WorldWideScience

Sample records for t1-weighted dynamic contrast-enhanced

  1. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

    DEFF Research Database (Denmark)

    Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.

    2008-01-01

    Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast...... field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed...... inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values...

  2. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  3. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  4. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  5. Carcinoma of the uterine cervix. High-resolution turbo spin-echo MR imaging with contrast-enhanced dynamic scanning and T2-weighting

    International Nuclear Information System (INIS)

    Abe, Y.; Yamashita, Y.; Namimoto, T.; Takahashi, M.; Katabuchi, H.; Tanaka, N.; Okamura, H.

    1998-01-01

    Purpose: To compare high-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging with T2-weighted turbo spin-echo (TSE) imaging in the evaluation of uterine cervical carcinoma. Material and Methods: Thirty-two patients with cervical carcinoma underwent MR imaging on a 1.5 T superconductive unit to have the extension of the disease assessed before treatment. A phased-array coil was used in all patients. In 25 patients, surgical confirmation of the diagnosis was obtained after imaging. Radiation therapy was selected for the remaining 7 patients with advanced carcinoma. Qualitative and quantitative image analyses were also performed. Results: The cervical carcinomas showed maximum contrast in the cervical stroma and myometrium in the early dynamic phase. The tumor/cervical-stroma contrast in the early dynamic phase obtained with the T1-weighted TSE technique (contrast-to-noise ratio 22.6) was significantly higher than that obtained in T2-weighted TSE imaging (contrast-to-noise ratio 4.3). In the evaluation of parametrial invasion, the accuracy of T2-weighted imaging was 71.8% and contrast-enhanced dynamic imaging 81.2%. Conclusion: High-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging in cervical cancer offers improved tumor/cervical-stroma contrast and provides useful information on parametrial invasion. (orig.)

  6. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1-weighted perfusion MRI

    DEFF Research Database (Denmark)

    Larsson, Henrik B.W.; Vestergaard, Mark B.; Lindberg, Ulrich

    2017-01-01

    Purpose: Capillary transit time heterogeneity, measured as CTH, may set the upper limit for extraction of substances in brain tissue, e.g., oxygen. The purpose of this study was to investigate the feasibility of dynamic contrast-enhanced T1 weighted MRI (DCE-MRI) at 3 Tesla (T), in estimating CTH...

  7. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  8. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA-enhanced

  9. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols

    DEFF Research Database (Denmark)

    Tofts, P.S.; Brix, G; Buckley, D.L.

    1999-01-01

    We describe a standard set of quantity names and symbols related to the estimation of kinetic parameters from dynamic contrast-enhanced T(1)-weighted magnetic resonance imaging data, using diffusable agents such as gadopentetate dimeglumine (Gd-DTPA). These include a) the volume transfer constant K......-limited conditions K(trans) equals the blood plasma flow per unit volume of tissue; under permeability-limited conditions K(trans) equals the permeability surface area product per unit volume of tissue. We relate these quantities to previously published work from our groups; our future publications will refer...

  10. Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J [Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA (Netherlands)], E-mail: p.vos@rad.umcn.nl

    2010-03-21

    In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.

  11. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    Science.gov (United States)

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  12. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    Science.gov (United States)

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  13. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    Science.gov (United States)

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  14. Characterization of D-maltose as a T2 -exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-09-01

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med 80:1158-1164, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Detection of Local Tumor Recurrence After Definitive Treatment of Head and Neck Squamous Cell Carcinoma: Histogram Analysis of Dynamic Contrast-Enhanced T1-Weighted Perfusion MRI.

    Science.gov (United States)

    Choi, Sang Hyun; Lee, Jeong Hyun; Choi, Young Jun; Park, Ji Eun; Sung, Yu Sub; Kim, Namkug; Baek, Jung Hwan

    2017-01-01

    This study aimed to explore the added value of histogram analysis of the ratio of initial to final 90-second time-signal intensity AUC (AUCR) for differentiating local tumor recurrence from contrast-enhancing scar on follow-up dynamic contrast-enhanced T1-weighted perfusion MRI of patients treated for head and neck squamous cell carcinoma (HNSCC). AUCR histogram parameters were assessed among tumor recurrence (n = 19) and contrast-enhancing scar (n = 27) at primary sites and compared using the t test. ROC analysis was used to determine the best differentiating parameters. The added value of AUCR histogram parameters was assessed when they were added to inconclusive conventional MRI results. Histogram analysis showed statistically significant differences in the 50th, 75th, and 90th percentiles of the AUCR values between the two groups (p Histogram analysis of AUCR can improve the diagnostic yield for local tumor recurrence during surveillance after treatment for HNSCC.

  16. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  17. Role of MR imaging in the differentiation of benign and nonbenign intracranial meningiomas. The utility of contrast-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Matsuo, Michimasa

    1996-01-01

    The purpose of this study was to develop useful criteria for distinguishing nonbenign (atypical and malignant) primary intracranial meningiomas from their benign counterparts by using magnetic resonance imaging (MRI). To determine useful MRI findings for this purpose, 12 benign and five nonbenign meningiomas were retrospectively evaluated according to the following items: tumor signal intensity on plain T1-, T2- and proton density-weighted images, degree of perifocal edema on T2-weighted images, morphology of the tumor margin on contrast-enhanced T1-weighted images, presence of irregular nodule and/or mushrooming pattern on contrast-enhanced T1-weighted images, homogeneity of the tumor on contrast-enhanced T1-weighted images, and presence of marked skull destruction. Markedly irregular tumor margin, presence of irregular nodule and/or mushrooming pattern and markedly inhomogeneous enhancing pattern were significantly more frequent in nonbenign meningiomas. We defined these three MRI findings as nonbenign findings, and tried to categorize meningiomas by the number of nonbenign findings. It was found that 10 meningiomas with no or one nonbenign finding were benign lesions, of four meningiomas with two nonbenign findings two were benign lesions and two were nonbenign lesions, and three meningiomas with three nonbenign findings were nonbenign lesions. The two benign meningiomas with two nonbenign findings were accompanied by increased mitotic activity or brain invasion. Contrast-enhanced T1-weighted images were considered very useful in distinguishing benign and nonbenign meningiomas. (author)

  18. Dynamic contrast enhanced MRI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alonzi, Roberto [Marie Curie Research Wing, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom)], E-mail: robertoalonzi@btinternet.com; Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom); Synarc Inc. 575 Market Street, San Francisco, CA 94105 (United States)], E-mail: anwar.padhani@paulstrickland-scannercentre.org.uk; Allen, Clare [Department of Imaging, University College Hospital, London, 235 Euston Road, NW1 2BU (United Kingdom)], E-mail: clare.allen@uclh.nhs.uk

    2007-09-15

    Angiogenesis is an integral part of benign prostatic hyperplasia (BPH), is associated with prostatic intraepithelial neoplasia (PIN) and is key to the growth and for metastasis of prostate cancer. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) using small molecular weight gadolinium chelates enables non-invasive imaging characterization of tissue vascularity. Depending on the technique used, data reflecting tissue perfusion, microvessel permeability surface area product, and extracellular leakage space can be obtained. Two dynamic MRI techniques (T{sub 2}*-weighted or susceptibility based and T{sub 1}-weighted or relaxivity enhanced methods) for prostate gland evaluations are discussed in this review with reference to biological basis of observations, data acquisition and analysis methods, technical limitations and validation. Established clinical roles of T{sub 1}-weighted imaging evaluations will be discussed including lesion detection and localisation, for tumour staging and for the detection of suspected tumour recurrence. Limitations include inadequate lesion characterisation particularly differentiating prostatitis from cancer, and in distinguishing between BPH and central gland tumours.

  19. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  20. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  1. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    Science.gov (United States)

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (Pspot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  2. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  3. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  4. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    International Nuclear Information System (INIS)

    Gilles, R.; Garnier, C.; Meingan, P.; Zemoura, L.; Lucidarme, O.; Guinebretiere, J.M.; Tardivon, A.A.; Arriagada, R.

    1995-01-01

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  5. Optimal MR pulse sequences for hepatic hemangiomas : comparison of T2-weighted turbo-spin-echo, T2-weighted breath-hold turbo-spin-echo, and T1-weighted FLASH dynamic imaging

    International Nuclear Information System (INIS)

    Wang, Wen Chao; Choi, Byung Ihn; Han, Joon Koo; Kim, Tae Kyoung; Cho, Soon Gu

    1997-01-01

    To optimize MR imaging pulse sequences in the imaging of hepatic hemangioma and to evaluate on dynamic MR imaging the enhancing characteristics of the lesions. Twenty patients with 35 hemangiomas were studied by using Turbo-spin-echo (TSE) sequence (T2-weighted, T2- and heavily T2-weighted breath-hold) and T1-weighted FLASH imaging acquired before, immediately on, and 1, 3 and 5 minutes after injection of a bolus of Gd-DTPA (0.1mmol/kg). Phased-array multicoil was employed. Images were quantitatively analyzed for lesion-to-liver signal difference to noise ratios (SD/Ns), and lesion-to-liver signal ratios (H/Ls), and qualitatively analyzed for lesion conspicuity. The enhancing characteristics of the hemangiomas were described by measuring the change of signal intensity as a curve in T1-weighted FLASH dynamic imaging. For T2-weighted images, breath-hold T2-weighted TSE had a slightly higher SD/N than other pulse sequences, but there was no statistical difference in three fast pulse sequences (p=0.211). For lesion conspicuity, heavily T2-weighted breath-hold TSE images was superior to T2-weighted breath-hold or non-breath-hold TSE (H/L, 5.75, 3.81, 2.87, respectively, p<0.05). T2-weighted breath-hold TSE imaging was more effective than T2-weighted TSE imaging in removing lesion blurring or lack of sharpness, and there was a 12-fold decrease in acquisition time (20sec versus 245 sec). T1-weighted FLASH dynamic images of normal liver showed peak enhancement at less than 1 minute, and of hemangioma at more than 3 minutes;the degree of enhancement for hemangioma decreased after a 3 minute delay. T2-weighed breath-hold TSE imaging and Gd-DTPA enhanced FLASH dynamic imaging with 5 minutes delay are sufficient for imaging hepatic hemangiomas

  6. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  7. Endometrial cancer with cervical stromal invasion: diagnostic accuracy of diffusion-weighted and dynamic contrast enhanced MR imaging at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Gigin; Lu, Hsin-Ying [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chang Gung Memorial Hospital at Linkou, Clinical Phenome Center, Guishan, Taoyuan (China); Huang, Yu-Ting; Lin, Yu-Chun; Ng, Shu-Hang; Ng, Koon-Kwan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chao, Angel; Lai, Chyong-Huey [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Obstetrics and Gynecology and Gynecologic Cancer Research Center, Guishan, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Clinical Trial Center, Guishan, Taoyuan (China); Wu, Ren-Chin [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Pathology, Guishan, Taoyuan (China)

    2017-05-15

    To compare the diagnostic accuracy of diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging for detecting cervical stromal invasion in endometrial cancer. Eighty-three consecutive women with endometrial cancer underwent preoperative evaluation in a 3-T unit, including T2-weighted, DW (b = 0 and 1000 s/mm{sup 2}), and DCE MR imaging. Two radiologists independently assessed presence of cervical stromal invasion, with histopathological reference as gold standard. For assessing cervical stromal invasion, the diagnostic accuracy, sensitivity, and specificity, respectively for Reader 1/Reader 2, were as follows: DW MR imaging - 95.2 %/91.6 %, 91.7 %/100 %, and 95.8 %/90.1 %; DCE MR imaging - 91.6 %/88 %, 58.3 %/50 %, and 97.2 %/94.4 %. The diagnostic performance of DW MR imaging (Reader 1: areas under the receiver operating characteristic curve (AUC) = 0.98; Reader 2: AUC = 0.97) was significantly higher than that of DCE MR imaging (p = 0.009 for Reader 2) or T2-weighted MR imaging (Reader 1: p = 0.006; Reader 2: p = 0.013). Patients with cervical stromal invasion showed a significantly greater canal width (p < 0.0001) and myometrial invasion extent (p = 0.006). DW MR imaging has superior diagnostic performance compared with DCE MR imaging in the detection of cervical stromal invasion. (orig.)

  8. Accurate determination of blood–brain barrier permeability using dynamic contrast-enhanced T1-weighted MRI

    DEFF Research Database (Denmark)

    Cramer, Stig P; Larsson, Henrik B W

    2014-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly used to estimate permeability in situations with subtle blood-brain barrier (BBB) leakage. However, the method's ability to differentiate such low values from zero is unknown, and no consensus exists on optimal selection...

  9. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  10. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    Science.gov (United States)

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  11. Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chandarana, Hersh; Block, Kai T.; Winfeld, Matthew J.; Lala, Shailee V.; Mazori, Daniel; Giuffrida, Emalyn; Babb, James S.; Milla, Sarah S. [New York University Langone Medical Center, Department of Radiology, New York, NY (United States)

    2014-02-15

    To compare the image quality of contrast-enhanced abdominopelvic 3D fat-suppressed T1-weighted gradient-echo imaging with radial and conventional Cartesian k-space acquisition schemes in paediatric patients. Seventy-three consecutive paediatric patients were imaged at 1.5 T with sequential contrast-enhanced T1-weighted Cartesian (VIBE) and radial gradient echo (GRE) acquisition schemes with matching parameters when possible. Cartesian VIBE was acquired as a breath-hold or as free breathing in patients who could not suspend respiration, followed by free-breathing radial GRE in all patients. Two paediatric radiologists blinded to the acquisition schemes evaluated multiple parameters of image quality on a five-point scale, with higher score indicating a more optimal examination. Lesion presence or absence, conspicuity and edge sharpness were also evaluated. Mixed-model analysis of variance was performed to compare radial GRE and Cartesian VIBE. Radial GRE had significantly (all P < 0.001) higher scores for overall image quality, hepatic edge sharpness, hepatic vessel clarity and respiratory motion robustness than Cartesian VIBE. More lesions were detected on radial GRE by both readers than on Cartesian VIBE, with significantly higher scores for lesion conspicuity and edge sharpness (all P < 0.001). Radial GRE has better image quality and lesion conspicuity than conventional Cartesian VIBE in paediatric patients undergoing contrast-enhanced abdominopelvic MRI. (orig.)

  12. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  13. Gadolinium-enhanced MR imaging of normal renal transplants. An evaluation of a T1-weighted dynamic echo-planar sequence

    International Nuclear Information System (INIS)

    Dupas, B.; Blancho, G.; Havet, T.; Leaute, F.

    1999-01-01

    Purpose: To evaluate the potential usefulness of dynamic MR with echoplanar imaging (EPI) in assessing the renal function in patients with renal allografts. Material and methods: Using a T1-weighted sequence, EPI was performed after injection of a Gd-chelate in 17 patients with normally functioning renal allografts. Time-intensity curves were plotted from the signal intensity (SI) measurements of the cortex and the medulla. Results: The pattern of corticomedullar differentiation (CMD) observed after constrast enhancement was divided into four phases using the T1-EPI. After a rapid decrease in the SI of cortical structures, and a subsequent return to precontrast levels, a gradual fall in the SI of the medulla was observed. The average time between the two periods of signal loss was 60 s. Conclusion: This study illustrated the potential use of dynamic T1-EPI to demonstrate contrast-induced CMD in renal allografts. (orig.)

  14. Dynamic Quantitative T1 Mapping in Orthotopic Brain Tumor Xenografts

    Directory of Open Access Journals (Sweden)

    Kelsey Herrmann

    2016-04-01

    Full Text Available Human brain tumors such as glioblastomas are typically detected using conventional, nonquantitative magnetic resonance imaging (MRI techniques, such as T2-weighted and contrast enhanced T1-weighted MRI. In this manuscript, we tested whether dynamic quantitative T1 mapping by MRI can localize orthotopic glioma tumors in an objective manner. Quantitative T1 mapping was performed by MRI over multiple time points using the conventional contrast agent Optimark. We compared signal differences to determine the gadolinium concentration in tissues over time. The T1 parametric maps made it easy to identify the regions of contrast enhancement and thus tumor location. Doubling the typical human dose of contrast agent resulted in a clearer demarcation of these tumors. Therefore, T1 mapping of brain tumors is gadolinium dose dependent and improves detection of tumors by MRI. The use of T1 maps provides a quantitative means to evaluate tumor detection by gadolinium-based contrast agents over time. This dynamic quantitative T1 mapping technique will also enable future quantitative evaluation of various targeted MRI contrast agents.

  15. Detection of acute avascular necrosis with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Nadel, S.N.; Richardson, W.J.; Martinez, S.; Rizk, W.S.; Malizos, K.; Debatin, J.F.

    1991-01-01

    Early detection of avascular necrosis (AVN) may allow earlier intervention and lead to improved treatment success. This paper is designed to compare standard and dynamic contrast-enhanced MR imaging in the detection of acute AVN. A previously described animal model of AVN was used. Five anesthetized dogs underwent right femoral head devascularization, including placement of a supercooling coil around the femoral neck. Within 3 hours the dogs were imaged in a 1.5-T Signa magnet. Standard T1-weighted, T2-weighted, and STIR images were obtained through both hips. A DiGrass sequence with 30 sequential 3.2-second T1-weighted images was used, and 0.2 mmol/kg gadoteridol was injected intravenously at the start of the sequence at 2 mL/sec with an automated injector. Following imaging, oxytetracycline was given intravenously. After 3 days the dogs were killed, and their femoral heads were extracted, coronally sectioned, and analyzed for fluorescence. T1-weighted, T2-weighted, and STIR sequences showed no marrow abnormalities on either the normal or the operated-on side. With contrast material injection, all normal areas and the unoperated portion the femoral neck and diaphysis enhanced markedly 4-9 seconds following the bolus

  16. Comparison of dynamic contrast-enhanced MRI parameters of breast lesions at 1.5 and 3.0 T: a pilot study

    Science.gov (United States)

    Pineda, F D; Medved, M; Fan, X; Ivancevic, M K; Abe, H; Shimauchi, A; Newstead, G M

    2015-01-01

    Objective: To compare dynamic contrast-enhanced (DCE) MRI parameters from scans of breast lesions at 1.5 and 3.0 T. Methods: 11 patients underwent paired MRI examinations in both Philips 1.5 and 3.0 T systems (Best, Netherlands) using a standard clinical fat-suppressed, T1 weighted DCE-MRI protocol, with 70–76 s temporal resolution. Signal intensity vs time curves were fit with an empirical mathematical model to obtain semi-quantitative measures of uptake and washout rates as well as time-to-peak enhancement (TTP). Maximum percent enhancement and signal enhancement ratio (SER) were also measured for each lesion. Percent differences between parameters measured at the two field strengths were compared. Results: TTP and SER parameters measured at 1.5 and 3.0 T were similar; with mean absolute differences of 19% and 22%, respectively. Maximum percent signal enhancement was significantly higher at 3 T than at 1.5 T (p = 0.006). Qualitative assessment showed that image quality was significantly higher at 3 T (p = 0.005). Conclusion: Our results suggest that TTP and SER are more robust to field strength change than other measured kinetic parameters, and therefore measurements of these parameters can be more easily standardized than measurements of other parameters derived from DCE-MRI. Semi-quantitative measures of overall kinetic curve shape showed higher reproducibility than do discrete classification of kinetic curve early and delayed phases in a majority of the cases studied. Advances in knowledge: Qualitative measures of curve shape are not consistent across field strength even when acquisition parameters are standardized. Quantitative measures of overall kinetic curve shape, by contrast, have higher reproducibility. PMID:25785918

  17. Evaluation of conventional, dynamic contrast enhanced and diffusion weighted MRI for quantitative Crohn's disease assessment with histopathology of surgical specimens

    NARCIS (Netherlands)

    Tielbeek, Jeroen A. W.; Ziech, Manon L. W.; Li, Zhang; Lavini, Cristina; Bipat, Shandra; Bemelman, Willem A.; Roelofs, Joris J. T. H.; Ponsioen, Cyriel Y.; Vos, Frans M.; Stoker, Jaap

    2014-01-01

    To prospectively compare conventional MRI sequences, dynamic contrast enhanced (DCE) MRI and diffusion weighted imaging (DWI) with histopathology of surgical specimens in Crohn's disease. 3-T MR enterography was performed in consecutive Crohn's disease patients scheduled for surgery within 4 weeks.

  18. Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.

    Science.gov (United States)

    Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2010-08-01

    The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of pancreatic cancer by multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging at 3.0 T

    International Nuclear Information System (INIS)

    Yao, Xiuzhong; Zeng, Mengsu; Wang, He; Sun, Fei; Rao, Shengxiang; Ji, Yuan

    2012-01-01

    Objective: To investigate the microcirculation in pancreatic cancer by pharmacokinetic analysis of multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging at 3.0 T. Materials and methods: Multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging was performed in 40 healthy volunteers and 40 patients with pancreatic cancer proven by histopathology using an axial three-dimensions fat-saturated T1-weighted spoiled-gradient echo sequence at 3.0 T. A two compartment model with T1 correction was used to quantify the transfer constant, the rate constant of backflux from the extravascular extracellular space to the plasma and the extravascular extracellular space fractional volume in pancreatic cancer, obstructive pancreatitis distal to the malignant tumor, adjacent pancreatic tissue proximal to the tumor and normal pancreas. All parameters were statistically analyzed. Results: Statistical differences were noticed in both the transfer constant (p = 0.000075) and the rate constant of backflux (p = 0.006) among different tissues. Both the transfer constant and the rate constant of backflux in pancreatic cancer were statistically lower than those in normal pancreas and adjacent pancreatic tissue (p < 0.05). Both the transfer constant and the rate constant of backflux in obstructive pancreatitis were statistically lower than those in normal pancreas and adjacent pancreatic tissue (p < 0.05). The extravascular extracellular space fractional volume in pancreatic cancer was statistically lager than that in normal pancreas (p = 0.002). Conclusion: Multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging offers a useful technique to evaluate the microenvironment in pancreatic cancer at 3.0 T. Compared to normal pancreas, pancreatic cancer has lower transfer constant, rate constant of backflux and larger extravascular extracellular space fractional volume.

  20. Evaluation of pancreatic cancer by multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Xiuzhong, E-mail: yao.xiuzhong@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital of Fudan University and Department of Medical Image, Shanghai Medical College of Fudan University, No. 138, Fenglin Road, Xuhui District, Shanghai 200032 (China); Zeng, Mengsu, E-mail: zengmengsu@gmail.com [Department of Radiology, Zhongshan Hospital of Fudan University and Department of Medical Image, Shanghai Medical College of Fudan University, No. 138, Fenglin Road, Xuhui District, Shanghai 200032 (China); Wang, He, E-mail: herry258@hotmail.com [Global Applied Science Laboratory of GE Healthcare, No. 1, Huatuo Road, Zhangjiang Hi-tech Park, Pudong District, Shanghai 201203 (China); Sun, Fei, E-mail: fei.sun@med.ge.com [Global Applied Science Laboratory of GE Healthcare, No. 1, Huatuo Road, Zhangjiang Hi-tech Park, Pudong District, Shanghai 201203 (China); Rao, Shengxiang, E-mail: rao.shengxiang@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital of Fudan University and Department of Medical Image, Shanghai Medical College of Fudan University, No. 138, Fenglin Road, Xuhui District, Shanghai 200032 (China); Ji, Yuan, E-mail: Ji.yuan@zs-hospital.sh.cn [Department of Pathology, Zhongshan Hospital of Fudan University, No. 138, Fenglin Road, Xuhui District, Shanghai 200032 (China)

    2012-08-15

    Objective: To investigate the microcirculation in pancreatic cancer by pharmacokinetic analysis of multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging at 3.0 T. Materials and methods: Multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging was performed in 40 healthy volunteers and 40 patients with pancreatic cancer proven by histopathology using an axial three-dimensions fat-saturated T1-weighted spoiled-gradient echo sequence at 3.0 T. A two compartment model with T1 correction was used to quantify the transfer constant, the rate constant of backflux from the extravascular extracellular space to the plasma and the extravascular extracellular space fractional volume in pancreatic cancer, obstructive pancreatitis distal to the malignant tumor, adjacent pancreatic tissue proximal to the tumor and normal pancreas. All parameters were statistically analyzed. Results: Statistical differences were noticed in both the transfer constant (p = 0.000075) and the rate constant of backflux (p = 0.006) among different tissues. Both the transfer constant and the rate constant of backflux in pancreatic cancer were statistically lower than those in normal pancreas and adjacent pancreatic tissue (p < 0.05). Both the transfer constant and the rate constant of backflux in obstructive pancreatitis were statistically lower than those in normal pancreas and adjacent pancreatic tissue (p < 0.05). The extravascular extracellular space fractional volume in pancreatic cancer was statistically lager than that in normal pancreas (p = 0.002). Conclusion: Multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging offers a useful technique to evaluate the microenvironment in pancreatic cancer at 3.0 T. Compared to normal pancreas, pancreatic cancer has lower transfer constant, rate constant of backflux and larger extravascular extracellular space fractional volume.

  1. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U.; Grobholz, R.; Heilmann, M.; Michel, M.S.; Trojan, L.; Werner, A.; Rabe, J.; Schlemmer, H.P.

    2003-01-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k ep ).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k ep . Prostate carcinomas of the peripheral zone were demarcated by amplitude and k ep . In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k ep and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k ep reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [de

  2. Differentiating benign and malignant breast lesions with T2*-weighted first pass perfusion imaging

    International Nuclear Information System (INIS)

    Kvistad, K.A.; Smenes, E.; Haraldseth, O.; Lundgren, S.; Fjoesne, H.E.; Smethurst, H.B.

    1999-01-01

    Purpose: Invasive breast carcinomas and fibroadenomas are often difficult to differentiate in dynamic contrast-enhanced T1-weighted MR imaging of the breast, because both tumors can enhance strongly after contrast injection. The purpose of this study was to evaluate whether the addition of T2*-weighted first pass perfusion imaging can increase the differentiation of malignant from benign lesions. Material and Methods: Nine patients with invasive carcinomas and 10 patients with contrast enhancing fibroadenomas were examined by a dynamic contrast-enhanced T1-weighted 3D sequence immediately followed by a single slice T2*-weighted first pass perfusion sequence positioned in the contrast-enhancing lesion. Results: The carcinomas and the fibroadenomas were impossible to differentiate based on the contrast enhancement characteristics in the T1-weighted sequence. The signal loss in the T2*-weighted perfusion sequence was significantly stronger in the carcinomas than in the fibroadenomas (p=0.0004). Conclusion: Addition of a T2*-weighted first pass perfusion sequence with a high temporal resolution can probably increase the differentiation of fibroadenomas from invasive carcinomas in contrast-enhanced MR imaging of the breast. (orig.)

  3. Assessment of inflammatory activity in Crohn's disease by means of dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Pupillo, V A; Di Cesare, E; Frieri, G; Limbucci, N; Tanga, M; Masciocchi, C

    2007-09-01

    Our aim was to perform a dynamic study of contrast enhancement of the intestinal wall in patients with Crohn's disease to quantitatively assess local inflammatory activity. We studied a population of 50 patients with histologically proven Crohn's disease. Magnetic resonance imaging (MRI) was performed using a 1.5-T magnet with a phased-array coil and acquisition of T2-weighted single-shot fast spin echo (SSFSE) half Fourier sequences before intravenous administration of gadolinium, and T1-weighted fast spoiled gradient (FSPGR) fat-saturated sequences before and after contrast administration. Before the examination, patents received oral polyethylene glycol (PEG) (1,000 ml for adults; 10 ml/Kg of body weight for children). Regions of interest (ROI) were placed on the normal and diseased intestinal wall to assess signal intensity and rate of increase in contrast enhancement over time. Data were compared with the Crohn's Disease Activity Index (CDAI). The diseased bowel wall showed early and intense uptake of contrast that increases over time until a plateau is reached. In patients in the remission phase after treatment, signal intensity was only slightly higher in diseased bowel loops than in healthy loops. There was a significant correlation between the peak of contrast uptake and CDAI. Dynamic MRI is a good technique for quantifying local inflammatory activity of bowel wall in patients with Crohn's disease.

  4. Gadoxate-enhanced T1-weighted MR cholangiography: comparison of 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, C.; Schima, W.; Weber, M.; Mang, T.; Nemec, S.; Kulinna-Cosentini, C.; Bastati, N.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2009-06-15

    Purpose: to qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5 T and 3.0 T. Materials and methods: a total of 40 patients with a non-dilated biliary system were retrospectively included in the study. T1-weighted MR cholangiography 20 min after IV administration of 0.025 mmol/kg gadoxate (Primovist trademark) was performed in 20 patients at 1.5 T and in another 20 patients at 3.0 T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct - LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: the CNRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0 T. Qualitative analysis showed a significant superiority for 3.0 T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). (orig.)

  5. Value of fat suppression and dynamic contrast-enhanced MRI in the diagnosis of insulinoma

    International Nuclear Information System (INIS)

    Xu Zengbin; Ruan Lingxiang; Peng Zhiyi; Zhang Minming; Xu Shunliang; Zhang Xidao

    2003-01-01

    Objective: To evaluate the value of fat suppression and dynamic contrast-enhanced MRI in the preoperative localization of insulinoma. Methods: Twelve cases with pathologically proven insulinoma were evaluated with MRI. SE T 1 WI, FSE T 2 WI, T 1 WI and T 2 WI with fat suppression, dynamic contrast-enhanced FMPSPGR sequences were used in MR scanning. Results: On SE T 1 WI, the lesions displayed hypointense in 4, isointense in 8 cases. Lesions showed hyperintense in 4, isointense in 8 cases on FSE T 2 WI. In contrast, 7 cases appeared as hypointense on T 1 WI with fat suppression and 6 cases appeared as hyperintense on T 2 WI with fat suppression. With dynamic contrast-enhanced FMPSPGR sequence 11 of 12 insulinomas were detected. In the arterial phase, the lesions presented as hyperintense with different degrees in 11 cases and isointense in 1 case. 6 cases remained hyperintense and 6 cases were isointense in pancreatic parenchymal and portal phase. 4 lesions were identified only in dynamic enhancement images. The diagnostic accuracy of insulinoma by dynamic contrast-enhanced MRI was 91.7% (11/12) as compared with histological study. Conclusion: The results indicate that dynamic contrast-enhanced MRI is an sensitive and accurate method for the preoperative localization of insulinoma

  6. Diagnostic Utility of Contrast-enhanced 3D T1-weighted Imaging in Acute Cerebral Infarction Associated with Graves Disease.

    Science.gov (United States)

    Gon, Yasufumi; Sakaguchi, Manabu; Oyama, Naoki; Mochizuki, Hideki

    2017-02-01

    Graves disease is rarely complicated with cerebrovascular steno-occlusive diseases. Previous studies have suggested several hypotheses for this occurrence, including excess thyroid hormone, which stimulates the sympathetic nervous system, which in turn causes an abnormal hemodynamic response with consequent atherosclerotic changes, and antithyroid antibodies cause local vascular inflammation in patients with Graves disease. However, radiological findings of vasculitis in patients with Graves disease and cerebral infarction remain less known. We report the case of a 30-year-old Japanese woman with acute cerebral infarction due to vasculitis associated with Graves disease. She was admitted to our hospital with a 4-day history of intermittent transient dysarthria and limb shaking of the left leg when standing. Three weeks before admission, she went to a local hospital because of general malaise and was diagnosed with Graves disease. Neurological examination revealed paralytic dysarthria, left central facial nerve palsy, and left hemiparesis (manual muscle testing, 4 of 5). Blood examinations showed hyperthyroidism (thyroid-stimulating hormone ≤.010 µU/mL; free T3 ≥25.0 pg/mL; free T4 ≥8.0 ng/dL) and elevation of antithyroid antibody levels (thyroid peroxidase antibody, 87 IU/mL). The vessel wall of the right internal carotid artery was markedly enhanced on contrast-enhanced three-dimensional T1-weighted magnetic resonance imaging, suggesting vasculitis. Magnetic resonance angiography revealed right internal carotid artery occlusion after the branching ophthalmic artery. Arterial stenosis due to vasculitis was considered the cause of hemodynamic ischemic stroke. Vessel wall imaging such as high-resolution contrast-enhanced T1-weighted imaging seems useful for assessing the underlying mechanism of stroke in patients with Graves disease. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20.

  8. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    International Nuclear Information System (INIS)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won

    1997-01-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20

  9. Comparison of contrast-enhanced T1-weighted and 3D constructive interference in steady state images for predicting outcome after hearing-preservation surgery for vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Kocaoglu, M.; Bulakbasi, N.; Ucoz, T.; Ustunsoz, B.; Tayfun, C.; Somuncu, I. [GATA Department of Radiology, 06018, Etlik, Ankara (Turkey); Pabuscu, Y. [Department of Radiology, Celal Bayar University, Manisa (Turkey)

    2003-07-01

    We compared contrast-enhanced T1-weighted and 3D constructive interference in steady state (CISS) sequences for demonstrating possible prognostic factors in hearing-preservation surgery for vestibular schwannoma. We studied 22 patients with vestibular schwannomas having hearing-preservation surgery. Postoperatively six (27%) had a facial palsy and eight (36%) had hearing loss. There was a significant correlation between the size of the tumour and facial palsy (r=-0.72). Both techniques adequately demonstrated all tumours. Involvement of the fundus of the internal auditory canal (IAC) and a small distance between the lateral border of the tumour and the fundus were correlated significantly with hearing loss (r=-0.81 and -0.75, respectively). The 3D-CISS sequence, by virtue of its high contrast resolution was superior to T1-weighted images (P<0.05) for detection of the fundal involvement. The direction of displacement of the facial nerve did not correlate with facial palsy or hearing loss. We think that 3D-CISS images better show the features influencing surgical outcome, but that contrast-enhanced T1-weighted images are required for diagnosis. (orig.)

  10. Comparison of contrast-enhanced T1-weighted and 3D constructive interference in steady state images for predicting outcome after hearing-preservation surgery for vestibular schwannoma

    International Nuclear Information System (INIS)

    Kocaoglu, M.; Bulakbasi, N.; Ucoz, T.; Ustunsoz, B.; Tayfun, C.; Somuncu, I.; Pabuscu, Y.

    2003-01-01

    We compared contrast-enhanced T1-weighted and 3D constructive interference in steady state (CISS) sequences for demonstrating possible prognostic factors in hearing-preservation surgery for vestibular schwannoma. We studied 22 patients with vestibular schwannomas having hearing-preservation surgery. Postoperatively six (27%) had a facial palsy and eight (36%) had hearing loss. There was a significant correlation between the size of the tumour and facial palsy (r=-0.72). Both techniques adequately demonstrated all tumours. Involvement of the fundus of the internal auditory canal (IAC) and a small distance between the lateral border of the tumour and the fundus were correlated significantly with hearing loss (r=-0.81 and -0.75, respectively). The 3D-CISS sequence, by virtue of its high contrast resolution was superior to T1-weighted images (P<0.05) for detection of the fundal involvement. The direction of displacement of the facial nerve did not correlate with facial palsy or hearing loss. We think that 3D-CISS images better show the features influencing surgical outcome, but that contrast-enhanced T1-weighted images are required for diagnosis. (orig.)

  11. MR mammography for diagnosis of breast cancer. Evaluation of usefulness of contrast-enhanced fat-suppressed T1 weight image

    International Nuclear Information System (INIS)

    Kusama, Ritsu; Takayama, Fumiyoshi; Tsuchiya, Shin-ichi

    2005-01-01

    We assessed the value of contrast-enhanced fat-suppressed T1 weight images (CFT1) in diagnosing breast cancers showing mass-like lesions in MR imaging. MR imaging demonstrated 41 carcinoma and 15 fibroadenoma cases. We classified these into 3 groups based on the status of the border and the adjacent zone in CFT1: a well-defined border, an ill-defined border, and linear high signal intensity in the adjacent zone. In carcinoma cases, 23 showed well-defined borders and 18 showed linear high signal intensity in adjacent zone. In fibroadenoma cases, 14 cases revealed well-defined borders and one case an ill-defined border. We compared the borders and adjacent zones of tumors in CFT1 with the pathological findings. Cases of fibroadenoma with well-defined borders in CFT1 showed well-circumscribed nodules with no infiltration of surrounding lymphocytes and fibroblast Cases of carcinoma with ill-defined borders showed infiltration by tumor cells to adjacent tissue without lymphocytes. Cases of carcinoma with linear high signal intensity in the adjacent zone revealed infiltration of the lymph cells and fibroblasts cells in the adjacent zone. The linear high signal intensity was distinguishable from the peripheral enhancement in dynamic MR images. We conclude that the borders and adjacent zones of tumors in CFT1 are useful for diagnosis. (authors)

  12. Pre-treatment functional MRI of breast cancer: T2* evaluation at 3 T and relationship to dynamic contrast-enhanced and diffusion-weighted imaging.

    Science.gov (United States)

    Kousi, Evanthia; O'Flynn, Elizabeth A M; Borri, Marco; Morgan, Veronica A; deSouza, Nandita M; Schmidt, Maria A

    2018-05-31

    Baseline T2* relaxation time has been proposed as an imaging biomarker in cancer, in addition to Dynamic Contrast-Enhanced (DCE) MRI and diffusion-weighted imaging (DWI) parameters. The purpose of the current work is to investigate sources of error in T2* measurements and the relationship between T2* and DCE and DWI functional parameters in breast cancer. Five female volunteers and thirty-two women with biopsy proven breast cancer were scanned at 3 T, with Research Ethics Committee approval. T2* values of the normal breast were acquired from high-resolution, low-resolution and fat-suppressed gradient-echo sequences in volunteers, and compared. In breast cancer patients, pre-treatment T2*, DCE MRI and DWI were performed at baseline. Pathologically complete responders at surgery and non-responders were identified and compared. Principal component analysis (PCA) and cluster analysis (CA) were performed. There were no significant differences between T2* values from high-resolution, low-resolution and fat-suppressed datasets (p > 0.05). There were not significant differences between baseline functional parameters in responders and non-responders (p > 0.05). However, there were differences in the relationship between T2* and contrast-agent uptake in responders and non-responders. Voxels of similar characteristics were grouped in 5 clusters, and large intra-tumoural variations of all parameters were demonstrated. Breast T2* measurements at 3 T are robust, but spatial resolution should be carefully considered. T2* of breast tumours at baseline is unrelated to DCE and DWI parameters and contribute towards describing functional heterogeneity of breast tumours. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Quantitative evaluation of contrast agent uptake in standard fat-suppressed dynamic contrast-enhanced MRI examinations of the breast.

    Science.gov (United States)

    Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A

    2018-01-01

    To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P contrast T 1 values, potentially related to their infiltrative growth pattern. This work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The

  14. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  15. Comparison between the Prebolus T1 Measurement and the Fixed T1 Value in Dynamic Contrast-Enhanced MR Imaging for the Differentiation of True Progression from Pseudoprogression in Glioblastoma Treated with Concurrent Radiation Therapy and Temozolomide Chemotherapy.

    Science.gov (United States)

    Nam, J G; Kang, K M; Choi, S H; Lim, W H; Yoo, R-E; Kim, J-H; Yun, T J; Sohn, C-H

    2017-12-01

    Glioblastoma is the most common primary brain malignancy and differentiation of true progression from pseudoprogression is clinically important. Our purpose was to compare the diagnostic performance of dynamic contrast-enhanced pharmacokinetic parameters using the fixed T1 and measured T1 on differentiating true from pseudoprogression of glioblastoma after chemoradiation with temozolomide. This retrospective study included 37 patients with histopathologically confirmed glioblastoma with new enhancing lesions after temozolomide chemoradiation defined as true progression ( n = 15) or pseudoprogression ( n = 22). Dynamic contrast-enhanced pharmacokinetic parameters, including the volume transfer constant, the rate transfer constant, the blood plasma volume per unit volume, and the extravascular extracellular space per unit volume, were calculated by using both the fixed T1 of 1000 ms and measured T1 by using the multiple flip-angle method. Intra- and interobserver reproducibility was assessed by using the intraclass correlation coefficient. Dynamic contrast-enhanced pharmacokinetic parameters were compared between the 2 groups by using univariate and multivariate analysis. The diagnostic performance was evaluated by receiver operating characteristic analysis and leave-one-out cross validation. The intraclass correlation coefficients of all the parameters from both T1 values were fair to excellent (0.689-0.999). The volume transfer constant and rate transfer constant from the fixed T1 were significantly higher in patients with true progression ( P = .048 and .010, respectively). Multivariate analysis revealed that the rate transfer constant from the fixed T1 was the only independent variable (OR, 1.77 × 10 5 ) and showed substantial diagnostic power on receiver operating characteristic analysis (area under the curve, 0.752; P = .002). The sensitivity and specificity on leave-one-out cross validation were 73.3% (11/15) and 59.1% (13/20), respectively. The dynamic

  16. The usefulness of T2-weighted MR urography and contrast enhanced MR urography in the evaluation of obstructive uropathy: comparisonal study with antegrade pyelography

    International Nuclear Information System (INIS)

    Oh, Chang Hoon; Lee, Jeong Min; Jin, Kong Yong; Chung, Gyung Ho; Cho, Seung Il; Lee, Sang Hun; Kim, Young Kon; Oh, Gyung Jae

    2002-01-01

    To compare the efficacy of contrast-enhanced and T2-weighted magnetic resonance urography (MRU) for the depiction of obstruction and evaluation of the causes of obstructive uropathy with that of antegrade pyelography. Twenty-five patients with obstructive uropathy who underwent percutaneous nephrostomy (PCN) and antegrade pyelography( AGP) were included in the study. We performed MR urography, comprising half-Fourier acquisition single-shot turbo spin-echo (HASTE) T2- weighted imaging and 3-D fast imaging with steady state precession (3-D FISP) T1-weighted imaging after gadolinium enhancement and compared the quality of the images of both the HASTE and 3-D FISP MRU technique in terms of their depiction of the dilated pelvocalyceal system, and the level, type, and causes of obstruction. In terms of anatomical depiction of the pelvocalyceal system (p=0.002) and the causes of obstruction (p=0.003). T1-weighted MRU using 3D-FISP was significantly better than T2-weighted MRU using the HASTE sequence. Regarding level of obstruction, T2-weighted MRU using the HASTE sequence and contrast enhanced T1-weighted MRU using 3D-FISP showed an accuracy of 76% (19/25) and 84% (21/25), respectively. In terms of type of obstruction, the accuracy of T2-weighted MRU and T1-weighted CEMRU was 72% (18/25) and 88% (22/25), respectively. T2-weighted MRU and Ta-weighted CEMRU provided both anatomical information and that relating to impaired renal function. The two modelities played a complementary role and their use could decrease the unnecessary use of invasive diagnostic examination for the evaluation of obstructive uropathy

  17. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Science.gov (United States)

    Huang, Meiyan; Yang, Wei; Wu, Yao; Jiang, Jun; Gao, Yang; Chen, Yang; Feng, Qianjin; Chen, Wufan; Lu, Zhentai

    2014-01-01

    This study aims to develop content-based image retrieval (CBIR) system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR) images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW) model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML) is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor). Using the BoVW model with partition learning, the mean average precision (mAP) of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  18. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Directory of Open Access Journals (Sweden)

    Meiyan Huang

    Full Text Available This study aims to develop content-based image retrieval (CBIR system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor. Using the BoVW model with partition learning, the mean average precision (mAP of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  19. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  20. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    International Nuclear Information System (INIS)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H.; Walter, Oliver; Gieseke, Juergen

    2007-01-01

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  1. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Walter, Oliver [Leibniz-Institute for Science Education, Kiel (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Hamburg (Germany)

    2007-05-15

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  2. SU-D-303-03: Impact of Uncertainty in T1 Measurements On Quantification of Dynamic Contrast Enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, M; Cao, Y [The University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: Quantification of dynamic contrast enhanced (DCE) MRI requires native longitudinal relaxation time (T1) measurement. This study aimed to assess uncertainty in T1 measurements using two different methods. Methods and Materials: Brain MRI scans were performed on a 3T scanner in 9 patients who had low grade/benign tumors and partial brain radiotherapy without chemotherapy at pre-RT, week-3 during RT (wk-3), end-RT, and 1, 6 and 18 months after RT. T1-weighted images were acquired using gradient echo sequences with 1) 2 different flip angles (50 and 150), and 2) 5 variable TRs (100–2000ms). After creating quantitative T1 maps, average T1 was calculated in regions of interest (ROI), which were distant from tumors and received a total of accumulated radiation doses < 5 Gy at wk-3. ROIs included left and right normal Putamen and Thalamus (gray matter: GM), and frontal and parietal white matter (WM). Since there were no significant or even a trend of T1 changes from pre-RT to wk-3 in these ROIs, a relative repeatability coefficient (RC) of T1 as a measure of uncertainty was estimated in each ROI using the data pre-RT and at wk-3. The individual T1 changes at later time points were evaluated compared to the estimated RCs. Results: The 2-flip angle method produced small RCs in GM (9.7–11.7%) but large RCs in WM (12.2–13.6%) compared to the saturation-recovery (SR) method (11.0–17.7% for GM and 7.5–11.2% for WM). More than 81% of individual T1 changes were within T1 uncertainty ranges defined by RCs. Conclusion: Our study suggests that the impact of T1 uncertainty on physiological parameters derived from DCE MRI is not negligible. A short scan with 2 flip angles is able to achieve repeatability of T1 estimates similar to a long scan with 5 different TRs, and is desirable to be integrated in the DCE protocol. Present study was supported by National Institute of Health (NIH) under grant numbers; UO1 CA183848 and RO1 NS064973.

  3. Fat-suppressed MRI of musculoskeletal infection: fast T2-weighted techniques versus gadolinium-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Miller, T.T.; Randolph, D.A. Jr.; Staron, R.B.; Feldman, F.; Cushin, S.

    1997-01-01

    Purpose. To investigate gadolinium's role in imaging musculoskeletal infection by comparing the conspicuity and extent of inflammatory changes demonstrated on gadolinium-enhanced fat-suppressed T1-weighted images versus fat-suppressed fast T2-weighted sequences. Design. Eighteen patients with infection were imaged in a 1.5-T unit, using frequency-selective and/or inversion recovery fat-suppressed fast T2-weighted images (T2WI) and gadolinium-enhanced frequency-selective fat-suppressed T1-weighted images (T1WI). Thirty-four imaging planes with both a fat-suppressed gadolinium-enhanced T1-weighted sequence and a fat-suppressed T2-weighted sequence were obtained. Comparison of the extent and conspicuity of signal intensity changes was made for both bone and soft tissue in each plane. Results. In bone, inflammatory change was equal in extent and conspicuity on fat-suppressed T2WI and fat-suppressed T1WI with gadolinium in 19 planes, more extensive or conspicuous on T2WI in three planes, and less so on T2WI in two planes. Marrow was normal on all three sequences in 10 cases. In soft tissue, inflammatory change was seen equally well in 20 instances, more extensively or conspicuously on the T2WI in 11 instances, and less so on T2WI in 2 instances. One case had no soft tissue involvement on any of the sequences. Five abscesses and three joint effusions were present, all more conspicuously delineated from surrounding inflammatory change on the fat-saturated T1WI with gadolinium. The average imaging time for the fat-saturated T1WI with gadolinium was 6.75 min, while that of the T2-weighted sequences was 5.75 min. Conclusion. Routine use of gadolinium is not warranted. Instead, gadolinium should be reserved for clinically suspected infection in or around a joint, and in cases refractory to medical or surgical treatment due to possible abscess formation. (orig.)

  4. Dynamic contrast-enhanced MRI in patients with luminal Crohn's disease

    International Nuclear Information System (INIS)

    Ziech, M.L.W.; Lavini, C.; Caan, M.W.A.; Nio, C.Y.; Stokkers, P.C.F.; Bipat, S.; Ponsioen, C.Y.; Nederveen, A.J.; Stoker, J.

    2012-01-01

    Objectives: To prospectively assess dynamic contrast-enhanced (DCE-)MRI as compared to conventional sequences in patients with luminal Crohn's disease. Methods: Patients with Crohn's disease undergoing MRI and ileocolonoscopy within 1 month had DCE-MRI (3T) during intravenous contrast injection of gadobutrol, single shot fast spin echo sequence and 3D T1-weighted spoiled gradient echo sequence, a dynamic coronal 3D T1-weighted fast spoiled gradient were performed before and after gadobutrol. Maximum enhancement (ME) and initial slope of increase (ISI) were calculated for four colon segments (ascending colon + coecum, transverse colon, descending colon + sigmoid, rectum) and (neo)terminal ileum. C-reactive protein (CRP), Crohn's disease activity index (CDAI), per patient and per segment Crohn's disease endoscopic index of severity (CDEIS) and disease duration were determined. Mean values of the (DCE-)MRI parameters in each segment from each patient were compared between four disease activity groups (normal mucosa, non-ulcerative lesions, mild ulcerative and severe ulcerative disease) with Mann–Whitney test with Bonferroni adjustment. Spearman correlation coefficients were calculated for continuous variables. Results: Thirty-three patients were included (mean age 37 years; 23 females, median CDEIS 4.4). ME and ISI correlated weakly with segmental CDEIS (r = 0.485 and r = 0.206) and ME per patient correlated moderately with CDEIS (r = 0.551). ME was significantly higher in segments with mild (0.378) or severe (0.388) ulcerative disease compared to normal mucosa (0.304) (p < 0.001). No ulcerations were identified at conventional sequences. ME correlated with disease duration in diseased segments (r = 0.492), not with CDAI and CRP. Conclusions: DCE-MRI can be used as a method for detecting Crohn's disease ulcerative lesions.

  5. Hemodynamic analysis of bladder tumors using T1-dynamic contrast-enhanced fast spin-echo MRI

    International Nuclear Information System (INIS)

    Kanazawa, Yuki; Miyati, Tosiaki; Sato, Osamu

    2012-01-01

    Objectives: To evaluate the hemodynamics of bladder tumors, we developed a method to calculate change in R 1 value (ΔR 1 ) from T 1 -dynamic contrast-enhanced fast spin-echo magnetic resonance imaging (T 1 DCE-FSE-MRI). Materials and methods: On a 1.5-T MR system, T 1 DCE-FSE-MRI was performed. This study was applied to 12 patients with urinary bladder tumor, i.e. urothelial carcinoma. We compared ΔR 1 –time and ΔSI–time between a peak in the ΔR 1 –time and ΔSI–time curve occurred during the first pass within 60 s. Next, we assessed the slope of increase for 180 s after CA injection (Slope 0–180 ). Results: The mean slope of the first pass was significantly higher for bladder tumors on both the ΔR 1 –time and the ΔSI–time curve compared with normal bladder walls. Moreover, a significant difference was apparent between bladder tumors and normal bladder walls on the mean Slope 0–180 in the ΔR 1 -time curve. However, no significant difference in the mean Slope 0–180 was observed on the ΔSI-time curve between bladder tumors and normal bladder walls. Conclusion: T 1 DCE-FSE-MRI offers three advantages: quantitative analysis; high-quality (i.e., artifact-free) images; and high temporal resolution even for SE images. Use of ΔR 1 analysis with T 1 DCE-FSE-MRI allows more detailed information on the hemodynamics of bladder tumors to be obtained and assists in differentiation between bladder tumors and the normal bladder wall.

  6. Can pre-operative contrast-enhanced dynamic MR imaging for prostate cancer predict microvessel density in prostatectomy specimens?

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Department of Diagnostic Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076, Tuebingen (Germany); Merkle, Jonas; Kaick, Gerhard van [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Grobholz, Rainer [Department of Pathology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Jaeger, Tim; Michel, Maurice Stephan [Department of Urology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Werner, Axel; Rabe, Jan [Department of Diagnostic Radiology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany)

    2004-02-01

    The aim of this study was to correlate quantitative dynamic contrast-enhanced MRI (DCE MRI) parameters with microvessel density (MVD) in prostate carcinoma. Twenty-eight patients with biopsy-proven prostate carcinoma were examined by endorectal MRI including multiplanar T2- and T1-weighted spin-echo and dynamic T1-weighted turbo-FLASH MRI during and after intravenous Gd-DTPA administration. Microvessels were stained on surgical specimens using a CD31 monoclonal antibody. The MVD was quantified in hot spots by counting (MVC) and determining the area fraction by morphometry (MVAF). The DCE MRI data were analyzed using an open pharmacokinetic two-compartment model. In corresponding anatomic locations the time shift ({delta}t) between the beginning of signal enhancement of cancer and adjacent normal prostatic tissue, the degree of contrast enhancement and the contrast exchange rate constant (k{sub 21}) were calculated. The MVC and MVAF were elevated in carcinoma (p<0.001 and p=0.002, respectively) and correlated to k{sub 21} (r=0.62, p<0.001 and r=0.80, p<0.001, respectively). k{sub 21}-values of carcinoma were significantly higher compared with normal peripheral but not central zone tissue. {delta}t was longer in high compared with low-grade tumors (p=0.025). The DCE MRI can provide important information about individual MVD in prostate cancer, which may be helpful for guiding biopsy and assessing individual prognosis. (orig.)

  7. Dynamic contrast-enhanced magnetic resonance imaging of articular and extraarticular synovial structures of the hands in patients with psoriatic arthritis

    DEFF Research Database (Denmark)

    Cimmino, Marco Amedeo; Barbieri, Francesca; Boesen, Mikael

    2012-01-01

    Dynamic, contrast-enhanced magnetic resonance imaging (DCE-MRI), the quantification of enhancement within the synovial membrane and bone by extracting curves using fast T1-weighted sequences during intravenous administration of contrast agent, evaluates synovitis and bone marrow edema in psoriati...... arthritis (PsA). In this pilot study, we looked at possible differences between joint synovitis and tenosynovitis in PsA as compared with rheumatoid arthritis (RA)....

  8. Dynamic contrast-enhanced MRI in patients with luminal Crohn's disease

    NARCIS (Netherlands)

    Ziech, M. L. W.; Lavini, C.; Caan, M. W. A.; Nio, C. Y.; Stokkers, P. C. F.; Bipat, S.; Ponsioen, C. Y.; Nederveen, A. J.; Stoker, J.

    2012-01-01

    Objectives: To prospectively assess dynamic contrast-enhanced (DCE-)MRI as compared to conventional sequences in patients with luminal Crohn's disease. Methods: Patients with Crohn's disease undergoing MRI and ileocolonoscopy within 1 month had DCE-MRI (3T) during intravenous contrast injection of

  9. Contrast-enhanced dynamic and diffusion-weighted magnetic resonance imaging at 3.0 T to assess early-stage nasopharyngeal carcinoma.

    Science.gov (United States)

    Ni, Liangping; Liu, Ying

    2018-04-01

    The present study aimed to assess early-stage nasopharyngeal carcinoma (NPC) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) at 3.0 T. A total of 44 patients newly diagnosed with NPC were included in the present study. All patients underwent MR examination at 3.0 T using DCE-MRI and DWI. The volume transfer constant ( K trans ), flux rate constant between extravascular extracellular space and plasma ( K ep ), the volume of extravascular extracellular space per unit volume of tissue ( V e ) and the apparent diffusion coefficient (ADC) of tumours were investigated. Furthermore, the correlation between clinical stages and ADC value and K trans were analysed. The diagnostic accuracy of K trans and ADC were estimated using receiver operating characteristic curves. NPC stage correlated positively with K trans and negatively with ADC values. Additionally, tumour K trans negatively correlated with ADC value. The sensitivity and accuracy of combined K trans and ADC in distinguishing between stage II and stage III and stage III and IV were higher than the values of either measurement used separately. The present study suggested that K trans and ADC derived from DCE-MRI and DWI may be useful to detect stage early NPC accurately. K trans and ADC in combination were superior than either alone.

  10. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  11. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  12. Contrast-enhanced MR imaging of metastatic brain tumor at 3 Tesla. Utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence

    International Nuclear Information System (INIS)

    Komada, Tomohiro; Naganawa, Shinji; Ogawa, Hiroshi

    2008-01-01

    We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T 1 -weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T 1 -weighted spin echo (2D-SE) imaging at 3 T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P 1 -weighted imaging. (author)

  13. The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides.

    Science.gov (United States)

    Cao, Limin; Li, Binbin; Yi, Peiwei; Zhang, Hailu; Dai, Jianwu; Tan, Bo; Deng, Zongwu

    2014-04-01

    Three Gd-DOTA-peptide complexes with different peptide sequence are synthesized and used as T1 contrast agent to label human mesenchymal stem cells (hMSCs) for magnetic resonance imaging study. The peptides include a universal cell penetrating peptide TAT, a linear MSC-specific peptide EM7, and a cyclic MSC-specific peptide CC9. A significant difference in labeling efficacy is observed between the Gd-DOTA-peptides as well as a control Dotarem. All Gd-DOTA-peptides as well as Dotarem induce significant increase in T1 relaxation rate which is in favor of T1-weighted MR imaging. Gd-DOTA-CC9 yields the maximum labeling efficacy but poor T1 contrast enhancement. Gd-DOTA-EM7 yields the minimum labeling efficacy but better T1 contrast enhancement. Gd-DOTA-TAT yields a similar labeling efficacy as Gd-DOTA-CC9 and similar T1 contrast enhancement as Gd-DOTA-EM7. The underlying mechanism that governs T1 contrast enhancement effect is discussed. Our results suggest that T1 contrast enhancement induced by Gd-DOTA-peptides depends not only on the introduced cellular Gd content, but more importantly on the effect that Gd-DOTA-peptides exert on the T1-relaxation and T2-relaxation processes/rates. Both T1 and particularly T2 relaxation rate have to be taken into account to interpret T1 contrast enhancement. In addition, the interpretation has to be based on cellular instead of aqueous longitudinal and transverse relaxivities of Gd-DOTA-peptides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    Energy Technology Data Exchange (ETDEWEB)

    Larribe, Maud [Hopital La Conception, Service d' imagerie medicale, Marseille (France); Hopital Sainte Marguerite, Service d' imagerie medicale, Marseille (France); Gay, Andre [Hopital La Conception, Service de chirurgie de la main, Marseille (France); Freire, Veronique [Centre hospitalier de l' Universite de Montreal, Department of Radiology, Notre-Dame Hospital, Montreal, QC (Canada); Bouvier, Corinne [Hopital La Timone, Service d' anatomopathologie, Marseille (France); Chagnaud, Christophe; Souteyrand, Philippe [Hopital La Conception, Service d' imagerie medicale, Marseille (France)

    2014-12-15

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  15. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    International Nuclear Information System (INIS)

    Larribe, Maud; Gay, Andre; Freire, Veronique; Bouvier, Corinne; Chagnaud, Christophe; Souteyrand, Philippe

    2014-01-01

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  16. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  17. The impact of reliable prebolus T 1 measurements or a fixed T 1 value in the assessment of glioma patients with dynamic contrast enhancing MRI.

    Science.gov (United States)

    Tietze, Anna; Mouridsen, Kim; Mikkelsen, Irene Klærke

    2015-06-01

    Accurate quantification of hemodynamic parameters using dynamic contrast enhanced (DCE) MRI requires a measurement of tissue T 1 prior to contrast injection (T 1). We evaluate (i) T 1 estimation using the variable flip angle (VFA) and the saturation recovery (SR) techniques and (ii) investigate if accurate estimation of DCE parameters outperform a time-saving approach with a predefined T 1 value when differentiating high- from low-grade gliomas. The accuracy and precision of T 1 measurements, acquired by VFA and SR, were investigated by computer simulations and in glioma patients using an equivalence test (p > 0.05 showing significant difference). The permeability measure, K trans, cerebral blood flow (CBF), and - volume, V p, were calculated in 42 glioma patients, using fixed T 1 of 1500 ms or an individual T 1 measurement, using SR. The areas under the receiver operating characteristic curves (AUCs) were used as measures for accuracy to differentiate tumor grade. The T 1 values obtained by VFA showed larger variation compared to those obtained using SR both in the digital phantom and the human data (p > 0.05). Although a fixed T 1 introduced a bias into the DCE calculation, this had only minor impact on the accuracy differentiating high-grade from low-grade gliomas, (AUCfix = 0.906 and AUCind = 0.884 for K trans; AUCfix = 0.863 and AUCind = 0.856 for V p; p for AUC comparison > 0.05). T 1 measurements by VFA were less precise, and the SR method is preferable, when accurate parameter estimation is required. Semiquantitative DCE values, based on predefined T 1 values, were sufficient to perform tumor grading in our study.

  18. A Prospective Evaluation of T2-Weighted First-Pass Perfusion MR Imaging In Diagnosing Breast Neoplasms

    Institute of Scientific and Technical Information of China (English)

    XiaoJuanUu; RenyouZhai; TaoJiang; LiWang

    2004-01-01

    OBJECTIVE To compare the results from breast cancer patients who undergo T2-weighted first-pass perfusion imaging after dynamic contrast-enhanced T1-weighted imaging during the same examination,and to evaluate if T2-weighted imaging can provide additional diagnostic information over that obtained with Tl-weiahted imaaina.METHODS Twenty-nine patients with breast lesions verified by pathology (benign 12, malignant 17) underwent MR imaging with dynamic contrast-enhanced Tl-weighted imaging of the entire breasts,immediately followed by 6-sections of T2-weighted first-pass perfusion imaging of the lesions. The diagnostic indices were acquired by individual 3D Tl-weighted enhancement rate criterion and the T2 signalintensity loss rate criterion. The sensitivity and specificity were calculated and the 2 methods were compared.RESULTS With the dynamic contrast-enhanced T1-weighted imaging there was a significant differences breast lesions (t=2.563, P=0.016)overlap between the signal intensitybetween the benign and malignant However we found a considerable increase in the carcinomas and thatin the benign lesions, for a sensitivity of 94% and a specificity of 25%.With T2-weighted first-pass perfusion imaging, there was a very significant difference between the benign and malignant breast lesions(t=4.777,P<0.001), and the overlap between the signal intensity decrease in the carcinomas and that of the benign lesions on the T2-weighted images was less pronounced than the overlap in the T1-weighted images, for a sensitivity of 88% and a specificity of 75%.CONCLUSION T2-weighted first-pass perfusion imaging may help differentiate between benign and malignant breast lesions with a higher level of specificity. The combination of T1-weighted and T2-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

  19. Prediction of prostate cancer extracapsular extension with high spatial resolution dynamic contrast-enhanced 3-T MRI

    International Nuclear Information System (INIS)

    Bloch, B.N.; Genega, Elizabeth M.; Costa, Daniel N.; Pedrosa, Ivan; Rofsky, Neil M.; Smith, Martin P.; Kressel, Herbert Y.; Ngo, Long; Sanda, Martin G.; DeWolf, William C.

    2012-01-01

    To assess the value of dynamic contrast-enhanced (DCE) combined with T2-weighted (T2W) endorectal coil (ERC) magnetic resonance imaging (MRI) at 3 T for determining extracapsular extension (ECE) of prostate cancer. In this IRB-approved study, ERC 3-T MRI of the prostate was performed in 108 patients before radical prostatectomy. T2W fast spin-echo and DCE 3D gradient echo images were acquired. The interpretations of readers with varied experience were analysed. MRI-based staging results were compared with radical prostatectomy histology. Descriptive statistics were generated for prediction of ECE and staging accuracies were determined by the area under the receiver-operating characteristic curve. The overall sensitivity, specificity, positive predictive value and negative predictive value for ECE were 75 %, 92 %, 79 % and 91 %, respectively. Diagnostic accuracy for staging was 86 %, 80 % and 91 % for all readers, experienced and less experienced readers, respectively. ERC 3-T MRI of the prostate combining DCE and T2W imaging is an accurate pretherapeutic staging tool for assessment of ECE in clinical practice across varying levels of reader experience. (orig.)

  20. Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Roque, Andreia; Ramalho, Miguel; AlObaidy, Mamdoh; Heredia, Vasco; Burke, Lauren M.; De Campos, Rafael O.P.; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2014-10-15

    Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. To compare the image quality of three different post-contrast T1-weighted imaging techniques - standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE) - acquired in pediatric patients younger than 5 years of age. Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential. (orig.)

  1. Dynamic contrast-enhanced, extremity-dedicated MRI identifies synovitis changes in the follow-up of rheumatoid arthritis patients treated with rituximab

    DEFF Research Database (Denmark)

    Cimmino, Marco A; Parodi, Massimiliano; Zampogna, Giuseppe

    2014-01-01

    according to the 1987 ACR criteria were treated with a single course of RTX (2 infusions of 1000 mg, 15 days apart). MRI of the dominant hand was performed with a 0.2T extremity-dedicated machine using pre and post contrast T1 weighted SE, turbo 3D, and STIR sequences at baseline, and after 4 and 24 weeks....... MRI was analysed using the OMERACT-RAMRIS score and the dynamic contrast-enhanced (DCE-MRI) technique for wrist synovitis, which calculates the enhancement ratio as both rate of early enhancement (REE) and relative enhancement (RE). The corresponding ME and IRE parameters were calculated also through...

  2. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  3. Measurement of brain oxygenation changes using dynamic T1-weighted imaging

    DEFF Research Database (Denmark)

    Haddock, Bryan; Larsson, Henrik B W; Hansen, Adam E

    2013-01-01

    Magnetic resonance imaging (MRI) has proven useful in evaluating oxygenation in several types of tissue and blood. This study evaluates brain tissue oxygenation changes between normoxia and hyperoxia in healthy subjects using dynamic T1 and T2*-weighted imaging sequences. The change in FiO2 induced...... by hyperoxia caused a significant decrease in T1. A model to determine changes in tissue oxygen tension from the T1-weighted MRI signal is presented based on previous findings that T1 is sensitive to oxygen tension whereas T2* is sensitive to blood saturation. The two sequences produce results with different...... regional and temporal dynamics. These differences combined with results from simulations of the T1 signal intensities, indicate an increase in extravascular oxygen tension during hyperoxia. This study concludes that T1 and T2* responses to FiO2 serve as independent biomarkers of oxygen physiology...

  4. VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver

    International Nuclear Information System (INIS)

    Dobritz, M.; Radkow, T.; Bautz, W.; Fellner, F.A.; Nittka, M.

    2002-01-01

    Purpose: The VIBE (volume interpolated breath-hold examination) sequence in combination with parallel acquisition technique (iPAT: integrated parallel acquisition technique) allows dynamic contrast-enhanced MRI of the liver with high temporal and spatial resolution. The aim of this study was to obtain first clinical experience with this technique for the detection and characterization of focal liver lesions. Materials and Methods: We examined 10 consecutive patients using a 1.5 T MR system (gradient field strength 30 mT/m) with a phased-array coil combination. Following sequences- were acquired: T 2 -w TSE and T 1 -w FLASH, after administration of gadolinium, 6 VIBE sequences with iPAT (TR/TE/matrix/partition thickness/time of acquisition: 6.2 ms/ 3.2 ms/256 x 192/4 mm/13 s), as well as T 1 -weighted FLASH with fat saturation. Two observers evaluated the different sequences concerning the number of lesions and their dignity. Following lesions were found: hepatocellular carcinoma (5 patients), hemangioma (2), metastasis (1), cyst (1), adenoma (1). Results: The VIBE sequences were superior for the detection of lesions with arterial hyperperfusion with a total of 33 focal lesions. 21 lesions were found with T 2 -w TSE and 20 with plain T 1 -weighted FLASH. Diagnostic accuracy increased with the VIBE sequence in comparison to the other sequences. Conclusion: VIBE with iPAT allows MR imaging of the liver with high spatial and temporal resolution providing dynamic contrast-enhanced information about the whole liver. This may lead to improved detection of liver lesions, especially hepatocellular carcinoma. (orig.) [de

  5. T2-weighted vs. intrathecal contrast-enhanced MR cisternography in the evaluation of CSF rhinorrhea

    International Nuclear Information System (INIS)

    Ecin, Gaye; Oner, A. Yusuf; Tokgoz, Nil; Ucar, Murat; Tali, Turgut; Aykol, Sukru

    2013-01-01

    Background: Endoscopic surgical approach is being more widely used in the treatment of cerebrospinal fluid (CSF) rhinorrhea. Accurate localization of CSF fistulas prior to surgery is essential in increasing the success of dural repair and in decreasing negative or recurrent explorations. Purpose: To evaluate and compare intrathecal contrast medium-enhanced magnetic resonance cisternography (CEMRC) with T2-weighted MR cisternography (T2MRC) in identifying the presence and site of CSF rhinorrhea. Material and Methods: Sixty patients with suspected CSF rhinorrhea underwent MR cisternography including intrathecally enhanced fat-suppressed T1WI in three orthogonal planes and T2WI in the coronal plane. Both set of images were reviewed by two blinded radiologists for the presence and location of CSF leakage. Imaging data were compared with surgical findings and/or beta-2 transferrin testing. Results: With surgery proven CSF leakage in 20 instances as reference, CEMRC detected 18 (90%), whereas T2MRC reported only 13 (65%) correctly. Overall, sensitivity, specificity, positive predictive value, and negative predictive value in detecting CSF fistulas were 92%, 80%, 76%, and 93% for CEMRC, and 56%, 77%, 64%, and 71% for T2MRC, respectively. Conclusion: The minimally invasive CEMRC is an effective method with higher sensitivity and specificity than T2MRC in the evaluation of CSF fistulas

  6. Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Gemeinhardt, O.; Prochnow, D.; Taupitz, M.; Hamm, B.; Beyersdorff, D.; Luedemann, L.; Abramjuk, C.

    2005-01-01

    Purpose: to differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. Material and methods: tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. Results: axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm3. In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420% (p<0.001) and 424% (p<0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. Conclusion: the results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model. (orig.)

  7. Dynamic contrast-enhanced MRI of the prostate. Comparison of two different post-processing algorithms

    International Nuclear Information System (INIS)

    Beyersdorff, Dirk; Franiel, T.; Luedemann, L.; Dietz, E.; Galler, D.; Marchot, P.

    2011-01-01

    Purpose: To evaluate the usefulness of a commercially available post-processing software tool for detecting prostate cancer on dynamic contrast-enhanced magnetic resonance imaging (MRI) and to compare the results to those obtained with a custom-made post-processing algorithm already tested under clinical conditions. Materials and Methods: Forty-eight patients with proven prostate cancer were examined by standard MRI supplemented by dynamic contrast-enhanced dual susceptibility contrast (DCE-DSC) MRI prior to prostatectomy. A custom-made post-processing algorithm was used to analyze the MRI data sets and the results were compared to those obtained using a post-processing algorithm from Invivo Corporation (Dyna CAD for Prostate) applied to dynamic T 1-weighted images. Histology was used as the gold standard. Results: The sensitivity for prostate cancer detection was 78 % for the custom-made algorithm and 60 % for the commercial algorithm and the specificity was 79 % and 82 %, respectively. The accuracy was 79 % for our algorithm and 77.5 % for the commercial software tool. The chi-square test (McNemar-Bowker test) yielded no significant differences between the two tools (p = 0.06). Conclusion: The two investigated post-processing algorithms did not differ in terms of prostate cancer detection. The commercially available software tool allows reliable and fast analysis of dynamic contrast-enhanced MRI for the detection of prostate cancer. (orig.)

  8. Dynamic contrast-enhanced MRI in patients with luminal Crohn's disease

    Energy Technology Data Exchange (ETDEWEB)

    Ziech, M.L.W., E-mail: m.l.ziech@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Lavini, C., E-mail: c.lavini@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Caan, M.W.A., E-mail: m.w.a.caan@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Nio, C.Y., E-mail: C.Y.Nio@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Stokkers, P.C.F., E-mail: p.stokkers@slaz.nl [Academic Medical Center, Department of Gastroenterology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Sint Lucas Andreas Ziekenhuis, Department of Gastroenterology, Jan Tooropstraat 164, 1061 AE, Amsterdam (Netherlands); Bipat, S., E-mail: S.Bipat@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Ponsioen, C.Y., E-mail: c.y.ponsioen@amc.uva.nl [Academic Medical Center, Department of Gastroenterology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Nederveen, A.J., E-mail: a.j.nederveen@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Stoker, J., E-mail: j.stoker@amc.uva.nl [Academic Medical Center, Department of Radiology, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands)

    2012-11-15

    Objectives: To prospectively assess dynamic contrast-enhanced (DCE-)MRI as compared to conventional sequences in patients with luminal Crohn's disease. Methods: Patients with Crohn's disease undergoing MRI and ileocolonoscopy within 1 month had DCE-MRI (3T) during intravenous contrast injection of gadobutrol, single shot fast spin echo sequence and 3D T1-weighted spoiled gradient echo sequence, a dynamic coronal 3D T1-weighted fast spoiled gradient were performed before and after gadobutrol. Maximum enhancement (ME) and initial slope of increase (ISI) were calculated for four colon segments (ascending colon + coecum, transverse colon, descending colon + sigmoid, rectum) and (neo)terminal ileum. C-reactive protein (CRP), Crohn's disease activity index (CDAI), per patient and per segment Crohn's disease endoscopic index of severity (CDEIS) and disease duration were determined. Mean values of the (DCE-)MRI parameters in each segment from each patient were compared between four disease activity groups (normal mucosa, non-ulcerative lesions, mild ulcerative and severe ulcerative disease) with Mann-Whitney test with Bonferroni adjustment. Spearman correlation coefficients were calculated for continuous variables. Results: Thirty-three patients were included (mean age 37 years; 23 females, median CDEIS 4.4). ME and ISI correlated weakly with segmental CDEIS (r = 0.485 and r = 0.206) and ME per patient correlated moderately with CDEIS (r = 0.551). ME was significantly higher in segments with mild (0.378) or severe (0.388) ulcerative disease compared to normal mucosa (0.304) (p < 0.001). No ulcerations were identified at conventional sequences. ME correlated with disease duration in diseased segments (r = 0.492), not with CDAI and CRP. Conclusions: DCE-MRI can be used as a method for detecting Crohn's disease ulcerative lesions.

  9. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    International Nuclear Information System (INIS)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon

    1997-01-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change

  10. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon [Hanyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change.

  11. Added value of diffusion-weighted MRI in detection of cervical cancer recurrence: comparison with morphologic and dynamic contrast-enhanced MRI sequences.

    Science.gov (United States)

    Lucas, Rita; Lopes Dias, João; Cunha, Teresa Margarida

    2015-01-01

    We aimed to evaluate the added value of diffusion-weighted imaging (DWI) to standard magnetic resonance imaging (MRI) for detecting post-treatment cervical cancer recurrence. The detection accuracy of T2-weighted (T2W) images was compared with that of T2W MRI combined with either dynamic contrast-enhanced (DCE) MRI or DWI. Thirty-eight women with clinically suspected uterine cervical cancer recurrence more than six months after treatment completion were examined with 1.5 Tesla MRI including T2W, DCE, and DWI sequences. Disease was confirmed histologically and correlated with MRI findings. The diagnostic performance of T2W imaging and its combination with either DCE or DWI were analyzed. Sensitivity, positive predictive value, and accuracy were calculated. Thirty-six women had histologically proven recurrence. The accuracy for recurrence detection was 80% with T2W/DCE MRI and 92.1% with T2W/DWI. The addition of DCE sequences did not significantly improve the diagnostic ability of T2W imaging, and this sequence combination misclassified two patients as falsely positive and seven as falsely negative. The T2W/DWI combination revealed a positive predictive value of 100% and only three false negatives. The addition of DWI to T2W sequences considerably improved the diagnostic ability of MRI. Our results support the inclusion of DWI in the initial MRI protocol for the detection of cervical cancer recurrence, leaving DCE sequences as an option for uncertain cases.

  12. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  13. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  14. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Espinosa, Norman [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2017-08-15

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  15. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    International Nuclear Information System (INIS)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja; Espinosa, Norman

    2017-01-01

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  16. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  17. Evaluation of dynamic contrast-enhanced T1-weighted perfusion MRI in the differentiation of tumor recurrence from radiation necrosis

    DEFF Research Database (Denmark)

    Larsen, Anne Vibeke Andrée; Simonsen, Helle J; Law, Ian

    2013-01-01

    INTRODUCTION: To investigate if perfusion measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to differentiate radiation necrosis from tumor recurrence in patients with high-grade glioma. METHODS: The study was approved by the institutional review board...... to measure cerebral blood volume (CBV), blood-brain barrier (BBB) permeability and cerebral blood flow (CBF). Subjects also underwent FDG-PET and lesions were classified as either metabolically active or inactive. Follow-up clinical MRI and lesion histology in case of additional tissue resection was used...... to determine whether lesions were regressing or progressing. RESULTS: Fourteen enhancing lesions could be classified as progressing (11) or regressing (three). An empirical threshold of 2.0 ml/100 g for CBV allowed detection of regressing lesions with a sensitivity of 100 % and specificity of 100 %. FDG-PET...

  18. Hilar branching anatomy of living adult liver donors: comparison of T2-MR cholangiography and contrast enhanced T1-MR cholangiography in terms of diagnostic utility

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Kim, Myeong Jin; Kim, Kyung Sik; Kim, Joo Hee; Oh, Young Taik; Kim, Jin Yong; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2004-01-01

    To compare T2-weighted MR cholangiography (T2-MRC) and contrast-enhanced T1-weighted MRC (enhanced T1-MRC) in the assessment of biliary anatomy in donor candidates for living related liver transplantation (LRLT). Thirty-three potential donors underwent MR examination for preoperative evaluation. Using the single-shot half-Fourier RARE sequence, T2-weighted single-section and coronal images were obtained, and enhanced T1-MRC was performed, using 3D GRE sequences after the administration of mangafodifir trisodium. To assess the hilar ductal branching pattern and determine diagnostic confidence, two reviewers first evaluated the unpaired T2-MRC and enhanced T1-MRC images, and then paired T2-MRC and enhanced T1-MRC images together. In particular, in 12 cases in which direct cholangiographys were performed, the feasibility of single duct-to-duct anastomosis was assessed using the unpaired and the paired sets sequentially. The reviewers, confidence tended to be higher for enhanced T1-MRC than T2-MRC, but the difference was not statistically significant. For both reviewers, confidence was significantly higher for the paired set than for T2- or enhanced T1-MRC alone (p<0.001). The types of biliary anatomy determined in the paired set matched the consensus reading in 33 (100%) and 30 cases(91%) assessed by reviewer 1 and 2, respectively. The separate interpretation of T2- and enhanced T1-MRC findings matched the consensus interpretation in 30 (91%) and 28 cases (85%), respectively, assessed by reviewer 1, and 26 (79%) and 28 cases (85%), respectively, assessed by reviewer 2. The possibility of single anastomosis was accurately predicted in 91.6% of cases in T2-MRC, and 100% at enhanced T1-MRC and the combined set. In the evaluation of the biliary anatomy of potential donors for LRLT, the combined use of T2-MRC and enhanced T1-MRC may improve diagnostic confidence and decrease the occurrence of a non diagnostic or equivocal interpretation at T2-MRC alone

  19. Cerebral staging of lung cancer: is one single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence sufficient?

    Energy Technology Data Exchange (ETDEWEB)

    Ohana, Mickael; Jeung, Mi-Young; Roy, Catherine [Nouvel Hopital Civil-Hopitaux Universitaires de Strasbourg, Service de Radiologie B/Radiology Department, Strasbourg (France); Bazille, Gauthier [Clinique Saint Anne-Groupe Radiologique MIM, Strasbourg (France)

    2014-08-15

    Gadolinium-enhanced magnetic resonance imaging (MRI) is the gold standard for cerebral staging in thoracic oncology. We hypothesize that a minimalist examination, consisting of a single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence (CE 3D-GRE), would be sufficient for the cerebral staging of nonsymptomatic lung cancer patients. Seventy nonsymptomatic patients (50 % men; 62 years ± 10.2) referred for cerebral staging of a lung cancer were retrospectively included. All underwent a standard 3 T MRI examination with T1, FLAIR, T2* GRE, diffusion, and CE 3D-GRE sequences, for a total examination time of 20 min. The sole CE 3D-GRE (acquisition time: 6 min) was extracted and blindly interpreted by two radiologists in search of brain metastases. Hemorrhagic features of potential lesions and relevant incidental findings were also noted. Discrepant cases were reviewed by a third reader. The full MRI examination and follow-up studies were used as a reference to calculate sensitivity and specificity of the sole CE 3D-GRE. Thirty-eight point six percent (27 out of 70) of the patients had brain metastases. Performances and reader's agreement with the sole CE 3D-GRE sequence were excellent for the diagnosis of brain metastases (sensitivity = 96.3 %, specificity = 100 %, κ = 0.91) and incidental findings (sensitivity = 85.7 %, specificity = 100 %, κ = 0.62) but insufficient for the identification of hemorrhages within the metastases (sensitivity = 33.3 %, specificity = 85.7 %, κ = 0.47). In the specific case of lung cancer, cerebral staging in nonsymptomatic patients can be efficiently achieved with a minimalistic protocol consisting of a single CE 3D-GRE sequence, completed if positive with a T2* sequence for hemorrhagic assessment, thus halving appointment delays. (orig.)

  20. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S. [Univ. Hospital of Regensburg (Germany). Dept. of Diagnostic Radiology; Stamato, S. [Univ. of California, San Diego, CA (United States). Dept. of Radiology

    2002-07-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

  1. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S.; Stamato, S.

    2002-01-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage

  2. A wide variety of dynamic contrast-enhanced MR appearances of breast cancer: Pathologic correlation study

    International Nuclear Information System (INIS)

    Onishi, Masayuki; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2008-01-01

    Purpose: The aim of this study was to elucidate the characteristic magnetic resonance (MR) appearance of breast cancers, as well as, its variations and to investigate the pathology providing different patterns of dynamic-MR appearances. Materials and methods: Fifty-two women with cancer underwent mastectomy (52 tumors resected) and had MR imaging at our institution between April 2001 and March 2004. MR images of T1WI, T2WI, dynamic-MRI and contrast-enhanced T1WI were obtained and evaluated. Dynamic-MR images were correlated with pathological findings. Results: Common MR appearance of breast cancer was a focal mass either with irregular or spiculated margins with similar signal intensity on T1WI as and similar to higher signal intensity on T2WI compared to the normal mammary gland. On static contrast-enhanced T1WI, apparent enhancement was typically observed. On dynamic MRI, tumor-rim-enhancement on an early phase image and washout enhancement pattern on dynamic images, both characteristic for breast cancer, were observed, however, the prevalence of them was relatively low, which could be explained by the variation of histopathology among breast cancer nodules. Conclusion: In diagnosing breast masses on MRI, as well as the common and characteristic findings of breast cancer, the variations of MR findings and their underlying histopathology should also be considered

  3. Assessment of image display of contrast enhanced T1W images with fat suppression

    International Nuclear Information System (INIS)

    Miyazaki, Isao; Ishizaki, Keiko; Kobayashi, Kuninori; Katou, Masanobu

    2006-01-01

    The effects of imaging conditions and measures for their improvement were examined with regard to recognition of the effects of contrast on images when T 1 -weighted imaging with selective fat suppression was applied. Luminance at the target region was examined before and after contrast imaging using phantoms assuming pre- and post-imaging conditions. A clinical examination was performed on tumors revealed by breast examination, including those surrounded by mammary gland and by fat tissue. When fat suppression was used and imaging contrast was enhanced, the luminance level of fat tumors with the same structure as the prepared phantoms appeared to be high both before and after contrast imaging, and the effects of contrast were not distinguishable. This observation is attributable to the fact that the imaging conditions before and after contrast imaging were substantially different. To make a comparison between pre- and post-contrast images, it is considered necessary to perform imaging with fixed receiver gain and to apply the same imaging method for pre- and post-contrast images by adjusting post-contrast imaging conditions to those of pre-contrast imaging. (author)

  4. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Athyal, R. P.; Ismail, M.; Rudwan, M.; Khafajee, S.

    2009-01-01

    Full text: Tl-weighted fluid-attenuated inversion recovery (FLAIR) sequence is a relatively new pulse sequence for intracranial MR imaging. This study was performed to compare the image quality of Tl-weighted FLAIR with the Tl-weighted FSE sequence. Twenty patients with brain lesions underwent Tl-weighted fast spin-echo (FSE) and Tl-weighted FLAIR during the same imaging session. Four quantitative and three qualitative criteria were used to compare the two sequences after contrast. Two of four quantitative criteria pertained to lesion characteristics: lesion to white matter (WM) contrast-to-noise ratio (CNR) and lesion to cerebrospinal fluid (CSF) CNR, and two related to signals from normal tissue: grey matter to WM CNR and WM to CSF CNR. The three qualitative criteria were conspicuousness of the lesion, the presence of image artefacts and the overall image contrast. Both Tl-weighted FSE and FLAIR images were effective in demonstrating lesions. Image contrast was superior in Tl-weighted FLAIR images with significantly improved grey matter-WM CNRs and CSF-WM CNRs. The overall image contrast was judged to be superior on Tl-weighted FLAIR images compared with Tl-weighted FSE images by all neuroradiologists. Two of three reviewers considered that the FLAIR images had slightly increased imaging artefacts that, however, did not interfere with image interpretation. Tl-weighted FLAIR imaging provides improved lesion-to-background and grey to WM contrast-to-noise ratios. Superior conspicuity of lesions and overall image contrast is obtained in comparable acquisition times. These indicate an important role for Tl-weighted FLAIR in intracranial imaging and highlight its advantage over the more widely practiced Tl-weighted FSE sequence

  5. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  6. Mn-DPDP enhanced T1-weighted magnetic resonance cholangiography: usefulness in the diagnosis and roadmap for the treatment of intrahepatic choIedochoIithiasis

    International Nuclear Information System (INIS)

    Park, Mi Suk; Kim, Ki Whang; Yu, Jeong Sik; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Kim, Kyoung Won; Kim, Tae Kyoung; Ha, Hyun Kwon

    2004-01-01

    To assess the preliminary findings of Mn-enhanced T1-weighted MR cholangiography for the evaluation of intrahepatic choledocholithiasis. Seven patients with recurrent pyogenic cholangitis underwent conventional heavily T2-weighted and manganese-enhanced T1-weighted MR cholangiography. For the former, the two reviewers focused on intrahepatic ductal dilatation, calculi, and stricture; and for the latter, ductal enhancement. In seven patients, 13 diseased segments were depicted and intrahepatic bile ductal dilatation was present in all 13 of these in all seven patients. Calculi were present in eight segments in six patients, and stricture in four segments in three patients. Of the 13 diseased segmental ducts, six were seen at manganese-enhanced imaging to be filled with contrast material, suggesting a functioning bile duct. Combined T2-weighted and mangafodipir trisodium-enhanced T1-weighted MR cholangiography provides both anatomic detail and functional detail of the biliary system. Combined MR cholangiography is useful for the evaluation of intrahepatic choledocholithiasis, demonstrating the stricture and function of the segmental ducts involved

  7. Dynamic contrast-enhanced perfusion studies of the brain with snapshot FLASH

    International Nuclear Information System (INIS)

    Finelli, D.A.; Kiefer, B.; Deimling, M.; Loeffler, W.; Haase, A.; Schuierer, G.

    1989-01-01

    This paper discusses how MR imaging with Gd-DTPA can improve the diagnostic accuracy of brain examinations. Conventional T1-weighted spin-echo sequences have been most satisfactory for depicting lesion enhancement following Gd-DTPA administration, however, the ability to examine the blood pool and early biodistribution phases has been limited. A new ultrafast MR imaging technique called Snapshot FLASH allows one to acquire entire images in 125-900 msec, with strong T1- or T2-weighted contrast. With this imaging technique, one can observe differential perfusion to the gray matter, while matter, and brain lesions during the first seconds following Gd-DTPA administration

  8. An efficient sequence for fetal brain imaging at 3T with enhanced T1 contrast and motion robustness.

    Science.gov (United States)

    Ferrazzi, Giulio; Price, Anthony N; Teixeira, Rui Pedro A G; Cordero-Grande, Lucilio; Hutter, Jana; Gomes, Ana; Padormo, Francesco; Hughes, Emer; Schneider, Torben; Rutherford, Mary; Kuklisova Murgasova, Maria; Hajnal, Joseph V

    2018-07-01

    Ultrafast single-shot T 2 -weighted images are common practice in fetal MR exams. However, there is limited experience with fetal T 1 -weighted acquisitions. This study aims at establishing a robust framework that allows fetal T 1 -weighted scans to be routinely acquired in utero at 3T. A 2D gradient echo sequence with an adiabatic inversion was optimized to be robust to fetal motion and maternal breathing optimizing grey/white matter contrast at the same time. This was combined with slice to volume registration and super resolution methods to produce volumetric reconstructions. The sequence was tested on 22 fetuses. Optimized grey/white matter contrast and robustness to fetal motion and maternal breathing were achieved. Signal from cerebrospinal fluid (CSF) and amniotic fluid was nulled and 0.75 mm isotropic anatomical reconstructions of the fetal brain were obtained using slice-to-volume registration and super resolution techniques. Total acquisition time for a single stack was 56 s, all acquired during free breathing. Enhanced sensitivity to normal anatomy and pathology with respect to established methods is demonstrated. A direct comparison with a 3D spoiled gradient echo sequence and a controlled motion experiment run on an adult volunteer are also shown. This paper describes a robust framework to perform T 1 -weighted acquisitions and reconstructions of the fetal brain in utero. Magn Reson Med 80:137-146, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic

  9. Contrast-enhanced ultra-high-field liver MRI: A feasibility trial

    Energy Technology Data Exchange (ETDEWEB)

    Umutlu, Lale, E-mail: Lale.Umutlu@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Bitz, Andreas K.; Maderwald, Stefan; Orzada, Stephan; Kinner, Sonja; Kraff, Oliver; Brote, Irina; Ladd, Susanne C.; Schroeder, Tobias; Forsting, Michael; Antoch, Gerald; Ladd, Mark E. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Quick, Harald H. [Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Institute of Medical Physics, University Nuernberg-Erlangen (Germany); Lauenstein, Thomas C. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2013-05-15

    The aim of this study was to investigate the feasibility of dynamic contrast-enhanced 7 T MRI of the liver using an eight-channel radiofrequency (RF) transmit/receive body-coil. 16 healthy subjects were examined on a 7 T MR system utilizing a custom-built eight-channel RF body-coil suitable for RF-shimming. The following data were acquired: (1) steady state free precession imaging, (2) T2w turbo spin echo imaging, (3) T1w in and opposed-phase imaging, (4) T1w 3D FLASH images pre-contrast and in arterial, portal-venous and venous phase and (5) a fat-saturated pre- and post-contrast 2D FLASH sequence. Visual evaluation of (1) the delineation of liver vasculature, (2) the overall image quality, and (3) artifact presence and consequent image impairment was performed. SNR of the liver parenchyma was measured for the contrast-enhanced 2D and 3D FLASH sequences. For statistical analysis, a Wilcoxon-Rank Test was used. Best delineation of non-enhanced liver vasculature and overall image quality was found for 2D FLASH MRI, with only slight improvement in vessel conspicuity after the application of contrast media. T2-weighted TSE imaging remained strongly impaired, falling short of diagnostic relevance and precluding a clinical application. Our results demonstrate the feasibility and diagnostic potential of dedicated contrast-enhanced 7 T liver MRI as well as the potential for non-contrast-enhanced angiographic application.

  10. Diffusion-weighted imaging in relation to morphology on dynamic contrast enhancement MRI. The diagnostic value of characterizing non-puerperal mastitis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lina; Chu, Jianguo; Zhang, Weisheng; Liu, Ailian; Song, Qingwei [First Affiliated Hospital of Dalian Medical University, Department of Radiology, Dalian, Liaoning (China); Hu, Jiani; Guys, Nicholas [Wayne State University, Department of Radiology, Detroit, MI (United States); Meng, Jinli [Chengban Branch of West China Hospital, Department of Radiology, Chengdu, Sichuan (China); Wang, Shaowu [Second Affiliated Hospital of Dalian Medical University, Department of Radiology, Dalian, Liaoning (China)

    2018-03-15

    To demonstrate the value of diffusion-weighted imaging (DWI) in the characterisation of mastitis lesions. Sixty-one non-puerperal patients with pathologically confirmed single benign mastitis lesions underwent preoperative examinations with conventional MRI and axial DWI. Patients were categorised into three groups: (1) periductal mastitis (PDM), (2) granulomatous lobular mastitis (GLM), and (3) infectious abscess (IAB). Apparent diffusion coefficient (ADC) values of each lesion were recorded. A one-way ANOVA with logistic analysis was performed to compare ADC values and other parameters. Discriminative abilities of DWI modalities were compared using the area under the receiver operating characteristic curve (AUC). P < 0.05 was considered statistically significant. ADC values differed significantly among the three groups (P = 0.003) as well as between PDM and IAB and between PDM and GLM. The distribution of non-mass enhancement on dynamic contrast-enhanced (DCE) MRI differed significantly among the three groups (P = 0.03) but not between any two groups specifically. There were no differences in lesion location, patient age, T{sub 2}WI or DWI signal intensity, enhancement type, non-mass internal enhancement, or mass enhancement characteristics among the three groups. ADC values and the distribution of non-mass enhancement are valuable in classifying mastitis subtypes. (orig.)

  11. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  12. Contrast-enhanced dynamic MR imaging in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Koenig, H.; Sieper, J.; Wolf, K.J.

    1989-01-01

    This paper reports on a study for the identification of different pannus formations. Twenty patients with advanced rheumatoid arthritis of the knee joint were examined with MR imaging primary to surgery. The authors used a 1.5-T Magnetom unit, a circular surface coil for signal detection, 0.1 mmol/kg of Gd-DTPA given as a bolus injection, fast low-angle shot (FLASH) sequence (TR, 30 msec; TE, 10 msec; 128 x 128 matrix; excitation angle, 70 degrees) repeated 30 times within 120 seconds, and a T1-weighted spin-echo sequence (Tr, 500 msec; TE, 22 msec) before and 2 minutes after contrast medium injection. Enhancement of pannus and joint effusion has been measured and standardized to muscle tissue

  13. Dynamic contrast enhanced MRI in the differential diagnosis of adrenal adenomas and malignant adrenal masses

    International Nuclear Information System (INIS)

    Inan, Nagihan; Arslan, Arzu; Akansel, Gur; Anik, Yonca; Balci, N. Cem; Demirci, Ali

    2008-01-01

    Objective: To evaluate the value of dynamic MR imaging in the differential diagnosis of adrenal adenomas and malignant tumors, especially in cases with atypical adenomas. Materials and methods: Sixty-four masses (48 adenomas, 16 malignant tumors) were included in this prospective study. Signal loss of masses was evaluated using chemical shift MR imaging. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, with the acquisition starting simultaneously with i.v. contrast administration (0-100 s) followed by a T1-weighted FFE sequence in the late phase (5th minute). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained according to the SIs on the 0th, 25th, 50th 75th and 100th second. Also, the wash-in rate, maximum relative enhancement, time-to-peak, and wash-out of contrast at 100 s of masses in both groups were calculated. The statistical significance was determined by Mann-Whitney U test. To evaluate the diagnostic performance of the quantitative tests, receiver operating characteristic (ROC) analysis was performed. Results: Chemical shift MR imaging was able to differentiate 44 out of 48 adenomas (91.7%) from non-adenomas. The 4 adenomas (8.3%) which could not be differentiated from non-adenomas by this technique did not exhibit signal loss on out-of-phase images. With a cut-off value of 30, SI indices of adenomas had a sensitivity of 93.8%, specificity of 100% and a positive predictive value of 100%. On visual evaluation of dynamic MR imaging, early phase contrast enhancement patterns were homogeneous in 75% and punctate in 20,83% of the adenomas; while patchy in 56.25% and peripheral in 25% of the malignant tumors. On the late phase images 58.33% of the adenomas showed peripheral ring-shaped enhancement and 10.41% showed heterogeneous enhancement. All of the malignant masses showed heterogeneous

  14. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  15. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-01-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T p ); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T p were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS

  16. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    International Nuclear Information System (INIS)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig; Gultekin, David H.; Zheng, Junting; Moskowitz, Chaya; Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J.; Schwartz, Lawrence H.

    2011-01-01

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K trans , k ep , v e , AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values -3 mm 2 /s)], median K trans [1.07 vs. 0.34 (1/min)], and k ep [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  17. Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Kakite, Suguru, E-mail: sugkaki@med.tottori-u.ac.jp [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kurosaki, Masamichi [Department of Neurosurgery, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kanasaki, Yoshiko; Matsusue, Eiji; Kaminou, Toshio; Ogawa, Toshihide [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan)

    2011-07-15

    Introduction: To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0 Tesla (T). Methods: We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0 T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality. Results: At 3.0 T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts. Conclusion: Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0 T.

  18. Postcontrast T1-weighted brain magnetic resonance imaging in pediatric patients: comparison between postcontrast fat-suppression imaging and conventional T1-weighted or magnetization transfer imaging

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Goo, Hyun Woo

    2004-01-01

    We wished to assess the merits and weaknesses of postcontrast fat-suppression (FS) brain MR imaging in children for the evaluation of various enhancing lesions as compared with postcontrast conventional T1-weighted or magnetization transfer (MT) imaging. We reviewed the records of those patients with enhancing lesions on brain MR imaging who had undergone both FS imaging and one of the conventional T1-weighted or MT imaging as a post-contrast T1-weighted brain MR imaging. Thirty-one patients (21 male, 10 female; mean age, 8.7 years) with 38 enhancing lesions (18 intra-axial, 16 extra-axial and 4 orbital locations) were included in this study. There were 27 pairs of FS and conventional imagings, and 13 pairs of FS and MT imagings available for evaluation. Two radiologists visually assessed by consensus the lesions' conspicuity, and they also looked for the presence of flow or susceptibility artifacts in a total of 40 pairs of MR imagings. For 19 measurable lesions (14 pairs of FS and conventional T1-weighted imagings, 5 pairs of FS and MT imagings), the contrast ratios between the lesion and the normal brain ([SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared. Compared with conventional imaging, the lesion conspicuity on FS imaging was better in 10 cases (7 extra-axial lesions, 2 orbital lesions and 1 fat-containing intra-axial lesion), equal in 16 cases, and worse in one case. Compared with MT imaging, the lesion conspicuity on FS imaging was better in 3 cases (2 extra-axial lesions and 1 intra-axial lesion), equal in 8 cases, and worse in 2 cases. Image quality of FS imaging was compromised by flow or susceptibility artifacts for 7 patients. The contrast ratios for FS imaging were not significantly different from those for conventional imaging (2.2±0.7 vs. 2.2±0.6, respectively, p=0.914) and they were significantly lower than those for MT imaging (2.4±0.8 vs. 4.5±1.5, respectively, p=0.018). Postcontrast FS brain MR imaging appears to be

  19. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    International Nuclear Information System (INIS)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V.

    2010-01-01

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  20. Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy.

    Science.gov (United States)

    Fayad, Laura M; Mugera, Charles; Soldatos, Theodoros; Flammang, Aaron; del Grande, Filippo

    2013-07-01

    We demonstrate the clinical use of an MR angiography sequence performed with sparse k-space sampling (MRA), as a method for dynamic contrast-enhanced (DCE)-MRI, and apply it to the assessment of sarcomas for treatment response. Three subjects with sarcomas (2 with osteosarcoma, 1 with high-grade soft tissue sarcomas) underwent MRI after neoadjuvant therapy/prior to surgery, with conventional MRI (T1-weighted, fluid-sensitive, static post-contrast T1-weighted sequences) and DCE-MRI (MRA, time resolution = 7-10 s, TR/TE 2.4/0.9 ms, FOV 40 cm(2)). Images were reviewed by two observers in consensus who recorded image quality (1 = diagnostic, no significant artifacts, 2 = diagnostic, 75 % with good response, >75 % with poor response). DCE-MRI findings were concordant with histological response (arterial enhancement with poor response, no arterial enhancement with good response). Unlike conventional DCE-MRI sequences, an MRA sequence with sparse k-space sampling is easily integrated into a routine musculoskeletal tumor MRI protocol, with high diagnostic quality. In this preliminary work, tumor enhancement characteristics by DCE-MRI were used to assess treatment response.

  1. Combined dynamic contrast-enhancement and serial 3D-subtraction analysis in magnetic resonance imaging of osteoid osteomas

    Energy Technology Data Exchange (ETDEWEB)

    Kalle, T. von; Winkler, P. [Klinikum Stuttgart Olgahospital, Department of Paediatric Radiology, Stuttgart (Germany); Langendoerfer, M.; Fernandez, F.F. [Klinikum Stuttgart Olgahospital, Department of Paediatric Orthopaedics, Stuttgart (Germany)

    2009-10-15

    The purpose of this study was to retrospectively correlate the results of dynamic contrast-enhanced magnetic resonance imaging (MRI) with histological and clinical diagnoses in patients with osteoid osteomas. Fifty-four patients with the MR diagnosis of osteoid osteoma were studied. MRI (1.5 Tesla) consisted of thin-section STIR sequences, dynamic 3D T1 gradient echo sequences during application of contrast material, and high-resolution postcontrast T1 spin echo sequences with fat saturation (maximum voxel size 0.6 x 0.6 x 3.0 mm). Evaluation was focused on serial image subtraction during the early phase after contrast injection and on time-intensity curves. The surrounding edema was helpful in finding the nidus in each lesion. In 49 of 54 patients (90.7%), the diagnosis of osteoid osteoma was certain or highly probable (sensitivity 1.0, positive predictive value 0.91). A total of 38 of 54 osteoid osteomas were histologically proven. Five MRI diagnoses were regarded as false positives. A similar proportion has been reported for computed tomography. Tailored high-resolution MR examinations with dynamic contrast enhancement can reliably diagnose osteoid osteomas and exactly localize the nidus without radiation exposure. We propose a stepwise approach with STIR sequences, dynamic contrast-enhanced scanning, and high-resolution postcontrast T1 spin echo sequences with fat saturation. (orig.)

  2. Combined dynamic contrast-enhancement and serial 3D-subtraction analysis in magnetic resonance imaging of osteoid osteomas

    International Nuclear Information System (INIS)

    Kalle, T. von; Winkler, P.; Langendoerfer, M.; Fernandez, F.F.

    2009-01-01

    The purpose of this study was to retrospectively correlate the results of dynamic contrast-enhanced magnetic resonance imaging (MRI) with histological and clinical diagnoses in patients with osteoid osteomas. Fifty-four patients with the MR diagnosis of osteoid osteoma were studied. MRI (1.5 Tesla) consisted of thin-section STIR sequences, dynamic 3D T1 gradient echo sequences during application of contrast material, and high-resolution postcontrast T1 spin echo sequences with fat saturation (maximum voxel size 0.6 x 0.6 x 3.0 mm). Evaluation was focused on serial image subtraction during the early phase after contrast injection and on time-intensity curves. The surrounding edema was helpful in finding the nidus in each lesion. In 49 of 54 patients (90.7%), the diagnosis of osteoid osteoma was certain or highly probable (sensitivity 1.0, positive predictive value 0.91). A total of 38 of 54 osteoid osteomas were histologically proven. Five MRI diagnoses were regarded as false positives. A similar proportion has been reported for computed tomography. Tailored high-resolution MR examinations with dynamic contrast enhancement can reliably diagnose osteoid osteomas and exactly localize the nidus without radiation exposure. We propose a stepwise approach with STIR sequences, dynamic contrast-enhanced scanning, and high-resolution postcontrast T1 spin echo sequences with fat saturation. (orig.)

  3. Repeatability and correlations of dynamic contrast enhanced and T2* MRI in patients with advanced pancreatic ductal adenocarcinoma

    NARCIS (Netherlands)

    Klaassen, Remy; Gurney-Champion, Oliver J.; Wilmink, Johanna W.; Besselink, Marc G.; Engelbrecht, Marc R. W.; Stoker, Jaap; Nederveen, Aart J.; van Laarhoven, Hanneke W. M.

    2018-01-01

    In current oncological practice of pancreatic ductal adenocarcinoma (PDAC), there is a great demand for response predictors and markers for early treatment evaluation. In this study, we investigated the repeatability and the interaction of dynamic contrast enhanced (DCE) and T2* MRI in patients with

  4. Contrast-enhanced dynamic and diffusion-weighted MR imaging at 3.0 T to assess aggressiveness of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Guoxing, E-mail: sheasthospital@163.com [Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120 (China); Chen, Xiao, E-mail: chx_win@163.com [Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120 (China); Department of Radiology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing 210029 (China); Zhang, Jianhua [Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120 (China); Zhu, Jingqi, E-mail: zjh1830@easthospital.cn [Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120 (China); Zong, Genlin, E-mail: zgl0577@easthospital.cn [Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120 (China); Wang, Zhongqiu, E-mail: zhq2001us@163.com [Department of Radiology, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing 210029 (China)

    2014-11-15

    Highlights: • Wash out rate is associated with the aggressiveness of bladder cancer (BC). • Apparent diffusion coefficient (ADC) value could be used to assess the aggressiveness of BC. • The diagnostic accuracy of aggressiveness of BC using ADC was better than semi-quantitative parameters. • Our data showed a good diagnostic performance of ADC and wash-out together in assessing BC aggressiveness. - Abstract: Background: Diffusion weighted magnetic resonance imaging (DWI) and dynamic contrast-enhanced (DCE) MRI have been considered useful for pathological staging and histological grading in bladder cancer. To our knowledge, no study has combined the two imaging modalities together to assess aggressiveness of bladder cancer. Objective: To assess the clinical aggressiveness of bladder cancer with DCE MRI and DWI at 3.0 T. Materials and methods: A total of 59 patients with 69 pathologically confirmed tumor lesions were included in this study. All patients underwent MR examination at 3.0 T basing on DWI and DCE imaging. Tumor staging and histological grade were evaluated. The aggressiveness of bladder cancer was classified as low-, intermediate-, or high-aggressiveness according to its pathological phenotype. Apparent diffusion coefficient (ADC) value and semi-quantitative parameters (wash-in rate and wash-out rate) were determined. The correlation between clinical aggressiveness and ADC value, wash-in rate and wash-out rate were analyzed. In addition, the diagnostic accuracy of the diffusion and semi-quantitative parameters were estimated using receiver operating characteristic curve (ROC). Results: Aggressiveness of bladder cancer is negatively correlated with ADC value (r = −0.705, p < 0.0001) and wash-out rate (r = −0.719, p < 0.0001). The tumor ADC value is positively correlated with wash-out rate (r = 0.555, p < 0.0001). The diagnostic specificity and accuracy using tumor ADC value and wash-out for the tumor with size <24 mm were better than that

  5. Contrast-enhanced dynamic and diffusion-weighted MR imaging at 3.0 T to assess aggressiveness of bladder cancer

    International Nuclear Information System (INIS)

    Zhou, Guoxing; Chen, Xiao; Zhang, Jianhua; Zhu, Jingqi; Zong, Genlin; Wang, Zhongqiu

    2014-01-01

    Highlights: • Wash out rate is associated with the aggressiveness of bladder cancer (BC). • Apparent diffusion coefficient (ADC) value could be used to assess the aggressiveness of BC. • The diagnostic accuracy of aggressiveness of BC using ADC was better than semi-quantitative parameters. • Our data showed a good diagnostic performance of ADC and wash-out together in assessing BC aggressiveness. - Abstract: Background: Diffusion weighted magnetic resonance imaging (DWI) and dynamic contrast-enhanced (DCE) MRI have been considered useful for pathological staging and histological grading in bladder cancer. To our knowledge, no study has combined the two imaging modalities together to assess aggressiveness of bladder cancer. Objective: To assess the clinical aggressiveness of bladder cancer with DCE MRI and DWI at 3.0 T. Materials and methods: A total of 59 patients with 69 pathologically confirmed tumor lesions were included in this study. All patients underwent MR examination at 3.0 T basing on DWI and DCE imaging. Tumor staging and histological grade were evaluated. The aggressiveness of bladder cancer was classified as low-, intermediate-, or high-aggressiveness according to its pathological phenotype. Apparent diffusion coefficient (ADC) value and semi-quantitative parameters (wash-in rate and wash-out rate) were determined. The correlation between clinical aggressiveness and ADC value, wash-in rate and wash-out rate were analyzed. In addition, the diagnostic accuracy of the diffusion and semi-quantitative parameters were estimated using receiver operating characteristic curve (ROC). Results: Aggressiveness of bladder cancer is negatively correlated with ADC value (r = −0.705, p < 0.0001) and wash-out rate (r = −0.719, p < 0.0001). The tumor ADC value is positively correlated with wash-out rate (r = 0.555, p < 0.0001). The diagnostic specificity and accuracy using tumor ADC value and wash-out for the tumor with size <24 mm were better than that

  6. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar [SGRR Institute of Medical and Health Sciences, Patel Nagar, Dehradun (India)

    2017-11-15

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol.

  7. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    International Nuclear Information System (INIS)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar

    2017-01-01

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol

  8. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun [College of Medicine, Inje University, Seoul (Korea, Republic of)

    2000-02-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  9. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    International Nuclear Information System (INIS)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun

    2000-01-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  10. Utility of dual echo T2-weighted turbo spin echo MR imaging for differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Lee, Eun Joo; Kim, Jong Ho; Kim, Hyung Sik; Chung, Jin Woo

    1999-01-01

    To evaluate the additive value of multiphasic contrast-enhanced dynamic MR imaging as a supplement to dual-echo T2-weighted TSE MR imaging for the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions. Two radiologists retrospectively reviewed dual-echo T2-weighted TSE MR images and gadolinium-enhanced MR images in 51 patients with hepatic lesions (28 malignant, 69 benign). For the differentiation of malignant from benign lesions, as seen on dual-echo T2-weighted TSE MR images, we evaluated sensitivity, specificity, and accuracy, and compared with the results with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. In addition, Az values for dual echo T2-weighted MR images were compared with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. For the differentiation of malignant from benign hepatic lesions, as seen on dual-echo T2-weighted TSE images, sensitivity, specificity, and accuracy were 80.0%, 97.5%, and 93.9%, respectively, for lesions less than 3cm in diameter, and 92.3%, 95.0%, and 93.5%, respectively, for those that were 3cm or larger. The results for dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging were 86.7%, 100.0%, and 97.3%, respectively, for lesions less than 3cm, and 92.3%, 100.0%, and 95.7%, respectively for those that were 3cm or larger. There were no significant differences in sensitivity, specificity, or accuracy between the results obtained using dual-echo T2-weighted MR imaging and those obtained with dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging. Nor were these statistically significant differences in Az values between the two groups. For the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions, there is no difference in accuracy between dual-echo T2-weighted TSE MR imaging and the additional use of

  11. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

    Directory of Open Access Journals (Sweden)

    Sonja Kinner

    Full Text Available Preoperative evaluation of potential living liver donors (PLLDs includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w and Gd-EOB-DTPA enhanced T1-weighted (T1w magnetic resonance cholangiography (MRC techniques in the evaluation of PLLDs.30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany using (A 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo fat saturated (fs in axial plane, (B 2D T2w HASTE fs thick slices in coronal plane, (C free breathing 3D T2w TSE (turbo spin echo RESTORE (high-resolution navigator corrected plus (D maximum intensity projections (MIPs, (E T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions plus (F MIPs and (G T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G and with (H inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated.Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622-0.804.3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.

  12. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, 466-8550, Nagoya (Japan); Aoki, Ikuo [Medical System Company, Toshiba Corporation, Tokyo (Japan)

    2003-12-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 ) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in

  13. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  14. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  15. Dynamic contrast-enhanced MRI examination of atherosclerotic plaques: an animal study using rabbit model

    International Nuclear Information System (INIS)

    Li Mingli; Sun Jie; Chang Xiaoyan; Jin Zhengyu

    2011-01-01

    Objective: The enhanced patterns of atherosclerotic plaque on dynamic contrast- enhanced MRI have not been well studied. The aim of this study was to explore the patterns of plaque enhancement and their underlying mechanism by using dynamic contrast-enhanced MRI (DCE-MRI). Methods: Atherosclerotic plaques were induced in the aorta of 12 New Zealand White rabbits by a combination of endothelial denudation and high-cholesterol diet. Ten to sixteen weeks after surgery, DCE- MRI was performed with a fast spin echo T 1 weighted sequence. Thirty-five phases of images were obtained at 71-second intervals. Gd-DTPA was injected coincident with the third scan via marginal ear vein. Specimens were harvested within 12 hours after imaging for HE staining and CD31 immunohistochemical staining which was used to highlight neo-vessels. Plaque enhancement patterns were studied and compared with histological findings. Signal intensity of each plaque section was normalized to pre-contrast signal intensity of psoas muscle, after which signal intensity versus time curve was drawn. Pearson correlation coefficient was used to reveal association between histological neo-vessel count and descriptive parameters derived from signal intensity versus time curve. Results: Plaques were significantly enhanced by Gd-DTPA. Enhancement patterns could be described as 'fast-in and slow-out'. Differences in patterns of enhancement were observed between tissues, with fibrous tissue enhanced more than lipid aggregation and leukocyte foci. Peak enhancement (1.05±0.30), initial slope (0.82±0.28) and area under the curve at early phase (4.97± 1.67) derived from signal intensity-time curve had significant correlations with neo-vessel count (117.7± 93.3) (r=0.553, 0.468, 0.554 respectively, P<0.05). Conclusions: The enhanced patterns of atherosclerotic plaque by Gd-DTPA were 'fast- in and slow-out'. Neovascularization, increased endothelial permeability and extracellular matrix may be the reasons for

  16. Intraindividual comparison of myocardial delayed enhancement MR imaging using gadobenate dimeglumine at 1.5 T and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, Bernhard D.; Seeger, Achim; Fenchel, Michael; Kramer, Ulrich; Claussen, Claus D.; Miller, Stephan [Eberhard Karls University Tuebingen, Department for Diagnostic Radiology, Tuebingen (Germany); Sandstede, Joern [Roentgenzentrum, Hamburg (Germany); Lodemann, Klaus P. [Bracco Altana Pharma, Konstanz (Germany); Hoevelborn, Tobias [Eberhard Karls University Tuebingen, Department for Cardiology, Tuebingen (Germany)

    2009-05-15

    For contrast-enhanced imaging techniques relying on strong T1 weighting, 3 T provides increased contrast compared with 1.5 T. The aim of our study was the intraindividual comparison of delayed enhancement MR imaging at 1.5 T and at 3 T. Twenty patients with myocardial infarction were examined at 1.5 T and 3 T. Fifteen minutes after injection of contrast agent (0.1 mmol gadobenate dimeglumine per kg body weight), inversion recovery gradient recalled echo (IR-GRE) sequences were acquired (1.5 T/3 T: TR 11.0/9.9 ms, TE 4.4/4.9 ms, flip 30 /30 , slice thickness 6/6 mm) to assess myocardial viability. Two observers rated image quality (Wilcoxon signed rank test). Quantification of hyperenhanced myocardium and standardized SNR/CNR measurements were performed (Student's t test). There was no significant difference with respect to image quality (1.5 T/3 T: 3.5/3.3, p = 0.34, reader 1; 2.4/2.7, p = 0.12, reader 2) and infarction size (760 {+-} 566/828 {+-} 677 mm{sup 2} at 1.5 T, 808 {+-} 639/826 {+-} 726 mm{sup 2} at 3 T, reader 1/reader 2, p > 0.05). Mean SNR in hyperenhanced/normal myocardium was 19.2/6.2 at 1.5 T and 29.5/8.8 at 3 T (p < 0.05). Mean CNR was 14.3 at 1.5 T and 26.0 at 3 T (p < 0.05). Delayed enhancement MR imaging at 3 T is a robust procedure yielding superior tissue contrast at 3 T compared with 1.5 T which is, however, not reflected by increased image quality. (orig.)

  17. Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Mugera, Charles; Grande, Filippo del; Soldatos, Theodoros; Flammang, Aaron

    2013-01-01

    We demonstrate the clinical use of an MR angiography sequence performed with sparse k-space sampling (MRA), as a method for dynamic contrast-enhanced (DCE)-MRI, and apply it to the assessment of sarcomas for treatment response. Three subjects with sarcomas (2 with osteosarcoma, 1 with high-grade soft tissue sarcomas) underwent MRI after neoadjuvant therapy/prior to surgery, with conventional MRI (T1-weighted, fluid-sensitive, static post-contrast T1-weighted sequences) and DCE-MRI (MRA, time resolution = 7-10 s, TR/TE 2.4/0.9 ms, FOV 40 cm 2 ). Images were reviewed by two observers in consensus who recorded image quality (1 = diagnostic, no significant artifacts, 2 = diagnostic, 75 % with good response, >75 % with poor response). DCE-MRI findings were concordant with histological response (arterial enhancement with poor response, no arterial enhancement with good response). Unlike conventional DCE-MRI sequences, an MRA sequence with sparse k-space sampling is easily integrated into a routine musculoskeletal tumor MRI protocol, with high diagnostic quality. In this preliminary work, tumor enhancement characteristics by DCE-MRI were used to assess treatment response. (orig.)

  18. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo

    2017-01-01

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory

  19. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-04-15

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory.

  20. Importance of contrast-enhanced fluid-attenuated inversion reconvery magnetic resonance imaging in various intracranial pathologic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung; Lee, Eun Ja; Kim, Sung Won; Lee, Yong Seok [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang(Korea, Republic of)

    2016-02-15

    Intracranial lesions may show contrast enhancement through various mechanisms that are closely associated with the disease process. The preferred magnetic resonance sequence in contrast imaging is T1-weighted imaging (T1WI) at most institutions. However, lesion enhancement is occasionally inconspicuous on T1WI. Although fluid-attenuated inversion recovery (FLAIR) sequences are commonly considered as T2-weighted imaging with dark cerebrospinal fluid, they also show mild T1-weighted contrast, which is responsible for the contrast enhancement. For several years, FLAIR imaging has been successfully incorporated as a routine sequence at our institution for contrast-enhanced (CE) brain imaging in detecting various intracranial diseases. In this pictorial essay, we describe and illustrate the diagnostic importance of CE-FLAIR imaging in various intracranial pathologic conditions.

  1. Local contrast-enhanced MR images via high dynamic range processing.

    Science.gov (United States)

    Chandra, Shekhar S; Engstrom, Craig; Fripp, Jurgen; Neubert, Ales; Jin, Jin; Walker, Duncan; Salvado, Olivier; Ho, Charles; Crozier, Stuart

    2018-09-01

    To develop a local contrast-enhancing and feature-preserving high dynamic range (HDR) image processing algorithm for multichannel and multisequence MR images of multiple body regions and tissues, and to evaluate its performance for structure visualization, bias field (correction) mitigation, and automated tissue segmentation. A multiscale-shape and detail-enhancement HDR-MRI algorithm is applied to data sets of multichannel and multisequence MR images of the brain, knee, breast, and hip. In multisequence 3T hip images, agreement between automatic cartilage segmentations and corresponding synthesized HDR-MRI series were computed for mean voxel overlap established from manual segmentations for a series of cases. Qualitative comparisons between the developed HDR-MRI and standard synthesis methods were performed on multichannel 7T brain and knee data, and multisequence 3T breast and knee data. The synthesized HDR-MRI series provided excellent enhancement of fine-scale structure from multiple scales and contrasts, while substantially reducing bias field effects in 7T brain gradient echo, T 1 and T 2 breast images and 7T knee multichannel images. Evaluation of the HDR-MRI approach on 3T hip multisequence images showed superior outcomes for automatic cartilage segmentations with respect to manual segmentation, particularly around regions with hyperintense synovial fluid, across a set of 3D sequences. The successful combination of multichannel/sequence MR images into a single-fused HDR-MR image format provided consolidated visualization of tissues within 1 omnibus image, enhanced definition of thin, complex anatomical structures in the presence of variable or hyperintense signals, and improved tissue (cartilage) segmentation outcomes. © 2018 International Society for Magnetic Resonance in Medicine.

  2. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Gultekin, David H. [Memorial Sloan-Kettering Cancer Center, Medical Physics, New York, NY (United States); Zheng, Junting; Moskowitz, Chaya [Memorial Sloan-Kettering Cancer Center, Epidemiology and Biostatistics, New York, NY (United States); Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J. [Memorial Sloan-Kettering Cancer Center, Radiation Oncology, New York, NY (United States); Schwartz, Lawrence H. [Columbia University College of Physicians and Surgeons, Radiology, New York, NY (United States)

    2011-09-15

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K{sup trans}, k{sub ep}, v{sub e}, AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values < 0.05). Biopsy-positive and biopsy-negative prostate sides differed significantly in median ADC [1.44 vs. 1.68 (x 10{sup -3} mm{sup 2}/s)], median K{sup trans} [1.07 vs. 0.34 (1/min)], and k{sub ep} [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  3. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    NARCIS (Netherlands)

    Nketiah, G.; Elschot, M.; Kim, E.; Teruel, J.R.; Scheenen, T.W.J.; Bathen, T.F.; Selnaes, K.M.

    2017-01-01

    PURPOSE: To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. MATERIALS AND METHODS:

  4. Added diagnostic value of T2-weighted MR imaging to gadolinium-enhanced three-dimensional dynamic MR imaging for the detection of small hepatocellular carcinomas

    International Nuclear Information System (INIS)

    Kim, Young Kon; Lee, Young Hwan; Kim, Chong Soo; Han, Young Min

    2008-01-01

    Purpose: To assess the added value of T2-weighted MRI to gadolinium-enhanced dynamic MRI for detection of HCCs. Materials and methods: Two readers retrospectively analyzed MRIs of 115 patients with 131 HCCs (size; 0.6-2.0 cm) that had been diagnosed by histology (n = 41) or imaging findings (n = 90). Two separate blind image analyses of the gadolinium set and the combined T2-weighted imaging and gadolinium sets were performed. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method with four-point scale. Sensitivity and positive predictive value were also calculated. Results: For both observers, the Az values and sensitivities with the combined T2-weighed imaging and gadolinium set (mean Az 0.806, sensitivity 84.7) were significantly higher than those with the gadolinium set (mean Az 0.660, sensitivity 59.9) (p < 0.05). The addition of T2-weighted imaging led to a change in diagnosis for 27 lesions by both observers, which at gadolinium set were assigned a confidence level of 1 or 2 but at additional reading of T2-weighted imaging were assigned a confidence level of 3 or 4. For the positive predictive values, each image set showed a similar value for each observer. Conclusion: The addition of T2-weighted imaging to gadolinium-enhanced 3D dynamic imaging could be helpful in the detection of HCC by increasing reader confidence for HCCs with equivocal findings on gadolinium-enhanced MRIs

  5. Assessment of Silent T1-weighted head imaging at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Costagli, Mauro; Tiberi, Gianluigi; Tosetti, Michela [Imago7 Foundation, Pisa (Italy); IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Symms, Mark R. [GE Applied Science Laboratory, Pisa (Italy); Angeli, Lorenzo [University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Kelley, Douglas A.C. [GE Healthcare Technologies, San Francisco, CA (United States); Biagi, Laura [IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Farnetani, Andrea [University of Ferrara, Engineering Department, Ferrara (Italy); Materiacustica s.r.l., Ferrara (Italy); Rua, Catarina [University of Pisa, Department of Physics, Pisa (Italy); Donatelli, Graziella [Azienda Ospedaliero-Universitaria Pisana (AOUP), Neuroradiology Unit, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Cosottini, Mirco [Imago7 Foundation, Pisa (Italy); University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy)

    2016-06-15

    This study aimed to assess the performance of a ''Silent'' zero time of echo (ZTE) sequence for T1-weighted brain imaging using a 7 T MRI system. The Silent sequence was evaluated qualitatively by two neuroradiologists, as well as quantitatively in terms of tissue contrast, homogeneity, signal-to-noise ratio (SNR) and acoustic noise. It was compared to conventional T1-weighted imaging (FSPGR). Adequacy for automated segmentation was evaluated in comparison with FSPGR acquired at 7 T and 1.5 T. Specific absorption rate (SAR) was also measured. Tissue contrast and homogeneity in Silent were remarkable in deep brain structures and in the occipital and temporal lobes. Mean tissue contrast was significantly (p < 0.002) higher in Silent (0.25) than in FSPGR (0.11), which favoured automated tissue segmentation. On the other hand, Silent images had lower SNR with respect to conventional imaging: average SNR of FSPGR was 2.66 times that of Silent. Silent images were affected by artefacts related to projection reconstruction, which nevertheless did not compromise the depiction of brain tissues. Silent acquisition was 35 dB(A) quieter than FSPGR and less than 2.5 dB(A) louder than ambient noise. Six-minute average SAR was <2 W/kg. The ZTE Silent sequence provides high-contrast T1-weighted imaging with low acoustic noise at 7 T. (orig.)

  6. Combined diffusion-weighted and dynamic contrast-enhanced imaging of patients with acute osteoporotic vertebral fractures

    International Nuclear Information System (INIS)

    Biffar, Andreas; Sourbron, Steven; Dietrich, Olaf; Schmidt, Gerwin; Ingrisch, Michael; Reiser, Maximilian F.; Baur-Melnyk, Andrea

    2010-01-01

    Objectives: To evaluate the potential and to analyze parameter correlations of combined quantitative diffusion-weighted MRI (DWI) and high-temporal-resolution dynamic contrast-enhanced MRI (DCE-MRI) in vertebral bone marrow (vBM) of patients with osteoporosis and acute vertebral compression fractures, providing additional information for a better understanding of the physiological background of parameter changes. Materials and methods: 20 patients with acute osteoporotic fractures were examined with DWI and DCE-MRI at 1.5 T. DCE-MRI was performed with a 2D saturation-recovery turbo-FLASH sequence, acquiring 300 dynamics with a temporal resolution of 1 s. For DWI measurements, a DW HASTE sequence with b-values from 100 to 600 s/mm 2 was applied. In each patient, ROIs were drawn manually in the fractures and in normal appearing vertebrae. For DCE-MRI, the concentration-time curves of these ROIs were analyzed using a two-compartment tracer-kinetic model in the lesions, providing separate estimates of perfusion and permeability, and a one-compartment model in normal vBM, providing only a mixed representation of perfusion and permeability in terms of a mixed flow parameter K trans and the extracellular volume (ECV). In the case of DWI, attenuation curves were fitted to a monoexponential decay model to determine the apparent diffusion coefficient (ADC). Results: Mean perfusion parameters and ADCs were significantly (p trans : 7.81 mL/100 mL/min vs. 14.61 mL/100 mL/min, ECV: 52.84 mL/100 mL vs. 4.61 mL/100 mL, ADC: 1.71 x 10 -3 mm 2 /s vs. 0.57 x 10 -3 mm 2 /s). ADCs showed a significant correlation with the ECV. Conclusion: The quantitative analysis of DWI and DCE-MRI could distinguish osteoporotic fractures from normal appearing vertebrae. A significant correlation found between ECV and ADCs might be able to explain the cause for the increased diffusivity in osteoporotic fractures. Since the other perfusion parameters do not correlate with the ADC, they provide

  7. Changes in signal-to-noise ratios and contrast-to-noise ratios of hypervascular hepatocellular carcinomas on ferucarbotran-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Park, Yulri; Choi, Dongil; Kim, Seong Hyun; Kim, Seung Hoon; Kim, Min Ju; Lee, Jongmee; Lim, Jae Hoon; Lee, Won Jae; Lim, Hyo K.

    2006-01-01

    Purpose: To verify changes in the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of hypervascular hepatocellular carcinomas (HCCs) on ferucarbotran-enhanced dynamic T1-weighted MR imaging. Materials and methods: Fifty-two patients with 61 hypervascular HCCs underwent ferucarbotran-enhanced dynamic MR imaging, and then hepatic resection. Hypervascular HCCs were identified when definite enhancement was noted during the arterial dominant phase of three-phase MDCT. Dynamic MR Images with T1-weighted fast multiplanar spoiled gradient-recalled echo sequence (TR200/TE4.2) were obtained before and 20 s, and 1, 3, 5, and 10 min, after bolus injection of ferucarbotran. We estimated the signal intensities of tumors and livers, and calculated the SNRs and CNRs of the tumors. Results: On ferucarbotran-enhanced dynamic MR imaging, SNR measurements showed a fluctuating pattern, namely, an increase in SNR followed by a decrease and a subsequent increase (or a decrease in SNR followed by a increase and a subsequent decrease) in 50 (82.0%) of 61 tumors, a single-peak SNR pattern (highest SNR on 20 s, 1, 3, or 5 min delayed images followed by a decrease) in seven (11.5%), and a decrease in SNR followed by an increase in four (6.6%). Maximum absolute CNRs with positive value were noted on 10 min delayed images in 41 (67.2%) tumors, and maximum absolute CNRs with negative value were observed on 20 s delayed images in 12 (19.7%) and on 1 min delayed images in eight (13.1%). Conclusion: Despite showing various SNR and CNR changes, the majority of hypervascular HCCs demonstrated a fluctuating SNR pattern on ferucarbotran-enhanced dynamic MR imaging and a highest CNR on 10 min delayed image, which differed from the classic enhancement pattern on multiphasic CT

  8. Evaluating automated dynamic contrast enhanced wrist 3T MRI in healthy volunteers

    DEFF Research Database (Denmark)

    Rastogi, Anshul; Kubassova, Olga; Krasnosselskaia, Lada V

    2013-01-01

    Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so...

  9. Combined value of susceptibility weighted imaging and dynamic susceptibility-weighted contrast-enhanced MR perfusion-weighted imaging in brain astrocytoma grading

    International Nuclear Information System (INIS)

    Wang Xiaochun; Zhang Hui; Qin Jiangbo; Wang Le; Wu Xiaofeng

    2012-01-01

    Objective: To assess the value of combination of susceptibility weighted imaging (SWI) and dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion-weighted magnetic resonance imaging in astrocytoma grading. Methods: SWI and DSC scans were performed in 82 patients with pathologically confirmed astrocytoma. The patient group consisted of grade Ⅱ (15), grade Ⅲ (10), and grade Ⅳ (57). The intratumoral susceptibility signal intensity (ITSS) and relative cerebral blood volume (rCBV) max were used to determine the grade of astrocytomas by Kruskal Wallis test, Welch test, Spearman correlation coefficients, Pearson correlation coefficients, and receiver operating characteristic curve (ROC)statistic methods. Results: There were no ITSS in 14 cases of low-grade astrocytomas, the degree of ITSS were grade 1 to 3 in anaplastic astrocytomas, the degree of ITSS were grade 3 in all of the glioblastomas, the degree of ITSS were significant difference in all grades (H=71.96, P<0.01). rCBV max in grade Ⅱ, grade Ⅲ and grade Ⅳ astrocytomas were 1.26 ± 0.42, 3.59 ± 2.09 and 8.34 ± 1.16 respectively, rCBV max were significant difference in all grades (F'=681.72, P<0.01). ITSS showed significant correlation with rCBV max (r=0.72, P<0.01) and tumor grades (r=0.89, P<0.01), and rCBV and tumor grades showed significant correlation (r=0.78, P<0.01). Area under the ROC curve application SWI, DSC, SWI and DSC in differentiation of the grade Ⅱ and grade Ⅲ astrocytomas were 0.99, 0.93, 1.00, differentiate grade Ⅲ from grade Ⅳ were 0.70, 0.94, 0.94, and differentiate high-grade from low-grade astrocytomas were 1.00, 0.99, 1.00. Conclusions: ITSS is helpful to determine the grade of astrocytomas. The use of SWI in combination with DSC may improve the diagnostic accuracy of astrocytoma grading. (authors)

  10. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Dynamic contrast-enhanced breast MRI at 7T and 3T : an intra-individual comparison study

    NARCIS (Netherlands)

    de Lima Gomes de Menezes, G; Stehouwer, Bertine L; Klomp, DWJ; van der Velden, Tijl A; van den Bosch, Maurice A A J; Knuttel, Floor; Boer, VO; van der Kemp, Wybe J M; Luijten, Peter R; Veldhuis, Wouter B.

    2016-01-01

    The aim of this study is to compare the current state of lesion identification, the BI-RADS classification and the contrast-enhancement behavior at 7T and 3T breast MRI in the same patient group. Twenty-seven patients with thirty suspicious lesions were selected for this prospective study and

  12. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model; Detektion von Prostatakarzinomen mit T1-gewichteter Kontrastmittel-unterstuetzter dynamischer MRT. Wertigkeit des Zweikompartimentemodells

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U. [Abteilung fuer Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Grobholz, R. [Abteilung fuer Pathologie, Universitaetsklinikum Mannheim (Germany); Heilmann, M. [Abteilung fuer Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Michel, M.S.; Trojan, L. [Abteilung fuer Urologie, Universitaetsklinikum Mannheim (Germany); Werner, A.; Rabe, J. [Institut fuer Klinische Radiologie, Universitaetsklinikum Mannheim (Germany); Schlemmer, H.P. [Abteilung fuer Diagnostische Radiologie, Universitaetsklinikum Tuebingen (Germany)

    2003-06-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k{sub ep}).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k{sub ep}. Prostate carcinomas of the peripheral zone were demarcated by amplitude and k{sub ep}. In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k{sub ep} and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k{sub ep} reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [German] Die Eignung dynamischer Parameter des Zweikompartimentemodells zur Erkennung von Prostatakarzinomen und deren Korrelation mit der Tumormikrogefaessdichte wurden evaluiert. 43 Patienten mit bioptisch gesichertem Prostatakarzinom wurden untersucht, 28 mit 1,0 T- (Turbo-FLASH-) und 15 bei 1,5-T-MRT (FLASH) unter Infusion von 0,1 mmol/kg Gd-DTPA. Signal-Zeit-Kurven wurden nach einem offenen Zweikompartimentemodell in Amplitude sowie Austauschratenkonstante (k{sub ep}) parametrisiert. An resezierten Prostatakarzinomen wurde die Mikrogefaessdichte bestimmt.Ergebnisse Die Mikrogefaessdichte in den Tumoren war signifikant hoeher als im angrenzenden gesunden Prostatagewebe und korrelierte bei beiden Sequenzen mit k{sub ep

  13. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    Science.gov (United States)

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  14. Evaluating automated dynamic contrast enhanced wrist 3 T MRI in healthy volunteers: One-year longitudinal observational study

    Energy Technology Data Exchange (ETDEWEB)

    Rastogi, Anshul, E-mail: anshul.rastogi@bartshealth.nhs.uk [Kennedy Institute of Rheumatology, Imperial College London (United Kingdom); Kubassova, Olga, E-mail: olga@imageanalysis.org.uk [Image Analysis, Leeds (United Kingdom); Krasnosselskaia, Lada V., E-mail: solaguz@yahoo.com [Imaging Sciences Department, Imperial College London (United Kingdom); Lim, Adrian K.P., E-mail: a.lim@imperial.ac.uk [Department of Radiology, Imperial College Healthcare NHS Trust, London (United Kingdom); Satchithananda, Keshthra, E-mail: keshthra.satchithananda@imperial.nhs.uk [Department of Radiology, Imperial College Healthcare NHS Trust, London (United Kingdom); Boesen, Mikael, E-mail: mikael.boesen@gmail.com [Department of Radiology and the Parker Institute, Frederiksberg and Bispebjerg Hospitals (Denmark); Binks, Michael, E-mail: michael.h.binks@gsk.com [GlaxoSmithKline, Stevenage, SG1 2NY (United Kingdom); Hajnal, Joseph V., E-mail: jo.hajnal@kcl.ac.uk [Imaging Sciences Department, Imperial College London (United Kingdom); Taylor, Peter C., E-mail: peter.taylor@kennedy.ox.ac.uk [Kennedy Institute of Rheumatology, Imperial College London (United Kingdom)

    2013-08-15

    Rational and Objective: Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so as to differentiate changes induced by treatment from the inherent variability of perfusion measures. The objective of this study was to test a pixel-by-pixel parametric map based approach for analysis of DCE-MRI (Dynamika) and to investigate the variability in signal characteristics over time in healthy controls using longitudinally acquired images. Materials and Methods: 10 healthy volunteers enrolled, dominant wrists were imaged with contrast enhanced 3T MRI at baseline, week 12, 24 and 52 and scored with RAMRIS, DCE-MRI was analysed using a novel quantification parametric map based approach. Radiographs were obtained at baseline and week 52 and scored using modified Sharp van der Heidje method. RAMRIS scores and dynamic MRI measures were correlated. Results: No erosions were seen on radiographs, whereas MRI showed erosion-like changes, low grade bone marrow oedema and low-moderate synovial enhancement. The DCE-MRI parameters were stable (baseline scores, variability) (mean ± st.dev); in whole wrist analysis, ME{sub mean} (1.3 ± 0.07, −0.08 ± 0.1 at week 24) and IRE{sub mean} (0.008 ± 0.004, −0.002 ± 0.005 at week 12 and 24). In the rough wrist ROI, ME{sub mean} (1.2 ± 0.07, 0.04 ± 0.02 at week 52) and IRE{sub mean} (0.001 ± 0.0008, 0.0006 ± 0.0009 at week 52) and precise wrist ROI, ME{sub mean} (1.2 ± 0.09, 0.04 ± 0.04 at week 52) and IRE{sub mean} (0.001 ± 0.0008, 0.0008 ± 0.001 at week 24 and 52). The Dynamic parameters obtained using fully automated analysis demonstrated strong, statistically significant correlations with RAMRIS synovitis scores. Conclusion: The study demonstrated that contrast enhancement does occur in

  15. Dynamic MRI of tumours in head and neck with a contrast-enhanced FLASH-2D sequence

    International Nuclear Information System (INIS)

    Maeurer, J.; Rausch, M.; Richter, W.S.; Boeck, J.C.; Steinkamp, H.J.; Vogl, T.J.; Felix, R.

    1995-01-01

    The purpose of this study was to evaluate the utility of a dynamic contrast enhanced FLASH-2D sequence for differential diagnosis of tumours in head and neck in 93 patients. Initially, the localization of the lesion and the selection of four representative slices for the dynamic study were obtained by a T2-weighted spin-echo sequence (TR 2000-3000 ms; TE 25/90 ms). After IV bolus injection of the contrast agent 10 images were acquired during a period of 3 min by a FLASH-2D sequence (TR 60 ms; TE 6 ms; flip angle 40 ; matrix 256 x 256; one acquisition). The percentage signal intensity (SI) increase (r) and the slope (S) of the curve were calculated on the basis of the SI time curve of the pathological lesion and of muscle. Inflammatory processes could be differentiated from malignant or benign tumours by means of a higher contrast enhancement. The time of the maximum SI was not specific for the different lesions. In comparison with muscle the maximum SI change was achieved earlier in a pathological process. (orig.)

  16. T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-06-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as "intensity field bias". Such inhomogeneities mostly originate from heterogeneous RF coil B(1) profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T(1)-weighted (T(1)w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T(1) weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T(1) contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B(1) variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B(1) profiles become more heterogeneous. Another characteristic of T(1)w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T(2)(*) contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T(1)w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T(2)(*) contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 T, provide higher T(1) contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help in identifying small brain structures and that T(2)(*) induced artifacts can be removed from the images. The resulting unbiased T(1)w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T(1)w structural images. In addition

  17. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  18. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    International Nuclear Information System (INIS)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo

    1994-01-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author)

  19. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-09-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author).

  20. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  1. T1 weighted Brain Images at 7 Tesla Unbiased for Proton Density, T2* contrast and RF Coil Receive B1 Sensitivity with Simultaneous Vessel Visualization

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J.; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-01-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique

  2. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  3. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  4. Comparative evaluation of gadoteridol versus gadopentetate dimeglumine for contrast-enhanced MRI in a rat brain glioma model at 1.5 and 3.0 T

    International Nuclear Information System (INIS)

    Ai Fei; Qi Jianpin; Li Xiaoming; Runge, Val M.; Morelli, John N.; Vu, Lan.; Cannel, Jeremy; Loynachan, Alan T.

    2010-01-01

    Objective: To compare gadoteridol and gadopentetate dimeglumine (Gd-DTPA) with respect to lesion enhancement in a rat brain glioma model at 1. 5 and 3.0 T. Methods: Glioma cells were injected into the brains of 42 male CDF (Fisher 344) rats through implanted cannula to create Glioma animal model. One week after implantation, all rats were randomly divided in to four groups which included 12, 10, 10, 10 rats. The comparisons included the contrast effect of gadoteridol versus gadopentetate dimeglumine at both 1.5 and 3.0 T. In addition, gadoteridol alone was evaluated by comparing the standard dose at both two field strengths and half dose at 3.0 T to a standard full dose at 1.5 T. Two MRI scans for different contrast agent injections were performed in each animal model with an interval of 24 hours. T 1 -weighted images were analyzed pre-contrast and at five time points (1, 3, 5, 7 and 9 min) post-contrast with respect to lesion signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast enhancement (CE). Student t test was used for statistics. Results: The mean SNR, CNR, and CE were respectively 54.4±3.2, 17.0±3.3 and 20.8±3.4 with gadopentetate dimeglumine versus 53.2±3.2, 17.2±3.1 and 20.8±3.2 with gadoteridol at 1.5 T at every postconuast time point (t=2.247, 0.403, 0.076, P>0.05). The mean SNR, CNR, and CE were respectively 94.8±7.1, 38.0±6.0 and 45.0±6.3 with gadopentetate dimeglumine versus 95.5±2.9, 37.2±2.7 and 45.6±2.8 with gadoteridol at 3.0 T (t= 0.303, 0.573, 0.357, P>0.05). No statistically significant differences were found in these parameters between the two agents at any time point at either field strength. Standard dose gadoteridol demonstrated significant improvements in SNR (51.9±3.0 at 1.5 T vs 86.1±4.9 at 3.0 T), CNR (15.6±3.0 at 1.5 T vs 27.4±5.0 at 3.0 T) and CE (18.6±3.0 at 1.5 T vs 37.3±5.3 at 3.0 T) at 3.0 T as compared to 1.5 T at every time post-contrast (t=36.227, 11.977, 17.106, P 0.05). Conclusions

  5. Dynamic contrast-enhanced MRI of benign prostatic hyperplasia and prostatic carcinoma: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ren, J.; Huan, Y.; Wang, H.; Chang, Y.-J.; Zhao, H.-T.; Ge, Y.-L.; Liu, Y.; Yang, Y.

    2008-01-01

    Aim: To investigate the diagnostic and differential diagnostic values of dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) in prostatic diseases, and to investigate the correlation between the parameters of SI-T curves and angiogenesis. Materials and methods: Twenty-one patients with proven prostatic carcinoma (Pca) and 29 patients with proven benign prostatic hyperplasia (BPH) were examined using DCE MRI. Diagnostic characteristics for differentiation were examined using threshold values for maximum peak time, enhancement degree, and enhancement rate. Then, the signal intensity-time curves (SI-T curves) were analysed, and the correlations between the parameters of SI-T curves and the expression levels of vascular endothelial growth factor (VEGF) and microvascular density (MVD) were investigated. All patients underwent prostatectomy. DCE MRI and histological findings were correlated. Results: Pca showed stronger enhancement with an earlier peak time, higher enhancement, and enhancement rate (p 2 = 13.57, P < 0.005). The VEGF and MVD expression levels of Pca were higher than those of BPH. Peak time was negatively correlated with the expression levels of VEGF and MVD, whereas the enhancement degree and enhancement rate showed positive correlations (Pearson correlation, p < 0.05). Conclusion: Based on T2-weighted imaging, DCE MRI curves can help to differentiate benign from malignant prostate tissue. In the present study the type C curve was rarely seen with malignant disease, but these results need confirmation

  6. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    Science.gov (United States)

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of gadolinium deposition requires tissue analysis. Any potential clinical sequelae of gadolinium retention in

  7. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    International Nuclear Information System (INIS)

    Erdem, L. Oktay; Erdem, C. Zuhal; Acikgoz, Bektas; Gundogdu, Sadi

    2005-01-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times

  8. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  9. Dynamic contrast-enhanced and diffusion-weighted MR imaging in the characterisation of small, non-palpable solid testicular tumours

    International Nuclear Information System (INIS)

    Manganaro, Lucia; Saldari, Matteo; Pozza, Carlotta; Gianfrilli, Daniele; Isidori, Andrea M.; Vinci, Valeria; Sergi, Maria Eleonora; Catalano, Carlo; Greco, Ermanno; Franco, Giorgio; Scialpi, Michele

    2018-01-01

    To explore the role of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), using semiquantitative and quantitative parameters, and diffusion-weighted (DW) MRI in differentiating benign from malignant small, non-palpable solid testicular tumours. We calculated the following DCE-MRI parameters of 47 small, non-palpable solid testicular tumours: peak enhancement (PE), time to peak (TTP), percentage of peak enhancement (Epeak), wash-in-rate (WIR), signal enhancement ratio (SER), volume transfer constant (K trans ), rate constant (K ep ), extravascular extracellular space volume fraction (V e ) and initial area under the curve ( i AUC). DWI signal intensity and apparent diffusion coefficient (ADC) values were evaluated. E peak , WIR, K trans , K ep and iAUC were higher and TTP shorter in benign compared to malignant lesions (p < 0.05). All tumours had similar ADC values (p > 0.07). Subgroup analysis limited to the most frequent histologies - Leydig cell tumours (LCTs) and seminomas - replicated the findings of the entire set. Best diagnostic cutoff value for identification of seminomas: K trans ≤0.135 min -1 , K ep ≤0.45 min -1 , iAUC ≤10.96, WIR ≤1.11, Epeak ≤96.72, TTP >99 s. DCE-MRI parameters are valuable in differentiating between benign and malignant small, non-palpable testicular tumours, especially when characterising LCTs and seminomas. (orig.)

  10. Dynamic contrast-enhanced and diffusion-weighted MR imaging in the characterisation of small, non-palpable solid testicular tumours

    Energy Technology Data Exchange (ETDEWEB)

    Manganaro, Lucia; Saldari, Matteo [La Sapienza University of Rome, Department of Department of Radiological, Oncological and Anatomo-Pathological Sciences, Rome (Italy); Testis-Unit, Policlinico Umberto I, Rome (Italy); Pozza, Carlotta; Gianfrilli, Daniele; Isidori, Andrea M. [Testis-Unit, Policlinico Umberto I, Rome (Italy); La Sapienza University of Rome, Department of Experimental Medicine, Rome (Italy); Vinci, Valeria; Sergi, Maria Eleonora; Catalano, Carlo [La Sapienza University of Rome, Department of Department of Radiological, Oncological and Anatomo-Pathological Sciences, Rome (Italy); Greco, Ermanno [European Hospital, Centre for Reproductive Medicine, Rome (Italy); Franco, Giorgio [Testis-Unit, Policlinico Umberto I, Rome (Italy); La Sapienza University of Rome, Department Gynaecological-Obstetrical and Urological Sciences, Rome (Italy); Scialpi, Michele [Perugia University, S. Maria della Misericordia Hospital, Department of Surgical and Biomedical Sciences, Division of Radiology 2, Perugia (Italy)

    2018-02-15

    To explore the role of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), using semiquantitative and quantitative parameters, and diffusion-weighted (DW) MRI in differentiating benign from malignant small, non-palpable solid testicular tumours. We calculated the following DCE-MRI parameters of 47 small, non-palpable solid testicular tumours: peak enhancement (PE), time to peak (TTP), percentage of peak enhancement (Epeak), wash-in-rate (WIR), signal enhancement ratio (SER), volume transfer constant (K{sub trans}), rate constant (K{sub ep}), extravascular extracellular space volume fraction (V{sub e}) and initial area under the curve ({sub i}AUC). DWI signal intensity and apparent diffusion coefficient (ADC) values were evaluated. E{sub peak}, WIR, K{sub trans}, K{sub ep} and iAUC were higher and TTP shorter in benign compared to malignant lesions (p < 0.05). All tumours had similar ADC values (p > 0.07). Subgroup analysis limited to the most frequent histologies - Leydig cell tumours (LCTs) and seminomas - replicated the findings of the entire set. Best diagnostic cutoff value for identification of seminomas: K{sub trans} ≤0.135 min{sup -1}, K{sub ep} ≤0.45 min{sup -1}, iAUC ≤10.96, WIR ≤1.11, Epeak ≤96.72, TTP >99 s. DCE-MRI parameters are valuable in differentiating between benign and malignant small, non-palpable testicular tumours, especially when characterising LCTs and seminomas. (orig.)

  11. Evaluation of sacroiliitis: contrast-enhanced MRI with subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Algin, Oktay; Gokalp, Gokhan; Baran, Bulent; Ocakoglu, Gokhan; Yazici, Zeynep [Uludag University, Medical Faculty, Department of Radiology, Gorukle, Bursa (Turkey)

    2009-10-15

    The purpose of the study was to investigate the diagnostic value of contrast-enhanced MRI using the subtraction technique in the detection of active sacroiliitis. Magnetic resonance imaging was performed in 8 asymptomatic volunteers and 50 patients with clinically suspected active sacroiliitis. On precontrast MR images, T1-weighted spin-echo images with and without fat saturation (T1WFS and T1W), STIR and 3D-FLASH images with fat saturation were obtained in the semicoronal plane using a 1.5 Tesla imager. Postcontrast MRI was performed using the same T1WFS sequence as before contrast injection for all volunteers and patients. Postcontrast images were subtracted from fat-suppressed precontrast images. Enhancement within the joint space and bone marrow was considered to demonstrate active sacroiliitis. In 50 patients (100 sacroiliac joints [SIJs]), 40 (76 SIJs) were considered to have active sacroiliitis based on MR images. Bone marrow edema was present in 33 patients (62 SIJs) on STIR images. Routine MRI allowed identification of contrast enhancement in SIJs on postcontrast T1WFS images in 31 patients (49 SIJs). Contrast enhancement was observed in 40 patients (76 SIJs) who were examined by MRI using the subtraction technique. Contrast enhancement was significantly more conspicuous on subtraction images than on non-subtracted postcontrast T1WFS images (Mann-Whitney U test, p<0.001). Contrast-enhanced MRI with subtraction technique may be useful for early detection of active sacroiliitis. (orig.)

  12. Magnetic resonance imaging of pelvic entheses - a systematic comparison between short tau inversion recovery (STIR) and T1-weighted, contrast-enhanced, fat-saturated sequences

    International Nuclear Information System (INIS)

    Klang, Eyal; Aharoni, Dvora; Rimon, Uri; Eshed, Iris; Hermann, Kay-Geert; Herman, Amir; Shazar, Nachshon

    2014-01-01

    To assess the contribution of contrast material in detecting and evaluating enthesitis of pelvic entheses by MRI. Sixty-seven hip or pelvic 1.5-T MRIs (30:37 male:female, mean age: 53 years) were retrospectively evaluated for the presence of hamstring and gluteus medius (GM) enthesitis by two readers (a resident and an experienced radiologist). Short tau inversion recovery (STIR) and T1-weighted pre- and post-contrast (T1+Gd) images were evaluated by each reader at two sessions. A consensus reading of two senior radiologists was regarded as the gold standard. Clinical data was retrieved from patients' referral form and medical files. Cohen's kappa was used for intra- and inter-observer agreement calculation. Diagnostic properties were calculated against the gold standard reading. A total of 228 entheses were evaluated. Gold standard analysis diagnosed 83 (36 %) enthesitis lesions. Intra-reader reliability for the experienced reader was significantly (p = 0.0001) higher in the T1+Gd images compared to the STIR images (hamstring: k = 0.84/0.45, GM: k = 0.84/0.47). Sensitivity and specificity increased from 0.74/0.8 to 0.87/0.9 in the STIR images and T1+Gd sequences. Intra-reader reliability for the inexperienced reader was lower (p > 0.05). Evidence showing that contrast material improves the reliability, sensitivity, and specificity of detecting enthesitis supports its use in this setting. (orig.)

  13. Assessment of ameloblastomas using MRI and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Asaumi, Jun-ichi; Hisatomi, Miki; Yanagi, Yoshinobu; Matsuzaki, Hidenobu; Choi, Yong Suk; Kawai, Noriko; Konouchi, Hironobu; Kishi, Kanji

    2005-01-01

    We retrospectively evaluated magnetic resonance images (MRI) and dynamic contrast-enhanced MRI (DCE-MRI) of ameloblastomas. MRI and DCE-MRI were performed for 10 ameloblastomas. We obtained the following results from the MRI and DCE-MRI. (a) Ameloblastomas can be divided into solid and cystic portions on the basis of MR signal intensities. (b) Ameloblastomas show a predilection for intermediate signal intensity on T1WI, high signal intensity on T2WI, and well enhancement in the solid portion; they also show a homogeneous intermediate signal intensity on T1WI and homogeneous high signal intensity on T2WI, and no enhancement in the cystic portion. (c) The mural nodule or thick wall can be detected in ameloblastomas lesions. (d) CI curves of ameloblastomas show two patterns: the first pattern increases, reaches a plateau at 100-300 s, then sustains the plateau or decreases gradually to 600-900 s, while the other increases relatively rapidly, reaches a plateau at 90-120 s, then decreases relatively rapidly to 300 s, and decreases gradually thereafter. There was no difference in the CI curve patterns among primary and recurrent cases, a case with glandular odontogenic tumor in ameloblastoma or among histopathological types such as plexiform, follicular, mixed, desmoplastic, and unicystic type

  14. Contrast-enhanced magnetic resonance imaging for the detection of acute haemorrhagic necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Piironen, A.; Kivisaari, R.; Pitkaeranta, P.; Poutanen, V.P.; Laippala, P.; Laurila, P.; Kivisaari, L.

    1997-01-01

    Eleven piglets with haemorrhagic necrotizing pancreatitis and nine piglets with oedematous pancreatitis were imaged using a multi-breath-hold TurboFLASH (TR 6.5 ms, TE 3 ms, TI 300 ms, flip angle 8 , three slices) pre-excited T1-weighted sequence with an IV bolus injection of gadopentetate dimeglumine (Gd-DTPA, 0.3 mmol/kg) as a contrast agent to show dynamic contrast enhancement of the pancreas by MRI. All piglets were imaged according to the same protocol before inducing the disease. Following the IV Gd-DTPA bolus, time-enhancement curve of the pancreas during haemorrhagic necrotizing pancreatitis was significantly lower than during oedematous pancreatitis. The enhancement curves for the healthy piglets and piglets with oedematous pancreatitis did not differ significantly. Each piglet served as its own control. Because the results of this initial study are similar to those obtained with contrast-enhanced CT, we conclude that our results may encourage further clinical trials, and contrast-enhanced dynamic MRI may be an alternative to the established method of CT for diagnosing acute haemorrhagic necrotizing pancreatitis. (orig.). With 3 figs

  15. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer

    International Nuclear Information System (INIS)

    Fischer, U.; Kopka, L.; Brinck, U.; Korabiowska, M.; Schauer, A.; Grabbe, E.

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1,c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes. (orig.). With 5 tabs

  16. Magnetic resonance imaging of urinary bladder carcinoma: tumor staging and gadolinium contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Doringer, E.; Joos, H.; Forstner, R.; Schmoller, H.

    1992-01-01

    Forty-nine patients with urinary bladder carcinomas underwent pre-operative examinations using magnetic resonance (MR) imaging. The results of the MR examinations were correlated with the clinical-pathological findings following transurethral resection (TUR) and bimanual palpation (n = 47) or radical cystectomy (n = 2). The results of pre-contrast MR tumor staging (T1, T2), viewing stages Tis-T2 collectively, and subsequent to separate assessments of stages T3b-T4b, were correct 76.6% of the time. Gadolinium-DTPA (Gd-DTPA) contrast-enhanced examinations (pre-contrast T1 and after Gd-DTPA) showed a staging accuracy rate of 85.7%. T2-weighted images did not indicate any advantage when compared to T1-weighted images following Gd-DTPA. The signal intensity ratios of tumor/fat and tumor/muscle tissue were measured on T1-weighted pre-contrast images and following Gd-DTPA and then evaluated statistically, whereby the increased tumor signal intensity was statistically significant (Wilcoxon test, P < 0.01). Due to the relatively short examination time needed for T1-weighted images and the specific tumor enhancement, the administration of Gd-DTPA proves valuable in the diagnosis of bladder carcinomas. T2-weighted images are not necessary. (orig.)

  17. The pelvis after surgery and radio-chemotherapy for rectal cancer studied with Gd-DTPA-enhanced fast dynamic MR imaging

    International Nuclear Information System (INIS)

    Blomqvist, L.; Fransson, P.; Hindmarsh, T.

    1998-01-01

    The aim of this work was to study the gadolinium-enhancement of malignant and benign pathology in the pelvis after surgery for rectal cancer. Thirty patients with either local recurrence (n = 17) or benign changes related to treatment for rectal cancer (n = 13) were studied with pelvic MR imaging. T2-weighted fast spin-echo as well as T1-weighted spin- or gradient-echo imaging before and after intravenous contrast was performed and referred to as contrast-enhanced MRI (CEMRI). In addition, between the pre- and postcontrast images, dynamic contrast-enhanced MRI (DCEMRI) was performed using a single-slice, multi-phase, contrast-enhanced T1-weighted fast spoiled gradient-echo sequence. The time between the start of contrast injection to the beginning of enhancement, the duration and rate of enhancement as well as enhancement amplitude were recorded. The data were compared with the clinical diagnosis according to biopsy in 8 patients and surgery in 6 patients. In the remaining 16 patients, the clinical diagnosis was obtained by clinical or radiological follow-up. DCEMRI did not improve the diagnostic information compared with CEMRI. None of the examined parameters were found to help discriminating malignant from benign changes. Characterisation of lesions in the pelvis after rectal cancer surgery was not improved by a dynamic gadolinium-enhanced sequence. (orig.)

  18. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  19. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  20. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.

    Science.gov (United States)

    Lüdemann, Lutz; Nafz, Benno; Elsner, Franz; Grosse-Siestrup, Christian; Meissler, Michael; Kaufels, Nicola; Rehbein, Hagen; Persson, Pontus B; Michaely, Henrik J; Lengsfeld, Philipp; Voth, Matthias; Gutberlet, Matthias

    2009-03-01

    To evaluate for the first time in an animal model the possibility of absolute regional quantification of renal medullary and cortical perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a blood pool contrast agent. A total of 18 adult female pigs (age, 16-22 weeks; body weight, 45-65 kg; no dietary restrictions) were investigated by DCE-MRI. Absolute renal blood flow (RBF) measured by an ultrasound transit time flow probe around the renal vein was used as the standard of reference. An inflatable stainless cuff placed around the renal artery near its origin from the abdominal aorta was used to reduce RBF to 60%, 40%, and 20% of the baseline flow. The last measurement was performed with the cuff fully reopened. Absolute RBF values during these 4 perfusion states were compared with the results of DCE-MRI performed on a 1.5-T scanner with an 8-channel phased-array surface coil. All scans were acquired in breath-hold technique in the coronal plane using a field of view of 460 mm.Each dynamic scan commenced with a set of five 3D T1-weighted gradient echo sequences with different flip angles (alpha = 2 degrees, 5 degrees, 10 degrees, 20 degrees, 30 degrees): TE, 0.88 milliseconds; TR, 2.65 milliseconds; slice thickness, 8.8 mm for 4 slices; acquisition matrix, 128 x 128; and acquisitions, 4. These data served to calculate 3D intrinsic longitudinal relaxation rate maps (R10) and magnetization (M0). Immediately after these images, the dynamic 3D T1-weighted gradient echo images were acquired with the same parameters and a constant alpha = 30 degrees, half Fourier, 1 acquisition, 64 frames, a time interval of 1.65 seconds between each frame, and a total duration of 105.6. Three milliliters of an albumin-binding blood pool contrast agent (0.25 mmol/mL gadofosveset trisodium, Vasovist, Bayer Schering Pharma AG, Berlin, Germany) was injected at a rate of 3 mL/s. Perfusion was calculated using the arterial input function from the aorta, which was

  1. Quantification of traumatic meningeal injury using dynamic contrast enhanced (DCE) fluid-attenuated inversion recovery (FLAIR) imaging

    Science.gov (United States)

    Castro, Marcelo A.; Williford, Joshua P.; Cota, Martin R.; MacLaren, Judy M.; Dardzinski, Bernard J.; Latour, Lawrence L.; Pham, Dzung L.; Butman, John A.

    2016-03-01

    Traumatic meningeal injury is a novel imaging marker of traumatic brain injury, which appears as enhancement of the dura on post-contrast T2-weighted FLAIR images, and is likely associated with inflammation of the meninges. Dynamic Contrast Enhanced MRI provides a better discrimination of abnormally perfused regions. A method to properly identify those regions is presented. Images of seventeen patients scanned within 96 hours of head injury with positive traumatic meningeal injury were normalized and aligned. The difference between the pre- and last post-contrast acquisitions was segmented and voxels in the higher class were spatially clustered. Spatial and morphological descriptors were used to identify the regions of enhancement: a) centroid; b) distance to the brain mask from external voxels; c) distance from internal voxels; d) size; e) shape. The method properly identified thirteen regions among all patients. The method failed in one case due to the presence of a large brain lesion that altered the mask boundaries. Most false detections were correctly rejected resulting in a sensitivity and specificity of 92.9% and 93.6%, respectively.

  2. Self-organizing neural networks for automatic detection and classification of contrast-enhancing lesions in dynamic MR-mammography

    International Nuclear Information System (INIS)

    Vomweg, T.W.; Teifke, A.; Kauczor, H.U.; Achenbach, T.; Rieker, O.; Schreiber, W.G.; Heitmann, K.R.; Beier, T.; Thelen, M.

    2005-01-01

    Purpose: Investigation and statistical evaluation of 'Self-Organizing Maps', a special type of neural networks in the field of artificial intelligence, classifying contrast enhancing lesions in dynamic MR-mammography. Material and Methods: 176 investigations with proven histology after core biopsy or operation were randomly divided into two groups. Several Self-Organizing Maps were trained by investigations of the first group to detect and classify contrast enhancing lesions in dynamic MR-mammography. Each single pixel's signal/time curve of all patients within the second group was analyzed by the Self-Organizing Maps. The likelihood of malignancy was visualized by color overlays on the MR-images. At last assessment of contrast-enhancing lesions by each different network was rated visually and evaluated statistically. Results: A well balanced neural network achieved a sensitivity of 90.5% and a specificity of 72.2% in predicting malignancy of 88 enhancing lesions. Detailed analysis of false-positive results revealed that every second fibroadenoma showed a 'typical malignant' signal/time curve without any chance to differentiate between fibroadenomas and malignant tissue regarding contrast enhancement alone; but this special group of lesions was represented by a well-defined area of the Self-Organizing Map. Discussion: Self-Organizing Maps are capable of classifying a dynamic signal/time curve as 'typical benign' or 'typical malignant'. Therefore, they can be used as second opinion. In view of the now known localization of fibroadenomas enhancing like malignant tumors at the Self-Organizing Map, these lesions could be passed to further analysis by additional post-processing elements (e.g., based on T2-weighted series or morphology analysis) in the future. (orig.)

  3. T2-enhanced tensor diffusion trace-weighted image in the detection of hyper-acute cerebral infarction: Comparison with isotropic diffusion-weighted image

    International Nuclear Information System (INIS)

    Chou, M.-C.; Tzeng, W.-S.; Chung, H.-W.; Wang, C.-Y.; Liu, H.-S.; Juan, C.-J.; Lo, C.-P.; Hsueh, C.-J.; Chen, C.-Y.

    2010-01-01

    Background and purpose: Although isotropic diffusion-weighted imaging (isoDWI) is very sensitive to the detection of acute ischemic stroke, it may occasionally show diffusion negative result in hyper-acute stroke. We hypothesize that high diffusion contrast diffusion trace-weighted image with enhanced T2 may improve stroke lesion conspicuity. Methods: Five hyper acute stroke patients (M:F = 0:5, average age = 61.8 ± 20.5 y/o) and 16 acute stroke patients (M:F = 11:5, average age = 67.7 ± 12 y/o) were examined six-direction tensor DWIs at b = 707 s/mm 2 . Three different diffusion-weighted images, including isotropic (isoDWI), diffusion trace-weighted image (trDWI) and T2-enhanced diffusion trace-weighted image (T2E t rDWI), were generated. Normalized lesion-to-normal ratio (nLNR) and contrast-to-noise ratio (CNR) of three diffusion images were calculated from each patient and statistically compared. Results: The trDWI shows better nLNR than isoDWI on both hyper-acute and acute stroke lesions, whereas no significant improvement in CNR. Nevertheless, the T2E t rDWI has statistically superior CNR and nLNR than those of isoDWI and trDWI in both hyper-acute and acute stroke. Conclusions: We concluded that tensor diffusion trace-weighted image with T2 enhancement is more sensitive to stroke lesion detection, and can provide higher lesion conspicuity than the conventional isotropic DWI for early stroke lesion delineation without the need of high-b-value technique.

  4. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  5. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  6. Early biomarkers from dynamic contrast-enhanced magnetic resonance imaging to predict the response to antiangiogenic therapy in high-grade gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Piludu, Francesca; Vidiri, Antonello [Regina Elena National Cancer Institute, Radiology and Diagnostic Imaging Department, Rome (Italy); Marzi, Simona [Regina Elena National Cancer Institute, Medical Physics Laboratory, Rome (Italy); Pace, Andrea; Villani, Veronica [Regina Elena National Cancer Institute, Neurology Division, Rome (Italy); Fabi, Alessandra [Regina Elena National Cancer Institute, Oncology Department, Rome (Italy); Carapella, Carmine Maria [Regina Elena National Cancer Institute, Oncologic Surgery Department, Rome (Italy); Terrenato, Irene [Regina Elena National Cancer Institute, Biostatistics-Scientific Direction, Rome (Italy); Antenucci, Anna [Regina Elena National Cancer Institute, Clinical Pathology, Rome (Italy)

    2015-12-15

    The aim of this study is to investigate whether early changes in tumor volume and perfusion measurements derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) may predict response to antiangiogenic therapy in recurrent high-grade gliomas. Twenty-seven patients who received bevacizumab every 3 weeks were enrolled in the study. For each patient, three MRI scans were performed: at baseline, after the first dose, and after the fourth dose of bevacizumab. The entire tumor volume (V{sub tot}), as well as contrast-enhanced and noncontrast-enhanced tumor subvolumes (V{sub CE-T1} and V{sub NON-CE-T1}, respectively) were outlined using post-contrast T1-weighted images as a guide for the tumor location. Histogram analysis of normalized IAUGC (nIAUGC) and transfer constant K{sup trans} maps were performed. Each patient was classified as a responder patient if he/she had a partial response or a stable disease or as a nonresponder patient if he/she had progressive disease. Responding patients showed a larger reduction in V{sub NON-CE-T1} after a single dose, compared to nonresponding patients. Tumor subvolumes with increased values of nIAUGC and K{sup trans}, after a single dose, significantly differed between responders and nonresponders. The radiological response was found to be significantly associated to the clinical outcome. After a single dose, V{sub tot} was predictive of overall survival (OS), while V{sub CE-T1} showed a tendency of correlation with OS. Tumor subvolumes with increased nIAUGC and K{sup trans} showed the potential for improving the diagnostic accuracy of DCE. Early assessments of the entire tumor volume, including necrotic areas, may provide complementary information of tumor behavior in response to anti-VEGF therapies and is worth further investigation. (orig.)

  7. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  8. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  9. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rovira, A.; Alonso, J.; Cucurella, G.; Nos, C.; Tintore, M.; Pedraza, S.; Rio, J.; Montalban, X.

    1997-01-01

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs

  10. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  11. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  12. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Xiao, Hua-Feng; Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin; Lou, Xin; Gui, Qiu-Ping; Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan

    2015-01-01

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10 -3 mm 2 /s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  13. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hua-Feng [302 Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China); Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); Lou, Xin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); University of California, Department of Neurology, Los Angeles, CA (United States); Gui, Qiu-Ping [People' s Liberation Army General Hospital, Department of Pathology, Beijing (China); Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan [General Electric Healthcare (China) Co., Ltd., Beijing; Wang, Danny J.J. [University of California, Department of Neurology, Los Angeles, CA (United States)

    2015-12-15

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10{sup -3} mm{sup 2}/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  14. The role of dynamic contrast-enhanced and diffusion weighted magnetic resonance imaging in the female pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Sala, Evis, E-mail: es220@radiol.cam.ac.uk [University Department of Radiology, Box 218, Level 5, Addenbrooke' s Hospital, Hills Road, Cambridge CB2 0QQ (United Kingdom); Rockall, Andrea, E-mail: Andrea.Rockall@bartsandthelondon.nhs.uk [Department of Radiology, St Bartholomew' s Hospital, West Smithfield, London EC1A 7ED (United Kingdom); Rangarajan, Deepa, E-mail: rdrangarajan@googlemail.com [Department of Radiology, Box 218, Addenbrooke' s Hospital, Hills Road, Cambridge CB2 0QQ (United Kingdom); Kubik-Huch, Rahel A., E-mail: rahel.kubik@ksb.ch [Institute of Radiology, Department of Medical Services, Kantonsspital Baden Im Ergel, CH-5404 Baden (Switzerland)

    2010-12-15

    Functional imaging by means of dynamic multiphase contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion weighted magnetic resonance imaging (DW-MRI) is now part of the standard imaging protocols for evaluation of the female pelvis. DCE-MRI and DW-MRI are important MR imaging techniques which enable the radiologist to move from morphological to functional assessment of diseases of the female pelvis. This is mainly due to the limitations of morphologic imaging, particularly in lesion characterization, accurate lymph node staging, assessment of tumour response and inability to differentiate post-treatment changes from tumour recurrence. DCE-MRI improves the accuracy of T2WI in staging of endometrial cancer. It also helps differentiate tumour recurrence from radiation fibrosis in patients with cervical cancer. DCE-MRI improves characterization of cystic adnexal lesions and detection of small peritoneal implants in patients with ovarian cancer. DW-MRI is valuable in preoperative staging of patients with endometrial and cervical cancer, especially in detection of extra-uterine disease. It does increase reader's confidence for detection of recurrent disease in gynaecological malignancies and improves detection of small peritoneal implants in patients with ovarian cancer. In this review article we give an overview of both DCE-MRI and DW-MRI techniques, concentrating on their main clinical application in the female pelvis, and present a practical approach of the added value of these techniques according to the main pathological conditions, highlighting the pearls and pitfalls of each technique.

  15. Dynamic contrast-enhanced imaging of the wrist in rheumatoid arthritis: dedicated low-field (0.25-T) versus high-field (3.0-T) MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Wang, D.F.; Yeung, David K.W. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong, SAR (China); Shi, L. [The Chinese University of Hong Kong, Department of Medicine and Therapeutics, Division of Neurology, Hong Kong, SAR (China); Li, Edmund K.; Tam, L.S. [The Chinese University of Hong Kong, Department of Medicine, Division of Rheumatology, Prince Of Wales Hospital, Hong Kong, SAR (China)

    2015-08-15

    To compare the assessment of wrist synovitis severity, synovial volume and synovial perfusion parameters on a dedicated low-field (0.25-T) to that of a high-field (3-T) whole-body MR system in patients with rheumatoid arthritis (RA). Twenty-one patients (mean age 50.0 ± 9.8 years) with active RA were recruited prospectively. Dynamic contrast-enhanced MRI examination of the most severely affected wrist was performed at both 0.25 T and 3 T. Three MRI-derived parameters, synovitis severity (RAMRIS grade), synovial volume (ml{sup 3}) and synovial perfusion indices (maximum enhancement and enhancement slope), were compared. Comparing 0.25- and 3-T MRI, there was excellent agreement for semiquantitative assessment (r: 0.80, p < 0.00001) of synovitis (RAMRIS) as well as quantitative assessment (r: 0.94, p < 0.00001) of synovial volume. Good agreement for synovial Emax (r: 0.6, p = 0.002) and fair agreement (r: 0.5, p = 0.02) for synovial Eslope was found. Imaging of the RA wrist at 0.25 T yields excellent correlation with 3 T with regard to the synovitis activity score (RAMRIS) and synovial volume measurement. Fair to good correlation between low- (0.25-T) and high-field (3-T) MR systems was found for perfusion parameters, being better for Emax than for Eslope. (orig.)

  16. A comparison of Gd-BOPTA and Gd-DOTA for contrast-enhanced MRI of intracranial tumours

    International Nuclear Information System (INIS)

    Colosimo, C.; Knopp, M.V.; Barreau, X.; Gerardin, E.; Kirchin, M.A.; Guezenoc, F.; Lodemann, K.P.

    2004-01-01

    A two-centre intra-individual crossover study was performed in 23 patients with suspected high-grade glioma or metastases to assess and compare the safety and enhancement characteristics of two different MRI contrast media (gadobenate dimeglumine, Gd-BOPTA and gadoterate meglumine, Gd-DOTA) at equivalent doses of 0.1 mmol/kg body weight. T1-weighted spin-echo (SE) and T2-weighted fast SE images were obtained before and T1-weighted images 0, 2, 4, 6, 8 and 15 min after injection. T1-weighted images with magnetisation transfer contrast were acquired 12 min after injection. Qualitative assessment by blinded, off-site readers (reader 1: 19 patients; reader 2: 21) and on-site investigators (23) revealed significant (P ≤0.005) overall preference for Gd-BOPTA over Gd-DOTA for contrast enhancement (Gd-BOPTA preferred in 18, 15 and 18 cases; Gd-DOTA in 0, 1 and 1 and no preference in 1, 5 and 4; off-site readers 1 and 2, and on-site investigators, respectively). A similar significant preference for Gd-BOPTA was expressed by off-site readers and on-site investigators for lesion-to-brain contrast, lesion delineation, internal lesion structure, and overall image preference. Quantitative assessment by off-site readers revealed significantly (p<0.05) greater lesion enhancement with Gd-BOPTA than with Gd-DOTA at all times from 2 min after injection. (orig.)

  17. Biliary complications following orthotopic liver transplantation: May contrast-enhanced MR Cholangiography provide additional information?

    Directory of Open Access Journals (Sweden)

    Piero Boraschi

    2016-01-01

    Conclusions: Contrast-enhanced T1-weighted MR Cholangiography may improve the level of diagnostic confidence provided by conventional T2-weighted MR Cholangiography in the evaluation of biliary complications after orthotopic liver transplantation.

  18. Dynamic contrast-enhanced MRI improves accuracy for detecting focal splenic involvement in children and adolescents with Hodgkin disease

    International Nuclear Information System (INIS)

    Punwani, Shonit; Taylor, Stuart A.; Halligan, Steve; Cheung, King Kenneth; Skipper, Nicholas; Bell, Nichola; Humphries, Paul D.; Bainbridge, Alan; Groves, Ashley M.; Hain, Sharon F.; Ben-Haim, Simona; Shankar, Ananth; Daw, Stephen

    2013-01-01

    Accurate assessment of splenic disease is important for staging Hodgkin lymphoma. The purpose of this study was to assess T2-weighted imaging with and without dynamic contrast-enhanced (DCE) MRI for evaluation of splenic Hodgkin disease. Thirty-one children with Hodgkin lymphoma underwent whole-body T2-weighted MRI with supplementary DCE splenic imaging, and whole-body PET-CT before and following chemotherapy. Two experienced nuclear medicine physicians derived a PET-CT reference standard for splenic disease, augmented by follow-up imaging. Unaware of the PET-CT, two experienced radiologists independently evaluated MRI exercising a locked sequential read paradigm (T2-weighted then DCE review) and recorded the presence/absence of splenic disease at each stage. Performance of each radiologist was determined prior to and following review of DCE-MRI. Incorrect MRI findings were ascribed to reader (lesion present on MRI but missed by reader) or technical (lesion not present on MRI) error. Seven children had splenic disease. Sensitivity/specificity of both radiologists for the detection of splenic involvement using T2-weighted images alone was 57%/100% and increased to 100%/100% with DCE-MRI. There were three instances of technical error on T2-weighted imaging; all lesions were visible on DCE-MRI. T2-weighted imaging when complemented by DCE-MRI imaging may improve evaluation of Hodgkin disease splenic involvement. (orig.)

  19. Dynamic contrast-enhanced MRI improves accuracy for detecting focal splenic involvement in children and adolescents with Hodgkin disease

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College London Hospital, Department of Radiology, London (United Kingdom); Cheung, King Kenneth; Skipper, Nicholas [University College London, Centre for Medical Imaging, London (United Kingdom); Bell, Nichola; Humphries, Paul D. [University College London Hospital, Department of Radiology, London (United Kingdom); Bainbridge, Alan [University College London, Department of Medical Physics and Bioengineering, London (United Kingdom); Groves, Ashley M.; Hain, Sharon F.; Ben-Haim, Simona [University College Hospital, Institute of Nuclear Medicine, London (United Kingdom); Shankar, Ananth; Daw, Stephen [University College London Hospital, Department of Paediatrics, London (United Kingdom)

    2013-08-15

    Accurate assessment of splenic disease is important for staging Hodgkin lymphoma. The purpose of this study was to assess T2-weighted imaging with and without dynamic contrast-enhanced (DCE) MRI for evaluation of splenic Hodgkin disease. Thirty-one children with Hodgkin lymphoma underwent whole-body T2-weighted MRI with supplementary DCE splenic imaging, and whole-body PET-CT before and following chemotherapy. Two experienced nuclear medicine physicians derived a PET-CT reference standard for splenic disease, augmented by follow-up imaging. Unaware of the PET-CT, two experienced radiologists independently evaluated MRI exercising a locked sequential read paradigm (T2-weighted then DCE review) and recorded the presence/absence of splenic disease at each stage. Performance of each radiologist was determined prior to and following review of DCE-MRI. Incorrect MRI findings were ascribed to reader (lesion present on MRI but missed by reader) or technical (lesion not present on MRI) error. Seven children had splenic disease. Sensitivity/specificity of both radiologists for the detection of splenic involvement using T2-weighted images alone was 57%/100% and increased to 100%/100% with DCE-MRI. There were three instances of technical error on T2-weighted imaging; all lesions were visible on DCE-MRI. T2-weighted imaging when complemented by DCE-MRI imaging may improve evaluation of Hodgkin disease splenic involvement. (orig.)

  20. Pain following double-bundle anterior cruciate ligament reconstruction: Correlation with morphological graft findings and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Lin, Y.-C.; Mhuircheartaigh, J.N.; Cheung, Y.-C.; Juan, Y.-H.; Chiu, C.-H.; Yeh, W.-L.; Wu, J.S.

    2014-01-01

    Aim: To determine the relationship between knee pain following anterior cruciate ligament (ACL) graft placement with morphological graft findings and dynamic contrast enhancement as assessed at MRI. Material and methods: Following institutional review board approval, 37 consecutive patients with double-bundle ACL reconstruction were enrolled. Thirteen patients had pain and 24 were asymptomatic. Imaging was performed using a 1.5 T MRI machine an average of 7.6 months after surgery. Graft-related (increase signal intensity, abnormal orientation, discontinuity, cystic degeneration, anterior translation of lateral tibia, arthrofibrosis), and non-graft related causes of knee pain (meniscal tear, cartilage injury, loose bodies, and synovitis) were evaluated. During dynamic contrast enhancement analysis, peak enhancement (ePeak) was calculated by placing a region of interest at the osteoligamentous interface of each bundle. Student's t-test was used for continuous variables analysis and chi-square or Fisher's exact test was used for categorical variables analysis. Results: There was no difference between symptomatic and asymptomatic patients regarding morphological graft-related or non-graft-related causes of knee pain. For dynamic contrast enhancement analysis, symptomatic patients had significantly lower ePeak values than asymptomatic patients in the anteromedial (p = 0.008) and posterolateral (p = 0.001) bundles or when using the higher ePeak value in either bundle (p = 0.003). Conclusion: Morphological ACL graft findings as assessed at MRI could not be used to distinguish between symptomatic and asymptomatic patients. However, lower ePeak values had a significant association with knee pain. This may indicate poor neovascularization of the graft, potentially leading to graft failure. - Highlights: • Morphologic graft findings of MRI are poorly associated with knee pain. • Lower contrast enhancement values are significantly associated with knee pain

  1. Radiation necrosis of the optic chiasm, optic tract, hypothalamus, and upper pons after radiotherapy for pituitary adenoma, detected by gadolinium-enhanced, T1-weighted magnetic resonance imaging: Case report

    International Nuclear Information System (INIS)

    Tachibana, O.; Yamaguchi, N.; Yamashima, T.; Yamashita, J.

    1990-01-01

    A 26-year-old woman was treated for a prolactin secreting pituitary adenoma by surgery and radiotherapy (5860 rads). Fourteen months later, she developed right hemiparesis and dysarthria. A T1-weighted magnetic resonance imaging scan using gadolinium contrast showed a small, enhanced lesion in the upper pons. Seven months later, she had a sudden onset of loss of vision, and radiation optic neuropathy was diagnosed. A T1-weighted magnetic resonance imaging scan showed widespread gadolinium-enhanced lesions in the optic chiasm, optic tract, and hypothalamus. Magnetic resonance imaging is indispensable for the early diagnosis of radiation necrosis, which is not visualized by radiography or computed tomography

  2. Contrast-enhanced MR enterography as a stand-alone tool to evaluate Crohn's disease in a paediatric population

    International Nuclear Information System (INIS)

    Spieler, B.; Hindman, N.; Levy, J.; Zabrieski, K.; Sahlein, D.; Seuss, C.; Kim, S.

    2013-01-01

    Aim: To assess the performance of contrast-enhanced T1-weighted magnetic resonance imaging (MRI) alone in the evaluation of Crohn's disease in comparison to all magnetic resonance enterography (MRE) imaging sequences together in an attempt to suggest limitation of the number of overall unenhanced sequences need for the follow-up evaluation. Materials and methods: Twenty-five paediatric patients (mean age 14.1 ± 3.7 years, male = 12, female = 13) underwent MRE at 1.5 T for evaluation of Crohn's disease. Two radiologists reviewed only contrast-enhanced T1-weighted images in consensus on the first session. Whole images including unenhanced (steady-state free precession, single-shot fast spin-echo (HASTE), fat-suppressed T2-weighted) and contrast-enhanced T1-weighted sequences were reviewed in consensus during the second session with a 1 month interval, which was used as a reference standard. The readers evaluated the presence or absence of disease in 10 bowel segments in each patient. For the abnormal bowel segments, the readers then evaluated for active versus inactive disease and for the presence or absence of abscess. Sensitivity, specificity, and overall accuracy were calculated for detecting active inflammation. Results: There were 53/250 bowel segments with active inflammation using the reference standard imaging method. The sensitivity, specificity, and accuracy for diagnosing active inflammation using contrast-enhanced images alone were 83.3%, 86.9%, and 84.9%. In five of the false-positive cases of detecting abscess from contrast-enhanced imaging alone, absence of abscesses was confirmed on the non-fat-suppressed HASTE images. Conclusion: The number of MRE sequences in paediatric Crohn's patients can be decreased while maintaining diagnostic accuracy using contrast-enhanced T1 and non-fat-suppressed HASTE images

  3. Contrast-enhanced dynamic MR imaging of parasellar tumor using fast spin-echo sequence

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Ohue, Shiro; Ichikawa, Haruhisa; Saito, Masahiro; Sadamoto, Kazuhiko; Sakaki, Saburo; Miki, Hitoshi.

    1995-01-01

    We have applied a new dynamic MRI technique that uses a fast spin-echo sequence to parasellar tumors. This sequence has less susceptible effect and better spatial resolution than a gradient echo sequence, providing faster images than a short spin-echo sequence does. Image was obtained in the coronal or sagittal plane using a 1.5T clinical MRI system, and then, dynamic MR images were acquired every 10 to 20 sec after administration of Gd-DTPA (0.1 mmol/kg). The subjects were 12 patients (5 microadenomas, 5 macroadenomas and 2 Rathke's cleft cysts) and 5 normal volunteers. As for volunteers, the cavernous sinus, pituitary stalk and posterior pituitary gland were contrasted on the first image, followed by visualization of the proximal portion adjacent to the junction of the infundibulum and the anterior pituitary gland, and finally by contrasting the distal portion of the anterior pituitary gland. There was a difference with respect to tumor contrast between microadenomas and macroadenomas. In the case of the macroadenomas, the tumor was contrasted at the same time as, or faster than the anterior pituitary gland, while with the microadenomas the tumor was enhanced later than the anterior pituitary gland. No enhancement with contrast medium was seen in Rathke's cleft cysts. In addition, it was possible to differentiate a recurrent tumor from a piece of muscle placed at surgery since the images obtained by the fast spin-echo sequence were clearer than those obtained by gradient echo sequence. (author)

  4. Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.

    Science.gov (United States)

    Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack

    2017-09-01

    To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2  = 0.96 and P ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Improved evaluation of antivascular cancer therapy using constrained tracer-kinetic modeling for multi-agent dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Hectors, Stefanie; Jacobs, Igor; Lok, Jasper; Peters, Johannes; Bussink, Johan; Hoeben, Freek J. M.; Keizer, Henk; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias; Strijkers, Gustav

    2018-01-01

    Dynamic contrast-enhanced MRI (DCE-MRI) is a promising technique for assessing the response of tumor vasculature to anti-vascular therapies. Multi-agent DCE-MRI employs a combination of low and high molecular weight contrast agents, which potentially improves the accuracy of estimation of tumor

  6. Initial experience of correlating parameters of intravoxel incoherent motion and dynamic contrast-enhanced magnetic resonance imaging at 3.0 T in nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qian-Jun; Zhang, Shui-Xing; Chen, Wen-Bo; Liang, Long; Zhou, Zheng-Gen; Liu, Zai-Yi; Zeng, Qiong-Xin; Liang, Chang-Hong [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Qiu, Qian-Hui [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Otolaryngology, Guangzhou, Guangdong Province (China)

    2014-12-15

    To determine the correlation between intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters. Thirty-eight newly diagnosed NPC patients were prospectively enrolled. Diffusion-weighted images (DWI) at 13 b-values were acquired using a 3.0-T MRI system. IVIM parameters including the pure molecular diffusion (D), perfusion-related diffusion (D*), perfusion fraction (f), DCE-MRI parameters including maximum slope of increase (MSI), enhancement amplitude (EA) and enhancement ratio (ER) were calculated by two investigators independently. Intra- and interobserver agreement were evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Relationships between IVIM and DCE-MRI parameters were evaluated by calculation of Spearman's correlation coefficient. Intra- and interobserver reproducibility were excellent to relatively good (ICC = 0.887-0.997; narrow width of 95 % limits of agreement). The highest correlation was observed between f and EA (r = 0.633, P < 0.001), with a strong correlation between f and MSI (r = 0.598, P = 0.001). No correlation was observed between f and ER (r = -0.162; P = 0.421) or D* and DCE parameters (r = 0.125-0.307; P > 0.119). This study suggests IVIM perfusion imaging using 3.0-T MRI is feasible in NPC, and f correlates significantly with EA and MSI. (orig.)

  7. Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization

    International Nuclear Information System (INIS)

    Kubaska, Samantha; Sahani, Dushyant V.; Saini, Sanjay; Hahn, Peter F.; Halpern, Elkan

    2001-01-01

    AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRI) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC;n = 3), cholangiocharcinoma(n = 1) and focal nodular hyperplasia (FNH;n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging. Kubaska, S. et al. (2001)

  8. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  9. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.

    Science.gov (United States)

    Yoon, Jeong Hee; Yu, Mi Hye; Chang, Won; Park, Jin-Young; Nickel, Marcel Dominik; Son, Yohan; Kiefer, Berthold; Lee, Jeong Min

    2017-10-01

    The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI). This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs. In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013). Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T1WI for liver MRI in patients at high risk of breath-holding failure.

  10. Whole Body MRI at 3T with Quantitative Diffusion Weighted Imaging and Contrast-Enhanced Sequences for the Characterization of Peripheral Lesions in Patients with Neurofibromatosis Type 2 and Schwannomatosis

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Blakeley, Jaishri; Plotkin, Scott; Widemann, Brigitte; Jacobs, Michael A.

    2013-01-01

    Purpose. WB-MRI is mainly used for tumor detection and surveillance. The purpose of this study is to establish the feasibility of WB-MRI at 3T for lesion characterization, with DWI/ADC-mapping and contrast-enhanced sequences, in patients with neurofibromatosis type 2 (NF-2) and schwannomatosis. Materials and Methods. At 3T, WB-MRI was performed in 11 subjects (10 NF-2 and 1 schwannomatosis) with STIR, T1, contrast-enhanced T1, and DWI/ADC mapping (b = 50, 400, 800 s/mm 2 ). Two readers reviewed imaging for the presence and character of peripheral lesions. Lesion size and features (signal intensity, heterogeneity, enhancement characteristics, and ADC values) were recorded. Descriptive statistics were reported. Results. Twenty-three lesions were identified, with average size of 4.6 ± 2.8 cm. Lesions were characterized as tumors (21/23) or cysts (2/23) by contrast-enhancement properties (enhancement in tumors, no enhancement in cysts). On T1, tumors were homogeneously isointense (5/21) or hypointense (16/21); on STIR, tumors were hyperintense and homogeneous (10/21) or heterogeneous (11/21); on postcontrast T1, tumors enhanced homogeneously (14/21) or heterogeneously (7/21); on DWI, tumor ADC values were variable (range 0.8–2.7), suggesting variability in intrinsic tumor properties. Conclusion. WB-MRI with quantitative DWI and contrast-enhanced sequences at 3T is feasible and advances the utility of WB-MRI not only to include detection, but also to provide additional metrics for lesion characterization

  11. Influence of B{sub 1}-inhomogeneity on pharmacokinetic modeling of dynamic contrast-enhanced MRI: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Park, Bun Woo [Dept. of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Byung Se [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); and others

    2017-08-01

    To simulate the B1-inhomogeneity-induced variation of pharmacokinetic parameters on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). B1-inhomogeneity-induced flip angle (FA) variation was estimated in a phantom study. Monte Carlo simulation was performed to assess the FA-deviation-induced measurement error of the pre-contrast R1, contrast-enhancement ratio, Gd-concentration, and two-compartment pharmacokinetic parameters (Ktrans, ve, and vp). B1-inhomogeneity resulted in −23–5% fluctuations (95% confidence interval [CI] of % error) of FA. The 95% CIs of FA-dependent % errors in the gray matter and blood were as follows: −16.7–61.8% and −16.7–61.8% for the pre-contrast R1, −1.0–0.3% and −5.2–1.3% for the contrast-enhancement ratio, and −14.2–58.1% and −14.1–57.8% for the Gd-concentration, respectively. These resulted in −43.1–48.4% error for Ktrans, −32.3–48.6% error for the ve, and −43.2–48.6% error for vp. The pre-contrast R1 was more vulnerable to FA error than the contrast-enhancement ratio, and was therefore a significant cause of the Gd-concentration error. For example, a −10% FA error led to a 23.6% deviation in the pre-contrast R1, −0.4% in the contrast-enhancement ratio, and 23.6% in the Gd-concentration. In a simulated condition with a 3% FA error in a target lesion and a −10% FA error in a feeding vessel, the % errors of the pharmacokinetic parameters were −23.7% for Ktrans, −23.7% for ve, and −23.7% for vp. Even a small degree of B1-inhomogeneity can cause a significant error in the measurement of pharmacokinetic parameters on DCE-MRI, while the vulnerability of the pre-contrast R1 calculations to FA deviations is a significant cause of the miscalculation.

  12. Assessment of irradiated brain metastases using dynamic contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Almeida-Freitas, Daniela B.; Pinho, Marco C.; Otaduy, Maria C.G.; Costa Leite, Claudia da; Braga, Henrique F.; Meira-Freitas, Daniel

    2014-01-01

    The purpose of this study was to evaluate the effect of stereotactic radiosurgery (SRS) on cerebral metastases using the transfer constant (K trans ) assessed by dynamic contrast-enhanced (DCE) MRI. Furthermore, we aimed to evaluate the ability of K trans measurements to predict midterm tumor outcomes after SRS. The study received institutional review board approval, and informed consent was obtained from all subjects. Twenty-six adult patients with a total of 34 cerebral metastases underwent T1-weighted DCE MRI in a 1.5-T magnet at baseline (prior to SRS) and 4-8 weeks after treatment. Quantitative analysis of DCE MRI was performed by generating K trans parametric maps, and region-of-interest-based measurements were acquired for each metastasis. Conventional MRI was performed at least 16 weeks after SRS to assess midterm tumor outcome using volume variation. The mean (±SD) K trans value was 0.13 ± 0.11 min -1 at baseline and 0.08 ± 0.07 min -1 after 4-8 weeks post-treatment (p trans after SRS was predictive of tumor progression (hazard ratio = 1.50; 95 % CI = 1.16-1.70, p trans showed a sensitivity of 78 % and a specificity of 85 % for the prediction of progression at midterm follow-up. SRS was associated with a reduction of K trans values of the cerebral metastases in the early post-treatment period. Furthermore, K trans variation as assessed using DCE MRI may be helpful to predict midterm outcomes after SRS. (orig.)

  13. Dynamic contrast-enhanced magnetic resonance imaging of radiation therapy-induced microcirculation changes in rectal cancer

    International Nuclear Information System (INIS)

    Lussanet, Quido G. de; Backes, Walter H.; Griffioen, Arjan W.; Padhani, Anwar R.; Baeten, Coen I.; Baardwijk, Angela van; Lambin, Philippe; Beets, Geerard L.; Engelshoven, Jos van; Beets-Tan, Regina G.H.

    2005-01-01

    Purpose: Dynamic contrast-enhanced T1-weighted magnetic resonance imaging (DCE-MRI) allows noninvasive evaluation of tumor microvasculature characteristics. This study evaluated radiation therapy related microvascular changes in locally advanced rectal cancer by DCE-MRI and histology. Methods and Materials: Dynamic contrast-enhanced-MRI was performed in 17 patients with primary rectal cancer. Seven patients underwent 25 fractions of 1.8 Gy radiation therapy (RT) (long RT) before DCE-MRI and 10 did not. Of these 10, 3 patients underwent five fractions of 5 Gy RT (short RT) in the week before surgery. The RT treated and nontreated groups were compared in terms of endothelial transfer coefficient (K PS , measured by DCE-MRI), microvessel density (MVD) (scored by immunoreactivity to CD31 and CD34), and tumor cell and endothelial cell proliferation (scored by immunoreactivity to Ki67). Results: Tumor K PS was 77% (p = 0.03) lower in the RT-treated group. Histogram analyses showed that RT reduced both magnitude and intratumor heterogeneity of K PS (p = 0.01). MVD was significantly lower (37%, p 0.03) in tumors treated with long RT than in nonirradiated tumors, but this was not the case with short RT. Endothelial cell proliferation was reduced with short RT (81%, p = 0.02) just before surgery, but not with long RT (p > 0.8). Tumor cell proliferation was reduced with both long (57%, p PS values showed significant radiation therapy related reductions in microvessel blood flow in locally advanced rectal cancer. These findings may be useful in evaluating effects of radiation combination therapies (e.g., chemoradiation or RT combined with antiangiogenesis therapy), to account for effects of RT alone

  14. Diffusion-weighted and dynamic contrast-enhanced imaging as markers of clinical behavior in children with optic pathway glioma

    International Nuclear Information System (INIS)

    Jost, Sarah C.; Ackerman, Joseph W.; Garbow, Joel R.; Manwaring, Linda P.; Gutmann, David H.; McKinstry, Robert C.

    2008-01-01

    Optic pathway gliomas (OPGs) are common pediatric brain tumors that pose significant clinical challenges with regard to predicting which tumors are likely to become symptomatic and require treatment. These tumors can arise sporadically or in the context of the inherited cancer predisposition syndrome neurofibromatosis type 1 (NF1). Few studies have suggested biological or imaging markers that predict the clinical course of this disease. In this cross-sectional study, we hypothesized that the clinical behavior of OPGs in children can be differentiated by diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI. A total of 27 children with OPG were studied using DW and DCE MRI protocols. Diffusivity and permeability were calculated and correlated with the clinical behavior the OPG. Mean diffusivity values of 1.39 μm 2 /ms and mean permeability values of 2.10 ml/min per 100 cm 3 of tissue were measured. Clinically aggressive OPGs had significantly higher mean permeability values (P = 0.05) than clinically stable tumors. In addition, there was a strong correlation between clinical aggressiveness and the absence of NF1 (P < 0.01). These results suggest that DCE MRI might be a useful biomarker for clinically aggressive OPG, which should be confirmed in larger prospective longitudinal studies. (orig.)

  15. Perbedaan Intensitas Penyengatan Meningeal Hasil MRI antara Sekuens T2 FLAIR Post Contrast dan T1WI Post Contrast Gadolinium-DTPA dalam Mendeteksi Penyangatan Meningeal pada Kasus Meningitis Tuberkulosis

    Directory of Open Access Journals (Sweden)

    Arie Hendarin

    2017-09-01

    Full Text Available Diagnosis meningitis TB terutama pada kasus possible dan probable sulit ditegakkan. Pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA adalah modalitas radiologi yang paling sensitif untuk membantu mendiagnosis penyakit ini. Penyangatan meningeal di daerah basal merupakan gambaran MRI yang paling banyak ditemukan pada meningitis TB. Tujuan penelitian ini adalah mengetahui perbedaan peningkatan intensitas sinyal meningen sekuens T2-FLAIR dengan T1WI pada pasien meningitis tuberkulosis menggunakan pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA di RSUP Dr. Hasan Sadikin Bandung pada bulan Januari 2015–Juni 2016. Subjek penelitian sebanyak 21 orang dengan meningitis TB dilakukan pemeriksaan MRI kepala dengan kontras Gadolinium-DTPA. Analisis statistik komparatif dilakukan untuk menguji perbedaan peningkatan intensitas sinyal meningen sekuens T2-FLAIR post contrast dengan T1WI post contrast. Hasil penelitian menujukkan rerata peningkatan intensitas sinyal meningen sekuen T2-FLAIR (∆T2-FLAIR sebesar 360,59±182,19 aμ sedangkan T1WI (∆T1WI sebesar 126,47±72,57 aμ. Hasil uji statistik menggunakan uji T pada derajat kepercayaan 95% menunjukkan perbedaan yang bermakna ∆T2-FLAIR dengan ∆T1WI pada nilai p=0,000. Sebagai simpulan didapatkan peningkatan intensitas sinyal meningen sekuens T2-FLAIR post contrast lebih besar daripada T1WI post contrast pada kasus meningitis TB.  [MKB. 2017;49(3:172–78] Kata kunci: Meningitis tuberkulosis, MRI sekuens T1WI dan T2-FLAIR, penyangatan meningeal Difference between Gadolinium-DTPA Enhanced T2 FLAIR Sequence and T1WI Sequence MRI in Detecting Meningeal Enhancement in Tuberculous Meningitis The diagnosis of TB meningitis, especially in possible and probable cases, is difficult. Contrast-enhanced MRI of the head with Gadolinium-DTPA is the most sensitive imaging modality that supports diagnosis of this disease. The most common presentation of TB meningitis in MRI is basal meningeal enhancement

  16. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  17. Dynamic contrast-enhanced 3-T magnetic resonance imaging: a method for quantifying disease activity in early polyarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Navalho, Marcio [Faculdade de Medicina da Universidade de Lisboa, Rheumatology Research Unit, Instituto de Medicina Molecular, Lisbon (Portugal); Hospital da Luz, Radiology Department, Lisbon (Portugal); Hospital da Luz, Centro de Imagiologia, Lisbon (Portugal); Resende, Catarina [Hospital da Luz, Rheumatology Department, Lisbon (Portugal); Hospital de Santa Maria, Rheumatology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal); Rodrigues, Ana Maria; Fonseca, Joao Eurico; Canhao, Helena [Faculdade de Medicina da Universidade de Lisboa, Rheumatology Research Unit, Instituto de Medicina Molecular, Lisbon (Portugal); Hospital de Santa Maria, Rheumatology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal); Gaspar, Augusto [Hospital da Luz, Radiology Department, Lisbon (Portugal); Campos, Jorge [Hospital de Santa Maria, Radiology Department, Centro Hospitalar de Lisboa Norte, EPE, Lisbon (Portugal)

    2012-01-15

    To determine whether measurement of synovial enhancement and thickness quantification parameters with 3.0-Tesla magnetic resonance imaging (3-T MRI) can reliably quantify disease activity in patients with early polyarthritis. Eighteen patients (16 women, 2 men; mean age 46 years) with early polyarthritis with less than 12 months of symptoms were included. MRI examination using 3-T device was performed by a new approach including both wrists and hands simultaneously in the examination field-of-view. MRI scoring of disease activity included quantification of synovial enhancement with simple measurements such as rate of early enhancement (REE; REE{sub 57} = S{sub 57}/S{sub 200}, where S{sub 57} and S{sub 200} are the signal intensities 57 s and 200 s after gadolinium injection) and rate of relative enhancement (RE; RE = S{sub 200} - S{sub 0}). Both wrists and hands were scored according to the Rheumatoid Arthritis MRI Scoring System (RAMRIS) for synovitis. Disease activity was clinically assessed by the 28-joint Disease Activity Score (DAS28). DAS28 score was strongly correlated with RE (r = 0.8331, p < 0.0001), REE (r = 0.8112, p < 0.0001), and RAMRIS score for synovitis (r = 0.7659, p < 0.0002). An REE score above 0.778 accurately identified patients with clinically active disease (sensitivity 92%; specificity 67%; p < 0.05). A statistically significant difference was observed in the RE, REE, and RAMRIS scores for synovitis between patients with active and inactive disease (p < 0.05). Our findings support the use of 3-T dynamic contrast-enhanced MRI for precise quantification of disease activity and for discriminating active disease from inactive disease in early polyarthritis. (orig.)

  18. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanharawi, Imane El; Tzarouchi, Loukia [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Cardoen, Liesbeth [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude [Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Hopital Robert Debre, APHP, Service d' Endocrinologie Pediatrique, Paris (France); Elmaleh-Berges, Monique [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Alison, Marianne [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France)

    2017-05-15

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting. (orig.)

  19. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis.

    Science.gov (United States)

    El Sanharawi, Imane; Tzarouchi, Loukia; Cardoen, Liesbeth; Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude; Elmaleh-Berges, Monique; Alison, Marianne

    2017-05-01

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting.

  20. Evaluation of renal function with dynamic MRI-T2-weighted gradient echo technique

    International Nuclear Information System (INIS)

    Kato, Katsuya

    1995-01-01

    To evaluate the usefulness of dynamic MRI of kidneys in healthy volunteers and patients with different 24-hour creatinine clearance (Ccr) levels, a dynamic study that employed the T2 weighted gradient echo technique (FLASH: TR/TE=34/25 msec, flip angle= 20 degrees) with single images during breathhold was performed on 10 healthy volunteers and 35 patients, all examined for the Ccr and suspected of having renal parenchymal disease after a phantom study. T1-weighted and dynamic MR imagings were obtained with a 1.5T imager. I analyzed the time-intensity curve of renal cortex and medulla, and defined a cortex decreased ratio (CDR) and medulla decreased ratio (MDR) in comparison with the Ccr. The cortico-medullary difference ratio (CMDR) of T1WI was also compared with the Ccr. The parameters of the T2 dynamic MRI study (CDR, MDR) better correlated with the Ccr than CMDR. Renal function can be quantitatively evaluated with the T2 dynamic MRI and there is a possibility that we can qualitatively evaluate the renal dysfunction and estimate its cause. (author)

  1. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis; Resonancia magnetica con contraste y transferencia de magnetizacion en el estudio seriado de pacientes con esclerosis multiple

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, A; Alonso, J; Cucurella, G; Nos, C; Tintore, M; Pedraza, S; Rio, J; Montalban, X [Hospital General i Universitari Vall d` Hebron. Barcelona (Spain)

    1998-12-31

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs.

  2. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    International Nuclear Information System (INIS)

    Yoshino, Ayako

    1998-01-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds (ΔRT2) was calculated by the following equation: ΔRT2 = (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  3. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, Ayako [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-07-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds ({Delta}RT2) was calculated by the following equation: {Delta}RT2 (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  4. Dynamic contrast-enhanced CT appearances of the intraductal papillary neoplasms of the bile duct

    International Nuclear Information System (INIS)

    Song Fengxiang; Zhou Jianjun; Zeng Mengsu; Zhou Kangrong; Ding Yuqin; He Deming; Shi Yuxin; Zhou Jun

    2013-01-01

    Objective: To analyze the dynamic contrast-enhanced CT appearances of intraductal papillary neoplasms of the bile duct and improve its diagnostic accuracy. Methods: Sixteen patients with intraductal papillary neoplasms of the bile duct confirmed histopathologically after surgical operation underwent dynamic contrast-enhanced multi-detector row CT scans. All imaging data were reviewed and analyzed retrospectively in correlation with surgical and pathological findings. CT values of 38 well-visualized lesions in 12 of the 16 patients at the pre-contrast phase, arterial phase and venous phase were measured. Four of the 12 patients with 17 lesions had benign tumors, and 8 of the 12 patients with 21 lesions had malignant tumors. Comparisons of CT values at the three phases between the two groups were carried out using independent sample t test. The bile CT values were measured in these 12 cases, 40 normal volunteers, and 40 subjects with bile duct stones, and the Wilcoxon signed-rank test was applied to compare the bile CT values between tumor group and the normal group and between tumor group and the bile duct stone group. The diameters of the bile ducts proximal to and distal to tumors were also measured, and Fisher exact method was carried to analyze the data. Results: Lesions located at the left lobe in 8 out of the 16 patients, the right lobe in 1 case, both the left and right lobes in 1 case, the hepatic hilum in 1 case, the common bile duct in 3 cases, and both the right lobe and the common bile duct in 2 cases. Eleven lesions appeared as papillary masses, 3 as flat masses, 1 as mixed papillary and flat masses. In one case, tumor mass could not be definitely visualized, and only dilated bile ducts and stones were demonstrated. The mean CT values of the benign tumors were (25.8 ± 8.0), (37.7 ± 10.3) and (51.7 ± 17.1) HU respectively at pre-contrast phase, arterial phase, and venous phase, and the malignant tumors were (38.4 ± 10.2), (56.6 ± 18.0) and (68.4

  5. Fast magnetic resonance fingerprinting for dynamic contrast-enhanced studies in mice.

    Science.gov (United States)

    Gu, Yuning; Wang, Charlie Y; Anderson, Christian E; Liu, Yuchi; Hu, He; Johansen, Mette L; Ma, Dan; Jiang, Yun; Ramos-Estebanez, Ciro; Brady-Kalnay, Susann; Griswold, Mark A; Flask, Chris A; Yu, Xin

    2018-05-09

    The goal of this study was to develop a fast MR fingerprinting (MRF) method for simultaneous T 1 and T 2 mapping in DCE-MRI studies in mice. The MRF sequences based on balanced SSFP and fast imaging with steady-state precession were implemented and evaluated on a 7T preclinical scanner. The readout used a zeroth-moment-compensated variable-density spiral trajectory that fully sampled the entire k-space and the inner 10 × 10 k-space with 48 and 4 interleaves, respectively. In vitro and in vivo studies of mouse brain were performed to evaluate the accuracy of MRF measurements with both fully sampled and undersampled data. The application of MRF to dynamic T 1 and T 2 mapping in DCE-MRI studies were demonstrated in a mouse model of heterotopic glioblastoma using gadolinium-based and dysprosium-based contrast agents. The T 1 and T 2 measurements in phantom showed strong agreement between the MRF and the conventional methods. The MRF with spiral encoding allowed up to 8-fold undersampling without loss of measurement accuracy. This enabled simultaneous T 1 and T 2 mapping with 2-minute temporal resolution in DCE-MRI studies. Magnetic resonance fingerprinting provides the opportunity for dynamic quantification of contrast agent distribution in preclinical tumor models on high-field MRI scanners. © 2018 International Society for Magnetic Resonance in Medicine.

  6. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    International Nuclear Information System (INIS)

    Gehl, H.B.; Bourne, M.; Grazioli, L.; Moeller, A.; Lodemann, K.P.

    2001-01-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  7. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, H.B. [Inst. of Diagnostic Radiology, Medical Univ. of Luebeck (Germany); Bourne, M. [Dept. of Radiology, Univ. Hospital of Wales, Cardiff (United Kingdom); Grazioli, L. [Dept. of Radiology, Univ. of Brescia (Italy); Moeller, A. [MEDIDATA GmbH, Konstanz (Germany); Lodemann, K.P. [BRACCO-BYK GULDEN GmbH, Konstanz (Germany)

    2001-02-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  8. Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle

    Energy Technology Data Exchange (ETDEWEB)

    Nicolato, Elena; Farace, Paolo; Asperio, Roberto M; Marzola, Pasquina; Lunati, Ernesto; Sbarbati, Andrea; Osculati, Francesco [Dipartimento di Scienze Morfologico-Biomediche, Sezione di Anatomia ed Istologia, Università di Verona, Verona, I-37194 (Italy)

    2002-06-05

    Studies about capillarity of the aged muscle provided conflicting results and no data are currently available about the magnetic resonance imaging (MRI) in vivo characteristics of the microvascular bed in aged rats. We have studied age-related modifications of the skeletal muscle by in vivo T2-relaxometry and dynamic contrast-enhanced magnetic resonance imaging (CE-MRI) at high field intensity (4.7 T). The aim of the work was to test the hypothesis that the ageing process involves microvessels in skeletal muscle. The study was performed in 4-month-old (n = 6) and 20-month-old (n = 6) rats. At MRI examination, the relaxation time T2 of the gastrocnemius muscle showed no significant difference between these two groups. The kinetic of contrast penetration in the tissue showed that in 4-month-old rats the enhancement values of the signal intensity at different time-points were significantly higher than those found in senescent rats. The reported finding suggests that there is a modification of the microcirculatory function in skeletal muscle of aged rats. This work also demonstrates that CE-MRI allows for an in vivo quantification of the multiple biological processes involving the skeletal muscle during aging. Therefore, CE-MRI could represent a further tool for the follow up of tissue modification and therapeutic intervention both in patients with sarcopenia and in experimental models of this pathology.

  9. Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle

    International Nuclear Information System (INIS)

    Nicolato, Elena; Farace, Paolo; Asperio, Roberto M; Marzola, Pasquina; Lunati, Ernesto; Sbarbati, Andrea; Osculati, Francesco

    2002-01-01

    Studies about capillarity of the aged muscle provided conflicting results and no data are currently available about the magnetic resonance imaging (MRI) in vivo characteristics of the microvascular bed in aged rats. We have studied age-related modifications of the skeletal muscle by in vivo T2-relaxometry and dynamic contrast-enhanced magnetic resonance imaging (CE-MRI) at high field intensity (4.7 T). The aim of the work was to test the hypothesis that the ageing process involves microvessels in skeletal muscle. The study was performed in 4-month-old (n = 6) and 20-month-old (n = 6) rats. At MRI examination, the relaxation time T2 of the gastrocnemius muscle showed no significant difference between these two groups. The kinetic of contrast penetration in the tissue showed that in 4-month-old rats the enhancement values of the signal intensity at different time-points were significantly higher than those found in senescent rats. The reported finding suggests that there is a modification of the microcirculatory function in skeletal muscle of aged rats. This work also demonstrates that CE-MRI allows for an in vivo quantification of the multiple biological processes involving the skeletal muscle during aging. Therefore, CE-MRI could represent a further tool for the follow up of tissue modification and therapeutic intervention both in patients with sarcopenia and in experimental models of this pathology

  10. Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Miyake, Mototaka; Sakurada, Aine; Arai, Yasuaki; Tsurusaki, Masakatsu; Sugimura, Kazuro

    2010-01-01

    To prospectively compare the diagnostic performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging at 3.0 T and 1.5 T for detection of hepatic metastases. A total of 28 patients (18 men, 10 women; mean age, 61 years) with 80 hepatic metastases were prospectively examined by SPIO-enhanced MR imaging at 3.0 T and 1.5 T. T1-weighted gradient-recalled-echo (GRE) images, T2*-weighted GRE images and T2-weighted fast spin-echo (SE) images were acquired. The tumour-to-liver contrast-to-noise ratio (CNR) of the lesions was calculated. Three observers independently reviewed each image. Image artefacts and overall image quality were analysed, sensitivity and positive predictive value for the detection of hepatic metastases were calculated, and diagnostic accuracy using the receiver-operating characteristics (ROC) method was evaluated. The tumour-to-liver CNRs were significantly higher at 3.0 T. Chemical shift and motion artefact were more severe, and overall image quality was worse on T2-weighted fast SE images at 3.0 T. Overall image quality of the two systems was similar on T1-weighted GRE images and T2*-weighted GRE images. Sensitivity and area under the ROC curve for the 3.0-T image sets were significantly higher. SPIO-enhanced MR imaging at 3.0 T provided better diagnostic performance for detection of hepatic metastases than 1.5 T. (orig.)

  11. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    International Nuclear Information System (INIS)

    Server, Andres; Nakstad, Per H.; Orheim, Tone E.D.; Graff, Bjoern A.; Josefsen, Roger; Kumar, Theresa

    2011-01-01

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  12. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Server, Andres; Nakstad, Per H. [Oslo University Hospital-Ullevaal, Section of Neuroradiology, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Oslo (Norway); Orheim, Tone E.D. [Oslo University Hospital, Interventional Centre, Oslo (Norway); Graff, Bjoern A. [Oslo University Hospital-Ullevaal, Department of Radiology and Nuclear Medicine, Oslo (Norway); Josefsen, Roger [Oslo University Hospital-Ullevaal, Department of Neurosurgery, Oslo (Norway); Kumar, Theresa [Oslo University Hospital-Ullevaal, Department of Pathology, Oslo (Norway)

    2011-05-15

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  13. Hepatocellular carcinoma. Comparison between gadolinium and ironoxide enhanced MR imaging

    International Nuclear Information System (INIS)

    Castoldi, M.C.; Fauda, V.; Scaramuzza, D.; Vergnaghi, D.

    2000-01-01

    Purpose of this work is to compare prospectively dynamic gadolinium (Gd)-enhanced with superparamagnetic iron oxide (SPIO)-enhanced MRI for the detection of hepatocellular carcinoma (HCC). Twenty-five patients with histologically proven HCC and liver cirrhosis (28% of them in B or C Child class) underwent dynamic Gd-enhanced MRI and, a few days later, (mean interval: three days) SPIO-enhanced MRI. Only patients with availability of clinical and imaging follow-up for at least seven months were enrolled in this prospective study. MR images were reviewed by two independent radiologists. The readers scored each lesion for the presence of HCC and assigned confidence levels based on a five-grade scale: 1, definitely or almost definitely absent; 2, possibly present; 3, probably present; 4, definitely present; 5, definitely present with optimal liver/lesion contrast or good liver/lesion contrast and morphological signs (intact capsule, intranodular septa, extracapsular infiltration), useful for locoregional treatment planning. A positive diagnostic value was assessed for scores of 3 or higher. Gd-enhanced and SPIO-enhanced MRI found 44 lesions. Eight of twelve lesions visible with a single contrast agent measured less than 1 cm in diameter. HCC detectability was 75% with Gd-enhanced MRI and 97.7% with SPIO-enhanced MRI. SPIO-enhanced T2-weighted TSE images showed significantly higher diagnostic value than SPIO-enhanced T1-T2*GRE images only in three cases, while nodule morphological characteristics (capsule, septa, different cell differentiation components) were better depicted by TSE images. In thi study the combined use of SPIO-enhanced T2-weighted TSE and T1-T2*-weighted GRE sequences showed higher sensitivity than gadolinium-enhanced GRE dynamic imaging (97.7% versus 75%). These results are at least partly related to our study conditions, that is: 1)MRI was performed with a 1T system, 2) both axial and sagittal SPIO-enhanced imaging were performed with respiratory

  14. Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform.

    Science.gov (United States)

    Xanthopoulos, Emily; Hutchinson, Charles E; Adams, Judith E; Bruce, Ian N; Nash, Anthony F P; Holmes, Andrew P; Taylor, Christopher J; Waterton, John C

    2007-01-01

    Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.

  15. The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Evrim Özmen

    2016-06-01

    Full Text Available Background: Contrast enhanced magnetic resonance cholangiography is a novel technique and promising method in demonstrating biliary tree anatomy and evaluating biliary disorders. However, to date, there are a limited number of studies that have focused on the impact of this technique. Aims: We aimed to evaluate the additional role of contrast enhanced MR cholangiography (MRC and compare contrast enhanced MRC with T2-weighted (w magnetic resonance cholangiopancreatography (MRCP in the diagnosis of biliary disorders. Study Design: Diagnostic accuracy study. Methods: The T2w-MRCP and contrast enhanced MRC sequences of 31 patients whose gold standard test results were available were scored visually for the existence of pathological findings with regard to any of the biliary diseases. Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA was used as the contrast agent. The correlation values were determined according to the statistical analysis made from those scores and the sensitivity, specificity and accuracy values of each sequence were detected as well. Results: We detected that the correlation values with gold standard methods of contrast enhanced MRC sequences were significantly higher than the ones of T2w-MRCP sequences. The correlation ratios of T2w-MRCP sequences were between 26 and 34%, while those for contrast enhanced MRC sequences were between 81 and 83% for the first reader and the correlation ratios of T2w-MRCP sequences were between 10 and 61%, whereas those of contrast enhanced MRC were between 79 and 81% for the second reader The mean sensitivity, specificity and accuracy values of T2w-MRCP sequences were 14.3-42.5%, 85-89.2% and 59.3-72.5%, respectively, while the mean sensitivity, specificity and accuracy values of contrast enhanced MRC sequences were 100%, 86.7% and 93.2-93.3%, respectively. Conclusion: We suggest that obtaining of contrast enhanced MRC sequences in addition to the T2w-MRCP can be useful in

  16. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver: The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient (ADC)

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Podgórska, Joanna; Rosiak, Grzegorz; Maj, Edyta; Grudziński, Ireneusz P.; Kaczyński, Bartosz; Szeszkowski, Wojciech; Milczarek, Krzysztof; Rowiński, Olgierd

    2016-01-01

    To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving

  17. High contrast enhancement aspect of dynamic computed tomography with arterial infusion - DCT-AI

    International Nuclear Information System (INIS)

    Kato, Seishi; Iwasaki, Naoya; Matsumura, Yoshimitsu; Kuramae, Shigeru; Mishiro, Tadashi

    1983-01-01

    Dynamic computed tomography was performed on 112 cases possibly having hepatic tumors with intraarterial infusion of undiluted contrast into a selectively placed catheter following angiographies. Our dynamic program could evaluate not only early phase of enhancement but also late phase up to 120 sec. Reconstructed views from early scans and magnified views were very useful to evaluate minute sequential changes. Hepatic masses less than 5 cm in size were found in thirty-one cases. Patterns of tumor enhancement and time-density curves have been analysed to correlate them with histology. Four types of tumor enhancement were noted: (1) homogeneous (2) patchy (3) mottled (4) ringed. Characteristic changes were observed in hepatocellular carcinoma - HCC - (mostly mottled) and haemangioma (mostly patchy). The former was divided in two groups reflecting the cellular maturity. The metastatic tumor could be enhanced in a ringed form with dendritic pattern of supplying vascularities in some cases. To support the use of undiluted contrast and to investigate the diagnostic efficacy of high contrast enhancement, experiments were performed by taking transaxial views of an acrylic phantom immersed in different concentrations of contrast. Analysis of CT images taken at different HU values ranging from 0 to 450 demonstrated that the higher the concentration of contrast, the better the spatial resolution was. Also larger magnification could be expected by using higher concentration of contrast. Although our Dynamic Computed Tomography with Arterial Infusion of Contrast still has drawbacks and limited indications, we advocate it as a better way of enhancement to detect and evaluate the hepatic masses, which sometimes elude the examiner's grasp with conventional way of enhancement. (author)

  18. Analysis of normal tongue by dynamic enhanced MRI

    International Nuclear Information System (INIS)

    Ariyoshi, Yasunori; Shimahara, Masashi

    2003-01-01

    We qualitatively evaluated dynamic enhanced MR images of normal tongues of 26 patients without oral malignancy, inflammatory diseases or systemic diseases. The selected slices were not affected by apparent artifacts including motion and susceptibility, and the tongue shape was delineated as symmetrical on coronal images, which were obtained using a T1 weighted spin echo pulse sequence (repetition time/echo time (TR/TE)=200/20). Slices at the incisor and molar levels were evaluated. Structures that could be identified on each pre-contrast image could also be identified on the post-contrast dynamic enhanced image. However, identification of the intrinsic tongue musculature was impossible on the images that were composed of symmetrical, relatively high signal areas surrounded by a low signal area. Both areas were gradually but apparently enhanced. The sublingual space was easily identified at the molar level, as it was rapidly enhanced and symmetrically delineated on each image, however, it was difficult to determine at the incisor level. Further, the lingual septum could also be identified in almost all images at the molar level, and showed no enhancement pattern, whereas, the mucosal surface of the dorsum tongue was rapidly enhanced, and identified on each image. (author)

  19. Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: Can image quality be maintained?

    Science.gov (United States)

    Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V

    2018-02-01

    In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  20. Dynamic MR imaging in Tolosa-Hunt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Tabassum Laz; Miki, Yukio; Kashii, Satoshi; Yamamoto, Akira; Kanagaki, Mitsunori; Takahashi, Takahiro; Fushimi, Yasutaka; Asato, Reinin; Murase, Nagako; Shibasaki, Hiroshi; Konishi, Junji

    2004-09-01

    Objective: To evaluate the cavernous sinuses with dynamic magnetic resonance (MR) imaging in patients with Tolosa-Hunt syndrome (THS). Methods: The sellar and parasellar regions of five patients with THS and 12 control subjects were examined with dynamic MR (1.5 T) imaging in the coronal plane. Dynamic images were obtained with spin-echo (SE) sequences in three patients, and with fast spin-echo (FSE) sequences in two patients and control subjects. Conventional MR images of the cranium including sellar and parasellar regions were also obtained on T1-weighted pre- and post-contrast SE, and T2-weighted FSE sequences in the coronal plane. Results: MR images revealed affected cavernous sinus with bulged convex lateral wall in three patients and concave lateral wall in two patients. In all control subjects, cavernous sinuses were observed with concave lateral wall. The signal intensity on T1- and T2-weighted images and contrast enhancement on post-contrast images of the affected cavernous sinuses in patients were similar to those of the unaffected cavernous sinuses in patients and control subjects. The dynamic images in all patients disclosed small areas adjacent to the cranial nerve filling-defects within the enhanced venous spaces of the affected cavernous sinus, which showed slow and gradual enhancement from the early to the late dynamic images. No such gradually enhancing area was observed in control subjects except one. The follow-up dynamic MR images after corticosteroid therapy revealed complete resolution of the gradually enhancing areas in the previously affected cavernous sinus. Conclusion: Dynamic MR imaging may facilitate the diagnosis of THS.

  1. Dynamic MR imaging in Tolosa-Hunt syndrome

    International Nuclear Information System (INIS)

    Haque, Tabassum Laz; Miki, Yukio; Kashii, Satoshi; Yamamoto, Akira; Kanagaki, Mitsunori; Takahashi, Takahiro; Fushimi, Yasutaka; Asato, Reinin; Murase, Nagako; Shibasaki, Hiroshi; Konishi, Junji

    2004-01-01

    Objective: To evaluate the cavernous sinuses with dynamic magnetic resonance (MR) imaging in patients with Tolosa-Hunt syndrome (THS). Methods: The sellar and parasellar regions of five patients with THS and 12 control subjects were examined with dynamic MR (1.5 T) imaging in the coronal plane. Dynamic images were obtained with spin-echo (SE) sequences in three patients, and with fast spin-echo (FSE) sequences in two patients and control subjects. Conventional MR images of the cranium including sellar and parasellar regions were also obtained on T1-weighted pre- and post-contrast SE, and T2-weighted FSE sequences in the coronal plane. Results: MR images revealed affected cavernous sinus with bulged convex lateral wall in three patients and concave lateral wall in two patients. In all control subjects, cavernous sinuses were observed with concave lateral wall. The signal intensity on T1- and T2-weighted images and contrast enhancement on post-contrast images of the affected cavernous sinuses in patients were similar to those of the unaffected cavernous sinuses in patients and control subjects. The dynamic images in all patients disclosed small areas adjacent to the cranial nerve filling-defects within the enhanced venous spaces of the affected cavernous sinus, which showed slow and gradual enhancement from the early to the late dynamic images. No such gradually enhancing area was observed in control subjects except one. The follow-up dynamic MR images after corticosteroid therapy revealed complete resolution of the gradually enhancing areas in the previously affected cavernous sinus. Conclusion: Dynamic MR imaging may facilitate the diagnosis of THS

  2. Measurement of perfusion using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI in neurooncology. Physical basics and clinical applications; Perfusionsmessung mit der T2*-Kontrastmitteldynamik in der Neuroonkologie. Physikalische Grundlagen und klinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.-A.; Giesel, F.L.; Kauczor, H.-U.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Radiologie; Risse, F.; Schad, L.R. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Medizinische Physik in der Radiologie

    2005-07-01

    Perfusion imaging in the central nervous system (CNS) is mostly performed using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI. The first-pass of a contrast bolus in brain tissue is monitored by a series of T2*-weighted MR images. The susceptibility effect of the paramagnetic contrast agent leads to a signal loss that can be converted, using the principles of the indicator dilution theory, into an increase of the contrast agent concentration. From these data, parameter maps of cerebral blood volume (CBV) and flow (CBF) can be derived. Regional CBF and CBV values can be obtained by region-of-interest analysis. This review article describes physical basics of DSC MRI and summarizes the literature of DSC MRI in neurooncological issues. Studies, all with relatively limited patient numbers, report that DSC MRI is useful in the preoperative diagnosis of gliomas, CNS-lymphomas, and solitary metastases, as well as in the differentiation of these neoplastic lesions from infections and tumor-like manifestations of demyelinating disease. Additionally, DSC MRI is suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy. After therapy, DSC MRI helps better assessing the tumor response to therapy, residual tumor after therapy, and possible treatment failure and therapy-related complications, such as radiation necrosis. The preliminary results show that DSC MRI is a diagnostic tool depicting regional variations in microvasculature of normal and diseased brains. (orig.) [German] Die MRT-Perfusionsmessungen im Zentralnervensystem (ZNS) werden derzeit hauptsaechlich mit der kontrastmittelverstaerkten T2*-Dynamik durchgefuehrt, die die Passage eines schnellen Kontrastmittelbolus mit einer Serie von T2*-gewichteten MRT-Aufnahmen verfolgt und charakterisiert. Dabei wird der Signalabfall, bedingt durch den Suszeptibilitaetseffekt des paramagnetischen Kontrastmittels, mittels geeigneter

  3. Added value of contrast-enhanced CISS imaging in relation to conventional MR images for the evaluation of intracavernous cranial nerve lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Akiko; Takahashi, Ayako; Morita, Hideo; Amanuma, Makoto; Endo, Keigo [Gunma University School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Gunma (Japan); Sato, Noriko [National Center Hospital of Neurology and Psychiatry, Department of Radiology, Kodaira, Tokyo (Japan); Takeuchi, K. [Takasaki University of Health and Welfare, Department of Health and Welfare, Gunma (Japan)

    2010-12-15

    The normal cranial nerves (CNs) of the cavernous sinus can be clearly demonstrated using contrast-enhanced constructive interference in steady-state (CISS) magnetic resonance imaging (MRI). This study used the method to evaluate pathological CNs III, IV, V{sub 1}, V{sub 2}, and VI in cavernous sinuses affected by inflammatory and neoplastic diseases. MR images from 17 patients with diseases involving the cavernous sinuses and/or causing neuropathy in CNs III-VI were retrospectively evaluated. The patients were divided into inflammatory (n = 11) and neoplastic (n = 6) groups. We defined CNs as abnormal when they exhibited enlargement or enhancement. CNs were evaluated using both contrast-enhanced CISS and T1-weighted MRI. In the inflammatory group, abnormal CNs were identified by contrast-enhanced CISS MRI in 13 of 25 symptomatic CNs (52%) in eight patients, but in only two CNs (8%) in two patients by contrast-enhanced T1-weighted MRI. In the neoplastic group, both sequences of contrast-enhanced CISS and T1-weighted MRI detected abnormalities in the same three of eight symptomatic CNs (37.5%), i.e., the three CNs were all in the same patient with adenoid cystic carcinoma. Contrast-enhanced CISS MRI is useful for detecting CN abnormalities in inflammatory pathological conditions of the cavernous sinuses. (orig.)

  4. Perfusion characteristics of late radiation injury of parotid glands: quantitative evaluation with dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Juan, Chun-Jung; Chen, Cheng-Yu.; Hsueh, Chun-Jen; Huang, Guo-Shu; Jen, Yee-Min; Liu, Hua-Shan; Wang, Chao-Ying; Chung, Hsiao-Wen; Liu, Yi-Jui; Chou, Yu-Ching; Chai, Yao-Te

    2009-01-01

    We aimed to quantitatively investigate the alteration of parotid perfusion after irradiation using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on a two-compartment tracer kinetic model. This study enrolled 19 patients (53.2±14.9 years) treated by head and neck radiotherapy and 19 age-relevant and sex-matched subjects as a control group. Perfusion parameters (K el , k 21 and A) of parotid glands were analyzed based on the Brix model from T1-weighted DCE-MRI. Suitability of the Brix model was evaluated via Monte Carlo simulation for the goodness-of-fit. Analysis of nonlinear goodness-of-fit showed that the Brix model is appropriate in evaluating the parotid perfusion (R 2 = 0.938±0.050). The irradiated parotid glands showed significantly lower K el (P 21 (P < 0.05) and consequently significantly higher value of peak enhancement (P<0.0005) and time-to-peak (P<0.0005) compared with non-irradiated ones, suggestive of gradual and prolonged accumulation and delayed wash-out of contrast agent due to increased extracellular extravascular space and decreased vascular permeability in the irradiated glands. Linear regression analysis showed dose-dependent perfusion changes of the irradiated parotid glands. We conclude that quantitative DCE-MRI is a potential tool in investigating parotid gland perfusion changes after radiotherapy. (orig.)

  5. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  6. Repeatability and correlations of dynamic contrast enhanced and T2* MRI in patients with advanced pancreatic ductal adenocarcinoma.

    Science.gov (United States)

    Klaassen, Remy; Gurney-Champion, Oliver J; Wilmink, Johanna W; Besselink, Marc G; Engelbrecht, Marc R W; Stoker, Jaap; Nederveen, Aart J; van Laarhoven, Hanneke W M

    2018-07-01

    In current oncological practice of pancreatic ductal adenocarcinoma (PDAC), there is a great demand for response predictors and markers for early treatment evaluation. In this study, we investigated the repeatability and the interaction of dynamic contrast enhanced (DCE) and T2* MRI in patients with advanced PDAC to enable for such evaluation using these techniques. 15 PDAC patients underwent two DCE, T2* and anatomical 3 T MRI sessions before start of treatment. Parametric maps were calculated for the transfer constant (K trans ), rate constant (k ep ), extracellular extravascular space (v e ) and perfusion fraction (v p ). Quantitative R2* (1/T2*) maps were obtained from the multi-echo T2* images. Differences between normal and cancerous pancreas were determined using a Wilcoxon matched pairs test. Repeatability was obtained using Bland-Altman analysis and relations between DCE and T2*/R2* were observed by Spearman correlation and voxel-wise binned plots of tumor voxels. PDAC K trans (p = 0.007), k ep (p T2*. Voxel wise analysis showed a steep increase in R2* for tumor voxels with lower K trans and v e . We showed good repeatability of DCE and T2* related MRI parameters in advanced PDAC patients. Furthermore, we have illustrated the relation of DCE K trans and v e with tissue T2* and R2* indicating substantial value of these parameters for detecting tumor hypoxia in future studies. The results from our study pave the way for further response evaluation studies and patient selection based on DCE and T2* parameters. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Multiple renal aspergillus abscesses in an AIDS patient: contrast-enhanced helical CT and MRI findings

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kauczor, H.U.; Thelen, M.; Heussel, G.; Jahn, B.

    1999-01-01

    Renal insufficiency or allergic reactions for X-ray contrast agents are frequent limitations in immunocompromised hosts such as neutropenic or AIDS patients. Due to a better tolerance of contrast agents in MRI, this technique is well suited for investigation of parenchymal organs. We demonstrate an allergic AIDS patient who presented with fever and flank pain. At sonography, anechoic renal lesions were supposed to be non-complicated cysts; however, on T2-weighted MRI, the center was of high signal. Dynamic contrast-enhanced MRI of the kidneys demonstrated an enhancing rim with ill-defined margins. The lesions were supposed to be multiple bilateral abscesses. Due to the multiple dynamic contrast series, a delayed enhancement of renal parenchyma was detectable adjacent to the lesion. This was suggested as accompanying local pyelonephritis and an infectious etiology became more reliable. Aspergillus fumigatus was identified by CT-guided biopsy as the underlying microorganism. The MR appearance of this manifestation has not been described previously. (orig.)

  8. Prognosis prediction of non-enhancing T2 high signal intensity lesions in glioblastoma patients after standard treatment: application of dynamic contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Rihyeon; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho [Seoul National University Hospital, Department of Radiology, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Choi, Seung Hong [Seoul National University Hospital, Department of Radiology, 101 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, 103 Daehak-ro, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Center for Nanoparticle Research, Institute for Basic Science (IBS), Daehak-dong, Gwanak-gu, Seoul (Korea, Republic of); Seoul National University, School of Chemical and Biological Engineering, Daehak-dong, Gwanak-gu, Seoul (Korea, Republic of); Lee, Soon-Tae [Seoul National University Hospital, Department of Neurology, Seoul (Korea, Republic of); Park, Chul-Kee [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Kim, Tae Min [Seoul National University Hospital, Department of Internal Medicine, Seoul (Korea, Republic of); Park, Sun-Won [Seoul National University College of Medicine, Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Park, Sung-Hye [Seoul National University Hospital, Department of Pathology, Seoul (Korea, Republic of); Kim, Il Han [Seoul National University Hospital, Department of Radiation Oncology, Seoul (Korea, Republic of)

    2017-03-15

    To identify candidate imaging biomarkers for early disease progression in glioblastoma multiforme (GBM) patients by analysis of dynamic contrast-enhanced (DCE) MR parameters of non-enhancing T2 high signal intensity (SI) lesions. Forty-nine GBM patients who had undergone preoperative DCE MR imaging and received standard treatment were retrospectively included. According to the Response Assessment in Neuro-Oncology criteria, patients were classified into progression (n = 21) or non-progression (n = 28) groups. We analysed the pharmacokinetic parameters of Ktrans, Ve and Vp within non-enhancing T2 high SI lesions of each tumour. The best percentiles of each parameter from cumulative histograms were identified by the area under the receiver operating characteristic curve (AUC) and were compared using multivariate stepwise logistic regression. For the differentiation of early disease progression, the highest AUC values were found in the 99th percentile of Ktrans (AUC 0.954), the 97th percentile of Ve (AUC 0.815) and the 94th percentile of Vp (AUC 0.786) (all p < 0.05). The 99th percentile of Ktrans was the only significant independent variable from the multivariate stepwise logistic regression (p = 0.002). We found that the Ktrans of non-enhancing T2 high SI lesions in GBM patients holds potential as a candidate prognostic marker in future prospective studies. (orig.)

  9. Prostate cancer detection from model-free T1-weighted time series and diffusion imaging

    Science.gov (United States)

    Haq, Nandinee F.; Kozlowski, Piotr; Jones, Edward C.; Chang, Silvia D.; Goldenberg, S. Larry; Moradi, Mehdi

    2015-03-01

    The combination of Dynamic Contrast Enhanced (DCE) images with diffusion MRI has shown great potential in prostate cancer detection. The parameterization of DCE images to generate cancer markers is traditionally performed based on pharmacokinetic modeling. However, pharmacokinetic models make simplistic assumptions about the tissue perfusion process, require the knowledge of contrast agent concentration in a major artery, and the modeling process is sensitive to noise and fitting instabilities. We address this issue by extracting features directly from the DCE T1-weighted time course without modeling. In this work, we employed a set of data-driven features generated by mapping the DCE T1 time course to its principal component space, along with diffusion MRI features to detect prostate cancer. The optimal set of DCE features is extracted with sparse regularized regression through a Least Absolute Shrinkage and Selection Operator (LASSO) model. We show that when our proposed features are used within the multiparametric MRI protocol to replace the pharmacokinetic parameters, the area under ROC curve is 0.91 for peripheral zone classification and 0.87 for whole gland classification. We were able to correctly classify 32 out of 35 peripheral tumor areas identified in the data when the proposed features were used with support vector machine classification. The proposed feature set was used to generate cancer likelihood maps for the prostate gland.

  10. Combined diffusion-weighted, blood oxygen level-dependent, and dynamic contrast-enhanced MRI for characterization and differentiation of renal cell carcinoma.

    Science.gov (United States)

    Notohamiprodjo, Mike; Staehler, Michael; Steiner, Nicole; Schwab, Felix; Sourbron, Steven P; Michaely, Henrik J; Helck, Andreas D; Reiser, Maximilian F; Nikolaou, Konstantin

    2013-06-01

    To investigate a multiparametric magnetic resonance imaging (MRI) approach comprising diffusion-weighted imaging (DWI), blood oxygen-dependent (BOLD), and dynamic contrast-enhanced (DCE) MRI for characterization and differentiation of primary renal cell carcinoma (RCC). Fourteen patients with clear-cell carcinoma and four patients with papillary RCC were examined with DWI, BOLD MRI, and DCE MRI at 1.5T. The apparent diffusion coefficient (ADC) was calculated with a monoexponential decay. The spin-dephasing rate R2* was derived from parametric R2* maps. DCE-MRI was analyzed using a two-compartment exchange model allowing separation of perfusion (plasma flow [FP] and plasma volume [VP]), permeability (permeability surface area product [PS]), and extravascular extracellular volume (VE). Statistical analysis was performed with Wilcoxon signed-rank test, Pearson's correlation coefficient, and receiver operating characteristic curve analysis. Clear-cell RCC showed higher ADC and lower R2* compared to papillary subtypes, but differences were not significant. FP of clear-cell subtypes was significantly higher than in papillary RCC. Perfusion parameters showed moderate but significant inverse correlation with R2*. VE showed moderate inverse correlation with ADC. Fp and Vp showed best sensitivity for histological differentiation. Multiparametric MRI comprising DWI, BOLD, and DCE MRI is feasible for assessment of primary RCC. BOLD moderately correlates to DCE MRI-derived perfusion. ADC shows moderate correlation to the extracellular volume, but does not correlate to tumor oxygenation or perfusion. In this preliminary study DCE-MRI appeared superior to BOLD and DWI for histological differentiation. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  11. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    International Nuclear Information System (INIS)

    Park, Sung Bin; Moon, Min Hoan; Sung, Chang Kyu; Oh, Sohee; Lee, Young Ho

    2014-01-01

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  12. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  13. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Takumi, Koji; Higashi, Michiyo; Shinchi, Hiroyuki; Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro

    2014-01-01

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival

  14. Assessment of T2-Weighted Coronal Magnetic Resonance Images in the Investigation of Pituitary Lesions

    International Nuclear Information System (INIS)

    Yuksekkaya, Ruken; Aggunlu, Levent; Oner, Yusuf; Celik, Halil; Akpek, Sergin; Celikyay, Fatih

    2014-01-01

    Magnetic resonance imaging is the most important diagnostic method in the investigation of the pituitary lesions. Our aim is to determine whether T2-weighted coronal images may be helpful in the evaluation of the pituitary gland with suspected pituitary adenomas. One hundred and sixty-seven patients were examined prospectively with T2-weighted coronal and T1-weighted coronal images enhanced with intravenous contrast material. The images were evaluated for the presence, the size, the location, and the ancillary signs including sellar floor erosion or ballooning, infindibulary deviation, convexity of the superior border of the gland, diffuse enlargement of the gland, and the invasion of the cavenous sinuses on both images. In forty-six (28%) patients lesions were revealed on both sequences. In twenty-one (12%) patients the lesions that were revealed on the T1-weighted images were not detected on the T2-weighted images. Positive predictive value, negative predictive value, sensitivity, specificity, and diagnostic accuracy rates of T2-weighted coronal images on the detection of the presence of lesions were 100%, 17.4%, 68.7%, 100%, and 87.4%, respectively. Both T2-weighted coronal and T1-weighted coronal images enhanced with intravenous gadolinium-based contrast material are important in the diagnosis of pituitary adenomas. T2-weighted coronal images could be used as a screening tool for the primary evaluation of the pituitary gland

  15. Contrast-enhanced 3T MR perfusion of musculoskeletal tumours. T1 value heterogeneity assessment and evaluation of the influence of T1 estimation methods on quantitative parameters

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Verbizier, Jacques de; Blum, Alain [Hopital Central, CHRU-Nancy, Service d' Imagerie Guilloz, Nancy (France); Chen, Bailiang; Beaumont, Marine [Universite de Lorraine, Laboratoire IADI, UMR S 947, Nancy (France); Badr, Sammy; Cotten, Anne [CHRU Lille Centre de Consultations et d' Imagerie de l' Appareil Locomoteur, Department of Radiology and Musculoskeletal Imaging, Lille (France)

    2017-12-15

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. (orig.)

  16. 3D Fast Spin Echo T2-weighted Contrast for Imaging the Female Cervix

    Science.gov (United States)

    Vargas Sanchez, Andrea Fernanda

    Magnetic Resonance Imaging (MRI) with T2-weighted contrast is the preferred modality for treatment planning and monitoring of cervical cancer. Current clinical protocols image the volume of interest multiple times with two dimensional (2D) T2-weighted MRI techniques. It is of interest to replace these multiple 2D acquisitions with a single three dimensional (3D) MRI acquisition to save time. However, at present the image contrast of standard 3D MRI does not distinguish cervical healthy tissue from cancerous tissue. The purpose of this thesis is to better understand the underlying factors that govern the contrast of 3D MRI and exploit this understanding via sequence modifications to improve the contrast. Numerical simulations are developed to predict observed contrast alterations and to propose an improvement. Improvements of image contrast are shown in simulation and with healthy volunteers. Reported results are only preliminary but a promising start to establish definitively 3D MRI for cervical cancer applications.

  17. Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle

    Directory of Open Access Journals (Sweden)

    Sbarbati Andrea

    2002-06-01

    Full Text Available Abstract Background Studies about capillarity of the aged muscle provided conflicting results and no data are currently available about the magnetic resonance imaging (MRI in vivo characteristics of the microvascular bed in aged rats. We have studied age-related modifications of the skeletal muscle by in vivo T2-relaxometry and dynamic contrast-enhanced magnetic resonance imaging (CE-MRI at high field intensity (4.7 T. The aim of the work was to test the hypothesis that the ageing process involves microvessels in skeletal muscle. Methods The study was performed in 4-month-old (n = 6 and 20-month-old (n = 6 rats. Results At MRI examination, the relaxation time T2 of the gastrocnemius muscle showed no significant difference between these two groups. The kinetic of contrast penetration in the tissue showed that in 4-month-old rats the enhancement values of the signal intensity at different time-points were significantly higher than those found in senescent rats. Conclusion The reported finding suggests that there is a modification of the microcirculatory function in skeletal muscle of aged rats. This work also demonstrates that CE-MRI allows for an in vivo quantification of the multiple biological processes involving the skeletal muscle during aging. Therefore, CE-MRI could represent a further tool for the follow up of tissue modification and therapeutic intervention both in patients with sarcopenia and in experimental models of this pathology.

  18. Reconstructed anterior cruciate ligaments using patellar tendon ligament grafts: diagnostic value of contrast-enhanced MRI in a 2-year follow-up regimen

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Schmitt, J.; Lubrich, J.; Hochmuth, K.; Diebold, T. [Dept. of Diagnostic and Interventional Radiology, Frankfurt Univ. (Germany); Del Tredici, K. [Dept. of Clinical Neuroanatomy, Frankfurt Univ. (Germany); Suedkamp, N. [Dept. of Traumatology and Orthopedics, Humboldt University, Berlin (Germany)

    2001-08-01

    We analyzed prospectively the diagnostic efficacy of contrast-enhanced MRI following anterior cruciate neoligament (ACL) reconstruction. One hundred fifty-six MR examinations were performed 2, 12, 52, 76, and 104 weeks post-operatively on 68 patients with ACL transplants. Sagittal, parasagittal, and coronal images using unenhanced T1- and T2-weighted spin-echo sequences, and post-contrast images utilizing T1-weighted spin-echo and fat-saturated sequences, were acquired. Results were correlated with those of the pivot shift, Lachman, and a mechanical test. The MR examination criteria included morphological analysis, signal intensity, transplant contrast enhancement, secondary signs (e.g., elongation of normal ligaments), and comparison with clinically standardized test results. Two weeks post-operatively all neoligaments showed homogeneous low signal intensity on T1- and T2-weighted spin-echo sequences indistinguishable from that of normal cruciate or patellar ligaments [contrast-to-noise ratio (C/N) on T1:1.6], with a 9% percentile enhancement. At 12-52 weeks, signal intensity increased (C/N:6.7), with a mean 50% percentile enhancement. The 1-year follow-up allowed no definite assessment of the neoligament's course. At 76 and 104 weeks, significant decrements in signal intensity (C/N:3.0) and ligamentous percentile enhancement (25%) occurred. All patients tested displayed stable transplants 2 years post-operatively. Contrast-enhanced MRI allows accurate evaluation of morphology and function up to 3 months post-operatively and 1-2 years following ACL reconstructive surgery. (orig.)

  19. Ultrashort Echo Time Magnetic Resonance Imaging of the Lung Using a High-Relaxivity T1 Blood-Pool Contrast Agent

    Directory of Open Access Journals (Sweden)

    Joris Tchouala Nofiele

    2014-10-01

    Full Text Available The lung remains one of the most challenging organs to image using magnetic resonance imaging (MRI due to intrinsic rapid signal decay. However, unlike conventional modalities such as computed tomography, MRI does not involve radiation and can provide functional and morphologic information on a regional basis. Here we demonstrate proof of concept for a new MRI approach to achieve substantial gains in a signal to noise ratio (SNR in the lung parenchyma: contrast-enhanced ultrashort echo time (UTE imaging following intravenous injection of a high-relaxivity blood-pool manganese porphyrin T1 contrast agent. The new contrast agent increased relative enhancement of the lung parenchyma by over 10-fold compared to gadolinium diethylene triamine pentaacetic acid (Gd-DTPA, and the use of UTE boosted the SNR by a factor of 4 over conventional T1-weighted gradient echo acquisitions. The new agent also maintains steady enhancement over at least 60 minutes, thus providing a long time window for obtaining high-resolution, high-quality images and the ability to measure a number of physiologic parameters.

  20. Malignancy assessment of brain tumours with magnetic resonance spectroscopy and dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Fayed, Nicolas; Davila, Jorge; Medrano, Jaime [Diagnostic Radiology Department, Clinica Quiron, Zaragoza (Spain); Olmos, Salvador [Instituto de Investigacion en Ingenieria de Aragon, Zaragoza (Spain)], E-mail: olmos@unizar.es

    2008-09-15

    Magnetic resonance imaging (MRI) is the most common and well-established imaging modality for evaluation of intracerebral neoplasms, but there are still some incompletely solved challenges, such as reliable distinction between high- and low-grade tumours, exact delineation of tumour extension, and discrimination between recurrent tumour and radiation necrosis. The aim of this study was to evaluate the contribution of two MRI techniques to non-invasively estimate brain tumour grade. Twenty-four patients referred to MRI examination were analyzed and diagnosed with single intra-axial brain tumour. Lastly, histopathological analysis was performed to verify tumour type. Ten patients presented low-grade gliomas, while the remaining patients showed high-grade tumours, including glioblastomas in eight cases, isolated metastases in four patients and two cases with anaplastic gliomas. MRI examinations were performed on a 1.5-T scanner (Signa, General Electric). The acquisition protocol included the following sequences: saggital T1-weighted localizer, axial T1- and T2-weighted MRI, single-voxel magnetic resonance spectroscopy (MRS), dynamic susceptibility contrast (DSC) MRI and contrast-enhanced T1-weighted MRI. MRS data was analyzed with standard software provided by the scanner manufacturer. The metabolite ratio with the largest significant difference between tumour grades was the choline/creatine (Ch/Cr) ratio with elevated values in high-grade gliomas and metastases. A Ch/Cr ratio equal or larger than 1.55 predicted malignancy grade with 92% sensitivity and 80% specificity. The area under the ROC curve was 0.92 (CI: 95%; 0.81-1). Regarding to perfusion parameters, relative cerebral blood volume (rCBV) maps were estimated from the MR signal intensity time series during bolus passage with two commercial software packages. Two different regions of interest (ROI) were used to evaluate rCBV: lesion centre and perilesional region. All rCBV values were normalized to CBV in a

  1. Malignancy assessment of brain tumours with magnetic resonance spectroscopy and dynamic susceptibility contrast MRI

    International Nuclear Information System (INIS)

    Fayed, Nicolas; Davila, Jorge; Medrano, Jaime; Olmos, Salvador

    2008-01-01

    Magnetic resonance imaging (MRI) is the most common and well-established imaging modality for evaluation of intracerebral neoplasms, but there are still some incompletely solved challenges, such as reliable distinction between high- and low-grade tumours, exact delineation of tumour extension, and discrimination between recurrent tumour and radiation necrosis. The aim of this study was to evaluate the contribution of two MRI techniques to non-invasively estimate brain tumour grade. Twenty-four patients referred to MRI examination were analyzed and diagnosed with single intra-axial brain tumour. Lastly, histopathological analysis was performed to verify tumour type. Ten patients presented low-grade gliomas, while the remaining patients showed high-grade tumours, including glioblastomas in eight cases, isolated metastases in four patients and two cases with anaplastic gliomas. MRI examinations were performed on a 1.5-T scanner (Signa, General Electric). The acquisition protocol included the following sequences: saggital T1-weighted localizer, axial T1- and T2-weighted MRI, single-voxel magnetic resonance spectroscopy (MRS), dynamic susceptibility contrast (DSC) MRI and contrast-enhanced T1-weighted MRI. MRS data was analyzed with standard software provided by the scanner manufacturer. The metabolite ratio with the largest significant difference between tumour grades was the choline/creatine (Ch/Cr) ratio with elevated values in high-grade gliomas and metastases. A Ch/Cr ratio equal or larger than 1.55 predicted malignancy grade with 92% sensitivity and 80% specificity. The area under the ROC curve was 0.92 (CI: 95%; 0.81-1). Regarding to perfusion parameters, relative cerebral blood volume (rCBV) maps were estimated from the MR signal intensity time series during bolus passage with two commercial software packages. Two different regions of interest (ROI) were used to evaluate rCBV: lesion centre and perilesional region. All rCBV values were normalized to CBV in a

  2. Assessment of brain metastases by means of dynamic susceptibility contrast enhanced MRI

    International Nuclear Information System (INIS)

    Knopp, M.; Wenz, F.; Debus, J.; Hentrich, H.R.

    2002-01-01

    Full text: To assess if pre therapeutic measurements of regional cerebral blood flow (rCBF) and volume (rCVB) are able to predict the response of brain metastases to radiation therapy and to assess the influence of radiosurgery on rCBF and rCBV on brain metastases and normal surrounding tissue. We examined 25 patients with brain metastases prior to high dose radiosurgery with conventional T1 and T2 weighted MRI and dynamic susceptibility contrast enhanced MRI (DSC MRI). For DSC MRI 55 T2*w GE images of two sections were acquired after bolus administration of 0.1 mmol/kg gadoteridol (ProHance) for the simultaneous measurement of brain feeding arteries and brain tissue. This allowed an absolute quantification of rCBF and rCBV. Follow-up examinations were performed 6 weeks and 3 months after radiotherapy and the acquired perfusion data were related to a 3 point scale of treatment outcome. Radiosurgery was performed by a linear accelerator with a 80% isodose of 18-20 Gv. For treatment planning the heads of the patients were immobilized by a cask mask to avoid head movement. DSC MRI was able to assess perfusion data in all patients. Higher pre therapeutic rCBV seems to predict a poor treatment outcome. After radiosurgery patients with tumor remission and stable disease presented a decrease of rCBV over time regardless of temporary tumor volume increase. Patients with tumor progression at the 3 month followup presented an increase of rCBV. Effects on normal surrounding tissue could not be observed. DSC MRI using Gadoteridol allows the non-invasive assessment of rCBV and rCBF of brain metastases and its changes due to radiosurgery. The method may also be able to predict treatment outcome. Furthermore radiofrequency effects on surrounding unaffected tissue can be monitored. Copyright (2002) Blackwell Science Pty Ltd

  3. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    International Nuclear Information System (INIS)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J.; Kreienberg, R.

    1999-01-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.)

  4. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  5. Prostate cancer: diagnostic value of dynamic contrast-enhanced MRI, diffusion weighted imaging and 3D 1H-MR spectroscopy

    International Nuclear Information System (INIS)

    Shi Hao; Wu Lebin; Ding Hongyu; Zhao Bin; Wang Tao; Yang Zhenzhen; Qiu Xiuling; Li Huihua; Qu Lei; Wu Yulong

    2006-01-01

    Objective: To explore the applying value of the diagnosis of dynamic contrast-enhanced MRI (DCE-MRI), diffusion weighted imaging (DWI) and 3D 1 H-MR spectroscopy (MRS) in prostate cancer (PC). Methods: Thirty-two cases with PC and 64 cases with benign prostatic hyperplasia (BPH) which were confirmed with biopsy-proven, operation and follow-up, and 29 healthy volunteers underwent the examinations of DCE-MRI, DWI and MRS. The signal intensity, ADC value, and Cho/Cit ratio and (Cho + Cr)/Cit ratio were measured respectively on the lesions of PC and BPH, normal prostatic peripheral zone (PZ) and normal prostatic central gland (CG) of DCE-MRI, DWI and MRS. The results were statistically treated with ANOVA. Results: The lesions showed obvious enhancement in the early phase of DCE-MRI and washed out in late phase in 18 of 22 cases with PC, who underwent the examination of DCE-MRI. The enhancement was obvious in early and strengthened gradually, and then went to decrease in late phase after peak value on the lesions in 38 of 40 cases with BPH. The signal intensities from different time and different lesions and tissues were treated statistically and the results showed that there were significant differences (P 0.05). The lesions were shown lower signal intensity on ADC map in 26 cases with PC, who were examined with DWI and the average ADC value was (104.23±26.15) x 10 -5 mm 2 /s. The average ADC Value of the lesions of 43 cases with BPH was (175.21±64.86) x 10 -5 mm 2 /s. The statistical analysis showed that there were significant differences between PC, BPH and CG except between PZ and BPH. Average Cho/Cit ratio and average (Cho + Cr)/Cit ratio of the lesions of PC were 2.26±0.91 and 2.85±1.01 respectively in 17 cases with PC, who were performed with MRS. The average Cho/Cit ratio and average (Cho + Cr)/Cit ratio were 0.46±0.23 and 0.57±0.20 respectively in 35 cases with BPH. After the statistical analyzing, the results presented that there were significant

  6. Diagnostic usefulness of endorectal magnetic resonance imaging with dynamic contrast-enhancement in patients with localized prostate cancer. Mapping studies with biopsy specimens

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Samma, Shoji; Joko, Masanori; Akiyama, Tatsuya; Takewa, Megumi; Kitano, Satoru; Okajima, Eigoro

    1999-01-01

    New diagnostic criteria for dynamic magnetic resonance (MR) imaging in prostate cancer are presented. The diagnostic usefulness of endorectal MR imaging with dynamic contrast-enhancement in localized prostate cancer and the validity of these criteria were evaluated. Eighteen untreated patients who were suspected of localized prostate cancer were included in the study. They received endorectal dynamic MR imaging before systematic sextant needle biopsy. First, a mapping study with the findings of MR images and histopathology of biopsy specimens was performed in eight patients out of 18 to compare the difference in T2-weighted images with the endorectal coil and the body coil in the same individuals. Second, another mapping study was performed in all 18 patients by analyzing the findings of endorectal dynamic MR images. For the diagnosis of prostate cancer in MR imaging, we offered diagnostic criteria from our experience in addition to those in plain T2-weighted images from the literature. The overall diagnostic rates of endorectal dynamic MR imaging were 88.9% in accuracy, 100% in sensitivity, and 81.8% in specificity. In the comparison of the endorectal and body coils in T2-weighted images in eight patients, there was no difference in the diagnostic rates except for one more histopathologic false positive portion in endorectal MR imaging. In the second mapping study in 18 patients, the diagnostic rates were 92.6% in accuracy, 88.9% in sensitivity and 93.3% in specificity. Endorectal dynamic imaging raised the diagnostic sensitivity from 77.8 to 88.9%. The data demonstrated the validity of this diagnostic criteria and the diagnostic usefulness of endorectal dynamic MR imaging in localized prostate cancer. (author)

  7. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Lavini, Cristina; Hemke, Robert; Caan, Matthan W.A.; Maas, Mario [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Dolman, Koert M. [Sint Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands); Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Rossum, Marion A.J. van [Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Emma Children' s Hospital, Department of Pediatrics, Academic Medical Center, Amsterdam (Netherlands)

    2017-02-15

    Dynamic contrast-enhanced MRI provides information on the heterogeneity of the synovium, the primary target of disease in children with juvenile idiopathic arthritis (JIA). To evaluate the feasibility of dynamic contrast-enhanced MRI in the wrist of children with JIA using conventional descriptive measures and time-intensity-curve shape analysis. To explore the association between enhancement characteristics and clinical disease status. Thirty-two children with JIA and wrist involvement underwent dynamic contrast-enhanced MRI with movement-registration and were classified using validated criteria as clinically active (n = 27) or inactive (n = 5). Outcome measures included descriptive parameters and the classification into time-intensity-curve shapes, which represent the patterns of signal intensity change over time. Differences in dynamic contrast-enhanced MRI outcome measures between clinically active and clinically inactive disease were analyzed and correlation with the Juvenile Arthritis Disease Activity Score was determined. Comprehensive evaluation of disease status was technically feasible and the quality of the dynamic dataset was improved by movement registration. The conventional descriptive measure maximum enhancement differed significantly between clinically active and inactive disease (P = 0.019), whereas time-intensity-curve shape analysis showed no differences. Juvenile Arthritis Disease Activity Score correlated moderately with enhancing volume (P = 0.484). Dynamic contrast-enhanced MRI is a promising biomarker for evaluating disease status in children with JIA and wrist involvement. Conventional descriptive dynamic contrast-enhanced MRI measures are better associated with clinically active disease than time-intensity-curve shape analysis. (orig.)

  8. Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K.; Baltzer, P.; Bernathova, M.; Weber, M.; Leithner, D.; Helbich, T.H. [Medical University Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, 1090, Vienna (Austria); Bogner, W.; Trattnig, S.; Gruber, S.; Zaric, O. [Medical University Vienna, Department of Biomedical Imaging and Image-guided Therapy, MR Centre of Excellence, Vienna (Austria); Abeyakoon, O. [King' s College, Department of Radiology, London (United Kingdom); Dubsky, P. [Medical University Vienna, Department of Surgery, Vienna (Austria); Bago-Horvath, Z. [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2014-04-15

    The objective of our study was to evaluate the clinical application of bilateral high spatial and temporal resolution dynamic contrast-enhanced magnetic resonance imaging (HR DCE-MRI) of the breast at 7 T. Following institutional review board approval 23 patients with a breast lesion (BIRADS 0, 4-5) were included in our prospective study. All patients underwent bilateral HR DCE-MRI of the breast at 7 T (spatial resolution of 0.7 mm{sup 3} voxel size, temporal resolution of 14 s). Two experienced readers (r1, r2) and one less experienced reader (r3) independently assessed lesions according to BI-RADS registered. Image quality, lesion conspicuity and artefacts were graded from 1 to 5. Sensitivity, specificity and diagnostic accuracy were assessed using histopathology as the standard of reference. HR DCE-MRI at 7 T revealed 29 lesions in 23 patients (sensitivity 100 % (19/19); specificity of 90 % (9/10)) resulting in a diagnostic accuracy of 96.6 % (28/29) with an AUC of 0.95. Overall image quality was excellent in the majority of cases (27/29) and examinations were not hampered by artefacts. There was excellent inter-reader agreement for diagnosis and image quality parameters (κ = 0.89-1). Bilateral HR DCE-MRI of the breast at 7 T is feasible with excellent image quality in clinical practice and allows accurate breast cancer diagnosis. (orig.)

  9. Significance of Additional Non-Mass Enhancement in Patients with Breast Cancer on Preoperative 3T Dynamic Contrast Enhanced MRI of the Breast

    International Nuclear Information System (INIS)

    Cho, Yun Hee; Cho, Kyu Ran; Park, Eun Kyung; Seo, Bo Kyoung; Woo, Ok Hee; Cho, Sung Bum; Bae, Jeoung Won

    2016-01-01

    In preoperative assessment of breast cancer, MRI has been shown to identify more additional breast lesions than are detectable using conventional imaging techniques. The characterization of additional lesions is more important than detection for optimal surgical treatment. Additional breast lesions can be included in focus, mass, and non-mass enhancement (NME) on MRI. According to the fifth edition of the breast imaging reporting and data system (BI-RADS®), which includes several changes in the NME descriptors, few studies to date have evaluated NME in preoperative assessment of breast cancer. We investigated the diagnostic accuracy of BI-RADS descriptors in predicting malignancy for additional NME lesions detected on preoperative 3T dynamic contrast enhanced MRI (DCE-MRI) in patients with newly diagnosed breast cancer. Between January 2008 and December 2012, 88 patients were enrolled in our study, all with NME lesions other than the index cancer on preoperative 3T DCE-MRI and all with accompanying histopathologic examination. The MRI findings were analyzed according to the BI-RADS MRI lexicon. We evaluated the size, distribution, internal enhancement pattern, and location of NME lesions relative to the index cancer (i.e., same quadrant, different quadrant, or contralateral breast). On histopathologic analysis of the 88 NME lesions, 73 (83%) were malignant and 15 (17%) were benign. Lesion size did not differ significantly between malignant and benign lesions (P = 0.410). Malignancy was more frequent in linear (P = 0.005) and segmental (P = 0.011) distributions, and benignancy was more frequent in focal (P = 0.004) and regional (P < 0.001) NME lesions. The highest positive predictive value (PPV) for malignancy occurred in segmental (96.8%), linear (95.1%), clustered ring (100%), and clumped (92.0%) enhancement. Asymmetry demonstrated a high positive predictive value of 85.9%. The frequency of malignancy was higher for NME lesions located in the same quadrant with

  10. Renal enhancement and excretion of the hepatobiliary contrast agent Gd-EOB-DTPA

    International Nuclear Information System (INIS)

    Zangos, S.; Hammerstingl, R.; Mack, M.G.; Straub, R.; Engelmann, K.; Eichler, K.; Vogl, T.J.

    2001-01-01

    Purpose: To evaluate the clinical value of the renal clearance using MR imaging with different doses of gadolinium ethoxybenzyl-DTPA (Gd-EOB-DTPA) in comparison to gadolinium DTPA (Gd-DTPA). Material and Methods: In a double-blind and randomized clinical phase II study. MR imaging at 1.5 T was performed in 61 patients with five different doses of Gd-EOB-DTPA (3, 6, 12.5, 25 and 50 μmol/kg b.w. as a bolus injection). The study protocol comprised T 1 - and T 2 -weighted spin-echo magnetic resonance and two-dimensional fast low-angle shot imaging before and at increasing intervals for up to 45 min after injection of Gd-EOB-DTPA. These images were compared with Gd-DTPA-enhanced imaging (0.1 mmol/kg b. w. as a bolus injection). Results: After bolus injection of the hepatobiliary MR contrast agent Gd-EOB-DTPA a renal elimination was observed. Immediately after the injection of Gd-EOB-DTPA until the eighth minute a corticomedullary enhancement of the kidney was conspicuous. After the fourth minute a contrast enhancement could be seen in the renal pelvis. The best enhancement was noted after 20 minutes in the FLASH GRE and T 1 -weighted images with good pelvicaliceal contrast. After 45 minutes an outflow of Gd-EOB-DTPA into the ureter could be observed. Conclusion: In addition to the hepatobiliary secretion Gd-EOB-DTPA appears useful for the evaluation of renal structures and renal function on account of the renal excretion without diuretic preparation of the patients. (orig.) [de

  11. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Sun [Dept. of Radiology, Konkuk University School of Medicine, Seoul (Korea, Republic of); Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Young Il [Dept. of Radiology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah (United Arab Emirates); Choi, Jin Young [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.

  12. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    International Nuclear Information System (INIS)

    Park, Hee Sun; Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn; Kim, Young Il; Choi, Jin Young

    2015-01-01

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent

  13. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  14. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  15. Diagnostic value of contrast-enhanced dynamic CT in predicting the malignancy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Song, Koun Sik; Lee, Eun Hye; Kim, Ji Hoon; Lee, Jin Seong; Lim, Tae Hwan

    1997-01-01

    To determine whether the maximal enhancement time in dynamic CT is different between benign and malignant solitary pulmonary nodules (SPN)s, and to evaluate the value of densitometry on dynamic CT in predicting the malignancy of SPN. Fifty-six patients with SPN of less than 4cm in diameter as seen on chest radiograph and SPN without benign pattern of calcification or fat, as seen on pre-enhance-ment spiral CT scans were included in this study. SPN with small cavitation sufficient to measure CT density, were also included. Thirty-four SPNs were diagnosed pathologically or radiologically as 20 malignant nodules and 14 benign nodules. Dynamic CT was performed by two techniques after injection of 50ml of nonionic contrast media at the rate of 2ml/sec. In 28 patients, incremental dynamic CT was performed before and of 15 seconds, 1 minute, 2 minutes, 3 minutes, and 4 minutes after injection of contrast media during shallow respiration. In 28 patients, double spiral CT was performed 2 minutes and 3 minutes after injection of contrast media during single breath hold. CT readings were taken at the central portion of SPNs, with a circular region of interest. The degree and time of maximal enhancement were recorded. In dynamic CT the maximal enhancement time of SPNs was not significantly different between malignant (2.73±1.27 minute) and benign nodules (2.56±1.24 minute). The enhancement of malignant nodules was significantly greater (21.42±12.17 HU) than of benign nodules (5.15±5.25 HU) (p<.0001). In dynamic CT of SPNs, there is no difference in maximal enhancement time between benign and malignant nodules;enhancement of the latter is significantly greater than that of the former. Maximal enhancement greater than 15 HU can be a good predictor of malignancy of SPNs

  16. High signal in the spinal cord on T2-weighted images in rapidly progressive tropical spastic paraparesis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Hara, A.; Murakami, T.; Ando, Y.; Uyama, E.; Mita, S.; Uchino, M. [Kumamoto Univ. (Japan). School of Medicine; Yamashita, T. [Kumamoto Univ. (Japan). School of Medicine; Dept. of Neurology, Kumamoto Univ. (Japan)

    2001-03-01

    We report a 59-year-old woman with human T-cell lymphotrophic virus type-I (HTLV-I) associated myelopathy/tropical spastic paraparesis who showed high signal in the cervical and thoracic spinal cord on T2-weighted and contrast enhancement on T1-weighted images. (orig.)

  17. Detailed T1-Weighted Profiles from the Human Cortex Measured in Vivo at 3 Tesla MRI.

    Science.gov (United States)

    Ferguson, Bart; Petridou, Natalia; Fracasso, Alessio; van den Heuvel, Martijn P; Brouwer, Rachel M; Hulshoff Pol, Hilleke E; Kahn, René S; Mandl, René C W

    2018-04-01

    Studies into cortical thickness in psychiatric diseases based on T1-weighted MRI frequently report on aberrations in the cerebral cortex. Due to limitations in image resolution for studies conducted at conventional MRI field strengths (e.g. 3 Tesla (T)) this information cannot be used to establish which of the cortical layers may be implicated. Here we propose a new analysis method that computes one high-resolution average cortical profile per brain region extracting myeloarchitectural information from T1-weighted MRI scans that are routinely acquired at a conventional field strength. To assess this new method, we acquired standard T1-weighted scans at 3 T and compared them with state-of-the-art ultra-high resolution T1-weighted scans optimised for intracortical myelin contrast acquired at 7 T. Average cortical profiles were computed for seven different brain regions. Besides a qualitative comparison between the 3 T scans, 7 T scans, and results from literature, we tested if the results from dynamic time warping-based clustering are similar for the cortical profiles computed from 7 T and 3 T data. In addition, we quantitatively compared cortical profiles computed for V1, V2 and V7 for both 7 T and 3 T data using a priori information on their relative myelin concentration. Although qualitative comparisons show that at an individual level average profiles computed for 7 T have more pronounced features than 3 T profiles the results from the quantitative analyses suggest that average cortical profiles computed from T1-weighted scans acquired at 3 T indeed contain myeloarchitectural information similar to profiles computed from the scans acquired at 7 T. The proposed method therefore provides a step forward to study cortical myeloarchitecture in vivo at conventional magnetic field strength both in health and disease.

  18. Evaluation of endometrial carcinoma by multislice dynamic MR imaging with Turbo FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Mari [Okayama Univ. (Japan). School of Medicine

    1995-04-01

    The purpose of this study was to investigate the usefulness of multislice dynamic MR imaging with Turbo FLASH in assessing myometrial invasion by endometrial carcinoma. Dynamic MR imaging was performed with bolus injection of Gd-DTPA and with 1.5-T Siemens Magnetom imager using Turbo FLASH. Thirty-six endometrial carcinomas were evaluated with pathologic correlation. Junctional zone showed more rapid contrast enhancement effects than myometrium even after menopause. Contrast to noise ratio between junctional zone and endometrial carcinoma was the highest about fifty seconds after bolus injection. Only at that time could the degree of invasion to junctional zone in post-menopausal women whose junctional zones could not be seen on T{sub 2}-weighted images or contrast-enhanced T{sub 1}-weighted images be evaluated correctly. The accuracy in assessing myometrial invasion with T{sub 2}-weighted images, postcontrast T{sub 1}-weighted images, and dynamic MR imaging was 75%, 81% and 89% respectively. Though there was no statistically significant difference, multislice dynamic imaging with Turbo FLASH technique is considered to be a useful imaging method for the pre-operative assessment of myometrial invasion by endometrial carcinoma. (author).

  19. Dynamic contrast-enhanced MR imaging of the water fraction of normal bone marrow and diffuse bone marrow disease

    Energy Technology Data Exchange (ETDEWEB)

    Katsuya, Tomoo; Inoue, Tomio; Ishizaka, Hiroshi; Aoki, Jun; Endo, Keigo [Gunma Univ., Maebashi (Japan). School of Medicine

    2000-10-01

    To clarify the contrast-enhancement pattern of the normal hematopoietic element by isolating the signal of the water fraction in vertebral bone marrow and to investigate whether this approach can be used to characterize bone marrow pathology in several diffuse bone marrow diseases. Two groups were examined: 30 normal healthy volunteers and 19 patients with primary diffuse bone marrow disease (aplastic anemia [n=8], myelodysplastic syndrome (MDS) [n=5], chronic myelogenic leukemia (CML) [n=4], polycythemia vera [n=2]). Isolation of the signal of hematopoietic tissue was done by the chemical-shift misregistration effect. Twenty consecutive T1-weighted midsagittal lumber vertebral images were obtained immediately after the intravenous administration of Gd-DTPA of 0.1 mmol/kg body weight, and the pattern of the time-intensity curve, the peak contrast-enhancement (CE) ratio, and the washout rate (%/min) of bone marrow in normal volunteers were compared with those in patients suffering from primary diffuse bone marrow disease. The pattern of the time-intensity curve of patients with aplastic anemia showed a low peak value followed by a slow washout. However, the pattern of time-intensity curves in patients with MDS, CML, and polycythemia vera was similar to that of normal volunteers. The peak CE ratio of the water fraction in normal marrow ranged from 0.45 to 1.26 (mean {+-}S.D.: 0.87{+-}0.18). Patients with aplastic anemia showed an abnormally lower peak CE ratio of the water fraction (mean {+-}S.D.: 0.34{+-}0.19, p<0.0001). On the other hand, the peak CE ratio of the water fraction in patients with MDS was significantly higher than that of normal volunteers (mean {+-}S.D. 1.35{+-}0.39, p<0.05). In contrast, the peak CE ratio of patients with CML or polycythemia vera did not differ significantly from that of normal volunteers. The mean washout rate of patients with aplastic anemia was significantly lower than that of normal volunteers (mean {+-}S.D.: 3.50{+-}2.51 %/min

  20. Dynamic contrast-enhanced MR imaging of the water fraction of normal bone marrow and diffuse bone marrow disease

    International Nuclear Information System (INIS)

    Katsuya, Tomoo; Inoue, Tomio; Ishizaka, Hiroshi; Aoki, Jun; Endo, Keigo

    2000-01-01

    To clarify the contrast-enhancement pattern of the normal hematopoietic element by isolating the signal of the water fraction in vertebral bone marrow and to investigate whether this approach can be used to characterize bone marrow pathology in several diffuse bone marrow diseases. Two groups were examined: 30 normal healthy volunteers and 19 patients with primary diffuse bone marrow disease (aplastic anemia [n=8], myelodysplastic syndrome (MDS) [n=5], chronic myelogenic leukemia (CML) [n=4], polycythemia vera [n=2]). Isolation of the signal of hematopoietic tissue was done by the chemical-shift misregistration effect. Twenty consecutive T1-weighted midsagittal lumber vertebral images were obtained immediately after the intravenous administration of Gd-DTPA of 0.1 mmol/kg body weight, and the pattern of the time-intensity curve, the peak contrast-enhancement (CE) ratio, and the washout rate (%/min) of bone marrow in normal volunteers were compared with those in patients suffering from primary diffuse bone marrow disease. The pattern of the time-intensity curve of patients with aplastic anemia showed a low peak value followed by a slow washout. However, the pattern of time-intensity curves in patients with MDS, CML, and polycythemia vera was similar to that of normal volunteers. The peak CE ratio of the water fraction in normal marrow ranged from 0.45 to 1.26 (mean ±S.D.: 0.87±0.18). Patients with aplastic anemia showed an abnormally lower peak CE ratio of the water fraction (mean ±S.D.: 0.34±0.19, p<0.0001). On the other hand, the peak CE ratio of the water fraction in patients with MDS was significantly higher than that of normal volunteers (mean ±S.D. 1.35±0.39, p<0.05). In contrast, the peak CE ratio of patients with CML or polycythemia vera did not differ significantly from that of normal volunteers. The mean washout rate of patients with aplastic anemia was significantly lower than that of normal volunteers (mean ±S.D.: 3.50±2.51 %/min vs. 7.13±1

  1. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging of bone marrow in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Hillengass, Jens (Dept. of Radiology, German Cancer Research Center, Heidelberg (Germany); Dept. of Hematology, Oncology and Rheumatology, Univ. of Heidelberg (Germany)), e-mail: j.hillengass@dkfz.de; Stieltjes, Bram (Dept. of Radiology, German Cancer Research Center, Heidelberg (Germany)); Baeuerle, Tobias (Dept. of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany)) (and others)

    2011-04-15

    Background: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) displays microcirculation and permeability by application of contrast-media and diffusion-weighted imaging (DWI) is a tool for quantification of cellularity in the investigated area. Recently published examples cover breast cancer, CNS tumors, head and neck cancer, gastrointestinal cancer, prostate cancer as well as hematologic malignancies. Purpose: To investigated the influence of age, sex, and localization of the investigated region on findings of DCE-MRI and DWI. Material and Methods: DCE-MRI-parameters amplitude A and exchange rate constant kep as well as the DWI-parameter ADC of the bone marrow of the lumbar vertebral column of 30 healthy individuals covering the typical range of age of tumor patients were evaluated. ADC was calculated using b=0 and a maximal b value of either 400 or 750 s/mm2. Results: Amplitude A of DCE-MRI decreased with age (P = 0.01) and amplitude A, exchange rate constant kep as well as ADC based on b = 400 s/mm2 and b = 750 s/mm2, respectively, decreased significantly from the first to the fifth lumbar vertebra with P = 0.02, P = 0.05, P = 0.003, and P = 0.002, respectively. Conclusion: Quantitative parameters of functional imaging techniques in bone marrow are influenced by the age of the examined individual and the anatomical location of the investigated region

  2. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging of bone marrow in healthy individuals

    International Nuclear Information System (INIS)

    Hillengass, Jens; Stieltjes, Bram; Baeuerle, Tobias

    2011-01-01

    Background: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) displays microcirculation and permeability by application of contrast-media and diffusion-weighted imaging (DWI) is a tool for quantification of cellularity in the investigated area. Recently published examples cover breast cancer, CNS tumors, head and neck cancer, gastrointestinal cancer, prostate cancer as well as hematologic malignancies. Purpose: To investigated the influence of age, sex, and localization of the investigated region on findings of DCE-MRI and DWI. Material and Methods: DCE-MRI-parameters amplitude A and exchange rate constant kep as well as the DWI-parameter ADC of the bone marrow of the lumbar vertebral column of 30 healthy individuals covering the typical range of age of tumor patients were evaluated. ADC was calculated using b=0 and a maximal b value of either 400 or 750 s/mm2. Results: Amplitude A of DCE-MRI decreased with age (P = 0.01) and amplitude A, exchange rate constant kep as well as ADC based on b = 400 s/mm 2 and b = 750 s/mm 2 , respectively, decreased significantly from the first to the fifth lumbar vertebra with P = 0.02, P = 0.05, P = 0.003, and P = 0.002, respectively. Conclusion: Quantitative parameters of functional imaging techniques in bone marrow are influenced by the age of the examined individual and the anatomical location of the investigated region

  3. Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    Science.gov (United States)

    Clavijo Jordan, M Veronica; Beeman, Scott C; Baldelomar, Edwin J; Bennett, Kevin M

    2014-01-01

    Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have limited in vivo detection due to a number of constraints with T2 or T2*-weighted imaging. T1-weighted imaging is often preferred for molecular MRI, but most T1-shortening agents are small chelates with low metal payload or are nanoparticles that also shorten T2 and limit the range of concentrations detectable with T1-weighting. Here we used tungsten and iron deposition to form doped iron oxide crystals inside the apoferritin cavity to form a WFe nanoparticle with a disordered crystal and un-coupled atomic magnetic moments. The atomic magnetic moments were thus localized, resulting in a principally paramagnetic nanoparticle. The WFe nanoparticles had no coercivity or saturation magnetization at 5 K and sweeping up to ± 20,000 Oe, while native ferritin had a coercivity of 3000 Oe and saturation at ± 20,000 Oe. This tungsten-iron crystal paramagnetism resulted in an increased WFe particle longitudinal relaxivity (r1) of 4870 mm(-1) s(-1) and a reduced transverse relaxivity (r2) of 9076 mm(-1) s(-1) compared with native ferritin. The accumulation of the particles was detected with T1-weighted MRI in concentrations from 20 to 400 nm in vivo, both injected in the rat brain and targeted to the rat kidney glomerulus. The WFe apoferritin nanoparticles were not cytotoxic up to 700 nm particle concentrations, making them potentially important for targeted molecular MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  5. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  6. Temporomandibular joint (TMJ) pain revisited with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)

    International Nuclear Information System (INIS)

    Tasali, N.; Cubuk, R.; Aricak, M.; Ozarar, M.; Saydam, B.; Nur, H.; Tuncbilek, N.

    2012-01-01

    Purpose: We aimed to assess the contrast enhancement patterns of the retrodiscal tissue with dynamic contrast-enhanced MR imaging (DCE-MRI) with respect to different temporomandibular joint disc pathologies. Additionally, we questioned the relationship between the temporomandibular joint (TMJ) pain and the contrast enhancement pattern of the retrodiscal tissue regardless of the TMJ disc position. Materials and methods: 52 joints of 26 patients (4 males and 22 females) who have pain in at least at one of their TMJ were included in this study. For the qualitative analysis, the joints were divided into four groups in terms of their disc positions: normal (1), partially displaced with or without reduction (2), totally dislocated with reduction (3) and totally dislocated without reduction (4). Besides, two different joint groups were constituted, namely the painful group and painless group according to the clinical findings without taking the TMJ disc positions into account. Quantitative analyses were made by means of measuring signal intensity ratios (SI) ratio at the retrodiscal tissue (from internal side and external side of the each joint) using DCE-MRI and these measurements were analyzed with paired samples t test to define the difference between the measurements. At the second stage, the time-dependent arithmetical mean values of the SI ratios were calculated for each joint group and significant differences between the groups were questioned using analysis of variance (ANOVA) test. Besides, painful and painless groups which were classified on the basis of the clinical data were compared according to the mean SI ratios found for each joint and the significant differences between these two groups were assessed by means of Student's T test. The results were assessed in 95% confidence interval where the significance level was p < 0.05. Results: A significant difference was observed between the internal and external contrast enhancement of the joints with partial

  7. High-intensity facial nerve lesions on T2-weighted images in chronic persistent facial nerve palsy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Dept. of Radiology, Tottori Univ. (Japan); Ishii, K. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Okitsu, T. [Dept. of Otolaryngology, Sendai City Hospital (Japan); Ogawa, T. [Dept. of Radiology, Tottori Univ. (Japan); Okudera, T. [Dept. of Radiology, Research Inst. of Brain and Blood Vessels-Akita, Akita (Japan)

    2001-05-01

    Our aim was to estimate the value of MRI in detecting irreversibly paralysed facial nerves. We examined 95 consecutive patients with a facial nerve palsy (14 with a persistent palsy, and 81 with good recovery), using a 1.0 T unit, with T2-weighted and contrast-enhanced T1-weighted images. The geniculate ganglion and tympanic segment had gave high signal on T2-weighted images in the chronic stage of persistent palsy, but not in acute palsy. The enhancement pattern of the facial nerve in the chronic persistent facial nerve palsy is similar to that in the acute palsy with good recovery. These findings suggest that T2-weighted MRI can be used to show severely damaged facial nerves. (orig.)

  8. Aggressive angiomyxoma with diffusion-weighted magnetic resonance imaging and dynamic contrast enhancement: a case report and review of the literature.

    Science.gov (United States)

    Brunelle, S; Bertucci, F; Chetaille, B; Lelong, B; Piana, G; Sarran, A

    2013-05-01

    Aggressive angiomyxoma (AA) is a rare benign soft tissue tumour usually affecting the pelvis and perineum of young women. Magnetic resonance imaging (MRI) is crucial in the management of AA patients for its diagnostic contribution and for the preoperative assessment of the actual tumour extension. Given the current development of less aggressive therapeutics associated with a higher risk of recurrence, close follow-up with MRI is fundamental after treatment. In this context, diffusion-weighted (DW) imaging has already shown high efficacy in the detection of early small relapses in prostate or rectal cancer. We report here a case of pelvic AA in a 51-year-old woman examined with dynamic contrast enhancement and DW-MRI, including apparent diffusion coefficient mapping and calculation. To our knowledge, this is the first description of DW-MRI in AA reported in the literature. Here, knowledge about imaging features of AA will be reviewed and expanded.

  9. Independent component analysis of dynamic contrast-enhanced computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Koh, T S [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Yang, X [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Bisdas, S [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Hospital, Theodor-Stern-Kai 7, D-60590 Frankfurt (Germany); Lim, C C T [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-10-07

    Independent component analysis (ICA) was applied on dynamic contrast-enhanced computed tomography images of cerebral tumours to extract spatial component maps of the underlying vascular structures, which correspond to different haemodynamic phases as depicted by the passage of the contrast medium. The locations of arteries, veins and tumours can be separately identified on these spatial component maps. As the contrast enhancement behaviour of the cerebral tumour differs from the normal tissues, ICA yields a tumour component map that reveals the location and extent of the tumour. Tumour outlines can be generated using the tumour component maps, with relatively simple segmentation methods. (note)

  10. Value of gadoxetic acid-enhanced and diffusion-weighted MR imaging in evaluation of hepatocellular carcinomas with atypical enhancement pattern on contrast-enhanced multiphasic MDCT in patients with chronic liver disease

    International Nuclear Information System (INIS)

    Kim, Hyun Su; Kim, Seong Hyun; Kang, Tae Wook; Song, Kyoung Doo; Choi, Dongil; Park, Cheol Keun

    2015-01-01

    Highlights: •We investigated imaging findings on gadoxetic acid-enhanced MRI of HCCs without the typical enhancement pattern on multiphasic MDCT. •Most HCCs showed ancillary MR findings of typical HCC. •Considerable number of HCCs showed MR enhancement pattern of typical HCC. -- Abstract: Objective: The purpose of this study was to investigate the value of enhancement kinetics and ancillary imaging findings on gadoxetic acid-enhanced and diffusion-weighted (DW) MR imaging for diagnosing hepatocellular carcinomas (HCCs) without the typical enhancement pattern on contrast-enhanced multiphasic MDCT in patients with chronic liver disease. Materials and methods: Eighty-two surgically confirmed HCCs without the typical enhancement pattern (hypervascular in the arterial phase, followed by washout on the portal or equilibrium phases) on triple-phase MDCT were enrolled in this study. The patients were classified into four categories based on the CT density pattern of arterial and equilibrium phases (isodense–isodense, hypodense–hypodense, isodense–hypodense, and hyperdense–isodense) compared to liver parenchyma. Signal intensity of HCCs on T2-weighted images (T2WI), arterial phase, 3 min late-phase, hepatobiliary phase (HBP) and DW images with a b value of 800 s/mm 2 were qualitatively evaluated, and ADC values were measured. Fisher's exact test and Chi-square test were used to compare the frequency and trend of hyperintensity on T2WI, hypointensity on HBP images, hyperintensity on DW images, and histopathologic grades between groups with different CT density patterns. Kruskal–Wallis test was used to compare the ADC value between groups. Results: Thirty and 52 HCCs were categorized as hypervascular (hyperdense–isodense) and non-hypervascular HCCs (3, isodense–isodense; 37, hypodense–hypodense; 12, isodense–hypodense), respectively. Most HCCs showed hyperintensity on T2WI (77/82, 93.9%) and DW images (81/82, 98.8%) and hypointensity on HBP images

  11. Value of gadoxetic acid-enhanced and diffusion-weighted MR imaging in evaluation of hepatocellular carcinomas with atypical enhancement pattern on contrast-enhanced multiphasic MDCT in patients with chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Su [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-gu, Seoul (Korea, Republic of); Kim, Seong Hyun, E-mail: kshyun@skku.edu [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-gu, Seoul (Korea, Republic of); Kang, Tae Wook; Song, Kyoung Doo; Choi, Dongil [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-gu, Seoul (Korea, Republic of); Park, Cheol Keun [Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-gu, Seoul 135-710 (Korea, Republic of)

    2015-04-15

    Highlights: •We investigated imaging findings on gadoxetic acid-enhanced MRI of HCCs without the typical enhancement pattern on multiphasic MDCT. •Most HCCs showed ancillary MR findings of typical HCC. •Considerable number of HCCs showed MR enhancement pattern of typical HCC. -- Abstract: Objective: The purpose of this study was to investigate the value of enhancement kinetics and ancillary imaging findings on gadoxetic acid-enhanced and diffusion-weighted (DW) MR imaging for diagnosing hepatocellular carcinomas (HCCs) without the typical enhancement pattern on contrast-enhanced multiphasic MDCT in patients with chronic liver disease. Materials and methods: Eighty-two surgically confirmed HCCs without the typical enhancement pattern (hypervascular in the arterial phase, followed by washout on the portal or equilibrium phases) on triple-phase MDCT were enrolled in this study. The patients were classified into four categories based on the CT density pattern of arterial and equilibrium phases (isodense–isodense, hypodense–hypodense, isodense–hypodense, and hyperdense–isodense) compared to liver parenchyma. Signal intensity of HCCs on T2-weighted images (T2WI), arterial phase, 3 min late-phase, hepatobiliary phase (HBP) and DW images with a b value of 800 s/mm{sup 2} were qualitatively evaluated, and ADC values were measured. Fisher's exact test and Chi-square test were used to compare the frequency and trend of hyperintensity on T2WI, hypointensity on HBP images, hyperintensity on DW images, and histopathologic grades between groups with different CT density patterns. Kruskal–Wallis test was used to compare the ADC value between groups. Results: Thirty and 52 HCCs were categorized as hypervascular (hyperdense–isodense) and non-hypervascular HCCs (3, isodense–isodense; 37, hypodense–hypodense; 12, isodense–hypodense), respectively. Most HCCs showed hyperintensity on T2WI (77/82, 93.9%) and DW images (81/82, 98.8%) and hypointensity on HBP

  12. Pretreatment Evaluation of Microcirculation by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Survival in Primary Rectal Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Alexander Friedrich [Department of Radio-Oncology, Academic Teaching Hospital Feldkirch, Feldkirch (Austria); Piringer, Gudrun, E-mail: gudrun.piringer@hotmail.com [Department of Oncology, Wels-Grieskirchen Medical Hospital, Wels (Austria); Kremser, Christian; Judmaier, Werner [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Saely, Christoph Hubert [Department of Medicine and Cardiology, Academic Teaching Hospital Feldkirch, Feldkirch (Austria); Lukas, Peter [Department of Radio-Oncology, Innsbruck Medical University, Innsbruck (Austria); Öfner, Dietmar [Department of Surgery, Paracelsus Medical University, Salzburg (Austria)

    2014-12-01

    Purpose: To investigate the prognostic value of the perfusion index (PI), a microcirculatory parameter estimated from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), which integrates information on both flow and permeability, to predict overall survival and disease-free survival in patients with primary rectal cancer. Methods and Materials: A total of 83 patients with stage cT3 rectal cancer requiring neoadjuvant chemoradiation were investigated with DCE-MRI before start of therapy. Contrast-enhanced dynamic T{sub 1} mapping was obtained, and a simple data analysis strategy based on the calculation of the maximum slope of the tissue concentration–time curve divided by the maximum of the arterial input function was used as a measure of tumor microcirculation (PI), which integrates information on both flow and permeability. Results: In 39 patients (47.0%), T downstaging (ypT0-2) was observed. During a mean (±SD) follow-up period of 71 ± 29 months, 58 patients (69.9%) survived, and disease-free survival was achieved in 45 patients (54.2%). The mean PI (PImean) averaged over the group of nonresponders was significantly higher than for responders. Additionally, higher PImean in age- and gender-adjusted analyses was strongly predictive of therapy nonresponse. Most importantly, PImean strongly and significantly predicted disease-free survival (unadjusted hazard ratio [HR], 1.85 [ 95% confidence interval, 1.35-2.54; P<.001)]; HR adjusted for age and sex, 1.81 [1.30-2.51]; P<.001) as well as overall survival (unadjusted HR 1.42 [1.02-1.99], P=.040; HR adjusted for age and sex, 1.43 [1.03-1.98]; P=.034). Conclusions: This analysis identifies PImean as a novel biomarker that is predictive for therapy response, disease-free survival, and overall survival in patients with primary locally advanced rectal cancer.

  13. Marginal erosive discovertebral ''Romanus'' lesions in ankylosing spondylitis demonstrated by contrast enhanced Gd-DTPA magnetic resonance imaging

    International Nuclear Information System (INIS)

    Jevtic, V.; Kos-Golja, M.; Rozman, B.; McCall, I.

    2000-01-01

    Objective. To assess the value of Gd-DTPA magnetic resonance (MR) imaging in the demonstration of marginal destructive discovertebral Romanus lesions in ankylosing spondylitis.Design and patients. A prospective study of Gd-DTPA MR imaging was performed in 39 patients with a clinical diagnosis of ankylosing spondylitis and typical Romanus lesions seen on radiographs of the thoracolumbar spine. MR morphological appearances and signal intensity changes at the discovertebral junctions were analysed and compared with the radiographic findings.Results. Ninety-nine discovertebral junctions with Romanus lesions showed low signal intensity on T1-weighted and high signal on T2-weighted and T1-weighted postcontrast images at the vertebral corners consistent with oedematous hyperaemic inflammatory tissue. There were nine discovertebral junctions with similar MR findings but normal radiographs. Fifty-three discovertebral junctions showed syndesmophyte formation with increased signal intensity on both T1- and T2-weighted images with no contrast enhancement. Sixty-five discovertebral junctions showed a mixture of radiographic features and varied high and low signal changes at the vertebral rim on MR imaging with rims of enhancement in the vertebral body following contrast administration.Conclusion. Gd-DTPA MR imaging demonstrates a variable signal pattern and degree of contrast enhancement which may reflect the evolutionary stages of discovertebral enthesitis in ankylosing spondylitis. MR imaging may identify early erosive changes in radiographically normal vertebra. The role of MR imaging needs further investigation. (orig.)

  14. Modifications in dynamic contrast-enhanced magnetic resonance imaging parameters after α-particle-emitting ²²⁷Th-trastuzumab therapy of HER2-expressing ovarian cancer xenografts.

    Science.gov (United States)

    Heyerdahl, Helen; Røe, Kathrine; Brevik, Ellen Mengshoel; Dahle, Jostein

    2013-09-01

    The purpose of this study was to investigate the effect of α-particle-emitting (227)Th-trastuzumab radioimmunotherapy on tumor vasculature to increase the knowledge about the mechanisms of action of (227)Th-trastuzumab. Human HER2-expressing SKOV-3 ovarian cancer xenografts were grown bilaterally in athymic nude mice. Mice with tumor volumes 253 ± 36 mm(3) (mean ± SEM) were treated with a single injection of either (227)Th-trastuzumab at a dose of 1000 kBq/kg body weight (treated group, n=14 tumors) or 0.9% NaCl (control group, n=10 tumors). Dynamic T1-weighted contrast-enhanced magnetic resonance imaging (DCEMRI) was used to study the effect of (227)Th-trastuzumab on tumor vasculature. DCEMRI was performed before treatment and 1, 2, and 3 weeks after therapy. Tumor contrast-enhancement curves were extracted voxel by voxel and fitted to the Brix pharmacokinetic model. Pharmacokinetic parameters for the tumors that underwent radioimmunotherapy were compared with the corresponding parameters of control tumors. Significant increases of kep, the rate constant of diffusion from the extravascular extracellular space to the plasma (PTh-trastuzumab treatment of HER2-expressing ovarian cancer xenografts. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Characterization of liver metastases: the efficacy of biphasic magnetic resonance imaging with ferucarbotran-enhancement

    International Nuclear Information System (INIS)

    Hong, H.S.; Byun, J.H.; Won, H.J.; Kim, K.W.; Lee, S.S.; Lee, M.G.; Yun, S.C.

    2010-01-01

    Aim: To retrospectively evaluate the efficacy of biphasic magnetic resonance imaging (MRI) of the liver with ferucarbotran-enhancement for the characterization of hepatic metastases. Materials and methods: Thirty-six patients underwent MRI of the liver with separate acquisition of double-contrast enhancement consisting of gadolinium and ferucarbotran. A total of 106 focal hepatic lesions (51 metastases, 31 cysts, 23 haemangiomas, and one eosinophilic abscess) were included. Two sets of MRI were analysed: (1) ferucarbotran set: ferucarbotran-enhanced T1-weighted (T1W) dynamic imaging combined with ferucarbotran-enhanced T2*-weighted (T2*W) delayed imaging and (2) double set: gadolinium-enhanced T1W dynamic imaging combined with ferucarbotran-enhanced T2*W delayed imaging. The diagnostic accuracy of the two sets was evaluated using alternative free-response receiver operating characteristic curve analysis. Sensitivity and specificity were compared using the McNemar test. The enhancement pattern of focal hepatic lesions was analysed on gadolinium and ferucarbotran-enhanced T1W dynamic imaging. Results: There was no significant difference in the accuracy of characterizing hepatic metastases between the two sets. Sensitivity and specificity were not significantly different between the sets (p > 0.05). Peripheral rim enhancement was exhibited in 57% of metastatic lesions on ferucarbotran-enhanced T1W dynamic imaging. The majority (96%) of hepatic haemangiomas demonstrated typical peripheral nodular enhancement with progression on ferucarbotran-enhanced T1W dynamic imaging and were easily differentiated from metastases. Conclusion: Biphasic MRI of the liver with ferucarbotran-enhancement alone provided comparable diagnostic efficacy to double-contrast MRI for the characterization of hepatic metastases.

  16. Comparison of MR imaging after administration of dysprosium-based magnetic-susceptibility contrast media with diffusion-weighted MR imaging in evaluation of regional cerebral ischemia

    International Nuclear Information System (INIS)

    Moseley, M.E.; Kucharczyk, J.; Kurhanewicz, J.; Mintorovitch, J.; Cohen, Y.; Rocklage, S.; Quay, S.C.; Norman, D.

    1989-01-01

    This paper reports on a study to establish whether a nonionic T2-shortening contrast agent, Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA), would facilitate early detection of stroke-induced cerebral perfusion deficits. The sensitivity of susceptibility-enhanced MR imaging was compared with that of diffusion-weighted MR imaging in the same cats subjected to unilateral occlusion of the middle cerebral artery (MCA). A 2-T unit, equipped with self-shielded gradient coils (± 20 G/cm, 15-cm bore size), was used in conjunction with an 8.5-cm inner diameter low-pass bird cage proton imaging coil. Diffusion-weighted images displayed increased signal intensity in the ischemic MCA territory less than 1 hour after occlusion, whereas T2-weighted MR images without contrast enhancement usually failed to depict injury for 2--3 hours after toke. With contrast administration (0.5 mmoles/kg of Dy-DTPA-BMA), however, T2-weighted images revealed perfusion deficits (hyperintensity) within 1 hour after MCA occlusion, and these corresponded to the anatomic regions of ischemic injury shown on diffusion-weighted MR images

  17. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  18. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with 18F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Suenaga, Yuko; Ueno, Yoshiko; Kanda, Tomonori; Maeda, Tetsuo; Takahashi, Satoru; Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto; Sugimura, Kazuro

    2013-01-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer

  19. The Role of Dynamic Contrast-Enhanced MRI in a Child with Sport-Induced Avascular Necrosis of the Scaphoid: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Baris Beytullah Koc

    2016-01-01

    Full Text Available Avascular necrosis (AVN of the scaphoid in children is very rare and there is currently no consensus when conservative or operative treatment is indicated. A 10-year-old boy, practicing karate, presented with acute pain in his left wrist after falling on the outstretched hand. Imaging showed a scaphoid waist fracture with signs of an ongoing AVN. The diagnosis of AVN was confirmed with signal loss of the scaphoid on MRI T1. A dynamic contrast-enhanced MRI was performed for further assessment of the proximal pole vascularity and treatment planning. As dynamic contrast-enhanced MRI showed fair perfusion of the proximal pole, an adequate healing potential with conservative treatment was estimated. We achieved union and good function with cast immobilization for fourteen weeks. This case study showed dynamic contrast-enhanced MRI to be a valuable tool in assessing whether conservative or operative treatment is indicated to achieve union and good functional outcome.

  20. TU-F-CAMPUS-J-02: Evaluation of Textural Feature Extraction for Radiotherapy Response Assessment of Early Stage Breast Cancer Patients Using Diffusion Weighted MRI and Dynamic Contrast Enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Y; Wang, C; Horton, J; Chang, Z [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To investigate the feasibility of using classic textural feature extraction in radiotherapy response assessment, we studied a unique cohort of early stage breast cancer patients with paired pre - and post-radiation Diffusion Weighted MRI (DWI-MRI) and Dynamic Contrast Enhanced MRI (DCE-MRI). Methods: 15 female patients from our prospective phase I trial evaluating preoperative radiotherapy were included in this retrospective study. Each patient received a single-fraction radiation treatment, and DWI and DCE scans were conducted before and after the radiotherapy. DWI scans were acquired using a spin-echo EPI sequence with diffusion weighting factors of b = 0 and b = 500 mm{sup 2} /s, and the apparent diffusion coefficient (ADC) maps were calculated. DCE-MRI scans were acquired using a T{sub 1}-weighted 3D SPGR sequence with a temporal resolution of about 1 minute. The contrast agent (CA) was intravenously injected with a 0.1 mmol/kg bodyweight dose at 2 ml/s. Two parameters, volume transfer constant (K{sup trans} ) and k{sub ep} were analyzed using the two-compartment Tofts kinetic model. For DCE parametric maps and ADC maps, 33 textural features were generated from the clinical target volume (CTV) in a 3D fashion using the classic gray level co-occurrence matrix (GLCOM) and gray level run length matrix (GLRLM). Wilcoxon signed-rank test was used to determine the significance of each texture feature’s change after the radiotherapy. The significance was set to 0.05 with Bonferroni correction. Results: For ADC maps calculated from DWI-MRI, 24 out of 33 CTV features changed significantly after the radiotherapy. For DCE-MRI pharmacokinetic parameters, all 33 CTV features of K{sup trans} and 33 features of k{sub ep} changed significantly. Conclusion: Initial results indicate that those significantly changed classic texture features are sensitive to radiation-induced changes and can be used for assessment of radiotherapy response in breast cancer.

  1. IgG4-related kidney disease: MRI findings with emphasis on the usefulness of diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bohyun; Kim, Jin Hee, E-mail: kimjhrad@amc.seoul.kr; Byun, Jae Ho; Kim, Hyoung Jung; Lee, Seung Soo; Kim, So Yeon; Lee, Moon-Gyu

    2014-07-15

    Objectives: To investigate the imaging findings of immunoglobulin G4 (IgG4)-related kidney disease (IgG4-KD) on magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) and to evaluate the usefulness of DWI in lesion detection. Methods: This retrospective cohort study included 31 patients with IgG4-KD who underwent MRI covering both kidneys. Two radiologists reviewed in consensus the MR images to determine the distribution pattern (location, laterality, and multiplicity) and the visually assessed signal intensity (hypointense, isointense or hyperintense) of the renal lesions compared to the normal renal parenchyma on each sequence. Per-patient sensitivity for detecting IgG4-KD and the number of detectable lesions were compared in T2-weighted images, DWI, and dynamic contrast-enhanced images. Results: IgG4-KD typically manifested as bilateral (83.9%), multiple (93.5%), and renal parenchymal (87.1%) nodules appearing isointense (93.5%) on T1-weighted images, hypointense (77.4%) on T2-weighted images, hyperintense (100%) on DWI (b = 1000), and hypointense (83.3%) in the arterial phase and with a progressive enhancement pattern on dynamic contrast-enhanced images. The sensitivity of DWI for detecting IgG4-KD was significantly higher than that of T2-weighted images (100% vs. 77.4%, P = 0.034). The median number of detectable lesions was significantly greater in DWI (n = 9) than in T2-weighted images (n = 2) and dynamic contrast-enhanced images (n = 5) (P ≤ 0.008). Conclusions: The characteristic MRI findings of IgG4-KD were bilateral, multiple, renal parenchymal nodules with T2 hypointensity, diffusion restriction, and a progressive enhancement pattern. As DWI was useful in the detection of IgG4-KD, adding DWI to conventional MRI for patients suspected of having IgG4-KD may enhance the diagnosis.

  2. IgG4-related kidney disease: MRI findings with emphasis on the usefulness of diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Kim, Bohyun; Kim, Jin Hee; Byun, Jae Ho; Kim, Hyoung Jung; Lee, Seung Soo; Kim, So Yeon; Lee, Moon-Gyu

    2014-01-01

    Objectives: To investigate the imaging findings of immunoglobulin G4 (IgG4)-related kidney disease (IgG4-KD) on magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) and to evaluate the usefulness of DWI in lesion detection. Methods: This retrospective cohort study included 31 patients with IgG4-KD who underwent MRI covering both kidneys. Two radiologists reviewed in consensus the MR images to determine the distribution pattern (location, laterality, and multiplicity) and the visually assessed signal intensity (hypointense, isointense or hyperintense) of the renal lesions compared to the normal renal parenchyma on each sequence. Per-patient sensitivity for detecting IgG4-KD and the number of detectable lesions were compared in T2-weighted images, DWI, and dynamic contrast-enhanced images. Results: IgG4-KD typically manifested as bilateral (83.9%), multiple (93.5%), and renal parenchymal (87.1%) nodules appearing isointense (93.5%) on T1-weighted images, hypointense (77.4%) on T2-weighted images, hyperintense (100%) on DWI (b = 1000), and hypointense (83.3%) in the arterial phase and with a progressive enhancement pattern on dynamic contrast-enhanced images. The sensitivity of DWI for detecting IgG4-KD was significantly higher than that of T2-weighted images (100% vs. 77.4%, P = 0.034). The median number of detectable lesions was significantly greater in DWI (n = 9) than in T2-weighted images (n = 2) and dynamic contrast-enhanced images (n = 5) (P ≤ 0.008). Conclusions: The characteristic MRI findings of IgG4-KD were bilateral, multiple, renal parenchymal nodules with T2 hypointensity, diffusion restriction, and a progressive enhancement pattern. As DWI was useful in the detection of IgG4-KD, adding DWI to conventional MRI for patients suspected of having IgG4-KD may enhance the diagnosis

  3. Dynamic contrast-enhanced MRI evaluation of cerebral cavernous malformations.

    Science.gov (United States)

    Hart, Blaine L; Taheri, Saeid; Rosenberg, Gary A; Morrison, Leslie A

    2013-10-01

    The aim of this study is to quantitatively evaluate the behavior of CNS cavernous malformations (CCMs) using a dynamic contrast-enhanced MRI (DCEMRI) technique sensitive for slow transfer rates of gadolinium. The prospective study was approved by the institutional review board and was HIPPA compliant. Written informed consent was obtained from 14 subjects with familial CCMs (4 men and 10 women, ages 22-76 years, mean 48.1 years). Following routine anatomic MRI of the brain, DCEMRI was performed for six slices, using T1 mapping with partial inversion recovery (TAPIR) to calculate T1 values, following administration of 0.025 mmol/kg gadolinium DTPA. The transfer rate (Ki) was calculated using the Patlak model, and Ki within CCMs was compared to normal-appearing white matter as well as to 17 normal control subjects previously studied. All subjects had typical MRI appearance of CCMs. Thirty-nine CCMs were studied using DCEMRI. Ki was low or normal in 12 lesions and elevated from 1.4 to 12 times higher than background in the remaining 27 lesions. Ki ranged from 2.1E-6 to 9.63E-4 min(-1), mean 3.55E-4. Normal-appearing white matter in the CCM patients had a mean Ki of 1.57E-4, not statistically different from mean WM Ki of 1.47E-4 in controls. TAPIR-based DCEMRI technique permits quantifiable assessment of CCMs in vivo and reveals considerable differences not seen with conventional MRI. Potential applications include correlation with biologic behavior such as lesion growth or hemorrage, and measurement of drug effects.

  4. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  5. Brain tumours at 7T MRI compared to 3T - contrast effect after half and full standard contrast agent dose: initial results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Weber, M.; Szomolanyi, P.; Juras, V.; Kronnerwetter, C.; Widhalm, G.; Nemec, S.; Prayer, D.; Ladd, M.E.; Trattnig, S.

    2015-01-01

    To compare the contrast agent effect of a full dose and half the dose of gadobenate dimeglumine in brain tumours at 7 Tesla (7T) MR versus 3 Tesla (3T). Ten patients with primary brain tumours or metastases were examined. Signal intensities were assessed in the lesion and normal brain. Tumour-to-brain contrast and lesion enhancement were calculated. Additionally, two independent readers subjectively graded the image quality and artefacts. The enhanced mean tumour-to-brain contrast and lesion enhancement were significantly higher at 7T than at 3T for both half the dose (91.8 ± 45.8 vs. 43.9 ± 25.3 [p = 0.010], 128.1 ± 53.7 vs. 75.5 ± 32.4 [p = 0.004]) and the full dose (129.2 ± 50.9 vs. 66.6 ± 33.1 [p = 0.002], 165.4 ± 54.2 vs. 102.6 ± 45.4 [p = 0.004]). Differences between dosages at each field strength were also significant. Lesion enhancement was higher with half the dose at 7T than with the full dose at 3T (p =.037), while the tumour-to-brain contrast was not significantly different. Subjectively, contrast enhancement, visibility, and lesion delineation were better at 7T and with the full dose. All parameters were rated as good, at the least. Half the routine contrast agent dose at 7T provided higher lesion enhancement than the full dose at 3T which indicates the possibility of dose reduction at 7T. (orig.)

  6. Brain tumours at 7T MRI compared to 3T - contrast effect after half and full standard contrast agent dose: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie; Weber, M. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Division of Neuroradiology and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Szomolanyi, P.; Juras, V. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Kronnerwetter, C. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Widhalm, G. [Medical University of Vienna, Department of Neurosurgery, Vienna (Austria); Nemec, S.; Prayer, D. [Medical University of Vienna, Division of Neuroradiology and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ladd, M.E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology, Heidelberg (Germany); Trattnig, S. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-01-15

    To compare the contrast agent effect of a full dose and half the dose of gadobenate dimeglumine in brain tumours at 7 Tesla (7T) MR versus 3 Tesla (3T). Ten patients with primary brain tumours or metastases were examined. Signal intensities were assessed in the lesion and normal brain. Tumour-to-brain contrast and lesion enhancement were calculated. Additionally, two independent readers subjectively graded the image quality and artefacts. The enhanced mean tumour-to-brain contrast and lesion enhancement were significantly higher at 7T than at 3T for both half the dose (91.8 ± 45.8 vs. 43.9 ± 25.3 [p = 0.010], 128.1 ± 53.7 vs. 75.5 ± 32.4 [p = 0.004]) and the full dose (129.2 ± 50.9 vs. 66.6 ± 33.1 [p = 0.002], 165.4 ± 54.2 vs. 102.6 ± 45.4 [p = 0.004]). Differences between dosages at each field strength were also significant. Lesion enhancement was higher with half the dose at 7T than with the full dose at 3T (p =.037), while the tumour-to-brain contrast was not significantly different. Subjectively, contrast enhancement, visibility, and lesion delineation were better at 7T and with the full dose. All parameters were rated as good, at the least. Half the routine contrast agent dose at 7T provided higher lesion enhancement than the full dose at 3T which indicates the possibility of dose reduction at 7T. (orig.)

  7. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    International Nuclear Information System (INIS)

    Yoon, Hyun Jung; Yoon, Young Cheol; Choe, Bong Keun

    2014-01-01

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  8. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hyun Jung; Yoon, Young Cheol [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choe, Bong Keun [Department of Preventive Medicine, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  9. Atypical focal non-neoplastic brain changes in neurofibromatosis type 1: mass effect and contrast enhancement

    International Nuclear Information System (INIS)

    Raininko, R.; Thelin, L.; Eeg-Olofsson, O.

    2001-01-01

    Abstract Children and young adults with neurofibromatosis type 1 often have small high-signal foci on T2-weighted images of the brain. We describe follow-up of two patients in whom one of the foci had atypical features, commonly regarded as signs of a neoplasm. In the first, one lesion showed temporary contrast enhancement and decreasing mass effect. The second developed an expanding lesion that increased minimally in size over 4.5 year's follow-up. The borderline between neoplastic and non-neoplastic lesions seems to be indistinct. (orig.)

  10. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  11. The optimal use of contrast agents at high field MRI

    International Nuclear Information System (INIS)

    Trattnig, Siegfried; Pinker, Kathia; Ba-Ssalamah, Ahmed; Noebauer-Huhmann, Iris-Melanie

    2006-01-01

    The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications. (orig.)

  12. Dynamic MR imaging of pancreatic cancer

    International Nuclear Information System (INIS)

    Akaki, Shiro; Kohno, Yoshihiro; Gohbara, Hideo

    1994-01-01

    Dynamic MRI was performed on 21 patients with pancreatic duct cell carcinoma. Turbo-FLASH or FLASH3D was performed immediately following rapid bolus injection of gadopentetate dimeglumine, and these FLASH images and conventional spin echo images were evaluated about detectability of the lesion. All images were classified into three groups of detectability of the lesion ; good, fair, and poor. On T 1 weighted image, 23% of cases were 'good' and 48% were evaluated as 'fair'. On the other hand, on dynamic MRI, 62% of cases were 'good' and 33% of cases were evaluated as 'fair'. Both T 2 weighted image and enhanced T 1 weighted image were not useful for depiction of the lesion. Direct comparison between T 1 weighted image and dynamic MRI was also done. In 55% of cases, dynamic MRI was superior to T 1 weighted image and in 40% of cases, dynamic MRI was equal to T 1 weighted image. Thus, dynamic MRI was superior to conventional spin echo images for detection of duct cell carcinoma. In 17 patients of duct cell carcinoma who underwent FLASH3D, contrast/noise ratio (CNR) was calculated before and after injection of gadopentetate dimeglumine. The absolute value of CNR became significantly larger by injection of contrast material. In nine resectable pancreatic carcinomas, two cases of INF α and two cases of medullary type were well depicted. It was concluded that dynamic MRI was useful for evaluation of pancreatic carcinoma. (author)

  13. Gadolinium-enhanced dynamic magnetic resonance imaging with endorectal coil for local staging of rectal cancer

    International Nuclear Information System (INIS)

    Tamakawa, Mitsuharu; Kawaai, Yuriko; Shirase, Ryuji

    2010-01-01

    The aim of this study was to evaluate the accuracy of dynamic gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) with endorectal coil for assessing tumor invasion based on simple classification criteria. A total of 58 patients with operable primary rectal cancer underwent preoperative MRI. An enhancement pattern in Gd-enhanced dynamic MRI with regard to tumor penetration was clarified. Retrospectively, two observers independently scored T2-weighted MRI and T2-weighted MRI combined with Gd-enhanced dynamic MRI for tumor penetration using the following criteria: With Gd-enhanced dynamic MRI, T1 tumors showed an early enhanced line around the tumor as rim enhancement; T2 tumors appeared as black lines or double layers, as the muscularis propria kept its integrity; T3 tumors showed partial discontinuity of the muscularis propria as a dotted line and a perforated area as an interrupted line. A confidence level scoring system was used, and receiver operating characteristic curves were generated. There were no significant differences at the T1 stage. There were significant differences for observer 1 (P=0.001 for observer 1) at the T2 stage. There were significant differences for both observers (P=0.001 for observer 1 and P=0.005 for observer 2) at the T3 stage. Our criteria for Gd-enhanced dynamic MRI were effective for T3 stage tumors. (author)

  14. Aggressive Angiomyxoma with Diffusion-Weighted Magnetic Resonance Imaging and Dynamic Contrast Enhancement: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    S. Brunelle

    2013-07-01

    Full Text Available Introduction: Aggressive angiomyxoma (AA is a rare benign soft tissue tumour usually affecting the pelvis and perineum of young women. Magnetic resonance imaging (MRI is crucial in the management of AA patients for its diagnostic contribution and for the preoperative assessment of the actual tumour extension. Given the current development of less aggressive therapeutics associated with a higher risk of recurrence, close follow-up with MRI is fundamental after treatment. In this context, diffusion-weighted (DW imaging has already shown high efficacy in the detection of early small relapses in prostate or rectal cancer. Case Report: We report here a case of pelvic AA in a 51-year-old woman examined with dynamic contrast enhancement and DW-MRI, including apparent diffusion coefficient mapping and calculation. Conclusions: To our knowledge, this is the first description of DW-MRI in AA reported in the literature. Here, knowledge about imaging features of AA will be reviewed and expanded.

  15. T1-T2 dual-modal MRI of brain gliomas using PEGylated Gd-doped iron oxide nanoparticles.

    Science.gov (United States)

    Xiao, Ning; Gu, Wei; Wang, Hao; Deng, Yunlong; Shi, Xin; Ye, Ling

    2014-03-01

    To overcome the negative contrast limitations of iron oxide-based contrast agents and to improve the biocompatibility of Gd-chelate contrast agents, PEGylated Gd-doped iron oxide (PEG-GdIO) NPs as a T1-T2 dual-modal contrast agent were synthesized by the polyol method. The transverse relaxivity (r2) and longitudinal relaxivity (r1) of PEG-GdIO were determined to be 66.9 and 65.9 mM(-1) s(-1), respectively. The high r1 value and low r2/r1 ratio make PEG-GdIO NPs suitable as a T1-T2 dual-modal contrast agent. The in vivo MRI demonstrated a brighter contrast enhancement in T1-weighted image and a simultaneous darken effect in T2-weighted MR image compared to the pre-contrast image in the region of glioma. Furthermore, the biocompatibility of PEG-GdIO NPs was confirmed by the in vitro MTT cytotoxicity and in vivo histological analyses (H&E). Therefore, PEG-GdIO NPs hold great potential in T1-T2 dual-modal imaging for the diagnosis of brain glioma. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Malignant pleural disease: diagnosis by using diffusion-weighted and dynamic contrast-enhanced MR imaging--initial experience.

    Science.gov (United States)

    Coolen, Johan; De Keyzer, Frederik; Nafteux, Philippe; De Wever, Walter; Dooms, Christophe; Vansteenkiste, Johan; Roebben, Ilse; Verbeken, Eric; De Leyn, Paul; Van Raemdonck, Dirk; Nackaerts, Kristiaan; Dymarkowski, Steven; Verschakelen, Johny

    2012-06-01

    To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. DW imaging is a promising tool for differentiating MPD from benign lesions, with high

  17. Digital subtraction in gadolinium-enhanced MR imaging of the brain: a method to reduce contrast dosage

    International Nuclear Information System (INIS)

    Chan, J.H.M.; Tsui, E.Y.K.; Chan, C.Y.; Lai, K.F.; Cheung, Y.K.; Wong, K.P.C.; Yuen, M.K.; Chau, L.F.; Fong, D.; Mok, C.K.

    2002-01-01

    The aim of the study was to investigate the feasibility of using digital subtraction in contrast-enhanced MR imaging of the brain to reduce the MR contrast dosage without jeopardizing patient care. Fifty-two patients with intracranial lesions, either intra-axial or extra-axial, detected by computerized tomography were selected for contrast-enhanced MR imaging with half-dose and full-dose of gadopentetate dimeglumine. The half-dose unsubtracted, full-dose unsubtracted, and half-dose subtracted MR images were visually assessed by counting the number of enhancing brain lesions in the images and quantitatively analyzed by computing their lesion contrast-to-background ratios (CBR). The visual conspicuity of the half-dose subtracted MR images was comparable to that of the full-dose unsubtracted MR images (p>0.05), whereas the CBR of the half-dose subtracted images was approximately two to three times higher than that of the full-dose unsubtracted images. The half-dose subtracted T1-weighted spin-echo images might be able to replace the conventional standard-dose T1-weighted spin-echo images in MR imaging of the brain. (orig.)

  18. Comparison of gadolinium-EOB-DTPA-enhanced and diffusion-weighted liver MRI for detection of small hepatic metastases.

    Science.gov (United States)

    Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori

    2010-11-01

    To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.

  19. T1 Gd-enhanced compared with CISS sequences in retinoblastoma: superiority of T1 sequences in evaluation of tumour extension

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, Elke R.; Wanke, Isabel; Guengoer, Ali-Riza; Forsting, Michael [University Hospital, Department of Diagnostic and Interventional Neuroradiology, Essen (Germany); Jurklies, Christine [University Hospital Essen, Department of Ophthalmology (Germany)

    2005-01-01

    Background As adequate therapy for retinoblastoma in young children depends on infiltration of extra-retinal structures, diagnostic modalities play an essential role. Methods: In this widely extended study, 80 children with retinoblastoma were studied with MRI (standard fat-suppressed Gd-enhanced T1, T2 thin-slice sequences (additionally with small loop surface coil), constructive interference in steady state (CISS) sequence covering the orbita). The images were analysed by two blinded neuroradiologists. Histology was used as the gold standard. MRI assumed infiltration of extra-retinal structures in 13 of 80 patients of which ten were confirmed by histology. Affected extra-retinal structures were: optic nerve (five, of which two were on CISS and three on T1 with higher image resolution using the surface coil), scleral infiltration (five, of which four on CISS and T1) and ciliary body infiltration (one on CISS and T1). Another 61 enucleated patients did not have any extra-retinal infiltration in histology. The CISS sequence with multiplanar reconstruction was mainly helpful in revealing exact three-dimensional tumour extension with excellent clinical acceptance and pre-surgical planning but T1 fat-suppressed Gd-enhanced images were superior in revealing exact tumour extension. CISS sequences allow to produce excellent anatomical images and to perform multiplanar reconstruction to better demonstrate tumour extension. However, T1-weighted sequences after contrast application are more sensitive (60 versus 40%) in detecting infiltration of the optic nerve but equal in detecting scleral infiltration. (orig.)

  20. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI

    International Nuclear Information System (INIS)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P.; Zeman, F.; Teufel, A.; Lang, S.

    2015-01-01

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  1. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with {sup 18}F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Suenaga, Yuko; Ueno, Yoshiko [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Kanda, Tomonori [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Maeda, Tetsuo; Takahashi, Satoru [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University School of Medicine, Kobe (Japan)

    2013-10-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer.

  2. Diagnostic accuracy of automatic normalization of CBV in glioma grading using T1- weighted DCE-MRI.

    Science.gov (United States)

    Sahoo, Prativa; Gupta, Rakesh K; Gupta, Pradeep K; Awasthi, Ashish; Pandey, Chandra M; Gupta, Mudit; Patir, Rana; Vaishya, Sandeep; Ahlawat, Sunita; Saha, Indrajit

    2017-12-01

    Aim of this retrospective study was to compare diagnostic accuracy of proposed automatic normalization method to quantify the relative cerebral blood volume (rCBV) with existing contra-lateral region of interest (ROI) based CBV normalization method for glioma grading using T1-weighted dynamic contrast enhanced MRI (DCE-MRI). Sixty patients with histologically confirmed gliomas were included in this study retrospectively. CBV maps were generated using T1-weighted DCE-MRI and are normalized by contralateral ROI based method (rCBV_contra), unaffected white matter (rCBV_WM) and unaffected gray matter (rCBV_GM), the latter two of these were generated automatically. An expert radiologist with >10years of experience in DCE-MRI and a non-expert with one year experience were used independently to measure rCBVs. Cutoff values for glioma grading were decided from ROC analysis. Agreement of histology with rCBV_WM, rCBV_GM and rCBV_contra respectively was studied using Kappa statistics and intra-class correlation coefficient (ICC). The diagnostic accuracy of glioma grading using the measured rCBV_contra by expert radiologist was found to be high (sensitivity=1.00, specificity=0.96, pnormalization method showed same percentage of agreement for both expert and non-expert user. rCBV_WM showed an agreement of 88.33% (kappa=0.76,pnormalization of CBV using the proposed method could provide better diagnostic accuracy compared to the manual contralateral based approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Angiogenesis and dynamic contrast enhanced MRI of benign and malignant breast lesions: preliminary results

    International Nuclear Information System (INIS)

    Liu Peifang; Bao Runxian; Niu Yun; Yu Yong

    2002-01-01

    Objective: To determine whether dynamic contrast enhanced MRI features of early-phase enhancement rate, enhancement amplitude, and signal intensity (SI) time course are associated with the microvessel density (MVD) and vascular endothelial growth factor (VEGF) expression of malignant and benign breast lesions. Methods: Thirty-eight patients with histopathologically verified breast lesions underwent dynamic contrast enhanced MRI. SI changes during dynamic scanning were assessed quantitatively. Early-phase enhancement rate and enhancement amplitude were calculated. Time-SI curves of the lesions were obtained and classified according to their shapes as type I (which was steady enhancement to the end of the dynamic data acquisition at 7.5 min), type II (plateau of SI after avid initial contrast enhancement), or type III (washout of SI after avid initial contrast enhancement). the mean MVD and VEGF expression of the lesions were measured with immuno-histochemical staining method in all the histologic specimens by pathologists without the knowledge of the results of the MR examination. The relationships among dynamic contrast enhanced MRI features, MVD, and VEGF expression of benign and malignant breast lesions were analyzed. Results: Histology revealed 21 malignancies and 17 benign lesions. The mean MVD and VEGF expression for 21 malignant lesions were statistically higher than the mean MVD and VEGF expression for 17 benign lesions. High VEGF expression of benign and malignant breast lesions showed an association with increased MVD. Among all 38 lesions, greater (> 60%) MR early-phase enhancement rate and time-SI curve type II and III showed an association with increased MVD and higher VEGF expression level. All the differences mentioned above showed statistical significance except that the difference between VEGF expression and the distribution of curve types had no statistical significance. No significant relationships were observed between the mean of enhancement

  4. T1-weighted MRI for the detection of coronary artery plaque haemorrhage

    International Nuclear Information System (INIS)

    Oei, May Lin; Ozgun, Murat; Seifarth, Harald; Bunck, Alexander; Fischbach, Roman; Heindel, Walter; Maintz, David; Orwat, Stefan; Botnar, Rene

    2010-01-01

    Hyperintense areas in atherosclerotic plaques on pre-contrast T1-weighted MRI have been shown to correlate with intraplaque haemorrhage. We evaluated the presence of T1 hyperintensity in coronary artery plaques in coronary artery disease (CAD) patients and correlated results with multi-detector computed tomography (MDCT) findings. Fifteen patients with CAD were included. Plaques detected by MDCT were categorised based on their Hounsfield number. T1-weighted inversion recovery (IR) MRI prepared coronary MRI for the detection of plaque and steady-state free-precession coronary MR-angiography for anatomical correlation was performed. After registration of MDCT and MRI, regions of interest were defined on MDCT-visible plaques and in corresponding vessel segments acquired with MRI. MDCT density and MR signal measurement were performed in each plaque. Forty-three plaques were identified with MDCT. With IR-MRI 5/43 (12%) plaques were hyperintense, 2 of which were non-calcified and 3 mixed. Average signal-to-noise and contrast-to-noise ratios of hyperintense plaques were 15.7 and 9.1, compared with 5.6 and 1.2 for hypointense plaques. Hyperintense plaques exhibited a significantly lower CT density than hypointense plaques (63.6 vs. 140.8). There was no correlation of plaque signal intensity with degree of stenosis. T1-weighted IR-MRI may be useful for non-invasive detection and characterisation of intraplaque haemorrhage in coronary artery plaques. (orig.)

  5. Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    Science.gov (United States)

    Abakumova, Tatiana; Abakumov, Maxim; Shein, Sergey; Chelushkin, Pavel; Bychkov, Dmitry; Mukhin, Vladimir; Yusubalieva, Gaukhar; Grinenko, Nadezhda; Kabanov, Alexander; Nukolova, Natalia; Chekhonin, Vladimir

    2016-01-01

    Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive astrocytes and migrating glioma cells. The purpose of this study was to synthesize a Gd-based contrast agent conjugated with specific antibodies to Cx43 for efficient visualization of glioma C6 in vivo. We have prepared stable nontoxic conjugates of monoclonal antibody to Cx43 and polylysine-DTPA ligands complexed with Gd(III), which are characterized by higher T1 relaxivity (6.5 mM(-1) s(-1) at 7 T) than the commercial agent Magnevist® (3.4 mM(-1) s(-1)). Cellular uptake of Cx43-specific T1 contrast agent in glioma C6 cells was more than four times higher than the nonspecific IgG-contrast agent, as detected by flow cytometry and confocal analysis. MRI experiments showed that the obtained agents could markedly enhance visualization of glioma C6 in vivo after their intravenous administration. Significant accumulation of Cx43-targeted contrast agents in glioma and the peritumoral zone led not only to enhanced contrast but also to improved detection of the tumor periphery. Fluorescence imaging confirmed notable accumulation of Cx43-specific conjugates in the peritumoral zone compared with nonspecific IgG conjugates at 24 h after intravenous injection. All these features of Cx43-targeted contrast agents might be useful for more precise diagnosis of glioma and its borders by MRI. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  7. Modifications in Dynamic Contrast-Enhanced Magnetic Resonance Imaging Parameters After α-Particle-Emitting {sup 227}Th-trastuzumab Therapy of HER2-Expressing Ovarian Cancer Xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Heyerdahl, Helen, E-mail: Helen.Heyerdahl@rr-research.no [Department of Radiation Biology, Institute for Cancer Research, Oslo University Hospital - The Norwegian Radium Hospital, Oslo (Norway); Røe, Kathrine [Department of Oncology, Division of Medicine, Akershus University Hospital, Lørenskog (Norway); Brevik, Ellen Mengshoel [Department of Research and Development, Algeta ASA, Oslo (Norway); Dahle, Jostein [Nordic Nanovector AS, Oslo (Norway)

    2013-09-01

    Purpose: The purpose of this study was to investigate the effect of α-particle-emitting {sup 227}Th-trastuzumab radioimmunotherapy on tumor vasculature to increase the knowledge about the mechanisms of action of {sup 227}Th-trastuzumab. Methods and Materials: Human HER2-expressing SKOV-3 ovarian cancer xenografts were grown bilaterally in athymic nude mice. Mice with tumor volumes 253 ± 36 mm{sup 3} (mean ± SEM) were treated with a single injection of either {sup 227}Th-trastuzumab at a dose of 1000 kBq/kg body weight (treated group, n=14 tumors) or 0.9% NaCl (control group, n=10 tumors). Dynamic T1-weighted contrast-enhanced magnetic resonance imaging (DCEMRI) was used to study the effect of {sup 227}Th-trastuzumab on tumor vasculature. DCEMRI was performed before treatment and 1, 2, and 3 weeks after therapy. Tumor contrast-enhancement curves were extracted voxel by voxel and fitted to the Brix pharmacokinetic model. Pharmacokinetic parameters for the tumors that underwent radioimmunotherapy were compared with the corresponding parameters of control tumors. Results: Significant increases of k{sub ep}, the rate constant of diffusion from the extravascular extracellular space to the plasma (P<.05), and k{sub el,} the rate of clearance of contrast agent from the plasma (P<.01), were seen in the radioimmunotherapy group 2 and 3 weeks after injection, compared with the control group. The product of k{sub ep} and the amplitude parameter A, associated with increased vessel permeability and perfusion, was also significantly increased in the radioimmunotherapy group 2 and 3 weeks after injection (P<.01). Conclusions: Pharmacokinetic modeling of MRI contrast-enhancement curves evidenced significant alterations in parameters associated with increased tumor vessel permeability and tumor perfusion after {sup 227}Th-trastuzumab treatment of HER2-expressing ovarian cancer xenografts.

  8. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  9. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  10. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  11. A comparison of non-contrast and contrast-enhanced MRI in the initial stage of Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Harry K.W. [Texas Scottish Rite Hospital for Children, Center of Excellence in Hip Disorders, Dallas, TX (United States); University of Texas Southwestern, Department of Orthopedic Surgery, Dallas, TX (United States); Kaste, Sue [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee School of Health Sciences, Department of Radiology, Memphis, TN (United States); Dempsey, Molly; Wilkes, David [Texas Scottish Rite Hospital for Children, Department of Radiology, Dallas, TX (United States)

    2013-09-15

    A prognostic indicator of outcome for Legg-Calve-Perthes disease (LCP) is needed to guide treatment decisions during the initial stage of the disease (stage 1), before deformity occurs. Radiographic prognosticators are applicable only after fragmentation (stage II). We investigated pre- and postcontrast MRI in depicting stage I femoral head involvement. Thirty children with stage I LCP underwent non-contrast coronal T1 fast spin-echo (FSE) and corresponding postcontrast fat-suppressed T1-weighted fast spin-echo (FSE) sequences to quantify the extent of femoral head involvement. Three pediatric radiologists and one pediatric orthopedic surgeon independently measured central head involvement. Interobserver reliability of percent head involvement using non-contrasted MR images had intraclass correlation coefficient (ICC) of 0.72. Postcontrast MRI improved interobserver reliability (ICC 0.82). Qualitatively, the area of involvement was more clearly visible on contrast-enhanced MRI. A comparison of results obtained by each observer using the two MRI techniques showed no correlation. ICC ranged from -0.08 to 0.03 for each observer. Generally, greater head involvement was depicted by contrast compared with non-contrast MRI (Pearson r = -0.37, P = 0.04). Pre- and postcontrast MRI assess two different components of stage I LCP. However, contrast-enhanced MRI more clearly depicts the area of involvement. (orig.)

  12. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    Science.gov (United States)

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Breast dynamic contrast enhanced MRI: fibrocystic changes presenting as a non-mass enhancement mimicking malignancy

    Directory of Open Access Journals (Sweden)

    Milosevic Zorica C.

    2017-06-01

    Full Text Available We aimed to analyse the morphokinetic features of breast fibrocystic changes (nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia presenting as a non-mass enhancement (NMEin dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI examination.

  14. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    Science.gov (United States)

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  15. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  16. Tuberculosis versus lymphoma in the abdominal lymph nodes: A comparative study using contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Shao, Heng; Yang, Zhi-gang; Deng, Wen; Chen, Jing; Tang, Si-shi; Wen, Ling-yi

    2012-01-01

    Purpose: The purpose of this study was to determine the differential characteristics on MRI between tuberculosis and lymphoma in abdominal lymph nodes. Materials and methods: We conducted a retrospective analysis for the counter, size, signal intensity, enhancement patterns, and anatomic distribution of lymph nodes in 57 consecutive patients with documented tuberculosis (28 patients; 49.1%) and newly diagnosed, untreated lymphoma (29 patients; 50.9%). Results: Twenty-four cases (85.7%) in the tuberculosis group were hyperintense on T2-weighted images and either hypointense or isointense on T1-weighted images with respect to the abdominal wall muscle. All cases in the lymphoma group were hyperintense on T2-weighted images and isointense on T1-weighted images with respect to the abdominal wall muscle. Concerning the main anatomic distribution of lymph nodes, the lymph nodes in the lower paraaortic region were more frequently involved in the lymphoma group (48.3%) than in tuberculosis (17.9%, p < 0.05). Moreover, mesenteric lymph nodes were more often involved in tuberculosis (32.1%) than in lymphoma (6.9%, p < 0.05). Tuberculous lymphadenopathy showed predominantly peripheral enhancement, frequently with a multilocular appearance; whereas lymphomatous adenopathy often demonstrated uniform homogeneous enhancement (all p < 0.001). Conclusion: Contrast-enhanced MRI can be useful in differentiation between these two entities

  17. Utility of re-windowing for MR T2-weighted images in differentiating between benign tumors and cysts

    International Nuclear Information System (INIS)

    Yamamoto, A.; Nishikawa, K.; Otonari-Yamamoto, M.; Sano, T.

    2009-01-01

    Both benign tumors and cysts in the oral and maxillofacial region show clear borders and homogeneously high signal intensity on magnetic resonance (MR T2-weighted images, making differentiation difficult without contrast enhancement. Windowing for brightness and contrast adjustment may be helpful in interpreting relative signal intensities on MR images. This study was performed to determine whether re-windowing against targeted lesions on T2-weighted images was a useful procedure that would enhance differentiation without invasive contrast enhancement. Twenty-six lesions (13 benign tumors, 13 cysts) that showed clear borders and homogeneously high signal intensity on T2-weighted images were examined. The windowing parameters of axial images were readjusted to emphasize contrast only inside the lesions using automatic density adjustment. Re-windowed images were reviewed by three experienced oral radiologists and categorized based on the internal homogeneity of the lesion into four grades: 0, heterogeneous; 1, slightly heterogeneous; 2, slightly homogeneous; 3, homogeneous. Re-windowing was then evaluated for its usefulness in differentiating between benign tumors and cysts. For cysts, the rates of homogeneous (grades 3 and 2) and heterogeneous intensity (grades 1 and 0) were 66.7 (26/39) and 33.3% (13/39), respectively. For benign tumors, these rates were 33.3 (13/39) and 66.7% (26/39), respectively. Cysts showed a higher rate of homogeneous intensity, while the opposite was true for benign tumors. A significant difference in distribution was observed between cysts and benign tumors (P 2 test). Re-windowing for T2-weighted images is helpful in differentiating between benign tumors and cysts with clear borders and homogeneously high signal intensity on T2-weighted images. (author)

  18. Correlative Study of Angiogenesis and Dynamic Contrast-Enhanced Magnetic Resonance Imaging Features of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Wang, B.; Gao, Z.Q.; Yan, X.

    2005-01-01

    Purpose: To explore the correlation between contrast-enhancement patterns on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and angiogenesis by analyzing microvessel density (MVD), vascular endothelial growth factor (VEGF), and P53 protein expression in hepatocellular carcinoma (HCC). Material and Methods: MRI was performed with a GE Signa 5T MR scanner using SE and FMPSPGR sequences in 30 patients (38 lesions) during the period October 1998 to March 2000. All had histopathologically proven HCC. MR images were reviewed/analyzed retrospectively. The 30 patients were between 35 and 65 years of age. SE T1WI, PDWI, and T2WI were acquired initially. The FMPSPGR sequence was acquired in the same position. The DCE-MRI was performed in the arterial, portal vein, and delay phase after a bolus injection of Gd-DTPA. The specimens were stained immunohistochemically for CD34, VEGF, and P53. MVD was highlighted by anti-CD34 antibody staining. The enhancement features of HCC lesions were studied correlatively with the tumor MVD, VEGF, and P53 expression at protein level. Results: In the arterial phase, the results showed that MVD of HCC in the high-enhancement group (229.76±80.96) was higher than that in the equal-enhancement (173.09±61.38) and low-enhancement groups (153.00±108.58) (P <0.01, respectively). VEGF expression of HCC in the high-enhancement group (68.42%) was higher than that in the equal-enhancement (36.36%) and low-enhancement groups (38.89%) (P <0.05, respectively). In the portal vein phase, MVD of HCC in the enhancement group (259.80±93.30) was higher than that in the non-enhancement group (178.64±92.65) (P <0.05). No significant correlation was found between VEGF expression and the enhancement feature in the portal vein phase. In the delay phase, MVD of HCC in the ring-enhancement group (269.06±57.89) was significantly higher than that in the non-ring-enhancement group (144.10±88.90) (P <0.01). There was a significant difference in VEGF

  19. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  20. Diagnostic value of dynamic contrast-enhanced MRI for submucosal palatal tumors

    International Nuclear Information System (INIS)

    Matsuzaki, Hidenobu; Yanagi, Yoshinobu; Hara, Marina; Katase, Naoki; Hisatomi, Miki; Unetsubo, Teruhisa; Konouchi, Hironobu; Takenobu, Toshihiko

    2012-01-01

    Objectives: To evaluate the diagnostic value of dynamic contrast-enhanced MRI (DCE-MRI) for differentiating between benign and malignant tumors in the palate. Materials and methods: 26 patients with submucosal palatal tumors were preoperatively examined using DCE-MRI. Their maximum contrast index (CImax), time of CImax (Tmax), and washout ratios (WR300 and WR600) were determined from contrast index curves. The submucosal palatal tumors were divided into two groups according to their Tmax values: the early enhancement group (Tmax 2 = 0.92, P < 0.001). Conclusions: Tmax is a useful parameter for distinguishing between benign and malignant submucosal palatal tumors.

  1. Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Siemund, Roger; Cronqvist, Mats; Undren, Per; Holtaas, Stig; Nilsson, Ola G.; Larsson, Elna-Marie

    2008-01-01

    The purpose of this prospective study was to compare 3T and 1.5T magnetic resonance angiography (MRA) with digital subtraction angiography (DSA) for the follow-up of endovascular treated intracranial aneurysms to assess the grade of occlusion. Thirty-seven patients with 41 aneurysms who had undergone endovascular treatment with detachable coils were included. MRA was performed on the same day using an eight-channel sensitivity encoding head-coil with 3D axial inflow technique. At 3T, a contrast-enhanced transverse 3D fast gradient echo acquisition was also performed. Most patients underwent DSA the following day. MRA scans and DSA were classified first independently by two neuroradiologists and an interventional neuroradiologist. Secondly, a consensus was done. Source images, maximum intensity projection, multiplanar reconstruction and volume rendering reconstructions were used for MRA evaluations. A modification of the Raymond classification, previously used for DSA evaluation of recanalization, was used. Statistical comparison of the consensus showed that 3T MRA with 3D axial inflow technique had better agreement with DSA (κ = 0.43) than 1.5T MRA(κ = 0.21) and contrast-enhanced MRA (CE-MRA) at 3T (κ = 0.17). The susceptibility artefacts from the coil mesh were significally smaller at 3T (p = 0.002-0.007) than at 1.5T. 3T MRA, using a sensitivity encoding head-coil, showed better agreement with DSA than 1.5T and CE-MRA at 3T for evaluation of aneurysms treated with endovascular coiling. (orig.)

  2. Intravoxel incoehrent motion MR imaging in the head and neck: Correlation with dynamic contrast-enhanced MR imaging and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Beak, Jung Hwan; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Yoon, Ra Gyoung [Dept. of Radiology, Catholic Kwandong University International St. Mary' s Hospital, Catholic Kwandong University College of Medicine, Incheon (Korea, Republic of)

    2016-09-15

    To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D{sup *}), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D{sup *} and model-free parameters from the DCE-MRI (wash-in, T{sub max}, E{sub max}, initial AUC{sub 60}, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D{sup *} and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D{sup *} (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.

  3. Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xiao Quan [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029 (China); Choi, Young Jun; Sung, Yu Sub [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Yoon, Ra Gyoung [Department of Radiology, Catholic Kwandong University International St. Mary' s Hospital, Catholic Kwandong University College of Medicine, Incheon 22711 (Korea, Republic of); Jang, Seung Won; Park, Ji Eun [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Heo, Young Jin [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan 47392 (Korea, Republic of); Baek, Jung Hwan; Lee, Jeong Hyun [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of)

    2016-11-01

    To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D{sup *}), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D{sup *} and model-free parameters from the DCE-MRI (wash-in, T{sub max}, E{sub max}, initial AUC{sub 60}, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D{sup *} and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D{sup *} (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.

  4. Intravoxel incoehrent motion MR imaging in the head and neck: Correlation with dynamic contrast-enhanced MR imaging and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Beak, Jung Hwan; Lee, Jeong Hyun; Yoon, Ra Gyoung

    2016-01-01

    To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D * ), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D * and model-free parameters from the DCE-MRI (wash-in, T max , E max , initial AUC 60 , whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D * and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D * (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck

  5. High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Moser, F G; Watterson, C T; Weiss, S; Austin, M; Mirocha, J; Prasad, R; Wang, J

    2018-02-01

    In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients' first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group ( t = 4.215, P linear gadolinium-based contrast agent group ( t = 2.931, P linear gadolinium-based contrast agents. © 2018 by American Journal of Neuroradiology.

  6. The pseudocapsule in hepatocellular carcinoma: correlation between dynamic MR imaging and pathology

    International Nuclear Information System (INIS)

    Grazioli, L.; Stanga, C.; Dettori, E.; Gallo, C.; Matricardi, L.; Chiesa, A.; Olivetti, L.; Fugazzola, C.; Giacobbe, A.; Benetti, A.

    1999-01-01

    Nodular hepatocellular carcinoma (HCC) is characterized by the presence of a pseudocapsule (constructed usually from connective fibrous tissue) that appears hypointense on T1- and T2-weighted spin-echo (SE) and gradient-echo (GE) MR imaging sequences without a contrast medium. The presence of vascular structures inside the tumor, which are verified by histological exam, affects enhancement of the PC after administrating the contrast medium: The impregnation is more evident in the dynamic study but also persists on the delayed T1-weighted SE images. The accuracy of MR in detecting the pseudocapsule of HCC and contrast enhancement of the pseudocapsule during dynamic studies were evaluated and related to pathological findings. Thirty-seven HCC were examined in 33 patients and afterwards resected. In capsulated nodules, besides usual hematoxylin, eosin, and trichrome stainings, histochemical and immunohistochemical methods were performed. On a 1.5-T MR unit, T1- and T2-weighted SE and GE FLASH 2D sequences after intravenous injection of Gd-DTPA (dynamic study) were used. In a later phase, T1-weighted SE sequences were repeated. Histologically, the pseudocapsule (thickness 0.2-6 mm) was present in 26 of 37 nodules (70 %). The dynamic study was the most suitable technique to show the pseudocapsule, which was recognized in 80.7 % (21 of 26 nodules). In 5 of 26 cases, the pseudocapsule, not demonstrated by MR, was thinner than 0.4 mm. In 16 of 21 cases, in the early portal phase (30-60 s), the pseudocapsule had an early enhancement, which was more evident later; in 5 of 21 cases the enhancement was observed only in the late portal phase (1-2 min). At histological examination, 14 of 16 pseudocapsules with early enhancement showed a more prominent vasculature than those with enhancement in the equilibrium phase. Magnetic resonance was a reliable tool in demonstrating the pseudocapsule of HCC. The histological examination demonstrated a good correlation between the

  7. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  8. Comparison between T2-weighted MR and contrast-enhanced MR cholangiography in the evaluation of biliary anatomy in liver transplant donor candidates

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Wu Chunnan; Dong Yuru; Dong Yue; Zhang Huiqing; Zang Yunjin

    2008-01-01

    Objective: To compare conventional T 2 -weighted MR cholangiography (T 2 WI-MRC) with gadobenate dimeglumine enhanced T 1 -weighted MR cholangiography(CE-MRC) for evalution of biliary anatomy in liver transplant donor candidates. Methods: Thirty-two healthy liver transplant donor candidates were examined with two MR cholangiographic methods. For T 2 WI-MRC, a three-dimensional turbo spin-echo sequence and oblique coronal heavily T 2 -weighted thick-slab turbo spin-echo imaging sequence were performed. For CE-MRC, three-dimensional fat-suppressed spoiled gradient-echo sequences were performed, with a time delay of 60 minutes following the administration of gadobenate dimeglumine. To compare the depiction of biliary duct anatomy and the artifact caused by intestinal liquid and breathing between the two methods. Intraoperative cholangiography was the reference-standard examination. Results: The both methods depicted the biliary anatomy correctly in all 9 cases. The both methods showed the third branches of intrahepatic biliary duct clearly. T 2 WI-MRC showed interhepatic biliary duct before the third branches in 28 cases (87.5%), CE-MRC showed the same finding in 14 eases (43.8%). T 2 WI-MRC showed common bile ducts intermitantly in 2 cases, which were normal in CE-MRC and intraoperative cholangiography. Intestinal liquid affected the image quality of biliary duct in 6 cases (18.8%) performed with T 2 WI-MRC, but none with CE-MRC. The artifacts caused by breathing were not obvious in the either method. Conclusion: T 2 WI-MRC and CE-MRC both can be used to evaluate biliary anatomy of liver transplant donor candidates, but CE-MRC appears to be more accurate than T 2 WI-MRC. (authors)

  9. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  10. Increase in tumour permeability following TGF-? type I receptor-inhibitor treatment observed by dynamic contrast-enhanced MRI

    OpenAIRE

    Minowa, T; Kawano, K; Kuribayashi, H; Shiraishi, K; Sugino, T; Hattori, Y; Yokoyama, M; Maitani, Y

    2009-01-01

    Background: To enhance the success rate of nanocarrier-mediated chemotherapy combined with an anti-angiogenic agent, it is crucial to identify parameters for tumour vasculature that can predict a response to the treatment of the anti-angiogenic agent. Methods: To apply transforming growth factor (TGF)-? type I receptor (T?R-I) inhibitor, A-83-01, to combined therapy, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was carried out in mice bearing colon 26 cells using gadolinium ...

  11. Dynamic contrast enhanced MRI study of primary primitive neuroectodermal tumor in the thoracic spine

    International Nuclear Information System (INIS)

    Chen Yu; Xu Jianmin; Li Ying; Zhang Jingzhong; Zhu Jing

    2004-01-01

    Objective: To investigate the value of dynamic contrast-enhanced MR imaging in the diagnosis and differentiation of primitive neuroectodermal tumor (PNET) in the thoracic spine. Methods: The dynamic contrast-enhanced MR imaging of 2 patients (3 times) with PNET in the thoracic spine proved by surgery and pathology were prospectively studied. Results: In the curves of SI-time and CER-time, PNET in the thoracic spine showed a rapid rise to the peak between 60 s and 120 s, then the flat level was kept and no obvious decline was detected after about 3.5 minute. Conclusion: Dynamic contrast-enhanced MRI can help to make the diagnosis and differential diagnosis for PNET in the thoracic spine, offer reliable information for the choice of clinical management, and predict the prognosis

  12. Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

    International Nuclear Information System (INIS)

    Driscoll, B.; Keller, H.; Coolens, C.

    2011-01-01

    Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments (σ/μ 2 ) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The

  13. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    International Nuclear Information System (INIS)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman; Bay, Ali; Koesem, Mustafa; Dogan, Ekrem

    2005-01-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  14. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    Energy Technology Data Exchange (ETDEWEB)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman [Yuzuncu Yil University Faculty of Medicine, Department of Radiology, Van (Turkey); Bay, Ali [Yuzuncu Yil University Faculty of Medicine, Department of Paediatrics, Van (Turkey); Koesem, Mustafa [Yuzuncu Yil University Faculty of Medicine, Department of Pathology, Van (Turkey); Dogan, Ekrem [Yuzuncu Yil University Faculty of Medicine, Department of Internal Medicine, Van (Turkey)

    2005-05-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  15. Enhancement tuning and control for high dynamic range images in multi-scale locally adaptive contrast enhancement algorithms

    Science.gov (United States)

    Cvetkovic, Sascha D.; Schirris, Johan; de With, Peter H. N.

    2009-01-01

    For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are unacceptable. Compression of the dynamic range is therefore a compulsory part of any high-end video processing chain because standard monitors are inherently Low- Dynamic Range (LDR) devices with maximally two orders of display dynamic range. In real-time camera processing, many complex scenes are improved with local contrast enhancements, bringing details to the best possible visibility. In this paper, we show how a multi-scale high-frequency enhancement scheme, in which gain is a non-linear function of the detail energy, can be used for the dynamic range compression of HDR real-time video camera signals. We also show the connection of our enhancement scheme to the processing way of the Human Visual System (HVS). Our algorithm simultaneously controls perceived sharpness, ringing ("halo") artifacts (contrast) and noise, resulting in a good balance between visibility of details and non-disturbance of artifacts. The overall quality enhancement, suitable for both HDR and LDR scenes, is based on a careful selection of the filter types for the multi-band decomposition and a detailed analysis of the signal per frequency band.

  16. Synergistic enhancement of iron oxide nanoparticle and gadolinium for dual-contrast MRI

    International Nuclear Information System (INIS)

    Zhang, Fan; Huang, Xinglu; Qian, Chunqi; Zhu, Lei; Hida, Naoki; Niu, Gang; Chen, Xiaoyuan

    2012-01-01

    Highlights: ► MR contrast agents exert influence on T 1 or T 2 relaxation time of the surrounding tissue. ► Combined use of iron oxide and Gd-DTPA can improve the sensitivity/specificity of lesion detection. ► Dual contrast MRI enhances the delineation of tumor borders and small lesions. ► The effect of DC-MRI can come from the high paramagnetic susceptibility of Gd 3+ . ► The effect of DC-MRI can also come from the distinct pharmacokinetic distribution of SPIO and Gd-DTPA. -- Abstract: Purpose: The use of MR contrast agents allows accurate diagnosis by exerting an influence on the longitudinal (T 1 ) or transverse (T 2 ) relaxation time of the surrounding tissue. In this study, we combined the use of iron oxide (IO) particles and nonspecific extracellular gadolinium chelate (Gd) in order to further improve the sensitivity and specificity of lesion detection. Procedures: With a 7-Tesla scanner, pre-contrasted, IO-enhanced and dual contrast agent enhanced MRIs were performed in phantom, normal animals, and animal models of lymph node tumor metastases and orthotopic brain tumor. For the dual-contrast (DC) MRI, we focused on the evaluation of T 2 weighted DC MRI with IO administered first, then followed by the injection of a bolus of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Results: Based on the C/N ratios and MRI relaxometry, the synergistic effect of coordinated administration of Gd-DTPA and IO was observed and confirmed in phantom, normal liver and tumor models. At 30 min after administration of Feridex, Gd-DTPA further decreased T 2 relaxation in liver immediately after the injection. Additional administration of Gd-DTPA also immediately increased the signal contrast between tumor and brain parenchyma and maximized the C/N ratio to −4.12 ± 0.71. Dual contrast MRI also enhanced the delineation of tumor borders and small lesions. Conclusions: DC-MRI will be helpful to improve diagnostic accuracy and decrease the threshold size for

  17. A dimensionless dynamic contrast enhanced MRI parameter for intra-prostatic tumour target volume delineation: initial comparison with histology

    Science.gov (United States)

    Hrinivich, W. Thomas; Gibson, Eli; Gaed, Mena; Gomez, Jose A.; Moussa, Madeleine; McKenzie, Charles A.; Bauman, Glenn S.; Ward, Aaron D.; Fenster, Aaron; Wong, Eugene

    2014-03-01

    Purpose: T2 weighted and diffusion weighted magnetic resonance imaging (MRI) show promise in isolating prostate tumours. Dynamic contrast enhanced (DCE)-MRI has also been employed as a component in multi-parametric tumour detection schemes. Model-based parameters such as Ktrans are conventionally used to characterize DCE images and require arterial contrast agent (CR) concentration. A robust parameter map that does not depend on arterial input may be more useful for target volume delineation. We present a dimensionless parameter (Wio) that characterizes CR wash-in and washout rates without requiring arterial CR concentration. Wio is compared to Ktrans in terms of ability to discriminate cancer in the prostate, as demonstrated via comparison with histology. Methods: Three subjects underwent DCE-MRI using gadolinium contrast and 7 s imaging temporal resolution. A pathologist identified cancer on whole-mount histology specimens, and slides were deformably registered to MR images. The ability of Wio maps to discriminate cancer was determined through receiver operating characteristic curve (ROC) analysis. Results: There is a trend that Wio shows greater area under the ROC curve (AUC) than Ktrans with median AUC values of 0.74 and 0.69 respectively, but the difference was not statistically significant based on a Wilcoxon signed-rank test (p = 0.13). Conclusions: Preliminary results indicate that Wio shows potential as a tool for Ktrans QA, showing similar ability to discriminate cancer in the prostate as Ktrans without requiring arterial CR concentration.

  18. Contrast enhanced liver MRI in patients with primary sclerosing cholangitis: inverse appearance of focal confluent fibrosis on delayed phase MR images with hepatocyte specific versus extracellular gadolinium based contrast agents.

    Science.gov (United States)

    Husarik, Daniela B; Gupta, Rajan T; Ringe, Kristina I; Boll, Daniel T; Merkle, Elmar M

    2011-12-01

    To assess the enhancement pattern of focal confluent fibrosis (FCF) on contrast-enhanced hepatic magnetic resonance imaging (MRI) using hepatocyte-specific (Gd-EOB-DTPA) and extracellular (ECA) gadolinium-based contrast agents in patients with primary sclerosing cholangitis (PSC). After institutional review board approval, 10 patients with PSC (6 male, 4 female; 33-61 years) with 13 FCF were included in this retrospective study. All patients had a Gd-EOB-DTPA-enhanced liver MRI exam, and a comparison ECA-enhanced MRI. On each T1-weighted dynamic dataset, the signal intensity (SI) of FCF and the surrounding liver as well as the paraspinal muscle (M) were measured. In the Gd-EOB-DTPA group, hepatocyte phase images were also included. SI FCF/SI M, SI liver/SI M, and [(SI liver - SI FCF)/SI liver] were compared between the different contrast agents for each dynamic phase using the paired Student's t-test. There was no significant difference in SI FCF/SI M in all imaging phases. SI liver/SI M was significantly higher for the Gd-EOB-DTPA group in the delayed phase (P DTPA group, mean [(SI liver - SI FCF)/SI liver] were as follows (values for ECA group in parentheses): unenhanced phase: 0.26 (0.26); arterial phase: 0.01 (-0.31); portal venous phase (PVP): -0.05 (-0.26); delayed phase (DP): 0.14 (-0.54); and hepatocyte phase: 0.26. Differences were significant for the DP (P DTPA-enhanced images. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  19. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    International Nuclear Information System (INIS)

    Kim, Tae Yun; Kim, Sung Hun; Kang, Bong Joo; Kim, Hyeon Sook; Cha, Eun Suk; Kim, Ji Youn; Song, Byung Joo

    2013-01-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  20. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Yun [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, The Catholic University of Korea (Korea, Republic of); Cha, Eun Suk [Department of Radiology, Ewha Womans University, School of Medicine, Mokdong Hospital (Korea, Republic of); Kim, Ji Youn [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Song, Byung Joo [Department of Surgery, Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  1. Quantitative evaluation of the tibial tunnel after anterior cruciate ligament reconstruction using diffusion weighted and dynamic contrast enhanced MRI: a follow-up feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rupreht, Mitja; Seruga, Tomaz; Jevsek, Marko [University Medical Centre Maribor, Radiology Department, Maribor (Slovenia); Jevtic, Vladimir [University of Ljubljana, Medical Faculty, Ljubljana (Slovenia); Sersa, Igor [Jozef Stefan Institute, MRI Laboratory, Ljubljana (Slovenia); Vogrin, Matjaz [University of Medical Centre of Maribor, Department of Orthopaedics, Maribor (Slovenia)

    2012-05-15

    The aim of the study was to evaluate the feasibility of two quantitative MRI methods: diffusion weighted imaging (DWI) and dynamic contrast enhanced imaging (DCEI), for follow-up assessment of the tibial tunnel after reconstruction of the anterior cruciate ligament (ACL). Twenty-three patients were examined by MRI at 1 and 6 months following ACL reconstruction. DWI and DCEI were utilized for evaluating the region of interest (ROI) within the proximal part of the tibial tunnel. From the resulting apparent diffusion coefficient (ADC) maps, ADC values were calculated. DCEI data were used to extract the enhancement factor (f{sub enh}) and the enhancement gradient (g{sub enh}) for the same ROI. Calculated ADC as well as the f{sub enh} and g{sub enh} had diminished to a statistically significant extent by 6 months after ACL reconstruction. The average ADC value diminished from 1.48 (10{sup -3} mm{sup 2}/s) at 1 month to 1.30 (10{sup -3} mm{sup 2}/s) at 6 months after reconstruction. The average f{sub enh} value decreased from 1.21 at 1 month to 0.50 at 6 months and the average g{sub enh} value decreased from 2.01%/s to 1.15%/s at 6 months, respectively. The study proved feasibility of DWI and DCEI for quantitative assessment of the tibial tunnel at 1 and 6 months after ACL reconstruction. Both methods have the potential for use as an additional tool in the evaluation of new methods of ACL reconstruction. To our knowledge, this is the first time quantitative MRI has been used in the follow-up to the ACL graft healing process. (orig.)

  2. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Radlbauer, Rudolf, E-mail: rudolf.radlbauer@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Lomoschitz, Friedrich, E-mail: friedrich.lomoschitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Salomonowitz, Erich, E-mail: erich.salomonowitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Eberhardt, Knut E., E-mail: info@mrt-kompetenzzentrum.d [MRT Competence Center Schloss Werneck, Balthasar-Neumann-Platz 2, 97440 Werneck (Germany); Stadlbauer, Andreas, E-mail: andi@nmr.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen (Germany)

    2010-08-15

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  3. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    International Nuclear Information System (INIS)

    Radlbauer, Rudolf; Lomoschitz, Friedrich; Salomonowitz, Erich; Eberhardt, Knut E.; Stadlbauer, Andreas

    2010-01-01

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  4. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Scheenen, Tom W. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Bathen, Tone F.; Selnaes, Kirsten M. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); St. Olavs Hospital, Trondheim University Hospital, Trondheim (Norway)

    2017-07-15

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K{sup trans} and V{sub e}) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p < 0.05) with both GS and median ADC. Contrast correlated moderately with median ADC. The textural features correlated insignificantly with K{sup trans} and V{sub e}. GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K{sup trans}, and V{sub e}. The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. (orig.)

  5. Intravoxel Incoherent Motion MR Imaging in the Head and Neck: Correlation with Dynamic Contrast-Enhanced MR Imaging and Diffusion-Weighted Imaging.

    Science.gov (United States)

    Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Yoon, Ra Gyoung; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Baek, Jung Hwan; Lee, Jeong Hyun

    2016-01-01

    To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, Tmax, Emax, initial AUC60, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.

  6. The efficacy of fat suppressed and gadolinium enhanced dynamic MR imaging in pancreatic adenocarcinomas

    International Nuclear Information System (INIS)

    Gabata, Toshifumi

    1994-01-01

    The efficacy of both fat suppressed T1-weighted imaging (T1WI) and dynamic gadolinium-enhanced MR imaging (dynamic MRI) was compared with conventional MR sequences and dynamic CT in 22 patients with histologically proven pancreatic adenocarcinoma (PAC). In the control group of 30 patients without pancreatic disease, the pancreas was shown as a markedly higher signal intensity on fat suppressed T1WI than on conventional MR sequences. The signal noise ratio (SNR) of the normal pancreas and the contrast noise ratio (CNR) between the normal pancreas and muscle were significantly higher on fat suppressed T1WI than the other MR sequences. In the group of PAC patients without chronic pancreatitis (n=14), CNR between the tumor and the normal pancreas significantly differed among imaging techniques, including fat suppressed T1WI, dynamic MRI, and the other conventional MR sequences. In the group of PAC with chronic pancreatitis (n=8), CNR between the tumor and the associated chronic pancreatitis was remarkably diminished on both fat suppressed T1WI and conventional T1WI; however, it was significantly higher on dynamic MRI than the other pulse sequences. The early phase of dynamic MRI clearly identified the tumors in the group of PAC. The capability of conventional T1WI and dynamic CT to demonstrate peripancreatic tumor extension was significantly higher than that of fat suppressed T1WI. In conclusion, fat suppressed T1WI and dynamic MRI were useful in detecting pancreatic carcinoma. (N.K.)

  7. Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging.

    Directory of Open Access Journals (Sweden)

    Shailesh B Raval

    Full Text Available The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity].A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization].High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The

  8. Quantifying heterogeneity of lesion uptake in dynamic contrast enhanced MRI for breast cancer diagnosis

    International Nuclear Information System (INIS)

    Karahaliou, A; Skiadopoulos, S; Yiakoumelos, A; Costaridou, L; Vassiou, K; Kanavou, T

    2009-01-01

    The current study investigates whether texture features extracted from lesion kinetics feature maps can be used for breast cancer diagnosis. Fifty five women with 57 breast lesions (27 benign, 30 malignant) were subjected to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on 1.5T system. A linear-slope model was fitted pixel-wise to a representative lesion slice time series and fitted parameters were used to create three kinetic maps (wash out, time to peak enhancement and peak enhancement). 28 grey level co-occurrence matrices features were extracted from each lesion kinetic map. The ability of texture features per map in discriminating malignant from benign lesions was investigated using a Probabilistic Neural Network classifier. Additional classification was performed by combining classification outputs of most discriminating feature subsets from the three maps, via majority voting. The combined scheme outperformed classification based on individual maps achieving area under Receiver Operating Characteristics curve 0.960±0.029. Results suggest that heterogeneity of breast lesion kinetics, as quantified by texture analysis, may contribute to computer assisted tissue characterization in DCE-MRI.

  9. Differentiating between Central Nervous System Lymphoma and High-grade Glioma Using Dynamic Susceptibility Contrast and Dynamic Contrast-enhanced MR Imaging with Histogram Analysis.

    Science.gov (United States)

    Murayama, Kazuhiro; Nishiyama, Yuya; Hirose, Yuichi; Abe, Masato; Ohyu, Shigeharu; Ninomiya, Ayako; Fukuba, Takashi; Katada, Kazuhiro; Toyama, Hiroshi

    2018-01-10

    We evaluated the diagnostic performance of histogram analysis of data from a combination of dynamic susceptibility contrast (DSC)-MRI and dynamic contrast-enhanced (DCE)-MRI for quantitative differentiation between central nervous system lymphoma (CNSL) and high-grade glioma (HGG), with the aim of identifying useful perfusion parameters as objective radiological markers for differentiating between them. Eight lesions with CNSLs and 15 with HGGs who underwent MRI examination, including DCE and DSC-MRI, were enrolled in our retrospective study. DSC-MRI provides a corrected cerebral blood volume (cCBV), and DCE-MRI provides a volume transfer coefficient (K trans ) for transfer from plasma to the extravascular extracellular space. K trans and cCBV were measured from a round region-of-interest in the slice of maximum size on the contrast-enhanced lesion. The differences in t values between CNSL and HGG for determining the most appropriate percentile of K trans and cCBV were investigated. The differences in K trans , cCBV, and K trans /cCBV between CNSL and HGG were investigated using histogram analysis. Receiver operating characteristic (ROC) analysis of K trans , cCBV, and K trans /cCBV ratio was performed. The 30 th percentile (C30) in K trans and 80 th percentile (C80) in cCBV were the most appropriate percentiles for distinguishing between CNSL and HGG from the differences in t values. CNSL showed significantly lower C80 cCBV, significantly higher C30 K trans , and significantly higher C30 K trans /C80 cCBV than those of HGG. In ROC analysis, C30 K trans /C80 cCBV had the best discriminative value for differentiating between CNSL and HGG as compared to C30 K trans or C80 cCBV. The combination of K trans by DCE-MRI and cCBV by DSC-MRI was found to reveal the characteristics of vascularity and permeability of a lesion more precisely than either K trans or cCBV alone. Histogram analysis of these vascular microenvironments enabled quantitative differentiation between

  10. Is a dynamic MRI examination of the pancreas still necessary?

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, N.; Willinek, W.A.; Falkenhausen, M. von; Flacke, S.; Schild, H.; Kreft, B.

    2002-01-01

    Purpose: Evaluation of the diagnostic potential of a dynamic MR examination of the pancreas. Material and Methods: Retrospective study on 49 patients who underwent MRI of the pancreas (2 insulinomas, 2 cystadenomas, 19 pancreatic carcinomas, 26 patients with chronic pancreatitis). Interpretation was done in two steps: Initial evaluation of T 2 -weighted TSE-sequences, T 1 -weighted gradient echo sequences before and after injection of Gadolinium-DTPA i.v. Afterwards, additional evaluation of a dynamic contrast-enhanced MRI series of the pancreas with four dynamic scans. Result: Dynamic MR examination of the pancreas is useful in case of insulinomas. However, in case of pancreatic cancer an additional dynamic MR examination of the pancreas does not provide further clinically relevant information. Conclusion: In patients with a suspicion of pancreatic cancer, the injection of contrast material should preferably be used for the performance of a contrast-enhanced MR angiography at the expense of a dynamic MR examination. (orig.) [de

  11. MR findings of medulloblastomas and the significance of contrast enhanced MR of brain and spine for the staging

    International Nuclear Information System (INIS)

    Chung, Jae Joon; Kim, Dong Ik; Chung, Tae Sub; Lee, Yeon Hee; Suh, Jung Ho

    1994-01-01

    The purpose of this study were to analyze the MR findings of medulloblastoma, and to evaluate the subarachnoid dissemination and the significance of contrast enhanced MR of brain and spine for tumor staging. The preoperative brain MR studies of 18 patients (9 males, 9 females; mean age, 9.4 years) with surgically proved medulloblastomas were retrospectively reviewed to characterize these neoplasms with regard to their location, size, MR signal intensity, appearance after contrast enhancement, presence of cyst and necrosis, subarachnoid dissemination, and other associated findings. In 14 patients postoperative spine MR studies were evaluated for staging and therapeutic planning. The most frequent location of medulloblastoma was the inferior vermis and the mean tumor size was 4.1 x 3.6 x 3.9 cm. On T1-weighted image, medulloblastomas generally had low to intermediate signal, predominantly hypointense relative to white matter. On T2-weighted image, medulloblastomas showed moderately high signal, hyperintense relative to white matter. Inhomogeneous contrast enhancement was demonstrated in 13 patients(72.2%) after injection of gadopentetate dimeglumine(Gadolinium). Cyst and necrosis within the tumor were visualized in 15 patients(83.3%). Subarachnoid disseminations of medulloblastomas were noted in 11 patients(61.1%), of which 6 demonstrated intracranial and 2 intraspinal dissemination. Three had both intracranial and intraspinal dissemination. In nine cases with intracranial lesions, there were intraparenchymal mass formation(7), subarachnoid nodules(5), infundibular lesions(2) and diffuse gyral enhancement(1). In five cases with intraspinal lesions, there were extramedullary intradural small nodules(3), central canal nodules(2), intradural masses(1) and fine nodular and sheet-like leptomeningeal enhancement(1). Other associated findings included intratumoral hemorrhage(11.1%), peritumoral edema(44.4%), tonsillar herniation(44.4%), hydrocephalus(88.9%) and

  12. Gd-DTPA as a paramagnetic contrast agent in MR imaging of focal liver lesions

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Wolf, K.J.; Felix, R.; Weinmann, H.J.

    1986-01-01

    Gd-DTPA enhances signal intensity in healthy liver and in intrahepatic tumors. However, after contrast agent administration, tumor enhances significantly more than liver parenchyma (2α≤ 0.05). Doubling the dose of Gd-DTPA from 0.1 to 0.2 mmol/kg of body weight increases the enhancement of intrahepatic tumors (2α≤ 0.05) and optimizes the contrast between tumor and liver in T1-weighted spin-echo sequences. However, the contrast between tumor and liver on inversion-recovery and T2-weighted images obtained before contrast agent administration is much greater than the difference on T1-weighted images obtained after contrast agent administration (2α≤ 0.05). In fast images the contrast between liver and tumor can be markedly improved by administering Gd-DTPA

  13. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    Science.gov (United States)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg-1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  14. Contrast-enhanced MR imaging of the endolymphatic sac in patients with sudden hearing loss

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Ishigaki, Takeo; Nakashima, Tsutomu; Ichinose, Nobuyasu

    2002-01-01

    Our objective was to evaluate the frequency of contrast enhancement of the endolymphatic sac in patients with sudden hearing loss. Forty consecutive patients with sudden sensorineural hearing loss (20 males and 20 females; age range 11-82 years), 40 age-matched control subjects, and 5 patients with Meniere's disease were examined using the same imaging protocol on a 1.5-T MR system. Pre- and post-contrast-enhanced T1-weighted 3D spoiled gradient-echo sequence (3D SPGR; TR/TE=23/10 ms, no. of excitations=1, flip angle=30 ) images were obtained using a voxel size of 0.6 x 0.7 x 0.8 mm 3 . Contrast enhancement in the area of the endolymphatic sac was assessed by two radiologists, and the frequency of contrast enhancement was compared between the three study groups. Enhancement of the ipsilateral endolymphatic sac was observed in 30 of the 40 patients with sudden hearing loss (75%). Twenty of these 30 patients also showed enhancement on the contralateral side, and 1 patient showed enhancement only on the contralateral side. Only 1 of the 5 patients with Meniere's disease showed enhancement. Nine of the 40 control subjects (22.5%) showed enhancement (bilateral enhancement in 5 subjects, unilateral in 4). The frequency of enhancement in patients with sudden hearing loss was significantly higher than that in control subjects (P<0.0001) or patients with Meniere's disease (P<0.05). The frequency of contrast enhancement of the endolymphatic sac is significantly increased in patients with sudden hearing loss, but further study is necessary to clarify the relationship between this finding and the pathophysiology of sudden hearing loss. (orig.)

  15. Topical contrast-enhanced magnetic resonance dacryocystography

    International Nuclear Information System (INIS)

    Yoshikawa, Takeshi; Sugimura, Kazuro; Hirota, Shozo

    2000-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance dacryocystography (MRD) with topical administration of normal saline solution and diluted Gd-DTPA solution for the assessment of lacrimal outflow disorders. Two T2-weighted sequences and two T1-weighted sequences were evaluated in this study. The 1:100 diluted Gd solution was prepared by diluting Gd-DTPA (Magnevist) with normal saline solution. A phantom study using tube phantoms of various diameters filled with normal saline solution and 1:100 diluted Gd solution was performed. A preliminary study was performed in ten normal volunteers Eighteen patients with lacrimal outflow disorders underwent clinical MRD, and 14 also underwent conventional dacryocystography (CDG). MRD images were evaluated and compared with clinical symptoms and CDG images. In all sequences, MRD could visualize the full length of 0.7 to 1.7 mm diameter tube phantoms and could show all of the normal lacrimal sacs and nasolacrimal ducts. In the clinical study, MRD findings were compatible with the symptoms in 14 patients but were not compatible with CDG findings in half of the cases. Topical contrast-enhanced MRD provided a simple, non-invasive means of obtaining detailed morphological and functional information on the lacrimal drainage apparatus. (author)

  16. Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Hori, Masatoshi; Kim, Tonsok; Onishi, Hiromitsu; Nakamoto, Atsushi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imaoka, Izumi; Kagawa, Yuki; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osaka (Japan); Ueguchi, Takashi; Tatsumi, Mitsuaki [Osaka University Hospital, Department of Radiology, Osaka (Japan); Enomoto, Takayuki [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan); Niigata University School of Medicine, Department of Obstetrics and Gynecology, Niigata (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan)

    2013-08-15

    To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm{sup 2}) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW - observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE - observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. (orig.)

  17. Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.

    Science.gov (United States)

    Jiang, Kai; Tang, Hui; Mishra, Prasanna K; Macura, Slobodan I; Lerman, Lilach O

    2018-06-01

    To develop and validate a method for measuring murine single-kidney glomerular filtration rate (GFR) using dynamic contrast-enhanced MRI (DCE-MRI). This prospective study was approved by the Institutional Animal Care and Use Committee. A fast longitudinal relaxation time (T 1 ) measurement method was implemented to capture gadolinium dynamics (1 s/scan), and a modified two-compartment model was developed to quantify GFR as well as renal perfusion using 16.4T MRI in mice 2 weeks after unilateral renal artery stenosis (RAS, n = 6) or sham (n = 8) surgeries. This approach was validated by comparing model-derived GFR and perfusion to those obtained by fluorescein isothiocyanante (FITC)-inulin clearance and arterial spin labeling (ASL), respectively, using the Pearson's and Spearman's rank correlations and Bland-Altman analysis. The compartmental model provided a good fitting to measured gadolinium dynamics in both normal and RAS kidneys. The proposed DCE-MRI method offered assessment of single-kidney GFR and perfusion, comparable to the FITC-inulin clearance (Pearson's correlation coefficient r = 0.95 and Spearman's correlation coefficient ρ = 0.94, P < 0.0001, and mean difference -7.0 ± 11.0 μL/min) and ASL (r = 0.92 and ρ = 0.84, P < 0.0001, and mean difference 4.4 ± 66.1 mL/100 g/min) methods. The proposed DCE-MRI method may be useful for reliable noninvasive measurements of single-kidney GFR and perfusion in mice. Magn Reson Med 79:2935-2943, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia?

    International Nuclear Information System (INIS)

    Baudelet, Christine; Ansiaux, Reginald; Jordan, Benedicte F; Havaux, Xavier; Macq, Benoit; Gallez, Bernard

    2004-01-01

    T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions

  19. Dynamics of contrast enhancement in MR imaging and power Doppler ultrasonography of solid breast lesions

    International Nuclear Information System (INIS)

    Reinikainen, H.; Paeaekkoe, E.; Suramo, I.; Paeivaensalo, M.; Rissanen, T.

    2002-01-01

    Purpose: To evaluate the dynamics of contrast enhancement in solid breast lesions at contrast-enhanced MR imaging and power Doppler ultrasonography (US) and to compare the methods to histology and to each other. Material and Methods: Forty breast lesions were prospectively examined with dynamic MR and power Doppler US. Time-signal intensity curves of enhancement were obtained for both methods. The shape of the curve was analyzed to be benign, indeterminate or malignant. The curves were also analyzed quantitatively by calculating the slope of the curve and the area under the curve (both methods), relative enhancement (MR), and time to peak (US). The lesions were divided into malignant lesions, fibroadenomas, and other benign lesions. The results were compared to histology. Results: In the subjective analysis of the MR curve in differentiating between benign and malignant lesions the accuracy was 90%. The MR curve also enabled differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between malignancies and fibroadenomas. Using the US variables, no significant difference was found between the groups. Conclusion: The dynamics of contrast-enhanced MR were reliable in the differential diagnosis of solid breast lesions, but contrast-enhanced power Doppler US was of limited value

  20. Contrast between hypervascularized liver lesions and hepatic parenchyma. Early dynamic PET versus contrast-enhanced CT

    International Nuclear Information System (INIS)

    Freesmeyer, M.; Winkens, T.; Schierz, J.-H.

    2014-01-01

    To detect hypervascularized liver lesions, early dynamic (ED) 18 F-FDG PET may be an alternative when contrast-enhanced (CE) imaging is infeasible. This retrospective pilot analysis compared contrast between such lesions and liver parenchyma, an important objective image quality variable, in ED PET versus CE CT. Twenty-eight hypervascularized liver lesions detected by CE CT [21 (75%) hepatocellular carcinomas; mean (range) diameter 4.9 ± 3.5 (1-14) cm] in 20 patients were scanned with ED PET. Using regions of interest, maximum and mean lesional and parenchymal signals at baseline, arterial and venous phases were calculated for ED PET and CE CT. Lesional/parenchymal signal ratio was significantly higher (P < 0.005) with ED PET versus CE CT at the arterial phase and similar between the methods at the venous phase. In liver imaging, ED PET generates greater lesional-parenchymal contrast during the arterial phase than does CE CT; these observations should be formally, prospectively evaluated. (author)

  1. Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideki; Seiji, Kazumasa; Kawabata, Masahiro; Satani, Nozomi; Matsuura, Tomonori; Tominaga, Junya; Takase, Kei [Tohoku University Hospital, Department of Diagnostic Radiology, Sendai (Japan); Omata, Kei; Ono, Yoshikiyo; Iwakura, Yoshitsugu; Morimoto, Ryo; Kudo, Masataka; Satoh, Fumitoshi; Ito, Sadayoshi [Tohoku University Hospital, Division of Nephrology, Endocrinology and Vascular Medicine, Sendai (Japan)

    2016-03-15

    To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. The RAV was visualized in 93.2 % by CT and 84.8 % by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100 % for CT and 95.2 % for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16 % of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70 % of subjects. Success rate of AVS was 99.2 %. Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. (orig.)

  2. Quantitative susceptibility mapping across two clinical field strengths: Contrast-to-noise ratio enhancement at 1.5T.

    Science.gov (United States)

    Ippoliti, Matteo; Adams, Lisa C; Winfried, Brenner; Hamm, Bernd; Spincemaille, Pascal; Wang, Yi; Makowski, Marcus R

    2018-04-16

    Quantitative susceptibility mapping (QSM) is an MRI postprocessing technique that allows quantification of the spatial distribution of tissue magnetic susceptibility in vivo. Contributing sources include iron, blood products, calcium, myelin, and lipid content. To evaluate the reproducibility and consistency of QSM across clinical field strengths of 1.5T and 3T and to optimize the contrast-to-noise ratio (CNR) at 1.5T through bandwidth tuning. Prospective. Sixteen healthy volunteers (10 men, 6 women; age range 24-37; mean age 27.8 ± 3.2 years). 1.5T and 3T systems from the same vendor. Four spoiled gradient echo (SPGR) sequences were designed with different acquisition bandwidths. QSM reconstruction was achieved through a nonlinear morphology-enabled dipole inversion (MEDI) algorithm employing L1 regularization. CNR was calculated in seven regions of interest (ROIs), while reproducibility and consistency of QSM measurements were evaluated through voxel-based and region-specific linear correlation analyses and Bland-Altman plots. Interclass correlation, Wilcoxon rank sum test, linear regression analysis, Bland-Altman analysis, Welch's t-test. CNR analysis showed a statistically significant (P limits of agreement from -18.7 to 25.8 ppb) in the ROI-based analysis, while the correlation was found to be good for the voxel-based analysis of averaged maps (R ≥ 0.90, widest limits of agreement from -9.3 to 9.1 ppb). CNR of QSM images reconstructed from 1.5T acquisitions can be enhanced through bandwidth tuning. MEDI-based QSM reconstruction demonstrated to be reproducible and consistent both across field strengths (1.5T and 3T) and bandwidth variation. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  3. Contrast-enhanced MRI of intrasellar arachnoid cysts: relationship between the pituitary gland and cyst

    International Nuclear Information System (INIS)

    Nomura, M.; Kanazawa Univ. School of Medicine; Tachibana, O.; Hasegawa, M.; Kohda, Y.; Nakada, M.; Yamashima, T.; Yamashita, J.; Suzuki, M.

    1996-01-01

    We recently encountered two large intrasellar arachnoid cysts extending to the suprasellar region. The intensity of the cyst contents was identical to that of the cerebrospinal fluid on both T1- and T2-weighted MRI. On contrast-enhanced MRI, the pituitary gland was compressed posteroinferiorly and flattened in the sella turcica. In this report of rare intrasellar arachnoid cysts the discussion is focused on dislocation of the pituitary gland. (orig.)

  4. Statistical clustering of parametric maps from dynamic contrast enhanced MRI and an associated decision tree model for non-invasive tumour grading of T1b solid clear cell renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Xi, Yin; Yuan, Qing; Zhang, Yue; Fulkerson, Michael [UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Madhuranthakam, Ananth J. [UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); UT Southwestern Medical Center, Advanced Imaging Research Center, Dallas, TX (United States); Margulis, Vitaly; Cadeddu, Jeffrey A. [UT Southwestern Medical Center, Department of Urology, Dallas, TX (United States); UT Southwestern Medical Center, Kidney Cancer Program, Simmons Comprehensive Cancer Center, Dallas, TX (United States); Brugarolas, James [UT Southwestern Medical Center, Kidney Cancer Program, Simmons Comprehensive Cancer Center, Dallas, TX (United States); UT Southwestern Medical Center, Department of Internal Medicine, Dallas, TX (United States); Kapur, Payal [UT Southwestern Medical Center, Department of Urology, Dallas, TX (United States); UT Southwestern Medical Center, Kidney Cancer Program, Simmons Comprehensive Cancer Center, Dallas, TX (United States); UT Southwestern Medical Center, Department of Pathology, Dallas, Texas (United States); Pedrosa, Ivan [UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); UT Southwestern Medical Center, Advanced Imaging Research Center, Dallas, TX (United States); UT Southwestern Medical Center, Kidney Cancer Program, Simmons Comprehensive Cancer Center, Dallas, TX (United States)

    2018-01-15

    To apply a statistical clustering algorithm to combine information from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) into a single tumour map to distinguish high-grade from low-grade T1b clear cell renal cell carcinoma (ccRCC). This prospective, Institutional Review Board -approved, Health Insurance Portability and Accountability Act -compliant study included 18 patients with solid T1b ccRCC who underwent pre-surgical DCE MRI. After statistical clustering of the parametric maps of the transfer constant between the intravascular and extravascular space (K{sup trans}), rate constant (K{sub ep}) and initial area under the concentration curve (iAUC) with a fuzzy c-means (FCM) algorithm, each tumour was segmented into three regions (low/medium/high active areas). Percentages of each region and tumour size were compared to tumour grade at histopathology. A decision-tree model was constructed to select the best parameter(s) to predict high-grade ccRCC. Seven high-grade and 11 low-grade T1b ccRCCs were included. High-grade histology was associated with higher percent high active areas (p = 0.0154) and this was the only feature selected by the decision tree model, which had a diagnostic performance of 78% accuracy, 86% sensitivity, 73% specificity, 67% positive predictive value and 89% negative predictive value. The FCM integrates multiple DCE-derived parameter maps and identifies tumour regions with unique pharmacokinetic characteristics. Using this approach, a decision tree model using criteria beyond size to predict tumour grade in T1b ccRCCs is proposed. (orig.)

  5. Statistical clustering of parametric maps from dynamic contrast enhanced MRI and an associated decision tree model for non-invasive tumour grading of T1b solid clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Xi, Yin; Yuan, Qing; Zhang, Yue; Fulkerson, Michael; Madhuranthakam, Ananth J.; Margulis, Vitaly; Cadeddu, Jeffrey A.; Brugarolas, James; Kapur, Payal; Pedrosa, Ivan

    2018-01-01

    To apply a statistical clustering algorithm to combine information from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) into a single tumour map to distinguish high-grade from low-grade T1b clear cell renal cell carcinoma (ccRCC). This prospective, Institutional Review Board -approved, Health Insurance Portability and Accountability Act -compliant study included 18 patients with solid T1b ccRCC who underwent pre-surgical DCE MRI. After statistical clustering of the parametric maps of the transfer constant between the intravascular and extravascular space (K trans ), rate constant (K ep ) and initial area under the concentration curve (iAUC) with a fuzzy c-means (FCM) algorithm, each tumour was segmented into three regions (low/medium/high active areas). Percentages of each region and tumour size were compared to tumour grade at histopathology. A decision-tree model was constructed to select the best parameter(s) to predict high-grade ccRCC. Seven high-grade and 11 low-grade T1b ccRCCs were included. High-grade histology was associated with higher percent high active areas (p = 0.0154) and this was the only feature selected by the decision tree model, which had a diagnostic performance of 78% accuracy, 86% sensitivity, 73% specificity, 67% positive predictive value and 89% negative predictive value. The FCM integrates multiple DCE-derived parameter maps and identifies tumour regions with unique pharmacokinetic characteristics. Using this approach, a decision tree model using criteria beyond size to predict tumour grade in T1b ccRCCs is proposed. (orig.)

  6. Evaluation of iron colloid-enhanced T{sub 2}-weighted fast MR imaging of hepatocellular carcinoma. Comparison of SE, TSE and TGSE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Shuji; Suto, Yuji; Kamba, Masayuki; Yoshida, Kotarou; Ohta, Yoshio [Tottori Univ., Yonago (Japan). Faculty of Medicine

    1996-06-01

    We have applied chondroitin sulfate iron colloid (CSIC) as a contrast agent for MRI in detecting hepatocellular carcinoma (HCC) on conventional spin-echo sequences (SE). In this report, we evaluated CSIC-enhanced T{sub 2}-weighted fast MR imaging of HCC. MR imaging were performed before and after i.v. administration of CSIC in 15 patients with 46 HCCs. T{sub 2}-weighted SE (1800/80/2, 210 x 256 matrix), T{sub 2}-weighted turbo spin-echo (TSE1800) (1800/90/5, echo train length=7, 252 x 256 matrix), TSE (3500/90/5, echo train length=7, 252 x 256 matrix) (TSE7), TSE (3500/99/5, echo train length=11, 242 x 256 matrix) (TSE11) and T{sub 2}-weighted turbo-gradient spine-echo (TGSE) (4500/108/4, echo train length=33, 252 x 256 matrix) images were compared quantitatively and qualitatively. In all sequences, liver signal-to-noise ratio (SNR) was significantly decreased and lesion-to-liver contrast-to-noise ratio (CNR) was significantly increased after CSIC administration. Although decreased ratio in liver and tumor SNR caused by CSIC was smaller on TSE sequences compared with SE and TGSE, increased ratio in lesion-to-liver CNR was largest on TSE7. Either before or after i.v. administration of CSIC, the number of detectable lesions was largest on TSE7. TSE with used longer TR, TE and decreased echo factor was useful method for CSIC-enhanced abdominal MR imaging. (author)

  7. Comparison of positive and negative enteral contrast agents for MR imaging of the abdomen

    International Nuclear Information System (INIS)

    Kaminsky, S.; Langer, M.

    1994-01-01

    Following oral administration of a buffered gadopentetate-dimeglumine solution (Magnevist enteral R , 1 mmol/l, 6-17 ml/kg) T 1 -, proton-density- and T 2 -weighted spin-echo images of abdominal and retroperitoneal lesions were acquired (0.5 T). Gadopentetate is a signal-enhancing, positive MR contrast agent, intraluminar air served as a model of a signal-free, negative agent. In 21 patients contrast/noise ratios of gadopentetate and air versus lesions and fat were compared quantitatively (t-test). In T 1 - and T 2 -weighted images contrast/noise ratios of gadopentetate versus lesions were significantly higher than those of air. In proton-density images there was no significant difference. In T 1 - and proton-density images contrast/noise ratios of air versus abdominal fat were significantly higher than those of gadopentetate, in T 2 -weighted images gadopentetate had a significantly higher contrast/noise ratio than air. Signal-enhancing positive contrast agents seem advantageous over signal-free negative enteral MR contrast agents. (orig.) [de

  8. Optimal gadolinium dose level for magnetic resonance imaging (MRI) contrast enhancement of U87-derived tumors in athymic nude rats for the assessment of photodynamic therapy

    Science.gov (United States)

    Cross, Nathan; Varghai, Davood; Flask, Chris A.; Feyes, Denise K.; Oleinick, Nancy L.; Dean, David

    2009-02-01

    This study aims to determine the effect of varying gadopentetate dimeglumine (Gd-DTPA) dose on Dynamic Contrast Enhanced-Magnetic Resonance Imaging (DCE-MRI) tracking of brain tumor photodynamic therapy (PDT) outcome. Methods: We injected 2.5 x 105 U87 cells (derived from human malignant glioma) into the brains of six athymic nude rats. After 9, 12, and 13 days DCE-MRI images were acquired on a 9.4 T micro-MRI scanner before and after administration of 100, 150, or 200 μL of Gd-DTPA. Results: Tumor region normalized DCE-MRI scan enhancement at peak was: 1.217 over baseline (0.018 Standard Error [SE]) at the 100 μL dose, 1.339 (0.013 SE) at the 150 μL dose, and 1.287 (0.014 SE) at the 200 μL dose. DCE-MRI peak tumor enhancement at the 150 μL dose was significantly greater than both the 100 μL dose (p DTPA dose provided the greatest T1 weighted contrast enhancement, while minimizing negative T2* effects, in DCE-MRI scans of U87-derived tumors. Maximizing Gd-DTPA enhancement in DCE-MRI scans may assist development of a clinically robust (i.e., unambiguous) technique for PDT outcome assessment.

  9. A thickened or indistinct junctional zone on T2-weighted MR images in patients with endometrial carcinoma: pathologic consideration based on microcirculation

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Yumiko Oishi; Saida, Yukihisa; Itai, Yuji [Department of Radiology, Institute of Clinical Medicine' ' University of Tsukuba, 1-1-1 Tennodai, Tsukuba, 305-8575, Ibaraki (Japan); Nishida, Masato; Tsunoda, Hajime; Ichikawa, Yoshihito [Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, 305-8575, Ibaraki (Japan)

    2003-08-01

    Thickened or indistinct junctional zone (JZ) is a problematic finding in staging endometrial carcinoma. We studied the incidence, pathological cause of this condition correlated to microcirculation, and the utility of dynamic contrast MRI for differential diagnosis. T2-weighted images were analyzed in 119 cases with endometrial carcinoma. The enhancement of the JZ during the dynamic contrast MRI, histopathological causes, and the density of arterioles in the JZ were retrospectively analyzed in cases with thickened or indistinct JZ. The MRI histopathological correlation of all 31 patients with a thickened or indistinct JZ were analyzed, in which it was corresponded to myometrial cancer invasion only in 22%. The sensitivity of a poor early enhancement pattern on dynamic study for detecting myometrial invasion was 71.4%, the specificity was 100%, and the overall accuracy was 92.5%. Although only weak relationship between the contrast enhancement and the arteriole density was revealed, the arteriole density within the JZ with cancer invasion was significantly decreased. Poor enhancement of JZ in early dynamic phase was correlated with the decreased density of arterioles within the myometrium which was invaded by endometrial carcinoma. Dynamic contrast study should be performed in staging endometrial carcinoma especially when JZ was thickened or indistinct. (orig.)

  10. A Combined Pharmacokinetic and Radiologic Assessment of Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Response to Chemoradiation in Locally Advanced Cervical Cancer

    International Nuclear Information System (INIS)

    Semple, Scott; Harry, Vanessa N. MRCOG.; Parkin, David E.; Gilbert, Fiona J.

    2009-01-01

    Purpose: To investigate the combination of pharmacokinetic and radiologic assessment of dynamic contrast-enhanced magnetic resonance imaging (MRI) as an early response indicator in women receiving chemoradiation for advanced cervical cancer. Methods and Materials: Twenty women with locally advanced cervical cancer were included in a prospective cohort study. Dynamic contrast-enhanced MRI was carried out before chemoradiation, after 2 weeks of therapy, and at the conclusion of therapy using a 1.5-T MRI scanner. Radiologic assessment of uptake parameters was obtained from resultant intensity curves. Pharmacokinetic analysis using a multicompartment model was also performed. General linear modeling was used to combine radiologic and pharmacokinetic parameters and correlated with eventual response as determined by change in MRI tumor size and conventional clinical response. A subgroup of 11 women underwent repeat pretherapy MRI to test pharmacokinetic reproducibility. Results: Pretherapy radiologic parameters and pharmacokinetic K trans correlated with response (p < 0.01). General linear modeling demonstrated that a combination of radiologic and pharmacokinetic assessments before therapy was able to predict more than 88% of variance of response. Reproducibility of pharmacokinetic modeling was confirmed. Conclusions: A combination of radiologic assessment with pharmacokinetic modeling applied to dynamic MRI before the start of chemoradiation improves the predictive power of either by more than 20%. The potential improvements in therapy response prediction using this type of combined analysis of dynamic contrast-enhanced MRI may aid in the development of more individualized, effective therapy regimens for this patient group.

  11. Comparative study of diffusion weighted imaging and dynamic contrast enhanced MRI for the detection of small breast cancers

    International Nuclear Information System (INIS)

    Tang Jianhua; Yan Fuhua; Zhou Meiling; Ye Fang; Xu Pengju

    2008-01-01

    Objective: To compare the sensitivity of diffusion weighted imaging (DWI) with dynamic contrast enhanced (DCE) MRI for the detection of small breast cancers and to evaluate the clinical value of DWI. Methods: Forty-eight patients with benign (n=25) and malignant (n=45) small breast lesions (≤2 cm) proved by pathology underwent DWI and DCE MRI. The DCE MRI was performed using FLASH sequence and the time-signal intensity curve was drawn. The DWI was performed using GRAPPA- EPI sequence with different b values (800, 1000 s/mm 2 ) and the ADC values of lesions were measured. The sensitivity and specificity of DWI for the detection of small breast cancers were compared with DCE MRI. Results: Forty of 45 small breast cancers and 19 of 25 small benign breast lesions were correctly diagnosed using DCE MRI. The sensitivity and positive predictive value of TIC were 88.9% (40/45) and 87.0% (40/46). With b values of 800 s/mm 2 and 1000 s/mm 2 , the average ADC values of small breast cancers were (1.153±0.192) x 10 -3 and (1.079±0.186) x 10 -3 mm 2 /s, while those of benign ones were (1.473±0.252) x 10 -3 and (1.419 ± 0.255) x 10 -3 mm 2 /s, respectively. There was no significant difference for the ADC values with different b values in the same group (P>0.05), while there was a significant difference between the malignant and the benign lesions (P 2 . Both the sensitivity and positive predictive value of diagnosis were 86.7% (39/45). The abilities of DWI and DCE MRI for the diagnosis of small breast cancers were the same. The sensitivity (93.3%) and positive predictive value (91.3%) were improved with the combination of DCE MRI and DWI. Conclusion: DWI has a high sensitivity for the detection of small breast cancers, the ADC value can provide valuable information in the differential diagnosis. (authors)

  12. Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

    OpenAIRE

    Assili, S.; Fathi Kazerooni, A.; Aghaghazvini, L.; Saligheh Rad, H.R.; Pirayesh Islamian, J.

    2015-01-01

    Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional MRI techniques, namely dynamic contrast enhanced (DCE-) MRI and diffusion-weighted ...

  13. Dynamic MR imaging of liver lesions with superparamagnetic iron oxide (SH-U-555A)

    International Nuclear Information System (INIS)

    Saito, Kazuhiro; Ishida, Jiro; Ito, Naoki; Kakizaki, Dai; Abe, Kimihiko; Kotake, Fumio

    2001-01-01

    Dynamic MRI with SH-U-555 (SPIO) was evaluated. Dynamic MRI was performed for 17 patients with 22 lesions. Dynamic study with T2 * -weighted imaging (T2 * dynamic) and T1-weighted imaging (T1 dynamic) were performed in 8 cases (10 lesions) and 9 cases (12 lesion), respectively. T2 * dynamic MR images were obtained before and 30, 90, 180, 270, 360, and 450 seconds and 31 minutes after the intravenous injection of SPIO, and T1 dynamic MR images were obtained before and 0, 40, 80, 120, 180, 240, 300, 360, 420, 480 seconds and 28 minutes after the injection of SPIO. The signal intensity of each lesion was measured before and after the injection of SPIO. The enhancement ratio of the lesions was calculated and evaluated. The enhancement ratio of hypervascular lesions decreased rapidly in the first phase of T2 * dynamic MRI, while that of hypovascular lesions decreased gradually. The enhancement ratio of hypervascular lesions increased in the first phase of T1 dynamic MRI and decreased gradually, while that of hypovascular lesions lacked the increase in the first phase, in contrast to hypervascular lesions. However, the changing of signal intensity could not be recognized on images with T2 * dynamic and T1 dynamic study. In conclusion, quantitative analysis using the enhancement ratio made it possible to anticipate lesion vascularity. (author)

  14. TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z; Shi, J; Yang, Y [University of Miami School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in the transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection

  15. Modeling Dynamic Contrast-Enhanced MRI Data with a Constrained Local AIF

    DEFF Research Database (Denmark)

    Duan, Chong; Kallehauge, Jesper F.; Pérez-Torres, Carlos J

    2018-01-01

    PURPOSE: This study aims to develop a constrained local arterial input function (cL-AIF) to improve quantitative analysis of dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) data by accounting for the contrast-agent bolus amplitude error in the voxel-specific AIF. PROCEDURES....... RESULTS: When the data model included the cL-AIF, tracer kinetic parameters were correctly estimated from in silico data under contrast-to-noise conditions typical of clinical DCE-MRI experiments. Considering the clinical cervical cancer data, Bayesian model selection was performed for all tumor voxels...

  16. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI; Multivariable Analyse klinischer Einflussfaktoren auf die Signalintensitaet bei Gd-EOB-DTPA 3T-MRT der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P. [University Hospital Regensburg (Germany). Dept. of Radiology; Zeman, F. [University Hospital Regensburg (Germany). Center for Clinical Trials; Teufel, A. [University Hospital Regensburg (Germany). Dept. of Gastroenterology; Lang, S. [University Hospital Regensburg (Germany). Dept. of Surgery

    2015-01-15

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  17. MR imaging findings of diffuse axonal injury: comparison of T2-weighted gradient images and T1- and T2-weighted spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seo Young; Lee, Ghi Jai; Kim, Jeong Seok; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To compare T2-weighted images with spin-echo T1- and turbo spin-echo (TSE) T2-weighted images in patients with diffuse axonal injury(DAI). Using a 1.0T MR unit, SE T1-, TSE T2-, and and FLASH T2-weighted images were obtained from 69 patients with a history of head trauma. In 18MR images of 17 patients with imaging findings of DAI, T2-weighted images were retrospectively compared with SE T1- and TSE T2-weighted images. The interval between trauma and MR scan varied from 5 days to 24(mean, 11) months. Focusing on the number of lesions, and their location and signal intensity, as weel as associated findings, three images were simultaueously evaluated. In 18 MR images of 17 patients with MR imaging findings of DAI, 21 lesions were detected on T1-weighted images, 28 on TSE T2-weighted images, and 70 on T2-weighted images;the last of these revealed all lesions detected on the other two. Most lesions were hypointense on T1-weighted images(17/21), hyperintense on TSE T2-weighted (21/28), and hypointense on T2-weighted (63/70). Common locations for DAI were the frontal lobe (n=3D35) and corpus callosum (n=3D22). Associated brain injuries were cortical contusion (n=3D5), brainstem injury (n=3D3), deep gray matter injury (n=3D2), and subdural hematoma(n=3D1). In patients with DAI. T2-weighted images can detect more lesions and associated petechial hemorrhage than can TSE T2-weighted images. This modality is thus useful for the evaluation of patients with head trauma.=20.

  18. A Case of Contiguous Primary Hepatic Marginal Zone B-Cell Lymphoma and Hemangioma Ultimately Diagnosed Using Contrast-Enhanced Ultrasonography

    Directory of Open Access Journals (Sweden)

    Kazue Shiozawa

    2015-02-01

    Full Text Available Primary hepatic marginal zone B-cell malignant lymphoma of mucosa-associated lymphoid tissue (MALT lymphoma is extremely rare. We present a case in which a lesion was diagnosed as 2 contiguous tumors (MALT lymphoma and hemangioma using contrast-enhanced ultrasonography (US with sonazoid. There has been no previous case of contiguous hepatic MALT lymphoma and hemangioma. The present case was a female with no medical history. We detected a snowman-like appearance, which was a tumor of 15 mm in diameter with hypo- and hyper-echogenicities in the lateral and medial parts, respectively, in the Couinaud's segment (S6 of the liver on US. The tumor appeared as a single lesion with a low-density area in the unenhanced phase and prolonged enhancement in the equilibrium phases on dynamic CT. On MRI, the whole lesion showed a low-intensity signal on T1-weighted imaging, but isointensity in the lateral part and high intensity in the medial part were seen on T2-weighted imaging. On contrast-enhanced US, the lateral hypoechoic region was homogenously hyperenhanced in the early vascular phase, and the contrast medium was washed out after about 30 s; in contrast, the medial hyperechoic region was gradually stained from the margin toward the central region. The tumor showed a defect in both hypo- and hyperechoic regions in the postvascular phase. Hemangioma was suspected for the medial part based on the typical image findings, but the lateral part was not given a diagnosis. Thus, surgical resection was performed. The medial part was a hemangioma, and the lateral part was a MALT lymphoma by histopathological findings.

  19. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias; Gieseke, Juergen; Willinek, Winfried

    2018-01-01

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  20. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias [University Hospital Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [Philips Healthcare Germany, Hamburg (Germany); Willinek, Winfried [Hospital of Barmherzige Brueder, Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Trier (Germany)

    2018-01-15

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  1. Dynamic Contrast Enhanced Magnetic Resonance Imaging of Diffuse Spinal Bone Marrow Infiltration in Patients with Hematological Malignancies

    International Nuclear Information System (INIS)

    Zha, Yunfei; Li, Maojin; Yang, Jianyong

    2010-01-01

    To investigate the significance of the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) parameters of diffuse spinal bone marrow infiltration in patients with hematological malignancies. Dynamic gadolinium-enhanced MR imaging of the lumbar spine was performed in 26 patients with histologically proven diffuse bone marrow infiltration, including multiple myeloma (n = 6), acute lymphoblastic leukemia (n = 6), acute myeloid leukemia (n = 5), chronic myeloid leukemia (n = 7), and non-Hodgkin lymphoma (n = 2). Twenty subjects whose spinal MRI was normal, made up the control group. Peak enhancement percentage (E max ), enhancement slope (ES), and time to peak (TTP) were determined from a time intensity curve (TIC) of lumbar vertebral bone marrow. A comparison between baseline and follow-up MR images and its histological correlation were evaluated in 10 patients. The infiltration grade of hematopoietic marrow with plasma cells was evaluated by a histological assessment of bone marrow. Differences in E max , ES, and TTP values between the control group and the patients with diffuse bone marrow infiltration were significant (t = -11.51, -9.81 and 3.91, respectively, p max , ES, and TTP values were significantly different between bone marrow infiltration groups Grade 1 and Grade 2 (Z = -2.72, -2.24 and -2.89 respectively, p max , ES and TTP values were not significantly different between bone marrow infiltration groups Grade 2 and Grade 3 (Z = -1.57, -1.82 and -1.58 respectively, p > 0.05). A positive correlation was found between E max , ES values and the histological grade of bone marrow infiltration (r = 0.86 and 0.84 respectively, p max and ES values was observed with increased TTP values after treatment in all of the 10 patients who responded to treatment (t = -7.92, -4.55, and 5.12, respectively, p max , ES, and TTP can reflect the malignancies' histological grade

  2. Primary pulmonary low-grade angiosarcoma characterized by mismatch between {sup 18}F-FDG FET and dynamic contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Eun Young; Lee, Ho Yun; Han, Joung Ho; Choi, Joon Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    We report a rare case of primary pulmonary low-grade angiosarcoma on dynamic contrast-enhanced CT and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT imaging. A 38-year-old, asymptomatic woman was hospitalized because of an abnormality on chest radiography. A dynamic contrast-enhanced chest CT showed a 1.2 cm-sized irregular-margined nodule with strong and persistent enhancement in the right lower lobe. The lesion had low metabolic activity on an {sup 18}F-FDG PET/CT scan. The patient underwent a wedge resection for the lesion, and pathology revealed a primary pulmonary low-grade angiosarcoma.

  3. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  4. Dynamic contrast enhancement in widefield microscopy using projector-generated illumination patterns

    International Nuclear Information System (INIS)

    Samson, Edward Carlo; Blanca, Carlo Mar

    2007-01-01

    We present a simple and cost-effective optical protocol to realize contrast-enhancement imaging (such as dark-field, optical-staining and oblique illumination microscopy) of transparent samples on a conventional widefield microscope using commercial multimedia projectors. The projector functions as both light source and mask generator implemented by creating slideshows of the filters projected along the illumination planes of the microscope. The projected optical masks spatially modulate the distribution of the incident light to selectively enhance structures within the sample according to spatial frequency thereby increasing the image contrast of translucent biological specimens. Any amplitude filter can be customized and dynamically controlled so that switching from one imaging modality to another involves a simple slide transition and can be executed at a keystroke with no physical filters and no moving optical parts. The method yields an image contrast of 89-96% comparable with standard enhancement techniques. The polarization properties of the projector are then utilized to discriminate birefringent and non-birefringent sites on the sample using single-shot, simultaneous polarization and optical-staining microscopy. In addition to dynamic pattern generation and polarization, the projector also provides high illumination power and spectral excitation selectivity through its red-green-blue (RGB) channels. We exploit this last property to explore the feasibility of using video projectors to selectively excite stained samples and perform fluorescence imaging in tandem with reflectance and polarization reflectance microscopy

  5. Sensitivity of susceptibility-weighted imaging in detecting developmental venous anomalies and associated cavernomas and microhemorrhages in children

    International Nuclear Information System (INIS)

    Young, Allen; Bosemani, Thangamadhan; Goel, Reema; Huisman, Thierry A.G.M.; Poretti, Andrea

    2017-01-01

    Developmental venous anomalies (DVA) are common neuroimaging abnormalities that are traditionally diagnosed by contrast-enhanced T1-weighted images as the gold standard. We aimed to evaluate the sensitivity of SWI in detecting DVA and associated cavernous malformations (CM) and microhemorrhages in children in order to determine if SWI may replace contrast-enhanced MRI sequences. Contrast-enhanced T1-weighted images were used as diagnostic gold standard for DVA. The presence of DVA was qualitatively assessed on axial SWI and T2-weighted images by an experienced pediatric neuroradiologist. In addition, the presence of CM and microhemorrhages was evaluated on SWI and contrast-enhanced T1-weighted images. Fifty-seven children with DVA (34 males, mean age at neuroimaging 11.2 years, range 1 month to 17.9 years) were included in this study. Forty-nine out of 57 DVA were identified on SWI (sensitivity of 86%) and 16 out of 57 DVA were detected on T2-weighted images (sensitivity of 28.1%). General anesthesia-related changes in brain hemodynamics and oxygenation were most likely responsible for the majority of SWI false negative. CM were detected in 12 patients on axial SWI, but only in six on contrast-enhanced T1-weighted images. Associated microhemorrhages could be identified in four patients on both axial SWI and contrast-enhanced T1-weighted images, although more numerous and conspicuous on SWI. SWI can identify DVA and associated cavernous malformations and microhemorrhages with high sensitivity, obviating the need for contrast-enhanced MRI sequences. (orig.)

  6. Sensitivity of susceptibility-weighted imaging in detecting developmental venous anomalies and associated cavernomas and microhemorrhages in children

    Energy Technology Data Exchange (ETDEWEB)

    Young, Allen; Bosemani, Thangamadhan; Goel, Reema; Huisman, Thierry A.G.M. [The Johns Hopkins School of Medicine, Charlotte R. Bloomberg Children' s Center, Division of Pediatric Radiology and Pediatric Neuroradiology, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Poretti, Andrea [The Johns Hopkins School of Medicine, Charlotte R. Bloomberg Children' s Center, Division of Pediatric Radiology and Pediatric Neuroradiology, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Kennedy Krieger Institute, Department of Neurogenetics, Baltimore, MD (United States)

    2017-08-15

    Developmental venous anomalies (DVA) are common neuroimaging abnormalities that are traditionally diagnosed by contrast-enhanced T1-weighted images as the gold standard. We aimed to evaluate the sensitivity of SWI in detecting DVA and associated cavernous malformations (CM) and microhemorrhages in children in order to determine if SWI may replace contrast-enhanced MRI sequences. Contrast-enhanced T1-weighted images were used as diagnostic gold standard for DVA. The presence of DVA was qualitatively assessed on axial SWI and T2-weighted images by an experienced pediatric neuroradiologist. In addition, the presence of CM and microhemorrhages was evaluated on SWI and contrast-enhanced T1-weighted images. Fifty-seven children with DVA (34 males, mean age at neuroimaging 11.2 years, range 1 month to 17.9 years) were included in this study. Forty-nine out of 57 DVA were identified on SWI (sensitivity of 86%) and 16 out of 57 DVA were detected on T2-weighted images (sensitivity of 28.1%). General anesthesia-related changes in brain hemodynamics and oxygenation were most likely responsible for the majority of SWI false negative. CM were detected in 12 patients on axial SWI, but only in six on contrast-enhanced T1-weighted images. Associated microhemorrhages could be identified in four patients on both axial SWI and contrast-enhanced T1-weighted images, although more numerous and conspicuous on SWI. SWI can identify DVA and associated cavernous malformations and microhemorrhages with high sensitivity, obviating the need for contrast-enhanced MRI sequences. (orig.)

  7. Salivary gland masses. Dynamic MR imaging and pathologic correlation

    International Nuclear Information System (INIS)

    Park, Jinho; Inoue, Shingo; Ishizuka, Yasuhito; Shindo, Hiroaki; Kawanishi, Masayuki; Kakizaki, Dai; Abe, Kimihiko; Ebihara, Yoshiro

    1997-01-01

    To evaluate the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI) for the diagnosis of salivary gland masses. We retrospectively examined 19 salivary gland masses that were pathologically diagnosed by surgical operation or biopsy. We obtained T1- and T2-weighted images on MRI, performed dynamic studies on each mass and examined the correlation between enhancement patterns and pathological findings. Four enhancement patterns were recognized on contrast-enhanced MRI: type 1 showed marked, homogeneous enhancement; type 2 slights, homogeneous enhancement; type 3 marginal enhancement; and type 4 poor enhancement of the mass. Most pleomorphic adenomas had a type 1 enhancement pattern, but two had a type 2 pattern. Pathologically, each mass enhancement pattern had different tumor cell and matrix components. Warthin's tumor generally showed the type 4 pattern. Primary malignant tumors of the salivary gland all showed the type 3 pattern, and pathological specimens showed many tumor cells along the marginal portion of the tumor. One inflammatory cyst and one Warthin's tumor also showed the type 3 pattern. Except for metastatic renal cell carcinoma, the enhancement patterns of late phase images and dynamic study images were the same. Dynamic MRI added little diagnostic information about salivary gland masses, but the contrast-enhanced MR features correlated well with the pathological findings. (author)

  8. Histopathologic diversity of gastric cancers: Relationship between enhancement pattern on dynamic contrast-enhanced CT and histological type.

    Science.gov (United States)

    Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Muraki, Toshio; Nishie, Akihiro; Asayama, Yoshiki; Oki, Eiji; Oda, Yoshinao; Honda, Hiroshi

    2017-12-01

    To evaluate the diagnostic value of contrast-enhanced computed tomography gastrography (CE-CTG) to predict the histological type of gastric cancer. We analyzed 47 consecutive patients with resectable advanced gastric cancer preoperatively evaluated by multiphasic dynamic contrast-enhanced CT. Two radiologists independently reviewed the CT images and they determined the peak enhancement phase, and then measured the CT attenuation value of the gastric lesion for each phase. The histological types of gastric cancers were assigned to three groups as differentiated-type, undifferentiated-type, and mixed-type. We compared the peak enhancement phase of the three types and compared the CT attenuation values in each phase. The peak enhancement was significantly different between the three types of gastric cancers for both readers (reader 1, p=0.001; reader 2, p=0.009); most of the undifferentiated types had peak enhancement in the delayed phase. The CT attenuation values of undifferentiated type were significantly higher than those of differentiated or mixed type in the delayed phase according to both readers (reader 1, p=0.002; reader 2, p=0.004). CE-CTG could provide helpful information in diagnosing the histological type of gastric cancers preoperatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Differentiation of mass-forming focal pancreatitis from pancreatic ductal adenocarcinoma: value of characterizing dynamic enhancement patterns on contrast-enhanced MR images by adding signal intensity color mapping

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mimi [Hanyang University College of Medicine, Department of Radiology, Hanyang Medical Center, Seoul (Korea, Republic of); Jang, Kyung Mi [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jae-Hun; Jeong, Woo Kyoung; Kim, Seong Hyun; Kang, Tae Wook; Kim, Young Kon; Cha, Dong Ik [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Kyunga [Samsung Medical Center, Biostatics and Clinical Epidemiology Center, Research Institute for Future Medicine, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate the value of dynamic enhancement patterns on contrast-enhanced MR images by adding signal intensity colour mapping (SICM) to differentiate mass-forming focal pancreatitis (MFFP) from pancreatic ductal adenocarcinoma (PDAC). Forty-one clinicopathologically proven MFFPs and 144 surgically confirmed PDACs were enrolled. Laboratory and MR imaging parameters were used to differentiate MFFP from PDAC. In particular, enhancement patterns on MR images adding SICM were evaluated. By using classification tree analysis (CTA), we determined the predictors for the differentiation of MFFP from PDAC. In the CTA, with all parameters except enhancement pattern on SICM images, ductal obstruction grade and T1 hypointensity grade of the pancreatic lesion were the first and second splitting predictor for differentiation of MFFP from PDAC, in order. By adding an enhancement pattern on the SICM images to CTA, the enhancement pattern was the only splitting predictor to differentiate MFFP from PDAC. The CTA model including enhancement pattern on SICM images has sensitivity of 78.0 %, specificity of 99.3 %, and accuracy of 94.6 % for differentiating MFFP from PDAC. The characterization of enhancement pattern for pancreatic lesions on contrast-enhanced MR images adding SICM would be helpful to differentiate MFFP from PDAC. (orig.)

  10. Discrimination between glioma grades II and III in suspected low-grade gliomas using dynamic contrast-enhanced and dynamic susceptibility contrast perfusion MR imaging

    DEFF Research Database (Denmark)

    Falk, Anna; Fahlström, Markus; Rostrup, Egill

    2014-01-01

    INTRODUCTION: Perfusion magnetic resonance imaging (MRI) can be used in the pre-operative assessment of brain tumours. The aim of this prospective study was to identify the perfusion parameters from dynamic contrast-enhanced (DCE) and dynamic susceptibility contrast (DSC) perfusion imaging...... written informed consent in this review board-approved study. Regions of interests (ROIs) in tumour area were delineated on FLAIR images co-registered to DCE and DSC, respectively, in 25 patients with histopathological grade II (n = 18) and III (n = 7) gliomas. Statistical analysis of differences between...

  11. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 X-ray mammography findings

    Energy Technology Data Exchange (ETDEWEB)

    Bickelhaupt, Sebastian; Tesdorff, Jana; Delorme, Stefan; Schlemmer, Heinz-Peter [German Cancer Research Center (dkfz), Department of Radiology, Heidelberg (Germany); Laun, Frederik Bernd; Kuder, Tristan Anselm [German Cancer Research Center (dkfz), Medical Physics in Radiology, Heidelberg (Germany); Lederer, Wolfgang; Teiner, Susanne [Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg (Germany); Maier-Hein, Klaus [German Cancer Research Center (dkfz), Junior Group Medical Image Computing, Heidelberg (Germany); Daniel, Heidi [Radiology Center Mannheim (RZM), Mannheim (Germany); Stieber, Anne [University Hospital Heidelberg, Department of Clinical and Interventional Radiology, Heidelberg (Germany)

    2017-02-15

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm{sup 2}). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. (orig.)

  12. MR imaging pulse sequence rationale: SD-, T1-, and T2-weighted images

    International Nuclear Information System (INIS)

    Sax, S.; Weathers, S.W.; Schneiders, N.J.; Horowitz, B.L.; Mawad, M.E.; Sandlin, M.E.; Blackwell, R.; Bryan, R.N.

    1986-01-01

    Over 500 patients have been examined with a pulse sequence designed to provide spin-density (SD)-weighted images (TR=3 sec, TE=35 msec), T1-weighted images (TR=0.3 sec, TE=35msec), and T2-weighted images (TR=3 sec, TE=105 msec) from which calculated ''synthesized'' images and SD, T1, and T2 calculated images could be obtained. Each image contributes unique information. SD-weighted images optimally display anatomy and often best highlight pathology. T1-weighted images are critical in assessing cerebral hemorrhages. T2-weighted images best display most lesions, but yield incomplete information in 35% of cases. All three types of ''weighted'' images are necessary to optimally display anatomy and fully characterize a lesion. Computerized calculations and simulations suggest that no other combination of pulse sequences yields equal information for a given examination time

  13. Usefulness of dynamic MR imaging for the evaluation of transcatheter arterial embolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kyomasu, Yoshinori; Nakayama, Masafumi; Kawakami, Mutsumi; Mashima, Yasuoki; Ichinose, Akira; Endou, Kazuo; Chiba, Kazuo; Tanno, Munehiko; Yamada, Hideo

    1992-01-01

    Thirteen patients with hepatocellular carcinoma (HCC) were studied with dynamic MR imaging in addition to conventional T 1 - and T 2 -weighted and enhanced T 1 -weighted images before and after the treatment of HCC by transcatheter arterial embolization (TAE). Dynamic MR imaging was performed using GRASS (gradient recalled acquisition in the steady state) sequences. The imaging was started at 10 seconds after rapid injection of Gd-diethylenetriaminepentaacetic acid (Gd-DTPA) with 6s breath hold. Thereafter about 12 images were obtained during 6s breath-holding with 20 seconds intervals. On T 1 - and T 2 -weighted images, signal intensity at the tumor tended to increase during the early period after TAE and to decrease later. Intensities of the HCC, however, were heterogeneous. Differentiation among embolic area, necrosis, viable cells and recurrent area, was often difficult only by conventional images. Dynamic GRASS images could clearly demonstrate an embolic area as a region without contrast enhancement. While recurrent tumor could be diagnosed as an area with early enhancement at the arterial phase. Development of the collateral circulation and dominancy of tumor feeding vessels after TAE could also be deduced on dynamic MR images together with enhanced T 1 -weighted images. The dynamic MR imaging was concluded to be a potentially useful procedure for the clinical evaluation of HCC after TAE. (author)

  14. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  15. Contrast-enhanced FLAIR in the early diagnosis of infectious meningitis

    International Nuclear Information System (INIS)

    Splendiani, Alesssandra; Puglielli, Edoardo; Amicis, Rosanna De; Masciocchi, Carlo; Gallucci, Massimo; Necozione, Stefano

    2005-01-01

    We investigated the accuracy of MRI in the early diagnosis of infectious meningitis with emphasis on the value of gadolinium-enhanced fluid-attenuated inversion recovery (FLAIR) sequence. Twenty-seven patients with clinical suspicion of infectious meningitis were included. MRI was performed within 3 h of clinical evaluation. For all patients, T1-weighted spin-echo, dual-echo T2-weighted fast-spin-echo and FLAIR sequences were performed, followed by gadolinium-enhanced T1-weighted spin-echo and FLAIR sequences. Final diagnosis was based on the clinical findings and the analysis of cerebrospinal fluid, obtained by lumbar puncture after the MRI. Infectious meningitis was confirmed in 12 patients. In all of these patients of the plain studies, FLAIR was positive in only four patients. MRI gadolinium-enhanced FLAIR showed abnormal meningeal enhancement in all 12 patients, while gadolinium-enhanced T1-weighted spin-echo was positive only in six cases. There were no false-positive or false-negative results. It is concluded that MRI could have an important role in the early screening for infectious meningitis, provided a gadolinium-enhanced FLAIR sequence is used. (orig.)

  16. Contrast-enhanced FLAIR in the early diagnosis of infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Splendiani, Alesssandra; Puglielli, Edoardo; Amicis, Rosanna De; Masciocchi, Carlo; Gallucci, Massimo [University of L' Aquila, Department of Radiology, L' Aquila (Italy); Necozione, Stefano [University of L' Aquila, Department of Statistic, L' Aquila (Italy)

    2005-08-01

    We investigated the accuracy of MRI in the early diagnosis of infectious meningitis with emphasis on the value of gadolinium-enhanced fluid-attenuated inversion recovery (FLAIR) sequence. Twenty-seven patients with clinical suspicion of infectious meningitis were included. MRI was performed within 3 h of clinical evaluation. For all patients, T1-weighted spin-echo, dual-echo T2-weighted fast-spin-echo and FLAIR sequences were performed, followed by gadolinium-enhanced T1-weighted spin-echo and FLAIR sequences. Final diagnosis was based on the clinical findings and the analysis of cerebrospinal fluid, obtained by lumbar puncture after the MRI. Infectious meningitis was confirmed in 12 patients. In all of these patients of the plain studies, FLAIR was positive in only four patients. MRI gadolinium-enhanced FLAIR showed abnormal meningeal enhancement in all 12 patients, while gadolinium-enhanced T1-weighted spin-echo was positive only in six cases. There were no false-positive or false-negative results. It is concluded that MRI could have an important role in the early screening for infectious meningitis, provided a gadolinium-enhanced FLAIR sequence is used. (orig.)

  17. Metastatic spinal tumor. Assessment with fat-saturation T1-weighted MR imaging

    International Nuclear Information System (INIS)

    Kasai, Toshifumi; Sugimura, Kazuro; Uchida, Nobue; Kawamitsu, Hideaki; Komatsu, Akio; Okui, Shouji; Kimino, Katsuji.

    1994-01-01

    The purpose of this study was to compare conventional T1-weighted imaging (T1-WI) and chemical shift fat-saturation T1-weighted imaging (fat-sat T1-WI) by a diagnosis of the bone metastases. Thirty-two patients (143 vertebrae) with non-neoplastic lesions (normal group) and 32 patients (82 vertebrae) with spinal metastases (metastatic group) were evaluated using both images. The signal intensity (SI) distribution of both groups regarding T1-WI provided various patterns, and the SI measurements were not significantly different between the two groups ; however, the metastases which were mixed, showed a low SI. Regarding fat-sat T1-WI, all non-neoplastic lesions had a low-intensity homogeneous appearance ; however, the metastases were mixed to a high SI. The SI measurement data of the metastatic group was significantly higher than that of the normal group. In conclusion, fat-sat T1-WI was useful for evaluating the vertebral metastases. When fat-sat T1-WI demonstrated a mixed to high SI in patients suspected of having vertebral metastasis, Gd-DTPA enhancement was thought to be the problem. (author)

  18. Diagnosis of breast masses from dynamic contrast-enhanced and diffusion-weighted MR: a machine learning approach.

    Directory of Open Access Journals (Sweden)

    Hongmin Cai

    Full Text Available PURPOSE: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI is increasingly used for breast cancer diagnosis as supplementary to conventional imaging techniques. Combining of diffusion-weighted imaging (DWI of morphology and kinetic features from DCE-MRI to improve the discrimination power of malignant from benign breast masses is rarely reported. MATERIALS AND METHODS: The study comprised of 234 female patients with 85 benign and 149 malignant lesions. Four distinct groups of features, coupling with pathological tests, were estimated to comprehensively characterize the pictorial properties of each lesion, which was obtained by a semi-automated segmentation method. Classical machine learning scheme including feature subset selection and various classification schemes were employed to build prognostic model, which served as a foundation for evaluating the combined effects of the multi-sided features for predicting of the types of lesions. Various measurements including cross validation and receiver operating characteristics were used to quantify the diagnostic performances of each feature as well as their combination. RESULTS: Seven features were all found to be statistically different between the malignant and the benign groups and their combination has achieved the highest classification accuracy. The seven features include one pathological variable of age, one morphological variable of slope, three texture features of entropy, inverse difference and information correlation, one kinetic feature of SER and one DWI feature of apparent diffusion coefficient (ADC. Together with the selected diagnostic features, various classical classification schemes were used to test their discrimination power through cross validation scheme. The averaged measurements of sensitivity, specificity, AUC and accuracy are 0.85, 0.89, 90.9% and 0.93, respectively. CONCLUSION: Multi-sided variables which characterize the morphological, kinetic, pathological

  19. Diagnosis of breast masses from dynamic contrast-enhanced and diffusion-weighted MR: a machine learning approach.

    Science.gov (United States)

    Cai, Hongmin; Peng, Yanxia; Ou, Caiwen; Chen, Minsheng; Li, Li

    2014-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly used for breast cancer diagnosis as supplementary to conventional imaging techniques. Combining of diffusion-weighted imaging (DWI) of morphology and kinetic features from DCE-MRI to improve the discrimination power of malignant from benign breast masses is rarely reported. The study comprised of 234 female patients with 85 benign and 149 malignant lesions. Four distinct groups of features, coupling with pathological tests, were estimated to comprehensively characterize the pictorial properties of each lesion, which was obtained by a semi-automated segmentation method. Classical machine learning scheme including feature subset selection and various classification schemes were employed to build prognostic model, which served as a foundation for evaluating the combined effects of the multi-sided features for predicting of the types of lesions. Various measurements including cross validation and receiver operating characteristics were used to quantify the diagnostic performances of each feature as well as their combination. Seven features were all found to be statistically different between the malignant and the benign groups and their combination has achieved the highest classification accuracy. The seven features include one pathological variable of age, one morphological variable of slope, three texture features of entropy, inverse difference and information correlation, one kinetic feature of SER and one DWI feature of apparent diffusion coefficient (ADC). Together with the selected diagnostic features, various classical classification schemes were used to test their discrimination power through cross validation scheme. The averaged measurements of sensitivity, specificity, AUC and accuracy are 0.85, 0.89, 90.9% and 0.93, respectively. Multi-sided variables which characterize the morphological, kinetic, pathological properties and DWI measurement of ADC can dramatically improve the

  20. Fundamentals of quantitative dynamic contrast-enhanced MR imaging.

    Science.gov (United States)

    Paldino, Michael J; Barboriak, Daniel P

    2009-05-01

    Quantitative analysis of dynamic contrast-enhanced MR imaging (DCE-MR imaging) has the power to provide information regarding physiologic characteristics of the microvasculature and is, therefore, of great potential value to the practice of oncology. In particular, these techniques could have a significant impact on the development of novel anticancer therapies as a promising biomarker of drug activity. Standardization of DCE-MR imaging acquisition and analysis to provide more reproducible measures of tumor vessel physiology is of crucial importance to realize this potential. The purpose of this article is to review the pathophysiologic basis and technical aspects of DCE-MR imaging techniques.

  1. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Balvay, Daniel; Aubert, Emilie; Bazot, Marc; Darai, Emile; Rouzier, Roman; Cuenod, Charles A.

    2012-01-01

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F T ), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F T , Vb, rAUC and lower Ve than benign tumours (P T was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F T and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  2. Dynamic contrast-enhanced magnetic resonance imaging: a non-invasive method to evaluate significant differences between malignant and normal tissue

    International Nuclear Information System (INIS)

    Rudisch, Ansgar; Kremser, Christian; Judmaier, Werner; Zunterer, Hildegard; DeVries, Alexander F.

    2005-01-01

    Purpose: An ever recurring challenge in diagnostic radiology is the differentiation between non-malignant and malignant tissue. Based on evidence that microcirculation of normal, non-malignant tissue differs from that of malignant tissue, the goal of this study was to assess the reliability of dynamic contrast-enhanced Magnetic Resonance Imaging (dcMRI) for differentiating these two entities. Materials and methods: DcMRI data of rectum carcinoma and gluteus maximus muscles were acquired in 41 patients. Using an fast T1-mapping sequence on a 1.5-T whole body scanner, T1-maps were dynamically retrieved before, during and after constant rate i.v. infusion of a contrast medium (CM). On the basis of the acquired data sets, PI-values were calculated on a pixel-by-pixel basis. The relevance of spatial heterogeneities of microcirculation was investigated by relative frequency histograms of the PI-values. Results: A statistically significant difference between malignant and normal tissue was found for the mean PI-value (P < 0.001; 8.95 ml/min/100 g ± 2.45 versus 3.56 ml/min/100 g ± 1.20). Additionally relative frequency distributions of PI-values with equal class intervals of 2.5 ml/min/100 g revealed significant differences between the histograms of muscles and rectum carcinoma. Conclusion: We could show that microcirculation differences between malignant and normal, non-malignant tissue can be reliably assessed by non-invasive dcMRI. Therefore, dcMRI holds great promise in the aid of cancer assessment, especially in patients where biopsy is contraindicated

  3. Differentiation of benign and malignant solitary pulmonary nodules : value of contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Kim, Jeong Ho; Kim, Hyung Jin; Han, Heon; Lee, Hong Lyeol; Kim, Kwang Ho; Suh, Chang Hae

    1999-01-01

    To evaluate the usefulness of contrast-enhanced dynamic MR imaging for differentiation of benign and malignant solitary pulmonary nodules (SPNs). Twenty-three patients with histologically or radiologically provened SPNs smaller than 40mm (14 benign, 9 malignant) underwent MR examination using the breath-hold fast multiplanar spoiled gradient echo (FMPSPGR) technique. Pre-enhancement MR examination was followed by serial scans obtained at one-minute intervals, beginning one-minute after the onset of bolus injection of paramagnetic contrast agent for a total of five scans. Signal intensities of SPNs were measured from pre- and post-contrast enhanced MR images and peak percentage increase in signal intensity (p%SI) was calculated. Mean percentage increase in signal intensity (m%SI) was also calculated and the time-m%SI curve was plotted. The enhancement patterns of SPNs were classified as homogeneous, peripheral rim-like, inhomogeneous, or no (or minimal) enhancement. We compared differences in p%SI, the pattern of the time-m%SI curve, and the pattern of enhancement between benign and malignant SPNs. On dynamic MR images, alignant SPNs (n=9) showed a significantly higher p%SI than benign SPNs (n=14) (malignant : mean 120.6, range 81.8-171.6; benign : mean 29.5, range 3.7-78.9)(p<0.0001). With 80 p%SI as the threshold for malignancy-positive, both sensitivity and specificity were 100%. The m%SI of malignant SPNs rapidly increased at one minute after enhancement and decreased gradually thereafter, whereas that of benign SPNs increased more slowly to form a plateau. Eighty-nine percent (8/9) of malignant SPNs showed homogeneous enhancement. In contrast, among benign SPNs, peripheral rim-like enhancement and no (or minimal) enhancement occurred in the same proportion of cases : 50%(7/14). The superb demonstration of different enhancement characteristics obtained using dynamic contrast-enhanced MR imaging is useful to discriminate malignant from benign SPNs

  4. The effect of blood inflow and B(1)-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Roberts, Caleb; Little, Ross; Watson, Yvonne; Zhao, Sha; Buckley, David L; Parker, Geoff J M

    2011-01-01

    A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow. © 2010 Wiley-Liss, Inc.

  5. Eu, Gd-Codoped Yttria Nanoprobes for Optical and T1-Weighted Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Timur Sh Atabaev

    2017-02-01

    Full Text Available Nanoprobes with multimodal functionality have attracted significant interest recently because of their potential applications in nanomedicine. This paper reports the successful development of lanthanide-doped Y2O3 nanoprobes for potential applications in optical and magnetic resonance (MR imaging. The morphology, structural, and optical properties of these nanoprobes were characterized by transmission electron microscope (TEM, field emission scanning electron microscope (FESEM, X-ray diffraction (XRD, energy-dispersive X-ray (EDX, and photoluminescence (PL. The cytotoxicity test showed that the prepared lanthanide-doped Y2O3 nanoprobes have good biocompatibility. The obvious contrast enhancement in the T1-weighted MR images suggested that these nanoprobes can be used as a positive contrast agent in MRI. In addition, the clear fluorescence images of the L-929 cells incubated with the nanoprobes highlight their potential for optical imaging. Overall, these results suggest that prepared lanthanide-doped Y2O3 nanoprobes can be used for simultaneous optical and MR imaging.

  6. Study of proximal femoral bone perfusion with 3D T1 dynamic contrast-enhanced MRI: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Budzik, Jean-Francois [Groupe Hospitalier de l' Institut Catholique de Lille / Faculte Libre de Medecine, Service d' Imagerie Medicale, Lille (France); Centre de Consultation et d' Imagerie de l' Appareil Locomoteur, CHRU de Lille, Service de Radiologie et Imagerie Musculosquelettique, Lille (France); Universite Catholique de Lille, Lille (France); Universite Nord de France, Lille (France); EA 4490 PMOI (Physiopathologie des Maladies Osseuses Inflammatoires) IFR 114 PRES Universite Lille Nord de France, Lille (France); Lefebvre, Guillaume; El Rafei, Mazen [Centre de Consultation et d' Imagerie de l' Appareil Locomoteur, CHRU de Lille, Service de Radiologie et Imagerie Musculosquelettique, Lille (France); Universite Nord de France, Lille (France); CHU Lille, Lille (France); Forzy, Gerard [Universite Catholique de Lille, Lille (France); Universite Nord de France, Lille (France); Groupe Hospitalier de l' Institut Catholique de Lille, Laboratoire de Biologie, Departement de Biostatistiques, Lille (France); Chechin, David [Philips Medical Systems, Suresnes (France); Cotten, Anne [Centre de Consultation et d' Imagerie de l' Appareil Locomoteur, CHRU de Lille, Service de Radiologie et Imagerie Musculosquelettique, Lille (France); Universite Nord de France, Lille (France); EA 4490 PMOI (Physiopathologie des Maladies Osseuses Inflammatoires) IFR 114 PRES Universite Lille Nord de France, Lille (France); CHU Lille, Lille (France)

    2014-12-15

    The objective of this study was to compare measurements of semi-quantitative and pharmacokinetic parameters in areas of red (RBM) and yellow bone marrow (YBM) of the hip, using an in-house high-resolution DCE T1 sequence, and to assess intra- and inter-observer reproducibility of these measurements. The right hips of 21 adult patients under 50 years of age were studied. Spatial resolution was 1.8 x 1.8 x 1.8 mm{sup 3}, and temporal resolution was 13.5 seconds. Two musculoskeletal radiologists independently processed DCE images and measured semi-quantitative and pharmacokinetic parameters in areas of YBM and RBM. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Intra- and inter-observer reproducibility was assessed. Area under the curve (AUC) and initial slope (IS) were significantly greater for RBM than for YBM (p < 0.05). K{sup trans} and k{sub ep} were also significantly greater for RBM (p < 0.05). There was no significant difference in time to peak between the regions (p < 0.05). SNR, CNR, and intra- and inter-observer reproducibility were all good. DCE study of the whole hip is feasible with high spatial resolution using a 3D T1 sequence. Measures were possible even in low vascularized areas of the femoral head. K{sup trans}, k{sub ep}, AUC, and IS values were significantly different between red and yellow marrow, whereas TTP values were not. (orig.)

  7. ``Smart'' theranostic lanthanide nanoprobes with simultaneous up-conversion fluorescence and tunable T1-T2 magnetic resonance imaging contrast and near-infrared activated photodynamic therapy

    Science.gov (United States)

    Zhang, Yan; Das, Gautom Kumar; Vijayaragavan, Vimalan; Xu, Qing Chi; Padmanabhan, Parasuraman; Bhakoo, Kishore K.; Tamil Selvan, Subramanian; Tan, Timothy Thatt Yang

    2014-10-01

    The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent.The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr01717j

  8. Leptomeningeal Contrast Enhancement Is Associated with Disability Progression and Grey Matter Atrophy in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gleb Makshakov

    2017-01-01

    Full Text Available Leptomeningeal contrast enhancement (LMCE on magnetic resonance imaging (MRI is a newly recognized possible biomarker in multiple sclerosis (MS, associated with MS progression and cortical atrophy. In this study, we aimed to assess the prevalence of LMCE foci and their impact on neurodegeneration and disability. Materials. 54 patients with MS were included in the study. LMCE were detected with a 3 Tesla scanner on postcontrast fluid-attenuated inversion-recovery (FLAIR sequence. Expanded Disability Status Scale (EDSS score, number of relapses during 5 years from MS onset, and number of contrast-enhancing lesions on T1 weighted MRI were counted. Results. LMCE was detected in 41% (22/54 of patients. LMCE-positive patients had longer disease duration (p=0,0098 and higher EDSS score (p=0,039, but not a higher relapse rate (p=0,091. No association of LMCE with higher frequency of contrast-enhancing lesions on T1-weighted images was detected (p=0,3842. Analysis of covariates, adjusted for age, sex, and disease duration, revealed a significant effect of LMCE on the cortex volume (p=0.043, F=2.529, the total grey matter volume (p=0.043, F=2.54, and total ventricular volume (p=0.039, F=2.605. Conclusions. LMCE was shown to be an independent and significant biomarker of grey matter atrophy and disability in MS.

  9. Quantification of synovitis in the cranio-cervical region: Dynamic contrast enhanced and diffusion weighted magnetic resonance imaging in early rheumatoid arthritis-A feasibility follow up study

    Energy Technology Data Exchange (ETDEWEB)

    Jeromel, M., E-mail: miran.jeromel@gmail.com [Institute of Radiology, Department for Neuroradiology, University Medical Centre Ljubljana, Zaloska cesta 2, 1000 Ljubljana (Slovenia); Jevtic, V., E-mail: vladimir.jevtic@mf.uni-lj.si [Medical Faculty Ljubljana, Vrazov trg 2, 1104 Ljubljana (Slovenia); Sersa, I., E-mail: igor.sersa@ijs.si [Jozef Stefan Institute, Jamova cesta 39, 1000 Ljubljana (Slovenia); Ambrozic, A., E-mail: ales.ambrozic@mf.uni-lj.si [Department of Rheumatology, University Medical Centre Ljubljana, Vodnikova 62, 1000 Ljubljana (Slovenia); Tomsic, M., E-mail: matija.tomsic@kclj.si [Department of Rheumatology, University Medical Centre Ljubljana, Vodnikova 62, 1000 Ljubljana (Slovenia)

    2012-11-15

    Objective: To test the feasibility of dynamic contrast enhanced (DCEI) and diffusion weighted (DWI) magnetic resonance imaging (MRI) for quantifying synovitis of the cranio-cervical (C-C) region in patients with early rheumatoid arthritis (RA) and neck pain at the beginning and at a six month follow up. Methods: 27 patients with duration of RA of less than 24 months and neck pain were studied with standard qualitative MRI evaluation and two quantitative MRI methods (DCEI and DWI) at the level of atlantoaxial joints. Rate of early enhancement (REE), enhancement gradient (Genh) and apparent diffusion coefficient (ADC) were extracted from DCEI and DWI data. MRI was coupled with clinical assessment and radiographic imaging. Results: Using standard qualitative MRI evaluation, unequivocal active synovitis (grade 2 or 3 contrast enhancement) was proved in 16 (59%) patients at baseline and 14 (54%) at follow up. DCEI and DWI measurements confirmed active synovitis in 25 (93%) patients at baseline and 24 (92%) at follow up. Average REE, Genh and ADC values decreased during follow up, however the difference was not statistically significant (p > 0.05). Both qualitative and quantitative MRI methods confirmed active inflammatory disease in the C-C region following therapy although all clinical criteria showed signs of improvement of the peripheral disease. Conclusions: The study proved the feasibility of DCEI and DWI MRI for quantifying synovitis of the C-C region in patients with early RA and neck pain. Both techniques can be used as additional method for evaluation of synovitis of the C-C region in RA.

  10. Quantification of synovitis in the cranio-cervical region: Dynamic contrast enhanced and diffusion weighted magnetic resonance imaging in early rheumatoid arthritis—A feasibility follow up study

    International Nuclear Information System (INIS)

    Jeromel, M.; Jevtič, V.; Serša, I.; Ambrožič, A.; Tomšič, M.

    2012-01-01

    Objective: To test the feasibility of dynamic contrast enhanced (DCEI) and diffusion weighted (DWI) magnetic resonance imaging (MRI) for quantifying synovitis of the cranio-cervical (C-C) region in patients with early rheumatoid arthritis (RA) and neck pain at the beginning and at a six month follow up. Methods: 27 patients with duration of RA of less than 24 months and neck pain were studied with standard qualitative MRI evaluation and two quantitative MRI methods (DCEI and DWI) at the level of atlantoaxial joints. Rate of early enhancement (REE), enhancement gradient (Genh) and apparent diffusion coefficient (ADC) were extracted from DCEI and DWI data. MRI was coupled with clinical assessment and radiographic imaging. Results: Using standard qualitative MRI evaluation, unequivocal active synovitis (grade 2 or 3 contrast enhancement) was proved in 16 (59%) patients at baseline and 14 (54%) at follow up. DCEI and DWI measurements confirmed active synovitis in 25 (93%) patients at baseline and 24 (92%) at follow up. Average REE, Genh and ADC values decreased during follow up, however the difference was not statistically significant (p > 0.05). Both qualitative and quantitative MRI methods confirmed active inflammatory disease in the C-C region following therapy although all clinical criteria showed signs of improvement of the peripheral disease. Conclusions: The study proved the feasibility of DCEI and DWI MRI for quantifying synovitis of the C-C region in patients with early RA and neck pain. Both techniques can be used as additional method for evaluation of synovitis of the C-C region in RA.

  11. VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver; VIBE mit paralleler Akquisitionstechnik - eine neue Moeglichkeit der dynamischen kontrastverstaerkten MRT der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Dobritz, M.; Radkow, T.; Bautz, W.; Fellner, F.A. [Inst. fuer Diagnostische Radiologie, Friedrich-Alexander-Univ. Erlangen-Nuernberg (Germany); Nittka, M. [Siemens Medical Solutions, Erlangen (Germany)

    2002-06-01

    Purpose: The VIBE (volume interpolated breath-hold examination) sequence in combination with parallel acquisition technique (iPAT: integrated parallel acquisition technique) allows dynamic contrast-enhanced MRI of the liver with high temporal and spatial resolution. The aim of this study was to obtain first clinical experience with this technique for the detection and characterization of focal liver lesions. Materials and Methods: We examined 10 consecutive patients using a 1.5 T MR system (gradient field strength 30 mT/m) with a phased-array coil combination. Following sequences- were acquired: T{sub 2}-w TSE and T{sub 1}-w FLASH, after administration of gadolinium, 6 VIBE sequences with iPAT (TR/TE/matrix/partition thickness/time of acquisition: 6.2 ms/ 3.2 ms/256 x 192/4 mm/13 s), as well as T{sub 1}-weighted FLASH with fat saturation. Two observers evaluated the different sequences concerning the number of lesions and their dignity. Following lesions were found: hepatocellular carcinoma (5 patients), hemangioma (2), metastasis (1), cyst (1), adenoma (1). Results: The VIBE sequences were superior for the detection of lesions with arterial hyperperfusion with a total of 33 focal lesions. 21 lesions were found with T{sub 2}-w TSE and 20 with plain T{sub 1}-weighted FLASH. Diagnostic accuracy increased with the VIBE sequence in comparison to the other sequences. Conclusion: VIBE with iPAT allows MR imaging of the liver with high spatial and temporal resolution providing dynamic contrast-enhanced information about the whole liver. This may lead to improved detection of liver lesions, especially hepatocellular carcinoma. (orig.) [German] Ziel: Die VIBE-Sequenz (Volume Interpolated Breath-hold Examination) in Kombination mit paralleler Bildgebung (iPAT) ermoeglicht eine dynamische kontrastmittel-gestuetzte Untersuchung der Leber in hoher zeitlicher und oertlicher Aufloesung. Ziel war es, erste klinische Erfahrungen mit dieser Technik in der Detektion fokaler

  12. Neural - levelset shape detection segmentation of brain tumors in dynamic susceptibility contrast enhanced and diffusion weighted magnetic resonance images

    International Nuclear Information System (INIS)

    Vijayakumar, C.; Bhargava, Sunil; Gharpure, Damayanti Chandrashekhar

    2008-01-01

    A novel Neuro - level set shape detection algorithm is proposed and evaluated for segmentation and grading of brain tumours. The algorithm evaluates vascular and cellular information provided by dynamic contrast susceptibility magnetic resonance images and apparent diffusion coefficient maps. The proposed neural shape detection algorithm is based on the levels at algorithm (shape detection algorithm) and utilizes a neural block to provide the speed image for the level set methods. In this study, two different architectures of level set method have been implemented and their results are compared. The results show that the proposed Neuro-shape detection performs better in differentiating the tumor, edema, necrosis in reconstructed images of perfusion and diffusion weighted magnetic resonance images. (author)

  13. Molecular Imaging of Tumors Using a Quantitative T1 Mapping Technique via Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Kelsey Herrmann

    2015-07-01

    Full Text Available Magnetic resonance imaging (MRI of glioblastoma multiforme (GBM with molecular imaging agents would allow for the specific localization of brain tumors. Prior studies using T1-weighted MR imaging demonstrated that the SBK2-Tris-(Gd-DOTA3 molecular imaging agent labeled heterotopic xenograft models of brain tumors more intensely than non-specific contrast agents using conventional T1-weighted imaging techniques. In this study, we used a dynamic quantitative T1 mapping strategy to more objectively compare intra-tumoral retention of the SBK2-Tris-(Gd-DOTA3 agent over time in comparison to non-targeted control agents. Our results demonstrate that the targeted SBK2-Tris-(Gd-DOTA3 agent, a scrambled-Tris-(Gd-DOTA3 control agent, and the non-specific clinical contrast agent Optimark™ all enhanced flank tumors of human glioma cells with similar maximal changes on T1 mapping. However, the retention of the agents differs. The non-specific agents show significant recovery within 20 min by an increase in T1 while the specific agent SBK2-Tris-(Gd-DOTA3 is retained in the tumors and shows little recovery over 60 min. The retention effect is demonstrated by percent change in T1 values and slope calculations as well as by calculations of gadolinium concentration in tumor compared to muscle. Quantitative T1 mapping demonstrates the superior binding and retention in tumors of the SBK2-Tris-(Gd-DOTA3 agent over time compared to the non-specific contrast agent currently in clinical use.

  14. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  15. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  16. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  17. Assessment of dynamic contrast-enhanced magnetic resonance imaging in the differentiation of malignant from benign orbital masses

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Ying [Department of Radiology, Shanghai Ninth People' s Hospital, Affiliated to JiaoTong University School of Medicine, Shanghai 200011 (China); Kuai, Xin-Ping [Department of Radiology, Changshu Second People' s Hospital, Jiangsu Province 215500 (China); Department of Radiology, Changzheng Hospital, Affiliated to Second Military Medical University, Shanghai 200003 (China); Chen, Xiao-Song [Comprehensive Breast Health Center, Ruijin Hospital Shanghai Jiaotong University School of Medicine, 197 Ruijin Er Road, Shanghai 20025 (China); Tao, Xiao-Feng, E-mail: cjr.taoxiaofeng@vip.163.com [Department of Radiology, Shanghai Ninth People' s Hospital, Affiliated to JiaoTong University School of Medicine, Shanghai 200011 (China)

    2013-09-15

    Objective: Dynamic contrast enhanced MR imaging (DCE-MRI) allows imaging of the physiology of the microcirculation. The purpose of this study was to determine the diagnostic efficacy of time intensity curve (TIC) and DCE parameters for characterization of orbital masses. Methods: Fifty-nine patients with untreated orbital lesions underwent DCE-MRI before surgery. For each lesion, peak height (PH), maximum enhancement ratio (ER{sub max}), time of peak enhancement (T{sub peak}) and maximum rise slope (Slope{sub max}) were plotted and calculated. Receiver operator characteristics (ROC) analysis was conducted to assess the appropriate cut-off value. Results: All 26 lesions that demonstrated persistent pattern (type-I) TICs were benign. Most of the masses with the washout pattern (type-III) TIC were malignant (10/14), including lymphoma (n = 6) and melanoma (n = 4). The Slope{sub max} of benign lesions was statistically lower than malignant ones, while the ER{sub max} and T{sub peak} values of benign lesions were significantly higher. No statistical difference was found in PH (P = 0.121). The AUC for ER{sub max}, T{sub peak} and Slope{sub max} in differentiating benign orbital lesions from malignant ones were 0.683, 0.837 and 0.738, respectively. In the three DCE parameters, Slope{sub max} cut-off value of 1.10 provided the highest sensitivity of 93.8%; however, the corresponding specificity was low (58.1%). The ER{sub max} cut-off value of 1.37 and T{sub peak} cut-off value of 35.14 respectively offered the best diagnostic performances. Conclusion: DCE-MRI, especially the qualitative TIC pattern and quantitative value of Slope{sub max}, ER{sub max} and T{sub peak}, could be a complementary investigation in distinguishing malignant orbital tumor from benign ones.

  18. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  19. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  20. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results.

    Science.gov (United States)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R; Scheenen, Tom W; Bathen, Tone F; Selnæs, Kirsten M

    2017-07-01

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K trans and V e ) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p textural features correlated insignificantly with K trans and V e . GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K trans , and V e . The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. • T2W MRI-derived textural features correlate significantly with Gleason score and ADC. • T2W MRI-derived textural features differentiate Gleason score 3+4 from 4+3 cancers. • T2W image textural features could augment tumour characterization.

  1. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Vos, Frans M.

    2017-01-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal

  2. The Steroid Effect on the Blood-Ocular Barrier Change Induced by Triolein Emulsion as seen on Contrast-Enhanced MR Images

    International Nuclear Information System (INIS)

    Lee, Jong Yuk; Eun, Choong Ki; Kim, Yong Woo; Kim, Hak Jin; Jung, Yeon Joo; Jae, Seung Youn; Cho, Byung Mann; Choi, Seon Hee

    2008-01-01

    The purpose of this study is to evaluate the effect of dexamethasone on the damaged blood-ocular barrier caused by triolein emulsion, using contrast-enhanced MR imaging. An emulsion of 0.1-mL triolein in 20 mL of saline was infused into the carotid arteries of 32 cats, 12 cats were placed in the treatment group and 18 cats were placed in the Control group. Thirty minutes after the infusion of triolein emulsion, a set of orbital pre- and post-contrast T1-weighted MR images (T1WIs) were obtained. Infusion of 10 mg/kg dexamethasone into the ipsilateral carotid artery of each of the cats in the treatment group cats and 20 mL saline in each of the cats in the control group was given. A second set of pre- and post-contrast orbital T1WIs were obtained three hours following triolein emulsion infusion. Qualitative analysis was performed for the the anterior chamber (AC), the posterior chamber (PC), and in the vitreous humor of the ipsilateral and contralateral eyes. The signal intensity ratios of the ipsilateral eye over the contralateral eye were quantitatively evaluated in the three ocular chambers on the first and second set of T1WIs, and were then statistically compared. Qualitatively, the AC, the PC or the vitreous did not show immediate contrast enhancement on the first and the second set of post-contrast T1WIs. However, the AC and the PC showed delayed contrast enhancement for both groups of cats on the second pre-contrast T1WIs. No enhancement or minimally delayed enhancement was seen for the vitreous humor. Quantitatively, the signal intensity ratios in the PC of the treatment group of cats were statistically lower than the ratios of the control group of cats for the second set of T1WIs (p = 0.037). The AC and vitreous showed no statistically significant difference between the feline treatment group and control group (p > 0.05). Contrast-enhanced MR images revealed increased vascular permeability in the PC of the eye after infusion of triolein emulsion

  3. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    International Nuclear Information System (INIS)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard; Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre; Burkholder, Iris

    2014-01-01

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K trans , K ep , iAUC and V e were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K trans , K ep and V e within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  4. Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images.

    Science.gov (United States)

    Seuss, Hannes; Janka, Rolf; Prümmer, Marcus; Cavallaro, Alexander; Hammon, Rebecca; Theis, Ragnar; Sandmair, Martin; Amann, Kerstin; Bäuerle, Tobias; Uder, Michael; Hammon, Matthias

    2017-04-01

    Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.

  5. Evaluation of renal vascular in living donors before transplantation using dynamic contrast enhanced MR angiography

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Zhong Xin; Dong Yuru; Dong Yue; Ma Yi; Wu Chunnan

    2010-01-01

    Objective: To explore whether dynamic contrast-enhanced MRA (DCE MRA) can provide an effective assessment of renal vascular in living donors before transplantation. Methods: Thirty five healthy living renal donor candidates were scanned on MR system before transplantation. After injection of Gd-DTPA 1 ml in vein, a test-bolus scan was used to get the time delay of Gd-DTPA reaching renal artery. Then, a 3D T 1 -weighted fast low-angle shot sequence (3D FLASH) was performed in the coronal plane. The 3D FLASH scan would repeat four times with an inter-phase of 10 seconds. Thus, the imaging of the renal arterial, venous and collecting systems were got. Two radiologists observed renal arteries and veins on original imaging and MIP reconstmcted imaging. The quality of MR angiography was evaluated on a five- point scale and the vascular anatomy or variations of the arterial and venous systems were recorded, using intraoperative findings as a standard of reference. Results: The quality for all MRA was good or very good for the most of living renal donors. Among 70 renals, several variations of vascular were found, including 5 left accessory artery, 9 right accessory artery, 3 left proximal arterial branch and 6 right proximal arterial branch. Among 70 renal veins, 1 right accessory veins and 2 left varicocele were observed. One small accessory artery of right kidney was missed with DCE MRA, but identified by operation. Conclusion: DCE MRA was noninvasive tool for evaluation of the renal vasculature and variations with high accuracy. It would be a good modality in preoperative evaluation of living renal donors. (authors)

  6. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) of cadaveric shoulders: comparison of contrast dynamics in hyaline and fibrous cartilage after intraarticular gadolinium injection.

    Science.gov (United States)

    Wiener, E; Hodler, J; Pfirrmann, C W A

    2009-01-01

    Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) is a novel method to investigate cartilaginous and fibrocartilaginous structures. To investigate the contrast dynamics in hyaline and fibrous cartilage of the glenohumeral joint after intraarticular injection of gadopentetate dimeglumine. Transverse T(1) maps were acquired on a 1.5T scanner before and after intraarticular injection of 2.0 mmol/l gadopentetate dimeglumine in five cadaveric shoulders using a dual flip angle three-dimensional gradient echo (3D-GRE) sequence. The acquisition time for the T(1) maps was 5 min 5 s for the whole shoulder. Measurements were repeated every 15 min over 2.5 hours. Regions of interest (ROIs) covering the glenoid cartilage and the labrum were drawn to assess the temporal evolution of the relaxation parameters. T(1) of unenhanced hyaline cartilage of the glenoid was 568+/-34 ms. T(1) of unenhanced fibrous cartilage of the labrum was 552+/-38 ms. Significant differences (P=0.002 and 0.03) in the relaxation parameters were already measurable after 15 min. After 2 to 2.5 hours, hyaline and fibrous cartilage still demonstrated decreasing relaxation parameters, with a larger range of the T(1)(Gd) values in fibrous cartilage. T(1) and triangle Delta R(1) values of hyaline and fibrous cartilage after 2.5 hours were 351+/-16 ms and 1.1+/-0.09 s(-1), and 332+/-31 ms and 1.2+/-0.1 s(-1), respectively. A significant decrease in T(1)(Gd) was found 15 min after intraarticular contrast injection. Contrast accumulation was faster in hyaline than in fibrous cartilage. After 2.5 hours, contrast accumulation showed a higher rate of decrease in hyaline cartilage, but neither hyaline nor fibrous cartilage had reached equilibrium.

  7. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Service de Radiologie, Hopital Tenon, Paris (France); Balvay, Daniel [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Aubert, Emilie; Bazot, Marc [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Darai, Emile; Rouzier, Roman [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Gynaecology-Obstetrics, Paris (France); Cuenod, Charles A. [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Department of Radiology, Paris (France)

    2012-04-15

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F{sub T}), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F{sub T}, Vb, rAUC and lower Ve than benign tumours (P < 0.0001, P = 0.0006, P = 0.04 and P = 0.0002, respectively). F{sub T} was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F{sub T} and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  8. Recent advances in contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Meaney, J.F.M.; Goyen, M.

    2007-01-01

    Magnetic resonance angiography (MRA) provides a means of visualizing vascular structures noninvasively and is increasingly replacing conventional X-ray angiography in routine use. Contrast-enhanced MRA (CE-MRA), in which gadolinium contrast agents are used to shorten the T1 relaxation, offers increased resolution and higher signal-to-noise ratio compared with earlier flow-dependent [time-of-flight (TOF) or phase-contrast (PC)] techniques. Currently available contrast agents differ in their ability to lower T1 values, and hence the choice of contrast agent is an important consideration in the successful use of CE-MRA. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first of a new class of intravascular contrast agents. This agent is extensively (approximately 85%) and reversibly bound to human serum albumin and is retained within the vasculature thus allowing steady-state imaging to be perform-ed. An additional benefit is that gado0fosveset offers higher relaxivity compared with other contrast agents, thus giving a lower blood T1 values which also makes it ideal for first-pass imaging. Clinical trials have consistently shown that gadofosveset enhanced MRA is more sensitive, specific and accurate than time-of-flight MRA, gives fewer uninterpretable scans and affords greater diagnostic confidence. Intravascular contrast agents such as gadofosveset, therefore, offer the potential for improved vascular imaging. (orig.)

  9. A novel nitroreductase-enhanced MRI contrast agent and its potential application in bacterial imaging

    Directory of Open Access Journals (Sweden)

    Yun Liu

    2018-05-01

    Full Text Available Nitroreductases (NTRs are known to be able to metabolize nitro-substituted compounds in the presence of reduced nicotinamide adenine dinucleotide (NADH as an electron donor. NTRs are present in a wide range of bacterial genera and, to a lesser extent, in eukaryotes hypoxic tumour cells and tumorous tissues, which makes it an appropriate biomarker for an imaging target to detect the hypoxic status of cancer cells and potential bacterial infections. To evaluate the specific activation level of NTR, great efforts have been devoted to the development of fluorescent probes to detect NTR activities using fluorogenic methods to probe its behaviour in a cellular context; however, NTR-responsive MRI contrast agents are still by far underexplored. In this study, para-nitrobenzyl substituted T1-weighted magnetic resonance imaging (MRI contrast agent Gd-DOTA-PNB (probe 1 has been designed and explored for the possible detection of NTR. Our experimental results show that probe 1 could serve as an MRI-enhanced contrast agent for monitoring NTR activity. The in vitro response and mechanism of the NTR catalysed reduction of probe 1 have been investigated through LC–MS and MRI. Para-nitrobenzyl substituted probe 1 was catalytically reduced by NTR to the intermediate para-aminobenzyl substituted probe which then underwent a rearrangement elimination reaction to Gd-DOTA, generating the enhanced T1-weighted MR imaging. Further, LC–MS and MRI studies of living Escherichia coli have confirmed the NTR activity detection ability of probe 1 at a cellular level. This method may potentially be used for the diagnosis of bacterial infections. KEY WORDS: Nitroreductase, MRI contrast agent, Smart imaging probes, Bacterial imaging, Bacterial infection

  10. Transcriptomic characterization of MRI contrast with focus on the T1-w/T2-w ratio in the cerebral cortex.

    Science.gov (United States)

    Ritchie, Jacob; Pantazatos, Spiro P; French, Leon

    2018-07-01

    Magnetic resonance (MR) images of the brain are of immense clinical and research utility. At the atomic and subatomic levels, the sources of MR signals are well understood. However, we lack a comprehensive understanding of the macromolecular correlates of MR signal contrast. To address this gap, we used genome-wide measurements to correlate gene expression with MR signal intensity across the cerebral cortex in the Allen Human Brain Atlas (AHBA). We focused on the ratio of T1-weighted and T2-weighted intensities (T1-w/T2-w ratio image), which is considered to be a useful proxy for myelin content. As expected, we found enrichment of positive correlations between myelin-associated genes and the ratio image, supporting its use as a myelin marker. Genome-wide, there was an association with protein mass, with genes coding for heavier proteins expressed in regions with high T1-w/T2-w values. Oligodendrocyte gene markers were strongly correlated with the T1-w/T2-w ratio, but this was not driven by myelin-associated genes. Mitochondrial genes exhibit the strongest relationship, showing higher expression in regions with low T1-w/T2-w ratio. This may be due to the pH gradient in mitochondria as genes up-regulated by pH in the brain were also highly correlated with the ratio. While we corroborate associations with myelin and synaptic plasticity, differences in the T1-w/T2-w ratio across the cortex are more strongly linked to molecule size, oligodendrocyte markers, mitochondria, and pH. We evaluate correlations between AHBA transcriptomic measurements and a group averaged T1-w/T2-w ratio image, showing agreement with in-sample results. Expanding our analysis to the whole brain results in strong positive T1-w/T2-w correlations for immune system, inflammatory disease, and microglia marker genes. Genes with negative correlations were enriched for neuron markers and synaptic plasticity genes. Lastly, our findings are similar when performed on T1-w or inverted T2-w intensities alone

  11. T2-weighted images are superior to other MR image types for the determination of diffuse intrinsic pontine glioma intratumoral heterogeneity.

    Science.gov (United States)

    Harward, Stephen; Harrison Farber, S; Malinzak, Michael; Becher, Oren; Thompson, Eric M

    2018-03-01

    Diffuse intrinsic pontine glioma (DIPG) remains the main cause of death in children with brain tumors. Given the inefficacy of numerous peripherally delivered agents to treat DIPG, convection enhanced delivery (CED) of therapeutic agents is a promising treatment modality. The purpose of this study was to determine which MR imaging type provides the best discrimination of intratumoral heterogeneity to guide future stereotactic implantation of CED catheters into the most cellular tumor regions. Patients ages 18 years or younger with a diagnosis of DIPG from 2000 to 2015 were included. Radiographic heterogeneity index (HI) of the tumor was calculated by measuring the standard deviation of signal intensity of the tumor (SD Tumor ) normalized to the genu of the corpus callosum (SD Corpus Callosum ). Four MR image types (T2-weighted, contrast-enhanced T1-weighted, FLAIR, and ADC) were analyzed at several time points both before and after radiotherapy and chemotherapy. HI values across these MR image types were compared and correlated with patient survival. MR images from 18 patients with DIPG were evaluated. The mean survival ± standard deviation was 13.8 ± 13.7 months. T2-weighted images had the highest HI (mean ± SD, 5.1 ± 2.5) followed by contrast-enhanced T1-weighted images (3.7 ± 1.5), FLAIR images (3.0 ± 1.1), and ADC maps (1.6 ± 0.4). ANOVA demonstrated that HI values were significantly higher for T2-weighted images than FLAIR (p image HI values increased, while FLAIR and ADC HI values decreased. Univariate and multivariate analyses did not reveal a relationship between HI values and patient survival (p > 0.05). For children with DIPG, T2-weighted MRI demonstrates the greatest signal intensity variance suggesting tumor heterogeneity. Within this heterogeneity, T2-weighted signal hypointensity is known to correlate with increased cellularity and thus may represent a putative target for CED catheter placement in future clinical

  12. Assessment of Myocardial Fibrosis in Mice Using a T2*-Weighted 3D Radial Magnetic Resonance Imaging Sequence.

    Directory of Open Access Journals (Sweden)

    Bastiaan J van Nierop

    Full Text Available Myocardial fibrosis is a common hallmark of many diseases of the heart. Late gadolinium enhanced MRI is a powerful tool to image replacement fibrosis after myocardial infarction (MI. Interstitial fibrosis can be assessed indirectly from an extracellular volume fraction measurement using contrast-enhanced T1 mapping. Detection of short T2* species resulting from fibrotic tissue may provide an attractive non-contrast-enhanced alternative to directly visualize the presence of both replacement and interstitial fibrosis.To goal of this paper was to explore the use of a T2*-weighted radial sequence for the visualization of fibrosis in mouse heart.C57BL/6 mice were studied with MI (n = 20, replacement fibrosis, transverse aortic constriction (TAC (n = 18, diffuse fibrosis, and as control (n = 10. 3D center-out radial T2*-weighted images with varying TE were acquired in vivo and ex vivo (TE = 21 μs-4 ms. Ex vivo T2*-weighted signal decay with TE was analyzed using a 3-component model. Subtraction of short- and long-TE images was used to highlight fibrotic tissue with short T2*. The presence of fibrosis was validated using histology and correlated to MRI findings.Detailed ex vivo T2*-weighted signal analysis revealed a fast (T2*fast, slow (T2*slow and lipid (T2*lipid pool. T2*fast remained essentially constant. Infarct T2*slow decreased significantly, while a moderate decrease was observed in remote tissue in post-MI hearts and in TAC hearts. T2*slow correlated with the presence of diffuse fibrosis in TAC hearts (r = 0.82, P = 0.01. Ex vivo and in vivo subtraction images depicted a positive contrast in the infarct co-localizing with the scar. Infarct volumes from histology and subtraction images linearly correlated (r = 0.94, P<0.001. Region-of-interest analysis in the in vivo post-MI and TAC hearts revealed significant T2* shortening due to fibrosis, in agreement with the ex vivo results. However, in vivo contrast on subtraction images was rather poor

  13. Delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) of Cadaveric Shoulders: Comparison of Contrast Dynamics in Hyaline and Fibrous Cartilage after Intraarticular Gadolinium Injection

    Energy Technology Data Exchange (ETDEWEB)

    Wiener, E. (Dept. of Radiology, Charite Universitaetsmedizin Berlin (Germany)); Hodler, J.; Pfirrmann, C.W.A. (Dept. of Radiology, Orthopedic Univ. Hospital Balgrist, Zuerich (Switzerland))

    2009-01-15

    Background: Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) is a novel method to investigate cartilaginous and fibrocartilaginous structures. Purpose: To investigate the contrast dynamics in hyaline and fibrous cartilage of the glenohumeral joint after intraarticular injection of gadopentetate dimeglumine. Material and Methods: Transverse T1 maps were acquired on a 1.5T scanner before and after intraarticular injection of 2.0 mmol/l gadopentetate dimeglumine in five cadaveric shoulders using a dual flip angle three-dimensional gradient echo (3D-GRE) sequence. The acquisition time for the T1 maps was 5 min 5 s for the whole shoulder. Measurements were repeated every 15 min over 2.5 hours. Regions of interest (ROIs) covering the glenoid cartilage and the labrum were drawn to assess the temporal evolution of the relaxation parameters. Results: T1 of unenhanced hyaline cartilage of the glenoid was 568+-34 ms. T1 of unenhanced fibrous cartilage of the labrum was 552+-38 ms. Significant differences (P=0.002 and 0.03) in the relaxation parameters were already measurable after 15 min. After 2 to 2.5 hours, hyaline and fibrous cartilage still demonstrated decreasing relaxation parameters, with a larger range of the T1(Gd) values in fibrous cartilage. T1 and ?R1 values of hyaline and fibrous cartilage after 2.5 hours were 351+-16 ms and 1.1+-0.09/s, and 332+-31 ms and 1.2+-0.1/s, respectively. Conclusion: A significant decrease in T1(Gd) was found 15 min after intraarticular contrast injection. Contrast accumulation was faster in hyaline than in fibrous cartilage. After 2.5 hours, contrast accumulation showed a higher rate of decrease in hyaline cartilage, but neither hyaline nor fibrous cartilage had reached equilibrium

  14. Application of fast spin-echo T2-weighted imaging for examination of the neurocranium. Comparison with the conventional T2-weighted spin-echo sequence

    International Nuclear Information System (INIS)

    Siewert, C.; Hosten, N.; Felix, R.

    1994-01-01

    T 2 -weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T 2 -weighted imaging (TT 2 ) of the neurocranium in comparison to conventional spin-echo T 2 -weighted imaging (T 2 ). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT 2 than in T 2 (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT 2 , Parkinson patients have to be examined by conventional T 2 . If these limitations are taken into account, fast spin-echo T 2 -weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T 2 -weighting achieved in a short acquisition time. (orig.) [de

  15. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1993-03-15

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding.

  16. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    International Nuclear Information System (INIS)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo

    1993-01-01

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding

  17. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging

    International Nuclear Information System (INIS)

    Fujii, Shinya; Kido, Aki; Baba, Tsukasa; Fujimoto, Koji; Daido, Sayaka; Matsumura, Noriomi; Konishi, Ikuo; Togashi, Kaori

    2015-01-01

    Highlights: •We have assessed the peritumoral enhancement (PTE), which mimics SEE on DCE. •We evaluated the diagnostic accuracy of SEE for the myometrial invasion and the frequency of PTE. •We assessed the relationship between these enhancements and important pathologic factors. •PTE Type 1 is the main factor causing the overestimation of myometrial invasion using SEE on DCE. •PTE Type 2 correlates the myometrial invasion and may play an important role in the diagnosis of LVSI. -- Abstract: Objectives: To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. Materials and methods: MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. Results: The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1–46.4%, 85.8–88.5%, 69.2–76.5%, and 84.4–87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p < 0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p < 0.05) and depth (p < 0.01). Conclusion: Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the

  18. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, Yonago (Japan); Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Kido, Aki, E-mail: akikido@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Baba, Tsukasa [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Fujimoto, Koji; Daido, Sayaka [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Matsumura, Noriomi; Konishi, Ikuo [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan)

    2015-04-15

    Highlights: •We have assessed the peritumoral enhancement (PTE), which mimics SEE on DCE. •We evaluated the diagnostic accuracy of SEE for the myometrial invasion and the frequency of PTE. •We assessed the relationship between these enhancements and important pathologic factors. •PTE Type 1 is the main factor causing the overestimation of myometrial invasion using SEE on DCE. •PTE Type 2 correlates the myometrial invasion and may play an important role in the diagnosis of LVSI. -- Abstract: Objectives: To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. Materials and methods: MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. Results: The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1–46.4%, 85.8–88.5%, 69.2–76.5%, and 84.4–87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p < 0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p < 0.05) and depth (p < 0.01). Conclusion: Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the

  19. Hemophilic arthropathy of the knee joint: static and dynamic Gd-DTPA - enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. [Dept. of Radiology, Univ. Bonn (Germany); Bruening, R. [Dept. of Radiology, Univ. Muenchen (Germany); Kunze, V. [Dept. of Radiology, Univ. Bonn (Germany); Eickhoff, H. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Koch, W. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Reiser, M. [Dept. of Radiology, Univ. Muenchen (Germany)

    1995-12-31

    A total of 17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRI before and after an IV bolus injection of Gadolinium-DTPA (Gd-DTPA; 0.1 mmol/kg body weight). The T1-weighted spin-echo (SE) and gradient-echo (fast-field echo [FFE]) sequences were applied. The FFE sequences of eight consecutive scans carried out over a time interval of 160 s were used in order to determine the time to signal intensity (SI) curves of the synovial proliferations surrounding soft tissue, bone marrow, and joint effusion. After the administration of a contrast agent, synovial proliferations exhibited an increase on FFE and SE images of 47.7% (SD {+-} 14.3%) and 37.4% (SD {+-} 11.2%), respectively, whereas muscle and fatty tissue, tendons, bone marrow, and joint effusion revealed only a minor increase in SI. The gradient of SI (ratio SI/time) of pannus was 39.6%/min (SD {+-} 7.7%/min) and differed significantly (P < 0.001) from that of bone marrow, fatty tissue, muscle tissue, tendons, and joint effusion (P < 0.05). In contrast to synovial proliferations in rheumatoid arthritis, no differentiation between various pannus vascularities based on the degree of enhancement was possible. The Gd-DTPA-enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.)

  20. Hemophilic arthropathy of the knee joint: static and dynamic Gd-DTPA -enhanced MRI

    International Nuclear Information System (INIS)

    Naegele, M.; Bruening, R.; Kunze, V.; Eickhoff, H.; Koch, W.; Reiser, M.

    1995-01-01

    A total of 17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRI before and after an IV bolus injection of Gadolinium-DTPA (Gd-DTPA; 0.1 mmol/kg body weight). The T1-weighted spin-echo (SE) and gradient-echo (fast-field echo [FFE]) sequences were applied. The FFE sequences of eight consecutive scans carried out over a time interval of 160 s were used in order to determine the time to signal intensity (SI) curves of the synovial proliferations surrounding soft tissue, bone marrow, and joint effusion. After the administration of a contrast agent, synovial proliferations exhibited an increase on FFE and SE images of 47.7% (SD ± 14.3%) and 37.4% (SD ± 11.2%), respectively, whereas muscle and fatty tissue, tendons, bone marrow, and joint effusion revealed only a minor increase in SI. The gradient of SI (ratio SI/time) of pannus was 39.6%/min (SD ± 7.7%/min) and differed significantly (P < 0.001) from that of bone marrow, fatty tissue, muscle tissue, tendons, and joint effusion (P < 0.05). In contrast to synovial proliferations in rheumatoid arthritis, no differentiation between various pannus vascularities based on the degree of enhancement was possible. The Gd-DTPA-enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.)

  1. Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T

    International Nuclear Information System (INIS)

    Attenberger, Ulrike I.; Wintersperger, Bernd J.; Sourbron, Steven P.; Reiser, Maximilian F.; Michaely, Henrik J.; Schoenberg, Stefan O.; Lodemann, Klaus-Peter

    2008-01-01

    The purpose was to evaluate the image quality of high-spatial resolution MRA of the renal arteries at 1.5 T after contrast-agent injection of 0.2 mmol/kg body weight (BW) in an interindividual comparison to 3.0 T after contrast-agent injection of 0.1 mmol/kg BW contrast agent (CA). After IRB approval and informed consent, 40 consecutive patients (25 men, 15 women; mean age 53.9 years) underwent MRA of the renal arteries either at a 1.5-T MR system with 0.2 mmol/kg BW gadobutrol or at a 3.0-T MR scanner with 0.1 mmol/kg BW gadobenate dimeglumine used as CA in a randomized order. A constant volume of 15 ml of these contrast agents was applied. The spatial resolution of the MRA sequences was 1.0 x 0.8 x 1.0 mm 3 at 1.5 T and 0.9 x 0.8 x 0.9 mm 3 at 3.0 T, which was achieved by using parallel imaging acceleration factors of 2 at 1.5 T and 3 at 3.0 T, respectively. Two radiologists blinded to the administered CA and the field strength assessed the image quality and the venous overlay for the aorta, the proximal and distal renal arteries independently on a four-point Likert-type scale. Phantom measurements were performed for a standardized comparison of SNR at 1.5 T and 3.0 T. There was no significant difference (p > 0.05) between the image quality at 3.0 T with 0.1 mmol/kg BW gadobenate dimeglumine compared to the exams at 1.5 T with 0.2 mmol/kg BW gadobutrol. The median scores were between 3 and 4 (good to excellent vessel visualization) for the aorta (3 at 1.5 T/4 at 3.0 T for reader 1 and 2). For the proximal renal arteries, median scores were 3 for the left and right renal artery at 1.5 T for both readers. At 3.0 T, median scores were 3 (left proximal renal artery) and 4 (right proximal renal artery) for reader 1 and 3 (left/right) for reader 2 at 3.0 T. For the distal renal arteries, median scores were between 2 and 3 at both field strengths (moderate and good) for both readers. The κ values for both field strengths were comparable and ranged between 0

  2. Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, Ulrike I.; Wintersperger, Bernd J.; Sourbron, Steven P.; Reiser, Maximilian F. [University Hospitals-Grosshadern, Ludwig-Maximilians-University Munich, Institute of Clinical Radiology, Munich (Germany); Michaely, Henrik J.; Schoenberg, Stefan O. [University Hospital Mannheim, University of Heidelberg, Institute of Clinical Radiology, Mannheim (Germany); Lodemann, Klaus-Peter [Bracco-Altana Pharma, Konstanz (Germany)

    2008-06-15

    The purpose was to evaluate the image quality of high-spatial resolution MRA of the renal arteries at 1.5 T after contrast-agent injection of 0.2 mmol/kg body weight (BW) in an interindividual comparison to 3.0 T after contrast-agent injection of 0.1 mmol/kg BW contrast agent (CA). After IRB approval and informed consent, 40 consecutive patients (25 men, 15 women; mean age 53.9 years) underwent MRA of the renal arteries either at a 1.5-T MR system with 0.2 mmol/kg BW gadobutrol or at a 3.0-T MR scanner with 0.1 mmol/kg BW gadobenate dimeglumine used as CA in a randomized order. A constant volume of 15 ml of these contrast agents was applied. The spatial resolution of the MRA sequences was 1.0 x 0.8 x 1.0 mm{sup 3} at 1.5 T and 0.9 x 0.8 x 0.9 mm{sup 3} at 3.0 T, which was achieved by using parallel imaging acceleration factors of 2 at 1.5 T and 3 at 3.0 T, respectively. Two radiologists blinded to the administered CA and the field strength assessed the image quality and the venous overlay for the aorta, the proximal and distal renal arteries independently on a four-point Likert-type scale. Phantom measurements were performed for a standardized comparison of SNR at 1.5 T and 3.0 T. There was no significant difference (p > 0.05) between the image quality at 3.0 T with 0.1 mmol/kg BW gadobenate dimeglumine compared to the exams at 1.5 T with 0.2 mmol/kg BW gadobutrol. The median scores were between 3 and 4 (good to excellent vessel visualization) for the aorta (3 at 1.5 T/4 at 3.0 T for reader 1 and 2). For the proximal renal arteries, median scores were 3 for the left and right renal artery at 1.5 T for both readers. At 3.0 T, median scores were 3 (left proximal renal artery) and 4 (right proximal renal artery) for reader 1 and 3 (left/right) for reader 2 at 3.0 T. For the distal renal arteries, median scores were between 2 and 3 at both field strengths (moderate and good) for both readers. The {kappa} values for both field strengths were comparable and ranged

  3. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    Science.gov (United States)

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (PCHESS sequence and the 3D FSE T1-weighted CHESS sequence (PCHESS sequence (PCHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (PCHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  4. Influence of field strength, coil type and image resolution on assessment of synovitis by unenhanced MRI--a comparison with contrast-enhanced MRI

    DEFF Research Database (Denmark)

    Eshed, Iris; Krabbe, Simon; Østergaard, Mikkel

    2015-01-01

    post-contrast T1-weighted sequence was used as gold standard reference. RESULTS: Fair-good agreement (ICC=0.38--0.72) between the standard reference and the different STIR protocols (best agreement with extremity coil and small voxel size at 1.5 T). The accuracy for presence/absence of synovitis...... is only moderately reliable for assessing hand synovitis in RA, when contrast-enhanced MRI is considered the gold standard reference. Contrast injection, field strength and coil type influence synovitis assessment, and should be considered before performing MRI in clinical trials and practice. KEY POINTS...

  5. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  6. Soft-tissue and bone lesions examined with 1.5-T MR imaging and Gd-DOTA

    International Nuclear Information System (INIS)

    VonSchulthess, G.K.; Kuoni, W.; Wuthrich, R.; Duewell, S.; Thurnher, S.; Marincek, B.

    1988-01-01

    Fifteen patients with soft-tissue masses or bone lesions underwent 16 MR imaging examinations with gadolinium-DOTA, a new MR contrast agent. T1- and T2-weighted precontrast sequences were obtained. The contrast agent was injected in a concentration of 0.1 mmol/kg without any untoward effects. After contrast examination, one or two T1-weighted sequences were obtained. Contrast medium application improved the distinction between lesion and edema in four of seven cases, between the lesion and central necrosis in seven of eight cases, and between the lesion, and the surrounding tissues in four of 12 cases. In eight of 12 cases, additional structures within the lesion were noted after Gd-DOTA enhancement. Of particular benefit was the use of contrast media to evaluate the vascularization of the lesion (in 12 of 14 cases)

  7. Self-organizing neural networks for automatic detection and classification of contrast-enhancing lesions in dynamic MR-mammography; Selbstorganisierende neuronale Netze zur automatischen Detektion und Klassifikation von Kontrast(mittel)-verstaerkten Laesionen in der dynamischen MR-Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Vomweg, T.W.; Teifke, A.; Kauczor, H.U.; Achenbach, T.; Rieker, O.; Schreiber, W.G.; Heitmann, K.R.; Beier, T.; Thelen, M. [Klinik und Poliklinik fuer Radiologie, Klinikum der Univ. Mainz (Germany)

    2005-05-01

    Purpose: Investigation and statistical evaluation of 'Self-Organizing Maps', a special type of neural networks in the field of artificial intelligence, classifying contrast enhancing lesions in dynamic MR-mammography. Material and Methods: 176 investigations with proven histology after core biopsy or operation were randomly divided into two groups. Several Self-Organizing Maps were trained by investigations of the first group to detect and classify contrast enhancing lesions in dynamic MR-mammography. Each single pixel's signal/time curve of all patients within the second group was analyzed by the Self-Organizing Maps. The likelihood of malignancy was visualized by color overlays on the MR-images. At last assessment of contrast-enhancing lesions by each different network was rated visually and evaluated statistically. Results: A well balanced neural network achieved a sensitivity of 90.5% and a specificity of 72.2% in predicting malignancy of 88 enhancing lesions. Detailed analysis of false-positive results revealed that every second fibroadenoma showed a 'typical malignant' signal/time curve without any chance to differentiate between fibroadenomas and malignant tissue regarding contrast enhancement alone; but this special group of lesions was represented by a well-defined area of the Self-Organizing Map. Discussion: Self-Organizing Maps are capable of classifying a dynamic signal/time curve as 'typical benign' or 'typical malignant'. Therefore, they can be used as second opinion. In view of the now known localization of fibroadenomas enhancing like malignant tumors at the Self-Organizing Map, these lesions could be passed to further analysis by additional post-processing elements (e.g., based on T2-weighted series or morphology analysis) in the future. (orig.)

  8. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Farina, Davide; Bodin, Christiane; Gandolfi, Silvia; De Gasperi, Werner; Borghesi, Andrea; Maroldi, Roberto

    2009-01-01

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  9. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Davide [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Bodin, Christiane [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Gandolfi, Silvia [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); De Gasperi, Werner [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Borghesi, Andrea; Maroldi, Roberto [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)

    2009-04-15

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  10. The usefulness of dynamic MR imaging for the evaluation of cervical cancer

    International Nuclear Information System (INIS)

    Yoon, Jeong Hee; Park, Yeong Mi

    2004-01-01

    We wished to evaluate the diagnostic usefulness of dynamic MRI in assessing tumor visualization and the parametrial invasion of cervical cancer, and we also wished to determine the most adequate enhancing time by comparing the T2-weighted image (T2WI) and enhanced T1-weighted image (Gd-T1WI). Fifty-three women with histopathologically proven cervical cancer underwent a preoperative MRI. Using a 1.5 T magnet, the fast spin echo axial T2WI without fat saturation was taken; after contrast administration, 20, 40, 60, 90, 120 sec-dynamic MRIs were taken using fast SPGR and spin echo axial Gd-T1WI. Tumor conspicuity and parametrial invasion in each pulse sequence and the most adequate enhancing time for the evaluation of the tumor on dynamic MRI were evaluated prospectively by three radiologists working at three separate sessions. The results were then correlated with the histopathologic findings. The conspicuity of tumor on dynamic MRI (99.4%) and T2WI (95.6%) were better than on Gd-T1WI (89.3%). In the assessment of parametrial invasion of the tumor, the diagnostic accuracy of dynamic MRI, Gd-T1WI and T2WI was 79.9%, 78% and 76.1%, respectively; the highest values were for the dynamic MRI, but there was no statistically significant difference among three pulse sequences. The most adequate enhancing time on dynamic MRI was between 90 seconds and 120 seconds. Dynamic MRI is useful for the assessment of tumor visualization of cervical cancer, and the most appropriate scan time on dynamic MRI is between 90 seconds and 120 seconds. For the determination of parametrial invasion, the dynamic MRI revealed a higher diagnostic accuracy than that of T2WI or Gd-T1WI, but the differences were statistically insignificant

  11. Characteristics of hypertrophic cardiomyopathy on delayed contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Yan Chaowu; Zhao Shihua; Li Hua; Jiang Shiliang; Lu Minjie; Zhang Yan; Wei Yunqing; Ling Jian; Fang Wei

    2010-01-01

    Objective: To analyze the characteristics of hypertrophic cardiomyopathy (HCM) on delayed contrast-enhanced cardiac magnetic resonance imaging (CMRI). Methods: All patients underwent delayed contrast-enhanced CMRI. The left ventricle was divided into 9 segments to assess the location, extent and function of the hypertrophic segments. The t test was applied for the statistics. Results: Of 154 patients, delayed enhancement of' hypertrophic segment was found in 95 cases and non-delayed enhancement in 59 cases. The thickness and number of hypertrophic segment in patients with delayed enhancement were larger than those with non-delayed enhancement [(24.8±5.5) mm vs (20.4± 3.8) mm, t=3.82, P<0.05; (3.3±1.9) vs (2.4±1.7), t=2.26, P<0.05], and the age was younger [(46.0±15.2) years vs (55.0±11.9) years, t=-3.67, P<0.05]. The diffuse enhancement was found in 62 patients, and confluent enhancement in 33 patients. Confluent enhancement was found in all 14 patients after the alcohol ablation procedure. Conclusion: The age, thickness and number of hypertrophic segments in patients with delayed enhancement are different from those with non-delayed enhancement. (authors)

  12. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  13. Dynamic MR imaging of pituitary adenoma

    International Nuclear Information System (INIS)

    Miki, Yukio; Nishizawa, Sadahiko; Kuroda, Yasumasa; Keyaki, Atsushi; Nabeshima, Sachio; Kawamura, Junichiro; Matsuo, Michimasa

    1990-01-01

    The authors performed serial dynamic MR imaging in patients with 10 normal pituitary and 21 pituitary adenoma utilizing spin-echo sequence with a very short repetition time (SE 100/15) every minute immediately after a bolus injection of Gd-DTPA. Usual T 1 -weighted images (SE 600/15) were also obtained before and after the dynamic study. Pituitary adenomas included 10 adenomas confirmed by surgery, 4 adenomas confirmed by biologic data, and 7 postoperative adenomas. Out of 10 patients who underwent surgery after dynamic MRI, 9 patients underwent postoperative dynamic MRI. In normal patients, the pituitary gland was markedly enhanced on the early-phase images of the dynamic study, followed by gradual decrease of intensity throughout the dynamic study. In cases of microadenomas, the contrast between the normal pituitary gland and adenoma is better than that on the usual T 1 -weighted images by marked enhancement of the normal pituitary gland. Dynamic images clearly showed the residual normal pituitary glands in all cases of macroadenoma larger than 15 mm in diameter, whereas usual contrast-enhanced images showed the normal pituitary gland only in one case. In all patients who underwent both preoperative and postoperative dynamic MRI, postoperative dynamic MRI showed the normal pituitary glands which are markedly enhanced on the early-phase images in the sites which correspond to the preoperative dynamic study. The normal residual anterior gland was also visualized in four out of 7 patients who received only postoperative dynamic MRI. Dynamic MRI is a strong diagnostic modality for visualizing microadenoma and for visualizing the normal pituitary gland in cases of preoperative and postoperative macroadenoma. (author)

  14. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Diffusion-weighted imaging versus contrast-enhanced MR imaging for the differentiation of renal oncocytomas and chromophobe renal cell carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yan; Wang, Haiyi; Shen, Yanguang; Ma, Lu; Pan, Jingjing; Ye, Huiyi [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Guo, Aitao [Chinese PLA General Hospital, Department of Pathology, Beijing (China); Wang, Jia [Handan Central Hosptical, Department of Radiology, Hebei (China); Kang, Suhai [264 Hospital of PLA, X-ray Department, Taiyuan (China)

    2017-12-15

    To compare the performance of diffusion-weighted imaging (DWI) with that of contrast-enhanced MRI in differentiating renal oncocytomas from chromophobe renal cell carcinomas (RCCs). We recruited 48 patients with histopathologically confirmed renal oncocytomas (n=16) and chromophobe RCCs (n=32). All patients underwent preoperative DWI and contrast-enhanced MRI. Apparent diffusion coefficient (ADC) and signal intensity were measured in each patient. ADC ratio and percentage of signal intensity change were calculated. Mean ADC values for renal oncocytomas were significantly higher than those for chromophobe RCCs (1.59±0.21 vs. 1.09±0.29 x 10{sup -3} mm{sup 2}/s, p < 0.001). Area under the ROC curve, sensitivity and specificity were 0.931, 87.5% and 84.4%, respectively, for ADC measurement of DW imaging; 0.825, 87.5% and 75%, respectively, for enhancement ratio (p > 0.05). Adding ADC values to the enhancement ratios in the ROC, analysis to differentiate renal oncocytoma from chromophobe RCCs increased specificity from 75 to 87.5% at 87.5% sensitivity without significantly increasing the AUC (0.930). Both DWI and contrast-enhanced MRI may assist in differentiating renal oncocytomas from chromophobe RCCs, with DWI showing higher diagnostic value. The combination of the two parameters could potentially provide better performance in distinguishing these two tumours. (orig.)

  16. Influence of delayed gadolinium enhanced MRI of cartilage (dGEMRIC) protocol on T2-mapping: is it possible to comprehensively assess knee cartilage composition in one post-contrast MR examination at 3 Tesla?

    Science.gov (United States)

    Verschueren, J; van Tiel, J; Reijman, M; Bron, E E; Klein, S; Verhaar, J A N; Bierma-Zeinstra, S M A; Krestin, G P; Wielopolski, P A; Oei, E H G

    2017-09-01

    To evaluate the possibility of assessing knee cartilage with T2-mapping and delayed gadolinium enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) in one post-contrast MR examination at 3 Tesla (T). T2 mapping was performed in 10 healthy volunteers at baseline; directly after baseline; after 10 min of cycling; and after 90 min delay, and in 16 osteoarthritis patients before and after intravenous administration of a double dose gadolinium dimeglumine contrast agent, reflecting key dGEMRIC protocol elements. Differences in T2 relaxation times between each timepoint and baseline were calculated for 6 cartilage regions using paired t tests or Wilcoxon signed-rank tests and the smallest detectable change (SDC). After cycling, a significant change in T2 relaxation times was found in the lateral weight-bearing tibial plateau (+1.0 ms, P = 0.04). After 90 min delay, significant changes were found in the lateral weight-bearing femoral condyle (+1.2 ms, P = 0.03) and the lateral weight-bearing tibial plateau (+1.3 ms, P = 0.01). In these regions of interests (ROIs), absolute differences were small and lower than the corresponding SDCs. T2-mapping after contrast administration only showed statistically significantly lower T2 relaxation times in the medial posterior femoral condyle (-2.4 ms, P T2 relaxation times that were not consistent and lower than the SDC in the majority of regions, our results suggest that T2-mapping and dGEMRIC can be performed reliably in a single imaging session to assess cartilage biochemical composition in knee osteoarthritis (OA) at 3 T. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  17. Adaptive multiscale processing for contrast enhancement

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu; Fan, Jian; Huda, Walter; Honeyman, Janice C.; Steinbach, Barbara G.

    1993-07-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms within a continuum of scale space and used to enhance features of importance to mammography. Choosing analyzing functions that are well localized in both space and frequency, results in a powerful methodology for image analysis. We describe methods of contrast enhancement based on two overcomplete (redundant) multiscale representations: (1) Dyadic wavelet transform (2) (phi) -transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by non-linear, logarithmic and constant scale-space weight functions. Multiscale edges identified within distinct levels of transform space provide a local support for enhancement throughout each decomposition. We demonstrate that features extracted from wavelet spaces can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  18. Reliability and responsiveness of dynamic contrast-enhanced magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Axelsen, M.B.; Poggenborg, R.P.; Stoltenberg, M.

    2013-01-01

    intraarticular injection with 80 mg methylprednisolone. Using semi-automated image processing software, DCE-MRI parameters, including the initial rate of enhancement (IRE) and maximal enhancement (ME), were generated for three regions of interest (ROIs): ‘Whole slice’, ‘Quick ROI’, and ‘Precise ROI......Objectives: To investigate the responsiveness to treatment and the reliability of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in rheumatoid arthritis (RA) knee joints. Methods: DCE-MRI was performed in 12 clinically active RA knee joints before and 1, 7, 30, and 180 days after......’. The smallest detectable difference (SDD), the smallest detectable change (SDC), and intra- and inter-reader intraclass correlation coefficients (ICCs) were used to assess the reliability of DCE-MRI. Responsiveness to treatment was assessed by the standardized response mean (SRM). Results: In all patients...

  19. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    International Nuclear Information System (INIS)

    Andersen, Erlend K.F.; Hole, Knut Håkon; Lund, Kjersti V.; Sundfør, Kolbein; Kristensen, Gunnar B.; Lyng, Heidi; Malinen, Eirik

    2012-01-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile–time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile–time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile–time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile–time interval of nRSI was associated with progression-free survival. Conclusions: The percentile–time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  20. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    Energy Technology Data Exchange (ETDEWEB)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard [University Hospital Heidelberg, Heidelberg Trauma Research Group, Department of Orthopaedic and Trauma Surgery, Heidelberg (Germany); Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Burkholder, Iris [University of Applied Sciences of the Saarland, Department of Nursing and Health, Saarbruecken (Germany)

    2014-02-15

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K{sub trans}, K{sub ep}, iAUC and V{sub e} were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K{sub trans}, K{sub ep} and V{sub e} within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  1. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle.

    Directory of Open Access Journals (Sweden)

    Stefan Hindel

    Full Text Available The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles

  2. Enhancement effects and relaxivities of gadolinium-DTPA at 1.5 versus 3 tesla. A phantom study

    International Nuclear Information System (INIS)

    Sasaki, Makoto; Shibata, Eri; Kanbara, Yoshiyuki; Ehara, Shigeru

    2005-01-01

    The purpose of this study was to investigate the difference in enhancement effects and relaxivities of the gadolinium chelate at 1.5 and 3 Tesla (T) and to elucidate the contribution of the high magnetic field to contrast enhancement in spin-echo (SE) and gradient-echo (GRE) images. Phantoms containing water with or without gadopentetate dimeglumine (Gd-DTPA) at different concentrations were scanned using 1.5T and 3T MRI scanners of the same manufacturer and under the same temperature conditions and scanning parameters. Relaxivities of gadolinium, R 1 and R 2 , were estimated from serial T 1 and T 2 values of the phantoms using linear regression. Contrast enhancement ratios in SE and GRE T 1 -weighted images were compared at 1.5 and 3T. The R 1 and R 2 of Gd-DTPA at 1.5 and 3T were 4.79 and 5.14, and 4.50 and 5.09, respectively. Although the relaxivities at 3T were slightly lower than those at 1.5T, the contrast enhancement ratio improved in both SE and GRE images as a result of T 1 prolongation of the water at 3T. The decrease in relaxivities of the Gd-DTPA at 3T appears to be so small that T 1 prolongation of the water improves contrast enhancement, suggesting a potential clinical advantage in administration of Gd-DTPA at high field strength. (author)

  3. Characterization of Metabolic, Diffusion, and Perfusion Properties in GBM: Contrast-Enhancing versus Non-Enhancing Tumor

    Directory of Open Access Journals (Sweden)

    Adam Autry

    2017-12-01

    Full Text Available BACKGROUND: Although the contrast-enhancing (CE lesion on T1-weighted MR images is widely used as a surrogate for glioblastoma (GBM, there are also non-enhancing regions of infiltrative tumor within the T2-weighted lesion, which elude radiologic detection. Because non-enhancing GBM (Enh− challenges clinical patient management as latent disease, this study sought to characterize ex vivo metabolic profiles from Enh− and CE GBM (Enh+ samples, alongside histological and in vivo MR parameters, to assist in defining criteria for estimating total tumor burden. Methods: Fifty-six patients with newly diagnosed GBM received a multi-parametric pre-surgical MR examination. Targets for obtaining image-guided tissue samples were defined based on in vivo parameters that were suspicious for tumor. The actual location from where tissue samples were obtained was recorded, and half of each sample was analyzed for histopathology while the other half was scanned using HR-MAS spectroscopy. Results: The Enh+ and Enh− tumor samples demonstrated comparable mitotic activity, but also significant heterogeneity in microvascular morphology. Ex vivo spectroscopic parameters indicated similar levels of total choline and N-acetylaspartate between these contrast-based radiographic subtypes of GBM, and characteristic differences in the levels of myo-inositol, creatine/phosphocreatine, and phosphoethanolamine. Analysis of in vivo parameters at the sample locations were consistent with histological and ex vivo metabolic data. CONCLUSIONS: The similarity between ex vivo levels of choline and NAA, and between in vivo levels of choline, NAA and nADC in Enh+ and Enh− tumor, indicate that these parameters can be used in defining non-invasive metrics of total tumor burden for patients with GBM.

  4. Characterization of Metabolic, Diffusion, and Perfusion Properties in GBM: Contrast-Enhancing versus Non-Enhancing Tumor.

    Science.gov (United States)

    Autry, Adam; Phillips, Joanna J; Maleschlijski, Stojan; Roy, Ritu; Molinaro, Annette M; Chang, Susan M; Cha, Soonmee; Lupo, Janine M; Nelson, Sarah J

    2017-12-01

    Although the contrast-enhancing (CE) lesion on T 1 -weighted MR images is widely used as a surrogate for glioblastoma (GBM), there are also non-enhancing regions of infiltrative tumor within the T 2 -weighted lesion, which elude radiologic detection. Because non-enhancing GBM (Enh-) challenges clinical patient management as latent disease, this study sought to characterize ex vivo metabolic profiles from Enh- and CE GBM (Enh+) samples, alongside histological and in vivo MR parameters, to assist in defining criteria for estimating total tumor burden. Fifty-six patients with newly diagnosed GBM received a multi-parametric pre-surgical MR examination. Targets for obtaining image-guided tissue samples were defined based on in vivo parameters that were suspicious for tumor. The actual location from where tissue samples were obtained was recorded, and half of each sample was analyzed for histopathology while the other half was scanned using HR-MAS spectroscopy. The Enh+ and Enh- tumor samples demonstrated comparable mitotic activity, but also significant heterogeneity in microvascular morphology. Ex vivo spectroscopic parameters indicated similar levels of total choline and N-acetylaspartate between these contrast-based radiographic subtypes of GBM, and characteristic differences in the levels of myo-inositol, creatine/phosphocreatine, and phosphoethanolamine. Analysis of in vivo parameters at the sample locations were consistent with histological and ex vivo metabolic data. The similarity between ex vivo levels of choline and NAA, and between in vivo levels of choline, NAA and nADC in Enh+ and Enh- tumor, indicate that these parameters can be used in defining non-invasive metrics of total tumor burden for patients with GBM. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. MRI of the cervical spine with T1-weighted multislice flash sequences

    International Nuclear Information System (INIS)

    Schubeus, P.; Sander, B.; Schoerner, W.; Tosch, U.; Lanksch, W.R.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1990-01-01

    A study has been carried out to evaluate contrast and image quality of cervical structures using multislice 2D-flash sequences with long repetition times (TR = 400 ms.) and short echo delay times (TE = 5.8 ms.). The examinations were carried out using ten normals with an MRI of 1.5 Tesla and flip angles of 10, 20, 30, 50, 70 and 90deg. The best contrast between intervertebral disc and surrounding tissue was obtained between 50 and 70deg, best contrast between compact bone and CSF with 10deg. In order to demonstrate degenerative changes of the cervical spine, it appears sensible to use a combination of these angles. The described sequences produce good images of the cervical structures with little image degradation. Compared to T 1 -weighted spin-echo sequences, the method has a number of significant advantages, such as variations in image contrast, higher maximal number of slices, continuous imaging and less imaging time. (orig.) [de

  6. Difference between T1 and T2 weighted MR images in avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo

    1990-01-01

    T 1 and T 2 weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T 2 weighted images than in T 1 weighted images. The area of low intensity on T 1 weighted image and high on T 2 weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T 1 and T 2 weighted images must be taken into consideration especially in determination of the border of affected bone. (author)

  7. [The use of the T2-weighted turbo-spin-echo sequence in studying the neurocranium. A comparison with the conventional T2-weighted spin-echo sequence].

    Science.gov (United States)

    Siewert, C; Hosten, N; Felix, R

    1994-07-01

    T2-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neurocranium. We evaluated fast spin-echo T2-weighted imaging (TT2) of the neurocranium in comparison to conventional spin-echo T2-weighted imaging (T2). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher in TT2 than in T2 (with the exception of gray-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT2, Parkinson patients have to be examined by conventional T2. If these limitations are taken into account, fast spin-echo T2-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T2-weighting achieved in a short acquisition time.

  8. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    International Nuclear Information System (INIS)

    Knobloch, Gesine; Hamm, Bernd; Jost, Gregor; Pietsch, Hubertus; Huppertz, Alexander

    2014-01-01

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  9. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Knobloch, Gesine; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Jost, Gregor; Pietsch, Hubertus [Bayer Healthcare, MR and CT Contrast Media Research, Berlin (Germany); Huppertz, Alexander [Imaging Science Institute Charite - Siemens, Berlin (Germany)

    2014-08-15

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  10. Assessment of the link between quantitative biexponential diffusion-weighted imaging and contrast-enhanced MRI in the liver

    NARCIS (Netherlands)

    Dijkstra, Hildebrand; Oudkerk, Matthijs; Kappert, Peter; Sijens, Paul E.

    Purpose: To investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions. Methods: Twenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n = 20) or

  11. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  12. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  13. Assessment of dynamic contrast enhancement of the small bowel in active Crohn's disease using 3D MR enterography

    International Nuclear Information System (INIS)

    Knuesel, Patrick R.; Kubik, Rahel A.; Crook, David W.; Eigenmann, Franz; Froehlich, Johannes M.

    2010-01-01

    Purpose: To retrospectively compare the dynamic contrast enhancement of the small bowel segments with and without active Crohn's disease at 3D MR enterography (MRE). Materials and methods: Thirteen patients (five men, eight women; mean age 41.2 years; range 29-56) were imaged on a 1.5-T MR scanner (Sonata, Siemens Medical) with standard MR sequences after having ingested 1000 ml of a 3% mannitol solution. Subsequently, high resolution 3D gradient-echo (volumetric interpolated breath-hold examination = VIBE) data sets were obtained pre-contrast and 20-40 s, 60-80 s, and 120-140 s after i.v. Gd-DOTA administration (0.2 mmol/kg). Signal enhancement was measured on single slices both in normal and histologically confirmed (12/13) inflamed small bowel wall segments as well as in the aorta, the psoas muscle, and the background to calculate signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Results: Small bowel wall enhancement was significantly higher (p < 0.05) in inflamed compared to normal segments at 20-40 s (SNR inflamed: 58.7 ± 33.8 vs normal: 36.0 ± 19.8; p = 0.048; CNR inflamed: 34.8 ± 23.4 vs normal: 16.3 ± 11.2; p = 0.017) and at 60-80 s (SNR: 60.3 ± 25.1 vs 41.9 ± 20.0; p = 0.049; CNR: 34.9 ± 15.1 vs 19.3 ± 13.2; p = 0.01) after i.v. contrast administration, respectively. Even at 120-140 s CNR was still increased in inflamed segments (33.7 ± 16.0 vs 18.1 ± 13.2; p = 0.04), while differences in SNR did not attain statistical significance (63.0 ± 26.2 vs 45.3 ± 23.3; p = 0.15). Conclusion: In active Crohn's disease, histologically confirmed inflamed small bowel wall segments demonstrate a significantly increased early uptake of gadolinium on 3D VIBE sequences compared to normal small bowel segments.

  14. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    International Nuclear Information System (INIS)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung

    2014-01-01

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  15. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung [Yonsei University, Wonju (Korea, Republic of)

    2014-06-15

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  16. Comparison of fast spin echo, fast multiplanner spoiled gradient recalled and conventional T1 and T2 weighted imaging for experimentally induced hepatic tumors in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Suh, Jin Suk; Choi, Pil Sik; Lee, Yeon Hee; Yoo, Hyung Sik; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To compare the ability of tumor detection and the lesion conspicuity between T1- and T2-weighted fast scanning sequence and T1- and T2-weighted conventional spin echo techniques in MR imaging of hepatic tumors. Hepatic tumors were induced on 13 male Sprague-Dawley rats by feeding 3'-methyl-dimethylethyl aminoazobenzene mixed with Miller's III formula for 12 weeks. MR images were obtained with 1.5 T magnet with dual TMJ coil(Sigma, GE Medical systems, Milwaukee, USA). Animals were anesthetized with 150 mg/kg of ketamine hydrochloride. T2 weighted fast spin echo(FSE), conventional spin echo(CSE) T2- and T1WI, fast multiplanner spoiled gradient recalled(FMPSPGR) imaging were obtained. Number of detected tumors and contrast-to-noise ratio of the tumors were compared for each sequence. Overall 110 tumors were developed. 75% of the tumors were detected on FSE. 65% on FMPSPGR, 41% on conventional T2WI, and 41% on T1WI images. For tumors more than 5 mm in diameter, sensitivity was 88% on FMPSPGR, 65% on conventional T2WI, and 81% on T1WI images respectively. CNR of the tumor was 28.94 {+-} 21.6 on FSE, 13.57 {+-} 8.64 on FMPSPGR, 12.62 {+-} 10.65 on CSE T2WI, and 9.47 {+-} 8.05 on CSE T1WI images, which was significantly high on FSE(p<0.05). Fast spin echo T2WI shows highest sensitivity and tumor-to-liver contrast. FMPSPGR imaging is also favorably comparable with conventional T1WI. Therefore, these two pulse sequences can be useful in clinical condition for hepatic MR imaging.

  17. Early changes in perfusion of glioblastoma during radio- and chemotherapy evaluated by T1-dynamic contrast enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møller, Søren; Lundemann, Michael; Law, Ian

    2015-01-01

    months post-Tx. DCE-MRI at three Tesla generated maps of blood flow (BF), blood volume (BV), permeability (Ki) and volume of distribution (Vd) using a combination of model-free deconvolution and Patlak plots. Regions of interest in contrast enhancing tumor and in normal appearing white matter were...

  18. Dynamic contrast-enhanced case-control analysis in 3T MRI of prostate cancer can help to characterize tumor aggressiveness

    Energy Technology Data Exchange (ETDEWEB)

    Sanz-Requena, Roberto, E-mail: roberto.sanz@quironsalud.es [Biomedical Engineering, Hospital Quirónsalud Valencia, Valencia (Spain); Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); Martí-Bonmatí, Luis [Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); Pérez-Martínez, Rosario [Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); García-Martí, Gracián [Biomedical Engineering, Hospital Quirónsalud Valencia, Valencia (Spain); Radiology Department, Hospital Quirónsalud Valencia, Valencia (Spain); GIBI230, Instituto de Investigación Sanitaria y Hospital Universitari i Politècnic La Fe, Valencia (Spain); CIBER-SAM, Instituto de Salud Carlos III, Madrid (Spain)

    2016-11-15

    Highlights: • Curve types showed no statistical association with healthy/tumor peripheral areas. • K{sup trans}, v{sub e}, upslope and AUC showed significant differences in controls vs. tumors. • The global diagnostic performance of standard MRI perfusion parameters is poor. • Normalized K{sup trans}, upslope and AUC had good diagnostic accuracy for tumor grading. - Abstract: Purpose: The aim of this work is to establish normality and tumor tissue ranges for perfusion parameters from dynamic contrast-enhanced (DCE) MR of the peripheral prostate at 3T and to compare the diagnostic performance of quantitative and semi-quantitative parameters. Materials and methods: Thirty-six patients with prostate carcinomas (18 Gleason-6, 15 Gleason-7, and 3 Gleason-8) and 33 healthy subjects were included. Image analysis workflow comprised four steps: manual segmentation of whole prostate and lesions, series registration, voxelwise T1 mapping and calculation of pharmacokinetic and semi-quantitative parameters. Results: K{sup trans}, v{sub e}, upslope and AUC60 showed statistically significant differences between healthy peripheral areas and tumors. Curve type showed no association with healthy/tumor peripheral areas (chi-square = 0.702). Areas under the ROC curves were 0.64 (95% CI: 0.54–0.75), 0.70 (0.60–0.80), 0.62 (0.51–0.72) and 0.63 (0.52–0.74) for K{sup trans}, v{sub e}, upslope and AUC60, respectively. The optimal cutoff values were: K{sup trans} = 0.21 min{sup −1} (sensitivity = 0.61, specificity = 0.64), v{sub e} = 0.36 (0.63, 0.71), upslope = 0.59 (0.59, 0.59) and AUC60 = 2.4 (0.63, 0.64). Significant differences were found between Gleason scores 6 and 7 for normalized K{sup trans}, upslope and AUC60, with good diagnostic accuracy (area under ROC curve 0.80, 95% CI: 0.60–1.00). Conclusion: Quantitative (K{sup trans} and v{sub e}) and semi-quantitative (upslope and AUC60) perfusion parameters showed significant differences between tumors and control

  19. Susceptibility weighted imaging (SWI) of the kidney at 3 T. Initial results

    International Nuclear Information System (INIS)

    Mie, Moritz B.; Zoellner, Frank G.; Heilmann, Melanie; Schad, Lothar R.; Nissen, Johanna C.; Schoenberg, Stefan O.; Michaely, Henrik J.

    2010-01-01

    Susceptibility weighted imaging provides diagnostic information in strokes, hemorrhages, and cerebral tumors and has proven to be a valuable tool in imaging venous vessels in the cerebrum. The SWI principle is based on the weighting of T 2 * weighted magnitude images with a phase mask, therewith improving image contrast of veins or neighbouring structures of different susceptibility, in general. T 2 * weighted MRI is already used for assessment of kidney function. In this paper, the feasibility of SWI on kidneys was investigated. Translation of SWI from the brain to the kidneys comes along with two main challenges: (i) organ motion due to breathing and (ii) a higher oxygenation level of renal veins compared to the brain. To handle these problems, the acquisition time has been cut down to allow for breath-hold examinations, and different post-processing methods including a new phase mask were investigated to visualize renal veins. Results showed that by a new post-processing strategy SWI contrast was enhanced on average by a factor of 1.33 compared to the standard phase mask. In summary, initial experiences of SWI on the kidneys demonstrated the feasibility. However, further technical developments have to be performed to make this technology applicable in clinical abdominal MRI. (orig.)

  20. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.