WorldWideScience

Sample records for t-year maximum discharges

  1. Maximum discharge rate of liquid-vapor mixtures from vessels

    International Nuclear Information System (INIS)

    Moody, F.J.

    1975-09-01

    A discrepancy exists in theoretical predictions of the two-phase equilibrium discharge rate from pipes attached to vessels. Theory which predicts critical flow data in terms of pipe exit pressure and quality severely overpredicts flow rates in terms of vessel fluid properties. This study shows that the discrepancy is explained by the flow pattern. Due to decompression and flashing as fluid accelerates into the pipe entrance, the maximum discharge rate from a vessel is limited by choking of a homogeneous bubbly mixture. The mixture tends toward a slip flow pattern as it travels through the pipe, finally reaching a different choked condition at the pipe exit

  2. Maximum known stages and discharges of New York streams and their annual exceedance probabilities through September 2011

    Science.gov (United States)

    Wall, Gary R.; Murray, Patricia M.; Lumia, Richard; Suro, Thomas P.

    2014-01-01

    Maximum known stages and discharges at 1,400 sites on 796 streams within New York are tabulated. Stage data are reported in feet. Discharges are reported as cubic feet per second and in cubic feet per second per square mile. Drainage areas range from 0.03 to 298,800 square miles; excluding the three sites with larger drainage areas on the St. Lawrence and Niagara Rivers, which drain the Great Lakes, the maximum drainage area is 8,288 square miles (Hudson River at Albany). Most data were obtained from U.S. Geological Survey (USGS) compilations and records, but some were provided by State, local, and other Federal agencies and by private organizations. The stage and discharge information is grouped by major drainage basins and U.S. Geological Survey site number, in downstream order. Site locations and their associated drainage area, period(s) of record, stage and discharge data, and flood-frequency statistics are compiled in a Microsoft Excel spreadsheet. Flood frequencies were derived for 1,238 sites by using methods described in Bulletin 17B (Interagency Advisory Committee on Water Data, 1982), Ries and Crouse (2002), and Lumia and others (2006). Curves that “envelope” maximum discharges within their range of drainage areas were developed for each of six flood-frequency hydrologic regions and for sites on Long Island, as well as for the State of New York; the New York curve was compared with a curve derived from a plot of maximum known discharges throughout the United States. Discharges represented by the national curve range from at least 2.7 to 4.9 times greater than those represented by the New York curve for drainage areas of 1.0 and 1,000 square miles. The relative magnitudes of discharge and runoff in the six hydrologic regions of New York and Long Island suggest the largest known discharges per square mile are in the southern part of western New York and the Catskill Mountain area, and the smallest are on Long Island.

  3. At site and regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region

    International Nuclear Information System (INIS)

    Kohnova, S.; Hlavcova, K.

    2004-01-01

    In this presentation authors deal with the regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region (Slovak Republic). This work has two objectives: (1) At site and regional analysis of annual and seasonal maximum design discharges in the upper Hron region; (2) Analysis of annual and seasonal maximum design precipitations in the connection of extreme runoff condition in the upper Hron region

  4. The n-by-T Target Discharge Strategy for Inpatient Units.

    Science.gov (United States)

    Parikh, Pratik J; Ballester, Nicholas; Ramsey, Kylie; Kong, Nan; Pook, Nancy

    2017-07-01

    Ineffective inpatient discharge planning often causes discharge delays and upstream boarding. While an optimal discharge strategy that works across all units at a hospital is likely difficult to identify and implement, a strategy that provides a reasonable target to the discharge team appears feasible. We used observational and retrospective data from an inpatient trauma unit at a Level 2 trauma center in the Midwest US. Our proposed novel n-by-T strategy-discharge n patients by the Tth hour-was evaluated using a validated simulation model. Outcome measures included 2 measures: time-based (mean discharge completion and upstream boarding times) and capacity-based (increase in annual inpatient and upstream bed hours). Data from the pilot implementation of a 2-by-12 strategy at the unit was obtained and analyzed. The model suggested that the 1-by-T and 2-by-T strategies could advance the mean completion times by over 1.38 and 2.72 h, respectively (for 10 AM ≤ T ≤ noon, occupancy rate = 85%); the corresponding mean boarding time reductions were nearly 11% and 15%. These strategies could increase the availability of annual inpatient and upstream bed hours by at least 2,469 and 500, respectively. At 100% occupancy rate, the hospital-favored 2-by-12 strategy reduced the mean boarding time by 26.1%. A pilot implementation of the 2-by-12 strategy at the unit corroborated with the model findings: a 1.98-h advancement in completion times (Pstrategies, such as the n-by-T, can help substantially reduce discharge lateness and upstream boarding, especially during high unit occupancy. To sustain implementation, necessary commitment from the unit staff and physicians is vital, and may require some training.

  5. Analyzing temporal changes in maximum runoff volume series of the Danube River

    International Nuclear Information System (INIS)

    Halmova, Dana; Pekarova, Pavla; Onderka, Milan; Pekar, Jan

    2008-01-01

    Several hypotheses claim that more extremes in climatic and hydrologic phenomena are anticipated. In order to verify such hypotheses it is inevitable to examine the past periods by thoroughly analyzing historical data. In the present study, the annual maximum runoff volumes with t-day durations were calculated for a 130-year series of mean daily discharge of Danube River at Bratislava gauge (Slovakia). Statistical methods were used to clarify how the maximum runoff volumes of the Danube River changed over two historical periods (1876-1940 and 1941-2005). The conclusion is that the runoff volume regime during floods has not changed significantly during the last 130 years.

  6. Change-Point and Trend Analysis on Annual Maximum Discharge in Continental United States

    Science.gov (United States)

    Serinaldi, F.; Villarini, G.; Smith, J. A.; Krajewski, W. F.

    2008-12-01

    Annual maximum discharge records from 36 stations representing different hydro-climatic regimes in the continental United States with at least 100 years of records are used to investigate the presence of temporal trends and abrupt changes in mean and variance. Change point analysis is performed by means of two non- parametric (Pettitt and CUSUM), one semi-parametric (Guan), and two parametric (Rodionov and Bayesian Change Point) tests. Two non-parametric (Mann-Kendall and Spearman) and one parametric (Pearson) tests are applied to detect the presence of temporal trends. Generalized Additive Model for Location Scale and Shape (GAMLSS) models are also used to parametrically model the streamflow data exploiting their flexibility to account for changes and temporal trends in the parameters of distribution functions. Additionally, serial correlation is assessed in advance by computing the autocorrelation function (ACF), and the Hurst parameter is estimated using two estimators (aggregated variance and differenced variance methods) to investigate the presence of long range dependence. The results of this study indicate lack of long range dependence in the maximum streamflow series. At some stations the authors found a statistically significant change point in the mean and/or variance, while in general they detected no statistically significant temporal trends.

  7. Analysis of the maximum discharge of karst springs

    Science.gov (United States)

    Bonacci, Ognjen

    2001-07-01

    Analyses are presented of the conditions that limit the discharge of some karst springs. The large number of springs studied show that, under conditions of extremely intense precipitation, a maximum value exists for the discharge of the main springs in a catchment, independent of catchment size and the amount of precipitation. Outflow modelling of karst-spring discharge is not easily generalized and schematized due to numerous specific characteristics of karst-flow systems. A detailed examination of the published data on four karst springs identified the possible reasons for the limitation on the maximum flow rate: (1) limited size of the karst conduit; (2) pressure flow; (3) intercatchment overflow; (4) overflow from the main spring-flow system to intermittent springs within the same catchment; (5) water storage in the zone above the karst aquifer or epikarstic zone of the catchment; and (6) factors such as climate, soil and vegetation cover, and altitude and geology of the catchment area. The phenomenon of limited maximum-discharge capacity of karst springs is not included in rainfall-runoff process modelling, which is probably one of the main reasons for the present poor quality of karst hydrological modelling. Résumé. Les conditions qui limitent le débit de certaines sources karstiques sont présentées. Un grand nombre de sources étudiées montrent que, sous certaines conditions de précipitations extrêmement intenses, il existe une valeur maximale pour le débit des sources principales d'un bassin, indépendante des dimensions de ce bassin et de la hauteur de précipitation. La modélisation des débits d'exhaure d'une source karstique n'est pas facilement généralisable, ni schématisable, à cause des nombreuses caractéristiques spécifiques des écoulements souterrains karstiques. Un examen détaillé des données publiées concernant quatre sources karstiques permet d'identifier les raisons possibles de la limitation de l'écoulement maximal: (1

  8. Thermal discharge residence by Lake Michigan Salmonids

    International Nuclear Information System (INIS)

    Romberg, G.P.; Prepejchal, W.

    1975-01-01

    Lake Michigan salmon and trout were tagged with a thermoluminescent dosimeter (TLD) temperature tag to estimate their thermal exposure and residence time at a warm water discharge. Fish were collected, tagged, and released at the Point Beach Nuclear Plant, Two Rivers, Wisconsin, in the fall of 1973 and 1974. Tags were recovered during the same season, primarily from fish recaptured at Point Beach. Average uniform temperature exposure and maximum possible discharge residence time were determined. Appropriate hourly intake and discharge temperatures were averaged to calculate mean temperature exposure for the case of maximum discharge residence. Lowest discharge temperature not included within the period of maximum residence was identified to serve as a possible indicator of avoidance temperature. Mean values for the above parameters were calculated for fish species for each tagging year and are reported with the accompanying range of intake and discharge temperatures

  9. Effects of dripper discharge and irrigation frequency on growth and yield of maize in loess plateau of northwest china

    International Nuclear Information System (INIS)

    Xiukang, W.; Zhanbin, L.; Yingying, X.

    2014-01-01

    A field experiment was conducted at the Changwu Experimental Station in Changwu County, Shaanxi Province, in northwestern China from 2010 to 2011 with four treatments and six replicates in a randomized complete block design to determine appropriate dripper discharge and irrigation frequency for maize (Zea mays, L.) irrigated by drip irrigated system. Dripper discharge was applied to maize 1L/h of dripper discharge, 2 days irrigation frequency and 100% of evaporation from a class a pan (T1), 2, 3 and 4 L/h corresponding to 4, 6 and 8 days irrigation frequency, and deficit irrigation water levels was 90%, 80% and 70% of evaporation (T2, T3 and T4), respectively. The results indicated that longest root, root activity, plant height, leaf area, biomass and grain yields values were highest in T1 in both years. The highest grain yield was obtained of 8.78 and 8.84 t ha-1 under T1 in both years, and the minimum yield was obtained with 8.15 and 7.78 t ha-1 under T4 in 2010 and 2011, respectively. The maximum irrigation water use efficiency (IWUE) was 3.247 and 3.283 kg m-3 in both years under T4. Despite the reduction of growth and grain yield in T3, the dripper discharge was 3L/h, 6 days irrigation frequency and 80% of evaporation was still high and acceptable for maize production and irrigation water use efficiency in Loess Plateau of Northwest China. (author)

  10. Axial magnetic field restriction of plasma sheath in a coaxial discharge

    International Nuclear Information System (INIS)

    Masoud, M. M.; Soliman, H. M.; Ibrahim, F. A.

    1999-01-01

    The study deals with the effect of an applied axial magnetic field on the dynamics and parameters of the plasma sheath and the expanded plasma in a coaxial discharge. Experimental investigations were carried out with a 3 kJ coaxial discharge device of a Mather geometry. The discharge takes place in Hydrogen gas with base pressure of 1 torr. The experiments were conducted with a 10 kV bank voltage, which corresponds to 100 kA discharge currents. The investigations have shown that the maximum axial plasma sheath velocity is decreased by 20% when applying the external axial magnetic field along the coaxial electrodes of intensity 2.6 kG. The experimental results of axial magnetic field intensity B z along the coaxial electrodes indicated that the application of external axial magnetic field causes an increases of B z ∼ 40% at a mid-distance between the breech and the muzzle and a decrease by 75% at the muzzle. The experimental results of expanded plasma electron temperature T e and density n e cleared that when the axial magnetic field is applied the maximum T e is decreased by 2.6 and 3 times, while the maximum n e is increased by 2.8 and 2 times for the first and second half cycles respectively. (author)

  11. Examination of Deposited Layers Composition on the Discharge Chamber Constructional Elements Tokamak T-11M after Two-Year Operation with Lithium Limiter

    International Nuclear Information System (INIS)

    Buzhinskij, O.; Barsuk, V.

    2006-01-01

    In this work the results of the research of internal structural elements state of the T11-M tokamak discharge chamber after two-year operation with lithium limiter are given [V.B. Lazarev, E.A. Azizov et al., Compatibility of the Lithium Capillary Limiter with Plasma in T-11M, 26 th EPS Conf. on Contr. Fusion Plasma Physics, ECA, vol. 231, pp. 845-848, 1999, V.A. Evtikhin, I.E. Lyublinski, A.V. Vertkov et al., Technology Aspects of Lithium Capillary pore Systems Application in Tokamak Device, SOFT-21 (Madrid), A-37, 2000]. The condition of molybdenic wall surface of the discharge chamber and internal steel surface of diagnostic ports has been investigated. X-ray microanalysis of deposited surface of the first wall has shown, that in deposited layer are contained in the main Mo and small amount Cu. In a composition of deposited layer on the ports surface, except the above-named elements, in a small amount is Fe. Because of the instrumental restrictions of this method of analysis, detection opportunity of lithium traces was missing. X-ray diffractometer analysis of deposited layer on the first wall surface has detected a mixture of several phases. The main phase is Li 2 CO 3 , one third from all deposited substance is Li 2 MoO 4 , there is also LiOH-HO phase. The deposited layer on diagnostic ports in the main consists of LiOH-H 2 O phase, there is also Li 2 CO 3 phase. The results of X-ray analysis of a dust probe from the B 4 C coated graphite limiter surface have not detected whatever extra phases, except a crystalline boron carbide phase. (author)

  12. THE 2003 -2007 MINIMUM, MAXIMUM AND MEDIUM DISCHARGE ANALYSIS OF THE LATORIŢA-LOTRU WATER SYSTEM

    Directory of Open Access Journals (Sweden)

    Simona-Elena MIHĂESCU

    2010-06-01

    Full Text Available The 2003 -2007 minimum, maximum and medium discharge analysis of the Latoriţa-Lotru water system From a functional point of view, the Lotru and Latoriţa make up a water system by the junction of the two high hydro energetic potential water flows. The Lotru springs from the Parâng Massif with a spring quota of over 1900m and an outfall quota of 298m, which makes for an altitude difference of 1602m; it is the affluent of the Olt River, has a course length of 76 km and a minimum discharge of 20m3/s. Its reception hollow is of 1024 km2. Latoriţa springs from the Latoriţa Mountains, it is a small river with an average discharge of 2.7m3/s and is an affluent of the Lotru. Together, the two make up a high hydro energetic potential system, valorized in the system of lakes which serve the Ciunget Hydro-Electric Power Plant. Galbenu and Petrimanu are two reservoirs built on the Latoriţa River and on the Lotru, we have Vidra reservoir, Balindru, Mălaia and Brădişor. The discharge analysis of these rivers is very important in view of a good risk management, especially consisting in floods and high level waters, even in the case of artificial water flows such as the Latoriţa-Lotru water system.

  13. Discharge cleaning and wall conditioning in a Novillo Tokamak

    CERN Document Server

    Valencia, R; Camps, E; Contreras, G; Muhl, S

    2002-01-01

    Our Novillo Tokamak is a small toroidal device magnetically confined defined by the main design parameters: R sub o =0.23 m, a sub v =0.08 m, a sub p =0.06 m, B sub T =0.05-0.47 T, I sub p =1-12 kA, n sub e =1-2x10 sup 1 sup 3 cm sup - sup 3 , T sub e =150 eV, T sub i =50 eV. For the initial discharge chamber cleaning we have often used vacuum baking up to 100 deg. C and then conditioning using Taylor discharge cleaning (TDC) in H sub 2 and He. In this work we report that vacuum baking is effective for obtaining a final total pressure of the order of 1.6x10 sup - sup 7 Torr. We have found that a single parameter, the performance parameter (PP), can be used to optimize the TDC method. This parameter represents the quantity of electron and ion energy incident on the chamber wall during the Taylor discharge, it is equal to (I sub p tau), where I sub p is the peak-to-peak plasma current and tau is the plasma current duration. In graphs of PP versus the gas pressure for different oscillator powers, the maximum val...

  14. The Structure of the Class of Maximum Tsallis–Havrda–Chavát Entropy Copulas

    Directory of Open Access Journals (Sweden)

    Jesús E. García

    2016-07-01

    Full Text Available A maximum entropy copula is the copula associated with the joint distribution, with prescribed marginal distributions on [ 0 , 1 ] , which maximizes the Tsallis–Havrda–Chavát entropy with q = 2 . We find necessary and sufficient conditions for each maximum entropy copula to be a copula in the class introduced in Rodríguez-Lallena and Úbeda-Flores (2004, and we also show that each copula in that class is a maximum entropy copula.

  15. Reconstruction of North American drainage basins and river discharge since the Last Glacial Maximum

    Directory of Open Access Journals (Sweden)

    A. D. Wickert

    2016-11-01

    Full Text Available Over the last glacial cycle, ice sheets and the resultant glacial isostatic adjustment (GIA rearranged river systems. As these riverine threads that tied the ice sheets to the sea were stretched, severed, and restructured, they also shrank and swelled with the pulse of meltwater inputs and time-varying drainage basin areas, and sometimes delivered enough meltwater to the oceans in the right places to influence global climate. Here I present a general method to compute past river flow paths, drainage basin geometries, and river discharges, by combining models of past ice sheets, glacial isostatic adjustment, and climate. The result is a time series of synthetic paleohydrographs and drainage basin maps from the Last Glacial Maximum to present for nine major drainage basins – the Mississippi, Rio Grande, Colorado, Columbia, Mackenzie, Hudson Bay, Saint Lawrence, Hudson, and Susquehanna/Chesapeake Bay. These are based on five published reconstructions of the North American ice sheets. I compare these maps with drainage reconstructions and discharge histories based on a review of observational evidence, including river deposits and terraces, isotopic records, mineral provenance markers, glacial moraine histories, and evidence of ice stream and tunnel valley flow directions. The sharp boundaries of the reconstructed past drainage basins complement the flexurally smoothed GIA signal that is more often used to validate ice-sheet reconstructions, and provide a complementary framework to reduce nonuniqueness in model reconstructions of the North American ice-sheet complex.

  16. Risk factors for suicide within a year of discharge from psychiatric hospital: a systematic meta-analysis.

    Science.gov (United States)

    Large, Matthew; Sharma, Swapnil; Cannon, Elisabeth; Ryan, Christopher; Nielssen, Olav

    2011-08-01

    The increased risk of suicide in the period after discharge from a psychiatric hospital is a well-recognized and serious problem. The aim of this study was to establish the risk factors for suicide in the year after discharge from psychiatric hospitals and their usefulness in categorizing patients as high or low risk for suicide in the year following discharge. A systematic meta-analysis of controlled studies of suicide within a year of discharge from psychiatric hospitals. There was a moderately strong association between both a history of self-harm (OR = 3.15) and depressive symptoms (OR = 2.70) and post-discharge suicide. Factors weakly associated with post-discharge suicide were reports of suicidal ideas (OR = 2.47), an unplanned discharge (OR = 2.44), recent social difficulty (OR = 2.23), a diagnosis of major depression (OR = 1.91) and male sex (OR = 1.58). Patients who had less contact with services after discharge were significantly less likely to commit suicide (OR = 0.69). High risk patients were more likely to commit suicide than other discharged patients, but the strength of this association was not much greater than the association with some individual risk factors (OR = 3.94, sensitivity = 0.40, specificity = 0.87). No factor, or combination of factors, was strongly associated with suicide in the year after discharge. About 3% of patients categorized as being at high risk can be expected to commit suicide in the year after discharge. However, about 60% of the patients who commit suicide are likely to be categorized as low risk. Risk categorization is of no value in attempts to decrease the numbers of patients who will commit suicide after discharge.

  17. Variations in tropical cyclone-related discharge in four watersheds near Houston, Texas

    Directory of Open Access Journals (Sweden)

    Laiyin Zhu

    2015-01-01

    Full Text Available We examined a 60-year record of daily precipitation and river discharge related to tropical cyclones (TCs in four watersheds undergoing land use and land cover change near Houston, Texas. Results show that TCs are responsible for ∼20% of the annual maximum discharge events in the four selected watersheds. Although there are no trends in TC precipitation, increasing trends were observed in daily extreme discharge and TC-related discharge. The more developed watersheds (Whiteoak Bayou and Brays Bayou, tend to have higher extreme discharge and steeper trends in extreme discharge than the less developed watersheds (Cypress Creek. Increases in TC-related extreme discharges correspond with increases in developed land and decreases in vegetated land between 1980 and 2006. Therefore, changes in land cover/use in watersheds near Houston are a major cause of the increased flooding risk in recent years.

  18. FDX: a fast discharge homopolar generator

    International Nuclear Information System (INIS)

    Weldon, W.F.; Rylander, H.G.; Woodson, H.H.

    1977-01-01

    A study was undertaken to determine the fundamental limitations to the discharge times of homopolar generators. As a result of the study, a Fast Discharge Experiment (FDX) was proposed. FDX is a small (365 kJ), counterrotating disk type homopolar generator designed to explore the limits to homopolar generator discharge times. The FDX rotors are forged aluminum alloy with flame sprayed copper slip rings. Solid copper graphite brushes are used with a 95% packing factor on the slip rings. The high magnetic field required for fast discharge (3.6 T average) is provided by discharging the CEM 5.0 MJ homopolar generator into a four-turn, graphite-reinforced, room temperature copper coil. Since the field is pulsed and FDX rotors cannot be self motored, they are brought up to speed with two 37 kW air turbines. The two aluminum rotors are 30 cm in diameter and of a rimmed, modified constant stress configuration. They are designed for a maximum operating speed of 28,000 r/min at which point they each store 182.5 kJ and develop 104 V. The aluminum discharge coax is approximately 38 cm in diameter and is designed to carry the 1.88 MA anticipated from a half speed (14,000 r/min) short circuit discharge which would stop the rotors in 1.0 ms. It is predicted that the machine will ring on its own internal impedance for approximately five cycles in this mode. The discharge coax is shorted by four very fast making switches. Additional impedance can be introduced into the discharge circuit by extending the switch coaxes to allow full speed 1.4 MA discharges in approximately 3.5 ms

  19. Maximum Likelihood Dynamic Factor Modeling for Arbitrary "N" and "T" Using SEM

    Science.gov (United States)

    Voelkle, Manuel C.; Oud, Johan H. L.; von Oertzen, Timo; Lindenberger, Ulman

    2012-01-01

    This article has 3 objectives that build on each other. First, we demonstrate how to obtain maximum likelihood estimates for dynamic factor models (the direct autoregressive factor score model) with arbitrary "T" and "N" by means of structural equation modeling (SEM) and compare the approach to existing methods. Second, we go beyond standard time…

  20. Optimization of ECR-breakdown and plasma discharge formation on T-10 tokamak, using X-mode second harmonic of ECR.

    Directory of Open Access Journals (Sweden)

    Roy I.

    2012-09-01

    Full Text Available In order to obtain breakdown and suitable plasma parameters for low-voltage OH start-up, high level of EC-power was injected into T-10 tokamak. Input HF-power was varied in the range of 0.15–1.0 MW. Two HF-launcher systems with different output beams allowed to inject EC-waves with maximum power density 0.25 MW/cm2 and 0.01 MW/cm2. Dependence of breakdown time delay on HF-power was obtained. It was shown, that optimal plasma parameters were achieved in presence of plasma equilibrium currents I=3 kA (input HF-power=1.0 MW. Electron temperature Te=100÷150 eV and electron density ne=5·1012 cm−3 was measured in these discharges. These parameters remained constant during full HF-pulse-length.

  1. Reactor-specific spent fuel discharge projections: 1985 to 2020

    International Nuclear Information System (INIS)

    Heeb, C.M.; Libby, R.A.; Walling, R.C.; Purcell, W.L.

    1986-09-01

    The creation of four spent-fuel data bases that contain information on the projected amounts of spent fuel to be discharged from US commercial nuclear reactors through the year 2020 is described. The data bases contain detailed spent-fuel information from existing, planned, and projected pressurized water reactors (PWR) and boiling water reactors (BWR). The projections are based on individual reactor information supplied by the US reactor owners. The basic information is adjusted to conform to Energy Information Agency (EIA) forecasts for nuclear installed capacity, generation, and spent fuel discharged. The EIA cases considered are: (1) No New Orders with Extended Burnup, (2) No New Orders with Constant Burnup, (3) Middle Case with Extended Burnup, and (4) Middle Case with Constant Burnup. Detailed, by-reactor tables are provided for annual discharged amounts of spent fuel, for storage requirements assuming maximum-at-reactor storage, and for storage requirements assuming maximum-at-reactor plus intra-utility transshipment of spent fuel

  2. Discharge documentation of patients discharged to subacute facilities: a three-year quality improvement process across an integrated health care system.

    Science.gov (United States)

    Gandara, Esteban; Ungar, Jonathan; Lee, Jason; Chan-Macrae, Myrna; O'Malley, Terrence; Schnipper, Jeffrey L

    2010-06-01

    Effective communication among physicians during hospital discharge is critical to patient care. Partners Healthcare (Boston) has been engaged in a multi-year process to measure and improve the quality of documentation of all patients discharged from its five acute care hospitals to subacute facilities. Partners first engaged stakeholders to develop a consensus set of 12 required data elements for all discharges to subacute facilities. A measurement process was established and later refined. Quality improvement interventions were then initiated to address measured deficiencies and included education of physicians and nurses, improvements in information technology, creation of or improvements in discharge documentation templates, training of hospitalists to serve as role models, feedback to physicians and their service chiefs regarding reviewed cases, and case manager review of documentation before discharge. To measure improvement in quality as a result of these efforts, rates of simultaneous inclusion of all 12 applicable data elements ("defect-free rate") were analyzed over time. Some 3,101 discharge documentation packets of patients discharged to subacute facilities from January 1, 2006, through September 2008 were retrospectively studied. During the 11 monitored quarters, the defect-free rate increased from 65% to 96% (p improvements were seen in documentation of preadmission medication lists, allergies, follow-up, and warfarin information. Institution of rigorous measurement, feedback, and multidisciplinary, multimodal quality improvement processes improved the inclusion of data elements in discharge documentation required for safe hospital discharge across a large integrated health care system.

  3. Reactor-specific spent fuel discharge projections, 1987-2020

    International Nuclear Information System (INIS)

    Walling, R.C.; Heeb, C.M.; Purcell, W.L.

    1988-03-01

    The creation of five reactor-specific spent fuel data bases that contain information on the projected amounts of spent fuel to be discharged from U.S. commercial nuclear reactors through the year 2020 is described. The data bases contain detailed spent fuel information from existing, planned, and projected pressurized water reactors (PWR) and boiling water eactors (BWR), and one existing high temperature gas reactor (HTGR). The projections are based on individual reactor information supplied by the U.S. reactor owners. The basic information is adjusted to conform to Energy Information Administration (EIA) forecasts for nuclear installed capacity, generation, and spent fuel discharged. The EIA cases considered are: No New Orders (assumes increasing burnup), No New Orders with No Increased Burnup, Upper Reference (assumes increasing burnup), Upper Reference with No Increased Burnup, and Lower Reference (assumes increasing burnup). Detailed, by-reactor tables are provided for annual discharged amounts of spent fuel, for storage requirements assuming maximum at-reactor storage, and for storage requirements assuming maximum at-reactor storage plus intra-utility transshipment of spent fuel. 8 refs., 8 figs., 10 tabs

  4. Quality of life among older stroke patients in Taiwan during the first year after discharge.

    Science.gov (United States)

    Shyu, Yea-Ing L; Maa, Suh-Hwa; Chen, Sien-Tsong; Chen, Min-Chi

    2009-08-01

    To explore the one-year poststroke trajectories in health-related quality of life and physical function in a sample of older stroke patients in Taiwan. Health-related quality of life has repeatedly been reported as decreased in poststroke patients. The vast majority of information on the health-related quality of life of older patients after stroke is based on data collected in Western developed countries. In contrast, little is known about older stroke patients in Asian countries. A descriptive, prospective and correlational design was used. Older stroke survivors (n = 98) were assessed at the end of one, three, six and 12 months after hospital discharge for health-related quality of life (measured by the Medical Outcomes Study Short Form 36) and physical functioning (measured by the Chinese Barthel Index and Instrumental Activities of Daily Living Scale). The subjects, who were 65-88 years old, performed considerably worse at 12 months after hospital discharge in social and physical functioning (means = 61.1, 54.8, respectively) than the age-matched community-dwelling norm (means = 78.7, 69.7, respectively). During the first year after discharge, subjects improved significantly on the Medical Outcomes Study Short Form 36 physical component summary scale and role limitations due to physical problems; during the first three months after discharge, they improved significantly on performance of activities of daily living and instrumental activities of daily living; and from the third to sixth month after discharge, they improved significantly in physical functioning. The first year, especially the first three months after hospital discharge, is critical for improvements in health-related quality of life and physical functioning for older stroke survivors in Taiwan. Older Taiwanese/Chinese people who suffer a stroke will likely benefit from interventions during the first 12 months after discharge and the most effective interventions may be earlier, during the first

  5. 33 CFR 154.1029 - Worst case discharge.

    Science.gov (United States)

    2010-07-01

    ... facility. The discharge from each pipe is calculated as follows: The maximum time to discover the release from the pipe in hours, plus the maximum time to shut down flow from the pipe in hours (based on... vessel regardless of the presence of secondary containment; plus (2) The discharge from all piping...

  6. Summary of personnel doses and discharge of radioactivity at Swedish nuclear power plants 1971-1975

    International Nuclear Information System (INIS)

    Malmqvist, L.; Persson, Aa.

    1977-01-01

    The report is a summary of personnel doses and activity discharges from Swedish nuclear power plants during the first five years of electric power production by nuclear plants. The personnel doses for the Sweedish plants are lower than the corresponding values for American plants. The highest Swedish value is o,13 manrem per MWE and year. The discharge of radioactivity to the atmosphere from the Swedish plants has been for below the maximum permissible limits. The discharge of radioactivity to the water recipients was less than 1 % of what is permissible

  7. Development and performance of high speed processing system of magnetohydrodynamic equilibria for discharge analyses on the J T-60 tokamak

    International Nuclear Information System (INIS)

    Hasegawa, Yukihiro; Nakamura, Yukiharu; Shirai, Hiroshi; Hamamatsu, Kiyotaka; Harada, Yoshio; Kikuchi, Mitsuru; Nakata, Yoshihiro

    1999-01-01

    In order to provide a set of magnetohydrodynamic (MHD) equilibrium database which is indispensable for both the studies on improvement of energy confinement and stabilization of MHD activities in tokamaks, a high speed data-processing system synchronizing with J T-60 discharge sequence was newly developed by utilizing the latest model of hugh speed workstation and by optimizing the parallel processing technique to perform fast calculation of MHD equilibria. This high speed system was found to have a sufficient ability to complete the whole equilibrium calculations during each inter-shot period. Cooperating with the mass data storage subsystem preserving the latest equilibrium database automatically, the animated discharge monitoring subsystem provides valuable information for the J T-60 operator to determine control parameters of the succeeding discharge. This report describes the system performance realized in the J T-60 experiment. (author)

  8. Reactor-specific spent fuel discharge projections: 1986 to 2020

    International Nuclear Information System (INIS)

    Heeb, C.M.; Walling, R.C.; Purcell, W.L.

    1987-03-01

    The creation of five reactor-specific spent fuel data bases that contain information on the projected amounts of spent fuel to be discharged from US commercial nuclear reactors through the year 2020 is described. The data bases contain detailed spent-fuel information from existing, planned, and projected pressurized water reactors (PWR) and boiling water reactors (BWR). The projections are based on individual reactor information supplied by the US reactor owners. The basic information is adjusted to conform to Energy Information Agency (EIA) forecasts for nuclear installed capacity, generation, and spent fuel discharged. The EIA cases considered are: (1) No new orders with extended burnup, (2) No new orders with constant burnup, (3) Upper reference (which assumes extended burnup), (4) Upper reference with constant burnup, and (5) Lower reference (which assumes extended burnup). Detailed, by-reactor tables are provided for annual discharged amounts of spent fuel, for storage requirements assuming maximum-at-reactor storage, and for storage requirements assuming maximum-at-reactor plus intra-utility transshipment of spent fuel. 6 refs., 8 figs., 8 tabs

  9. Estimation of peak discharge quantiles for selected annual exceedance probabilities in northeastern Illinois

    Science.gov (United States)

    Over, Thomas M.; Saito, Riki J.; Veilleux, Andrea G.; Sharpe, Jennifer B.; Soong, David T.; Ishii, Audrey L.

    2016-06-28

    This report provides two sets of equations for estimating peak discharge quantiles at annual exceedance probabilities (AEPs) of 0.50, 0.20, 0.10, 0.04, 0.02, 0.01, 0.005, and 0.002 (recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years, respectively) for watersheds in Illinois based on annual maximum peak discharge data from 117 watersheds in and near northeastern Illinois. One set of equations was developed through a temporal analysis with a two-step least squares-quantile regression technique that measures the average effect of changes in the urbanization of the watersheds used in the study. The resulting equations can be used to adjust rural peak discharge quantiles for the effect of urbanization, and in this study the equations also were used to adjust the annual maximum peak discharges from the study watersheds to 2010 urbanization conditions.The other set of equations was developed by a spatial analysis. This analysis used generalized least-squares regression to fit the peak discharge quantiles computed from the urbanization-adjusted annual maximum peak discharges from the study watersheds to drainage-basin characteristics. The peak discharge quantiles were computed by using the Expected Moments Algorithm following the removal of potentially influential low floods defined by a multiple Grubbs-Beck test. To improve the quantile estimates, regional skew coefficients were obtained from a newly developed regional skew model in which the skew increases with the urbanized land use fraction. The drainage-basin characteristics used as explanatory variables in the spatial analysis include drainage area, the fraction of developed land, the fraction of land with poorly drained soils or likely water, and the basin slope estimated as the ratio of the basin relief to basin perimeter.This report also provides the following: (1) examples to illustrate the use of the spatial and urbanization-adjustment equations for estimating peak discharge quantiles at ungaged

  10. The spatio-temporal dynamic pattern of rural domestic solid waste discharge of China and its challenges.

    Science.gov (United States)

    Tian, Guangjin; Kong, Lingqiang; Liu, Xiaojuan; Yuan, Wenping

    2018-04-01

    At present, construction of rural domestic waste treatment facilities is seriously lagging, and in many cases, treatment facilities do not yet exist in some villages of China. Serious rural waste pollution has not only impacted the quality of surface water and groundwater but also the atmosphere and the living environment of farmers of China. There are relatively few studies of rural domestic waste pollution, especially with respect to the spatio-temporal dynamic pattern of rural domestic waste discharge. Using survey data and income per capita, we calculated rural domestic waste discharge per capita per day. From this, we calculated provincial rural domestic waste discharge. According to our study, rural domestic waste discharge was 1.42 × 10 8 t/year in 2000. This number increased to 2.3 × 10 8 t/year in 2006 and to 2.47 × 10 8 t/year in 2010. Rural domestic waste increased dramatically while the actual rural population and the proportion of the rural population declined. When examining the eight regions, the rural domestic waste discharge of northeastern China, Qinghai-Tibet, middle China, and southwestern China had increased dramatically, while that of northern China, southern China, and eastern China increased relatively slowly. The economies of northern China, southern China, and eastern China are more developed; their rural domestic waste discharge has been high since 2000 and has continued to increase slowly. In northeastern China, Qinghai-Tibet, middle China, and southwestern China, rural domestic waste discharge was low in 2000; however, in the ten-year period from 2000 to 2010, their rural domestic waste discharge increased dramatically.

  11. Life satisfaction in people with spinal cord injury during the first five years after discharge from inpatient rehabilitation.

    Science.gov (United States)

    van Leeuwen, Christel M C; Post, Marcel W M; van Asbeck, Floris W A; Bongers-Janssen, Helma M H; van der Woude, Lucas H V; de Groot, Sonja; Lindeman, Eline

    2012-01-01

    To describe the course of life satisfaction in persons with spinal cord injury (SCI) during the first 5 years after discharge from inpatient rehabilitation and to examine its determinants. Multi-centre prospective cohort study with four measurements, the first at discharge from inpatient rehabilitation, the last 5 years after discharge. Data of 162 persons with SCI were analyzed. Life satisfaction was measured as the sum score of 'current life satisfaction' and 'current life satisfaction compared to life satisfaction before SCI'. Lesion characteristics, functional independence, secondary impairments, pain, social support and self-efficacy were analyzed as possible determinants of life satisfaction. Random coefficient analysis was used for the analyses. No significant changes in life satisfaction were found between discharge and 2 years later, however there were significant increases from two to 5 years post discharge. High functional independence, low pain, high everyday social support and high self-efficacy were significant determinants of a positive course of life satisfaction after discharge. Increases in life satisfaction were found in persons with SCI in the long run. High functional status, low pain, good social skills and high self-efficacy were related to high life satisfaction.

  12. Density limit in ASDEX discharges with peaked density profiles

    International Nuclear Information System (INIS)

    Staebler, A.; Niedermeyer, H.; Loch, R.; Mertens, V.; Mueller, E.R.; Soeldner, F.X.; Wagner, F.

    1989-01-01

    Results concerning the density limit in OH and NI-heated ASDEX discharges with the usually observed broad density profiles have been reported earlier: In ohmic discharges with high q a (q-cylindrical is used throughout this paper) the Murakami parameter (n e R/B t ) is a good scaling parameter. At the high densities edge cooling is observed causing the plasma to shrink until an m=2-instability terminates the discharge. When approaching q a =2 the density limit is no longer proportional to I p ; a minimum exists in n e,max (q a ) at q a ∼2.15. With NI-heating the density limit increases less than proportional to the heating power; the behaviour during the pre-disruptive phase is rather similar to the one of OH discharges. There are specific operating regimes on ASDEX leading to discharges with strongly peaked density profiles: the improved ohmic confinement regime, counter neutral injection, and multipellet injection. These regimes are characterized by enhanced energy and particle confinement. The operational limit in density for these discharges is, therefore, of great interest having furthermore in mind that high central densities are favourable in achieving high fusion yields. In addition, further insight into the mechanisms of the density limit observed in tokamaks may be obtained by comparing plasmas with rather different density profiles at their maximum attainable densities. 7 refs., 2 figs

  13. Optimization of Highway Work Zone Decisions Considering Short-Term and Long-Term Impacts

    Science.gov (United States)

    2010-01-01

    year when rehabilitation is conducted c0 vph Maximum discharge rate without work zone cw vph Maximum discharge rate with work zone CT $/project...vehicle class Q(t) vph Time-varying traffic flow volume Qp,max vph Maximum allowed diverted volume q(t) veh Time-varying number of vehicles in queue...and road capacity=1600 vph . Unlike single-regime Greenshield’s model, the traffic flow model converted from CORSIM car-following logic is multi

  14. Aetiological Agents of Ear Discharge: A Two year Review in a ...

    African Journals Online (AJOL)

    Journal Home > Vol 48, No 2 (2014) > ... Methodology: This was a retrospective review of laboratory records of all ear swabs submitted for culture over a two year ... Data was obtained on demographic characteristics of patients, clinical ... of the discharging ear was Pseudomonas spp followed by Staphylococcus aureus.

  15. Evaluation of Fatigue Behavior and Surface Characteristics of Aluminum Alloy 2024 T6 After Electric Discharge Machining

    Science.gov (United States)

    Mehmood, Shahid; Shah, Masood; Pasha, Riffat Asim; Sultan, Amir

    2017-10-01

    The effect of electric discharge machining (EDM) on surface quality and consequently on the fatigue performance of Al 2024 T6 is investigated. Five levels of discharge current are analyzed, while all other electrical and nonelectrical parameters are kept constant. At each discharge current level, dog-bone specimens are machined by generating a peripheral notch at the center. The fatigue tests are performed on four-point rotating bending machine at room temperature. For comparison purposes, fatigue tests are also performed on the conventionally machined specimens. Linearized SN curves for 95% failure probability and with four different confidence levels (75, 90, 95 and 99%) are plotted for each discharge current level as well as for conventionally machined specimens. These plots show that the electric discharge machined (EDMed) specimens give inferior fatigue behavior as compared to conventionally machined specimen. Moreover, discharge current inversely affects the fatigue life, and this influence is highly pronounced at lower stresses. The EDMed surfaces are characterized by surface properties that could be responsible for change in fatigue life such as surface morphology, surface roughness, white layer thickness, microhardness and residual stresses. It is found that all these surface properties are affected by changing discharge current level. However, change in fatigue life by discharge current could not be associated independently to any single surface property.

  16. Discharge residence of TLD tagged fish

    International Nuclear Information System (INIS)

    Romberg, G.P.; Prepejchal, W.

    1974-01-01

    Although visual observations suggested that fish remained in the discharge for considerable periods, temperature-sensitive tags indicated the majority of fish spend less than 50 hr or 10 percent of the time at discharge temperatures. During 1974 a second fish tagging study was conducted, using temperature-sensitive tags to yield discharge residence times of Lake Michigan salmonids at Point Beach thermal discharge. Preliminary results revealed that many fish tag values were close to Unit I line indicating that calculated maximum discharge residence times for these fish will be nearly 100 percent of the elapsed time

  17. Turbulence suppression in discharges with off-axis ECRH on the T-10 tokamak device

    International Nuclear Information System (INIS)

    Shelukhin, D.A.; Vershkov, V.A.; Razumova, K.A.

    2005-01-01

    A transient steep electron temperature gradient has been observed in T-10 tokamak plasmas at ρ=0.25 immediately after off-axis electron cyclotron resonance heating (ECRH) switch-off. The turbulence characteristics were investigated in these discharges by means of correlation reflectometry. It was found that the density fluctuation amplitude was two times lower than the ohmic level in a narrow region near ρ=0.25 after ECRH switch-off. The poloidal coherence of fluctuations is also decreased in this region. The suppression of quasi-coherent oscillations has been observed in discharges during the time when the strong temperature gradient exists. Measurements of turbulent poloidal rotation showed no velocity shear after ECRH switch-off. Analysis of the linear growth rates of instabilities shows that the ion temperature gradient (ITG) mode is unstable at ρ ∼ 0.25 during the whole discharge. A possible explanation for the observed phenomena is the rational surface density decrease near q=1 due to q profile transient flattening after off-axis ECRH switch-off. (author)

  18. Discharge Estimation in a Lined Canal Using Information Entropy

    Directory of Open Access Journals (Sweden)

    Yen-Chang Chen

    2014-03-01

    Full Text Available This study applies a new method and technology to measure the discharge in a lined canal in Taiwan. An Acoustic Digital Current Meter mounted on a measurement platform is used to measure the velocities over the full cross-section for establishing the measurement method. The proposed method primarily employs Chiu’s Equation which is based on entropy to establish a constant ratio the relation between the maximum and mean velocities in an irrigation canal, and compute the maximum velocity by the observed velocity profile. In consequence, the mean velocity of the lined canal can be rapidly determined by the maximum velocity and the constant ratio. The cross-sectional area of the artificial irrigation canal can be calculated for the water stage. Finally, the discharge in the lined canal can be efficiently determined by the estimated mean velocity and the cross-sectional area. Using the data of discharges and stages collected in the Wan-Dan Canal, the correlation of stage and discharge is also developed for remote real-time monitoring and estimating discharge from the pumping station. Overall, Chiu’s Equation is demonstrated to reliably and accurately measure discharge in a lined canal, and can serve as reference for future calibration for a stage-discharge rating curve.

  19. Forage yield and nutritive value of Panicum maximum genotypes in the Brazilian savannah

    Directory of Open Access Journals (Sweden)

    Francisco Duarte Fernandes

    2014-02-01

    Full Text Available The narrow genetic variability of grasslands and the incidence of new biotic and abiotic stresses have motivated the selection of new Panicum maximum genotypes for use as forage for beef cattle in the Brazilian savannah. This study aimed to evaluate forage yield and nutritive value of P. maximum genotypes including 14 accessions (PM30 to PM43, four intraspecific hybrids (PM44 to PM47 and six cultivars (Aruana, Massai, Milênio, Mombaça, Tanzania and Vencedor, examining 24 genotypes over two years (2003 and 2004. Milênio cultivar was the genotype with the highest dry matter yield (DMY in both years (18.4 t ha-1 and 20.9 t ha-1, respectively although it presented a high proportion of stems (~ 30%. Genotypes that showed higher Leaf DMY in both years were the accession PM34 (14.7 t ha-1 and the hybrid PM46 (14.0 t ha-1, while Mombaça and Tanzania yielded 12.5 and 11.0 t ha-1, respectively. Leaf organic matter digestibility and leaf DMY for PM40 and PM46 genotypes exceeded the mean (> 656 g kg-1 and > 11.7 t ha-1, respectively. For this reason, PM40 and PM46 can be considered promising P. maximum genotypes for use as forage for grazing systems in the Brazilian savannah.

  20. A pulser-sustainer carbon monoxide electric-discharge supersonic laser

    Science.gov (United States)

    Monson, D. J.; Srinivasan, G.

    1977-01-01

    Operation of a CW CO electric-discharge supersonic laser with a pulser-sustainer discharge is described. High-power operation as well as independent control over electron energy and density are demonstrated. Maximum input power achieved to date is 100 kW. The maximum output power is 6 kW or 10% of the sustainer positive-column power. Much improved performance appears possible.

  1. Wheelchair exercise capacity in spinal cord injury up to five years after discharge from inpatient rehabilitation

    NARCIS (Netherlands)

    van Koppenhagen, Casper F.; de Groot, Sonja; Post, Marcel W. M.; van Asbeck, Floris W. A.; Spijkerman, Dorien; Faber, Willemijn X. M.; Lindeman, Eline; van der Woude, Lucas H. V.

    Objective: To elucidate the course and determinants of wheelchair exercise capacity in spinal cord injury up to 5 years after discharge from inpatient rehabilitation, and to describe loss to follow-up. Design: Prospective cohort study, with measurements at the start and discharge from inpatient

  2. Enhanced performance of high current discharges in JET produced by ICRF heating during the current rise

    International Nuclear Information System (INIS)

    Bures, M.; Bhatnagar, V.; Christiansen, J.P.

    1989-01-01

    The performance of high current discharges can be improved by applying central ICRF heating before or shortly after the onset of sawtooth activity in the plasma current rise phase. Long sawtooth-free periods have been obtained which result in a transiently-enhanced discharge performance. High T c (0) = 9-10.5 keV with peaked profile T e (0)/ e > = 3-4 were obtained giving values of N e (0)T e (0) up to 6 x 10 20 (keV m -3 ). Improvements in T i (0) and neutron production are observed. A best value of n Dd (0)T i (0)τ E = 1.65 x 10 20 (m -3 keV s) was achieved. Local transport simulation shows that the electron and ion thermal diffusivities do not differ substantially in the two cases of current-rise (CR) and flat-top (FT) heating, the performance of the central plasma region being enhanced, in the case of current-rise, entirely by the elimination of the sawtooth instability. The maximum D-D reaction rate is enhanced by a factor of 2 compared to the flat-top value. An appreciable part of the reaction rate is attributed to 2nd harmonic deuterium (2ω CD ) heating. In all current-rise discharges radiation amounts to 25-50% of total power and Ζ eff remains roughly constant. (author)

  3. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    Energy Technology Data Exchange (ETDEWEB)

    Londer, Ya. I.; Ul’yanov, K. N., E-mail: kulyanov@vei.ru [Lenin All-Russian Electrotechnical Institute (Russian Federation)

    2013-10-15

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v{sub 0} to their thermal velocity v{sub T}. It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v{sub 0}/v{sub T}, the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v{sub i}(0), and ratio v{sub 0}/v{sub T} at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v{sub i}{sup *}(0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v{sub i}{sup *} (0) on ρ(0), E(0), and v{sub 0}/v{sub T} determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge.

  4. Generalized Bohm’s criterion and negative anode voltage fall in electric discharges

    International Nuclear Information System (INIS)

    Londer, Ya. I.; Ul’yanov, K. N.

    2013-01-01

    The value of the voltage fall across the anode sheath is found as a function of the current density. Analytic solutions are obtained in a wide range of the ratio of the directed velocity of plasma electrons v 0 to their thermal velocity v T . It is shown that the voltage fall in a one-dimensional collisionless anode sheath is always negative. At the small values of v 0 /v T , the obtained expression asymptotically transforms into the Langmuir formula. Generalized Bohm’s criterion for an electric discharge with allowance for the space charge density ρ(0), electric field E(0), ion velocity v i (0), and ratio v 0 /v T at the plasma-sheath interface is formulated. It is shown that the minimum value of the ion velocity v i * (0) corresponds to the vanishing of the electric field at one point inside the sheath. The dependence of v i * (0) on ρ(0), E(0), and v 0 /v T determines the boundary of the existence domain of stationary solutions in the sheath. Using this criterion, the maximum possible degree of contraction of the electron current at the anode is determined for a short high-current vacuum arc discharge

  5. Capacitor discharge engineering

    CERN Document Server

    Früngel, Frank B A

    1976-01-01

    High Speed Pulse Technology, Volume III: Capacitor Discharge Engineering covers the production and practical application of capacitor dischargers for the generation and utilization of high speed pulsed of energy in different forms. This nine-chapter volume discusses the principles of electric current, voltage, X-rays, gamma rays, heat, beams of electrons, neutrons and ions, magnetic fields, sound, and shock waves in gases and liquids. Considerable chapters consider the applications of capacitor discharges, such as impulse hardening of steel, ultrapulse welding of precision parts, X-ray flash t

  6. Better off in the community? A 5-year follow up study of long-term psychiatric patients discharged into the community.

    LENUS (Irish Health Repository)

    McInerney, Shane J

    2010-04-01

    The quality of life of long-term psychiatric inpatients relocated to the community was investigated in this study. The aim was to investigate what changes, if any occurred, on standardised quality of life related instruments between discharge from hospital and at 1 year after discharge into the community. We were also interested to see if these changes continued 5 years after discharge into the community.

  7. Influence of Climate Change on River Discharge in Austria

    Directory of Open Access Journals (Sweden)

    Robert A. Goler

    2016-10-01

    Full Text Available The effect of climate change on the river discharge characteristics in four catchment basins within Austria is investigated using a hydrological model. Input for the model are daily climate data generated from three regional climate models (RCMs over the time period 1951–2100 using the A1B emission scenario. Due to the complex terrain of the basins, the climate data has been downscaled to a resolution of 1km×1km$1\\,\\text{km}\\times1\\,\\text{km}$. The hydrological model includes processes such as meltwater from snow and glaciers; surface, subsurface, and groundwater flows; and evapotranspiration. The modelling results show that, although only one RCM exhibits a significant reduction in the mean annual discharge towards the end of the 21st century, all RCMs exhibit significant changes in the seasonal distribution of the discharge. In particular, for basins whose discharge is dependent on water stored as snow, there will be a shift in the time of maximum river discharge to earlier in the year as the snow and ice melt earlier. During the winter months the discharge is forecasted to be higher than at present, which would lead to the number of days of low discharge being reduced. However, the earlier snow melt means that the available water for the summer months will be reduced, leading to lower discharges than present, and thus an increase in the number of low discharge days.

  8. The maximum earthquake in future T years: Checking by a real catalog

    International Nuclear Information System (INIS)

    Pisarenko, V.F.; Rodkin, M.V.

    2015-01-01

    The studies of disaster statistics are being largely carried out in recent decades. Some recent achievements in the field can be found in Pisarenko and Rodkin (2010). An important aspect in the seismic risk assessment is the using historical earthquake catalogs and the combining historical data with instrumental ones since historical catalogs cover very long time periods and can improve seismic statistics in the higher magnitude domain considerably. We suggest the new statistical technique for this purpose and apply it to two historical Japan catalogs and the instrumental JMA catalog. The main focus of these approaches is on the occurrence of disasters of extreme sizes as the most important ones from practical point of view. Our method of statistical analysis of the size distribution in the uppermost range of extremely rare events was suggested, based on maximum size M max (τ) (e.g. earthquake energy, ground acceleration caused by earthquake, victims and economic losses from natural catastrophes, etc.) that will occur in a prescribed time interval τ. A new approach to the problem discrete data that we called “the magnitude spreading” is suggested. This method reduces discrete random value to continuous ones by addition a small uniformly distributed random components. We analyze this method in details and apply it to verification of parameters derived from two historical catalogs: the Usami earthquake catalog (599–1884) and the Utsu catalog (1885–1925). We compare their parameters with ones derived from the instrumental JMA catalog (1926–2014). The results of this verification are following: The Usami catalog is incompatible with the instrumental one, whereas parameters estimated from the Utsu catalog are statistically compatible in the higher magnitude domain with sample of M max (τ) derived from the JMA catalog

  9. High-repetition-rate short-pulse gas discharge.

    Science.gov (United States)

    Tulip, J; Seguin, H; Mace, P N

    1979-09-01

    A high-average-power short-pulse gas discharge is described. This consists of a volume-preionized transverse discharge of the type used in gas lasers driven by a Blumlein energy storage circuit. The Blumlein circuit is fabricated from coaxial cable, is pulse-charged from a high-repetition-rate Marx-bank generator, and is switched by a high-repetition-rate segmented rail gap. The operation of this discharge under conditions typical of rare-gas halide lasers is described. A maximum of 900 pps was obtained, giving a power flow into the discharge of 30 kW.

  10. Simulating extreme low-discharge events for the Rhine using a stochastic model

    Science.gov (United States)

    Macian-Sorribes, Hector; Mens, Marjolein; Schasfoort, Femke; Diermanse, Ferdinand; Pulido-Velazquez, Manuel

    2017-04-01

    The specific features of hydrological droughts make them more difficult to be analysed than other water-related phenomena: longer time scales (months to several years) so less historical events are available, and the drought severity and associate damage depends on a combination of variables with no clear prevalence (e.g., total water deficit, maximum deficit and duration). As part of drought risk analysis, which aims to provide insight into the variability of hydrological conditions and associated socio-economic impacts, long synthetic time series should therefore be developed. In this contribution, we increase the length of the available inflow time series using stochastic autoregressive modelling. This enhancement could improve the characterization of the extreme range and can define extreme droughts with similar periods of return but different patterns that can lead to distinctly different damages. The methodology consists of: 1) fitting an autoregressive model (AR, ARMA…) to the available records; 2) generating extended time series (thousands of years); 3) performing a frequency analysis with different characteristic variables (total, deficit, maximum deficit and so on); and 4) selecting extreme drought events associated with different characteristic variables and return periods. The methodology was applied to the Rhine river discharge at location Lobith, where the Rhine enters The Netherlands. A monthly ARMA(1,1) autoregressive model with seasonally varying parameters was fitted and successfully validated to the historical records available since year 1901. The maximum monthly deficit with respect to a threshold value of 1800 m3/s and the average discharge for a given time span in m3/s were chosen as indicators to identify drought periods. A synthetic series of 10,000 years of discharges was generated using the validated ARMA model. Two time spans were considered in the analysis: the whole calendar year and the half-year period between April and September

  11. Numerical study on discharge process of microcavity plasma

    International Nuclear Information System (INIS)

    Xia Guangqing; Xue Weihua; Wang Dongxue; Zhu Guoqiang; Zhu Yu

    2012-01-01

    The evolution of plasma parameters during high pressure discharge in the microcavity with a hollow anode was numerically studied, with a two-dimensional self-consistent fluid model. The simulations were performed with argon at 13.3 kPa. The numerical results show that during the discharge the electric field around the cathode transforms from an axial field to a radial field, the plasma density gets the maximum value on the central line of the cavity and the location of the maximum density moves from the region near anode at the initial stage to the cathode vicinity at the stable stage, and the maximum electron temperature occurs in the ring sheath of cathode. (authors)

  12. Analytical solution for the problem of maximum exit velocity under Coulomb friction in gravity flow discharge chutes

    Energy Technology Data Exchange (ETDEWEB)

    Salinic, Slavisa [University of Kragujevac, Faculty of Mechanical Engineering, Kraljevo (RS)

    2010-10-15

    In this paper, an analytical solution for the problem of finding profiles of gravity flow discharge chutes required to achieve maximum exit velocity under Coulomb friction is obtained by application of variational calculus. The model of a particle which moves down a rough curve in a uniform gravitational field is used to obtain a solution of the problem for various boundary conditions. The projection sign of the normal reaction force of the rough curve onto the normal to the curve and the restriction requiring that the tangential acceleration be non-negative are introduced as the additional constraints in the form of inequalities. These inequalities are transformed into equalities by introducing new state variables. Although this is fundamentally a constrained variational problem, by further introducing a new functional with an expanded set of unknown functions, it is transformed into an unconstrained problem where broken extremals appear. The obtained equations of the chute profiles contain a certain number of unknown constants which are determined from a corresponding system of nonlinear algebraic equations. The obtained results are compared with the known results from the literature. (orig.)

  13. Plasma flow discharge researches at the PIRIT-2000 facility

    International Nuclear Information System (INIS)

    Popkov, N.F.; Ryaslov, E.A.; Kargin, V.I.; Pikar', A.S.; Vorontsov, V.I.; Kotel'nikov, D.V.; Melkozerov, A.V.

    1996-01-01

    Investigation of a plasma flow switch at the PIRIT-2000 fast operating capacitor bank is reported. The maximum current of the plasma flow discharge (PFD) reaches 5 MA, the current rise time being as low as 100 ns. The magnetic field strength of the plasma flow switch (0.15 T) is about 15 times higher than that of the plasma erosion switch used earlier. Both magnetic probe and optical methods were used in the experiments. From the magnetic probes data the propagating velocity of a current carrying shell (205 cm/s) has been derived, while the optical method is used for determining the velocity of a glowing plasma layer. At varying the operation delay in the range 2-10 s the PFD load current rise time increases up to 150-200 ns, the prepulse increment reaching its maximum at the delays higher than 6 s. (J.U.). 5 figs., 5 refs

  14. Plasma flow discharge researches at the PIRIT-2000 facility

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, N F; Ryaslov, E A; Kargin, V I; Pikar` , A S; Vorontsov, V I; Kotel` nikov, D V; Melkozerov, A V [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Investigation of a plasma flow switch at the PIRIT-2000 fast operating capacitor bank is reported. The maximum current of the plasma flow discharge (PFD) reaches 5 MA, the current rise time being as low as 100 ns. The magnetic field strength of the plasma flow switch (0.15 T) is about 15 times higher than that of the plasma erosion switch used earlier. Both magnetic probe and optical methods were used in the experiments. From the magnetic probes data the propagating velocity of a current carrying shell (205 cm/s) has been derived, while the optical method is used for determining the velocity of a glowing plasma layer. At varying the operation delay in the range 2-10 s the PFD load current rise time increases up to 150-200 ns, the prepulse increment reaching its maximum at the delays higher than 6 s. (J.U.). 5 figs., 5 refs.

  15. Closed form analytic solutions describing glow discharge plasma

    International Nuclear Information System (INIS)

    Pai, S.T.; Guo, X.M.; Zhou, T.D.

    1996-01-01

    On the basis of an analytic model developed previously [S. T. Pai, J. Appl. Phys. 71, 5820 (1992)], an improved version of the model for the description of dc glow discharge plasma was successfully developed. A set of closed form solutions was obtained from the governing equations. The two-dimensional, analytic solutions are functional and completely satisfy the governing equations, the actual boundary conditions, and Maxwell equations. They can be readily used to carry out numerical calculations without the necessity of employing any assumed boundary conditions. Results obtained from the model reveal that as the discharge gap spacing or pressure increases the maximum value in the electron density distribution moves toward the cathode. At a sufficiently large value of gap spacing, the positive column phenomenon begins to appear in the discharge region. The model has the capability of treating the positive column and negative glow as a continuous system without the necessity of studying them separately. The model also predicts a sharp rise of the positive ion density near the cathode and field reversal in the anode region. Variation of the electrode radius produces little effect on the axial spatial distribution of physical quantities studied. copyright 1996 American Institute of Physics

  16. Increased West Antarctic and unchanged East Antarctic ice discharge over the last 7 years

    Science.gov (United States)

    Gardner, Alex S.; Moholdt, Geir; Scambos, Ted; Fahnstock, Mark; Ligtenberg, Stefan; van den Broeke, Michiel; Nilsson, Johan

    2018-02-01

    Ice discharge from large ice sheets plays a direct role in determining rates of sea-level rise. We map present-day Antarctic-wide surface velocities using Landsat 7 and 8 imagery spanning 2013-2015 and compare to earlier estimates derived from synthetic aperture radar, revealing heterogeneous changes in ice flow since ˜ 2008. The new mapping provides complete coastal and inland coverage of ice velocity north of 82.4° S with a mean error of image pairs acquired during the daylight period. Using an optimized flux gate, ice discharge from Antarctica is 1929 ± 40 Gigatons per year (Gt yr-1) in 2015, an increase of 36 ± 15 Gt yr-1 from the time of the radar mapping. Flow accelerations across the grounding lines of West Antarctica's Amundsen Sea Embayment, Getz Ice Shelf and Marguerite Bay on the western Antarctic Peninsula, account for 88 % of this increase. In contrast, glaciers draining the East Antarctic Ice Sheet have been remarkably constant over the period of observation. Including modeled rates of snow accumulation and basal melt, the Antarctic ice sheet lost ice at an average rate of 183 ± 94 Gt yr-1 between 2008 and 2015. The modest increase in ice discharge over the past 7 years is contrasted by high rates of ice sheet mass loss and distinct spatial patters of elevation lowering. The West Antarctic Ice Sheet is experiencing high rates of mass loss and displays distinct patterns of elevation lowering that point to a dynamic imbalance. We find modest increase in ice discharge over the past 7 years, which suggests that the recent pattern of mass loss in Antarctica is part of a longer-term phase of enhanced glacier flow initiated in the decades leading up to the first continent-wide radar mapping of ice flow.

  17. Chronological trends in maximum and minimum water flows of the Teesta River, Bangladesh, and its implications

    Directory of Open Access Journals (Sweden)

    Md. Sanaul H. Mondal

    2017-03-01

    Full Text Available Bangladesh shares a common border with India in the west, north and east and with Myanmar in the southeast. These borders cut across 57 rivers that discharge through Bangladesh into the Bay of Bengal in the south. The upstream courses of these rivers traverse India, China, Nepal and Bhutan. Transboundary flows are the important sources of water resources in Bangladesh. Among the 57 transboundary rivers, the Teesta is the fourth major river in Bangladesh after the Ganges, the Brahmaputra and the Meghna and Bangladesh occupies about 2071 km2 . The Teesta River floodplain in Bangladesh accounts for 14% of the total cropped area and 9.15 million people of the country. The objective of this study was to investigate trends in both maximum and minimum water flow at Kaunia and Dalia stations for the Teesta River and the coping strategies developed by the communities to adjust with uncertain flood situations. The flow characteristics of the Teesta were analysed by calculating monthly maximum and minimum water levels and discharges from 1985 to 2006. Discharge of the Teesta over the last 22 years has been decreasing. Extreme low-flow conditions were likely to occur more frequently after the implementation of the Gozoldoba Barrage by India. However, a very sharp decrease in peak flows was also observed albeit unexpected high discharge in 1988, 1989, 1991, 1997, 1999 and 2004 with some in between April and October. Onrush of water causes frequent flash floods, whereas decreasing flow leaves the areas dependent on the Teesta vulnerable to droughts. Both these extreme situations had a negative impact on the lives and livelihoods of people dependent on the Teesta. Over the years, people have developed several risk mitigation strategies to adjust with both natural and anthropogenic flood situations. This article proposed the concept of ‘MAXIN (maximum and minimum flows’ for river water justice for riparian land.

  18. Study of the switching rate of gas-discharge devices based on the open discharge with counter-propagating electron beams

    International Nuclear Information System (INIS)

    Bokhan, P. A.; Gugin, P. P.; Lavrukhin, M. A.; Zakrevsky, Dm. E.

    2015-01-01

    The switching rate of gas-discharge devices “kivotrons” based on the open discharge with counter-propagating electron beams has been experimentally studied. Structures with 2-cm 2 overall cathode area were examined. The switching time was found to show a monotonic decrease with increasing the working-gas helium pressure and with increasing the voltage across the discharge gap at breakdown. The minimum switching time was found to be ∼240 ps at 17 kV voltage, and the maximum rate of electric-current rise limited by the discharge-circuit inductance was 3 × 10 12  A/s

  19. Experiments on toroidal inductively coupled alternating-current gas discharges

    International Nuclear Information System (INIS)

    Lok, J.

    1976-01-01

    This report is on an experimental study of a toroidal, inductively coupled a.c. gas discharge sustained at pressures roughly between one tenth of a Torr and some tens of Torrs. After breakdown is obtained at low pressure, additional gas is let in. The energy is inductively coupled into the electrodeless discharge by means of an iron core transformer of which the toroidal plasma column is the secondary winding. The power dissipated in the plasma is between 80 and 260 kW and is delivered by a motor-generator system at a frequency of 8 kHz for times up to 2 seconds. A toroidal magnetic field of 0.5 T maximum can be supplied in a short pulse. Five different gases (hydrogen, deuterium, helium, argon, and nitrogen) are used. The pressure range in which the discharges are sustained is specified, and the dynamic current-voltage characteristics are given for different pressures. Some typical streak pictures with simultaneously obtained recordings of the time behaviour of the discharge current and of the loop voltage are presented for the initial phase - at low pressure - of the discharge. The shape and the position of fully developed discharges at various pressures are discussed on the basis of photographic observations. The temperature of hydrogen plasmas is derived both from the electrical conductivity and from the emission of line radiation. The values of the temperature obtained in these ways differ in magnitude and in time behaviour. A possible explanation of the discrepancy can be obtained in terms of expansion and contraction of electron density and temperature profiles during a period of the discharge current, if it is taken into account that the main part of the light emission always originates from the outer colder regions of the plasma. In a somewhat different pressure regime, this picture is confirmed by microwave measurements

  20. Two-year post-discharge costs of care among patients treated with transcatheter or surgical aortic valve replacement in Germany.

    Science.gov (United States)

    Kaier, Klaus; von Kampen, Frederike; Baumbach, Hardy; von Zur Mühlen, Constantin; Hehn, Philip; Vach, Werner; Zehender, Manfred; Bode, Christoph; Reinöhl, Jochen

    2017-07-11

    This study presents data on post-discharge costs of care among patients treated with transcatheter or surgical aortic valve replacement over a two year period. Based on a prospective clinical trial, post-discharge utilization of health services and status of assistance were collected for 151 elderly patients via 2250 monthly telephone interviews, valued using standardized unit costs and analysed using two-part regression models. At month 1 post-discharge, total costs of care are substantially elevated (monthly mean: €3506.7) and then remain relatively stable over the following 23 months (monthly mean: €622.3). As expected, the majority of these costs are related to in-hospital care (~98% in month 1 post-discharge and ~72% in months 2-24). Patients that died during follow-up were associated with substantially higher cost estimates of in-hospital care than those surviving the two-year study period, while patients' age and other patient characteristics were of minor relevance. Estimated costs of outpatient care are lower at month 1 than during the rest of the study period, and not affected by the event of death during follow-up. The estimated costs of nursing care are, in contrast, much higher in year 2 than in year 1 and differ substantially by gender and type of procedure as well as by patients' age. Overall, these monthly cost estimates add up to €10,352 for the first and €7467.6 for the second year post-discharge. Substantial cost increases at month 1 post-discharge and in case of death during follow-up are the main findings of the study, which should be taken into account in future economic evaluations on the topic. Application of standardized unit costs in combination with monthly patient interviews allows for a far more precise estimate of the variability in post-discharge health service utilization in this group of patients than the ones given in previous studies. German Clinical Trial Register Nr. DRKS00000797 .

  1. Life satisfaction in people with spinal cord injury during the first five years after discharge from inpatient rehabilitation

    NARCIS (Netherlands)

    van Leeuwen, Christel M. C.; Post, Marcel W. M.; van Asbeck, Floris W. A.; Bongers-Janssen, Helma M. H.; van der Woude, Lucas H. V.; de Groot, Sonja; Lindeman, Eline

    2012-01-01

    Purpose: To describe the course of life satisfaction in persons with spinal cord injury (SCI) during the first 5 years after discharge from inpatient rehabilitation and to examine its determinants. Methods: Multi-centre prospective cohort study with four measurements, the first at discharge from

  2. Aluminum-Enhanced Underwater Electrical Discharges for Steam Explosion Triggering

    International Nuclear Information System (INIS)

    HOGELAND, STEVE R.; NELSON, LLOYD S.; ROTH, THOMAS CHRISTOPHER

    1999-01-01

    For a number of years, we have been initiating steam explosions of single drops of molten materials with pressure and flow (bubble growth) transients generated by discharging a capacitor bank through gold bridgewires placed underwater. Recent experimental and theoretical advances in the field of steam explosions, however, have made it important to substantially increase these relatively mild transients in water without using high explosives, if possible. To do this with the same capacitor bank, we have discharged similar energies through tiny strips of aluminum foil submerged in water. By replacing the gold wires with the aluminum strips, we were able to add the energy of the aluminum-water combustion to that normally deposited electrically by the bridgewire explosion in water. The chemical enhancement of the explosive characteristics of the discharges was substantial: when the same electrical energies were discharged through the aluminum strips, peak pressures increased as much as 12-fold and maximum bubble volumes as much as 5-fold above those generated with the gold wires. For given weights of aluminum, the magnitudes of both parameters appeared to exceed those produced by the underwater explosion of equivalent weights of high explosives

  3. Maximum T/sub c/: optimistic evidence

    International Nuclear Information System (INIS)

    Dynes, R.C.; Allen, P.B.

    1976-01-01

    A reanalysis of Eliashberg theory in the strong coupling limit and the relationship between the superconducting transition temperature T/sub c/ of a material and its normal state properties is presented. At weak and intermediate coupling (lambda approx. 2 >)/sup 1 / 2 /. The lambda = 2 limit predicted by McMillan disappears in the correct theory because it is a result of the functional dependence of T/sub c/ on lambda and used by McMillan which is valid only if lamba 2 (ω)F(ω) for values of lambda < or = 1.5

  4. Excimer lamp pumped by a triggered discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G.; Bollanti, S.; Di Lazzaro, P.; Flora, F.; Giordano, G.; Letardi, T.; Renieri, A.; Schina, G. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Clementi, G.; Muzzi, F.; Zheng, C.E. [EL.EN. (Electronic Engineering), Florence (Italy)

    1996-11-01

    Radiation characteristics and discharge performances of an excimer lamp are described. The discharge of the HCl/Xe gas mixture at an atmospheric pressure, occurring near the quartz tube wall, is initiated by a trigger wire. A maximum total UV energy of about 0.4 J in a (0.8-0.9) {mu}s pulse, radiated from a 10 cm discharge length, is obtained with a total discharge input energy of 8 J. Excimer lamps are the preferred choice for medical and material processing irradiations, when the monochromaticity or coherence of UV light is not required, due to their low cost, reliability and easy maintenance.

  5. Confinement studies of neutral beam heated discharges in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, M.; Arunasalam, V.; Bell, J.D.; Stauffer, F.; Bell, M.G.; Bitte, M.; Blanchard, W.R.; Boody, F.; Britz, N.

    1985-11-01

    The TFTR tokamak has reached its original machine design specifications (I/sub p/ = 2.5 MA and B/sub T/ = 5.2T). Recently, the D/sup 0/ neutral beam heating power has been increased to 6.3 MW. By operating at low plasma current (I/sub p/ approx. = 0.8 MA) and low density anti n/sub e/ approx. = 1 x 10/sup 19/m/sup -3/), high ion temperatures (9 +- keV) and rotation speeds (7 x 10/sup 5/ m/s) have been achieved during injection. At the opposite extreme, pellet injection into high current plasmas has been used to increase the line-average density to 8 x 10/sup 19/m/sup -3/ and the central density to 1.6 x 10/sup 20/m/sup -3// This wide range of operating conditions has enabled us to conduct scaling studies of the global energy confinement time in both ohmically and beam heated discharges as well as more detailed transport studies of the profile dependence. In ohmic discharges, the energy confinement time is observed to scale linearly with density only up to anti n/sub e/ approx. 4.5 x 10/sup 19/m/sup -3/ and then to increase more gradually, achieving a maximum value of approx. 0.45 s. In beam heated discharges, the energy confinement time is observed to decrease with beam power and to increase with plasma current. With P/sub b/ = 5.6 MW, anti n/sub e/ = 4.7 x 10/sup 19/m/sup -3/, I/sub p/ = 2.2 MA and B/sub T = 4.7T, the gross energy confinement time is 0.22 s and T/sub i/(0) = 4.8 keV. Despite shallow penetration of D/sup 0/ beams (at the beam energy less than or equal to 80 keV with low species yield), tau/sub E/(a) values are as large as those for H/sup 0/ injection, but central confinement times are substantially greater. This is a consequence of the insensitivity of the temperature and safety factor profile shapes to the heating profile. The radial variation of tau/sub E/ is even more pronounced with D/sup 0/ injection into high density pellet-injected plasmas. 25 refs.

  6. Increased West Antarctic and unchanged East Antarctic ice discharge over the last 7 years

    Directory of Open Access Journals (Sweden)

    A. S. Gardner

    2018-02-01

    Full Text Available Ice discharge from large ice sheets plays a direct role in determining rates of sea-level rise. We map present-day Antarctic-wide surface velocities using Landsat 7 and 8 imagery spanning 2013–2015 and compare to earlier estimates derived from synthetic aperture radar, revealing heterogeneous changes in ice flow since ∼ 2008. The new mapping provides complete coastal and inland coverage of ice velocity north of 82.4° S with a mean error of < 10 m yr−1, resulting from multiple overlapping image pairs acquired during the daylight period. Using an optimized flux gate, ice discharge from Antarctica is 1929 ± 40 Gigatons per year (Gt yr−1 in 2015, an increase of 36 ± 15 Gt yr−1 from the time of the radar mapping. Flow accelerations across the grounding lines of West Antarctica's Amundsen Sea Embayment, Getz Ice Shelf and Marguerite Bay on the western Antarctic Peninsula, account for 88 % of this increase. In contrast, glaciers draining the East Antarctic Ice Sheet have been remarkably constant over the period of observation. Including modeled rates of snow accumulation and basal melt, the Antarctic ice sheet lost ice at an average rate of 183 ± 94 Gt yr−1 between 2008 and 2015. The modest increase in ice discharge over the past 7 years is contrasted by high rates of ice sheet mass loss and distinct spatial patters of elevation lowering. The West Antarctic Ice Sheet is experiencing high rates of mass loss and displays distinct patterns of elevation lowering that point to a dynamic imbalance. We find modest increase in ice discharge over the past 7 years, which suggests that the recent pattern of mass loss in Antarctica is part of a longer-term phase of enhanced glacier flow initiated in the decades leading up to the first continent-wide radar mapping of ice flow.

  7. Report on radioactive discharges and environmental monitoring at nuclear sites during 1988

    International Nuclear Information System (INIS)

    Short, A.; Davies, A.R.

    1989-09-01

    The details of radioactive discharges from and environmental monitoring in the vicinity of nuclear sites in the Untied Kingdom are presented. The highest predicted dose, resulting from a station's liquid discharges, was to a small group of fish eaters at Trawsfynydd, and is estimated at 120μSv. This is lower than in previous years. Based on the measurements made in marine samples, the dose to a group of fish and shellfish eaters at Heysham is estimated at 160μSv and the external dose to a group living and working on the tidal mud-flats of the nearby Lune Estuary, 120μSv. Only a small fraction of these doses can be attributed to discharges from Heysham. Discharges of Ar-41 are highest from stations with shield cooling air systems. In 1988, the maximum predicted dose associated with Ar-41 releases occurred at Sizewell and was calculated to be 60μSv. At some stations there is a contribution from direct radiation from the plant at locations in close proximity to the boundary fence. In 1988, the estimated highest dose from this source was 0.7mSv and occurs at Bradwell. Radiation doses to members of the public, resulting from discharges and from direct radiation were, in all cases, less than the principal limit of 1mSv/year recommended by ICRP. (author)

  8. Parameters for Fabricating Nano-Au Colloids through the Electric Spark Discharge Method with Micro-Electrical Discharge Machining.

    Science.gov (United States)

    Tseng, Kuo-Hsiung; Chung, Meng-Yun; Chang, Chaur-Yang

    2017-06-02

    In this study, the Electric Spark Discharge Method (ESDM) was employed with micro-electrical discharge machining (m-EDM) to create an electric arc that melted two electrodes in deionized water (DW) and fabricated nano-Au colloids through pulse discharges with a controlled on-off duration (T ON -T OFF ) and a total fabrication time of 1 min. A total of six on-off settings were tested under normal experimental conditions and without the addition of any chemical substances. Ultraviolet-visible spectroscopy (UV-Vis), Zetasizer Nano measurements, and scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analyses suggested that the nano-Au colloid fabricated at 10-10 µs (10 µs on, 10 µs off) had higher concentration and suspension stability than products made at other T ON -T OFF settings. The surface plasmon resonance (SPR) of the colloid was 549 nm on the first day of fabrication and stabilized at 532 nm on the third day. As the T ON -T OFF period increased, the absorbance (i.e., concentration) of all nano-Au colloids decreased. Absorbance was highest at 10-10 µs. The SPR peaks stabilized at 532 nm across all T ON -T OFF periods. The Zeta potential at 10-10 µs was -36.6 mV, indicating that no nano-Au agglomeration occurred and that the particles had high suspension stability.

  9. The discharge behavior of lithium-ion batteries using the Dual-Potential Multi-Scale Multi-Dimensional (MSMD) Battery Model

    DEFF Research Database (Denmark)

    Saeed Madani, Seyed; Swierczynski, Maciej Jozef; Kær, Søren Knudsen

    2017-01-01

    This paper gives insight into the discharge behavior of lithium-ion batteries based on the investigations, which have been done by the researchers [1– 19]. In this article, the battery's discharge behaviour at various discharge rates is studied and surface monitor, discharge curve, volume monitor...... to analysis the discharge behaviour of lithium-ion batteries. The results show that surface monitor plot of discharge curve at 1 C has a decreasing trend and volume monitor plot of maximum temperature in the domain has slightly increasing pattern over the simulation time. For the curves of discharge...... plot of maximum temperature in the domain and maximum temperature in the area are illustrated. Additionally, an external and internal short-circuit treatment for three cases have been studied. The Dual-Potential Multi-Scale Multi-Dimensional (MSMD) Battery Model (BM) was used by ANSYS FLUENT software...

  10. Nitridation Of The A A 2024 T3 Aluminium By The Glow Discharge Plasma Technique

    International Nuclear Information System (INIS)

    Mudjiman, Supardjono; Sujitno, Tjipto; Sudjatmoko

    1996-01-01

    Nitridation of A A 2024 T3 aluminium by means of plasma glow discharge technique has been carried out. For this purpose, the experiments were carried out at the temperature 30 o C, 60 o C, 100 o C, 150 o C, 200 o C, and 250 o C whereas the nitridation time were varied at 5 minutes, 15 minutes, 40 minutes, 90 minutes and 180 minutes. The results showed that the optimum temperature and time of nitridation were 60 o C and 90 minutes respectively and the hardness increased from 115 to 166 KHN

  11. Recommended safety procedures for the selection and use of demonstration-type gas discharge devices in schools

    International Nuclear Information System (INIS)

    1979-01-01

    A 1972 survey of 30 Ottawa secondary schools revealed a total of 347 actual or potential X-ray sources available in these schools. More than half of these sources were gas discharge tubes. Some gas discharge tubes, in particular the cold cathode type, can emit X-rays at significantly high levels. Unless such tubes are used carefully, and with regard for good radiation safety practices, they can result in exposures to students that are in excess of the maximum levels recommended by the International Commission on Radiological Protection. Several cases of the recommended dose being exceeded were found in the classes surveyed. This document has been prepared to assist science teachers and others using demonstration-type gas discharge devices to select and use such devices so as to present negligible risk to themselves and students. Useful information on safety procedures to be followed when performing demonstrations or experiments is included. (J.T.A.)

  12. Probable Maximum Earthquake Magnitudes for the Cascadia Subduction

    Science.gov (United States)

    Rong, Y.; Jackson, D. D.; Magistrale, H.; Goldfinger, C.

    2013-12-01

    The concept of maximum earthquake magnitude (mx) is widely used in seismic hazard and risk analysis. However, absolute mx lacks a precise definition and cannot be determined from a finite earthquake history. The surprising magnitudes of the 2004 Sumatra and the 2011 Tohoku earthquakes showed that most methods for estimating mx underestimate the true maximum if it exists. Thus, we introduced the alternate concept of mp(T), probable maximum magnitude within a time interval T. The mp(T) can be solved using theoretical magnitude-frequency distributions such as Tapered Gutenberg-Richter (TGR) distribution. The two TGR parameters, β-value (which equals 2/3 b-value in the GR distribution) and corner magnitude (mc), can be obtained by applying maximum likelihood method to earthquake catalogs with additional constraint from tectonic moment rate. Here, we integrate the paleoseismic data in the Cascadia subduction zone to estimate mp. The Cascadia subduction zone has been seismically quiescent since at least 1900. Fortunately, turbidite studies have unearthed a 10,000 year record of great earthquakes along the subduction zone. We thoroughly investigate the earthquake magnitude-frequency distribution of the region by combining instrumental and paleoseismic data, and using the tectonic moment rate information. To use the paleoseismic data, we first estimate event magnitudes, which we achieve by using the time interval between events, rupture extent of the events, and turbidite thickness. We estimate three sets of TGR parameters: for the first two sets, we consider a geographically large Cascadia region that includes the subduction zone, and the Explorer, Juan de Fuca, and Gorda plates; for the third set, we consider a narrow geographic region straddling the subduction zone. In the first set, the β-value is derived using the GCMT catalog. In the second and third sets, the β-value is derived using both the GCMT and paleoseismic data. Next, we calculate the corresponding mc

  13. ARMA-Based SEM When the Number of Time Points T Exceeds the Number of Cases N: Raw Data Maximum Likelihood.

    Science.gov (United States)

    Hamaker, Ellen L.; Dolan, Conor V.; Molenaar, Peter C. M.

    2003-01-01

    Demonstrated, through simulation, that stationary autoregressive moving average (ARMA) models may be fitted readily when T>N, using normal theory raw maximum likelihood structural equation modeling. Also provides some illustrations based on real data. (SLD)

  14. AIR ATMOSPHERIC-PRESSURE DISCHARGERS FOR OPERATION IN HIGH-FREQUENCY SWITCHING MODE.

    Directory of Open Access Journals (Sweden)

    L.S. Yevdoshenko

    2013-10-01

    Full Text Available Operation of two designs of compact multigap dischargers has been investigated in a high-frequency switching mode. It is experimentally revealed that the rational length of single discharge gaps in the designs is 0.3 mm, and the maximum switching frequency is 27000 discharges per second under long-term stable operation of the dischargers. It is shown that in pulsed corona discharge reactors, the pulse front sharpening results in increasing the operating electric field strength by 1.3 – 1.8 times.

  15. Oral nutritional support of older (65 years+) medical and surgical patients after discharge from hospital

    DEFF Research Database (Denmark)

    Beck, Anne Marie; Holst, Mette; Rasmussen, Henrik Højgaard

    2013-01-01

    To estimate the effectiveness of oral nutritional support compared to placebo or usual care in improving clinical outcome in older (65 years+) medical and surgical patients after discharge from hospital. Outcome goals were: re-admissions, survival, nutritional and functional status, quality of life...

  16. Maximum And Minimum Temperature Trends In Mexico For The Last 31 Years

    Science.gov (United States)

    Romero-Centeno, R.; Zavala-Hidalgo, J.; Allende Arandia, M. E.; Carrasco-Mijarez, N.; Calderon-Bustamante, O.

    2013-05-01

    Based on high-resolution (1') daily maps of the maximum and minimum temperatures in Mexico, an analysis of the last 31-year trends is performed. The maps were generated using all the available information from more than 5,000 stations of the Mexican Weather Service (Servicio Meteorológico Nacional, SMN) for the period 1979-2009, along with data from the North American Regional Reanalysis (NARR). The data processing procedure includes a quality control step, in order to eliminate erroneous daily data, and make use of a high-resolution digital elevation model (from GEBCO), the relationship between air temperature and elevation by means of the average environmental lapse rate, and interpolation algorithms (linear and inverse-distance weighting). Based on the monthly gridded maps for the mentioned period, the maximum and minimum temperature trends calculated by least-squares linear regression and their statistical significance are obtained and discussed.

  17. High density low-q discharges with D-shaped plasmas in Doublet III

    International Nuclear Information System (INIS)

    Nagami, Masayuki; Yoshida, Hidetoshi; Shinya, Kichiro; Yokomizo, Hideaki; Shimada, Michiya; Ioki, Kimihiro; Izumi, Shigeru; Kitsunezaki, Masao; Jahns, G.

    1981-07-01

    The maximum plasma current in Doublet III is found to be limited by disruptions when the limiter safety factor is approximately 2. However, due to the strong toroidal and shaping field effect on rotational transform at the outer plasma edge associated with a D-shape formation having a vertical elongation of 1.5, the safety factor q sub(a) * estimated from simple geometric considerations for D-shaped plasmas corresponds to values as low as 1.5. These discharges operate stably with considerably higher plasma current than most reactor design studies assume. These low-q discharges show excellent plasma performance: very flat spatial electron temperature progiles, high density operation with anti n sub(e)R/B sub(T) up to 7.8, and good energy confinement producing a volume average β of up to 1% with ohmic heating only. This operational regime appears to be applicable to future high β tokamaks with D-shaped cross section. (author)

  18. Trichomonas vaginalis is very rare among women with vaginal discharge in Podlaskie province, Poland.

    Science.gov (United States)

    Serwin, Agnieszka Beata; Bulhak-Koziol, Violetta; Sokolowska, Marianna; Golparian, Daniel; Unemo, Magnus

    2017-09-01

    Trichomonas vaginalis is the most common curable sexually transmitted pathogen globally. However, in the European Union (EU), trichomoniasis appears to be a rare condition. The aim of this study was to examine the prevalence of T. vaginalis among females attending an STI centre in Bialystok, Poland, using the highly sensitive and specific APTIMA T. vaginalis assay. Consecutive females, referred by gynaecologists mainly because of abnormal vaginal discharge, were diagnosed using wet mount microscopy, culture and APTIMA T. vaginalis assay. Among 272 women studied, 82% were pre- and 18% postmenopausal. The average age was 36.0 ± 13.9 (range: 18-86) years. Abnormal discharge (alone or accompanied by itch or vulvovaginal burning) was the most frequent complain in both groups (66.2% and 48.0%). Erythema and discharge were the most frequent abnormal signs (58.6% and 56.0%). Not a single T. vaginalis-positive sample was detected using wet mount microscopy, culture or APTIMA T. vaginalis assay. Despite using the highly sensitive APTIMA T. vaginalis assay for detection, the pathogen could not be identified in females in the studied setting, similar to results from other EU settings. The need for general screening using NAAT for this pathogen while diagnosing vulvovaginal symptoms in females in Poland appears to be low. © 2017 APMIS. Published by John Wiley & Sons Ltd.

  19. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  20. Vazões máximas e mínimas para bacias hidrográficas da região alto Rio Grande, MG Maximum and minimum discharges for Alto Rio Grande region basins, Minas Gerais state, Brazil

    Directory of Open Access Journals (Sweden)

    Carlos Rogério de Mello

    2010-04-01

    Full Text Available Vazões máximas são grandezas hidrológicas aplicadas a projetos de obras hidráulicas e vazões mínimas são utilizadas para a avaliação das disponibilidades hídricas em bacias hidrográficas e comportamento do escoamento subterrâneo. Neste estudo, objetivou-se à construção de intervalos de confiança estatísticos para vazões máximas e mínimas diárias anuais e sua relação com as características fisiográficas das 6 maiores bacias hidrográficas da região Alto Rio Grande à montante da represa da UHE-Camargos/CEMIG. As distribuições de probabilidades Gumbel e Gama foram aplicadas, respectivamente, para séries históricas de vazões máximas e mínimas, utilizando os estimadores de Máxima Verossimilhança. Os intervalos de confiança constituem-se em uma importante ferramenta para o melhor entendimento e estimativa das vazões, sendo influenciado pelas características geológicas das bacias. Com base nos mesmos, verificou-se que a região Alto Rio Grande possui duas áreas distintas: a primeira, abrangendo as bacias Aiuruoca, Carvalhos e Bom Jardim, que apresentaram as maiores vazões máximas e mínimas, significando potencialidade para cheias mais significativas e maiores disponibilidades hídricas; a segunda, associada às bacias F. Laranjeiras, Madre de Deus e Andrelândia, que apresentaram as menores disponibilidades hídricas.Maximum discharges are applied to hydraulic structure design and minimum discharges are used to characterize water availability in hydrographic basins and subterranean flow. This study is aimed at estimating the confidence statistical intervals for maximum and minimum annual discharges and their relationship wih the physical characteristics of basins in the Alto Rio Grande Region, State of Minas Gerais. The study was developed for the six (6 greatest Alto Rio Grande Region basins at upstream of the UHE-Camargos/CEMIG reservoir. Gumbel and Gama probability distribution models were applied to the

  1. Adaptation of the spore discharge mechanism in the basidiomycota.

    Directory of Open Access Journals (Sweden)

    Jessica L Stolze-Rybczynski

    Full Text Available Spore discharge in the majority of the 30,000 described species of Basidiomycota is powered by the rapid motion of a fluid droplet, called Buller's drop, over the spore surface. In basidiomycete yeasts, and phytopathogenic rusts and smuts, spores are discharged directly into the airflow around the fungal colony. Maximum discharge distances of 1-2 mm have been reported for these fungi. In mushroom-forming species, however, spores are propelled over much shorter ranges. In gilled mushrooms, for example, discharge distances of <0.1 mm ensure that spores do not collide with opposing gill surfaces. The way in which the range of the mechanism is controlled has not been studied previously.In this study, we report high-speed video analysis of spore discharge in selected basidiomycetes ranging from yeasts to wood-decay fungi with poroid fruiting bodies. Analysis of these video data and mathematical modeling show that discharge distance is determined by both spore size and the size of the Buller's drop. Furthermore, because the size of Buller's drop is controlled by spore shape, these experiments suggest that seemingly minor changes in spore morphology exert major effects upon discharge distance.This biomechanical analysis of spore discharge mechanisms in mushroom-forming fungi and their relatives is the first of its kind and provides a novel view of the incredible variety of spore morphology that has been catalogued by traditional taxonomists for more than 200 years. Rather than representing non-selected variations in micromorphology, the new experiments show that changes in spore architecture have adaptive significance because they control the distance that the spores are shot through air. For this reason, evolutionary modifications to fruiting body architecture, including changes in gill separation and tube diameter in mushrooms, must be tightly linked to alterations in spore morphology.

  2. Effects of variability in probable maximum precipitation patterns on flood losses

    Science.gov (United States)

    Zischg, Andreas Paul; Felder, Guido; Weingartner, Rolf; Quinn, Niall; Coxon, Gemma; Neal, Jeffrey; Freer, Jim; Bates, Paul

    2018-05-01

    The assessment of the impacts of extreme floods is important for dealing with residual risk, particularly for critical infrastructure management and for insurance purposes. Thus, modelling of the probable maximum flood (PMF) from probable maximum precipitation (PMP) by coupling hydrological and hydraulic models has gained interest in recent years. Herein, we examine whether variability in precipitation patterns exceeds or is below selected uncertainty factors in flood loss estimation and if the flood losses within a river basin are related to the probable maximum discharge at the basin outlet. We developed a model experiment with an ensemble of probable maximum precipitation scenarios created by Monte Carlo simulations. For each rainfall pattern, we computed the flood losses with a model chain and benchmarked the effects of variability in rainfall distribution with other model uncertainties. The results show that flood losses vary considerably within the river basin and depend on the timing and superimposition of the flood peaks from the basin's sub-catchments. In addition to the flood hazard component, the other components of flood risk, exposure, and vulnerability contribute remarkably to the overall variability. This leads to the conclusion that the estimation of the probable maximum expectable flood losses in a river basin should not be based exclusively on the PMF. Consequently, the basin-specific sensitivities to different precipitation patterns and the spatial organization of the settlements within the river basin need to be considered in the analyses of probable maximum flood losses.

  3. [Effect of maximum blood pressure fluctuation on prognosis of patients with acute ischemic stroke within 24 hours after hospital admission].

    Science.gov (United States)

    Wang, H; Tang, Y; Zhang, Y; Xu, K; Zhao, J B

    2018-05-10

    Objective: To investigate the relationship between the maximum blood pressure fluctuation within 24 hours after admission and the prognosis at discharge. Methods: The patients with ischemic stroke admitted in Department of Neurology of the First Affiliated Hospital of Harbin Medical University within 24 hours after onset were consecutively selected from April 2016 to March 2017. The patients were grouped according to the diagnostic criteria of hypertension. Ambulatory blood pressure of the patients within 24 hours after admission were measured with bedside monitors and baseline data were collected. The patients were scored by NIHSS at discharge. The relationships between the maximum values of systolic blood pressure (SBP) or diastolic blood pressure (DBP) and the prognosis at discharge were analyzed. Results: A total of 521 patients with acute ischemic stroke were enrolled. They were divided into normal blood pressure group (82 cases) and hypertension group(439 cases). In normal blood pressure group, the maximum values of SBP and DBP were all in normal distribution ( P >0.05). The maximum value of SBP fluctuation was set at 146.6 mmHg. After adjustment for potential confounders, the OR for poor prognosis at discharge in patients with SBP fluctuation ≥146.6 mmHg was 2.669 (95 %CI : 0.594-11.992) compared with those with SBP fluctuation blood pressure at admission, the maximum values of SBP and DBP within 24 hours after admission had no relationship with prognosis at discharge. In acute ischemic stroke patients with hypertension at admission, the maximum values of SBP and DBP within 24 hours after admission were associated with poor prognosis at discharge.

  4. acceleration observed in an audio air gas discharge

    International Nuclear Information System (INIS)

    Ragheb, M.S.

    2010-01-01

    an audio air gas discharge enclosed in a pyrex glass of 34 mm diameter and 25 cm long , lead to trace the occurrence of an unusual phenomenon. injected relative huge light spots of intense brightness, distributed regularly on the contour and in the center of one of the discharge electrodes, are observed. very high heat is pronounced on both electrodes, while, one of them is higher than the other it attains 660 degree C in 3-4 minutes. series of photographs and registered video films define and clarify the sequence of events that describe the observed phenomenon. the plasma is created by applying an audio power through the electrodes of an air gas discharge of 10 khz and up to 500 watts power supply. the discharge voltage is up to 900 volts: the discharge current flowing through the plasma attains 360 mA. it is found that the discharge system must attain its optimal working conditions in order to produce the amazing phenomena. the obtained plasma is classified as the maximum conditions borders of a γ-discharge type. at these conditions, the corresponding maximum electron temperature and density are 16 eV and 10 15 cm -3 respectively . the observation system succeeded to reveal and to clarify the sequence of the phenomenon events. in addition, by means of the scanning electron microscope and the energy dispersive x- ray systems, the effects on the electrodes surface are investigated and analyzed. the optical observations, in conjunction with the micrograph and surface microanalysis,demonstrate the collision occurrence, of powered agglomerations groups, to the electrode surface. detailed interpretation of that phenomenon suggests a molecular acceleration gaining their energy from the formed plasma due to optimal discharge working conditions. as a consequence, due to the ions agglomerates size this procedure could be considered as a mesoscopic acceleration technique.

  5. Physical method to assess a probable maximum precipitation, using CRCM datas

    International Nuclear Information System (INIS)

    Beauchamp, J.

    2009-01-01

    'Full text:' For Nordic hydropower facilities, spillways are designed with a peak discharge based on extreme conditions. This peak discharge is generally derived using the concept of a probable maximum flood (PMF), which results from the combined effect of abundant downpours (probable maximum precipitation - PMP) and rapid snowmelt. On a gauged basin, the weather data record allows for the computation of the PMF. However, uncertainty in the future climate raises questions as to the accuracy of current PMP estimates for existing and future hydropower facilities. This project looks at the potential use of the Canadian Regional Climate Model (CRCM) data to compute the PMF in ungauged basins and to assess potential changes to the PMF in a changing climate. Several steps will be needed to accomplish this task. This paper presents the first step that aims at applying/adapting to CRCM data the in situ moisture maximization technique developed by the World Meteorological Organization, in order to compute the PMP at the watershed scale. The CRCM provides output data on a 45km grid at a six hour time step. All of the needed atmospheric data is available at sixteen different pressure levels. The methodology consists in first identifying extreme precipitation events under current climate conditions. Then, a maximum persisting twelve hours dew point is determined at each grid point and pressure level for the storm duration. Afterwards, the maximization ratio is approximated by merging the effective temperature with dew point and relative humidity values. The variables and maximization ratio are four-dimensional (x, y, z, t) values. Consequently, two different approaches are explored: a partial ratio at each step and a global ratio for the storm duration. For every identified extreme precipitation event, a maximized hyetograph is computed from the application of this ratio, either partial or global, on CRCM precipitation rates. Ultimately, the PMP is the depth of the

  6. Physical method to assess a probable maximum precipitation, using CRCM datas

    Energy Technology Data Exchange (ETDEWEB)

    Beauchamp, J. [Univ. de Quebec, Ecole de technologie superior, Quebec (Canada)

    2009-07-01

    'Full text:' For Nordic hydropower facilities, spillways are designed with a peak discharge based on extreme conditions. This peak discharge is generally derived using the concept of a probable maximum flood (PMF), which results from the combined effect of abundant downpours (probable maximum precipitation - PMP) and rapid snowmelt. On a gauged basin, the weather data record allows for the computation of the PMF. However, uncertainty in the future climate raises questions as to the accuracy of current PMP estimates for existing and future hydropower facilities. This project looks at the potential use of the Canadian Regional Climate Model (CRCM) data to compute the PMF in ungauged basins and to assess potential changes to the PMF in a changing climate. Several steps will be needed to accomplish this task. This paper presents the first step that aims at applying/adapting to CRCM data the in situ moisture maximization technique developed by the World Meteorological Organization, in order to compute the PMP at the watershed scale. The CRCM provides output data on a 45km grid at a six hour time step. All of the needed atmospheric data is available at sixteen different pressure levels. The methodology consists in first identifying extreme precipitation events under current climate conditions. Then, a maximum persisting twelve hours dew point is determined at each grid point and pressure level for the storm duration. Afterwards, the maximization ratio is approximated by merging the effective temperature with dew point and relative humidity values. The variables and maximization ratio are four-dimensional (x, y, z, t) values. Consequently, two different approaches are explored: a partial ratio at each step and a global ratio for the storm duration. For every identified extreme precipitation event, a maximized hyetograph is computed from the application of this ratio, either partial or global, on CRCM precipitation rates. Ultimately, the PMP is the depth of the

  7. Scrape-off layer based modelling of the density limit in beryllated JET limiter discharges

    International Nuclear Information System (INIS)

    Borrass, K.; Campbell, D.J.; Clement, S.; Vlases, G.C.

    1993-01-01

    The paper gives a scrape-off layer based interpretation of the density limit in beryllated JET limiter discharges. In these discharges, JET edge parameters show a complicated time evolution as the density limit is approached and the limit is manifested as a non-disruptive density maximum which cannot be exceeded by enhanced gas puffing. The occurrence of Marfes, the manner of density control and details of recycling are essential elements of the interpretation. Scalings for the maximum density are given and compared with JET data. The relation to disruptive density limits, previously observed in JET carbon limiter discharges, and to density limits in divertor discharges is discussed. (author). 18 refs, 10 figs, 1 tab

  8. Same-day discharge after laparoscopic hysterectomy.

    Science.gov (United States)

    Perron-Burdick, Misa; Yamamoto, Miya; Zaritsky, Eve

    2011-05-01

    To estimate readmission rates and emergency care use by patients discharged home the same day after laparoscopic hysterectomy. This was a retrospective case series of patients discharged home the same-day after total or supracervical laparoscopic hysterectomy in a managed care setting. Chart reviews were performed for outcomes of interest which included readmission rates, emergency visits, and surgical and demographic characteristics. The two hysterectomy groups were compared using χ² tests for categorical variables and t tests or Wilcoxon rank-sum tests for continuously measured variables. One-thousand fifteen laparoscopic hysterectomies were performed during the 3-year study period. Fifty-two percent (n=527) of the patients were discharged home the same-day; of those, 46% (n=240) had total laparoscopic hysterectomies and 54% (n=287) had supracervical. Cumulative readmission rates were 0.6%, 3.6%, and 4.0% at 48 hours, 3 months, and 12 months, respectively. The most common readmission diagnoses included abdominal incision infection, cuff dehiscence, and vaginal bleeding. Less than 4% of patients presented for emergency care within 48 or 72 hours, most commonly for nausea or vomiting, pain, and urinary retention. Median uterine weight was 155 g, median blood loss was 70 mL, and median surgical time was 150 minutes. There was no difference in readmission rates or emergency visits for the total compared with the supracervical laparoscopic hysterectomy group. Same-day discharge after laparoscopic hysterectomy is associated with low readmission rates and minimal emergency visits in the immediate postoperative period. Same-day discharge may be a safe option for healthy patients undergoing uncomplicated laparoscopic hysterectomy.

  9. Radiation doses from discharges into the sea at the Oskarshamn nuclear power plants

    International Nuclear Information System (INIS)

    Boge, R.; Nordlinder, S.

    1981-04-01

    Control measurements of the activity discharges and the radioecological concentrations at the Oskarshamn site are reported. The actual discharges were much lower than the allowed maximum discharges. The calculated individual and collective doses are small, and the effect on the recipient is negligible, considering both men and ecosystems. (L.E.)

  10. Reactor-specific spent fuel discharge projections, 1984 to 2020

    International Nuclear Information System (INIS)

    Heeb, C.M.; Libby, R.A.; Holter, G.M.

    1985-04-01

    The original spent fuel utility data base (SFDB) has been adjusted to produce agreement with the EIA nuclear energy generation forecast. The procedure developed allows the detail of the utility data base to remain intact, while the overall nuclear generation is changed to match any uniform nuclear generation forecast. This procedure adjusts the weight of the reactor discharges as reported on the SFDB and makes a minimal (less than 10%) change in the original discharge exposures in order to preserve discharges of an integral number of fuel assemblies. The procedure used in developing the reactor-specific spent fuel discharge projections, as well as the resulting data bases themselves, are described in detail in this report. Discussions of the procedure cover the following topics: a description of the data base; data base adjustment procedures; addition of generic power reactors; and accuracy of the data base adjustments. Reactor-specific discharge and storage requirements are presented. Annual and cumulative discharge projections are provided. Annual and cumulative requirements for additional storage are shown for the maximum at-reactor (AR) storage assumption, and for the maximum AR with transshipment assumption. These compare directly to the storage requirements from the utility-supplied data, as reported in the Spent Fuel Storage Requirements Report. The results presented in this report include: the disaggregated spent fuel discharge projections; and disaggregated projections of requirements for additional spent fuel storage capacity prior to 1998. Descriptions of the methodology and the results are included in this report. Details supporting the discussions in the main body of the report, including descriptions of the capacity and fuel discharge projections, are included. 3 refs., 6 figs., 12 tabs

  11. PSN J11290437+1714095 is a Type Ia supernova (91T-like) near maximum light

    Science.gov (United States)

    Childress, M.; Owen, C.; Scalzo, R.; Yuan, F.; Schmidt, B.; Tucker, B.

    2013-12-01

    We report spectroscopic classification of PSN J11290437+1714095 with the Wide Field Spectrograph (WiFeS - Dopita et al., 2007, ApSS, 310, 255) on the ANU 2.3m telescope at Siding Spring Observatory, NSW Australia, using the B3000/R3000 gratings (3500-9800 A, 1 A resolution). PSN J11290437+1714095 was discovered by TAROT on 2013 Dec 11.09 at mag 15.9 in UGC 6483. A 20 minute spectrum of the SN on 2013 Dec 12.72 shows this to be a Type Ia supernova of the SN 1991T subclass near maximum light.

  12. [Characteristics and loads of key sources of pollutions discharged into Beishi River, Changzhou City].

    Science.gov (United States)

    Li, Chun-Ping; Jiang, Jian-Guo; Chen, Ai-Mei; Wu, Jia-Ling; Fan, Xiu-Juan; Ye, Bin

    2010-11-01

    Choosing the Beishi river, Changzhou City as the study area, the sewage generation, pollutants characteristics and sewage discharge in catchment area of Beishi river were conducted, detailed investigated and monitored. After using pollution coefficients, the yearly loads of all sources of pollutions were calculated to determine the highest sewage. The results showed that: except pH, the high concentration of SS, COD, BOD5, ammonia nitrogen, TN and TP discharged from MSW collecting houses, MSW transfer stations, public toilets and dining in Changzhou city far exceeded the "Integrated Wastewater Discharge Standard" (GB 8978-1996) and "Effluent Discharged into the City Sewer Water Quality Standards" (CJ 3082-1999). Among which: the highest concentration of COD discharged from MSW transfer stations was up to 51 700 mg/L, while the ammonia nitrogen and TN were as high as 1 616 mg/L and 2 044 mg/L in the toilet wastewater. In addition to this, the ratio of wastewater discharged directly into the river through storm water pipe network was higher from MSW houses, MSW transfer stations, public toilets, dining and other waste in Changzhou city. The 125.2 t/a of COD and 40.53 t/a of BOD5 were the two highest concentrations of various sources of pollution. The highest annual polluting loads discharged into Beishi river is dining, followed by the sanitation facilities. Therefore, cutting pollution control of food and sanitation facilities along the river is particularly urgent.

  13. Biological impact assessment of thermal discharges in the vicinity of Madras Atomic Power Station, Kalpakkam, India

    International Nuclear Information System (INIS)

    Shahul Hameed, P.; Syed Mohamed, H.E.; Krishnamoorthy, R.

    2007-01-01

    Madras Atomic Power Station (MAPS), Kalpakkam uses seawater as tertiary coolant at the rate of 35m 3 /sec employing a once through type of circuit. The discharged water travels as a canal and mixes with seawater at the mixing zone. The present study investigated the impact of the discharged thermal effluent on the physical chemical and biological quality of the receiving seawater body. The thermal plume is shore attached and extended up to 300 m from the shore and registered a ΔT of 3-4 degC. The shore attached thermal plume adversely affected the density and distribution of macro benthic animals. The benthos are absent in the mixing zone and their density decreased about 500 m on either side of the mixing zone. The natural shift in the mixing zone provides opportunities for the recolonization of macro benthos. The thermal tolerance study revealed that the experimental fish species Mugil cephalus and Alepeus djidapa did not show any mortality or loss of equilibrium at ΔT 5 degC (33 degC) and ΔT 7 degC (35 degC) and the maximum ΔT recorded at the impact area is 6 degC. The gradual increase in temperature as found in the plume favors the fishes to escape the acute thermal exposures. (author)

  14. Ozone production by a dc corona discharge in air contaminated by n-heptane

    International Nuclear Information System (INIS)

    Pekarek, S

    2008-01-01

    Beneficial purposes of ozone such as elimination of odours, harmful bacteria and mildew can be used for transportation of food, fruits and vegetables with the aim to extend their storage life. To date the main technique used for this purpose in the transportation of these commodities, e.g. by trucks, was cooling. Here a combination of cooling together with the supply of ozone into containers with these commodities is considered. For these purposes we studied the effect of air contamination by n-heptane (part of automotive fuels) and humidity on ozone production by a dc hollow needle to mesh corona discharge. We found that, for both polarities of the needle electrode, addition of n-heptane to air (a) decreases ozone production; (b) causes discharge poisoning to occur at lower current than for air; (c) does not substantially influence the current for which the ozone production reaches the maximum. Finally the maximum ozone production for the discharge in air occurs for the same current as the maximum ozone production for the discharge contaminated by n-heptane. We also found that humidity decreases ozone production from air contaminated by n-heptane irrespective of the polarity of the coronating needle electrode. This dependence is stronger for the discharge with the needle biased positively

  15. Barrier discharge. The transferred charge and ozone synthesis

    International Nuclear Information System (INIS)

    Gibalov, V.I.; Samoilovich, V.G.

    1991-01-01

    We have undertaken an experimental investigation of the influence of the conditions of barrier discharge implementation such as: the discharge gap value, the type of gas, and the polarity and dielectric permittivity of the dielectric electrode on the value of charge transferred in a micro-discharge. It is shown that the increase in the specific capacitance of the electrodes leads to proportional increase in the transferred charge value, reaching 100-200 nC in a discharge gap 1 mm, in air. In this case the amplitude and duration of a current pulse in the microdischarge reach, respectively, 10 to 15 A and 40 ns. It is also demonstrated that in air with increase in the discharge gap value one can observe a decrease in the efficiency of the ozone synthesis whereas in oxygen there exists a more complicated dependence: the maximum of efficiency is observed at a discharge gap value of 0.7 to 1.0 mm. (orig.)

  16. Experimental study of surface dielectric barrier discharge in air and its ozone production

    International Nuclear Information System (INIS)

    Pekárek, Stanislav

    2012-01-01

    For surface dielectric barrier discharge in air we studied the effects of frequency of the driving voltage on dissipated power, asymmetry of amplitudes of the discharge voltage, discharge UV emission, ozone production, ozone production of the discharge with TiO 2 and of the discharge in magnetic field. We found that for a particular voltage the dissipated power is higher for the frequency of the driving voltage of 26.3 kHz than for the frequency of 10.9 kHz; peak values of the positive half-periods of the discharge voltage are higher than peak values of the negative half-periods; intensity of the discharge UV emissions for wavelengths of 320-420 nm is for both frequencies a linear function of power; maximum ozone concentration for the frequency of the driving voltage of 26.3 kHz is obtained with smaller power than for the frequency of 10.9 kHz; placement of TiO 2 particles into the discharge chamber increases for both frequencies of the driving voltage maximum ozone concentration produced by the discharge and for the frequency of the driving voltage of 26.3 kHz increases ozone production yield. Finally, there is no observable effect of magnetic field on concentration of ozone produced by the discharge as well as on production yield. (paper)

  17. Analysis of conditions for magnetron discharge initiation at vacuum camera testing

    International Nuclear Information System (INIS)

    Tzeneva, Raina; Dineff, Peter; Darjanova, Denitza

    2002-01-01

    Models of electric field distribution for two typical cases of vacuum camera internal pressure control are investigated. New relations between the maximum magnetron discharge current value I max and the maximum electric field strength radial component value E τ max are established. (Author)

  18. Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lukes, Petr [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Clupek, Martin [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Babicky, Vaclav [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic); Janda, Vaclav [Department of Water Technology and Environmental Engineering, Institute of Chemical Technology, Technicka 5, 160 28 Prague 6 (Czech Republic); Sunka, Pavel [Department of Pulse Plasma Systems, Institute of Plasma Physics, Academy of Sciences of the Czech Republic, Za Slovankou 3, PO Box 17, 182 21 Prague 8 (Czech Republic)

    2005-02-07

    Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min{sup -1}), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O{sub 2} mixtures with the maximum efficiency (energy yield) of 23 g kW h{sup -1} for 40% argon content.

  19. Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor

    International Nuclear Information System (INIS)

    Lukes, Petr; Clupek, Martin; Babicky, Vaclav; Janda, Vaclav; Sunka, Pavel

    2005-01-01

    Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min -1 ), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O 2 mixtures with the maximum efficiency (energy yield) of 23 g kW h -1 for 40% argon content

  20. Global particle balance and wall recycling properties of long duration discharges on TRIAM-1M

    International Nuclear Information System (INIS)

    Sakamoto, M.; Yuno, M.; Itoh, S.

    2003-01-01

    The longest tokamak discharge with the duration of 11406 s (3 h 10 min) was achieved. The global particle balance has been investigated. In the longest discharge, the global balance between the particle absorption and release of the wall was achieved around t∼30 min and then the fueling was automatically stopped. After that the plasma density was maintained by the recycling flux alone until the end of the discharge. The maximum wall inventory is about 3.6 x 10 20 H at t ∼ 30 min but it is finally released from the wall at the end of the discharge. The global balance seems to be caused by the increase in the hydrogen release from the main chamber resulting from its temperature rise. Moreover, it has been observed a large difference between properties of wall recycling in the continuous gas feed case (i.e. static condition) and the additional gas puff case (i.e. dynamic condition). In the static condition, the effective particle confinement time increases almost linearly to about 10 s during the one-minute discharge. In the dynamic condition, the decay time of the electron density just after the gas puff, i.e. the effective particle confinement time, is 0.2 to 0.3 s during the one-minute discharge. The large difference was also reproduced in the longest discharge. It is considered that the enhanced wall pumping is caused by the increase in fluxes of the diffused ions and charge exchange neutrals due to the additional gas puff. (author)

  1. Flood discharge measurement of a mountain river – Nanshih River in Taiwan

    Directory of Open Access Journals (Sweden)

    Y.-C. Chen

    2013-05-01

    Full Text Available This study proposes a more efficient method of flood discharge measurement in mountain rivers that accounts for personal safety, accuracy, and reliability. Because it is based on the relationships between mean and maximum velocities and between cross-sectional area and gauge height, the proposed method utilizes a flood discharge measurement system composed of an acoustic Doppler profiler and crane system to measure velocity distributions, cross-sectional area, and water depths. The flood discharge measurement system can be used to accurately and quickly measure flood data that is difficult to be collected by the conventional instruments. The measured data is then used to calibrate the parameters of the proposed method for estimating mean velocity and cross-sectional area. Then these observed discharge and gauge height can be used to establish the water stage–discharge rating curve. Therefor continuous and real-time estimations of flood discharge of a mountain river can become possible. The measurement method and system is applied to the Nanshih River at the Lansheng Bridge. Once the method is established, flood discharge of the Nanshih River could be efficiently estimated using maximum velocity and the water stage. Results of measured and estimated discharges of the Nanshih River at the Lansheng Bridge differed only slightly from each other, demonstrating the efficiency and accuracy of the proposed method.

  2. Discharge and infection in retinoblastoma post-enucleation sockets

    Directory of Open Access Journals (Sweden)

    Mourits DL

    2017-03-01

    Full Text Available Daphne L Mourits,1 Dyonne T Hartong,1 Andries E Budding,2 Machteld I Bosscha,1 H Stevie Tan,1 Annette C Moll1 1Department of Ophthalmology, VU University Medical Center, 2Department of Microbiology, Academic Medical Center, Amsterdam, the Netherlands Purpose: To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb. Methods: A questionnaire was filled out by (parents of ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients’ characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. Results: A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often experienced in 75 (39.5%, 127 (66.8%, and 15 (13.2% sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13 of the asymptomatic patients (P<0.001. Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Conclusion: Ocular prosthesis-wearing patients often experienced mucoid

  3. FTIR study of decomposition of carbon dioxide in dc corona discharges

    International Nuclear Information System (INIS)

    Horvath, G; Skalny, J D; Mason, N J

    2008-01-01

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO 2 has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO 2 decomposition is found to be dependent on the voltage, U, with a maximum CO 2 decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO 2 decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  4. FTIR study of decomposition of carbon dioxide in dc corona discharges

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, G; Skalny, J D [Department of Experimental Physics, Comenius University, Mlynska dolina F-2, 842 48, Bratislava (Slovakia); Mason, N J [Open University, Department of Physics and Astronomy, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)

    2008-11-21

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO{sub 2} has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO{sub 2} decomposition is found to be dependent on the voltage, U, with a maximum CO{sub 2} decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO{sub 2} decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  5. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  6. Cathode fall measurement in a dielectric barrier discharge in helium

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Yanpeng; Zheng, Bin; Liu, Yaoge [School of Electric Power, South China University of Technology, Guangzhou 510640 (China)

    2013-11-15

    A method based on the “zero-length voltage” extrapolation is proposed to measure cathode fall in a dielectric barrier discharge. Starting, stable, and discharge-maintaining voltages were measured to obtain the extrapolation zero-length voltage. Under our experimental conditions, the “zero-length voltage” gave a cathode fall of about 185 V. Based on the known thickness of the cathode fall region, the spatial distribution of the electric field strength in dielectric barrier discharge in atmospheric helium is determined. The strong cathode fall with a maximum field value of approximately 9.25 kV/cm was typical for the glow mode of the discharge.

  7. Post-discharge heart failure monitoring program in Turkey: Hit-PoinT

    Science.gov (United States)

    Çavuşoğlu, Yüksel; Zoghi, Mehdi; Eren, Mehmet; Bozçalı, Evin; Kozdağ, Güliz; Şentürk, Tunay; Alicik, Güray; Soylu, Korhan; Sarı, İbrahim; Berilgen, Rida; Temizhan, Ahmet; Gencer, Erkan; Orhan, Ahmet Lütfü; Polat, Veli; Kaderli, Aysel Aydın; Aktoz, Meryem; Zengin, Halit; Aksoy, Mehmet; Selçuk, Mehmet Timur; Ergene, Oktay; Soran, Özlem

    2017-01-01

    Objective: The aim of this study was to assess the efficacy and feasibility of an enhanced heart failure (HF) education with a 6-month telephone follow- up program in post-discharge ambulatory HF patients. Methods: The Hit-Point trial was a multicenter, randomized, controlled trial of enhanced HF education with a 6-month telephone follow-up program (EHFP) vs routine care (RC) in patients with HF and reduced ejection fraction. A total of 248 patients from 10 centers in various geographical areas were randomized: 125 to EHFP and 123 to RC. Education included information on adherence to treatment, symptom recognition, diet and fluid intake, weight monitoring, activity and exercise training. Patients were contacted by telephone after 1, 3, and 6 months. The primary study endpoint was cardiovascular death. Results: Although all-cause mortality didn’t differ between the EHFP and RC groups (p=NS), the percentage of cardiovascular deaths in the EHFP group was significantly lower than in the RC group at the 6-month follow up (5.6% vs. 8.9%, p=0.04). The median number of emergency room visits was one and the median number of all cause hospitalizations and heart failure hospitalizations were zero. Twenty-tree percent of the EHFP group and 35% of the RC group had more than a median number of emergency room visits (p=0.05). There was no significant difference regarding the median number of all–cause or heart failure hospitalizations. At baseline, 60% of patients in EHFP and 61% in RC were in NYHA Class III or IV, while at the 6-month follow up only 12% in EHFP and 32% in RC were in NYHA Class III or IV (p=0.001). Conclusion: These results demonstrate the potential clinical benefits of an enhanced HF education and follow up program led by a cardiologist in reducing cardiovascular deaths and number of emergency room visits with an improvement in functional capacity at 6 months in post-discharge ambulatory HF patients. PMID:27488754

  8. Is There an Association Between Markers of Cardiovascular Autonomic Dysfunction at Discharge From Rehabilitation and Participation 1 and 5 Years Later in Individuals With Spinal Cord Injury?

    Science.gov (United States)

    Rianne Ravensbergen, H J; de Groot, Sonja; Post, Marcel W; Bongers-Janssen, Helma M; van der Woude, Lucas H; Claydon, Victoria E

    2016-09-01

    To determine whether physical activity and participation 1 and 5 years after discharge are associated with measures of cardiovascular autonomic function: prevalence of hypotension and reduced peak heart rate at discharge from initial inpatient spinal cord injury (SCI) rehabilitation. Prospective cohort study. Rehabilitation centers. Individuals with SCI (N=146). Not applicable. We recorded markers of cardiovascular autonomic dysfunction (resting blood pressure and peak heart rate) and personal and lesion characteristics at the time of discharge from rehabilitation. Parameters for participation (social health status dimension of the Sickness Impact Profile) and physical activity (Physical Activity Scale for Individuals with Physical Disabilities [PASIPD]) were measured 1 and 5 years after discharge. Effects of prevalence of cardiovascular autonomic dysfunction were analyzed using linear regression analysis while correcting for possible confounders. We found no significant association between hypotension and social health status dimension of the Sickness Impact Profile or PASIPD, either at 1 or at 5 years after discharge. A significant association between peak heart rate and social health status dimension of the Sickness Impact Profile was found at 1 year after discharge, showing poorer participation in individuals with low peak heart rate (ie, cardiovascular autonomic dysfunction). The unadjusted relation between peak heart rate and the social health status dimension of the Sickness Impact Profile was significant at 5 years, but not when adjusted for confounders. We found associations between peak heart rate and PASIPD for both 1 and 5 years after discharge; however, these were not significant after correction for potential confounding factors. Autonomic dysfunction after SCI is a crucial factor influencing quality of life. We found that cardiovascular autonomic impairment, assessed from low peak heart rate, was associated with reduced participation after 1 year

  9. Enhanced accumulation of U(VI) by Aspergillus oryzae mutant generated by dielectric barrier discharge air plasma

    International Nuclear Information System (INIS)

    Wencheng Song; North China Electric Power University, Beijing; Xiangxue Wang; Soochow University, Suzhou; Wen Tao; Hongqing Wang; Tasawar Hayat; Quaid-I-Azam University, Islamabad; Xiangke Wang; Soochow University, Suzhou; King Abdulaziz University, Jeddah

    2016-01-01

    Aspergillus oryzae was isolated from radionuclides' contaminated soils, and dielectric barrier discharge plasma was used to mutate A. oryzae to improve bioremediation capability of U(VI) pollution. The maximum accumulation capacities of U(VI) on mutated A.oryzae was 627.4 mg/g at T = 298 K and pH = 5.5, which was approximately twice than that of raw A.oryzae. XPS analysis indicated that U(VI) accumulation on mutated A. oryzae was largely attributable to nitrogen- and oxygen-containing functional groups on fungal mycelia. The mutated A. oryzae can be harnessed as bioremediation agents for radionuclides pollution. (author)

  10. Discharge cleaning for a tokamak

    International Nuclear Information System (INIS)

    Ishii, Shigeyuki

    1983-01-01

    Various methods of discharge cleaning for tokamaks are described. The material of the first walls of tokamaks is usually stainless steel, inconel, titanium and so on. Hydrogen is exclusively used as the discharge gas. Glow discharge cleaning (GDC), Taylor discharge cleaning (TDC), and electron cyclotron resonance discharge cleaning (ECR-DC) are discussed in this paper. The cleaning by GDC is made by moving a movable anode to the center of a tokamak vassel. Taylor found the good cleaning effect of induced discharge by high pressure and low power discharge. This is called TDC. When the frequency of high frequency discharge in a magnetic field is equal to that of the electron cyclotron resonance, the break down potential is lowered if the pressure is sufficiently low. The ECR-CD is made by using this effect. In TDC and ECR-DC, the electron temperature, which has a close relation to the production rate of H 0 , can be controlled by the pressure. In GDC, the operating pressure was improved by the radio frequency glow (RG) method. However, there is still the danger of arcing. In case of GDC and ECR-DC, the position of plasma can be controlled, but not in case of TDC. The TDC is accepted by most of takamak devices in the world. (Kato, T.)

  11. Five years on the bumpy road delivering well chemicals for zero harmful discharge

    Energy Technology Data Exchange (ETDEWEB)

    Selle, Olav M.; Paltiel, Sten; Saeten, Jens O.; Nasvik, Haavard

    2006-03-15

    This is a summary of five years development work to qualify environmentally acceptable well chemicals for Heidrun. We will describe the situation as we started the work, what strategy we followed and the ups and downs we experienced as we went along. The focus is on scale inhibitors, scale dissolvers, acid formulations, viscosified fluids and chemicals for zonal isolation/shut-off purposes. The challenge has been to develop biodegradable and low toxic chemicals with equal or better effectiveness and with a reasonable prize compare to {sup b}est in class{sup -}products. The impact this has provided for zero harmful discharge to sea at Haltenbanken will be presented, to show the status as we are entering into year 2005. (Author)

  12. Verification to the RSG-GAS fuel discharge burn-up using SRAC2006 module of COREBN/HIST

    International Nuclear Information System (INIS)

    J-Susilo; T-M-Sembiring; G-R-Sunaryo; M-Imron

    2018-01-01

    For 30 years operation, some of the modifications to the RSG GAS core has been done, that are changes included the type of fuel from U 3 O 8 -Al to U 3 Si 2 -Al with the same density 2.96 gU/cc, the loading pattern of standard fuel elements/fuel control elements from 6/1 & 6/2 to 5/1 pattern, and in core fuel management calculation tool has been change from IAFUEL to BATAN-FUEL. To obtain an extension of the operating license for the next 10 years, the RSG-GAS Periodic Safety Assessment Document is need to prepared. According to the Regulatory Body Chairman Regulation No. 2 2015, RSG-GAS safety assessment should be done independently. As part of this assessment the fuel discharge burn-up must be estimated. In this research, to ensure that the misposition of fuel element in the core has not occurred, the investigation to the document operating report related the fuel placement has been done. Therefore, by using 78 th to 93 rd operation data, verify of the fuel discharge burn-up of the RSG-GAS has been performed by using SRAC2006 module of COREBN/HIST. In addition, the results of these calculations are also made comparative with the operating report data that is calculated by using BATAN-FUEL. Maximum fuel discharge burn-up (57.73 % of U-235) was verified still under permissible value determined by the regulatory body (<60 % of U-235). Maximum differences value between two computer codes was about 2.12 % of U-235 (3.80 %) that is fuel at the B-7 position. Fuel discharge burn-up of RSG-GAS showed almost the same value for each the operation cycle, range of 1.52 % of U-235. So it can be concluded that the RSG-GAS core operation over the last ten years was in good fuel management performance, in accordance with the design. BATAN-FUEL has been conformed well enough with COREBN/HIST. (author)

  13. Modeling and optimization of the multichannel spark discharge

    International Nuclear Information System (INIS)

    Zhang Zhi-Bo; Wu Yun; Jia Min; Song Hui-Min; Li Ying-Hong; Sun Zheng-Zhong

    2017-01-01

    This paper reports a novel analytic model of this multichannel spark discharge, considering the delay time in the breakdown process, the electric transforming of the discharge channel from a capacitor to a resistor induced by the air breakdown, and the varying plasma resistance in the discharge process. The good agreement between the experimental and the simulated results validated the accuracy of this model. Based on this model, the influence of the circuit parameters on the maximum discharge channel number (MDCN) is investigated. Both the input voltage amplitude and the breakdown voltage threshold of each discharge channel play a critical role. With the increase of the input voltage and the decrease of the breakdown voltage, the MCDN increases almost linearly. With the increase of the discharge capacitance, the MDCN first rises and then remains almost constant. With the increase of the circuit inductance, the MDCN increases slowly but decreases quickly when the inductance increases over a certain value. There is an optimal value of the capacitor connected to the discharge channel corresponding to the MDCN. Finally, based on these results, to shorten the discharge time, a modified multichannel discharge circuit is developed and validated by the experiment. With only 6-kV input voltage, 31-channels discharge is achieved. The breakdown voltage of each electrode gap is larger than 3 kV. The modified discharge circuit is certain to be widely used in the PSJA flow control field. (paper)

  14. Plasma sheath dynamics in pinch discharge

    International Nuclear Information System (INIS)

    Mansour, A.A.Abd-Fattah

    1995-01-01

    The main interest of the study was to understand the dynamic and to determine the plasma parameters in the 3.5 meter θ-pinch discharge. The 3.5 meter thetatron plasma device has been reconstructed and developed which consist of four capacitor banks: a) Main pinch capacitor bank, (θ-pinch bank) consists of 40 capacitors connected in parallel each of 1.5 μ F., with maximum energy equal to 48 k Joule. b) Preionization capacitor bank (z-pinch) consists of capacitors connected in series each of 1.5μ F., with maximum energy to 0.94 k Joule. c) Bias field bank consists of 4 capacitors connected in parallel each of 38μ F., with maximum energy equal to 4.46 k Joule. d) Screw pinch capacitor bank consists of 5 capacitors connected in parallel each of 1.5μ F., with maximum energy equal to 6 k Joule

  15. Recurrent vaginal discharge in children.

    Science.gov (United States)

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  16. Investigation of Peculiarities of a High-Voltage Pulsing Corona Discharge in Carbonic Gas and an Feature Using of Such Discharge for CO2 Dissociation

    International Nuclear Information System (INIS)

    Berezina, G.P.; Mirny, V.I.; Omelaenko, O.L.; Us, V.S.

    2006-01-01

    On laboratory stand of plasmochemical reactor the feature of CO 2 dissociation with the purpose of CO production in high-voltage pulsing corona discharge is investigated at a voltage up to 120 kV, a pulse length of a current 0,5 μs a repetition rate up to 100 Hz. Peculiarities of volt-ampere characteristics of such discharge are studied at different pressures of air and carbonic gas in the discharge chamber and construction of an interior electrode. It is established that in conditions of the carried out experiments a maximum efficiency of CO accretion does not exceed 3,5%

  17. Performance of a CW double electric discharge for supersonic CO lasers

    Science.gov (United States)

    Stanton, A. C.; Hanson, R. K.; Mitchner, M.

    1980-01-01

    The results of an experimental investigation of a CW double discharge in supersonic CO mixtures are reported. Stable discharges in CO/N2 and CO/Ar mixtures, with a maximum energy loading of 0.5 eV/CO molecule, were achieved in a small-scale continuous-flow supersonic channel. Detailed measurements of the discharge characteristics were performed, including electrostatic probe measurements of floating potential and electron number density and spectroscopic measurements of the CO vibrational population distributions. The results of these measurements indicate that the vibrational excitation efficiency of the discharge is approximately 60%, for moderate levels of main discharge current. These experiments, on a small scale, demonstrate that the double-discharge scheme provides adequate vibrational energy loading for efficient CO laser operation under CW supersonic flow conditions.

  18. Association of Shoulder Problems in Persons With Spinal Cord Injury at Discharge From Inpatient Rehabilitation With Activities and Participation 5 Years Later.

    Science.gov (United States)

    Eriks-Hoogland, Inge; de Groot, Sonja; Snoek, Govert; Stucki, Gerold; Post, Marcel; van der Woude, Lucas

    2016-01-01

    To examine whether musculoskeletal shoulder pain and limitations in shoulder range of motion (ROM) at discharge from first rehabilitation are associated with activities and participation restrictions 5 years later in persons with spinal cord injury (SCI). Prospective cohort study. Eight specialized SCI rehabilitation centers. Subjects (N=138) with an SCI admitted for first rehabilitation. Not applicable. Peak power output (POpeak), Wheelchair Skills Test (WST), FIM motor score, ability to transfer, Physical Activity Scale for Individuals with Physical Disabilities (PASIPD), mobility range and social behavior subscales of the Sickness Impact Profile 68 (SIPSOC), and employment status. Mean age of the subjects at discharge was 39 years, 72% were men, 32% had tetraplegia, and in 65% the SCI was motor complete. At discharge, 39% reported shoulder pain and 32% had a limited shoulder ROM. In the analyses of variance, shoulder ROM limitation, but not shoulder pain, was associated with all but 1 outcome at 5 years. In the regression analyses, ROM limitations of the shoulder were negatively associated with the ability to transfer (P=.004), FIM motor scores (PPASIPD. The presence of limitations in shoulder ROM, but not shoulder pain, at discharge is associated with limitations in activities and employment status 5 years later. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. DC corona discharge ozone production enhanced by magnetic field

    Science.gov (United States)

    Pekárek, S.

    2010-01-01

    We have studied the effect of a stationary magnetic field on the production of ozone from air at atmospheric pressure by a negative corona discharge in a cylindrical electrode configuration. We used a stainless steel hollow needle placed at the axis of the cylindrical discharge chamber as a cathode. The outer wall of the cylinder was used as an anode. The vector of magnetic induction was perpendicular to the vector of current density. We found that: (a) the magnetic field extends the current voltage range of the discharge; (b) for the discharge in the Trichel pulses regime and in the pulseless glow regime, the magnetic field has no substantial effect on the discharge voltage or on the concentration of ozone that is produced; (c) for the discharge in the filamentary streamer regime for a particular current, the magnetic field increases the discharge voltage and consequently an approximately 30% higher ozone concentration can be obtained; (d) the magnetic field does not substantially increase the maximum ozone production yield. A major advantage of using a magnetic field is that the increase in ozone concentration produced by the discharge can be obtained without additional energy requirements.

  20. 78 FR 691 - Maximum Loan Amount for Business and Industry Guaranteed Loans in Fiscal Year 2013

    Science.gov (United States)

    2013-01-04

    ... DEPARTMENT OF AGRICULTURE Rural Business-Cooperative Service Maximum Loan Amount for Business and Industry Guaranteed Loans in Fiscal Year 2013 AGENCY: Rural Business-Cooperative Service, USDA. ACTION... and Industry (B&I) guaranteed loans of $25 million or less under certain circumstances. Due to the...

  1. Effects of Xe Gas Content and Total Gas Pressure on the Discharge Characteristics of Colour Plasma Display Panels

    International Nuclear Information System (INIS)

    Hu Wenbo; Han Mengju; Liang Zhihu

    2006-01-01

    The effects of the Xe gas content and total gas pressure on the discharge characteristics of colour plasma display panels including the sustaining voltage margin, white-field chromaticity, discharge time lag (DTL), discharge current peak, and full-width-at-half-maximum (FWHM) of the discharge current pulse, are experimentally studied. The results indicate that as the Xe gas content in the He-Ne-Xe gas mixture or total pressure increases, the sustaining voltage margin increases, the white-field chromaticity improves, and the discharge current peak has a maximum value, while DTL and FWHM have a minimum value. The mean electron energy in the gas mixture discharge is also calculated through a numerical solution of Boltzmann equation. The experimental results are explained from a view of the mean electron energy variations with the Xe gas content and total gas pressure

  2. Alcohol, cognitive impairment and the hard to discharge acute hospital inpatients.

    LENUS (Irish Health Repository)

    Popoola, A

    2012-02-03

    AIM: To examine the role of alcohol and alcohol-related cognitive impairment in the clinical presentation of adults in-patients less than 65 years who are \\'hard to discharge\\' in a general hospital. METHOD: Retrospective medical file review of inpatients in CUH referred to the discharge coordinator between March and September 2006. RESULTS: Of 46 patients identified, the case notes of 44 (25 male; age was 52.2 +\\/- 7.7 years) were reviewed. The average length of stay in the hospital was 84.0 +\\/- 72.3 days and mean lost bed days was 15.9 +\\/- 36.6 days. The number of patients documented to have an overt alcohol problem was 15 (34.1%). Patients with alcohol problems were more likely to have cognitive impairment than those without an alcohol problem [12 (80%) and 9 (31%) P = 0.004]. Patients with alcohol problems had a shorter length of stay (81.5 vs. 85.3 days; t = 0.161, df = 42, P = 0.87), fewer lost bed days (8.2 vs. 19.2 days; Mann-Whitney U = 179, P = 0.34) and no mortality (0 vs. 6) compared with hard to discharge patients without alcohol problem. CONCLUSION: Alcohol problems and alcohol-related cognitive impairment are hugely over-represented in acute hospital in-patients who are hard to discharge. Despite these problems, this group appears to have reduced morbidity, less lost bed days and a better outcome than other categories of hard to discharge patients. There is a need to resource acute hospitals to address alcohol-related morbidity in general and Wernicke-Korsakoff Syndrome in particular.

  3. Coal-fired power plant: airborne routine discharges

    International Nuclear Information System (INIS)

    Zeevaert, T.

    2005-01-01

    The radiological impact from non-nuclear industries is a growing matter of concern to stake holders and regulators. It has been demonstrated that atmospheric discharges from coal-fired power plants can lead to higher dose-impacts to critical groups of the population than nuclear power plants. In Belgium, in the frame of an agreement between electricity producers and national authorities, measures were taken in conventional power plants to restrict airborne discharges of SO 2 , NO x and suspended particles. In the 500 MWe coal-fired power plant of Langerlo, a flue gas purification system was installed, consisting of a denitrification unit and a desulphurization unit, next to the electrostatic dust filter units. These measures have also an important effect on the radioactive atmospheric discharges. The objective of this study was to assess the radiological impact of the airborne releases of the power plant under normal working conditions and in particular the influence of the installation of the flue gas purification system. As a first step, we measured the natural radioactivity content of the coal and the radium content of the fly ash . The quantities of the other radioelements discharged through the chimney, were estimated, assuming the same behaviour as radium, except for the more volatile lead and polonium, which will condense preferably on finer ash particles, against which the electro filters are less effective. (A concentration factor of 4 has been adopted). The radon, present in the coal, is assumed to be discharged completely through the chimney. The atmospheric transport, dispersion and deposition of the discharged radionuclides were modelled, applying the bi-Gaussian plume model IFDM. For the calculations, we used hourly averages of the meteorological observations at Mol over the year 1991. The transfers of the radionuclides from air and soil to the biospheric media, exposing man, were calculated with our biosphere model and the radiological impact to the

  4. 'Delayed discharges and boarders': a 2-year study of the relationship between patients experiencing delayed discharges from an acute hospital and boarding of admitted patients in a crowded ED.

    Science.gov (United States)

    Mustafa, Farah; Gilligan, Peadar; Obu, Deborah; O'Kelly, Patrick; O'Hea, Eimear; Lloyd, Catherine; Kelada, Sherif; Heffernan, Attracta; Houlihan, Patricia

    2016-09-01

    Many believe that hospital crowding manifesting in the ED with the boarding of admitted patients is a result of significant numbers of acute hospital beds being occupied by patients awaiting discharge to nursing homes, step-down facilities or home with or without additional support. This observational study was performed to establish the actual relationship between boarders in the ED and patients experiencing delayed discharge. Data relating to the number of patients in the ED and their points in their patient pathway were entered into a logbook on a daily basis by the most senior doctor on duty. 630 days of observations of patients boarded in the ED were compared with the number of inpatients with delayed discharges, obtained from the hospital information system, to see if large numbers of inpatients with delayed discharges are associated with crowding in the ED. Two years of data showed an annual ED census of more than 47 000, with a daily mean ED admission rate of 29.85 patients and a daily mean ED boarding figure of 29 patients. A mean of 15.4% of the 823 hospital beds was occupied by patients with delayed discharges, and the hospital ran at, or near, full capacity (99%-105%) all the time. Results obtained highlighted a statistically significant relationship between delayed discharges in the hospital and ED crowding as a result of boarders (p value<0.001, with a regression coefficient of 0.16, 95% CI 0.12 to 0.20). The study also showed that the number of boarders was related to the number of ED admissions in the preceding 24 hours (p=0.036, with a regression coefficient of 0.14, 95% CI 0.05 to 0.28). Delayed hospital discharges significantly contribute to crowding in the ED. Healthcare systems should target timely discharge of inpatients experiencing delayed discharge in an urgent and efficient manner to improve timely access to acute hospital beds for patients requiring emergency admission. Published by the BMJ Publishing Group Limited. For permission

  5. The Post-Discharge Network Coordination Programme (PDNC-P: A randomised controlled trial to evaluate the efficacy of an intervention aimed at reducing rehospitalisations and improving mental health

    Directory of Open Access Journals (Sweden)

    Michael Pascal Hengartner

    2016-03-01

    Full Text Available Purpose: To evaluate the efficacy of a post-discharge intervention for psychiatric inpatients aimed at preventing hospital readmissions and at improving patients’ mental health and psychosocial functioning. Methods: RCT using parallel group block randomisation including 151 patients with ≤3 hospitalisations within the last three years, a GAF score ≤60, and aged 18–64 years, assessed at two psychiatric hospitals from the canton of Zurich, Switzerland, between September 2011 and February 2014. Primary outcomes were rate and duration of rehospitalisation; secondary outcomes were mental health and functioning. Outcome measures were assessed before discharge from the index hospitalisation (t0, 3 months after discharge when the intervention terminated (t1, and 12 months after discharge (t2. Participants received either a brief case management post-discharge intervention or treatment as usual.Results: In the short-term (i.e., t0-t1 no significant effect emerged in any outcome. In the long-term (i.e., t0-t2 the two groups did not differ significantly with respect to the rate and duration of rehospitalisation. Also, the intervention did not reduce psychiatric symptoms, did not improve social support and did not improve quality of life. However, it did slightly increase assessor-rated general (d=0.30 and social functioning (d=0.42, although self-reports revealed a deteriorative effect on symptom remission (d=-0.44.Conclusions: This psychosocial post-discharge intervention showed no efficacy in the primary outcome of rehospitalisation. With respect to secondary outcomes, in the long-term it might lead to slightly increased social functioning but revealed no significant effect on psychopathology, social support and quality of life. In contrast, with respect to self-reported symptom remission, it was revealed to have a negative effect. In this high-resource catchment area with comprehensive community psychiatric and social services the intervention

  6. Comparison of high-voltage ac and pulsed operation of a surface dielectric barrier discharge

    Science.gov (United States)

    Williamson, James M.; Trump, Darryl D.; Bletzinger, Peter; Ganguly, Biswa N.

    2006-10-01

    A surface dielectric barrier discharge (DBD) in atmospheric pressure air was excited either by low frequency (0.3-2 kHz) high-voltage ac or by short, high-voltage pulses at repetition rates from 50 to 600 pulses s-1. The short-pulse excited discharge was more diffuse and did not have the pronounced bright multiple cathode spots observed in the ac excited discharge. The discharge voltage, current and average power deposited into the discharge were calculated for both types of excitation. As a measure of plasma-chemical efficiency, the ozone number density was measured by UV absorption as a function of average deposited power. The density of ozone produced by ac excitation did not increase so rapidly as that produced by short-pulse excitation as a function of average power, with a maximum measured density of ~3 × 1015 cm-3 at 25 W. The maximum ozone production achieved by short-pulse excitation was ~8.5 × 1015 cm-3 at 20 W, which was four times greater than that achieved by ac excitation at the same power level.

  7. Twenty-five years of maximum-entropy principle

    Science.gov (United States)

    Kapur, J. N.

    1983-04-01

    The strengths and weaknesses of the maximum entropy principle (MEP) are examined and some challenging problems that remain outstanding at the end of the first quarter century of the principle are discussed. The original formalism of the MEP is presented and its relationship to statistical mechanics is set forth. The use of MEP for characterizing statistical distributions, in statistical inference, nonlinear spectral analysis, transportation models, population density models, models for brand-switching in marketing and vote-switching in elections is discussed. Its application to finance, insurance, image reconstruction, pattern recognition, operations research and engineering, biology and medicine, and nonparametric density estimation is considered.

  8. aetiological agents of ear discharge: a two year re- view in a ...

    African Journals Online (AJOL)

    2014-06-01

    Jun 1, 2014 ... SUMMARY. Background: The discharging ear is a common presentation in medical practice affecting all age groups but primarily children. This study shows the current aetiological causes of ear discharge and their antibiograms, data which would guide empirical treat- ment of ear infections, and also form ...

  9. Synthesis of pure ozone by nanosecond discharge at cryogenic temperatures

    International Nuclear Information System (INIS)

    Amirov, R.H.; Asinovsky, E.I.; Samoilov, I.S.

    1996-01-01

    Synthesis of pure ozone by nanosecond discharge at cryogenic temperatures was experimentally examined. The average ozone concentration in the volume of the discharge tube was less at cryogenic temperatures than at room temperatures. The production of condensed ozone have been determined by measuring the ozone concentration when the walls was heated and ozone evaporated. The energy yield of ozone generation at cryogenic temperatures has been calculated. The maximum value was 200 g/kWh

  10. Weak scale from the maximum entropy principle

    Science.gov (United States)

    Hamada, Yuta; Kawai, Hikaru; Kawana, Kiyoharu

    2015-03-01

    The theory of the multiverse and wormholes suggests that the parameters of the Standard Model (SM) are fixed in such a way that the radiation of the S3 universe at the final stage S_rad becomes maximum, which we call the maximum entropy principle. Although it is difficult to confirm this principle generally, for a few parameters of the SM, we can check whether S_rad actually becomes maximum at the observed values. In this paper, we regard S_rad at the final stage as a function of the weak scale (the Higgs expectation value) vh, and show that it becomes maximum around vh = {{O}} (300 GeV) when the dimensionless couplings in the SM, i.e., the Higgs self-coupling, the gauge couplings, and the Yukawa couplings are fixed. Roughly speaking, we find that the weak scale is given by vh ˜ T_{BBN}2 / (M_{pl}ye5), where ye is the Yukawa coupling of electron, T_BBN is the temperature at which the Big Bang nucleosynthesis starts, and M_pl is the Planck mass.

  11. Predicting tile drainage discharge

    DEFF Research Database (Denmark)

    Iversen, Bo Vangsø; Kjærgaard, Charlotte; Petersen, Rasmus Jes

    used in the analysis. For the dynamic modelling, a simple linear reservoir model was used where different outlets in the model represented tile drain as well as groundwater discharge outputs. This modelling was based on daily measured tile drain discharge values. The statistical predictive model...... was based on a polynomial regression predicting yearly tile drain discharge values using site specific parameters such as soil type, catchment topography, etc. as predictors. Values of calibrated model parameters from the dynamic modelling were compared to the same site specific parameter as used...

  12. Ideal ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Galvao, R.M.O.; Lazzaro, E.; O'Rourke, J.; Smeulders, P.; Schmidt, G.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, discharges with β approaching the Troyon-Sykes-Wesson critical value β c for optimised pressure profiles have been produced at low toroidal fields (B T =1.5T). In the second type, extremely high pressure gradients have been produced in the plasma core through pellet injection in the current rise phase of the discharge followed by strong additional heating. The stability of these discharges has been studied with the stability code HBT coupled to the equilibrium identification code IDENTC. The equilibrium pressure and diamagnetic function profiles are determined in IDENTC by an optimisation procedure to fit the external magnetic measurements. The resulting pressure profile in the equatorial plane is then compared with the profile derived from 'direct' measurements, i.e. electron density and temperature profiles measured by the LIDAR diagnostic system, ion-temperature profile measured by the charge-exchange diagnostic system, and ion density profile calculated from the Z eff and electron density profiles. Furthermore, the value of the safety factor q on axis is compared with that determined from polarimetry. When good agreement is found, the output data from IDENTC is passed directly to HBT to carry out the stability analysis. When there is not a good agreement, as in the case of pellet discharges with highly peaked pressure profiles, the equilibrium is reevaluated using the 'experimental' profile and the data from polarimetry. (author) 6 refs., 4 figs

  13. Current Trends in Discharge Disposition and Post-discharge Care After Total Joint Arthroplasty.

    Science.gov (United States)

    Tarity, T David; Swall, Marion M

    2017-09-01

    The purpose of this manuscript is to review published literature over the last 5 years to assess recent trends and influencing factors regarding discharge disposition and post-discharge care following total joint arthroplasty. We evaluated instruments proposed to predict a patient's discharge disposition and summarize reports investigating the safety in sending more patients home by reviewing complications and readmission rates. Current literature supports decreased length of hospital stay and increased discharge to home with cost savings and stable readmission rates. Surgeons with defined clinical pathways and those who shape patient expectations may more effectively control costs than those without defined pathways. Further research is needed analyzing best practices in care coordination, managing patient expectations, and cost-effective analysis of home discharge while at the same time ensuring patient outcomes are optimized following total joint arthroplasty.

  14. Discharge Dialogue

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    2012-01-01

    For several years, efforts have been made to strengthen collaboration between health professionals with different specializations and to improve patient transition from hospital to home (care). In the Danish health care system, these efforts have concentrated on cancer and heart diseases, whereas...... coordinator, employed at the hospital, is supposed to anticipate discharge and serve as mediator between the hospital and the municipal home care system. Drawing on methods from discourse and interaction analysis, the paper studies the practice of the discharge coordinator in two encounters between patients...... how the home context provides different resources for identification of patient needs and mutual decision making....

  15. Correlation of shoulder range of motion limitations at discharge with limitations in activities and participation one year later in persons with spinal cord injury.

    Science.gov (United States)

    Eriks-Hoogland, Inge E; de Groot, Sonja; Post, Marcel W M; van der Woude, Lucas H V

    2011-02-01

    To study the correlation between limited shoulder range of motion in persons with spinal cord injury at discharge and the performance of activities, wheeling performance, transfers and participation one year later. Multicentre prospective cohort study. A total of 146 newly injured subjects with spinal cord injury. Shoulder range of motion was measured at discharge. One year later, Functional Independence Measure (FIM), transfer ability, wheelchair circuit and Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) were assessed. Corrections were made for possible confounding factors (age, gender, level and completeness of injury, time since injury and shoulder pain). All subjects with limited shoulder range of motion at discharge had a lower FIM motor score and were less likely (total group 5 times, and subjects with tetraplegia 10 times less likely) to be able to perform an independent transfer one year later. Subjects with limited shoulder range of motion in the total group needed more time to complete the wheelchair circuit. No significant associations with the PASIPD were found in either group. Persons with spinal cord injury and limited shoulder range of motion at discharge are more limited in their activities one year later than those without limited shoulder range of motion.

  16. Characterization of the Novillo Tokamak in main discharge regime

    International Nuclear Information System (INIS)

    Lopez C, R.; Melendez L, L.; Chavez A, E.; Colunga S, S.; Valencia A, R.; Gaytan G, E.

    1992-07-01

    The analytical procedure to carry out the establishment of the discharge in a Tokamak including: a) Ionization, b) Diffusion losses, recombination, union, drift speed, spurious fields, and c) Electric field is presented. In an experimental way a procedure settles down by means of which it is characterized the plasma, specially a new characteristic discharge parameter is settled down and it is the plasma current by the duration of the (I p t) discharge. (Author)

  17. Vertical pellet injection in FTU discharges

    International Nuclear Information System (INIS)

    Giovannozzi, E.; Annibaldi, S.V.; Buratti, P.

    2005-01-01

    Central fuelling and pellet enhanced performance modes have been obtained with pellets injected vertically from the high field side on the FTU tokamak. Four phases have been recognized: ablation of the pellets, drifting plasmoids, MHD modes which take the density to the centre of the discharge and finally an anomalous drift which further increases the density peaking. Pellet ablation data have been compared with values from a pellet ablation and deposition code. Comparison between 0.8 and 1.1 MA discharges at a high magnetic field (B T = 7 T) has been carried out: a higher performance has been obtained with the latter due to the higher target density and the larger inversion radius which would increase the effects of m = 1 modes to take the density to the plasma centre

  18. Investigation of airflow effects on the dielectric barrier discharge with single/double discharge channel arrangement

    Science.gov (United States)

    Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng

    2018-05-01

    Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.

  19. Compact continuous HF microwave-discharge mixing laser

    International Nuclear Information System (INIS)

    Gagne, J.M.; Bertrand, L.; Conturie, Y.; Mah, S.Q.; Monchalin, J.P.

    1975-01-01

    The performance of a continuous chemical laser is discussed. Fluorine atoms are produced in a SF 6 + He mixture by means of a microwave-discharge apparatus that operates in a continuous mode. A maximum output power of 4 W is obtained for a 5 cm length of amplifying medium; this power output is primarily due to P transitions from the 1-0 and 2-1 bands. Weak transitions in the 3-2 band are also observed. The maximum value of measured gain is 0.11 cm -1 ; good agreement is obtained between theoretical and experimental values of gain. (auth)

  20. Electrical discharge occurring between a negatively charged particle cloud and a grounded sphere electrode

    International Nuclear Information System (INIS)

    Higashiyama, Y; Migita, S; Toki, K; Sugimoto, T

    2008-01-01

    Electrostatic discharge occurring between a space-charge cloud and a grounded object was investigated using a large-scale charged particle cloud formed by using three set of cloud generators consisting of a blower and corona charger. The ejecting velocity of the particles affects the formation of the charged cloud. At the lower velocity, the charged cloud spread due to electrostatic repulsion force, while at the higher velocity cloud forms an elongated conical shape. To cause electrostatic discharge between the cloud and a grounded object, a grounded sphere electrode with 100 mm in diameter was set at the inside or outside of the cloud. The brush-like discharge channels reached the maximum length of 0.55 m. The discharge current has a waveform with single or multi-peak, a current peak of several amperes, the maximum charge quantity of 2 μC, and the duration of several microseconds. The relationship between the charge quantity and the current peak or the duration in each discharge was examined. The discharge between the cloud and the electrode placed at the outside of the cloud has relatively longer channels and multi-peak current with the longer duration, while that at the inside of the cloud has the lower charge quantity with single peak.

  1. Ramp discharge in Z-pinch

    Energy Technology Data Exchange (ETDEWEB)

    Gaber, W.H.; Beshara, A.B.; El-Bialy, A.B.; Masoud, M.M. [Plasma and Nuclear Fusion Dept., N.R.C., Atomic Energy Authority, Enshass (Egypt)

    2004-07-01

    A ramp Z-pinch discharge is designed and built in order to increase the pinch ratio and obtain a maximum contraction, and to increase the temperature. The discharge chamber is a cylindrical Pyrex tube of 25 cm long, 18.5 cm, 20 cm inner and outer diameter and two circular Aluminum plates of radius 15 cm separated by 21 cm are inserted into the tube. The tube is filled with He gas at 0.1 mbar. Two capacitor banks are used, the first bank 30 {mu}F and the second fast bank 1.3 {mu}F. The charging voltage was 8 kV for both banks. The discharge current and voltage of each bank are measured by potential divider and Rogowski coil respectively. Also the plasma inductance and resistance are obtained for each case. The plasma inductance has its peak value 300 nH at 4 {mu}s, while the plasma resistance has it minimum 8 m{omega} at the same time in the case of conventional discharge (single bank). In the case of ramp discharge, the inductance has two peaks 440 nH, 380 nH at 4 {mu}s, 9.5 {mu}s respectively, while the resistance has two minimum 4 m{omega}, 20 m{omega} at at 4 {mu}s, 9.5 {mu}s respectively. The temperature has been measure spectroscopically by using relative continuum intensity ratio method. The temperature has its peak value 38 eV at 4 {mu}s for single bank case, while it larger peak value 55 eV for ramp case. (orig.)

  2. New shower maximum trigger for electrons and photons at CDF

    International Nuclear Information System (INIS)

    Gerdes, D.

    1994-08-01

    For the 1994 Tevatron collider run, CDF has upgraded the electron and photon trigger hardware to make use of shower position and size information from the central shower maximum detector. For electrons, the upgrade has resulted in a 50% reduction in backgrounds while retaining approximately 90% of the signal. The new trigger also eliminates the background to photon triggers from single-phototube discharge

  3. Optimum Discharge Burnup and Cycle Length for PWRs

    International Nuclear Information System (INIS)

    Secker, Jeffrey R.; Johansen, Baard J.; Stucker, David L.; Ozer, Odelli; Ivanov, Kostadin; Yilmaz, Serkan; Young, E.H.

    2005-01-01

    This paper discusses the results of a pressurized water reactor fuel management study determining the optimum discharge burnup and cycle length. A comprehensive study was performed considering 12-, 18-, and 24-month fuel cycles over a wide range of discharge burnups. A neutronic study was performed followed by an economic evaluation. The first phase of the study limited the fuel enrichments used in the study to 235 U consistent with constraints today. The second phase extended the range of discharge burnups for 18-month cycles by using fuel enriched in excess of 5 wt%. The neutronic study used state-of-the-art reactor physics methods to accurately determine enrichment requirements. Energy requirements were consistent with today's high capacity factors (>98%) and short (15-day) refueling outages. The economic evaluation method considers various component costs including uranium, conversion, enrichment, fabrication and spent-fuel storage costs as well as the effect of discounting of the revenue stream. The resulting fuel cycle costs as a function of cycle length and discharge burnup are presented and discussed. Fuel costs decline with increasing discharge burnup for all cycle lengths up to the maximum discharge burnup considered. The choice of optimum cycle length depends on assumptions for outage costs

  4. Westinghouse Hanford Company effluent discharges and solid waste management report for calendar year 1989: 200/600 Areas

    International Nuclear Information System (INIS)

    Brown, M.J.; P'Pool, R.K.; Thomas, S.P.

    1990-05-01

    This report presents calendar year 1989 radiological and nonradiological effluent discharge data from facilities in the 200 Areas and the 600 Area of the Hanford Site. Both summary and detailed effluent data are presented. In addition, radioactive and nonradioactive solid waste storage and disposal data for calendar year 1989 are furnished. Where appropriate, comparisons to previous years are made. The intent of the report is to demonstrate compliance of Westinghouse Hanford Company-operated facilities with administrative control values for radioactive constituents and applicable guidelines and standards (including Federal permit limits) for nonradioactive constituents. 11 refs., 20 tabs

  5. Reference values of maximum walking speed among independent community-dwelling Danish adults aged 60 to 79 years

    DEFF Research Database (Denmark)

    Tibaek, S; Holmestad-Bechmann, N; Pedersen, Trine B

    2015-01-01

    OBJECTIVES: To establish reference values for maximum walking speed over 10m for independent community-dwelling Danish adults, aged 60 to 79 years, and to evaluate the effects of gender and age. DESIGN: Cross-sectional study. SETTING: Danish companies and senior citizens clubs. PARTICIPANTS: Two ...

  6. Charged particle emission effects on the characteristics of glow discharges with oscillating electrons

    CERN Document Server

    Nikulin, S P

    2001-01-01

    One discusses the effect of selection of charged particles on conditions to maintain and the characteristics of a glow discharge with oscillating electrons. It is shown that there is a pressure dependent optimal level of ion selection when the energy efficiency of ion source reaches its maximum value. It is determined that departure of fast ionizing electrons affects negatively the discharge maintenance wile emission of slow plasma electrons may promote maintenance of a discharge high current shape. It is shown that high efficient electron emission without violation of a discharge stability may take place in a magnetic field due to different nature of spatial distributions of fast and slow particles in discharges with electron oscillation

  7. Comparison of high-voltage ac and pulsed operation of a surface dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, James M [Innovative Scientific Solutions, Inc., 2766 Indian Ripple Road, Dayton, Ohio 45440-3638 (United States); Trump, Darryl D [Innovative Scientific Solutions, Inc., 2766 Indian Ripple Road, Dayton, Ohio 45440-3638 (United States); Bletzinger, Peter [Innovative Scientific Solutions, Inc., 2766 Indian Ripple Road, Dayton, Ohio 45440-3638 (United States); Ganguly, Biswa N [Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433-7919 (United States)

    2006-10-21

    A surface dielectric barrier discharge (DBD) in atmospheric pressure air was excited either by low frequency (0.3-2 kHz) high-voltage ac or by short, high-voltage pulses at repetition rates from 50 to 600 pulses s{sup -1}. The short-pulse excited discharge was more diffuse and did not have the pronounced bright multiple cathode spots observed in the ac excited discharge. The discharge voltage, current and average power deposited into the discharge were calculated for both types of excitation. As a measure of plasma-chemical efficiency, the ozone number density was measured by UV absorption as a function of average deposited power. The density of ozone produced by ac excitation did not increase so rapidly as that produced by short-pulse excitation as a function of average power, with a maximum measured density of {approx}3 x 10{sup 15} cm{sup -3} at 25 W. The maximum ozone production achieved by short-pulse excitation was {approx}8.5 x 10{sup 15} cm{sup -3} at 20 W, which was four times greater than that achieved by ac excitation at the same power level.

  8. Comparison of high-voltage ac and pulsed operation of a surface dielectric barrier discharge

    International Nuclear Information System (INIS)

    Williamson, James M; Trump, Darryl D; Bletzinger, Peter; Ganguly, Biswa N

    2006-01-01

    A surface dielectric barrier discharge (DBD) in atmospheric pressure air was excited either by low frequency (0.3-2 kHz) high-voltage ac or by short, high-voltage pulses at repetition rates from 50 to 600 pulses s -1 . The short-pulse excited discharge was more diffuse and did not have the pronounced bright multiple cathode spots observed in the ac excited discharge. The discharge voltage, current and average power deposited into the discharge were calculated for both types of excitation. As a measure of plasma-chemical efficiency, the ozone number density was measured by UV absorption as a function of average deposited power. The density of ozone produced by ac excitation did not increase so rapidly as that produced by short-pulse excitation as a function of average power, with a maximum measured density of ∼3 x 10 15 cm -3 at 25 W. The maximum ozone production achieved by short-pulse excitation was ∼8.5 x 10 15 cm -3 at 20 W, which was four times greater than that achieved by ac excitation at the same power level

  9. Modelling maximum likelihood estimation of availability

    International Nuclear Information System (INIS)

    Waller, R.A.; Tietjen, G.L.; Rock, G.W.

    1975-01-01

    Suppose the performance of a nuclear powered electrical generating power plant is continuously monitored to record the sequence of failure and repairs during sustained operation. The purpose of this study is to assess one method of estimating the performance of the power plant when the measure of performance is availability. That is, we determine the probability that the plant is operational at time t. To study the availability of a power plant, we first assume statistical models for the variables, X and Y, which denote the time-to-failure and the time-to-repair variables, respectively. Once those statistical models are specified, the availability, A(t), can be expressed as a function of some or all of their parameters. Usually those parameters are unknown in practice and so A(t) is unknown. This paper discusses the maximum likelihood estimator of A(t) when the time-to-failure model for X is an exponential density with parameter, lambda, and the time-to-repair model for Y is an exponential density with parameter, theta. Under the assumption of exponential models for X and Y, it follows that the instantaneous availability at time t is A(t)=lambda/(lambda+theta)+theta/(lambda+theta)exp[-[(1/lambda)+(1/theta)]t] with t>0. Also, the steady-state availability is A(infinity)=lambda/(lambda+theta). We use the observations from n failure-repair cycles of the power plant, say X 1 , X 2 , ..., Xsub(n), Y 1 , Y 2 , ..., Ysub(n) to present the maximum likelihood estimators of A(t) and A(infinity). The exact sampling distributions for those estimators and some statistical properties are discussed before a simulation model is used to determine 95% simulation intervals for A(t). The methodology is applied to two examples which approximate the operating history of two nuclear power plants. (author)

  10. Experiments on Ion-Ion Plasmas From Discharges

    Science.gov (United States)

    Leonhardt, Darrin; Walton, Scott; Blackwell, David; Murphy, Donald; Fernsler, Richard; Meger, Robert

    2001-10-01

    Use of both positive and negative ions in plasma processing of materials has been shown to be advantageous[1] in terms of better feature evolution and control. In this presentation, experimental results are given to complement recent theoretical work[2] at NRL on the formation and decay of pulsed ion-ion plasmas in electron beam generated discharges. Temporally resolved Langmuir probe and mass spectrometry are used to investigate electron beam generated discharges during the beam on (active) and off (afterglow) phases in a variety of gas mixtures. Because electron-beam generated discharges inherently[3] have low electron temperatures (<0.5eV in molecular gases), negative ion characteristics are seen in the active as well as afterglow phases since electron detachment increases with low electron temperatures. Analysis of temporally resolved plasma characteristics deduced from these measurements will be presented for pure O_2, N2 and Ar and their mixtures with SF_6. Oxygen discharges show no noticeable negative ion contribution during the active or afterglow phase, presumably due to the higher energy electron attachment threshold, which is well above any electron temperature. In contrast, SF6 discharges demonstrate ion-ion plasma characteristics in the active glow and are completely ion-ion in the afterglow. Comparison between these discharges with published cross sections and production mechanisms will also be presented. [1] T.H. Ahn, K. Nakamura & H. Sugai, Plasma Sources Sci. Technol., 5, 139 (1996); T. Shibyama, H. Shindo & Y. Horiike, Plasma Sources Sci. Technol., 5, 254 (1996). [2] See presentation by R. F. Fernsler, at this conference. [3] D. Leonhardt, et al., 53rd Annual GEC, Houston, TX.

  11. Relaxation of the vibrational distribution function in N2 time varying discharges

    International Nuclear Information System (INIS)

    Capitelli, M.; Gorse, C.; Ricard, A.

    1981-01-01

    Relaxation of the electron and vibrational distribution functions have been calculated in function of residence time in nitrogen electrical discharges and post-discharges. In the discharge the vibrational temperature get bigger with the residence time for t -2 s. In the post-discharge the vibrational distribution is evolving in such a manner that the high levels are overpopulated as the low vibrational level population is dropping

  12. Pressure and gap length dependence of gap breakdown voltage and discharge current of discharge-pumped KrF excimer laser. Hoden reiki KrF laser no zetsuen hakai den prime atsu to reiki denryu no atsuryoku, gap cho izon sei

    Energy Technology Data Exchange (ETDEWEB)

    Yukimura, K.; Kawakami, H. (Doshisha Univ., Tokyo (Japan)); Hitomi, K. (Kyoto Polytechnic College, Kyoto (Japan))

    1991-04-20

    On the gap destruction characteristics of UV-preionized discharge-pumped KrF excimer laser (charge transfer type) and the electric characteristics of the excited discharge, studies were made by changing the pressure (1.5-3 atm) and the discharge gap length (14-21 mm) of the discharge medium. (1) Gap breakdown voltage and the maximum current of the excited discharge give a similarity by a product of pressure and the gap length at the charge volatge. (2) Insulation breakdown of the gap occurs at the wave front of the applied voltage and the breakdown time gets delayed by the decreasing voltage applied. By setting the ionization index at constant value 20, the gap breakdown voltage is estimated at the error within 10%. (3) The relation between the maximum current, pressure and the gap length product changes the characteristics by the charge voltage of the primary condenser. With the result combined with the standardization of voltage/current of the excited discharge, the electric characteristics at the specific pressure and gap length can be readily known. 10 refs., 10 figs.

  13. Prognostic significance of maximum primary tumor diameter in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Liang, Shao-Bo; Deng, Yan-Ming; Zhang, Ning; Lu, Rui-Liang; Zhao, Hai; Chen, Hai-Yang; Li, Shao-En; Liu, Dong-Sheng; Chen, Yong

    2013-01-01

    To evaluate the prognostic value of maximum primary tumor diameter (MPTD) in nasopharyngeal carcinoma (NPC). Three hundred and thirty-three consecutive, newly-diagnosed NPC patients were retrospectively reviewed. Kaplan-Meier analysis and the log-rank test were used to estimate overall survival (OS), failure-free survival (FFS), distant metastasis-free survival (DMFS) and local relapse-free survival (LRFS). Cox proportional hazards regression analysis was used to assess the prognostic value of MPTD. Median follow-up was 66 months (range, 2–82 months). Median MPTD in stage T1, T2, T3 and T4 was 27.9, 37.5, 45.0 and 61.3 mm, respectively. The proportion of T1 patients with a MPTD ≤ 30 mm was 62.3%; 72% and 62.9% of T2 and T3 patients had a MPTD > 30–50 mm, and 83.5% of T4 patients had a MPTD > 50 mm. For patients with a MPTD ≤ 30 mm, > 30–50 mm and > 50 mm, the 5-year OS, FFS, DMFS and LRFS rates were 85.2%, 74.2% and 56.3% (P < 0.001); 87%, 80.7% and 62.8% (P < 0.001); 88.7%, 86.4% and 72.5% (P = 0.003); and 98.2%, 93.2% and 86.3% (P = 0.012), respectively. In multivariate analysis, MPTD was a prognostic factor for OS, FFS and DMFS, and the only independent prognostic factor for LRFS. For T3-T4 patients with a MPTD ≤ 50 mm and > 50 mm, the 5-year OS, FFS and DMFS rates were 70.4% vs. 58.4% (P = 0.010), 77.5% vs. 65.2% (P = 0.013) and 83.6% vs. 73.6% (P = 0.047), respectively. In patients with a MPTD ≤ 30 mm, 5-year LRFS in T1, T2, T3 and T4 was 100%, 100%, 88.9% and 100% (P = 0.172). Our data suggest that MPTD is an independent prognostic factor in NPC, and incorporation of MPTD might lead to a further refinement of T staging

  14. Land use change impacts on discharge analysis using SWAT model at Ciherang Pondok DAM catchment area

    Science.gov (United States)

    Utamahadi, M. A.; Pandjaitan, N. H.; Rau, M. I.

    2018-05-01

    The prompt increase of population influenced the requirement for new regions to fulfill people’s primary needs. Its increased land use change and caused many impacts on the environment, including watersheds as well. Ciherang Pondok DAM catchment area is part of Cisadane watershed and was selected as the research area. This research aimed to analyse the water supply and water discharge change caused by the Urban Planning (RTRW) in 2020. The analysis was conducted using soil and water assessment tools (SWAT) model. Stages of this research were catchment area delineation, HRU identification, calibration and validation of models, and prediction of discharge and water demand. The result showed that RTRW of 2020 increased the maximum discharge of 1.6 m3/s and decreased the minimum discharge of 0.01 m3/s, hence the maximum and minimum discharge ratio increased 0.26% from 2016. Output discharge in 2020 at Ciherang Pondok Dam Catchment Area was classified as well, with discharge of 6.72 – 126.2 m3/s, and could fulfil water demand. For the best result, it is better to use climate data from weather stations inside the study area and it is required an improvement in data archiving system.

  15. Potential efficiencies of open- and closed-cycle CO, supersonic, electric-discharge lasers

    Science.gov (United States)

    Monson, D. J.

    1976-01-01

    Computed open- and closed-cycle system efficiencies (laser power output divided by electrical power input) are presented for a CW carbon monoxide, supersonic, electric-discharge laser. Closed-system results include the compressor power required to overcome stagnation pressure losses due to supersonic heat addition and a supersonic diffuser. The paper shows the effect on the system efficiencies of varying several important parameters. These parameters include: gas mixture, gas temperature, gas total temperature, gas density, total discharge energy loading, discharge efficiency, saturated gain coefficient, optical cavity size and location with respect to the discharge, and supersonic diffuser efficiency. Maximum open-cycle efficiency of 80-90% is predicted; the best closed-cycle result is 60-70%.

  16. Power spectrum of electrical discharges seen on Earth and at Saturn

    International Nuclear Information System (INIS)

    Warwick, J.W.

    1989-01-01

    The author presents a method for deriving the radio spectrum of electrical discharges from the properties of the time series of charges crossing the discharge gap. This result is applied to the observed spectra of both terrestrial lightning and Saturn electrical discharge(s) (SED). SED occurrence and power density are shown to have subtle, yet important, differences from these observables as they have been described in the last 5 years. It is demonstrated that throughout the episode of Voyager 1's (V1) closest approach to Saturn, SED probably occurred continuously in frequency upward at least from the upper limit of Saturn kilometric radiation at about 800 kHz. This is so despite the fact that in the dynamic spectra a strip in time and frequency in which SED do not occur extends in frequency from 1.3 MHz up to the oft-discussed lower limit of SED in the leading edge of the episode of closest approach. The greater power in SED that occurred after V1 closest approach is emphasized: it is shown to be consistent with the lower frequency of the maximum in their power spectra. The variable gap length factor is also invoked to explain the variable frequency cutoff in the range 5-15 MHz of the episodes before closest approach. The SED source moved along a single arc defining both preencounter and postencounter events. The discharge gap lengths were a continuous function of position along this arc, with the shortest gaps lying about 5 degree west (as seen from the spacecraft) of the noon meridian of Saturn and the longest gaps lying on the nightside of the planet

  17. Ground-water discharge determined from measurements of evapotranspiration, other available hydrologic components, and shallow water-level changes, Oasis Valley, Nye County, Nevada

    International Nuclear Information System (INIS)

    Reiner, S.R.; Laczniak, R.J.; DeMeo, G.A.; Smith LaRue, J.; Elliott, P.E.; Nylund, W.E.; Fridrich, C.J.

    2002-01-01

    component of 0.5 foot, is estimated to be about 6,000 acre-feet. Annual subsurface outflow from Oasis Valley into the Amargosa Desert is estimated to be between 30 and 130 acre-feet. Estimates of total annual ground-water withdrawal from Oasis Valley by municipal and non-municipal users in 1996 and 1999 are 440 acre-feet and 210 acre-feet, respectively. Based on these values, natural annual ground-water discharge from Oasis Valley is about 6,100 acre-feet. Total annual discharge was 6,500 acre-feet in 1996 and 6,300 acre-feet in 1999. This quantity of natural ground-water discharge from Oasis Valley exceeds the previous estimate made in 1962 by a factor of about 2.5. Water levels were measured in Oasis Valley to gain additional insight into the ET process. In shallow wells, water levels showed annual fluctuations as large as 7 feet and daily fluctuations as large as 0.2 foot. These fluctuations may be attributed to water loss associated with evapotranspiration. In shallow wells affected by E T, annual minimum depths to water generally occurred in winter or early spring shortly after daily ET reached minimum rates. Annual maximum depths to water generally occurred in late summer or fall shortly after daily ET reached maximum rates. The magnitude of daily water-level fluctuations generally increased as ET increased and decreased as depth to water increased

  18. X-ray emission from a nanosecond-pulse discharge in an inhomogeneous electric field at atmospheric pressure

    International Nuclear Information System (INIS)

    Zhang Cheng; Shao Tao; Ren Chengyan; Zhang Dongdong; Tarasenko, Victor; Kostyrya, Igor D.; Ma Hao; Yan Ping

    2012-01-01

    This paper describes experimental studies of the dependence of the X-ray intensity on the anode material in nanosecond high-voltage discharges. The discharges were generated by two nanosecond-pulse generators in atmospheric air with a highly inhomogeneous electric field by a tube-plate gap. The output pulse of the first generator (repetitive pulse generator) has a rise time of about 15 ns and a full width at half maximum of 30–40 ns. The output of the second generator (single pulse generator) has a rise time of about 0.3 ns and a full width at half maximum of 1 ns. The electrical characteristics and the X-ray emission of nanosecond-pulse discharge in atmospheric air are studied by the measurement of voltage-current waveforms, discharge images, X-ray count and dose. Our experimental results showed that the anode material rarely affects electrical characteristics, but it can significantly affect the X-ray density. Comparing the density of X-rays, it was shown that the highest x-rays density occurred in the diffuse discharge in repetitive pulse mode, then the spark discharge with a small air gap, and then the corona discharge with a large air gap, in which the X-ray density was the lowest. Therefore, it could be confirmed that the bremsstrahlung at the anode contributes to the X-ray emission from nanosecond-pulse discharges.

  19. Secondary health conditions in persons with spinal cord injury : A longitudinal study from one to five years post-discharge

    NARCIS (Netherlands)

    Adriaansen, Jacinthe J. E.; Post, Marcel W. M.; de Groot, Sonja; van Asbeck, Floris W. A.; Stolwijk-Swuste, Janneke M.; Tepper, Marga; Lindeman, Eline

    2013-01-01

    Objective: To assess the occurrence of secondary health conditions and their potential risk factors in persons with spinal cord injury from 1 to 5 years after discharge from initial inpatient rehabilitation. Design: Multicentre longitudinal study. Subjects: A total of 139 wheelchair-dependent

  20. The predicted impacts to the groundwater and Columbia River from ammoniated water discharges to the 216-A-36B crib

    International Nuclear Information System (INIS)

    Buelt, J.L.; Conbere, W.; Freshley, M.D.; Hicks, R.J.; Kuhn, W.L.; Lamar, D.A.; Serne, R.J.; Smoot, J.L.

    1988-03-01

    Impact from past and potential future discharges of ammoniated water to the 216-A-36B crib have on groundwater and river concentrations of hazardous chemical constitutents are studied. Until August 1987, the 216-A-36B crib, located in the 200-East Area of the Hanford Site, accepted ammoniated water discharges. Although this study addresses known hazardous chemical constituents associated with such discharges, the primary concern is the discharge of NH 4 OH because of its microbiological conversion to NO 2 /sup /minus// and NO 3 /sup /minus//. As a result of fuel decladding operations, material balance calculations indicate that NH 4 OH has been discharged to the 216-A-36B crib in amounts that exceed reportable quantities under the Comprehensive Environmental Response, Compensation and Liability Act of 1980. Although flow to the crib is relatively constant, the estimated NH 4 OH discharge varies from negligible to a maximum of 10,000 g-molesh. Because these discharges are intermittent, the concentration delivered to the groundwater is a function of soil sorption, microbiological conversion rates of NH 4 + to NO 2 /sup /minus// and NO 3 /sup /minus//, and groundwater dispersion. This report provides results based on the assumptions of maximum, nominal, and discountinued NH 4 OH discharges to the crib. Consequently, the results show maximum and realistic estimates of NH 4 + , NO 2 /sup /minus// and NO 3 /sup /minus// concentrations in the groundwater

  1. Estimating contaminant discharge rates from stabilized uranium tailings embankments

    International Nuclear Information System (INIS)

    Weber, M.F.

    1986-01-01

    Estimates of contaminant discharge rates from stabilized uranium tailings embankments are essential in evaluating long-term impacts of tailings disposal on groundwater resources. Contaminant discharge rates are a function of water flux through tailings covers, the mass and distribution of tailings, and the concentrations of contaminants in percolating pore fluids. Simple calculations, laboratory and field testing, and analytical and numerical modeling may be used to estimate water flux through variably-saturated tailings under steady-state conditions, which develop after consolidation and dewatering have essentially ceased. Contaminant concentrations in water discharging from the tailings depend on tailings composition, leachability and solubility of contaminants, geochemical conditions within the embankment, tailings-water interactions, and flux of water through the embankment. These concentrations may be estimated based on maximum reported concentrations, pore water concentrations, extrapolations of column leaching data, or geochemical equilibria and reaction pathway modeling. Attempts to estimate contaminant discharge rates should begin with simple, conservative calculations and progress to more-complicated approaches, as necessary

  2. Angina - discharge

    Science.gov (United States)

    Chest pain - discharge; Stable angina - discharge; Chronic angina - discharge; Variant angina - discharge; Angina pectoris - discharge; Accelerating angina - discharge; New-onset angina - discharge; Angina-unstable - discharge; ...

  3. Trends of river discharges in Slovenia

    International Nuclear Information System (INIS)

    Ulaga, F; Kobold, M; Frantar, P

    2008-01-01

    Trends of river discharges are very important in recognition of climate changes and also in water management. In last years droughts and floods are more and more frequent, therefore monitoring and investigating of hydrological situation became one of the guidance scientific approach. In analysis of mean annual discharges made in Agency of the Republic of Slovenia for the Environment in last years, statistical significance trend was find out only by rivers of northwest alpine region [1] [2] [3]. In recent research of time changing discharges, presumption of generally decreasing of water quantity all over Slovenia was confirmed. Our basic conclusion - in Slovenia it is well recognized decreasing of water quantity in long period of observation. This fact and also worsening of water quality became alarming problems of our future, especially in dry months of the year.

  4. Methodological aspects of crossover and maximum fat-oxidation rate point determination.

    Science.gov (United States)

    Michallet, A-S; Tonini, J; Regnier, J; Guinot, M; Favre-Juvin, A; Bricout, V; Halimi, S; Wuyam, B; Flore, P

    2008-11-01

    Indirect calorimetry during exercise provides two metabolic indices of substrate oxidation balance: the crossover point (COP) and maximum fat oxidation rate (LIPOXmax). We aimed to study the effects of the analytical device, protocol type and ventilatory response on variability of these indices, and the relationship with lactate and ventilation thresholds. After maximum exercise testing, 14 relatively fit subjects (aged 32+/-10 years; nine men, five women) performed three submaximum graded tests: one was based on a theoretical maximum power (tMAP) reference; and two were based on the true maximum aerobic power (MAP). Gas exchange was measured concomitantly using a Douglas bag (D) and an ergospirometer (E). All metabolic indices were interpretable only when obtained by the D reference method and MAP protocol. Bland and Altman analysis showed overestimation of both indices with E versus D. Despite no mean differences between COP and LIPOXmax whether tMAP or MAP was used, the individual data clearly showed disagreement between the two protocols. Ventilation explained 10-16% of the metabolic index variations. COP was correlated with ventilation (r=0.96, P<0.01) and the rate of increase in blood lactate (r=0.79, P<0.01), and LIPOXmax correlated with the ventilation threshold (r=0.95, P<0.01). This study shows that, in fit healthy subjects, the analytical device, reference used to build the protocol and ventilation responses affect metabolic indices. In this population, and particularly to obtain interpretable metabolic indices, we recommend a protocol based on the true MAP or one adapted to include the transition from fat to carbohydrate. The correlation between metabolic indices and lactate/ventilation thresholds suggests that shorter, classical maximum progressive exercise testing may be an alternative means of estimating these indices in relatively fit subjects. However, this needs to be confirmed in patients who have metabolic defects.

  5. Galactography in non-lactating nipple discharge

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Myung Ok; Lee, Joo Mi; Moon, Jang Ho; Kang, Ik Won; Chung, Soo Young; Bae, Sang Hoon; Park, Soo Sung [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1988-08-15

    Nipple discharge in non-lactating breast is classified as 2 groups. The first group is stagnation discharge which is determined by an apocrino-like exfoliation and stagnation within the ductal system. The second group is hyperplastic or neoplastic group. The secretory breast disease combined with nipple discharge can not be diagnosed by simple X-ray mammography of ultrasonography. For differential diagnosis of secretory breast disease and for localization of lesions, the galactography is necessary. We analysed 49 cases of galactography is non-lactating breat and obtained following results. 1. The most common cause of discharge was duct ectasis (39%) in stagnation discharge group and papilloma (23%) in hyperplastic discharge group. 2. Hyperplastic discharge group occurred most frequently in 5th decade of age and was discovered more frequently in fatty parenchymal pattern on simple mammography. 3. The most frequent type of nipple discharge was cloudy-milky type in stagnation group and bloody nature in hyperplastic group. 4. The most common cause of bloody discharge was papilloma (58%). 5. The bloody nipple discharge among 56 cases of breast cancer during 4 years occurred only in 5 cases (9%)

  6. High-k shallow traps observed by charge pumping with varying discharging times

    International Nuclear Information System (INIS)

    Ho, Szu-Han; Chen, Ching-En; Tseng, Tseung-Yuen; Chang, Ting-Chang; Lu, Ying-Hsin; Lo, Wen-Hung; Tsai, Jyun-Yu; Liu, Kuan-Ju; Wang, Bin-Wei; Cao, Xi-Xin; Chen, Hua-Mao; Cheng, Osbert; Huang, Cheng-Tung; Chen, Tsai-Fu

    2013-01-01

    In this paper, we investigate the influence of falling time and base level time on high-k bulk shallow traps measured by charge pumping technique in n-channel metal-oxide-semiconductor field-effect transistors with HfO 2 /metal gate stacks. N T -V high level characteristic curves with different duty ratios indicate that the electron detrapping time dominates the value of N T for extra contribution of I cp traps. N T is the number of traps, and I cp is charge pumping current. By fitting discharge formula at different temperatures, the results show that extra contribution of I cp traps at high voltage are in fact high-k bulk shallow traps. This is also verified through a comparison of different interlayer thicknesses and different Ti x N 1−x metal gate concentrations. Next, N T -V high level characteristic curves with different falling times (t falling time ) and base level times (t base level ) show that extra contribution of I cp traps decrease with an increase in t falling time . By fitting discharge formula for different t falling time , the results show that electrons trapped in high-k bulk shallow traps first discharge to the channel and then to source and drain during t falling time . This current cannot be measured by the charge pumping technique. Subsequent measurements of N T by charge pumping technique at t base level reveal a remainder of electrons trapped in high-k bulk shallow traps

  7. Five-year biochemical outcome following permanent interstitial brachytherapy for clinical T1-T3 prostate cancer

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Lief, Jonathan H.

    2001-01-01

    Purpose: To evaluate 5-year biochemical disease-free outcome for men with clinical T1b-T3a NxM0 1977 American Joint Committee on Cancer (1997 AJCC) adenocarcinoma of the prostate gland who underwent transperineal ultrasound-guided permanent prostate brachytherapy. Methods and Materials: Four hundred twenty-five patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103 Pd or 125 I, for clinical T1b-T3a NxM0 (1997 AJCC) adenocarcinoma of the prostate gland, from April 1995 to October 1999. No patient underwent pathologic lymph-node staging. One hundred ninety patients were implanted with either 103 Pd or 125 I monotherapy; 235 patients received moderate-dose external beam radiation therapy (EBRT), followed by a prostate brachytherapy boost; 163 patients received neoadjuvant hormonal manipulation, in conjunction with either 103 Pd or 125 I monotherapy (77 patients) or in conjunction with moderate-dose EBRT and a prostate brachytherapy boost (86 patients). The median patient age was 68.0 years (range, 48.2-81.3 years). The median follow-up was 31 months (range, 11-69 months). Follow-up was calculated from the day of implantation. No patient was lost to follow-up. Biochemical disease-free survival was defined by the American Society of Therapeutic Radiation and Oncology (ASTRO) consensus definition. Results: For the entire cohort, the 5-year actuarial biochemical no evidence of disease (bNED) survival rate was 94%. For patients with low-, intermediate-, and high-risk disease, the 5-year biochemical disease-free rates were 97.1%, 97.5%, and 84.4%, respectively. For hormone-naive patients, 95.7%, 96.4%, and 79.9% of patients with low-, intermediate-, and high-risk disease were free of biochemical failure. Clinical and treatment parameters predictive of biochemical outcome included: clinical stage, pretreatment prostate-specific antigen (PSA), Gleason score, risk group, age > 65 years, and neoadjuvant hormonal therapy. Isotope choice was

  8. Investigations of MHD activity in ASDEX discharges

    International Nuclear Information System (INIS)

    Stambaugh, R.; Gernhardt, J.; Klueber, O.; Wagner, F.

    1984-06-01

    This report makes a strong attempt to relate some specific observations of MHD activity in ADEX discharges to observations made on the Doublet III and PDX tokamaks and to theoretical work on high β MHD modes at GA and PPPL. Three topics are discussed. The first topic is the detailed analysis of the time history of MHD activity in a β discharge. The β limit discharge in ASDEX is identified as a discharge in which, during constant neutral beam power, β reaches a maximum and then decreases, often to a lower steady level if the heating pulse is long enough. During the L phase of this discharge, the MHD activity observed in the B coils is both a continuous and bursting coupled m >= 1 mode of the 'fishbone' type. When β is rising in the H phase, this mode disappears; only ELMs are present. At βsub(max), a different mode appears, the m=2, n=1 tearing mode, which grows rapidly as β decreases. The second topic is the very new observation of the fishbone-like mode in a discharge heated by combined neutral beam and ion cyclotron heating power. The mode characteristics are modulated by sawtooth oscillations in a manner consistent with the importance of q(0) in the stability of this mode. The third topic is the search for ELM precursors in discharges designed to have no other competing and complicating MHD activity. In these cases nonaxisymmetric precursors to the Hsub(α) spike were observed. Hence, it appears that an MHD mode, rather than an energy balance problem, must be the origin of the ELM. (orig./GG)

  9. Optimal Portfolio Strategy under Rolling Economic Maximum Drawdown Constraints

    Directory of Open Access Journals (Sweden)

    Xiaojian Yu

    2014-01-01

    Full Text Available This paper deals with the problem of optimal portfolio strategy under the constraints of rolling economic maximum drawdown. A more practical strategy is developed by using rolling Sharpe ratio in computing the allocation proportion in contrast to existing models. Besides, another novel strategy named “REDP strategy” is further proposed, which replaces the rolling economic drawdown of the portfolio with the rolling economic drawdown of the risky asset. The simulation tests prove that REDP strategy can ensure the portfolio to satisfy the drawdown constraint and outperforms other strategies significantly. An empirical comparison research on the performances of different strategies is carried out by using the 23-year monthly data of SPTR, DJUBS, and 3-month T-bill. The investment cases of single risky asset and two risky assets are both studied in this paper. Empirical results indicate that the REDP strategy successfully controls the maximum drawdown within the given limit and performs best in both return and risk.

  10. Recharge Area, Base-Flow and Quick-Flow Discharge Rates and Ages, and General Water Quality of Big Spring in Carter County, Missouri, 2000-04

    Science.gov (United States)

    Imes, Jeffrey L.; Plummer, Niel; Kleeschulte, Michael J.; Schumacher, John G.

    2007-01-01

    Exploration for lead deposits has occurred in a mature karst area of southeast Missouri that is highly valued for its scenic beauty and recreational opportunities. The area contains the two largest springs in Missouri (Big Spring and Greer Spring), both of which flow into federally designated scenic rivers. Concerns about potential mining effects on the area ground water and aquatic biota prompted an investigation of Big Spring. Water-level measurements made during 2000 helped define the recharge area of Big Spring, Greer Spring, Mammoth Spring, and Boze Mill Spring. The data infer two distinct potentiometric surfaces. The shallow potentiometric surface, where the depth-to-water is less than about 250 feet, tends to mimic topographic features and is strongly controlled by streams. The deep potentiometric surface, where the depth-to-water is greater than about 250 feet represents ground-water hydraulic heads within the more mature karst areas. A highly permeable zone extends about 20 mile west of Big Spring toward the upper Hurricane Creek Basin. Deeper flowing water in the Big Spring recharge area is directed toward this permeable zone. The estimated sizes of the spring recharge areas are 426 square miles for Big Spring, 352 square miles for Greer Spring, 290 square miles for Mammoth Spring, and 54 square miles for Boze Mill Spring. A discharge accumulation curve using Big Spring daily mean discharge data shows no substantial change in the discharge pattern of Big Spring during the period of record (water years 1922 through 2004). The extended periods when the spring flow deviated from the trend line can be attributed to prolonged departures from normal precipitation. The maximum possible instantaneous flow from Big Spring has not been adequately defined because of backwater effects from the Current River during high-flow conditions. Physical constraints within the spring conduit system may restrict its maximum flow. The largest discharge measured at Big Spring

  11. [Severe vaginal discharge following rectal surgery].

    Science.gov (United States)

    Burg, L C; Bremers, A J A; Heesakkers, J P F A; Kluivers, K B

    2018-01-01

    Almost 50% of women who have had rectal surgery subsequently develop vaginal discharge. Due to the recurrent and unexpected nature of this heavy discharge, they often experience it as very distressing. Many of these women undergo extensive diagnostic tests that are mainly focused on identifying fistula formation. If no fistula is found, in most cases no other cause for severe vaginal discharge can be demonstrated. In our practice, we saw three patients (49-, 54- and 74-years-old, respectively) with similar severe vaginal discharge after rectal surgery and in whom no explanation for the vaginal discharge could be found. For this reason we conducted a literature search into this condition. Anatomical changes appear to be responsible for heavy vaginal discharge following rectal surgery. Changes in pelvic floor muscles and compression of the distal part of the vagina may lead to pooling of fluid in the proximal part of the vagina, resulting in severe discharge. Symptomatic treatment may reduce the symptoms.

  12. Tonle Sap Lake Water Storage Change Over 24 Years From Satellite Observation and Its Link With Mekong River Discharge and Climate Events

    Science.gov (United States)

    Biancamaria, S.; Frappart, F.; Normandin, C.; Blarel, F.; Bourrel, L.; Aumont, M.; Azema, P.; Vu, P. L.; Lubac, B.; Darrozes, J.

    2017-12-01

    The Tonle Sap lake is the largest freshwater lake in Southeast Asia and is located within the Mekong basin (mainly in Cambodia). It is one of he most productive ecosystem of the world and provide two thirds of Cambodia fish catch. It also plays a unique role on the Mekong basin hydrological cycle: during the monsoon period, the Mekong river partially flows to the lake, whereas during the dry season, the lake flows to the Mekong delta. It is therefore crucial to monitor and take into account this lake to estimate Mekong discharge to the ocean. However, in situ measurements of lake level and river discharge are very sparse (especially during the last decades) and computing lake storage variation from in situ data only is difficult due to the huge annual variation of lake area. That's why, satellite data (nadir radar altimetry and visible imagery) have been used to study its volume variation and its relationship with climate events and Mekong river discharge. Multi-mission altimetry data have been extracted (Topex, ERS-2, ENVISAT, Jason-1, Jason-2, Saral and Jason-3, using CTOH data extraction tools) to derive a lake water level from1993 to 2016, which varies from 3 m to 12 m. Lake area have been computed from MODIS data from 2000 to 2016 and varies from 3,400 km2 to 11,800 km2. These dataset clearly shows a relationship between lake water level and area, which has been used to estimate lake water volume change from 1995 to 2016, with a minimum in 2015 and a maximum in 2011. Lake's droughts and floods can be observed during moderate and strong El Nino/La Nina events, enhanced by the Pacific Decadal Oscillation. Besides, comparison with in situ discharge at the outlet of the Mekong basin (over 1995/2000 time period) shows that lake water level is 20 days time lagged and increases/decreases after Mekong discharge at its outlet. This time lag results of Mekong river partially flowing to the lake. Finally, high correlation between lake level and outlet discharge allows to

  13. The prediction of discharge from in-patient psychiatric rehabilitation: a case-control study

    Directory of Open Access Journals (Sweden)

    Mountain Debbie A

    2011-09-01

    Full Text Available Abstract Background At any time, about 1% of people with severe and enduring mental illness such as schizophrenia require in-patient psychiatric rehabilitation. In-patient rehabilitation enables individuals with the most challenging difficulties to be discharged to successful and stable community living. However, the length of rehabilitation admission that is required is highly variable and the reasons for this are poorly understood. There are very few case-control studies of predictors of outcome following hospitalisation. None have been carried out for in-patient rehabilitation. We aimed to identify the factors that are associated with achieving discharge from in-patient rehabilitation by carrying out a case-control study. Methods We compared two groups: 34 people who were admitted to the Rehabilitation Service at the Royal Edinburgh Hospital and discharged within a six year study period, and 31 people who were admitted in the same period, but not discharged. We compared the groups on demographic, illness, treatment and risk variables that were present at the point of their admission to rehabilitation. We used independent t tests and Pearson Chi-Square tests to compare the two groups. Results We found that serious self harm and suicide attempts, treatment with high dose antipsychotics, antipsychotic polypharmacy and previous care in forensic psychiatric services were all significantly associated with non-discharge. The non-discharged group were admitted significantly later in the six year study period and had already spent significantly longer in hospital. People who were admitted to rehabilitation within the first ten years of developing psychosis were more likely to have achieved discharge. Conclusions People admitted later in the study period required longer rehabilitation admissions and had higher rates of serious self harm and treatment resistant illness. They were also more likely to have had previous contact with forensic services. This

  14. The superfluid diffusion equation S(T)(∂T/∂t) = ∇·[K(T)(∇T)1/3

    International Nuclear Information System (INIS)

    Dresner, L.

    1990-06-01

    This report deals with the superfluid diffusion equation, S(T)(∂T/∂t) = ∇·[K(T)(∇T) 1/3 ], which describes heat transport in turbulent helium-II (superfluid helium). Three methods of solution -- the method of similarity, the variational method, and the method of maximum/minimum principles -- are applied to this equation. The solutions discovered are helpful in addressing the use of helium-II in superconducting magnets and other applications. 22 refs., 23 figs., 3 tabs

  15. Correlation between maximum phonetically balanced word recognition score and pure-tone auditory threshold in elder presbycusis patients over 80 years old.

    Science.gov (United States)

    Deng, Xin-Sheng; Ji, Fei; Yang, Shi-Ming

    2014-02-01

    The maximum phonetically balanced word recognition score (PBmax) showed poor correlation with pure-tone thresholds in presbycusis patients older than 80 years. To study the characteristics of monosyllable recognition in presbycusis patients older than 80 years of age. Thirty presbycusis patients older than 80 years were included as the test group (group 80+). Another 30 patients aged 60-80 years were selected as the control group (group 80-) . PBmax was tested by Mandarin monosyllable recognition test materials with the signal level at 30 dB above the averaged thresholds of 0.5, 1, 2, and 4 kHz (4FA) or the maximum comfortable level. The PBmax values of the test group and control group were compared with each other and the correlation between PBmax and predicted maximum speech recognition scores based on 4FA (PBmax-predict) were statistically analyzed. Under the optimal test conditions, the averaged PBmax was (77.3 ± 16.7) % for group 80- and (52.0 ± 25.4) % for group 80+ (p < 0.001). The PBmax of group 80- was significantly correlated with PBmax-predict (Spearman correlation = 0.715, p < 0.001). The score for group 80+ was less statistically correlated with PBmax-predict (Spearman correlation = 0.572, p = 0.001).

  16. Increased Risk of Vascular Events in Emergency Room Patients Discharged Home with Diagnosis of Dizziness or Vertigo: A 3-Year Follow-Up Study

    Science.gov (United States)

    Lee, Ching-Chih; Ho, Hsu-Chueh; Su, Yu-Chieh; Chiu, Brian C-H; Su, Yung-Cheng; Lee, Yi-Da; Chou, Pesus

    2012-01-01

    Background Dizziness and vertigo symptoms are commonly seen in emergency room (ER). However, these patients are often discharged without a definite diagnosis. Conflicting data regarding the vascular event risk among the dizziness or vertigo patients have been reported. This study aims to determine the risk of developing stroke or cardiovascular events in ER patients discharged home with a diagnosis of dizziness or vertigo. Methodology A total of 25,757 subjects with at least one ER visit in 2004 were identified. Of those, 1,118 patients were discharged home with a diagnosis of vertigo or dizziness. A Cox proportional hazard model was performed to compare the three-year vascular event-free survival rates between the dizziness/vertigo patients and those without dizziness/vertigo after adjusting for confounding and risk factors. Results We identified 52 (4.7%) vascular events in patients with dizziness/vertigo and 454 (1.8%) vascular events in patients without dizziness/vertigo. ER patients discharged home with a diagnosis of vertigo or dizziness had 2-fold (95% confidence interval [CI], 1.35–2.96; pvertigo during the first year. Conclusions ER patients discharged home with a diagnosis of dizziness or vertigo were at a increased risk of developing subsequent vascular events than those without dizziness/vertigo after the onset of dizziness or vertigo. Further studies are warranted for developing better diagnostic and follow-up strategies in increased risk patients. PMID:22558272

  17. Body temperatures of fish feeding in the Point Beach thermal discharge

    International Nuclear Information System (INIS)

    Spigarelli, S.A.; Thommes, M.M.

    1974-01-01

    Between April and November, 1973, measurements of internal body temperature were made on 1310 fish caught by fishermen at the Point Beach Nuclear Plant. Records were also made of fish weight, length, and sex and intake and discharge temperatures. A table is presented to show mean monthly body temperatures and numbers of each species. Approximately 76 percent of the measurements were made on rainbow and brown trout, since these species accounted for 74 percent of the catch. Body temperatures of most fish were intermediate between intake and discharge temperatures. Results suggested that each species has rather specific seasonal temperature requirements and that the maximum discharge temperature was normally avoided by feeding fish

  18. High fusion performance at high T i/T e in JET-ILW baseline plasmas with high NBI heating power and low gas puffing

    Science.gov (United States)

    Kim, Hyun-Tae; Sips, A. C. C.; Romanelli, M.; Challis, C. D.; Rimini, F.; Garzotti, L.; Lerche, E.; Buchanan, J.; Yuan, X.; Kaye, S.; contributors, JET

    2018-03-01

    This paper presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium-deuterium (D-D) fusion neutron rate (~2.8  ×  1016 s-1) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achieved record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i  =  T e. In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i  >  T e can also be attributed to positive feedback between the high T i/T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i/T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. This reveals that particle fuelling played a key role for achieving high T i/T e, and the improved fusion performance.

  19. Incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients.

    Science.gov (United States)

    Ruengorn, Chidchanok; Sanichwankul, Kittipong; Niwatananun, Wirat; Mahatnirunkul, Suwat; Pumpaisalchai, Wanida; Patumanond, Jayanton

    2011-01-01

    The incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients remain uninvestigated in Thailand. To determine incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients. A retrospective cohort study was conducted by reviewing medical charts at Suanprung Psychiatric Hospital, Chiang Mai, Thailand. Mood disorder patients, diagnosed with the International Statistical Classification of Diseases and Related Health Problems 10th Revision codes F31.x, F32.x, and F33.x, who were admitted owing to suicide attempts between October 2006 and May 2009 were eligible. The influence of sociodemographic and clinical risk factors on suicide reattempts was investigated using Cox's proportional-hazards regression analysis. Of 235 eligible mood disorder patients, 36 (15.3%) reattempted suicide (median 109.5 days, range 1-322), seven (3.0%) completed suicide (median 90 days, range 5-185), and 192 (84.2%) neither reattempted nor completed suicide during follow-up. Of all nonfatal suicide reattempts, 14 patients (38.9%) did so within 90 days. Among suicide completers, one (14.3%) did so 5 days after discharge, and four (57.1%) did so within 90 days. The following three risk factors explained 73.3% of the probability of suicide reattempts: over two previous suicide attempts before the index admission (adjusted hazard ratio [HR] 2.48; 95% confidence interval [CI] 1.07-5.76), being concomitantly prescribed typical and atypical antipsychotics (adjusted HR 4.79; 95% CI 1.39-16.52) and antidepressants, and taking a selective serotonin reuptake inhibitor alone (adjusted HR 5.08; 95% CI 1.14-22.75) or concomitantly with norepinephrine and/or serotonin reuptake inhibitors (adjusted HR 6.18; 95% CI 1.13-33.65). Approximately 40% of suicide reattempts in mood disorder patients occurred within 90 days after psychiatric hospital discharge. For mood disorders and when

  20. Measurement of gas temperature and OH density in the afterglow of pulsed positive corona discharge

    International Nuclear Information System (INIS)

    Ono, Ryo; Oda, Tetsuji

    2008-01-01

    The gas temperature and OH density in the afterglow of pulsed positive corona discharge are measured using the laser-induced predissociation fluorescence (LIPF) of OH radicals. Discharge occurs in a 13 mm point-to-plane gap in an atmospheric-pressure H 2 O(2.8%)/O 2 (2.0%)/N 2 mixture. The temperature measurement shows that (i) the temperature increases after discharge and (ii) the temperature near the anode tip (within 1 mm from the anode tip) is much higher than that of the rest of the discharge volume. Near the anode tip, the temperature increases from 500 K (t = 0 μs) to 1100 K (t = 20 μs), where t is the postdischarge time, while it increases from 400 K (t = 0 μs) to 700 K (t = 100 μs) in the rest of the discharge volume away from the anode tip. This temperature difference between the two volumes (near and far from the anode tip) causes a difference in the decay rate of OH density: OH density near the anode tip decays approximately 10 times slower than that far from the tip. The spatial distribution of OH density shows good agreement with that of the secondary streamer luminous intensity. This shows that OH radicals are mainly produced in the secondary streamer, not in the primary one

  1. UK strategy for radioactive discharges 2001-2020. Consultation document

    International Nuclear Information System (INIS)

    2000-06-01

    This consultation draft of a strategy for radioactive discharges describes how the United Kingdom (UK) will implement the agreements reached at the 1998 Ministerial meeting of the OSPAR Commission, with regard to radioactive substances. It also provides a policy base for future reviews of discharge authorisations by the regulatory bodies and for strategic planning by the nuclear operators. The strategy sets a framework for radioactive discharges from UK installations over the next twenty years. Its aims are: progressive and substantial reductions in radioactive discharges from the UK as a whole and from each of the main sectors responsible for such discharges; progressive reduction of human exposure to ionising radiation resulting from radioactive discharges, so that no member of the general public in the UK will be exposed to a dose of more than 0.02 mSv a year, as a result of authorised radioactive discharges made from 2020 onwards; progressive reductions in concentrations of radionuclides in the marine environment resulting from radioactive discharges, such that by 2020 they add close to zero to historic levels. The scope of the UK strategy encompasses radioactive discharges from nuclear licensed sites, defence activities and other nuclear and non-nuclear sources of radioactive discharges. It covers both liquid and aerial discharges, although it is assumed that in general liquid discharges will have the largest and most measurable effects in the marine environment

  2. The basic mobility status upon acute hospital discharge is an independent risk factor for mortality up to 5 years after hip fracture surgery

    DEFF Research Database (Denmark)

    Kristensen, Morten T.; Kehlet, Henrik

    2018-01-01

    Background and purpose — Mortality rates following hip fracture (HF) surgery are high. We evaluated the influence of the basic mobility status on acute hospital discharge to 1- and 5-year mortality rates after HF. Patients and methods — 444 patients with HF ≥60 years (mean age 81 years, 77% women......) being pre-fracture ambulatory and admitted from their own homes, were consecutively included in an in-hospital enhanced recovery program and followed for 5 years. The Cumulated Ambulation Score (CAS, 0–6 points, 6 points equals independence) was used to evaluate the basic mobility status on hospital...... discharge. Results — 102 patients with a CAS stayed in the acute ward a median of 22 (15–32) days post-surgery as compared with a median of 12 (8–16) days for those 342 patients who achieved a CAS =6. Overall 1-year mortality was 16%; in those with CAS

  3. A PIC-MCC code RFdinity1d for simulation of discharge initiation by ICRF antenna

    Science.gov (United States)

    Tripský, M.; Wauters, T.; Lyssoivan, A.; Bobkov, V.; Schneider, P. A.; Stepanov, I.; Douai, D.; Van Eester, D.; Noterdaeme, J.-M.; Van Schoor, M.; ASDEX Upgrade Team; EUROfusion MST1 Team

    2017-12-01

    Discharges produced and sustained by ion cyclotron range of frequency (ICRF) waves in absence of plasma current will be used on ITER for (ion cyclotron-) wall conditioning (ICWC, Te = 3{-}5 eV, ne 18 m-3 ). In this paper, we present the 1D particle-in-cell Monte Carlo collision (PIC-MCC) RFdinity1d for the study the breakdown phase of ICRF discharges, and its dependency on the RF discharge parameters (i) antenna input power P i , (ii) RF frequency f, (iii) shape of the electric field and (iv) the neutral gas pressure pH_2 . The code traces the motion of both electrons and ions in a narrow bundle of magnetic field lines close to the antenna straps. The charged particles are accelerated in the parallel direction with respect to the magnetic field B T by two electric fields: (i) the vacuum RF field of the ICRF antenna E_z^RF and (ii) the electrostatic field E_zP determined by the solution of Poisson’s equation. The electron density evolution in simulations follows exponential increase, {\\dot{n_e} ∼ ν_ion t } . The ionization rate varies with increasing electron density as different mechanisms become important. The charged particles are affected solely by the antenna RF field E_z^RF at low electron density ({ne < 1011} m-3 , {≤ft \\vert E_z^RF \\right \\vert \\gg ≤ft \\vert E_zP \\right \\vert } ). At higher densities, when the electrostatic field E_zP is comparable to the antenna RF field E_z^RF , the ionization frequency reaches the maximum. Plasma oscillations propagating toroidally away from the antenna are observed. The simulated energy distributions of ions and electrons at {ne ∼ 1015} m-3 correspond a power-law Kappa energy distribution. This energy distribution was also observed in NPA measurements at ASDEX Upgrade in ICWC experiments.

  4. Experimental studies of equilibrium in a linear EXTRAP z-pinch discharge

    International Nuclear Information System (INIS)

    Drake, J.R.

    1982-10-01

    Experimental studies of the radial equilibrium condition in linear Extrap discharge have been carried out. Bennet like scaling, NT α I 2 sub (p), has been observed where N is the plasma line density, T is the tempreature and I sub (p) is the plasma discharge current. (Author)

  5. A distributed parameter wire model for transient electrical discharges

    International Nuclear Information System (INIS)

    Maier, W.B. II; Kadish, A.; Sutherland, C.D.; Robiscoe, R.T.

    1990-01-01

    A model for freely propagating transient electrical discharges, such as lightning and punch-through arcs, is developed in this paper. We describe the electromagnetic fields by Maxwell's equations and we represent the interaction of electric fields with the medium to produce current by ∂J/∂t=ω 2 (E-E*J)/4π, where ω and E* are parameters characteristic of the medium, J≡current density, and J≡J/|J|. We illustrate the properties of this model for small-diameter, guided, cylindrically symmetric discharges. Analytic, numerical, and approximate solutions are given for special cases. The model describes, in a new and comprehensive fashion, certain macroscopic discharge properties, such as threshold behavior, quenching and reignition, path tortuosity, discharge termination with nonzero charge density remaining along the discharge path, and other experimentally observed discharge phenomena. Fields, current densities, and charge densities are quantitatively determined from given boundary and initial conditions. We suggest that many macroscopic discharge properties are properly explained by the model as electromagnetic phenomena, and we discuss extensions of the model to include chemistry, principally ionization and recombination

  6. Traveling wave model for laser-guided discharges

    International Nuclear Information System (INIS)

    Lampe, Martin; Fernsler, Richard F.; Slinker, Steven P.; Gordon, Daniel F.

    2010-01-01

    We present an easily solvable 1D traveling wave model for laser-guided discharges. By assuming constant propagation speed u, the hydro/electrodynamic/chemistry equations are reduced to ordinary differential equations in retarded time τ. Negative discharges are shown to propagate only if u>μE b , where μ is electron mobility and E b is the breakdown field; positive discharges propagate only if the channel preconductance exceeds ∼6x10 -11 m/Ω. The axial electric field E is shown to spike up to several times E b and then relax to ∼E b for as long as the gas remains cold. In this streamer region, the channel conductance, current, and potential all increase linearly with τ. The transition to the leader stage, where E is much smaller, occurs in two steps: excitation of vibrational and low-lying electronic states, then gas heating. The propagation range decreases as a function of initial radius and (for given maximum voltage) of the voltage rise rate. Expansion of the hot channel is shown to increase the range.

  7. Is There an Association Between Markers of Cardiovascular Autonomic Dysfunction at Discharge From Rehabilitation and Participation 1 and 5 Years Later in Individuals With Spinal Cord Injury?

    NARCIS (Netherlands)

    Rianne Ravensbergen, H J; de Groot, Sonja; Post, Marcel W; Bongers-Janssen, Helma M; van der Woude, Lucas H; Claydon, Victoria E

    2016-01-01

    OBJECTIVES: To determine whether physical activity and participation 1 and 5 years after discharge are associated with measures of cardiovascular autonomic function: prevalence of hypotension and reduced peak heart rate at discharge from initial inpatient spinal cord injury (SCI) rehabilitation.

  8. Is there an association between markers of cardiovascular autonomic dysfunction at discharge from rehabilitation and participation one and five years later in individuals with spinal cord injury?

    NARCIS (Netherlands)

    Ravensbergen, H.J.C.; De Groot, S.; Post, M.W.M.; Bongers-Janssen, H.M.; van der Woude, L.H.V.; Claydon, V.E.

    Objectives To determine whether physical activity and participation 1 and 5 years after discharge are associated with measures of cardiovascular autonomic function: prevalence of hypotension and reduced peak heart rate at discharge from initial inpatient spinal cord injury (SCI) rehabilitation.

  9. Is there an association between markers of cardiovascular autonomic dysfunction at discharge from rehabilitation and participation one and five years later in individuals with spinal cord injury?

    NARCIS (Netherlands)

    Ravensbergen, H. J. (Rianne); de Groot, Sonja; Post, Marcel W.; Bongers-Janssen, Helma M.; van der Woude, Lucas H.; Claydon, Victoria E.

    Objectives: To determine whether physical activity and participation 1 and 5 years after discharge are associated with measures of cardiovascular autonomic function: prevalence of hypotension and reduced peak heart rate at discharge from initial inpatient spinal cord injury (SCI) rehabilitation.

  10. Location of the valence band maximum in the band structure of anisotropic 1 T'-ReSe2

    Science.gov (United States)

    Eickholt, P.; Noky, J.; Schwier, E. F.; Shimada, K.; Miyamoto, K.; Okuda, T.; Datzer, C.; Drüppel, M.; Krüger, P.; Rohlfing, M.; Donath, M.

    2018-04-01

    Transition-metal dichalcogenides (TMDCs) are a focus of current research due to their fascinating optical and electronic properties with possible technical applications. ReSe2 is an interesting material of the TMDC family, with unique anisotropic properties originating from its distorted 1 T structure (1 T '). To develop a fundamental understanding of the optical and electric properties, we studied the underlying electronic structure with angle-resolved photoemission (ARPES) as well as band-structure calculations within the density functional theory (DFT)-local density approximation (LDA) and GdW approximations. We identified the Γ ¯M¯1 direction, which is perpendicular to the a axis, as a distinct direction in k space with the smallest bandwidth of the highest valence band. Using photon-energy-dependent ARPES, two valence band maxima are identified within experimental limits of about 50 meV: one at the high-symmetry point Z , and a second one at a non-high-symmetry point in the Brillouin zone. Thus, the position in k space of the global valence band maximum is undecided experimentally. Theoretically, an indirect band gap is predicted on a DFT-LDA level, while quasiparticle corrections lead to a direct band gap at the Z point.

  11. Changes in the T2 value of cartilage after meniscus transplantation over 1 year

    International Nuclear Information System (INIS)

    Park, Sun-Young; Lee, Sang Hoon; Lee, Min Hee; Chung, Hye Won; Shin, Myung Jin

    2017-01-01

    To evaluate the changes in the mean T2 values of articular cartilage on serial follow-up images up to 1 year in patients who underwent lateral meniscus allograft transplantation (MAT). Fifty-two patients who underwent lateral MAT surgery at our hospital were evaluated preoperatively and at 2 days, 6 weeks, 3 months, 6 months, and 1 year after MAT using 3.0-T magnetic resonance imaging (MRI) that included T2 mapping. T2 value changes according to the arthroscopic grading of chondromalacia were evaluated in the lateral and medial compartment. Lysholm scores were obtained pre- and postoperatively. The T2 values of cartilage were significantly increased 2 days after operation, and then gradually reduced to the baseline level after 1 year in both compartments. In morphologic assessment performed after 1 year, most areas (92.9 %) showed no interval change of chondromalacia grade. Lyshom knee scores increased significantly from the mean preoperative value of 62.5 (range, 23-95) to 89.7 (range, 64-100) at 1 year (p < 0.001). Mean T2 values of cartilage following MAT exhibited a return to baseline level after 1 year. T2 measurement can be a useful tool for quantitative evaluation of postoperative cartilage changes compared to conventional MRI. (orig.)

  12. Changes in the T2 value of cartilage after meniscus transplantation over 1 year

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun-Young [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Songpa-gu, Seoul (Korea, Republic of); Hallym University Sacred Heart Hospital, Department of Radiology, Anyang-si, Gyeonggi-do (Korea, Republic of); Lee, Sang Hoon; Lee, Min Hee; Chung, Hye Won; Shin, Myung Jin [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Songpa-gu, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate the changes in the mean T2 values of articular cartilage on serial follow-up images up to 1 year in patients who underwent lateral meniscus allograft transplantation (MAT). Fifty-two patients who underwent lateral MAT surgery at our hospital were evaluated preoperatively and at 2 days, 6 weeks, 3 months, 6 months, and 1 year after MAT using 3.0-T magnetic resonance imaging (MRI) that included T2 mapping. T2 value changes according to the arthroscopic grading of chondromalacia were evaluated in the lateral and medial compartment. Lysholm scores were obtained pre- and postoperatively. The T2 values of cartilage were significantly increased 2 days after operation, and then gradually reduced to the baseline level after 1 year in both compartments. In morphologic assessment performed after 1 year, most areas (92.9 %) showed no interval change of chondromalacia grade. Lyshom knee scores increased significantly from the mean preoperative value of 62.5 (range, 23-95) to 89.7 (range, 64-100) at 1 year (p < 0.001). Mean T2 values of cartilage following MAT exhibited a return to baseline level after 1 year. T2 measurement can be a useful tool for quantitative evaluation of postoperative cartilage changes compared to conventional MRI. (orig.)

  13. The effects of power plant passage on zooplankton mortalities: Eight years of study at the Donald C. Cook Nuclear Plant

    International Nuclear Information System (INIS)

    Evans, M.S.; Warren, G.J.; Page, D.I.

    1986-01-01

    Zooplankton mortalities resulting from passage through the Donald C. Cook Nuclear Plant (southeastern Lake Michigan) were studied over an 8-year (1975-1982) period. The power plant operated at a low ΔT ( 0 C) and discharge water temperatures did not exceed 35 0 C (except September 1978). While zooplankton mortalities were significantly greater in discharge than intake waters, differences were small, averaging <3%. There was no evidence of additional delayed effects on zooplankton mortality following plant passage. There was no relationship between zooplankton mortalities and temperature (ΔT, discharge water temperature). Mechanical stresses appeared to be the major cause of zooplankton mortality. The authors hypothesize that fish predation, rather than power plant operation, probably was the major source of zooplankton mortality in inshore waters during much of the year. (author)

  14. Krypton excimer laser oscillation by discharge pumping

    International Nuclear Information System (INIS)

    Shirai, Takahiro; Tabe, Yoshitaka; Kubodera, Shoichi; Sasaki, Wataru; Kawanaka, Junji

    2001-01-01

    We have demonstrated vacuum ultraviolet (VUV) laser oscillation of the krypton excimer (Kr 2 *) excited by a compact self-sustained discharge device. We have observed a spectral narrowing of the Kr 2 * emission centered at 147.8 nm. A deconvoluted spectral width is 0.5 nm (FWHM), which reveals a contrast to a 13 nm spectral width of the spontaneous emission. The Kr 2 * intensity has increased one order of magnitude when a charging voltage was increased larger than 29 kV. The success of the lasing in the VUV spectral region has been attributed to the success of a stable glow discharge of Kr at 10 atm. The pulse width of the VUV laser radiation is 400 ns (FWHM). The maximum output energy measured is as large as 150 μJ. (author)

  15. Space structure of the glow discharge with free side boundary

    International Nuclear Information System (INIS)

    Yatsenko, N.A.

    1995-01-01

    The main purpose of this work is to reveal physical reasons, which are responsible for the formation of space structure of glow type discharge with free side boundary, both in DC and in RF electric fields. By now extensive experimental material have been accumulated in discharge physics. Also many theoretical models have been proposed for describing separate parts of discharge with the cold electrodes (cathode and anode regions, positive column and transition zones - glow luminescence and Farraday's dark space of DC-discharge, electrode regions and plasma column of RF capacitive discharge). As this takes place, the majority of known works are devoted to some one part of gas discharge - positive column, electrode regions, transition zones and so on. At the same time just now we don't know anything about space structure of free, steady-state gas discharge of glow type, as a whole, especially when the pressure p much-gt 1 Torr

  16. Observations of nearshore groundwater discharge: Kahekili Beach Park submarine springs, Maui, Hawaii

    Directory of Open Access Journals (Sweden)

    P.W. Swarzenski

    2017-06-01

    New hydrological insights for the region: Estimates of submarine groundwater discharge were derived for a primary vent site and surrounding coastal waters off west Maui, Hawaii using an excess 222Rn (t1/2 = 3.8 d mass balance model. Such estimates were complemented with a novel thoron (220Rn, t1/2 = 56 s groundwater discharge tracer application, as well as oceanographic time series and thermal infrared imagery analyses. In combination, this suite of techniques provides new insight into the connectivity of the coastal aquifer with the near-shore ocean and examines the physical drivers of submarine groundwater discharge. Lastly, submarine groundwater discharge derived constituent concentrations were tabulated and compared to surrounding seawater concentrations. Such work has implications for the management of coastal aquifers and downstream nearshore ecosystems that respond to sustained constituent loadings via this submarine route.

  17. Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Petr; Člupek, Martin; Babický, Václav; Šunka, Pavel; Janda, V.

    2005-01-01

    Roč. 38, č. 3 (2005), s. 409-416 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GA202/02/1026 Institutional research plan: CEZ:AV0Z20430508 Keywords : Corona discharge * hybrid reactor * ozone * water treatment Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.957, year: 2005

  18. Service use and costs for people with long-term neurological conditions in the first year following discharge from in-patient neuro-rehabilitation: a longitudinal cohort study.

    Directory of Open Access Journals (Sweden)

    Diana Jackson

    Full Text Available BACKGROUND: Knowledge of the configuration and costs of community rehabilitation and support for people with long-term neurological conditions (LTNCs is needed to inform future service development and resource allocation. In a multicentre prospective cohort study evaluating community service delivery during the year post-discharge from in-patient neuro-rehabilitation, a key objective was to determine service use, costs, and predictors of these costs. METHODS: Patients consecutively admitted over one year to all nine London specialised (Level 1 in-patient neuro-rehabilitation units were recruited on discharge. They or their carers completed postal/web-based questionnaires at discharge and six and twelve months later, providing demographic data and measures of impairment, disability, service needs and provision. This paper describes health and social care service use, informal care and associated costs. Regression models using non-parametric boot-strapping identified predictors of costs over time. RESULTS: Overall, 152 patients provided consistent data. Mean formal service costs fell significantly from £13,290 (sd £19,369 during the first six months to £9,335 (sd £19,036 from six-twelve months, (t = 2.35, P<0.05, mainly due to declining health service use. At six months, informal care was received on average for 8.2 hours/day, mean cost £14,615 (sd 23,305, comprising 52% of overall care costs. By twelve months, it had increased to 8.8 hours per day, mean cost £15,468 (sd £25,534, accounting for 62% of overall care costs. Being younger and more disabled predicted higher formal care costs, explaining 32% and 30% of the variation in costs respectively at six and twelve months. CONCLUSION: Community services for people with LTNCs carry substantial costs that shift from health to social care over time, increasing the burden on families. Prioritising rehabilitation services towards those in greatest need could limit access to others needing on

  19. A direct comparison of decision rules for early discharge of suspected acute coronary syndromes in the era of high sensitivity troponin.

    Science.gov (United States)

    Chew, Pei Gee; Frost, Fredrick; Mullen, Liam; Fisher, Michael; Zadeh, Heidar; Grainger, Ruth; Albouaini, Khaled; Dodd, James; Patel, Bilal; Velavan, Periaswamy; Kunadian, Babu; Rawat, Anju; Obafemi, Toba; Tong, Sarah; Jones, Julia; Khand, Aleem

    2018-02-01

    We tested the hypothesis that a single high sensitivity troponin at limits of detection (LOD HSTnT) (Acute Coronary Events (GRACE) (acute coronary syndrome. In a prospective cohort study, risk scores were computed in consecutive patients with suspected acute coronary syndrome presenting to the Emergency Room of a large English hospital. Adjudication of myocardial infarction, as per third universal definition, involved a two-physician, blinded, independent review of all biomarker positive chest pain re-presentations to any national hospital. The primary and secondary outcome was a composite of type 1 myocardial infarction, unplanned coronary revascularisation and all cause death (MACE) at six weeks and one year. Of 3054 consecutive presentations with chest pain 1642 had suspected acute coronary syndrome (52% male, median age 59 years, 14% diabetic, 20% previous myocardial infarction). Median time from chest pain to presentation was 9.7 h. Re-presentations occurred in eight hospitals with 100% follow-up achieved. Two hundred and eleven (12.9%) and 279 (17%) were adjudicated to suffer MACE at six weeks and one year respectively. Only HEART ≤3 (negative predictive value MACE 99.4%, sensitivity 97.6%, %discharge 53.4) and LOD HSTnT strategy (negative predictive value MACE 99.8%, sensitivity 99.5%, %discharge 36.9) achieved pre-specified negative predictive value of >99% for MACE at six weeks. For type 1 myocardial infarction alone the negative predictive values at six weeks and one year were identical, for both HEART ≤3 and LOD HSTnT at 99.8% and 99.5% respectively. HEART ≤3 or LOD HSTnT strategy rules out short and medium term myocardial infarction with ≥99.5% certainty, and short-term MACE with >99% certainty, allowing for early discharge of 53.4% and 36.9% respectively of suspected acute coronary syndrome. Adoption of either strategy has the potential to greatly reduce Emergency Room pressures and minimise follow-up investigations. Very early presenters (<3 h

  20. Electron beam generation in z-pinch discharges

    Energy Technology Data Exchange (ETDEWEB)

    Vikhrev, V.V.; Baronova, E.O. [Kurchatov Inst., Moscow (Russian Federation). Russian Research Center

    1997-12-31

    Numerical modelling of the process of electron beam generation in z-pinch discharges are presented. The proposed model represents the electron beam generation under turbulent plasma conditions. Strong current distribution inhomogeneity in the plasma column and the zigzag drift current motion through the plasma have accounted for the adequate generation process investigation. Electron beam is generated near the maximum of compression and it is not related with the current break effect. (author)

  1. Investigation on maximum transition temperature of phonon mediated superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Fusui, L; Yi, S; Yinlong, S [Physics Department, Beijing University (CN)

    1989-05-01

    Three model effective phonon spectra are proposed to get plots of {ital T}{sub {ital c}}-{omega} adn {lambda}-{omega}. It can be concluded that there is no maximum limit of {ital T}{sub {ital c}} in phonon mediated superconductivity for reasonable values of {lambda}. The importance of high frequency LO phonon is also emphasized. Some discussions on high {ital T}{sub {ital c}} are given.

  2. Evaluation of common organisms causing vaginal discharge.

    Science.gov (United States)

    Khan, Shazia A; Amir, Fauzia; Altaf, Shagufta; Tanveer, Raazia

    2009-01-01

    Vaginal discharge is very common problem among females. Alteration in balance of normal vaginal organisms can cause the overgrowth of the bacteria that creates vaginal discharge. It is common among sexually active women yet there still remain gaps in our knowledge of this infectious disorder. To evaluate the frequency of bacterial vaginosis (BV), vaginal candidiasis (VC), vaginal trichomoniasis and Group B streptococcus in women complaining of vaginal discharge in our setup. A total of 100 women of reproductive age group with the complaint of vaginal discharge were included in the study. After filling proforma patients were examined by speculum examination and two high vaginal swabs (HVS) were collected aseptically from each patient. One swab was used for making wet mount for clue cells, pus cells and for motility of Trichomonas vaginalis. The other swab was used to check pH and Amine test. The growth was confirmed by Gram staining in each case. Gardnerrella vaginalis were isolated in 28%, Group B streptococcus in 5% and T. vaginolis in 4% of women. Gardnerella vaginalis causing BV is the most common cause of vaginal discharge in otherwise healthy women of reproductive age group in our setup.

  3. The Impacts of Climate Change on the Discharge of Osse-Ossiomo ...

    African Journals Online (AJOL)

    There is a strong evidence of global warming using the index of temperature in the drainage basin. River discharge also indicated fluctuating trends from year to year in the decades with available discharge records. It was concluded that the river discharge pattern of Osse-Ossiomo River Basin, S. W. Nigeria exhibited ...

  4. Influence of Duty Cycle on Ozone Generation and Discharge Using Volume Dielectric Barrier Discharge

    Czech Academy of Sciences Publication Activity Database

    Wei, L.S.; Pongrác, Branislav; Zhang, Y.F.; Liang, X.; Prukner, Václav; Šimek, Milan

    2018-01-01

    Roč. 38, č. 2 (2018), s. 355-364 ISSN 0272-4324 R&D Projects: GA ČR(CZ) GA15-04023S Institutional support: RVO:61389021 Keywords : Ozone generation * Volume dielectric barrier discharge * Electrical characteristics * Duty cycle * Adjustable ozone concentration Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.355, year: 2016 https://link.springer.com/article/10.1007%2Fs11090-017-9866-y

  5. A survey of prosthetic eye wearers to investigate mucoid discharge

    Directory of Open Access Journals (Sweden)

    Pine K

    2012-05-01

    Full Text Available Keith Pine1, Brian Sloan2, Joanna Stewart3, Robert J Jacobs11Department of Optometry and Vision Science, 2Department of Ophthalmology, New Zealand National Eye Centre, 3Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New ZealandBackground: This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients.Methods: An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists’ Web sites containing comments on the cause and treatment of discharge were surveyed.Results: Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists’ Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes.Conclusions: A standardized treatment

  6. Electric ignition energy evaluation and the energy distribution structure of energy released in electrostatic discharge process

    International Nuclear Information System (INIS)

    Liu Qingming; Huang Jinxiang; Shao Huige; Zhang Yunming

    2017-01-01

    Ignition energy is one of the important parameters of flammable materials, and evaluating ignition energy precisely is essential to the safety of process industry and combustion science and technology. By using electric spark discharge test system, a series of electric spark discharge experiments were conducted with the capacitor-stored energy in the range of 10 J, 100 J, and 1000 J, respectively. The evaluation method for energy consumed by electric spark, wire, and switch during capacitor discharge process has been studied respectively. The resistance of wire, switch, and plasma between electrodes has been evaluated by different methods and an optimized evaluation method has been obtained. The electric energy consumed by wire, electric switch, and electric spark-induced plasma between electrodes were obtained and the energy structure of capacitor-released energy was analyzed. The dynamic process and the characteristic parameters (the maximum power, duration of discharge process) of electric spark discharge process have been analyzed. Experimental results showed that, electric spark-consumed energy only accounts for 8%–14% of the capacitor-released energy. With the increase of capacitor-released energy, the duration of discharge process becomes longer, and the energy of plasma accounts for more in the capacitor-released energy. The power of electric spark varies with time as a damped sinusoids function and the period and the maximum value increase with the capacitor-released energy. (paper)

  7. Incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients

    OpenAIRE

    Ruengorn, Chidchanok; Sanichwankul, Kittipong; Niwatananun, Wirat; Mahatnirunkul, Suwat; Pumpaisalchai, Wanida; Patumanond, Jayanton

    2011-01-01

    Chidchanok Ruengorn1, Kittipong Sanichwankul2, Wirat Niwatananun3, Suwat Mahatnirunkul2, Wanida Pumpaisalchai2, Jayanton Patumanond11Clinical Epidemiology Unit, Faculty of Medicine, Chiang Mai University; 2Suanprung Psychiatric Hospital; 3Department of Pharmaceutical Care, Faculty of Pharmacy, Chiang Mai University, Chiang Mai, ThailandBackground: The incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients remain uninvestig...

  8. Excitation of RF oscillations in a discharge with negative differential conductivity

    International Nuclear Information System (INIS)

    Antonov, A.N.; Kovpik, O.F.; Kornilov, E.A.

    2001-01-01

    The excitation of oscillations in a discharge with negative differential conductivity is studied experimentally. The possibility is demonstrated of amplifying oscillations in the cathode dark space at frequencies close to the electron plasma frequency of the positive-column plasma. The phase velocities of waves at these frequencies are determined. When the waves pass from the cathode dark space to the discharge positive column, their phase velocities decrease; the closer the frequency is to the electron plasma frequency, the more pronounced the decrease in the phase velocity. As the intensity of oscillations increases, the discharge becomes non-steady-state. This is confirmed by the time evolution of the current-voltage characteristic. The shape of the current-voltage characteristic, its splitting, and the rate at which it varies depend on the input RF power. The decrease in the cathode dark space indicates that the ionization processes in the discharge are strongly influenced by electron plasma oscillations excited due to the collective interaction of the electron beam formed at the cathode with the discharge plasma. It is these processes that determine the maximum values of both the frequency of the excited oscillations and the power that can be withdrawn from the discharge

  9. Discharge behaviors during plasma electrolytic oxidation on aluminum alloy

    International Nuclear Information System (INIS)

    Liu, Run; Wu, Jie; Xue, Wenbin; Qu, Yao; Yang, Chaolin; Wang, Bin; Wu, Xianying

    2014-01-01

    A plasma electrolytic oxidation (PEO) process was performed on the 2024 aluminum alloy in silicate electrolyte to fabricate ceramic coatings under a constant voltage. Optical emission spectroscopy (OES) was employed to evaluate the characteristics of plasma discharge during PEO process. The plasma electron temperature and density were obtained by analyzing the spectral lines of OES, and the atomic ionization degree in discharge zone was calculated in terms of Saha thermal ionization equation. The illumination intensity of plasma discharge and the temperature in the interior of alloy were measured. Combining the surface morphology and cross-sectional microstructure with the optical emission spectra and illumination at different discharge stage, a discharge model in the growth of PEO ceramic coatings was proposed. It is found that there are two discharge modes of type A with small spark size and type B with large spark size, and the latter only appears in the intermediate stage of PEO process. The illumination intensity has a maximum value in the initial stage of oxidation with many sparks of discharge type A. The electron temperature in plasma discharge zone is about 3000 K–7000 K and atomic ionization degree of Al is about 2.0 × 10 −5 –7.2 × 10 −3 , which depend on discharge stage. The discharge type B plays a key role on the electron temperature and atomic ionization degree. The electron density keeps stable in the range of about 8.5 × 10 21  m −3 –2.6 × 10 22  m −3 . - Highlights: • The characteristics of PEO plasma discharge was evaluated by OES. • Electron temperature, concentration, atomic ionization degree were calculated. • Discharge model for the growth of PEO coatings was proposed. • Temperature in the interior of alloy during PEO process was measured

  10. Observations of nearshore groundwater discharge: Kahekili Beach Park submarine springs, Maui, Hawaii

    Science.gov (United States)

    Swarzenski, Peter W.; Dulai, H.; Kroeger, K.D.; Smith, C.G.; Dimova, N.; Storlazzi, C. D.; Prouty, N.G.; Gingerich, S.B.; Glenn, C. R.

    2016-01-01

    Study regionThe study region encompasses the nearshore, coastal waters off west Maui, Hawaii. Here abundant groundwater—that carries with it a strong land-based fingerprint—discharges into the coastal waters and over a coral reef.Study focusCoastal groundwater discharge is a ubiquitous hydrologic feature that has been shown to impact nearshore ecosystems and material budgets. A unique combined geochemical tracer and oceanographic time-series study addressed rates and oceanic forcings of submarine groundwater discharge at a submarine spring site off west Maui, Hawaii.New hydrological insights for the regionEstimates of submarine groundwater discharge were derived for a primary vent site and surrounding coastal waters off west Maui, Hawaii using an excess 222Rn (t1/2 = 3.8 d) mass balance model. Such estimates were complemented with a novel thoron (220Rn,t1/2 = 56 s) groundwater discharge tracer application, as well as oceanographic time series and thermal infrared imagery analyses. In combination, this suite of techniques provides new insight into the connectivity of the coastal aquifer with the near-shore ocean and examines the physical drivers of submarine groundwater discharge. Lastly, submarine groundwater discharge derived constituent concentrations were tabulated and compared to surrounding seawater concentrations. Such work has implications for the management of coastal aquifers and downstream nearshore ecosystems that respond to sustained constituent loadings via this submarine route.

  11. Review of laser-induced fluorescence methods for measuring rf- and microwave electric fields in discharges

    International Nuclear Information System (INIS)

    Gavrilenko, V.; Oks, E.

    1994-01-01

    Development of methods for measuring rf- or μ-wave electric fields E(t) = E 0 cosωt in discharge plasmas is of a great practical importance. First, these are fields used for producing rf- or μ-wave discharges. Second, the fields E(t) may represent electromagnetic waves penetrating into a plasma from the outside. This paper reviews methods for diagnostics of the fields E(t) in low temperature plasmas based on Laser-Induced Fluorescence (LIF). Compared to emission (passive) methods, LIF-methods have a higher sensitivity as well as higher spatial and temporal resolutions. Underlying physical effects may be highlighted by an example of LIF of hydrogen atoms in a plasma. After a presentation of the underlying physical principles, the review focuses on key experiments where these principles were implemented for measurements of rf- and μ-wave electric fields in various discharges

  12. High-k shallow traps observed by charge pumping with varying discharging times

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Szu-Han; Chen, Ching-En; Tseng, Tseung-Yuen [Department of Electronics Engineering, National Chiao Tung University, Hsinchu 300, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Advanced Optoelectronics Technology Center, National Cheng Kung University, Tainan, Taiwan (China); Lu, Ying-Hsin; Lo, Wen-Hung; Tsai, Jyun-Yu; Liu, Kuan-Ju [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Wang, Bin-Wei; Cao, Xi-Xin [Department of Embedded System Engineering, Peking University, Beijing, P.R.China (China); Chen, Hua-Mao [Department of Photonics and Institute of Electro-Optical Engineering, National Chiao Tung University, Hsinchu, Taiwan (China); Cheng, Osbert; Huang, Cheng-Tung; Chen, Tsai-Fu [Device Department, United Microelectronics Corporation, Tainan Science Park, Taiwan (China)

    2013-11-07

    In this paper, we investigate the influence of falling time and base level time on high-k bulk shallow traps measured by charge pumping technique in n-channel metal-oxide-semiconductor field-effect transistors with HfO{sub 2}/metal gate stacks. N{sub T}-V{sub high} {sub level} characteristic curves with different duty ratios indicate that the electron detrapping time dominates the value of N{sub T} for extra contribution of I{sub cp} traps. N{sub T} is the number of traps, and I{sub cp} is charge pumping current. By fitting discharge formula at different temperatures, the results show that extra contribution of I{sub cp} traps at high voltage are in fact high-k bulk shallow traps. This is also verified through a comparison of different interlayer thicknesses and different Ti{sub x}N{sub 1−x} metal gate concentrations. Next, N{sub T}-V{sub high} {sub level} characteristic curves with different falling times (t{sub falling} {sub time}) and base level times (t{sub base} {sub level}) show that extra contribution of I{sub cp} traps decrease with an increase in t{sub falling} {sub time}. By fitting discharge formula for different t{sub falling} {sub time}, the results show that electrons trapped in high-k bulk shallow traps first discharge to the channel and then to source and drain during t{sub falling} {sub time}. This current cannot be measured by the charge pumping technique. Subsequent measurements of N{sub T} by charge pumping technique at t{sub base} {sub level} reveal a remainder of electrons trapped in high-k bulk shallow traps.

  13. Post-discharge kidney function is associated with subsequent ten-year renal progression risk among survivors of acute kidney injury.

    Science.gov (United States)

    Sawhney, Simon; Marks, Angharad; Fluck, Nick; Levin, Adeera; McLernon, David; Prescott, Gordon; Black, Corri

    2017-08-01

    The extent to which renal progression after acute kidney injury (AKI) arises from an initial step drop in kidney function (incomplete recovery), or from a long-term trajectory of subsequent decline, is unclear. This makes it challenging to plan or time post-discharge follow-up. This study of 14651 hospital survivors in 2003 (1966 with AKI, 12685 no AKI) separates incomplete recovery from subsequent renal decline by using the post-discharge estimated glomerular filtration rate (eGFR) rather than the pre-admission as a new reference point for determining subsequent renal outcomes. Outcomes were sustained 30% renal decline and de novo CKD stage 4, followed from 2003-2013. Death was a competing risk. Overall, death was more common than subsequent renal decline (37.5% vs 11.3%) and CKD stage 4 (4.5%). Overall, 25.7% of AKI patients had non-recovery. Subsequent renal decline was greater after AKI (vs no AKI) (14.8% vs 10.8%). Renal decline after AKI (vs no AKI) was greatest among those with higher post-discharge eGFRs with multivariable hazard ratios of 2.29 (1.88-2.78); 1.50 (1.13-2.00); 0.94 (0.68-1.32) and 0.95 (0.64-1.41) at eGFRs of 60 or more; 45-59; 30-44 and under 30, respectively. The excess risk after AKI persisted over ten years of study, irrespective of AKI severity, or post-episode proteinuria. Thus, even if post-discharge kidney function returns to normal, hospital admission with AKI is associated with increased renal progression that persists for up to ten years. Follow-up plans should avoid false reassurance when eGFR after AKI returns to normal. Copyright © 2017 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  14. Temporally resolved imaging on quenching and re-ignition of nanosecond underwater discharge

    Directory of Open Access Journals (Sweden)

    Yong Yang

    2012-12-01

    Full Text Available This paper presents the temporally resolved images of plasma discharge in de-ionized water. The discharge was produced by high voltage pulses with 0.3 ns rise time and 10 ns duration. The temporal resolution of the imaging system was one nanosecond. A unique three-stage process, including a fast ignition at the leading edge of the pulse, quenching at the plateau of the pulse, and self re-ignition at the trailing edge of the pulse, was observed in a single pulse cycle. The maximum measured propagation velocity of the plasma discharge was about 1000 km/s. The possibility of direct ionization in water under high reduced electric field conditions was discussed.

  15. Age and weight at final discharge from an early discharge programme for stable but tube-fed preterm infants

    DEFF Research Database (Denmark)

    Ahnfeldt, A M; Stanchev, H.; Jørgensen, Henrik Løvendahl

    2015-01-01

    the programme (p difference in weight-for-age at discharge (p = 0.15), but infants in the early discharge group were more frequently fully or partly breastfed (88% versus 80%, p ... comparability of the two groups, weight-for-age at discharge was similar, but the programme appeared to allow better breastfeeding success at the expense of a later final discharge......., and during the programme, they received home visits by neonatal nurses. We evaluated the programme, focusing on the infants' well-being, using weight gain, breastfeeding rates and total duration of hospitalisation as outcomes. METHODS: Over an 11-year period, 500 infants participated in the programme...

  16. Enhanced performance on high current discharges in JET produced by ICRF heating during the current rise

    International Nuclear Information System (INIS)

    Bures, M.; Bhatnagar, V.; Cotrell, G.; Corti, S.; Christiansen, J.P.; Hellsten, T.; Jacquinot, J.; Lallia, P.; Lomas, P.; O'Rourke, J.; Taroni, A.; Tibone, F.; Start, D.F.H.

    1989-01-01

    The performance of high current discharges can be increased by applying central ICRF heating before or shortly after the onset of sawtooth activity in the plasma current rise phase. Sawtooth-free periods have been obtained resulting in the enhanced discharge performance. High T e (0) 9 - 10.5 keV with peaked profiles T e (0)/ e > = 3 - 4 were obtained giving values of n e (0)T e (0) up to 6x10 20 (keV m -3 ). Improvements in T i (0) and neutron production are observed. A 60 % enhancement in D-D reaction rate from 2nd harmonic deuterium (2ω CD ) heating appears to be present. In all current rise (CR) discharges radiation amounts to 25-50 % of total power. (author) 4 refs., 6 figs

  17. High brightness extreme ultraviolet (at 13.5 nm) emission from time-of-flight controlled discharges with coaxial fuel injection

    International Nuclear Information System (INIS)

    Hosokai, Tomonao; Horioka, Kazuhiko; Hotta, Eiki; Yokoyama, Takuma; Sato, Hiroto; Zhidkov, Alexei

    2008-01-01

    Extreme ultraviolet (EUV) emission from discharge produced plasma with the coaxial injection of fuel vapor (tin and lithium) produced by laser ablation is experimentally studied. Multiple plasma pinches preceding a strong and long recombination radiation of EUV are observed in the first half cycle of a sinusoidal discharge current. Due to the time-of-flight control type of the discharge, the shape of pinch radiation pulses is almost identical. With the coaxial injection of time-of-flight controlled discharges, the highest brightness of EUV emission (maximum extracted energy of 244.3 mJ/2π sr per pulse with the emitter size of ∼1x0.3 mm 2 in full width at half maximum) is provided with efficiency exceeding 2% of deposited energy into the plasma (or 1% of dissipated energy in the discharge) due to a much better matching with the optimal plasma parameters in the recombination regime and a decrease in the off-duty factor. Stability of emitting plasma of the repetitive pinches is essentially improved with use of a second laser pulse

  18. Spectroscopic study of ohmically heated Tokamak discharges

    International Nuclear Information System (INIS)

    Breton, C.; Michelis, C. de; Mattioli, M.

    1980-07-01

    Tokamak discharges interact strongly with the wall and/or the current aperture limiter producing recycling particles, which penetrate into the discharge and which can be studied spectroscopically. Working gas (hydrogen or deuterium) is usually studied observing visible Balmer lines at several toroidal locations. Absolute measurements allow to obtain both the recycling flux and the global particle confinement time. With sufficiently high resolution the isotopic plasma composition can be obtained. The impurity elements can be divided into desorbed elements (mainly oxygen) and eroded elements (metals from both walls and limiter) according to the plasma-wall interaction processes originating them. Space-and time-resolved emission in the VUV region down to about 20 A will be reviewed for ohmically-heated discharges. The time evolution can be divided into four phases, not always clearly separated in a particular discharge: a) the initial phase, lasting less than 10 ms (the so-called burn-out phase), b) the period of increasing plasma current and electron temperature, lasting typically 10 - 100 ms, c) an eventual steady state (plateau of the plasma current with almost constant density and temperature), d) the increase of the electron density up to or just below the maximum value attainable in a given device. For all these phases the results reported from different devices will be described and compared

  19. Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee. Establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T

    International Nuclear Information System (INIS)

    Moriya, Susumu; Miki, Yukio; Matsuno, Yukako; Okada, Masayo

    2012-01-01

    Background: The effect of flip angle (FA) on synovial fluid and cartilage signal and on image contrast using three-dimensional double-echo steady-state (3D-DESS) sequence have only been performed with 1.0-T but not with 1.5-T or 3.0-T scanners. Purpose: To identify the FA that gives the maximum synovial fluid and cartilage values, and to identify the FA at which maximum values of synovial fluid-cartilage contrast-to-noise ratio (CNR) in 3D-DESS sequences when 1.5-T and 3.0-T scanners are used. Material and Methods: Using 3D-DESS with water-excitation pulse, mid-sagittal plane images of the knees of 10 healthy volunteers (5 men, 5 women; age range, 21-42 years) were obtained with FA varying from 10 deg to 90 deg. Synovial fluid signals, cartilage signals, and background were measured at each FA, and the FA that gave the highest synovial fluid and cartilage values was obtained. Synovial fluid-cartilage CNR was also calculated, and the FA that gave the largest CNR was obtained. Results: At 1.5 T, the maximum synovial fluid signal was at FA 90 deg, and the maximum cartilage signal was at FA 30 deg. Synovial fluid-cartilage CNR was highest at FA 90 deg (P < 0.05). At 3.0 T, the maximum synovial fluid signal was at FA 90 deg, and the maximum cartilage signal was at FA 20 deg. Synovial fluid-cartilage CNR was highest at FA 90 deg (P < 0.05). Conclusion: In order to improve the visibility of cartilage itself, FA settings of 30 deg at 1.5 T and 20 deg at 3.0 T are apparently ideal. For observing the cartilage surface, the most effective FA setting is 90 deg for both 1.5 T and 3.0 T

  20. Central peaking of magnetized gas discharges

    International Nuclear Information System (INIS)

    Chen, Francis F.; Curreli, Davide

    2013-01-01

    Partially ionized gas discharges used in industry are often driven by radiofrequency (rf) power applied at the periphery of a cylinder. It is found that the plasma density n is usually flat or peaked on axis even if the skin depth of the rf field is thin compared with the chamber radius a. Previous attempts at explaining this did not account for the finite length of the discharge and the boundary conditions at the endplates. A simple 1D model is used to focus on the basic mechanism: the short-circuit effect. It is found that a strong electric field (E-field) scaled to electron temperature T e , drives the ions inward. The resulting density profile is peaked on axis and has a shape independent of pressure or discharge radius. This “universal” profile is not affected by a dc magnetic field (B-field) as long as the ion Larmor radius is larger than a

  1. Employing Ti nano-powder dielectric to enhance surface characteristics in electrical discharge machining of AISI D2 steel

    Energy Technology Data Exchange (ETDEWEB)

    Marashi, Houriyeh, E-mail: houriyeh@marashi.co [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia); Sarhan, Ahmed A.D., E-mail: ah_sarhan@yahoo.com [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia); Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Assiut 71516 (Egypt); Hamdi, Mohd [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia)

    2015-12-01

    Graphical abstract: - Highlights: • We proposed adding Ti nano-powder to dielectric in EDM. • Average and peak-valley surface roughness was improved by 35 and 40%, respectively. • Improvement of up to 69% in material removal rate was obtained. • Enhanced surface morphology and formation of shallower craters were observed. - Abstract: Manufacturing components with superior surface characteristics is challenging when electrical discharge machining (EDM) is employed for mass production. The aim of this research is to enhance the characteristics of AISI D2 steel surface machined with EDM through adding Ti nano-powder to dielectric under various machining parameters, including discharge duration (T{sub on}) and peak current (I). Surface roughness profilometer, FESEM and AFM analysis were utilized to reveal the machined surface characteristics in terms of surface roughness, surface morphology and surface micro-defects. Moreover, EDX analysis was performed in order to evaluate the atomic deposition of Ti nano-powder on the surface. The concentration of Ti nano-powder in dielectric was also examined using ESEM and EDX. According to the results, the addition of Ti nano-powder to dielectric notably enhanced the surface morphology and surface roughness at all machining parameters except T{sub on} = 340 μs. Of these parameters, maximum enhancement was observed at T{sub on} = 210 μs, where the material removal rate and average surface roughness improved by ∼69 and ∼35% for peak current of 6 and 12 A, respectively. Elemental analysis signified negligible Ti deposition on the machined surface while the atomic concentration of Ti was increased around the crack areas.

  2. Vaginal Fornix Discharge Cellularity and Its Leukocyte Esterase Activity for Diagnosis of Endometritis in Dairy Cows

    Directory of Open Access Journals (Sweden)

    Abolfazl HAJIBEMANI

    2016-01-01

    Full Text Available The objective of the present study was to evaluate the application of some strip test markers (i.e., leukocyte esterase (LE activity, protein, nitrate and pH for diagnosis of endometritis in dairy cows using vaginal fornix discharge. Also, the total white blood cell count (t-WBC/l of this secretion and degenerative changes of neutrophils in cervical cytology were used as alternative methods to predict progression of the endometritis severity. Holstein cows (n=215 between 30-40 days in milk (DIM were included and examined. Giemsa-stained smear was prepared from cervical mucus. Cervical cytology test was considered as reference screening method for the detection of subclinical endometritis. The LE activity and t-WBC in the vaginal fornix discharge of subclinical endometritis cows were significantly higher than those from healthy cows. Sensitivity and specificity were 78% and 73% for LE10 activity (10 minutes after contacting with discharges and 60% and 69% for t-WBC (cut off point=210 cells/l for diagnosis of subclinical endometritis, respectively. There was a good agreement between LE10 activity, t-WBC and cervical cytology test with a Kappa coefficient of 0.4 and 0.42, respectively (P<0.0001. Total WBC count in discharge and degenerative neutrophils (DN percentages increase simultaneously with the degree and severity of endometritis. There was a highly significant (P<0.01 correlation between t-WBC and some reagent strip test markers (LE activity, protein and nitrate in clear discharge of studied cows. In conclusion, the present results suggest the LE activity and t-WBC in vaginal fornix discharge could be used as non-invasive reliable and valid methods for screening of subclinical endometritis in postpartum dairy herds.

  3. Global-scale high-resolution ( 1 km) modelling of mean, maximum and minimum annual streamflow

    Science.gov (United States)

    Barbarossa, Valerio; Huijbregts, Mark; Hendriks, Jan; Beusen, Arthur; Clavreul, Julie; King, Henry; Schipper, Aafke

    2017-04-01

    Quantifying mean, maximum and minimum annual flow (AF) of rivers at ungauged sites is essential for a number of applications, including assessments of global water supply, ecosystem integrity and water footprints. AF metrics can be quantified with spatially explicit process-based models, which might be overly time-consuming and data-intensive for this purpose, or with empirical regression models that predict AF metrics based on climate and catchment characteristics. Yet, so far, regression models have mostly been developed at a regional scale and the extent to which they can be extrapolated to other regions is not known. We developed global-scale regression models that quantify mean, maximum and minimum AF as function of catchment area and catchment-averaged slope, elevation, and mean, maximum and minimum annual precipitation and air temperature. We then used these models to obtain global 30 arc-seconds (˜ 1 km) maps of mean, maximum and minimum AF for each year from 1960 through 2015, based on a newly developed hydrologically conditioned digital elevation model. We calibrated our regression models based on observations of discharge and catchment characteristics from about 4,000 catchments worldwide, ranging from 100 to 106 km2 in size, and validated them against independent measurements as well as the output of a number of process-based global hydrological models (GHMs). The variance explained by our regression models ranged up to 90% and the performance of the models compared well with the performance of existing GHMs. Yet, our AF maps provide a level of spatial detail that cannot yet be achieved by current GHMs.

  4. 2001 – 2010 Dansk Design Reference Year Supplerende datasæt

    DEFF Research Database (Denmark)

    Grunnet Wang, Peter; Scharling, Mikael; Wittchen, Kim Bjarne

    Det danske Design Reference Year (DRY) datasæt blev præsenteret i 2012 [1], specielt med henblik på teknisk dimensionering indenfor solenergi-sektoren. I nærværende rapport præsenteres et supplerende datasæt for parametrene atmosfæretryk, vindretning, skydække, vandtemperatur samt jordtemperatur....... tillæg til det supplerende datasæt er der præsenteret et separat datasæt til byggesagsbehandling, se afsnit 6. Dette datasæt indeholder data fra blot én station pr. parameter, der er blevet udvalgt som værende repræsentativ for hele Danmark....

  5. 17 CFR 240.17Ad-21T - Operational capability in a Year 2000 environment.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Operational capability in a Year 2000 environment. 240.17Ad-21T Section 240.17Ad-21T Commodity and Securities Exchanges SECURITIES... Company Rules § 240.17Ad-21T Operational capability in a Year 2000 environment. (a) This section applies...

  6. Changes in the T2 value of cartilage after meniscus transplantation over 1 year.

    Science.gov (United States)

    Park, Sun-Young; Lee, Sang Hoon; Lee, Min Hee; Chung, Hye Won; Shin, Myung Jin

    2017-04-01

    To evaluate the changes in the mean T2 values of articular cartilage on serial follow-up images up to 1 year in patients who underwent lateral meniscus allograft transplantation (MAT). Fifty-two patients who underwent lateral MAT surgery at our hospital were evaluated preoperatively and at 2 days, 6 weeks, 3 months, 6 months, and 1 year after MAT using 3.0-T magnetic resonance imaging (MRI) that included T2 mapping. T2 value changes according to the arthroscopic grading of chondromalacia were evaluated in the lateral and medial compartment. Lysholm scores were obtained pre- and postoperatively. The T2 values of cartilage were significantly increased 2 days after operation, and then gradually reduced to the baseline level after 1 year in both compartments. In morphologic assessment performed after 1 year, most areas (92.9 %) showed no interval change of chondromalacia grade. Lyshom knee scores increased significantly from the mean preoperative value of 62.5 (range, 23-95) to 89.7 (range, 64-100) at 1 year (p < 0.001). Mean T2 values of cartilage following MAT exhibited a return to baseline level after 1 year. T2 measurement can be a useful tool for quantitative evaluation of postoperative cartilage changes compared to conventional MRI. • T2 mapping provides objective data for longitudinal monitoring following surgery. • Increased cartilage T2 values post-MAT returned to baseline in one year. • Further studies are required to predict the chondroprotective effect of MAT.

  7. Proposed experiment to investigate use of heated optical fibers for tokamak diagnostics during D-T discharges

    International Nuclear Information System (INIS)

    Tighe, W.; Morgan, P.; Griscom, D.; Adler, H.; Cylinder, D.; Johnson, D.; Palladino, D.; Ramsey, A.

    1995-02-01

    A collaborative JET/TFTR study has been undertaken to investigate attenuation and luminescence effects due to neutron irradiation of optical fibers heated to 400 degrees C. It is expected that a significant improvement in fiber behavior will be observed due to thermal annealing. This technique may be important for use in fiber-related, tokamak diagnostics exposed to high neutron flux. The study will make use of aluminum jacketed, 600 μm diameter, all silica (F-doped cladding) fibers in lengths of 150 m. The fibers are prepared in 1 foot coils. Of the coils to be irradiated, one is heated constantly to 400 degrees C, a second is not heated, and a third is heated periodically. A fourth fiber coil is not to be irradiated. Spectrally and temporally resolved transmission and luminescence data under neutron irradiation during D-T discharges on TFTR will be obtained. An investigation of permanent and short term effects will be made. Experimental details along with initial results will be presented

  8. Pharmaceutical manufacturing facility discharges can substantially increase the pharmaceutical load to U.S. wastewaters

    Science.gov (United States)

    Scott, Tia-Marie; Phillips, Patrick J.; Kolpin, Dana W.; Colella, Kaitlyn M.; Furlong, Edward T.; Foreman, William T.; Gray, James L.

    2018-01-01

    Discharges from pharmaceutical manufacturing facilities (PMFs) previously have been identified as important sources of pharmaceuticals to the environment. Yet few studies are available to establish the influence of PMFs on the pharmaceutical source contribution to wastewater treatment plants (WWTPs) and waterways at the national scale. Consequently, a national network of 13 WWTPs receiving PMF discharges, six WWTPs with no PMF input, and one WWTP that transitioned through a PMF closure were selected from across the United States to assess the influence of PMF inputs on pharmaceutical loading to WWTPs. Effluent samples were analyzed for 120 pharmaceuticals and pharmaceutical degradates. Of these, 33 pharmaceuticals had concentrations substantially higher in PMF-influenced effluent (maximum 555,000 ng/L) compared to effluent from control sites (maximum 175 ng/L). Concentrations in WWTP receiving PMF input are variable, as discharges from PMFs are episodic, indicating that production activities can vary substantially over relatively short (several months) periods and have the potential to rapidly transition to other pharmaceutical products. Results show that PMFs are an important, national-scale source of pharmaceuticals to the environment.

  9. Pancreatitis - discharge

    Science.gov (United States)

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  10. On the regime transitions during the formation of an atmospheric pressure dielectric barrier glow discharge

    International Nuclear Information System (INIS)

    Martens, T; Bogaerts, A; Brok, W J M; Van Dijk, J

    2009-01-01

    The atmospheric pressure dielectric barrier discharge in helium is a pulsed discharge in nature. If during the electrical current pulse a glow discharge is reached, then this pulse will last only a few microseconds in operating periods of sinusoidal voltage with lengths of about 10 to 100 μs. In this paper we demonstrate that right before a glow discharge is reached, the discharge very closely resembles the commonly assumed Townsend discharge structure, but actually contains some significant differing features and hence should not be considered as a Townsend discharge. In order to clarify this, we present calculation results of high time and space resolution of the pulse formation. The results indicate that indeed a maximum of ionization is formed at the anode, but that the level of ionization remains high and that the electric field at that time is significantly disturbed. Our results also show where this intermediate structure comes from. (fast track communication)

  11. Modeling the probability distribution of peak discharge for infiltrating hillslopes

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2017-07-01

    Hillslope response plays a fundamental role in the prediction of peak discharge at the basin outlet. The peak discharge for the critical duration of rainfall and its probability distribution are needed for designing urban infrastructure facilities. This study derives the probability distribution, denoted as GABS model, by coupling three models: (1) the Green-Ampt model for computing infiltration, (2) the kinematic wave model for computing discharge hydrograph from the hillslope, and (3) the intensity-duration-frequency (IDF) model for computing design rainfall intensity. The Hortonian mechanism for runoff generation is employed for computing the surface runoff hydrograph. Since the antecedent soil moisture condition (ASMC) significantly affects the rate of infiltration, its effect on the probability distribution of peak discharge is investigated. Application to a watershed in Sicily, Italy, shows that with the increase of probability, the expected effect of ASMC to increase the maximum discharge diminishes. Only for low values of probability, the critical duration of rainfall is influenced by ASMC, whereas its effect on the peak discharge seems to be less for any probability. For a set of parameters, the derived probability distribution of peak discharge seems to be fitted by the gamma distribution well. Finally, an application to a small watershed, with the aim to test the possibility to arrange in advance the rational runoff coefficient tables to be used for the rational method, and a comparison between peak discharges obtained by the GABS model with those measured in an experimental flume for a loamy-sand soil were carried out.

  12. Statistical assessment of changes in extreme maximum temperatures over Saudi Arabia, 1985-2014

    Science.gov (United States)

    Raggad, Bechir

    2018-05-01

    In this study, two statistical approaches were adopted in the analysis of observed maximum temperature data collected from fifteen stations over Saudi Arabia during the period 1985-2014. In the first step, the behavior of extreme temperatures was analyzed and their changes were quantified with respect to the Expert Team on Climate Change Detection Monitoring indices. The results showed a general warming trend over most stations, in maximum temperature-related indices, during the period of analysis. In the second step, stationary and non-stationary extreme-value analyses were conducted for the temperature data. The results revealed that the non-stationary model with increasing linear trend in its location parameter outperforms the other models for two-thirds of the stations. Additionally, the 10-, 50-, and 100-year return levels were found to change with time considerably and that the maximum temperature could start to reappear in the different T-year return period for most stations. This analysis shows the importance of taking account the change over time in the estimation of return levels and therefore justifies the use of the non-stationary generalized extreme value distribution model to describe most of the data. Furthermore, these last findings are in line with the result of significant warming trends found in climate indices analyses.

  13. On the Pontryagin maximum principle for systems with delays. Economic applications

    Science.gov (United States)

    Kim, A. V.; Kormyshev, V. M.; Kwon, O. B.; Mukhametshin, E. R.

    2017-11-01

    The Pontryagin maximum principle [6] is the key stone of finite-dimensional optimal control theory [1, 2, 5]. So beginning with opening the maximum principle it was important to extend the maximum principle on various classes of dynamical systems. In t he paper we consider some aspects of application of i-smooth analysis [3, 4] in the theory of the Pontryagin maximum principle [6] for systems with delays, obtained results can be applied by elaborating optimal program controls in economic models with delays.

  14. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    International Nuclear Information System (INIS)

    Aleksandrov, A. F.; Petrov, A. K.; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B.; Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya.

    2016-01-01

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  15. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, A. F.; Petrov, A. K., E-mail: alpetrov57@gmail.com; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B. [Moscow State University, Faculty of Physics (Russian Federation); Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya. [Research Institute of Precision Engineering (Russian Federation)

    2016-03-15

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  16. Red herring vaginal discharge.

    Science.gov (United States)

    Lee, Jun Hee; Pringle, Kirsty; Rajimwale, Ashok

    2013-09-18

    Labial hair tourniquet syndrome is a rare condition that can be easily misdiagnosed and ultimately lead to irreversible damage. An 11-year-old premenarche girl presented with a 5-day history of pain and swelling in the labia with associated vaginal discharge. The general practitioner treated her with clotrimazole without improvement. On examination, there was an oedematous swelling of the right labia with a proximal hair tourniquet. Local anaesthetic was applied and the hair removed with forceps. There was instant relief of pain and the discharge stopped within 24 h. The patient was sent home with a course of antibiotics.

  17. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  18. Characteristics of ultraviolet light and radicals formed by pulsed discharge in water

    Science.gov (United States)

    Sun, Bing; Kunitomo, Shinta; Igarashi, Chiaki

    2006-09-01

    In this investigation, the ultraviolet light characteristics and OH radical properties produced by a pulsed discharge in water were studied. For the plate-rod reactor, it was found that the ultraviolet light energy has a 3.2% total energy injected into the reactor. The ultraviolet light changed with the peak voltage and electrode distance. UV characteristics in tap water and the distilled water are given. The intensity of the OH radicals was the highest for the 40 mm electrode distance reactor. In addition, the properties of hydrogen peroxide and ozone were also studied under arc discharge conditions. It was found that the OH radicals were in the ground state and the excited state when a pulsed arc discharge was used. The ozone was produced by the arc discharge even if the oxygen gas is not bubbled into the reactor. The ozone concentration produces a maximum value with treatment time.

  19. Characteristics of ultraviolet light and radicals formed by pulsed discharge in water

    Energy Technology Data Exchange (ETDEWEB)

    Sun Bing [Dalian Maritime University, College of Environment, 1st Linghai Road, Dalian (China); Kunitomo, Shinta [Ebara Corporation, 1-6-27, Konan, Minato-ku 108-8480 (Japan); Igarashi, Chiaki [Ebara Research Co. Ltd, 2-1, Honfujisawa 4-chome, Fujisawa 251-8502 (Japan)

    2006-09-07

    In this investigation, the ultraviolet light characteristics and OH radical properties produced by a pulsed discharge in water were studied. For the plate-rod reactor, it was found that the ultraviolet light energy has a 3.2% total energy injected into the reactor. The ultraviolet light changed with the peak voltage and electrode distance. UV characteristics in tap water and the distilled water are given. The intensity of the OH radicals was the highest for the 40 mm electrode distance reactor. In addition, the properties of hydrogen peroxide and ozone were also studied under arc discharge conditions. It was found that the OH radicals were in the ground state and the excited state when a pulsed arc discharge was used. The ozone was produced by the arc discharge even if the oxygen gas is not bubbled into the reactor. The ozone concentration produces a maximum value with treatment time.

  20. Role of turbulence fluctuations on uncertainties of acoutic Doppler current profiler discharge measurements

    Science.gov (United States)

    Tarrab, Leticia; Garcia, Carlos M.; Cantero, Mariano I.; Oberg, Kevin

    2012-01-01

    This work presents a systematic analysis quantifying the role of the presence of turbulence fluctuations on uncertainties (random errors) of acoustic Doppler current profiler (ADCP) discharge measurements from moving platforms. Data sets of three-dimensional flow velocities with high temporal and spatial resolution were generated from direct numerical simulation (DNS) of turbulent open channel flow. Dimensionless functions relating parameters quantifying the uncertainty in discharge measurements due to flow turbulence (relative variance and relative maximum random error) to sampling configuration were developed from the DNS simulations and then validated with field-scale discharge measurements. The validated functions were used to evaluate the role of the presence of flow turbulence fluctuations on uncertainties in ADCP discharge measurements. The results of this work indicate that random errors due to the flow turbulence are significant when: (a) a low number of transects is used for a discharge measurement, and (b) measurements are made in shallow rivers using high boat velocity (short time for the boat to cross a flow turbulence structure).

  1. Novel high-frequency energy-efficient pulsed-dc generator for capacitively coupled plasma discharge

    Science.gov (United States)

    Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu

    2018-03-01

    The circuit design, assembly, and operating tests of a high-frequency and high-voltage (HV) pulsed dc generator (PDG) for capacitively coupled plasma (CCP) discharge inside a vacuum chamber are reported. For capacitive loads, it is challenging to obtain sharp rectangular pulses with fast rising and falling edges, requiring intense current for quick charging and discharging. The requirement of intense current generally limits the pulse operation frequency. In this study, we present a new type of PDG consisting of a pair of half-resonant converters and a constant current-controller circuit connected with HV solid-state power switches that can deliver almost rectangular high voltage pulses with fast rising and falling edges for CCP discharge. A prototype of the PDG is assembled to modulate from a high-voltage direct current (HVdc) input into a pulsed HVdc output, while following an input pulse signal and a set current level. The pulse rise time and fall time are less than 500 ns and 800 ns, respectively, and the minimum pulse width is 1 µs. The maximum voltage for a negative pulse is 1000 V, and the maximum repetition frequency is 500 kHz. During the pulse on time, the plasma discharge current is controlled steadily at the set value. The half-resonant converters in the PDG perform recovery of the remaining energy from the capacitive load at every termination of pulse discharge. The PDG performed with a high energy efficiency of 85% from the HVdc input to the pulsed dc output at a repetition rate of 1 kHz and with stable plasma operation in various discharge conditions. The results suggest that the developed PDG can be considered to be more efficient for plasma processing by CCP.

  2. Novel high-frequency energy-efficient pulsed-dc generator for capacitively coupled plasma discharge.

    Science.gov (United States)

    Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu

    2018-03-01

    The circuit design, assembly, and operating tests of a high-frequency and high-voltage (HV) pulsed dc generator (PDG) for capacitively coupled plasma (CCP) discharge inside a vacuum chamber are reported. For capacitive loads, it is challenging to obtain sharp rectangular pulses with fast rising and falling edges, requiring intense current for quick charging and discharging. The requirement of intense current generally limits the pulse operation frequency. In this study, we present a new type of PDG consisting of a pair of half-resonant converters and a constant current-controller circuit connected with HV solid-state power switches that can deliver almost rectangular high voltage pulses with fast rising and falling edges for CCP discharge. A prototype of the PDG is assembled to modulate from a high-voltage direct current (HVdc) input into a pulsed HVdc output, while following an input pulse signal and a set current level. The pulse rise time and fall time are less than 500 ns and 800 ns, respectively, and the minimum pulse width is 1 µs. The maximum voltage for a negative pulse is 1000 V, and the maximum repetition frequency is 500 kHz. During the pulse on time, the plasma discharge current is controlled steadily at the set value. The half-resonant converters in the PDG perform recovery of the remaining energy from the capacitive load at every termination of pulse discharge. The PDG performed with a high energy efficiency of 85% from the HVdc input to the pulsed dc output at a repetition rate of 1 kHz and with stable plasma operation in various discharge conditions. The results suggest that the developed PDG can be considered to be more efficient for plasma processing by CCP.

  3. Discharge estimation combining flow routing and occasional measurements of velocity

    Directory of Open Access Journals (Sweden)

    G. Corato

    2011-09-01

    Full Text Available A new procedure is proposed for estimating river discharge hydrographs during flood events, using only water level data at a single gauged site, as well as 1-D shallow water modelling and occasional maximum surface flow velocity measurements. One-dimensional diffusive hydraulic model is used for routing the recorded stage hydrograph in the channel reach considering zero-diffusion downstream boundary condition. Based on synthetic tests concerning a broad prismatic channel, the "suitable" reach length is chosen in order to minimize the effect of the approximated downstream boundary condition on the estimation of the upstream discharge hydrograph. The Manning's roughness coefficient is calibrated by using occasional instantaneous surface velocity measurements during the rising limb of flood that are used to estimate instantaneous discharges by adopting, in the flow area, a two-dimensional velocity distribution model. Several historical events recorded in three gauged sites along the upper Tiber River, wherein reliable rating curves are available, have been used for the validation. The outcomes of the analysis can be summarized as follows: (1 the criterion adopted for selecting the "suitable" channel length based on synthetic test studies has proved to be reliable for field applications to three gauged sites. Indeed, for each event a downstream reach length not more than 500 m is found to be sufficient, for a good performances of the hydraulic model, thereby enabling the drastic reduction of river cross-sections data; (2 the procedure for Manning's roughness coefficient calibration allowed for high performance in discharge estimation just considering the observed water levels and occasional measurements of maximum surface flow velocity during the rising limb of flood. Indeed, errors in the peak discharge magnitude, for the optimal calibration, were found not exceeding 5% for all events observed in the three investigated gauged sections, while the

  4. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  5. Discharge Coefficient of Rectangular Short-Crested Weir with Varying Slope Coefficients

    Directory of Open Access Journals (Sweden)

    Yuejun Chen

    2018-02-01

    Full Text Available Rectangular short-crested weirs are widely used for simple structure and high discharge capacity. As one of the most important and influential factors of discharge capacity, side slope can improve the hydraulic characteristics of weirs at special conditions. In order to systemically study the effects of upstream and downstream slope coefficients S1 and S2 on overflow discharge coefficient in a rectangular short-crested weir the Volume of Fluid (VOF method and the Renormalization Group (RNG κ-ε turbulence model are used. In this study, the slope coefficient ranges from V to 3H:1V and each model corresponds to five total energy heads of H0 ranging from 8.0 to 24.0 cm. Comparisons of discharge coefficients and free surface profiles between simulated and laboratory results display a good agreement. The simulated results show that the difference of discharge coefficients will decrease with upstream slopes and increase with downstream slopes as H0 increases. For a given H0, the discharge coefficient has a convex parabolic relation with S1 and a piecewise linearity relation with S2. The maximum discharge coefficient is always obtained at S2 = 0.8. There exists a difference between upstream and downstream slope coefficients in the influence range of free surface curvatures. Furthermore, a proposed discharge coefficient equation by nonlinear regression is a function of upstream and downstream slope coefficients.

  6. Short-term variability of Johor River discharge based on wavelet analysis

    Science.gov (United States)

    Ahmad, N.; Kamaruddin, S. A.; Heryansyah, A.

    2015-02-01

    River discharge provides a direct measure of water quantity and availability of water for specific uses. It also provides the basis for understanding river basin processes and is essential for interpreting and understanding river flow characteristics. This study investigates the temporal variability of river discharge records of Johor River. Wavelet analysis of discharge records for 30 years was carried out to characterize the river flow variability. Our results indicate that Johor River discharge data shows a significant short-term variability of between 0.6 to 2.5 years.

  7. Association of Shoulder Problems in Persons With Spinal Cord Injury at Discharge From Inpatient Rehabilitation With Activities and Participation 5 Years Later

    NARCIS (Netherlands)

    Eriks-Hoogland, I.E.; de Groot, Sonja; Snoek, G.J.; Stucki, G.; Post, MWM; van der Woude, L.H.

    Objective To examine whether musculoskeletal shoulder pain and limitations in shoulder range of motion (ROM) at discharge from first rehabilitation are associated with activities and participation restrictions 5 years later in persons with spinal cord injury (SCI). Design Prospective cohort study.

  8. Association of Shoulder Problems in Persons With Spinal Cord Injury at Discharge From Inpatient Rehabilitation With Activities and Participation 5 Years Later

    NARCIS (Netherlands)

    Eriks-Hoogland, Inge; de Groot, Sonja; Snoek, Govert; Stucki, Gerold; Post, Marcel.; Van der Woude, Lucas

    Objective: To examine whether musculoskeletal shoulder pain and limitations in shoulder range of motion (ROM) at discharge from first rehabilitation are associated with activities and participation restrictions 5 years later in persons with spinal cord injury (SCI). Design: Prospective cohort study.

  9. Distribution of the active liquid waste discharge concentration

    International Nuclear Information System (INIS)

    Chan, A.H.C.

    1985-03-01

    In assessing the proposal for removing the on-line liquid effluent monitor (LEM) from the Darlington NGS-A design, it was required to estimate the probability that the concentration of β-y emitters in the active liquid waste (ALW) tank discharges exceeds a specified level. To achieve this, it was necessary to know the underlying distribution of the ALW discharge concentration. Since the distribution could only be estimated from the historical data, it was also important to provide the confidence interval for the estimated probability. Using the ALW discharge records of Pickering and Bruce NGS-A, it was found that the log-normal distribution provided the best fit for the data. The frequency of the tank concentration exceeding the specified level of 24000μCi/m 3 was estimated to be 1 in 200,000 years at Bruce NGS-A and 1 in 100,000 years at Pickering. The 99% upper confidence limits are 1 in 2777 years and 1 in 77 years, respectively

  10. A descriptive study of urethral discharge among men in Fiji.

    Science.gov (United States)

    Gaunavinaka, Lavenia; Balak, Dashika; Varman, Sumanthla; Ram, Sharan; Graham, Stephen M

    2014-10-17

    Urethral discharge is a common presentation of sexually transmitted infection (STI) in men and known pathogens include Neisseria gonorrhoeae and Chlamydia trachomatis. There are no published data of the burden of urethral discharge among men in Fiji. To evaluate urethral discharge among men to determine the incidence, the frequency of recurrence and reported at-risk behaviour. We conducted a retrospective, descriptive study of clinical records of all men presenting with urethral discharge to two major reproductive health clinics. Data collected included self-reported at-risk behaviours, results of abnormal syphilis serology and antibiotics prescribed. The frequency of recurrence in the following 1-2 years of initial presentation was determined along with microbiological findings from urethral swab in this group. A total of 748 males presented with urethral discharge to the clinic in one year. This represents an incidence rate of at least 295 per 100,000 adult males per year in the study population. Within the next 1-2 years of the initial presentation, 102 (14%) of these re-presented out of which 42 had urethral swab taken for etiological diagnosis. The commonest isolate was Neisseria gonorrhoeae. Results of syphilis tests were available for 560 (75%) of patients and 29 (5%) were positive. Recurrence was not associated with self-reported at-risk behaviours. The incidence of urethral discharge among males in Fiji is very high and prevention strategies are urgently needed.

  11. Modification of the Steel Surface Treated by a Volume Discharge Plasma in Nitrogen at Atmospheric Pressure

    Science.gov (United States)

    Erofeev, M. V.; Shulepov, M. A.; Ivanov, Yu. F.; Oskomov, K. V.; Tarasenko, V. F.

    2016-03-01

    Effect of volume discharge plasma initiated by an avalanche electron beam on the composition, structure, and properties of the surface steel layer is investigated. Voltage pulses with incident wave amplitude up to 30 kV, full width at half maximum of about 4 ns, and wave front of about 2.5 ns were applied to the gap with an inhomogeneous electric field. Changes indicating the hardening effect of the volume discharge initiated by an avalanche electron beam are revealed in St3-grade steel specimens treated by the discharge of this type.

  12. Analysis of the Plasma Properties Affected by Magnetic Confinement with Special Emphasis on Helicon Discharges

    International Nuclear Information System (INIS)

    Cheng Yuguo; Cheng Mousen; Wang Moge; Yang Xiong; Li Xiaokang

    2014-01-01

    A one-dimensional radial non-uniform fluid model is employed to study plasma behaviors with special emphasis laid on helicon discharges. The plasma density n e , electron temperature T e , electron azimuthal and radial drift velocities are investigated in terms of the plasma radius r p , magnetic field intensity B 0 and gas pressure p 0 , by assuming radial ambipolar diffusion and negligible ion cyclotron movement. The results show that the magnetic confinement plays an important role in the discharge equilibrium, especially at low pressure, which significantly reduces T e compared with the case of a negligible magnetic field effect, and higher B 0 leads to a greater average plasma density. T e shows little variations in the plasma density range of 10 11 cm −3 –10 13 cm −3 for p 0 < 3.0 mTorr. Comparison of the simulation results with experiments suggests that the model can make reasonable predictions of T e in low pressure helicon discharges. (low temperature plasma)

  13. High performance discharges and capabilities in Alcator C-Mod

    International Nuclear Information System (INIS)

    Porkolab, M.

    1996-01-01

    Alcator C-Mod is a compact, diverted, shaped, high magnetic field (B = 9 T) tokamak operating at the Massachusetts Institute of Technology Plasma Fusion Center. The machine interior is all metallic, and the walls and divertor region are covered with molybdenum tiles. The vacuum vessel is a continuous, thick wall stainless steel construction, prototypical of future fusion devices (e.g., ITER). Typical discharge cleaning utilizes ECDC, or electron-cyclotron discharge cleaning, in the steady state at low magnetic field (0.0875 T). While its dimensions are compact (R = 0.67 m, a = 0.22 m, K = 1.8), C-Mod is designed to operate up to 2.5 MA at 9.0 T magnetic field. To present date the machine has operated at currents up to 1.5 MA at B = 5.3 T, and magnetic fields up to 8.0 T at I p = 1.2 MA. Due to the high current density, line average densities of 4.0 x 10 20 m -3 are obtained with gas fueling, and peak densities in excess of 1.0 x 10 21 m -3 have been obtained with pellet fueling. Typical pulse lengths are up to 2.0 seconds, with a flat-top of typically 1.0 sec. Presently the device is equipped with 4.0 MW of ICRF heating power operating at 80 MHz, but this capability is being upgraded to 8.0 MW with the addition of 4.0 MW of tunable ICRF power operating at 40.80 MHz. A 20 pellet/pulse deuterium injector is operational, and a 4 pellet Li injector is also operational. To reduce the influx of metallic impurities during high power operation, recently boronization of the machine interior was begun prior to plasma discharges, this allowed plasma operation with full auxiliary power capability without excessive radiative power losses from the plasma core. 7 refs

  14. Recharge and discharge calculations to characterize the groundwater hydrologic balance

    International Nuclear Information System (INIS)

    Liddle, R.G.

    1998-01-01

    Several methods are presented to quantify the ground water component of the hydrologic balance; including (1) hydrograph separation techniques, (2) water budget calculations, (3) spoil discharge techniques, and (4) underground mine inflow studies. Stream hydrograph analysis was used to calculate natural groundwater recharge and discharge rates. Yearly continuous discharge hydrographs were obtained for 16 watersheds in the Cumberland Plateau area of Tennessee. Baseflow was separated from storm runoff using computerized hydrograph analysis techniques developed by the USGS. The programs RECESS, RORA, and PART were used to develop master recession curves, calculate ground water recharge, and ground water discharge respectively. Station records ranged from 1 year of data to 60 years of data with areas of 0.67 to 402 square miles. Calculated recharge ranged from 7 to 28 inches of precipitation while ground water discharge ranged from 6 to 25 inches. Baseflow ranged from 36 to 69% of total flow. For sites with more than 4 years of data the median recharge was 20 inches/year and the 95% confidence interval for the median was 16.4 to 23.8 inches of recharge. Water budget calculations were also developed independently by a mining company in southern Tennessee. Results showed about 19 inches of recharge is available on a yearly basis. A third method used spoil water discharge measurements to calculate average recharge rate to the mine. Results showed 21.5 inches of recharge for this relatively flat area strip mine. In a further analysis it was shown that premining soil recharge rates of 19 inches consisted of about 17 inches of interflow and 2 inches of deep aquifer recharge while postmining recharge to the spoils had almost no interflow component. OSM also evaluated underground mine inflow data from northeast Tennessee and southeast Kentucky. This empirical data showed from 0.38 to 1.26 gallons per minute discharge per unit acreage of underground workings. This is the

  15. A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin

    Science.gov (United States)

    Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim

    2015-01-01

    Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511

  16. Studies of the disruption prevention by ECRH at plasma current rise stage in limiter discharges/Possibility of an internal transport barrier producing under dominating electron transport in the T-10 tokamak

    International Nuclear Information System (INIS)

    Alikaev, V.V.; Borshegovskij, A.A.; Chistyakov, V.V.

    2001-01-01

    'Studies of the Disruption Prevention by ECRH at Plasma Current Rise Stage in Limiter Discharges' - Studies of disruption prevention by means of ECRH in T-10 at the plasma current rise phase in limiter discharges with circular plasma cross-section were performed. Reliable disruption prevention by ECRH at HF power (P HF ) min level equal to 20% of ohmic heating power P OH was demonstrated. m/n=2/1 mode MHD-activity developed before disruption (with characteristic time ∼ 120 ms) can be considered as disruption precursor and can be used in a feedback system. 'Possibility of an Internal Transport Barrier Producing under Dominating Electron Transport in the T-10 Tokamak' - The reversed shear experiments were carried out on T-10 at the HF power up to 1MW. The reversed shear in the core was produced by on-axis ECCD in direction opposite to the plasma current. There are no obvious signs of Internal Transport Barriers formation under condition when high-k turbulence determines the electron transport. (author)

  17. Factors associated with discharge to home versus discharge to institutional care after inpatient stroke rehabilitation.

    Science.gov (United States)

    Nguyen, Vu Q C; PrvuBettger, Janet; Guerrier, Tami; Hirsch, Mark A; Thomas, J George; Pugh, Terrence M; Rhoads, Charles F

    2015-07-01

    To examine sociodemographic and clinical characteristics independently associated with discharge home compared with discharge to a skilled nursing facility (SNF) after acute inpatient rehabilitation. Retrospective cohort study. Three tertiary accredited acute care rehabilitation facilities. Adult patients with stroke (N=2085). Not applicable. Not applicable. Of 2085 patients with stroke treated at 3 centers over a 4-year period, 78.2% (n=1631) were discharged home and 21.8% (n=454) discharged to an SNF. Findings from a multivariable logistic regression analysis indicated that patients were less likely to be discharged home if they were older (odds ratio [OR], .98; 95% confidence interval [CI], .96-.99), separated or divorced (compared with married; OR, .61; 95% CI, .48-.79), or with Medicare health insurance (compared with private insurance; OR, .69; 95% CI, .55-.88), or had dysphagia (OR, .83; 95% CI, .71-.98) or cognitive deficits (OR, .79; 95% CI, .77-.81). The odds of being discharged home were higher for those admitted with a higher motor FIM score (OR, 1.10; 95% CI, 1.09-1.11). The following were not associated with discharge disposition: sex, race, prestroke vocational status, availability of secondary health insurance, number of days from stroke onset to rehabilitation facility admission, stroke type, impairment group, cognitive FIM on admission, other stroke deficits (aphasia, ataxia, neglect, or speech disturbance), stroke complications of hyponatremia or urinary tract infection, or comorbid conditions. One in 5 patients with stroke were discharged to an SNF after inpatient rehabilitation. On admission, several sociodemographic and clinical characteristics were identified that could be considered as important factors in early discussions for discharge planning. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Granular discharge rate for submerged hoppers

    Directory of Open Access Journals (Sweden)

    T. J. Wilson

    2014-10-01

    Full Text Available The discharge of spherical grains from a hole in the bottom of a right circular cylinder is measured with the entire system underwater. We find that the discharge rate depends on filling height, in contrast to the well-known case of dry non-cohesive grains. It is further surprising that the rate increases up to about twenty five percent, as the hopper empties and the granular pressure head decreases. For deep filling, where the discharge rate is constant, we measure the behavior as a function of both grain and hole diameters. The discharge rate scale is set by the product of hole area and the terminal falling speed of isolated grains. But there is a small-hole cutoff of about two and half grain diameters, which is larger than the analogous cutoff in the Beverloo equation for dry grains. Received: 11 September 2014, Accepted: 10 October 2014; Reviewed by: L. Staron, CNRS, Universite Pierre et Marie Curie, Institut Le Rond d'Alembert, Paris, France; Edited by: L. A. Pugnaloni; DOI: http://dx.doi.org/10.4279/PIP.060009 Cite as: T J Wilson, C R Pfeifer, N Meysingier, D J Durian, Papers in Physics 6, 060009 (2014

  19. Electrolysis Processes in D.C. Corona Discharges in Humid Air

    Science.gov (United States)

    Lelièvre, J.; Dubreuil, N.; Brisset, J.-L.

    1995-04-01

    Aqueous solutions exposed to the flux of the neutrals emitted in a d.c. point-to-plane corona discharge in air enriched with NO-3 and NO-2 anions as the matching counter-ions of the protons. The nitrate concentration continuously increases with the treatment time while that of the nitrites presents a maximum. Both concentrations are increasing functions of the current intensity and the exposure time. These results are examined in terms of successive electrochemical reactions and involve oxidation and reduction reactions at each electrode. L'exposition d'une solution aqueuse aux neutres d'une décharge couronne pointe-plan continue établie dans l'air humide fait apparaître en solution des ions nitrites et nitrates qui équilibrent la formation des protons. La concentration en nitrates croît continûment tandis que celle des nitrites présente un maximum. Un mécanisme d'oxydations successives est proposé; il implique des réactions électrochimiques à chaque électrode et rend compte que la décharge négative engendre des concentrations en nitrite supérieures à la décharge positive. Un développement du modèle concourt à expliquer la différence d'effets observés pour des décharges positives ou négatives selon la nature du gaz plasmagène.

  20. Constructive and thermal design of a core fast discharge

    International Nuclear Information System (INIS)

    Schroer, H.

    1979-08-01

    The present study is concerned with the development and thermal design of a fast discharge system for balls for the PR 3000 MWsub(th) process heat reactor. The term 'fast discharge system for balls' denotes a very short-time discharge procedure of the entire core contents, i.e. the flowing out of the fuel elements due to gravity into a receiver tank underneath the prestressed-concrete vessel. From a safety-engineering point of view, the fast discharge system for balls constitutes an additional possibility of active decay heat removal, besides the multiply redundant and diversitary reactor protection system, serving to further reduce the remaining residual risk. A fast discharge system for balls, however, is to be used only in the event of all the other possibilities of active decay heat removal having failed and when the maximum permissible temperatures for particularly exposed primary circuit components have been reached. However, the application range of such a system is restricted exclusively to high-temperature reactors with spherical fuel elements; the procedure cannot be applied to other reactor systems because of the rigidly fixed position of the fuel elements inside the core and for reasons of fuel element geometry. Besides the purpose of application, the influence of in-core temperature development on the possible actuation of the fast discharge system is being described in particular detail. This is followed by a description of the structural and thermal design of three specific major components, i.e. the piping system, shut-off devices and fuel element receiver tank, which will have to be installed additionally for the implementation of a fast discharge system for balls as compared to previous plant concepts. (orig.) [de

  1. Two-year survival of glass ionomer sealanTs placed as parT of ...

    African Journals Online (AJOL)

    2010-09-09

    Sep 9, 2010 ... Two-year survival of glass ionomer sealanTs placed as parT of proximal aTraumaTic. resToraTive ... absTracT. Objective: To evaluate after two years, the survival rate of glass ionomer cement (gic) ... or symptoms of periodontal disease, and clinically the ..... saliva contamination on the bond of dentine resin-.

  2. The effect of coupling hydrologic and hydrodynamic models on probable maximum flood estimation

    Science.gov (United States)

    Felder, Guido; Zischg, Andreas; Weingartner, Rolf

    2017-07-01

    Deterministic rainfall-runoff modelling usually assumes stationary hydrological system, as model parameters are calibrated with and therefore dependant on observed data. However, runoff processes are probably not stationary in the case of a probable maximum flood (PMF) where discharge greatly exceeds observed flood peaks. Developing hydrodynamic models and using them to build coupled hydrologic-hydrodynamic models can potentially improve the plausibility of PMF estimations. This study aims to assess the potential benefits and constraints of coupled modelling compared to standard deterministic hydrologic modelling when it comes to PMF estimation. The two modelling approaches are applied using a set of 100 spatio-temporal probable maximum precipitation (PMP) distribution scenarios. The resulting hydrographs, the resulting peak discharges as well as the reliability and the plausibility of the estimates are evaluated. The discussion of the results shows that coupling hydrologic and hydrodynamic models substantially improves the physical plausibility of PMF modelling, although both modelling approaches lead to PMF estimations for the catchment outlet that fall within a similar range. Using a coupled model is particularly suggested in cases where considerable flood-prone areas are situated within a catchment.

  3. Electrohydraulic Discharges and Nonthermal Plasma for Water Treatment

    Czech Academy of Sciences Publication Activity Database

    Locke, B.R.; Sato, M.; Hoffman, M.R.; Chang, J.S.; Šunka, Pavel

    2006-01-01

    Roč. 45, č. 1 (2006), s. 882-905 ISSN 0888-5885 Institutional research plan: CEZ:AV0Z20430508 Keywords : Electrical discharges * water cleaning * environmental applications * liquid phase reactor Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.518, year: 2006

  4. Computing discharge using the index velocity method

    Science.gov (United States)

    Levesque, Victor A.; Oberg, Kevin A.

    2012-01-01

    Application of the index velocity method for computing continuous records of discharge has become increasingly common, especially since the introduction of low-cost acoustic Doppler velocity meters (ADVMs) in 1997. Presently (2011), the index velocity method is being used to compute discharge records for approximately 470 gaging stations operated and maintained by the U.S. Geological Survey. The purpose of this report is to document and describe techniques for computing discharge records using the index velocity method. Computing discharge using the index velocity method differs from the traditional stage-discharge method by separating velocity and area into two ratings—the index velocity rating and the stage-area rating. The outputs from each of these ratings, mean channel velocity (V) and cross-sectional area (A), are then multiplied together to compute a discharge. For the index velocity method, V is a function of such parameters as streamwise velocity, stage, cross-stream velocity, and velocity head, and A is a function of stage and cross-section shape. The index velocity method can be used at locations where stage-discharge methods are used, but it is especially appropriate when more than one specific discharge can be measured for a specific stage. After the ADVM is selected, installed, and configured, the stage-area rating and the index velocity rating must be developed. A standard cross section is identified and surveyed in order to develop the stage-area rating. The standard cross section should be surveyed every year for the first 3 years of operation and thereafter at a lesser frequency, depending on the susceptibility of the cross section to change. Periodic measurements of discharge are used to calibrate and validate the index rating for the range of conditions experienced at the gaging station. Data from discharge measurements, ADVMs, and stage sensors are compiled for index-rating analysis. Index ratings are developed by means of regression

  5. Effects of a pulsed operation on ozone production in dielectric barrier air discharges

    OpenAIRE

    Ruggero Barni; Ilaria Biganzoli; Elisa Dell’Orto; Claudia Riccardi

    2014-01-01

    We have performed an experimental investigation of ozone production in a pulsed dielectric barrier discharge (DBD) reactor. Measurements of ozone in the gas-phase as a function of the power level show that in continuous mode a maximum concentration is achieved before a decrease presumably connected with gas-phase heating. When the reactor is employed in pulsed mode, by applying a definite duty cycle, a strong increase in ozone concentration is generally observed, with a maximum which happens...

  6. Seasonal forecasting of discharge for the Raccoon River, Iowa

    Science.gov (United States)

    Slater, Louise; Villarini, Gabriele; Bradley, Allen; Vecchi, Gabriel

    2016-04-01

    The state of Iowa (central United States) is regularly afflicted by severe natural hazards such as the 2008/2013 floods and the 2012 drought. To improve preparedness for these catastrophic events and allow Iowans to make more informed decisions about the most suitable water management strategies, we have developed a framework for medium to long range probabilistic seasonal streamflow forecasting for the Raccoon River at Van Meter, a 8900-km2 catchment located in central-western Iowa. Our flow forecasts use statistical models to predict seasonal discharge for low to high flows, with lead forecasting times ranging from one to ten months. Historical measurements of daily discharge are obtained from the U.S. Geological Survey (USGS) at the Van Meter stream gage, and used to compute quantile time series from minimum to maximum seasonal flow. The model is forced with basin-averaged total seasonal precipitation records from the PRISM Climate Group and annual row crop production acreage from the U.S. Department of Agriculture's National Agricultural Statistics Services database. For the forecasts, we use corn and soybean production from the previous year (persistence forecast) as a proxy for the impacts of agricultural practices on streamflow. The monthly precipitation forecasts are provided by eight Global Climate Models (GCMs) from the North American Multi-Model Ensemble (NMME), with lead times ranging from 0.5 to 11.5 months, and a resolution of 1 decimal degree. Additionally, precipitation from the month preceding each season is used to characterize antecedent soil moisture conditions. The accuracy of our modelled (1927-2015) and forecasted (2001-2015) discharge values is assessed by comparison with the observed USGS data. We explore the sensitivity of forecast skill over the full range of lead times, flow quantiles, forecast seasons, and with each GCM. Forecast skill is also examined using different formulations of the statistical models, as well as NMME forecast

  7. Discharge, sediment, and water chemistry in Clear Creek, western Nevada, water years 2013–16

    Science.gov (United States)

    Huntington, Jena M.; Riddle, Daniel J.; Paul, Angela P.

    2018-05-01

    Clear Creek is a small stream that drains the eastern Carson Range near Lake Tahoe, flows roughly parallel to the Highway 50 corridor, and discharges to the Carson River near Carson City, Nevada. Historical and ongoing development in the drainage basin is thought to be affecting Clear Creek and its sediment-transport characteristics. Previous studies from water years (WYs) 2004 to 2007 and from 2010 to 2012 evaluated discharge, selected water-quality parameters, and suspended-sediment concentrations, loads, and yields at three Clear Creek sampling sites. This report serves as a continuation of the data collection and analyses of the Clear Creek discharge regime and associated water-chemistry and sediment concentrations and loads during WYs 2013–16.Total annual sediment loads ranged from 870 to 5,300 tons during WYs 2004–07, from 320 to 1,770 tons during WYs 2010–12, and from 50 to 200 tons during WYs 2013–16. Ranges in annual loads during the three study periods were not significantly different; however, total loads were greater during 2004–07 than they were during 2013–16. Annual suspended-sediment loads in WYs 2013–16 showed no significant change since WYs 2010–12 at sites 1 (U.S. Geological Survey reference site 10310485; Clear Creek above Highway 50, near Spooner Summit, Nevada) or 2 (U.S. Geological Survey streamgage 10310500; Clear Creek above Highway 50, near Spooner Summit, Nevada), but significantly lower loads at site 3 (U.S. Geological Survey site 10310518; Clear Creek at Fuji Park, at Carson City, Nevada), supporting the theory of sediment deposition between sites 2 and 3 where the stream gradient becomes more gradual. Currently, a threshold discharge of about 3.3 cubic feet per second is required to mobilize streambed sediment (bedload) from site 2 in Clear Creek. Mean daily discharge was significantly lower in 2010–12 than in 2004–07 and also significantly lower in 2013–16 than in 2010–12. During this study, lower bedload, and

  8. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  9. Analysis of Partial Discharge Activity for Evaluation of the State of High Power Electric Generators Stator Windings

    Directory of Open Access Journals (Sweden)

    Dumitrescu Sorin

    2016-08-01

    Full Text Available The paper shows the importance of trending of partial discharge activity in assessing the insulation condition. It is presented the principle of the measurement method and the quantities that characterize partial discharges and also the criteria utilized for the assessement of the insulation condition of the hydrogenerators. Results of the measurements made on several hydrogenerators are presented, like the variation with time of the two main quantities that characterize the partial discharges, maximum magnitude, Qm and the normalized quantity, NQN over a period of about 10 years. Further, a classification of the insulation condition by 3 main and 2 intermediary categories and the definition of these categories are given. The criteria used for the assessment of the insulation condition are presented in the form of a table: quantitative criteria by the ± NQN and ± Qm values and qualitative criteria for the analysis of the 2D and 3D diagrams. At the end of each set of measurements, an analyze of the insulation condition annual evaluation is made, also a verdict is put, and of course, the recommendations made relating to the maintenance and the decisions that have been taken. The paper ends with several considerations on the method of on-line partial discharges and especially, on the conditions for valid trending activity in time.

  10. Incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients

    Directory of Open Access Journals (Sweden)

    Ruengorn C

    2011-11-01

    Full Text Available Chidchanok Ruengorn1, Kittipong Sanichwankul2, Wirat Niwatananun3, Suwat Mahatnirunkul2, Wanida Pumpaisalchai2, Jayanton Patumanond11Clinical Epidemiology Unit, Faculty of Medicine, Chiang Mai University; 2Suanprung Psychiatric Hospital; 3Department of Pharmaceutical Care, Faculty of Pharmacy, Chiang Mai University, Chiang Mai, ThailandBackground: The incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients remain uninvestigated in Thailand.Objective: To determine incidence and risk factors of suicide reattempts within 1 year after psychiatric hospital discharge in mood disorder patients.Methods: A retrospective cohort study was conducted by reviewing medical charts at Suanprung Psychiatric Hospital, Chiang Mai, Thailand. Mood disorder patients, diagnosed with the International Statistical Classification of Diseases and Related Health Problems 10th Revision codes F31.x, F32.x, and F33.x, who were admitted owing to suicide attempts between October 2006 and May 2009 were eligible. The influence of sociodemographic and clinical risk factors on suicide reattempts was investigated using Cox's proportional-hazards regression analysis.Results: Of 235 eligible mood disorder patients, 36 (15.3% reattempted suicide (median 109.5 days, range 1–322, seven (3.0% completed suicide (median 90 days, range 5–185, and 192 (84.2% neither reattempted nor completed suicide during follow-up. Of all nonfatal suicide reattempts, 14 patients (38.9% did so within 90 days. Among suicide completers, one (14.3% did so 5 days after discharge, and four (57.1% did so within 90 days. The following three risk factors explained 73.3% of the probability of suicide reattempts: over two previous suicide attempts before the index admission (adjusted hazard ratio [HR] 2.48; 95% confidence interval [CI] 1.07–5.76, being concomitantly prescribed typical and atypical antipsychotics (adjusted HR 4.79; 95% CI 1.39

  11. "I don't know what I was expecting": Home visits by neonatology fellows for infants discharged from the NICU.

    Science.gov (United States)

    Hobbs, Janice E; Tschudy, Megan M; Hussey-Gardner, Brenda; Jennings, Jacky M; Boss, Renee D

    2017-12-01

    When families transition from the neonatal intensive care unit (NICU) to the home, they become responsible for their infant's daily medical needs. Though neonatology physicians prepare families for hospital discharge, it is unclear how much clinicians understand about how their teaching and instructions translate into home care. The goal of this study was to evaluate the influence of a home visiting program on neonatology fellows' understanding of family needs soon after hospital discharge. Neonatology fellows conducted a home visit for an infant recently discharged. Before the visit, fellows reviewed their original discharge instructions, along with information about the family's neighborhood. During the home visit, fellows reviewed their discharge planning with families and discussed any challenges experienced. Afterwards, fellows completed a semi-structured interview; these transcriptions were manually coded for themes. Fellows identified several common women/family discharge challenges. These challenges fall into four domains: (1) inadequate discharge preparation, (2) medicalization of the home, (3) family adjustment to new "normal," and (4) the relevance of social context to discharge planning. Most (90%) fellows reported the home visit experience would affect their future NICU discharge practices and all agreed that home visits should be a part of neonatology training. Home visits allowed neonatology fellows to examine how their discharge preparation did, or did not, meet the family's needs. Incorporating home visits into neonatology training could help fellows learn about the relevance of social and community factors that are difficult to assess in the inpatient setting. © 2017 Wiley Periodicals, Inc.

  12. Towards a frequency-dependent discrete maximum principle for the implicit Monte Carlo equations

    Energy Technology Data Exchange (ETDEWEB)

    Wollaber, Allan B [Los Alamos National Laboratory; Larsen, Edward W [Los Alamos National Laboratory; Densmore, Jeffery D [Los Alamos National Laboratory

    2010-12-15

    It has long been known that temperature solutions of the Implicit Monte Carlo (IMC) equations can exceed the external boundary temperatures, a so-called violation of the 'maximum principle.' Previous attempts at prescribing a maximum value of the time-step size {Delta}{sub t} that is sufficient to eliminate these violations have recommended a {Delta}{sub t} that is typically too small to be used in practice and that appeared to be much too conservative when compared to numerical solutions of the IMC equations for practical problems. In this paper, we derive a new estimator for the maximum time-step size that includes the spatial-grid size {Delta}{sub x}. This explicitly demonstrates that the effect of coarsening {Delta}{sub x} is to reduce the limitation on {Delta}{sub t}, which helps explain the overly conservative nature of the earlier, grid-independent results. We demonstrate that our new time-step restriction is a much more accurate means of predicting violations of the maximum principle. We discuss how the implications of the new, grid-dependent timestep restriction can impact IMC solution algorithms.

  13. Towards a frequency-dependent discrete maximum principle for the implicit Monte Carlo equations

    International Nuclear Information System (INIS)

    Wollaber, Allan B.; Larsen, Edward W.; Densmore, Jeffery D.

    2011-01-01

    It has long been known that temperature solutions of the Implicit Monte Carlo (IMC) equations can exceed the external boundary temperatures, a so-called violation of the 'maximum principle'. Previous attempts at prescribing a maximum value of the time-step size Δ t that is sufficient to eliminate these violations have recommended a Δ t that is typically too small to be used in practice and that appeared to be much too conservative when compared to numerical solutions of the IMC equations for practical problems. In this paper, we derive a new estimator for the maximum time-step size that includes the spatial-grid size Δ x . This explicitly demonstrates that the effect of coarsening Δ x is to reduce the limitation on Δ t , which helps explain the overly conservative nature of the earlier, grid-independent results. We demonstrate that our new time-step restriction is a much more accurate means of predicting violations of the maximum principle. We discuss how the implications of the new, grid-dependent time-step restriction can impact IMC solution algorithms. (author)

  14. Double discharges in unipolar-pulsed dielectric barrier discharge xenon excimer lamps

    International Nuclear Information System (INIS)

    Liu Shuhai; Neiger, Manfred

    2003-01-01

    Excitation of dielectric barrier discharge xenon excimer lamps by unipolar short square pulses is studied in this paper. Two discharges with different polarity are excited by each voltage pulse (double discharge phenomenon). The primary discharge occurs at the top or at the rising flank of the applied unipolar square pulse, which is directly energized by the external circuit. The secondary discharge with the reversed polarity occurs at the falling flank or shortly after the falling flank end (zero external voltage) depending on the pulse width, which is energized by the energy stored by memory charges deposited by the primary discharge. Fast-speed ICCD imaging shows the primary discharge has a conic discharge appearance with a channel broadening on the anode side. This channel broadening increases with increasing the pulse top level. Only the anode-side surface discharge is observed in the primary discharge. The surface discharge on the cathode side which is present in bipolar sine voltage excitation is not observed. On the contrary, the secondary discharge has only the cathode-side surface discharge. The surface discharge on the anode side is not observed. The secondary discharge is much more diffuse than the primary discharge. Time-resolved emission measurement of double discharges show the secondary discharge emits more VUV xenon excimer radiation but less infrared (IR) xenon atomic emission than the primary discharge. It was found that the IR xenon atomic emission from the secondary discharge can be reduced by shortening the pulse width. The energy efficiency of unipolar-pulsed xenon excimer lamps (the overall energy efficiency of double discharges) is much higher than that obtained under bipolar sine wave excitation. The output VUV spectrum under unipolar pulse excitation is found to be identical to that under sine wave excitation and independent of injected electric power

  15. Impact of electrode geometry on an atmospheric pressure surface barrier discharge

    Science.gov (United States)

    Hasan, M. I.; Morabit, Y.; Dickenson, A.; Walsh, J. L.

    2017-06-01

    Several of the key characteristics of an atmospheric pressure surface barrier discharge (SBD) are heavily dependent on the geometrical configuration of the plasma generating electrodes. This paper reveals that increasing the surface area of an SBD device by reducing the gaps within the electrodes can have major and unforeseen consequence on the discharge properties. It is experimentally demonstrated that a critical limit exists when reducing the diameter of a circular electrode gap below 5 mm, beyond which the required breakdown voltage increases exponentially and the power deposited in the discharge is impeded. Using a numerical model, it is shown that a reduced electrode gap diameter yields a decrease in the voltage difference between the electrode and dielectric surface, thus lowering the maximum electric field. This study indicates a link between the electrode geometry and the nature of the reactive chemistry produced in the plasma, findings which have wide-reaching implications for many applications where multiple closely packed surface barrier discharges are employed to achieve uniform and large area plasma processing.

  16. Change of flood risk under climate change based on Discharge Probability Index in Japan

    Science.gov (United States)

    Nitta, T.; Yoshimura, K.; Kanae, S.; Oki, T.

    2010-12-01

    Water-related disasters under the climate change have recently gained considerable interest, and there have been many studies referring to flood risk at the global scale (e.g. Milly et al., 2002; Hirabayashi et al., 2008). In order to build adaptive capacity, however, regional impact evaluation is needed. We thus focus on the flood risk over Japan in the present study. The output from the Regional Climate Model 20 (RCM20), which was developed by the Meteorological Research Institute, was used. The data was first compared with observed data based on Automated Meteorological Data Acquisition System and ground weather observations, and the model biases were corrected using the ratio and difference of the 20-year mean values. The bias-corrected RCM20 atmospheric data were then forced to run a land surface model and a river routing model (Yoshimura et al., 2007; Ngo-Duc, T. et al. 2007) to simulate river discharge during 1981-2000, 2031-2050, and 2081-2100. Simulated river discharge was converted to Discharge Probability Index (DPI), which was proposed by Yoshimura et al based on a statistical approach. The bias and uncertainty of the models are already taken into account in the concept of DPI, so that DPI serves as a good indicator of flood risk. We estimated the statistical parameters for DPI using the river discharge for 1981-2000 with an assumption that the parameters stay the same in the different climate periods. We then evaluated the occurrence of flood events corresponding to DPI categories in each 20 years and averaged them in 9 regions. The results indicate that low DPI flood events (return period of 2 years) will become more frequent in 2031-2050 and high DPI flood events (return period of 200 years) will become more frequent in 2081-2100 compared with the period of 1981-2000, though average precipitation will become larger during 2031-2050 than during 2081-2100 in most regions. It reflects the increased extreme precipitation during 2081-2100.

  17. Critical discharge of fluids and gases

    International Nuclear Information System (INIS)

    Seewald, Michael

    2012-01-01

    The thermal hydraulic relations during discharge of fluids and gases are complex and a closed solution does not seem to be available. For the modeling of leakage accidents in nuclear power plants basic considerations are suitable for statements on the maximum mass flow, and thus the leak rate. The maximum mass flow is reached when the critical velocity is reached in the smallest cross section. This allows the appropriate design of safety systems for one-phase and two-phase flows. For German NPP simulators the hydrodynamics simulation program RELAP5-3D is used. The simulator center operates a 1:10 scale gas model of a two-loop PWR type reactor. The observable phenomena have occurred in nuclear power plants. The characteristics for a visualization of two-phase flows are not available in the simulation software and have to be added by correlations with experimental results. The realization of expectations on digital visualization techniques is discussed.

  18. Formation of self-organized anode patterns in arc discharge simulations

    International Nuclear Information System (INIS)

    Trelles, Juan Pablo

    2013-01-01

    Pattern formation and self-organization are phenomena commonly observed experimentally in diverse types of plasma systems, including atmospheric-pressure electric arc discharges. However, numerical simulations reproducing anode pattern formation in arc discharges have proven exceedingly elusive. Time-dependent three-dimensional thermodynamic non-equilibrium simulations reveal the spontaneous formation of self-organized patterns of anode attachment spots in the free-burning arc, a canonical thermal plasma flow established by a constant dc current between an axi-symmetric electrode configuration in the absence of external forcing. The number of spots, their size and distribution within the pattern depend on the applied total current and on the resolution of the spatial discretization, whereas the main properties of the plasma flow, such as maximum temperatures, velocity and voltage drop, depend only on the former. The sensibility of the solution to the spatial discretization stresses the computational requirements for comprehensive arc discharge simulations. The obtained anode patterns qualitatively agree with experimental observations and confirm that the spots originate at the fringes of the arc–anode attachment. The results imply that heavy-species–electron energy equilibration, in addition to thermal instability, has a dominant role in the formation of anode spots in arc discharges. (paper)

  19. Statistical Bias in Maximum Likelihood Estimators of Item Parameters.

    Science.gov (United States)

    1982-04-01

    34 a> E r’r~e r ,C Ie I# ne,..,.rVi rnd Id.,flfv b1 - bindk numb.r) I; ,t-i i-cd I ’ tiie bias in the maximum likelihood ,st i- i;, ’ t iIeiIrs in...NTC, IL 60088 Psychometric Laboratory University of North Carolina I ERIC Facility-Acquisitions Davie Hall 013A 4833 Rugby Avenue Chapel Hill, NC

  20. Summary of experimental core turbulence characteristics in ohmic and electron cyclotron resonance heated discharges in T-10 tokamak plasmas

    International Nuclear Information System (INIS)

    Vershkov, V.A.; Shelukhin, D.A.; Soldatov, S.V.; Urazbaev, A.O.; Grashin, S.A.; Eliseev, L.G.; Melnikov, A.V.

    2005-01-01

    This report summarizes the results of experimental turbulence investigations carried out at T-10 for more than 10 years. The turbulence characteristics were investigated using correlation reflectometry, multipin Langmuir probe (MLP) and heavy ion beam probe diagnostics. The reflectometry capabilities were analysed using 2D full-wave simulations and verified by direct comparison using a MLP. The ohmic and electron cyclotron resonance heated discharges show the distinct transition from the core turbulence, having complex spectral structure, to the unstructured one in the scrape-off layer. The core turbulence includes 'broad band, quasi-coherent' features, arising due to the excitation of rational surfaces with high poloidal m-numbers, with a low frequency near zero and specific oscillations at 15-30 kHz. All experimentally measured properties of low frequency and high frequency quasi-coherent oscillations are in good agreement with predictions of linear theory for the ion temperature gradient/dissipative trapped electron mode instabilities. Significant local changes in the turbulence characteristics were observed at the edge velocity shear layer and in the core near q = 1 radius after switching off the electron cyclotron resonance heating (ECRH). The local decrease in the electron heat conductivity and decrease in the turbulence level could be evidence of the formation of an electron internal transport barrier. The dynamic behaviour of the core turbulence was also investigated for the case of fast edge cooling and the beginning phase of ECRH

  1. Annual report on radioactive discharges from Winfrith and monitoring the environment 1991

    International Nuclear Information System (INIS)

    1992-05-01

    This annual report, the seventh, aims to provide full information on our discharges and environmental monitoring. The report is mainly graphical, comparing past and current levels with authorised limits, derived limits or the recommended limits of the International Commission on Radiological Protection (ICRP). Discharges from Winfrith are subject to Authorisations issued jointly by the Department of the Environment (DOE) and the Ministry of Agriculture, Fisheries and Food (MAFF). These Authorisations, one for discharges to the sea and one for discharges to the atmosphere, require that Winfrith establish a need to discharge; that we apply Best Practicable Means (BPM) to reduce our discharges; that our discharges are below set Authorised Limits; and that schedules of effluent and environmental monitoring are established. As a 'back stop', discharges at the limits must not result in doses to the most potentially exposed part of the local population - the critical group -exceeding 0.5 mSv per year. The limit recommended by the International Commission on Radiological Protection (ICRP) for dose to a member of the general public is 1.0 mSv per year. In September 1990 Winfrith's Steam Generating Heavy Water Reactor (SGHWR) was shut down therefore the pattern of discharges for 1991 differs from previous years. Discharges are generally reduced resulting in an even lower dose to the critical group, well below 1% of the ICRP limit and much less than 1% of the UK average natural background dose. (author)

  2. Maximum principles for boundary-degenerate linear parabolic differential operators

    OpenAIRE

    Feehan, Paul M. N.

    2013-01-01

    We develop weak and strong maximum principles for boundary-degenerate, linear, parabolic, second-order partial differential operators, $Lu := -u_t-\\tr(aD^2u)-\\langle b, Du\\rangle + cu$, with \\emph{partial} Dirichlet boundary conditions. The coefficient, $a(t,x)$, is assumed to vanish along a non-empty open subset, $\\mydirac_0!\\sQ$, called the \\emph{degenerate boundary portion}, of the parabolic boundary, $\\mydirac!\\sQ$, of the domain $\\sQ\\subset\\RR^{d+1}$, while $a(t,x)$ may be non-zero at po...

  3. Local and global particle and power balance in large area capacitive discharges

    International Nuclear Information System (INIS)

    Cho, Suwon; Lieberman, M A

    2003-01-01

    Large area radio frequency (rf) capacitive discharges have attracted recent interest for materials etching and deposition on large area substrates. A distinguishing feature is that the radial distribution of the absorbed rf power in these discharges depends on the rf voltage across the plates, independent of the radial variation of the plasma density n(r). A reduced set of steady-state fluid equations has been used to investigate the radial variation of n and electron temperature T e . The derived equations are shown to be invariant with respect to pL and pR, where p is the pressure, L is the plate separation and R is the discharge radius, and can be further reduced to the equations of the usual global balance model when R ε , the energy relaxation length. In this limit, the ionization frequency and T e are essentially independent of radius and n can be approximately described by the usual radial profile of a zeroth-order Bessel function. When R≥λ ε , n and T e are predominantly determined by local particle and power balance, and the n and T e radial profiles are flat over most of the volume except near the radial boundary, where n falls and T e rises to account for the increased losses at the boundary. The scale length of the edge density variation in the local balance regime is shown to be proportional to the energy relaxation length

  4. HIGH PERFORMANCE STATIONARY DISCHARGES IN THE DIII-D TOKAMAK

    International Nuclear Information System (INIS)

    Luce, T.C.; Wade, M.R.; Ferron, J.R.; Politzer, P.A.; Hyatt, A.W.; Sips, A.C.C.; Murakami, M.

    2003-01-01

    Recent experiments in the DIII-D tokamak [J.L. Luxon, Nucl. Fusion 42,614 (2002)] have demonstrated high β with good confinement quality under stationary conditions. Two classes of stationary discharges are observed--low q 95 discharges with sawteeth and higher q 95 without sawteeth. The discharges are deemed stationary when the plasma conditions are maintained for times greater than the current profile relaxation time. In both cases the normalized fusion performance (β N H 89P /q 95 2 ) reaches or exceeds the value of this parameter projected for Q fus = 10 in the International Thermonuclear Experimental Reactor (ITER) design [R. Aymar, et al., Plasma Phys. Control. Fusion 44, 519 (2002)]. The presence of sawteeth reduces the maximum achievable normalized β, while confinement quality (confinement time relative to scalings) is largely independent of q 95 . Even with the reduced β limit, the normalized fusion performance maximizes at the lowest q 95 . Projections to burning plasma conditions are discussed, including the methodology of the projection and the key physics issues which still require investigation

  5. 17 CFR 240.15b7-3T - Operational capability in a Year 2000 environment.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Operational capability in a Year 2000 environment. 240.15b7-3T Section 240.15b7-3T Commodity and Securities Exchanges SECURITIES... § 240.15b7-3T Operational capability in a Year 2000 environment. (a) This section applies to every...

  6. Measuring the availability to sediments and biota of radionuclides in wastes discharged to the sea

    International Nuclear Information System (INIS)

    Nicholson, M.D.; Hunt, G.J.

    1995-01-01

    Radionuclides in waste discharged to the sea are taken up by marine sediments and organisms. The concentrations observed in these materials are determined by a complex process depending upon present and past discharges, and the rates of decay, dispersion, uptake and elimination. A simple, semi-empirical model is derived to predict current concentrations from historical discharges. An important parameter in this model is the mean availability time, the average time for which the radionuclide is effectively available to the material. Maximum likelihood estimates of the model's parameters are derived. The theory is applied to data collected in the marine environment near British Nuclear Fuels plc, Sellafield. (Author)

  7. Estimating the magnitude of annual peak discharges with recurrence intervals between 1.1 and 3.0 years for rural, unregulated streams in West Virginia

    Science.gov (United States)

    Wiley, Jeffrey B.; Atkins, John T.; Newell, Dawn A.

    2002-01-01

    Multiple and simple least-squares regression models for the log10-transformed 1.5- and 2-year recurrence intervals of peak discharges with independent variables describing the basin characteristics (log10-transformed and untransformed) for 236 streamflow-gaging stations were evaluated, and the regression residuals were plotted as areal distributions that defined three regions in West Virginia designated as East, North, and South. Regional equations for the 1.1-, 1.2-, 1.3-, 1.4-, 1.5-, 1.6-, 1.7-, 1.8-, 1.9-, 2.0-, 2.5-, and 3-year recurrence intervals of peak discharges were determined by generalized least-squares regression. Log10-transformed drainage area was the most significant independent variable for all regions. Equations developed in this study are applicable only to rural, unregulated streams within the boundaries of West Virginia. The accuracies of estimating equations are quantified by measuring the average prediction error (from 27.4 to 52.4 percent) and equivalent years of record (from 1.1 to 3.4 years).

  8. Measurements of the total energy lost per electron-ion pair lost in low-pressure inductive argon, helium, oxygen and nitrogen discharge

    International Nuclear Information System (INIS)

    Lee, Young-Kwang; Ku, Ju-Hwan; Chung, Chin-Wook

    2011-01-01

    Experimental measurements of the total energy lost per electron-ion pair lost, ε T , were performed in a low-pressure inductive atomic gases (Ar, He) and molecular gases (O 2 , N 2 ) discharge. The value of ε T was determined from a power balance based on the electropositive global (volume-averaged) model. A floating harmonic method was employed to measure ion fluxes and electron temperatures at the discharge wall. In the pressure range 5-50 mTorr, it was found that the measured ε T ranged from about 70 to 150 V for atomic gases, but from about 180 to 1300 V for molecular gases. This difference between atomic and molecular discharge is caused by additional collisional energy losses of molecular gases. For argon discharge, the stepwise ionization effect on ε T was observed at relatively high pressures. For different gases, the measured ε T was evaluated with respect to the electron temperature, and then compared with the calculation results, which were derived from collisional and kinetic energy loss. The measured ε T and their calculations showed reasonable agreement.

  9. Activation and discharge kinetics of metal hydride electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Stein Egil

    2003-07-01

    Potential step chronoamperometry and Electrochemical Impedance Spectroscopy (eis) measurements were performed on single metal hydride particles. For the {alpha}-phase, the bulk diffusion coefficient and the absorption/adsorption rate parameters were determined. Materials produced by atomisation, melt spinning and conventional casting were investigated. The melt spun and conventional cast materials were identical and the atomised material similar in composition. The particles from the cast and the melt spun material were shaped like parallelepipeds. A corresponding equation, for this geometry, for diffusion coupled to an absorption/adsorption reaction was developed. It was found that materials produced by melt spinning exhibited lower bulk diffusion (1.7E-14 m2/s) and absorption/adsorption reaction rate (1.0E-8 m/s), compared to materials produced by conventionally casting (1.1E-13 m2/s and 5.5E-8 m/s respectively). In addition, the influence of particle active surface and relative diffusion length were discussed. It was concluded that there are uncertainties connected to these properties, which may explain the large distribution in the kinetic parameters measured on metal hydride particles. Activation of metal hydride forming materials has been studied and an activation procedure, for porous electrodes, was investigated. Cathodic polarisation of the electrode during a hot alkaline surface treatment gave the maximum discharge capacity on the first discharge of the electrode. The studied materials were produced by gas atomisation and the spherical shape was retained during the activation. Both an AB{sub 5} and an AB{sub 2} alloy was successfully activated and discharge rate properties determined. The AB{sub 2} material showed a higher maximum discharge capacity, but poor rate properties, compared to the AB{sub 5} material. Reduction of surface oxides, and at the same time protection against corrosion of active metallic nickel, can explain the satisfying results of

  10. Full spatial-field visualization of gas temperature in an air micro-glow discharge by calibrated Schlieren photography

    Science.gov (United States)

    Xiong, Qing; Xu, Le; Wang, Xia; Xiong, Lin; Huang, Qinghua; Chen, Qiang; Wang, Jingang; Peng, Wenxiong; Li, Jiarui

    2018-03-01

    Gas temperature is an important basic parameter for both fundamental research and applications of plasmas. In this work, efforts were made to visualize the full spatial field of gas temperature (T g) in a microdischarge with sharp T g gradients by a method of calibrated Schlieren (CS) photography. Compared to other two typical diagnostic approaches, optical emission spectroscopy (OES) and Rayleigh scattering, the proposed CS method exhibits the ability to capture the whole field of gas temperature using a single Schlieren image, even the discharge is of non-luminous zones like Faraday dark space (FDS). The image shows that the T g field in the studied micro-glow air discharge expands quickly with the increase of discharge currents, especially in the cathode region. The two-dimensional maps of gas temperature display a ‘W-shape’ with sharp gradients in both areas of negative and positive glows, slightly arched distributions in the positive column, and cooling zones in the FDS. The obtained T g fields show similar patterns to that of the discharge luminance. With an increase in discharge currents, more electric energy is dissipated by heating air gas and inducing constriction of the low-temperature FDS. Except in the vicinities of electrode boundaries, due to the interference from optical diffraction, the estimated gas temperature distributions are of acceptable accuracy, confirmed by the approaches of OES and UV Rayleigh scattering.

  11. National Hospital Discharge Survey: 2005 annual summary with detailed diagnosis and procedure data.

    Science.gov (United States)

    DeFrances, Carol J; Cullen, Karen A; Kozak, Lola Jean

    2007-12-01

    This report presents 2005 national estimates and selected trend data on the use of nonfederal short-stay hospitals in the United States. Estimates are provided by selected patient and hospital characteristics, diagnoses, and surgical and nonsurgical procedures performed. Estimates of diagnoses and procedures are presented according to International Classification of Diseases, Ninth Revision, Clinical Modification codes. The estimates are based on data collected through the National Hospital Discharge Survey. The survey has been conducted annually since 1965. In 2005, data were collected for approximately 375,000 discharges. Of the 473 eligible nonfederal short-stay hospitals in the sample, 444 (94 percent) responded to the survey. An estimated 34.7 million discharges from nonfederal short-stay hospitals occurred in 2005. Discharges used 165.9 million days of care and had an average length of stay of 4.8 days. Persons 65 years and over accounted for 38 percent of the hospital discharges and 44 percent of the days of care. The proportion of discharges whose status was described as routine discharge or discharged to the patient's home declined with age, from 91 percent for inpatients under 45 years of age to 41 percent for those 85 years and over. Hospitalization for malignant neoplasms decreased from 1990-2005. The hospitalization rate for asthma was the highest for children under 15 years of age and those 65 years of age and over. The rate was lowest for those 15-44 years of age. Thirty-eight percent of hospital discharges had no procedures performed, whereas 12 percent had four or more procedures performed. An episiotomy was performed during a majority of vaginal deliveries in 1980 (64 percent), but by 2005, it was performed during less than one of every five vaginal deliveries (19 percent).

  12. Lung function in 6 years old children born very preterm and fed different diets post discharge

    DEFF Research Database (Denmark)

    Toftlund, Line Hedegaard; Agertoft, Lone; Halken, Susanne

    Background: Research has shown that being born preterm may affect lung capacity later in childhood. It is though unknown if type of early nutrition influences lung capacity and the risk of developing asthma in childhood. Aim: The aim was to investigate if type of early nutrition has an impact...... on lung function and the possible risk of developing asthma among 6 year old children born very preterm. Method: A prospective, randomized, interventional multicentre study on nutrition of a preterm birth cohort has been established and described previously. The inclusion criteria were gestational age...... ≤ 32 weeks. From hospital discharge to 4 month corrected age, the children received three different types of nutrition: A: Human milk (HM) B: HM enriched with fortifier (HMF) C: Preterm formula (PF). At the age of 6 years, the children performed an occlusion test (Rocc) and a lung resistance test...

  13. Effect of an educational intervention on parental readiness for premature infant discharge from the neonatal intensive care units.

    Science.gov (United States)

    Chen, Yongfeng; Zhang, Jun; Bai, Jinbing

    2016-01-01

    To examine the effect of an educational intervention on parental readiness for premature infant discharge from neonatal intensive care units. Low readiness for discharge can result in negative healthcare outcomes for infants and their parents. However, few studies have examined the effect of discharge education programmes on parental readiness for premature infant discharge in Chinese critical care settings. A quasi-experimental study. Between October 2011-March 2012, 154 parents of premature infants were recruited from neonatal intensive care units of two tertiary hospitals in Central China. These parents were assigned to either the intervention or control group based on their entry order. Parents in the intervention group received two sessions of 60-minute discharge education along with hospital routine care; parents in the control group only received hospital routine care. Parental readiness for discharge and quality of discharge education were assessed on the day of infant discharge from neonatal intensive care units. Independent samples t-test and linear regression were used to analyse the data. Parental readiness for premature infant discharge was in the moderate level. Independent samples t-test showed that both mean scores of parental discharge readiness and discharge teaching quality from the intervention group were significantly higher than those in the control group. Linear regression analysis showed that discharge teaching quality explained 39·7% of the variance in parental readiness for premature infant discharge. Discharge education can improve parental readiness for premature infant discharge. Quality of discharge teaching can significantly predict parental readiness for premature infant discharge. © 2015 John Wiley & Sons Ltd.

  14. Novel methods for estimating lithium-ion battery state of energy and maximum available energy

    International Nuclear Information System (INIS)

    Zheng, Linfeng; Zhu, Jianguo; Wang, Guoxiu; He, Tingting; Wei, Yiying

    2016-01-01

    Highlights: • Study on temperature, current, aging dependencies of maximum available energy. • Study on the various factors dependencies of relationships between SOE and SOC. • A quantitative relationship between SOE and SOC is proposed for SOE estimation. • Estimate maximum available energy by means of moving-window energy-integral. • The robustness and feasibility of the proposed approaches are systematic evaluated. - Abstract: The battery state of energy (SOE) allows a direct determination of the ratio between the remaining and maximum available energy of a battery, which is critical for energy optimization and management in energy storage systems. In this paper, the ambient temperature, battery discharge/charge current rate and cell aging level dependencies of battery maximum available energy and SOE are comprehensively analyzed. An explicit quantitative relationship between SOE and state of charge (SOC) for LiMn_2O_4 battery cells is proposed for SOE estimation, and a moving-window energy-integral technique is incorporated to estimate battery maximum available energy. Experimental results show that the proposed approaches can estimate battery maximum available energy and SOE with high precision. The robustness of the proposed approaches against various operation conditions and cell aging levels is systematically evaluated.

  15. RF torch discharge combined with conventional burner

    International Nuclear Information System (INIS)

    Janca, J.; Tesar, C.

    1996-01-01

    The design of the combined flame-rf-plasma reactor and experimental examination of this reactor are presented. For the determination of the temperature in different parts of the combined burner plasma the methods of emission spectroscopy were used. The temperatures measured in the conventional burner reach the maximum temperature 1900 K but in the burner with the superimposed rf discharge the neutral gas temperature substantially increased up to 2600 K but also the plasma volume increases substantially. Consequently, the resident time of reactants in the reaction zone increases

  16. Emision of Cl2* molecules in a barrier discharge

    International Nuclear Information System (INIS)

    Avdeev, S M; Erofeev, M V; Sosnin, E A; Tarasenko, V F

    2008-01-01

    The energy and spectral parameters of emission of a barrier discharge in chlorine and its mixtures with inert gases are studied experimentally. The barrier discharge in chlorine was homogeneous at pressures up to ∼9 Torr and its spectrum contained the 3 Π 2g → 3 Π 2u , 3 Π 2g → 3 Σ 2u + and 1 Σ u + → 1 Σ g + bands of Cl 2 * molecules. After the addition of an inert gas, the 257.8-nm 3 Π 2g → 3 Π 2u band made the main contribution to the spectrum. The maximum efficiency and power of the Cl 2 excilamp were obtained for the chlorine-argon mixture and amounted to 0.7% and 1.3 W, respectively. (laser applications and other topics in quantum electronics)

  17. Maximum-likelihood methods for array processing based on time-frequency distributions

    Science.gov (United States)

    Zhang, Yimin; Mu, Weifeng; Amin, Moeness G.

    1999-11-01

    This paper proposes a novel time-frequency maximum likelihood (t-f ML) method for direction-of-arrival (DOA) estimation for non- stationary signals, and compares this method with conventional maximum likelihood DOA estimation techniques. Time-frequency distributions localize the signal power in the time-frequency domain, and as such enhance the effective SNR, leading to improved DOA estimation. The localization of signals with different t-f signatures permits the division of the time-frequency domain into smaller regions, each contains fewer signals than those incident on the array. The reduction of the number of signals within different time-frequency regions not only reduces the required number of sensors, but also decreases the computational load in multi- dimensional optimizations. Compared to the recently proposed time- frequency MUSIC (t-f MUSIC), the proposed t-f ML method can be applied in coherent environments, without the need to perform any type of preprocessing that is subject to both array geometry and array aperture.

  18. Effect of Electric Discharge Machining on Material Removal Rate and White Layer Composition

    Directory of Open Access Journals (Sweden)

    SHAHID MEHMOOD

    2017-01-01

    Full Text Available In this study the MRR (Material Removal Rate of the aerospace grade (2024 T6 aluminum alloy 2024 T6 has been determined with copper electrode and kerosene oil is used as dielectric liquid. Discharge energy is controlled by electric current while keeping Pulse-ON time and Pulse-OFF time as constant. The characteristics of the EDMed (Electric Discharge Machined surface are discussed. The sub-surface defect due to arcing has been explained. As the surface material of tool electrode and workpiece melts simultaneously and there are chances of the contamination of both surfaces by the contents of each other. Therefore, the EDS (Energy Dispersive Spectroscopy of the white layer and base material of the workpiece was performed by SEM (Scanning Electron Microscope at the discharge currents of 3, 6 and 12 amperes. It was conformed that the contamination of the surface of the workpiece material occurred by carbon, copper and oxygen contents. The quantitative analysis of these contents with respect to the discharge current has been presented in this paper.

  19. Parameters of the plasma of a dc pulsating discharge in a supersonic air flow

    Energy Technology Data Exchange (ETDEWEB)

    Shibkov, V. M., E-mail: shibkov@phys.msu.ru; Shibkova, L. V.; Logunov, A. A. [Moscow State University, Faculty of Physics (Russian Federation)

    2017-03-15

    A dc discharge in a cold (T = 200 K) supersonic air flow at a static pressure of 200–400 Torr was studied experimentally. The excited unsteady pulsating discharge has the form of a thin plasma channel with a diameter of ≤1 mm, stretched downstream the flow. Depending on the discharge current, the pulsation frequency varies from 800 to 1600 Hz and the electron temperature varies from 8000 to 15000 K.

  20. Deposition of protective coatings in rf organosilicon discharges

    Czech Academy of Sciences Publication Activity Database

    Zajíčková, L.; Buršíková, V.; Kučerová, Z.; Franta, D.; Dvořák, P.; Šmíd, R.; Peřina, Vratislav; Macková, Anna

    2007-01-01

    Roč. 16, č. 1 (2007), s. 123-132 ISSN 0963-0252 R&D Projects: GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z10480505 Keywords : organosilicon discharges, hardness and elastic modulus, protectove coating s Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.120, year: 2007

  1. Meteorological, stream-discharge, and water-quality data for water year 1992 from two basins in Central Nevada

    International Nuclear Information System (INIS)

    McKinley, P.W.; Oliver, T.A.

    1995-01-01

    The US Geological Survey, in cooperation with the US Department of Energy, is studying Yucca Mountain, Nevada, as a potential repository for high level nuclear waste. As part of the Yucca Mountain Site Project, the analog recharge study is providing data for the evaluation of recharge to the Yucca Mountain ground-water system given a cooler and wetter climate than currently exists. The current and climatic conditions are favorable to the isolation of radioactive waste. Because waste isolation from the accessible environment for 10,000 years is necessary, climatic change and the potential for increased ground-water recharge need to be considered as part of the characterization of the potential repository. Therefore, two small basins, measuring less than 2 square miles, were studied to determine the volume of precipitation available for recharge to ground water. The semiarid 3-Springs Basin is located to the east of Kawich Peak in the Kawich Range east of Tonopah, Nevada. Stewart Basin is a subalpine drainage basin north of Arc Dome in the Toiyabe Range north of Tonopah, Nevada. The purpose of this publication is to make available the meteorological, stream-discharge, and water-quality data collected during the study. Meteorological data collected include air temperature, soil temperature, solar radiation, and relative humidity. Stream-discharge data were collected from the surface-water outlet of each basin. Water-quality data are chemical analyses of water samples collected from surface- and ground-water sources. Each basin has a meteorological station located in the lower and upper reaches of the basin. Hydrologic records include stream-discharge and water-quality data from the lower meteorological site and water-quality data from springs within the basins

  2. T-R CYCLE CHARACTERIZATION AND IMAGING: ADVANCED DIAGNOSTIC METHODOLOGY FOR PETROLEUM RESERVOIR AND TRAP DETECTION AND DELINEATION

    Energy Technology Data Exchange (ETDEWEB)

    Ernest A. Mancini

    2004-09-24

    The principal research effort for Year 1 of the project has been T-R cycle characterization and modeling. The research focus for the first nine (9) months of Year 1 was on outcrop study, well log analysis, seismic interpretation and data integration and for the remainder of the year the emphasis has been on T-R cycle model development. Information regarding the characteristics of T-R cycles has been assembled from the study of outcrops, from well log analyses, and from seismic reflection interpretation. From these studies, stratal boundaries separating T-R cycles have been found to be useful for the recognition and delineation of these cycles. The key stratal surfaces include subaerial unconformities, shoreface ravinement surfaces, transgressive surfaces, surfaces of maximum regression, and surfaces of maximum transgression. These surfaces can be identified and mapped in surface exposures and can be recognized in well log signatures and seismic reflection profiles as discontinuities. The findings from the study of outcrop, well log, and seismic reflection data are being integrated into a database for use in constructing a model for T-R cycle development.

  3. Discharge and other hydraulic measurements for characterizing the hydraulics of Lower Congo River

    Science.gov (United States)

    Oberg, Kevin; Shelton, John M.; Gardiner, Ned; Jackson, P. Ryan

    2009-01-01

    The first direct measurements of discharge of the Lower Congo River below Malebo Pool and upstream from Kinganga, Democratic Republic of Congo (DRC) were made in July 2008 using acoustic Doppler current profilers, differential GPS, and echo sounders. These measurements were made in support of research that is attempting to understand the distribution of fish species in the Lower Congo River and reasons for separation of species within this large river. Analyses of these measurements show that the maximum depth in the Lower Congo River was in excess of 200 m and maximum water velocities were greater than 4 m/s. The discharge measured near Luozi, DRC was 35,800 m3/s, and decreased slightly beginning midway through the study. Local bedrock controls seem to have a large effect on the flow in the river, even in reaches without waterfalls and rapids. Dramatic changes in bed topography are evident in transects across the river.

  4. Bilateral cartilage T2 mapping 9 years after Mega-OATS implantation at the knee: a quantitative 3T MRI study.

    Science.gov (United States)

    Jungmann, P M; Brucker, P U; Baum, T; Link, T M; Foerschner, F; Minzlaff, P; Banke, I J; Saier, T; Imhoff, A B; Rummeny, E J; Bauer, J S

    2015-12-01

    To evaluate morphological and quantitative MR findings 9 years after autograft transfer of the posterior femoral condyle (Mega-OATS) and to correlate these findings with clinical outcomes. Quantitative MR measurements were also obtained of the contralateral knee and the utility as reference standard was investigated. Both knees of 20 patients with Mega-OATS osteochondral repair at the medial femoral condyle (MFC) were studied using 3T MRI 9 years after the procedure. MR-sequences included morphological sequences and a 2D multislice multiecho (MSME) spin echo (SE) sequence for quantitative cartilage T2 mapping. Cartilage segmentation was performed at the cartilage repair site and six additional knee compartments. Semi-quantitative MR observation of cartilage repair tissue (MOCART) scores and clinical Lysholm scores were obtained. Paired t-tests and Spearman correlations were used for statistical analysis. Global T2-values were significantly higher at ipsilateral knees compared to contralateral knees (42.1 ± 3.0 ms vs 40.4 ± 2.6 ms, P = 0.018). T2-values of the Mega-OATS site correlated significantly with MOCART scores (R = -0.64, P = 0.006). The correlations between MOCART and Lysholm scores and between absolute T2-values and Lysholm scores were not significant (P > 0.05). However, higher T2 side-to-side differences at the femoral condyles correlated significantly with more severe clinical symptoms (medial, R = -0.53, P = 0.030; lateral, R = -0.51, P = 0.038). Despite long-term survival, 9 years after Mega-OATS procedures, T2-values of the grafts were increased compared to contralateral knees. Clinical scores correlated best with T2 side-to-side differences of the femoral condyles, indicating that intraindividual adjustment may be beneficial for outcome evaluation. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  5. Independent Association Between Preoperative Cognitive Status and Discharge Location After Surgery: A Strategy to Reduce Resource Use After Surgery for Deformity.

    Science.gov (United States)

    Adogwa, Owoicho; Elsamadicy, Aladine A; Sergesketter, Amanda; Vuong, Victoria D; Moreno, Jessica; Cheng, Joseph; Karikari, Isaac O; Bagley, Carlos A

    2018-02-01

    The aim of this study is to determine whether preoperative scores on a screening measure for cognitive status (the Saint Louis University mental status examination), were associated with discharge to a location other than home in older patients undergoing surgery for deformity. Older patients (≥65 years) undergoing a planned elective spinal surgery for correction of adult degenerative scoliosis were enrolled in this study. Preoperative baseline cognition was assessed using the validated Saint Louis University mental status (SLUMS) test. SLUMS is 11 questions with a maximum of 30 points. Mild cognitive impairment was defined as a SLUMS score of 21-26 points, and severe cognitive impairment as a SLUMS score of 20 points or greater. Normal cognition was defined as a SLUMS score of 27 points or more. Postoperative length of stay and discharge location were recorded on all patients. Eighty-two subjects were included, with mean ± standard deviation age of 73.26 ± 6.08 years; 51% of patients were discharged to a facility (skilled nursing or acute rehabilitation). After adjustment for demographic variables, comorbidities, and baseline cognitive impairment, patients with preoperative cognitive impairment were 4-fold more likely to be discharged to a facility (skilled nursing or acute rehabilitation) compared with patients with normal cognitive status (odds ratio [OR], 3.93). In addition, patients who were not ambulatory before surgery were also more likely to be discharged to a facility (OR, 7.14). In geriatric patients undergoing surgery for deformity correction, cognitive screening before surgery can identify patients with impaired cognitive status who are less likely than those with normal cognitive status to return home after surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Primary chylous vaginal discharge in a 9-year-old girl: CT-lymphangiogram and MR appearance.

    Science.gov (United States)

    Shahlaee, A H; Burton, E M; Sabio, H; Plouffe, L; Teeslink, R

    1997-09-01

    Chylous reflux is a manifestation of primary or secondary lymphatic obstruction. Primary lymphatic obstruction is defined as lymphangiectasia and incompetency of lymphatic valves without an underlying cause. Lymphangiectasia resulting from trauma, neoplasm, irradiation, or inflammation characterizes secondary lymphatic obstruction. Leakage of chyle into the uterus, vagina, bladder, or rectum can occur with either primary or secondary lymphatic obstruction. We report a patient with chylous vaginal discharge, a rare presentation of primary chylous reflux syndrome. CT-lymphangiography and magnetic resonance imaging clearly depicted this disorder. To our knowledge, only 20 cases of chylous vaginal discharge have been reported previously; chylous vaginal drainage occurred in the absence of chylous uterine reflux in only three. Although this is a rare anomaly, chylous reflux should be considered in a child with chronic vaginal discharge and lower extremity swelling.

  7. Increased mortality in the year following discharge from a paediatric ward in Bissau, Guinea-Bissau

    DEFF Research Database (Denmark)

    Veirum, Jens Erik; Sodeman, Morten; Biai, Sidu

    2007-01-01

    -hospital and 12-month posthospital mortality was 20%. Compared to the mortality level in the community and controlled for other determinants of childhood mortality, children discharged from hospital had 12 times higher risk of dying during the first 2 weeks after discharge. The mortality rate ratio (MR) was 6...... for postdischarge mortality included ethnic group, housing quality and maternal education, and were similar to risk factors for community mortality. The same diagnoses that had high acute mortality, including anaemia, diarrhoea and 'other', were also associated with high postdischarge mortality. CONCLUSION......BACKGROUND: Few studies in developing countries have examined posthospital mortality and little is known about the magnitude of posthospital mortality and risk factors for long-term survival. A better understanding of the determinants of posthospital mortality could help improve discharge policies...

  8. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field.

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-06-25

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge.

  9. ?Just-in-Time? Battery Charge Depletion Control for PHEVs and E-REVs for Maximum Battery Life

    Energy Technology Data Exchange (ETDEWEB)

    DeVault, Robert C [ORNL

    2009-01-01

    Conventional methods of vehicle operation for Plug-in Hybrid Vehicles first discharge the battery to a minimum State of Charge (SOC) before switching to charge sustaining operation. This is very demanding on the battery, maximizing the number of trips ending with a depleted battery and maximizing the distance driven on a depleted battery over the vehicle s life. Several methods have been proposed to reduce the number of trips ending with a deeply discharged battery and also eliminate the need for extended driving on a depleted battery. An optimum SOC can be maintained for long battery life before discharging the battery so that the vehicle reaches an electric plug-in destination just as the battery reaches the minimum operating SOC. These Just-in-Time methods provide maximum effective battery life while getting virtually the same electricity from the grid.

  10. Nipple Discharge

    Science.gov (United States)

    ... any unexpected nipple discharge evaluated by a doctor. Nipple discharge in men under any circumstances could be a problem and needs further evaluation. One or both breasts may produce a nipple discharge, either spontaneously or when you squeeze your ...

  11. Kinetic model of vibrational relaxation in a humid-air pulsed corona discharge

    International Nuclear Information System (INIS)

    Komuro, Atsushi; Ono, Ryo; Oda, Tetsuji

    2010-01-01

    The effect of humidity on the vibrational relaxation of O 2 (v) and N 2 (v) in a humid-air pulsed corona discharge is studied using a kinetic model. We previously showed that humidity markedly increases the vibration-to-translation (V-T) rate of molecules in a humid-air pulsed corona discharge by measuring O 2 (v) density (Ono et al 2010 Plasma Sources Sci. Technol. 19 015009). In this paper, we numerically calculate the vibrational kinetics of O 2 , N 2 and H 2 O to study the reason behind the acceleration of V-T in the presence of humidity. The calculation closely reproduces the measured acceleration of V-T due to humidity, and shows that the increase in the V-T rate is caused by the fast vibration-to-vibration (V-V) processes of O 2 -H 2 O and N 2 -H 2 O and the subsequent rapid V-T process of H 2 O-H 2 O. In addition, it is shown that O atom density is also important in the vibrational kinetics owing to the rapid V-T process of O 2 -O.

  12. Use of the Charge/Discharge (C/D) ratio to aument voltage limit (V sub T) charge control in the ERBS spacecraft

    Science.gov (United States)

    Halpert, G.

    1982-01-01

    A 50-ampere hour nickel cadmium cell test pack was operated in a power profile simulating the orbit of the Earth Radiation Budget Satellite (ERBS). The objective was to determine the ability of the temperature compensated voltage limit (V sub T) charge control system to maintain energy balance in the half sine wave-type current profile expected of this mission. The four-cell pack (50 E) was tested at the Naval Weapons Support Center (NWSC) at Crane, Indiana. The ERBS evaluation test consisted of two distinct operating sequences, each having a specific purpose. The first phase was a parametric test involving the effect of V sub T level, temperature, and Beta angle on the charge/discharge (C/D) ratio, an indicator of the amount of overcharge. The second phase of testing made use of the C/D ratio limit to augment the V sub T charge limit control. When the C/D limit was reached, the current was switched from the taper mode to a C/67 (0.75 A) trickle charge. The use of an ampere hour integrator limiting the overcharge to a C/67 rate provided a fine tuning of the charge control technique which eliminated the sensitivity problems noted in the initial operating sequence.

  13. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  14. Partial discharge patterns and surface deterioration in voids in filled and unfilled epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1992-01-01

    /height analyses were performed over a period of 2400 h and showed very characteristic discharge patterns for each material combination. A unique behavior with regard to changes of pulse repetition rate and maximum apparent charge was observed for PD in alumina- and silica-filled epoxy. The void surfaces were...

  15. Particle-filtering-based estimation of maximum available power state in Lithium-Ion batteries

    International Nuclear Information System (INIS)

    Burgos-Mellado, Claudio; Orchard, Marcos E.; Kazerani, Mehrdad; Cárdenas, Roberto; Sáez, Doris

    2016-01-01

    Highlights: • Approach to estimate the state of maximum power available in Lithium-Ion battery. • Optimisation problem is formulated on the basis of a non-linear dynamic model. • Solutions of the optimisation problem are functions of state of charge estimates. • State of charge estimates computed using particle filter algorithms. - Abstract: Battery Energy Storage Systems (BESS) are important for applications related to both microgrids and electric vehicles. If BESS are used as the main energy source, then it is required to include adequate procedures for the estimation of critical variables such as the State of Charge (SoC) and the State of Health (SoH) in the design of Battery Management Systems (BMS). Furthermore, in applications where batteries are exposed to high charge and discharge rates it is also desirable to estimate the State of Maximum Power Available (SoMPA). In this regard, this paper presents a novel approach to the estimation of SoMPA in Lithium-Ion batteries. This method formulates an optimisation problem for the battery power based on a non-linear dynamic model, where the resulting solutions are functions of the SoC. In the battery model, the polarisation resistance is modelled using fuzzy rules that are function of both SoC and the discharge (charge) current. Particle filtering algorithms are used as an online estimation technique, mainly because these algorithms allow approximating the probability density functions of the SoC and SoMPA even in the case of non-Gaussian sources of uncertainty. The proposed method for SoMPA estimation is validated using the experimental data obtained from an experimental setup designed for charging and discharging the Lithium-Ion batteries.

  16. Response surface method optimization of V-shaped fin assisted latent heat thermal energy storage system during discharging process

    Directory of Open Access Journals (Sweden)

    Sina Lohrasbi

    2016-09-01

    Full Text Available Latent Heat Thermal Energy Storage Systems (LHTESS containing Phase Change Material (PCM are used to establish balance between energy supply and demand. PCMs have high latent heat but low thermal conductivity, which affects their heat transfer performance. In this paper, a novel fin array has been optimized by multi-objective Response Surface Method (RSM based on discharging process of PCM, and then this fin configuration is applied on LHTESS, and comparison between full discharging time by applying this fin array and LHTESS with other fin structures has been carried out. The employed numerical method in this paper is Standard Galerkin Finite Element Method. Adaptive grid refinement is used to solve the equations. Since the enhancement technique, which has been employed in the present study reduces the employed PCM mass, maximum energy storage capacity variations have been considered. Therefore phase change expedition and maximum energy storage capacity have been considered as the objectives of optimization and the importance of second objective is indicated which is proposed as the novelty here. Results indicate that considering maximum energy storage capacity as the objective of optimization procedure leads to efficient shape design of LHTESS. Also employing optimized V-shaped fin in LHTESS, expedites discharging process considerably in comparison with the LHTESS without fin.

  17. Temperature reconstruction and volcanic eruption signal from tree-ring width and maximum latewood density over the past 304 years in the southeastern Tibetan Plateau.

    Science.gov (United States)

    Li, Mingqi; Huang, Lei; Yin, Zhi-Yong; Shao, Xuemei

    2017-11-01

    This study presents a 304-year mean July-October maximum temperature reconstruction for the southeastern Tibetan Plateau based on both tree-ring width and maximum latewood density data. The reconstruction explained 58% of the variance in July-October maximum temperature during the calibration period (1958-2005). On the decadal scale, we identified two prominent cold periods during AD 1801-1833 and 1961-2003 and two prominent warm periods during AD 1730-1800 and 1928-1960, which are consistent with other reconstructions from the nearby region. Based on the reconstructed temperature series and volcanic eruption chronology, we found that most extreme cold years were in good agreement with major volcanic eruptions, such as 1816 after the Tambora eruption in 1815. Also, clusters of volcanic eruptions probably made the 1810s the coldest decade in the past 300 years. Our results indicated that fingerprints of major volcanic eruptions can be found in the reconstructed temperature records, while the responses of regional climate to these eruption events varied in space and time in the southeastern Tibetan Plateau.

  18. Calculation Method for the Projection of Future Spent Nuclear Fuel Discharges

    International Nuclear Information System (INIS)

    B. McLeod

    2002-01-01

    This report describes the calculation method developed for the projection of future utility spent nuclear fuel (SNF) discharges in regard to their timing, quantity, burnup, and initial enrichment. This projection method complements the utility-supplied RW-859 data on historic discharges and short-term projections of SNF discharges by providing long-term projections that complete the total life cycle of discharges for each of the current U.S. nuclear power reactors. The method was initially developed in mid-1999 to update the SNF discharge projection associated with the 1995 RW-859 utility survey (CRWMS M and O 1996). and was further developed as described in Rev. 00 of this report (CRWMS M and O 2001a). Primary input to the projection of SNF discharges is the utility projection of the next five discharges from each nuclear unit, which is provided via the revised final version of the Energy Information Administration (EIA) 1998 RW-859 utility survey (EIA 2000a). The projection calculation method is implemented via a set of Excel 97 spreadsheets. These calculations provide the interface between receipt of the utility five-discharge projections that are provided in the RW-859 survey, and the delivery of projected life-cycle SNF discharge quantities and characteristics in the format requisite for performing logistics analysis to support design of the Civilian Radioactive Waste Management System (CRWMS). Calculation method improvements described in this report include the addition of a reactor-specific maximum enrichment-based discharge burnup limit. This limit is the consequence of the enrichment limit, currently 5 percent. which is imposed as a Nuclear Regulatory Commission (NRC) license condition on nuclear fuel fabrication plants. In addition, the calculation method now includes the capability for projecting future nuclear plant power upratings, consistent with many such recent plant uprates and the prospect of additional future uprates. Finally. this report

  19. Distortion of plasma due to installation of an orifice in helium discharge positive column

    International Nuclear Information System (INIS)

    Moslehi- Fard, M.; Bidadi, H.; Khorram, S.; Sobhanian, S.; Muradov, A.H.; Jallali, H.; Shirin Pour, M.

    2003-01-01

    Complicated potential structure formed at a constriction of positive column of a DC discharge with heated cathode in He at low discharge currents is investigated. According to the potential structure, electrons and ions are accelerated by the electric field and their energy distribution functions acquire multi humped shapes. Additional maximums on distribution function quickly disappear due to collisions and radial losses. The nature of current passing through the potential structure is cleared up on the base of measured distributions. Attempt was made to calculate potential drop in DL tacking into account electron energy distribution variations

  20. Spheres of discharge of springs

    Science.gov (United States)

    Springer, Abraham E.; Stevens, Lawrence E.

    2009-02-01

    Although springs have been recognized as important, rare, and globally threatened ecosystems, there is as yet no consistent and comprehensive classification system or common lexicon for springs. In this paper, 12 spheres of discharge of springs are defined, sketched, displayed with photographs, and described relative to their hydrogeology of occurrence, and the microhabitats and ecosystems they support. A few of the spheres of discharge have been previously recognized and used by hydrogeologists for over 80 years, but others have only recently been defined geomorphologically. A comparison of these spheres of discharge to classification systems for wetlands, groundwater dependent ecosystems, karst hydrogeology, running waters, and other systems is provided. With a common lexicon for springs, hydrogeologists can provide more consistent guidance for springs ecosystem conservation, management, and restoration. As additional comprehensive inventories of the physical, biological, and cultural characteristics are conducted and analyzed, it will eventually be possible to associate spheres of discharge with discrete vegetation and aquatic invertebrate assemblages, and better understand the habitat requirements of rare or unique springs species. Given the elevated productivity and biodiversity of springs, and their highly threatened status, identification of geomorphic similarities among spring types is essential for conservation of these important ecosystems.

  1. Discharge and infection in retinoblastoma post-enucleation sockets.

    Science.gov (United States)

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients' characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients ( P socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases.

  2. Transport simulations of a density limit in radiation-dominated tokamak discharges: Profile effects

    International Nuclear Information System (INIS)

    Stotler, D.P.

    1988-06-01

    The density limit observed in tokamak experiments is thought to be due to a radiative collapse of the current channel. A transport code coupled with an MHD equilibrium routine is used to determine the detailed, self-consistent evolution of the plasma profiles in tokamak discharges with radiated power close to or equalling the input power. The present work is confined to ohmic discharges in steady state. It is found that the shape of the density profile can have a significant impact on the variation of the maximum electron density with plasma current. Analytic calculations confirm this result. 41 refs., 9 figs

  3. Transport simulations of a density limit in radiation-dominated tokamak discharges: profile effects

    International Nuclear Information System (INIS)

    Stotler, D.P.

    1988-01-01

    The density limit observed in tokamak experiments is thought to be due to a radiative collapse of the current channel. A transport code coupled with a magnetohydrodynamic (MHD) equilibrium routine is used to determine the detailed, self-consistent evolution of the plasma profiles in tokamak discharges with radiated power close to or equaling the input power. The present work is confined to Ohmic discharges in steady state. It is found that the shape of the density profile can have a significant impact on the variation of the maximum electron density with plasma current. Analytic calculations confirm this result

  4. Genital sanguineous discharge in prepuberty: a case of mullerian papilloma of vagina in a nine-year-old girl.

    Science.gov (United States)

    Tumini, Stefano; Carinci, Silvia; Anzellotti, Maria Teresa; Chiesa, Pier Luigi Lelli; Rossi, Carlo; Stuppia, Liborio; Bertelloni, Silvano; Chiarelli, Francesco

    2010-08-01

    Vaginal bleeding in prepuberty is an alarming symptom that must be carefully investigated. Among quite common causes of genital sanguineous discharge, there are rarer conditions responsible for bleeding at this age like Mullerian papilloma of the genital tract. In this report, we describe a case of Mullerian papilloma of the vagina in a 9-year-old girl. We believe in the importance of a correct clinical setting and histological definition to avoid wrong diagnosis and consequent inadequate treatments. Mullerian papilloma, a benign tumor, can in fact be treated only with local excision.

  5. Primary chylous vaginal discharge in a 9-year-old girl: CT-lymphangiogram and MR appearance

    International Nuclear Information System (INIS)

    Shahlaee, A.H.; Burton, E.M.; Sabio, H.; Plouffe, L. Jr.; Teeslink, R.

    1997-01-01

    Chylous reflux is a manifestation of primary or secondary lymphatic obstruction. Primary lymphatic obstruction is defined as lymphangiectasia and incompetency of lymphatic valves without an underlying cause. Lymphangiectasia resulting from trauma, neoplasm, irradiation, or inflammation characterizes secondary lymphatic obstruction. Leakage of chyle into the uterus, vagina, bladder, or rectum can occur with either primary or secondary lymphatic obstruction. We report a patient with chylous vaginal discharge, a rare presentation of primary chylous reflux syndrome. CT-lymphangiography and magnetic resonance imaging clearly depicted this disorder. To our knowledge, only 20 cases of chylous vaginal discharge have been reported previously; chylous vaginal drainage occurred in the absence of chylous uterine reflux in only three. Although this is a rare anomaly, chylous reflux should be considered in a child with chronic vaginal discharge and lower extremity swelling. (orig.). With 3 figs

  6. Clostridium beijerinckii mutant obtained atmospheric pressure glow discharge generates enhanced electricity in a microbial fuel cell.

    Science.gov (United States)

    Liu, Jun; Guo, Ting; Wang, Dong; Ying, Hanjie

    2015-01-01

    A Clostridium beijerinckii mutant M13 was derived from C. beijerinckii NCIMB 8052 by atmospheric pressure glow discharge. C. beijerinckii M13 generated a maximum output power density of 79.2 mW m(-2) and a maximum output voltage of 230 mV in a microbial fuel cell containing 1 g glucose l(-1) as carbon source and 0.15 g methyl viologen l(-1) as an electron carrier.

  7. Diagnostics of a negative hydrogen ion source based on a planar-coil inductively-driven discharge

    International Nuclear Information System (INIS)

    Lishev, Stiliyan St.; Shivarova, Antonia P.; Iordanov, Dimitar I.; Todorov, Dimitar T.; Demerdzhiev, Angel P.

    2013-01-01

    Recent activity on a volume-production negative-hydrogen-ion source with the design of a matrix of small-radius discharges inductively driven by a planar coil is reported. A single discharge of the matrix has been studied by employing probe-and laser-photodetachment diagnostics. The measurements have been carried out in the first - small-size - chamber of a two-chamber discharge vessel, with rf power introduced by a planar coil positioned on its front wall. The measured profiles of the negative ion density show strong axial dependence, with two maxima located at the positions corresponding to the maxima of the dc potential, where the maxima of the electron density are also located. The first maximum is in the vicinity of the rf power input and the second one is close to the interface between the two chambers of the discharge vessel.

  8. Experimental study of negative corona discharge in pure carbon dioxide and its mixtures with oxygen

    International Nuclear Information System (INIS)

    Mikoviny, T; Kocan, M; Matejcik, S; Mason, N J; Skalny, J D

    2004-01-01

    The products of a negative corona discharge in both pure CO 2 and mixtures of CO 2 + O 2 have been studied using a coaxial cylindrical electrode geometry with particular emphasis on the production of ozone. The discharge current in pure CO 2 was found to be highly sensitive to the presence of trace concentrations of molecular oxygen and to changes in the flow speed through the discharge. The effect of dissociative electron attachment to ozone on the discharge current was studied by measurements of ozone and CO production. The ozone concentration increases monotonically with increasing content of oxygen in the mixture with carbon dioxide, whereas the CO concentration exhibits a flat maximum for oxygen concentrations of around 4%. A simple kinetic model of the dominant chemical processes is described and compared with the experimental results

  9. Influence of Plantation Establishment on Discharge Characteristics in a Small Catchment of Tropical Forest

    Directory of Open Access Journals (Sweden)

    Siti Aisah Shamsuddin

    2014-01-01

    Full Text Available A study was conducted on the impact of forest clearance on discharge from newly established Hopea odorata plantations catchment (14.4 ha. The stands were two years old when this study commenced in year 2006 and the data collection was carried out for two years. The forested catchment (C3 was clear-cut during the preparation of the forest plantation and catchment C1 was left undisturbed. Discharge and rainfall were measured continuously for two years. The discharge measured from years 1997 to 2003 was used also to determine the water yield before and after forest clear-cut. This study showed that the plantation catchment is more responsive to storm with higher total water yield than in the forested catchment. The effect of forest clear cutting to discharge was clearly shown by the increment in the amount following the clear-cut activities and time taken for the recovery of the discharge back to its original state was almost three years. The peak discharge in C3 also was affected in which the biggest change was obtained during the forest clear-cutting period compared with during calibration and after clearing periods. This study is useful as basis for improving the existing guidelines on forest plantation establishment.

  10. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  11. Enhanced performance discharges in the DIII-D tokamak with lithium wall conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, G.L. [General Atomics, San Diego, CA (United States); Lazarus, E.A. [General Atomics, San Diego, CA (United States)]|[Oak Ridge National Laboratory, Oak Ridge, TN (United States); Navratil, G.A. [General Atomics, San Diego, CA (United States)]|[Columbia University, New York, NY (United States); Bastasz, R. [General Atomics, San Diego, CA (United States)]|[Sandia National Laboratories, Livermore, CA (United States); Brooks, N.H. [General Atomics, San Diego, CA (United States); Garnier, D.T. [General Atomics, San Diego, CA (United States)]|[Massachusetts Institute of Technology, Cambridge, MA (United States); Holtrop, K.L. [General Atomics, San Diego, CA (United States); Phillips, J.C. [General Atomics, San Diego, CA (United States); Marmar, E.S. [General Atomics, San Diego, CA (United States)]|[Massachusetts Institute of Technology, Cambridge, MA (United States); Taylor, T.S. [General Atomics, San Diego, CA (United States); Thomas, D.M. [General Atomics, San Diego, CA (United States); Wampler, W.R. [General Atomics, San Diego, CA (United States)]|[Sandia National Laboratories, Albuquerque, NM (United States); Whyte, D.G. [General Atomics, San Diego, CA (United States)]|[INRS - Energie et Materiaux, Varennes, Que. (Canada); West, W.P. [General Atomics, San Diego, CA (United States)

    1997-02-01

    Lithium wall conditioning has been used in a recent campaign evaluating high performance negative central shear (NCS) discharges. During this campaign, the highest values of stored energy (4.4 MJ), neutron rate (2.4 x 10{sup 16}/s), and nT{sub i}{tau} (7 x 10{sup 20} m{sup -3} keV s) achieved to date in DIII-D were obtained. High performance NCS discharges were achieved prior to beginning lithium conditioning, but it is clear that shot reproducibility and performance were improved by lithium conditioning. Central and edge oxygen concentrations were reduced after lithium conditioning. Lithium conditioning, consisting of up to four pellets injected at the end of the preceding discharge, allowed the duration of the usual inter-shot helium glow discharge to be reduced and reproducible high auxiliary power discharges, P{sub NBI}{<=}22 MW, were obtained with plasma currents up to 2.4 MA. (orig.).

  12. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge. PMID:25071294

  13. Excess Readmission vs Excess Penalties: Maximum Readmission Penalties as a Function of Socioeconomics and Geography.

    Science.gov (United States)

    Caracciolo, Chris; Parker, Devin; Marshall, Emily; Brown, Jeremiah

    2017-08-01

    The Hospital Readmission Reduction Program (HRRP) penalizes hospitals with "excess" readmissions up to 3% of Medicare reimbursement. Approximately 75% of eligible hospitals received penalties, worth an estimated $428 million, in fiscal year 2015. To identify demographic and socioeconomic disparities between matched and localized maximum-penalty and no-penalty hospitals. A case-control study in which cases included were hospitals to receive the maximum 3% penalty under the HRRP during the 2015 fiscal year. Controls were drawn from no-penalty hospitals and matched to cases by hospital characteristics (primary analysis) or geographic proximity (secondary analysis). A selectiion of 3383 US hospitals eligible for HRRP. Thirty-nine case and 39 control hospitals from the HRRP cohort. Socioeconomic status variables were collected by the American Community Survey. Hospital and health system characteristics were drawn from Centers for Medicare and Medicaid Services, American Hospital Association, and Dartmouth Atlas of Health Care. The statistical analysis was conducted using Student t tests. Thirty-nine hospitals received a maximum penalty. Relative to controls, maximum-penalty hospitals in counties with lower SES profiles are defined by increased poverty rates (19.1% vs 15.5%, = 0.015) and lower rates of high school graduation (82.2% vs 87.5%, = 0.001). County level age, sex, and ethnicity distributions were similar between cohorts. Cases were more likely than controls to be in counties with low socioeconomic status; highlighting potential unintended consequences of national benchmarks for phenomena underpinned by environmental factors; specifically, whether maximum penalties under the HRRP are a consequence of underperforming hospitals or a manifestation of underserved communities. © 2017 Society of Hospital Medicine

  14. Correlation of shoulder range of motion limitations at discharge with limitations in activities and participation one year later in persons with spinal cord injury

    NARCIS (Netherlands)

    Eriks-Hoogland, Inge E.; de Groot, Sonja; Post, Marcel W. M.; van der Woude, Lucas H. V.

    Objective: To study the correlation between limited shoulder range of motion in persons with spinal cord injury at discharge and the performance of activities, wheeling performance, transfers and participation one year later. Design: Multicentre prospective cohort study. Subjects: A total of 146

  15. Integrated discharge scenario for high-temperature helical plasma on LHD

    International Nuclear Information System (INIS)

    Nagaoka, K.; Takahashi, H.; Murakami, S.

    2014-10-01

    Discharge scenario of high temperature plasma with helical configuration has been significantly progressed. The increase of central ion temperature due to reduction of wall recycling was clearly observed. The neutral particle profile was measured with a high-dynamic range of Balmer-α spectroscopy, and the reduction of neutral density was identified after helium conditioning main discharges. The peaking of ion heating profile and the reduction of charge exchange loss of energetic ions play an important role for improvement of ion heat transport in the core. The ion ITB and electron ITB have been successfully integrated due to superposition of centrally focused electron cyclotron heating to the ion ITB plasma, and the high temperature regime of T i ∼T e has been significantly extended. The normalized temperature gradient of ion and electron (R/L T ) were observed to exceed 10, indicating the significant improvement of both ion and electron heat transports at the barrier position. The positive radial electric field was observed by heavy ion beam probe, while the negative radial electric field was observed in ion ITB plasmas. The ion temperature gradient was observed to decrease with the increase of temperature ratio (T e /T i ). This experiment demonstrated that the profile control is a key to combine ion ITB and electron ITB and have a potential to improve the performance of helical plasmas. (author)

  16. Exploring high-density baryonic matter: Maximum freeze-out density

    Energy Technology Data Exchange (ETDEWEB)

    Randrup, Joergen [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Cleymans, Jean [University of Cape Town, UCT-CERN Research Centre and Department of Physics, Rondebosch (South Africa)

    2016-08-15

    The hadronic freeze-out line is calculated in terms of the net baryon density and the energy density instead of the usual T and μ{sub B}. This analysis makes it apparent that the freeze-out density exhibits a maximum as the collision energy is varied. This maximum freeze-out density has μ{sub B} = 400 - 500 MeV, which is above the critical value, and it is reached for a fixed-target bombarding energy of 20-30 GeV/N well within the parameters of the proposed NICA collider facility. (orig.)

  17. Experimental studies of equilibrium in the toroidal Extrap T1 experiment

    International Nuclear Information System (INIS)

    Drake, J.R.; Hedin, E.R.; Karlsson, P.; Jin Li; Saetherblom, H.E.

    1989-03-01

    Experimental studies of a toroidal, high-beta plasma discharge with a non-circular cross-section are described. In Extrap T1, four toroidal, current-carrying rings outside the plasma discharge current channel produce a separatrix which bounds the plasma. Plasma currents of up to 40 kA are induced, operating with a toroidal field of up to 0.2 T. The major radius of the device is 0.45 m and the average minor radius of the current channel is about 40 mm. The discharge pulse is approximately 100 μsec long. For the discharges reported here, the peak current density on the discharge axis is about 9 MA/m 2 , which corresponds to an on-axis safety factor q o of about 0.1. The plasma density is in the range n ≅ 0.2 to 1 x 10 21 m -3 , and the electron temperature is in the range T e ≅ 10 to 30 eV. Magnetic flux plots of the experiment have been studied using magnetic probes and current and pressure profiles have been derived from the magnetic data

  18. Measurements of TFTR D-T radiation shielding efficiency

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ascione, G.; Elwood, S.; Gilbert, J.; Ku, L.P.; Levine, J.; Rule, K.; Azziz, N.; Goldhagen, P.; Hajnal, F.

    1994-11-01

    Measurements of neutron and gamma dose-equivalents were performed in the Test Cell, at the outer Test Cell wall, in nearby work areas, and out to the nearest property lines at a distance of 180 m. Argon ionization chambers, moderated 3 He proportional counters, and fission chamber detectors were used to obtain measurements of neutron and gamma dose-equivalents per D-T neutron during individual TFTR discharges. These measured neutron and gamma D-T dose-equivalents per TFTR neutron characterize the effects of local variations in material density resulting from the complex asymmetric site geometry. The measured dose-equivalents per TFTR D-T neutron and the cumulative neutron production were used to determine that the planned annual TFTR neutron production of 1 x 10 21 D-T neutrons is consistent with the design objective of limiting the total dose-equivalent at the property line, from all radiation sources and pathways, to less than 10 mrem per year

  19. Discharge characteristics of biceps brachii motor units at recruitment when older adults sustained an isometric contraction.

    Science.gov (United States)

    Pascoe, Michael A; Holmes, Matthew R; Enoka, Roger M

    2011-02-01

    The purpose of this study was to compare the discharge characteristics of motor units recruited during an isometric contraction that was sustained with the elbow flexor muscles by older adults at target forces that were less than the recruitment threshold force of each isolated motor unit. The discharge times of 27 single motor units were recorded from the biceps brachii in 11 old adults (78.8 ± 5.9 yr). The target force was set at either a relatively small (6.6 ± 3.7% maximum) or large (11.4 ± 4.5% maximum) difference below the recruitment threshold force and the contraction was sustained until the motor unit was recruited and discharged action potentials for about 60 s. The time to recruitment was longer for the large target-force difference (P = 0.001). At recruitment, the motor units discharged repetitively for both target-force differences, which contrasts with data from young adults when motor units discharged intermittently at recruitment for the large difference between recruitment threshold force and target force. The coefficient of variation (CV) for the first five interspike intervals (ISIs) increased from the small (18.7 ± 7.9) to large difference (35.0 ± 10.2%, P = 0.008) for the young adults, but did not differ for the two target force differences for the old adults (26.3 ± 14.7 to 24.0 ± 13.1%, P = 0.610). When analyzed across the discharge duration, the average CV for the ISI decreased similarly for the two target-force differences (P = 0.618) in old adults. These findings contrast with those of young adults and indicate that the integration of synaptic input during sustained contractions differs between young and old adults.

  20. Coal-fired power stations - the radiological impact of effluent discharges to atmosphere

    International Nuclear Information System (INIS)

    Camplin, W.C.

    1980-06-01

    An assessment is made of the radiological impact of atmosphere discharges from a hypothetical 2000 MWe power station sited in Great Britain. The exposure pathways considered are external irradiation from the plume and from activity deposited on the ground, inhalation of material in the plume and material resuspended from land surfaces, and ingestion of contaminated foodstuffs. The reduction in radiation exposure due to naturally-occurring 14 C by releases of stable carbon from the power station is also considered. The ingestion pathway is found to result in the highest individual doses, whereas the inhalation pathway makes the dominant contribution to collective dose. The most important radionuclides are 210 Pb, 210 Po and the thorium isotopes 232 Th, 230 Th and 228 Th. For 30 years operation of the power-station, the collective effective dose equivalent commitment truncated to 500 years is estimated to be 340 man Sv. The maximum annual committed effective dose equivalent to an individual is evaluated as 230 μSv, though it is considered improbable that this level of dose would be found in practice. (author)

  1. Reuse of discharged fuel in Bohunice-1,2 units

    International Nuclear Information System (INIS)

    Chrapciak, V.; Majercik, J.; Kacmar, M.

    2003-01-01

    During the reconstruction of Bohunice-1,2 units (1997 - 2001), their cycle lengths dropped to very short values. Because of 4-year limit to fuel residence time, refuelling with fresh 2.4 % enriched assemblies seemed to be a solution of the problem. The paper describes the implementation of a final decision to reuse 3.6 % enriched fuel discharged after 3-year irradiation in previous cycles. This decision led to a large-scale moving of discharged assemblies from spent fuel pools back to reactors (Authors)

  2. Evolution of the discharge impact assessments in the French regulation framework

    International Nuclear Information System (INIS)

    Chartier, M.; Despres, A.; Guillaume, R.; Plazanic, P.; Supervil, S.; Hubert, P.

    2000-01-01

    The French regulation on discharge authorisation procedures has been modified in 1995. The French authorities are thus committed to re-examined the discharge authorisations for all French nuclear installations. A new examination of discharge authorisations is in progress. The authorisations to discharge liquid and gaseous effluents had been granted at the time of the development of the nuclear installations (power plants, laboratories, facilities) according to a procedure defined in 1976. The recommendations of the ICRP expressed in the publication n deg 60, endorsed for the main part of them by the 1996 European, modified the concept of > for discharges, inter alia with an increased stress on optimisation. This evolution is consistent with the French low which does not recognise the right to pollute but defines a regime of authorisations which are always revocable. Consequently, the French authorities committed themselves to reductions of discharge limits as low as possible, at economically affordable cost. Since 1976, the evolutions of the principles of radiation protection for populations and of the French regulation together with the experience of 25 years of operations yielded significant changes of the approach of radiological impact assessments used in the regulation framework. This paper discuss and illustrate these changes: 1. Differences between the situation in 1976 (installations were planned) and now (most installations have operated since several years or tens of years) are first put forward: discharged activities, compositions of the effluents, variations of the discharges and their grounds are now better understood; techniques to reduce discharges have been developed. The opportunities in terms of discharge reductions and accuracy of radiological impact assessment are underlined. 2. Main characteristics of the bases of the radiological impact assessments used in the French regulation framework are then described: identification of existing reference

  3. Report on radioactive discharges and environmental monitoring at nuclear power stations during 1991

    International Nuclear Information System (INIS)

    Hurst, M.J.; Thomas, D.W.

    1992-09-01

    This report presents the details for 1991 of radioactive discharges and environmental monitoring at Nuclear Electric sites. In addition to the main section which summarises the discharges and monitoring at the Company's nuclear sites as a whole, appendices are presented covering the data in detail for individual sites. In each case the radiological impact on the general public has been estimated. Discharges generally were not substantially different from those of recent years. All radioactive effluent discharges from power stations were within authorised limits. Radiation doses to members of the public resulting from these discharges, and from direct radiation from the Stations, were in all cases less than the limit of 1 mSv per year which has been recommended by ICRP since 1985. (Author)

  4. Chronophysiological modifications of the triiodothyronine's peripheral metabolism(T3)

    International Nuclear Information System (INIS)

    Watanabe, Tomas; Degrossi, O.J.; Altschuler, Noe; Garcia del Rio, Hernan

    1984-01-01

    An interesting aspect relative to the thyroid function consists in determining the variations produced by the age. Though this relation has been referred to T 4 related with age, there are no differences about T 3 kinetics. For this purpose, different parameters were studied in 68 euthyroid controls of both sexs, in good nutritional state and normal activity, whose ages oscillate between 6 and 83 years old. A kinetic study method of single i.v. T 3 -I 125 injection was used, employing 0,5 μCi/Kg of body weight with maximum activity of 10 μCi to 10 years old; 15 μCi to 15 years old and 30 μCi above this age. Determinations of T 4 , T 3 and TSH serum by radioimmunoassay were carried out. From these studies, the following conclusions were obtained: T 4 and TSH are within the normal values, while a decrease of T 3 related with age was observed. Parallely to said decrease, a prolongation of plasmatic half time and a decrease of the daily value production, which is expressed statistically by a double exponential function are appreciated. The first one, which is of fast slope, corresponds to subjects below 10 years old and the second one, which is slower, starts from that age to the seventh decade of life. (M.E.L.) [es

  5. Plasmachemical Oxidation Processes in Hybrid Gas-Liquid Electrical Discharge Reactor

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Petr; Locke, B.R.

    2005-01-01

    Roč. 38, č. 22 (2005), s. 4074-4081 ISSN 0022-3727 Institutional research plan: CEZ:AV0Z20430508 Keywords : Corona discharge * hybrid reactor * hydroxyl radical * ozone * phenol * water treatment Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.957, year: 2005

  6. State waste discharge permit application for cooling water and condensate discharges

    Energy Technology Data Exchange (ETDEWEB)

    Haggard, R.D.

    1996-08-12

    The following presents the Categorical State Waste Discharge Permit (SWDP) Application for the Cooling Water and Condensate Discharges on the Hanford Site. This application is intended to cover existing cooling water and condensate discharges as well as similar future discharges meeting the criteria set forth in this document.

  7. Predictors of Discharge Disposition in Older Adults With Burns: A Study of the Burn Model Systems.

    Science.gov (United States)

    Pham, Tam N; Carrougher, Gretchen J; Martinez, Erin; Lezotte, Dennis; Rietschel, Carly; Holavanahalli, Radha; Kowalske, Karen; Esselman, Peter C

    2015-01-01

    Older patients with burn injury have a greater likelihood for discharge to nursing facilities. Recent research indicates that older patients discharged to nursing facilities are two to three times as likely to die within a 3-year period relative to those discharged to home. In light of these poor long-term outcomes, we conducted this study to identify predictors for discharge to independent vs nonindependent living status in older patients hospitalized for burns. We retrospectively reviewed all older adults (age ≥ 55 years) who were prospectively enrolled in a longitudinal multicenter study of outcomes from 1993 to 2011. Patient, injury, and treatment outcomes data were analyzed. Recognizing that transfer to inpatient rehabilitation may have impacted final hospital discharge disposition: we assessed the likelihood of inpatient rehabilitation stay, based on identified predictors of inpatient rehabilitation. We subsequently performed a logistic regression analysis on the clustered, propensity-matched cohort to assess associations of burn and injury characteristics on the primary outcome of final discharge status. A total of 591 patients aged ≥55 years were treated and discharged alive from three participating U.S. burn centers during the study period. Mean burn size was 14.8% (SD 11.2%) and mean age was 66.7 years (SD 9.3 years). Ninety-three patients had an inpatient rehabilitation stay before discharge (15.7%). Significant factors predictive of inpatient rehabilitation included a burn >20% TBSA, mechanical ventilation, older age, range of motion deficits at acute care discharge, and study site. These factors were included in the propensity model. Four hundred seventy-one patients (80%) were discharged to independent living status. By matched propensity analysis, older age was significantly associated with a higher likelihood of discharge to nonindependent living (P burn centers need to be elucidated to better understand discharge disposition status in older

  8. Lithium-manganese dioxide cells for implantable defibrillator devices - Discharge voltage models

    Energy Technology Data Exchange (ETDEWEB)

    Root, Michael J. [Cardiac Rhythm Management Research and Development, Boston Scientific Corp., 4100 Hamline Ave. N., St. Paul, MN 55112 (United States)

    2010-08-01

    The discharge potential behavior of lithium-manganese dioxide cells designed for implantable cardiac defibrillators was characterized as a function of extent of cell depletion for tests designed to discharge the cells for times between 1 and 7 years. The discharge potential curves may be separated into two segments from 0 {<=} x {<=} {proportional_to}0.51 and {proportional_to}0.51 {<=} x {<=} 1.00, where x is the dimensionless extent of discharge referenced to the rated cell capacity. The discharge potentials conform to Tafel kinetics in each segment. This behavior allows the discharge potential curves to be predicted for an arbitrary discharge load and long term discharge performance may be predicted from short term test results. The discharge potentials may subsequently be modeled by fitting the discharge curves to empirical functions like polynomials and Pade approximants. A function based on the Nernst equation that includes a term accounting for nonideal interactions between lithium ions and the cathode host material, such as the Redlich-Kister relationship, also may be used to predict discharge behavior. (author)

  9. Plasma processes in water under effect of short duration pulse discharges

    Science.gov (United States)

    Gurbanov, Elchin

    2013-09-01

    It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.

  10. Emission spectrum of an electric-discharge ClF laser

    International Nuclear Information System (INIS)

    Deryugin, A A; Razhev, A M; Kochetov, Igor' V

    1998-01-01

    Experiments revealed a complex structure of the emission spectrum of an electric-discharge ClF laser, corresponding to the D'-A' transitions with a maximum near 285 nm. The vibrational bands in the emission spectrum overlapped at the base in the range 282-286 nm because of a high pressure in the gaseous active medium. Theoretical calculations were made and an interpretation was provided of the vibrational structure of the emission spectrum of the ClF molecules. The emission spectrum of the electric-discharge ClF laser was shown to consist of the 0-4, 0-5, 0-6, 1-6, 1-7, and 2-8 bands of the D'-A' transition. A total efficiency of 0.1% was achieved for the first time for the ClF laser and lasing was observed in a gaseous He - F 2 -BCl 3 active medium. (lasers, active media)

  11. How long do centenarians survive? Life expectancy and maximum lifespan.

    Science.gov (United States)

    Modig, K; Andersson, T; Vaupel, J; Rau, R; Ahlbom, A

    2017-08-01

    The purpose of this study was to explore the pattern of mortality above the age of 100 years. In particular, we aimed to examine whether Scandinavian data support the theory that mortality reaches a plateau at particularly old ages. Whether the maximum length of life increases with time was also investigated. The analyses were based on individual level data on all Swedish and Danish centenarians born from 1870 to 1901; in total 3006 men and 10 963 women were included. Birth cohort-specific probabilities of dying were calculated. Exact ages were used for calculations of maximum length of life. Whether maximum age changed over time was analysed taking into account increases in cohort size. The results confirm that there has not been any improvement in mortality amongst centenarians in the past 30 years and that the current rise in life expectancy is driven by reductions in mortality below the age of 100 years. The death risks seem to reach a plateau of around 50% at the age 103 years for men and 107 years for women. Despite the rising life expectancy, the maximum age does not appear to increase, in particular after accounting for the increasing number of individuals of advanced age. Mortality amongst centenarians is not changing despite improvements at younger ages. An extension of the maximum lifespan and a sizeable extension of life expectancy both require reductions in mortality above the age of 100 years. © 2017 The Association for the Publication of the Journal of Internal Medicine.

  12. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    International Nuclear Information System (INIS)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen

    2013-01-01

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage

  13. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China)

    2013-06-15

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage.

  14. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  15. Experimental and theoretical investigation of Fe-catalysis phenomenon in hydrogen thermal desorption form hydrocarbon plasma-discharge films from T-10 tokamak

    International Nuclear Information System (INIS)

    Stankevich, V.G.; Svechnikov, N.Y.; Lebedev, A.M.; Menshikov, K.A.; Kolbasov, B.N.; Sukhanov, L.P.

    2017-01-01

    A comprehensive study of hydrocarbon films obtained in the plasma discharge of large fusion facilities will allow the minimization of parasitic capture. The investigation of the effect of Fe impurities on D 2 thermal desorption (TD) from homogeneous CD x films (x ∼ 0.5) formed in the D-plasma discharge of the T-10 tokamak were carried out. The experimental TD spectra of the films showed 2 groups of peaks at 650-850 K and 900-1000 K for 2 adsorption states. The main result of the iron catalysis effect consists in the shift of the high-temperature peak by -24 K and in the increase in the fraction of the weakly bonded adsorption states. To describe the effect of iron impurities on TD of hydrogen isotopes, a structural cluster model based on the interaction of the Fe + ion with the 1,3-C 6 H 8 molecule was proposed. The potential energy surfaces of chemical reactions with the H 2 elimination were calculated using ab initio methods of quantum chemistry. It was established that the activation barrier of hydrogen TD is reduced by about 1 eV due to the interaction of the Fe + ion with the π-subsystem of the 1,3-C 6 H 8 molecule leading to a redistribution of the double bonds along the carbon system

  16. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric fields

    International Nuclear Information System (INIS)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast intensified charge-coupled device (ICCD) imaging of the development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of the electric field in the discharge. The uniformity of the discharge images obtained with nanosecond exposure times was analysed using chi-square test. The results indicate that DBD uniformity strongly depends on the applied (global) electric field in the discharge gap, which is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is a transition from filamentary to uniform DBD mode that correlates to the corresponding decrease of the maximum local electric field in the discharge. (fast track communication)

  17. The Development and Evaluation of a Novel Instrument Assessing Residents' Discharge Summaries.

    Science.gov (United States)

    Hommos, Musab S; Kuperman, Ethan F; Kamath, Aparna; Kreiter, Clarence D

    2017-04-01

    To develop and determine the reliability of a novel measurement instrument assessing the quality of residents' discharge summaries. In 2014, the authors created a discharge summary evaluation instrument based on consensus recommendations from national regulatory bodies and input from primary care providers at their institution. After a brief pilot, they used the instrument to evaluate discharge summaries written by first-year internal medicine residents (n = 24) at a single U.S. teaching hospital during the 2013-2014 academic year. They conducted a generalizability study to determine the reliability of the instrument and a series of decision studies to determine the number of discharge summaries and raters needed to achieve a reliable evaluation score. The generalizability study demonstrated that 37% of the variance reflected residents' ability to generate an adequate discharge summary (true score variance). The decision studies estimated that the mean score from six discharge summary reviews completed by a unique rater for each review would yield a reliability coefficient of 0.75. Because of high interrater reliability, multiple raters per discharge summary would not significantly enhance the reliability of the mean rating. This evaluation instrument reliably measured residents' performance writing discharge summaries. A single rating of six discharge summaries can achieve a reliable mean evaluation score. Using this instrument is feasible even for programs with a limited number of inpatient encounters and a small pool of faculty preceptors.

  18. Maximum entropy methods

    International Nuclear Information System (INIS)

    Ponman, T.J.

    1984-01-01

    For some years now two different expressions have been in use for maximum entropy image restoration and there has been some controversy over which one is appropriate for a given problem. Here two further entropies are presented and it is argued that there is no single correct algorithm. The properties of the four different methods are compared using simple 1D simulations with a view to showing how they can be used together to gain as much information as possible about the original object. (orig.)

  19. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  20. Runaway electrons in toroidal discharges

    International Nuclear Information System (INIS)

    Knoepfel, H.

    1979-01-01

    Experimental and theoretical studies of runaway electrons in toroidal devices are reviewed here, with particular reference to tokamaks. The complex phenomenology of runaway effects, which have been the subject of research for the past twenty years, is organized within the framework of a number of physical models. The mechanisms and rates for runaway production are discussed first, followed by sections on runaway-driven kinetic relaxation processes and runaway orbit confinement. Next, the equilibrium and stability of runaway-dominated discharges are reviewed. Models for runaway production at early times in the discharge and the scaling of runaway phenomena to larger devices are also discussed. Finally, detection techniques and possible applications of runaways are mentioned. (author)

  1. Disruption characteristics in PDX with limiter and divertor discharges

    International Nuclear Information System (INIS)

    Couture, P.; McGuire, K.

    1986-09-01

    A comparison has been made between the characteristics of disruptions with limiter and divertor configurations in PDX. A large data base on disruptions has been collected over four years of machine operation, and a total of 15,000 discharges are contained in the data file. It was found that divertor discharges have less disruptions during ramp up and flattop of the plasma current. However, for divertor discharges a large number of fast, low current disruptions take place during the current ramp down. These disruptions are probably caused by the deformation of the plasma shape

  2. Transitions between corona, glow, and spark regimes of nanosecond repetitively pulsed discharges in air at atmospheric pressure

    Science.gov (United States)

    Pai, David Z.; Lacoste, Deanna A.; Laux, Christophe O.

    2010-05-01

    In atmospheric pressure air preheated from 300 to 1000 K, the nanosecond repetitively pulsed (NRP) method has been used to generate corona, glow, and spark discharges. Experiments have been performed to determine the parameter space (applied voltage, pulse repetition frequency, ambient gas temperature, and interelectrode gap distance) of each discharge regime. In particular, the experimental conditions necessary for the glow regime of NRP discharges have been determined, with the notable result that there exists a minimum and maximum gap distance for its existence at a given ambient gas temperature. The minimum gap distance increases with decreasing gas temperature, whereas the maximum does not vary appreciably. To explain the experimental results, an analytical model is developed to explain the corona-to-glow (C-G) and glow-to-spark (G-S) transitions. The C-G transition is analyzed in terms of the avalanche-to-streamer transition and the breakdown field during the conduction phase following the establishment of a conducting channel across the discharge gap. The G-S transition is determined by the thermal ionization instability, and we show analytically that this transition occurs at a certain reduced electric field for the NRP discharges studied here. This model shows that the electrode geometry plays an important role in the existence of the NRP glow regime at a given gas temperature. We derive a criterion for the existence of the NRP glow regime as a function of the ambient gas temperature, pulse repetition frequency, electrode radius of curvature, and interelectrode gap distance.

  3. Design, fabrication, and testing of a fast discharge homopolar machine (FDX)

    International Nuclear Information System (INIS)

    Gully, J.H.; Driga, M.D.; Grant, B.; Rylander, H.G.; Tolk, K.M.; Weldon, W.F.; Woodson, H.H.

    1977-01-01

    The Fast Discharge Experiment (FDX) is a 0.36 MJ, 200 V homopolar machine designed to discharge in one millisecond. All components, including dual brush actuation systems, a room-temperature 2 x 10 6 A-t pulsed copper coil, two aluminum rotors with copper slip rings, low inductance return conductors, coaxial transmission line, four fast closing (30 μsec), megamp switches, hydrostatic journal bearings, squeeze film thrust bearings and a fiberglass reinforced epoxy structure have been fabricated and assembled. The detail design of machine components is presented. Preliminary testing, including rotor spin-ups, brush actuation, switch making, and pulsed field coil tests have been concluded. A low speed, short-circuit discharge of FDX has recently been conducted. Experimental data from these tests are compared with theoretical predictions

  4. Leaf Dynamics of Panicum maximum under Future Climatic Changes.

    Science.gov (United States)

    Britto de Assis Prado, Carlos Henrique; Haik Guedes de Camargo-Bortolin, Lívia; Castro, Érique; Martinez, Carlos Alberto

    2016-01-01

    Panicum maximum Jacq. 'Mombaça' (C4) was grown in field conditions with sufficient water and nutrients to examine the effects of warming and elevated CO2 concentrations during the winter. Plants were exposed to either the ambient temperature and regular atmospheric CO2 (Control); elevated CO2 (600 ppm, eC); canopy warming (+2°C above regular canopy temperature, eT); or elevated CO2 and canopy warming (eC+eT). The temperatures and CO2 in the field were controlled by temperature free-air controlled enhancement (T-FACE) and mini free-air CO2 enrichment (miniFACE) facilities. The most green, expanding, and expanded leaves and the highest leaf appearance rate (LAR, leaves day(-1)) and leaf elongation rate (LER, cm day(-1)) were observed under eT. Leaf area and leaf biomass were higher in the eT and eC+eT treatments. The higher LER and LAR without significant differences in the number of senescent leaves could explain why tillers had higher foliage area and leaf biomass in the eT treatment. The eC treatment had the lowest LER and the fewest expanded and green leaves, similar to Control. The inhibitory effect of eC on foliage development in winter was indicated by the fewer green, expanded, and expanding leaves under eC+eT than eT. The stimulatory and inhibitory effects of the eT and eC treatments, respectively, on foliage raised and lowered, respectively, the foliar nitrogen concentration. The inhibition of foliage by eC was confirmed by the eC treatment having the lowest leaf/stem biomass ratio and by the change in leaf biomass-area relationships from linear or exponential growth to rectangular hyperbolic growth under eC. Besides, eC+eT had a synergist effect, speeding up leaf maturation. Therefore, with sufficient water and nutrients in winter, the inhibitory effect of elevated CO2 on foliage could be partially offset by elevated temperatures and relatively high P. maximum foliage production could be achieved under future climatic change.

  5. Self-discharge characteristics of lithium/sulfur batteries using TEGDME liquid electrolyte

    International Nuclear Information System (INIS)

    Ryu, H.S.; Ahn, H.J.; Kim, K.W.; Ahn, J.H.; Cho, K.K.; Nam, T.H.

    2006-01-01

    We investigated self-discharge characteristics of Li/S batteries using tetra ethylene glycol dimethylether (TEGDME) electrolyte. The open circuit voltages (OCV) and discharge curves were measured as a function of storage time. The self-discharge of the Li/S battery depended on current collectors. Li/TEGDME/S batteries with stainless steel (SUS) current collector showed the highest self-discharge rate of 59% per month. The self-discharge rate of Li/TEGDME/S battery using Al current collector is 34% during initial 80 days, but only 36% after 360 days storage. The discharge capacity decreases only 2% from 80 to 360 days. The self-discharge of Li/S battery using Al current collector is severe during initial 80 days, but is not an important factor after 80 days. Average self-discharge rate of Li/TEGDME/S battery using Al current collector is 3% per month for 1 year

  6. Collective doses from airborne discharges by the UK nuclear industry

    International Nuclear Information System (INIS)

    Kelly, G.N.

    1981-01-01

    Small quantities of radionuclides are discharged in airborne effluents during the normal operation of nuclear installations. The dispersion of these nuclides in the atmosphere and their subsequent transfer through various sectors of the environment leads to the irradiation of the population. The collective dose to the UK population from airborne discharges in one particular year, 1978, from UK nuclear installations is estimated. The discharges in that year are typical of those in the recent past. Consideration is given to the contribution made by each type of establishment (eg, nuclear power stations, reprocessing plants) and the nuclides which contribute significantly to the collective dose are identified. The distributions of the collective dose in time and among individuals in the exposed population are important features in determining the significance attached to it and both aspects are discussed. The collective dose can be used as a measure of the health detriment associated with the discharge practices considered and is one of several quantities to be taken into account in assessing them. The collective doses from airborne discharges are finally contrasted with those from other sources of exposure of the population. (author)

  7. Travelling-wave-sustained discharges

    International Nuclear Information System (INIS)

    Schlueter, Hans; Shivarova, Antonia

    2007-01-01

    This review is on discharges maintained by travelling waves: new plasma sources, discovered in 1974 and considered as a prototype of the gas discharges according to their definition as nonlinear systems which unify in a self-consistent manner plasmas and fields. In the presentation here of the fluid-plasma models of the diffusion-controlled regime of the travelling-wave-sustained discharges (TWSDs), the basic features of the discharge maintenance-the discharge self-consistency and the electron heating in the high-frequency field-are stressed. Operation of stationary and pulsed discharges, discharge maintenance without and in external magnetic fields as well as discharge production in different gases (argon, helium, helium-argon gas mixtures and hydrogen) are covered. Modulation instability of diffusion-controlled discharges and discharge filamentation at higher gas pressures are also included in the review. Experimental findings which motivate aspects of the reported modelling are pointed out

  8. Study of a new direct current atmospheric pressure glow discharge in helium

    Energy Technology Data Exchange (ETDEWEB)

    Gielniak, B. [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fiedler, T. [Johannes Gutenberg-University Mainz, Institute for Inorganic and Analytical Chemistry, Duesbergweg 10-14, 55128 Mainz (Germany); Broekaert, J.A.C., E-mail: jose.broekaert@chemie.uni-hamburg.de [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2011-01-15

    In this study a new DC-APGD operated in He was developed and characterized. The discharge is operated at 0.9 kV and about 25-35 mA and at a gas flow of 100 ml/min. The source was spectroscopically studied and parameters such as the rotational temperature (T{sub rot}), the excitation temperature (T{sub exc}), the ionization temperature (T{sub ion}) and the electron number density (n{sub e}) were determined. The current-voltage characteristic of the source was studied as well. At optimized conditions the discharge operates in the normal region of the current-voltage characteristic. Rotational and excitation temperatures determined with the use of OH band and Fe I lines as thermometric species were of the order of about 900-1200 and 4500-5500 K, respectively. This indicates that despite of the atmospheric pressure, the discharge is not in LTE. Spatially resolved temperature measurements were performed with axial as well as radial resolution and showed relatively flat profiles. Axially resolved emission intensity profiles for several species such as H, N{sub 2}, N{sub 2}{sup +}, OH, He and Hg were determined. It also was found that H{sub 2} introduced into the He by electrolysis of acid solutions such as in ECHG considerably increases the spectroscopically measured gas temperatures but decreases the analyte line intensities, as shown for Hg.

  9. Study of a new direct current atmospheric pressure glow discharge in helium

    International Nuclear Information System (INIS)

    Gielniak, B.; Fiedler, T.; Broekaert, J.A.C.

    2011-01-01

    In this study a new DC-APGD operated in He was developed and characterized. The discharge is operated at 0.9 kV and about 25-35 mA and at a gas flow of 100 ml/min. The source was spectroscopically studied and parameters such as the rotational temperature (T rot ), the excitation temperature (T exc ), the ionization temperature (T ion ) and the electron number density (n e ) were determined. The current-voltage characteristic of the source was studied as well. At optimized conditions the discharge operates in the normal region of the current-voltage characteristic. Rotational and excitation temperatures determined with the use of OH band and Fe I lines as thermometric species were of the order of about 900-1200 and 4500-5500 K, respectively. This indicates that despite of the atmospheric pressure, the discharge is not in LTE. Spatially resolved temperature measurements were performed with axial as well as radial resolution and showed relatively flat profiles. Axially resolved emission intensity profiles for several species such as H, N 2 , N 2 + , OH, He and Hg were determined. It also was found that H 2 introduced into the He by electrolysis of acid solutions such as in ECHG considerably increases the spectroscopically measured gas temperatures but decreases the analyte line intensities, as shown for Hg.

  10. Modelling groundwater discharge areas using only digital elevation models as input data

    International Nuclear Information System (INIS)

    Brydsten, Lars

    2006-10-01

    Advanced geohydrological models require data on topography, soil distribution in three dimensions, vegetation, land use, bedrock fracture zones. To model present geohydrological conditions, these factors can be gathered with different techniques. If a future geohydrological condition is modelled in an area with positive shore displacement (say 5,000 or 10,000 years), some of these factors can be difficult to measure. This could include the development of wetlands and the filling of lakes. If the goal of the model is to predict distribution of groundwater recharge and discharge areas in the landscape, the most important factor is topography. The question is how much can topography alone explain the distribution of geohydrological objects in the landscape. A simplified description of the distribution of geohydrological objects in the landscape is that groundwater recharge areas occur at local elevation curvatures and discharge occurs in lakes, brooks, and low situated slopes. Areas in-between these make up discharge areas during wet periods and recharge areas during dry periods. A model that could predict this pattern only using topography data needs to be able to predict high ridges and future lakes and brooks. This study uses GIS software with four different functions using digital elevation models as input data, geomorphometrical parameters to predict landscape ridges, basin fill for predicting lakes, flow accumulations for predicting future waterways, and topographical wetness indexes for dividing in-between areas based on degree of wetness. An area between the village of and Forsmarks' Nuclear Power Plant has been used to calibrate the model. The area is within the SKB 10-metre Elevation Model (DEM) and has a high-resolution orienteering map for wetlands. Wetlands are assumed to be groundwater discharge areas. Five hundred points were randomly distributed across the wetlands. These are potential discharge points. Model parameters were chosen with the

  11. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  12. Asthma - child - discharge

    Science.gov (United States)

    Pediatric asthma - discharge; Wheezing - discharge; Reactive airway disease - discharge ... Your child has asthma , which causes the airways of the lungs to swell and narrow. In the hospital, the doctors and nurses helped ...

  13. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  14. Pulsed wire discharge apparatus for mass production of copper nanopowders.

    Science.gov (United States)

    Suematsu, H; Nishimura, S; Murai, K; Hayashi, Y; Suzuki, T; Nakayama, T; Jiang, W; Yamazaki, A; Seki, K; Niihara, K

    2007-05-01

    A pulsed wire discharge (PWD) apparatus for the mass production of nanopowders has been developed. The apparatus has a continuous wire feeder, which is operated in synchronization with a discharging circuit. The apparatus is designed for operation at a maximum repetition rate of 1.4 Hz at a stored energy of 160 J. In the present study, Cu nanopowder was synthesized using the PWD apparatus and the performance of the apparatus was examined. Cu nanopowder of 2.0 g quantity was prepared in N(2) gas at 100 kPa for 90 s. The particle size distribution of the Cu nanopowder was analyzed by transmission electron microscopy and the mean surface diameter was determined to be 65 nm. The ratio of the production mass of the powder to input energy was 362 g/kW h.

  15. Weighted Regressions on Time, Discharge, and Season (WRTDS), with an application to Chesapeake Bay River inputs

    Science.gov (United States)

    Hirsch, Robert M.; Moyer, Douglas; Archfield, Stacey A.

    2010-01-01

    A new approach to the analysis of long-term surface water-quality data is proposed and implemented. The goal of this approach is to increase the amount of information that is extracted from the types of rich water-quality datasets that now exist. The method is formulated to allow for maximum flexibility in representations of the long-term trend, seasonal components, and discharge-related components of the behavior of the water-quality variable of interest. It is designed to provide internally consistent estimates of the actual history of concentrations and fluxes as well as histories that eliminate the influence of year-to-year variations in streamflow. The method employs the use of weighted regressions of concentrations on time, discharge, and season. Finally, the method is designed to be useful as a diagnostic tool regarding the kinds of changes that are taking place in the watershed related to point sources, groundwater sources, and surface-water nonpoint sources. The method is applied to datasets for the nine large tributaries of Chesapeake Bay from 1978 to 2008. The results show a wide range of patterns of change in total phosphorus and in dissolved nitrate plus nitrite. These results should prove useful in further examination of the causes of changes, or lack of changes, and may help inform decisions about future actions to reduce nutrient enrichment in the Chesapeake Bay and its watershed.

  16. Degradation of Verapamil hydrochloride in water by gliding arc discharge

    Czech Academy of Sciences Publication Activity Database

    Krishna, S.; Mašláni, Alan; Izdebski, T.; Horáková, M.; Klementová, Š.; Špatenka, P.

    2016-01-01

    Roč. 152, June (2016), s. 47-54 ISSN 0045-6535 Institutional support: RVO:61389021 Keywords : Gliding arc discharge * Emission spectroscopy * Pharmaceuticals * Half-life * Degradation mechanism Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 4.208, year: 2016 http://www.sciencedirect.com/science/article/pii/S0045653516302442

  17. Simulation of DIII-D Flat q Discharges

    International Nuclear Information System (INIS)

    Kessel, C.E.; Garofalo, A.; Terpstra, T.

    2004-01-01

    The Advanced Tokamak plasma configuration has significant potential for the economical production of fusion power. Research on various tokamak experiments are pursuing these plasmas to establish high β, high bootstrap current fraction, 100% noninductive current, and good energy confinement, in a quasi-stationary state. One candidate is the flat q discharge produced in DIII-D, where the safety factor varies from 2.0 on axis, to slightly below 2.0 at the minimum, and then rises to about 3.5 at the 95% surface. This plasma is prototypical of those studied for power plants in the ARIES tokamak studies. The plasma is produced by ramping up the plasma current and ramping down the toroidal field throughout the discharge. The plasma current reaches 1.65 MA, and the toroidal field goes from 2.25 to 1.6 T. The q min remains high and at large radius, ρ ∼ 0.6. The plasma establishes an internal transport barrier in the ion channel, and transitions to H-mode. The free-boundary Tokamak Simulation Code (TSC) is being used to model the discharge and project the impact of changes in the plasma current, toroidal field, and injected power programming

  18. Small surface wave discharge at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kiss' ovski, Zh; Kolev, M; Ivanov, A; Lishev, St; Koleva, I, E-mail: kissov@phys.uni-sofia.b [Faculty of Physics, Sofia University, BG-1164 Sofia (Bulgaria)

    2009-09-21

    A small surface wave driven source produces plasma at atmospheric pressure. Microwave power at frequency 2.45 GHz is coupled with the source and a discharge is ignited at power levels below 10 W. The coaxial exciter of the surface waves has a length of 10 mm because its dielectric is a high permittivity discharge tube. The plasma source operates as a plasma jet in the case of plasma columns longer than the tube length. The source maintains stable plasma columns over a wide range of neutral gas flow and applied power in continuous and pulse regimes. An additional advantage of this source is the discharge self-ignition. An electron temperature of T{sub e} {approx} 1.9 eV and a density of n{sub e} {approx} 3.9 x 10{sup 14} cm{sup -3} are estimated by the probe diagnostics method. The emission spectra in the wavelength range 200-1000 nm under different experimental conditions are analysed and they prove the applicability of the source for analytical spectroscopy. The dependences of column length, reflected power and plasma parameters on the gas flow and the input power are discussed. (fast track communication)

  19. Compact 4-kHz XeF-laser with multisectional discharge gap

    Science.gov (United States)

    Andramanov, A. V.; Kabaev, S. A.; Lazhintsev, Boris V.; Nor-Arevyan, Vladimir A.; Selemir, V. D.

    2005-03-01

    An electric-discharge XeF-laser with a pulse repetition rate up to 4 kHz was developed. The laser electrode unit was made on the basis of plate-like electrodes with inductive-capacity discharge stabilization. The narrow discharge width laser energy was 3 mJ by using He/Xe/NF3 and Ne/Xe/NF3 mixtures at the total pressure of 0.8 atm and 1.2 atm, respectively. The maximum laser efficiency was ~ 0.73% The gas flow was formed with the help of a diametrical fan rotated by the direct-current motor with 80 W power. The gas velocity of 20 m/s in the interelectrode gap was achieved. The laser pulse energy for a pulse repetition rate up to 3.5...4 kHz was virtually equal to the laser pulse energy in the infrequently-repeating-pulse regime. The average output power of 12 W at the pulse repetition rate of 4 kHz was achieved. The relative root-mean-square pulse-to-pulse variation of the output energy σ = 2.5% was reached.

  20. Short- and long-term plasma phenomena in a HiPIMS discharge

    International Nuclear Information System (INIS)

    Poolcharuansin, P; Bradley, J W

    2010-01-01

    evolution of the plasma potential shows that for a considerable fraction of the on-time the plasma potential remains negative (down to -12 V) only becoming positive after t ∼ 60 μs which corresponds to a time of maximum plasma density (typical values of 2 x 10 12 cm -3 ). The generation of super-thermal electrons in the initial phase of the discharge is argued through the development of a simple magnetized-electron bounce model of the expanding sheath.

  1. Size matters for violent discharge height and settling speed of Sphagnum spores: important attributes for dispersal potential.

    Science.gov (United States)

    Sundberg, Sebastian

    2010-02-01

    Initial release height and settling speed of diaspores are biologically controlled components which are key to modelling wind dispersal. Most Sphagnum (peat moss) species have explosive spore liberation. In this study, how capsule and spore sizes affect the height to which spores are propelled were measured, and how spore size and spore number of discharged particles relate to settling speed in the aspherical Sphagnum spores. Spore discharge and spore cloud development were filmed in a closed chamber (nine species). Measurements were taken from snapshots at three stages of cloud development. Settling speed of spores (14 species) and clusters were timed in a glass tube. The maximum discharge speed measured was 3.6 m s(-1). Spores reached a maximum height of 20 cm (average: 15 cm) above the capsule. The cloud dimensions at all stages were related positively to capsule size (R(2) = 0.58-0.65). Thus species with large shoots (because they have large capsules) have a dispersal advantage. Half of the spores were released as singles and the rest as clusters (usually two to four spores). Single spores settled at 0.84-1.86 cm s(-1), about 52 % slower than expected for spherical spores with the same diameters. Settling speed displayed a positive curvilinear relationship with spore size, close to predictions by Stokes' law for spherical spores with 68 % of the actual diameters. Light-coloured spores settled slower than dark spores. Settling speed of spore clusters agrees with earlier studies. Effective spore discharge and small, slowly settling spores appear particularly important for species in forested habitats. The spore discharge heights in Sphagnum are among the greatest for small, wind-dispersed propagules. The discharge heights and the slow settling of spores affect dispersal distances positively and may help to explain the wide distribution of most boreal Sphagnum species.

  2. Electron and Negative Ion Densities in C2F6 and CHF3 Containing Inductively Coupled Discharges

    International Nuclear Information System (INIS)

    HEBNER, GREGORY A.; MILLER, PAUL A.

    1999-01-01

    Electron and negative ion densities have been measured in inductively coupled discharges containing C 2 F 6 and CHF 3 . Line integrated electron density was determined using a microwave interferometer, negative ion densities were inferred using laser photodetachment spectroscopy, and electron temperature was determined using a Langmuir probe. For the range of induction powers, pressures and bias power investigated, the electron density peaked at 9 x 10 12 cm -2 (line-integrated) or approximately 9 x 10 11 cm -3 . The negative ion density peaked at approximately 1.3 x 10 11 cm -3 . A maximum in the negative ion density as a function of induction coil power was observed. The maximum is attributed to a power dependent change in the density of one or more of the potential negative ion precursor species since the electron temperature did not depend strongly on power. The variation of photodetachment with laser wavelength indicated that the dominant negative ion was F - . Measurement of the decay of the negative ion density in the afterglow of a pulse modulated discharge was used to determine the ion-ion recombination rate for CF 4 , C 2 F 6 and CHF 3 discharges

  3. Application to the system of insulated of diagnosis in high-voltage motors by partial discharge

    International Nuclear Information System (INIS)

    Mikami, M.

    2005-01-01

    In order to detect electric insulators degradation of high-voltage electric motors at an early stage, measurements of partial discharge of operating high-voltage electric motors (about 150 units) in the nuclear power plants were conducted from 2001 to 2004 by the use of on-line monitoring systems that could measure partial discharge of electric insulators. Influencing factors for measured values were identified from measured data and evaluation criteria of electric insulators integrity were established based on variations of partial discharge values. (T. Tanaka)

  4. Polyimide Nanocomposite Circuit Board Materials to Mitigate Internal Electrostatic Discharge, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Sub-topic T8.02, NASA has identified a need for improved circuit boards to mitigate the hazards of internal electrostatic discharge (IESD) on missions where high...

  5. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  6. Mixed memory, (non) Hurst effect, and maximum entropy of rainfall in the tropical Andes

    Science.gov (United States)

    Poveda, Germán

    2011-02-01

    Diverse linear and nonlinear statistical parameters of rainfall under aggregation in time and the kind of temporal memory are investigated. Data sets from the Andes of Colombia at different resolutions (15 min and 1-h), and record lengths (21 months and 8-40 years) are used. A mixture of two timescales is found in the autocorrelation and autoinformation functions, with short-term memory holding for time lags less than 15-30 min, and long-term memory onwards. Consistently, rainfall variance exhibits different temporal scaling regimes separated at 15-30 min and 24 h. Tests for the Hurst effect evidence the frailty of the R/ S approach in discerning the kind of memory in high resolution rainfall, whereas rigorous statistical tests for short-memory processes do reject the existence of the Hurst effect. Rainfall information entropy grows as a power law of aggregation time, S( T) ˜ Tβ with = 0.51, up to a timescale, TMaxEnt (70-202 h), at which entropy saturates, with β = 0 onwards. Maximum entropy is reached through a dynamic Generalized Pareto distribution, consistently with the maximum information-entropy principle for heavy-tailed random variables, and with its asymptotically infinitely divisible property. The dynamics towards the limit distribution is quantified. Tsallis q-entropies also exhibit power laws with T, such that Sq( T) ˜ Tβ( q) , with β( q) ⩽ 0 for q ⩽ 0, and β( q) ≃ 0.5 for q ⩾ 1. No clear patterns are found in the geographic distribution within and among the statistical parameters studied, confirming the strong variability of tropical Andean rainfall.

  7. 78 FR 49370 - Inflation Adjustment of Maximum Forfeiture Penalties

    Science.gov (United States)

    2013-08-14

    ... ``civil monetary penalties provided by law'' at least once every four years. DATES: Effective September 13... increases the maximum civil monetary forfeiture penalties available to the Commission under its rules... maximum civil penalties established in that section to account for inflation since the last adjustment to...

  8. Cytochrome P450 (CYP2D6) genotype is associated with elevated systolic blood pressure in preterm infants after discharge from the neonatal intensive care unit.

    Science.gov (United States)

    Dagle, John M; Fisher, Tyler J; Haynes, Susan E; Berends, Susan K; Brophy, Patrick D; Morriss, Frank H; Murray, Jeffrey C

    2011-07-01

    To determine genetic and clinical risk factors associated with elevated systolic blood pressure (ESBP) in preterm infants after discharge from the neonatal intensive care unit (NICU). A convenience cohort of infants born at 90th percentile for term infants). Genetic testing identified alleles associated with ESBP. Multivariate logistic regression analysis was performed for the outcome ESBP, with clinical characteristics and genotype as independent variables. Predictors of ESBP were cytochrome P450, family 2, subfamily D, polypeptide 6 (CYP2D6) (rs28360521) CC genotype (OR, 2.92; 95% CI, 1.48-5.79), adjusted for outpatient oxygen therapy (OR, 4.53; 95% CI, 2.23-8.81) and history of urinary tract infection (OR, 4.68; 95% CI, 1.47-14.86). Maximum SBP was modeled by multivariate linear regression analysis: maximum SBP=84.8 mm Hg + 6.8 mm Hg if cytochrome P450, family 2, subfamily D, polypeptide 6 (CYP2D6) CC genotype + 6.8 mm Hg if discharged on supplemental oxygen + 4.4 mm Hg if received inpatient glucocorticoids (P=.0002). ESBP is common in preterm infants with residual lung disease after discharge from the NICU. This study defines clinical factors associated with ESBP, identifies a candidate gene for further testing, and supports the recommendation to monitor blood pressure before age 3 years, as is suggested for term infants. Copyright © 2011 Mosby, Inc. All rights reserved.

  9. Loading pattern optimization with maximum utilization of discharging fuel employing adaptively constrained discontinuous penalty function

    International Nuclear Information System (INIS)

    Park, T. K.; Joo, H. G.; Kim, C. H.

    2010-01-01

    In order to find the most economical loading pattern (LP) considering multi-cycle fuel loading, multi-objective fuel LP optimization problems are examined by employing an adaptively constrained discontinuous penalty function (ACDPF) method. This is an improved method to simplify the complicated acceptance logic of the original DPF method in that the stochastic effects caused by the different random number sequence can be reduced. The effectiveness of the multi-objective simulated annealing (SA) algorithm employing ACDPF is examined for the reload core LP of Cycle 4 of Yonggwang Nuclear Unit 4. Several optimization runs are performed with different numbers of objectives consisting of cycle length and average burnup of fuels to be discharged or reloaded. The candidate LPs obtained from the multi-objective optimization runs turn out to be better than the reference LP in the aspects of cycle length and utilization of given fuels. It is note that the proposed ACDPF based MOSA algorithm can be a practical method to obtain an economical LP considering multi-cycle fuel loading. (authors)

  10. Computational Study of Anomalous Transport in High Beta DIII-D Discharges with ITBs

    Science.gov (United States)

    Pankin, Alexei; Garofalo, Andrea; Grierson, Brian; Kritz, Arnold; Rafiq, Tariq

    2015-11-01

    The advanced tokamak scenarios require a large bootstrap current fraction and high β. These large values are often outside the range that occurs in ``conventional'' tokamak discharges. The GLF23, TGLF, and MMM transport models have been previously validated for discharges with parameters associated with ``conventional'' tokamak discharges. It has been demonstrated that the TGLF model under-predicts anomalous transport in high β DIII-D discharges [A.M. Garofalo et al. 2015 TTF Workshop]. In this research, the validity of MMM7.1 model [T. Rafiq et al. Phys. Plasmas 20 032506 (2013)] is tested for high β DIII-D discharges with low and high torque. In addition, the sensitivity of the anomalous transport to β is examined. It is shown that the MMM7.1 model over-predicts the anomalous transport in the DIII-D discharge 154406. In particular, a significant level of anomalous transport is found just outside the internal transport barrier. Differences in the anomalous transport predicted using TGLF and MMM7.1 are reviewed. Mechanisms for quenching of anomalous transport in the ITB regions of high-beta discharges are investigated. This research is supported by US Department of Energy.

  11. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  12. Gas-discharge particle detector with ball-tipped anodes

    International Nuclear Information System (INIS)

    Travkin, V.I.; Khazins, D.M.

    1987-01-01

    A new gas-discharge particle detector, whose anode is a set of balls 2mm in diameter is investigated. The chamber is blowing down by the argon-methane-methylal gas mixture with the ratio 3:1:1. The detector operates in the self-quenching streamer mode, has high efficiency and a wide counting characteristic plateau. The maximum counting rate of particles at one ball is ∼ 2.5x10 4 s -1 . The ball-tipped anodes allow making reliable complex-shaped detectors. Two-coordinate detection of multiparticle events can be naturally organized in detectors like that

  13. Why do Electrons with "Anomalous Energies" appear in High-Pressure Gas Discharges?

    Science.gov (United States)

    Kozyrev, Andrey; Kozhevnikov, Vasily; Semeniuk, Natalia

    2018-01-01

    Experimental studies connected with runaway electron beams generation convincingly shows the existence of electrons with energies above the maximum voltage applied to the discharge gap. Such electrons are also known as electrons with "anomalous energies". We explain the presence of runaway electrons having so-called "anomalous energies" according to physical kinetics principles, namely, we describe the total ensemble of electrons with the distribution function. Its evolution obeys Boltzmann kinetic equation. The dynamics of self-consistent electromagnetic field is taken into the account by adding complete Maxwell's equation set to the resulting system of equations. The electrodynamic mechanism of the interaction of electrons with a travelling-wave electric field is analyzed in details. It is responsible for the appearance of electrons with high energies in real discharges.

  14. A multimodel approach to interannual and seasonal prediction of Danube discharge anomalies

    Science.gov (United States)

    Rimbu, Norel; Ionita, Monica; Patrut, Simona; Dima, Mihai

    2010-05-01

    Interannual and seasonal predictability of Danube river discharge is investigated using three model types: 1) time series models 2) linear regression models of discharge with large-scale climate mode indices and 3) models based on stable teleconnections. All models are calibrated using discharge and climatic data for the period 1901-1977 and validated for the period 1978-2008 . Various time series models, like autoregressive (AR), moving average (MA), autoregressive and moving average (ARMA) or singular spectrum analysis and autoregressive moving average (SSA+ARMA) models have been calibrated and their skills evaluated. The best results were obtained using SSA+ARMA models. SSA+ARMA models proved to have the highest forecast skill also for other European rivers (Gamiz-Fortis et al. 2008). Multiple linear regression models using large-scale climatic mode indices as predictors have a higher forecast skill than the time series models. The best predictors for Danube discharge are the North Atlantic Oscillation (NAO) and the East Atlantic/Western Russia patterns during winter and spring. Other patterns, like Polar/Eurasian or Tropical Northern Hemisphere (TNH) are good predictors for summer and autumn discharge. Based on stable teleconnection approach (Ionita et al. 2008) we construct prediction models through a combination of sea surface temperature (SST), temperature (T) and precipitation (PP) from the regions where discharge and SST, T and PP variations are stable correlated. Forecast skills of these models are higher than forecast skills of the time series and multiple regression models. The models calibrated and validated in our study can be used for operational prediction of interannual and seasonal Danube discharge anomalies. References Gamiz-Fortis, S., D. Pozo-Vazquez, R.M. Trigo, and Y. Castro-Diez, Quantifying the predictability of winter river flow in Iberia. Part I: intearannual predictability. J. Climate, 2484-2501, 2008. Gamiz-Fortis, S., D. Pozo

  15. The maximum and minimum values of the heat Q transmitted from metal to boiling water under atmospheric pressure

    International Nuclear Information System (INIS)

    Nukiyama, S.

    1991-01-01

    The quantity of heat transmitted from a metal surface to boiling water increases as the temperature difference ΔT is increased, but after the ΔT has reached a certain limit, quantity Q decreases with further increase in ΔT. This turning point is the maximum value of heat transmitted. The existence of this point was actually observed in the experiment. Under atmospheric pressure, ΔT corresponding to the maximum value of heat transfer for water at 100 degrees C falls between 20-40 degrees C, and Q is between 1,080,000 and 1,800,000 kcal/m 2 h (i.e. between 2,000 and 3,000 kg/m 2 h, if expressed in constant evaporation rate at 100 degrees C); this figure is larger than the maximum value of heat transfer as was previously considered. In this paper the minimum value of heat transfer was obtained, and in the Q-ΔT curve for the high temperature region, the burn-out effect is discussed

  16. In-hospital outcome of patients discharged from the ICU with ...

    African Journals Online (AJOL)

    Objective. To document the outcome of patients discharged from the intensive care unit (ICU) with tracheostomies. Design and setting. This was a retrospective study conducted in the ICU of Dr George Mukhari Hospital, Pretoria. Patients. All patients discharged from the ICU with tracheostomies over a period of 1 year from 1 ...

  17. Discharge estimation in arid areas with the help of optical satellite data

    Science.gov (United States)

    Mett, M.; Aufleger, M.

    2009-04-01

    The MENA region is facing severe water scarcity. Overexploitation of groundwater resources leads to an ongoing drawdown of the water tables, salinisation and desertification of vast areas. To make matters worse enormous birth-rates, economic growth and refugees from conflict areas let the need for water explode. In the context of climate change this situation will even worsen and armed conflicts are within the bounds of possibility. To ease water scarcity many innovative techniques like artificial groundwater recharge are being developed or already state of the art. But missing hydrological information (for instance discharge data) often prevents design and efficient operation of such measures. Especially in poor countries hydrological measuring devices like gage stations are often missing, in a bad status or professionals of the water sector are absent. This leads to the paradox situation that in many arid regions water resources are indeed available but they cannot be utilised because they are not known. Nowadays different approaches are being designed to obtain hydrological information from perennial river systems with the help of satellite techniques. Mostly they are based on hydraulic parameters like river dimensions, roughness and water levels which can be derived from satellite data. By using conventional flow formulas and additional field investigations the discharge can be estimated. Another methodology derived information about maximum flow depth and flow width from optical sensors of high resolution to calculate discharge of the rivers whilst the flood. Attempts to derive discharge information from structural components of the river and fluviomorphologic changes due to changing flow regimes are in the focus of recent research. One attempt used Synthetic Aperture Radar (SAR) data to estimate discharge in braided river systems. Other attempts used airborne SAR imagery to obtain information about sinuosity and total river width of perennial braided river

  18. Investigation of high-current low pressure quasistationary volume discharge in cross-field ExH

    International Nuclear Information System (INIS)

    Bashutin, O.A.; Vovchenko, E.D.; Kirnev, G.S.

    1995-01-01

    Different types of high current discharge permitted to create large volume of high density homogeneous plasma are widely used in modern technique. Such discharges are applied as plasma emitters of charged particles and also in various technologies for sputtering, implantation and etching of materials. The results of a plasma electron density dynamics investigation of low pressure quasistationary volume discharge in cross-field E x H is described in this paper. The discharge was created in a quadrupole magnetic system with special form electrodes and has following characteristics current up to 1,8 kA, voltage on the interval 80-120 V, existence time up to 1,5 ms. The discharge conserves diffusive character of plasma and cathode layer on all current range. On a first research stage plasma parameters of discharge were determined by means of Langmuir probe, that could been used in central discharge region only, where magnetic field was equal to zero. An obtained plasma density was reached 1,5*10 15 cm -3 with electron temperature T e =10 eV. The research of discharge plasma in regions with magnetic field had required to use interferometric measurement technique

  19. An unusual cause of vaginal discharge following gender reassignment.

    Science.gov (United States)

    Sukumaran, S; Moran, P A; Makar, A

    2009-02-01

    Neovaginal reconstruction is an important part of gender reassignment surgery. We report a case of stone formation at the apex of vaginal vault constructed with sigmoid colon segment. A 48-year-old woman presented with profuse vaginal discharge for 1 year. She had a history of gender reassignment surgery (male to female) in 1994, and the neovagina had been constructed with an isolated sigmoid colon. Vaginoscopy performed using a cystoscope revealed multiple calculi at the vaginal vault on the endoscopic gastrointestinal anastomosis staples that had been used to close the vault. Colon-vaginoplasty has the advantages of providing adequate lubrication, but excessive vaginal discharge could be a problem, as colon is a mucous membrane. Stone formation in the vaginal vault should be considered in cases of gender reassignment with persistent vaginal discharge. This case also highlights the use of cystoscope in visualising the upper vagina in difficult circumstances.

  20. An ensemble-based dynamic Bayesian averaging approach for discharge simulations using multiple global precipitation products and hydrological models

    Science.gov (United States)

    Qi, Wei; Liu, Junguo; Yang, Hong; Sweetapple, Chris

    2018-03-01

    Global precipitation products are very important datasets in flow simulations, especially in poorly gauged regions. Uncertainties resulting from precipitation products, hydrological models and their combinations vary with time and data magnitude, and undermine their application to flow simulations. However, previous studies have not quantified these uncertainties individually and explicitly. This study developed an ensemble-based dynamic Bayesian averaging approach (e-Bay) for deterministic discharge simulations using multiple global precipitation products and hydrological models. In this approach, the joint probability of precipitation products and hydrological models being correct is quantified based on uncertainties in maximum and mean estimation, posterior probability is quantified as functions of the magnitude and timing of discharges, and the law of total probability is implemented to calculate expected discharges. Six global fine-resolution precipitation products and two hydrological models of different complexities are included in an illustrative application. e-Bay can effectively quantify uncertainties and therefore generate better deterministic discharges than traditional approaches (weighted average methods with equal and varying weights and maximum likelihood approach). The mean Nash-Sutcliffe Efficiency values of e-Bay are up to 0.97 and 0.85 in training and validation periods respectively, which are at least 0.06 and 0.13 higher than traditional approaches. In addition, with increased training data, assessment criteria values of e-Bay show smaller fluctuations than traditional approaches and its performance becomes outstanding. The proposed e-Bay approach bridges the gap between global precipitation products and their pragmatic applications to discharge simulations, and is beneficial to water resources management in ungauged or poorly gauged regions across the world.

  1. ICRF power-deposition profiles, heating and confinement of monster sawtooth and peaked-density profile discharges in JET

    International Nuclear Information System (INIS)

    Bhatnagar, V.P.; Taroni, A.; Ellis, J.J.; Jacquinot, J.; Start, D.F.H.

    1989-01-01

    The ion cyclotron resonance heating of monster sawtooth (period greater than the energy confinement time) and pellet-fueled peaked-density profiles in limiter discharges of JET Tokamak are studied. The monster sawtooth is a characteristic JET regime which is related to fast ions generated during the minority ion heating. In the ICRF heating of peaked-density profile discharges, we find typically the T i0 is higher roughly by a factor of 2 and T e0 roughly by 35% at a fixed P TOT /n e0 when compared to non-peaked profile cases. Here, T e0 and T i0 are central electron and ion temperatures, respectively, n e0 is the central electron density and P TOT is the total input power. The ion heating is improved in the pellet case, in part, due to a higher collisionality between the background ions and the energetic minority, but more significantly by a reduction of local ion energy transport in the central region. The transport-code simulation of these discharges reveals that there is a reduction of both χ e and χ i in the central region of the plasma in the ICRF heated peaked-profile discharges where χ e and χ i are the electron and ion heat conductivities, respectively. The improvement of confinement is not explained quantitatively by any of the existing η i -driven turbulence theories as the n i parameter (η i = d ln T i /d ln n i where T i is the ion temperature and n i is the ion density), instead of dropping below the critical value, remains above it for most of the duration of the improved confinement phase. The physical mechanism(s) that plays a role in this improvement is not yet clear. (author)

  2. Discharge current characteristics as an 'electrical method' for glow discharge plasma diagnosis

    International Nuclear Information System (INIS)

    Toma, M.; Paraschivescu, Alina; Morminches, Anisoara

    2001-01-01

    In its simplest form, the glow discharge can be established by passing an electric current through gas between two electrodes. The gas and the electrodes are contained in an insulating envelope. In many technological applications, and not only, the plasma devices are often treated like a black box. There is a series of external parameters or control variables which can be adjusted to obtain a desired effect, namely, the operating voltage, gas pressure, gas nature, gas flow rate, magnetic field strength and magnetic field configuration, electric field geometry, interelectrode distance, and cathode characteristics. The discharge current can be controlled by each of the above control variables. The core idea of this work is the following: a lot of information about the phenomena from the discharge volume, at electrodes or at the discharge bounding wall surface, can be obtained knowing how the change of one of the control parameters influences the discharge current. The following regimes were analyzed: dark discharges (background ionization, saturation regime, Townsend regime, corona regime), glow discharge (the normal and abnormal discharge) and arc discharge (glow to arc transition, non-thermal arcs, thermal arcs). It was concluded that the nonlinearity in the shape of the discharge current characteristics as a function of an external control parameter, can be correlated with the elementary processes and the dynamics of different space charge structures generated in plasma devices. (authors)

  3. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Y; Yu, J; Xiao, Y [Thomas Jefferson University Hospital, Philadelphia, PA (United States)

    2015-06-15

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.

  4. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    International Nuclear Information System (INIS)

    Gong, Y; Yu, J; Xiao, Y

    2015-01-01

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant

  5. Heart attack - discharge

    Science.gov (United States)

    ... and lifestyle Cholesterol - drug treatment Controlling your high blood pressure Deep vein thrombosis - discharge Dietary fats explained Fast food tips Heart attack - discharge Heart attack - what to ask your doctor Heart bypass ... pacemaker - discharge High blood pressure - what to ask your doctor How to read ...

  6. Peak discharge of a Pleistocene lava-dam outburst flood in Grand Canyon, Arizona, USA

    Science.gov (United States)

    Fenton, Cassandra R.; Webb, Robert H.; Cerling, Thure E.

    2006-03-01

    The failure of a lava dam 165,000 yr ago produced the largest known flood on the Colorado River in Grand Canyon. The Hyaloclastite Dam was up to 366 m high, and geochemical evidence linked this structure to outburst-flood deposits that occurred for 32 km downstream. Using the Hyaloclastite outburst-flood deposits as paleostage indicators, we used dam-failure and unsteady flow modeling to estimate a peak discharge and flow hydrograph. Failure of the Hyaloclastite Dam released a maximum 11 × 10 9 m 3 of water in 31 h. Peak discharges, estimated from uncertainty in channel geometry, dam height, and hydraulic characteristics, ranged from 2.3 to 5.3 × 10 5 m 3 s -1 for the Hyaloclastite outburst flood. This discharge is an order of magnitude greater than the largest known discharge on the Colorado River (1.4 × 10 4 m 3 s -1) and the largest peak discharge resulting from failure of a constructed dam in the USA (6.5 × 10 4 m 3 s -1). Moreover, the Hyaloclastite outburst flood is the oldest documented Quaternary flood and one of the largest to have occurred in the continental USA. The peak discharge for this flood ranks in the top 30 floods (>10 5 m 3 s -1) known worldwide and in the top ten largest floods in North America.

  7. Estimating the maximum potential revenue for grid connected electricity storage :

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, Raymond Harry; Silva Monroy, Cesar Augusto.

    2012-12-01

    The valuation of an electricity storage device is based on the expected future cash flow generated by the device. Two potential sources of income for an electricity storage system are energy arbitrage and participation in the frequency regulation market. Energy arbitrage refers to purchasing (stor- ing) energy when electricity prices are low, and selling (discharging) energy when electricity prices are high. Frequency regulation is an ancillary service geared towards maintaining system frequency, and is typically procured by the independent system operator in some type of market. This paper outlines the calculations required to estimate the maximum potential revenue from participating in these two activities. First, a mathematical model is presented for the state of charge as a function of the storage device parameters and the quantities of electricity purchased/sold as well as the quantities o ered into the regulation market. Using this mathematical model, we present a linear programming optimization approach to calculating the maximum potential revenue from an elec- tricity storage device. The calculation of the maximum potential revenue is critical in developing an upper bound on the value of storage, as a benchmark for evaluating potential trading strate- gies, and a tool for capital nance risk assessment. Then, we use historical California Independent System Operator (CAISO) data from 2010-2011 to evaluate the maximum potential revenue from the Tehachapi wind energy storage project, an American Recovery and Reinvestment Act of 2009 (ARRA) energy storage demonstration project. We investigate the maximum potential revenue from two di erent scenarios: arbitrage only and arbitrage combined with the regulation market. Our analysis shows that participation in the regulation market produces four times the revenue compared to arbitrage in the CAISO market using 2010 and 2011 data. Then we evaluate several trading strategies to illustrate how they compare to the

  8. Energy scaling of focused discharges with enhanced reactivity

    International Nuclear Information System (INIS)

    Bortolotti, A.; Broglio, L.; Brzosko, J.S.; Dechiara, P.; Kilic, H.; Mezzetti, F.; Montanari, T.; Nardi, V.; Powell, C.; Woo, H.

    1993-01-01

    The neutron yield per pulse (Y n ) from D + D reactions, the thickness (δ) and speed (v s ) of the leading plasma current sheath in the electrode gap and the multiplicity (υ) of current sheaths in one discharge are monitored in two plasma focus machines operating at different levels of the capacitor bank energy 5 kJ ≤ W ≤ 10 kJ and 12 kJ ≤ W ≤ 30 kJ, respectively .The time spacing (Δt) between leading (CS 1 ) and trailing (CS 2 ) current sheath is also recorded up to a CS distance r = 1.7 cm from the center electrode (anode) axis. The scaling of Y n ∼ A W 2 is tested for PF-Mather-geometry machines with a field distortion element (FDE) inserted at the breech side of the electrode gap which increases Y n (i.e. the constant A) by a factor ≥ 5, above the Y n value of the same machines, operating under identical conditions, but without FDE, Similar scaling tests on Y n = Y n (W, δ, V s , υ, Δt) confirm that Δt is one of the controlling parameters with strong effects on Y n . Spectra and intensities of ion and ion cluster emission from the pinch are also routinely observed in each discharge, in order to determine the relative weight of each controlling parameter for a variety of PF applications

  9. Xenon capillary discharge as a source of soft X-ray

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.

    2002-01-01

    Roč. 52, supplement D (2002), s. 112-116 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/20th./. Prague, 10.06.2002-13.06.2002] Institutional research plan: CEZ:AV0Z2043910 Keywords : capillary discharge, soft X-ray Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.311, year: 2002

  10. Annual report on radioactive discharges from Winfrith and monitoring the environment 1990

    International Nuclear Information System (INIS)

    1991-06-01

    This annual report, the sixth of its type, aims to provide full information on discharges and environmental monitoring. The report is mainly graphical, comparing past and current levels with authorised limits, derived limits or the recommended limits of the International Commission on Radiological Protection (ICRP). All the data are presented at the end of the report in tabular form. Discharges from Winfrith are subject to Authorisations issued jointly by the Department of the Environment (DOE) and the Ministry of Agriculture, Fisheries and Food (MAFF). The numerical values of the Authorised Limits are based on past performance, future requirements and the application of Best Practicable Means (BPM). As a ''back stop'', discharges at the limits must not result in doses to the most potentially exposed part of the local population - the critical group - exceeding 0.5 mSv per year. The limit recommended by the International Commission on Radiological Protection (ICRP) for dose to a member of the general public is 1.0 mSv per year. In September 1990 Winfrith's Steam Generating Heavy Water Reactor (SGHWR) was shut down and a decision taken, later, that reactor operation would cease. The pattern of discharges thus changed in the last quarter of the year and discharges in future will be lower, and of a different pattern, than those of the past twenty years. The dose to the critical group, which is already less than 2% of the ICRP limit and less than 1% of the UK average natural background dose will drop further in future years. (Author)

  11. The maximum-entropy method in superspace

    Czech Academy of Sciences Publication Activity Database

    van Smaalen, S.; Palatinus, Lukáš; Schneider, M.

    2003-01-01

    Roč. 59, - (2003), s. 459-469 ISSN 0108-7673 Grant - others:DFG(DE) XX Institutional research plan: CEZ:AV0Z1010914 Keywords : maximum-entropy method, * aperiodic crystals * electron density Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.558, year: 2003

  12. Maximum physical capacity testing in cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Knutsen, L.; Quist, M; Midtgaard, J

    2006-01-01

    BACKGROUND: Over the past few years there has been a growing interest in the field of physical exercise in rehabilitation of cancer patients, leading to requirements for objective maximum physical capacity measurement (maximum oxygen uptake (VO(2max)) and one-repetition maximum (1RM)) to determin...... early in the treatment process. However, the patients were self-referred and thus highly motivated and as such are not necessarily representative of the whole population of cancer patients treated with chemotherapy....... in performing maximum physical capacity tests as these motivated them through self-perceived competitiveness and set a standard that served to encourage peak performance. CONCLUSION: The positive attitudes in this sample towards maximum physical capacity open the possibility of introducing physical testing...

  13. The comparative analysis of the current-meter method and the pressure-time method used for discharge measurements in the Kaplan turbine penstocks

    Science.gov (United States)

    Adamkowski, A.; Krzemianowski, Z.

    2012-11-01

    The paper presents experiences gathered during many years of utilizing the current-meter and pressure-time methods for flow rate measurements in many hydropower plants. The integration techniques used in these both methods are different from the recommendations contained in the relevant international standards, mainly from the graphical and arithmetical ones. The results of the comparative analysis of both methods applied at the same time during the hydraulic performance tests of two Kaplan turbines in one of the Polish hydropower plant are presented in the final part of the paper. In the case of the pressure-time method application, the concrete penstocks of the tested turbines required installing a special measuring instrumentation inside the penstock. The comparison has shown a satisfactory agreement between the results of discharge measurements executed using the both considered methods. Maximum differences between the discharge values have not exceeded 1.0 % and the average differences have not been greater than 0.5 %.

  14. The comparative analysis of the current-meter method and the pressure-time method used for discharge measurements in the Kaplan turbine penstocks

    International Nuclear Information System (INIS)

    Adamkowski, A; Krzemianowski, Z

    2012-01-01

    The paper presents experiences gathered during many years of utilizing the current-meter and pressure-time methods for flow rate measurements in many hydropower plants. The integration techniques used in these both methods are different from the recommendations contained in the relevant international standards, mainly from the graphical and arithmetical ones. The results of the comparative analysis of both methods applied at the same time during the hydraulic performance tests of two Kaplan turbines in one of the Polish hydropower plant are presented in the final part of the paper. In the case of the pressure-time method application, the concrete penstocks of the tested turbines required installing a special measuring instrumentation inside the penstock. The comparison has shown a satisfactory agreement between the results of discharge measurements executed using the both considered methods. Maximum differences between the discharge values have not exceeded 1.0 % and the average differences have not been greater than 0.5 %.

  15. Environmental contaminants in oil field produced waters discharged into wetlands

    International Nuclear Information System (INIS)

    Ramirez, P. Jr.

    1994-01-01

    The 866-acre Loch Katrine wetland complex in Park County, Wyoming provides habitat for many species of aquatic birds. The complex is sustained primarily by oil field produced waters. This study was designed to determine if constituents in oil field produced waters discharged into Custer Lake and to Loch Katrine pose a risk to aquatic birds inhabiting the wetlands. Trace elements, hydrocarbons and radium-226 concentrations were analyzed in water, sediment and biota collected from the complex during 1992. Arsenic, boron, radium-226 and zinc were elevated in some matrices. The presence of radium-226 in aquatic vegetation suggests that this radionuclide is available to aquatic birds. Oil and grease concentrations in water from the produced water discharge exceeded the maximum 10 mg/l permitted by the WDEQ (1990). Total aliphatic and aromatic hydrocarbon concentrations in sediments were highest at the produced water discharge, 6.376 μg/g, followed by Custer Lake, 1.104 μg/g. The higher levels of hydrocarbons found at Custer Lake, compared to Loch Katrine, may be explained by Custer Lake's closer proximity to the discharge. Benzo(a)pyrene was not detected in bile from gadwalls collected at Loch Katrine but was detected in bile from northern shovelers collected at Custer Lake. Benzo(a)pyrene concentrations in northern shoveler bile ranged from 500 to 960 ng/g (ppb) wet weight. The presence of benzo(a)pyrene in the shovelers indicates exposure to petroleum hydrocarbons

  16. Pump effect of a capillary discharge in electrically conductive liquids

    Czech Academy of Sciences Publication Activity Database

    De Baerdemaeker, F.; Šimek, Milan; Leys, C.; Verstraete, W.

    2007-01-01

    Roč. 27, č. 4 (2007), s. 473-485 ISSN 0272-4324 R&D Projects: GA AV ČR IAA1043403 Institutional research plan: CEZ:AV0Z20430508 Keywords : water * conductive * capillary * AC discharge * pump Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.747, year: 2007 http://www.springerlink.com/content/w802073563282272/fulltext.pdf

  17. Ozone formation by gaseous corona discharge generated above aqueous solution

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Petr; Člupek, Martin; Babický, Václav; Šunka, Pavel

    2004-01-01

    Roč. 54, suppl. C (2004), C909-C913 ISSN 0011-4626. [Symposium on Plasma Physics and Technology /21st/. Praha, 14.06.2004-17.06.2004] R&D Projects: GA ČR GA202/02/1026 Keywords : corona discharg, ozone Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.292, year: 2004

  18. The study of discharge cleaning in the JFT-2 tokamak with surface observation by AES

    International Nuclear Information System (INIS)

    Gomay, Yoshio; Tazima, Teruhiko; Fujisawa, Noboru; Suzuki, Norio; Konoshima, Shigeru

    1976-07-01

    Noticeable correlations were observed between the changes of discharge characteristics, wall conditions and typical mass peaks with discharge cleaning in the JFT-2 tokamak. Atomic composition of the vacuum wall surface observed by AES becomes constant with continuing discharge cleaning in the level except hydrogen and helium: 30-50% C, 20-30% Mo, 15-30% stainless steel elements and 10-15% O. The stable reproducible plasma with Z sub(eff)=4.5 was obtained in this wall condition. The limiter and vacuum wall materials (Mo and 304 stainless steel, respectively), carbon and oxygen were observed depositing on the wall in the thickness of about 300 A at the minimum inner radius of the vacuum chamber and 40 A nearly at the maximum after 2900 cleaning pulses. The mechanism determining the wall condition is also discussed. (auth.)

  19. Radioactive liquid waste discharged from Nuclear Electric licensed sites during 1991

    International Nuclear Information System (INIS)

    Austin, L.S.; Odell, K.J.

    1993-03-01

    This report presents the detailed isotopic composition of radioactive liquid waste discharged from Nuclear Electric licensed sites in 1991. Liquid discharges from those Magnox stations using pond storage of irradiated fuel contained low levels of activation and fission products, while those from Wylfa and the AGR stations contained lower levels of activation products with only traces of fission products. Discharges were similar to those observed in previous years, with any changes concordant with changes in stations' generation performance. (author)

  20. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    International Nuclear Information System (INIS)

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  1. The effects of pre-natal-, early-life- and indirectly-initiated exposures to maximum adversities on the course of schizophrenia.

    Science.gov (United States)

    Levine, Stephen Z; Levav, Itzhak; Yoffe, Rinat; Pugachova, Inna

    2014-09-01

    The effects of pre-natal-, early-life- and indirectly-initiated exposures to protracted maximum adversity on the course of schizophrenia are unknown. To compare the aforementioned Holocaust directly exposed subgroups with an indirectly exposed subgroup on the course of schizophrenia. The study population were: Israeli Jews in-uterus or born in Nazi-occupied or dominated European nations by the end of the persecution of the Jews, who were alive in 1950, and who had a last discharge diagnosis of schizophrenia in the Israel National Psychiatric Case Registry by 2013 (N=4933). The population was disaggregated into subgroups who (1) migrated after WWII and who had (1a) pre-natal (n=584, 11.8%) and (1b) early-life (n=3709, 75.2%) initiated exposures to the maximum adversities of the Holocaust, and (2) indirectly exposed individuals to the Holocaust who migrated before the Nazi-era persecution begun (n=640, 13%). Recurrent event survival analyses were computed to examine the psychiatric re-hospitalization risk of the study subgroups, unadjusted and adjusted for age of onset of the disorder and sex. The pre-natal initiated exposure subgroup had a significantly (pPoland-born individuals, the years 1922 and 1935; and followed at least 10 years and to the year 2000. Pre-natal initiated exposure to the maximal adversity of the holocaust constitutes a consistent risk factor for a worse course of schizophrenia, a possible byproduct of neurodevelopment disruptions induced by maternal stress and/or famine and/or infections. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. 46 CFR 34.15-30 - Alarms-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... Systems, Details § 34.15-30 Alarms—T/ALL. (a) Spaces required to have a delayed discharge by § 34.15-10(f... board while the vessel is being navigated, other than paint and lamp lockers and similar small spaces... to sound during the 20-second delay period prior to the discharge of carbon dioxide into the space...

  3. Essential Oil of Amomum maximum Roxb. and Its Bioactivities against Two Stored-Product Insects.

    Science.gov (United States)

    Guo, Shan-Shan; You, Chun-Xue; Liang, Jun-Yu; Zhang, Wen-Juan; Yang, Kai; Geng, Zhu-Feng; Wang, Cheng-Fang; Du, Shu-Shan; Lei, Ning

    2015-01-01

    Amomum maximum Roxb. is a perennial herb distributed in South China and Southeast Asia. The objective of this work was to analyze the chemical constituents and assess insecticidal and repellent activities of the essential oil from Amomum maximum fruits against Tribolium castaneum (Herbst) and Liposcelis bostrychophila (Badonnel). The essential oil was obtained by hydrodistillation and analyzed by gas chromatography-flame ionization detector and gas chromatography-mass spectrometry. The main components of the essential oil were identified to be β-pinene (23.39%), β-caryophyllene (16.43%), α-pinene (7.55%), sylvestrene (6.61%) and ç-cadinene (4.19%). It was found that the essential oil of A. maximum fruits possessed contact and fumigant toxicities against T. castaneum adults (LD50 = 29.57 μg/adult and LC(50) = 23.09 mg/L air, respectively) and showed contact toxicity against L. bostrychophila (LD(50) = 67.46 μg/cm(2)). Repellency of the crude oil was also evaluated. After 2 h treatment, the essential oil possessed 100% repellency at 78.63 nL/cm(2) against T. castaneum and 84% repellency at 63.17 nL/cm(2) against L. bostrychophila. The results indicated that the essential oil of A. maximum fruits had the potential to be developed as a natural insecticide and repellent for control of T. castaneum and L. bostrychophila.

  4. Determination of discharge authorizations for French basic nuclear installations 58 and public information

    International Nuclear Information System (INIS)

    Tabard, Laurence; Conte, Dorothee

    2013-01-01

    The determination of discharge authorized limits for a French nuclear site is initiated by the request of the operator, based on the maximum nuclear and chemical inventory that could be released during normal operating conditions, accompanied with justifications. Request and justifications are analyzed and discussed by the ASN and the IRSN, taking into account nuclear and chemical inventories expected inside BNI, current regulations (BNI specific regulation, environment code, public health code), operating feedback (release feedback for an operating BNI, feedback coming from other nuclear sites or installations, etc.) and best available technologies that can be used to treat liquid or gaseous waste before release. After taking into account potential suggestions coming from public information or public enquiry concerning the operator request, the discharge authorized limits are settled down in specific ASN prescriptions that have to be ratified by the State secretaries in charge of nuclear safety. The whole process runs through 2 or 3 years to be achieved. Communication has revealed to be quite an uneasy task, even for administrative procedures. This aspect is mostly tested while communicating about events. Consequences of this communication can hardly be foreseen because of multiple external parameters like: news on the front pages at the same moment; historic communication difficulties still in the public mind; technical vocabulary not easily understood; public fear of things being hidden; power of ecologist or non-governmental associations. (authors)

  5. A practical assessment of aquifer discharge for regional groundwater demand by characterizing leaky confined aquifer overlain on a Mesozoic granitic gneiss basement

    Science.gov (United States)

    Shih, David Ching-Fang

    2018-04-01

    Due to increasing population worldwide, there is an urgent need to manage these important but diminishing groundwater resources efficiently to ensure their continued availability. The major innovative design of this study is to provide a practical assessment process for groundwater discharge under a regional demand by characterizing the nature of leaky confined aquifers overlain on a Mesozoic granitic gneiss basement which involves the important groundwater system in the Kinmen region (Taiwan, ROC) and the assessment of adoptable groundwater discharge in aquifer is needed. The storage coefficient presents an order of one in a thousand and hydraulic conductivity is approximately at the order of 1-8 m/d and 0.4-0.9 m/d for aquifer and aquitard respectively. Groundwater discharge and admissible number of pumping well is suggested considering scheduled maximum groundwater volume and head decline change for eastern and western studied area respectively. The safety subjected to the conservative issue is then addressed by the use of scheduled maximum groundwater volume. It reveals that the safety can be ensured using the indicator as scheduled maximum groundwater volume with predefined scenarios. The result can be utilized practically for developing management strategy of groundwater resources due to the applicability and novel of method.

  6. T-12 divertor experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bortnikov, A V; Brevnov, N N; Gerasimov, S N; Zhukovskii, V G; Kuznetsov, N V; Naftulin, S M; Pergament, V I; Khimchenko, L N [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii

    1981-01-01

    In designing tokamak devices and reactors, in the last few years, the use of elongated-cross-section plasma discharges has been proposed to improve the economic and physical parameters. Application of a quadrupole poloidal magnetic field necessary for sustaining the elongated discharge cross-section serves, in this case, to create the magnetic configuration of an axisymmetric poloidal divertor. To-day, the creation of such a combination, including an elongated plasma cross-section and a divertor and using the outer poloidal magnetic field coils, seems to be the most reasonable approach, from the point of view of design and technology. Such a divertor was produced and studied at the T-12 tokamak. A stable equilibrium configuration of a finger-ring tokamak with a divertor has been produced by superposing the magnetic fields of the plasma current, the external quadrupole coils and the copper shell currents; the reactor blanket can fulfil the function of the latter. It is shown that both a symmetric magnetic configuration with two divertors and a droplet configuration with a single divertor may be realized by controlling the plasma column position with respect to the equatorial plane. The stability of the plasma column against vertical displacement depends on this position and the distance between the separatrix points. Vertical instability stabilization has been observed. The divertor layer efficiently screens the plasma from the impurity influx from the wall and unloads the wall from particle and energy fluxes. The results obtained from the tokamak T-12 experiment have demonstrated the capability of a system with outer poloidal field coils and a copper shell providing an elongated-cross-section plasma column with poloidal divertors.

  7. Catastrophic Disruption Threshold and Maximum Deflection from Kinetic Impact

    Science.gov (United States)

    Cheng, A. F.

    2017-12-01

    The use of a kinetic impactor to deflect an asteroid on a collision course with Earth was described in the NASA Near-Earth Object Survey and Deflection Analysis of Alternatives (2007) as the most mature approach for asteroid deflection and mitigation. The NASA DART mission will demonstrate asteroid deflection by kinetic impact at the Potentially Hazardous Asteroid 65803 Didymos in October, 2022. The kinetic impactor approach is considered to be applicable with warning times of 10 years or more and with hazardous asteroid diameters of 400 m or less. In principle, a larger kinetic impactor bringing greater kinetic energy could cause a larger deflection, but input of excessive kinetic energy will cause catastrophic disruption of the target, leaving possibly large fragments still on collision course with Earth. Thus the catastrophic disruption threshold limits the maximum deflection from a kinetic impactor. An often-cited rule of thumb states that the maximum deflection is 0.1 times the escape velocity before the target will be disrupted. It turns out this rule of thumb does not work well. A comparison to numerical simulation results shows that a similar rule applies in the gravity limit, for large targets more than 300 m, where the maximum deflection is roughly the escape velocity at momentum enhancement factor β=2. In the gravity limit, the rule of thumb corresponds to pure momentum coupling (μ=1/3), but simulations find a slightly different scaling μ=0.43. In the smaller target size range that kinetic impactors would apply to, the catastrophic disruption limit is strength-controlled. A DART-like impactor won't disrupt any target asteroid down to significantly smaller size than the 50 m below which a hazardous object would not penetrate the atmosphere in any case unless it is unusually strong.

  8. CO-AXIAL DISCHARGES

    Science.gov (United States)

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  9. California study compares natural/drilling discharge contaminants offshore

    International Nuclear Information System (INIS)

    Steinhauer, W.G.; Imamura, E.; Barminski, J.R.; Neff, J.M.

    1992-01-01

    An analysis of drilling fluid and this paper reports that cuttings discharges in the southern Santa Maria basin offshore California indicates that the amount of metal and hydrocarbon contaminants from drilling operations is small relative to that from natural sources. The metal and hydrocarbon discharges were calculated for only one of the three platforms discharging between 1986 and 1989 in the Point Arguello field. However, assuming concentrations are similar on each platform, the combined input of metals and hydrocarbons over the 3-year period was still low (except for barium and lead) compared to the average annual flux from natural sources. The MMS is monitoring the Santa Maria basin to understand possible long-term environmental effects of oil and gas development (California Monitoring Program, Phase II; and Effects of OCS Production Platforms on Rocky Reef Fishes and Fisheries). A site-specific study area was established to determine effects of drilling-related discharges at Chevron U.S.S. Inc.'s platform Hidalgo in the Point Arguello field. Part of the study included review of discharge records for platforms Hidalgo, Hermosa (Chevron), and Harvest (Texaco Exploration and Production Inc.)

  10. The association between guideline-based treatment instructions at the point of discharge and lower 1-year mortality in Medicare patients after acute myocardial infarction: the American College of Cardiology's Guidelines Applied in Practice (GAP) initiative in Michigan.

    Science.gov (United States)

    Rogers, Adam M; Ramanath, Vijay S; Grzybowski, Mary; Riba, Arthur L; Jani, Sandeep M; Mehta, Rajendra; De Franco, Anthony C; Parrish, Robert; Skorcz, Stephen; Baker, Patricia L; Faul, Jessica; Chen, Benrong; Roychoudhury, Canopy; Elma, Mary Anne C; Mitchell, Kristi R; Froehlich, James B; Montoye, Cecelia; Eagle, Kim A

    2007-09-01

    The American College of Cardiology's Guidelines Applied in Practice (GAP) initiative for acute myocardial infarction (AMI) has been shown to increase the use of guideline-based therapies and improve outcomes in patients with AMI. It is unknown whether hospitals that are more successful in using the standard discharge contract--a key component of GAP that emphasizes guideline-based medications, lifestyle modification, and follow-up planning--experience a proportionally greater improvement in patient outcomes. Medicare patients treated for AMI in all 33 participating GAP hospitals in Michigan were enrolled. We aggregated the hospitals into 3 tertiles based on the rates of discharge contract use: 0% to 8.4% (tertile 1), >8.4% to 38.0% (tertile 2), and >38.0% to 61.1% (tertile 3). We analyzed 1-year follow-up mortality both pre- and post-GAP and compared the mortality decline post-GAP with discharge contract use according to tertile. There were 1368 patients in the baseline (pre-GAP) cohort and 1489 patients in the post-GAP cohort. After GAP implementation, mortality at 1 year decreased by 1.2% (P = .71), 1.2% (P = .68), and 6.0% (P = .03) for tertiles 1, 2, and 3, respectively. After multivariate adjustment, discharge contract use was significantly associated with decreased 1-year mortality in tertile 2 (odds ratio 0.43, 95% CI 0.22-0.84) and tertile 3 (odds ratio 0.45, 95% CI 0.27-0.75). Increased hospital utilization of the standard discharge contract as part of the GAP program is associated with decreased 1-year mortality in Medicare patient populations with AMI. Hospital efforts to promote adherence to guideline-based care tools such as the discharge contract used in GAP may result in mortality reductions for their patient populations at 1 year.

  11. Electrical discharge light sources: a challenge for the future

    International Nuclear Information System (INIS)

    Zissis, G.

    2001-01-01

    The first electric powder lamp operated that 150 years ago, since then the evolution of light sources is astonishing. Today, more than 10 % of the global electric power produced worldwide serve fore light production from several billions lamps. Since last three decades incandescent lamps are gradually replaced by more energy efficient discharge lamps. In parallel, new generation of light emitting diodes, producing bright colours (including white) with luminous efficacy challenging even discharge lamps, appeared in past years. The objective of this paper is to focus on the state of art in the domain of light sources and discuss the challenges for the near future. (author)

  12. Characterization of the Novillo Tokamak in main discharge regime; Caracterizacion del Tokamak Novillo en regimen de descarga principal

    Energy Technology Data Exchange (ETDEWEB)

    Lopez C, R.; Melendez L, L.; Chavez A, E.; Colunga S, S.; Valencia A, R.; Gaytan G, E

    1992-07-15

    The analytical procedure to carry out the establishment of the discharge in a Tokamak including: a) Ionization, b) Diffusion losses, recombination, union, drift speed, spurious fields, and c) Electric field is presented. In an experimental way a procedure settles down by means of which it is characterized the plasma, specially a new characteristic discharge parameter is settled down and it is the plasma current by the duration of the (I{sub p}t) discharge. (Author)

  13. Assessment of the Relationship between Andean Ice Core Precipitation Indicators and Amazon River Discharge

    Science.gov (United States)

    Johnson, N.; Alsdorf, D.; Thompson, L.; Mosley-Thompson, E.; Melack, J.

    2006-12-01

    Prior to the last 100 years, there is a significant lack of hydrologic knowledge for the Amazon Basin. A 100- year record of discharge from the city of Manaus, located at the confluence of the Solimoes and Negro rivers, is the most complete record for the basin. Inundated wetlands play a key role in carbon out-gassing to the atmosphere whereas discharge from the Amazon River contributes about 20% of the total freshwater flux delivered to the world's oceans. As discharge (Q) and inundation are directly related to precipitation, we are developing a method to extend our understanding of Q and inundation into the 19^{th} century. Using proxy data preserved in Andean glaciers and ice caps and recovered from ice cores, annually resolved histories of δ^{18)O and mass accumulation are available. The latter is a proxy for local precipitation amount whereas δ18O is influenced by continental scale processes (i.e., evaporation, convection) as well as by temperature and hence, by varying climate regimes. We have correlated the accumulation and δ18O records from Core 1 drilled on the Quelccaya ice-cap in the southern Andes of Peru with the Manaus discharge data. As ice core annual layers correspond to the thermal year (in Peru, July to June of the following year) and the discharge records are kept daily (January to December), we averaged 365 days of Q data seeking the optimal correlation for each start and end date. The best statistical relationship between δ18O and Q (r = -0.41, p = < 0.001) is attained when Q is averaged from March 16 to March 15 of the following year. We also correlated 23 years of ENSO events, which are linked to both Amazon River discharge and ice core δ18O (r = -0.60, p = < 0.001). These linear relationships are used to create Amazon discharge for the 20^{th} century and to extrapolate Q into the 19^{th} century. Previously developed relationships between Q and mainstem inundated area are then used to estimate inundated area along the main Amazon

  14. The creation of hypersonic flows by a powerful impulse capillary discharge

    Science.gov (United States)

    Pashchina, A. S.; Karmatsky, R. E.; Klimov, A. I.

    2017-11-01

    The possibility of using a powerful pulsed capillary discharge to produce quasi-stationary highspeed plasma flows with characteristic Mach numbers M = 3-10 and temperatures T = 3000-6000 K has been experimentally substantiated. In a rarefied gas atmosphere ( p ∞ condensed particles in a carbon-containing plasma.

  15. 2D simulation of active species and ozone production in a multi-tip DC air corona discharge

    Science.gov (United States)

    Meziane, M.; Eichwald, O.; Sarrette, J. P.; Ducasse, O.; Yousfi, M.

    2011-11-01

    The present paper shows for the first time in the literature a complete 2D simulation of the ozone production in a DC positive multi-tip to plane corona discharge reactor crossed by a dry air flow at atmospheric pressure. The simulation is undertaken until 1 ms and involves tens of successive discharge and post-discharge phases. The air flow is stressed by several monofilament corona discharges generated by a maximum of four anodic tips distributed along the reactor. The nonstationary hydrodynamics model for reactive gas mixture is solved using the commercial FLUENT software. During each discharge phase, thermal and vibrational energies as well as densities of radical and metastable excited species are locally injected as source terms in the gas medium surrounding each tip. The chosen chemical model involves 10 neutral species reacting following 24 reactions. The obtained results allow us to follow the cartography of the temperature and the ozone production inside the corona reactor as a function of the number of high voltage anodic tips.

  16. Stability of negative central magnetic shear discharges in the DIII-D tokamak

    International Nuclear Information System (INIS)

    Strait, E.J.; Chu, M.S.; Ferron, J.R.

    1996-12-01

    Discharges with negative central magnetic shear (NCS) hold the promise of enhanced fusion performance in advanced tokamaks. However, stability to long wavelength magnetohydrodynamic modes is needed to take advantage of the improved confinement found in NCS discharges. The stability limits seen in DIII-D experiments depend on the pressure and current density profiles and are in good agreement with stability calculations. Discharges with a strongly peaked pressure profile reach a disruptive limit at low beta, β N = β (I/aB) -1 ≤ 2.5 (% m T/MA), caused by an n = 1 ideal internal kink mode or a global resistive instability close to the ideal stability limit. Discharges with a broad pressure profile reach a soft beta limit at significantly higher beta, β N = 4 to 5, usually caused by instabilities with n > 1 and usually driven near the edge of the plasma. With broad pressure profiles, the experimental stability limit is independent of the magnitude of negative shear but improves with the internal inductance, corresponding to lower current density near the edge of the plasma. Understanding of the stability limits in NCS discharges has led to record DIII-D fusion performance in discharges with a broad pressure profile and low edge current density

  17. Spectrum of vaginal discharge in a tertiary care setting.

    Science.gov (United States)

    Sivaranjini, R; Jaisankar, Tj; Thappa, Devinder Mohan; Kumari, Rashmi; Chandrasekhar, Laxmisha; Malathi, M; Parija, Sc; Habeebullah, S

    2013-07-01

    Vaginal discharge is one of the common reasons for gynecological consultation. Many of the causes of vaginitis have a disturbed vaginal microbial ecosystem associated with them. Effective treatment of vaginal discharge requires that the etiologic diagnosis be established and identifying the same offers a precious input to syndromic management and provides an additional strategy for human immunodeficiency virus prevention. The present study was thus carried out to determine the various causes of vaginal discharge in a tertiary care setting. A total of 400 women presenting with vaginal discharge of age between 20 and 50 years, irrespective of marital status were included in this study and women who had used antibiotics or vaginal medication in the previous 14 days and pregnant women were excluded. Of the 400 women with vaginal discharge studied, a diagnosis was established in 303 women. Infectious causes of vaginal discharge were observed in 207 (51.75%) women. Among them, bacterial vaginosis was the most common cause seen in 105 (26.25%) women. The other infections observed were candidiasis alone (61, 15.25%), trichomoniasis alone (12, 3%), mixed infections (22, 5.5%) and mucopurulent cervicitis (7 of the 130 cases looked for, 8.46%). Among the non-infectious causes, 72 (18%) women had physiological vaginal discharge and 13 (3.3%) women had cervical in situ cancers/carcinoma cervix. The pattern of infectious causes of vaginal discharge observed in our study was comparable with the other studies in India. Our study emphasizes the need for including Papanicolaou smear in the algorithm for evaluation of vaginal discharge, as it helps establish the etiology of vaginal discharge reliably and provides a valuable opportunity to screen for cervical malignancies.

  18. Time at which the maximum of a random acceleration process is reached

    International Nuclear Information System (INIS)

    Majumdar, Satya N; Rosso, Alberto; Zoia, Andrea

    2010-01-01

    We study the random acceleration model, which is perhaps one of the simplest, yet nontrivial, non-Markov stochastic processes, and is key to many applications. For this non-Markov process, we present exact analytical results for the probability density p(t m |T) of the time t m at which the process reaches its maximum, within a fixed time interval [0, T]. We study two different boundary conditions, which correspond to the process representing respectively (i) the integral of a Brownian bridge and (ii) the integral of a free Brownian motion. Our analytical results are also verified by numerical simulations.

  19. Prepubertal vaginal discharge: Vaginoscopy to rule out foreign body.

    Science.gov (United States)

    Ekinci, Saniye; Karnak, İbrahim; Tanyel, Feridun Cahit; Çiftçi, Arbay Özden

    2016-01-01

    Medical records of all prepubertal patients who underwent vaginoscopy to rule out vaginal foreign body between 2004 and 2013 were reviewed retrospectively. All patients were evaluated by pediatricians prior to surgical consultation. Vaginoscopy is performed in the operating room under general anesthesia. During the study period, 20 girls with persistent vaginal discharge with a mean age of 6.8 years (1-13 years) underwent vaginoscopy to rule out vaginal foreign body. Six patients had bloody vaginal discharge and 4 had recurrent vaginal bleeding lasting for more than one month. Ten patients had purulent vaginal discharge lasting for 1-7 months. None of vaginal cultures revealed pathological bacteria or candida species. Preoperative imaging techniques revealed vaginal foreign body in one patient only. Vaginoscopy demonstrated vaginal foreign bodies in four patients. Foreign bodies were grass inflorescence, safety pin and undefined brownish particles (n=2), which may be pieces of toilet paper or feces. There was no complication related to vaginoscopy and removal of foreign body. Hymen integrity was preserved in all patients. Persistent or recurrent vaginal discharge in prepubertal girls should raise the suspect of vaginal foreign body. Continuous flow vaginoscopy is mandatory to detect and remove any vaginal foreign body. Early diagnosis would prevent complications secondary to long-standing foreign bodies.

  20. Breast conserving therapy in breast cancer patients presenting with nipple discharge

    International Nuclear Information System (INIS)

    Obedian, Edward; Haffty, Bruce G.

    2000-01-01

    Purpose: To retrospectively review the outcome of conservatively treated breast cancer patients who present with nipple discharge at initial diagnosis. Methods and Materials: The charts of 1097 patients undergoing conservative surgery and radiation therapy between January 1970 and December 1990 were reviewed. All patient data, including clinical, pathologic, treatment, and outcome variables were entered onto a computerized database. For the current study, specific attention was directed to the initial presenting symptoms and patients were divided into two groups: those presenting at initial diagnosis with nipple discharge (D/C-YES, n = 17), and those presenting without nipple discharge (D/C-NO, n = 1080). Results: As of August 1998, with a median follow-up of 12 years, the 10-year actuarial survival, distant metastasis-free survival, and breast relapse-free survival rates for the overall population were 73%, 78%, and 83%, respectively. Although the D/C-YES and D/C-NO groups were well balanced with respect to the majority of clinical factors, the D/C-YES patients had a higher percentage of DCIS histology (7.3% vs 1.2%, p < 0.01), were less likely to undergo reexcision (12% vs 35%), and were more frequently under age 40 (35% vs 12%) than the D/C-NO patients. Over the time span of this study, status of the final surgical margin was indeterminate in the majority of cases. Local relapses occurred in 6 of the 17 patients in the D/C-YES group, resulting in a 10-year actuarial breast relapse-free survival rate of 50%, which was significantly lower than the 10-year breast relapse-free survival rate of 86% in the D/C-NO population. Among the patients presenting with nipple discharge, those with sacrifice of the nipple areolar complex had a lower local relapse rate than those patients who had conservation of the nipple areolar complex (20% vs 42%), although this difference did not reach statistical significance. Conclusions: Although patients presenting with nipple discharge

  1. Characteristics of meter-scale surface electrical discharge propagating along water surface at atmospheric pressure

    International Nuclear Information System (INIS)

    Hoffer, Petr; Sugiyama, Yuki; Hosseini, S Hamid R; Akiyama, Hidenori; Lukes, Petr; Akiyama, Masahiro

    2016-01-01

    This paper reports physical characteristics of water surface discharges. Discharges were produced by metal needle-to-water surface geometry, with the needle electrode driven by 47 kV (FWHM) positive voltage pulses of 2 µ s duration. Propagation of discharges along the water surface was confined between glass plates with 2 mm separation. This allowed generation of highly reproducible 634 mm-long plasma filaments. Experiments were performed using different atmospheres: air, N 2 , and O 2 , each at atmospheric pressure. Time- and spatially-resolved spectroscopic measurements revealed that early spectra of discharges in air and nitrogen atmospheres were dominated by N 2 2nd positive system. N 2 radiation disappeared after approx. 150 ns, replaced by emissions from atomic hydrogen. Spectra of discharges in O 2 atmosphere were dominated by emissions from atomic oxygen. Time- and spatially-resolved emission spectra were used to determine temperatures in plasma. Atomic hydrogen emissions showed excitation temperature of discharges in air to be about 2  ×  10 4 K. Electron number densities determined by Stark broadening of the hydrogen H β line reached a maximum value of ∼10 18 cm −3 just after plasma initiation. Electron number densities and temperatures depended only slightly on distance from needle electrode, indicating formation of high conductivity leader channels. Direct observation of discharges by high speed camera showed that the average leader head propagation speed was 412 km · s −1 , which is substantially higher value than that observed in experiments with shorter streamers driven by lower voltages. (paper)

  2. Recycling behaviour during long pulse discharges after ICRF boronization in the HT-7 tokamak

    International Nuclear Information System (INIS)

    Huang, J.; Wan, B.N.; Li, J.G.; Gong, X.Z.; Zhang, X.D.; Wu, Z.W.; Zhou, Q.

    2006-01-01

    The evolution of recycling behaviour has been investigated during long pulse discharges in the HT-7 tokamak after ICRF boronization (C 2 B 10 H 12 ) using the H/(H+D) ratio and the edge recycling coefficient R. After boronization, impurity reduction is observed, attributed to the fresh boron film, but the recycling coefficient can exceed unity due to a large amount of hydrogen absorbed in the film, leading to an uncontrollable density rise and discharge termination. When the H/(H+D) ratio was reduced to less than 25%, the electron density was easily controlled. The longest discharge, up to 240 s with central electron temperature T e (0) of about 1.0 keV and central electron density n e (0) of 0.8 x 10 19 m -3 , was achieved following boronization. After many discharges the effectiveness of boron film was weakened, and the density rise was correlated with an increase in both carbon and oxygen radiation which limited the duration of long pulse discharges

  3. Estimating groundwater discharge into the ocean in the Yucatán Peninsula

    Science.gov (United States)

    Alvarez Rodriguez, G.; Gutierrez-Jurado, H. A.; Uuh-Sonda, J.

    2017-12-01

    The Yucatán peninsula is an emerged flat carbonate block abundant in soluble rocks. High permeability and dissolution of the rock, facilitates the development of channels, sinkholes and caves where underground rivers discharge into the ocean. There are no rivers or streams acting as a surface drainage system, all rainfall water entering the peninsula is discharged either as evapotranspiration (ET) or as underground runoff into the ocean. To date there are no estimates of the total groundwater discharge from the peninsula into the sea, and of the spatial distribution of recharge and discharge areas thereby hindering efforts to understand the dynamics of a complex hydrologic system. In this study, we estimate the discharge (Q) by solving the water balance equation (ΔS=PPT-ET-Q) using remote sensing products over a period of 12 years; the change in storage (ΔS) was retrieved from the satellite GRACE; precipitation (PPT) from the Tropical Rainfall Measuring Mission; and evapotranspiration (ET) from the Moderate Resolution Imaging Spectroradiometer. Results show that freshwater discharge via evapotranspiration can be a significant portion of the water budget depending on the climatic conditions throughout the year. We observe high recharge-discharge inter-annual variability in the center of the peninsula and some clearly defined recharge and discharge zones around the perimeter. On average the dryer north-east and wetter north-western parts of the peninsula act as recharge zones (where the influx of water is higher than the outflow), while the central-northern part of the peninsula corresponding to agricultural lands, acts as a discharge zone (outflow is higher than influx). The most southern region of the peninsula and the western mangroves are always discharge zones. Finally, our analyses reveal a number of highly subsidized zones, where precipitation levels are consistently lower than evapotranspiration, hence indicating the presence of groundwater dependent

  4. TiN coating on steel by pulsed capillary discharge

    International Nuclear Information System (INIS)

    Avaria, G; Favre, M; Bhuyan, H; Wyndham, E; Kelly, H; Grondona, D; Marquez, A

    2006-01-01

    The characteristic geometry of a pulsed capillary discharge (PCD)[1] establishes natural conditions for the formation of plasma jets, which expand in the chamber's neutral gas. A locally stored capacitor, coaxial with the capillary, is pulse charged to a maximum of -10kV, giving a current pulse of ∼10ns, ∼2kA. The discharge is operated in nitrogen, in a continuous pulsing mode, at a frequency of 50 Hz and pressures of 0.3 to 1 Torr. The coating produced by these plasma jets on substrates of AISI 304 stainless steel have been studied. The chamber's anode is made of titanium, which interacts with the nitrogen plasma producing TiN coatings on the substrates. The results are presented for the plasma characterization at different discharge pressures and times, as well as SEM, EDS and AFM analysis of deposits made. This characterization was carried out using Langmuir double probes, which provide data on the electronic temperature and density in the plasma jet. At the same time spectrographic studies of the plasma were carried out, and the presence of ionized atoms of titanium and nitrogen were observed. An inverse relation between the pressure of nitrogen present in the chamber and the thickness of the coating over steel was found, as well as a direct relationship between the temperature and plasma densities with the thickness of the deposit (CW)

  5. Computational study of plasma sustainability in radio frequency micro-discharges

    International Nuclear Information System (INIS)

    Zhang, Y.; Jiang, W.; Zhang, Q. Z.; Bogaerts, A.

    2014-01-01

    We apply an implicit particle-in-cell Monte-Carlo (PIC-MC) method to study a radio-frequency argon microdischarge at steady state in the glow discharge limit, in which the microdischarge is sustained by secondary electron emission from the electrodes. The plasma density, electron energy distribution function (EEDF), and electron temperature are calculated in a wide range of operating conditions, including driving voltage, microdischarge gap, and pressure. Also, the effect of gap size scaling (in the range of 50-1000 μm) on the plasma sustaining voltage and peak electron density at atmospheric pressure is examined, which has not been explored before. In our simulations, three different EEDFs, i.e., a so-called three temperature hybrid mode, a two temperature α mode, and a two temperature γ mode distribution, are identified at different gaps and voltages. The maximum sustaining voltage to avoid a transition from the glow mode to an arc is predicted, as well as the minimum sustaining voltage for a steady glow discharge. Our calculations elucidate that secondary electrons play an essential role in sustaining the discharge, and as a result the relationship between breakdown voltage and gap spacing is far away from the Paschen law at atmospheric pressure

  6. Maximum entropy PDF projection: A review

    Science.gov (United States)

    Baggenstoss, Paul M.

    2017-06-01

    We review maximum entropy (MaxEnt) PDF projection, a method with wide potential applications in statistical inference. The method constructs a sampling distribution for a high-dimensional vector x based on knowing the sampling distribution p(z) of a lower-dimensional feature z = T (x). Under mild conditions, the distribution p(x) having highest possible entropy among all distributions consistent with p(z) may be readily found. Furthermore, the MaxEnt p(x) may be sampled, making the approach useful in Monte Carlo methods. We review the theorem and present a case study in model order selection and classification for handwritten character recognition.

  7. Discharge Policy and Reperfusion Therapy in Acute Myocardial Infarction

    OpenAIRE

    Vlugt, Maureen

    2007-01-01

    textabstractTreatment of patients with acute myocardial infarction (MI) has improved over time and the duration of hospital stay has considerably decreased. Early hospital discharge after MI has been promoted for over 25 years. However, the meaning of “early” evolved over time. In the early eighties, before the widespread introduction of reperfusion therapy, patients were hospitalised for approximately 3 weeks and early discharge implemented a reduction to 7 days. Nowadays, the average hospit...

  8. Current discharge management of acute coronary syndromes: baseline results from a national quality improvement initiative.

    Science.gov (United States)

    Wai, A; Pulver, L K; Oliver, K; Thompson, A

    2012-05-01

    Evidence-practice gaps exist in the continuum of care for patients with acute coronary syndromes (ACS), particularly at hospital discharge. We aimed to describe the methodology and baseline results of the Discharge Management of Acute Coronary Syndromes (DMACS) project, focusing on the prescription of guideline-recommended medications, referral to cardiac rehabilitation and communication between the hospital, patient and their primary healthcare professionals. DMACS employed Drug Use Evaluation methodology involving data collection, evaluation and feedback, and targeted educational interventions. Adult patients with ACS discharged during a 4-month period were eligible to participate. Data were collected (maximum 50 patients) at each site through an inpatient medical record review, a general practitioner (GP) postal/fax survey conducted 14 days post discharge and a patient telephone survey 3 months post discharge. Forty-nine hospitals participated in the audit recruiting 1545 patients. At discharge, 57% of patients were prescribed a combination of antiplatelet agent(s), beta-blocker, statin and angiotensin-converting enzyme inhibitor and/or angiotensin II-antagonist. At 3 months post discharge, 48% of patients reported using the same combination. Some 67% of patients recalled being referred to cardiac rehabilitation; of these, 33% had completed the programme. In total, 83% of patients had a documented ACS management plan at discharge. Of these, 90% included a medication list, 56% a chest pain action plan and 54% risk factor modification advice. Overall, 65% of GPs rated the quality of information received in the discharge summary as 'very good' to 'excellent'. The findings of our baseline audit showed that despite the robust evidence base and availability of national guidelines, the management of patients with ACS can be improved. These findings will inform a multifaceted intervention strategy to improve adherence to guidelines for the discharge management of

  9. Ion flux nonuniformities in large-area high-frequency capacitive discharges

    International Nuclear Information System (INIS)

    Perret, A.; Chabert, P.; Booth, J.-P.; Jolly, J.; Guillon, J.; Auvray, Ph.

    2003-01-01

    Strong nonuniformities of plasma production are expected in capacitive discharges if the excitation wavelength becomes comparable to the reactor size (standing-wave effect) and/or if the plasma skin depth becomes comparable to the plate separation (skin effect) [M. A. Lieberman et al., Plasma Sources Sci. Technol. 11, 283 (2002)]. Ion flux uniformity measurements were carried out in a large-area square (40 cmx40 cm) capacitive discharge driven at frequencies between 13.56 MHz and 81.36 MHz in argon gas at 150 mTorr. At 13.56 MHz, the ion flux was uniform to ±5%. At 60 MHz (and above) and at low rf power, the standing-wave effect was seen (maximum of the ion flux at the center), in good quantitative agreement with theory. At higher rf power, maxima of the ion flux were observed at the edges, due either to the skin effect or to other edge effects

  10. Maximum Entropy Fundamentals

    Directory of Open Access Journals (Sweden)

    F. Topsøe

    2001-09-01

    Full Text Available Abstract: In its modern formulation, the Maximum Entropy Principle was promoted by E.T. Jaynes, starting in the mid-fifties. The principle dictates that one should look for a distribution, consistent with available information, which maximizes the entropy. However, this principle focuses only on distributions and it appears advantageous to bring information theoretical thinking more prominently into play by also focusing on the "observer" and on coding. This view was brought forward by the second named author in the late seventies and is the view we will follow-up on here. It leads to the consideration of a certain game, the Code Length Game and, via standard game theoretical thinking, to a principle of Game Theoretical Equilibrium. This principle is more basic than the Maximum Entropy Principle in the sense that the search for one type of optimal strategies in the Code Length Game translates directly into the search for distributions with maximum entropy. In the present paper we offer a self-contained and comprehensive treatment of fundamentals of both principles mentioned, based on a study of the Code Length Game. Though new concepts and results are presented, the reading should be instructional and accessible to a rather wide audience, at least if certain mathematical details are left aside at a rst reading. The most frequently studied instance of entropy maximization pertains to the Mean Energy Model which involves a moment constraint related to a given function, here taken to represent "energy". This type of application is very well known from the literature with hundreds of applications pertaining to several different elds and will also here serve as important illustration of the theory. But our approach reaches further, especially regarding the study of continuity properties of the entropy function, and this leads to new results which allow a discussion of models with so-called entropy loss. These results have tempted us to speculate over

  11. Predicting discharge in forensic psychiatry: the legal and psychosocial factors associated with long and short stays in forensic psychiatric hospitals.

    Science.gov (United States)

    Ross, Thomas; Querengässer, Jan; Fontao, María Isabel; Hoffmann, Klaus

    2012-01-01

    In Germany, both the number of patients treated in forensic psychiatric hospitals and the average inpatient treatment period have been increasing for over thirty years. Biographical and clinical factors, e.g., the number of prior offences, type of offence, and psychiatric diagnosis, count among the factors that influence the treatment duration and the likelihood of discharge. The aims of the current study were threefold: (1) to provide an estimate of the German forensic psychiatric patient population with a low likelihood of discharge, (2) to replicate a set of personal variables that predict a relatively high, as opposed to a low, likelihood of discharge from forensic psychiatric hospitals, and (3) to describe a group of other factors that are likely to add to the existing body of knowledge. Based on a sample of 899 patients, we applied a battery of primarily biographical and other personal variables to two subgroups of patients. The first subgroup of patients had been treated in a forensic psychiatric hospital according to section 63 of the German legal code for at least ten years (long-stay patients, n=137), whereas the second subgroup had been released after a maximum treatment period of four years (short-stay patients, n=67). The resulting logistic regression model had a high goodness of fit, with more than 85% of the patients correctly classified into the groups. In accordance with earlier studies, we found a series of personal variables, including age at first admission and type of offence, to be predictive of a short or long-stay. Other findings, such as the high number of immigrants among the short-stay patients and the significance of a patient's work time before admission to a forensic psychiatric hospital, are more clearly represented than has been observed in previous research. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. MHD analysis of high (βt) disruptions in PBX

    International Nuclear Information System (INIS)

    Jahns, G.L.; Chance, M.S.; Kaye, S.M.; Manickam, J.; Takahashi, H.; LeBlanc, B.; Morris, A.W.; Reusch, M.; Sesnic, S.

    1988-01-01

    Princeton Beta Experiment (PBX) discharges run at the lowest q and highest (β t ) always terminated in a hard disruption. The discharges, with (β t ) values of up to 5.5% and q-values down to 2.2, were obtained by employing large current ramps and large gas feed rates during neutral beam injection. Previous work has indicated that the achieved (β t ) values were consistent with the limit imposed by the n=1 ideal external kink with a conducting wall at b/a=2. The authors of the paper investigate further the validity of ideal MHD theory in explaining the low q ψ disruptions. In particular, the characteristics of the pre-disruption MHD activity in these low-q discharges, specifically the time-scale of growth and internal and external mode structures, are compared with those determined from theoretical calculations. The results of these comparisons indicate that non-ideal effects must be considered in order to obtain detailed agreement between theory and experiment. (author). 13 refs, 6 figs

  13. Vaginal foreign body causing recurrent discharge and vaginal stenosis--a case report.

    Science.gov (United States)

    Gurung, Geeta; Rana, Ashma; Amatya, Archana

    2007-06-01

    Chronic vaginal discharge in children and adolescents is a common gynaecological complaint which is often resistant to antibiotic treatment. We present a 14 years old, premenarcheal girl who presented to us with the complaints of recurrent, foul smelling purulent occasionally blood stained vaginal discharge for eight years, where a foreign body in the upper vagina was found after releasing a dense adhesion of the lower vagina which was unable to detect by pelvic ultrasound.

  14. Chronic consequences of acute injuries: worse survival after discharge.

    Science.gov (United States)

    Shafi, Shahid; Renfro, Lindsay A; Barnes, Sunni; Rayan, Nadine; Gentilello, Larry M; Fleming, Neil; Ballard, David

    2012-09-01

    The Trauma Quality Improvement Program uses inhospital mortality to measure quality of care, which assumes patients who survive injury are not likely to suffer higher mortality after discharge. We hypothesized that survival rates in trauma patients who survive to discharge remain stable afterward. Patients treated at an urban Level I trauma center (2006-2008) were linked with the Social Security Administration Death Master File. Survival rates were measured at 30, 90, and 180 days and 1 and 2 years from injury among two groups of trauma patients who survived to discharge: major trauma (Abbreviated Injury Scale score ≥ 3 injuries, n = 2,238) and minor trauma (Abbreviated Injury Scale score ≤ 2 injuries, n = 1,171). Control groups matched to each trauma group by age and sex were simulated from the US general population using annual survival probabilities from census data. Kaplan-Meier and log-rank analyses conditional upon survival to each time point were used to determine changes in risk of mortality after discharge. Cox proportional hazards models with left truncation at the time of discharge were used to determine independent predictors of mortality after discharge. The survival rate in trauma patients with major injuries was 92% at 30 days posttrauma and declined to 84% by 3 years (p > 0.05 compared with general population). Minor trauma patients experienced a survival rate similar to the general population. Age and injury severity were the only independent predictors of long-term mortality given survival to discharge. Log-rank tests conditional on survival to each time point showed that mortality risk in patients with major injuries remained significantly higher than the general population for up to 6 months after injury. The survival rate of trauma patients with major injuries remains significantly lower than survival for minor trauma patients and the general population for several months postdischarge. Surveillance for early identification and treatment of

  15. Conversion of carbon dioxide to value-added chemicals in atmospheric pressure dielectric barrier discharges

    International Nuclear Information System (INIS)

    Paulussen, Sabine; Verheyde, Bert; Tu Xin; Sels, Bert; De Bie, Christophe; Martens, Tom; Petrovic, Dragana; Bogaerts, Annemie

    2010-01-01

    The aim of this work consists of the evaluation of atmospheric pressure dielectric barrier discharges for the conversion of greenhouse gases into useful compounds. Therefore, pure CO 2 feed flows are administered to the discharge zone at varying discharge frequency, power input, gas temperature and feed flow rates, aiming at the formation of CO and O 2 . The discharge obtained in CO 2 is characterized as a filamentary mode with a microdischarge zone in each half cycle of the applied voltage. It is shown that the most important parameter affecting the CO 2 -conversion levels is the gas flow rate. At low flow rates, both the conversion and the CO-yield are significantly higher. In addition, also an increase in the gas temperature and the power input give rise to higher conversion levels, although the effect on the CO-yield is limited. The optimum discharge frequency depends on the power input level and it cannot be unambiguously stated that higher frequencies give rise to increased conversion levels. A maximum CO 2 conversion of 30% is achieved at a flow rate of 0.05 L min -1 , a power density of 14.75 W cm -3 and a frequency of 60 kHz. The most energy efficient conversions are achieved at a flow rate of 0.2 L min -1 , a power density of 11 W cm -3 and a discharge frequency of 30 kHz.

  16. 3T deep gray matter T2 hypointensity correlates with disability over time in stable relapsing-remitting multiple sclerosis: a 3-year pilot study.

    Science.gov (United States)

    Zhang, Y; Metz, L M; Yong, V W; Mitchell, J R

    2010-10-15

    Abnormally decreased deep gray matter (GM) signal intensity on T2-weighted MRI (T2 hypointensity) is associated with brain atrophy and disability progression in patients with multiple sclerosis (MS) and is believed to represent excessive iron deposition. We investigated the time course of deep GM T2 hypointensity and its relationship with disability at 3T in 8 stable relapsing-remitting (RR) MS patients treated with minocycline over 3years. MRI and disability measurements were compared at baseline, 6, 12, 24, and 36months. Grand mean deep GM T2 hypointensity was negatively correlated with EDSS over time (r=-0.94, P=0.02). This correlation was strongest in the head of caudate (r=-0.95, P=0.01) and putamen (r=-0.89, P=0.04). Additionally, baseline grand mean deep GM T2 hypointensity appears to predict third year EDSS (r=-0.72, P=0.04). These results suggest that iron associated deep GM injury correlates with patient disability in stable RRMS. Measurements of deep GM T2 hypointensity at high field MRI may prove to be useful in monitoring individuals with MS. Further studies are required to confirm these results in a large sample and to determine if T2 hypointensity changes in clinically active MS patients. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Processing device for discharged water from radioactive material handling facility

    International Nuclear Information System (INIS)

    Kono, Takao; Kono, Hiroyuki; Yasui, Katsuaki; Kataiki, Koichi.

    1995-01-01

    The device of the present invention comprises a mechanical floating material-removing means for removing floating materials in discharged water, an ultrafiltration device for separating processed water discharged from the removing means by membranes, a reverse osmotic filtration device for separating the permeated water and a condensing means for evaporating condensed water. Since processed water after mechanically removing floating materials is supplied to the ultrafiltration device, the load applied on the filtering membrane is reduced, to simplify the operation control as a total. In addition, since the amount of resultant condensed water is reduced, and the devolumed condensed water is condensed and dried, the condensing device is made compact and the amount of resultant wastes is reduced. (T.M.)

  18. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  19. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  20. History of Discharge of Radionuclide from Nuclear Malaysia Research Reactor

    International Nuclear Information System (INIS)

    Mohd Nahar Othman; Ismail Sulaiman

    2013-01-01

    After more than 40 years the operation of Malaysian Nuclear Agency research reactor, this is the first time, the discharge emission radionuclide to environment is recorded and analyzed in detail. Starting from 1984, radionuclide Ar-41 had been analyzed manually by Research Officers but their finding is not recorded in any Journal. That is responsible of Safety and Health Division to make sure the safety of the workers and public living around Malaysian Nuclear Agency receive safe dose. This paper will report dose that had been discharge to the environment starting from 1984 to 2012 and it detail calculations.After more than 40 years the operation of Malaysian Nuclear Agency research reactor, this is the first time, the discharge emission radionuclide to environment is recorded and analyzed in detail. Starting from 1984, radionuclide Ar-41 had been analyzed manually by Research Officers but their finding is not recorded in any Journal. That is responsible of Safety and Health Division to make sure the safety of the workers and public living around Malaysian Nuclear Agency receive safe dose. This paper will report dose that had been discharge to the environment starting from 1984 to 2012 and it detail calculations. (author)

  1. Spatial Characteristics and Driving Factors of Provincial Wastewater Discharge in China.

    Science.gov (United States)

    Chen, Kunlun; Liu, Xiaoqiong; Ding, Lei; Huang, Gengzhi; Li, Zhigang

    2016-12-09

    Based on the increasing pressure on the water environment, this study aims to clarify the overall status of wastewater discharge in China, including the spatio-temporal distribution characteristics of wastewater discharge and its driving factors, so as to provide reference for developing "emission reduction" strategies in China and discuss regional sustainable development and resources environment policies. We utilized the Exploratory Spatial Data Analysis (ESDA) method to analyze the characteristics of the spatio-temporal distribution of the total wastewater discharge among 31 provinces in China from 2002 to 2013. Then, we discussed about the driving factors, affected the wastewater discharge through the Logarithmic Mean Divisia Index (LMDI) method and classified those driving factors. Results indicate that: (1) the total wastewater discharge steadily increased, based on the social economic development, with an average growth rate of 5.3% per year; the domestic wastewater discharge is the main source of total wastewater discharge, and the amount of domestic wastewater discharge is larger than the industrial wastewater discharge. There are many spatial differences of wastewater discharge among provinces via the ESDA method. For example, provinces with high wastewater discharge are mainly the developed coastal provinces such as Jiangsu Province and Guangdong Province. Provinces and their surrounding areas with low wastewater discharge are mainly the undeveloped ones in Northwest China; (2) The dominant factors affecting wastewater discharge are the economy and technological advance; The secondary one is the efficiency of resource utilization, which brings about the unstable effect; population plays a less important role in wastewater discharge. The dominant driving factors affecting wastewater discharge among 31 provinces are divided into three types, including two-factor dominant type, three-factor leading type and four-factor antagonistic type. In addition, the

  2. Self-Determination Theory Application In The Discharge Of Patients With Transient Ischemic Attack

    Directory of Open Access Journals (Sweden)

    Tahere Sarboozi Hosein Abadi

    2017-02-01

    Full Text Available Background: The principle of transient ischemic attack treatment is lifestyle modification and pharmacological treatment that would reduce recurrence and incidence of stroke. Lifestyle changes require follow-up care and continuity of nurse and patient relationships, but the current training does not meet this need. The trainings based on motivating theory such as self-determination, besides continuity of the relationship with patient, improve his/her incentive, specially of it is carried out at the discharge time. Therefore, this study has been done by the purpose of defining the impact of discharge plan based on self-determination theory on the lifestyle patients with transient ischemic attack. Methodology: The analysis has been done on 57, 18-90 years old clinical random patients in Tehran hospitals (29 cases and 28 controls in 2015. Data were collected by demographic questionnaire at the beginning and health-promoting lifestyle questionnaire(second edition were collected at the end of the study. Discharge plan based on self-determination theory, including patients and families meeting in hospital and telephone counseling during the 12 weeks after discharge was accomplished in cases group. The control group received only routine hospital care. Data were analyzed by t-test and chi- squre test. Results: The score of lifestyle was similar in both groups (p> .05 at beginning of the study, but at the end of the study, the average score of cases group (17.1 ± 164.2 significantly higher than the control group (17.6 ± 118.3 (p < 0.001. Furthermore, At the end of study, the mean scores of nutrition, physical activity, stress management, interpersonal relationships, spiritual growth and responsibility in the lifestyle cases group was significantly higher than the control group (p <.001. The frequency of transient ischemic attacks after discharge in the cases group (13.8%, significantly lower than the control group (46.4%, respectively (p = .016

  3. Increased West Antarctic and unchanged East Antarctic ice discharge over the last 7 years

    NARCIS (Netherlands)

    Gardner, Alex S.; Moholdt, Geir; Scambos, Ted; Fahnstock, Mark; Ligtenberg, Stefan; van den Broeke, Michiel; Nilsson, Johan

    2018-01-01

    Ice discharge from large ice sheets plays a direct role in determining rates of sea-level rise. We map present-day Antarctic-wide surface velocities using Landsat 7 and 8 imagery spanning 2013–2015 and compare to earlier estimates derived from synthetic aperture radar, revealing heterogeneous

  4. Modelling groundwater discharge areas using only digital elevation models as input data

    Energy Technology Data Exchange (ETDEWEB)

    Brydsten, Lars [Umeaa Univ. (Sweden). Dept. of Biology and Environmental Science

    2006-10-15

    Advanced geohydrological models require data on topography, soil distribution in three dimensions, vegetation, land use, bedrock fracture zones. To model present geohydrological conditions, these factors can be gathered with different techniques. If a future geohydrological condition is modelled in an area with positive shore displacement (say 5,000 or 10,000 years), some of these factors can be difficult to measure. This could include the development of wetlands and the filling of lakes. If the goal of the model is to predict distribution of groundwater recharge and discharge areas in the landscape, the most important factor is topography. The question is how much can topography alone explain the distribution of geohydrological objects in the landscape. A simplified description of the distribution of geohydrological objects in the landscape is that groundwater recharge areas occur at local elevation curvatures and discharge occurs in lakes, brooks, and low situated slopes. Areas in-between these make up discharge areas during wet periods and recharge areas during dry periods. A model that could predict this pattern only using topography data needs to be able to predict high ridges and future lakes and brooks. This study uses GIS software with four different functions using digital elevation models as input data, geomorphometrical parameters to predict landscape ridges, basin fill for predicting lakes, flow accumulations for predicting future waterways, and topographical wetness indexes for dividing in-between areas based on degree of wetness. An area between the village of and Forsmarks' Nuclear Power Plant has been used to calibrate the model. The area is within the SKB 10-metre Elevation Model (DEM) and has a high-resolution orienteering map for wetlands. Wetlands are assumed to be groundwater discharge areas. Five hundred points were randomly distributed across the wetlands. These are potential discharge points. Model parameters were chosen with the

  5. Discharge reductions-value for money?

    International Nuclear Information System (INIS)

    Morley, R G; Coates, R; Taylor, R H

    2004-01-01

    Through the Nuclear Liabilities Management Authority White Paper, the UK Government and the Regulators have signalled a commitment to further improving the operation of the regulatory regime and to its operating within the principles of proportionality, transparency, consistency and accountability which underpin the Government's approach to regulation in general. Particular emphasis is placed upon ensuring that there is greater consistency in the treatment of risk and hazard; proportionate and cost effective delivery of public, worker and environmental protection; and an open and transparently applied regulatory system. The paper uses the historical record of radioactive discharges from BNFL's Sellafield reprocessing site in the UK and seeks to identify what have been the key drivers for change, particularly over the past 20 years of significant discharge reductions. The paper examines the current context for ongoing and future discharges from the site, and the incorporation of the use of the concepts of best practicable environmental option and best practicable means. Intergovernmental commitments such as the OSPAR Sintra and Bremen statements and the developing UK policy framework are also considered, together with BNFL's work with a wide range of 'green' stakeholders. The paper outlines the principal components of BNFL's decision-making processes for discharge control and abatement; and how these interact with the relevant external pressures. It then analyses whether the overall drivers and outcomes align with the declared desire of the UK Government to ensure that the taxpayer receives value for money in the new national arrangements for managing historic nuclear liabilities

  6. Examining the Utility of Coral Ba/Ca as a Paleo-Proxy for Interannual River Discharge Variability Along the Pacific Coast of Panamá

    Science.gov (United States)

    Brenner, L. D.; Linsley, B. K.; Dunbar, R. B.

    2016-02-01

    Climate along the Pacific coast of Panamá is largely dictated by seasonal N/S shifts in the Intertropical Convergence zone (ITCZ) and the consequent oscillations in precipitation. During the Panamanian wet season (May-Nov.) river discharge (Q) reaches its maximum and serves as a potential source of trace elements, such as Ba, to reefs. Near shore corals can record the waterborne trace metal history in their aragonite skeletons, which can then be exploited as a paleo-proxy for river discharge. We present two high-resolution Ba/Ca records from nearby Porites corals in the Gulf of Chiriquí, Panamá in an effort to better understand the long-term discharge and precipitation history of the region. Both corals record similar annual average Ba/Ca values throughout the time series' (R=0.55) suggesting that they are faithfully recording water column Ba levels at a large scale. A monthly composite average of both coral Ba/Ca records is positively correlated to an average of all available river discharge data (n= 5) (R=0.42). While instrumental data are relatively sparse and discontinuous, there is a significant relationship between the two variables producing a Ba/Ca-discharge relationship where Q (m3/s)= Ba/Ca(μmol/mol)×49.97(μmol/mol)(m3/s)-1-190.85. The Ba/Ca peaks correspond to the annual minima in our paired near-monthly resolved coral δ18O measurements, further supporting that maximum Q in the Gulf is concurrent with the annual salinity minima and precipitation maximum. Coral Ba/Ca in the Gulf of Chiriquí indicates that annual average river Q into the Gulf has varied from 50 to 133 m3/s over from 1966 to 1983. As inferred from our Ba/Ca data, interannual variability of river Q accounts for 25% of total variance (after removing the seasonal cycle) and a long-term secular trend of increasing river Q accounts for 30%. Our Porites coral Ba/Ca records from the Pacific side of Panamá provide an opportunity to supplement the limited instrumental river discharge data

  7. Discharge Characteristics of Series Surface/Packed-Bed Discharge Reactor Diven by Bipolar Pulsed Power

    International Nuclear Information System (INIS)

    Hu Jian; Jiang Nan; Li Jie; Shang Kefeng; Lu Na; Wu Yan; Mizuno Akira

    2016-01-01

    The discharge characteristics of the series surface/packed-bed discharge (SSPBD) reactor driven by bipolar pulse power were systemically investigated in this study. In order to evaluate the advantages of the SSPBD reactor, it was compared with traditional surface discharge (SD) reactor and packed-bed discharge (PBD) reactor in terms of the discharge voltage, discharge current, and ozone formation. The SSPBD reactor exhibited a faster rising time and lower tail voltage than the SD and PBD reactors. The distribution of the active species generated in different discharge regions of the SSPBD reactor was analyzed by optical emission spectra and ozone analysis. It was found that the packed-bed discharge region (3.5 mg/L), rather than the surface discharge region (1.3 mg/L) in the SSPBD reactor played a more important role in ozone generation. The optical emission spectroscopy analysis indicated that more intense peaks of the active species (e.g. N2 and OI) in the optical emission spectra were observed in the packed-bed region. (paper)

  8. Spectroscopic diagnosis of plasma in atmospheric pressure negative pulsed gas-liquid discharge with nozzle-cylinder electrode

    Science.gov (United States)

    Ming, SUN; Zhan, TAO; Zhipeng, ZHU; Dong, WANG; Wenjun, PAN

    2018-05-01

    The plasma characteristics of a gas-liquid phase discharge reactor were investigated by optical and electrical methods. The nozzle-cylinder electrode in the discharge reactor was supplied with a negative nanosecond pulsed generator. The optical emission spectrum diagnosis revealed that OH (A2∑+ → X2Π, 306–309 nm), N2 (C3Π→B3Πg, 337 nm), O (3p5p→3s5s0, 777.2 nm) and O (3p3p→3s3s0, 844.6 nm) were produced in the discharge plasma channels. The electron temperature (T e) was calculated from the emission relative intensity ratio between the atomic O 777.2 nm and 844.6 nm, and it increased with the applied voltage and the pulsed frequency and fell within the range of 0.5–0.8 eV. The gas temperature (T g) that was measured by Lifbase was in a range from 400 K to 600 K.

  9. Nonstationary ARCH and GARCH with t-distributed Innovations

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Søndergaard; Rahbek, Anders

    Consistency and asymptotic normality are established for the maximum likelihood estimators in the nonstationary ARCH and GARCH models with general t-distributed innovations. The results hold for joint estimation of (G)ARCH effects and the degrees of freedom parameter parametrizing the t-distribut......Consistency and asymptotic normality are established for the maximum likelihood estimators in the nonstationary ARCH and GARCH models with general t-distributed innovations. The results hold for joint estimation of (G)ARCH effects and the degrees of freedom parameter parametrizing the t......-distribution. With T denoting sample size, classic square-root T-convergence is shown to hold with closed form expressions for the multivariate covariances....

  10. High tension generator for corona barrier discharge

    International Nuclear Information System (INIS)

    Baltag, O.; Costandache, D.; Gheorghiu, M.; Paraschivescu, A.; Popa, G.

    2001-01-01

    Different types of high-voltage generators are in use for the study of low pressure (or atmospheric) discharges. Mostly used are the Tesla coils generators or the power generators working in linear or switching regime. The Tesla coils generators have the advantage of a simple bloc diagram. In exchange, they have a number of short-comings, such as: the difficulty in modifying the frequency of the high voltage pulses, generation of a high voltage and frequency pulse train, the amplitude is not constant.This paper presents a high-voltage generator meant to be used in the study of the dielectric barrier discharges (DBD). The bloc diagram is presented. Performances obtained are as follows: - Generated frequency: 10 Hz - 100 Hz, 100 Hz - 1 KHz, 1 KHz - 10 KHz; - High voltage pulses control: a single pulse from an internal or external generator; - Synchronization with the oscilloscope, variable delay: 5 μs - 0.1 s; - Output voltage: variable both smoothly and in steps: 1 kV -15 kV; - High voltage polarity: mono and bipolar; - Output power during the continuous duty: 300 VA (maximum 600 VA for a short time); - Pulse energy: 0.23 J; - Pulse duration: 4 μs - 50 μs

  11. Humidity effects on surface dielectric barrier discharge for gaseous naphthalene decomposition

    Science.gov (United States)

    Abdelaziz, Ayman A.; Ishijima, Tatsuo; Seto, Takafumi

    2018-04-01

    Experiments are performed using dry and humid air to clarify the effects of water vapour on the characteristics of surface dielectric barrier discharge (SDBD) and investigate its impact on the performance of the SDBD for decomposition of gaseous naphthalene in air stream. The current characteristics, including the discharge and the capacitive currents, are deeply analyzed and the discharge mechanism is explored. The results confirmed that the humidity affected the microdischarge distribution without affecting the discharge mode. Interestingly, it is found that the water vapour had a significant influence on the capacitance of the reactor due to its deposition on the discharge electrode and the dielectric, which, in turn, affects the power loss in the dielectric and the total power consumed in the reactor. Thus, the factor of the humidity effect on the power loss in the dielectric should be considered in addition to its effect on the attachment coefficient. Additionally, there was an optimum level of the humidity for the decomposition of naphthalene in the SDBD, and its value depended on the gas composition, where the maximum naphthalene decomposition efficiency in O2/H2O is achieved at the humidity level ˜10%, which was lower than that obtained in air/H2O (˜28%). The results also revealed that the role of the humidity in the decomposition efficiency was not significant in the humidified O2 at high power level. This was attributed to the significant increase in oxygen-derived species (such as O atoms and O3) at high power, which was enough to overcome the negative effects of the humidity.

  12. Demonstration of high performance negative central magnetic shear discharges on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Rice, B.W.; Burrell, K.H.; Lao, L.L.

    1996-01-01

    Reliable operation of discharges with negative central magnetic shear has led to significant increases in plasma performance and reactivity in both low confinement, L-mode, and high confinement, H-mode, regimes in the DIII-D tokamak. Using neutral beam injection early in the initial current ramp, a large range of negative shear discharges have been produced with durations lasting up to 3.2 s. The total non- inductive current (beam plus bootstrap) ranges from 50% to 80% in these discharges. In the region of shear reversal, significant peaking of the toroidal rotation [f φ ∼ 30-60 kHz] and ion temperature [T i (0) ∼ 15-22 keV] profiles are observed. In high power discharges with an L-mode edge, peaked density profiles are also observed. Confinement enhancement factors up to H ≡ τ E /τ ITER-89P ∼ 2.5 with an L-mode edge, and H ∼ 3.3 in an Edge Localized Mode (ELM)-free H-mode, are obtained. Transport analysis shows both ion thermal diffusivity and particle diffusivity to be near or below standard neoclassical values in the core. Large pressure peaking in L- mode leads to high disruptivity with Β N ≡ Β T /(I/aB) ≤ 2.3, while broader pressure profiles in H- mode gives low disruptivity with Β N ≤ 4.2

  13. Prostate brachytherapy - discharge

    Science.gov (United States)

    Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge ... You had a procedure called brachytherapy to treat prostate cancer. Your treatment lasted 30 minutes or more, ...

  14. Discharges and impacts from la Hague plant: history and recent achievements

    International Nuclear Information System (INIS)

    Kalimbadjian, J.; Rincel, X.

    1998-01-01

    Industrial reprocessing at La Hague was started in 1966. During 30 years. the annual rate of production gradually increased, up to more than 1,600 tons. Simultaneously, considerable innovative design and technology was introduced at all steps of the process, including effluent treatment and waste management. The characteristics of reprocessed fuel elements also changed. from low burn-up metallic fuel to high burn-up oxides. Reflecting all those evolutions, the plant discharges to the atmosphere and to the sea have shown significant variations in quantity and in composition. The complete history of liquid and gaseous releases displays a broad spectrum of situations, as to the relative weight of each radionuclide. However, the level of discharge has always remained significantly lower than the authorized limits. whatever radionuclide. Moreover, discharges to the sea have continuously decreased for 10 years, in spite of fast rising rate of production. As to the total radiological impact of discharges. it was permanently maintained well within the acceptable level of 0.15 mSv/year for the reference groups of neighbouring population, as decided for the level of authorizations. Since 1988, several actions have been decided in order to minimize the present and future impacts: improved liquid effluent treatment, extended recycling of liquid effluents towards vitrification, supplementary filtration of gaseous effluents for iodine scavenging. As a result, the plant will be able to maintain the overall impact from all discharges at less than the present acceptable level, in spite of projected wider domain of operations: - modified grades of reprocessed fuel, - decommissioning operations; - treatment of older waste stocks. (author)

  15. Plutonium isotopic composition of high burnup spent fuel discharged from light water reactors

    International Nuclear Information System (INIS)

    Nakano, Yoshihiro; Okubo, Tsutomu

    2011-01-01

    Highlights: → Pu isotopic composition of fuel affects FBR core nuclear characteristics very much. → Spent fuel compositions of next generation LWRs with burnup of 70 GWd/t were obtained. → Pu isotopic composition and amount in the spent fuel with 70 GWd/t were evaluated. → Spectral shift rods of high burnup BWR increases the fissile Pu fraction of spent fuel. → Wide fuel rod pitch of high burnup PWR lowers the fissile Pu fraction of spent fuel. - Abstract: The isotopic composition and amount of plutonium (Pu) in spent fuel from a high burnup boiling water reactor (HB-BWR) and a high burnup pressurized water reactor (HB-PWR), each with an average discharge burnup of 70 GWd/t, were estimated, in order to evaluate fast breeder reactor (FBR) fuel composition in the transition period from LWRs to FBRs. The HB-BWR employs spectral shift rods and the neutron spectrum is shifted through the operation cycle. The weight fraction of fissile plutonium (Puf) isotopes to the total plutonium in HB-BWR spent fuel after 5 years cooling is 62%, which is larger than that of conventional BWRs with average burnup of 45 GWd/t, because of the spectral shift operation. The amount of Pu produced in the HB-BWR is also larger than that produced in a conventional BWR. The HB-PWR uses a wider pitch 17 x 17 fuel rod assembly to optimize neutron slowing down. The Puf fraction of HB-PWR spent fuel after 5 years cooling is 56%, which is smaller than that of conventional PWRs with average burnup of 49 GWd/t, mainly because of the wider pitch. The amount of Pu produced in the HB-PWR is also smaller than that in conventional PWRs.

  16. Confinement of a non cylindrical z discharge by a cusp geometry

    International Nuclear Information System (INIS)

    Watteau, J.H.

    1968-03-01

    The plasma of a non-cylindrical z discharge is accumulated in the centre of a cusp geometry and then captured and confined by the rising cusp magnetic field. The cusp geometry is produced by two identical coaxial coils the currents of which are equal but in opposite directions. Stability and confinement properties of this zero minimum B geometry are recalled; in particular it is shown (the coils cross section being supposed punctual) that the magnetic well depth of the configuration without plasma is maximum for an optimum coils distance. Two modes of confinement are observed experimentally : - a collisional mode for which the plasma confinement is limited to 10 μsec (temperature 5 eV, density 7 x 10 16 cm -3 ) as a result of the gradual interpenetration of the plasma and of the magnetic field. - a collisionless mode (temperature 40 eV) where the radial leak thickness is of the order of the ion cyclotron radius. Plasma accumulation occurs even without confinement and is due to the non-cylindrical shape of the discharge chamber. The two-dimensional snow-plough model gives good account of the discharge dynamics. A comparison is made with plasma focus experiments: in particular experimental conditions (deuterium, pressure 1 torr,energy 3 kJ, current 100 kA) a 10 7 neutron yield is detected which appears to be connected with the unstable behavior of the discharge. (authors) [fr

  17. Mechanical properties of ultrananocryslalline thin films deposited using dual frequency discharges

    Czech Academy of Sciences Publication Activity Database

    Buršíková, V.; Bláhová, O.; Karásková, M.; Zajíčková, L.; Jašek, O.; Franta, D.; Klapetek, P.; Buršík, Jiří

    2011-01-01

    Roč. 105, - (2011), s. 98-101 ISSN 0009-2770. [Lokální mechanické vlastnosti ´07. Brno, 07.11.2007-09.11.2007] Institutional research plan: CEZ:AV0Z20410507 Keywords : ultrananocryslalline diamond * plasma enhanced chemical vapor deposition * dual frequency discharge Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.529, year: 2011

  18. THE ANALYSIS OF THE SEWAGE QUANTITY DISCHARGING FROM THE SEWERAGE AGGLOMERATION IN SANOK

    Directory of Open Access Journals (Sweden)

    Anna Młyńska

    2017-06-01

    Full Text Available Both too large and too small volume of sewage inflowing to wastewater treatment plant in relation to its volume determined during designing process, can contribute to the reduction of sewage treatment effectiveness. Taking into consideration, in this article, the analysis of the sewage quantity discharging from the Sanok agglomeration and treated in domestic wastewater treatment plant in 2013-2015 was performed. The analysis indicated that in each year of the analyzed period, to the Wastewater Treatment Plant in Trepcza, a similar volumes of sewage was inflowing and the maximum hydraulic capacity of the object was not exceeded, what is evidenced by the average daily sewage flow values. It is noted that in rainless periods, the quantities of inflowing sewage were smaller than during days with wet weather. Despite of periodically situations of the hydraulic overload and hydraulic underload, it can be stated that the effectiveness of the sewage treatment processes is not endangered by the excessive or insufficient quantities of inflowing sewage.

  19. Dielectric barrier discharges applied for optical spectrometry

    Czech Academy of Sciences Publication Activity Database

    Brandt, S.; Schütz, A.; Klute, F. D.; Kratzer, Jan; Franzke, J.

    2016-01-01

    Roč. 123, SEP (2016), s. 6-32 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * analytical spectroscopy * applications Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 3.241, year: 2016

  20. Dielectric barrier discharges applied for optical spectrometry

    Czech Academy of Sciences Publication Activity Database

    Brandt, S.; Schütz, A.; Klute, F. D.; Kratzer, Jan; Franzke, J.

    2016-01-01

    Roč. 123, SEP (2016), s. 6-32 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * analytical spectroscopy * applications Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.241, year: 2016

  1. Characterization of stormwater discharges from Las Flores Industrial Park, Rio Grande, Puerto Rico, 1998-99

    Science.gov (United States)

    Rodriguez, Jose M.

    2000-01-01

    Stormwater discharges from Las Flores Industrial Park, Rio Grande, Puerto Rico, were characterized from June 1998 to July 1999 by measuring the flow rate at two outfalls, delineating the drainage areas for each outfall, and calculating the volume of the stormwater discharges. Stormwater-discharge samples were collected and analyzed to determine the quality of the discharges. Constituent loads and loads per area were estimated for each drainage area. The studied drainage subareas covered approximately 46 percent of the total area of the Las Flores Industrial Park. Industrial groups represented in the study areas include manufacturers of textile, electronics, paper, fabricated metal, plastic, and chemical products. The concentrations of oil and grease (1 to 6 milligrams per liter), biochemical oxygen demand (4.7 to 16 milligrams per liter), total organic carbon (5.8 to 36 milligrams per liter), total suspended solids (28 to 100 milligrams per liter), and total phosphorous (0.11 to 0.78 milligrams per liter) from all the samples collected were less than the U.S. Environmental Protection Agency stormwater benchmark concentrations. Concentrations of chemical oxygen demand (15.8 to 157 milligrams per liter) and nitrate and nitrite (0.06 to 1.75 milligrams per liter) exceeded benchmark concentrations at one of the studied drainage areas. Total Kjeldahl nitrogen concentrations (1.00 to 3.20 milligrams per liter) exceeded the benchmark concentrations at the two studied drainage areas. Maximum concentrations for oil and grease, biochemical oxygen demand, chemical oxygen demand, total organic carbon, total Kjeldahl nitrogen, nitrate plus nitrite, and total phosphorous were detected in an area where electronics, plastics, and chemical products are currently manufactured. The maximum concentration of total suspended solids was detected at an area where textile, paper, plastic, chemical, and fabricated metal products are manufactured.

  2. The influence of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation

    Energy Technology Data Exchange (ETDEWEB)

    Putro, Triswantoro, E-mail: tris@physics.its.ac.id; Endarko, E-mail: endarko@physics.its.ac.id [Physics Department, Faculty of Mathematics and Natural Science Institut Teknologi Sepuluh Nopember (ITS), Surabaya 60111 (Indonesia)

    2016-04-19

    The influences of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation in water have been successfully investigated. The study used three pairs of magnetic field 0.1 T whilst the electron discharge was generated from television flyback transformer type BW00607 and stainless steel SUS 304 as an electrode. The water sample with an initial condition of 230 mg/L placed in the reactor with flow rate 375 mL/minutes, result showed that the electron discharge can be reduced contain of calcium carbonate the water sample around 17.39% within 2 hours. Meanwhile for the same long period of treatment and flow rate, around 56.69% from initial condition of 520 mg/L of calcium carbonate in the water sample can be achieved by three pairs of magnetic field 0.1 T. When the combination of three pairs of magnetic field 0.1 T and the electron discharge used for treatment, the result showed that the combination of electron discharge and magnetic field methods can be used to precipitate calcium carbonate in the water sample 300 mg/L around 76.66% for 2 hours of treatment. The study then investigated the influence of the polar position of the magnetic field on calcium carbonate precipitation. Two positions of magnetic field were tested namely the system with alternated polar magnetics and the system without inversion of the polar magnetics. The influence of the polar position showed that the percentage reduction in levels of calcium carbonate in the water sample (360 mg/L) is significant different. Result showed that the system without inversion of the polar magnetics is generally lower than the system with alternated polar magnetics, with reduction level at 30.55 and 57.69%, respectively.

  3. Climate Change on Discharge and Sedimentation of River Awara, Nigeria

    Directory of Open Access Journals (Sweden)

    Philipa O. Idogho

    2014-07-01

    Full Text Available The dynamics of variation in effect of climate change on discharges and sedimentation mechanism of River Awara is investigated using 14-year data of rainfall (mm, discharges (m 3 /s, temperature ( 0 c and sediment load (t. Surface runoff (mm was computed using Water Balance Equation and some other empirical iteration based on the observed rainfall and temperature over a period of time. Analysis of Paired Sample reveals the relationship between tested hydrological variables: Rainfall-Runoff; Runoff-Sediment load; and DischargeSediment load are significant at 0.95 level of confidence interval. Logarithm calibration curve further illustrates that Rainfall-Runoff and Runoff-Sediment have coefficient values (R 2 of 0.996 and 0.822 respectively. Analytical iteration shows that the intensity and duration of precipitation determine the magnitude of river, generation of surface runoff and sedimentation rate. Increase in rainfall depth by 100 mm within the 14-year has resulted to serious erodobility and erositivity around River Awara. Cumulative average sediment load ratio of 0.46 has significantly reduced the reservoir capacity of the river by 10%. 78% of total annual surface runoff is lost to ocean; since reservoir capacity has been silted up which in turns reduces the volume of water that could be held for storage, treatment and distribution for its intended purposes. Comparative physics-based output indicates that temperature increase of 0.7 0 c between 1997 and 2004, due to internal processes of the Earth and some human activities. It is however projected that temperature will rise by 0.9 0 c by the end of 2015. Projected rise in temperature will adversely affect hydrological cycle and complicate already scarce-water resources due to intensive evapotranspiration, infiltration and reduction in stream flow. Holistic integration using bottom-up mechanism needs to be applied to address this constraint. Dredging of river Awara is very important to enhance

  4. Explosive Processes on Cathode while Forming Nanosecond Pulsed Discharge of High Pressure

    Directory of Open Access Journals (Sweden)

    A. M. Hashimov

    2012-01-01

    Full Text Available The paper is devoted to research of cathode surfaces with different curvature radius (r = 1–8 mm while forming nanosecond pulsed discharge in dense air. Influence of field and air pressure heterogeneity rate in gas gap on size of micro-craters being formed on working cathode surface after pulsed effect has been shown in the paper. The paper reveals a maximum expansion of separate micro-crater size on cathode surface with small curvature radius.

  5. Singlet oxygen generation in O2 flow excited by RF discharge: I. Homogeneous discharge mode: α-mode

    International Nuclear Information System (INIS)

    Braginskiy, O V; Vasilieva, A N; Klopovskiy, K S; Kovalev, A S; Lopaev, D V; Proshina, O V; Rakhimova, T V; Rakhimov, A T

    2005-01-01

    The production and transport dynamics of O 2 (a 1 Δ g ) and O 2 (b 1 Σ g + ) molecules as well as O( 3 P) atoms has been studied in an O 2 flow excited by a 13.56 MHz RF discharge in a quartz tube at pressures of 1-20 Torr. It has been shown that the densities of O 2 (a 1 Δ g ) and O( 3 P) are saturated with increasing energy input into the discharge. The maximum yield of singlet oxygen (SO) and the O 2 dissociation degree drops with pressure. It is demonstrated that depending on the energy input the RF discharge can exist in three modes: I-in the spatially homogeneous mode or α-mode; III-in the substantially inhomogeneous mode, when plasma jets are present outside the discharge; and II-in the transient mode between modes I and III. In this paper only the homogeneous mode of RF discharge in the O 2 flow is considered in detail. A self-consistent model of the α-mode is developed, that allows us to analyse elementary processes responsible for the production and loss of O 2 (a 1 Δ g ) and O 2 (b 1 Σ g + ) molecules as well as O( 3 P) atoms in detail. To verify both the kinetic scheme of the model and the conclusions, some experiments have been carried out at lower flow velocities and higher pressures (≥10 Torr), when the stationary densities of O 2 (a 1 Δ g ), O 2 (b 1 Σ g + ) and O( 3 P) in the discharge area were established not by the escape of particles but by the losses due to the volumetric and surface reactions. The O 2 (b 1 Σ g + ) density under these conditions is determined by the balance of O 2 (b 1 Σ g + ) production by both direct electron impact and electronic excitation transfer from metastable O( 1 D) atoms and deactivation by oxygen atoms and tube walls, including quenching by ozone in the afterglow. The O( 3 P) density is determined by the balance between the production through O 2 dissociation by electron impact and heterogeneous loss at the wall recombination. The stationary density of O 2 (a 1 Δ g ) is provided by the processes of O

  6. Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage

    Science.gov (United States)

    Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN

    2018-05-01

    For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.

  7. Approximate maximum parsimony and ancestral maximum likelihood.

    Science.gov (United States)

    Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat

    2010-01-01

    We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.

  8. State waste discharge permit application: 200 Area Treated Effluent Disposal Facility (Project W-049H)

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    As part of the original Hanford Federal Facility Agreement and Concent Order negotiations, US DOE, US EPA and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground to the Hanford Site are subject to permitting in the State Waste Discharge Permit Program (SWDP). This document constitutes the SWDP Application for the 200 Area TEDF stream which includes the following streams discharged into the area: Plutonium Finishing Plant waste water; 222-S laboratory Complex waste water; T Plant waste water; 284-W Power Plant waste water; PUREX chemical Sewer; B Plant chemical sewer, process condensate, steam condensate; 242-A-81 Water Services waste water.

  9. State waste discharge permit application: 200 Area Treated Effluent Disposal Facility (Project W-049H)

    International Nuclear Information System (INIS)

    1994-08-01

    As part of the original Hanford Federal Facility Agreement and Concent Order negotiations, US DOE, US EPA and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground to the Hanford Site are subject to permitting in the State Waste Discharge Permit Program (SWDP). This document constitutes the SWDP Application for the 200 Area TEDF stream which includes the following streams discharged into the area: Plutonium Finishing Plant waste water; 222-S laboratory Complex waste water; T Plant waste water; 284-W Power Plant waste water; PUREX chemical Sewer; B Plant chemical sewer, process condensate, steam condensate; 242-A-81 Water Services waste water

  10. Comparison of trace metals in intake and discharge waters of power plants using clean techniques

    International Nuclear Information System (INIS)

    Salvito, D.T.; Allen, H.E.

    1995-01-01

    In order to determine the impact to receiving waters of trace metals potentially discharged from a once-through, non-contact cooling water system from a power plant, a study was conducted utilizing clean sampling and analytical techniques for a series of metals. Once-through, non-contact cooling water at power plants is frequently discharged back to the fresh or saline waterbody utilized for its intake water. This water is used to cool plant condensers. Intake and discharge data were collected and evaluated using paired t-tests. Study results indicate that there is no measurable contribution of metals from non-contact cooling water from this power plant

  11. Reconstructing the history of 14C discharges from Sellafield. Part 2. Aquatic discharges

    International Nuclear Information System (INIS)

    Cook, G.T.; MacKenzie, A.B.; Naysmith, F.H.; Anderson, R.; Naysmith, P.; Kershaw, P.J.

    2004-01-01

    Prior to 1984, the reported marine 14 C discharges from Sellafield were estimates: 0.2 TBq per annum from 1952 to 1969 and 1 TBq per annum until 1984 when measurements commenced. The relationship between the net excess 14 C activity in annually collected Nori (Porphyra umbilicalis) seaweed samples and the annual discharges (estimated and measured) implies that the discharges were not as constant as the estimates. Based on the relationship between post-1984 measured discharges and the excess 14 C in the seaweed, two simple empirical models were used to re-calculate the discharges between 1967 and 1984. Gamma-spectrometry measurements on the seaweed also indicate that Porphyra is a sensitive indicator of changes in discharge of other radionuclides, brought about by the introduction of new waste clean-up technologies within Sellafield. (author)

  12. The last glacial maximum

    Science.gov (United States)

    Clark, P.U.; Dyke, A.S.; Shakun, J.D.; Carlson, A.E.; Clark, J.; Wohlfarth, B.; Mitrovica, J.X.; Hostetler, S.W.; McCabe, A.M.

    2009-01-01

    We used 5704 14C, 10Be, and 3He ages that span the interval from 10,000 to 50,000 years ago (10 to 50 ka) to constrain the timing of the Last Glacial Maximum (LGM) in terms of global ice-sheet and mountain-glacier extent. Growth of the ice sheets to their maximum positions occurred between 33.0 and 26.5 ka in response to climate forcing from decreases in northern summer insolation, tropical Pacific sea surface temperatures, and atmospheric CO2. Nearly all ice sheets were at their LGM positions from 26.5 ka to 19 to 20 ka, corresponding to minima in these forcings. The onset of Northern Hemisphere deglaciation 19 to 20 ka was induced by an increase in northern summer insolation, providing the source for an abrupt rise in sea level. The onset of deglaciation of the West Antarctic Ice Sheet occurred between 14 and 15 ka, consistent with evidence that this was the primary source for an abrupt rise in sea level ???14.5 ka.

  13. NIPPLE DISCHARGE

    Directory of Open Access Journals (Sweden)

    T. N. Bukharova

    2008-01-01

    Full Text Available According to the data available in the literature, as high as 50% of women have benign breast tumors frequently accompanied by nip- ple discharge. Nipple discharge may be serous, bloody, purulent, and colostric. The most common causes are breast abscess, injury, drugs, prolactinoma, intraductal pappiloma, ductal ectasia, intraductal cancer (not more than 10%.

  14. How could discharge management affect Florida spring fish assemblage structure?

    Science.gov (United States)

    Work, Kirsten; Codner, Keneil; Gibbs, Melissa

    2017-08-01

    Freshwater bodies are increasingly affected by reductions in water quantity and quality and by invasions of exotic species. To protect water quantity and maintain the ecological integrity of many water bodies in central Florida, a program of adopting Minimum Flows and Levels (MFLs) has begun for both lentic and lotic waters. The purpose of this study was to determine whether there were relationships between discharge and stage, water quality, and biological parameters for Volusia Blue Spring, a first magnitude spring (discharge > 380,000 m 3 day -1 or 100 mgd) for which an MFL program was adopted in 2006. Over the course of fourteen years, we assessed fish density and diversity weekly, monthly, or seasonally with seine and snorkel counts. We evaluated annual changes in the assemblages for relationships with water quantity and quality. Low discharge and dissolved oxygen combined with high stage and conductivity produced a fish population with a lower density and diversity in 2014 than in previous years. Densities of fish taxonomic/functional groups also were low in 2014 and measures of water quantity were significant predictors of fish assemblage structure. As a result of the strong relationships between variation in discharge and an array of chemical and biological characteristics of the spring, we conclude that maintaining the historical discharge rate is important for preserving the ecological integrity of Volusia Blue Spring. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Two-Dimensional Simulation of Spatial-Temporal Behaviors About Period Doubling Bifurcation in an Atmospheric-Pressure Dielectric Barrier Discharge

    International Nuclear Information System (INIS)

    Zhang Jiao; Wang Yanhui; Wang Dezhen; Zhuang Juan

    2014-01-01

    As a spatially extended dissipated system, atmospheric-pressure dielectric barrier discharges (DBDs) could in principle possess complex nonlinear behaviors. In order to improve the stability and uniformity of atmospheric-pressure dielectric barrier discharges, studies on temporal behaviors and radial structure of discharges with strong nonlinear behaviors under different controlling parameters are much desirable. In this paper, a two-dimensional fluid model is developed to simulate the radial discharge structure of period-doubling bifurcation, chaos, and inverse period-doubling bifurcation in an atmospheric-pressure DBD. The results show that the period-2n (n = 1, 2…) and chaotic discharges exhibit nonuniform discharge structure. In period-2n or chaos, not only the shape of current pulses doesn't remains exactly the same from one cycle to another, but also the radial structures, such as discharge spatial evolution process and the strongest breakdown region, are different in each neighboring discharge event. Current-voltage characteristics of the discharge system are studied for further understanding of the radial structure. (low temperature plasma)

  16. Edge localized modes and edge pedestal in NBI and ICRF heated H, D and T-plasmas in JET

    International Nuclear Information System (INIS)

    Bhatnagar, V.; Lingertat, J.; Barnsley, R.

    1998-12-01

    Based on experiments carried out in JET in D:T mixtures varying from 100:0 to 5:95 and those carried out in hydrogen plasmas, the isotopic mass dependence of ELM parameters and the edge pedestal pressure in neutral beam (NBI) and ion cyclotron resonance (ICRF) heated H-mode plasmas is presented. The ELM frequency is found to decrease with the atomic mass number both in ICRH and NBI discharges. However, the frequency in the case of ICRH is about 8 - 10 times higher than in the NBI case. Assuming that ELMs occur at a critical edge pressure gradient, limited by the ballooning instability, the scaling of the maximum edge pressure is most consistent with the assumption that the width of the transport barrier scales as the ion poloidal Larmor radius governed by the average energy of fast ions at the edge. The critical edge pressure in NBI heated discharges increases with the isotopic mass which. is consistent with the higher deduced width of the edge transport, barrier in tritium than in deuterium and hydrogen. The critical edge pressure in ICRH discharges is smaller, presumably, due to the smaller fast-ion contribution to the edge region. As a consequence of the edge pressure scaling with isotopic mass, the edge operational space in the n e - T e diagram increases with operation in tritium. If the evidence that the edge pedestal width is governed by the average energy of fast ions in the edge prevails, the pedestal in ITER would be controlled by the slowing down energy spectrum of α-particles in the edge. (author)

  17. Role of secondary emission on discharge dynamics in an atmospheric pressure dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Tay, W. H.; Kausik, S. S.; Yap, S. L.; Wong, C. S., E-mail: cswong@um.edu.my [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-04-15

    The discharge dynamics in an atmospheric pressure dielectric barrier discharge (DBD) is studied in a DBD reactor consisting of a pair of stainless steel parallel plate electrodes. The DBD discharge has been generated by a 50 Hz ac high voltage power source. The high-speed intensified charge coupled device camera is used to capture the images of filaments occurring in the discharge gap. It is observed that frequent synchronous breakdown of micro discharges occurs across the discharge gap in the case of negative current pulse. The experimental results reveal that secondary emissions from the dielectric surface play a key role in the synchronous breakdown of plasma filaments.

  18. Metal discharges by Sinaloa Rivers to the coastal zone of NW Mexico.

    Science.gov (United States)

    Frías-Espericueta, M G; Mejía-Cruz, R; Osuna López, I; Muy-Rangel, M D; Rubio-Carrasco, W; Aguilar-Juárez, M; Voltolina, D

    2014-02-01

    The aim of this work was to survey the discharges of dissolved and particulate Cd, Cu, Fe, Mn, Pb and Zn of the eight main rivers of Sinaloa State to the Mexican coastal environment. Zn was the most abundant dissolved metal and Fe was the most abundant particulate (8.02-16.90 and 51.8-1,140.3 μg/L, respectively). Only particulate Mn had significantly (p = 0.028) higher values in summer-fall (rainy season), whereas the significantly (p = 0.036) higher values of dissolved Zn were observed in winter and spring. The highest annual total discharges to Sinaloa coastal waters were those of the rivers San Lorenzo and Piaxtla (>2 × 10(3) m.t.) and the lowest those of rivers Baluarte and El Fuerte (349 and 119 m.t., respectively). Pb concentrations may become of concern, because they are higher than the value recommended for the welfare of aquatic communities of natural waters.

  19. The critical role of the routing scheme in simulating peak river discharge in global hydrological models

    Science.gov (United States)

    Zhao, F.; Veldkamp, T.; Frieler, K.; Schewe, J.; Ostberg, S.; Willner, S. N.; Schauberger, B.; Gosling, S.; Mueller Schmied, H.; Portmann, F. T.; Leng, G.; Huang, M.; Liu, X.; Tang, Q.; Hanasaki, N.; Biemans, H.; Gerten, D.; Satoh, Y.; Pokhrel, Y. N.; Stacke, T.; Ciais, P.; Chang, J.; Ducharne, A.; Guimberteau, M.; Wada, Y.; Kim, H.; Yamazaki, D.

    2017-12-01

    Global hydrological models (GHMs) have been applied to assess global flood hazards, but their capacity to capture the timing and amplitude of peak river discharge—which is crucial in flood simulations—has traditionally not been the focus of examination. Here we evaluate to what degree the choice of river routing scheme affects simulations of peak discharge and may help to provide better agreement with observations. To this end we use runoff and discharge simulations of nine GHMs forced by observational climate data (1971-2010) within the ISIMIP2a project. The runoff simulations were used as input for the global river routing model CaMa-Flood. The simulated daily discharge was compared to the discharge generated by each GHM using its native river routing scheme. For each GHM both versions of simulated discharge were compared to monthly and daily discharge observations from 1701 GRDC stations as a benchmark. CaMa-Flood routing shows a general reduction of peak river discharge and a delay of about two to three weeks in its occurrence, likely induced by the buffering capacity of floodplain reservoirs. For a majority of river basins, discharge produced by CaMa-Flood resulted in a better agreement with observations. In particular, maximum daily discharge was adjusted, with a multi-model averaged reduction in bias over about 2/3 of the analysed basin area. The increase in agreement was obtained in both managed and near-natural basins. Overall, this study demonstrates the importance of routing scheme choice in peak discharge simulation, where CaMa-Flood routing accounts for floodplain storage and backwater effects that are not represented in most GHMs. Our study provides important hints that an explicit parameterisation of these processes may be essential in future impact studies.

  20. H-mode-like discharge under the presence of 1/1 rational surface at ergodic layer in LHD

    International Nuclear Information System (INIS)

    Morita, Shigeru; Morisaki, Tomohiro; Tanaka, Kenji

    2004-01-01

    H-mode-like discharge was found in LHD with a full B t field of 2.5T at an outwardly shifted configuration of R ax = 4.00 m where the m/n = 1/1 rational surface is located at the ergodic layer. The H-mode-like discharge was triggered by changing the P NBI from 9MW to 5 MW in a density range of 4-8 x 10 13 cm -3 , followed by a clear density rise, ELM-like H α bursts, and a reduction of magnetic fluctuation. These H-mode-like features vanished with a small radial movement of the 1/1 surface. (author)