

  5. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  6. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  7. Plane Symmetric Dark Energy Models in the Form of Wet Dark Fluid in f ( R, T) Gravity

    Science.gov (United States)

    Chirde, V. R.; Shekh, S. H.

    2016-06-01

    In this paper, we have investigated the plane symmetric space-time with wet dark fluid (WDF), which is a candidate for dark energy, in the framework of f ( R, T) gravity Harko et al. 2011, Phys. Rev. D, 84, 024020), where R and T denote the Ricci scalar and the trace of the energy-momentum tensor respectively. We have used the equation of state in the form of WDF for the dark energy component of the Universe. It is modeled on the equation of state p = ω( ρ - ρ ∗). The exact solutions to the corresponding field equations are obtained for power-law and exponential volumetric expansion. The geometrical and physical parameters for both the models are studied. Also, we have discussed the well-known astrophysical phenomena, namely the look-back time, proper distance, the luminosity distance and angular diameter distance with red shift.

  8. Scalar Dark Matter From Theory Space

    Energy Technology Data Exchange (ETDEWEB)

    Birkedal-Hansen, Andreas; Wacker, Jay G.

    2003-12-26

    The scalar dark matter candidate in a prototypical theory space little Higgs model is investigated. We review all details of the model pertinent to a relic density calculation. We perform a thermal relic density calculation including couplings to the gauge and Higgs sectors of the model. We find two regions of parameter space that give acceptable dark matter abundances. The first region has a dark matter candidate with a mass {Omicron}(100 GeV), the second region has a candidate with a mass greater than {Omicron}(500 GeV). The dark matter candidate in either region is an admixture of an SU(2) triplet and an SU(2) singlet, thereby constituting a possible WIMP (weakly interacting massive particle).

  9. Scalar dark matter from theory space

    International Nuclear Information System (INIS)

    Birkedal-Hansen, Andreas; Wacker, Jay G.

    2004-01-01

    The scalar dark matter candidate in a prototypical theory space little Higgs model is investigated. We review all details of the model pertinent to a relic density calculation. We perform a thermal relic density calculation including couplings to the gauge and Higgs sectors of the model. We find two regions of parameter space that give acceptable dark matter abundances. The first region has a dark matter candidate with a mass O(100 GeV), the second region has a candidate with a mass greater than O(500 GeV). The dark matter candidate in either region is an admixture of an SU(2) triplet and an SU(2) singlet, thereby constituting a possible weakly interacting massive particle

  10. Approximation of Müntz-Szász type in weighted spaces

    Energy Technology Data Exchange (ETDEWEB)

    Sedletskii, A M [M. V. Lomonosov Moscow State University, Faculty of Mechanics and Mathematics, Moscow (Russian Federation)

    2013-07-31

    The paper looks at whether a system of exponentials exp(-λ{sub n}t), Reλ{sub n}>0, is complete in various function spaces on the half-line R{sub +}. Wide classes of Banach spaces E and F of functions on R{sub +} are described such that this system is complete in E and F simultaneously. A test is established to determine when this system is complete in the weighted spaces C{sub 0} and L{sup p} with weight (1+t){sup α} on R{sub +}, for α<0 and α<-1, respectively. Bibliography: 18 titles.

  11. First Dark Matter Search Results from the XENON1T Experiment.

    Science.gov (United States)

    Aprile, E; Aalbers, J; Agostini, F; Alfonsi, M; Amaro, F D; Anthony, M; Arneodo, F; Barrow, P; Baudis, L; Bauermeister, B; Benabderrahmane, M L; Berger, T; Breur, P A; Brown, A; Brown, A; Brown, E; Bruenner, S; Bruno, G; Budnik, R; Bütikofer, L; Calvén, J; Cardoso, J M R; Cervantes, M; Cichon, D; Coderre, D; Colijn, A P; Conrad, J; Cussonneau, J P; Decowski, M P; de Perio, P; Di Gangi, P; Di Giovanni, A; Diglio, S; Eurin, G; Fei, J; Ferella, A D; Fieguth, A; Fulgione, W; Gallo Rosso, A; Galloway, M; Gao, F; Garbini, M; Gardner, R; Geis, C; Goetzke, L W; Grandi, L; Greene, Z; Grignon, C; Hasterok, C; Hogenbirk, E; Howlett, J; Itay, R; Kaminsky, B; Kazama, S; Kessler, G; Kish, A; Landsman, H; Lang, R F; Lellouch, D; Levinson, L; Lin, Q; Lindemann, S; Lindner, M; Lombardi, F; Lopes, J A M; Manfredini, A; Mariş, I; Marrodán Undagoitia, T; Masbou, J; Massoli, F V; Masson, D; Mayani, D; Messina, M; Micheneau, K; Molinario, A; Morå, K; Murra, M; Naganoma, J; Ni, K; Oberlack, U; Pakarha, P; Pelssers, B; Persiani, R; Piastra, F; Pienaar, J; Pizzella, V; Piro, M-C; Plante, G; Priel, N; Rauch, L; Reichard, S; Reuter, C; Riedel, B; Rizzo, A; Rosendahl, S; Rupp, N; Saldanha, R; Dos Santos, J M F; Sartorelli, G; Scheibelhut, M; Schindler, S; Schreiner, J; Schumann, M; Scotto Lavina, L; Selvi, M; Shagin, P; Shockley, E; Silva, M; Simgen, H; Sivers, M V; Stein, A; Thapa, S; Thers, D; Tiseni, A; Trinchero, G; Tunnell, C; Vargas, M; Upole, N; Wang, H; Wang, Z; Wei, Y; Weinheimer, C; Wulf, J; Ye, J; Zhang, Y; Zhu, T

    2017-11-03

    We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40]  keV_{nr} energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10^{-4}  events/(kg×day×keV_{ee}), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10  GeV/c^{2}, with a minimum of 7.7×10^{-47}  cm^{2} for 35-GeV/c^{2} WIMPs at 90% C.L.

  12. The Multivariate Müntz-Szasz Problem in Weighted Banach Space on Rn

    Directory of Open Access Journals (Sweden)

    Xiangdong Yang

    2014-01-01

    Full Text Available The purpose of this paper is to give an extension of Müntz-Szasz theorems to multivariable weighted Banach space. Denote by {λk=(λk1,λk2,...,λkn}k=1∞ a sequence of real numbers in R+n. The completeness of monomials {tλk} in Cα is investigated, where Cα is the weighted Banach spaces which consist of complex continuous functions f defined on Rn with f(t exp(-α(t vanishing at infinity in the uniform norm.

  13. Fast T1-weighted imaging using GRASE sequence for the female pelvis

    International Nuclear Information System (INIS)

    Dohke, Masako; Watanabe, Yuji; Kumashiro, Masayuki; Amoh, Yoshiki; Ishimori, Takayoshi; Oda, Kazushige; Okumura, Akira; Koike, Shinji; Dodo, Yoshihiro

    1998-01-01

    GRASE sequence, a combination of TSE and gradient echo, has been developed as a fast T 2 -weighted imaging technique. We have modified the GRASE sequence to be used for fast T 1 -weighted imaging of the female pelvis. In this article, we compared image quality and incidence of artifacts between T 1 -weighted GRASE images and conventional T 1 -weighted SE images. In a phantom study, signal-to-noise ratio was inferior in the GRASE images relative to corresponding on SE images. Susceptibility and chemical shift artifacts seen in GRASE images were seen with almost equal incidence in SE and TSE images. In a clinical study, we compared GRASE images with SE images in six patients with endometrial cysts and four patients with dermoid cysts. The overall image quality obtained with GRASE sequence was satisfactory in all patients and was almost identical with that obtained with SE sequence. GRASE images demonstrated endometrial cysts and dermoid cysts as clearly as did SE images. T 1 -weighted GRASE imaging, however, has a relatively long TE (35 ms) for T 1 -weighted images, which makes the signal intensity of urine and uterine endometrium with long T 2 values higher than in SE images. In conclusion, GRASE sequence can be used for fast T 1 -weighted imaging of the female pelvis because of short imaging time. (author)

  14. Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T

    International Nuclear Information System (INIS)

    Wolff, Andrew B.; Pesce, Lorenzo L.; Wu, Jim S.; Smart, L.R.; Medvecky, Michael J.; Haims, Andrew H.

    2009-01-01

    At our institution, fast spin-echo (FSE) proton density (PD) imaging is used to evaluate articular cartilage, while conventional spin-echo (CSE) T1-weighted sequences have been traditionally used to characterize meniscal pathology. We sought to determine if FSE PD-weighted sequences are equivalent to CSE T1-weighted sequences in the detection of meniscal tears, obviating the need to perform both sequences. We retrospectively reviewed the records of knee arthroscopies performed by two arthroscopy-focused surgeons from an academic medical center over a 2-year period. The preoperative MRI images were interpreted independently by two fellowship-trained musculoskeletal radiologists who graded the sagittal CSE T1 and FSE PD sequences at different sittings with grades 1-5, where 1 = normal meniscus, 2 = probable normal meniscus, 3 indeterminate, 4 = probable torn meniscus, and 5 = torn meniscus. Each meniscus was divided into an anterior and posterior half, and these halves were graded separately. Operative findings provided the gold standard. Receiver operating characteristic (ROC) analysis was performed to compare the two sequences. There were 131 tears in 504 meniscal halves. Using ROC analysis, the reader 1 area under curve for FSE PD was significantly better than CSE T1 (0.939 vs. 0.902, >95% confidence). For reader 2, the difference met good criteria for statistical non-inferiority but not superiority (0.913 for FSE PD and 0.908 for CSE T1; >95% non-inferiority for difference at most of -0.027). FSE PD-weighted sequences, using our institutional protocol, are not inferior to CSE T1-weighted sequences for the detection of meniscal tears and may be superior. (orig.)

  15. Material radioassay and selection for the XENON1T dark matter experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, E.; Anthony, M.; De Perio, P.; Gao, F.; Goetzke, L.W.; Greene, Z.; Lin, Q.; Messina, M.; Plante, G.; Rizzo, A.; Zhang, Y. [Columbia University, Physics Department, New York, NY (United States); Aalbers, J.; Breur, P.A.; Brown, A.; Colijn, A.P.; Decowski, M.P.; Hogenbirk, E.; Tiseni, A. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Agostini, F. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); University of Bologna, Department of Physics and Astrophysics, Bologna (Italy); INFN-Bologna (Italy); Alfonsi, M.; Geis, C.; Grignon, C.; Oberlack, U.; Scheibelhut, M.; Schindler, S. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Amaro, F.D.; Cardoso, J.M.R.; Lopes, J.A.M.; Santos, J.M.F. dos; Silva, M. [University of Coimbra, LIBPhys, Department of Physics, Coimbra (Portugal); Arneodo, F.; Benabderrahmane, M.L.; Maris, I. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Barrow, P.; Baudis, L.; Di Giovanni, A.; Franco, D.; Galloway, M.; Kessler, G.; Kish, A.; Mayani, D.; Pakarha, P.; Piastra, F.; Wei, Y.; Wulf, J. [University of Zurich, Physik Institut, Zurich (Switzerland); Bauermeister, B. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Stockholm University, AlbaNova, Oskar Klein Centre, Department of Physics, Stockholm (Sweden); Berger, T.; Brown, E.; Piro, M.C. [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy, Troy, NY (United States); Sivers, M. von [Rensselaer Polytechnic Institute, Troy, NY (United States). Dept. of Physics, Applied Physics and Astronomy; Bern Univ. (Switzerland). Albert Einstein Center for Fundamental Physics; Bruenner, S.; Cichon, D.; Eurin, G.; Hasterok, C.; Lindemann, S.; Lindner, M.; Marrodan Undagoitia, T.; Pizzella, V.; Rauch, L.; Rupp, N.; Schreiner, J.; Simgen, H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Bruno, G.; Gallo Rosso, A.; Molinario, A.; Laubenstein, M.; Nisi, S. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Budnik, R.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Manfredini, A.; Priel, N. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); Buetikofer, L.; Coderre, D.; Kaminsky, B.; Schumann, M. [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Calven, J.; Conrad, J.; Ferella, A.D.; Pelssers, B. [Stockholm University, AlbaNova, Oskar Klein Centre, Department of Physics, Stockholm (Sweden); Cervantes, M.; Lang, R.F.; Masson, D.; Pienaar, J.; Reichard, S.; Reuter, C. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Cussonneau, J.P.; Diglio, S.; Le Calloch, M.; Masbou, J.; Micheneau, K.; Persiani, R.; Thers, D. [Universite de Nantes, SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Nantes (France); Di Gangi, P.; Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M. [University of Bologna, Department of Physics and Astrophysics, Bologna (Italy); INFN-Bologna (Italy); Fei, J.; Ni, K.; Ye, J. [University of California, Department of Physics, San Diego, CA (United States); Fieguth, A.; Murra, M.; Rosendahl, S.; Weinheimer, C. [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Fulgione, W. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Gran Sasso Science Institute, L' Aquila (Italy); INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Torino (Italy); Grandi, L.; Saldanha, R.; Shockley, E.; Upole, N. [University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Miguez, B.; Trinchero, G. [INFN-Torino (Italy); Osservatorio Astrofisico di Torino, Torino (Italy); Naganoma, J.; Shagin, P. [Rice University, Department of Physics and Astronomy, Houston, TX (United States); Scotto Lavina, L. [Universite Pierre et Marie Curie, Universite Paris Diderot, CNRS/IN2P3, LPNHE, Paris (France); Stein, A.; Wang, H. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Tunnell, C. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); University of Chicago, Department of Physics and Kavli Institute of Cosmological Physics, Chicago, IL (United States); Collaboration: XENON Collaboration

    2017-12-15

    The XENON1T dark matter experiment aims to detect weakly interacting massive particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations. (orig.)

  16. Black Hole Space-time In Dark Matter Halo

    OpenAIRE

    Xu, Zhaoyi; Hou, Xian; Gong, Xiaobo; Wang, Jiancheng

    2018-01-01

    For the first time, we obtain the analytical form of black hole space-time metric in dark matter halo for the stationary situation. Using the relation between the rotation velocity (in the equatorial plane) and the spherical symmetric space-time metric coefficient, we obtain the space-time metric for pure dark matter. By considering the dark matter halo in spherical symmetric space-time as part of the energy-momentum tensors in the Einstein field equation, we then obtain the spherical symmetr...

  17. Difference between T sub 1 and T sub 2 weighted MR images in avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo [Tokyo Univ. (Japan). Faculty of Medicine

    1990-01-01

    T{sub 1} and T{sub 2} weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T{sub 2} weighted images than in T{sub 1} weighted images. The area of low intensity on T{sub 1} weighted image and high on T{sub 2} weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T{sub 1} and T{sub 2} weighted images must be taken into consideration especially in determination of the border of affected bone. (author).

  18. High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3 T vs. 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Arizono, Shigeki [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: arizono@kuhp.kyoto-u.ac.jp; Isoda, Hiroyoshi [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: sayuki@kuhp.kyoto-u.ac.jp; Maetani, Yoji S. [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: mbo@kuhp.kyoto-u.ac.jp; Hirokawa, Yuusuke [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: yuusuke@kuhp.kyoto-u.ac.jp; Shimada, Kotaro [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: kotaro@kuhp.kyoto-u.ac.jp; Nakamoto, Yuji [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ynakamo1@kuhp.kyoto-u.ac.jp; Shibata, Toshiya [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ksj@kuhp.kyoto-u.ac.jp; Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ktogashi@kuhp.kyoto-u.ac.jp

    2010-01-15

    Purpose: The aim of this study was to evaluate image quality of 3D MR cholangiography (MRC) using high sampling efficiency technique (SPACE) at 3 T compared with 1.5 T. Methods and materials: An IRB approved prospective study was performed with 17 healthy volunteers using both 3 and 1.5 T MR scanners. MRC images were obtained with free-breathing navigator-triggered 3D T2-weighted turbo spin-echo sequence with SPACE (TR, >2700 ms; TE, 780 ms at 3 T and 801 ms at 1.5 T; echo-train length, 121; voxel size, 1.1 mm x 1.0 mm x 0.84 mm). The common bile duct (CBD) to liver contrast-to-noise ratios (CNRs) were compared between 3 and 1.5 T. A five-point scale was used to compare overall image quality and visualization of the third branches of bile duct (B2, B6, and B8). The depiction of cystic duct insertion and the highest order of bile duct visible were also compared. The results were compared using the Wilcoxon signed-ranks test. Results: CNR between the CBD and liver was significantly higher at 3 T than 1.5 T (p = 0.0006). MRC at 3 T showed a significantly higher overall image quality (p = 0.0215) and clearer visualization of B2 (p = 0.0183) and B6 (p = 0.0106) than at 1.5 T. In all analyses of duct visibility, 3 T showed higher scores than 1.5 T. Conclusion: 3 T MRC using SPACE offered better image quality than 1.5 T. SPACE technique facilitated high-resolution 3D MRC with excellent image quality at 3 T.

  19. Role of T1 mapping as a complementary tool to T2* for non-invasive cardiac iron overload assessment.

    Science.gov (United States)

    Torlasco, Camilla; Cassinerio, Elena; Roghi, Alberto; Faini, Andrea; Capecchi, Marco; Abdel-Gadir, Amna; Giannattasio, Cristina; Parati, Gianfranco; Moon, James C; Cappellini, Maria D; Pedrotti, Patrizia

    2018-01-01

    Iron overload-related heart failure is the principal cause of death in transfusion dependent patients, including those with Thalassemia Major. Linking cardiac siderosis measured by T2* to therapy improves outcomes. T1 mapping can also measure iron; preliminary data suggests it may have higher sensitivity for iron, particularly for early overload (the conventional cut-point for no iron by T2* is 20ms, but this is believed insensitive). We compared T1 mapping to T2* in cardiac iron overload. In a prospectively large single centre study of 138 Thalassemia Major patients and 32 healthy controls, we compared T1 mapping to dark blood and bright blood T2* acquired at 1.5T. Linear regression analysis was used to assess the association of T2* and T1. A "moving window" approach was taken to understand the strength of the association at different levels of iron overload. The relationship between T2* (here dark blood) and T1 is described by a log-log linear regression, which can be split in three different slopes: 1) T2* low, 30ms, weak relationship. All subjects with T2*20ms, 38% had low T1 with most of the subjects in the T2* range 20-30ms having a low T1. In established cardiac iron overload, T1 and T2* are concordant. However, in the 20-30ms T2* range, T1 mapping appears to detect iron. These data support previous suggestions that T1 detects missed iron in 1 out of 3 subjects with normal T2*, and that T1 mapping is complementary to T2*. The clinical significance of a low T1 with normal T2* should be further investigated.

  20. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  1. Effects of Restricted Fructose Access on Body Weight and Blood Pressure Circadian Rhythms

    Directory of Open Access Journals (Sweden)

    Danielle Senador

    2012-01-01

    Full Text Available High-fructose diet is known to produce cardiovascular and metabolic pathologies. The objective was to determine whether the timing of high fructose (10% liquid solution intake affect the metabolic and cardiovascular outcomes. Male C57BL mice with radiotelemetric probes were divided into four groups: (1 24 h water (control; (2 24 h fructose (F24; (3 12 h fructose during the light phase (F12L; (4 12 h fructose during the dark phase (F12D. All fructose groups had higher fluid intake. Body weight was increased in mice on restricted access with no difference in total caloric intake. Fasting glycemia was higher in groups with restricted access. F24 mice showed a fructose-induced blood pressure increase during the dark period. Blood pressure circadian rhythms were absent in F12L mice. Results suggest that the timing of fructose intake is an important variable in the etiology of cardiovascular and metabolic pathologies produced by high fructose consumption.

  2. Trigonometric bases for matrix weighted Lp-spaces

    DEFF Research Database (Denmark)

    Nielsen, Morten

    2010-01-01

    We give a complete characterization of 2π-periodic matrix weights W for which the vector-valued trigonometric system forms a Schauder basis for the matrix weighted space Lp(T;W). Then trigonometric quasi-greedy bases for Lp(T;W) are considered. Quasi-greedy bases are systems for which the simple...

  3. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE).

    Science.gov (United States)

    Zhu, Chengcheng; Tian, Bing; Chen, Luguang; Eisenmenger, Laura; Raithel, Esther; Forman, Christoph; Ahn, Sinyeob; Laub, Gerhard; Liu, Qi; Lu, Jianping; Liu, Jing; Hess, Christopher; Saloner, David

    2018-06-01

    Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. A 3D accelerated T 1 -weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T 1 -weighted SPACE while maintaining good image quality.

  4. Hierarchical phase space structure of dark matter haloes: Tidal debris, caustics, and dark matter annihilation

    International Nuclear Information System (INIS)

    Afshordi, Niayesh; Mohayaee, Roya; Bertschinger, Edmund

    2009-01-01

    Most of the mass content of dark matter haloes is expected to be in the form of tidal debris. The density of debris is not constant, but rather can grow due to formation of caustics at the apocenters and pericenters of the orbit, or decay as a result of phase mixing. In the phase space, the debris assemble in a hierarchy that is truncated by the primordial temperature of dark matter. Understanding this phase structure can be of significant importance for the interpretation of many astrophysical observations and, in particular, dark matter detection experiments. With this purpose in mind, we develop a general theoretical framework to describe the hierarchical structure of the phase space of cold dark matter haloes. We do not make any assumption of spherical symmetry and/or smooth and continuous accretion. Instead, working with correlation functions in the action-angle space, we can fully account for the hierarchical structure (predicting a two-point correlation function ∝ΔJ -1.6 in the action space), as well as the primordial discreteness of the phase space. As an application, we estimate the boost to the dark matter annihilation signal due to the structure of the phase space within virial radius: the boost due to the hierarchical tidal debris is of order unity, whereas the primordial discreteness of the phase structure can boost the total annihilation signal by up to an order of magnitude. The latter is dominated by the regions beyond 20% of the virial radius, and is largest for the recently formed haloes with the least degree of phase mixing. Nevertheless, as we argue in a companion paper, the boost due to small gravitationally-bound substructure can dominate this effect at low redshifts.

  5. Hierarchical phase space structure of dark matter haloes: Tidal debris, caustics, and dark matter annihilation

    Science.gov (United States)

    Afshordi, Niayesh; Mohayaee, Roya; Bertschinger, Edmund

    2009-04-01

    Most of the mass content of dark matter haloes is expected to be in the form of tidal debris. The density of debris is not constant, but rather can grow due to formation of caustics at the apocenters and pericenters of the orbit, or decay as a result of phase mixing. In the phase space, the debris assemble in a hierarchy that is truncated by the primordial temperature of dark matter. Understanding this phase structure can be of significant importance for the interpretation of many astrophysical observations and, in particular, dark matter detection experiments. With this purpose in mind, we develop a general theoretical framework to describe the hierarchical structure of the phase space of cold dark matter haloes. We do not make any assumption of spherical symmetry and/or smooth and continuous accretion. Instead, working with correlation functions in the action-angle space, we can fully account for the hierarchical structure (predicting a two-point correlation function ∝ΔJ-1.6 in the action space), as well as the primordial discreteness of the phase space. As an application, we estimate the boost to the dark matter annihilation signal due to the structure of the phase space within virial radius: the boost due to the hierarchical tidal debris is of order unity, whereas the primordial discreteness of the phase structure can boost the total annihilation signal by up to an order of magnitude. The latter is dominated by the regions beyond 20% of the virial radius, and is largest for the recently formed haloes with the least degree of phase mixing. Nevertheless, as we argue in a companion paper, the boost due to small gravitationally-bound substructure can dominate this effect at low redshifts.

  6. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, E.; Contreras, H.; Goetzke, L.W.; Fernandez, A.J.M.; Messina, M.; Plante, G.; Rizzo, A. [Columbia University, Physics Department, New York, NY (United States); Agostini, F. [INFN-Laboratori Nazionali del Gran Sasso (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Bologna Univ., Department of Physics and Astrophysics, Bologna (Italy); INFN, Bologna (Italy); Alfonsi, M. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Arazi, L.; Budnik, R.; Duchovni, E.; Gross, E.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Priel, N.; Vitells, O. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); Arisaka, K.; Lyashenko, A.; Meng, Y.; Pantic, E.; Teymourian, A.; Wang, H. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Arneodo, F.; Di Giovanni, A. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Auger, M.; Barrow, P.; Baudis, L.; Behrens, A.; Galloway, M.; Kessler, G.; Kish, A.; Mayani, D.; Pakarha, P.; Piastra, F. [University of Zurich, Physik-Institut, Zurich (Switzerland); Balan, C.; Cardoso, J.M.R.; Lopes, J.A.M.; Santos, J.M.F. dos [University of Coimbra, Department of Physics, Coimbra (Portugal); Bauermeister, B.; Fattori, S.; Geis, C.; Grignon, C.; Oberlack, U.; Schindler, S. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Beltrame, P. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); University of Edinburgh, Edinburgh (United Kingdom); Brown, A.; Lang, R.F.; Macmullin, S.; Pienaar, J.; Reichard, S.; Reuter, C. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Brown, E.; Levy, C. [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy, Troy, NY (United States); Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Bruenner, S.; Hampel, W.; Kaether, F.; Lindemann, S.; Lindner, M.; Undagoitia, T.M.; Rauch, L.; Schreiner, J.; Simgen, H.; Weber, M. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Bruno, G. [INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L' Aquila (Italy); Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Buetikofer, L.; Coderre, D.; Schumann, M. [University of Bern, Albert Einstein Center for Fundamental Physics, Bern (Switzerland); Colijn, A.P.; Decowski, M.P.; Tiseni, A.; Tunnell, C. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Cussonneau, J.P.; Le Calloch, M.; Masbou, J.; Lavina, L.S.; Thers, D. [Universite de Nantes, Subatech, Ecole des Mines de Nantes, CNRS/In2p3, Nantes (France); Ferella, A.D.; Fulgione, W.; Laubenstein, M. [INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L' Aquila (Italy); Fieguth, A.; Murra, M.; Rosendahl, S.; Weinheimer, C. [Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M. [Bologna Univ., Department of Physics and Astrophysics, Bologna (Italy); INFN, Bologna (Italy); Miguez, B.; Molinario, A.; Trinchero, G. [INFN-Torino and Osservatorio Astrofisico di Torino, Turin (Italy); Naganoma, J.; Shagin, P.; Wall, R. [Rice University, Department of Physics and Astronomy, Houston, TX (United States); Orrigo, S.E.A. [University of Coimbra, Department of Physics, Coimbra (Portugal); IFIC, CSIC-Universidad de Valencia, Valencia (Spain); Persiani, R. [Universite de Nantes, Subatech, Ecole des Mines de Nantes, CNRS/In2p3, Nantes (FR); Bologna Univ., Department of Physics and Astrophysics, Bologna (IT); INFN, Bologna (IT); Collaboration: XENON Collaboration

    2015-11-15

    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment. (orig.)

  7. Non-invasive evaluation of blood oxygen saturation and hematocrit from T1 and T2 relaxation times: In-vitro validation in fetal blood.

    Science.gov (United States)

    Portnoy, Sharon; Seed, Mike; Sled, John G; Macgowan, Christopher K

    2017-12-01

    We propose an analytical method for calculating blood hematocrit (Hct) and oxygen saturation (sO 2 ) from measurements of its T 1 and T 2 relaxation times. Through algebraic substitution, established two-compartment relationships describing R1=T1-1 and R2=T2-1 as a function of hematocrit and oxygen saturation were rearranged to solve for Hct and sO 2 in terms of R 1 and R 2 . Resulting solutions for Hct and sO 2 are the roots of cubic polynomials. Feasibility of the method was established by comparison of Hct and sO 2 estimates obtained from relaxometry measurements (at 1.5 Tesla) in cord blood specimens to ground-truth values obtained by blood gas analysis. Monte Carlo simulations were also conducted to assess the effect of T 1 , T 2 measurement uncertainty on precision of Hct and sO 2 estimates. Good agreement was observed between estimated and ground-truth blood properties (bias = 0.01; 95% limits of agreement = ±0.13 for Hct and sO 2 ). Considering the combined effects of biological variability and random measurement noise, we estimate a typical uncertainty of ±0.1 for Hct, sO 2 estimates. Results demonstrate accurate quantification of Hct and sO 2 from T 1 and T 2 . This method is applicable to noninvasive fetal vessel oximetry-an application where existing oximetry devices are unusable or require risky blood-sampling procedures. Magn Reson Med 78:2352-2359, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  9. SU-E-T-45: Antibody Mean Residence Time in Blood and Its Correlation with Protein Molecular Weight

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, C; Williams, L [Retired from City of Hope Medical Center, Arcadia, CA (United States)

    2014-06-01

    Purpose: Animal biodistribution data are required prior to introducing a new radiopharmaceutical into clinical trials. Protein engineering, using recombinant DNA techniques can produce a large number of related (cognate) antibodies to a given molecular target. Thus, it is important that these constructs be numerically related to one another via a single criterion. In the following, we use the mean residence time (MRT) in murine blood as this criterion. Methods: Five cognate anti-CEA (Carcinoembryonic Antigen) antibodies were compared with regard to their MRT in whole blood of CEA-positive tumor-bearing (LS174T) mice. MRT was defined by blood AUC (area under the curve) divided by the initial blood uptake value; all in units of percent injected dose per gram (%ID/g). Cognates included single chain scFv (25 kDa), diabody (50 kDa), minibody (80 kDa), F(ab')2 (120 kDa), and intact (155 kDa) forms of the murine cT84.66 antibody against CEA. All were labeled with radioactive iodine. Results: The agents, in the sequence listed, exhibited MRT values of 1.16 +/- 0.01 h, 0.99 h, 5.06 +/- 0.70 h, 6.61 +/- 0.36 h, and 59.3 +/- 2.4 h respectively. Because of the monotonic nature of the sequence, a linear correlation analysis was performed between molecular weight (MW) and MRT or ln(MRT) of the 5 proteins. Probability of random correlation was 0.10 for MRT and 0.01 for ln(MRT). Conclusion: MRT values of cognate anti-CEA antibodies were found to be a monotonically increasing sequence with respect to MW. Cognate MW values correlated best to ln(MRT) of the protein species. Thus MRT was proportional to an exponential function of molecular weight. The extended intact antibody circulation time presumably reflected its relatively maximal MW. Presence of an intact FC segment on this native antibody may also have influenced these results.

  10. SU-E-T-45: Antibody Mean Residence Time in Blood and Its Correlation with Protein Molecular Weight

    International Nuclear Information System (INIS)

    Kwok, C; Williams, L

    2014-01-01

    Purpose: Animal biodistribution data are required prior to introducing a new radiopharmaceutical into clinical trials. Protein engineering, using recombinant DNA techniques can produce a large number of related (cognate) antibodies to a given molecular target. Thus, it is important that these constructs be numerically related to one another via a single criterion. In the following, we use the mean residence time (MRT) in murine blood as this criterion. Methods: Five cognate anti-CEA (Carcinoembryonic Antigen) antibodies were compared with regard to their MRT in whole blood of CEA-positive tumor-bearing (LS174T) mice. MRT was defined by blood AUC (area under the curve) divided by the initial blood uptake value; all in units of percent injected dose per gram (%ID/g). Cognates included single chain scFv (25 kDa), diabody (50 kDa), minibody (80 kDa), F(ab')2 (120 kDa), and intact (155 kDa) forms of the murine cT84.66 antibody against CEA. All were labeled with radioactive iodine. Results: The agents, in the sequence listed, exhibited MRT values of 1.16 +/- 0.01 h, 0.99 h, 5.06 +/- 0.70 h, 6.61 +/- 0.36 h, and 59.3 +/- 2.4 h respectively. Because of the monotonic nature of the sequence, a linear correlation analysis was performed between molecular weight (MW) and MRT or ln(MRT) of the 5 proteins. Probability of random correlation was 0.10 for MRT and 0.01 for ln(MRT). Conclusion: MRT values of cognate anti-CEA antibodies were found to be a monotonically increasing sequence with respect to MW. Cognate MW values correlated best to ln(MRT) of the protein species. Thus MRT was proportional to an exponential function of molecular weight. The extended intact antibody circulation time presumably reflected its relatively maximal MW. Presence of an intact FC segment on this native antibody may also have influenced these results

  11. 5D.07: THE IMPACT OF FLAVONOL-RICH DARK CHOCOLATE ON BLOOD PRESSURE AND VASCULAR FUNCTION IN HEALTHY SUBJECTS.

    Science.gov (United States)

    Heuten, H; Van Ackeren, K; Hoymans, V; Wouters, K; Goovaerts, I; Conraads, V; Vrints, C

    2015-06-01

    Flavanoids may have a beneficial effect on blood pressure (BP) and endothelial function. There is however, limited data on this effect during a longer period (8 weeks) and no data on the effect on EPC (endothelial progenitor cells) in healthy subjects. Healthy, non-smoking, male and female volunteers aged 35-65 year with no history of diabetes or cardiovascular disease and with normal or mild hypertensive blood pressure (chocolate (High-DC). Group 2 (n = 26): daily consuming 20 gram of low-flavanol dark chocolate (Low-DC). At week 0,4,6,7 and 8 blood pressure was assessed in all subjects, and endothelial function (FMD, flow mediated dilation) in a subgroup. A blood sample was taken in each subject at week 0 and 8 for measuring glucose, lipids and EPC. Baseline characteristics were comparable between both groups. There was a decrease in systolic and diastolic blood pressure over time in both groups, however at 8 weeks there was no statistically significant difference between groups (delta SBP -2.17  + /-8.53 mmHg in gr 1 versus -4.06 + /-8.05 mmHg in gr 2, p = 0.4; delta DBP -3.97  + /-7.1 mmHg in gr 1 versus -4.67  + /-5.99 mmHg in gr 2, p = 0.7).FMD was performed in 9 subjects from each group, no significant difference was noted between both groups over time (delta FMD gr 1: -3.50  + /- 6.00 % versus gr 2: + 0.12  + /- 2.51 %, p = 0.06). EPC values did not differ between groups at baseline (T0) and at the end of the study (T8) (ISHAGE count (T8-T0): gr1: 3.23 (-68.01 - 41.71) versus gr 2: -9.23 (-57.59 - 17.28), p = 0.4). Glucose and lipids were comparable between both groups at baseline and at the end of the study (p = ns). In this study, no beneficial effect was noticed in favour of the consumption of flavanol-rich dark chocolate during 8 weeks on blood pressure or vascular function, in healthy subjects.

  12. James Webb Space Telescope Studies of Dark Energy

    Science.gov (United States)

    Gardner, Jonathan P.; Stiavelli, Massimo; Mather, John C.

    2010-01-01

    The Hubble Space Telescope (HST) has contributed significantly to studies of dark energy. It was used to find the first evidence of deceleration at z=1.8 (Riess et al. 2001) through the serendipitous discovery of a type 1a supernova (SN1a) in the Hubble Deep Field. The discovery of deceleration at z greater than 1 was confirmation that the apparent acceleration at low redshift (Riess et al. 1998; Perlmutter et al. 1999) was due to dark energy rather than observational or astrophysical effects such as systematic errors, evolution in the SN1a population or intergalactic dust. The GOODS project and associated follow-up discovered 21 SN1a, expanding on this result (Riess et al. 2007). HST has also been used to constrain cosmological parameters and dark energy through weak lensing measurements in the COSMOS survey (Massey et al 2007; Schrabback et al 2009) and strong gravitational lensing with measured time delays (Suyu et al 2010). Constraints on dark energy are often parameterized as the equation of state, w = P/p. For the cosmological constant model, w = -1 at all times; other models predict a change with time, sometimes parameterized generally as w(a) or approximated as w(sub 0)+(1-a)w(sub a), where a = (1+z)(sup -1) is the scale factor of the universe relative to its current scale. Dark energy can be constrained through several measurements. Standard candles, such as SN1a, provide a direct measurement of the luminosity distance as a function of redshift, which can be converted to H(z), the change in the Hubble constant with redshift. An analysis of weak lensing in a galaxy field can be used to derive the angular-diameter distance from the weak-lensing equation and to measure the power spectrum of dark-matter halos, which constrains the growth of structure in the Universe. Baryonic acoustic oscillations (BAO), imprinted on the distribution of matter at recombination, provide a standard rod for measuring the cosmological geometry. Strong gravitational lensing of a

  13. Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vertinsky, A.T. [Vancouver General Hospital, Department of Radiology, Vancouver (Canada); University of British Columbia, Department of Radiology, Vancouver (Canada); Rubesova, Erika; Bammer, Sabine; White, Allan; Barnes, Patrick D. [Stanford University Medical Center, Lucile Salter Packard Children' s Hospital, Palo Alto, CA (United States); Krasnokutsky, Michael V. [Madigan Army Medical Center, Department of Radiology, Tacoma, WA (United States); Uniformed Services University of Health Sciences, Department of Radiology, Bethesda, MD (United States); Rosenberg, Jarrett; Bammer, Roland [Lucas Center, Stanford University, Department of Radiology, Palo Alto, CA (United States)

    2009-10-15

    T2-weighted fast spin-echo imaging (T2-W FSE) is frequently degraded by motion in pediatric patients. MR imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) employs alternate sampling of k-space to achieve motion reduction. To compare T2-W PROPELLER FSE (T2-W PROP) with conventional T2-W FSE for: (1) image quality; (2) presence of artefacts; and (3) ability to detect lesions. Ninety-five pediatric patients undergoing brain MRI (1.5 T) were evaluated with T2-W FSE and T2-W PROP. Three independent radiologists rated T2-W FSE and T2-W PROP, assessing image quality, presence of artefacts, and diagnostic confidence. Chi-square analysis and Wilcoxon signed rank test were used to assess the radiologists' responses. Compared with T2-W FSE, T2-W PROP demonstrated better image quality and reduced motion artefacts, with the greatest benefit in children younger than 6 months. Although detection rates were comparable for the two sequences, blood products were more conspicuous on T2-W FSE. Diagnostic confidence was higher using T2-W PROP in children younger than 6 months. Average inter-rater agreement was 87%. T2-W PROP showed reduced motion artefacts and improved diagnostic confidence in children younger than 6 months. Thus, use of T2-W PROP rather than T2-W FSE should be considered in routine imaging of this age group, with caution required in identifying blood products. (orig.)

  14. Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI

    International Nuclear Information System (INIS)

    Vertinsky, A.T.; Rubesova, Erika; Bammer, Sabine; White, Allan; Barnes, Patrick D.; Krasnokutsky, Michael V.; Rosenberg, Jarrett; Bammer, Roland

    2009-01-01

    T2-weighted fast spin-echo imaging (T2-W FSE) is frequently degraded by motion in pediatric patients. MR imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) employs alternate sampling of k-space to achieve motion reduction. To compare T2-W PROPELLER FSE (T2-W PROP) with conventional T2-W FSE for: (1) image quality; (2) presence of artefacts; and (3) ability to detect lesions. Ninety-five pediatric patients undergoing brain MRI (1.5 T) were evaluated with T2-W FSE and T2-W PROP. Three independent radiologists rated T2-W FSE and T2-W PROP, assessing image quality, presence of artefacts, and diagnostic confidence. Chi-square analysis and Wilcoxon signed rank test were used to assess the radiologists' responses. Compared with T2-W FSE, T2-W PROP demonstrated better image quality and reduced motion artefacts, with the greatest benefit in children younger than 6 months. Although detection rates were comparable for the two sequences, blood products were more conspicuous on T2-W FSE. Diagnostic confidence was higher using T2-W PROP in children younger than 6 months. Average inter-rater agreement was 87%. T2-W PROP showed reduced motion artefacts and improved diagnostic confidence in children younger than 6 months. Thus, use of T2-W PROP rather than T2-W FSE should be considered in routine imaging of this age group, with caution required in identifying blood products. (orig.)

  15. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  16. Search for scalar dark energy in $t\\bar{t}+E_{T}^{\\text{miss}}$ and mono-jet final states with the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    This note presents the first collider search for light scalar particles that could contribute to the accelerating expansion of the observable universe. The results are based on a re-interpretation of a search for top super-partners using the $t\\bar{t}+E_{T}^{\\text{miss}}$ signature and a search for dark matter using the mono-jet signature. The analysis uses a dataset of LHC $pp$ collision events collected with the ATLAS detector at $\\sqrt{s}=13$ TeV corresponding to an integrated luminosity of 36.1~fb$^{-1}$. No significant excess over the predicted background is observed. The search allows to set the most stringent constraints on the suppression scale of conformal and disformal couplings of dark energy to standard model matter in the context of an effective field theory of dark energy.

  17. Mitigation of {sup 222}Rn induced background in the XENON1T dark matter experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bruenner, Stefan A.

    2017-07-05

    {sup 222}Rn is a major source of background in many rare-event experiments such as the XENON1T dark matter search. The noble gas radon is created by radioactive decay inside all detector materials and emanates into the sensitive liquid xenon target disabling any detector shielding. Subsequent beta-decays of radon progenies are the dominant source of background in the XENON1T experiment. In order to mitigate radon induced background the detector's construction materials have been selected according to dedicated {sup 222}Rn emanation measurements. In the first part of this thesis, we summarize the results of the XENON1T radon screening campaign and present the measurement of the integral radon emanation rate of the fully assembled detector. The development of a radon removal system which continuously purifies the liquid xenon target from the emanated radon is the topic of the second part of this thesis. In order to demonstrate the suitability of cryogenic distillation as a technique to separate radon from xenon, we developed an experimental setup to measure the depletion of radon in xenon boil-off gas after a single distillation step. In the last part of the thesis, we demonstrate the operation of a radon removal system for the XENON100 experiment. For this first test employing a running dark matter detector, we integrated a multiple stage, cryogenic distillation column in the XENON100 gas purification loop. From the evolution of the radon concentration in XENON100, we investigate the distillation column's radon removal capability and discuss the design and application of a radon removal system for XENON1T and the upcoming XENONnT experiment.

  18. Metastatic spinal tumor. Assessment with fat-saturation T1-weighted MR imaging

    International Nuclear Information System (INIS)

    Kasai, Toshifumi; Sugimura, Kazuro; Uchida, Nobue; Kawamitsu, Hideaki; Komatsu, Akio; Okui, Shouji; Kimino, Katsuji.

    1994-01-01

    The purpose of this study was to compare conventional T1-weighted imaging (T1-WI) and chemical shift fat-saturation T1-weighted imaging (fat-sat T1-WI) by a diagnosis of the bone metastases. Thirty-two patients (143 vertebrae) with non-neoplastic lesions (normal group) and 32 patients (82 vertebrae) with spinal metastases (metastatic group) were evaluated using both images. The signal intensity (SI) distribution of both groups regarding T1-WI provided various patterns, and the SI measurements were not significantly different between the two groups ; however, the metastases which were mixed, showed a low SI. Regarding fat-sat T1-WI, all non-neoplastic lesions had a low-intensity homogeneous appearance ; however, the metastases were mixed to a high SI. The SI measurement data of the metastatic group was significantly higher than that of the normal group. In conclusion, fat-sat T1-WI was useful for evaluating the vertebral metastases. When fat-sat T1-WI demonstrated a mixed to high SI in patients suspected of having vertebral metastasis, Gd-DTPA enhancement was thought to be the problem. (author)

  19. Extracellular space, blood volume, and the early dumping syndrome after total gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Miholic, J.; Reilmann, L.; Meyer, H.J.; Koerber, H.K.; Kotzerke, J.; Hecker, H. (Medzinische Hochschule Hannover (Germany, F.R.))

    1990-10-01

    Extracellular space and blood volume were measured using 82Br dilution and 51Cr-tagged erythrocytes in 24 tumor-free patients after total gastrectomy. Eleven of the patients suffered from early dumping. Age, blood volume, and extracellular space were significantly smaller in dumpers (P less than 0.05). The dumping score could be predicted by a multiple regression model considering blood volume per lean body mass and extracellular space (r = 0.637; P = 0.0039). Rapid (t1/2 less than 360 seconds) emptying of the gastric substitute, assessed using a 99Tc-labeled solid test meal, was significantly associated with dumping in addition to extracellular space and blood volume (r = 0.876; P = 0.0018). Both rapid emptying and a narrow extracellular space seem to contribute to the early dumping syndrome.

  20. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

    Directory of Open Access Journals (Sweden)

    Sonja Kinner

    Full Text Available Preoperative evaluation of potential living liver donors (PLLDs includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w and Gd-EOB-DTPA enhanced T1-weighted (T1w magnetic resonance cholangiography (MRC techniques in the evaluation of PLLDs.30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany using (A 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo fat saturated (fs in axial plane, (B 2D T2w HASTE fs thick slices in coronal plane, (C free breathing 3D T2w TSE (turbo spin echo RESTORE (high-resolution navigator corrected plus (D maximum intensity projections (MIPs, (E T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions plus (F MIPs and (G T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G and with (H inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated.Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622-0.804.3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.

  1. The phase-space structure of a dark-matter halo: Implications for dark-matter direct detection experiments

    International Nuclear Information System (INIS)

    Helmi, Amina; White, Simon D.M.; Springel, Volker

    2002-01-01

    We study the phase-space structure of a dark-matter halo formed in a high resolution simulation of a ΛCDM cosmology. Our goal is to quantify how much substructure is left over from the inhomogeneous growth of the halo, and how it may affect the signal in experiments aimed at detecting the dark matter particles directly. If we focus on the equivalent of 'solar vicinity', we find that the dark matter is smoothly distributed in space. The probability of detecting particles bound within dense lumps of individual mass less than 10 7 M · h -1 is small, less than 10 -2 . The velocity ellipsoid in the solar neighborhood deviates only slightly from a multivariate Gaussian, and can be thought of as a superposition of thousands of kinematically cold streams. The motions of the most energetic particles are, however, strongly clumped and highly anisotropic. We conclude that experiments may safely assume a smooth multivariate Gaussian distribution to represent the kinematics of dark-matter particles in the solar neighborhood. Experiments sensitive to the direction of motion of the incident particles could exploit the expected anisotropy to learn about the recent merging history of our Galaxy

  2. Postcontrast T1-weighted brain magnetic resonance imaging in pediatric patients: comparison between postcontrast fat-suppression imaging and conventional T1-weighted or magnetization transfer imaging

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Goo, Hyun Woo

    2004-01-01

    We wished to assess the merits and weaknesses of postcontrast fat-suppression (FS) brain MR imaging in children for the evaluation of various enhancing lesions as compared with postcontrast conventional T1-weighted or magnetization transfer (MT) imaging. We reviewed the records of those patients with enhancing lesions on brain MR imaging who had undergone both FS imaging and one of the conventional T1-weighted or MT imaging as a post-contrast T1-weighted brain MR imaging. Thirty-one patients (21 male, 10 female; mean age, 8.7 years) with 38 enhancing lesions (18 intra-axial, 16 extra-axial and 4 orbital locations) were included in this study. There were 27 pairs of FS and conventional imagings, and 13 pairs of FS and MT imagings available for evaluation. Two radiologists visually assessed by consensus the lesions' conspicuity, and they also looked for the presence of flow or susceptibility artifacts in a total of 40 pairs of MR imagings. For 19 measurable lesions (14 pairs of FS and conventional T1-weighted imagings, 5 pairs of FS and MT imagings), the contrast ratios between the lesion and the normal brain ([SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared. Compared with conventional imaging, the lesion conspicuity on FS imaging was better in 10 cases (7 extra-axial lesions, 2 orbital lesions and 1 fat-containing intra-axial lesion), equal in 16 cases, and worse in one case. Compared with MT imaging, the lesion conspicuity on FS imaging was better in 3 cases (2 extra-axial lesions and 1 intra-axial lesion), equal in 8 cases, and worse in 2 cases. Image quality of FS imaging was compromised by flow or susceptibility artifacts for 7 patients. The contrast ratios for FS imaging were not significantly different from those for conventional imaging (2.2±0.7 vs. 2.2±0.6, respectively, p=0.914) and they were significantly lower than those for MT imaging (2.4±0.8 vs. 4.5±1.5, respectively, p=0.018). Postcontrast FS brain MR imaging appears to be

  3. The value of T1-weighted images in the differentiation between MS, white matter lesions, and subcortical arteriosclerotic encephalopathy (SAE)

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Sehlen, S.

    1989-07-01

    The aim of the study was to define reliable criteria for the differentiation of MR imaging between patients with MS and with 'vascular' white matter lesions/SAE. We examined 35 patients with proven MS according to the Poser criteria and 35 patients with other white matter lesions and/or SAE. The result is that with MR a differentiation can be achieved provided that T1-weighted spin-echo sequences are included and the different pattern of distribution is considered. MS plaques are predominantly located in the subependymal region, vascular white matter lesions are mainly located in the water-shed of the superficial middle cerebral branches and the deep perforating long medullary vessels in the centrum semiovale. Infratentorial lesions are more often seen in MS. Confluence at the lateral ventricles is frequently accompanied by confluent abnormalities around the third ventricle, Sylvian aqueduct, and fourth ventricle, which is uncommon in SAE. In MS many lesions visible on T2-weighted images have a cellular or intracellular composition that renders them visible also on T1-weighted ones as regions with low signal intensity and more or less distinct boundary. 'Vascular' white matter lesions and SAE mainly represent demyelination and can therefore be seen on T2-weighted images, but corresponding low signal intensity lesions on T1-weighted images are uncommon. In some exceptions there are such lesions with low signal representing lacunar infarcts or widened Virchow-Robin-spaces. (orig.).

  4. ``Smart'' theranostic lanthanide nanoprobes with simultaneous up-conversion fluorescence and tunable T1-T2 magnetic resonance imaging contrast and near-infrared activated photodynamic therapy

    Science.gov (United States)

    Zhang, Yan; Das, Gautom Kumar; Vijayaragavan, Vimalan; Xu, Qing Chi; Padmanabhan, Parasuraman; Bhakoo, Kishore K.; Tamil Selvan, Subramanian; Tan, Timothy Thatt Yang

    2014-10-01

    The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent.The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr01717j

  5. The Effects of Dark Chocolate Consumption on Oxidative Stress and Blood Pressure in Patients with Metabolic Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Hassan Mozaffari-Khosravi

    2016-10-01

    Full Text Available Background: Consumption of dark chocolate has been often hypothesized to have a role in the prevention of chronic diseases. The objective of this study was to investigate the effects of consumption of dark chocolate (DC on serum oxidative stress and blood pressure (BP in patients with metabolic syndrome (MetS. Methods: An 8-week parallel randomized clinical trial involving 114 patients with MetS was conducted on stable medication in 2014. Participants were randomly assigned to three groups: 1 consume 40 g/d DC (40G, 2 consume 20 g/d DC (20G, and 3 consume no DC as the control group (CG. BP, radical scavenging activity of 1-diphenyl-2-picrylhydrazyl (DPPH, and malondialdehyde (MDA were measured at baseline and after 8 weeks of intervention. Results: Mean age, weight, and body mass index (BMI of participants were 51.38 ± 6.95 y, 77.34 ± 12.86 kg, and 28.65 ± 4.4 kg/m2, respectively. No significant differences were found among the three groups in relation to these variables after the intervention. The mean change of systolic blood pressure in 40G, 20G, and CG were 0.31 ± 1.81, 0.37 ± 1.65, and 0.26 ± 1.56 mmHg (P = 0.3, respectively. These figures for diastolic blood pressure were obtained as 0.08 ± 1.03, -0.02 ± 1.12, and 0.22 ± 1.03 mmHg. No significant changes were observed in MDA and DPPH between three groups. Conclusion: Even daily intake of 40 g of DC with 76% purity for an 8-week period had no effect on body weight, BMI, BP, and oxidative stress in patients with MetS.

  6. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    Science.gov (United States)

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  7. Characterization of associate spaces of weighted Lorentz spaces with applications

    Czech Academy of Sciences Publication Activity Database

    Gogatishvili, Amiran; Pick, L.; Soudský, F.

    2014-01-01

    Roč. 224, č. 1 (2014), s. 1-23 ISSN 0039-3223 R&D Projects: GA ČR GA13-14743S Institutional support: RVO:67985840 Keywords : weighted Lorentz spaces * weighted inequalities * non-increasing rearragement * Banach function space Subject RIV: BA - General Mathematics Impact factor: 0.610, year: 2014 http://journals.impan.gov.pl/sm/Inf/224-1-1.html

  8. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    Science.gov (United States)

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (PCHESS sequence and the 3D FSE T1-weighted CHESS sequence (PCHESS sequence (PCHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (PCHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  9. Weighted Composition Operators from Hardy Spaces into Logarithmic Bloch Spaces

    Directory of Open Access Journals (Sweden)

    Flavia Colonna

    2012-01-01

    Full Text Available The logarithmic Bloch space Blog⁡ is the Banach space of analytic functions on the open unit disk &#x1D53B; whose elements f satisfy the condition ∥f∥=sup⁡z∈&#x1D53B;(1-|z|2log⁡  (2/(1-|z|2|f'(z|<∞. In this work we characterize the bounded and the compact weighted composition operators from the Hardy space Hp (with 1≤p≤∞ into the logarithmic Bloch space. We also provide boundedness and compactness criteria for the weighted composition operator mapping Hp into the little logarithmic Bloch space defined as the subspace of Blog⁡ consisting of the functions f such that lim⁡|z|→1(1-|z|2log⁡  (2/(1-|z|2|f'(z|=0.

  10. T1-weighted MRI for the detection of coronary artery plaque haemorrhage

    International Nuclear Information System (INIS)

    Oei, May Lin; Ozgun, Murat; Seifarth, Harald; Bunck, Alexander; Fischbach, Roman; Heindel, Walter; Maintz, David; Orwat, Stefan; Botnar, Rene

    2010-01-01

    Hyperintense areas in atherosclerotic plaques on pre-contrast T1-weighted MRI have been shown to correlate with intraplaque haemorrhage. We evaluated the presence of T1 hyperintensity in coronary artery plaques in coronary artery disease (CAD) patients and correlated results with multi-detector computed tomography (MDCT) findings. Fifteen patients with CAD were included. Plaques detected by MDCT were categorised based on their Hounsfield number. T1-weighted inversion recovery (IR) MRI prepared coronary MRI for the detection of plaque and steady-state free-precession coronary MR-angiography for anatomical correlation was performed. After registration of MDCT and MRI, regions of interest were defined on MDCT-visible plaques and in corresponding vessel segments acquired with MRI. MDCT density and MR signal measurement were performed in each plaque. Forty-three plaques were identified with MDCT. With IR-MRI 5/43 (12%) plaques were hyperintense, 2 of which were non-calcified and 3 mixed. Average signal-to-noise and contrast-to-noise ratios of hyperintense plaques were 15.7 and 9.1, compared with 5.6 and 1.2 for hypointense plaques. Hyperintense plaques exhibited a significantly lower CT density than hypointense plaques (63.6 vs. 140.8). There was no correlation of plaque signal intensity with degree of stenosis. T1-weighted IR-MRI may be useful for non-invasive detection and characterisation of intraplaque haemorrhage in coronary artery plaques. (orig.)

  11. Two-singlet model for light cold dark matter

    International Nuclear Information System (INIS)

    Abada, Abdessamad; Ghaffor, Djamal; Nasri, Salah

    2011-01-01

    We extend the standard model by adding two gauge-singlet Z 2 -symmetric scalar fields that interact with visible matter only through the Higgs particle. One is a stable dark matter WIMP, and the other one undergoes a spontaneous breaking of the symmetry that opens new channels for the dark matter annihilation, hence lowering the mass of the WIMP. We study the effects of the observed dark matter relic abundance on the WIMP annihilation cross section and find that in most regions of the parameters' space, light dark matter is viable. We also compare the elastic-scattering cross section of our dark matter candidate off a nucleus with existing (CDMSII and XENON100) and projected (SuperCDMS and XENON1T) experimental exclusion bounds. We find that most of the allowed mass range for light dark matter will be probed by the projected sensitivity of the XENON1T experiment.

  12. Little composite dark matter

    Science.gov (United States)

    Balkin, Reuven; Perez, Gilad; Weiler, Andreas

    2018-02-01

    We examine the dark matter phenomenology of a composite electroweak singlet state. This singlet belongs to the Goldstone sector of a well-motivated extension of the Littlest Higgs with T-parity. A viable parameter space, consistent with the observed dark matter relic abundance as well as with the various collider, electroweak precision and dark matter direct detection experimental constraints is found for this scenario. T-parity implies a rich LHC phenomenology, which forms an interesting interplay between conventional natural SUSY type of signals involving third generation quarks and missing energy, from stop-like particle production and decay, and composite Higgs type of signals involving third generation quarks associated with Higgs and electroweak gauge boson, from vector-like top-partners production and decay. The composite features of the dark matter phenomenology allows the composite singlet to produce the correct relic abundance while interacting weakly with the Higgs via the usual Higgs portal coupling λ _{ {DM}}˜ O(1%), thus evading direct detection.

  13. Little composite dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Balkin, Reuven; Weiler, Andreas [Technische Universitaet Muenchen, First Physik-Department, Garching (Germany); Perez, Gilad [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel)

    2018-02-15

    We examine the dark matter phenomenology of a composite electroweak singlet state. This singlet belongs to the Goldstone sector of a well-motivated extension of the Littlest Higgs with T-parity. A viable parameter space, consistent with the observed dark matter relic abundance as well as with the various collider, electroweak precision and dark matter direct detection experimental constraints is found for this scenario. T-parity implies a rich LHC phenomenology, which forms an interesting interplay between conventional natural SUSY type of signals involving third generation quarks and missing energy, from stop-like particle production and decay, and composite Higgs type of signals involving third generation quarks associated with Higgs and electroweak gauge boson, from vector-like top-partners production and decay. The composite features of the dark matter phenomenology allows the composite singlet to produce the correct relic abundance while interacting weakly with the Higgs via the usual Higgs portal coupling λ{sub DM} ∝ O(1%), thus evading direct detection. (orig.)

  14. Gravity mediated Dark Matter models in the de Sitter space

    OpenAIRE

    Vancea, Ion V.

    2018-01-01

    In this paper, we generalize the simplified Dark Matter models with graviton mediator to the curved space-time, in particular to the de Sitter space. We obtain the generating functional of the Green's functions in the Euclidean de Sitter space for the covariant free gravitons. We determine the generating functional of the interacting theory between Dark Matter particles and the covariant gravitons. Also, we calculate explicitly the 2-point and 3-point interacting Green's functions for the sym...

  15. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S. [Univ. Hospital of Regensburg (Germany). Dept. of Diagnostic Radiology; Stamato, S. [Univ. of California, San Diego, CA (United States). Dept. of Radiology

    2002-07-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

  16. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S.; Stamato, S.

    2002-01-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage

  17. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    International Nuclear Information System (INIS)

    Ganzetti, Marco; Mantini, Dante; Wenderoth, Nicole

    2015-01-01

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  18. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Ganzetti, Marco; Mantini, Dante [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); University of Oxford, Department of Experimental Psychology, Oxford (United Kingdom); Wenderoth, Nicole [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); KU Leuven, Laboratory of Movement Control and Neuroplasticity, Faculty of Kinesiology and Rehabilitation Sciences, Leuven (Belgium)

    2015-09-15

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  19. Detailed T1-Weighted Profiles from the Human Cortex Measured in Vivo at 3 Tesla MRI.

    Science.gov (United States)

    Ferguson, Bart; Petridou, Natalia; Fracasso, Alessio; van den Heuvel, Martijn P; Brouwer, Rachel M; Hulshoff Pol, Hilleke E; Kahn, René S; Mandl, René C W

    2018-04-01

    Studies into cortical thickness in psychiatric diseases based on T1-weighted MRI frequently report on aberrations in the cerebral cortex. Due to limitations in image resolution for studies conducted at conventional MRI field strengths (e.g. 3 Tesla (T)) this information cannot be used to establish which of the cortical layers may be implicated. Here we propose a new analysis method that computes one high-resolution average cortical profile per brain region extracting myeloarchitectural information from T1-weighted MRI scans that are routinely acquired at a conventional field strength. To assess this new method, we acquired standard T1-weighted scans at 3 T and compared them with state-of-the-art ultra-high resolution T1-weighted scans optimised for intracortical myelin contrast acquired at 7 T. Average cortical profiles were computed for seven different brain regions. Besides a qualitative comparison between the 3 T scans, 7 T scans, and results from literature, we tested if the results from dynamic time warping-based clustering are similar for the cortical profiles computed from 7 T and 3 T data. In addition, we quantitatively compared cortical profiles computed for V1, V2 and V7 for both 7 T and 3 T data using a priori information on their relative myelin concentration. Although qualitative comparisons show that at an individual level average profiles computed for 7 T have more pronounced features than 3 T profiles the results from the quantitative analyses suggest that average cortical profiles computed from T1-weighted scans acquired at 3 T indeed contain myeloarchitectural information similar to profiles computed from the scans acquired at 7 T. The proposed method therefore provides a step forward to study cortical myeloarchitecture in vivo at conventional magnetic field strength both in health and disease.

  20. Bilateral hyperintense basal ganglia on T1-weighted image

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Ahn, Woo Hyun; Choi, Han Yong; Kim, Bong Gi

    1994-01-01

    Bilateral high signal intensity in basal ganglia on T1-weighted images is unusual, the purpose of this study is to describe the pattern of high signal intensity and underlying disease. During the last three years, 8 patients showed bilateral high signal intensity in basal ganglia on T1-weighted image, as compared with cerebral white matter. Authors analyzed the images and underlying causes retrospectively. Of 8 patients, 5 were male and 3 were female. The age ranged from 15 days to 79 years. All patient were examined by a 0.5T superconductive MRI. Images were obtained by spin echo multislice technique. Underlying causes were 4 cases of hepatopathy, 2 cases of calcium metabolism disorder, and one case each of neurofibromatosis and hypoxic brain injury. These process were bilateral in all cases and usually symmetric. In all cases the hyperintense areas were generally homogenous without mass effect or edema, although somewhat nodular appearance was seen in neurofibromatosis. Lesions were located in the globus pallidus and internal capsule in hepatopathy and neurofibromatosis, head of the caudate nucleus in disorder of calcum metabolism, and the globus pallidus in hypoxic brain injury. Although this study is limited by its patient population, bilateral hyperintense basal ganglia is associated with various disease entities. On analysis of hyperintense basal ganglia lesion, the knowledge of clinical information improved diagnostic accuracy

  1. Dark Matter

    Science.gov (United States)

    Lincoln, Don

    2013-01-01

    It's a dark, dark universe out there, and I don't mean because the night sky is black. After all, once you leave the shadow of the Earth and get out into space, you're surrounded by countless lights glittering everywhere you look. But for all of Sagan's billions and billions of stars and galaxies, it's a jaw-dropping fact that the ordinary kind of…

  2. Supersymmetric dark matter after LHC run 1

    International Nuclear Information System (INIS)

    Bagnaschi, E.A.; Buchmueller, O.; Cavanaugh, R.; Illinois Univ., Chicago, IL

    2015-08-01

    Different mechanisms operate in various regions of the MSSM parameter space to bring the relic density of the lightest neutralino, χ 0 1 , assumed here to be the LSP and thus the Dark Matter (DM) particle, into the range allowed by astrophysics and cosmology. These mechanisms include coannihilation with some nearly-degenerate next-to-lightest supersymmetric particle (NLSP) such as the lighter stau τ 1 , stop t 1 or chargino χ ± 1 , resonant annihilation via direct-channel heavy Higgs bosons H/A, the light Higgs boson h or the Z boson, and enhanced annihilation via a larger Higgsino component of the LSP in the focus-point region. These mechanisms typically select lower-dimensional subspaces in MSSM scenarios such as the CMSSM, NUHM1, NUHM2 and pMSSM10. We analyze how future LHC and direct DM searches can complement each other in the exploration of the different DM mechanisms within these scenarios. We find that the τ 1 coannihilation regions of the CMSSM, NUHM1, NUHM2 can largely be explored at the LHC via searches for missing E T events and long-lived charged particles, whereas their H/A funnel, focus-point and χ ± 1 coannihilation regions can largely be explored by the LZ and Darwin DM direct detection experiments. We find that the dominant DM mechanism in our pMSSM10 analysis is χ ± 1 coannihilation: parts of its parameter space can be explored by the LHC, and a larger portion by future direct DM searches.

  3. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Mahon, R; Weiss, E; Karki, K; Hugo, G; Ford, J

    2016-01-01

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  4. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    Energy Technology Data Exchange (ETDEWEB)

    Mahon, R; Weiss, E; Karki, K; Hugo, G [Virginia Commonwealth University, Richmond, VA (United States); Ford, J [University of Miami Miller School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  5. Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences.

    Science.gov (United States)

    Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik

    2018-01-01

    To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.

  6. Dark chocolate or tomato extract for prehypertension: a randomised controlled trial.

    Science.gov (United States)

    Ried, Karin; Frank, Oliver R; Stocks, Nigel P

    2009-07-08

    Flavanol-rich chocolate and lycopene-rich tomato extract have attracted interest as potential alternative treatment options for hypertension, a known risk factor for cardiovascular morbidity and mortality. Treatment of prehypertension (SBP 120-139/DBP 80-89 mmHg) may forestall progression to hypertension. However, there has been only limited research into non-pharmacological treatment options for prehypertension. We investigated the effect of dark chocolate or tomato extract on blood pressure, and their acceptability as an ongoing treatment option in a prehypertensive population. Our trial consisted of two phases: a randomised controlled three-group-parallel trial over 12 weeks (phase 1) followed by a crossover of the two active treatment arms over an additional 12-week period (phase 2). Group 1 received a 50 g daily dose of dark chocolate with 70% cocoa containing 750 mg polyphenols, group 2 were allocated one tomato extract capsule containing 15 mg lycopene per day, and group 3 received one placebo capsule daily over 8 weeks followed by a 4-week washout period. In phase 2 the active treatment groups were crossed over to receive the alternative treatment. Median blood pressure, weight, and abdominal circumference were measured 4-weekly, and other characteristics including physical activity, general health, energy, mood, and acceptability of treatment were assessed by questionnaire at 0, 8 and 20 weeks. We analysed changes over time using a linear mixed model, and one time point differences using Kruskal-Wallis, Fisher's-Exact, or t-tests. Thirty-six prehypertensive healthy adult volunteers completed the 6-month trial. Blood pressure changes over time within groups and between groups were not significant and independent of treatment. Weight and other characteristics did not change significantly during the trial. However, a marked difference in acceptability between the two treatment forms (chocolate or capsule) was revealed (p chocolate treatment found it hard to

  7. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

    DEFF Research Database (Denmark)

    Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.

    2008-01-01

    Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast...... field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed...... inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values...

  8. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  9. Weighted composition operators from Bergman-type spaces into ...

    Indian Academy of Sciences (India)

    Weighted composition operators from Bergman-type spaces into Bloch spaces and little. Bloch spaces are characterized by function theoretic properties of their inducing maps. Keywords. Weighted composition operator; Bergman-type space; Bloch space. 1. Introduction. Let D be the open unit disk in the complex plane C.

  10. T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); UMR INSERM 965, Hôpital Lariboisière, 2 Rue Amboise Paré, 75010 Paris (France); Gavini, Jean-Philippe, E-mail: jpgavini@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Placé, Vinciane, E-mail: vinciane.place@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sebbag, Delphine, E-mail: delphinesebbag@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Vignaud, Alexandre, E-mail: alexandre.vignaud@cea.fr [LRMN, Neurospin, CEA-SACLAY, Bâtiment 145, 91 191 Gif-sur-Yvette Cedex (France); and others

    2013-11-01

    Objective: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. Materials and methods: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. Results: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median = 22.82) than TSE MR imaging (median = 14.15) (P < .001). No differences were found for SNR of hepatic parenchyma (P = .097), main focal hepatic lesions (P = .35), and splenic parenchyma (P = .25). SPACE sequence showed less artifacts than TSE sequence (vascular, P < .001; respiratory motion, P < .001; cardiac, P < .001) but needed a longer acquisition time (228.4 vs. 162.1 s; P < .001). Conclusion: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.

  11. The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides.

    Science.gov (United States)

    Cao, Limin; Li, Binbin; Yi, Peiwei; Zhang, Hailu; Dai, Jianwu; Tan, Bo; Deng, Zongwu

    2014-04-01

    Three Gd-DOTA-peptide complexes with different peptide sequence are synthesized and used as T1 contrast agent to label human mesenchymal stem cells (hMSCs) for magnetic resonance imaging study. The peptides include a universal cell penetrating peptide TAT, a linear MSC-specific peptide EM7, and a cyclic MSC-specific peptide CC9. A significant difference in labeling efficacy is observed between the Gd-DOTA-peptides as well as a control Dotarem. All Gd-DOTA-peptides as well as Dotarem induce significant increase in T1 relaxation rate which is in favor of T1-weighted MR imaging. Gd-DOTA-CC9 yields the maximum labeling efficacy but poor T1 contrast enhancement. Gd-DOTA-EM7 yields the minimum labeling efficacy but better T1 contrast enhancement. Gd-DOTA-TAT yields a similar labeling efficacy as Gd-DOTA-CC9 and similar T1 contrast enhancement as Gd-DOTA-EM7. The underlying mechanism that governs T1 contrast enhancement effect is discussed. Our results suggest that T1 contrast enhancement induced by Gd-DOTA-peptides depends not only on the introduced cellular Gd content, but more importantly on the effect that Gd-DOTA-peptides exert on the T1-relaxation and T2-relaxation processes/rates. Both T1 and particularly T2 relaxation rate have to be taken into account to interpret T1 contrast enhancement. In addition, the interpretation has to be based on cellular instead of aqueous longitudinal and transverse relaxivities of Gd-DOTA-peptides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    Science.gov (United States)

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  13. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  14. Dark blood versus bright blood T2* acquisition in cardiovascular magnetic resonance (CMR) for thalassaemia major (TM) patients: Evaluation of feasibility, reproducibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Liguori, Carlo, E-mail: c.liguori@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Di Giampietro, Ilenia; Pitocco, Francesca; De Vivo, Aldo Eros [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Schena, Emiliano [Unit of Measurements and Biomedical Instrumentation, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Mortato, Luca [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Pirro, Federica [Department of Biomaging and Radiological Sciences, Catholic University of Sacred Herart, Largo A. Gemelli 1, 00135 Rome (Italy); Cianciulli, Paolo [Thalassemia Unit, Ospedale Sant Eugenio, Piazzale dell’Umanesimo 10, 00143 Rome (Italy); Zobel, Bruno Beomonte [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy)

    2014-01-15

    Objectives: To compare the effectiveness of dark blood (DB) versus bright blood (BB) sequences. To assess the intra and inter-observer variability and inter-study reproducibility between BB versus DB. To evaluate image quality level in the two sequences. Methods: In a setting of 138 patients we performed CMR using cardiac gated Gradient-multiecho single breath-hold BB and DB sequences in the middle ventricular septum. Each acquisition was repeated during the same exam. Truncation method was used to account for background noise. Image quality (IQ) was assessed using a 5 point grading scale and image analysis was conducted by 2 experienced observers. Results: Compared with the conventional BB acquisition, the coefficient of correlation and significance of the DB technique was superior for intra-observer reproducibility (p < 0.001), inter-observer reproducibility (p < 0.001) and inter-study reproducibility (p < 0.001). The variability is also lower for DB sequences for T2* values <14 ms. Assessment of artifacts showed a superior score for DB versus BB scans (4 versus 3, p < 0.001). Conclusions: Improvement in terms of inter observer and inter study variability using DB sequences was obtained. The greatest disparity between them was seen in inter-study reproducibility and higher IQ in DB was seen. Study demonstrates better performance of DB imaging compared to BB in presence of comparable effectiveness.

  15. Clinical Study White Matter Atrophy in Patients with Mesial Temporal Lobe Epilepsy: Voxel-Based Morphometry Analysis of T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Braga, B.; Yasuda, C.L.; Cendes, F.

    2012-01-01

    Introduction. Mesial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis is highly refractory to clinical treatment. MRI voxel-based morphometry (VBM) of T1-weighted images has revealed a widespread pattern of gray matter (GM) and white matter (WM) atrophy in MTLE. Few studies have investigated the role of T2-weighted images in revealing WM atrophy using VBM. Objectives. To compare the results of WM atrophy between T1- and T2-weighted images through VBM. Methods. We selected 28 patients with left and 27 with right MTLE and 60 normal controls. We analyzed T1- and T2- weighted images with SPM8, using VBM/DARTEL algorithm to extract maps of GM and WM. The second level of SPM was used to investigate areas of WM atrophy among groups. Results. Both acquisitions showed bilateral widespread WM atrophy. T1-weighted images showed higher sensibility to detect areas of WM atrophy in both groups of MTLE. T2-weighted images also showed areas of WM atrophy in a more restricted pattern, but still bilateral and with a large area of superposition with T1-weighted images. Conclusions. In MTLE, T1-weighted images are more sensitive to detect subtle WM abnormalities using VBM, compared to T2 images, although both present a good superposition of statistical maps. 1. Introduction The mesial temporal lobe epilepsy (MTLE) is highly refractory to pharmacological treatment [1], and it is the main group of epilepsy referred to the tertiary care hospitals for surgical treatment [2]. MTLE shows a good surgical prognosis, with satisfactory seizures control in 60-80% of the patients [3]. In approximately 65%

  16. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    Science.gov (United States)

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  17. Optimisation of T2*-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    International Nuclear Information System (INIS)

    Dixon, Jennifer Elizabeth; Simpson, Ashley; Mistry, Niraj; Evangelou, Nikos; Morris, Peter Gordon

    2013-01-01

    T 2 * -weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T 2 * -weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions

  18. T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-06-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as "intensity field bias". Such inhomogeneities mostly originate from heterogeneous RF coil B(1) profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T(1)-weighted (T(1)w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T(1) weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T(1) contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B(1) variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B(1) profiles become more heterogeneous. Another characteristic of T(1)w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T(2)(*) contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T(1)w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T(2)(*) contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 T, provide higher T(1) contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help in identifying small brain structures and that T(2)(*) induced artifacts can be removed from the images. The resulting unbiased T(1)w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T(1)w structural images. In addition

  19. Light dark Higgs boson in minimal sub-GeV dark matter scenarios

    Science.gov (United States)

    Darmé, Luc; Rao, Soumya; Roszkowski, Leszek

    2018-03-01

    Minimal scenarios with light (sub-GeV) dark matter whose relic density is obtained from thermal freeze-out must include new light mediators. In particular, a very well-motivated case is that of a new "dark" massive vector gauge boson mediator. The mass term for such mediator is most naturally obtained by a "dark Higgs mechanism" which leads to the presence of an often long-lived dark Higgs boson whose mass scale is the same as that of the mediator. We study the phenomenology and experimental constraints on two minimal, self-consistent dark sectors that include such a light dark Higgs boson. In one the dark matter is a pseudo-Dirac fermion, in the other a complex scalar. We find that the constraints from BBN and CMB are considerably relaxed in the framework of such minimal dark sectors. We present detection prospects for the dark Higgs boson in existing and projected proton beam-dump experiments. We show that future searches at experiments like Xenon1T or LDMX can probe all the relevant parameter space, complementing the various upcoming indirect constraints from astrophysical observations.

  20. Cord Blood Metabolome Is Highly Associated with Birth Weight, but Less Predictive for Later Weight Development

    Directory of Open Access Journals (Sweden)

    Christian Hellmuth

    2017-04-01

    Full Text Available Background/Aims: Fetal metabolism may be changed by the exposure to maternal factors, and the route to obesity may already set in utero. Cord blood metabolites might predict growth patterns and later obesity. We aimed to characterize associations of cord blood with birth weight, postnatal weight gain, and BMI in adolescence. Methods: Over 700 cord blood samples were collected from infants participating in the German birth cohort study LISAplus. Glycerophospholipid fatty acids (GPL-FA, polar lipids, non-esterified fatty acids (NEFA, and amino acids were analyzed with a targeted, liquid chromatography-tandem mass spectrometry based metabolomics platform. Cord blood metabolites were related to growth factors by linear regression models adjusted for confounding variables. Results: Cord blood metabolites were highly associated with birth weight. Lysophosphatidylcholines C16:1, C18:1, C20:3, C18:2, C20:4, C14:0, C16:0, C18:3, GPL-FA C20:3n-9, and GPL-FA C22:5n-6 were positively related to birth weight, while higher cord blood concentrations of NEFA C22:6, NEFA C20:5, GPL-FA C18:3n-3, and PCe C38:0 were associated with lower birth weight. Postnatal weight gain and BMI z-scores in adolescents were not significantly associated with cord blood metabolites after adjustment for multiple testing. Conclusion: Potential long-term programming effects of the intrauterine environment and metabolism on later health cannot be predicted with profiling of the cord blood metabolome.

  1. T1 weighted Brain Images at 7 Tesla Unbiased for Proton Density, T2* contrast and RF Coil Receive B1 Sensitivity with Simultaneous Vessel Visualization

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J.; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-01-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique

  2. Are T2-weighted images necessary in renal mass characterization?

    International Nuclear Information System (INIS)

    Dann, Phoebe; Thakur, Ravi; Chin, Deanne; Krinsky, Glenn; Israel, Gary M.

    2006-01-01

    Objective: To determine what role T2-weighted images play in characterizing renal masses. Methods: Forty-four pathologically proven renal masses (34 renal cell carcinomas, 8 oncocytomas, 1 metanephric adenoma, 1 angiomyolipoma without macroscopic fat) and 38 simple renal cysts were evaluated with T1- and T2-weighted images at 1.5 T. Two independent and blinded readers initially characterized all masses using only the T1-weighed images (in- and opposed-phase chemical shift, unenhanced frequency-selective fat-suppressed, gadolinium-enhanced frequency-selective fat-suppressed and subtraction images) and placed each mass into one of three categories: nonsurgical, in need of follow-up, or surgical. The masses were then re-evaluated with the addition of the T2-weighted images. It was determined if the T2-weighted images changed the initial classification. Results: Forty-three of the 44 (98%) pathologically proven renal masses were characterized as a surgical mass using only the T1-weighted images. The remaining renal mass (a renal cell carcinoma) was characterized as a mass in which follow-up exams would be suggested. Thirty-eight of 38 (100%) simple renal cysts were correctly characterized using only the T1-weighted images. The T2-weighted images did not change the initial interpretation of the T1-weighted images in any of the cases. Conclusion: The results of this study suggest that T2-weighted images are not necessary in the evaluation of all renal masses and are specifically not necessary in the differentiation of solid and cystic renal neoplasms from simple renal cysts

  3. 3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle

    International Nuclear Information System (INIS)

    Lim, Chung Hwang; Bae, Sung Jin

    2009-01-01

    This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). T1-weighted images of the cerebrum of brain were obtained from 50 degrees to 130 degrees FA with 10 interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp (-TR/T1) and Ernst angle cos = exp ((-TR/T1). The SNR of WM at 130 degrees FA is approximately 1.6 times higher than the SNR of WM at 50 degrees. The SNR of GM at 130 degrees FA is approximately 1.9 times higher than the SNR of GM at 50 degrees. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120 degrees FA, the SNR of GM started decreasing at less than 110 degrees. The highest SNRs of WM and GM were obtained at 130 degrees FA. The highest CNRs, however, were obtained at 80 degrees FA. Although SNR increased with the change of FA values from 50 degrees to 130 degrees at 3T SE T1WI, CNR was higher at 80 degrees FA than at the usually used 90 degrees FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  4. Dark chocolate and reduced snack consumption in mildly hypertensive adults: an intervention study.

    Science.gov (United States)

    Koli, Raika; Köhler, Klaus; Tonteri, Elina; Peltonen, Juha; Tikkanen, Heikki; Fogelholm, Mikael

    2015-08-22

    Several studies have shown that cocoa and cocoa-containing foods have the potential to lower blood pressure and improve endothelial function. Most of the studies reporting the beneficial effects of dark chocolate on blood pressure have been short (≤ 4 weeks). The aim of the present 8-wks (weeks) study was to assess the effects of regular consumption of dark chocolate during a reduced snack consumption intervention on blood pressure and other cardiovascular risk factors in mildly hypertensive individuals. This was a randomized, controlled, cross-over trial involving 22 adults (8 women, 14 men), aged 33-64 y, BMI 27.7 ± 3.7 kg/m(2) with mild hypertension. During the intervention period (8-wks) the participants reduced the intake of habitual snacks and replaced them with dark chocolate (49 g/day). In the control period, they only reduced the snacks without any added chocolate. Data (blood lipid profile, glucose, insulin, 24 h blood pressure) was collected in the beginning and end of both periods (intervention and control), and some variables also in the run-in and run-out periods (weight, body fat percentage, blood pressure, arterial stiffness index, diet and physical activity). Daily consumption of dark chocolate had no effects on 24 h blood pressure, resting blood pressure (mean ± SD, pre 142 ± 11.5/89 ± 8.4 mmHg vs. post 142 ± 14.2/88 ± 9.4 mmHg in systolic and diastolic blood pressure, respectively) or arterial stiffness (mean ± SD, pre 7.68 ± 0.88 vs. post 7.76 ± 0.89). Weight was reduced by 1.0 ± 2.2 kg during the control (reduced snack only) period, but was unchanged while eating chocolate (p < 0.027 between the treatments). The data collected in this study indicates that inclusion of dark chocolate daily in the diet had no significant effects on blood pressure or other cardiovascular risk factors during a reduced snack period. ClinicalTrials.gov identifier NCT02130141.

  5. Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J [Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA (Netherlands)], E-mail: p.vos@rad.umcn.nl

    2010-03-21

    In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.

  6. Toward a unified description of dark energy and dark matter from the abnormally weighting energy hypothesis

    International Nuclear Information System (INIS)

    Fuezfa, A.; Alimi, J.-M.

    2007-01-01

    The abnormally weighting energy hypothesis consists of assuming that the dark sector of cosmology violates the weak equivalence principle (WEP) on cosmological scales, which implies a violation of the strong equivalence principle for ordinary matter. In this paper, dark energy is shown to result from the violation of WEP by pressureless (dark) matter. This allows us to build a new cosmological framework in which general relativity is satisfied at low scales, as WEP violation depends on the ratio of the ordinary matter over dark matter densities, but at large scales, we obtain a general relativity-like theory with a different value of the gravitational coupling. This explanation is formulated in terms of a tensor-scalar theory of gravitation without WEP for which there exists a revisited convergence mechanism toward general relativity. The consequent dark energy mechanism build upon the anomalous gravity of dark matter (i) does not require any violation of the strong energy condition p 2 /3, (ii) offers a natural way out of the coincidence problem thanks to the nonminimal couplings to gravitation, (iii) accounts fairly for supernovae data from various simple couplings and with density parameters very close to the ones of the concordance model ΛCDM, and therefore suggests an explanation to its remarkable adequacy. Finally, (iv) this mechanism ends up in the future with an Einstein-de Sitter expansion regime once the attractor is reached

  7. Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.

    Science.gov (United States)

    Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack

    2017-09-01

    To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2  = 0.96 and P ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Weighted semiconvex spaces of measurable functions

    International Nuclear Information System (INIS)

    Olaleru, J.O.

    2001-12-01

    Semiconvex spaces are intermediates between locally convex spaces and the non locally convex topological vector spaces. They include all locally convex spaces; hence it is a generalization of locally convex spaces. In this article, we make a study of weighted semiconvex spaces parallel to weighted locally convex spaces where continuous functions are replaced with measurable functions and N p family replaces Nachbin family on a locally compact space X. Among others, we examine the Hausdorffness, completeness, inductive limits, barrelledness and countably barrelledness of weighted semiconvex spaces. New results are obtained while we have a more elegant proofs of old results. Furthermore, we get extensions of some of the old results. It is observed that the technique of proving theorems in weighted locally convex spaces can be adapted to that of weighted semicovex spaces of measurable functions in most cases. (author)

  9. Diagnostic accuracy of automatic normalization of CBV in glioma grading using T1- weighted DCE-MRI.

    Science.gov (United States)

    Sahoo, Prativa; Gupta, Rakesh K; Gupta, Pradeep K; Awasthi, Ashish; Pandey, Chandra M; Gupta, Mudit; Patir, Rana; Vaishya, Sandeep; Ahlawat, Sunita; Saha, Indrajit

    2017-12-01

    Aim of this retrospective study was to compare diagnostic accuracy of proposed automatic normalization method to quantify the relative cerebral blood volume (rCBV) with existing contra-lateral region of interest (ROI) based CBV normalization method for glioma grading using T1-weighted dynamic contrast enhanced MRI (DCE-MRI). Sixty patients with histologically confirmed gliomas were included in this study retrospectively. CBV maps were generated using T1-weighted DCE-MRI and are normalized by contralateral ROI based method (rCBV_contra), unaffected white matter (rCBV_WM) and unaffected gray matter (rCBV_GM), the latter two of these were generated automatically. An expert radiologist with >10years of experience in DCE-MRI and a non-expert with one year experience were used independently to measure rCBVs. Cutoff values for glioma grading were decided from ROC analysis. Agreement of histology with rCBV_WM, rCBV_GM and rCBV_contra respectively was studied using Kappa statistics and intra-class correlation coefficient (ICC). The diagnostic accuracy of glioma grading using the measured rCBV_contra by expert radiologist was found to be high (sensitivity=1.00, specificity=0.96, pnormalization method showed same percentage of agreement for both expert and non-expert user. rCBV_WM showed an agreement of 88.33% (kappa=0.76,pnormalization of CBV using the proposed method could provide better diagnostic accuracy compared to the manual contralateral based approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols

    DEFF Research Database (Denmark)

    Tofts, P.S.; Brix, G; Buckley, D.L.

    1999-01-01

    We describe a standard set of quantity names and symbols related to the estimation of kinetic parameters from dynamic contrast-enhanced T(1)-weighted magnetic resonance imaging data, using diffusable agents such as gadopentetate dimeglumine (Gd-DTPA). These include a) the volume transfer constant K......-limited conditions K(trans) equals the blood plasma flow per unit volume of tissue; under permeability-limited conditions K(trans) equals the permeability surface area product per unit volume of tissue. We relate these quantities to previously published work from our groups; our future publications will refer...

  11. Dark chocolate or tomato extract for prehypertension: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Frank Oliver R

    2009-07-01

    Full Text Available Abstract Background Flavanol-rich chocolate and lycopene-rich tomato extract have attracted interest as potential alternative treatment options for hypertension, a known risk factor for cardiovascular morbidity and mortality. Treatment of prehypertension (SBP 120–139/DBP 80–89 mmHg may forestall progression to hypertension. However, there has been only limited research into non-pharmacological treatment options for prehypertension. We investigated the effect of dark chocolate or tomato extract on blood pressure, and their acceptability as an ongoing treatment option in a prehypertensive population. Methods Our trial consisted of two phases: a randomised controlled three-group-parallel trial over 12 weeks (phase 1 followed by a crossover of the two active treatment arms over an additional 12-week period (phase 2. Group 1 received a 50 g daily dose of dark chocolate with 70% cocoa containing 750 mg polyphenols, group 2 were allocated one tomato extract capsule containing 15 mg lycopene per day, and group 3 received one placebo capsule daily over 8 weeks followed by a 4-week washout period. In phase 2 the active treatment groups were crossed over to receive the alternative treatment. Median blood pressure, weight, and abdominal circumference were measured 4-weekly, and other characteristics including physical activity, general health, energy, mood, and acceptability of treatment were assessed by questionnaire at 0, 8 and 20 weeks. We analysed changes over time using a linear mixed model, and one time point differences using Kruskal-Wallis, Fisher's-Exact, or t-tests. Results Thirty-six prehypertensive healthy adult volunteers completed the 6-month trial. Blood pressure changes over time within groups and between groups were not significant and independent of treatment. Weight and other characteristics did not change significantly during the trial. However, a marked difference in acceptability between the two treatment forms (chocolate or

  12. Periodic Spacing of Protocluster Clumps in a Filamentary Infrared Dark Cloud

    Science.gov (United States)

    Jackson, James M.; Finn, S.; Rathborne, J. M.; Simon, R.

    2010-05-01

    The ''Nessie'' nebula is an extremely filamentary infrared dark cloud, with an aspect ratio of over 300:1. HNC 1-0 observations with the Australia Telescope National Facility's Mopra Telescope demonstrate that Nessie is a single, coherent cloud with high densities (n > 105 cm-3). The filamentary cloud contains a number of protocluster clumps with a nearly regular, periodic spacing of 5 pc. Such clumps naturally arise from the ''varicose'' fluid instability of a self-gravitating fluid cylinder. Because of the ubiquitous association between massive clusters and filamentary molecular clouds (e.g., Orion, NGC 6334, etc.), we speculate that clusters naturally arise from filamentary infrared dark clouds via fluid instabilities.

  13. Bilateral Pulvinar Signal Intensity Decrease on T2-Weighted Images in Patients with Aspartylglucosaminuria

    International Nuclear Information System (INIS)

    Autti, T.; Loennqvist, T.; Joensuu, R.

    2008-01-01

    Background: Aspartylglucosaminuria (AGU) is an autosomal recessive lysosomal disease caused by deficiency of aspartylglucosaminidase. A thalamic T2 signal intensity decrease is associated with lysosomal diseases. Purpose: To investigate thalamic signal intensity in AGU by performing a retrospective review of brain magnetic resonance (MR) imaging studies of AGU patients. Material and Methods: A total of 25 MR examinations were available for 11 patients aged between 3 and 32 years (four patients underwent bone marrow transplantation). Of these, 13 examinations were performed after bone marrow transplantation. Five patients had from two to six examinations, and six patients had one examination each. In every patient, the diagnosis of AGU was confirmed by blood and urine tests. Eighteen examinations were performed with a 1.0T imager including dual spin-echo T2 and proton density (PD) axial and coronal images, and 10 examinations also included T1-weighted images. Seven examinations were performed with a 1.5T imager including turbo spin-echo axial and coronal T2-weighted images and axial fluid-attenuated inversion recovery (FLAIR) images; three examinations included T1-weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo (3D MPRAGE) images. The signal intensity of the thalamus and pulvinar in every sequence was compared to that of the putamina. Results: In AGU, thalamic alterations were first detectable on T2-weighted images (25 examinations in 11 patients) from the age of 3 years 6 months, showing decreased signal intensity in 21 of 24 examinations. T1-weighted images (13 examinations) showed slightly increased thalamic signal intensity in five out of seven examinations from the age of 7 years, and PD images (19 examinations) showed decreased signal intensity from the age of 16 years (three examinations). The pulvinar showed decreased signal intensity on spin-echo T2-weighted images for 14 of 18 examinations or on FLAIR sequences for seven

  14. Optimisation of T{sub 2}{sup *}-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Jennifer Elizabeth, E-mail: jennifer.dixon@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom); Simpson, Ashley, E-mail: ashley.simpson@nhs.net [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Mistry, Niraj, E-mail: niraj.mistry@nottingham.ac.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Evangelou, Nikos, E-mail: nikos.evangelou@nuh.nhs.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Morris, Peter Gordon, E-mail: peter.morris@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom)

    2013-05-15

    T{sub 2}{sup *}-weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T{sub 2}{sup *}-weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions.

  15. Outcome analysis of hemoglobin A1c, weight, and blood pressure in a VA diabetes education program.

    Science.gov (United States)

    North, Susan L; Palmer, Glen A

    2015-01-01

    To determine the effect of a specific diabetes education class (Basics) on hemoglobin A1c values, weight, and systolic blood pressure. In this retrospective study, the researchers compared 2 groups of male veterans with a recent diagnosis of type 2 diabetes. One group received diabetes group education (n = 175) over a 4-month period, and the other received standard diabetes management follow-up (n = 184). Outpatient clinic setting in the Midwest. Basics class compared with standard level of care. Pre- and post-laboratory values for hemoglobin A1c, weight, and systolic blood pressure. Multivariate analysis of covariance and follow-up univariate statistics for significant differences. Findings revealed significant differences in hemoglobin A1c (P education curriculum and reduction of hemoglobin A1c values. Some participants also had added benefit of significant weight loss. Published by Elsevier Inc.

  16. Dark U (1)

    International Nuclear Information System (INIS)

    Chang, Chia-Feng; Ma, Ernest; Yuan, Tzu-Chiang

    2015-01-01

    In this talk we will explore the possibility of adding a local U(1) dark sector to the standard model with the Higgs boson as a portal connecting the visible standard model sector and the dark one. We will discuss existing experimental constraint on the model parameters from the invisible width of Higgs decay. Implications of such a dark U(1) sector on phenomenology at the Large Hardon Collider will be addressed. In particular, detailed results for the non-standard signals of multi-lepton-jets that arise from this simple dark sector will be presented. (paper)

  17. "Smart" theranostic lanthanide nanoprobes with simultaneous up-conversion fluorescence and tunable T1-T2 magnetic resonance imaging contrast and near-infrared activated photodynamic therapy.

    Science.gov (United States)

    Zhang, Yan; Das, Gautom Kumar; Vijayaragavan, Vimalan; Xu, Qing Chi; Padmanabhan, Parasuraman; Bhakoo, Kishore K; Selvan, Subramanian Tamil; Tan, Timothy Thatt Yang

    2014-11-07

    The current work reports a type of "smart" lanthanide-based theranostic nanoprobe, NaDyF4:Yb(3+)/NaGdF4:Yb(3+),Er(3+), which is able to circumvent the up-converting poisoning effect of Dy(3+) ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent.

  18. The bias of weighted dark matter halos from peak theory

    CERN Document Server

    Verde, Licia; Simpson, Fergus; Alvarez-Gaume, Luis; Heavens, Alan; Matarrese, Sabino

    2014-01-01

    We give an analytical form for the weighted correlation function of peaks in a Gaussian random field. In a cosmological context, this approach strictly describes the formation bias and is the main result here. Nevertheless, we show its validity and applicability to the evolved cosmological density field and halo field, using Gaussian random field realisations and dark matter N-body numerical simulations. Using this result from peak theory we compute the bias of peaks (and dark matter halos) and show that it reproduces results from the simulations at the ${\\mathcal O}(10\\%)$ level. Our analytical formula for the bias predicts a scale-dependent bias with two characteristics: a broad band shape which, however, is most affected by the choice of weighting scheme and evolution bias, and a more robust, narrow feature localised at the BAO scale, an effect that is confirmed in simulations. This scale-dependent bias smooths the BAO feature but, conveniently, does not move it. We provide a simple analytic formula to des...

  19. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    International Nuclear Information System (INIS)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon

    1997-01-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change

  20. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon [Hanyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change.

  1. A method for quantifying intervertebral disc signal intensity on T2-weighted imaging

    International Nuclear Information System (INIS)

    Nagashima, Masaki; Abe, Hitoshi; Amaya, Kenji; Matsumoto, Hideo; Yanaihara, Hisashi; Nishiwaki, Yuji; Toyama, Yoshiaki; Matsumoto, Morio

    2012-01-01

    Background Quantification of intervertebral disc degeneration based on intensity of the nucleus pulposus in magnetic resonance imaging (MRI) often uses the mean intensity of the region of interest (ROI) within the nucleus pulposus. However, the location and size of ROI have varied in different reports, and none of the reported methods can be considered fully objective. Purpose To develop a more objective method of establishing ROIs for quantitative evaluation of signal intensity in the nucleus pulposus using T2-weighted MRI. Material and Methods A 1.5-T scanner was used to obtain T2-weighted mid-sagittal images. A total of 288 intervertebral discs from 48 patients (25 men, 23 women) were analyzed. Mean age was 47.4 years (range, 17-69 years). All discs were classified into five grades according to Pfirrmann et al. Discs in grades I and II were defined as bright discs, and discs in grades IV and V were defined as dark discs. Eight candidate methods of ROI determination were devised. The method offering the highest degree of discrimination between bright and dark discs was investigated among these eight methods. Results The method with the greatest degree of discrimination was as follows. The quadrangle formed by anterior and posterior edges of the upper and lower end plates in contact with the intervertebral disc to be measured was defined as the intervertebral area. A shape similar to the intervertebral area but with one-quarter the area was drawn. The geometrical center of the shape was matched to the center of intensity, and this shape was then used as the ROI. Satisfactory validity and reproducibility were obtained using this method. Conclusion The present method offers adequate discrimination and could be useful for longitudinal tracking of intervertebral disc degeneration with sufficient reproducibility

  2. A method for quantifying intervertebral disc signal intensity on T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nagashima, Masaki [Dept. of Orthopaedic Surgery, Keio Univ. School of Medicine, Tokyo (Japan); Dept. of Orthopaedic Surgery, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan); Abe, Hitoshi [Dept. of Orthopaedic Surgery, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan)], E-mail: hit-abe@insti.kitasato-u.ac.jp; Amaya, Kenji [Graduate School of Information Science and Engineering, Tokyo Inst. of Technology, Tokyo (Japan); Matsumoto, Hideo [Inst. for Integrated Sports Medicine, Keio Univ. School of Medicine, Tokyo (Japan); Yanaihara, Hisashi [Dept. of Diagnostic Radiology, Kitasato Univ. Kitasato Inst. Hospital, Tokyo (Japan); Nishiwaki, Yuji [Dept. of Environmental and Occupational Health, Toho Univ. School of Medicine, Tokyo (Japan); Toyama, Yoshiaki; Matsumoto, Morio [Dept. of Orthopaedic Surgery, Keio Univ. School of Medicine, Tokyo (Japan)

    2012-11-15

    Background Quantification of intervertebral disc degeneration based on intensity of the nucleus pulposus in magnetic resonance imaging (MRI) often uses the mean intensity of the region of interest (ROI) within the nucleus pulposus. However, the location and size of ROI have varied in different reports, and none of the reported methods can be considered fully objective. Purpose To develop a more objective method of establishing ROIs for quantitative evaluation of signal intensity in the nucleus pulposus using T2-weighted MRI. Material and Methods A 1.5-T scanner was used to obtain T2-weighted mid-sagittal images. A total of 288 intervertebral discs from 48 patients (25 men, 23 women) were analyzed. Mean age was 47.4 years (range, 17-69 years). All discs were classified into five grades according to Pfirrmann et al. Discs in grades I and II were defined as bright discs, and discs in grades IV and V were defined as dark discs. Eight candidate methods of ROI determination were devised. The method offering the highest degree of discrimination between bright and dark discs was investigated among these eight methods. Results The method with the greatest degree of discrimination was as follows. The quadrangle formed by anterior and posterior edges of the upper and lower end plates in contact with the intervertebral disc to be measured was defined as the intervertebral area. A shape similar to the intervertebral area but with one-quarter the area was drawn. The geometrical center of the shape was matched to the center of intensity, and this shape was then used as the ROI. Satisfactory validity and reproducibility were obtained using this method. Conclusion The present method offers adequate discrimination and could be useful for longitudinal tracking of intervertebral disc degeneration with sufficient reproducibility.

  3. The local dark matter phase-space density and impact on WIMP direct detection

    International Nuclear Information System (INIS)

    Catena, Riccardo; Ullio, Piero

    2012-01-01

    We present a new determination of the local dark matter phase-space density. This result is obtained implementing, in the limit of isotropic velocity distribution and spherical symmetry, Eddington's inversion formula, which links univocally the dark matter distribution function to the density profile, and applying, within a Bayesian framework, a Markov Chain Monte Carlo algorithm to sample mass models for the Milky Way against a broad and variegated sample of dynamical constraints. We consider three possible choices for the dark matter density profile, namely the Einasto, NFW and Burkert profiles, finding that the velocity dispersion, which characterizes the width in the distribution, tends to be larger for the Burkert case, while the escape velocity depends very weakly on the profile, with the mean value we obtain being in very good agreement with estimates from stellar kinematics. The derived dark matter phase-space densities differ significantly — most dramatically in the high velocity tails — from the model usually taken as a reference in dark matter detection studies, a Maxwell-Boltzmann distribution with velocity dispersion fixed in terms of the local circular velocity and with a sharp truncation at a given value of the escape velocity. We discuss the impact of astrophysical uncertainties on dark matter scattering rates and direct detection exclusion limits, considering a few sample cases and showing that the most sensitive ones are those for light dark matter particles and for particles scattering inelastically. As a general trend, regardless of the assumed profile, when adopting a self-consistent phase-space density, we find that rates are larger, and hence exclusion limits stronger, than with the standard Maxwell-Boltzmann approximation. Tools for applying our result on the local dark matter phase-space density to other dark matter candidates or experimental setups are provided

  4. Mixed dark matter in left-right symmetric models

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, Asher [Department of Physics, University of Chicago,Chicago, Illinois 60637 (United States); Fox, Patrick J. [Theoretical Physics Department, Fermilab,Batavia, Illinois 60510 (United States); Hooper, Dan [Center for Particle Astrophysics, Fermi National Accelerator Laboratory,Batavia, Illinois 60510 (United States); Department of Astronomy and Astrophysics, University of Chicago,Chicago, Illinois 60637 (United States); Mohlabeng, Gopolang [Center for Particle Astrophysics, Fermi National Accelerator Laboratory,Batavia, Illinois 60510 (United States); Department of Physics and Astronomy, University of Kansas,Lawrence, Kansas 66045 (United States)

    2016-06-08

    Motivated by the recently reported diboson and dijet excesses in Run 1 data at ATLAS and CMS, we explore models of mixed dark matter in left-right symmetric theories. In this study, we calculate the relic abundance and the elastic scattering cross section with nuclei for a number of dark matter candidates that appear within the fermionic multiplets of left-right symmetric models. In contrast to the case of pure multiplets, WIMP-nucleon scattering proceeds at tree-level, and hence the projected reach of future direct detection experiments such as LUX-ZEPLIN and XENON1T will cover large regions of parameter space for TeV-scale thermal dark matter. Decays of the heavy charged W{sup ′} boson to particles in the dark sector can potentially shift the right-handed gauge coupling to larger values when fixed to the rate of the Run 1 excesses, moving towards the theoretically attractive scenario, g{sub R}=g{sub L}. This region of parameter space may be probed by future collider searches for new Higgs bosons or electroweak fermions.

  5. Tuning the non-covalent confinement of Gd(III) complexes in silica nanoparticles for high T1-weighted MR imaging capability.

    Science.gov (United States)

    Fedorenko, Svetlana V; Grechkina, Svetlana L; Mustafina, Asiya R; Kholin, Kirill V; Stepanov, Alexey S; Nizameev, Irek R; Ismaev, Ildus E; Kadirov, Marsil K; Zairov, Rustem R; Fattakhova, Alfia N; Amirov, Rustem R; Soloveva, Svetlana E

    2017-01-01

    The present work introduces deliberate synthesis of Gd(III)-doped silica nanoparticles with high relaxivity at magnetic field strengths below 1.5T. Modified microemulsion water-in-oil procedure was used in order to achieve superficial localization of Gd(III) complexes within 40-55nm sized silica spheres. The relaxivities of the prepared nanoparticles were measured at 0.47, 1.41 and 1.5T with the use of both NMR analyzer and whole body NMR scanner. Longitudinal relaxivities of the obtained silica nanoparticles reveal significant dependence on the confinement mode, changing from 4.1 to 49.6mM -1 s -1 at 0.47T when the localization of Gd(III) complexes changes from core to superficial zones of the silica spheres. The results highlight predominant contribution of the complexes located close to silica/water interface to the relaxivity of the nanoparticles. Low effect of blood proteins on the relaxivity in the aqueous colloids of the nanoparticles was exemplified by serum bovine albumin. T 1 - weighted MRI data indicate that the nanoparticles provide strong positive contrast at 1.5T, which along with low cytotoxicity effect make a good basis for their application as contrast agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. An age estimation method using brain local features for T1-weighted images.

    Science.gov (United States)

    Kondo, Chihiro; Ito, Koichi; Kai Wu; Sato, Kazunori; Taki, Yasuyuki; Fukuda, Hiroshi; Aoki, Takafumi

    2015-08-01

    Previous statistical analysis studies using large-scale brain magnetic resonance (MR) image databases have examined that brain tissues have age-related morphological changes. This fact indicates that one can estimate the age of a subject from his/her brain MR image by evaluating morphological changes with healthy aging. This paper proposes an age estimation method using local features extracted from T1-weighted MR images. The brain local features are defined by volumes of brain tissues parcellated into local regions defined by the automated anatomical labeling atlas. The proposed method selects optimal local regions to improve the performance of age estimation. We evaluate performance of the proposed method using 1,146 T1-weighted images from a Japanese MR image database. We also discuss the medical implication of selected optimal local regions.

  7. [A cohort study on the correlation between birth weight, simple obesity, blood lipids, blood glucose and blood pressure from childhood to adolescence].

    Science.gov (United States)

    Hua, Qi; Tan, Jing; Liu, Zhao-hui; Liu, Rong-kun; Yang, Zheng

    2007-11-01

    To determine the correlation between birth weight and simple obesity, blood lipids, blood glucose and blood pressure from childhood to adolescence. A vertical sectional survey on 193 children aged 7 - 11 years was performed in 1996. A questionnaire consisting of items on environmental factors and lifestyle, physical examination and biochemical assessment was conducted at baseline and the 9th year of follow-up. The incidence of obesity and over-weight in childhood in high (6.1%) and low birth-weight group (5.6%) was higher than that in normal birth-weight group (2.8%), but did not reach statistic significance; The levels of body mass index in adolescence in high and low birth-weight group were significantly higher than that in normal birth-weight group (P = 0.002 and 0.009, respectively), and the incidence of obesity and over-weight in adolescence was significantly higher in high (33.3%) and low birth-weight group (38.9%) than that in normal birth-weight group (16.2%, P = 0.025 and 0.020, respectively). There were no significant differences in the levels of blood glucose, blood lipids and blood pressure between different birth weight groups (all, P > 0.05). Intrauterine growth is linked to physical growth during childhood and adolescence. Nutritional guidance in pregnant phase may help to control the increased prevalence of overweight and obesity in children and adolescent.

  8. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    Science.gov (United States)

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (Pspot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  9. Top-philic dark matter within and beyond the WIMP paradigm

    Science.gov (United States)

    Garny, Mathias; Heisig, Jan; Hufnagel, Marco; Lülf, Benedikt

    2018-04-01

    We present a comprehensive analysis of top-philic Majorana dark matter that interacts via a colored t -channel mediator. Despite the simplicity of the model—introducing three parameters only—it provides an extremely rich phenomenology allowing us to accommodate the relic density for a large range of coupling strengths spanning over 6 orders of magnitude. This model features all "exceptional" mechanisms for dark matter freeze-out, including the recently discovered conversion-driven freeze-out mode, with interesting signatures of long-lived colored particles at colliders. We constrain the cosmologically allowed parameter space with current experimental limits from direct, indirect and collider searches, with special emphasis on light dark matter below the top mass. In particular, we explore the interplay between limits from Xenon1T, Fermi-LAT and AMS-02 as well as limits from stop, monojet and Higgs invisible decay searches at the LHC. We find that several blind spots for light dark matter evade current constraints. The region in parameter space where the relic density is set by the mechanism of conversion-driven freeze-out can be conclusively tested by R -hadron searches at the LHC with 300 fb-1 .

  10. Diagnostic value of brain chronic black holes on T1-weighted MR images in clinically isolated syndromes.

    Science.gov (United States)

    Mitjana, Raquel; Tintoré, Mar; Rocca, Maria A; Auger, Cristina; Barkhof, Frederik; Filippi, Massimo; Polman, Chris; Fazekas, Franz; Huerga, Elena; Montalban, Xavier; Rovira, Alex

    2014-10-01

    Non-enhancing black holes (neBHs) are more common in multiple sclerosis (MS) patients with longer disease durations and progressive disease subtypes. Our aim was to analyse the added value of neBHs in patients with clinically isolated syndromes (CISs) for predicting conversion to clinically definite MS (CDMS). Patients were classified based on the presence or absence of neBHs and on the number of Barkhof-Tintoré (B-T) criteria fulfilled. Dissemination in space (DIS) was defined as the presence of at least three of the four B-T criteria. Dissemination in time (DIT)1 was defined by simultaneous presence of enhancing and non-enhancing lesions. DIT2 was defined by simultaneous presence of neBHs and T2 lesions not apparent on T1-weighted images. Focal T2-hyperintense brain lesions were identified in 87.7% of the 520 CIS patients, and 41.4% of them presented at least one neBH. Patients meeting DIS, DIT1, and DIT2 had a significantly higher rate of conversion to CDMS. After adjusting for DIS, only patients who fulfilled DIT1 preserved a significant increase in CDMS conversion. Non-enhancing black holes in CIS patients are associated with a higher risk of conversion to CDMS. However, the predictive value of this finding is lost when added to the DIS criteria. © The Author(s) 2014.

  11. Energy weighted x-ray dark-field imaging.

    Science.gov (United States)

    Pelzer, Georg; Zang, Andrea; Anton, Gisela; Bayer, Florian; Horn, Florian; Kraus, Manuel; Rieger, Jens; Ritter, Andre; Wandner, Johannes; Weber, Thomas; Fauler, Alex; Fiederle, Michael; Wong, Winnie S; Campbell, Michael; Meiser, Jan; Meyer, Pascal; Mohr, Jürgen; Michel, Thilo

    2014-10-06

    The dark-field image obtained in grating-based x-ray phase-contrast imaging can provide information about the objects' microstructures on a scale smaller than the pixel size even with low geometric magnification. In this publication we demonstrate that the dark-field image quality can be enhanced with an energy-resolving pixel detector. Energy-resolved x-ray dark-field images were acquired with a 16-energy-channel photon-counting pixel detector with a 1 mm thick CdTe sensor in a Talbot-Lau x-ray interferometer. A method for contrast-noise-ratio (CNR) enhancement is proposed and validated experimentally. In measurements, a CNR improvement by a factor of 1.14 was obtained. This is equivalent to a possible radiation dose reduction of 23%.

  12. Bundles over Quantum RealWeighted Projective Spaces

    Directory of Open Access Journals (Sweden)

    Tomasz Brzeziński

    2012-09-01

    Full Text Available The algebraic approach to bundles in non-commutative geometry and the definition of quantum real weighted projective spaces are reviewed. Principal U(1-bundles over quantum real weighted projective spaces are constructed. As the spaces in question fall into two separate classes, the negative or odd class that generalises quantum real projective planes and the positive or even class that generalises the quantum disc, so do the constructed principal bundles. In the negative case the principal bundle is proven to be non-trivial and associated projective modules are described. In the positive case the principal bundles turn out to be trivial, and so all the associated modules are free. It is also shown that the circle (coactions on the quantum Seifert manifold that define quantum real weighted projective spaces are almost free.

  13. Flavonoid-rich dark chocolate improves endothelial function and increases plasma epicatechin concentrations in healthy adults.

    Science.gov (United States)

    Engler, Mary B; Engler, Marguerite M; Chen, Chung Y; Malloy, Mary J; Browne, Amanda; Chiu, Elisa Y; Kwak, Ho-Kyung; Milbury, Paul; Paul, Steven M; Blumberg, Jeffrey; Mietus-Snyder, Michele L

    2004-06-01

    Dark chocolate derived from the plant (Theobroma cacao) is a rich source of flavonoids. Cardioprotective effects including antioxidant properties, inhibition of platelet activity, and activation of endothelial nitric oxide synthase have been ascribed to the cocoa flavonoids. To investigate the effects of flavonoid-rich dark chocolate on endothelial function, measures of oxidative stress, blood lipids, and blood pressure in healthy adult subjects. The study was a randomized, double-blind, placebo-controlled design conducted over a 2 week period in 21 healthy adult subjects. Subjects were randomly assigned to daily intake of high-flavonoid (213 mg procyanidins, 46 mg epicatechin) or low-flavonoid dark chocolate bars (46 g, 1.6 oz). High-flavonoid chocolate consumption improved endothelium-dependent flow-mediated dilation (FMD) of the brachial artery (mean change = 1.3 +/- 0.7%) as compared to low-flavonoid chocolate consumption (mean change = -0.96 +/- 0.5%) (p = 0.024). No significant differences were noted in the resistance to LDL oxidation, total antioxidant capacity, 8-isoprostanes, blood pressure, lipid parameters, body weight or body mass index (BMI) between the two groups. Plasma epicatechin concentrations were markedly increased at 2 weeks in the high-flavonoid group (204.4 +/- 18.5 nmol/L, p < or = 0.001) but not in the low-flavonoid group (17.5 +/- 9 nmol/L, p = 0.99). Flavonoid-rich dark chocolate improves endothelial function and is associated with an increase in plasma epicatechin concentrations in healthy adults. No changes in oxidative stress measures, lipid profiles, blood pressure, body weight or BMI were seen.

  14. Robust T1-weighted structural brain imaging and morphometry at 7T using MP2RAGE.

    Directory of Open Access Journals (Sweden)

    Kieran R O'Brien

    Full Text Available PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0 ± 4.1 years; 6 Male, who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004. In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004 from an average volumetric difference across structures of ≈ 6.6% to ≈ 2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.

  15. Dark matter and halo bispectrum in redshift space: theory and applications

    Energy Technology Data Exchange (ETDEWEB)

    Gil-Marín, Héctor; Percival, Will [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Portsmouth PO1 3FX (United Kingdom); Wagner, Christian [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild Str. 1, 85741 Garching (Germany); Noreña, Jorge [Department of Theoretical Physics and Center for Astroparticle Physics (CAP), 24 quai E. Ansermet, CH-1211 Geneva 4 (Switzerland); Verde, Licia, E-mail: hector.gil@port.ac.uk, E-mail: cwagner@mpa-garching.mpg.de, E-mail: jorge.norena@unige.ch, E-mail: liciaverde@icc.ub.edu, E-mail: will.percival@port.ac.uk [ICREA Institució Catalana de Recerca i Estudis Avançats, Passeig Lluís Companys 23, E-08010 Barcelona (Spain)

    2014-12-01

    We present a phenomenological modification of the standard perturbation theory prediction for the bispectrum in redshift space that allows us to extend the model to mildly non-linear scales over a wide range of redshifts, z≤1.5. Our model require 18 free parameters that are fitted to N-body simulations using the shapes k{sub 2}/k{sub 1}=11.5, 2.0, 2.5. We find that we can describe the bispectrum of dark matter particles with ∼5% accuracy for k{sub i}∼<0.10 h/Mpc at z=0, for k{sub i}∼<0.15 h/Mpc at z=0.5, for k{sub i}∼<0.17 h/Mpc at z=1.0 and for k{sub i}∼<0.20 h/Mpc at z=1.5. For very squeezed triangles with k{sub 1}=k{sub 2}∼>0.1 hMpc{sup -1} and k{sub 3}≤0.02 hMpc{sup -1}, however, neither SPT nor the proposed fitting formula are able to describe the measured dark matter bispectrum with this accuracy. We show that the fitting formula is sufficiently general that can be applied to other intermediate shapes such as k{sub 2}/k{sub 1}=1.25, 1.75, and 2.25. We also test that the fitting formula is able to describe with similar accuracy the bispectrum of cosmologies with different Ω{sub m}, in the range 0.2∼< Ω{sub m} ∼< 0.4, and consequently with different values of the logarithmic grow rate f at z=0, 0.4∼< f(z=0) ∼< 0.6. We apply this new formula to recover the bias parameters, f and σ{sub 8}, by combining the redshift space power spectrum monopole and quadrupole with the bispectrum monopole for both dark matter particles and haloes. We find that the combination of these three statistics can break the degeneracy between b{sub 1}, f and σ{sub 8}. For dark matter particles the new model can be used to recover f and σ{sub 8} with ∼1% accuracy. For dark matter haloes we find that f and σ{sub 8} present larger systematic shifts, ∼10%. The systematic offsets arise because of limitations in the modelling of the interplay between bias and redshift space distortions, and represent a limitation as the statistical errors of

  16. Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences

    International Nuclear Information System (INIS)

    Kwon, J.W.; Yoon, Y.C.; Choi, S.-H.

    2012-01-01

    Aim: To compare three-dimensional (3D) isotropic T2-weighted magnetic resonance imaging (MRI) sequences and reformation with two-dimensional (2D) T2-weighted sequences regarding image quality of the cervical spine at 3 T. Materials and methods: A phantom study was performed using a water-filled cylinder. The signal-to-noise and image homogeneity were evaluated. Fourteen (n = 14) volunteers were examined at 3 T using 3D isotropic T2-weighted sagittal and conventional 2D T2-weighted sagittal, axial, and oblique sagittal MRI. Multiplanar reformation (MPR) of the 3D T2-weighted sagittal dataset was performed simultaneously with image evaluation. In addition to artefact assessment, the visibility of anatomical structures in the 3D and 2D sequences was qualitatively assessed by two radiologists independently. Cohen’s kappa and Wilcoxon signed rank test were used for the statistical analysis. Result: The 3D isotropic T2-weighted sequence resulted in the highest signal-to-noise ratio (SNR) and lowest non-uniformity (NU) among the sequences in the phantom study. Quantitative evaluation revealed lower NU values of the cerebrospinal fluid (CSF) and muscles in 2D T2-weighted sagittal sequences compared to the 3D volume isotropic turbo spin-echo acquisition (VISTA) sequence. The other NU values revealed no statistically significant difference between the 2D turbo spin-echo (TSE) and 3D VISTA sequences (0.059 < p < 0.959). 3D VISTA images showed significantly fewer CSF flow artefacts (p < 0.001) and better delineated intradural nerve rootlets (p = 0.001) and neural foramina (p = 0.016) compared to 2D sequences. Conclusion: A 3D T2 weighted sequence is superior to conventional 2D sequences for the delineation of intradural nerve rootlets and neural foramina and is less affected by CSF flow artefacts.

  17. Fermionic dark matter in a simple t-channel model

    International Nuclear Information System (INIS)

    Goyal, Ashok; Kumar, Mukesh

    2016-01-01

    We consider a fermionic dark matter (DM) particle in renormalizable Standard Model (SM) gauge interactions in a simple t-channel model. The DM particle interactions with SM fermions is through the exchange of scalar and vector mediators which carry colour or lepton number. In the case of coloured mediators considered in this study, we find that if the DM is thermally produced and accounts for the observed relic density almost the entire parameter space is ruled out by the direct detection observations. The bounds from the monojet plus missing energy searches at the Large Hadron Collider are less stringent in this case. In contrast for the case of Majorana DM, we obtain strong bounds from the monojet searches which rule out DM particles of mass less than about a few hundred GeV for both the scalar and vector mediators.

  18. Dynamical 3-Space: Alternative Explanation of the "Dark Matter Ring"

    Directory of Open Access Journals (Sweden)

    Cahill R. T.

    2007-10-01

    Full Text Available NASA has claimed the discovery of a “Ring of Dark Matter” in the galaxy cluster CL 0024 +17, see Jee M.J. et al. arXiv:0705.2171, based upon gravitational lensing data. Here we show that the lensing can be given an alternative explanation that does not involve “dark matter”. This explanation comes from the new dynamics of 3-space. This dynamics involves two constant G and alpha — the fine structure constant. This dynamics has explained the bore hole anomaly, spiral galaxy flat rotation speeds, the masses of black holes in spherical galaxies, gravitational light bending and lensing, all without invoking “dark matter”, and also the supernova redshift data without the need for “dark energy”.

  19. Association between blood cholesterol and sodium intake in hypertensive women with excess weight.

    Science.gov (United States)

    Padilha, Bruna Merten; Ferreira, Raphaela Costa; Bueno, Nassib Bezerra; Tassitano, Rafael Miranda; Holanda, Lidiana de Souza; Vasconcelos, Sandra Mary Lima; Cabral, Poliana Coelho

    2018-04-01

    Restricted sodium intake has been recommended for more than 1 century for the treatment of hypertension. However, restriction seems to increase blood cholesterol. In women with excess weight, blood cholesterol may increase even more because of insulin resistance and the high lipolytic activity of adipose tissue.The aim of this study was to assess the association between blood cholesterol and sodium intake in hypertensive women with and without excess weight.This was a cross-sectional study with hypertensive and nondiabetic women aged 20 to 59 years, recruited at the primary healthcare units of Maceio, Alagoas, Brazilian Northeast. Excess weight was defined as body mass index (BMI) ≥25.0 kg/m. Sodium intake was estimated by the 24-hour urinary excretion of sodium. Blood cholesterol was the primary outcome investigated by this study, and its relationship with sodium intake and other variables was assessed by Pearson correlation and multivariate linear regression using a significance level of 5%.This study included 165 hypertensive women. Of these, 135 (81.8%) were with excess weight. The mean sodium intake was 3.7 g (±1.9) and 3.4 g (±2.4) in hypertensive women with and without excess weight, respectively. The multiple normal linear regression models fitted to the "blood cholesterol" in the 2 groups reveal that for the group of hypertensive women without excess weight only 1 independent variable "age" is statistically significant to explain the variability of the blood cholesterol levels. However, for the group of hypertensive women with excess weight, 2 independent variables, age and sodium intake, can statistically explain variations of the blood cholesterol levels.Blood cholesterol is statistically inversely related to sodium intake for hypertensive women with excess weight, but it is not statistically related to sodium intake for hypertensive women without excess weight.

  20. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance–Guided Radiotherapy Treatment Planning

    Science.gov (United States)

    Freedman, Joshua N.; Collins, David J.; Bainbridge, Hannah; Rank, Christopher M.; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O.; Wetscherek, Andreas

    2017-01-01

    Objectives The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Materials and Methods Ten patients with primary non–small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. Results High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all

  1. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    Science.gov (United States)

    Freedman, Joshua N; Collins, David J; Bainbridge, Hannah; Rank, Christopher M; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O; Wetscherek, Andreas

    2017-10-01

    The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all respiratory phases and patients), between

  2. Natural Implementation of Neutralino Dark Matter

    CERN Document Server

    King, S F

    2006-01-01

    The prediction of neutralino dark matter is generally regarded as one of the successes of the Minimal Supersymmetric Standard Model (MSSM). However the successful regions of parameter space allowed by WMAP and collider constraints are quite restricted. We discuss fine-tuning with respect to both dark matter and Electroweak Symmetry Breaking (EWSB) and explore regions of MSSM parameter space with non-universal gaugino and third family scalar masses in which neutralino dark matter may be implemented naturally. In particular allowing non-universal gauginos opens up the bulk region that allows Bino annihilation via t-channel slepton exchange, leading to ``supernatural dark matter'' corresponding to no fine-tuning at all with respect to dark matter. By contrast we find that the recently proposed ``well tempered neutralino'' regions involve substantial fine-tuning of MSSM parameters in order to satisfy the dark matter constraints, although the fine tuning may be ameliorated if several annihilation channels act simu...

  3. Determining dark matter properties with a XENONnT/LZ signal and LHC Run 3 monojet searches

    Science.gov (United States)

    Baum, Sebastian; Catena, Riccardo; Conrad, Jan; Freese, Katherine; Krauss, Martin B.

    2018-04-01

    We develop a method to forecast the outcome of the LHC Run 3 based on the hypothetical detection of O (100 ) signal events at XENONnT. Our method relies on a systematic classification of renormalizable single-mediator models for dark matter-quark interactions and is valid for dark matter candidates of spin less than or equal to one. Applying our method to simulated data, we find that at the end of the LHC Run 3 only two mutually exclusive scenarios would be compatible with the detection of O (100 ) signal events at XENONnT. In the first scenario, the energy distribution of the signal events is featureless, as for canonical spin-independent interactions. In this case, if a monojet signal is detected at the LHC, dark matter must have spin 1 /2 and interact with nucleons through a unique velocity-dependent operator. If a monojet signal is not detected, dark matter interacts with nucleons through canonical spin-independent interactions. In a second scenario, the spectral distribution of the signal events exhibits a bump at nonzero recoil energies. In this second case, a monojet signal can be detected at the LHC Run 3; dark matter must have spin 1 /2 and interact with nucleons through a unique momentum-dependent operator. We therefore conclude that the observation of O (100 ) signal events at XENONnT combined with the detection, or the lack of detection, of a monojet signal at the LHC Run 3 would significantly narrow the range of possible dark matter-nucleon interactions. As we argued above, it can also provide key information on the dark matter particle spin.

  4. Another two dark energy models motivated from Karolyhazy uncertainty relation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Cheng-Yi; Yang, Wen-Li; Song, Yu. [Northwest University, Institute of Modern Physics, Xian (China); Yue, Rui-Hong [Ningbo University, Faculty of Science, Ningbo (China)

    2012-03-15

    The Karolyhazy uncertainty relation indicates that there exists a minimal detectable cell {delta}t{sup 3} over the region t{sup 3} in Minkowski space-time. Due to the energy-time uncertainty relation, the energy of the cell {delta}t {sup 3} cannot be less {delta}t{sup -1}. Then we get a new energy density of metric fluctuations of Minkowski spacetime as {delta}t{sup -4}. Motivated by the energy density, we propose two new dark-energy models. One model is characterized by the age of the universe and the other is characterized by the conformal age of the universe. We find that in the two models, the dark energy mimics a cosmological constant in the late time. (orig.)

  5. Little composite dark matter.

    Science.gov (United States)

    Balkin, Reuven; Perez, Gilad; Weiler, Andreas

    2018-01-01

    We examine the dark matter phenomenology of a composite electroweak singlet state. This singlet belongs to the Goldstone sector of a well-motivated extension of the Littlest Higgs with T -parity. A viable parameter space, consistent with the observed dark matter relic abundance as well as with the various collider, electroweak precision and dark matter direct detection experimental constraints is found for this scenario. T -parity implies a rich LHC phenomenology, which forms an interesting interplay between conventional natural SUSY type of signals involving third generation quarks and missing energy, from stop-like particle production and decay, and composite Higgs type of signals involving third generation quarks associated with Higgs and electroweak gauge boson, from vector-like top-partners production and decay. The composite features of the dark matter phenomenology allows the composite singlet to produce the correct relic abundance while interacting weakly with the Higgs via the usual Higgs portal coupling [Formula: see text], thus evading direct detection.

  6. Ordinary matter, dark matter, and dark energy on normal Zeeman space-times

    Science.gov (United States)

    Imre Szabó, Zoltán

    2017-01-01

    Zeeman space-times are new, relativistic, and operator based Hamiltonian models representing multi-particle systems. They are established on Lorentzian pseudo Riemannian manifolds whose Laplacian immediately appears in the form of original quantum physical wave operators. In classical quantum theory they emerge, differently, from the Hamilton formalism and the correspondence principle. Nonetheless, this new model does not just reiterate the well known conceptions but holds the key to solving open problems of quantum theory. Most remarkably, it represents the dark matter, dark energy, and ordinary matter by the same ratios how they show up in experiments. Another remarkable agreement with reality is that the ordinary matter appears to be non-expanding and is described in consent with observations. The theory also explains gravitation, moreover, the Hamilton operators of all energy and matter formations, together with their physical properties, are solely derived from the Laplacian of the Zeeman space-time. By this reason, it is called Monistic Wave Laplacian which symbolizes an all-comprehensive unification of all matter and energy formations. This paper only outlines the normal case where the particles do not have proper spin but just angular momentum. The complete anomalous theory is detailed in [Sz2, Sz3, Sz4, Sz5, Sz6, Sz7].

  7. Characteristic signal changes in the pontine base on T2- and multishot diffusion-weighted images in spinocerebellar ataxia type 1

    International Nuclear Information System (INIS)

    Adachi, M.; Kawanami, T.; Ohshima, H.; Hosoya, T.

    2006-01-01

    The aim of the present study was to demonstrate characteristic signal changes of the pontine base on T2-weighted images of patients with SCA 1, and to elucidate the relationship between abnormal high-intensities of the pontine base on T2-weighted images and the findings on multishot diffusion-weighted images. We assessed abnormal signals of the pontine base on T2-weighted images from 50 controls and six patients with SCA 1 diagnosed by genetic analysis. At the same time, we evaluated the degeneration of the transverse pontine fibers in the pontine base by multishot diffusion-weighted imaging. A midline high-intensity was seen in the pontine base on T2-weighted images in two of the 50 controls and five of the six patients with SCA 1. The midline high-intensity had a sensitivity of 83.3% for patients and a specificity of 96.0% for controls. Multishot diffusion-weighted imaging demonstrated the degeneration - the amorphous-pattern signal - of the transverse pontine fibers in four (66.7%) of the six patients. In the other two patients, the zebra-pattern signal was seen in the pontine base. The midline high-intensity on T2-weighted images appears to be one of characteristic MRI findings of SCA 1. Multishot diffusion-weighted imaging suggested that the midline high-intensity should reflect the degeneration of the transverse pontine fibers. (orig.)

  8. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  9. Developmental patterns of fetal fat and corresponding signal on T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Blondiaux, Eleonore; Chougar, Lydia; Ducou le Pointe, Hubert; Garel, Catherine; Gelot, Antoinette; Valence, Stephanie; Audureau, Etienne; Jouannic, Jean-Marie; Dhombres, Ferdinand

    2018-01-01

    Evaluation of subcutaneous fetal fat layer thickness on T1-weighted sequences can be used to predict birth weight. Little is known about normal MR signal patterns of subcutaneous tissue throughout pregnancy. To establish developmental patterns of subcutaneous fetal fat signal on T1-weighted sequences during the 2nd and 3rd trimesters. We retrospectively examined T1-weighted images of 110 fetal MRI scans. We measured signal intensity of subcutaneous fat on thighs, buttocks, trunk, nuchal region, chin and scalp. We then calculated the ratios of the obtained values with fetal muscle, amnios and maternal fat signal, and compared the results with those of immunohistochemical examination of adipose tissue extracted from the abdominal wall of fetuses as part of standard autopsy protocol. We included 60 MRI scans in fetuses without intra-uterine growth restriction or macrosomia of non-diabetic mothers (range 23-37 weeks of gestation). Fat T1 intensity of all anatomical regions was low in all fetuses before 26 weeks of gestation. It became more hyperintense with increasing gestational age, in the following order: chin and nuchal region, then buttocks, thighs and trunk, and eventually the scalp at 33 weeks of gestation. After 33 weeks of gestation, all fetal subcutaneous tissues demonstrated overall hyperintense signal. This progression followed the conversion at immunohistochemistry of fetal adipose tissue composition from predominant brown to white adipose cells in 19 fetuses (19-41 weeks of gestation). Between 26 weeks and 33 weeks of gestation, subcutaneous fetal fat signal changed in an orderly pattern from chin to buttocks and scalp. This may reflect the conversion from predominant brown to white adipose tissues in subcutaneous fetal fat. (orig.)

  10. Weight gain is associated with improved glycaemic control but with adverse changes in plasma lipids and blood pressure isn Type 1 diabetes.

    LENUS (Irish Health Repository)

    Ferriss, J B

    2012-02-03

    AIMS: To assess the effects of weight gain on metabolic control, plasma lipids and blood pressure in patients with Type 1 diabetes. METHODS: Patients in the EURODIAB Prospective Complications Study (n = 3250) were examined at baseline and 1800 (55%) were re-examined a mean of 7.3 years later. Patients had Type 1 diabetes, defined as a diagnosis made before age 36 years and with a need for continuous insulin therapy within a year of diagnosis. Patients were aged 15-60 years at baseline and were stratified for age, sex and duration of diabetes. RESULTS: The change in HbA(1c) from baseline to follow-up examination was significantly more favourable in those who gained 5 kg or more during follow-up (\\'marked weight gain\\') than in patients who gained less or no weight or lost weight (\\'less or no weight gain\\'). In those with marked weight gain, there was a significantly greater rise in plasma triglycerides and total cholesterol and significantly less favourable changes in low-density lipoprotein and high-density lipoprotein cholesterol compared with those with less or no weight gain, with or without adjustment for HbA(1c). Systolic and diastolic blood pressure also rose significantly more in the group with marked weight gain. CONCLUSION: Weight gain in patients with Type 1 diabetes has adverse effects on plasma lipids and blood pressure, despite a small improvement in glycaemic control.

  11. Classification of hematopoietic regions in out-of-phase T1-weighted images. A quantitative comparison study with T1-weighted and STIR images

    International Nuclear Information System (INIS)

    Amano, Yasuo; Amano, Maki; Kijima, Tetsuji; Kumazaki, Tatsuo

    1995-01-01

    The hematopoietic regions were classified into two groups on the basis of out-of-phase T 1 -weighted images (op-TlWI): regions with lower intensity than that of muscle (LH) and regions with intensity equal to or higher than that of muscle (HH). We quantitatively evaluated the differences in signal intensity between LH and HH in order to examine this classification. Forty-two hematopoietic areas in aplastic anemia were classified into two groups of 23 LH and 19 HH. The signal ratios of hematopoietic areas to muscle on TlWI and STIR were calculated, and the differences between LH and HH were statistically evaluated. The signal ratios of LH were significantly higher on TlWI and lower on STIR than those of HH (unpaired t-test, p<0.05). This result indicated that LH consisted of more hypocellular marrow than HH. Op-TlWI were useful in differentiating between LH and HH and defining the degree of hematopoiesis in aplastic anemia. (author)

  12. Can tonne-scale direct detection experiments discover nuclear dark matter?

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, Alistair; Kirk, Russell; Monroe, Jocelyn; West, Stephen M., E-mail: Alistair.Butcher.2010@live.rhul.ac.uk, E-mail: Russell.Kirk.2008@live.rhul.ac.uk, E-mail: Jocelyn.Monroe@rhul.ac.uk, E-mail: Stephen.West@rhul.ac.uk [Department of Physics, Royal Holloway University of London, Egham, Surrey, TW20 0EX (United Kingdom)

    2017-10-01

    Models of nuclear dark matter propose that the dark sector contains large composite states consisting of dark nucleons in analogy to Standard Model nuclei. We examine the direct detection phenomenology of a particular class of nuclear dark matter model at the current generation of tonne-scale liquid noble experiments, in particular DEAP-3600 and XENON1T. In our chosen nuclear dark matter scenario distinctive features arise in the recoil energy spectra due to the non-point-like nature of the composite dark matter state. We calculate the number of events required to distinguish these spectra from those of a standard point-like WIMP state with a decaying exponential recoil spectrum. In the most favourable regions of nuclear dark matter parameter space, we find that a few tens of events are needed to distinguish nuclear dark matter from WIMPs at the 3 σ level in a single experiment. Given the total exposure time of DEAP-3600 and XENON1T we find that at best a 2 σ distinction is possible by these experiments individually, while 3 σ sensitivity is reached for a range of parameters by the combination of the two experiments. We show that future upgrades of these experiments have potential to distinguish a large range of nuclear dark matter models from that of a WIMP at greater than 3 σ .

  13. Can tonne-scale direct detection experiments discover nuclear dark matter?

    International Nuclear Information System (INIS)

    Butcher, Alistair; Kirk, Russell; Monroe, Jocelyn; West, Stephen M.

    2017-01-01

    Models of nuclear dark matter propose that the dark sector contains large composite states consisting of dark nucleons in analogy to Standard Model nuclei. We examine the direct detection phenomenology of a particular class of nuclear dark matter model at the current generation of tonne-scale liquid noble experiments, in particular DEAP-3600 and XENON1T. In our chosen nuclear dark matter scenario distinctive features arise in the recoil energy spectra due to the non-point-like nature of the composite dark matter state. We calculate the number of events required to distinguish these spectra from those of a standard point-like WIMP state with a decaying exponential recoil spectrum. In the most favourable regions of nuclear dark matter parameter space, we find that a few tens of events are needed to distinguish nuclear dark matter from WIMPs at the 3 σ level in a single experiment. Given the total exposure time of DEAP-3600 and XENON1T we find that at best a 2 σ distinction is possible by these experiments individually, while 3 σ sensitivity is reached for a range of parameters by the combination of the two experiments. We show that future upgrades of these experiments have potential to distinguish a large range of nuclear dark matter models from that of a WIMP at greater than 3 σ .

  14. Combined use of T2-weighted and diffusion-weighted 3-T MR imaging for differentiating uterine sarcomas from benign leiomyomas

    International Nuclear Information System (INIS)

    Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Nakaura, Takeshi; Yanaga, Yumi; Hirai, Toshinori; Saito, Tetsuo; Katabuchi, Hidetaka

    2009-01-01

    The objective of our study was to compare diffusion-weighted imaging (DWI) alone and DWI combined with T2-weighted MRI for the differentiation of uterine sarcomas from benign leiomyomas. T2-weighted imaging and DWI were performed in 103 patients with 103 myometrial tumours, including 8 uterine sarcomas and 95 benign leiomyomas on 3-T MR imaging. The signal intensity (SI) of the tumour on T2-weighted images was quantified as the tumour-myometrium contrast ratio (TCR) by using the following formula: (SI tumour - SI myometrium )/SI myometrium . The TCR or apparent diffusion coefficient (ADC) value alone and then the ADC value combined with T2-weighted imaging were evaluated for differentiation between sarcomas and leiomyomas. The mean ADC value of sarcomas was 0.86 ± 0.11 x 10 -3 m 2 /s, which was significantly lower than that of leiomyomas 1.18 ± 0.24 x 10 -3 m 2 /s; however, there was a substantial overlap. The mean TCR of sarcomas was 0.66 ± 0.71, which was significantly higher than that of the leiomyomas, -0.37 ± 0.34; however, again, there was a considerable overlap. When ADC was less than 1.05 x 10 -3 mm 2 /s and TCR was greater than 0 this condition was considered to confirm a sarcoma; a combination of ADC and TCR achieved a significant improvement without any overlap between sarcomas and leiomyomas (sensitivity 100%, specificity 100%). Our preliminary results indicate that combined DWI and T2-weighted MR imaging is better than DWI alone in the differentiation of uterine sarcomas from benign leiomyomas. (orig.)

  15. Prostate cancer detection from model-free T1-weighted time series and diffusion imaging

    Science.gov (United States)

    Haq, Nandinee F.; Kozlowski, Piotr; Jones, Edward C.; Chang, Silvia D.; Goldenberg, S. Larry; Moradi, Mehdi

    2015-03-01

    The combination of Dynamic Contrast Enhanced (DCE) images with diffusion MRI has shown great potential in prostate cancer detection. The parameterization of DCE images to generate cancer markers is traditionally performed based on pharmacokinetic modeling. However, pharmacokinetic models make simplistic assumptions about the tissue perfusion process, require the knowledge of contrast agent concentration in a major artery, and the modeling process is sensitive to noise and fitting instabilities. We address this issue by extracting features directly from the DCE T1-weighted time course without modeling. In this work, we employed a set of data-driven features generated by mapping the DCE T1 time course to its principal component space, along with diffusion MRI features to detect prostate cancer. The optimal set of DCE features is extracted with sparse regularized regression through a Least Absolute Shrinkage and Selection Operator (LASSO) model. We show that when our proposed features are used within the multiparametric MRI protocol to replace the pharmacokinetic parameters, the area under ROC curve is 0.91 for peripheral zone classification and 0.87 for whole gland classification. We were able to correctly classify 32 out of 35 peripheral tumor areas identified in the data when the proposed features were used with support vector machine classification. The proposed feature set was used to generate cancer likelihood maps for the prostate gland.

  16. Experimental acute intracerebral hemorrhage: Value of MR sequences for a safe diagnosis at 1.5 and 0.5 T

    International Nuclear Information System (INIS)

    Kueker, W.; Thron, A.; Thiex, R.; Rohde, I.; Rohde, V.

    2000-01-01

    To determine the detectability of intracerebral hematomas with MR imaging at 1.5 T and 0.5 T with fluid attenuated inversion recovery turbo spin-echo (FLAIR) and gradient-echo sequences. Material and Methods: Twenty-seven intracerebral hematomas were created in 25 piglets by injection of venous blood into the brain through a burr hole. All were imaged with T2*-weighted gradient echo sequences (fast field echo, FFE), T2-weighted fluid attenuated inversion recovery turbo spin-echo sequences (FLAIR), T2-weighted turbo spin-echo (TSE) and T1-weighted spin-echo sequences. Follow-up was performed on the 2nd, 4th and 10th postoperative days. Ten animals were additionally investigated with similar sequences at 0.5 T. Histologic correlation was obtained in all cases. Results: T2* FFE sequences detected all acute intracerebral hematomas and demonstrated the size correctly at 1.5 T and 0.5 T. The conspicuity was better at 1.5 T. FLAIR sequences were unreliable in the hyperacute phase at 1.5 T. However, subarachnoid and intraventricular extension was best appreciated with FLAIR images. T2 TSE images were incapable of detecting para ventricular and subarachnoid hemorrhages, but clearly demonstrated intracerebral blood in other locations. T1-weighted images were insensitive to hemorrhage in the acute state but very useful in subacute and chronic hematomas. Conclusion: The safe and reliable diagnosis of intracerebral hemorrhage is probably possible with MR imaging at 1.5 T and 0.5 T even of hematomas less than 90 min old, but requires the application of at least FLAIR, T2* FFE and T1 sequences and is therefore time consuming

  17. Natural implementation of neutralino dark matter

    International Nuclear Information System (INIS)

    King, Steve F.; Roberts, Jonathan P.

    2006-01-01

    The prediction of neutralino dark matter is generally regarded as one of the successes of the Minimal Supersymmetric Standard Model (MSSM). However the successful regions of parameter space allowed by WMAP and collider constraints are quite restricted. We discuss fine-tuning with respect to both dark matter and Electroweak Symmetry Breaking (EWSB) and explore regions of MSSM parameter space with non-universal gaugino and third family scalar masses in which neutralino dark matter may be implemented naturally. In particular allowing non-universal gauginos opens up the bulk region that allows Bino annihilation via t-channel slepton exchange, leading to 'supernatural dark matter' corresponding to no fine-tuning at all with respect to dark matter. By contrast we find that the recently proposed 'well tempered neutralino' regions involve substantial fine-tuning of MSSM parameters in order to satisfy the dark matter constraints, although the fine tuning may be ameliorated if several annihilation channels act simultaneously. Although we have identified regions of 'supernatural dark matter' in which there is no fine tuning to achieve successful dark matter, the usual MSSM fine tuning to achieve EWSB always remains

  18. Natural implementation of neutralino dark matter

    Science.gov (United States)

    King, Steve F.; Roberts, Jonathan P.

    2006-09-01

    The prediction of neutralino dark matter is generally regarded as one of the successes of the Minimal Supersymmetric Standard Model (MSSM). However the successful regions of parameter space allowed by WMAP and collider constraints are quite restricted. We discuss fine-tuning with respect to both dark matter and Electroweak Symmetry Breaking (EWSB) and explore regions of MSSM parameter space with non-universal gaugino and third family scalar masses in which neutralino dark matter may be implemented naturally. In particular allowing non-universal gauginos opens up the bulk region that allows Bino annihilation via t-channel slepton exchange, leading to ``supernatural dark matter'' corresponding to no fine-tuning at all with respect to dark matter. By contrast we find that the recently proposed ``well tempered neutralino'' regions involve substantial fine-tuning of MSSM parameters in order to satisfy the dark matter constraints, although the fine tuning may be ameliorated if several annihilation channels act simultaneously. Although we have identified regions of ``supernatural dark matter'' in which there is no fine tuning to achieve successful dark matter, the usual MSSM fine tuning to achieve EWSB always remains.

  19. Automated volumetric assessment of the Achilles tendon (AVAT) using a 3D T2 weighted SPACE sequence at 3 T in healthy and pathologic cases

    International Nuclear Information System (INIS)

    Syha, R.; Würslin, C.; Ketelsen, D.; Martirosian, P.; Grosse, U.; Schick, F.; Claussen, C.D.; Springer, F.

    2012-01-01

    Purpose: Achilles tendinopathy has been reported to be frequently associated with increasing volume of the tendon. This work aims at reliable and accurate volumetric quantification of the Achilles tendon using a newly developed contour detection algorithm applied on high resolution MRI data sets recorded at 3 T. Materials and methods: A total of 26 healthy tendons and 4 degenerated tendons were examined for this study. Automated identification (AI) of tendon boundaries was performed in transverse slices with isotropic resolution (0.8 mm) gained with a T2-weighted SPACE sequence at 3 T. For AI a snake algorithm was applied and compared to manual tracing (MT). Results: AI was feasible in all examined tendons without further correction. AI of both tendons was performed in each participant within 2 min (2 × 37 slices) compared to MT lasting 20 min. MT and AI showed excellent agreement and correlation (R 2 = 0.99, p 3 vs. 0.5 cm 3 ) and coefficient of variation (1% vs. 2%). Discussion: Compared to MT the AI allows assessment of tendon volumes in highly resolved MRI data in a more accurate and reliable time-saving way. Therefore automated volume detection is seen as a helpful clinical tool for evaluation of small volumetric changes of the Achilles tendon.

  20. The impact of the phase-space density on the indirect detection of dark matter

    International Nuclear Information System (INIS)

    Ferrer, Francesc; Hunter, Daniel R.

    2013-01-01

    We study the indirect detection of dark matter when the local dark matter velocity distribution depends upon position, as expected for the Milky Way and its dwarf spheroidal satellites, and the annihilation cross-section is not purely s-wave. Using a phase-space distribution consistent with the dark matter density profile, we present estimates of cosmic and gamma-ray fluxes from dark matter annihilations. The expectations for the indirect detection of dark matter can differ significantly from the usual calculation that assumes that the velocity of the dark matter particles follows a Maxwell-Boltzmann distribution

  1. Constraints on interacting dark energy models from Planck 2015 and redshift-space distortion data

    Energy Technology Data Exchange (ETDEWEB)

    Costa, André A.; Abdalla, E. [Instituto de Física, Universidade de São Paulo, C.P. 66318, 05315-970, São Paulo, SP (Brazil); Xu, Xiao-Dong [Department of Mathematics and Applied Mathematics, University of Cape Town, Rondebosch 7701, Cape Town (South Africa); Wang, Bin, E-mail: alencar@if.usp.br, E-mail: xiaodong.xu@uct.ac.za, E-mail: wang_b@sjtu.edu.cn, E-mail: eabdalla@usp.br [Department of Physics and Astronomy, Shanghai Jiao Tong University, 200240 Shanghai (China)

    2017-01-01

    We investigate phenomenological interactions between dark matter and dark energy and constrain these models by employing the most recent cosmological data including the cosmic microwave background radiation anisotropies from Planck 2015, Type Ia supernovae, baryon acoustic oscillations, the Hubble constant and redshift-space distortions. We find that the interaction in the dark sector parameterized as an energy transfer from dark matter to dark energy is strongly suppressed by the whole updated cosmological data. On the other hand, an interaction between dark sectors with the energy flow from dark energy to dark matter is proved in better agreement with the available cosmological observations. This coupling between dark sectors is needed to alleviate the coincidence problem.

  2. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

    Science.gov (United States)

    Hussain, Shahid M; De Becker, Jan; Hop, Wim C J; Dwarkasing, Soendersing; Wielopolski, Piotr A

    2005-03-01

    To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence. (c) 2005 Wiley-Liss, Inc.

  3. Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences

    International Nuclear Information System (INIS)

    Heiler, Patrick Michael; Schad, Lothar Rudi; Schmitter, Sebastian

    2010-01-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2 * -weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately √2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2 * -weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  4. Value of black blood T2* cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Carpenter John Paul

    2011-03-01

    Full Text Available Abstract Purpose To assess whether black blood T2* cardiovascular magnetic resonance is superior to conventional white blood imaging of cardiac iron in patients with thalassaemia major (TM. Materials and methods We performed both conventional white blood and black blood T2* CMR sequences in 100 TM patients to determine intra and inter-observer variability and presence of artefacts. In 23 patients, 2 separate studies of both techniques were performed to assess interstudy reproducibility. Results Cardiac T2* values ranged from 4.5 to 43.8 ms. The mean T2* values were not different between black blood and white blood acquisitions (20.5 vs 21.6 ms, p = 0.26. Compared with the conventional white blood diastolic acquisition, the coefficient of variance of the black blood CMR technique was superior for intra-observer reproducibility (1.47% vs 4.23%, p Conclusions Black blood T2* CMR has superior reproducibility and reduced imaging artefacts for the assessment of cardiac iron, in comparison with the conventional white blood technique, which make it the preferred technique for clinical practice.

  5. Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma

    International Nuclear Information System (INIS)

    Both, M.; Schultze, J.; Reuter, M.; Bewig, B.; Hubner, R.; Bobis, I.; Noth, R.; Heller, M.; Biederer, J.

    2005-01-01

    Purpose: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. Material and methods: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ('VIBE', TR/TE 4.5/1.9 ms, flip-angle 12 deg., matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). Results: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. Conclusion: The combination of VIBE and HASTE sequence allows for an adequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to

  6. Fast FLAIR MR imaging finidngs of cerebral infarction : comparison with T2-weighted spin echo imaging

    International Nuclear Information System (INIS)

    Kong, Keun Young; Choi, Woo Suk; Kim, Eui Jong

    1997-01-01

    To evaluate the utility of FLAIR(Fluid Attenuated Inversion Recovery) MR imaging in cerebral infarction by comparing its results with those of T2-weighted spin-echo imaging. We retrospectively evaluated fast FLAIR images and conventional spin echo images of 82 patients (47 men and 20 women ; median age 60.9 years) with cerebral infarction. MR imaging used a 1.5T MR unit with conventional T2(TR 3900, TE 90) and fast FLAIR sequence (TR 8000, TE 105, TI 2400). We analysed the size of the main lesion and number of lesions, and discrimination between old and new lesions and between small infarction and perivascular space. When T2-weighted and FLAIR imaging were compared, the latter showed that the main lesion was larger in 38 cases (46%), similar in 38 (46%), and smaller in six (7%). The number of lesions was greater in 23 cases(28%), similar in 52 (63%), and fewer in seven (9%). FLAIR images discriminated between old and new lesions in 31 cases ; perivascular space and small infarotion were differentiated in eight cases, and CSF inflowing artifact was observed in 66 (80%). In the diagnosis of cerebral infaretion, fast FLAIR provides images that are equal or superior to T2-weighted images. The fast FLAIR sequence may therefore be used as a part of routine MR brain study in the diagnosis of cerebral infarction

  7. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    Energy Technology Data Exchange (ETDEWEB)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali [Erciyes University Medical School, Department of Radiology, Kayseri (Turkey); Kumandas, Sefer [Erciyes University Medical School, Department of Neuropediatry, Kayseri (Turkey); Akcakus, Mustafa [Erciyes University Medical School, Department of Neonatalogy, Kayseri (Turkey)

    2005-06-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  8. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    International Nuclear Information System (INIS)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali; Kumandas, Sefer; Akcakus, Mustafa

    2005-01-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  9. Evaluation of the effects of Bacillus subtilis and Bacillus Licheni formis promix on blood metabolites and elements and weight gain in rearing calves

    Directory of Open Access Journals (Sweden)

    Gh Moghaddam

    2007-05-01

    Full Text Available Probiotics are beneficial microorganisms which are colonized in the digestive system of livestock and influence some of the blood parameters through special mechanisms. For this purpose, an experiment was conducted to clarify the influence of promix containing living spores of the two bacteria Bacillus subtilis and Bacillus licheniformis on body weight gain, blood metabolites and elements of calves. Twenty male Holstein calves were divided into two groups of ten calves and kept at separate bans. The control group were fed with a standard ration and the treatment group were fed with the same ration plus promix (1.6 × 109 cfu/g feed or 500 g/T feed for 45 days. Calves were weighed in the 1st, 15th, 30th and 45th days and blood samples were collected for measurement of some metabolites and blood elements. The obtained means were compared using the T- test. The results indicated that the average daily weight gain using promix had a non-significant improvement of 4.8% (p>0.05. Also the average daily weight gain showed a non significant improvement in each of the 3 experimental periods (p>0.05. Blood phosphorus and calcium of calves increased significantly influenced by promix with the increase being non significant in the first experimental period and significant in the second and third periods (p

  10. WeightLifter: Visual Weight Space Exploration for Multi-Criteria Decision Making.

    Science.gov (United States)

    Pajer, Stephan; Streit, Marc; Torsney-Weir, Thomas; Spechtenhauser, Florian; Muller, Torsten; Piringer, Harald

    2017-01-01

    A common strategy in Multi-Criteria Decision Making (MCDM) is to rank alternative solutions by weighted summary scores. Weights, however, are often abstract to the decision maker and can only be set by vague intuition. While previous work supports a point-wise exploration of weight spaces, we argue that MCDM can benefit from a regional and global visual analysis of weight spaces. Our main contribution is WeightLifter, a novel interactive visualization technique for weight-based MCDM that facilitates the exploration of weight spaces with up to ten criteria. Our technique enables users to better understand the sensitivity of a decision to changes of weights, to efficiently localize weight regions where a given solution ranks high, and to filter out solutions which do not rank high enough for any plausible combination of weights. We provide a comprehensive requirement analysis for weight-based MCDM and describe an interactive workflow that meets these requirements. For evaluation, we describe a usage scenario of WeightLifter in automotive engineering and report qualitative feedback from users of a deployed version as well as preliminary feedback from decision makers in multiple domains. This feedback confirms that WeightLifter increases both the efficiency of weight-based MCDM and the awareness of uncertainty in the ultimate decisions.

  11. Origins Space Telescope: Tracing Dark Molecular Gas in the Milky Way

    Science.gov (United States)

    Narayanan, Desika; Li, Qi; Krumholz, Mark; Dave, Romeel; Origins Space Telescope Science and Technology Definition Team

    2018-01-01

    We present theoretical models for quantifying the fraction of CO-dark molecular gas in galaxies. To do this, we combine novel thermal, chemical, and radiative equilibrium calculations with high-resolution cosmological zoom galaxy formation models. We discuss how this dark molecular gas will be uncovered by the Origins Space Telescope, one of the four science and technology definition studies of NASA Headquarters for the 2020 Astronomy and Astrophysics Decadal survey.

  12. Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter

    2016-02-01

    To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.

  13. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  14. Carotid plaque signal differences among four kinds of T1-weighted magnetic resonance imaging techniques: A histopathological correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Ayumi; Narumi, Shinsuke; Ohba, Hideki; Yamaguchi, Mao; Terayama, Yasuo [Iwate Medical University, Department of Neurology and Gerontology, Morioka (Japan); Sasaki, Makoto; Kudo, Kohsuke [Iwate Medical University, Institute for Biomedical Sciences, Morioka (Japan); Ogasawara, Kuniaki; Kobayashi, Masakazu [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Hitomi, Jiro [Iwate Medical University, Department of Anatomy, Morioka (Japan)

    2012-11-15

    Several magnetic resonance (MR) imaging techniques are used to examine atherosclerotic plaque of carotid arteries; however, the best technique for visualizing intraplaque characteristics has yet to be determined. Here, we directly compared four kinds of T1-weighted (T1W) imaging techniques with pathological findings in patients with carotid stenosis. A total of 31 patients who were candidates for carotid endarterectomy were prospectively examined using a 1.5-T MRI scanner, which produced four kinds of T1W images, including non-gated spin echo (SE), cardiac-gated black-blood (BB) fast-SE (FSE), magnetization-prepared rapid acquisition with gradient echo (MPRAGE), and source image of three-dimensional time-of-flight MR angiography (SI-MRA). The signal intensity of the carotid plaque was manually measured, and the contrast ratio (CR) against the adjacent muscle was calculated. CRs from the four imaging techniques were compared to each other and correlated with histopathological specimens. CRs of the carotid plaques mainly containing fibrous tissue, lipid/necrosis, and hemorrhage were significantly different with little overlaps (range: 0.92-1.15, 1.22-1.52, and 1.55-2.30, respectively) on non-gated SE. However, BB-FSE showed remarkable overlaps among the three groups (0.89-1.10, 1.07-1.23, and 1.01-1.42, respectively). MPRAGE could discriminate fibrous plaques from hemorrhagic plaques but not from lipid/necrosis-rich plaques: (0.77-1.07, 1.45-2.43, and 0.85-1.42, respectively). SI-MRA showed the same tendencies (1.01-1.39, 1.45-2.57, and 1.12-1.39, respectively). Among T1W MR imaging techniques, non-gated SE images can more accurately characterize intraplaque components in patients who underwent CEA when compared with cardiac-gated BB-FSE, MPRAGE, and SI-MRA images. (orig.)

  15. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    International Nuclear Information System (INIS)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo

    1994-01-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author)

  16. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-09-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author).

  17. Non-severe hypoglycaemia is associated with weight gain in patients with type 1 diabetes: Results from the Diabetes Control and Complication Trial.

    Science.gov (United States)

    Bumbu, Anisoara; Moutairou, Abdul; Matar, Odette; Fumeron, Frédéric; Velho, Gilberto; Riveline, Jean-Pierre; Gautier, Jean-François; Marre, Michel; Roussel, Ronan; Potier, Louis

    2018-05-01

    It is unclear whether the frequent non-severe episodes of hypoglycaemia observed during intensive glucose control in individuals with type 1 diabetes (T1D) are associated with subsequent weight gain. We analysed the association between non-severe hypoglycaemia and weight gain in 1441 Diabetes Control and Complication Trial (DCCT) participants. Non-severe hypoglycaemia was assessed by hypo-score (ie, number of blood glucose values gain. The annual weight gain by hypo-score tertiles was 0.8 ± 1.2 (T1), 1.3 ± 1.5 (T2) and 1.4 ± 1.3 kg/y (T3), P gain of 1.8 kg/y was 2.14 (95% CI, 1.56-2.93) for T2, and 2.53 (95%CI, 1.85-3.45) for T3 vs T1. These differences in weight gain and in risk of weight gain remained significant after adjustment for sex, age, duration of diabetes, HbA1c at baseline and treatment arms. In conclusion, our analysis shows a significant association between non-severe hypoglycaemia and weight gain in individuals with T1D from the DCCT. © 2017 John Wiley & Sons Ltd.

  18. Comparison of fast spin echo, fast multiplanner spoiled gradient recalled and conventional T1 and T2 weighted imaging for experimentally induced hepatic tumors in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Suh, Jin Suk; Choi, Pil Sik; Lee, Yeon Hee; Yoo, Hyung Sik; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To compare the ability of tumor detection and the lesion conspicuity between T1- and T2-weighted fast scanning sequence and T1- and T2-weighted conventional spin echo techniques in MR imaging of hepatic tumors. Hepatic tumors were induced on 13 male Sprague-Dawley rats by feeding 3'-methyl-dimethylethyl aminoazobenzene mixed with Miller's III formula for 12 weeks. MR images were obtained with 1.5 T magnet with dual TMJ coil(Sigma, GE Medical systems, Milwaukee, USA). Animals were anesthetized with 150 mg/kg of ketamine hydrochloride. T2 weighted fast spin echo(FSE), conventional spin echo(CSE) T2- and T1WI, fast multiplanner spoiled gradient recalled(FMPSPGR) imaging were obtained. Number of detected tumors and contrast-to-noise ratio of the tumors were compared for each sequence. Overall 110 tumors were developed. 75% of the tumors were detected on FSE. 65% on FMPSPGR, 41% on conventional T2WI, and 41% on T1WI images. For tumors more than 5 mm in diameter, sensitivity was 88% on FMPSPGR, 65% on conventional T2WI, and 81% on T1WI images respectively. CNR of the tumor was 28.94 {+-} 21.6 on FSE, 13.57 {+-} 8.64 on FMPSPGR, 12.62 {+-} 10.65 on CSE T2WI, and 9.47 {+-} 8.05 on CSE T1WI images, which was significantly high on FSE(p<0.05). Fast spin echo T2WI shows highest sensitivity and tumor-to-liver contrast. FMPSPGR imaging is also favorably comparable with conventional T1WI. Therefore, these two pulse sequences can be useful in clinical condition for hepatic MR imaging.

  19. Comparison among T1-weighted magnetic resonance imaging, modified dixon method, and magnetic resonance spectroscopy in measuring bone marrow fat.

    Science.gov (United States)

    Shen, Wei; Gong, Xiuqun; Weiss, Jessica; Jin, Ye

    2013-01-01

    An increasing number of studies are utilizing different magnetic resonance (MR) methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI), modified Dixon method (also called fat fraction MRI (FFMRI)), and magnetic resonance spectroscopy (MRS). Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI). Bone marrow adipose tissue (BMAT) of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 (P BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 (P < 0.001) in femoral necks. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  20. Comparison between T2*- and T2-weighted images in diagnosing rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo; Ito, Hisao; Kubo, Atsushi.

    1995-01-01

    This study was performed to determine the merits of T2 * -weighted images in diagnosing rotator cuff tear, compared with T2-weighted images. T2- and T2 * -weighted images were obtained in 10 asymptomatic volunteers and 94 patients with symptoms referable to the rotator cuff. The increased signal with full thickness of the rotator cuff was not shown on either T2- or T2 * -weighted images in the volunteers. These findings on T2-weighted images and on T2 * -weighted images were observed in 33 and 58 of 94 patients with symptoms, respectively. Every patient who showed these abnormal findings on T2-weighted images had the abnormal findings on T2 * -weighted images. These findings on T2 * -weighted images were wider than those on T2-weighted images in 20 of 33 patients. Surgical findings were available in 21 of 94 patients. Rotator cuff tears were surgically confirmed in 20 patients whose MR images showed increased signal lesions on both T2- and T2 * -weighted images. On the other hand, one patient who did not have rotator cuff tear showed increased signal lesion with full thickness on T2 * -weighted images, but not on T2-weighted images. We think increased signal lesions on T2-weighted images may strongly suggest rotator cuff tear, whereas those on T2 * -weighted images are not specific. (author)

  1. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    Energy Technology Data Exchange (ETDEWEB)

    Cassinotto, Christophe, E-mail: christophe.cassinotto@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); INSERM U1053, Université Bordeaux, Bordeaux (France); Feldis, Matthieu, E-mail: matthieu.feldis@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Vergniol, Julien, E-mail: julien.vergniol@chu-bordeaux.fr [Centre D’investigation de la Fibrose Hépatique, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Mouries, Amaury, E-mail: amaury.mouries@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Cochet, Hubert, E-mail: hubert.cochet@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); and others

    2015-08-15

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan{sup ®} as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic

  2. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    International Nuclear Information System (INIS)

    Cassinotto, Christophe; Feldis, Matthieu; Vergniol, Julien; Mouries, Amaury; Cochet, Hubert

    2015-01-01

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan ® as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic tool for

  3. Quantitative and qualitative evaluation of brain diffusion weighted magnetic resonance imaging comparison with 1.5 T and 3.0 T units

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Eun Hoe [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-02-15

    DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging . In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5 T and 3.0 T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5 T.

  4. Diagnostic Utility of Contrast-enhanced 3D T1-weighted Imaging in Acute Cerebral Infarction Associated with Graves Disease.

    Science.gov (United States)

    Gon, Yasufumi; Sakaguchi, Manabu; Oyama, Naoki; Mochizuki, Hideki

    2017-02-01

    Graves disease is rarely complicated with cerebrovascular steno-occlusive diseases. Previous studies have suggested several hypotheses for this occurrence, including excess thyroid hormone, which stimulates the sympathetic nervous system, which in turn causes an abnormal hemodynamic response with consequent atherosclerotic changes, and antithyroid antibodies cause local vascular inflammation in patients with Graves disease. However, radiological findings of vasculitis in patients with Graves disease and cerebral infarction remain less known. We report the case of a 30-year-old Japanese woman with acute cerebral infarction due to vasculitis associated with Graves disease. She was admitted to our hospital with a 4-day history of intermittent transient dysarthria and limb shaking of the left leg when standing. Three weeks before admission, she went to a local hospital because of general malaise and was diagnosed with Graves disease. Neurological examination revealed paralytic dysarthria, left central facial nerve palsy, and left hemiparesis (manual muscle testing, 4 of 5). Blood examinations showed hyperthyroidism (thyroid-stimulating hormone ≤.010 µU/mL; free T3 ≥25.0 pg/mL; free T4 ≥8.0 ng/dL) and elevation of antithyroid antibody levels (thyroid peroxidase antibody, 87 IU/mL). The vessel wall of the right internal carotid artery was markedly enhanced on contrast-enhanced three-dimensional T1-weighted magnetic resonance imaging, suggesting vasculitis. Magnetic resonance angiography revealed right internal carotid artery occlusion after the branching ophthalmic artery. Arterial stenosis due to vasculitis was considered the cause of hemodynamic ischemic stroke. Vessel wall imaging such as high-resolution contrast-enhanced T1-weighted imaging seems useful for assessing the underlying mechanism of stroke in patients with Graves disease. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. Highest weight generating functions for hyperKähler T{sup ⋆}(G/H) spaces

    Energy Technology Data Exchange (ETDEWEB)

    Hanany, Amihay [Theoretical Physics Group, Imperial College London,Prince Consort Road, London, SW7 2AZ (United Kingdom); Ramgoolam, Sanjaye [Centre for Research in String Theory,School of Physics and Astronomy, Queen Mary University of London,Mile End Road, London E1 4NS (United Kingdom); Rodriguez-Gomez, Diego [Department of Physics, Universidad de Oviedo,Avda. Calvo Sotelo 18, 33007, Oviedo (Spain)

    2016-10-05

    We develop an efficient procedure for counting holomorphic functions on a hyperKahler cone that has a resolution as a cotangent bundle of a homogeneous space by providing a formula for computing the corresponding Highest Weight Generating function.

  6. Prevalence of human T-cell lymphotropic virus types 1 and 2 in blood donors of the Caruaru Blood Center (Hemope

    Directory of Open Access Journals (Sweden)

    Waleska Mayara Gomes de Lima

    2013-01-01

    Full Text Available BACKGROUND: There is difficulty in gathering data on the prevalence of human T-cell lymphotropic virus in blood donors as confirmatory testing is not mandatory in Brazil. This suggests there may be an underreporting of the prevalence. OBJECTIVE: To estimate the prevalence of human T-cell lymphotropic virus types 1 and 2 in donors of a blood bank in Caruaru, Brazil. METHODS: This was an observational, epidemiological, descriptive, longitudinal and retrospective study with information about the serology of donors of the Caruaru Blood Center, Fundação de Hematologia e Hemoterapia de Pernambuco (Hemope from May 2006 to December 2010. The data were analyzed using the Excel 2010 computer program (Microsoft Office(r. RESULTS: Of 61,881 donors, 60 (0.096% individuals were identified as potential carriers of human T-cell lymphotropic virus types 1 and 2. Of these, 28 (0.045% were positive and 32 (0.051% had inconclusive results in the serological screening. Forty-five (0.072% were retested; 17 were positive (0.027% and 3 inconclusive (0.005%. After confirmatory tests, 8 were positive (0.013%. Six (75% of the confirmed cases were women. CONCLUSION: Epidemiological surveys like this are very important in order to create campaigns to attract donors and reduce the costs of laboratory tests.

  7. Artifact free T2{sup *}-weighted imaging at high spatial resolution using segmented EPI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Heiler, Patrick Michael; Schad, Lothar Rudi [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Schmitter, Sebastian [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiology

    2010-07-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2{sup *}-weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately {radical}2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2{sup *}-weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  8. Fractional multilinear integrals with rough kernels on generalized weighted Morrey spaces

    Directory of Open Access Journals (Sweden)

    Akbulut Ali

    2016-01-01

    Full Text Available In this paper, we study the boundedness of fractional multilinear integral operators with rough kernels TΩ,αA1,A2,…,Ak,$T_{\\Omega ,\\alpha }^{{A_1},{A_2}, \\ldots ,{A_k}},$ which is a generalization of the higher-order commutator of the rough fractional integral on the generalized weighted Morrey spaces Mp,ϕ (w. We find the sufficient conditions on the pair (ϕ1, ϕ2 with w ∈ Ap,q which ensures the boundedness of the operators TΩ,αA1,A2,…,Ak,$T_{\\Omega ,\\alpha }^{{A_1},{A_2}, \\ldots ,{A_k}},$ from Mp,φ1wptoMp,φ2wq${M_{p,{\\varphi _1}}}\\left( {{w^p}} \\right\\,{\\rm{to}}\\,{M_{p,{\\varphi _2}}}\\left( {{w^q}} \\right$ for 1 < p < q < ∞. In all cases the conditions for the boundedness of the operator TΩ,αA1,A2,…,Ak,$T_{\\Omega ,\\alpha }^{{A_1},{A_2}, \\ldots ,{A_k}},$ are given in terms of Zygmund-type integral inequalities on (ϕ1, ϕ2 and w, which do not assume any assumption on monotonicity of ϕ1 (x,r, ϕ2(x, r in r.

  9. Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T

    International Nuclear Information System (INIS)

    Durighel, G.; Tokarczuk, P.F.; Karsa, A.; Gordon, F.; Cook, S.A.; O'Regan, D.P.

    2016-01-01

    Aim: To assess whether susceptibility-weighted imaging (SWI) provides better image contrast for the detection of haemorrhagic ischaemia–reperfusion injury in the heart. Materials and methods: Thirty patients (all men; mean age 53 years) underwent cardiac magnetic resonance imaging (MRI) within 7 days of primary percutaneous intervention for acute ST elevation myocardial infarction (STEMI). Multiple gradient-echo T2* sequences with magnitude and phase reconstructions were acquired. A high-pass filtered phase map was used to create a mask for the SWI reconstructions. The difference in image contrast was assessed in those patients with microvascular obstruction. A mixed effects regression model was used to test the effect of echo time and reconstruction method on phase and contrast-to-noise ratio (CNR). Medians and interquartile ranges (IQR) are reported. Results: T2* in haemorrhagic infarcts was shorter than in non-haemorrhagic infarcts (33.5 ms [24.9–43] versus 49.9 ms [44.6–67.6]; p=0.0007). The effect of echo time on phase was significant (p<0.0001), as was the effect of haemorrhage on phase (p=0.0016). SWI reconstruction had a significant effect on the CNR at all echo times (echoes 1–5, p<0.0001; echo 6, p=0.01; echo 7, p=0.02). The median echo number at which haemorrhage was first visible was less for SWI compared to source images (echo 2 versus echo 5, p=0.0002). Conclusion: Cardiac SWI improves the contrast between myocardial haemorrhage and the surrounding tissue following STEMI and has potential as a new tool for identifying patients with ischaemia–reperfusion injury. - Highlights: • Cardiac susceptibility-weighted imaging (SWI) is feasible at 1.5T. • Combining phase and modulus data allows blood products to be seen at shorter echo times. • This sequence improves visualisation of reperfusion myocardial haemorrhage.

  10. Interactive thresholded volumetry of abdominal fat using breath-hold T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wittsack, H.J.; Cohnen, M.; Jung, G.; Moedder, U.; Poll, L.; Kapitza, C.; Heinemann, L.

    2006-01-01

    Purpose: development of a feasible and reliable method for determining abdominal fat using breath-hold T1-weighted magnetic resonance imaging. Materials and methods: the high image contrast of T1-weighted gradient echo MR sequences makes it possible to differentiate between abdominal fat and non-fat tissue. To obtain a high signal-to-noise ratio, the measurements are usually performed using phased array surface coils. Inhomogeneity of the coil sensitivity leads to inhomogeneity of the image intensities. Therefore, to examine the volume of abdominal fat, an automatic algorithm for intensity correction must be implemented. The analysis of the image histogram results in a threshold to separate fat from other tissue. Automatic segmentation using this threshold results directly in the fat volumes. The separation of intraabdominal and subcutaneous fat is performed by interactive selection in a last step. Results: the described correction of inhomogeneity allows for the segmentation of the images using a global threshold. The use of semiautomatic interactive volumetry makes the analysis more subjective. The variance of volumetry between observers was 4.6%. The mean time for image analysis of a T1-weighted investigation lasted less than 6 minutes. Conclusion: the described method facilitates reliable determination of abdominal fat within a reasonable period of time. Using breath-hold MR sequences, the time of examination is less than 5 minutes per patient. (orig.)

  11. Quark seesaw mechanism, dark U (1 ) symmetry, and the baryon-dark matter coincidence

    Science.gov (United States)

    Gu, Pei-Hong; Mohapatra, Rabindra N.

    2017-09-01

    We attempt to understand the baryon-dark matter coincidence problem within the quark seesaw extension of the standard model where parity invariance is used to solve the strong C P problem. The S U (2 )L×S U (2 )R×U (1 )B -L gauge symmetry of this model is extended by a dark U (1 )X group plus inclusion of a heavy neutral vector-like fermion χL ,R charged under the dark group which plays the role of dark matter. All fermions are Dirac type in this model. Decay of heavy scalars charged under U (1 )X leads to simultaneous asymmetry generation of the dark matter and baryons after sphaleron effects are included. The U (1 )X group not only helps to stabilize the dark matter but also helps in the elimination of the symmetric part of the dark matter via χ -χ ¯ annihilation. For dark matter mass near the proton mass, it explains why the baryon and dark matter abundances are of similar magnitude (the baryon-dark matter coincidence problem). This model is testable in low threshold (sub-keV) direct dark matter search experiments.

  12. Comparison among T1-Weighted Magnetic Resonance Imaging, Modified Dixon Method, and Magnetic Resonance Spectroscopy in Measuring Bone Marrow Fat

    Directory of Open Access Journals (Sweden)

    Wei Shen

    2013-01-01

    Full Text Available Introduction. An increasing number of studies are utilizing different magnetic resonance (MR methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI, modified Dixon method (also called fat fraction MRI (FFMRI, and magnetic resonance spectroscopy (MRS. Methods. Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI. Bone marrow adipose tissue (BMAT of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Results. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 in the L3 vertebra. Correlation between BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 in femoral necks. Conclusion. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  13. Recombinant Erythropoietin And Blood Transfusion In Very Low Birth Weight Infants

    Directory of Open Access Journals (Sweden)

    Keramat Nouri

    2005-05-01

    Full Text Available Backgroundp: Very low birth weight infants ( <1500 g frequently require blood transfusions because of repeated blood sampling accompanied by anemia of prematurity. Methods: In an attempt to identify the effect of human recombinant erythropoietin to decrease the requirement for blood transfusions, erythropoietin was administered to 24 pre term infants less than 1500 g prospectively from September 1999 till December2000. Data about the characteristics of the population, the severity of diseases, and treatment with erythropoietin, clinical diagnosis, initial and subsequent hemoglobin, volume of blood loss, and the number of blood transfusions were recorded. These results were compared with data from the recorded information of 49 infants who did not receive erythropoietin during those past 2 years. There were no differences between the 2 groups with regard to the gestational age, birth weight, clinical diagnosis, severity of the illness, primary causes of admission, and initial hematologic parameters such as hemoglobin, hematocrit and reticulocytes. Erythropoietin was administered in a dose of 200 ill/kg three times weekly for 6-8 weeks accompanied with iron supplement 6 mg/ kg/day. Transfusions were administered according to protocol. Results: There was no significant difference between the number of blood transfusion among these 2 groups (p= 0.07. However, transfusions in the erythropoietin treated group were fewer in comparison to the other group (1.9 +1-1.6 to 3.2 +/-1.1. No difference was observed between final hemoglobin and hematocrit levels among the two groups (10.3 +1- 0.9 vs. 10.4 +1- 0.7 and 33.7 +1- 2.3 vs. 32.2 +1- 2.2. Conclusion: Very low birth weight infants receive frequent blood transfusions but a reduction in transfusion requirements was not apparent after administration of erythropoietin and iron in preterm infants in this study. However, the lack of impact on transfusion requirements fails to support routine use of

  14. New MRI findings in Creutzfeldt-Jakob disease: high signal in the globus pallidus on T 1-weighted images

    International Nuclear Information System (INIS)

    Priester, J.A. de; Wilmink, J.T.; Jansen, G.H.; Kruijk, J.R. de

    1999-01-01

    We report a 49-year-old woman with Creutzfeldt-Jakob disease (CJD). In addition to typical high-signal lesions on proton-density and T 2-weighted images there was high signal in the globus pallidus bilaterally on T 1-weighted images. The latter feature has not been described previously and probably due to deposition of prion protein, as found at autopsy. (orig.)

  15. Hyperintense basal ganglia lesions on T1-weighted MR images in asymptomatic patients with hepatic dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Cila, A. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Dincer, F.F. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey)

    1995-12-31

    Cranial MRI findings in four patients who had hepatic dysfunction, including one with sole hepatic form of Wilson`s disease, were reported. The MR examinations revealed bilateral, symmetric hyperintensity in the globus pallidus, subthalamic nuclei and mesencephalon on T1-weighted images with no corresponding abnormality on T2-weighted sequences. The basal ganglia were normal on CT examinations in all patients. None of the patients had the clinical findings of hepatic encephalopathy. The MR findings in our patients did not correlate with the degree or duration of hepatic dysfunction. (orig.)

  16. Classification of hematopoietic regions in out-of-phase T{sub 1}-weighted images. A quantitative comparison study with T{sub 1}-weighted and STIR images

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Amano, Maki; Kijima, Tetsuji; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1995-07-01

    The hematopoietic regions were classified into two groups on the basis of out-of-phase T{sub 1}-weighted images (op-TlWI): regions with lower intensity than that of muscle (LH) and regions with intensity equal to or higher than that of muscle (HH). We quantitatively evaluated the differences in signal intensity between LH and HH in order to examine this classification. Forty-two hematopoietic areas in aplastic anemia were classified into two groups of 23 LH and 19 HH. The signal ratios of hematopoietic areas to muscle on TlWI and STIR were calculated, and the differences between LH and HH were statistically evaluated. The signal ratios of LH were significantly higher on TlWI and lower on STIR than those of HH (unpaired t-test, p<0.05). This result indicated that LH consisted of more hypocellular marrow than HH. Op-TlWI were useful in differentiating between LH and HH and defining the degree of hematopoiesis in aplastic anemia. (author).

  17. CASTing light on dark matter particles

    CERN Multimedia

    2005-01-01

    CERN's CAST collaboration recently released first results from its search for solar axions, a candidate dark matter particle. Though they haven't found any axions yet, they have done much to narrow the hunt. The CAST experiment. Physicists think the universe is permeated with dark matter, particles that don't emit or absorb radiation and so are invisible to traditional telescopes. So far no one has found direct signs of dark matter. A different breed of telescope, however, may be able to see such particles. CERN's Axion Solar Telescope (CAST), currently the world's only working axion helioscope, is a superconducting test magnet from the Large Hadron Collider (LHC) that has been refurbished and outfitted with X-ray detectors, plus a focusing mirror system for X-rays that was recovered from the German space program. CAST stares into the sun in search of particles called axions, one of the leading candidates for dark matter. On 9 November, the CAST collaboration released the results of their first experimen...

  18. Dark nebulae, dark lanes, and dust belts

    CERN Document Server

    Cooke, Antony

    2012-01-01

    As probably the only book of its type, this work is aimed at the observer who wants to spend time with something less conventional than the usual fare. Because we usually see objects in space by means of illumination of one kind or another, it has become routine to see them only in these terms. However, part of almost everything that we see is the defining dimension of dark shading, or even the complete obscuration of entire regions in space. Thus this book is focused on everything dark in space: those dark voids in the stellar fabric that mystified astronomers of old; the dark lanes reported in many star clusters; the magical dust belts or dusty regions that have given so many galaxies their identities; the great swirling 'folds' that we associate with bright nebulae; the small dark feature detectable even in some planetary nebulae; and more. Many observers pay scant attention to dark objects and details. Perhaps they are insufficiently aware of them or of the viewing potential they hold, but also it may be...

  19. Extrahepatic portal vein obstruction with parkinsonism and symmetric hyperintense basal ganglia on T1 weighted MRI

    Directory of Open Access Journals (Sweden)

    Jayalakshmi Sita

    2006-01-01

    Full Text Available Abnormal high signal in the globus pallidus on T1 weighted magnetic resonance imaging (MRI of the brain has been well described in patients with chronic liver disease. It may be related to liver dysfunction or portal-systemic shunting. We report a case of extra hepatic portal vein obstruction with portal hypertension and esophageal varices that presented with extra pyramidal features. T1 weighted MRI brain scans showed increased symmetrical signal intensities in the basal ganglia. Normal hepatic function in this patient emphasizes the role of portal- systemic communications in the development of these hyperintensities, which may be due to deposition of paramagnetic substances like manganese in the basal ganglia.

  20. New MRI findings in Creutzfeldt-Jakob disease: high signal in the globus pallidus on T 1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Priester, J.A. de; Wilmink, J.T. [Dept. of Radiology, University Hospital Maastricht (Netherlands); Jansen, G.H. [Department of Neuropathology, University Hospital Utrecht (Netherlands); Kruijk, J.R. de [Department of Neurology, University Hospital Maastricht (Netherlands)

    1999-04-01

    We report a 49-year-old woman with Creutzfeldt-Jakob disease (CJD). In addition to typical high-signal lesions on proton-density and T 2-weighted images there was high signal in the globus pallidus bilaterally on T 1-weighted images. The latter feature has not been described previously and probably due to deposition of prion protein, as found at autopsy. (orig.) With 3 figs., 11 refs.

  1. Dynamical 3-Space: Supernovae and the Hubble Expansion — the Older Universe without Dark Energy

    Directory of Open Access Journals (Sweden)

    Cahill R. T.

    2007-10-01

    Full Text Available We apply the new dynamics of 3-space to cosmology by deriving a Hubble expansion solution. This dynamics involves two constants; G and — the fine structure constant. This solution gives an excellent parameter-free fit to the recent supernova and gamma- ray burst redshift data without the need for “dark energy” or “dark matter”. The data and theory together imply an older age for the universe of some 14.7Gyrs. The 3-space dynamics has explained the bore hole anomaly, spiral galaxy flat rotation speeds, the masses of black holes in spherical galaxies, gravitational light bending and lensing, all without invoking “dark matter” or “dark energy”. These developments imply that a new understanding of the universe is now available.

  2. A Simple Singlet Fermionic Dark-Matter Model Revisited

    International Nuclear Information System (INIS)

    Qin Hong-Yi; Wang Wen-Yu; Xiong Zhao-Hua

    2011-01-01

    We evaluate the spin-independent elastic dark matter-nucleon scattering cross section in the framework of the simple singlet fermionic dark matter extension of the standard model and constrain the model parameter space with the following considerations: (i) new dark matter measurement, in which, apart from WMAP and CDMS, the results from the XENON experiment are also used in constraining the model; (ii) new fitted value of the quark fractions in nucleons, in which the updated value of f T s from the recent lattice simulation is much smaller than the previous one and may reduce the scattering rate significantly; (iii) new dark matter annihilation channels, in which the scenario where top quark and Higgs pairs produced by dark matter annihilation was not included in the previous works. We find that unlike in the minimal supersymmetric standard model, the cross section is just reduced by a factor of about 1/4 and dark matter lighter than 100 GeV is not favored by the WMAP, CDMS and XENON experiments. (the physics of elementary particles and fields)

  3. Imaging and measurement of T1 value by NMR of low magnetic field

    International Nuclear Information System (INIS)

    Asai, Hideaki; Izawa, Akira; Furuse, Kazuhiro; Saoi, Katsuyoshi; Nagai, Masahiko.

    1983-01-01

    FONAR QED-80α having two operating mode: the anatomy mode to obtain an image of proton densities and the chemistry mode to measure T 1 value at a region of intenst, was used clinically. The strength of static magnetic field is 0.041T. 32 cases, 18 healthy volunteers and 14 patients were studied. In proton density imaging, high proton density organs such as skin were imaged bright, and low proton density organs such as bones and flowing blood were imaged dark. The merits of NMR imaging are no artifacts caused by bones and air. However, NMR image is required long time for measurement and the image of NMR is unsharp than that of X-ray CT. Concerning with T 1 value, cerebral and cerebellar gray matter had longer T 1 's than that of white matter. Pathological lesions, such as tumor and/or infarct, had also longer T 1 values than these of normal tissue. The value of T 1 was thought to be applicable clinically except for some problems, such as measuring T 1 value of large extent. No side effects were found during and after examinations. (author)

  4. Role of MR imaging in the differentiation of benign and nonbenign intracranial meningiomas. The utility of contrast-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Matsuo, Michimasa

    1996-01-01

    The purpose of this study was to develop useful criteria for distinguishing nonbenign (atypical and malignant) primary intracranial meningiomas from their benign counterparts by using magnetic resonance imaging (MRI). To determine useful MRI findings for this purpose, 12 benign and five nonbenign meningiomas were retrospectively evaluated according to the following items: tumor signal intensity on plain T1-, T2- and proton density-weighted images, degree of perifocal edema on T2-weighted images, morphology of the tumor margin on contrast-enhanced T1-weighted images, presence of irregular nodule and/or mushrooming pattern on contrast-enhanced T1-weighted images, homogeneity of the tumor on contrast-enhanced T1-weighted images, and presence of marked skull destruction. Markedly irregular tumor margin, presence of irregular nodule and/or mushrooming pattern and markedly inhomogeneous enhancing pattern were significantly more frequent in nonbenign meningiomas. We defined these three MRI findings as nonbenign findings, and tried to categorize meningiomas by the number of nonbenign findings. It was found that 10 meningiomas with no or one nonbenign finding were benign lesions, of four meningiomas with two nonbenign findings two were benign lesions and two were nonbenign lesions, and three meningiomas with three nonbenign findings were nonbenign lesions. The two benign meningiomas with two nonbenign findings were accompanied by increased mitotic activity or brain invasion. Contrast-enhanced T1-weighted images were considered very useful in distinguishing benign and nonbenign meningiomas. (author)

  5. On weighted spaces without a fundamental sequence of bounded sets

    International Nuclear Information System (INIS)

    Olaleru, J.O.

    2001-09-01

    The problem of countably quasibarrelledness of weighted spaces of continuous functions, of which there are no results in the general setting of weighted spaces, is tackled in this paper. This leads to the study of quasibarrelledness of weighted spaces which, unlike that of Ernst and Schnettler, though with a similar approach, we drop the assumption that the weighted space has a fundamental sequence of bounded sets. The study of countably quasibarrelledness of weighted spaces naturally leads to definite results on the weighted (DF)-spaces for those weighted spaces with a fundamental sequence of bounded sets. (author)

  6. Dynamics of Mixed Dark Energy Domination in Teleparallel Gravity and Phase-Space Analysis

    Directory of Open Access Journals (Sweden)

    Emre Dil

    2015-01-01

    Full Text Available We consider a novel dark energy model to investigate whether it will provide an expanding universe phase. Here we propose a mixed dark energy domination which is constituted by tachyon, quintessence, and phantom scalar fields nonminimally coupled to gravity, in the absence of background dark matter and baryonic matter, in the framework of teleparallel gravity. We perform the phase-space analysis of the model by numerical methods and find the late-time accelerated attractor solutions implying the acceleration phase of universe.

  7. Diagnosis of nerve root compromise of the lumbar spine: Evaluation of the performance of three-dimensional isotropic T2-weighted turbo spin-echo SPACE sequence at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Jin Kyeong; Jee, Won Hee; Jung, Joon Yong; Jang, Jin Hee; Kim, Jin Sung; Kim, Young Hoon; Ha, Kee Yong [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-01-15

    To explore the performance of three-dimensional (3D) isotropic T2-weighted turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip angle evolution (SPACE) sequence on a 3T system, for the evaluation of nerve root compromise by disc herniation or stenosis from central to extraforaminal location of the lumbar spine, when used alone or in combination with conventional two-dimensional (2D) TSE sequence. Thirty-seven patients who had undergone 3T spine MRI including 2D and 3D sequences, and had subsequent spine surgery for nerve root compromise at a total of 39 nerve levels, were analyzed. A total of 78 nerve roots (48 symptomatic and 30 asymptomatic sites) were graded (0 to 3) using different MRI sets of 2D, 3D (axial plus sagittal), 3D (all planes), and combination of 2D and 3D sequences, with respect to the nerve root compromise caused by posterior disc herniations, lateral recess stenoses, neural foraminal stenoses, or extraforaminal disc herniations; grading was done independently by two readers. Diagnostic performance was compared between different imaging sets using the receiver operating characteristics (ROC) curve analysis. There were no statistically significant differences (p = 0.203 to > 0.999) in the ROC curve area between the imaging sets for both readers 1 and 2, except for combined 2D and 3D (0.843) vs. 2D (0.802) for reader 1 (p = 0.035), and combined 2D and 3D (0.820) vs. 3D including all planes (0.765) for reader 2 (p = 0.049). The performance of 3D isotropic T2-weighted TSE sequence of the lumbar spine, whether axial plus sagittal images, or all planes of images, was not significantly different from that of 2D TSE sequences, for the evaluation of nerve root compromise of the lumbar spine. Combining 2D and 3D might possibly improve the diagnostic accuracy compared with either one.

  8. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    International Nuclear Information System (INIS)

    Mürtz, P.; Kaschner, M.; Lakghomi, A.; Gieseke, J.; Willinek, W.A.; Schild, H.H.; Thomas, D.

    2015-01-01

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus

  9. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mürtz, P., E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Kaschner, M., E-mail: Marius.Kaschner@med.uni-duesseldorf.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Lakghomi, A., E-mail: Asadeh.Lakghomi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Gieseke, J., E-mail: juergen.gieseke@ukb.uni-bonn.de [Philips Healthcare, Lübeckertordamm 5, 20099 Hamburg (Germany); Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Willinek, W.A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Schild, H.H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Thomas, D., E-mail: daniel.thomas@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany)

    2015-04-15

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus.

  10. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    Science.gov (United States)

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  11. Ultrashort Echo Time Magnetic Resonance Imaging of the Lung Using a High-Relaxivity T1 Blood-Pool Contrast Agent

    Directory of Open Access Journals (Sweden)

    Joris Tchouala Nofiele

    2014-10-01

    Full Text Available The lung remains one of the most challenging organs to image using magnetic resonance imaging (MRI due to intrinsic rapid signal decay. However, unlike conventional modalities such as computed tomography, MRI does not involve radiation and can provide functional and morphologic information on a regional basis. Here we demonstrate proof of concept for a new MRI approach to achieve substantial gains in a signal to noise ratio (SNR in the lung parenchyma: contrast-enhanced ultrashort echo time (UTE imaging following intravenous injection of a high-relaxivity blood-pool manganese porphyrin T1 contrast agent. The new contrast agent increased relative enhancement of the lung parenchyma by over 10-fold compared to gadolinium diethylene triamine pentaacetic acid (Gd-DTPA, and the use of UTE boosted the SNR by a factor of 4 over conventional T1-weighted gradient echo acquisitions. The new agent also maintains steady enhancement over at least 60 minutes, thus providing a long time window for obtaining high-resolution, high-quality images and the ability to measure a number of physiologic parameters.

  12. Kiss High Blood Pressure Goodbye: The Relationship between Dark Chocolate and Hypertension

    Science.gov (United States)

    Nordmoe, Eric D.

    2008-01-01

    This article reports on a delicious finding from a recent study claiming a causal link between dark chocolate consumption and blood pressure reductions. In the article, I provide ideas for using this study to whet student appetites for a discussion of statistical ideas, including experimental design, measurement error and inference methods.

  13. Blood profile of proteins and steroid hormones predicts weight change after weight loss with interactions of dietary protein level and glycemic index.

    Directory of Open Access Journals (Sweden)

    Ping Wang

    2011-02-01

    Full Text Available Weight regain after weight loss is common. In the Diogenes dietary intervention study, high protein and low glycemic index (GI diet improved weight maintenance.To identify blood predictors for weight change after weight loss following the dietary intervention within the Diogenes study.Blood samples were collected at baseline and after 8-week low caloric diet-induced weight loss from 48 women who continued to lose weight and 48 women who regained weight during subsequent 6-month dietary intervention period with 4 diets varying in protein and GI levels. Thirty-one proteins and 3 steroid hormones were measured.Angiotensin I converting enzyme (ACE was the most important predictor. Its greater reduction during the 8-week weight loss was related to continued weight loss during the subsequent 6 months, identified by both Logistic Regression and Random Forests analyses. The prediction power of ACE was influenced by immunoproteins, particularly fibrinogen. Leptin, luteinizing hormone and some immunoproteins showed interactions with dietary protein level, while interleukin 8 showed interaction with GI level on the prediction of weight maintenance. A predictor panel of 15 variables enabled an optimal classification by Random Forests with an error rate of 24±1%. A logistic regression model with independent variables from 9 blood analytes had a prediction accuracy of 92%.A selected panel of blood proteins/steroids can predict the weight change after weight loss. ACE may play an important role in weight maintenance. The interactions of blood factors with dietary components are important for personalized dietary advice after weight loss.ClinicalTrials.gov NCT00390637.

  14. Clinical characteristics in normal healthy adults with microbleeds on echo-planar gradient-echo T2*-weighted MRI

    International Nuclear Information System (INIS)

    Takahashi, Wakoh; Ide, Michiru; Ohnuki, Tomohide; Takagi, Shigeharu; Shinohara, Yukito

    2004-01-01

    The gradient-echo T 2 * -weighted sequence in magnetic resonance imaging is known to be useful for detecting microbleeds (MBs) in patients with intracranial hemorrhage or lacunar stroke. We investigated the characteristics of apparently healthy adults with MBs but without stroke, employing echo-planar gradient-echo T 2 * -weighted MRI. The subjects were recruited from among 3,537 participants who underwent brain check-ups at the HIMEDIC Imaging Center. Of the 3,537 participants, 3,296 (mean age, 55±11 years) without any history of cerebrovascular disease or apparent focal neurological manifestations were selected for the present study. MBs on echo-planar gradient-echo T 2 * -weighted MRI were observed in 74 (2.2%) of the 3,296 subjects. Of a total of 133 lesions found in these 74 persons, 31 were located in the basal ganglia or cortico-subcortical regions. Thirty were in the deep white matter, 19 in the thalamus, 16 in the cerebellum, and 6 in the brain stem. The subjects with MBs were significantly older than the subjects without MBs, and the mean values for their systolic and diastolic blood pressures were higher than those in the subjects without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs, as compared with those without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs of the basal ganglia or thalamus than in those with MBs in other regions. MBs on echo-planar gradient-echo T 2 * -weighted MRI were thus relatively rare in apparently healthy adults. However, MBs in the basal ganglia or thalamus are suggested to be closely related to intracerebral microangiopathy. Persons with MBs in such regions should therefore be carefully checked for cerebrovascular risk

  15. T2 image contrast evaluation using three dimension sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE)

    International Nuclear Information System (INIS)

    Yamazaki, Ryo; Hiura, Yukikazu; Tsuji, Akio; Nishiki, Shigeo; Uchikoshi, Masato

    2011-01-01

    Sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE) sequence enables one to decrease specific absorption rate (SAR) by using variable flip angle refocusing pulse. Therefore, it is expected that the contrast obtained with 3D-SPACE sequences is different from that of spin echo (SE) images and turbo spin echo (TSE) images. The purpose of this study was to evaluate the characteristics of the signal intensity and central nervous system (CNS) image contrast in T 2 weighted 3D-SPACE. Using 3 different sequences (SE, 3D-TSE and 3D-SPACE) with repetition time (TR)/ echo time (TE)=3500/70, 90 and 115 ms, we obtained T 2 weighted magnetic resonance (MR) images of inhouse phantom and five healthy volunteers' brain. Signal intensity of the phantom which contains various T 1 and T 2 value was evaluated. Tissue contrasts of white/gray matter, cerebrospinal fluid (CSF)/subcutaneous fat and gray matter/subcutaneous fat were evaluated for a clinical image study. The phantom study showed that signal intensity in 3D-SPACE significantly decreased under a T 1 value of 250 ms. It was markedly decreased in comparison to other sequences, as effective echo time (TE) was extended. White/gray matter contrast of 3D-SPACE was the highest in all sequences. On the other hand, CSF/fat and gray matter/fat contrast of 3D-SPACE was higher than TSE but lower than SE. CNS image contrasts of 3D-SPACE were comparable to that of SE. Signal intensity had decreased in the range where T 1 and T 2 values were extremely short. (author)

  16. High signal in the adenohypophysis on T1-weighted images presumably due to manganese deposits in patients on long-term parenteral nutrition

    International Nuclear Information System (INIS)

    Dietemann, J.L.; Diniz, R.L.F.C.; Reis, M. Jr.; Neugroschl, C.; Soehsten, S. von; Reimund, J.M.; Baumann, R.; Warter, J.M.

    1998-01-01

    Hypermanganesaemia is reported in patients on long-term parenteral nutrition. Deposition of manganese, giving high signal on T1-weighted images, may involve the basal ganglia. MRI in nine patients (mean age 51 years, range 31-75 years) on long-term parenteral nutrition (mean duration 30 months, range 6-126 months), demonstrated high signal in the anterior pituitary gland on T1-weighted sagittal and coronal images. The gland appeared normal on T2-weighted images. Signal intensity in the basal ganglia on T1-weighted images was increased in all patients. Endocrine assessment showed no significant abnormality. Neurological examination showed a mild parkinsonian movement disorder in one patient. Hypermanganaesemia was present in all nine (1.3-2.8 μmol/l, mean 1.87 μmol/l). The high signal in the anterior pituitary gland was probably related to deposition of paramagnetic substances, especially manganese. (orig.)

  17. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  18. Integral type operators from normal weighted Bloch spaces to QT,S spaces

    Directory of Open Access Journals (Sweden)

    Yongyi GU

    2016-08-01

    Full Text Available Operator theory is an important research content of the analytic function space theory. The discussion of simultaneous operator and function space is an effective way to study operator and function space. Assuming that  is an analytic self map on the unit disk Δ, and the normal weighted bloch space μ-B is a Banach space on the unit disk Δ, defining a composition operator C∶C(f=f on μ-B for all f∈μ-B, integral type operator JhC and CJh are generalized by integral operator and composition operator. The boundeness and compactness of the integral type operator JhC acting from normal weighted Bloch spaces to QT,S spaces are discussed, as well as the boundeness of the integral type operators CJh acting from normal weighted Bloch spaces to QT,S spaces. The related sufficient and necessary conditions are given.

  19. High signal in the adenohypophysis on T1-weighted images presumably due to manganese deposits in patients on long-term parenteral nutrition

    Energy Technology Data Exchange (ETDEWEB)

    Dietemann, J.L.; Diniz, R.L.F.C.; Reis, M. Jr.; Neugroschl, C.; Soehsten, S. von [Department of Radiology 2, University Hospital of Strasbourg (France); Reimund, J.M.; Baumann, R. [Department of Hepatogastroenterology, University Hospital of Strasbourg (France); Warter, J.M. [Department of Neurology, University Hospital of Strasbourg (France)

    1998-12-01

    Hypermanganesaemia is reported in patients on long-term parenteral nutrition. Deposition of manganese, giving high signal on T1-weighted images, may involve the basal ganglia. MRI in nine patients (mean age 51 years, range 31-75 years) on long-term parenteral nutrition (mean duration 30 months, range 6-126 months), demonstrated high signal in the anterior pituitary gland on T1-weighted sagittal and coronal images. The gland appeared normal on T2-weighted images. Signal intensity in the basal ganglia on T1-weighted images was increased in all patients. Endocrine assessment showed no significant abnormality. Neurological examination showed a mild parkinsonian movement disorder in one patient. Hypermanganaesemia was present in all nine (1.3-2.8 {mu}mol/l, mean 1.87 {mu}mol/l). The high signal in the anterior pituitary gland was probably related to deposition of paramagnetic substances, especially manganese. (orig.) With 2 figs., 1 tab., 17 refs.

  20. Giving pandas ROOT to chew on: experiences with the XENON1T Dark Matter experiment

    Science.gov (United States)

    Remenska, D.; Tunnell, C.; Aalbers, J.; Verhoeven, S.; Maassen, J.; Templon, J.

    2017-10-01

    In preparation for the XENON1T Dark Matter data acquisition, we have prototyped and implemented a new computing model. The XENON signal and data processing software is developed fully in Python 3, and makes extensive use of generic scientific data analysis libraries, such as the SciPy stack. A certain tension between modern “Big Data” solutions and existing HEP frameworks is typically experienced in smaller particle physics experiments. ROOT is still the “standard” data format in our field, defined by large experiments (ATLAS, CMS). To ease the transition, our computing model caters to both analysis paradigms, leaving the choice of using ROOT-specific C++ libraries, or alternatively, Python and its data analytics tools, as a front-end choice of developing physics algorithms. We present our path on harmonizing these two ecosystems, which allowed us to use off-the-shelf software libraries (e.g., NumPy, SciPy, scikit-learn, matplotlib) and lower the cost of development and maintenance. To analyse the data, our software allows researchers to easily create “mini-trees” small, tabular ROOT structures for Python analysis, which can be read directly into pandas DataFrame structures. One of our goals was making ROOT available as a cross-platform binary for an easy installation from the Anaconda Cloud (without going through the “dependency hell”). In addition to helping us discover dark matter interactions, lowering this barrier helps shift the particle physics toward non-domain-specific code.

  1. Local dark matter and dark energy as estimated on a scale of ~1 Mpc in a self-consistent way

    Science.gov (United States)

    Chernin, A. D.; Teerikorpi, P.; Valtonen, M. J.; Dolgachev, V. P.; Domozhilova, L. M.; Byrd, G. G.

    2009-12-01

    Context: Dark energy was first detected from large distances on gigaparsec scales. If it is vacuum energy (or Einstein's Λ), it should also exist in very local space. Here we discuss its measurement on megaparsec scales of the Local Group. Aims: We combine the modified Kahn-Woltjer method for the Milky Way-M 31 binary and the HST observations of the expansion flow around the Local Group in order to study in a self-consistent way and simultaneously the local density of dark energy and the dark matter mass contained within the Local Group. Methods: A theoretical model is used that accounts for the dynamical effects of dark energy on a scale of ~1 Mpc. Results: The local dark energy density is put into the range 0.8-3.7ρv (ρv is the globally measured density), and the Local Group mass lies within 3.1-5.8×1012 M⊙. The lower limit of the local dark energy density, about 4/5× the global value, is determined by the natural binding condition for the group binary and the maximal zero-gravity radius. The near coincidence of two values measured with independent methods on scales differing by ~1000 times is remarkable. The mass ~4×1012 M⊙ and the local dark energy density ~ρv are also consistent with the expansion flow close to the Local Group, within the standard cosmological model. Conclusions: One should take into account the dark energy in dynamical mass estimation methods for galaxy groups, including the virial theorem. Our analysis gives new strong evidence in favor of Einstein's idea of the universal antigravity described by the cosmological constant.

  2. Dirac dark matter and b →s ℓ+ℓ- with U(1) gauge symmetry

    Science.gov (United States)

    Celis, Alejandro; Feng, Wan-Zhe; Vollmann, Martin

    2017-02-01

    We revisit the possibility of a Dirac fermion dark matter candidate in the light of current b →s ℓ+ℓ- anomalies by investigating a minimal extension of the Standard Model with a horizontal U(1 ) ' local symmetry. Dark matter stability is protected by a remnant Z2 symmetry arising after spontaneous symmetry breaking of U(1 ) '. The associated Z' gauge boson can accommodate current hints of new physics in b →s ℓ+ℓ- decays, and acts as a vector portal between dark matter and the visible sector. We find that the model is severely constrained by a combination of precision measurements at flavor factories, LHC searches for dilepton resonances, as well as direct and indirect dark matter searches. Despite this, viable regions of the parameter space accommodating the observed dark matter relic abundance and the b →s ℓ+ℓ-anomalies still persist for dark matter and Z ' masses in the TeV range.

  3. Multidimensional Space-Time Methodology for Development of Planetary and Space Sciences, S-T Data Management and S-T Computational Tomography

    Science.gov (United States)

    Andonov, Zdravko

    This R&D represent innovative multidimensional 6D-N(6n)D Space-Time (S-T) Methodology, 6D-6nD Coordinate Systems, 6D Equations, new 6D strategy and technology for development of Planetary Space Sciences, S-T Data Management and S-T Computational To-mography. . . The Methodology is actual for brain new RS Microwaves' Satellites and Compu-tational Tomography Systems development, aimed to defense sustainable Earth, Moon, & Sun System evolution. Especially, extremely important are innovations for monitoring and protec-tion of strategic threelateral system H-OH-H2O Hydrogen, Hydroxyl and Water), correspond-ing to RS VHRS (Very High Resolution Systems) of 1.420-1.657-22.089GHz microwaves. . . One of the Greatest Paradox and Challenge of World Science is the "transformation" of J. L. Lagrange 4D Space-Time (S-T) System to H. Minkovski 4D S-T System (O-X,Y,Z,icT) for Einstein's "Theory of Relativity". As a global result: -In contemporary Advanced Space Sciences there is not real adequate 4D-6D Space-Time Coordinate System and 6D Advanced Cosmos Strategy & Methodology for Multidimensional and Multitemporal Space-Time Data Management and Tomography. . . That's one of the top actual S-T Problems. Simple and optimal nD S-T Methodology discovery is extremely important for all Universities' Space Sci-ences' Education Programs, for advances in space research and especially -for all young Space Scientists R&D!... The top ten 21-Century Challenges ahead of Planetary and Space Sciences, Space Data Management and Computational Space Tomography, important for successfully de-velopment of Young Scientist Generations, are following: 1. R&D of W. R. Hamilton General Idea for transformation all Space Sciences to Time Sciences, beginning with 6D Eukonal for 6D anisotropic mediums & velocities. Development of IERS Earth & Space Systems (VLBI; LLR; GPS; SLR; DORIS Etc.) for Planetary-Space Data Management & Computational Planetary & Space Tomography. 2. R&D of S. W. Hawking Paradigm for 2D

  4. Schur spaces and weighted spaces of type H

    African Journals Online (AJOL)

    We extend some results related to composition operators on Hv(G) to arbitrary linear operators on Hv0 (G) and Hv(G). We also give examples of rank-one operators on Hv(G) which cannot be approximated by composition operators. Keywords: Weighted Banach spaces of holomorphic functions, Schur spaces, weakly ...

  5. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  6. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  7. Quantitative analysis of hyperintensity rim sign surrounding MS plaque on T1 weighted images. Comparison with lacunar infarction

    International Nuclear Information System (INIS)

    Komura, Shinji; Ozaki, Yutaka

    2008-01-01

    This study evaluated the incidence of MR findings showing a hyperintensity rim surrounding multiple sclerosis (MS) plaque on T1-weighted images using image analysis software. We also evaluate the efficacy of this MR finding for differentiating between MS and lacunar infarction. We reviewed T1-weighted images in clinically diagnosed MS patients who underwent MR imaging between February 2006 and July 2007. Two hundred and thirty-nine nodular low signal intensities over 5 mm in minimal diameter were observed in 39 MS patients. To compare the incidence of MR findings, we also reviewed T1-weighted images in randomly selected lacunar infarction patients who underwent MR imaging during the same period. There were 51 nodular low signal intensities over 5 mm in shortest diameter in 34 lacunar infarction patients. After standardization of MR images, we calculated each signal intensity at the plaque margin (M.I.) and surrounding white matter (Wh.I.) using plot-profile analysis. We judged that hyperintensity rim sign was positive when the M.I/Wh.I. ratio was over 1.05. Among 239 T1 low intensity plaques in 39 MS patients, hyperintensity rim sign was positive for 81 (33.9%) plaques in 21 (53.8%) patients. Among 51 T1 low intensity lesions in 34 lacunar infarction patients, hyperintensity rim sign was positive for only one lesion in one patient. There were significant differences in the incidence of hyperintensity rim sign between the two patients groups (p<0.0001). On quantitative analysis using imaging standardization and plot-profile analysis, hyperintensity rim sign was observed in one-third of T1 low intensity MS plaques. This finding seems to be useful to differentiate multiple sclerosis from lacunar infarction. (author)

  8. Seroprevalence of human T-cell lymphotropic virus-1/2 in blood donors in northern pakistan: implication for blood donor screening

    International Nuclear Information System (INIS)

    Niazi, S.K.

    2015-01-01

    To determine the seroprevalence of Human T-cell Lymphotropic Virus-1/2 (HTLV-1/2) in blood donors in Northern Pakistan. Study Design: Descriptive study. Place and Duration of Study: Armed Forces Institute of Transfusion, Rawalpindi, from July to August 2013. Methodology:A total of 2100 blood donors were screened for anti-HTLV-1/2 antibodies during the study period, in a pool of six, on a highly sensitive, Chemiluminiscent Microparticle Immunoassay (CMIA) based system. The screening test reactive donors were recalled, counseled and interviewed, and a fresh sample was obtained for confirmatory testing. Confirmation was performed using additional immunoassays including Line Immunoassay (LIA); with additional testing for HTLV-1 pvDNAPCR. Frequency and percentages were determined. Results: Four donors (0.19%) were repeatedly screening test-reactive and were subsequently confirmed to be HTLV-1 infected by line immunoassay and HTLV-1 pvDNAPCR. All four donors were male with mean age of 27 ± 6.27 years. Two (50%) of the positive donors gave history of Multiple Sexual Partners (MSP). Conclusion: HTLV-1 seroprevalence in Northern Pakistan blood donors was determined to be 0.19%. Large scale studies, including the cost effectiveness of screening blood donations for anti-HTLV-1/2 in Pakistan, are recommended. (author)

  9. Two-dimensional T2 distribution mapping in rock core plugs with optimal k-space sampling.

    Science.gov (United States)

    Xiao, Dan; Balcom, Bruce J

    2012-07-01

    Spin-echo single point imaging has been employed for 1D T(2) distribution mapping, but a simple extension to 2D is challenging since the time increase is n fold, where n is the number of pixels in the second dimension. Nevertheless 2D T(2) mapping in fluid saturated rock core plugs is highly desirable because the bedding plane structure in rocks often results in different pore properties within the sample. The acquisition time can be improved by undersampling k-space. The cylindrical shape of rock core plugs yields well defined intensity distributions in k-space that may be efficiently determined by new k-space sampling patterns that are developed in this work. These patterns acquire 22.2% and 11.7% of the k-space data points. Companion density images may be employed, in a keyhole imaging sense, to improve image quality. T(2) weighted images are fit to extract T(2) distributions, pixel by pixel, employing an inverse Laplace transform. Images reconstructed with compressed sensing, with similar acceleration factors, are also presented. The results show that restricted k-space sampling, in this application, provides high quality results. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Disjoint hypercyclicity of weighted composition operators

    Indian Academy of Sciences (India)

    Hypercyclicity; supercyclicity; disjoint hypercyclicity; disjoint super- cyclicity; weighted composition operators; Hilbert space. 2010 Mathematics Subject Classification. 47A16, 47B33, 47B38. 1. Introduction. Let X be a topological vector space and T a bounded linear operator on X. The T-orbit of a vector x ∈ X is the set. O(x,T) ...

  11. Study on the mapping of dark matter clustering from real space to redshift space

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yi; Song, Yong-Seon, E-mail: yizheng@kasi.re.kr, E-mail: ysong@kasi.re.kr [Korea Astronomy and Space Science Institute, Daejeon 34055 (Korea, Republic of)

    2016-08-01

    The mapping of dark matter clustering from real space to redshift space introduces the anisotropic property to the measured density power spectrum in redshift space, known as the redshift space distortion effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to indefinite cross correlations between the density and velocity fields, and the Finger-of-God effect due to the randomness of the peculiar velocity field. Whilst the full higher order polynomials remain unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion directly using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the ''one-point' FoG term being independent of the separation vector between two different points, and 2) the ''correlated' FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the Gaussian FoG function with only one scale-independent free parameter works quite well, and that our new mapping formulation accurately reproduces the observed 2-dimensional density power spectrum in redshift space at the smallest scales by far, up to k ∼ 0.2 Mpc{sup -1}, considering the resolution of future experiments.

  12. Study on the mapping of dark matter clustering from real space to redshift space

    International Nuclear Information System (INIS)

    Zheng, Yi; Song, Yong-Seon

    2016-01-01

    The mapping of dark matter clustering from real space to redshift space introduces the anisotropic property to the measured density power spectrum in redshift space, known as the redshift space distortion effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to indefinite cross correlations between the density and velocity fields, and the Finger-of-God effect due to the randomness of the peculiar velocity field. Whilst the full higher order polynomials remain unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion directly using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the ''one-point' FoG term being independent of the separation vector between two different points, and 2) the ''correlated' FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the Gaussian FoG function with only one scale-independent free parameter works quite well, and that our new mapping formulation accurately reproduces the observed 2-dimensional density power spectrum in redshift space at the smallest scales by far, up to k ∼ 0.2 Mpc -1 , considering the resolution of future experiments.

  13. Methods of fetal MR: beyond T2-weighted imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Stuhr, Fritz; Lindner, Christian; Prayer, Daniela

    2006-01-01

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body

  14. Methods of fetal MR: beyond T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Stuhr, Fritz [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Lindner, Christian [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body.

  15. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI.

    Science.gov (United States)

    Drobnitzky, Matthias; Klose, Uwe

    2017-03-01

    Magnetization-prepared rapid gradient-echo (MPRAGE) sequences are commonly employed for T1-weighted structural brain imaging. Following a contrast preparation radiofrequency (RF) pulse, the data acquisition proceeds under nonequilibrium conditions of the relaxing longitudinal magnetization. Variation of the flip angle can be used to maximize total available signal. Simulated annealing or greedy algorithms have so far been published to numerically solve this problem, with signal-to-noise ratios optimized for clinical imaging scenarios by adhering to a predefined shape of the signal evolution. We propose an unconstrained optimization of the MPRAGE experiment that employs techniques from resource allocation theory. A new dynamic programming solution is introduced that yields closed-form expressions for optimal flip angle variation. Flip angle series are proposed that maximize total transverse magnetization (Mxy) for a range of physiologic T1 values. A 3D MPRAGE sequence is modified to allow for a controlled variation of the excitation angle. Experiments employing a T1 contrast phantom are performed at 3T. 1D acquisitions without phase encoding permit measurement of the temporal development of Mxy. Image mean signal and standard deviation for reference flip angle trains are compared in 2D measurements. Signal profiles at sharp phantom edges are acquired to access image blurring related to nonuniform Mxy development. A novel closed-form expression for flip angle variation is found that constitutes the optimal policy to reach maximum total signal. It numerically equals previously published results of other authors when evaluated under their simplifying assumptions. Longitudinal magnetization (Mz) is exhaustively used without causing abrupt changes in the measured MR signal, which is a prerequisite for artifact free images. Phantom experiments at 3T verify the expected benefit for total accumulated k-space signal when compared with published flip angle series. Describing

  16. Spectral analysis of difference and differential operators in weighted spaces

    International Nuclear Information System (INIS)

    Bichegkuev, M S

    2013-01-01

    This paper is concerned with describing the spectrum of the difference operator K:l α p (Z,X)→l α p (Z......athscrKx)(n)=Bx(n−1),  n∈Z,  x∈l α p (Z,X), with a constant operator coefficient B, which is a bounded linear operator in a Banach space X. It is assumed that K acts in the weighted space l α p (Z,X), 1≤p≤∞, of two-sided sequences of vectors from X. The main results are obtained in terms of the spectrum σ(B) of the operator coefficient B and properties of the weight function. Applications to the study of the spectrum of a differential operator with an unbounded operator coefficient (the generator of a strongly continuous semigroup of operators) in weighted function spaces are given. Bibliography: 23 titles

  17. Evaluation of multimodal segmentation based on 3D T1-, T2- and FLAIR-weighted images - the difficulty of choosing.

    Science.gov (United States)

    Lindig, Tobias; Kotikalapudi, Raviteja; Schweikardt, Daniel; Martin, Pascal; Bender, Friedemann; Klose, Uwe; Ernemann, Ulrike; Focke, Niels K; Bender, Benjamin

    2018-04-15

    Voxel-based morphometry is still mainly based on T1-weighted MRI scans. Misclassification of vessels and dura mater as gray matter has been previously reported. Goal of the present work was to evaluate the effect of multimodal segmentation methods available in SPM12, and their influence on identification of age related atrophy and lesion detection in epilepsy patients. 3D T1-, T2- and FLAIR-images of 77 healthy adults (mean age 35.8 years, 19-66 years, 45 females), 7 patients with malformation of cortical development (MCD) (mean age 28.1 years,19-40 years, 3 females), and 5 patients with left hippocampal sclerosis (LHS) (mean age 49.0 years, 25-67 years, 3 females) from a 3T scanner were evaluated. Segmentation based on T1-only, T1+T2, T1+FLAIR, T2+FLAIR, and T1+T2+FLAIR were compared in the healthy subjects. Clinical VBM results based on the different segmentation approaches for MCD and for LHS were compared. T1-only segmentation overestimated total intracranial volume by about 80ml compared to the other segmentation methods. This was due to misclassification of dura mater and vessels as GM and CSF. Significant differences were found for several anatomical regions: the occipital lobe, the basal ganglia/thalamus, the pre- and postcentral gyrus, the cerebellum, and the brainstem. None of the segmentation methods yielded completely satisfying results for the basal ganglia/thalamus and the brainstem. The best correlation with age could be found for the multimodal T1+T2+FLAIR segmentation. Highest T-scores for identification of LHS were found for T1+T2 segmentation, while highest T-scores for MCD were dependent on lesion and anatomical location. Multimodal segmentation is superior to T1-only segmentation and reduces the misclassification of dura mater and vessels as GM and CSF. Depending on the anatomical region and the pathology of interest (atrophy, lesion detection, etc.), different combinations of T1, T2 and FLAIR yield optimal results. Copyright © 2017 Elsevier

  18. Mn-DPDP enhanced T1-weighted magnetic resonance cholangiography: usefulness in the diagnosis and roadmap for the treatment of intrahepatic choIedochoIithiasis

    International Nuclear Information System (INIS)

    Park, Mi Suk; Kim, Ki Whang; Yu, Jeong Sik; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Kim, Kyoung Won; Kim, Tae Kyoung; Ha, Hyun Kwon

    2004-01-01

    To assess the preliminary findings of Mn-enhanced T1-weighted MR cholangiography for the evaluation of intrahepatic choledocholithiasis. Seven patients with recurrent pyogenic cholangitis underwent conventional heavily T2-weighted and manganese-enhanced T1-weighted MR cholangiography. For the former, the two reviewers focused on intrahepatic ductal dilatation, calculi, and stricture; and for the latter, ductal enhancement. In seven patients, 13 diseased segments were depicted and intrahepatic bile ductal dilatation was present in all 13 of these in all seven patients. Calculi were present in eight segments in six patients, and stricture in four segments in three patients. Of the 13 diseased segmental ducts, six were seen at manganese-enhanced imaging to be filled with contrast material, suggesting a functioning bile duct. Combined T2-weighted and mangafodipir trisodium-enhanced T1-weighted MR cholangiography provides both anatomic detail and functional detail of the biliary system. Combined MR cholangiography is useful for the evaluation of intrahepatic choledocholithiasis, demonstrating the stricture and function of the segmental ducts involved

  19. Redshift space clustering of galaxies and cold dark matter model

    Science.gov (United States)

    Bahcall, Neta A.; Cen, Renyue; Gramann, Mirt

    1993-01-01

    The distorting effect of peculiar velocities on the power speturm and correlation function of IRAS and optical galaxies is studied. The observed redshift space power spectra and correlation functions of IRAS and optical the galaxies over the entire range of scales are directly compared with the corresponding redshift space distributions using large-scale computer simulations of cold dark matter (CDM) models in order to study the distortion effect of peculiar velocities on the power spectrum and correlation function of the galaxies. It is found that the observed power spectrum of IRAS and optical galaxies is consistent with the spectrum of an Omega = 1 CDM model. The problems that such a model currently faces may be related more to the high value of Omega in the model than to the shape of the spectrum. A low-density CDM model is also investigated and found to be consistent with the data.

  20. Λ(t)CDM model as a unified origin of holographic and agegraphic dark energy models

    International Nuclear Information System (INIS)

    Chen Yun; Zhu Zonghong; Xu Lixin; Alcaniz, J.S.

    2011-01-01

    Motivated by the fact that any nonzero Λ can introduce a length scale or a time scale into Einstein's theory, r Λ =ct Λ =√(3/|Λ|). Conversely, any cosmological length scale or time scale can introduce a Λ(t), Λ(t)=3/r Λ 2 (t)=3/(c 2 t Λ 2 (t)). In this Letter, we investigate the time varying Λ(t) corresponding to the length scales, including the Hubble horizon, the particle horizon and the future event horizon, and the time scales, including the age of the universe and the conformal time. It is found out that, in this scenario, the Λ(t)CDM model can be taken as the unified origin of the holographic and agegraphic dark energy models with interaction between the matter and the dark energy, where the interacting term is determined by Q=-ρ . Λ . We place observational constraints on the Λ(t)CDM models originating from different cosmological length scales and time scales with the recently compiled 'Union2 compilation' which consists of 557 Type Ia supernovae (SNIa) covering a redshift range 0.015≤z≤1.4. In conclusion, an accelerating expansion universe can be derived in the cases taking the Hubble horizon, the future event horizon, the age of the universe and the conformal time as the length scale or the time scale.

  1. Search for dark matter in association with a $\\mathrm{t\\overline{t}}$ pair at $\\sqrt{s}=13~\\mathrm{TeV}$ in the dilepton channel with 2016 data

    CERN Document Server

    CMS Collaboration

    2018-01-01

    A search is performed for dark matter produced in association with $\\mathrm{t\\overline{t}}$ pairs in data from proton-proton collisions at a center-of-mass energy of 13 TeV at the LHC. The data corresponds to $35.9~\\mathrm{fb}^{-1}$ collected with the CMS detector in 2016. The analysis looks for an excess of events with large imbalance in transverse momentum and a top quark pair decaying in the dileptonic mode. The results are interpreted in the context of simplified models of dark matter production. Assuming unitary coupling values to standard model (SM) particles $g_{\\text{q}}$, and dark matter (DM) particles $g_{\\chi}$, and DM mass $m_{\\chi} = 1~\\mathrm{GeV}$, the observed (expected) $95\\%$ CL exclusions for a scalar mediator are $m_{\\phi} < 74\\:(99)~\\mathrm{GeV}$. The $95\\%$ CL exclusion expected for a pseudoscalar mediator is $m_{a} < 50~\\mathrm{GeV}$, while none is observed.

  2. Accounting for the Confound of Meninges in Segmenting Entorhinal and Perirhinal Cortices in T1-Weighted MRI.

    Science.gov (United States)

    Xie, Long; Wisse, Laura E M; Das, Sandhitsu R; Wang, Hongzhi; Wolk, David A; Manjón, Jose V; Yushkevich, Paul A

    2016-10-01

    Quantification of medial temporal lobe (MTL) cortices, including entorhinal cortex (ERC) and perirhinal cortex (PRC), from in vivo MRI is desirable for studying the human memory system as well as in early diagnosis and monitoring of Alzheimer's disease. However, ERC and PRC are commonly over-segmented in T1-weighted (T1w) MRI because of the adjacent meninges that have similar intensity to gray matter in T1 contrast. This introduces errors in the quantification and could potentially confound imaging studies of ERC/PRC. In this paper, we propose to segment MTL cortices along with the adjacent meninges in T1w MRI using an established multi-atlas segmentation framework together with super-resolution technique. Experimental results comparing the proposed pipeline with existing pipelines support the notion that a large portion of meninges is segmented as gray matter by existing algorithms but not by our algorithm. Cross-validation experiments demonstrate promising segmentation accuracy. Further, agreement between the volume and thickness measures from the proposed pipeline and those from the manual segmentations increase dramatically as a result of accounting for the confound of meninges. Evaluated in the context of group discrimination between patients with amnestic mild cognitive impairment and normal controls, the proposed pipeline generates more biologically plausible results and improves the statistical power in discriminating groups in absolute terms comparing to other techniques using T1w MRI. Although the performance of the proposed pipeline is inferior to that using T2-weighted MRI, which is optimized to image MTL sub-structures, the proposed pipeline could still provide important utilities in analyzing many existing large datasets that only have T1w MRI available.

  3. Make dark matter charged again

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, Prateek; Cyr-Racine, Francis-Yan; Randall, Lisa; Scholtz, Jakub, E-mail: prateekagrawal@fas.harvard.edu, E-mail: fcyrraci@physics.harvard.edu, E-mail: randall@physics.harvard.edu, E-mail: jscholtz@physics.harvard.edu [Department of Physics, Harvard University, Cambridge, MA 02138 (United States)

    2017-05-01

    We revisit constraints on dark matter that is charged under a U(1) gauge group in the dark sector, decoupled from Standard Model forces. We find that the strongest constraints in the literature are subject to a number of mitigating factors. For instance, the naive dark matter thermalization timescale in halos is corrected by saturation effects that slow down isotropization for modest ellipticities. The weakened bounds uncover interesting parameter space, making models with weak-scale charged dark matter viable, even with electromagnetic strength interaction. This also leads to the intriguing possibility that dark matter self-interactions within small dwarf galaxies are extremely large, a relatively unexplored regime in current simulations. Such strong interactions suppress heat transfer over scales larger than the dark matter mean free path, inducing a dynamical cutoff length scale above which the system appears to have only feeble interactions. These effects must be taken into account to assess the viability of darkly-charged dark matter. Future analyses and measurements should probe a promising region of parameter space for this model.

  4. Effect of ground cinnamon on postprandial blood glucose concentration in normal-weight and obese adults.

    Science.gov (United States)

    Magistrelli, Ashley; Chezem, Jo Carol

    2012-11-01

    In healthy normal-weight adults, cinnamon reduces blood glucose concentration and enhances insulin sensitivity. Insulin resistance, resulting in increased fasting and postprandial blood glucose and insulin levels, is commonly observed in obese individuals. The objective of the study was to compare declines in postprandial glycemic response in normal-weight and obese subjects with ingestion of 6 g ground cinnamon. In a crossover study, subjects consumed 50 g available carbohydrate in instant farina cereal, served plain or with 6 g ground cinnamon. Blood glucose concentration, the main outcome measure, was assessed at minutes 0, 15, 30, 45, 60, 90, and 120. Repeated-measures analysis of variance evaluated the effects of body mass index (BMI) group, dietary condition, and time on blood glucose. Paired t-test assessed blood glucose at individual time points and glucose area under the curve (AUC) between dietary conditions. Thirty subjects between the ages of 18 and 30 years, 15 with BMIs between 18.5 and 24.9 and 15 with BMIs of 30.0 or more, completed the study. There was no significant difference in blood glucose between the two BMI groups at any time point. However, in a combined analysis of all subjects, the addition of cinnamon to the cereal significantly reduced 120-minute glucose AUC (P=0.008) and blood glucose at 15 (P=0.001), 30 (Pblood glucose was significantly higher with cinnamon consumption (Pglucose response in normal weight and obese adults. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  5. Differentiating benign and malignant breast lesions with T2*-weighted first pass perfusion imaging

    International Nuclear Information System (INIS)

    Kvistad, K.A.; Smenes, E.; Haraldseth, O.; Lundgren, S.; Fjoesne, H.E.; Smethurst, H.B.

    1999-01-01

    Purpose: Invasive breast carcinomas and fibroadenomas are often difficult to differentiate in dynamic contrast-enhanced T1-weighted MR imaging of the breast, because both tumors can enhance strongly after contrast injection. The purpose of this study was to evaluate whether the addition of T2*-weighted first pass perfusion imaging can increase the differentiation of malignant from benign lesions. Material and Methods: Nine patients with invasive carcinomas and 10 patients with contrast enhancing fibroadenomas were examined by a dynamic contrast-enhanced T1-weighted 3D sequence immediately followed by a single slice T2*-weighted first pass perfusion sequence positioned in the contrast-enhancing lesion. Results: The carcinomas and the fibroadenomas were impossible to differentiate based on the contrast enhancement characteristics in the T1-weighted sequence. The signal loss in the T2*-weighted perfusion sequence was significantly stronger in the carcinomas than in the fibroadenomas (p=0.0004). Conclusion: Addition of a T2*-weighted first pass perfusion sequence with a high temporal resolution can probably increase the differentiation of fibroadenomas from invasive carcinomas in contrast-enhanced MR imaging of the breast. (orig.)

  6. Relaxivity of Ferumoxytol at 1.5 T and 3.0 T.

    Science.gov (United States)

    Knobloch, Gesine; Colgan, Timothy; Wiens, Curtis N; Wang, Xiaoke; Schubert, Tilman; Hernando, Diego; Sharma, Samir D; Reeder, Scott B

    2018-05-01

    The aim of this study was to determine the relaxation properties of ferumoxytol, an off-label alternative to gadolinium-based contrast agents, under physiological conditions at 1.5 T and 3.0 T. Ferumoxytol was diluted in gradually increasing concentrations (0.26-4.2 mM) in saline, human plasma, and human whole blood. Magnetic resonance relaxometry was performed at 37°C at 1.5 T and 3.0 T. Longitudinal and transverse relaxation rate constants (R1, R2, R2*) were measured as a function of ferumoxytol concentration, and relaxivities (r1, r2, r2*) were calculated. A linear dependence of R1, R2, and R2* on ferumoxytol concentration was found in saline and plasma with lower R1 values at 3.0 T and similar R2 and R2* values at 1.5 T and 3.0 T (1.5 T: r1saline = 19.9 ± 2.3 smM; r1plasma = 19.0 ± 1.7 smM; r2saline = 60.8 ± 3.8 smM; r2plasma = 64.9 ± 1.8 smM; r2*saline = 60.4 ± 4.7 smM; r2*plasma = 64.4 ± 2.5 smM; 3.0 T: r1saline = 10.0 ± 0.3 smM; r1plasma = 9.5 ± 0.2 smM; r2saline = 62.3 ± 3.7 smM; r2plasma = 65.2 ± 1.8 smM; r2*saline = 57.0 ± 4.7 smM; r2*plasma = 55.7 ± 4.4 smM). The dependence of relaxation rates on concentration in blood was nonlinear. Formulas from second-order polynomial fittings of the relaxation rates were calculated to characterize the relationship between R1blood and R2 blood with ferumoxytol. Ferumoxytol demonstrates strong longitudinal and transverse relaxivities. Awareness of the nonlinear relaxation behavior of ferumoxytol in blood is important for ferumoxytol-enhanced magnetic resonance imaging applications and for protocol optimization.

  7. Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Roque, Andreia; Ramalho, Miguel; AlObaidy, Mamdoh; Heredia, Vasco; Burke, Lauren M.; De Campos, Rafael O.P.; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2014-10-15

    Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. To compare the image quality of three different post-contrast T1-weighted imaging techniques - standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE) - acquired in pediatric patients younger than 5 years of age. Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential. (orig.)

  8. Zero-point quantum fluctuations and dark energy

    International Nuclear Information System (INIS)

    Maggiore, Michele

    2011-01-01

    In the Hamiltonian formulation of general relativity, the energy associated to an asymptotically flat space-time with metric g μν is related to the Hamiltonian H GR by E=H GR [g μν ]-H GR [η μν ], where the subtraction of the flat-space contribution is necessary to get rid of an otherwise divergent boundary term. This classic result indicates that the energy associated to flat space does not gravitate. We apply the same principle to study the effect of the zero-point fluctuations of quantum fields in cosmology, proposing that their contribution to cosmic expansion is obtained computing the vacuum energy of quantum fields in a Friedmann-Robertson-Walker space-time with Hubble parameter H(t) and subtracting from it the flat-space contribution. Then the term proportional to Λ c 4 (where Λ c is the UV cutoff) cancels, and the remaining (bare) value of the vacuum energy density is proportional to Λ c 2 H 2 (t). After renormalization, this produces a renormalized vacuum energy density ∼M 2 H 2 (t), where M is the scale where quantum gravity sets is, so for M of the order of the Planck mass a vacuum energy density of the order of the critical density can be obtained without any fine-tuning. The counterterms can be chosen so that the renormalized energy density and pressure satisfy p=wρ, with w a parameter that can be fixed by comparison to the observed value, so, in particular, one can choose w=-1. An energy density evolving in time as H 2 (t) is however observationally excluded as an explanation for the dominant dark energy component that is responsible for the observed acceleration of the Universe. We rather propose that zero-point vacuum fluctuations provide a new subdominant ''dark'' contribution to the cosmic expansion that, for a UV scale M slightly smaller than the Planck mass, is consistent with existing limits and potentially detectable.

  9. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Fellner, Franz A. [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria) and Zentrales Radiologie Institut, Allgemeines Krankenhaus der Stadt Linz, Krankenhausstr. 9, 4020 Linz (Austria)]. E-mail: franz.fellner@akh.linz.at; Fellner, Claudia [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria); Aichner, Franz T. [Abteilung fuer Neurologie, Landes-Nervenklinik Wagner-Jauregg, Linz (Austria); Moelzer, Guenther [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria)

    2005-11-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 {mu}s, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis.

  10. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    International Nuclear Information System (INIS)

    Fellner, Franz A.; Fellner, Claudia; Aichner, Franz T.; Moelzer, Guenther

    2005-01-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 μs, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis

  11. The value of 3D T1-weighted gradient-echo MR imaging for evaluation of the appendix during pregnancy: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Kim, Seong Hyun; Choi, Dongil; Lee, Soon Jin; Rhim, Hyunchul; Park, Min Jung (Depts. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kshyun@skku.edu

    2011-10-15

    Background The use of oral contrast has been essential for the identification of a normal appendix on MR imaging during pregnancy. However, stool could be used as a positive oral contrast as it is characterized by a relatively high signal on T1-weighted imaging, and 3D T1-weighted gradient-echo (T1W-GRE) MR imaging has been used to evaluate 3 mm diameter intestines in fetuses. Purpose To evaluate the added value of 3D T1W-GRE MR imaging in combination with T2-weighted imaging (T2WI) compared to T2WI alone for evaluating the appendix during pregnancy. Material and Methods Eighteen consecutive pregnant patients who were clinically suspected of having acute appendicitis underwent appendix MR imaging which included T2WI with or without spectral presaturation attenuated inversion-recovery (SPAIR) fat suppression, and 3D T1W-GRE with SPAIR fat suppression. Two radiologists reviewed the two image sets (the T2WI set and the combined set of T2WI and 3D T1W-GRE images). Pathologic and clinical results served as the reference standard. The differences in the degree of visibility of the appendix and confidence scale for diagnosing acute appendicitis between two image sets were compared by using the paired Wilcoxon signed rank test. Results For both reviewers, the degree of visibility of the appendix using the combined T2WI and 3D T1W-GRE images was significantly higher than using T2WI alone (P < 0.01), and the confidence levels for acute appendicitis using combined T2WI and 3D T1W-GRE images were significantly different from those using T2WI alone (P < 0.01). In the 13 patients with a normal appendix, both reviewers showed improved confidence levels for appendicitis using combined T2WI and 3D T1W-GRE images than T2WI alone. Conclusion Adding 3D T1W-GRE images to T2WI is helpful for identification of the appendix, as compared to T2WI alone in pregnant women without ingestion of oral contrast material. This may improve diagnostic confidence for acute appendicitis in pregnant

  12. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  13. T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound

    International Nuclear Information System (INIS)

    Wintermark, Max; Sumer, Suna; Lau, Benison; Cupino, Alan; Tustison, Nicholas J; Demartini, Nicholas; Elias, William J; Kassell, Neal; Patrie, James T; Xin, Wenjun; Eames, Matt; Snell, John; Hananel, Arik; Aubry, Jean-Francois

    2014-01-01

    Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called ‘virtual CT’ to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland–Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (−0.22–0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the

  14. A modified generalized Chaplygin gas as the unified dark matter-dark energy revisited

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Xue-Mei, E-mail: xmd@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing (China)

    2011-12-15

    A modified generalized Chaplygin gas (MGCG) is considered as the unified dark matter-dark energy revisited. The character of MGCG is endued with the dual role, which behaves as matter at early times and as a quiescence dark energy at late times. The equation of state for MGCG is p = -{alpha}{rho}/(1 + {alpha}) - {upsilon}(z){rho}{sup -{alpha}/(1 + {alpha})}, where {upsilon}(z) = -[{rho}0{sub c}(1 + z){sup 3}] {sup (1+{alpha})} (1 - {Omega}{sub 0B}){sup {alpha} {l_brace}{alpha}{Omega}0{sub DM} + {Omega}{sub 0DE} [{omega}{sub DE} + {alpha}(1 +{omega}{sub DE})](1 + z){sup 3}{omega}DE(1+{alpha}){r_brace}}. Some cosmological quantities, such as the densities of different components of the universe {Omega}{sub i} (i, respectively, denotes baryons, dark matter, and dark energy) and the deceleration parameter q, are obtained. The present deceleration parameter q{sub 0}, the transition redshift z{sub T}, and the redshift z{sub eq}, which describes the epoch when the densities in dark matter and dark energy are equal, are also calculated. To distinguish MGCG from others, we then apply the Statefinder diagnostic. Later on, the parameters ({alpha} and {omega}{sub DE}) of MGCG are constrained by combination of the sound speed c{sup 2}{sub s} , the age of the universe t{sub 0}, the growth factor m, and the bias parameter b. It yields {alpha} = -3.07{sup +5.66} {sub -4.98} x 10{sup -2} and {omega}{sub DE} = -1.05 {sup +0.06} {sub -0.11}. Through the analysis of the growth of density perturbations for MGCG, it is found that the energy will transfer from dark matter to dark energy which reach equal at z{sub e}{approx} 0.48 and the density fluctuations start deviating from the linear behavior at z {approx} 0.25 caused by the dominance of dark energy. (author)

  15. Low dark current p-on-n technology for space applications

    Science.gov (United States)

    Péré-Laperne, N.; Baier, N.; Cervera, C.; Santailler, J. L.; Lobre, C.; Cassillo, C.; Berthoz, J.; Destefanis, V.; Sam Giao, D.; Lamoure, A.

    2017-08-01

    Space applications are requiring low dark current in the long wave infrared at low operating temperature for low flux observation. The applications envisioned with this type of specification are namely scientific and planetary missions. Within the framework of the joint laboratory between Sofradir and the CEA-LETI, a specific development of a TV format focal plane array with a cut-off wavelength of 12.5μm at 40K has been carried out. For this application, the p on n technology has been used. It is based on an In doped HgCdTe absorbing material grown by Liquid Phase Epitaxy (LPE) and an As implanted junction area. This architecture allows decreasing both dark current and series resistance compared to the legacy n on p technology based on Hg vacancies. In this paper, the technological improvements are briefly described. These technological tunings led to a 35% decrease of dark current in the diffusion regime. CEA-LETI and Sofradir demonstrated the ability to use the p on n technology with a long cutoff wavelength in the infrared range.

  16. A Prospective Evaluation of T2-Weighted First-Pass Perfusion MR Imaging In Diagnosing Breast Neoplasms

    Institute of Scientific and Technical Information of China (English)

    XiaoJuanUu; RenyouZhai; TaoJiang; LiWang

    2004-01-01

    OBJECTIVE To compare the results from breast cancer patients who undergo T2-weighted first-pass perfusion imaging after dynamic contrast-enhanced T1-weighted imaging during the same examination,and to evaluate if T2-weighted imaging can provide additional diagnostic information over that obtained with Tl-weiahted imaaina.METHODS Twenty-nine patients with breast lesions verified by pathology (benign 12, malignant 17) underwent MR imaging with dynamic contrast-enhanced Tl-weighted imaging of the entire breasts,immediately followed by 6-sections of T2-weighted first-pass perfusion imaging of the lesions. The diagnostic indices were acquired by individual 3D Tl-weighted enhancement rate criterion and the T2 signalintensity loss rate criterion. The sensitivity and specificity were calculated and the 2 methods were compared.RESULTS With the dynamic contrast-enhanced T1-weighted imaging there was a significant differences breast lesions (t=2.563, P=0.016)overlap between the signal intensitybetween the benign and malignant However we found a considerable increase in the carcinomas and thatin the benign lesions, for a sensitivity of 94% and a specificity of 25%.With T2-weighted first-pass perfusion imaging, there was a very significant difference between the benign and malignant breast lesions(t=4.777,P<0.001), and the overlap between the signal intensity decrease in the carcinomas and that of the benign lesions on the T2-weighted images was less pronounced than the overlap in the T1-weighted images, for a sensitivity of 88% and a specificity of 75%.CONCLUSION T2-weighted first-pass perfusion imaging may help differentiate between benign and malignant breast lesions with a higher level of specificity. The combination of T1-weighted and T2-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

  17. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Ronot, Maxime; Vilgrain, Valerie; Beers, Bernard E. van [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique- Hopitaux de Paris, Laboratory of Physiological and Molecular Imaging of the Abdomen (IPMA) and Department of Radiology, Clichy Cedex (France); Maggiori, Leon; Panis, Yves [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Colorectal Surgery, Clichy (France); Paradis, Valerie [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Pathology, Clichy (France)

    2013-08-15

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm{sup 2}) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P {<=} 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. (orig.)

  18. Transverse water relaxation in whole blood and erythrocytes at 3T, 7T, 9.4T, 11.7T and 16.4T; determination of intracellular hemoglobin and extracellular albumin relaxivities.

    Science.gov (United States)

    Grgac, Ksenija; Li, Wenbo; Huang, Alan; Qin, Qin; van Zijl, Peter C M

    2017-05-01

    Blood is a physiological substance with multiple water compartments, which contain water-binding proteins such as hemoglobin in erythrocytes and albumin in plasma. Knowing the water transverse (R 2 ) relaxation rates from these different blood compartments is a prerequisite for quantifying the blood oxygenation level-dependent (BOLD) effect. Here, we report the Carr-Purcell-Meiboom-Gill (CPMG) based transverse (R 2CPMG ) relaxation rates of water in bovine blood samples circulated in a perfusion system at physiological temperature in order to mimic blood perfusion in humans. R 2CPMG values of blood plasma, lysed packed erythrocytes, lysed plasma/erythrocyte mixtures, and whole blood at 3 T, 7 T, 9.4 T, 11.7 T and 16.4 T were measured as a function of hematocrit or hemoglobin concentration, oxygenation, and CPMG inter-echo spacing (τ cp ). R 2CPMG in lysed cells showed a small τ cp dependence, attributed to the water exchange rate between free and hemoglobin-bound water to be much faster than τ cp . This was contrary to the tangential dependence in whole blood, where a much slower exchange between cells and blood plasma applies. Whole blood data were fitted as a function of τ cp using a general tangential correlation time model applicable for exchange as well as diffusion contributions to R 2CPMG , and the intercept R 20blood at infinitely short τ cp was determined. The R 20blood values at different hematocrit and the R 2CPMG values of lysed erythrocyte/plasma mixtures at different hemoglobin concentration were used to determine the relaxivity of hemoglobin inside the erythrocyte (r 2Hb ) and albumin (r 2Alb ) in plasma. The r 2Hb values obtained from lysed erythrocytes and whole blood were comparable at full oxygenation. However, while r 2Hb determined from lysed cells showed a linear dependence on oxygenation, this dependence became quadratic in whole blood. This possibly suggests an additional relaxation effect inside intact cells, perhaps due to hemoglobin

  19. Beyond birth-weight: early growth and adolescent blood pressure in a Peruvian population

    Directory of Open Access Journals (Sweden)

    Robie Sterling

    2014-06-01

    Full Text Available Background. Longitudinal investigations into the origins of adult essential hypertension have found elevated blood pressure in children to accurately track into adulthood, however the direct causes of essential hypertension in adolescence and adulthood remains unclear.Methods. We revisited 152 Peruvian adolescents from a birth cohort tracked from 0 to 30 months of age, and evaluated growth via monthly anthropometric measurements between 1995 and 1998, and obtained anthropometric and blood pressure measurements 11–14 years later. We used multivariable regression models to study the effects of infantile and childhood growth trends on blood pressure and central obesity in early adolescence.Results. In regression models adjusted for interim changes in weight and height, each 0.1 SD increase in weight for length from 0 to 5 months of age, and 1 SD increase from 6 to 30 months of age, was associated with decreased adolescent systolic blood pressure by 1.3 mm Hg (95% CI −2.4 to −0.1 and 2.5 mm Hg (95% CI −4.9 to 0.0, and decreased waist circumference by 0.6 (95% CI −1.1 to 0.0 and 1.2 cm (95% CI −2.3 to −0.1, respectively. Growth in infancy and early childhood was not significantly associated with adolescent waist-to-hip ratio.Conclusions. Rapid compensatory growth in early life has been posited to increase the risk of long-term cardiovascular morbidities such that nutritional interventions may do more harm than good. However, we found increased weight growth during infancy and early childhood to be associated with decreased systolic blood pressure and central adiposity in adolescence.

  20. Indirect detection constraints on s- and t-channel simplified models of dark matter

    Science.gov (United States)

    Carpenter, Linda M.; Colburn, Russell; Goodman, Jessica; Linden, Tim

    2016-09-01

    Recent Fermi-LAT observations of dwarf spheroidal galaxies in the Milky Way have placed strong limits on the gamma-ray flux from dark matter annihilation. In order to produce the strongest limit on the dark matter annihilation cross section, the observations of each dwarf galaxy have typically been "stacked" in a joint-likelihood analysis, utilizing optical observations to constrain the dark matter density profile in each dwarf. These limits have typically been computed only for singular annihilation final states, such as b b ¯ or τ+τ- . In this paper, we generalize this approach by producing an independent joint-likelihood analysis to set constraints on models where the dark matter particle annihilates to multiple final-state fermions. We interpret these results in the context of the most popular simplified models, including those with s- and t-channel dark matter annihilation through scalar and vector mediators. We present our results as constraints on the minimum dark matter mass and the mediator sector parameters. Additionally, we compare our simplified model results to those of effective field theory contact interactions in the high-mass limit.

  1. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, 466-8550, Nagoya (Japan); Aoki, Ikuo [Medical System Company, Toshiba Corporation, Tokyo (Japan)

    2003-12-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 ) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in

  2. Molecular Weight Dependent Glucose Lowering Effect of Low Molecular Weight Chitosan Oligosaccharide (GO2KA1 on Postprandial Blood Glucose Level in SD Rats Model

    Directory of Open Access Journals (Sweden)

    Emmanouil Apostolidis

    2013-07-01

    Full Text Available This research investigated the effect of enzymatically digested low molecular weight (MW chitosan oligosaccharide on type 2 diabetes prevention. Three different chitosan oligosaccharide samples with varying MW were evaluated in vitro for inhibition of rat small intestinal α-glucosidase and porcine pancreatic α-amylase (GO2KA1; 10,000 Da. The in vitro results showed that all tested samples had similar rat α-glucosidase inhibitory and porcine α-amylase inhibitory activity. Based on these observations, we decided to further investigate the effect of all three samples at a dose of 0.1 g/kg, on reducing postprandial blood glucose levels in Sprague-Dawley (SD rat model after sucrose loading test. In the animal trial, all tested samples had postprandial blood glucose reduction effect, when compared to control, however GO2KA1 supplementation had the strongest effect. The glucose peak (Cmax for GO2KA1 and control was 152 mg/dL and 193 mg/dL, respectively. The area under the blood glucose-time curve (AUC for GO2KA1 and control was 262 h mg/dL and 305 h mg/dL, respectively. Furthermore, the time of peak plasma concentration of blood glucose (Tmax for GO2KA1 was significantly delayed (0.9 h compared to control (0.5 h. These results suggest that GO2KA1 could have a beneficial effect for blood glucose management relevant to diabetes prevention in normal and pre-diabetic individuals. The suggested mechanism of action is via inhibition of the carbohydrate hydrolysis enzyme α-glucosidase and since GO2KA1 (MW < 1000 Da had higher in vivo effect, we hypothesize that it is more readily absorbed and might exert further biological effect once it is absorbed in the blood stream, relevant to blood glucose management.

  3. Weighted Differentiation Composition Operator from Logarithmic Bloch Spaces to Zygmund-Type Spaces

    Directory of Open Access Journals (Sweden)

    Huiying Qu

    2014-01-01

    Full Text Available Let H( denote the space of all holomorphic functions on the unit disk of ℂ, u∈H( and let  n be a positive integer, φ a holomorphic self-map of , and μ a weight. In this paper, we investigate the boundedness and compactness of a weighted differentiation composition operator φ,unf(z=u(zf(n(φ(z,f∈H(, from the logarithmic Bloch spaces to the Zygmund-type spaces.

  4. Status and prospects of light bino-higgsino dark matter in natural SUSY

    Energy Technology Data Exchange (ETDEWEB)

    Abdughani, Murat; Yang, Jin Min [Chinese Academy of Sciences, CAS Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Beijing (China); University of Chinese Academy of Sciences, School of Physical Sciences, Beingjing (China); Wu, Lei [Nanjing Normal University, Department of Physics and Institude of Theoretical Physics, Nanjing, Jiangsu (China)

    2018-01-15

    Given the recent progress in dark matter direction detection experiments, we examine a light bino-higgsino dark matter (DM) scenario (M{sub 1} < 100 GeV and μ < 300 GeV) in natural supersymmetry with the electroweak fine tuning measure Δ{sub EW} < 30. By imposing various constraints, we note that: (i) For sign(μ/M{sub 1}) = +1, the parameter space allowed by the DM relic density and collider bounds can almost be excluded by the very recent spin-independent (SI) scattering cross-section limits from the XENON1T (2017) experiment. (ii) For sign(μ/M{sub 1}) = -1, the SI limits can be evaded due to the cancelation effects in the hχ{sup 0}{sub 1}χ{sup 0}{sub 1} coupling, while rather stringent constraints come from the PandaX-II (2016) spin-dependent (SD) scattering cross-section limits, which can exclude the higgsino mass vertical stroke μ vertical stroke and the LSP mass m{sub χ{sup 0}{sub 1}} up to about 230 and 37 GeV, respectively. Furthermore, the surviving parameter space will be fully covered by the projected XENON1T experiment or the future trilepton searches at the HL-LHC. (orig.)

  5. Magnetization transfer imaging identifies basal ganglia abnormalities in adult ADHD that are invisible to conventional T1 weighted voxel-based morphometry

    Directory of Open Access Journals (Sweden)

    Arjun Sethi

    2017-01-01

    Full Text Available In childhood, Attention Deficit Hyperactivity Disorder (ADHD is reliably associated with reduced volume of the striatum. In contrast, striatal abnormalities are infrequently detected in voxel-based morphometry (VBM neuroimaging studies of adults with ADHD. This discrepancy has been suggested to reflect normalisation of striatal morphology with age and prolonged treatment of symptoms. If so, this would indicate that while striatal abnormalities are linked to symptom expression in childhood, they cannot explain the persistence of these symptoms in adulthood. However, this may not be case. Instead, we hypothesized that the lack of evidence for striatal abnormalities in adult ADHD may reflect poor sensitivity of typical (T1-weighted neuroimaging to detect subcortical differences. To address this, we acquired both magnetisation transfer (MT saturation maps optimised for subcortical contrast, and conventional T1-weighted images in 30 adults with ADHD and 30 age, IQ, gender and handedness-matched controls. Using VBM of both datasets, we demonstrate volumetric reductions within the left ventral striatum on MT that are not observed on identically pre-processed T1-weighted images from the same participants. Nevertheless, both techniques reported similar sensitivity to cortical abnormalities in the right inferior parietal lobe. Additionally, we show that differences in striatal iron may potentially explain this reduced sensitivity of T1-weighted images in adults. Together, these findings indicate that prior VBM studies reporting no abnormalities in striatal volume in adult ADHD might have been compromised by the methodological insensitivity of T1-weighted VBM to subcortical differences, and that structural abnormalities of the striatum in ADHD do indeed persist into adulthood.

  6. Assessment of T2-Weighted Coronal Magnetic Resonance Images in the Investigation of Pituitary Lesions

    International Nuclear Information System (INIS)

    Yuksekkaya, Ruken; Aggunlu, Levent; Oner, Yusuf; Celik, Halil; Akpek, Sergin; Celikyay, Fatih

    2014-01-01

    Magnetic resonance imaging is the most important diagnostic method in the investigation of the pituitary lesions. Our aim is to determine whether T2-weighted coronal images may be helpful in the evaluation of the pituitary gland with suspected pituitary adenomas. One hundred and sixty-seven patients were examined prospectively with T2-weighted coronal and T1-weighted coronal images enhanced with intravenous contrast material. The images were evaluated for the presence, the size, the location, and the ancillary signs including sellar floor erosion or ballooning, infindibulary deviation, convexity of the superior border of the gland, diffuse enlargement of the gland, and the invasion of the cavenous sinuses on both images. In forty-six (28%) patients lesions were revealed on both sequences. In twenty-one (12%) patients the lesions that were revealed on the T1-weighted images were not detected on the T2-weighted images. Positive predictive value, negative predictive value, sensitivity, specificity, and diagnostic accuracy rates of T2-weighted coronal images on the detection of the presence of lesions were 100%, 17.4%, 68.7%, 100%, and 87.4%, respectively. Both T2-weighted coronal and T1-weighted coronal images enhanced with intravenous gadolinium-based contrast material are important in the diagnosis of pituitary adenomas. T2-weighted coronal images could be used as a screening tool for the primary evaluation of the pituitary gland

  7. Impairment of T-regulatory cells in cord blood of atopic mothers.

    Science.gov (United States)

    Schaub, Bianca; Liu, Jing; Höppler, Sabine; Haug, Severine; Sattler, Christine; Lluis, Anna; Illi, Sabina; von Mutius, Erika

    2008-06-01

    Maternal atopy is a strong predictor for the development of childhood allergic diseases. The underlying mechanisms are ill defined, yet regulatory T (Treg) and T(H)17 cells may play a key role potentially shaping the early immune system toward a proallergic or antiallergic immune regulation. We examined T(H)1/T(H)2, Treg, and T(H)17 cell responses to innate (lipid A/peptidoglycan) and mitogen/adaptive (phytohemagglutinin/Dermatophagoides pteronyssinus 1) immune stimulation in cord blood from offspring of atopic/nonatopic mothers. Cord blood mononuclear cells from 161 healthy neonates (59% nonatopic, 41% atopic mothers) were investigated regarding Treg and T(H)17 cells (mRNA/surface markers), suppressive function, and proliferation/cytokine secretion. Cord blood from offspring of atopic mothers showed fewer innate-induced Treg cells (CD4(+)CD25(+)high), lower mRNA expression of associated markers (glucocorticoid-induced tumor necrosis factor receptor-related protein/lymphocyte activation gene 3; P cell function was impaired in mitogen-induced suppression of T effector cells in cord blood of offspring from atopic mothers (P = .03). Furthermore, IL-10 and IFN-gamma secretion were decreased in innate-stimulated cord blood of offspring from atopic mothers (P = .04/.05). Innate-induced IL-17 was independent of maternal atopy and highly correlated with IL-13 secretion. In offspring of atopic mothers, Treg cell numbers, expression, and function were impaired at birth. T(H)17 cells were correlated with T(H)2 cells, independently of maternal atopy.

  8. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    Science.gov (United States)

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Quantitative T1 and T2* carotid atherosclerotic plaque imaging using a three-dimensional multi-echo phase-sensitive inversion recovery sequence: a feasibility study.

    Science.gov (United States)

    Fujiwara, Yasuhiro; Maruyama, Hirotoshi; Toyomaru, Kanako; Nishizaka, Yuri; Fukamatsu, Masahiro

    2018-06-01

    Magnetic resonance imaging (MRI) is widely used to detect carotid atherosclerotic plaques. Although it is important to evaluate vulnerable carotid plaques containing lipids and intra-plaque hemorrhages (IPHs) using T 1 -weighted images, the image contrast changes depending on the imaging settings. Moreover, to distinguish between a thrombus and a hemorrhage, it is useful to evaluate the iron content of the plaque using both T 1 -weighted and T 2 *-weighted images. Therefore, a quantitative evaluation of carotid atherosclerotic plaques using T 1 and T 2 * values may be necessary for the accurate evaluation of plaque components. The purpose of this study was to determine whether the multi-echo phase-sensitive inversion recovery (mPSIR) sequence can improve T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of an IPH. T 1 and T 2 * values measured using mPSIR were compared to values from conventional methods in phantom and in vivo studies. In the phantom study, the T 1 and T 2 * values estimated using mPSIR were linearly correlated with those of conventional methods. In the in vivo study, mPSIR demonstrated higher T 1 contrast between the IPH phantom and sternocleidomastoid muscle than the conventional method. Moreover, the T 1 and T 2 * values of the blood vessel wall and sternocleidomastoid muscle estimated using mPSIR were correlated with values measured by conventional methods and with values reported previously. The mPSIR sequence improved T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of the neck region. Although further study is required to evaluate the clinical utility, mPSIR may improve carotid atherosclerotic plaque detection and provide detailed information about plaque components.

  10. MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR

    International Nuclear Information System (INIS)

    Roy, C.; Ohana, M.; Host, Ph.; Alemann, G.; Labani, A.; Wattiez, A.; Lang, H.

    2014-01-01

    T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter.•T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis).•T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium.•CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction.•CE-MRU is less convenient for patients. T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter. T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis). T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium. CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction. CE-MRU is less convenient for patients. The goal of this prospective study was to compare the efficiency of two types of MRU after diuretic administration to identify the non-dilated ureter. MR pelvic examinations were performed in 126 patients after receiving furosemide. Each patient underwent in addition to their protocol for context, two types of MRU: 2D T2-weighted FSE (T2w-MRU) and 3D Gd T1-weighted GE (CE-MRU). Four segments were checked for each ureter. For the first part of the analysis, readers evaluated the whole image quality using a four points subjective scale and for the second part, they were asked to score separately each ureteral segment as present or absent. 1008 ureteral segments were checked. For the image quality, readers did not find any significant difference (3.8 ± 0.5 vs 3.6 ± 0.7, p value: 0.13) between MRU methods. The interobserver agreement was excellent with a κ correlation coefficient as high as 0.89 for T2w-MRU and 0.92 for CE

  11. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai

    1995-01-01

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 ± 1.8mm) than that of control group (2-9mm, mean: 6.2 ± 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality

  12. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1995-01-15

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 {+-} 1.8mm) than that of control group (2-9mm, mean: 6.2 {+-} 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality.

  13. Repair of damage induced by ultraviolet radiation in mutator T-1 Escherichia coli transductants

    International Nuclear Information System (INIS)

    Sideropoulos, A.S.; Greenberg, J.; Warren, G.

    1975-01-01

    To ascertain whether a relationship commonly exists between azide resistance, ultraviolet (uv) resistance, and the mutator property (mut T-1), we performed uv survival and mutation frequency determinations with and without caffeine (2.571 mM) in nonmutator azide resistant (azi/sup r/) and phage mediated mut T-1 transductants of Escherichia coli K-12, B/r, B/r T-, Bs-1, and Bs-8. The strains constructed were assumed to be ''co-isogenic'' except for the mutator factor. The frequency of mutation to streptomycin resistance (str/sup r/) was relatively constant and approximated 2 x 10- 7 . Transductants carrying the azide marker with or without the mut T-1 gene had the same level of uv survival as the parent with the same mutator phenotype. Dark repair of the prelethal uv lesion is equally caffeine sensitive in the nonmutator and mutator HCR+ strains. Our results indicated that the mut T-1 strains possess an efficient dark repair system for uv damage and that the mechanism of mut T-1 action is independent of uv dark repair processes. (auth)

  14. Specific immunotherapy effect on peripheral blood T1/T2 lymphocytes in atopic patients

    Directory of Open Access Journals (Sweden)

    Manuela Rebordão

    2006-03-01

    Full Text Available Allergen-specific immunotherapy has been used for successful treatment of atopic diseases. They may act by modifying the patterns of cytokines produced by T cells. However, the precise mechanism by which it accomplishes these effects is still incompletely understood. Objective: To evaluate the effect of one year immunotherapy on cytokines profiles T1 and T2 of peripheral blood lymphocytes in atopic patients. Methods: We studied 10 atopic patients sensitised to common environmental allergens receiving immunotherapy over one year mean period. Six of these patients were studied before and after immunotherapy. Fourteen atopic patients untreated and 7 non-atopic subjects were used as control groups. Intracellular cytokine production (IFN-γ; IL-4; IL- 5; IL-10 was determined by flow cytometry following stimulation with phorbol myristate acetate (PMA, ionomycin and brefeldin. Mann-Whitney U and Wilcoxon non-parametric tests were utilized for the statistical analysis. Results: The expression of IL-4 and IL-5 in T cells, characteristically increased in atopic patients, respectively 13.8 (3.1 – 31.8 and 6.7% (1.0 -20.4, was significantly lower in the immunotherapy group 5.4 (2.9 -15.6 p=0.007 and 2.1% (0,6 – 4.8 p=0.035 and similar in the non-atopic control group. The levels of IFN-γ did not differ between the studied groups but the ratio IFN-γ / IL-4 produced by CD4+ T lymphocytes increased significantly in the patients receiving immunotherapy. In addition, there was an increase in the expression of IL-10 by T cells of the immunotherapy group compared to the non-atopic controls 1.9 (1.0 – 4.9 versus 1.4% (0.9 – 1.4 p=0.02, being more evident in CD8+ T lymphocytes. IL-10 correlated significantly with all the profile T2 cytokines (IL-4 and IL-5 and with the phenotype Tc2. Conclusion: After one year of immunotherapy the peripheral T cells response to a polyclonal stimulation revealed a reduction in IL-4 and IL-5 production

  15. 31P-MR spectroscopy of all regions of the human heart at 1.5 T with acquisition-weighted chemical shift imaging

    International Nuclear Information System (INIS)

    Koestler, H.; Beer, M.; Buchner, S.; Sandstede, J.; Pabst, T.; Kenn, W.; Hahn, D.

    2001-01-01

    Aim: Aim of this study was to show whether or not acquisition-weighted chemical shift imaging (AW-CSI) allows the determination of PCr and ATP in the lateral and posterior wall of the human heart at 1.5 T. Methods: 12 healthy volunteers were examined using a conventional chemical shift imaging (CSI) and an AW-CSI. The sequences differed only in the number of repetitions for each point in k space. A hanning function was used as filter function leading to 7 repetitions in the center of the k space and 0 in the corners. Thus, AW-CSI had the same resolution as the CSI sequence. The results for both sequences were analyzed using identically positioned voxels in the septal, anterior, lateral and posterior wall. Results: The determined averaged AW-CSI signal to noise ratios were higher for PCr by a factor of 1.3 and for ATP by 1.4 than those of CSI. The PCr/ATP ratios were higher by a factor of 1.2 - 1.3 and showed a smaller standard deviation in all locations for AW-CSI. The mean PCr/ATP ratios determined by AW-CSI of septal, lateral and posterior wall were almost identical (1.72 - 1.76), while it was higher in the anterior wall (1.9). Conclusions: The reduced contamination in AW-CSI improves the signal to noise ratio and the determination of the PCr/ATP ratio in cardiac 31 P spectroscopy compared to CSI with the same resolution. The results in volunteers indicate that AW-CSI renders 31 P spectroscopy of the lateral and posterior wall of the human heart feasible for patient studies at 1.5 T. (orig.) [de

  16. Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    Science.gov (United States)

    Clavijo Jordan, M Veronica; Beeman, Scott C; Baldelomar, Edwin J; Bennett, Kevin M

    2014-01-01

    Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have limited in vivo detection due to a number of constraints with T2 or T2*-weighted imaging. T1-weighted imaging is often preferred for molecular MRI, but most T1-shortening agents are small chelates with low metal payload or are nanoparticles that also shorten T2 and limit the range of concentrations detectable with T1-weighting. Here we used tungsten and iron deposition to form doped iron oxide crystals inside the apoferritin cavity to form a WFe nanoparticle with a disordered crystal and un-coupled atomic magnetic moments. The atomic magnetic moments were thus localized, resulting in a principally paramagnetic nanoparticle. The WFe nanoparticles had no coercivity or saturation magnetization at 5 K and sweeping up to ± 20,000 Oe, while native ferritin had a coercivity of 3000 Oe and saturation at ± 20,000 Oe. This tungsten-iron crystal paramagnetism resulted in an increased WFe particle longitudinal relaxivity (r1) of 4870 mm(-1) s(-1) and a reduced transverse relaxivity (r2) of 9076 mm(-1) s(-1) compared with native ferritin. The accumulation of the particles was detected with T1-weighted MRI in concentrations from 20 to 400 nm in vivo, both injected in the rat brain and targeted to the rat kidney glomerulus. The WFe apoferritin nanoparticles were not cytotoxic up to 700 nm particle concentrations, making them potentially important for targeted molecular MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Charming dark matter

    Science.gov (United States)

    Jubb, Thomas; Kirk, Matthew; Lenz, Alexander

    2017-12-01

    We have considered a model of Dark Minimal Flavour Violation (DMFV), in which a triplet of dark matter particles couple to right-handed up-type quarks via a heavy colour-charged scalar mediator. By studying a large spectrum of possible constraints, and assessing the entire parameter space using a Markov Chain Monte Carlo (MCMC), we can place strong restrictions on the allowed parameter space for dark matter models of this type.

  18. Comparison of detection pattern of HCC by ferumoxide-enhanced MRI and intratumoral blood flow pattern

    International Nuclear Information System (INIS)

    Itou, Naoki; Kotake, Fumio; Saitou, Kazuhiro; Abe, Kimihiko

    2000-01-01

    We compared the detection rate and pattern of ferumoxide-enhanced magnetic resonance imaging (Fe-MRI) with the intratumoral blood flow pattern determined by CT angiography (CTA) and CT portography (CTAP) in 124 nodes (34 cases) diagnosed as hepatocellular carcinoma (HCC) or borderline HCC, based on the clinical course. Sequences to obtain a T1-weighted images (T1W), proton density-weighted images (PDW), T2-weighted images (T2W), T2*-weighted images (T2*W) were used in Fe-MRI. In nodes shown to be hypervascular on CTA, the detection rate by Fe-MRI was 69.7%. In nodes shown to be avascular by CTAP, the detection rate by Fe-MRI was 67.3%. These rates were higher than with other flow patterns. In nodes showing high signal intensity (HSI) on any sequences, arterial blood flow was increased and portal blood flow decreased in comparison with nodes without high signal intensity. All nodes showing HSI, both on Fe-MRI T2W and T2*W, were hypervascular on CTA, and portal blood flow was absent on CTAP. Nodes showing HSI on both T2*W and T2W were considered to have greater arterial blood flow and decreased portal blood flow compared with nodes appearing as HSI on T2*W, but only as iso- or low signal intensity on T2W (Mann-Whitney U-test; p<0.05). (author)

  19. New limits on coupled dark energy model after Planck 2015

    Science.gov (United States)

    Li, Hang; Yang, Weiqiang; Wu, Yabo; Jiang, Ying

    2018-06-01

    We used the Planck 2015 cosmic microwave background anisotropy, baryon acoustic oscillation, type-Ia supernovae, redshift-space distortions, and weak gravitational lensing to test the model parameter space of coupled dark energy. We assumed the constant and time-varying equation of state parameter for dark energy, and treated dark matter and dark energy as the fluids whose energy transfer was proportional to the combined term of the energy densities and equation of state, such as Q = 3 Hξ(1 +wx) ρx and Q = 3 Hξ [ 1 +w0 +w1(1 - a) ] ρx, the full space of equation of state could be measured when we considered the term (1 +wx) in the energy exchange. According to the joint observational constraint, the results showed that wx = - 1.006-0.027+0.047 and ξ = 0.098-0.098>+0.026 for coupled dark energy with a constant equation of state, w0 = -1.076-0.076+0.085, w1 = - 0.069-0.319+0.361, and ξ = 0.210-0.210+0.048 for a variable equation of state. We did not get any clear evidence for the coupling in the dark fluids at 1 σ region.

  20. Direct reconstruction of dark energy.

    Science.gov (United States)

    Clarkson, Chris; Zunckel, Caroline

    2010-05-28

    An important issue in cosmology is reconstructing the effective dark energy equation of state directly from observations. With so few physically motivated models, future dark energy studies cannot only be based on constraining a dark energy parameter space. We present a new nonparametric method which can accurately reconstruct a wide variety of dark energy behavior with no prior assumptions about it. It is simple, quick and relatively accurate, and involves no expensive explorations of parameter space. The technique uses principal component analysis and a combination of information criteria to identify real features in the data, and tailors the fitting functions to pick up trends and smooth over noise. We find that we can constrain a large variety of w(z) models to within 10%-20% at redshifts z≲1 using just SNAP-quality data.

  1. Evolution of the phase-space density and the Jeans scale for dark matter derived from the Vlasov-Einstein equation

    International Nuclear Information System (INIS)

    Piattella, O.F.; Rodrigues, D.C.; Fabris, J.C.; Pacheco, J.A. de Freitas

    2013-01-01

    We discuss solutions of Vlasov-Einstein equation for collisionless dark matter particles in the context of a flat Friedmann universe. We show that, after decoupling from the primordial plasma, the dark matter phase-space density indicator Q = ρ/(σ 1D 2 ) 3/2 remains constant during the expansion of the universe, prior to structure formation. This well known result is valid for non-relativistic particles and is not ''observer dependent'' as in solutions derived from the Vlasov-Poisson system. In the linear regime, the inclusion of velocity dispersion effects permits to define a physical Jeans length for collisionless matter as function of the primordial phase-space density indicator: λ J = (5π/G) 1/2 Q −1/3 ρ dm −1/6 . The comoving Jeans wavenumber at matter-radiation equality is smaller by a factor of 2-3 than the comoving wavenumber due to free-streaming, contributing to the cut-off of the density fluctuation power spectrum at the lowest scales. We discuss the physical differences between these two scales. For dark matter particles of mass equal to 200 GeV, the derived Jeans mass is 4.3 × 10 −6 M ⊙

  2. Twin Higgs Asymmetric Dark Matter.

    Science.gov (United States)

    García García, Isabel; Lasenby, Robert; March-Russell, John

    2015-09-18

    We study asymmetric dark matter (ADM) in the context of the minimal (fraternal) twin Higgs solution to the little hierarchy problem, with a twin sector with gauged SU(3)^{'}×SU(2)^{'}, a twin Higgs doublet, and only third-generation twin fermions. Naturalness requires the QCD^{'} scale Λ_{QCD}^{'}≃0.5-20  GeV, and that t^{'} is heavy. We focus on the light b^{'} quark regime, m_{b^{'}}≲Λ_{QCD}^{'}, where QCD^{'} is characterized by a single scale Λ_{QCD}^{'} with no light pions. A twin baryon number asymmetry leads to a successful dark matter (DM) candidate: the spin-3/2 twin baryon, Δ^{'}∼b^{'}b^{'}b^{'}, with a dynamically determined mass (∼5Λ_{QCD}^{'}) in the preferred range for the DM-to-baryon ratio Ω_{DM}/Ω_{baryon}≃5. Gauging the U(1)^{'} group leads to twin atoms (Δ^{'}-τ^{'}[over ¯] bound states) that are successful ADM candidates in significant regions of parameter space, sometimes with observable changes to DM halo properties. Direct detection signatures satisfy current bounds, at times modified by dark form factors.

  3. Distribution function approach to redshift space distortions. Part V: perturbation theory applied to dark matter halos

    Energy Technology Data Exchange (ETDEWEB)

    Vlah, Zvonimir; Seljak, Uroš [Institute for Theoretical Physics, University of Zürich, Zürich (Switzerland); Okumura, Teppei [Institute for the Early Universe, Ewha Womans University, Seoul, S. Korea (Korea, Republic of); Desjacques, Vincent, E-mail: zvlah@physik.uzh.ch, E-mail: seljak@physik.uzh.ch, E-mail: teppei@ewha.ac.kr, E-mail: Vincent.Desjacques@unige.ch [Département de Physique Théorique and Center for Astroparticle Physics (CAP) Université de Genéve, Genéve (Switzerland)

    2013-10-01

    Numerical simulations show that redshift space distortions (RSD) introduce strong scale dependence in the power spectra of halos, with ten percent deviations relative to linear theory predictions even on relatively large scales (k < 0.1h/Mpc) and even in the absence of satellites (which induce Fingers-of-God, FoG, effects). If unmodeled these effects prevent one from extracting cosmological information from RSD surveys. In this paper we use Eulerian perturbation theory (PT) and Eulerian halo biasing model and apply it to the distribution function approach to RSD, in which RSD is decomposed into several correlators of density weighted velocity moments. We model each of these correlators using PT and compare the results to simulations over a wide range of halo masses and redshifts. We find that with an introduction of a physically motivated halo biasing, and using dark matter power spectra from simulations, we can reproduce the simulation results at a percent level on scales up to k ∼ 0.15h/Mpc at z = 0, without the need to have free FoG parameters in the model.

  4. IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T

    Science.gov (United States)

    Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir

    2015-01-01

    Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236

  5. ChLae1 and ChVel1 regulate T-toxin production, virulence, oxidative stress response, and development of the maize pathogen Cochliobolus heterostrophus.

    Directory of Open Access Journals (Sweden)

    Dongliang Wu

    2012-02-01

    Full Text Available LaeA and VeA coordinate secondary metabolism and differentiation in response to light signals in Aspergillus spp. Their orthologs, ChLae1 and ChVel1, were identified in the maize pathogen Cochliobolus heterostrophus, known to produce a wealth of secondary metabolites, including the host selective toxin, T-toxin. Produced by race T, T-toxin promotes high virulence to maize carrying Texas male sterile cytoplasm (T-cms. T-toxin production is significantly increased in the dark in wild type (WT, whereas Chvel1 and Chlae1 mutant toxin levels are much reduced in the dark compared to WT. Correspondingly, expression of T-toxin biosynthetic genes (Tox1 is up-regulated in the dark in WT, while dark-induced expression is much reduced/minimal in Chvel1 and Chlae1 mutants. Toxin production and Tox1 gene expression are increased in ChVEL1 overexpression (OE strains grown in the dark and in ChLAE1 strains grown in either light or dark, compared to WT. These observations establish ChLae1 and ChVel1 as the first factors known to regulate host selective toxin production. Virulence of Chlae1 and Chvel1 mutants and OE strains is altered on both T-cms and normal cytoplasm maize, indicating that both T-toxin mediated super virulence and basic pathogenic ability are affected. Deletion of ChLAE1 or ChVEL1 reduces tolerance to H(2O(2. Expression of CAT3, one of the three catalase genes, is reduced in the Chvel1 mutant. Chlae1 and Chvel1 mutants also show decreased aerial hyphal growth, increased asexual sporulation and female sterility. ChLAE1 OE strains are female sterile, while ChVEL1 OE strains are more fertile than WT. ChLae1 and ChVel1 repress expression of 1,8-dihydroxynaphthalene (DHN melanin biosynthesis genes, and, accordingly, melanization is enhanced in Chlae1 and Chvel1 mutants, and reduced in OE strains. Thus, ChLae1 and ChVel1 positively regulate T-toxin biosynthesis, pathogenicity and super virulence, oxidative stress responses, sexual development, and

  6. High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yokoyama, Shunichi; Uomizu, Kenji; Kajiya, Yoriko; Tajitsu, Kenichiro; Kusumoto, Kazuhiro; Hirano, Hirofumi

    2005-01-01

    The incidence and characteristics of microbleeds in hemodialysis (HD) patients were investigated to elucidate the clinical significance with T 2 * -weighted gradient-echo magnetic resonance (MR) imaging. The 57 patients with chronic renal failure maintained by HD had no previous history of stroke. The control group consisted of 53 patients without previous history of stroke or chronic renal failure. The incidence and the number of microbleeds were assessed in the HD and control groups. The findings of microbleeds with T 2 * -weighted gradient-echo MR imaging were compared with those of T 1 - and T 2 -weighted MR imaging in HD patients. The incidence of microbleeds was significantly greater in the HD patients compared with the control patients. T 2 * -weighted gradient-echo imaging revealed a total of 44 microbleeds in 11 HD patients. T 2 -weighted imaging demonstrated 13 of 44 microbleeds as hyperintensity, whereas T 1 -weighted imaging demonstrated 12 lesions as hypointensity. T 2 - and T 1 -weighted imagings did not demonstrate any findings in 31 and 32 lesions, respectively. T 2 * -weighted gradient-echo MR imaging is effective to detect microbleeds which may be a predictor of intracerebral hemorrhage in HD patients and should be included in the protocol for the study of cerebrovascular disease, because T 2 - and T 1 -weighted MR imaging recognizes microbleeds as lacunar infarction. (author)

  7. Direct visualization of antigen-specific T cells: HTLV-1 Tax11-19- specific CD8(+) T cells are activated in peripheral blood and accumulate in cerebrospinal fluid from HAM/TSP patients.

    Science.gov (United States)

    Greten, T F; Slansky, J E; Kubota, R; Soldan, S S; Jaffee, E M; Leist, T P; Pardoll, D M; Jacobson, S; Schneck, J P

    1998-06-23

    Human T lymphotropic virus type 1 (HTLV-1) -associated myelopathy/tropic spastic paraparesis is a demyelinating inflammatory neurologic disease associated with HTLV-1 infection. HTLV-1 Tax11-19-specific cytotoxic T cells have been isolated from HLA-A2-positive patients. We have used a peptide-loaded soluble HLA-A2-Ig complex to directly visualize HTLV-1 Tax11-19-specific T cells from peripheral blood and cerebrospinal fluid without in vitro stimulation. Five of six HTLV-1-associated myelopathy/tropic spastic paraparesis patients carried a significant number (up to 13.87%) of CD8(+) lymphocytes specific for the HTLV-1 Tax11-19 peptide in their peripheral blood, which were not found in healthy controls. Simultaneous comparison of peripheral blood and cerebrospinal fluid from one patient revealed 2.5-fold more Tax11-19-specific T cells in the cerebrospinal fluid (23.7% vs. 9.4% in peripheral blood lymphocyte). Tax11-19-specific T cells were seen consistently over a 9-yr time course in one patient as far as 19 yrs after the onset of clinical symptoms. Further analysis of HTLV-1 Tax11-19-specific CD8(+) T lymphocytes in HAM/TSP patients showed different expression patterns of activation markers, intracellular TNF-alpha and gamma-interferon depending on the severity of the disease. Thus, visualization of antigen-specific T cells demonstrates that HTLV-1 Tax11-19-specific CD8(+) T cells are activated, persist during the chronic phase of the disease, and accumulate in cerebrospinal fluid, showing their pivotal role in the pathogenesis of this neurologic disease.

  8. Dark adaptation during transient hyperglycemia in type 2 diabetes

    DEFF Research Database (Denmark)

    Holfort, Stig Kraglund; Jackson, Gregory R; Larsen, Michael

    2010-01-01

    adaptometry was measured in one eye, chosen at random, using a computer-controlled dark adaptometer. Dark adaptation and capillary blood glucose were measured at baseline and 80 minutes into the OGTT/fasting test. Blood glucose remained stable throughout the examination in the 12 fasting subjects, whereas......It was the purpose of the present study to examine dark adaptation in subjects with type 2 diabetes during transient hyperglycemia. Twenty-four subjects with type 2 diabetes and minimal diabetic retinopathy were randomized to undergo an oral glucose tolerance test (OGTT) or to remain fasting. Dark...... glycemia increased in the 12 OGTT subjects, from 8.6±2.1 at baseline to 21.1±3.6 mM after 80 min. In the OGTT group, four out of seven subjects with delayed dark adaptation at baseline reached normal values during hyperglycemia. All examined aspects of rod adaptation were accelerated by hyperglycemia (time...

  9. Signal void dots on T2-weighted brain MR images in patients with hypertensive intracerebral hemorrhage : Its nature and clinical significance

    International Nuclear Information System (INIS)

    Kim, Sang Joon; Yoo, Dong Soo; Kim, Seung Chul; Kim, Tae Hoon; Kim, Jae Seung; Kim, Jae Il

    1997-01-01

    To describe the signal void dots found on T2-weighted magnetic resonance (MR) images of the brain in hypertensive patients. Conventional T2-weighted MR images of 11 patients with hypertensive intracerebral hemorrhage (ICH), 14 with lacunar infarction and 11 comprising a normal control group aged over 60 were analyzed with regard to the presence, location, number and size of signal void dots. We also evaluated their relationship to hypertension. We performed time-of-flight or phase contrast MR angiography, gradient echo pulse sequences, or conventional cerebral angiography in some hypertensive ICH patients and compared them with corresponding T2-weighted images. Signal void dots were found in all patients with hypertensive ICH. Six of 14 patients with lacunar infarction showed these dots;all six suffered from hypertension. The dots were located in the thalami, pons and basal ganglia, and were measured as 1 to 4mm in diameter, mostly 2mm;they looked larger on gradient echo images. In the normal control group there were no signal void dots, and on MR or conventional angiography, no vascular ectasia was noted at the site corresponding to the signal void dots. Signal void dots were not considered to be part of the normal aging process, but appeared to be closely related to hypertension and ICH. The dots were thought to be due to the susceptibility effect of blood degradation product rather than to flow artifact or enlarged vessels. The thrombosed microaneurysm with or without surrounding microleakage of blood may explain the nature of signal void dots on T2-weighted images of hypertensive brain

  10. Blood lead levels and bone turnover with weight reduction in women

    OpenAIRE

    RIEDT, CLAUDIA S.; BUCKLEY, BRIAN T.; BROLIN, ROBERT E.; AMBIA-SOBHAN, HASINA; RHOADS, GEORGE G.; SHAPSES, SUE A.

    2008-01-01

    High bone turnover states are known to raise blood lead levels (BPb). Caloric restriction will increase bone turnover, yet it remains unknown if weight reduction increases BPb due to mobilization of skeletal stores. We measured whole blood Pb levels (206Pb) by inductively coupled plasma mass spectrometry in 73 women (age 24–75 years; BMI 23– 61 kg/m2) before and after 6 months of severe weight loss (S-WL), moderate weight loss (M-WL), or weight maintenance (WM). Baseline BPb levels were relat...

  11. The coadjoint orbit spaces of Diff(S1) and Teichmueller spaces

    International Nuclear Information System (INIS)

    Nag, S.; Verjovsky, A.

    1989-09-01

    Precisely two of the homogeneous spaces that appear as coadjoint orbits of the group of string reparametrizations (Diff (S 1 )) carry in a natural way the structure of infinite dimensional, holomorphically homogeneous complex analytic Kaehler manifolds. These are N = Diff (S 1 )/Rot (S 1 ) and M = Diff (S 1 )/Moeb (S 1 ). Note that N is a holomorphic disc fiber space over M. Now, M can be naturally considered as embedded in the classical universal Teichmueller space T(1), simply by noting that a diffeomorphism of S 1 is a quasisymmetric homeomorphism. T(1) is itself a homomorphically homogeneous complex Banach manifold. We prove in the first part of the paper that the inclusion of M in T(1) is complex analytic. In the latter portion of this paper it is shown that the unique homogeneous Kaehler metric carried by M = Diff (S 1 )/SL(2, R) induces precisely the Weil-Petersson metric on the Teichmueller space. This is via our identification of M as a holomorphic submanifold of universal Teichmueller space. Now recall that every Teichmueller space T(G) of finite or infinite dimension is contained canonically and holomorphically within T(1). Our computations allow us also to prove that every T(G), G any infinite Fuchsian group, projects out of M transversely. This last assertion is related to the ''fractal'' nature of G-invariant quasicircles, and to Mostow rigidity on the line. Our results thus connect the loop space approach to bosonic string theory with the sumover moduli (Polyakov path integral) approach. (author). 21 refs

  12. Cord Blood Lysophosphatidylcholine 16: 1 is Positively Associated with Birth Weight

    Directory of Open Access Journals (Sweden)

    Yong-Ping Lu

    2018-01-01

    Full Text Available Background/Aims: Impaired birth outcomes, like low birth weight, have consistently been associated with increased disease susceptibility to hypertension in later life. Alterations in the maternal or fetal metabolism might impact on fetal growth and influence birth outcomes. Discerning associations between the maternal and fetal metabolome and surrogate parameters of fetal growth could give new insight into the complex relationship between intrauterine conditions, birth outcomes, and later life disease susceptibility. Methods: Using flow injection tandem mass spectrometry, targeted metabolomics was performed in serum samples obtained from 226 mother/child pairs at delivery. Associations between neonatal birth weight and concentrations of 163 maternal and fetal metabolites were analyzed. Results: After FDR adjustment using the Benjamini-Hochberg procedure lysophosphatidylcholines (LPC 14: 0, 16: 1, and 18: 1 were strongly positively correlated with birth weight. In a stepwise linear regression model corrected for established confounding factors of birth weight, LPC 16: 1 showed the strongest independent association with birth weight (CI: 93.63 - 168.94; P = 6.94×10-11 . The association with birth weight was stronger than classical confounding factors such as offspring sex (CI: -258.81- -61.32; P = 0.002 and maternal smoking during pregnancy (CI: -298.74 - -29.51; P = 0.017. Conclusions: After correction for multiple testing and adjustment for potential confounders, LPC 16: 1 showed a very strong and independent association with birth weight. The underlying molecular mechanisms linking fetal LPCs with birth weight need to be addressed in future studies.

  13. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  14. Constraints on Λ(t)-cosmology with power law interacting dark sectors

    International Nuclear Information System (INIS)

    Poitras, Vincent

    2012-01-01

    Motivated by the cosmological constant and the coincidence problems, we consider a cosmological model where the cosmological constant Λ 0 is replaced by a cosmological term Λ(t) which is allowed to vary in time. More specifically, we are considering that this dark energy term interacts with dark matter through the phenomenological decay law ρ-dot Λ = −Qρ Λ n . We have constrained the model for the range n element of [0,10] using various observational data (SNeIa, GRB, CMB, BAO, OHD), emphasizing the case where n = 3/2. This case is the only one where the late-time value for the ratio of dark energy density and matter energy density ρ Λ /ρ m is constant, which could provide an interesting explanation to the coincidence problem. We obtain strong limits on the model parameters which however exclude the region where the coincidence or the cosmological constant problems are significantly ameliorated

  15. Interacting diffusive unified dark energy and dark matter from scalar fields

    Energy Technology Data Exchange (ETDEWEB)

    Benisty, David; Guendelman, E.I. [Ben Gurion University of the Negev, Department of Physics, Beersheba (Israel)

    2017-06-15

    Here we generalize ideas of unified dark matter-dark energy in the context of two measure theories and of dynamical space time theories. In two measure theories one uses metric independent volume elements and this allows one to construct unified dark matter-dark energy, where the cosmological constant appears as an integration constant associated with the equation of motion of the measure fields. The dynamical space-time theories generalize the two measure theories by introducing a vector field whose equation of motion guarantees the conservation of a certain Energy Momentum tensor, which may be related, but in general is not the same as the gravitational Energy Momentum tensor. We propose two formulations of this idea: (I) by demanding that this vector field be the gradient of a scalar, (II) by considering the dynamical space field appearing in another part of the action. Then the dynamical space time theory becomes a theory of Diffusive Unified dark energy and dark matter. These generalizations produce non-conserved energy momentum tensors instead of conserved energy momentum tensors which leads at the end to a formulation of interacting DE-DM dust models in the form of a diffusive type interacting Unified dark energy and dark matter scenario. We solved analytically the theories for perturbative solution and asymptotic solution, and we show that the ΛCDM is a fixed point of these theories at large times. Also a preliminary argument as regards the good behavior of the theory at the quantum level is proposed for both theories. (orig.)

  16. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  17. Quantitative retinal and choroidal blood flow during light, dark adaptation and flicker light stimulation in rats using fluorescent microspheres.

    Science.gov (United States)

    Shih, Yen-Yu I; Wang, Lin; De La Garza, Bryan H; Li, Guang; Cull, Grant; Kiel, Jeffery W; Duong, Timothy Q

    2013-02-01

    The present study aimed to quantify retinal and choroidal blood flow (BF) during light, dark adaptation and flicker light stimulation using the microsphere technique. Adult male Sprague-Dawley rats were anesthetized with isoflurane. Eyes were dark (Group I, n = 8), light (Group II, n = 8) adapted or stimulated with 10 Hz flicker light (Group III, n = 10). Retinal and choroidal BF were measured by a previously established method, using a mixture of 8 µm yellow-green and 10 µm red fluorescent microspheres. The microspheres were counted ex vivo in the dissected retina and choroid and in the reference arterial blood under a fluorescent microscope. The choroidal BF was 64.8 ± 29 µl/min (mean ± SD) during dark adaptation, not significantly different from that during light adaptation (66.0 ± 17.8 µl/min). The retinal BF was 13.5 ± 3.2 µl/min during 10 Hz flickering light stimulation, significantly higher than that during dark adaptation in the control fellow eyes (9.9 ± 2.9 µl/min). The choroidal BF values were not statistically different between flicker stimulation and dark adaptation. Retinal BF was 11.6 ± 2.9 µl/min during light adaptation. Dark adaptation did not increase retinal BF (Group I, 8.2 ± 2.4 µl/min; Group II, 9.9 ± 2.9 µl/min). These findings argue against a dark-induced or flicker-induced functional hyperemia in the choroid as a result of the demands of the outer retina. Retinal BF was not higher during dark adaptation. Our data support the conclusion that the inner retina has a higher energy demand in flicker conditions relative to dark.

  18. In hypertrophic cardiomyopathy reduction of relative resting myocardial blood flow is related to late enhancement, T2-signal and LV wall thickness.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available To quantify resting myocardial blood flow (MBF in the left ventricular (LV wall of HCM patients and to determine the relationship to important parameters of disease: LV wall thickness, late gadolinium enhancement (LGE, T2-signal abnormalities (dark and bright signal, LV outflow tract obstruction and age.Seventy patients with proven HCM underwent cardiac MRI. Absolute and relative resting MBF were calculated from cardiac perfusion MRI by using the Fermi function model. The relationship between relative MBF and LV wall thickness, T2-signal abnormalities (T2 dark and T2 bright signal, LGE, age and LV outflow gradient as determined by echocardiography was determined using simple and multiple linear regression analysis. Categories of reduced and elevated perfusion in relation to non- or mildly affected reference segments were defined, and T2-signal characteristics and extent as well as pattern of LGE were examined. Statistical testing included linear and logistic regression analysis, unpaired t-test, odds ratios, and Fisher's exact test.804 segments in 70 patients were included in the analysis. In a simple linear regression model LV wall thickness (p<0.001, extent of LGE (p<0.001, presence of edema, defined as focal T2 bright signal (p<0.001, T2 dark signal (p<0.001 and age (p = 0.032 correlated inversely with relative resting MBF. The LV outflow gradient did not show any effect on resting perfusion (p = 0.901. Multiple linear regression analysis revealed that LGE (p<0.001, edema (p = 0.026 and T2 dark signal (p = 0.019 were independent predictors of relative resting MBF. Segments with reduced resting perfusion demonstrated different LGE patterns compared to segments with elevated resting perfusion.In HCM resting MBF is significantly reduced depending on LV wall thickness, extent of LGE, focal T2 signal abnormalities and age. Furthermore, different patterns of perfusion in HCM patients have been defined, which may represent different stages of

  19. Coupling q-Deformed Dark Energy to Dark Matter

    Directory of Open Access Journals (Sweden)

    Emre Dil

    2016-01-01

    Full Text Available We propose a novel coupled dark energy model which is assumed to occur as a q-deformed scalar field and investigate whether it will provide an expanding universe phase. We consider the q-deformed dark energy as coupled to dark matter inhomogeneities. We perform the phase-space analysis of the model by numerical methods and find the late-time accelerated attractor solutions. The attractor solutions imply that the coupled q-deformed dark energy model is consistent with the conventional dark energy models satisfying an acceleration phase of universe. At the end, we compare the cosmological parameters of deformed and standard dark energy models and interpret the implications.

  20. Blood troponin levels in acute cardiac events depends on space weather activity components (a correlative study).

    Science.gov (United States)

    Stoupel, Eliiyahu; Radishauskas, Richardas; Bernotiene, Gailute; Tamoshiunas, Abdonas; Virvichiute, Daiva

    2018-02-05

    Many biological processes are influenced by space weather activity components such as solar activity (SA), geomagnetic activity (GMA) and cosmic ray activity (CRA). Examples are total mortality, acute myocardial infarction (AMI), stroke (cerebrovascular accident), sudden cardiac death, some congenital maladies (congenital heart disease and Down syndrome), many events in neonatology, ophtalmology, blood pressure regulation, blood coagulation, inflammation, etc. The aim of this study was to check if the level of blood troponins (Tns) - markers of myocardial damage and recognized components of modern description of AMI - is connected with the mentioned space weather parameters. Patients admitted to a 3000-bed tertiary university hospital in Kaunas, Lithuania, with suspected AMI were the object of the study. Data for the time between 2008 and 2013 - 72 consecutive months - were studied. Of the patients, 1896 (1398 male, 498 female) had elevated troponin I (Tn I) or troponin T (Tn T, sensitive Tn) levels. Normal values were 0.00-0.03 ng/mL for Tn I and 0.00-14.00 ng/mL for Tn T. Monthly means and standard deviation of Tn I and Tn T were compared with monthly markers of SA, GMA and CRA. Pearson correlation coefficients and their probabilities were established (in addition to the consecutive graphs of both comparing physical and biological data). The cosmophysical data came from space service institutions in the United States, Russia and Finland. AMI was diagnosed in 1188 patients (62.66%), and intermediate coronary syndrome in 698 patients (36.81%). There were significant links of the Tn blood levels with four SA indices and CRA (neutron activity in imp/min); there was no significant correlation with GMA indices Ap and Cp (p=0.27 and p=0.235). Tn T levels significantly correlated with the GMA indices and not with the SA and CRA levels (Ap: r=0.77, p=0.0021; Cp: r=0.729, p=0.0047). First, the monthly level of blood Tn I in ACS is significantly correlated with the indices

  1. A hematopoietic contribution to microhemorrhage formation during antiviral CD8 T cell-initiated blood-brain barrier disruption

    Directory of Open Access Journals (Sweden)

    Johnson Holly L

    2012-03-01

    Full Text Available Abstract Background The extent to which susceptibility to brain hemorrhage is derived from blood-derived factors or stromal tissue remains largely unknown. We have developed an inducible model of CD8 T cell-initiated blood-brain barrier (BBB disruption using a variation of the Theiler's murine encephalomyelitis virus (TMEV model of multiple sclerosis. This peptide-induced fatal syndrome (PIFS model results in severe central nervous system (CNS vascular permeability and death in the C57BL/6 mouse strain, but not in the 129 SvIm mouse strain, despite the two strains' having indistinguishable CD8 T-cell responses. Therefore, we hypothesize that hematopoietic factors contribute to susceptibility to brain hemorrhage, CNS vascular permeability and death following induction of PIFS. Methods PIFS was induced by intravenous injection of VP2121-130 peptide at 7 days post-TMEV infection. We then investigated brain inflammation, astrocyte activation, vascular permeability, functional deficit and microhemorrhage formation using T2*-weighted magnetic resonance imaging (MRI in C57BL/6 and 129 SvIm mice. To investigate the contribution of hematopoietic cells in this model, hemorrhage-resistant 129 SvIm mice were reconstituted with C57BL/6 or autologous 129 SvIm bone marrow. Gadolinium-enhanced, T1-weighted MRI was used to visualize the extent of CNS vascular permeability after bone marrow transfer. Results C57BL/6 and 129 SvIm mice had similar inflammation in the CNS during acute infection. After administration of VP2121-130 peptide, however, C57BL/6 mice had increased astrocyte activation, CNS vascular permeability, microhemorrhage formation and functional deficits compared to 129 SvIm mice. The 129 SvIm mice reconstituted with C57BL/6 but not autologous bone marrow had increased microhemorrhage formation as measured by T2*-weighted MRI, exhibited a profound increase in CNS vascular permeability as measured by three-dimensional volumetric analysis of

  2. Integrability of geodesics and action-angle variables in Sasaki-Einstein space T{sup 1,1}

    Energy Technology Data Exchange (ETDEWEB)

    Visinescu, Mihai [National Institute of Physics and Nuclear Engineering, Department Theoretical Physics, Magurele, Bucharest (Romania)

    2016-09-15

    We briefly describe the construction of Staekel-Killing and Killing-Yano tensors on toric Sasaki-Einstein manifolds without working out intricate generalized Killing equations. The integrals of geodesic motions are expressed in terms of Killing vectors and Killing-Yano tensors of the homogeneous Sasaki-Einstein space T{sup 1,1}. We discuss the integrability of geodesics and construct explicitly the action-angle variables. Two pairs of frequencies of the geodesic motions are resonant giving way to chaotic behavior when the system is perturbed. (orig.)

  3. The Helmholtz Hierarchy: Phase Space Statistics of Cold Dark Matter

    OpenAIRE

    Tassev, Svetlin

    2010-01-01

    We present a new formalism to study large-scale structure in the universe. The result is a hierarchy (which we call the "Helmholtz Hierarchy") of equations describing the phase space statistics of cold dark matter (CDM). The hierarchy features a physical ordering parameter which interpolates between the Zel'dovich approximation and fully-fledged gravitational interactions. The results incorporate the effects of stream crossing. We show that the Helmholtz hierarchy is self-consistent and obeys...

  4. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  5. Weight Status and High Blood Pressure Among Low-Income African American Men

    Science.gov (United States)

    Bruce, Marino A.; Beech, Bettina M.; Edwards, Christopher L.; Sims, Mario; Scarinci, Isabel; Whitfield, Keith E.; Gilbert, Keon; Crook, Errol D.

    2016-01-01

    Obesity is a biological risk factor or comorbidity that has not received much attention from scientists studying hypertension among African American men. The purpose of this study was to examine the relationship between weight status and high blood pressure among African American men with few economic resources. The authors used surveillance data collected from low-income adults attending community- and faith-based primary care clinics in West Tennessee to estimate pooled and group-specific regression models of high blood pressure. The results from group-specific logistic regression models indicate that the factors associated with hypertension varied considerably by weight status. This study provides a glimpse into the complex relationship between weight status and high blood pressure status among African American men. Additional research is needed to identify mechanisms through which excess weight affects the development and progression of high blood pressure. PMID:20937738

  6. Dark and photoreactivity of 4'-aminomethyl-4,5',8-trimethylpsoralen with T7 phage.

    Science.gov (United States)

    Tóth, K; Csik, G; Rontó, G

    1990-04-15

    The dark and photoreactions of 4'-aminomethyl-4,5',8-trimethylpsoralen (AMT) with T7 phage were investigated from biological and structural points of view. The dark reaction leads to the structural destabilization of the double helix of the DNA as is shown by optical melting measurements. The genotoxicity of AMT in the dark is comparable with that of known genotoxic drugs as determined by phage inactivation. The photoreaction with UVA light leads to the formation of mono- and di-adducts depending on the wavelength and dose used. Mono- and di-adducts influence DNA stability differently; biologically both types of adducts are genotoxic as measured by action spectra.

  7. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    Science.gov (United States)

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  8. 46 CFR 32.40-35 - Hospital space-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Hospital space-T/ALL. 32.40-35 Section 32.40-35 Shipping... REQUIREMENTS Accommodations for Officers and Crew § 32.40-35 Hospital space—T/ALL. (a) Each vessel which in the... crew of 12 or more, must be provided with a hospital space. This space must be situated with due regard...

  9. Persistence of solutions to nonlinear evolution equations in weighted Sobolev spaces

    Directory of Open Access Journals (Sweden)

    Xavier Carvajal Paredes

    2010-11-01

    Full Text Available In this article, we prove that the initial value problem associated with the Korteweg-de Vries equation is well-posed in weighted Sobolev spaces $mathcal{X}^{s,heta}$, for $s geq 2heta ge 2$ and the initial value problem associated with the nonlinear Schrodinger equation is well-posed in weighted Sobolev spaces $mathcal{X}^{s,heta}$, for $s geq heta geq 1$. Persistence property has been proved by approximation of the solutions and using a priori estimates.

  10. Protective Misperception? Prospective Study of Weight Self-Perception and Blood Pressure in Adolescents With Overweight and Obesity.

    Science.gov (United States)

    Unger, Emily S; Kawachi, Ichiro; Milliren, Carly E; Sonneville, Kendrin R; Thurston, Idia B; Gooding, Holly C; Richmond, Tracy K

    2017-06-01

    Underestimating one's weight is often seen as a barrier to weight loss. However, recent research has shown that weight underperception may be beneficial, with lower future weight gain and fewer depressive symptoms. Here, we examine the relationship between adolescent weight underperception and future blood pressure. Using data from the National Longitudinal Study of Adolescent to Adult Health, we obtained a nationally representative sample of 2,463 adolescents with overweight and obesity (students in grades 8-12 in 1996). We used multivariable linear regression to prospectively examine the relationship between weight self-perception in adolescence and blood pressure in adulthood (year 2008; follow-up rate 80.3%), controlling for age, gender, race/ethnicity, smoking, alcohol consumption, education level, household income, and body mass index. Additional analyses were stratified by gender and race/ethnicity. Youth with overweight/obesity who underperceived their weight had lower blood pressure in adulthood than those who perceived themselves to be overweight. The decrease in systolic blood pressure was -2.5 mm Hg (95% confidence interval: -4.3, -0.7; p = .006). Although the interaction by gender was statistically insignificant (p = .289), important differences appeared upon stratification by gender. Young men showed no significant difference in adult blood pressure related to weight self-perception. Conversely, in young women, weight underperception was associated with an average decrease in systolic blood pressure of -4.3 mm Hg (95% confidence interval: -7.0, -1.7; p = .002). Contrary to conventional wisdom, weight underperception is associated with improved health markers in young women. The observed differences in blood pressure are clinically relevant in magnitude, and interventions to correct weight underperception should be re-examined for unintended consequences. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc

  11. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    2002-03-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  12. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi

    2002-01-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  13. Temporal and spatial characteristics of the area at risk investigated using computed tomography and T1-weighted magnetic resonance imaging

    DEFF Research Database (Denmark)

    van der Pals, Jesper; Hammer-Hansen, Sophia; Nielles-Vallespin, Sonia

    2015-01-01

    AIMS: Cardiovascular magnetic resonance (CMR) imaging can measure the myocardial area at risk (AAR), but the technique has received criticism for inadequate validation. CMR commonly depicts an AAR that is wider than the infarct, which in turn would require a lateral perfusion gradient within...... and fluorescent microparticle pathology were used to investigate the AAR in a canine model (n = 10) of ischaemia and reperfusion. AAR size by CMR correlated well with CT (R(2) = 0.80), microsphere blood flow (R(2) = 0.80), and pathology (R(2) = 0.74) with good limits of agreement [-0.79 ± 4.02% of the left.......05 ± 0.02 mL/g/min, lateral vs. core, P = 0.001). The transmural extent of MI was lower in the lateral portion of the AAR than the core (28.2 ± 10.2 vs. 17.4 ± 8.4% of the wall, P = 0.001). CONCLUSION: T1-weighted CMR accurately quantifies size of the AAR with excellent agreement compared with three...

  14. Comparison between FLAIR images and T2-weighted fast spin-echo images of cerebral territory and lacunar infarction

    International Nuclear Information System (INIS)

    Paeng, Mi Hye; Choi, Hye-Young; Lim, Soo Mee; Lee, Jung Sik

    2003-01-01

    To assess the significance of fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) imaging in the diagnosis of intracranial infarctions and to find out differential points between central lacunar infarctions and perivascular spaces. We consecutively selected 25 cases of territorial infarction in 20 patients, 37 cases of central infarction in 40 patients, and 30 patients with perivascular space. Signal intensity and lesion conspicuity were analyzed and compared between FLAIR and FSE T2-weighted images, and differences in signal intensity between central infarction and perivascular spaces were determined. Lesion conspicuity for FLAIR was better than for T2-weighted images in 12 and 15, worse in 4 and 24, and similar in 9 and 16 of territorial and central infarctions, respectively. In nine cases of territorial and one case of central infarction, there was associated hemorrhage. At FLAIR imaging, perivascular spaces showed a fine round low signal without a peripheral high signal rim in 17 patients but no demonstrable signals in 15. Differential diagnosis of perivascular spaces and central infarction was thus not difficult. FLAIR MRI was useful in the diagnosis of infarctions and in differentiating between central small lacular infarctions and perivascular spaces

  15. Walnut consumption in a weight reduction intervention: effects on body weight, biological measures, blood pressure and satiety.

    Science.gov (United States)

    Rock, Cheryl L; Flatt, Shirley W; Barkai, Hava-Shoshana; Pakiz, Bilge; Heath, Dennis D

    2017-12-04

    Dietary strategies that help patients adhere to a weight reduction diet may increase the likelihood of weight loss maintenance and improved long-term health outcomes. Regular nut consumption has been associated with better weight management and less adiposity. The objective of this study was to compare the effects of a walnut-enriched reduced-energy diet to a standard reduced-energy-density diet on weight, cardiovascular disease risk factors, and satiety. Overweight and obese men and women (n = 100) were randomly assigned to a standard reduced-energy-density diet or a walnut-enriched (15% of energy) reduced-energy diet in the context of a behavioral weight loss intervention. Measurements were obtained at baseline and 3- and 6-month clinic visits. Participants rated hunger, fullness and anticipated prospective consumption at 3 time points during the intervention. Body measurements, blood pressure, physical activity, lipids, tocopherols and fatty acids were analyzed using repeated measures mixed models. Both study groups reduced body weight, body mass index and waist circumference (time effect p weight was -9.4 (0.9)% vs. -8.9 (0.7)% (mean [SE]), for the standard vs. walnut-enriched diet groups, respectively. Systolic blood pressure decreased in both groups at 3 months, but only the walnut-enriched diet group maintained a lower systolic blood pressure at 6 months. The walnut-enriched diet group, but not the standard reduced-energy-density diet group, reduced total cholesterol and low-density lipoprotein cholesterol (LDL-C) at 6 months, from 203 to 194 mg/dL and 121 to 112 mg/dL, respectively (p weight loss that is comparable to a standard reduced-energy-density diet in the context of a behavioral weight loss intervention. Although weight loss in response to both dietary strategies was associated with improvements in cardiovascular disease risk factors, the walnut-enriched diet promoted more favorable effects on LDL-C and systolic blood pressure. The trial

  16. Changes in myocardial blood flow and S-T segment elevation following coronary artery occlusion in dogs

    International Nuclear Information System (INIS)

    Smith, H.J.; Singh, B.N.; Norris, R.M.; John, M.B.; Hurley, P.J.

    1975-01-01

    The relationship between regional blood flow and epicardial S-T segment elevation was studied in 26 open-chest anesthetized dogs with left anterior coronary artery ligations. Changes in myocardial blood flow, measured with 15 +- 5 μ (diameter) microspheres labeled with 141 Ce, 85 Sr, and 169 Yb, were correlated with summated S-T segment elevations 15 minutes, 1 hour, and 2 hours after coronary artery occlusion. In normal areas, myocardial blood flow was 113 +- 5 ml/min 100 g -1 and summated S-T segment elevation was 0.3 +- 0.2 mv. Fifteen minutes after coronary artery occlusion in 26 dogs, S-T segment elevation was 5.7 +- 0.7 mv over the center of the infarct and myocardial blood flow was 10 +- 1 ml/min 100 g -1 ; over the border zone, myocardial blood flow was 63 +- 4 ml/min 100 g -1 and S-T segment elevation was 3.1 +- 0.1 mv. One third of the areas with a myocardial blood flow of 10 ml/min 100 g -1 or less had no S-T segment elevation. In the center and border zones of the infarct in 9 dogs, myocardial blood flow increased from 11 +- 2 and 67 +- 8 ml/min 100 g -1 15 minutes after occlusion to 20 +- 4 and 84 +- 12 ml/min 100 g -1 , respectively, 2 hours after coronary artery occlusion. These increases were not associated with a significant reduction in summated S-T segment elevation. The results do not suggest a simple quantitative relationship between epicardial S-T segment elevation and myocardial blood flow following acute coronary artery occlusion

  17. Brightness and darkness as perceptual dimensions

    NARCIS (Netherlands)

    Vladusich, T.; Lucassen, M.P.; Cornelissen, F.W.

    2007-01-01

    A common-sense assumption concerning visual perception states that brightness and darkness cannot coexist at a given spatial location. One corollary of this assumption is that achromatic colors, or perceived grey shades, are contained in a one-dimensional (1-D) space varying from bright to dark. The

  18. Angiographically occult vascular malformation of the brain: MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Patel, S.C.; Sanders, W.P.; Fuentes, J.; Haggar, A.M.; Mehta, B.A.; Boulos, R.S.; Froelich, J.W.

    1986-01-01

    MR imaging was performed in nine patients with 12 angiographically occult arteriovenous malformations using a 1.5-T superconducting magnet; four additional patients were imaged using a 0.3-T system. All images were reviewed in conjunction with CT scans. The following observations were made. (1) Eleven of 14 supratentorial lesions were located at the junction of gray and white matter. (2) Exclusing acute hemorrhage, only two lesions displayed mild mass effect. (3) All lesions displayed central foci of high signal intensity, probably representing subacute hemorrhage. (4) All lesions but one showed a peripheral rim of low signal intensity which progressively lost signal with increasing T2 weighting. This most likely represents iron-containing hemosiderin deposition. (5) Lesions were best demonstrated with long repetition times and moderate T2 weighting (TR = 2,500 msec, TE = 25-100 msec). (6) All lesions but one were hyperdense on non-contrast-enhanced CT, although only three had unequivocal calcification. The possibility of hyperdensity due to blood or iron deposition is discussed

  19. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Science.gov (United States)

    Huang, Meiyan; Yang, Wei; Wu, Yao; Jiang, Jun; Gao, Yang; Chen, Yang; Feng, Qianjin; Chen, Wufan; Lu, Zhentai

    2014-01-01

    This study aims to develop content-based image retrieval (CBIR) system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR) images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW) model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML) is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor). Using the BoVW model with partition learning, the mean average precision (mAP) of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  20. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Directory of Open Access Journals (Sweden)

    Meiyan Huang

    Full Text Available This study aims to develop content-based image retrieval (CBIR system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor. Using the BoVW model with partition learning, the mean average precision (mAP of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  1. Diffusion-weighted echo planar imaging in patients with recent myocardial infarction

    International Nuclear Information System (INIS)

    Deux, Jean-Francois; Maatouk, Mezri; Luciani, Alain; Lenczner, Gregory; Mayer, Julie; Kobeiter, Hicham; Rahmouni, Alain; Vignaud, Alexandre; Lim, Pascal; Dubois-Rande, Jean-Luc

    2011-01-01

    To evaluate a diffusion-weighted (DW) black blood MR sequence for the detection of myocardium signal abnormalities in patients with recent myocardial infarction (MI). A DW black blood EPI sequence was acquired at 1.5 T in 12 patients with recent MI. One slice per patient was acquired with b = 0 and b = 50 s/mm 2 . A standard short tau inversion recovery (STIR) T2-weighted sequence was acquired at the same level. Viability was assessed with delayed-enhancement sequences. Images were analyzed qualitatively and quantitatively. A non parametric Wilcoxon test was used for statistical analysis, with a significance level of P <.05. The mean quality of blood suppression was higher on DW EPI images than on STIR T2-weighted images (3.9 ± 0.3 and 3.0 ± 0.7, respectively; P = 0.01). Myocardial high signal areas were detected in respectively 100% (12/12) and 67% (8/12) of the patients on DW EPI and STIR T2-weighted images. The four patients (33%) with false-negative STIR T2 findings all had high signal areas on DW EPI images corresponding to the location of the MI on the delayed-enhanced images. DW EPI sequences are a feasible alternative to standard STIR T2-weighted sequences for detecting myocardium high signal areas in patients with recent MI. (orig.)

  2. Meta-regression analysis to evaluate relationships between maternal blood levels of placentation biomarkers and low delivery weight.

    Science.gov (United States)

    Goto, Eita

    2018-05-03

    Caution is required for women at increased risk of low neonatal delivery weight. To evaluate relationships between maternal placentation biomarkers and the odds of low delivery weight. Databases including PubMed/MEDLINE were searched up to May 2017 using keywords involving biomarker names and "low birthweight." English language studies providing true- and false-positive, and true- and false-negative results of low delivery weight classified by maternal blood levels of placentation biomarkers (in units of multiple of the mean [MoM]) were included. Coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood placentation biomarkers, and those adjusted for race, sampling period, and/or study quality were calculated. Adjusted coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood levels of α-fetoprotein (AFP) and β-human chorionic gonadotropin (β-hCG) were significantly greater than 0 (both Plow delivery weight. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Drugs as habitable planets in the space of dark chemical matter.

    Science.gov (United States)

    Siramshetty, Vishal B; Preissner, Robert

    2018-03-01

    A recent study demonstrated antifungal activity of dark chemical matter (DCM) compounds that were otherwise inactive in more than 100 HTS assays. These compounds were proposed to possess unique activity and 'clean' safety profiles. Here, we present an outlook of the promiscuity and safety of these compounds by retrospectively comparing their chemical and biological spaces with those of drugs. Significant amounts of marketed drugs (16%), withdrawn drugs (16.5%) and natural compounds (3.5%) share structural identity with DCM. Compound promiscuity assessment indicates that dark matter compounds could potentially interact with multiple biological targets. Further, thousands of DCM compounds showed presence of frequent-hitting pan-assay interference compound (PAINS) substructures. In light of these observations, filtering these compounds from screening libraries can be an irrevocable loss. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The Effect of Ramadan Fasting and Weight-Lifting Training on Plasma Volume, Glucose and Lipids Profile of Male Weight-Lifters

    Directory of Open Access Journals (Sweden)

    Seyed Morteza Tayebi

    Full Text Available Objective(sThe purpose of the present study was to evaluate the effect of Ramadan fasting and weight-lifting training on plasma volume, glucose, and lipids profile of male weight-lifter.Materials and MethodsForty male weight-lifters were recruited and divided into 4 groups (n=10 each and as the following groups: control (C, fasting (F, training (T and fasting-training (F-T. The T and F-T groups performed weight-lifting technique trainings and hypertrophy body building (3 sessions/week, 90 min/session. All subjects were asked to complete a medical examination as well as a medical questionnaire to ensure that they were not taking any medication, were free of cardiac, respiratory, renal, and metabolic diseases, and were not using steroids. Blood samples were taken at 24 hr before and 24 hr after one month of fasting and weight-lifting exercise. The plasma volume, fasting blood sugar (FBS, lipid profiles, and lipoproteins were analyzed in blood samples. ResultsBody weight and plasma volume showed significant (P< 0.05 decrease and increase in the F group (P< 0.05 respectively. Also, a significant reduction was observed in F-T group body weight (P< 0.01. A significant increase was found in FBS level of F group (P< 0.05. The lipid profiles and lipoproteins didn’t change significantly in C, F, T and the F-T groups.ConclusionThe effect of Ramadan fasting on body weight and plasma volumes may be closely related to the nutritional diet or biochemical response to fasting.

  5. EDITORIAL: Focus on Dark Matter and Particle Physics

    Science.gov (United States)

    Aprile, Elena; Profumo, Stefano

    2009-10-01

    The quest for the nature of dark matter has reached a historical point in time, with several different and complementary experiments on the verge of conclusively exploring large portions of the parameter space of the most theoretically compelling particle dark matter models. This focus issue on dark matter and particle physics brings together a broad selection of invited articles from the leading experimental and theoretical groups in the field. The leitmotif of the collection is the need for a multi-faceted search strategy that includes complementary experimental and theoretical techniques with the common goal of a sound understanding of the fundamental particle physical nature of dark matter. These include theoretical modelling, high-energy colliders and direct and indirect searches. We are confident that the works collected here present the state of the art of this rapidly changing field and will be of interest to both experts in the topic of dark matter as well as to those new to this exciting field. Focus on Dark Matter and Particle Physics Contents DARK MATTER AND ASTROPHYSICS Scintillator-based detectors for dark matter searches I S K Kim, H J Kim and Y D Kim Cosmology: small-scale issues Joel R Primack Big Bang nucleosynthesis and particle dark matter Karsten Jedamzik and Maxim Pospelov Particle models and the small-scale structure of dark matter Torsten Bringmann DARK MATTER AND COLLIDERS Dark matter in the MSSM R C Cotta, J S Gainer, J L Hewett and T G Rizzo The role of an e+e- linear collider in the study of cosmic dark matter M Battaglia Collider, direct and indirect detection of supersymmetric dark matter Howard Baer, Eun-Kyung Park and Xerxes Tata INDIRECT PARTICLE DARK MATTER SEARCHES:EXPERIMENTS PAMELA and indirect dark matter searches M Boezio et al An indirect search for dark matter using antideuterons: the GAPS experiment C J Hailey Perspectives for indirect dark matter search with AMS-2 using cosmic-ray electrons and positrons B Beischer, P von

  6. Expression of the sFLT1 gene in cord blood cells is associated to maternal arsenic exposure and decreased birth weight

    DEFF Research Database (Denmark)

    Remy, Sylvie; Govarts, Eva; Bruckers, Liesbeth

    2014-01-01

    that birth weight decreased with 47 g (95% CI: 16-78 g) for an interquartile range increase of 0.99 μg/L arsenic. The model was adjusted for child's sex, maternal smoking during pregnancy, gestational age, and parity. Higher arsenic concentrations and reduced birth weight were positively associated...... with changes in expression of the sFLT1 (soluble fms-like tyrosine kinase-1) gene in cord blood cells in girls. The protein product of sFLT1 is a scavenger of vascular endothelial growth factor (VEGF) in the extracellular environment and plays a key role in the inhibition of placental angiogenesis. In terms...

  7. Application of fast spin-echo T2-weighted imaging for examination of the neurocranium. Comparison with the conventional T2-weighted spin-echo sequence

    International Nuclear Information System (INIS)

    Siewert, C.; Hosten, N.; Felix, R.

    1994-01-01

    T 2 -weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T 2 -weighted imaging (TT 2 ) of the neurocranium in comparison to conventional spin-echo T 2 -weighted imaging (T 2 ). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT 2 than in T 2 (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT 2 , Parkinson patients have to be examined by conventional T 2 . If these limitations are taken into account, fast spin-echo T 2 -weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T 2 -weighting achieved in a short acquisition time. (orig.) [de

  8. A prospective comparison study of fast T1 weighted fluid attenuation inversion recovery and T1 weighted turbo spin echo sequence at 3 T in degenerative disease of the cervical spine.

    Science.gov (United States)

    Ganesan, K; Bydder, G M

    2014-09-01

    This study compared T1 fluid attenuation inversion recovery (FLAIR) and T1 turbo spin echo (TSE) sequences for evaluation of cervical spine degenerative disease at 3 T. 72 patients (44 males and 28 females; mean age of 39 years; age range, 27-75 years) with suspected cervical spine degenerative disease were prospectively evaluated. Sagittal images of the spine were obtained using T1 FLAIR and T1 TSE sequences. Two experienced neuroradiologists compared the sequences qualitatively and quantitatively. On qualitative evaluation, cerebrospinal fluid (CSF) nulling and contrast at cord-CSF, disc-CSF and disc-cord interfaces were significantly higher on fast T1 FLAIR images than on T1 TSE images (p degenerative disease, owing to higher cord-CSF, disc-cord and disc-CSF contrast. However, intrinsic cord contrast is low on T1 FLAIR images. T1 FLAIR is more promising and sensitive than T1 TSE for evaluation of degenerative spondyloarthropathy and may provide a foundation for development of MR protocols for early detection of degenerative and neoplastic diseases.

  9. Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Wright, Nancy; Deeb, Larry C

    2017-12-23

    To determine patterns of blood glucose monitoring in children and adolescents with type 1 diabetes (T1D) before and after routine T1D clinic visits. Blood glucose monitoring data were downloaded at four consecutive routine clinic visits from children and adolescents aged 5-18 years. Linear mixed models were used to analyze patterns of blood glucose monitoring in patients who had at least 28 days of data stored in their blood glucose monitors. In general, the frequency of blood glucose monitoring decreased across visits, and younger children engaged in more frequent blood glucose monitoring. Blood glucose monitoring increased before the T1D clinic visits in younger children, but not in adolescents. It declined after the visit regardless of age. Members of the T1D care team need to consider that a T1D clinic visit may prompt an increase in blood glucose monitoring when making treatment changes and recommendations. Tailored interventions are needed to maintain that higher level of adherence across time. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  10. Dark energy in systems of galaxies

    Science.gov (United States)

    Chernin, A. D.

    2013-11-01

    The precise observational data of the Hubble Space Telescope have been used to study nearby galaxy systems. The main result is the detection of dark energy in groups, clusters, and flows of galaxies on a spatial scale of about 1-10 Mpc. The local density of dark energy in these systems, which is determined by various methods, is close to the global value or even coincides with it. A theoretical model of the nearby Universe has been constructed, which describes the Local Group of galaxies with the flow of dwarf galaxies receding from this system. The key physical parameter of the group-flow system is zero gravity radius, which is the distance at which the gravity of dark matter is compensated by dark-energy antigravity. The model predicts the existence of local regions of space where Einstein antigravity is stronger than Newton gravity. Six such regions have been revealed in the data of the Hubble space telescope. The nearest of these regions is at a distance of 1-3 Mpc from the center of the Milky Way. Antigravity in this region is several times stronger than gravity. Quasiregular flows of receding galaxies, which are accelerated by the dark-energy antigravity, exist in these regions. The model of the nearby Universe at the scale of groups of galaxies (˜1 Mpc) can be extended to the scale of clusters (˜10 Mpc). The systems of galaxies with accelerated receding flows constitute a new and probably widespread class of metagalactic populations. Strong dynamic effects of local dark energy constitute the main characteristic feature of these systems.

  11. A preliminary study of the T1rho values of normal knee cartilage using 3 T-MRI

    International Nuclear Information System (INIS)

    Goto, Hajimu; Iwama, Yuki; Fujii, Masahiko; Aoyama, Nobukazu; Kubo, Seiji; Kuroda, Ryosuke; Ohno, Yoshiharu; Sugimura, Kazuro

    2012-01-01

    Introduction: To investigate the degree of the effect of aging and weight-bearing on T1rho values in normal cartilage. Materials and methods: Thirty-two asymptomatic patients were examined using 3.0-T magnetic resonance imaging (MRI) to determine knee cartilage T1rho values and T2 values. The femoral and tibial cartilage was divided into weight-bearing (WB-Rs) and less-weight-bearing (LWB-Rs) regions. Single regression analysis was used to assess the relationship between cartilage T1rho values and age and between T2 values and age. Analysis of variance and post hoc-testing were used to evaluate differences in WB-Rs and LWB-Rs cartilage T1rho values and T2 values. Multiple linear regression modeling was performed to predict cartilage T1rho values. Results: Cartilage T1rho values correlated positively with age for all cartilage regions tested (p < 0.001). There were no significant correlations between cartilage T2 values and age. In both the medial femoral and tibial cartilage, T1rho values were significantly higher in WB-Rs than in LWB-Rs (p < 0.05). There were no significant differences in T2 values between WB-Rs and LWB-Rs. Multiple linear regression analysis showed that both age and weight-bearing were significant predictors of increased medial knee cartilage T1rho values (p < 0.001). Conclusions: Aging and the degree of weight-bearing correlate with the change in cartilage T1rho values. Based on multiple regression modeling, aging may be a more important factor than weight-bearing for cartilage T1rho values.

  12. Bone marrow response in treated patients with Gaucher disease: evaluation by T1-weighted magnetic resonance images and correlation with reduction in liver and spleen volume

    International Nuclear Information System (INIS)

    Terk, M.R.; Dardashti, S.; Liebman, H.A.

    2000-01-01

    Purpose. To determine whether T1-weighted magnetic resonance (MR) images can demonstrate response in the marrow of patients with type 1 Gaucher disease treated with enzyme replacement therapy (ERT) and to determine whether a relationship exists between liver and spleen volume reductions and visible marrow changes.Patients. Forty-two patients with type 1 Gaucher disease were evaluated on at least two occasions. Thirty-two patients received ERT. Of these patients, 15 had a baseline examination prior to the initiation of ERT. The remaining 10 patients did not receive ERT.Design. T1-weighted and gradient recalled echo (GRE) coronal images of the femurs and hips were obtained. Concurrently, liver and spleen volumes were determined using contiguous breath-hold axial gradient-echo images. T1-weighted images of the hips and femurs were evaluated to determine change or lack of change in the yellow marrow.Results. Of the 32 patients receiving ERT, 14 (44%) demonstrated increased signal on T1-weighted images suggesting an increase in the amount of yellow marrow. If only the 15 patients with a baseline examination were considered, the response rate to ERT was 67%. Using Student's t-test a highly significant correlation (P<0.005) was found between marrow response and reduction in liver and spleen volume.Conclusions. Marrow changes in patients receiving ERT can be detected by T1-weighted images. This response correlated with reductions in visceral volumes (P<0.0005). (orig.)

  13. Biopsychosocial Aspects of Weight Management in Type 1 Diabetes: a Review and Next Steps.

    Science.gov (United States)

    Driscoll, Kimberly A; Corbin, Karen D; Maahs, David M; Pratley, Richard; Bishop, Franziska K; Kahkoska, Anna; Hood, Korey K; Mayer-Davis, Elizabeth

    2017-08-01

    This review aims to summarize the type 1 diabetes (T1D) and weight literature with an emphasis on barriers associated with weight management, the unique T1D-specific factors that impact weight loss success, maladaptive and adaptive strategies for weight loss, and interventions to promote weight loss. Weight gain is associated with intensive insulin therapy. Overweight and obese weight status in individuals with T1D is higher than the general population and prevalence is rising. A variety of demographic (e.g., female sex), clinical (e.g., greater insulin needs), environmental (e.g., skipping meals), and psychosocial (e.g., depression, stress) factors are associated with overweight/obese weight status in T1D. Fear of hypoglycemia is a significant barrier to engagement in physical activity. Studies evaluating adaptive weight loss strategies in people with T1D are limited. There is a growing literature highlighting the prevalence and seriousness of overweight and obesity among both youth and adults with T1D. There is an urgent need to develop evidence-based weight management guidelines and interventions that address the unique concerns of individuals with T1D and that concurrently address glycemic control.

  14. Constraining the mSUGRA (minimal supergravity) parameter space using the entropy of dark matter halos

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, Dario; Zavala, Jesus; Nellen, Lukas; Sussman, Roberto A [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico (ICN-UNAM), AP 70-543, Mexico 04510 DF (Mexico); Cabral-Rosetti, Luis G [Departamento de Posgrado, Centro Interdisciplinario de Investigacion y Docencia en Educacion Tecnica (CIIDET), Avenida Universidad 282 Pte., Col. Centro, Apartado Postal 752, C. P. 76000, Santiago de Queretaro, Qro. (Mexico); Mondragon, Myriam, E-mail: nunez@nucleares.unam.mx, E-mail: jzavala@nucleares.unam.mx, E-mail: jzavala@shao.ac.cn, E-mail: lukas@nucleares.unam.mx, E-mail: sussman@nucleares.unam.mx, E-mail: lgcabral@ciidet.edu.mx, E-mail: myriam@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico (IF-UNAM), Apartado Postal 20-364, 01000 Mexico DF (Mexico); Collaboration: For the Instituto Avanzado de Cosmologia, IAC

    2008-05-15

    We derive an expression for the entropy of a dark matter halo described using a Navarro-Frenk-White model with a core. The comparison of this entropy with that of dark matter in the freeze-out era allows us to constrain the parameter space in mSUGRA models. Moreover, combining these constraints with the ones obtained from the usual abundance criterion and demanding that these criteria be consistent with the 2{sigma} bounds for the abundance of dark matter: 0.112{<=}{Omega}{sub DM}h{sup 2}{<=}0.122, we are able to clearly identify validity regions among the values of tan{beta}, which is one of the parameters of the mSUGRA model. We found that for the regions of the parameter space explored, small values of tan{beta} are not favored; only for tan {beta} Asymptotically-Equal-To 50 are the two criteria significantly consistent. In the region where the two criteria are consistent we also found a lower bound for the neutralino mass, m{sub {chi}}{>=}141 GeV.

  15. Constraining the mSUGRA (minimal supergravity) parameter space using the entropy of dark matter halos

    International Nuclear Information System (INIS)

    Núñez, Darío; Zavala, Jesús; Nellen, Lukas; Sussman, Roberto A; Cabral-Rosetti, Luis G; Mondragón, Myriam

    2008-01-01

    We derive an expression for the entropy of a dark matter halo described using a Navarro–Frenk–White model with a core. The comparison of this entropy with that of dark matter in the freeze-out era allows us to constrain the parameter space in mSUGRA models. Moreover, combining these constraints with the ones obtained from the usual abundance criterion and demanding that these criteria be consistent with the 2σ bounds for the abundance of dark matter: 0.112≤Ω DM h 2 ≤0.122, we are able to clearly identify validity regions among the values of tanβ, which is one of the parameters of the mSUGRA model. We found that for the regions of the parameter space explored, small values of tanβ are not favored; only for tan β ≃ 50 are the two criteria significantly consistent. In the region where the two criteria are consistent we also found a lower bound for the neutralino mass, m χ ≥141 GeV

  16. Evaluation of MRI sequences for quantitative T1 brain mapping

    Science.gov (United States)

    Tsialios, P.; Thrippleton, M.; Glatz, A.; Pernet, C.

    2017-11-01

    T1 mapping constitutes a quantitative MRI technique finding significant application in brain imaging. It allows evaluation of contrast uptake, blood perfusion, volume, providing a more specific biomarker of disease progression compared to conventional T1-weighted images. While there are many techniques for T1-mapping there is a wide range of reported T1-values in tissues, raising the issue of protocols reproducibility and standardization. The gold standard for obtaining T1-maps is based on acquiring IR-SE sequence. Widely used alternative sequences are IR-SE-EPI, VFA (DESPOT), DESPOT-HIFI and MP2RAGE that speed up scanning and fitting procedures. A custom MRI phantom was used to assess the reproducibility and accuracy of the different methods. All scans were performed using a 3T Siemens Prisma scanner. The acquired data processed using two different codes. The main difference was observed for VFA (DESPOT) which grossly overestimated T1 relaxation time by 214 ms [126 270] compared to the IR-SE sequence. MP2RAGE and DESPOT-HIFI sequences gave slightly shorter time than IR-SE (~20 to 30ms) and can be considered as alternative and time-efficient methods for acquiring accurate T1 maps of the human brain, while IR-SE-EPI gave identical result, at a cost of a lower image quality.

  17. Weighted local Hardy spaces associated with operators

    Indian Academy of Sciences (India)

    RUMING GONG

    2018-04-24

    5 days ago ... Studies 116 (1985) (Amsterdam: North Holland). [12] Gong R M and Yan L X, Littlewood–Paley and spectral multipliers on weighted L p spaces, J. Geom. Anal. 24 (2014) 873–900. [13] Gong R M, Li J and Yan L X, A local version of Hardy spaces associated with operators on metric spaces, Sci. China Math.

  18. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  19. Capabilities of diffusion-weighted and fresh blood imaging in depicting fresh thrombus. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ando, Ritsuko; Manabe, Tsutomu; Tazawa, Satoru

    2007-01-01

    We examined the capabilities of diffusion-weighted (DWI) and fresh-blood imaging (FBI) in depicting thrombus. A paper-clay phantom holding test syringes of various sizes filled with either contrast medium or fresh human blood were scanned using a 1.5T magnetic resonance (MR) imaging unit, and apparent diffusion coefficient (ADC) values and signal intensities on DWI and FBI of the specimens were obtained. FBI depicted all the specimens regardless of syringe diameter, but DWI failed to image the syringe measuring 0.5 cm in diameter. B-factors and/or number of acquisitions (NAQ) seemed responsible for DWI's depiction capability. ADC values and signal intensities on DWI and FBI correlated with the viscosity of the contrast medium samples. Clotted blood, the most viscous of the samples, had the smallest ADC value and no relationship with signal intensities on DWI and FBI. Larger b-factors reduced signal intensity in contrast medium on DWI, but signals decreased only minimally in clotted blood. The result suggested that although viscosity was the influential factor for signal intensities on DWI in contrast medium, other factors, such as particle sizes of fibrin and hemoglobin, accounted for the low ADC values in clotting blood. T 2 relaxation time seemed to play a significant role in making signal intensities on DWI irrelevant to b-factors. Despite lapsed time, the clots were persistently hyperintense on FBI with a tendency to decrease only gradually. On DWI, there was a certain period when signal intensities were high and ADC values were low. The signal intensities on DWI and ADC values were considered to be influenced by the process of clot formation, and disappearance of signal seemed likely attributable to degeneration of protein and organization of the clot. (author)

  20. Does Ramadan fasting alter body weight and blood lipids and fasting blood glucose in a healthy population? A meta-analysis.

    Science.gov (United States)

    Kul, Seval; Savaş, Esen; Öztürk, Zeynel Abidin; Karadağ, Gülendam

    2014-06-01

    In this study, we conducted a meta-analysis of self-controlled cohort studies comparing body weights, blood levels of lipids and fasting blood glucose levels before and after Ramadan taking into account gender differences. Several databases were searched up to June 2012 for studies showing an effect of Ramadan fasting in healthy subjects, yielding 30 articles. The primary finding of this meta-analysis was that after Ramadan fasting, low-density lipoprotein (SMD = -1.67, 95 % CI = -2.48 to -0.86) and fasting blood glucose levels (SMD = -1.10, 95 % CI = -1.62 to -0.58) were decreased in both sex groups and also in the entire group compared to levels prior to Ramadan. In addition, in the female subgroup, body weight (SMD = -0.04, 95 % CI = -0.20, 0.12), total cholesterol (SMD = 0.05, 95 % CI = -0.51 to 0.60), and triglyceride levels (SMD = 0.03, 95 % CI = -0.31, 0.36) remained unchanged, while HDL levels (SMD = 0.86, 95 % CI = 0.11 to 1.61, p = 0.03) were increased. In males, Ramadan fasting resulted in weight loss (SMD = -0.24, 95 % CI = -0.36, -0.12, p = 0.001). Also, a substantial reduction in total cholesterol (SMD = -0.44, 95 % CI = -0.77 to -0.11) and LDL levels (SMD = -2.22, 95 % CI = -3.47 to -0.96) and a small decrease in triglyceride levels (SMD = -0.35, 95 % CI = -0.67 to -0.02) were observed in males. In conclusion, by looking at this data, it is evident that Ramadan fasting can effectively change body weight and some biochemical parameters in healthy subjects especially in males compared to pre-Ramadan period.

  1. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1-weighted perfusion MRI

    DEFF Research Database (Denmark)

    Larsson, Henrik B.W.; Vestergaard, Mark B.; Lindberg, Ulrich

    2017-01-01

    Purpose: Capillary transit time heterogeneity, measured as CTH, may set the upper limit for extraction of substances in brain tissue, e.g., oxygen. The purpose of this study was to investigate the feasibility of dynamic contrast-enhanced T1 weighted MRI (DCE-MRI) at 3 Tesla (T), in estimating CTH...

  2. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    Science.gov (United States)

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  3. BUV/Nimbus-4 Dark Current Study Working Data V001 (BUVN4L1DCW) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Nimbus-4 BUV Level-1 Dark Current Study Working Data is derived from the BUV Level 1 Radiance (RUT) product and contains the geophysical indices and...

  4. Dark current spectroscopy of space and nuclear environment induced displacement damage defects in pinned photodiode based CMOS image sensors

    International Nuclear Information System (INIS)

    Belloir, Jean-Marc

    2016-01-01

    CMOS image sensors are envisioned for an increasing number of high-end scientific imaging applications such as space imaging or nuclear experiments. Indeed, the performance of high-end CMOS image sensors has dramatically increased in the past years thanks to the unceasing improvements of microelectronics, and these image sensors have substantial advantages over CCDs which make them great candidates to replace CCDs in future space missions. However, in space and nuclear environments, CMOS image sensors must face harsh radiation which can rapidly degrade their electro-optical performances. In particular, the protons, electrons and ions travelling in space or the fusion neutrons from nuclear experiments can displace silicon atoms in the pixels and break the crystalline structure. These displacement damage effects lead to the formation of stable defects and to the introduction of states in the forbidden bandgap of silicon, which can allow the thermal generation of electron-hole pairs. Consequently, non ionizing radiation leads to a permanent increase of the dark current of the pixels and thus a decrease of the image sensor sensitivity and dynamic range. The aim of the present work is to extend the understanding of the effect of displacement damage on the dark current increase of CMOS image sensors. In particular, this work focuses on the shape of the dark current distribution depending on the particle type, energy and fluence but also on the image sensor physical parameters. Thanks to the many conditions tested, an empirical model for the prediction of the dark current distribution induced by displacement damage in nuclear or space environments is experimentally validated and physically justified. Another central part of this work consists in using the dark current spectroscopy technique for the first time on irradiated CMOS image sensors to detect and characterize radiation-induced silicon bulk defects. Many types of defects are detected and two of them are identified

  5. Academic Training Lecture Regular Programme: Particle Physics Foundations of Dark Matter, Dark Energy, and Inflation (1/3)

    CERN Multimedia

    2012-01-01

    Particle Physics Foundations of Dark Matter, Dark Energy, and Inflation (1/3), by Dr. Edward (Rocky) Kolb (University of Chicago).   Wednesday, May 9, 2012 from 11:00 to 12:00 (Europe/Zurich) at CERN ( 500-1-001 - Main Auditorium ) Ninety-five percent of the present mass-energy density of the Universe is dark.  Twenty-five percent is in the form of dark matter holding together galaxies and other large scale structures, and 70% is in the form of dark energy driving an accelerated expansion of the universe.  Dark matter and dark energy cannot be explained within the standard model of particle physics.  In the first lecture I will review the evidence for dark matter and the observations that point to an explanation in the form of cold dark matter.  I will then describe the expected properties of a hypothetical Weakly-Interacting Massive Particle, or WIMP, and review experimental and observational approaches to test the hypothesis.  Finally, I will discus...

  6. Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia?

    International Nuclear Information System (INIS)

    Baudelet, Christine; Ansiaux, Reginald; Jordan, Benedicte F; Havaux, Xavier; Macq, Benoit; Gallez, Bernard

    2004-01-01

    T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions

  7. Dark forces in the sky: signals from Z{sup ′} and the dark Higgs

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Nicole F.; Cai, Yi; Leane, Rebecca K. [ARC Centre of Excellence for Particle Physics at the Terascale, School of Physics,The University of Melbourne,Victoria 3010 (Australia)

    2016-08-01

    We consider the indirect detection signals for a self-consistent hidden U(1) model containing a Majorana dark matter candidate, χ, a dark gauge boson, Z{sup ′}, and a dark Higgs, s. Compared with a model containing only a dark matter candidate and Z{sup ′} mediator, the addition of the scalar provides a mass generation mechanism for the dark sector particles and is required in order to avoid unitarity violation at high energies. We find that the inclusion of the two mediators opens up a new two-body s-wave annihilation channel, χχ→sZ{sup ′}. This new process, which is missed in the usual single-mediator simplified model approach, can be the dominant annihilation channel. This provides rich phenomenology for indirect detection searches, allows indirect searches to explore regions of parameter space not accessible with other commonly considered s-wave annihilation processes, and enables both the Z{sup ′} and scalar couplings to be probed. We examine the phenomenology of the sector with a focus on this new process, and determine the limits on the model parameter space from Fermi data on dwarf spheriodal galaxies and other relevant experiments.

  8. Heavily T2-weighted MR myelography vs CT myelography in spontaneous intracranial hypotension.

    Science.gov (United States)

    Wang, Y-F; Lirng, J-F; Fuh, J-L; Hseu, S-S; Wang, S-J

    2009-12-01

    To assess the diagnostic accuracy of heavily T2-weighted magnetic resonance myelography (MRM) in patients with spontaneous intracranial hypotension (SIH). Patients with SIH were recruited prospectively, and first underwent MRM and then computed tomographic myelography (CTM). The results of MRM were validated with the gold standard, CTM, focusing on 1) CSF leaks along the nerve roots, 2) epidural CSF collections, and 3) high-cervical (C1-3) retrospinal CSF collections. Comparisons of these 3 findings between the 2 studies were made by kappa statistics and agreement rates. Targeted epidural blood patches (EBPs) were placed at the levels of CSF leaks if supportive treatment failed. Nineteen patients (6 men and 13 women, mean age 37.9 +/- 8.6 years) with SIH completed the study. MRM did not differ from CTM in the detection rates of CSF leaks along the nerve roots (84% vs 74%, p = 0.23), high-cervical retrospinal CSF collections (32% vs 16%, p = 0.13), and epidural CSF collections (89% vs 79%, p = 0.20). MRM demonstrated more spinal levels of CSF leaks (2.2 +/- 1.7 vs 1.5 +/- 1.5, p = 0.011) and epidural collections (12.2 +/- 5.9 vs 7.1 +/- 5.8, p localizing CSF leaks for patients with spontaneous intracranial hypotension. This noninvasive technique may be an alternative to computed tomographic myelography before targeted epidural blood patches.

  9. Effect of prenatal exposure to different salt concentration on the third month's weight and blood pressure in wistar rat

    International Nuclear Information System (INIS)

    Fereidoun, H.

    2009-01-01

    In utero alterations in fluid and electrolyte endocrine systems may result in permanent effects on offspring. A low sodium intake during prenatal life jeopardizes growth in young rats, prenatal high-salt diet in Sprague-Dawley rats caused an increase in MAP at postnatal day 30. The objective of this study was to determine the effect of prenatal exposure to different salt concentrations on the third month's weight and blood pressure in Wistar rat. This study was performed at the Department of Physiology, Isfahan University of Medical Science, Isfahan, Iran, over a period from 1998 to 2003. Six groups of rat, 1 male and 5 female in each group were exposed to 0.5, 1, 1.4, 1.6, 1.8 and 2 percent of salt concentrations during pre-pregnancy, pregnancy and lactation period, another test group consumed distilled water and control group used Isfahan tap water, other living conditions for all groups were similar. Exposure to different salt concentrations on the third month's weight and blood pressure was evaluated. Prenatal exposure to 0.5 and 1% salt concentrations gives birth to more alive and healthy infants, and third month's weight increased significantly, but blood pressure was not influenced significantly. Salt concentrations higher than 1% increased the maternal and infant mortality rate and blood pressure significantly, but some concentrations decreased third month's weight significantly. Level of dietary salt during intrauterine development can influence on the number of alive and healthy infants, birth weight, third month' weight and blood pressure significantly. There is no need to introduce a salt restricted diet in prenatal care, a balanced diet in sodium during pregnancy is recommended, high salt diet creates harmful effect. (author)

  10. DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

    Science.gov (United States)

    Aalseth, C. E.; Acerbi, F.; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Antonioli, P.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Asner, D. M.; Ave, M.; Back, H. O.; Barrado Olmedo, A. I.; Batignani, G.; Bertoldo, E.; Bettarini, S.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Boulay, M.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Castellani, A.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Colocci, M.; Corgiolu, S.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Da Rocha Rolo, M. D.; Daniel, M.; Davini, S.; de Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Della Valle, M.; Demontis, P.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Dolgov, A.; Dormia, I.; Dussoni, S.; Empl, A.; Fernandez Diaz, M.; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garcia Abia, P.; Gendotti, A.; Ghisi, A.; Giagu, S.; Giampa, P.; Gibertoni, G.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, An.; Jillings, C.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kim, S.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; Kuźniak, M.; La Commara, M.; Lehnert, B.; Li, X.; Lissia, M.; Lodi, G. U.; Loer, B.; Longo, G.; Loverre, P.; Lussana, R.; Luzzi, L.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Martoff, C. J.; Mascia, M.; Mayer, M.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Monte, A.; Morrocchi, M.; Mount, B. J.; Mu, W.; Muratova, V. N.; Murphy, S.; Musico, P.; Nania, R.; Navrer Agasson, A.; Nikulin, I.; Nosov, V.; Nozdrina, A. O.; Nurakhov, N. N.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pelczar, K.; Pellegrini, L. A.; Pelliccia, N.; Perotti, F.; Perruzza, R.; Pesudo, V.; Piemonte, C.; Pilo, F.; Pocar, A.; Pollmann, T.; Portaluppi, D.; Pugachev, D. A.; Qian, H.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Retière, F.; Riffard, Q.; Rivetti, A.; Rizzardini, S.; Romani, A.; Romero, L.; Rossi, B.; Rossi, N.; Rubbia, A.; Sablone, D.; Salatino, P.; Samoylov, O.; Sánchez García, E.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Shekhtman, L.; Shemyakina, E.; Sheshukov, A.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Speziale, F.; Stainforth, R.; Stanford, C.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Tosi, A.; Trinchese, P.; Unzhakov, E. V.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Villa, F.; Vishneva, A.; Vogelaar, B.; Wada, M.; Wahl, J.; Walding, J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Williams, R.; Wojcik, M. M.; Wu, S.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Yllera de Llano, A.; Zappa, F.; Zappalà, G.; Zhu, C.; Zichichi, A.; Zullo, M.; Zullo, A.; Zuzel, G.

    2018-03-01

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of >3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ν-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2 × 10^{-47} cm2 (1.1 × 10^{-46} cm2) for WIMPs of 1 TeV/c 2 (10 TeV/c 2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

  11. Prevalence of Human T-lymphotropic virus type 1 and 2 among blood donors in Manaus, Amazonas State, Brazil

    Directory of Open Access Journals (Sweden)

    Márcia Poinho EncarnaçÃo de Morais

    2017-12-01

    Full Text Available ABSTRACT Introduction: Human T-lymphotropic virus type 1 and 2 (HTLV-1/2 is endemic in Brazil, but few studies have investigated the seroprevalence of HTLV and its subtypes among blood donors in the capital city Manaus, Amazonas State, Brazil. Aim: To estimate the seroprevalence of HTLV-1/2 and to identify circulating subtypes among blood donors in Manaus. Materials and Methods: Blood donors (2001-2003 were screened for HTLV-1/2 antibodies by ELISA. Positive results were confirmed and subtyped by Western blot assays. Prevalence rates were calculated and compared with demographic data. Results: Among the 87,402 individuals screened, 116 (0.13% were seropositive for HTLV-1/2. A second sample (76/116 was collected and retested by HTLV-1/2 ELISA, of which only 41/76 were positive. Western blot confirmed HTLV infection in 24/41 retested blood donors [HTLV-1 (n=16, HTLV-2 (n=5 and HTLV-untypable (n=3]. Discussion: HTLV-1 and HTLV-2 are prevalent among blood donors in Manaus. However, additional studies are needed to comprehend the epidemiology of HTLV-1/2 in Amazonas not only to understand the pathophysiology of the disease providing adequate medical assistance, but also to reduce or block virus transmission.

  12. Blood glucose kinetics and physiological changes in a type 1 diabetic finisher of the Ultraman triathlon: a case study.

    Science.gov (United States)

    Bach, Christopher W; Baur, Daniel A; Hyder, William S; Ormsbee, Michael J

    2017-05-01

    To investigate the blood glucose kinetics and physiological effects experienced by a type 1 diabetic (T1D) finisher of a 3-day, multi-stage ultra endurance triathlon consisting of a 10 km swim and 144.8 km bike (stage 1), a 275.4 km bike (stage 2), and an 84.4 km run (stage 3). The athlete self-monitored blood glucose (SMBG) levels via fingerstick blood draw and hand-held glucometer. Researchers evaluated blood glucose kinetics via a continuous glucose monitoring device. The athlete maintained normal dietary and insulin patterns before, during and after competition daily. Weight and body composition were measured via bioelectrical impedance and select biomarkers were measured in blood. The athlete spent 73.0, 3.4, and 15.1% of during race time in a hyperglycemic state (≥130 mg dL -1 ) during stages 1, 2, and 3, respectively, and 0.0, 78.6, and 33.6% in a hypoglycemic state (≤80 mg dL -1 ). Nocturnal glycemic levels showed the athlete spent 86.1, 83.0, and 84.8% of sleep in a hyperglycemic state during nights 1, 2, and 3, respectively, and 9.0, 0.0, and 0.0% in a hypoglycemic state. From pre- to post-race, body weight (73.2 to 76.9 kg) and total body water increased (49.2-51.6 kg). In addition, there were dramatic increases in creatine kinase (271.7-9252.8 µ L -1 ), cortisol (137.1-270.2 pg mL -1 ), CRP (188.3-8046.9 ng mL -1 ), and aldosterone (449.1-1679.6 pg mL -1 ). It is possible for a T1D athlete to complete a multi-stage ultraendurance triathlon and maintain glycemic control using SMBG methods. In addition, a T1D athlete participating in an ultraendurance triathlon results in substantial changes in body composition, hormones, and muscle damage.

  13. The phase-space structure of nearby dark matter as constrained by the SDSS

    International Nuclear Information System (INIS)

    Leclercq, Florent; Percival, Will; Jasche, Jens; Lavaux, Guilhem; Wandelt, Benjamin

    2017-01-01

    Previous studies using numerical simulations have demonstrated that the shape of the cosmic web can be described by studying the Lagrangian displacement field. We extend these analyses, showing that it is now possible to perform a Lagrangian description of cosmic structure in the nearby Universe based on large-scale structure observations. Building upon recent Bayesian large-scale inference of initial conditions, we present a cosmographic analysis of the dark matter distribution and its evolution, referred to as the dark matter phase-space sheet, in the nearby universe as probed by the Sloan Digital Sky Survey main galaxy sample. We consider its stretchings and foldings using a tetrahedral tessellation of the Lagrangian lattice. The method provides extremely accurate estimates of nearby density and velocity fields, even in regions of low galaxy density. It also measures the number of matter streams, and the deformation and parity reversals of fluid elements, which were previously thought inaccessible using observations. We illustrate the approach by showing the phase-space structure of known objects of the nearby Universe such as the Sloan Great Wall, the Coma cluster and the Boötes void. We dissect cosmic structures into four distinct components (voids, sheets, filaments, and clusters), using the Lagrangian classifiers DIVA, ORIGAMI, and a new scheme which we introduce and call LICH. Because these classifiers use information other than the sheer local density, identified structures explicitly carry physical information about their formation history. Accessing the phase-space structure of dark matter in galaxy surveys opens the way for new confrontations of observational data and theoretical models. We have made our data products publicly available.

  14. The phase-space structure of nearby dark matter as constrained by the SDSS

    Energy Technology Data Exchange (ETDEWEB)

    Leclercq, Florent; Percival, Will [Institute of Cosmology and Gravitation (ICG), University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth PO1 3FX (United Kingdom); Jasche, Jens [Excellence Cluster Universe, Technische Universität München, Boltzmannstrasse 2, D-85748 Garching (Germany); Lavaux, Guilhem; Wandelt, Benjamin, E-mail: florent.leclercq@polytechnique.org, E-mail: lavaux@iap.fr, E-mail: jasche@iap.fr, E-mail: wandelt@iap.fr, E-mail: will.percival@port.ac.uk [Institut d' Astrophysique de Paris (IAP), UMR 7095, CNRS – UPMC Université Paris 6, Sorbonne Universités, 98bis boulevard Arago, F-75014 Paris (France)

    2017-06-01

    Previous studies using numerical simulations have demonstrated that the shape of the cosmic web can be described by studying the Lagrangian displacement field. We extend these analyses, showing that it is now possible to perform a Lagrangian description of cosmic structure in the nearby Universe based on large-scale structure observations. Building upon recent Bayesian large-scale inference of initial conditions, we present a cosmographic analysis of the dark matter distribution and its evolution, referred to as the dark matter phase-space sheet, in the nearby universe as probed by the Sloan Digital Sky Survey main galaxy sample. We consider its stretchings and foldings using a tetrahedral tessellation of the Lagrangian lattice. The method provides extremely accurate estimates of nearby density and velocity fields, even in regions of low galaxy density. It also measures the number of matter streams, and the deformation and parity reversals of fluid elements, which were previously thought inaccessible using observations. We illustrate the approach by showing the phase-space structure of known objects of the nearby Universe such as the Sloan Great Wall, the Coma cluster and the Boötes void. We dissect cosmic structures into four distinct components (voids, sheets, filaments, and clusters), using the Lagrangian classifiers DIVA, ORIGAMI, and a new scheme which we introduce and call LICH. Because these classifiers use information other than the sheer local density, identified structures explicitly carry physical information about their formation history. Accessing the phase-space structure of dark matter in galaxy surveys opens the way for new confrontations of observational data and theoretical models. We have made our data products publicly available.

  15. Simplified dark matter models with a spin-2 mediator at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kraml, Sabine [Universite Grenoble-Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, Grenoble (France); Laa, Ursula [Universite Grenoble-Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, Grenoble (France); LAPTh, Universite Savoie Mont Blanc, CNRS, B.P.110, Annecy Cedex (France); Mawatari, Kentarou [Universite Grenoble-Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, Grenoble (France); Theoretische Natuurkunde and IIHE/ELEM, Vrije Universiteit Brussel, and International Solvay Institutes, Brussels (Belgium); Yamashita, Kimiko [Ochanomizu University, Department of Physics, Graduate School of Humanities and Sciences, and Program for Leading Graduate Schools, Tokyo (Japan)

    2017-05-15

    We consider simplified dark matter models where a dark matter candidate couples to the standard model (SM) particles via an s-channel spin-2 mediator, and study constraints on the model parameter space from the current LHC data. Our focus lies on the complementarity among different searches, in particular monojet and multijet plus missing-energy searches and resonance searches. For universal couplings of the mediator to SM particles, missing-energy searches can give stronger constraints than WW, ZZ, dijet, dihiggs, t anti t, b anti b resonance searches in the low-mass region and/or when the coupling of the mediator to dark matter is much larger than its couplings to SM particles. The strongest constraints, however, come from diphoton and dilepton resonance searches. Only if these modes are suppressed, missing-energy searches can be competitive in constraining dark matter models with a spin-2 mediator. (orig.)

  16. Simplified dark matter models with a spin-2 mediator at the LHC

    International Nuclear Information System (INIS)

    Kraml, Sabine; Laa, Ursula; Mawatari, Kentarou; Yamashita, Kimiko

    2017-01-01

    We consider simplified dark matter models where a dark matter candidate couples to the standard model (SM) particles via an s-channel spin-2 mediator, and study constraints on the model parameter space from the current LHC data. Our focus lies on the complementarity among different searches, in particular monojet and multijet plus missing-energy searches and resonance searches. For universal couplings of the mediator to SM particles, missing-energy searches can give stronger constraints than WW, ZZ, dijet, dihiggs, t anti t, b anti b resonance searches in the low-mass region and/or when the coupling of the mediator to dark matter is much larger than its couplings to SM particles. The strongest constraints, however, come from diphoton and dilepton resonance searches. Only if these modes are suppressed, missing-energy searches can be competitive in constraining dark matter models with a spin-2 mediator. (orig.)

  17. Dark photons from the center of the Earth: Smoking-gun signals of dark matter

    Science.gov (United States)

    Feng, Jonathan L.; Smolinsky, Jordan; Tanedo, Philip

    2016-01-01

    Dark matter may be charged under dark electromagnetism with a dark photon that kinetically mixes with the Standard Model photon. In this framework, dark matter will collect at the center of the Earth and annihilate into dark photons, which may reach the surface of the Earth and decay into observable particles. We determine the resulting signal rates, including Sommerfeld enhancements, which play an important role in bringing the Earth's dark matter population to their maximal, equilibrium value. For dark matter masses mX˜100 GeV - 10 TeV , dark photon masses mA'˜MeV -GeV , and kinetic mixing parameters ɛ ˜1 0-9- 1 0-7 , the resulting electrons, muons, photons, and hadrons that point back to the center of the Earth are a smoking-gun signal of dark matter that may be detected by a variety of experiments, including neutrino telescopes, such as IceCube, and space-based cosmic ray detectors, such as Fermi-LAT and AMS. We determine the signal rates and characteristics and show that large and striking signals—such as parallel muon tracks—are possible in regions of the (mA',ɛ ) plane that are not probed by direct detection, accelerator experiments, or astrophysical observations.

  18. Dark group: dark energy and dark matter

    International Nuclear Information System (INIS)

    Macorra, A. de la

    2004-01-01

    We study the possibility that a dark group, a gauge group with particles interacting with the standard model particles only via gravity, is responsible for containing the dark energy and dark matter required by present day observations. We show that it is indeed possible and we determine the constrains for the dark group. The non-perturbative effects generated by a strong gauge coupling constant can de determined and a inverse power law scalar potential IPL for the dark meson fields is generated parameterizing the dark energy. On the other hand it is the massive particles, e.g., dark baryons, of the dark gauge group that give the corresponding dark matter. The mass of the dark particles is of the order of the condensation scale Λ c and the temperature is smaller then the photon's temperature. The dark matter is of the warm matter type. The only parameters of the model are the number of particles of the dark group. The allowed values of the different parameters are severely restricted. The dark group energy density at Λ c must be Ω DGc ≤0.17 and the evolution and acceptable values of dark matter and dark energy leads to a constrain of Λ c and the IPL parameter n giving Λ c =O(1-10 3 ) eV and 0.28≤n≤1.04

  19. Levitating dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Kaloper, Nemanja [Department of Physics, University of California, Davis, CA 95616 (United States); Padilla, Antonio, E-mail: kaloper@physics.ucdavis.edu, E-mail: antonio.padilla@nottingham.ac.uk [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2009-10-01

    A sizable fraction of the total energy density of the universe may be in heavy particles with a net dark U(1)' charge comparable to its mass. When the charges have the same sign the cancellation between their gravitational and gauge forces may lead to a mismatch between different measures of masses in the universe. Measuring galactic masses by orbits of normal matter, such as galaxy rotation curves or lensing, will give the total mass, while the flows of dark matter agglomerates may yield smaller values if the gauge repulsion is not accounted for. If distant galaxies which house light beacons like SNe Ia contain such dark particles, the observations of their cosmic recession may mistake the weaker forces for an extra 'antigravity', and infer an effective dark energy equation of state smaller than the real one. In some cases, including that of a cosmological constant, these effects can mimic w < −1. They can also lead to a local variation of galaxy-galaxy forces, yielding a larger 'Hubble Flow' in those regions of space that could be taken for a dynamical dark energy, or superhorizon effects.

  20. Levitating dark matter

    Science.gov (United States)

    Kaloper, Nemanja; Padilla, Antonio

    2009-10-01

    A sizable fraction of the total energy density of the universe may be in heavy particles with a net dark U(1)' charge comparable to its mass. When the charges have the same sign the cancellation between their gravitational and gauge forces may lead to a mismatch between different measures of masses in the universe. Measuring galactic masses by orbits of normal matter, such as galaxy rotation curves or lensing, will give the total mass, while the flows of dark matter agglomerates may yield smaller values if the gauge repulsion is not accounted for. If distant galaxies which house light beacons like SNe Ia contain such dark particles, the observations of their cosmic recession may mistake the weaker forces for an extra `antigravity', and infer an effective dark energy equation of state smaller than the real one. In some cases, including that of a cosmological constant, these effects can mimic w < -1. They can also lead to a local variation of galaxy-galaxy forces, yielding a larger `Hubble Flow' in those regions of space that could be taken for a dynamical dark energy, or superhorizon effects.

  1. Codecaying Dark Matter.

    Science.gov (United States)

    Dror, Jeff Asaf; Kuflik, Eric; Ng, Wee Hao

    2016-11-18

    We propose a new mechanism for thermal dark matter freeze-out, called codecaying dark matter. Multicomponent dark sectors with degenerate particles and out-of-equilibrium decays can codecay to obtain the observed relic density. The dark matter density is exponentially depleted through the decay of nearly degenerate particles rather than from Boltzmann suppression. The relic abundance is set by the dark matter annihilation cross section, which is predicted to be boosted, and the decay rate of the dark sector particles. The mechanism is viable in a broad range of dark matter parameter space, with a robust prediction of an enhanced indirect detection signal. Finally, we present a simple model that realizes codecaying dark matter.

  2. Dark-matter QCD-axion searches

    International Nuclear Information System (INIS)

    Rosenberg, Leslie J

    2010-01-01

    The axion is a hypothetical elementary particle appearing in a simple and elegant extension to the Standard Model of particle physics that cancels otherwise huge CP-violating effects in QCD; this extension has a broken U(1) axial symmetry, where the resulting Goldstone Boson is the axion. A light axion of mass 10 -(6-3) eV (the so-called i nvisible axion ) would couple extraordinarily weakly to normal matter and radiation and would therefore be extremely difficult to detect in the laboratory. However, such an axion would be a compelling dark-matter candidate and is therefore a target of a number of searches. Compared to other dark-matter candidates, the plausible range of axion dark-matter couplings and masses is narrowly constrained. This restricted search space allows for 'definitive' searches, where non-observation would seriously impugn the dark-matter QCD-axion hypothesis. Axion searches employ a wide range of technologies and techniques, from astrophysical observations to laboratory electromagnetic signal detection. For some experiments, sensitivities are have reached likely dark-matter axion couplings and masses. This is a brief and selective overview of axion searches. With only very limited space, I briefly describe just two of the many experiments that are searching for dark-matter axions.

  3. Sub-Millimeter T2 Weighted fMRI at 7 T: Comparison of 3D-GRASE and 2D SE-EPI

    Directory of Open Access Journals (Sweden)

    Valentin G. Kemper

    2015-05-01

    Full Text Available Functional magnetic resonance imaging (fMRI allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD contrast employing T2* weighted 2D multi-slice echo-planar imaging (EPI. At ultra-high magnetic field (i.e. 7 T and above, it has been shown experimentally and by simulation, that T2 weighted acquisitions yield a signal that is spatially more specific to the site of neuronal activity at the cost of functional sensitivity. This study compared two T2 weighted imaging sequences, inner-volume 3D Gradient-and-Spin-Echo (3D-GRASE and 2D Spin-Echo EPI (SE-EPI, with evaluation of their imaging point-spread function, functional specificity, and functional sensitivity at sub-millimeter resolution. Simulations and measurements of the imaging point-spread function revealed that the strongest anisotropic blurring in 3D-GRASE (along the second phase-encoding direction was about 60 % higher than the strongest anisotropic blurring in 2D SE-EPI (along the phase-encoding direction In a visual paradigm, the BOLD sensitivity of 3D-GRASE was found to be superior due to its higher temporal signal-to-noise ratio. High resolution cortical depth profiles suggested that the contrast mechanisms are similar between the two sequences, however, 2D SE-EPI had a higher surface bias owing to the higher T2* contribution of the longer in-plane EPI echo-train for full field of view compared to the reduced field of view of zoomed 3D-GRASE.

  4. Designing future dark energy space missions. II. Photometric redshift of space weak lensing optimized surveys

    Science.gov (United States)

    Jouvel, S.; Kneib, J.-P.; Bernstein, G.; Ilbert, O.; Jelinsky, P.; Milliard, B.; Ealet, A.; Schimd, C.; Dahlen, T.; Arnouts, S.

    2011-08-01

    Context. With the discovery of the accelerated expansion of the universe, different observational probes have been proposed to investigate the presence of dark energy, including possible modifications to the gravitation laws by accurately measuring the expansion of the Universe and the growth of structures. We need to optimize the return from future dark energy surveys to obtain the best results from these probes. Aims: A high precision weak-lensing analysis requires not an only accurate measurement of galaxy shapes but also a precise and unbiased measurement of galaxy redshifts. The survey strategy has to be defined following both the photometric redshift and shape measurement accuracy. Methods: We define the key properties of the weak-lensing instrument and compute the effective PSF and the overall throughput and sensitivities. We then investigate the impact of the pixel scale on the sampling of the effective PSF, and place upper limits on the pixel scale. We then define the survey strategy computing the survey area including in particular both the Galactic absorption and Zodiacal light variation accross the sky. Using the Le Phare photometric redshift code and realistic galaxy mock catalog, we investigate the properties of different filter-sets and the importance of the u-band photometry quality to optimize the photometric redshift and the dark energy figure of merit (FoM). Results: Using the predicted photometric redshift quality, simple shape measurement requirements, and a proper sky model, we explore what could be an optimal weak-lensing dark energy mission based on FoM calculation. We find that we can derive the most accurate the photometric redshifts for the bulk of the faint galaxy population when filters have a resolution ℛ ~ 3.2. We show that an optimal mission would survey the sky through eight filters using two cameras (visible and near infrared). Assuming a five-year mission duration, a mirror size of 1.5 m and a 0.5 deg2 FOV with a visible pixel

  5. Profiling MHC II immunopeptidome of blood-stage malaria reveals that cDC1 control the functionality of parasite-specific CD4 T cells.

    Science.gov (United States)

    Draheim, Marion; Wlodarczyk, Myriam F; Crozat, Karine; Saliou, Jean-Michel; Alayi, Tchilabalo Dilezitoko; Tomavo, Stanislas; Hassan, Ali; Salvioni, Anna; Demarta-Gatsi, Claudia; Sidney, John; Sette, Alessandro; Dalod, Marc; Berry, Antoine; Silvie, Olivier; Blanchard, Nicolas

    2017-11-01

    In malaria, CD4 Th1 and T follicular helper (T FH ) cells are important for controlling parasite growth, but Th1 cells also contribute to immunopathology. Moreover, various regulatory CD4 T-cell subsets are critical to hamper pathology. Yet the antigen-presenting cells controlling Th functionality, as well as the antigens recognized by CD4 T cells, are largely unknown. Here, we characterize the MHC II immunopeptidome presented by DC during blood-stage malaria in mice. We establish the immunodominance hierarchy of 14 MHC II ligands derived from conserved parasite proteins. Immunodominance is shaped differently whether blood stage is preceded or not by liver stage, but the same ETRAMP-specific dominant response develops in both contexts. In naïve mice and at the onset of cerebral malaria, CD8α + dendritic cells (cDC1) are superior to other DC subsets for MHC II presentation of the ETRAMP epitope. Using in vivo depletion of cDC1, we show that cDC1 promote parasite-specific Th1 cells and inhibit the development of IL-10 + CD4 T cells. This work profiles the P. berghei blood-stage MHC II immunopeptidome, highlights the potency of cDC1 to present malaria antigens on MHC II, and reveals a major role for cDC1 in regulating malaria-specific CD4 T-cell responses. © 2017 The Authors. Published under the terms of the CC BY 4.0 license.

  6. The dark side of cosmology: dark matter and dark energy.

    Science.gov (United States)

    Spergel, David N

    2015-03-06

    A simple model with only six parameters (the age of the universe, the density of atoms, the density of matter, the amplitude of the initial fluctuations, the scale dependence of this amplitude, and the epoch of first star formation) fits all of our cosmological data . Although simple, this standard model is strange. The model implies that most of the matter in our Galaxy is in the form of "dark matter," a new type of particle not yet detected in the laboratory, and most of the energy in the universe is in the form of "dark energy," energy associated with empty space. Both dark matter and dark energy require extensions to our current understanding of particle physics or point toward a breakdown of general relativity on cosmological scales. Copyright © 2015, American Association for the Advancement of Science.

  7. High-intensity facial nerve lesions on T2-weighted images in chronic persistent facial nerve palsy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Dept. of Radiology, Tottori Univ. (Japan); Ishii, K. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Okitsu, T. [Dept. of Otolaryngology, Sendai City Hospital (Japan); Ogawa, T. [Dept. of Radiology, Tottori Univ. (Japan); Okudera, T. [Dept. of Radiology, Research Inst. of Brain and Blood Vessels-Akita, Akita (Japan)

    2001-05-01

    Our aim was to estimate the value of MRI in detecting irreversibly paralysed facial nerves. We examined 95 consecutive patients with a facial nerve palsy (14 with a persistent palsy, and 81 with good recovery), using a 1.0 T unit, with T2-weighted and contrast-enhanced T1-weighted images. The geniculate ganglion and tympanic segment had gave high signal on T2-weighted images in the chronic stage of persistent palsy, but not in acute palsy. The enhancement pattern of the facial nerve in the chronic persistent facial nerve palsy is similar to that in the acute palsy with good recovery. These findings suggest that T2-weighted MRI can be used to show severely damaged facial nerves. (orig.)

  8. Supergravity, Dark Energy and the Fate of the Universe

    Energy Technology Data Exchange (ETDEWEB)

    Shmakova, Marina

    2002-09-27

    We propose a description of dark energy and acceleration of the universe in extended supergravities with de Sitter (dS) solutions. Some of them are related to M-theory with non-compact internal spaces. Masses of ultra-light scalars in these models are quantized in units of the Hubble constant: m{sup 2} = nH{sup 2}. If dS solution corresponds to a minimum of the effective potential, the universe eventually becomes dS space. If dS solution corresponds to a maximum or a saddle point, which is the case in all known models based on N = 8 supergravity, the flat universe eventually stops accelerating and collapses to a singularity. We show that in these models, as well as in the simplest models of dark energy based on N = 1 supergravity, the typical time remaining before the global collapse is comparable to the present age of the universe, t = O(10{sup 10}) years. We discuss the possibility of distinguishing between various models and finding our destiny using cosmological observations.

  9. Comparison of axial T1 spin-echo and T1 fat-saturation magnetic resonance imaging techniques in the diagnosis of chondromalacia patellae.

    Science.gov (United States)

    Vanarthos, W J; Pope, T L; Monu, J U

    1994-12-01

    To test the diagnostic value of T1 spin-echo and T1 fat-saturated magnetic resonance images (MRIs), we reviewed axial T1-weighted images with and without fat saturation in 20 patients with clinically suspected chondromalacia of the patella. All scans were obtained on 1.5-MR units. The scans were randomly ordered and reviewed independently at different times by two radiologists without knowledge of the arthroscopy results. The sensitivity of the individual techniques for detecting grade 3 or 4 chondromalacia patellae was 92% for fat-saturated axial T1-weighted images alone, and 67% for axial T1-weighted images without fat saturation. The sensitivity of the combined techniques was 100% for grades 3 and 4 and 90% for all grades (0 to 4). Chondromalacia patellae is diagnosed more accurately by using T1 fat saturation than by using T1 spin-echo images. With a combination of the two techniques, accuracy is 90% to 100%.

  10. Modelling non-linear effects of dark energy

    Science.gov (United States)

    Bose, Benjamin; Baldi, Marco; Pourtsidou, Alkistis

    2018-04-01

    We investigate the capabilities of perturbation theory in capturing non-linear effects of dark energy. We test constant and evolving w models, as well as models involving momentum exchange between dark energy and dark matter. Specifically, we compare perturbative predictions at 1-loop level against N-body results for four non-standard equations of state as well as varying degrees of momentum exchange between dark energy and dark matter. The interaction is modelled phenomenologically using a time dependent drag term in the Euler equation. We make comparisons at the level of the matter power spectrum and the redshift space monopole and quadrupole. The multipoles are modelled using the Taruya, Nishimichi and Saito (TNS) redshift space spectrum. We find perturbation theory does very well in capturing non-linear effects coming from dark sector interaction. We isolate and quantify the 1-loop contribution coming from the interaction and from the non-standard equation of state. We find the interaction parameter ξ amplifies scale dependent signatures in the range of scales considered. Non-standard equations of state also give scale dependent signatures within this same regime. In redshift space the match with N-body is improved at smaller scales by the addition of the TNS free parameter σv. To quantify the importance of modelling the interaction, we create mock data sets for varying values of ξ using perturbation theory. This data is given errors typical of Stage IV surveys. We then perform a likelihood analysis using the first two multipoles on these sets and a ξ=0 modelling, ignoring the interaction. We find the fiducial growth parameter f is generally recovered even for very large values of ξ both at z=0.5 and z=1. The ξ=0 modelling is most biased in its estimation of f for the phantom w=‑1.1 case.

  11. Heavy weight vehicle traffic and its relationship with antimony content in human blood.

    Science.gov (United States)

    Quiroz, Waldo; De Gregori, Ida; Basilio, Paola; Bravo, Manuel; Pinto, Marcela; Lobos, Maria Gabriela

    2009-05-01

    Brake pads systems are nowadays considered as one of the most important sources of antimony in airborne particulate matter. One way that antimony can enter the body is through the lungs and specially by the interaction of antimony with -SH groups present in erythrocyte membrane cells. In spite of that, there are no studies about antimony enrichment in blood of workers exposed to high vehicle traffic. Port workers are generally exposed to heavy weight vehicle traffic. In Chile the biggest marine port is found in Valparaíso City. In this study antimony in whole blood and its fractions (erythrocytes-plasma and erythrocytes membranes-cytoplasm) of 45 volunteers were determined. The volunteers were port workers from Valparaíso city, and two control groups, one from Valparaíso and another from Quebrada Alvarado, the latter being a rural area located about 100 Km away from Valparaíso. The results demonstrate that port workers are highly impacted by antimony emissions from heavy weight vehicle traffic showing an average concentration of 27 +/- 9 ng Sb kg(-1), 5-10 times higher than the concentration of antimony in the blood of control groups. These are the highest antimony levels in blood ever reported in the literature. The highest antimony percentages (>60%) were always found in the erythrocyte fractions. However, the exposure degree to vehicle traffic is significant over antimony distribution in plasma, erythrocytes and cytoplasm. This results shows that the antimony mass in the erythrocyte membranes, was approximately constant at 1.0 +/- 0.1 ng Sb g(-1) of whole blood in all blood samples analyzed.

  12. NLO+NLL collider bounds, Dirac fermion and scalar dark matter in the B-L model

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, Michael [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Theoretische Physik, Muenster (Germany); Lyonnet, Florian [Southern Methodist University, Dallas, TX (United States); Queiroz, Farinaldo S. [Max-Planck-Institut fuer Kernphysik, Particle and Astroparticle Physics Division, Heidelberg (Germany)

    2017-05-15

    Baryon and lepton numbers being accidental global symmetries of the Standard Model (SM), it is natural to promote them to local symmetries. However, to preserve anomaly-freedom, only combinations of B-L are viable. In this spirit, we investigate possible dark matter realizations in the context of the U(1){sub B-L} model: (i) Dirac fermion with unbroken B-L; (ii) Dirac fermion with broken B-L; (iii) scalar dark matter; (iv) two-component dark matter. We compute the relic abundance, direct and indirect detection observables and confront them with recent results from Planck, LUX-2016, and Fermi-LAT and prospects from XENON1T. In addition to the well-known LEP bound M{sub Z}{sup {sub '}}/g{sub BL} >or similar 7 TeV, we include often ignored LHC bounds using 13 TeV dilepton (dimuon + dielectron) data at next-to-leading order plus next-to-leading logarithmic accuracy. We show that, for gauge couplings smaller than 0.4, the LHC gives rise to the strongest collider limit. In particular, we find M{sub Z}{sup {sub '}}/g{sub BL} > 8.7 TeV for g{sub BL} = 0.3. We conclude that the NLO+NLL corrections improve the dilepton bounds on the Z{sup '} mass and that both dark matter candidates are only viable in the Z{sup '} resonance region, with the parameter space for scalar dark matter being fully probed by XENON1T. Lastly, we show that one can successfully have a minimal two-component dark matter model. (orig.)

  13. High-resolution T{sub 2}-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    Energy Technology Data Exchange (ETDEWEB)

    Hoogendam, Jacob P.; Verheijen, Rene H.M.; Zweemer, Ronald P. [University Medical Centre Utrecht, Department of Gynaecological Oncology, UMC Utrecht Cancer Centre, PO Box 85500, Utrecht (Netherlands); Kalleveen, Irene M.L.; Castro, Catalina S.A. de; Raaijmakers, Alexander J.E.; Bosch, Maurice A.A.J. van den; Klomp, Dennis W.J.; Veldhuis, Wouter B. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2017-03-15

    We studied the feasibility of high-resolution T{sub 2}-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B{sub 1} {sup +} shimming, T{sub 2}-weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T{sub 2}-weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B{sub 1} interference, excessive B{sub 1} under the external antennae and SENSE reconstruction. High-resolution T{sub 2}-weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. (orig.)

  14. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    Science.gov (United States)

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  15. MRI of the cervical spine with T1-weighted multislice flash sequences

    International Nuclear Information System (INIS)

    Schubeus, P.; Sander, B.; Schoerner, W.; Tosch, U.; Lanksch, W.R.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1990-01-01

    A study has been carried out to evaluate contrast and image quality of cervical structures using multislice 2D-flash sequences with long repetition times (TR = 400 ms.) and short echo delay times (TE = 5.8 ms.). The examinations were carried out using ten normals with an MRI of 1.5 Tesla and flip angles of 10, 20, 30, 50, 70 and 90deg. The best contrast between intervertebral disc and surrounding tissue was obtained between 50 and 70deg, best contrast between compact bone and CSF with 10deg. In order to demonstrate degenerative changes of the cervical spine, it appears sensible to use a combination of these angles. The described sequences produce good images of the cervical structures with little image degradation. Compared to T 1 -weighted spin-echo sequences, the method has a number of significant advantages, such as variations in image contrast, higher maximal number of slices, continuous imaging and less imaging time. (orig.) [de

  16. Dark matter in a constrained E6 inspired SUSY model

    International Nuclear Information System (INIS)

    Athron, P.; Harries, D.; Nevzorov, R.; Williams, A.G.

    2016-01-01

    We investigate dark matter in a constrained E 6 inspired supersymmetric model with an exact custodial symmetry and compare with the CMSSM. The breakdown of E 6 leads to an additional U(1) N symmetry and a discrete matter parity. The custodial and matter symmetries imply there are two stable dark matter candidates, though one may be extremely light and contribute negligibly to the relic density. We demonstrate that a predominantly Higgsino, or mixed bino-Higgsino, neutralino can account for all of the relic abundance of dark matter, while fitting a 125 GeV SM-like Higgs and evading LHC limits on new states. However we show that the recent LUX 2016 limit on direct detection places severe constraints on the mixed bino-Higgsino scenarios that explain all of the dark matter. Nonetheless we still reveal interesting scenarios where the gluino, neutralino and chargino are light and discoverable at the LHC, but the full relic abundance is not accounted for. At the same time we also show that there is a huge volume of parameter space, with a predominantly Higgsino dark matter candidate that explains all the relic abundance, that will be discoverable with XENON1T. Finally we demonstrate that for the E 6 inspired model the exotic leptoquarks could still be light and within range of future LHC searches.

  17. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  18. Supersymmetric Dark Matter after LHC Run 1

    CERN Document Server

    Bagnaschi, E.A.; Cavanaugh, R.; Citron, M.; De Roeck, A.; Dolan, M.J.; Ellis, J.R.; Flächer, H.; Heinemeyer, S.; Isidori, G.; Malik, S.; Martínez Santos, D.; Olive, K.A.; Sakurai, K.; de Vries, K.J.; Weiglein, G.

    2015-10-23

    Different mechanisms operate in various regions of the MSSM parameter space to bring the relic density of the lightest neutralino, neutralino_1, assumed here to be the LSP and thus the Dark Matter (DM) particle, into the range allowed by astrophysics and cosmology. These mechanisms include coannihilation with some nearly-degenerate next-to-lightest supersymmetric particle (NLSP) such as the lighter stau (stau_1), stop (stop_1) or chargino (chargino_1), resonant annihilation via direct-channel heavy Higgs bosons H/A, the light Higgs boson h or the Z boson, and enhanced annihilation via a larger Higgsino component of the LSP in the focus-point region. These mechanisms typically select lower-dimensional subspaces in MSSM scenarios such as the CMSSM, NUHM1, NUHM2 and pMSSM10. We analyze how future LHC and direct DM searches can complement each other in the exploration of the different DM mechanisms within these scenarios. We find that the stau_1 coannihilation regions of the CMSSM, NUHM1, NUHM2 can largely be exp...

  19. Normalization of white matter intensity on T1-weighted images of patients with acquired central nervous system demyelination.

    Science.gov (United States)

    Ghassemi, Rezwan; Brown, Robert; Narayanan, Sridar; Banwell, Brenda; Nakamura, Kunio; Arnold, Douglas L

    2015-01-01

    Intensity variation between magnetic resonance images (MRI) hinders comparison of tissue intensity distributions in multicenter MRI studies of brain diseases. The available intensity normalization techniques generally work well in healthy subjects but not in the presence of pathologies that affect tissue intensity. One such disease is multiple sclerosis (MS), which is associated with lesions that prominently affect white matter (WM). To develop a T1-weighted (T1w) image intensity normalization method that is independent of WM intensity, and to quantitatively evaluate its performance. We calculated median intensity of grey matter and intraconal orbital fat on T1w images. Using these two reference tissue intensities we calculated a linear normalization function and applied this to the T1w images to produce normalized T1w (NT1) images. We assessed performance of our normalization method for interscanner, interprotocol, and longitudinal normalization variability, and calculated the utility of the normalization method for lesion analyses in clinical trials. Statistical modeling showed marked decreases in T1w intensity differences after normalization (P < .0001). We developed a WM-independent T1w MRI normalization method and tested its performance. This method is suitable for longitudinal multicenter clinical studies for the assessment of the recovery or progression of disease affecting WM. Copyright © 2014 by the American Society of Neuroimaging.

  20. Supersymmetry and dark matter in light of LHC 2010 and Xenon100 data

    Energy Technology Data Exchange (ETDEWEB)

    Buchmueller, O. [Imperial College, London (United Kingdom). High Energy Physics Group, Blackett Laboratory; Cavanaugh, R. [Fermi National Accelerator Laboratory, Batavia, IL (United States); Illinois Univ., Chicago, IL (United States). Physics Dept.; Colling, D. [Imperial College, London (GB). High Energy Physics Group, Blackett Laboratory] (and others)

    2011-07-15

    We make frequent test analyses of the CMSSM, NUHM1, VCMSSM and mSUGRA parameter spaces taking into account all the public results of searches for supersymmetry using data from the 2010 LHC run and the Xenon100 direct search for dark matter scattering. The LHC data set includes ATLAS and CMS searches for jets+ is not an element of {sub T} events (with or without leptons) and for the heavier MSSM Higgs bosons, and the upper limit on BR(B{sub s} {yields} {mu}{sup +}{mu}{sup -}) including data from LHCb as well as CDF and DO. The absences of signals in the LHC data favour somewhat heavier mass spectra than in our previous analyses of the CMSSM, NUHM1 and VCMSSM, and somewhat smaller dark matter scattering cross sections, all close to or within the pre-LHC 68% CL ranges, but do not impact significantly the favoured regions of the mSUGRA parameter space. We also discuss the impact of the Xenon100 constraint on spin-independent dark matter scattering, stressing the importance of taking into account the uncertainty in the {pi}-nucleon {sigma} term sum {sub {pi}}{sub N}, that affects the spin-independent scattering matrix element, and we make predictions for spin-dependent dark matter scattering. Finally, we discuss briefly the potential impact of the updated predictions for sparticle masses in the CMSSM, NUHM1, VCMSSM and mSUGRA on future e{sup +}e{sup -} colliders. (orig.)

  1. MR imaging of hematopoietic regions in bone marrow of aplastic anemia. Diagnostic usefulness of opposed phase T1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Amano, Maki; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-01-01

    The signal intensity of hematopoietic regions in the marrow of aplastic anemia were investigated on opposed phase T1-weighted images (op-T1WI) with a 0.5-Tesla MR unit. Hematopoietic regions were classified into two groups: low intensity hematopoietic areas (LH) isointense to normal marrow and high intensity hematopoietic regions (HH) with higher intensity than normal marrow on op-T1WI. The signal intensity of LH was significantly lower than that of HH on STIR. LH converted into HH with improvement of laboratory data after therapy, whereas HH decreased with impairment of data. HH were hyperintense to cerebrospinal fluid on op-T1WI. These results indicated that the signal intensity of hematopoietic regions on op-T1WI reflected the cellularity in these regions and that aplastic anemia included hypercellular regions relative to normal marrow. (author).

  2. Dark Matter's secret liaisons: phenomenology of a dark U(1) sector with bound states

    Energy Technology Data Exchange (ETDEWEB)

    Cirelli, Marco; Petraki, Kalliopi; Sala, Filippo [Laboratoire de Physique Théorique et Hautes Energies (LPTHE), UMR 7589 CNRS and UPMC, 4 Place Jussieu, F-75252, Paris (France); Panci, Paolo [CERN Theoretical Physics Department, CERN, Case C01600, CH-1211 Genève (Switzerland); Taoso, Marco, E-mail: marco.cirelli@gmail.com, E-mail: paolo.panci@cern.ch, E-mail: kpetraki@lpthe.jussieu.fr, E-mail: filo.sala@gmail.com, E-mail: m.taoso@csic.es [Instituto de Física Teórica (IFT) UAM/CSIC, calle Nicolás Cabrera 13-15, 28049 Cantoblanco, Madrid (Spain)

    2017-05-01

    Dark matter (DM) charged under a dark U(1) force appears in many extensions of the Standard Model, and has been invoked to explain anomalies in cosmic-ray data, as well as a self-interacting DM candidate. In this paper, we perform a comprehensive phenomenological analysis of such a model, assuming that the DM abundance arises from the thermal freeze-out of the dark interactions. We include, for the first time, bound-state effects both in the DM production and in the indirect detection signals, and quantify their importance for FERMI, AMS-02, and CMB experiments. We find that DM in the mass range 1 GeV to 100 TeV, annihilating into dark photons of MeV to GeV mass, is in conflict with observations. Instead, DM annihilation into heavier dark photons is viable. We point out that the late decays of multi-GeV dark photons can produce significant entropy and thus dilute the DM density. This can lower considerably the dark coupling needed to obtain the DM abundance, and in turn relax the existing constraints.

  3. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  4. Detection of Felis catus gammaherpesvirus 1 (FcaGHV1) in peripheral blood B- and T-lymphocytes in asymptomatic, naturally-infected domestic cats

    Energy Technology Data Exchange (ETDEWEB)

    McLuckie, Alicia J.; Barrs, Vanessa R. [Faculty of Veterinary Science and Marie Bashir Institute for Infectious Diseases and Biosecurity, School of Life and Environmental Sciences, The University of Sydney, NSW 2006 (Australia); Smith, Adrian L. [Advanced Cytometry Facility, University of Sydney/Centenary Institute, NSW 2006 (Australia); Beatty, Julia A., E-mail: julia.beatty@sydney.edu.au [Faculty of Veterinary Science and Marie Bashir Institute for Infectious Diseases and Biosecurity, School of Life and Environmental Sciences, The University of Sydney, NSW 2006 (Australia)

    2016-10-15

    The domestic cat is natural host to both feline immunodeficiency virus and Felis catus gammaherpesvirus 1 (FcaGHV1). Comparative data suggest that these agents might act as synergistic copathogens in feline AIDS-related lymphoma. To identify leucocyte subsets harbouring gammaherpesvirus DNA, whole blood from 5 healthy, FcaGHV1-infected cats was labelled with monoclonal antibodies to feline CD21, CD4, CD8 and CD14 for 4-way fluorescence-activated cell sorting. FcaGHV1gB qPCR was performed on DNA extracted from purified fractions and whole blood longitudinally. FcaGHV1 DNA was detected in CD21+, CD4+, CD8+, but not CD14+ cells. Variation in whole blood load, up to 19,788 copies/10{sup 6}cells, was detected in individual cats over time. FcaGHV1 DNA was undetectable in one cat on one occasion highlighting that qPCR of whole blood from a single time point will not detect all cases of FcaGHV1 infection. Further investigation of the role of FcaGHV1 in feline lymphoid malignancies is warranted. -- Highlights: •FcaGHV1 DNA detected in circulating B and T lymphocytes in domestic cats. •Peripheral FcaGHV1 load fluctuates widely in healthy, chronically-infected cats. •qPCR of blood taken at a single time-point will fail to detect some FcaGHV-infected cats. •A role for FcaGHV1 in FIV-associated lymphoid malignancies is supported.

  5. Detection of Felis catus gammaherpesvirus 1 (FcaGHV1) in peripheral blood B- and T-lymphocytes in asymptomatic, naturally-infected domestic cats

    International Nuclear Information System (INIS)

    McLuckie, Alicia J.; Barrs, Vanessa R.; Smith, Adrian L.; Beatty, Julia A.

    2016-01-01

    The domestic cat is natural host to both feline immunodeficiency virus and Felis catus gammaherpesvirus 1 (FcaGHV1). Comparative data suggest that these agents might act as synergistic copathogens in feline AIDS-related lymphoma. To identify leucocyte subsets harbouring gammaherpesvirus DNA, whole blood from 5 healthy, FcaGHV1-infected cats was labelled with monoclonal antibodies to feline CD21, CD4, CD8 and CD14 for 4-way fluorescence-activated cell sorting. FcaGHV1gB qPCR was performed on DNA extracted from purified fractions and whole blood longitudinally. FcaGHV1 DNA was detected in CD21+, CD4+, CD8+, but not CD14+ cells. Variation in whole blood load, up to 19,788 copies/10 6 cells, was detected in individual cats over time. FcaGHV1 DNA was undetectable in one cat on one occasion highlighting that qPCR of whole blood from a single time point will not detect all cases of FcaGHV1 infection. Further investigation of the role of FcaGHV1 in feline lymphoid malignancies is warranted. -- Highlights: •FcaGHV1 DNA detected in circulating B and T lymphocytes in domestic cats. •Peripheral FcaGHV1 load fluctuates widely in healthy, chronically-infected cats. •qPCR of blood taken at a single time-point will fail to detect some FcaGHV-infected cats. •A role for FcaGHV1 in FIV-associated lymphoid malignancies is supported.

  6. 24-h blood pressure in Space: The dark side of being an astronaut

    NARCIS (Netherlands)

    Karemaker, John M.; Berecki-Gisolf, Janneke

    2009-01-01

    Inflight 24-h profiles of blood pressure (BP) and heart rate (HR) were recorded in 2 ESA-astronauts by automatic upper arm cuff measurements. In one astronaut this was combined with Portapres (TM) continuous finger blood pressure recordings. It was the intention to contrast the latter to 24-h

  7. Probing the Dark Sector with Dark Matter Bound States.

    Science.gov (United States)

    An, Haipeng; Echenard, Bertrand; Pospelov, Maxim; Zhang, Yue

    2016-04-15

    A model of the dark sector where O(few  GeV) mass dark matter particles χ couple to a lighter dark force mediator V, m_{V}≪m_{χ}, is motivated by the recently discovered mismatch between simulated and observed shapes of galactic halos. Such models, in general, provide a challenge for direct detection efforts and collider searches. We show that for a large range of coupling constants and masses, the production and decay of the bound states of χ, such as 0^{-+} and 1^{--} states, η_{D} and ϒ_{D}, is an important search channel. We show that e^{+}e^{-}→η_{D}+V or ϒ_{D}+γ production at B factories for α_{D}>0.1 is sufficiently strong to result in multiple pairs of charged leptons and pions via η_{D}→2V→2(l^{+}l^{-}) and ϒ_{D}→3V→3(l^{+}l^{-}) (l=e,μ,π). The absence of such final states in the existing searches performed at BABAR and Belle sets new constraints on the parameter space of the model. We also show that a search for multiple bremsstrahlung of dark force mediators, e^{+}e^{-}→χχ[over ¯]+nV, resulting in missing energy and multiple leptons, will further improve the sensitivity to self-interacting dark matter.

  8. The Helmholtz Hierarchy: phase space statistics of cold dark matter

    International Nuclear Information System (INIS)

    Tassev, Svetlin V.

    2011-01-01

    We present a new formalism to study large-scale structure in the universe. The result is a hierarchy (which we call the ''Helmholtz Hierarchy'') of equations describing the phase space statistics of cold dark matter (CDM). The hierarchy features a physical ordering parameter which interpolates between the Zel'dovich approximation and fully-fledged gravitational interactions. The results incorporate the effects of stream crossing. We show that the Helmholtz hierarchy is self-consistent and obeys causality to all orders. We present an interpretation of the hierarchy in terms of effective particle trajectories

  9. effect of continous light and darkness exposures on the pituitary

    African Journals Online (AJOL)

    Dr Olaleye

    The effects of constant light and dark exposure of pubertal male rats on the pituitary-gonadal axis and thyroid activity were studied. ... In the rats exposed to continuous light, the weight of the thyroid gland increased significantly (P<0.02) and the serum level of T4 also ... 3minutes) per day when food in the cages was being.

  10. Comparative study of standard space and real space analysis of quantitative MR brain data.

    Science.gov (United States)

    Aribisala, Benjamin S; He, Jiabao; Blamire, Andrew M

    2011-06-01

    To compare the robustness of region of interest (ROI) analysis of magnetic resonance imaging (MRI) brain data in real space with analysis in standard space and to test the hypothesis that standard space image analysis introduces more partial volume effect errors compared to analysis of the same dataset in real space. Twenty healthy adults with no history or evidence of neurological diseases were recruited; high-resolution T(1)-weighted, quantitative T(1), and B(0) field-map measurements were collected. Algorithms were implemented to perform analysis in real and standard space and used to apply a simple standard ROI template to quantitative T(1) datasets. Regional relaxation values and histograms for both gray and white matter tissues classes were then extracted and compared. Regional mean T(1) values for both gray and white matter were significantly lower using real space compared to standard space analysis. Additionally, regional T(1) histograms were more compact in real space, with smaller right-sided tails indicating lower partial volume errors compared to standard space analysis. Standard space analysis of quantitative MRI brain data introduces more partial volume effect errors biasing the analysis of quantitative data compared to analysis of the same dataset in real space. Copyright © 2011 Wiley-Liss, Inc.

  11. Annihilation cross section of Kaluza Klien dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rakesh, E-mail: rakesh-sharma-ujn@yahoo.co.in [Northern India Textile Research Association Technical Campus Ghaziabad U.P. 201002 (India); Upadhyaya, G. K., E-mail: gopalujjain@yahoo.co.in; Sharma, S. [School of Studies in Physics, Vikram University Ujjain, M.P. 456010 India (India)

    2015-07-31

    The question as to how this universe came into being and as to how it has evolved to its present stage, is an old question. The answer to this question unfolds many secrets regarding fundamental particles and forces between them. Theodor Kaluza proposed the concept that the universe is composed of more than four space-time dimensions. In his work, electromagnetism is united with gravity. Various extra dimension formulations have been proposed to solve a variety of problems. Recently, the idea of more than four space time dimensions is applied to the search for particle identity of dark matter (DM). Signature of dark matter can be revealed by analysis of very high energy electrons which are coming from outer space. We investigate recent advancement in the field of dark matter search with reference to very high energy electrons from outer space [1-8].

  12. Treatment of hepatocellular carcinoma adjacent to large blood vessels using 1.5T MRI-guided percutaneous radiofrequency ablation combined with iodine-125 radioactive seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Zheng-Yu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Chen, Jin, E-mail: snow8968851@163.com [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Deng, Xiu-Fen, E-mail: dxf197286@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2012-11-15

    Objective: The objective is to study the technology associated with and feasibility of the treatment of hepatocellular carcinoma (HCC) adjacent to large blood vessels using 1.5T MRI-guided radiofrequency ablation combined with iodine-125 (I-125) radioactive seed implantation. Methods: Sixteen patients with a total of 24 HCC lesions (average maximum diameter: 2.35 {+-} 1.03 cm) were pathologically confirmed by biopsy or clinically diagnosed received 1.5T MRI-guided percutaneous radiofrequency ablation (RFA) treatment. Each patient had one lesion adjacent to large blood vessels ({>=}3 mm); after the ablation, I-125 radioactive seeds were implanted in the portions of the lesions that were adjacent to the blood vessels. Results: All the ablations and I-125 radioactive seed implantations were successful; a total of 118 seeds were implanted. The ablated lesions exhibited hypointense signals on the T2WI sequence with a thin rim of hyperintense signals; they also exhibited significant hyperintense signals on the T1WI sequence with clear boundaries. The average follow-up period was 11.1 {+-} 6.2 months. There were 23 complete responses and one partial response in the 24 lesions. The alpha-fetoprotein (AFP) levels of the patients significantly decreased. Conclusion: The 1.5T MRI-guided RFA combined with I-125 radioactive seed implantation for the treatment of HCC adjacent to large blood vessels is an effective technology.

  13. Dark Matter

    International Nuclear Information System (INIS)

    Holt, S. S.; Bennett, C. L.

    1995-01-01

    These proceedings represent papers presented at the Astrophysics conference in Maryland, organized by NASA Goddard Space Flight Center and the University of Maryland. The topics covered included low mass stars as dark matter, dark matter in galaxies and clusters, cosmic microwave background anisotropy, cold and hot dark matter, and the large scale distribution and motions of galaxies. There were eighty five papers presented. Out of these, 10 have been abstracted for the Energy Science and Technology database

  14. [Immunotoxicologic assessment of genetically modified drought-resistant wheat T349 with GmDREB1].

    Science.gov (United States)

    Liang, Chun-lai; Li, Yong-ning; Zhang, Xiao-peng; Song, Yan; Wang, Wei; Fang, Jin; Cui, Wen-ming; Jia, Xu-dong

    2012-06-01

    To assess the immunotoxicologic effects of genetically modified drought resistant wheat T349 with GmDREB1 gene. A total of 250 female BALB/c mice (6-8 week-old, weight 18-22 g) were divided into five large groups (50 mice for each large group) by body weight randomly. In each large group, the mice were divided into five groups (10 mice for each group) by body weight randomly, which were set as negative control group, common wheat group, parental wheat group, genetically modified wheat group and cyclophosphamide positive control group, respectively. Mice in negative control and positive control group were fed with feedstuff AIN-93G, mice in common wheat group, non-genetically modified parental wheat group and genetically modified wheat group were fed with feedstuffs added corresponding wheat (proportion up to 76%) for 30 days, then body weight, organ coefficient of spleen and thymus, peripheral blood lymphocytes phenotyping, serum cytokine, serum immunoglobulin, antibody plaque-forming cell (PFC), serum 50% hemolytic value (HC50), mitogen-induced splenocyte proliferation, delayed-type hypersensitivity (DTH) reaction and phagocytic activities of phagocytes were detected respectively. After 30 days raise, among negative control group, common wheat group, non-genetically modified parental wheat group, genetically modified wheat group and cyclophosphamide positive control group, mice body weight were (21.0±0.3), (20.4±0.7), (21.1±1.0), (21.1±1.0), (19.4±1.0) g, respectively (F=7.47, Pgenetically modified drought-resistant wheat T349 was substantially equivalent to parental wheat in the effects on immune organs and immunologic functions of mice, and it didn't show immunotoxicity.

  15. “Hot cross bun” sign in multiple system atrophy with predominant cerebellar ataxia: A comparison between proton density-weighted imaging and T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kasahara, Seiko, E-mail: nuun077@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Miki, Yukio, E-mail: yukio.miki@med.osaka-cu.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545–8585 (Japan); Kanagaki, Mitsunori, E-mail: mitsuk@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Kondo, Takayuki, E-mail: kondotak@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Yamamoto, Akira, E-mail: yakira@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Morimoto, Emiko, E-mail: foresta@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Ito, Hidefumi, E-mail: itohid@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Takahashi, Ryosuke, E-mail: ryosuket@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); and others

    2012-10-15

    Objective: To investigate whether proton density-weighted imaging can detect the “hot cross bun” sign in the pons in multiple system atrophy with predominant cerebellar ataxia significantly better than T2-weighted imaging at 3 T. Methods: Sixteen consecutive patients with multiple system atrophy with predominant cerebellar ataxia according to the Consensus Criteria were reviewed. Axial unenhanced proton density-weighted imaging and T2-weighted imaging were obtained using a dual-echo fast spin-echo sequence at 3 T. Two neuroradiologists independently evaluated visualisation of the abnormal pontine signal using a 4-point visual grade from Grade 0 (no “hot cross bun” sign) to Grade 3 (prominent “hot cross bun” sign on two or more sequential slices). Differences in grade between proton density-weighted imaging and T2-weighted imaging were statistically analysed using the Wilcoxon signed-rank test. Results: In 11 patients (69%), a higher grade was given for proton density-weighted imaging than T2-weighted imaging. In 1 patient (6%), grades were the same (Grade 3) on both images. In the remaining 4 patients (25%), signal abnormalities were not detected on either image (Grade 0). The “hot cross bun” sign was thus observed significantly better on proton density-weighted imaging than on T2-weighted imaging (P = 0.001). Conclusions: The “hot cross bun” sign considered diagnostic for multiple system atrophy with predominant cerebellar ataxia is significantly better visualised on proton density-weighted imaging than on T2-weighted imaging at 3 T.

  16. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Radlbauer, Rudolf, E-mail: rudolf.radlbauer@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Lomoschitz, Friedrich, E-mail: friedrich.lomoschitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Salomonowitz, Erich, E-mail: erich.salomonowitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Eberhardt, Knut E., E-mail: info@mrt-kompetenzzentrum.d [MRT Competence Center Schloss Werneck, Balthasar-Neumann-Platz 2, 97440 Werneck (Germany); Stadlbauer, Andreas, E-mail: andi@nmr.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen (Germany)

    2010-08-15

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  17. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    International Nuclear Information System (INIS)

    Radlbauer, Rudolf; Lomoschitz, Friedrich; Salomonowitz, Erich; Eberhardt, Knut E.; Stadlbauer, Andreas

    2010-01-01

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  18. [The use of the T2-weighted turbo-spin-echo sequence in studying the neurocranium. A comparison with the conventional T2-weighted spin-echo sequence].

    Science.gov (United States)

    Siewert, C; Hosten, N; Felix, R

    1994-07-01

    T2-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neurocranium. We evaluated fast spin-echo T2-weighted imaging (TT2) of the neurocranium in comparison to conventional spin-echo T2-weighted imaging (T2). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher in TT2 than in T2 (with the exception of gray-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT2, Parkinson patients have to be examined by conventional T2. If these limitations are taken into account, fast spin-echo T2-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T2-weighting achieved in a short acquisition time.

  19. Hippocampal Microbleed on a Post-Mortem T2*-Weighted Gradient-Echo 7.0-Tesla Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    J. De Reuck

    2011-09-01

    Full Text Available The present post-mortem study of a brain from an Alzheimer patient showed on a T2*-weighted gradient-echo 7.0-T MRI of a coronal brain section a hyposignal in the hippocampus, suggesting a microbleed. On the corresponding histological examination, only iron deposits around the granular cellular layer and in blood vessel walls of the hippocampus were observed without evidence of a bleeding. This case report illustrates that the detection of microbleeds on MRI has to be interpreted with caution.

  20. Validation of highly accelerated real-time cardiac cine MRI with radial k-space sampling and compressed sensing in patients at 1.5T and 3T.

    Science.gov (United States)

    Haji-Valizadeh, Hassan; Rahsepar, Amir A; Collins, Jeremy D; Bassett, Elwin; Isakova, Tamara; Block, Tobias; Adluru, Ganesh; DiBella, Edward V R; Lee, Daniel C; Carr, James C; Kim, Daniel

    2018-05-01

    To validate an optimal 12-fold accelerated real-time cine MRI pulse sequence with radial k-space sampling and compressed sensing (CS) in patients at 1.5T and 3T. We used two strategies to reduce image artifacts arising from gradient delays and eddy currents in radial k-space sampling with balanced steady-state free precession readout. We validated this pulse sequence against a standard breath-hold cine sequence in two patient cohorts: a myocardial infarction (n = 16) group at 1.5T and chronic kidney disease group (n = 18) at 3T. Two readers independently performed visual analysis of 68 cine sets in four categories (myocardial definition, temporal fidelity, artifact, noise) on a 5-point Likert scale (1 = nondiagnostic, 2 = poor, 3 = adequate or moderate, 4 = good, 5 = excellent). Another reader calculated left ventricular (LV) functional parameters, including ejection fraction. Compared with standard cine, real-time cine produced nonsignificantly different visually assessed scores, except for the following categories: 1) temporal fidelity scores were significantly lower (P = 0.013) for real-time cine at both field strengths, 2) artifacts scores were significantly higher (P = 0.013) for real-time cine at both field strengths, and 3) noise scores were significantly (P = 0.013) higher for real-time cine at 1.5T. Standard and real-time cine pulse sequences produced LV functional parameters that were in good agreement (e.g., absolute mean difference in ejection fraction cine MRI pulse sequence using radial k-space sampling and CS produces good to excellent visual scores and relatively accurate LV functional parameters in patients at 1.5T and 3T. Magn Reson Med 79:2745-2751, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. WIMP Dark Matter and Unitarity-Conserving Inflation via a Gauge Singlet Scalar

    International Nuclear Information System (INIS)

    Kahlhoefer, Felix; McDonald, John

    2015-07-01

    A gauge singlet scalar with non-minimal coupling to gravity can drive inflation and later freeze out to become cold dark matter. We explore this idea by revisiting inflation in the singlet direction (S-inflation) and Higgs Portal Dark Matter in light of the Higgs discovery, limits from LUX and observations by Planck. We show that large regions of parameter space remain viable, so that successful inflation is possible and the dark matter relic abundance can be reproduced. Moreover, the scalar singlet can stabilise the electroweak vacuum and at the same time overcome the problem of unitarity-violation during inflation encountered by Higgs Inflation, provided the singlet is a real scalar. The 2-σ Planck upper bound on n s imposes that the singlet mass is below 2 TeV, so that almost the entire allowed parameter range can be probed by XENON1T.

  2. Isolation and partial characterization of peripheral blood CD4+ T cell clones expressing γδT cell receptors

    International Nuclear Information System (INIS)

    Kyoizumi, Seishi; Akiyama, Mitoshi; Hirai, Yuko; Kusunoki, Yoichiro.

    1990-06-01

    Rare T cell clones bearing both CD4 and T cell receptors (TCRγ and TCRδ) were obtained from human peripheral blood by cell sorting using anti-CD4 and anti-TCRδ1 antibodies. All the clones established were reactive with anti-TCRγδ1 antibody, whereas only about 20 % of the clones showed reactivity with anti-δTCS1 antibody. Unlike CD4 + T cells bearing TCRαβ, all the clones tested were lectin-dependent and showed CD3 antibody-redirected cytolytic activity. About 60 % exhibited natural killer cell-like activity. Immunoprecipitation analysis of TCRγδ showed that each clone expressed either a disulfide-linked or nondisulfide-linked heterodimer consisting of 37-44 kilodalton TCRγ and TCRδ chains. Southern blot analyses of TCRγ and TCRδ genes revealed some identical rearrangement patterns, suggesting the limited heterogeneity of CD4 + TCRγδ + T cells in peripheral blood. (author)

  3. The value of diffusion-weighted imaging in combination with T2-weighted imaging for rectal cancer detection

    International Nuclear Information System (INIS)

    Rao Shengxiang; Zeng Mengsu; Chen Caizhong; Li Renchen; Zhang Shujie; Xu Jianming; Hou Yingyong

    2008-01-01

    Objective: To evaluate the clinical value of diffusion-weighted imaging (DWI) in combination with T 2 -weighted imaging (T 2 WI) for the detection of rectal cancer as compared with T 2 WI alone. Materials and methods: Forty-five patients with rectal cancer and 20 without rectal cancer underwent DWI with parallel imaging and T 2 WI on a 1.5 T scanner. Images were independently reviewed by two readers blinded to the results to determine the detectability of rectal cancer. The detectability of T 2 W imaging without and with DW imaging was assessed by means of receiver operating characteristic analysis. The interobserver agreement between the two readers was calculated with kappa statistics. Results: The ROC analysis showed that each of two readers achieved more accurate results with T 2 W imaging combined with DW imaging than with T 2 W imaging alone significantly. The A z values for the two readers for each T 2 WI and T 2 WI combined with DWI were 0.918 versus 0.991 (p = 0.0494), 0.934 versus 0.997 (p = 0.0475), respectively. The values of kappa were 0.934 for T 2 WI and 0.948 for T 2 WI combined with DWI between the two readers. Conclusion: The addition of DW imaging to conventional T 2 W imaging provides better detection of rectal cancer

  4. Seminal vesicle invasion in prostate cancer: prediction with combined T2-weighted and diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Ren, Jing; Huan, Yi; Ge, YaLi; Chang, YingJuan; Yin, Hong; Sun, LiJun; Wang, He

    2009-01-01

    The aim of this study was to evaluate the usefulness of diffusion-weighted imaging (DWI) in detecting seminal vesicle invasion (SVI). A total of 283 patients underwent conventional MRI and DWI before prostate cancer surgery. The apparent diffusion coefficient (ADC) values of all PCa foci, SVI and seminal vesicle were measured. T2 images alone and then T2 images combined with DWI were scored for the likelihood of SVI. The area under the receiver operating characteristic curve (AUC) was used to assess accuracy. Statistical significance was inferred at P<0.05. On pathological analysis, 39 patients had SVI. The ADC values of SVI were significantly lower than those of SV. The AUC for T2-weighted imaging plus DW imaging (0.897) was significantly larger (P<0.05) than that for T2-weighted imaging alone (0.779). T2 images combined with DWI shows significantly higher accuracy than T2-weighted imaging alone in the detection of SVI. (orig.)

  5. Right-handed neutrino dark matter in a U(1) extension of the Standard Model

    Science.gov (United States)

    Cox, Peter; Han, Chengcheng; Yanagida, Tsutomu T.

    2018-01-01

    We consider minimal U(1) extensions of the Standard Model in which one of the right-handed neutrinos is charged under the new gauge symmetry and plays the role of dark matter. In particular, we perform a detailed phenomenological study for the case of a U(1)(B‑L)3 flavoured B‑L symmetry. If perturbativity is required up to high-scales, we find an upper bound on the dark matter mass of mχlesssim2 TeV, significantly stronger than that obtained in simplified models. Furthermore, if the U(1)(B‑L)3 breaking scalar has significant mixing with the SM Higgs, there are already strong constraints from direct detection. On the other hand, there remains significant viable parameter space in the case of small mixing, which may be probed in the future via LHC Z' searches and indirect detection. We also comment on more general anomaly-free symmetries consistent with a TeV-scale RH neutrino dark matter candidate, and show that if two heavy RH neutrinos for leptogenesis are also required, one is naturally led to a single-parameter class of U(1) symmetries.

  6. Persistence of Space Radiation Induced Cytogenetic Damage in the Blood Lymphocytes of Astronauts

    Science.gov (United States)

    George, Kerry

    Cytogenetic damage in astronaut's peripheral blood lymphocytes is a useful in vivo marker of space radiation induced damage. Moreover, if radiation induced chromosome translocations persist in peripheral blood lymphocytes for many years, as has been assumed, they could potentially be used to measure retrospective doses or prolonged low dose rate exposures. However, as more data becomes available, evidence suggests that the yield of translocations may decline with time after irradiation, at least for space radiation exposures. We present our latest follow-up measurements of chromosome aberrations in astronauts' blood lymphocytes assessed by FISH painting and collected at various times beginning directly after return from space to several years after flight. For most individuals the analysis of individual time-courses for translocations revealed a temporal decline of yields with different half-lives. Since the level of stable aberrations depends on the interplay between natural loss of circulating T-lymphocytes and replenishment from the stem or progenitor cells, the differences in the rates of decay could be explained by inter-individual variation in lymphocyte turn over. Biodosimetry estimates derived from cytogenetic analysis of samples collected a few days after return to earth lie within the range expected from physical dosimetry. However, a temporal decline in yields may indicate complications with the use of stable aberrations for retrospective dose reconstruction, and the differences in the decay time may reflect individual variability in risk from space radiation exposure. In addition, limited data on multiple flights show a lack of correlation between time in space and translocation yields. Data from one crewmember who has participated in two separate long-duration space missions and has been followed up for over 10 years provide limited information on the effect of repeat flights and show a possible adaptive response to space radiation exposure.

  7. Molecular Dynamic Simulation of Space and Earth-Grown Crystal Structures of Thermostable T1 Lipase Geobacillus zalihae Revealed a Better Structure.

    Science.gov (United States)

    Ishak, Siti Nor Hasmah; Aris, Sayangku Nor Ariati Mohamad; Halim, Khairul Bariyyah Abd; Ali, Mohd Shukuri Mohamad; Leow, Thean Chor; Kamarudin, Nor Hafizah Ahmad; Masomian, Malihe; Rahman, Raja Noor Zaliha Raja Abd

    2017-09-25

    Less sedimentation and convection in a microgravity environment has become a well-suited condition for growing high quality protein crystals. Thermostable T1 lipase derived from bacterium Geobacillus zalihae has been crystallized using the counter diffusion method under space and earth conditions. Preliminary study using YASARA molecular modeling structure program for both structures showed differences in number of hydrogen bond, ionic interaction, and conformation. The space-grown crystal structure contains more hydrogen bonds as compared with the earth-grown crystal structure. A molecular dynamics simulation study was used to provide insight on the fluctuations and conformational changes of both T1 lipase structures. The analysis of root mean square deviation (RMSD), radius of gyration, and root mean square fluctuation (RMSF) showed that space-grown structure is more stable than the earth-grown structure. Space-structure also showed more hydrogen bonds and ion interactions compared to the earth-grown structure. Further analysis also revealed that the space-grown structure has long-lived interactions, hence it is considered as the more stable structure. This study provides the conformational dynamics of T1 lipase crystal structure grown in space and earth condition.

  8. [Value of intravoxel incoherent motion diffusion-weighted imaging in differential diagnosis of benign and malignant hepatic lesions and blood perfusion evaluation].

    Science.gov (United States)

    Ying, M L; Xiao, W W; Xu, S L; Shu, J E; Pan, J F; Fu, J F; Lu, J H; Pan, Y H; Jiang, Y

    2016-11-20

    Objective: To investigate the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in the differential diagnosis and blood perfusion evaluation of benign and malignant hepatic lesions. Methods: A retrospective analysis was performed for 86 patients (96 lesions) with pathologically or clinically confirmed hepatic lesions or hepatic lesions diagnosed based on follow-up results, among whom 48 had malignant lesions (53 lesions) and 38 had benign lesions (43 lesions). The patients underwent conventional magnetic resonance (MR) plain scan, contrast-enhanced scan, and diffusion-weighted imaging (DWI) with different b values (b = 0, 50, 100, 150, 200, 400, 600, 800, 1 000, and 1 200 s/mm 2 ) to determine the parameters of the double exponential model for intravoxel incoherent motion (IVIM): fast diffusion coefficient Dfast, slow diffusion coefficient Dslow, and percentage of fast-diffusion constituent F value. The patients were divided into groups according to the blood supply to lesions on conventional MR plain scan and contrast-enhanced scan, and there were 47 lesions in abundant blood supply group and 49 in poor blood supply group. The data for analysis were Dfast, Dslow, and F values of benign/malignant lesion groups and abundant/poor blood supply groups. The independent samples t-test was used for statistical analysis; the independent samples non-parametric test Mann-Whitney U test was used for the comparison of F value; the receiver operating characteristic (ROC) curve was used to evaluate the value of above parameters in the differentiation of benign and malignant lesions and blood supply evaluation. Results: Compared with the malignant lesion group, the benign lesion group had significantly higher Dslow, and F values ( P benign and malignant hepatic lesions, and F value can show blood perfusion in benign and malignant hepatic lesions without the need for contrast-enhanced scan, which provides a reference for the qualitative diagnosis of liver

  9. Auschwitz dark tourism -kohteena

    OpenAIRE

    Kuusimäki, Karita

    2015-01-01

    Dark tourism eli synkkä matkailu on matkustamista kohteisiin, jotka liittyvät jollain tavalla kuolemaan, kauhuun, kärsimykseen tai katastrofeihin. Dark tourism on ilmiönä suhteellisen tuore, mutta sen historia juontaa juurensa jo antiikin ajan gladiaattoritaisteluihin. Ilmiötä on tutkittu jonkin verran ja siitä on tehty muutamia opinnäytetöitä. Yksi tunnetuimmista ja eniten vierailluista dark tourism -kohteista on Auschwitzin keskitysleiri. Auschwitz aloitti toimintansa vuonna 1940 ja le...

  10. H I CLOUDS IN THE M81 FILAMENT AS DARK MATTER MINIHALOS-A PHASE-SPACE MISMATCH

    International Nuclear Information System (INIS)

    Chynoweth, Katie M.; Langston, Glen I.; Holley-Bockelmann, Kelly

    2011-01-01

    Cosmological galaxy formation models predict the existence of dark matter minihalos surrounding galaxies and in filaments connecting groups of galaxies. The more massive of these minihalos are predicted to host H I gas that should be detectable by current radio telescopes such as the Robert C. Byrd Green Bank Telescope (GBT). We observed the region including the M81/M82 and NGC 2403 galaxy groups, searching for observational evidence of an H I component associated with dark matter halos within the 'M81 Filament', using the GBT. The map covers an 8. 0 7 x 21. 0 3 (480 kpc x 1.2 Mpc) region centered between the M81/M82 and NGC 2403 galaxy groups. Our observations cover a wide velocity range, from -890 to 1320 km s -1 , which spans much of the range predicted by cosmological N-body simulations for dark matter minihalo velocities. Our search is not complete in the velocity range -210 to 85 km s -1 , containing Galactic emission and the HVC Complex A. For an H I cloud at the distance of M81, with a size ≤10 kpc, our average 5σ mass detection limit is 3.2 x 10 6 M sun , for a linewidth of 20 km s -1 . We compare our observations to two large cosmological N-body simulations and find that the simulation predicts a significantly greater number of detectable minihalos than are found in our observations, and that the simulated minihalos do not match the phase space of observed H I clouds. These results place strong constraints on the H I gas that can be associated with dark matter halos. Our observations indicate that the majority of extragalactic H I clouds with a mass greater than 10 6 M sun are likely to be generated through tidal stripping caused by galaxy interactions.

  11. Dark Matter Annihilation in The Galactic Center As Seen by the Fermi Gamma Ray Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Hooper, Dan; /Fermilab /Chicago U., Astron. Astrophys. Ctr.; Goodenough, Lisa; /New York U.

    2010-10-01

    We analyze the first two years of data from the Fermi Gamma Ray Space Telescope from the direction of the inner 10{sup o} around the Galactic Center with the intention of constraining, or finding evidence of, annihilating dark matter. We find that the morphology and spectrum of the emission between 1.25{sup o} and 10{sup o} from the Galactic Center is well described by a the processes of decaying pions produced in cosmic ray collisions with gas, and the inverse Compton scattering of cosmic ray electrons in both the disk and bulge of the Inner Galaxy, along with gamma rays from known points sources in the region. The observed spectrum and morphology of the emission within approximately 1.25{sup o} ({approx}175 parsecs) of the Galactic Center, in contrast, cannot be accounted for by these processes or known sources. We find that an additional component of gamma ray emission is clearly present which is highly concentrated around the Galactic Center, but is not point-like in nature. The observed morphology of this component is consistent with that predicted from annihilating dark matter with a cusped (and possibly adiabatically contracted) halo distribution ({rho} {proportional_to} r{sup -1.34{+-}0.04}). The observed spectrum of this component, which peaks at energies between 2-4 GeV (in E{sup 2} units), is well fit by that predicted for a 7.3-9.2 GeV dark matter particle annihilating primarily to tau leptons with a cross section in the range of <{sigma}{nu}> = 3.3 x 10{sup -27} to 1.5 x 10{sup -26} cm{sup 3}/s, depending on how the dark matter distribution is normalized. We discuss other possible sources for this component, but argue that they are unlikely to account for the observed emission.

  12. Dark Energy and Structure Formation

    International Nuclear Information System (INIS)

    Singh, Anupam

    2010-01-01

    We study the gravitational dynamics of dark energy configurations. We report on the time evolution of the dark energy field configurations as well as the time evolution of the energy density to demonstrate the gravitational collapse of dark energy field configurations. We live in a Universe which is dominated by Dark Energy. According to current estimates about 75% of the Energy Density is in the form of Dark Energy. Thus when we consider gravitational dynamics and Structure Formation we expect Dark Energy to play an important role. The most promising candidate for dark energy is the energy density of fields in curved space-time. It therefore become a pressing need to understand the gravitational dynamics of dark energy field configurations. We develop and describe the formalism to study the gravitational collapse of fields given any general potential for the fields. We apply this formalism to models of dark energy motivated by particle physics considerations. We solve the resulting evolution equations which determine the time evolution of field configurations as well as the dynamics of space-time. Our results show that gravitational collapse of dark energy field configurations occurs and must be considered in any complete picture of our universe.

  13. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Energy Technology Data Exchange (ETDEWEB)

    Aalseth, C.E.; et al.

    2017-07-25

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\\gt3\\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $\

  14. Gravitational wave from dark sector with dark pion

    Energy Technology Data Exchange (ETDEWEB)

    Tsumura, Koji [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan); Yamada, Masatoshi [Institut für Theoretische Physik, Universität Heidelberg, Philosophenweg 16, 69120 Heidelberg (Germany); Yamaguchi, Yuya, E-mail: ko2@gauge.scphys.kyoto-u.ac.jp, E-mail: m.yamada@thphys.uni-heidelberg.de, E-mail: yy@particle.sci.hokudai.ac.jp [Department of Physics, Faculty of Science, Hokkaido University, Sapporo 060-0810 (Japan)

    2017-07-01

    In this work, we investigate the spectra of gravitational waves produced by chiral symmetry breaking in dark quantum chromodynamics (dQCD) sector. The dark pion (π) can be a dark matter candidate as weakly interacting massive particle (WIMP) or strongly interacting massive particle (SIMP). For a WIMP scenario, we introduce the dQCD sector coupled to the standard model (SM) sector with classical scale invariance and investigate the annihilation process of the dark pion via the 2π → 2 SM process. For a SIMP scenario, we investigate the 3π → 2π annihilation process of the dark pion as a SIMP using chiral perturbation theory. We find that in the WIMP scenario the gravitational wave background spectra can be observed by future space gravitational wave antennas. On the other hand, when the dark pion is the SIMP dark matter with the constraints for the chiral perturbative limit and pion-pion scattering cross section, the chiral phase transition becomes crossover and then the gravitational waves are not produced.

  15. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanharawi, Imane El; Tzarouchi, Loukia [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Cardoen, Liesbeth [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude [Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Hopital Robert Debre, APHP, Service d' Endocrinologie Pediatrique, Paris (France); Elmaleh-Berges, Monique [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Alison, Marianne [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France)

    2017-05-15

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting. (orig.)

  16. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis.

    Science.gov (United States)

    El Sanharawi, Imane; Tzarouchi, Loukia; Cardoen, Liesbeth; Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude; Elmaleh-Berges, Monique; Alison, Marianne

    2017-05-01

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting.

  17. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  18. Appearance of normal brain maturation on 1.5-T MR images

    International Nuclear Information System (INIS)

    Barkovich, A.J.; Kjos, B.; Jackson, D.E. Jr.; Norman, D.

    1987-01-01

    To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of myelination, as demonstrated by histochemical methods. T1-weighted images were most useful to monitor normal brain development in the first 6 to 8 months of life; T2-weighted images were more useful after 6 months. The milestones in the MR appearance of normal maturation of the brain are presented. The milestones in the MR appearance of normal maturation of the brain are presented. Persistent areas of long T2 relaxation times are seen superior and dorsal to the ventricular trigone in all infants examined and should not be mistaken for ischemic change

  19. Visual astronomy under dark skies a new approach to observing deep space

    CERN Document Server

    Cooke, Antony

    2005-01-01

    Modern astronomical telescopes, along with other advances in technology, have brought the deep sky - star clusters, nebulae and the galaxies - within reach of amateur astronomers. And it isn't even necessary to image many of these deep-sky objects in order to see them; they are within reach of visual observers using modern techniques and enhancement technology. The first requirement is truly dark skies; if you are observing from a light-polluted environment you need Tony Cooke's book, Visual Astronomy in the Suburbs. Given a site with clear, dark night skies everything else follows… this book will provide the reader with everything he needs to know about what to observe, and using some of today's state-of-the-art technique and commercial equipment, how to get superb views of faint and distant astronomical objects.

  20. Assessing the effect of weight and weight loss in obese persons with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Bradley Curtis

    2008-10-01

    Full Text Available Bradley Curtis1, Risa P Hayes1, Sheri Fehnel2, Laurie Zografos21Global Health Outcomes, Eli Lilly and Co, Indianapolis, IN, USA; 2RTI Health Solutions, Research Triangle Park, NC, USAAbstract: The objective of this study was to assess specific areas of life in which obesity affects individuals with type 2 diabetes mellitus (T2DM, and changes that obese persons with T2DM experience with weight loss of varying degrees. Thirty in-depth interviews were conducted in persons identified as: age ≥40 years, diagnosed with T2DM for ≥2 years, on oral antihyperglycemic medications >3 months, BMI 30–35 kg/m2, having attempted to lose weight in the last 2 years. Participants (60% female, mean age 53 years, 53% Caucasian, mean BMI 32.2 kg/m2 agreed that 5% weight loss, while not reflective of an ultimate goal, would be meaningful and important; benefits were expected to accrue in physical functioning, self-confidence, blood glucose levels, and motivation to keep losing weight. Participants reported the greatest effect of weight loss on energy, physical activity, mobility, pain, and clothes/appearance. Participants reported weight affecting mood, with feelings of depression and frustration most commonly described. This research indicates that weight loss is likely to affect health-related quality of life in obese individuals with T2DM. Given the purported weight loss benefits of many emerging diabetic medications, it will be important to include measures of weight-related quality of life in future clinical trials of these agents.Keywords: health-related quality of life, obesity, type 2 diabetes, weight loss, patient-reported outcomes

  1. Dark matter halos with cores from hierarchical structure formation

    International Nuclear Information System (INIS)

    Strigari, Louis E.; Kaplinghat, Manoj; Bullock, James S.

    2007-01-01

    We show that dark matter emerging from late decays (z or approx. 0.1 Mpc), and simultaneously generates observable constant-density cores in small dark matter halos. We refer to this class of models as meta-cold dark matter (mCDM), because it is born with nonrelativistic velocities from the decays of cold thermal relics. The constant-density cores are a result of the low phase-space density of mCDM at birth. Warm dark matter cannot produce similar size phase-space limited cores without saturating the Lyα power spectrum bounds. Dark matter-dominated galaxy rotation curves and stellar velocity dispersion profiles may provide the best means to discriminate between mCDM and CDM. mCDM candidates are motivated by the particle spectrum of supersymmetric and extra dimensional extensions to the standard model of particle physics

  2. Fusion of High b-valve diffusion-weighted and T2-weighted MR images improves identification of lymph nodes in the pelvis

    International Nuclear Information System (INIS)

    Mir, N.; Sohaib, S.A.; Collins, D.; Koh, D.M.

    2010-01-01

    Full text: Accurate identification of lymph nodes facilities nodal assessment by size, morphological or MR lymphographic criteria. We compared the MR detection of lymph nodes in patients with pelvic cancers using T2-weighted imaging, and fusion of diffusion-weighted imaging (OWl) and T2-weighted imaging. Twenty patients with pelvic tumours underwent 5-mm axial T2-weighted and OWl (b-values 0-750 s/mm 2 ) on a L 5T system. Fusion images of b = 750 s/mm 2 diffusion-weighted MR and T2-weighted images were created. Two radiologists evaluated in consensus the T2-weighted images and fusion images independently. For each image set, the location and diameter of pelvic nodes were recorded, and nodal visibility was scored using a 4-point scale (0-3). Nodal visualisation was compared using Relative to an Identified Distribution (RIDIT) analysis. The mean RIDIT score describes the probability that a randomly selected node will be better visualised relative to the other image set. One hundred fourteen pelvic nodes (mean 5.9 mm; 2-10 mm) were identified on T2-weighted images and 161 nodes (mean 4.3 mm; 2-10 mm) on fusion images. Using fusion images, 47 additional nodes were detected compared with T2-weighted images alone (eight external iliac, 24 inguinal, 12 obturator, two peri-rectal, one presacral). Nodes detected only on fusion images were 2-9 mm (mean 3.7 mm). Nodal visualisation was better using fusion images compared with T2-weighted images (mean RIDIT score 0.689 vs 0.302). Fusion of diffusion-weighted MR with T2-weighted images improves identification of pelvic lymph nodes compared with T2-weighted images alone. The improved nodal identification may aid treatment planning and further nodal characterisation.

  3. MR urography (MRU of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR

    Directory of Open Access Journals (Sweden)

    C. Roy

    2014-01-01

    Conclusion: T2-weighted MRU with multiple orientations and diuretic is sufficient to identify the non-dilated ureter. It offers information on ureteral peristaltism. It can be suggested that this sequence is able to detect an initial obstruction before hydronephrosis occurs.

  4. Composite Dark Sectors

    International Nuclear Information System (INIS)

    Carmona, Adrian

    2015-06-01

    We introduce a new paradigm in Composite Dark Sectors, where the full Standard Model (including the Higgs boson) is extended with a strongly-interacting composite sector with global symmetry group G spontaneously broken to H is contained in G. We show that, under well-motivated conditions, the lightest neutral pseudo Nambu-Goldstone bosons are natural dark matter candidates for they are protected by a parity symmetry not even broken in the electroweak phase. These models are characterized by only two free parameters, namely the typical coupling g D and the scale f D of the composite sector, and are therefore very predictive. We consider in detail two minimal scenarios, SU(3)/[SU(2) x U(1)] and [SU(2) 2 x U(1)]/[SU(2) x U(1)], which provide a dynamical realization of the Inert Doublet and Triplet models, respectively. We show that the radiatively-induced potential can be computed in a five-dimensional description with modified boundary conditions with respect to Composite Higgs models. Finally, the dark matter candidates are shown to be compatible, in a large region of the parameter space, with current bounds from dark matter searches as well as electroweak and collider constraints on new resonances.

  5. Evaluation of renal function with dynamic MRI-T2-weighted gradient echo technique

    International Nuclear Information System (INIS)

    Kato, Katsuya

    1995-01-01

    To evaluate the usefulness of dynamic MRI of kidneys in healthy volunteers and patients with different 24-hour creatinine clearance (Ccr) levels, a dynamic study that employed the T2 weighted gradient echo technique (FLASH: TR/TE=34/25 msec, flip angle= 20 degrees) with single images during breathhold was performed on 10 healthy volunteers and 35 patients, all examined for the Ccr and suspected of having renal parenchymal disease after a phantom study. T1-weighted and dynamic MR imagings were obtained with a 1.5T imager. I analyzed the time-intensity curve of renal cortex and medulla, and defined a cortex decreased ratio (CDR) and medulla decreased ratio (MDR) in comparison with the Ccr. The cortico-medullary difference ratio (CMDR) of T1WI was also compared with the Ccr. The parameters of the T2 dynamic MRI study (CDR, MDR) better correlated with the Ccr than CMDR. Renal function can be quantitatively evaluated with the T2 dynamic MRI and there is a possibility that we can qualitatively evaluate the renal dysfunction and estimate its cause. (author)

  6. Expression of the sFLT1 gene in cord blood cells is associated to maternal arsenic exposure and decreased birth weight.

    Directory of Open Access Journals (Sweden)

    Sylvie Remy

    Full Text Available There is increasing epidemiologic evidence that arsenic exposure in utero is associated with adverse pregnancy outcomes and may contribute to long-term health effects. These effects may occur at low environmental exposures but the underlying molecular mechanism is not clear. We collected cord blood samples of 183 newborns to identify associations between arsenic levels and birth anthropometric parameters in an area with very low arsenic exposure. Our core research aim was to screen for transcriptional marks that mechanistically explain these associations. Multiple regression analyses showed that birth weight decreased with 47 g (95% CI: 16-78 g for an interquartile range increase of 0.99 μg/L arsenic. The model was adjusted for child's sex, maternal smoking during pregnancy, gestational age, and parity. Higher arsenic concentrations and reduced birth weight were positively associated with changes in expression of the sFLT1 (soluble fms-like tyrosine kinase-1 gene in cord blood cells in girls. The protein product of sFLT1 is a scavenger of vascular endothelial growth factor (VEGF in the extracellular environment and plays a key role in the inhibition of placental angiogenesis. In terms of fetal development, inhibition of placental angiogenesis leads to impaired nutrition and hence to growth retardation. Various genes related to DNA methylation and oxidative stress showed also changed expression in relation to arsenic exposure but were not related to birth outcome parameters. In conclusion, this study suggests that increased expression of sFLT1 is an intermediate marker that points to placental angiogenesis as a pathway linking prenatal arsenic exposure to reduced birth weight.

  7. Brain MR imaging in patients with hepatic cirrhosis: relationship between high intensity signal in basal ganglia on T1-weighted images and elemental concentrations in brain

    International Nuclear Information System (INIS)

    Maeda, H.; Sato, M.; Yoshikawa, A.; Kimura, M.; Sonomura, T.; Terada, M.; Kishi, K.

    1997-01-01

    In patients with hepatic cirrhosis, the globus pallidus and putamen show high intensity on T1-weighted MRI. While the causes of this high signal have been thought to include paramagnetic substances, especially manganese, no evidence for this has been presented. Autopsy in four cases of hepatic cirrhosis permitted measurement of metal concentrations in brain and histopathological examination. In three cases the globus pallidus showed high intensity on T1-weighted images. Mean manganese concentrations in globus pallidus, putamen and frontal white matter were 3.03 ± 0.38, 2.12 ± 0.37, and 1.38 ± 0.24 (μg/g wet weight), respectively, being approximately four- to almost ten-fold the normal values. Copper concentrations in globus pallidus and putamen were also high, 50 % more than normal. Calcium, iron, zinc and magnesium concentrations were all normal. The fourth case showed no abnormal intensity in the basal ganglia and brain metal concentrations were all normal. Histopathologically, cases with showing high signal remarkable atrophy, necrosis, and deciduation of nerve cells and proliferation of glial cells and microglia in globus pallidus. These findings were similar to those in chronic manganese poisoning. On T1-weighted images, copper deposition shows no abnormal intensity. It is therefore inferred that deposition of highly concentrations of manganese may caused high signal on T1-weighted images and nerve cell death in the globus pallidus. (orig.). With 2 figs., 2 tabs

  8. Hyperintensity of basal ganglia on T1-weighted images in patients with liver cirrhosis. Correlation with hepatic encephalopathy and liver function

    International Nuclear Information System (INIS)

    Maeda, Hiroko; Kita, Keisuke; Mizobata, Toshiharu; Kimura, Masashi; Sonomura, Tetsuo; Kishi, Kazushi; Tanaka, Kayo; Sato, Morio; Yamada, Ryosaku

    1995-01-01

    Brain MR imaging was performed in 38 liver cirrhosis (LC) patients and 9 normal volunteers. On T 1 -weighted images, the signal intensity of globus pallidus (S1) and frontal white matter (S2) was measured and S1/S2 ratio was explored. We examined the relationship between S1/S2 ratio and liver function parameters. High signal intensity in bilateral globus pallidus was noted on T 1 W1 in 28 of 38 LC patients. The S1/S2 ratio of 1.186±0.097 in the 38 LC patients was significantly higher than 0.987±0.062 in the 9 normal volunteers (p 2 -weighted images showed no abnormal intensity. Compared with the LC patients with hepatic encephalopathy (HE) (n=7) and without HE (n=31), the former S1/S2 ratio (1.239±0.057) was significantly higher than the latter (1.174±0.097) (p 15 (r=0.501, p 1 -WI and the degree of liver dysfunction. (author)

  9. The C*-algebras of quantum lens and weighted projective spaces

    DEFF Research Database (Denmark)

    Brzezinski, Tomasz; Szymanski, Wojciech

    2018-01-01

    It is shown that the algebra of continuous functions on the quantum 2n+1-dimensional lens space C(L^{2n+1}_q(N; m_0,..., m_n)) is a graph C*-algebra, for arbitrary positive weights m_0,..., m_n. The form of the corresponding graph is determined from the skew product of the graph which defines the...

  10. Fat-suppressed T2-weighted MRI appearance of subchondral insufficiency fracture of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Kazuhiko; Yamamoto, Takuaki; Motomura, Goro; Karasuyama, Kazuyuki; Kubo, Yusuke; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan)

    2016-11-15

    Our aims were to investigate the imaging appearance of subchondral insufficiency fracture (SIF) of the femoral head based on fat-suppressed T2-weighted MRI, and evaluate its correlation with the clinical outcomes following conservative treatment. We retrospectively evaluated 40 hips in 37 patients with SIF of the femoral head (12 males and 25 females; mean age 55.8 years, range 22-78 years). MRI examinations were performed within 3 months after the onset of hip pain. Using fat-suppressed T2-weighted imaging, we evaluated the hips for the intensity of the subchondral bone (corresponding to the area superior to the low intensity band on T1-weighted images) as well as bone marrow edema, joint effusion, and presence of the band lesion. We then correlated the intensity of the subchondral bone with clinical outcomes. The hips were classified into three types based on subchondral intensity on fat-suppressed T2-weighted images: type 1 (21 hips) showed high intensity, type 2 (eight hips) showed heterogeneous intensity, and type 3 (11 hips) showed low intensity. The mean period between pain onset and MRI examination was significantly longer for type 2 hips than for type 1. Healing rates were 86 % for type 1, 75 % for type 2, and 18 % for type 3. SIF cases were classified into three types based on subchondral intensity on fat-suppressed T2-weighted imaging performed within 3 months after pain onset. Type 3 SIF tended to be intractable to conservative treatment compared to type 1 and type 2. (orig.)

  11. Interleukin-1β (IL-1β) increases pain behavior and the blood glucose level: possible involvement of sympathetic nervous system.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kang, Yu-Jung; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Suh, Hong-Won

    2012-07-01

    The relationship between interleukin-1β (IL-1β)-induced nociception and the blood glucose level was studied in ICR mice. We found in the present study that intrathecal (i.t.) injection of IL-1β increased pain behavior. In addition, i.t. IL-1β injection caused an elevation of the blood glucose level. The time-course study showed that maximal blood glucose level was observed 30 and 60 min after i.t. IL-1β administration. Furthermore, i.t. injection of IL-1β enhanced the blood glucose level when mice were orally fed with d-glucose. The i.t. administration of IL-1β antagonist (AF12198) inhibited the hyperglycemia and pain behaviors induced by IL-1β. We found in the present study that adrenal tyrosine hydroxylase (TH) mRNA level was also increased by i.t. IL-1β injection. Furthermore, intraperitoneal (i.p.) pretreatment with phentolamine (an α(1)-adrenergic blocker) or yohimbine (an α(2)-adrenergic blocker) significantly attenuated the blood glucose level and pain behavior induced by IL-1β administered i.t. However, the blood glucose level and pain behavior were not affected by butoxamine (a β(2)-adrenergic blocker), whereas metoprolol (a β(2)-adrenergic blocker) enhanced IL-1β-induced blood glucose level and pain behavior in mice fed with d-glucose. However, its effect was not statistically significant. Our results suggest that IL-1β administered i.t. increases the blood glucose level via an activation of α adrenergic nervous system. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Particle Dark Matter (1/4)

    CERN Multimedia

    CERN. Geneva

    2011-01-01

    I review the phenomenology of particle dark matter, including the process of thermal freeze-out in the early universe, and the direct and indirect detection of WIMPs. I also describe some of the most popular particle candidates for dark matter and summarize the current status of the quest to discover dark matter's particle identity.

  13. Gauge coupling unification and nonequilibrium thermal dark matter.

    Science.gov (United States)

    Mambrini, Yann; Olive, Keith A; Quevillon, Jérémie; Zaldívar, Bryan

    2013-06-14

    We study a new mechanism for the production of dark matter in the Universe which does not rely on thermal equilibrium. Dark matter is populated from the thermal bath subsequent to inflationary reheating via a massive mediator whose mass is above the reheating scale T(RH). To this end, we consider models with an extra U(1) gauge symmetry broken at some intermediate scale (M(int) ≃ 10(10)-10(12) GeV). We show that not only does the model allow for gauge coupling unification (at a higher scale associated with grand unification) but it can provide a dark matter candidate which is a standard model singlet but charged under the extra U(1). The intermediate scale gauge boson(s) which are predicted in several E6/SO(10) constructions can be a natural mediator between dark matter and the thermal bath. We show that the dark matter abundance, while never having achieved thermal equilibrium, is fixed shortly after the reheating epoch by the relation T(RH)(3)/M(int)(4). As a consequence, we show that the unification of gauge couplings which determines M(int) also fixes the reheating temperature, which can be as high as T(RH) ≃ 10(11) GeV.

  14. Abdominal MRI at 3.0 T: LAVA-Flex compared with conventional fat suppression T1-weighted images.

    Science.gov (United States)

    Li, Xing Hui; Zhu, Jiang; Zhang, Xiao Ming; Ji, Yi Fan; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Zeng, Nan Lin

    2014-07-01

    To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver. © 2013 Wiley Periodicals, Inc.

  15. A general model to calculate the spin-lattice (T1) relaxation time of blood, accounting for haematocrit, oxygen saturation and magnetic field strength.

    Science.gov (United States)

    Hales, Patrick W; Kirkham, Fenella J; Clark, Christopher A

    2016-02-01

    Many MRI techniques require prior knowledge of the T1-relaxation time of blood (T1bl). An assumed/fixed value is often used; however, T1bl is sensitive to magnetic field (B0), haematocrit (Hct), and oxygen saturation (Y). We aimed to combine data from previous in vitro measurements into a mathematical model, to estimate T1bl as a function of B0, Hct, and Y. The model was shown to predict T1bl from in vivo studies with a good accuracy (± 87 ms). This model allows for improved estimation of T1bl between 1.5-7.0 T while accounting for variations in Hct and Y, leading to improved accuracy of MRI-derived perfusion measurements. © The Author(s) 2015.

  16. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar [SGRR Institute of Medical and Health Sciences, Patel Nagar, Dehradun (India)

    2017-11-15

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol.

  17. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    International Nuclear Information System (INIS)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar

    2017-01-01

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol

  18. [Correlation analysis of the pre-pregnant body mass index, the gestational weight gain and umbilical cord blood C peptide].

    Science.gov (United States)

    Chen, X L; Han, Y; Zhao, X M; Liu, Y; Lü, J J

    2017-01-03

    Objective: To explore the correlation among the pre-pregnant body mass index (BMI), gestational weight gain (GWG) and umbilical cord blood C peptide, and to investigate the influence of maternal weight management on the incidence of baby long-term metabolic syndrome. Methods: During May to Aug.2015, 485 pregnant women in Zhejiang Taizhou first people's hospital and Taizhou Huangyan maternal &child care service centre were selected in random and divided into four groups according to pre-pregnant BMI: low body mass, normal body mass, over body mass and obese group, and also divided into two groups for getting gestational diabetes mellitus (GDM) or not. According to the gestational weight gain (GWG), all the cases were divided into two groups: above the Institute Of Medicine (IMO) 2009 recommendations or not. According to the outcome, the GDM group which had received weight control treatment, was divided into successful treat group or not. At last, we tested the umbilical cord blood C peptide and birth weight of each newborn and compared the difference in all subgroups. The correlation between the umbilical cord blood C peptide and birth weight were analysed. Results: (1) In the pre-pregnant BMI groups, there were significant differences of incidence of GDM ( P 0.05). (2) Newborn birth weight and the umbilical cord blood C peptide were positively correlated ( r =0.673, P newborn birth weight in all subgroups. (4) All groups showed correlations with neonatal umbilical cord blood C peptide, the GDM mostly (β=0.58), pre-pregnant BMI secondly (β: 0.36, 0.38) , and GWG weakly (β=0.17). (5) By stratification analysis, in GDM group, low body mass was negatively correlated with umbilical cord blood C peptide ( P gestational weight gain and umbilical cord blood C peptide. Suitable maternal weight control especially pre-pregnant body mass index control will lower the baby long-term metabolic syndrome incidence.

  19. Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

    Science.gov (United States)

    Brown, Ryan; Storey, Pippa; Geppert, Christian; McGorty, KellyAnne; Leite, Ana Paula Klautau; Babb, James; Sodickson, Daniel K; Wiggins, Graham C; Moy, Linda

    2013-11-01

    To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T and to compare 7-T and 3-T images. Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and 3D gradient echo sequence with adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. Image scores at 7 and 3 T were similar on standard-resolution images (1.1 × 1.1 × 1.1-1.6 mm(3)), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P ≤ 0.0001). Fibroglandular/fat contrast was more than two times higher at 7 T than at 3 T, owing to effective adiabatic inversion-based FS and the inherent 7-T signal advantage. Signal uniformity was comparable at 7 and 3 T (P coil and adiabatic inversion-based FS technique produce image quality that is as good as or better than at 3 T. • High image quality bilateral breast MRI is achievable with clinical parameters at 7 T. • 7-T high-resolution imaging improves delineation of subtle soft tissue structures. • Adiabatic-based fat suppression provides excellent fibroglandular/fat contrast at 7 T. • 7- and 3-T 3D T1-weighted gradient-echo images have similar signal uniformity. • The 7-T dual solenoid coil enables bilateral imaging without compromising uniformity.

  20. Characterization of associate spaces of generalized weighted weak-Lorentz spaces and embeddings

    Czech Academy of Sciences Publication Activity Database

    Gogatishvili, Amiran; Aykol, C.; Guliyev, V.S.

    2015-01-01

    Roč. 228, č. 3 (2015), s. 223-233 ISSN 0039-3223 R&D Projects: GA ČR GA13-14743S Institutional support: RVO:67985840 Keywords : generalized weighted weak-Lorentz spaces * reverse Hardy inequalities * associate spaces * embeddings Subject RIV: BA - General Mathematics Impact factor: 0.623, year: 2015 http://journals.impan.gov.pl/sm/Inf/228-3-2.html

  1. Therapeutic potential of umbilical cord blood cells for type 1 diabetes mellitus.

    Science.gov (United States)

    He, Binbin; Li, Xia; Yu, Haibo; Zhou, Zhiguang

    2015-11-01

    Type 1 diabetes mellitus (T1DM) is a chronic disorder that results from autoimmune-mediated destruction of pancreatic islet β-cells. However, to date, no conventional intervention has successfully treated the disease. The optimal therapeutic method for T1DM should effectively control the autoimmunity, restore immune homeostasis, preserve residual β-cells, reverse β-cell destruction, and protect the regenerated insulin-producing cells against re-attack. Umbilical cord blood is rich in regulatory T (T(reg)) cells and multiple types of stem cells that exhibit immunomodulating potential and hold promise in their ability to restore peripheral tolerance towards pancreatic islet β-cells through remodeling of immune responses and suppression of autoreactive T cells. Recently, reinfusion of autologous umbilical cord blood or immune cells from cord blood has been proposed as a novel therapy for T1DM, with the advantages of no risk to the donors, minimal ethical concerns, a low incidence of graft-versus-host disease and easy accessibility. In this review, we revisit the role of autologous umbilical cord blood or immune cells from cord blood-based applications for the treatment of T1DM. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  2. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    Science.gov (United States)

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of gadolinium deposition requires tissue analysis. Any potential clinical sequelae of gadolinium retention in

  3. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  4. High signal in the spinal cord on T2-weighted images in rapidly progressive tropical spastic paraparesis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Hara, A.; Murakami, T.; Ando, Y.; Uyama, E.; Mita, S.; Uchino, M. [Kumamoto Univ. (Japan). School of Medicine; Yamashita, T. [Kumamoto Univ. (Japan). School of Medicine; Dept. of Neurology, Kumamoto Univ. (Japan)

    2001-03-01

    We report a 59-year-old woman with human T-cell lymphotrophic virus type-I (HTLV-I) associated myelopathy/tropical spastic paraparesis who showed high signal in the cervical and thoracic spinal cord on T2-weighted and contrast enhancement on T1-weighted images. (orig.)

  5. Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

    Science.gov (United States)

    Nutman, A; Fisher Even-Tsur, S; Shapiro, G; Braun, T; Schwartz, D; Carmeli, Y

    2016-09-01

    Rapid identification of the causative pathogen in patients with bacteremia allows adjustment of antibiotic therapy and improves patient outcomes. We compared in vitro and real-life time to detection (TTD) of two blood culture media, BacT/Alert FA (FA) and BacT/Alert FA Plus (FA Plus), for the nine most common species of bacterial pathogens recovered from blood samples. Experimental data from simulated cultures was compared with microbiology records of TTD for both culture media with growth of the species of interest in clinical blood cultures. In the experimental conditions, median TTD was 3.8 hours (23.9 %) shorter using FA Plus media. The magnitude of reduction differed between species. Similarly, in real life data, FA Plus had shorter TTD than FA media; however, the difference between culture media was smaller, and median TTD was only 1 hour (8.5 %) less. We found shorter TTD with BacT/Alert FA Plus culture media, both experimentally and in real-life conditions and unrelated to antibiotic neutralization, highlighting the importance of appropriate blood culture media selection.

  6. Histogram Profiling of Postcontrast T1-Weighted MRI Gives Valuable Insights into Tumor Biology and Enables Prediction of Growth Kinetics and Prognosis in Meningiomas.

    Science.gov (United States)

    Gihr, Georg Alexander; Horvath-Rizea, Diana; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Henkes, Hans; Richter, Cindy; Hoffmann, Karl-Titus; Surov, Alexey; Schob, Stefan

    2018-06-14

    Meningiomas are the most frequently diagnosed intracranial masses, oftentimes requiring surgery. Especially procedure-related morbidity can be substantial, particularly in elderly patients. Hence, reliable imaging modalities enabling pretherapeutic prediction of tumor grade, growth kinetic, realistic prognosis, and-as a consequence-necessity of surgery are of great value. In this context, a promising diagnostic approach is advanced analysis of magnetic resonance imaging data. Therefore, our study investigated whether histogram profiling of routinely acquired postcontrast T1-weighted images is capable of separating low-grade from high-grade lesions and whether histogram parameters reflect Ki-67 expression in meningiomas. Pretreatment T1-weighted postcontrast volumes of 44 meningioma patients were used for signal intensity histogram profiling. WHO grade, tumor volume, and Ki-67 expression were evaluated. Comparative and correlative statistics investigating the association between histogram profile parameters and neuropathology were performed. None of the investigated histogram parameters revealed significant differences between low-grade and high-grade meningiomas. However, significant correlations were identified between Ki-67 and the histogram parameters skewness and entropy as well as between entropy and tumor volume. Contrary to previously reported findings, pretherapeutic postcontrast T1-weighted images can be used to predict growth kinetics in meningiomas if whole tumor histogram analysis is employed. However, no differences between distinct WHO grades were identifiable in out cohort. As a consequence, histogram analysis of postcontrast T1-weighted images is a promising approach to obtain quantitative in vivo biomarkers reflecting the proliferative potential in meningiomas. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Condensate cosmology: Dark energy from dark matter

    International Nuclear Information System (INIS)

    Bassett, Bruce A.; Parkinson, David; Kunz, Martin; Ungarelli, Carlo

    2003-01-01

    Imagine a scenario in which the dark energy forms via the condensation of dark matter at some low redshift. The Compton wavelength therefore changes from small to very large at the transition, unlike quintessence or metamorphosis. We study cosmic microwave background (CMB), large scale structure, supernova and radio galaxy constraints on condensation by performing a four parameter likelihood analysis over the Hubble constant and the three parameters associated with Q, the condensate field: Ω Q , w f and z t (energy density and equation of state today, and redshift of transition). Condensation roughly interpolates between ΛCDM (for large z t ) and SCDM (low z t ) and provides a slightly better fit to the data than ΛCDM. We confirm that there is no degeneracy in the CMB between H and z t and discuss the implications of late-time transitions for the Lyman-α forest. Finally we discuss the nonlinear phase of both condensation and metamorphosis, which is much more interesting than in standard quintessence models

  8. Evolution of compact stars and dark dynamical variables

    Energy Technology Data Exchange (ETDEWEB)

    Bhatti, M.Z.; Yousaf, Z. [University of the Punjab, Department of Mathematics, Lahore (Pakistan); Ilyas, M. [University of the Punjab, Centre for High Energy Physics, Lahore (Pakistan)

    2017-10-15

    This work aims to explore the dark dynamical effects of the f(R, T) modified gravity theory on the dynamics of a compact celestial star. We have taken the interior geometry of a spherical star which is filled with an imperfect fluid distribution. The modified field equations are explored by taking a particular form of the f(R, T) model, i.e. f(R, T) = f{sub 1}(R) + f{sub 2}(R)f{sub 3}(T). These equations are utilized to formulate the well-known structure scalars under the dark dynamical effects of this higher-order gravity theory. Also, with the help of these scalar variables, the evolution equations for expansion and shear are formulated. The whole analysis is made under the condition of a constant R and T. We found a crucial significance of dark source terms and dynamical variables on the evolution and density inhomogeneity of compact objects. (orig.)

  9. Endoscopic extraperitoneal radical prostatectomy after radical resection of pT1-pT2 rectal cancer: a report of thirty cases.

    Science.gov (United States)

    Liu, Zhuo; Li, Dechuan; Chen, Yinbo

    2017-01-01

    Endoscopic extraperitoneal radical prostatectomy (EERPE) has gained popularity for the treatment of localized prostate cancer. However, prior complex lower abdominal or pelvic surgery can complicate subsequent EERPE. To date, there have been few reports on patients who underwent EERPE after radical resection of pT1-pT2 rectal cancer. To present our experience with EERPE in patients after radical resection of pT1-pT2 rectal carcinoma and introduce a simple and effective way to create an extraperitoneal working space. Thirty patients after radical resection of pT1-pT2 rectal carcinoma were treated with EERPE for biopsy-proven localized prostate cancer. Operation time, estimated blood loss, conversion to open surgery rate, transfusion rate and transurethral catheter time were recorded. Meanwhile, functional outcome (continence and potency) and oncological outcome were reviewed. The average operative time was 168 min. Mean blood loss was 195 ml. There was no need for conversion to open surgery or transfusion. The catheter was removed on postoperative day (POD) 7.8. After a mean follow-up time of 53.1 months, 3 patients had a prostate-specific antigen level relapse over 0.1 ng/ml. At the follow-up time, 26 patients were completely continent, and 4 needed 1-2 pads/day. Of the 6 patients who underwent neurovascular bundle preservation, none have experienced return of erections at the last follow-up time. Endoscopic extraperitoneal radical prostatectomy after radical resection of rectal carcinoma appears promising, with feasibility in experienced hands. The operative data, postoperative urinary incontinence and oncological outcomes appear encouraging, but the rate of erectile dysfunction seems to be disappointing.

  10. Dark-matter decay as a complementary probe of multicomponent dark sectors.

    Science.gov (United States)

    Dienes, Keith R; Kumar, Jason; Thomas, Brooks; Yaylali, David

    2015-02-06

    In single-component theories of dark matter, the 2→2 amplitudes for dark-matter production, annihilation, and scattering can be related to each other through various crossing symmetries. The detection techniques based on these processes are thus complementary. However, multicomponent theories exhibit an additional direction for dark-matter complementarity: the possibility of dark-matter decay from heavier to lighter components. We discuss how this new detection channel may be correlated with the others, and demonstrate that the enhanced complementarity which emerges can be an important ingredient in probing and constraining the parameter spaces of such models.

  11. Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schubert, Tilman B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Basel University Hospital, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Said, Adnan [University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); Mezrich, Joshua D. [University of Wisconsin-Madison, Department of Surgery, Madison, WI (United States); Reeder, Scott B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin-Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin-Madison, Department of Emergency Medicine, Madison, WI (United States)

    2017-10-15

    Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC). Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography (PTC) were analysed. Two readers reviewed the MRCs and rated image quality (IQ) and likelihood for AS/NAS/BC on Likert scales. Sensitivity, specificity and predictive values were calculated, ROC curve analysis performed, and inter-reader variability assessed. The subjective added value of T1w-MRC was rated. IQ was high for all sequences without significant differences (2.83-2.88). In 39 patients ERCP/PTC detected a complication. Sensitivity and specificity for AS were 64-96 using T2w-MRCP, increasing to 79-100 using all sequences. Use of all sequences increased the sensitivity of detecting NAS/BC from 72-92% to 88-100% and 67-89% to 72-94%, respectively. Kappa values were substantial (0.45-0.62). T1w-MRC was found to be helpful in 75-83.3%. Combining T1w-MRC and T2w-MRCP increased sensitivity and specificity and diagnostic confidence in patients after LT with suspected biliary complications. T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. (orig.)

  12. Dark Matter

    Indian Academy of Sciences (India)

    What You See Ain't What. You Got, Resonance, Vol.4,. No.9,1999. Dark Matter. 2. Dark Matter in the Universe. Bikram Phookun and Biman Nath. In Part 11 of this article we learnt that there are compelling evidences from dynamics of spiral galaxies, like our own, that there must be non-luminous matter in them. In this.

  13. T2-weighted fast spin-echo MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Francis, I.R.; Steiner, R.M.; Herfkens, R.J.; Jain, K.; Glover, G.H.

    1991-01-01

    A fast Se (FSE) sequence capable of acquiring SE images with a wide range of TRs and TEs in short imaging times has been recently introduced. I this paper, the authors evaluated the value of this technique compared with standard T2-weighted SE imaging. Twenty-five patients were evaluated with T2-weighted SE and FSE images on a 1.5-T GE Signa imager. Imaging times ranged from 3 to 5 minutes for the FSE acquisition and from 12 to 15 minutes for the SE images. Three observers performed a comparison by using a 10-point scale for organ definition and lesion conspicuity, with differences settled by consensus reading. Pelvic organ definition was superior and pelvic tumors and free fluid were also more conspicuous on FSE images. In 2/25 patients ringing artifacts were present

  14. Particle Physics Foundations of Dark Matter, Dark Energy, and Inflation (1/3)

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    Ninety-five percent of the present mass-energy density of the Universe is dark. Twenty-five percent is in the form of dark matter holding together galaxies and other large scale structures, and 70% is in the form of dark energy driving an accelerated expansion of the universe. Dark matter and dark energy cannot be explained within the standard model of particle physics. In the first lecture I will review the evidence for dark matter and the observations that point to an explanation in the form of cold dark matter. I will then describe the expected properties of a hypothetical Weakly-Interacting Massive Particle, or WIMP, and review experimental and observational approaches to test the hypothesis. Finally, I will discuss how the LHC might shed light on the problem. In the second lecture I will review the theoretical foundations and observational evidence that the dominant component of the present mass density of the Universe has a negative pressure, which leads to an accelerated expansion of the Universe...

  15. Unbounded weighted composition operators in L²-spaces

    CERN Document Server

    Budzyński, Piotr; Jung, Il Bong; Stochel, Jan

    2018-01-01

    This book establishes the foundations of the theory of bounded and unbounded weighted composition operators in L²-spaces. It develops the theory in full generality, meaning that the weighted composition operators under consideration are not regarded as products of multiplication and composition operators. A variety of seminormality properties are characterized and the first-ever criteria for subnormality of unbounded weighted composition operators is provided. The subtle interplay between the classical moment problem, graph theory and the injectivity problem is revealed and there is an investigation of the relationships between weighted composition operators and the corresponding multiplication and composition operators. The optimality of the obtained results is illustrated by a variety of examples, including those of discrete and continuous types. The book is primarily aimed at researchers in single or multivariable operator theory.

  16. Existence of Solutions for Degenerate Elliptic Problems in Weighted Sobolev Space

    Directory of Open Access Journals (Sweden)

    Lili Dai

    2015-01-01

    Full Text Available This paper is devoted to the study of the existence of solutions to a general elliptic problem Au+g(x,u,∇u=f-div⁡F, with f∈L1(Ω and F∈∏i=1NLp'(Ω,ωi*, where A is a Leray-Lions operator from a weighted Sobolev space into its dual and g(x,s,ξ is a nonlinear term satisfying gx,s,ξsgn⁡(s≥ρ∑i=1Nωi|ξi|p, |s|≥h>0, and a growth condition with respect to ξ. Here, ωi, ωi* are weight functions that will be defined in the Preliminaries.

  17. Weighted inequalities for fractional integral operators and linear commutators in the Morrey-type spaces

    Directory of Open Access Journals (Sweden)

    Hua Wang

    2017-01-01

    Full Text Available Abstract In this paper, we first introduce some new Morrey-type spaces containing generalized Morrey space and weighted Morrey space with two weights as special cases. Then we give the weighted strong type and weak type estimates for fractional integral operators I α $I_{\\alpha}$ in these new Morrey-type spaces. Furthermore, the weighted strong type estimate and endpoint estimate of linear commutators [ b , I α ] $[b,I_{\\alpha}]$ formed by b and I α $I_{\\alpha}$ are established. Also we study related problems about two-weight, weak type inequalities for I α $I_{\\alpha}$ and [ b , I α ] $[b,I_{\\alpha}]$ in the Morrey-type spaces and give partial results.

  18. Gadolinium-enhanced MR imaging of normal renal transplants. An evaluation of a T1-weighted dynamic echo-planar sequence

    International Nuclear Information System (INIS)

    Dupas, B.; Blancho, G.; Havet, T.; Leaute, F.

    1999-01-01

    Purpose: To evaluate the potential usefulness of dynamic MR with echoplanar imaging (EPI) in assessing the renal function in patients with renal allografts. Material and methods: Using a T1-weighted sequence, EPI was performed after injection of a Gd-chelate in 17 patients with normally functioning renal allografts. Time-intensity curves were plotted from the signal intensity (SI) measurements of the cortex and the medulla. Results: The pattern of corticomedullar differentiation (CMD) observed after constrast enhancement was divided into four phases using the T1-EPI. After a rapid decrease in the SI of cortical structures, and a subsequent return to precontrast levels, a gradual fall in the SI of the medulla was observed. The average time between the two periods of signal loss was 60 s. Conclusion: This study illustrated the potential use of dynamic T1-EPI to demonstrate contrast-induced CMD in renal allografts. (orig.)

  19. A 90-day dietary toxicity study of genetically modified rice T1C-1 expressing Cry1C protein in Sprague Dawley rats.

    Directory of Open Access Journals (Sweden)

    Xueming Tang

    Full Text Available In a 90-day study, Sprague Dawley rats were fed transgenic T1C-1 rice expressing Cry1C protein and were compared with rats fed non-transgenic parental rice Minghui 63 and rats fed a basal diet. No adverse effects on animal behavior or weight gain were observed during the study. Blood samples were collected and analyzed, and standard hematological and biochemical parameters were compared. A few of these parameters were found to be significantly different, but were within the normal reference intervals for rats of this breed and age, and were thus not considered to be treatment-related. Following sacrifice, a large number of organs were weighed, and macroscopic and histopathological examinations were performed with no changes reported. The aim of this study was to use a known animal model to determine the safety of the genetically modified (GM rice T1C-1. The results showed no adverse or toxic effects due to T1C-1 rice when tested in this 90-day study.

  20. A 90-day dietary toxicity study of genetically modified rice T1C-1 expressing Cry1C protein in Sprague Dawley rats.

    Science.gov (United States)

    Tang, Xueming; Han, Fangting; Zhao, Kai; Xu, Yan; Wu, Xiao; Wang, Jinbin; Jiang, Lingxi; Shi, Wei

    2012-01-01

    In a 90-day study, Sprague Dawley rats were fed transgenic T1C-1 rice expressing Cry1C protein and were compared with rats fed non-transgenic parental rice Minghui 63 and rats fed a basal diet. No adverse effects on animal behavior or weight gain were observed during the study. Blood samples were collected and analyzed, and standard hematological and biochemical parameters were compared. A few of these parameters were found to be significantly different, but were within the normal reference intervals for rats of this breed and age, and were thus not considered to be treatment-related. Following sacrifice, a large number of organs were weighed, and macroscopic and histopathological examinations were performed with no changes reported. The aim of this study was to use a known animal model to determine the safety of the genetically modified (GM) rice T1C-1. The results showed no adverse or toxic effects due to T1C-1 rice when tested in this 90-day study.

  1. Update on hidden sectors with dark forces and dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Andreas, Sarah

    2012-11-15

    Recently there has been much interest in hidden sectors, especially in the context of dark matter and ''dark forces'', since they are a common feature of beyond standard model scenarios like string theory and SUSY and additionally exhibit interesting phenomenological aspects. Various laboratory experiments place limits on the so-called hidden photon and continuously further probe and constrain the parameter space; an updated overview is presented here. Furthermore, for several hidden sector models with light dark matter we study the viability with respect to the relic abundance and direct detection experiments.

  2. WISPy cold dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Arias, Paola [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Cadamuro, Davide; Redondo, Javier [Max-Planck-Institut fuer Physik, Muenchen (Germany); Goodsell, Mark [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Jaeckel, Joerg [Durham Univ. (United Kingdom). Inst. for Particle Physics Phenomenology; Ringwald, Andreas [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2012-01-15

    Very weakly interacting slim particles (WISPs), such as axion-like particles (ALPs) or hidden photons (HPs), may be non-thermally produced via the misalignment mechanism in the early universe and survive as a cold dark matter population until today. We find that, both for ALPs and HPs whose dominant interactions with the standard model arise from couplings to photons, a huge region in the parameter spaces spanned by photon coupling and ALP or HP mass can give rise to the observed cold dark matter. Remarkably, a large region of this parameter space coincides with that predicted in well motivated models of fundamental physics. A wide range of experimental searches - exploiting haloscopes (direct dark matter searches exploiting microwave cavities), helioscopes (searches for solar ALPs or HPs), or light-shining-through-a-wall techniques - can probe large parts of this parameter space in the foreseeable future. (orig.)

  3. Exterior domain problems and decomposition of tensor fields in weighted Sobolev spaces

    OpenAIRE

    Schwarz, Günter

    1996-01-01

    The Hodge decompOsition is a useful tool for tensor analysis on compact manifolds with boundary. This paper aims at generalising the decomposition to exterior domains G ⊂ IR n. Let L 2a Ω k(G) be the space weighted square integrable differential forms with weight function (1 + |χ|²)a, let d a be the weighted perturbation of the exterior derivative and δ a its adjoint. Then L 2a Ω k(G) splits into the orthogonal sum of the subspaces of the d a-exact forms with vanishi...

  4. Accuracy of magnetic resonance imaging in planning the osseous resection margins of bony tumours in the proximal femur: based on coronal T1-weighted versus STIR images

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Sarfraz; Stevenson, Jonathan; Mangham, Charles; Cribb, Gillian; Cool, Paul [Robert Jones and Agnes Hunt Orthopaedic Hospital, Department of Musculoskeletal Oncology, Oswestry, Shropshire (United Kingdom)

    2014-12-15

    Assessment of the extent of tumours using magnetic resonance imaging (MRI) is the basis for bone resection in limb-salvage surgery. We aimed to compare the accuracy of T1-weighted MRI and STIR sequences in measuring the extent of proximal femoral tumours, using the macroscopic specimens as the gold standard for comparison. We compared single coronal T1-weighted with STIR sequences in 34 proximal femoral tumours, using bivalved resected macroscopic tumours for comparison. After randomisation, four observers measured longitudinal osseous tumour extent using MRI and specimen photographs on two separate occasions, 3 weeks apart. There were 25 metastatic tumours, 8 chondrosarcomas and 1 myeloma. Eight patients presented with pathological fractures. The Pearson's correlation coefficient for comparison of T1 with macroscopic tumours was 0.91 (95 % confidence interval [CI]: 0.83 to 0.96) for all observers and 0.90 (95 % CI: 0.81 to 0.95) for STIR images. This difference was not statistically significant, and T1 and STIR sequence measurements had similar precision and accuracy. Bland-Altman plots showed T1-weighted imaging to be unbiased, whereas STIR sequences were biased and had systematic error. Moreover, STIR measurements overestimated tumour size by 6.4 mm (95 % CI: -26.9 to 39.7 mm) and 2 patients were outliers. T1 measurements were closer to the macroscopic measurements with a mean difference of 1.3 mm (95 % CI: -28.9 mm to 31.5 mm), with 3 patients falling outside of this. The variance was greater for STIR measurements. This difference between T1 and STIR measurements was statistically significant (p = 0.000003). The intra-observer reliability between separate measurements for MRI and specimen photographs achieved interclass correlation coefficients of 0.97, 0.96 and 0.95 (T1, STIR and macroscopic tumour respectively). T1 had greater interobserver correlation than for STIR and macroscopic tumour measurements (0.88 vs 0.85 and 0.85 respectively). These

  5. Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Hori, Masatoshi; Kim, Tonsok; Onishi, Hiromitsu; Nakamoto, Atsushi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imaoka, Izumi; Kagawa, Yuki; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osaka (Japan); Ueguchi, Takashi; Tatsumi, Mitsuaki [Osaka University Hospital, Department of Radiology, Osaka (Japan); Enomoto, Takayuki [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan); Niigata University School of Medicine, Department of Obstetrics and Gynecology, Niigata (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan)

    2013-08-15

    To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm{sup 2}) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW - observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE - observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. (orig.)

  6. Hyperintensity of basal ganglia on T{sub 1}-weighted images in patients with liver cirrhosis. Correlation with hepatic encephalopathy and liver function

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroko; Kita, Keisuke; Mizobata, Toshiharu; Kimura, Masashi; Sonomura, Tetsuo; Kishi, Kazushi; Tanaka, Kayo; Sato, Morio; Yamada, Ryosaku [Wakayama Medical Coll. (Japan)

    1995-04-01

    Brain MR imaging was performed in 38 liver cirrhosis (LC) patients and 9 normal volunteers. On T{sub 1}-weighted images, the signal intensity of globus pallidus (S1) and frontal white matter (S2) was measured and S1/S2 ratio was explored. We examined the relationship between S1/S2 ratio and liver function parameters. High signal intensity in bilateral globus pallidus was noted on T{sub 1} W1 in 28 of 38 LC patients. The S1/S2 ratio of 1.186{+-}0.097 in the 38 LC patients was significantly higher than 0.987{+-}0.062 in the 9 normal volunteers (p<0.001), while T{sub 2}-weighted images showed no abnormal intensity. Compared with the LC patients with hepatic encephalopathy (HE) (n=7) and without HE (n=31), the former S1/S2 ratio (1.239{+-}0.057) was significantly higher than the latter (1.174{+-}0.097) (p<0.05). There was a significant correlation between the value of the S1/S2 ratio and deterioration of ICG R{sub 15} (r=0.501, p<0.005), prolongation of prothrombine time (r=-0.392, p<0.05) and decrease of choline esterase (r=-0.336, p<0.05). There was, however, little correlation between the value of the S1/S2 ratio and ammonia and Fisher ratio. In conclusion, there is a significant relationship between high intensity of globus pallidus on T{sub 1}-WI and the degree of liver dysfunction. (author).

  7. Gravitational collapse of dark energy field configurations and supermassive black hole formation

    International Nuclear Information System (INIS)

    Jhalani, V.; Kharkwal, H.; Singh, A.

    2016-01-01

    Dark energy is the dominant component of the total energy density of our Universe. The primary interaction of dark energy with the rest of the Universe is gravitational. It is therefore important to understand the gravitational dynamics of dark energy. Since dark energy is a low-energy phenomenon from the perspective of particle physics and field theory, a fundamental approach based on fields in curved space should be sufficient to understand the current dynamics of dark energy. Here, we take a field theory approach to dark energy. We discuss the evolution equations for a generic dark energy field in curved space-time and then discuss the gravitational collapse for dark energy field configurations. We describe the 3 + 1 BSSN formalism to study the gravitational collapse of fields for any general potential for the fields and apply this formalism to models of dark energy motivated by particle physics considerations. We solve the resulting equations for the time evolution of field configurations and the dynamics of space-time. Our results show that gravitational collapse of dark energy field configurations occurs and must be considered in any complete picture of our Universe. We also demonstrate the black hole formation as a result of the gravitational collapse of the dark energy field configurations. The black holes produced by the collapse of dark energy fields are in the supermassive black hole category with the masses of these black holes being comparable to the masses of black holes at the centers of galaxies.

  8. Gravitational collapse of dark energy field configurations and supermassive black hole formation

    Energy Technology Data Exchange (ETDEWEB)

    Jhalani, V.; Kharkwal, H.; Singh, A., E-mail: anupamsingh.iitk@gmail.com [L. N. Mittal Institute of Information Technology, Physics Department (India)

    2016-11-15

    Dark energy is the dominant component of the total energy density of our Universe. The primary interaction of dark energy with the rest of the Universe is gravitational. It is therefore important to understand the gravitational dynamics of dark energy. Since dark energy is a low-energy phenomenon from the perspective of particle physics and field theory, a fundamental approach based on fields in curved space should be sufficient to understand the current dynamics of dark energy. Here, we take a field theory approach to dark energy. We discuss the evolution equations for a generic dark energy field in curved space-time and then discuss the gravitational collapse for dark energy field configurations. We describe the 3 + 1 BSSN formalism to study the gravitational collapse of fields for any general potential for the fields and apply this formalism to models of dark energy motivated by particle physics considerations. We solve the resulting equations for the time evolution of field configurations and the dynamics of space-time. Our results show that gravitational collapse of dark energy field configurations occurs and must be considered in any complete picture of our Universe. We also demonstrate the black hole formation as a result of the gravitational collapse of the dark energy field configurations. The black holes produced by the collapse of dark energy fields are in the supermassive black hole category with the masses of these black holes being comparable to the masses of black holes at the centers of galaxies.

  9. Association of lead concentration in colostrum, maternal and cord blood with newborn weight in polluted vs. non-polluted areas of Iran

    Directory of Open Access Journals (Sweden)

    Golmohammadi T.

    2007-10-01

    Full Text Available Background: Lead poisoning has proven to be one of the most important environmental health problems among developing countries with both direct and indirect effects on human life. Lead is known to cross the blood-brain barrier and placenta, and accumulates in soft and hard tissues. Lead can be excreted in urine, stool, milk, sweat, nails and saliva. During pregnancy and lactation, lead is released from bones into the blood along with Ca2+. The toxic effects of lead on various human tissues have been studied extensively, but few studies have addressed its impact on fetal development during pregnancy. Blood levels of lead are higher in people living in lead-polluted regions. It has been reported that Tehran (central and southern parts is the most problematic city in terms of lead poisoning.Methods: From 86 sets of mothers and newborns in a non-polluted area of rural Rasht, Iran, we examined specimens of maternal blood, cord blood and colostrum (86×3=258 and specimens from 85 sets of mothers and newborns in a polluted area of Tehran, Iran (85×3=255 for lead levels using atomic absorption spectrophotometry (AAS and analyzed the results by t-test, SPSS, and linear regression.Results: The mean blood lead concentrations of mothers, cord blood of newborns and colostrum were 7.6±4.1, 5.9±3 and 4.2±2.5 μg/dl, respectively, in the non-polluted area and 9.1±8.4, 6.5±5.2 and 5.8±5.5 μg/dl, respectively, in the polluted area. The mean weights of the newborns in non-polluted and polluted areas were 3.2±0.5 kg and 3.2±4.5 kg, respectively.Conclusions: Our data revealed an association between mean concentrations in blood lead of mothers and newborns and between mean concentrations of colostrum lead and newborn blood lead in both areas (p=0.01. There was no association between mean blood lead concentration of mothers with the weight of their newborns (p=0.89.

  10. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  11. Effect of ileo-rectal anastomosis and post-valve T-caecum cannulation on growing pigs : 2. Blood variables and mineral balances

    NARCIS (Netherlands)

    Köhler, T.; Verstegen, M.W.A.; Mosenthin, R.; Wensing, T.; Hartog, L.A. den; Huisman, J.

    1992-01-01

    In a long-term study nine ileo-rectally anastomosed (IRA) and seven post-valve T-caecum (PVTC)-cannulated pigs were compared with six intact pigs with regard to different blood variables, sodium and potassium retention and weights of selected organs. After surgery, apart from urea and K measured 13

  12. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U.; Grobholz, R.; Heilmann, M.; Michel, M.S.; Trojan, L.; Werner, A.; Rabe, J.; Schlemmer, H.P.

    2003-01-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k ep ).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k ep . Prostate carcinomas of the peripheral zone were demarcated by amplitude and k ep . In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k ep and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k ep reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [de

  13. New holographic dark energy model with constant bulk viscosity in modified f(R,T) gravity theory

    Science.gov (United States)

    Srivastava, Milan; Singh, C. P.

    2018-06-01

    The aim of this paper is to study new holographic dark energy (HDE) model in modified f(R,T) gravity theory within the framework of a flat Friedmann-Robertson-Walker model with bulk viscous matter content. It is thought that the negative pressure caused by the bulk viscosity can play the role of dark energy component, and drive the accelerating expansion of the universe. This is the motive of this paper to observe such phenomena with bulk viscosity. In the specific model f(R,T)=R+λ T, where R is the Ricci scalar, T the trace of the energy-momentum tensor and λ is a constant, we find the solution for non-viscous and viscous new HDE models. We analyze new HDE model with constant bulk viscosity, ζ =ζ 0= const. to explain the present accelerated expansion of the universe. We classify all possible scenarios (deceleration, acceleration and their transition) with possible positive and negative ranges of λ over the constraint on ζ 0 to analyze the evolution of the universe. We obtain the solutions of scale factor and deceleration parameter, and discuss the evolution of the universe. We observe the future finite-time singularities of type I and III at a finite time under certain constraints on λ . We also investigate the statefinder and Om diagnostics of the viscous new HDE model to discriminate with other existing dark energy models. In late time the viscous new HDE model approaches to Λ CDM model. We also discuss the thermodynamics and entropy of the model and find that it satisfies the second law of thermodynamics.

  14. Blood CXCR3+ CD4 T Cells Are Enriched in Inducible Replication Competent HIV in Aviremic Antiretroviral Therapy-Treated Individuals.

    Science.gov (United States)

    Banga, Riddhima; Procopio, Francesco A; Ruggiero, Alessandra; Noto, Alessandra; Ohmiti, Khalid; Cavassini, Matthias; Corpataux, Jean-Marc; Paxton, William A; Pollakis, Georgios; Perreau, Matthieu

    2018-01-01

    We recently demonstrated that lymph nodes (LNs) PD-1 + /T follicular helper (Tfh) cells from antiretroviral therapy (ART)-treated HIV-infected individuals were enriched in cells containing replication competent virus. However, the distribution of cells containing inducible replication competent virus has been only partially elucidated in blood memory CD4 T-cell populations including the Tfh cell counterpart circulating in blood (cTfh). In this context, we have investigated the distribution of (1) total HIV-infected cells and (2) cells containing replication competent and infectious virus within various blood and LN memory CD4 T-cell populations of conventional antiretroviral therapy (cART)-treated HIV-infected individuals. In the present study, we show that blood CXCR3-expressing memory CD4 T cells are enriched in cells containing inducible replication competent virus and contributed the most to the total pool of cells containing replication competent and infectious virus in blood. Interestingly, subsequent proviral sequence analysis did not indicate virus compartmentalization between blood and LN CD4 T-cell populations, suggesting dynamic interchanges between the two compartments. We then investigated whether the composition of blood HIV reservoir may reflect the polarization of LN CD4 T cells at the time of reservoir seeding and showed that LN PD-1 + CD4 T cells of viremic untreated HIV-infected individuals expressed significantly higher levels of CXCR3 as compared to CCR4 and/or CCR6, suggesting that blood CXCR3-expressing CD4 T cells may originate from LN PD-1 + CD4 T cells. Taken together, these results indicate that blood CXCR3-expressing CD4 T cells represent the major blood compartment containing inducible replication competent virus in treated aviremic HIV-infected individuals.

  15. Blood profiling of proteins and steroids during weight maintenance with manipulation of dietary protein level and glycaemic index

    DEFF Research Database (Denmark)

    Wang, Ping; Holst, Claus; Astrup, Arne

    2012-01-01

    ) blood biomarkers of dietary protein and GI levels during the weight-maintenance phase. Blood samples were collected at baseline, after 8 weeks of low-energy diet-induced weight loss and after a 6-month dietary intervention period from female continued weight losers (n 48) and weight regainers (n 48......), evenly selected from four dietary groups that varied in protein and GI levels. The blood concentrations of twenty-nine proteins and three steroid hormones were measured. The changes in analytes during weight maintenance largely correlated negatively with the changes during weight loss, with some...

  16. T2-weighted liver MRI using the multiVane technique at 3T: Comparison with conventional T2-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyung A [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyoung; Choi, Dong Il; Lee, Won Jae [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Philips, Seoul (Korea, Republic of); Jung, Sin Ho; Baek, Sun Young [Biostatistics and Clinical Epidemiology Center, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-10-15

    To assess the value of applying MultiVane to liver T2-weighted imaging (T2WI) compared with conventional T2WIs with emphasis on detection of focal liver lesions. Seventy-eight patients (43 men and 35 women) with 86 hepatic lesions and 20 pancreatico-biliary diseases underwent MRI including T2WIs acquired using breath-hold (BH), respiratory-triggered (RT), and MultiVane technique at 3T. Two reviewers evaluated each T2WI with respect to artefacts, organ sharpness, and conspicuity of intrahepatic vessels, hilar duct, and main lesion using five-point scales, and made pairwise comparisons between T2WI sequences for these categories. Diagnostic accuracy (Az) and sensitivity for hepatic lesion detection were evaluated using alternative free-response receiver operating characteristic analysis. MultiVane T2WI was significantly better than BH-T2WI or RT-T2WI for organ sharpness and conspicuity of intrahepatic vessels and main lesion in both separate reviews and pairwise comparisons (p < 0.001). With regard to motion artefacts, MultiVane T2WI or BH-T2WI was better than RT-T2WI (p < 0.001). Conspicuity of hilar duct was better with BH-T2WI than with MultiVane T2WI (p = 0.030) or RT-T2WI (p < 0.001). For detection of 86 hepatic lesions, sensitivity (mean, 97.7%) of MultiVane T2WI was significantly higher than that of BH-T2WI (mean, 89.5%) (p = 0.008) or RT-T2WI (mean, 84.9%) (p = 0.001). Applying the MultiVane technique to T2WI of the liver is a promising approach to improving image quality that results in increased detection of focal liver lesions compared with conventional T2WI.

  17. A light/dark cycle in the NICU accelerates body weight gain and shortens time to discharge in preterm infants.

    Science.gov (United States)

    Vásquez-Ruiz, Samuel; Maya-Barrios, José Alfonso; Torres-Narváez, Patricia; Vega-Martínez, Benito Rubén; Rojas-Granados, Adelina; Escobar, Carolina; Angeles-Castellanos, Manuel

    2014-09-01

    Bright constant light levels in the NICU may have negative effects on the growth and development of preterm infants The aim of this study is to evaluate the benefits of an alternating light/dark cycle in the NICU on weight gain and early discharge from the therapy in premature infants. A randomized interventional study was designed comparing infants in the NICU of Hospital Juarez de México, exposed from birth either to an LD environment (LD, n=19) or to the traditional continuous light (LL, n=19). The LD condition was achieved by placing individual removable helmets over the infant's heads. Body weight gain was analyzed, as the main indicator of stability and the main criteria for discharge in preterm infants born at 31.73±0.31week gestational age. Infants maintained in an LD cycle gained weight faster than infants in LL and therefore attained a shorter hospital stay, (34.37±3.12 vs 51.11±5.29days; P>0.01). Also, LD infants exhibited improved oxygen saturation and developed a daily melatonin rhythm. These findings provide a convenient alternative for establishing an LD environment for preterm healthy newborns in the NICU and confirm the beneficial effects of an alternating LD cycle for growth and weight gain and for earlier discharge time. Here we provide an easy and practical alternative to implement light/dark conditions in the NICU. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Magnetic resonance imaging of the cranial nerves in the posterior fossa: a comparative study of t2-weighted spin-echo sequences at 1.5 and 3.0 tesla.

    Science.gov (United States)

    Fischbach, F; Müller, M; Bruhn, H

    2008-04-01

    High-field magnetic resonance imaging (MRI) at 3.0 Tesla (T) is rapidly gaining clinical acceptance. Whether doubling of the field strength of 1.5T and the subsequent increase in signal-to-noise ratio (SNR) leads to a significant improvement of image quality is not automatically given. To evaluate the depiction of fine anatomic detail in the posterior fossa, focusing on brain nerves, on T2-weighted imaging, and to define the potential advantage of imaging at 3.0T versus 1.5T. In total, 10 brainstem nerve pairs of 12 volunteers were identified on T2-weighted MR images of 2- and 5-mm section thickness acquired at 1.5T and 3.0T. The MR images were compared for each subject at both field strengths by three independent readers who rated image quality according to depiction of anatomic detail and contrast by using a rating scale. In general, MR images at 3.0T were considered more conspicuous and less noisy than images at 1.5T. The SNR value measured was almost doubled. With respect to structural identification and contrast according to the rating scale, observer scores were significantly improved both for standard imaging with 5-mm sections and high-resolution imaging with 2-mm sections at 3.0T. Direct comparison revealed a significant increase for evaluated image quality criteria and the number of nerves detected. The comparison revealed a clear advantage in favor of T2-weighted MRI at 3.0T vs. 1.5T in depicting the roots and course of brain nerves in the posterior fossa.

  19. Evaluating dark energy probes using multidimensional dark energy parameters

    International Nuclear Information System (INIS)

    Albrecht, Andreas; Bernstein, Gary

    2007-01-01

    We investigate the value of future dark-energy experiments by modeling their ability to constrain the dark-energy equation of state. Similar work was recently reported by the Dark Energy Task Force (DETF) using a two dimensional parameterization of the equation-of-state evolution. We examine constraints in a nine-dimensional dark-energy parameterization, and find that the best experiments constrain significantly more than two dimensions in our 9D space. Consequently the impact of these experiments is substantially beyond that revealed in the DETF analysis, and the estimated cost per 'impact' drops by about a factor of 10 as one moves to the very best experiments. The DETF conclusions about the relative value of different techniques and of the importance of combining techniques are unchanged by our analysis

  20. Higgs exotic decays in general NMSSM with self-interacting dark matter

    Science.gov (United States)

    Wang, Wenyu; Zhang, Mengchao; Zhao, Jun

    2018-04-01

    Under current LHC and dark matter constraints, the general NMSSM can have self-interacting dark matter to explain the cosmological small structure. In this scenario, the dark matter is the light singlino-like neutralino (χ) which self-interacts through exchanging the light singlet-like scalars (h1,a1). These light scalars and neutralinos inevitably interact with the 125 GeV SM-like Higgs boson (hSM), which cause the Higgs exotic decays hSM → h1h1, a1a1, χχ. We first demonstrate the parameter space required by the explanation of the cosmological small structure and then display the Higgs exotic decays. We find that in such a parameter space the Higgs exotic decays can have branching ratios of a few percent, which should be accessible in the future e+e‑ colliders.