  1. An algorithm for applying flagged Sysmex XE-2100 absolute neutrophil counts in clinical practice

    DEFF Research Database (Denmark)

    Friis-Hansen, Lennart; Saelsen, Lone; Abildstrøm, Steen Z

    2008-01-01

    therefore examined if an algorithm could be developed to identify samples in which the automated ANC is valid despite flagged test results. METHODS: During a 3-wk period, a training set consisting of 1448 consecutive flagged test-results from the Sysmex XE-2100 system and associated manual differential....... CONCLUSION: We have developed a simple algorithm that identifies samples from which a valid ANC can be extracted from Sysmex XE-2100 flagged differential counts. In patients where only ANC is required for treatment purposes, this procedure can greatly shorten turn around time and facilitate rapid decision...

  2. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  3. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients

    Directory of Open Access Journals (Sweden)

    Tina Dadu

    2013-01-01

    Full Text Available Background: There are several methods for counting platelets, of which the international flow reference method (IRM is considered to be the gold standard. We compared the platelet count given by this method to the count given by automated analyzers using other methods, such as optical fluorescence and impedance. Aims: The aim of this study is to compare the platelet counts obtained by Sysmex XE 2100 by Impedance (Sysmex-I, optical florescence (Sysmex-O and reported (Sysmex-R based on the switching algorithm and LH-750 by Impedance (LH-750 with the IRM in thrombocytopenic blood samples. To calculate the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of various technologies at the clinically relevant transfusion thresholds of 10 × 10 9 /l and 20 × 10 9 /l. Materials and Methods: A total of 118 blood samples with platelet count of <50 × 10 9 /l were selected for the study. Platelet counts of all samples were analyzed by all methods using the Sysmex analyzer, LH-750 and IRM in parallel within 6 h of collection. Statistical Analysis Used: Pearson correlation, bland Altman analysis, sensitivity and specificity, PPV and NPV. Results and Conclusions: Sysmex-R had the least Bias and 95% limits of agreement (95%LA range and thus correlated best with IRM values. LH-750 had a higher Bias compared to Sysmex-O and Sysmex-R, but a strikingly similar 95% LA ensures similar results in all three methods. In fact, in the oncology subset, it had the narrowest 95% LA, which made it the best performer in this subgroup. Of the three Sysmex results, Sysmex-I had the highest bias, widest 95% LA and highest potential risk of over transfusion. Hence, Sysmex-R and LH-750 were found to be reliable tools for estimation of platelet count in thrombocytopenic patients.

  4. Reference range evaluation of complete blood count parameters with emphasis on newer research parameters on the complete blood count analyzer Sysmex XE-2100

    Directory of Open Access Journals (Sweden)

    Kunal K Sehgal

    2013-01-01

    Full Text Available Since the advent of automation in the field of hematological cell counters there has been a constant refinement of the technology and increase in the number of newer parameters available on CBC analysers. Many novel parameters are being put into routine clinical use and both clinical evaluation and monitoring critically depend on knowledge of laboratory reference ranges. Here, we present reference interval for the Sysmex XE-2100, with emphasis on the novel or newer research parameters. Blood samples from a total of 122 clinically asymptomatic and apparently healthy subjects were evaluated and a final of 100 subjects (54-M, 46-F were included in the study. A broad spectrum of parameters available with the analyser was assessed and reference ranges for the same evaluated.

  5. From XE-2100 to XN-9000, from SIS Standard to GFHC recommendations for slide review: potential impact on review rate and turnaround time.

    Science.gov (United States)

    Tamigniau, Anne; Bailly, Nicolas; Chatelain, Bernard; Mullier, François

    2017-06-01

    In 2014, we moved from XE-2100 with Standard SIS rules to XN-9000 with GFHC recommendations for slide review. The aim of our study was to evaluate the potential impact of the new Sysmex ® automation with implementation of GFHC rules on our review rate, turnaround time (TAT), workload and on CD34+ stem cells enumeration. We conducted a retrospective observational study from September 2013 through August 2014, in CHU Dinant Godinne UCL Namur. With the GFHC recommendations and the new Sysmex ® automation, we significantly reduced our review rate by nearly 30% considering all units (35.8% vs 25.9%), and up to 73% when excluding oncology haematology department (17.5% vs 4.7%). We also noticed significantly shorter TAT for CBC measurement (median for routine samples: 76.4 vs 56.8 minutes, p < 0.0001; urgent samples: 18.9 vs 15.2 minutes, p = 0.023), slide review (median: 54.9 vs 36.4 minutes, p < 0.0001) and CD34+ enumeration performed on peripheral blood samples (p < 0.001) and on apheresis samples (p = 0.026). In conclusion, GFHC recommendations implemented on the new Sysmex ® XN-9000 resulted in a significant reduction in review rate and in TAT. This is particularly of interest for the clinicians with subsequent potential faster patient management.

  6. Hypo- and hypernatremia results in inaccurate erythrocyte mean corpuscular volume measurement in vitro, when using Sysmex XE 2100

    DEFF Research Database (Denmark)

    Phillipsen, Jens Peter; Madsen, Kirsten Vikkelsø

    2015-01-01

    INTRODUCTION: Automated hematology analyzers dilute patient erythrocytes with an isoosmotic diluent before quantitating the erythrocyte mean cell volume (MCV). However, if patient plasma osmolality differs from the diluent, water will cross the erythrocytes membrane and establish a new equilibrium...... resulted in inaccurate MCV. The experimental results also revealed a strong correlation between P-Osmolality/P-Sodium and MCV inaccuracy (R2 = 0.70/0.85) similar to the theoretically calculated MCV inaccuracy. We suggest using mean cellular Hb (MCH) instead of MCV, mean corpuscular Hb concentration (MCHC...

  7. Hypo - and hypernatremia results in inaccurate Erythrocytes mean Corpuscular Volume (MCV) measurement in vitro, when using Sysmex XE 2100

    DEFF Research Database (Denmark)

    Madsen, Kirsten Vikkelsø; Philipsen, Jens Peter

    Introduction: Automated hematology analyzers dilute patient erythrocytes with an isosmotic diluent before quantitating the erythrocyte Mean Cell Volume (MCV). However, if patient plasma osmolality differs from the diluent, water will cross the erythrocytes membrane and establish a new equilibrium...

  8. Reference intervals for absolute and percentage immature platelet fraction using the Sysmex XN-10 automated haematology analyser in a UK population.

    Science.gov (United States)

    Ali, Usman; Knight, Gavin; Gibbs, Roz; Tsitsikas, Dimitris A

    2017-12-01

    Immature platelet fraction (IPF) estimation is a non-invasive and sensitive test that is available on recently introduced Sysmex XN-series of automated haematology analysers. It is a direct cellular indicator of thrombopoiesis. The aim of this study was to establish reference intervals for IPF, for both absolute (A-IPF) and percentage (%-IPF) measurements. A total of 2366 samples that met the inclusion criteria were assayed for full blood count on the Sysmex XN-10 and a non-parametric percentile method was used for calculating the reference intervals. After the outliers were excluded, the reference interval for %-IPF and A-IPF on Sysmex XN-10 were 1.6-10.1% and 4.37-23.21 × 10 9 /L in total individuals, respectively. There was a statistical significance noted between the sexes (p = .004) for %-IPF, therefore a sex-specific reference interval was established, which was 1.8-10.0% for the males and 1.5-10.1% for females. No significant difference in sex status for A-IPF and age status for both %-IPF and A-IPF was observed. A very poor correlation was estimated between age versus %-IPF, ρ = 0.0156, and age versus A-IPF, ρ = -0.0023, indicating that there is no overall biological relationship between age and these parameters. As expected, a strong correlation between %-IPF and A-IPF was noted which could be attributed to their inter-relatedness. This large-scale study showed comparable reference intervals with the previous studies for %-IPF and A-IPF in a UK population. It found the need to establish sex-specific reference intervals for %-IPF, but not for A-IPF, whereas reference intervals were found to be stable across the age range.

  9. Comparison of white blood cell counts by WNR, WDF, and WPC channels in Sysmex XN hematology analyzer.

    Science.gov (United States)

    Kim, H; Hur, M; Choi, S-G; Oh, K-M; Moon, H-W; Yun, Y-M

    2015-12-01

    The Sysmex XN modular system (Sysmex, Kobe, Japan) uses a novel technology for white blood cell (WBC) count and differential, using separate channels: white cell nucleated (WNR), WBC differential (WDF), and white progenitor cell (WPC) channels. We questioned how concordant WBC counts would be between them. In a total of 6327 consecutive specimens, WBC counts were compared between WNR and WDF channels. They were also compared in three groups of WBC counts and two groups of chemotherapy status. In 508 specimens from the 4361 specimens that were run on the XN-20 module, the WPC channel was used for reflex test. Data were compared using Pearson's correlation, absolute difference, and percent difference (%D). WBC counts between WNR and WDF channels showed very high correlations in total specimens (r = 0.9976) and in the groups of WBC counts and chemotherapy. As WBC count increased, absolute difference increased, while %D decreased (P WPC channels are highly correlated, and they are overall interchangeable and reliable. © 2015 John Wiley & Sons Ltd.

  10. AutomatedPlasmodiumdetection by the Sysmex XN hematology analyzer.

    Science.gov (United States)

    Dumas, Cécile; Bienvenu, Anne-Lise; Girard, Sandrine; Picot, Stéphane; Debize, Gisèle; Durand, Brigitte

    2018-01-03

    Malaria is a potentially severe disease affecting nearly 200 million people per year. Early detection of the parasite even in unsuspected patients remains the challenging aim for effective patient care. Automated complete blood counts that are usually performed for any febrile patient might represent a tool to ascertain malaria infection. To evaluate the ability of the new generation of the Sysmex hematology analyzer (XN-series) to detect malaria. We retrospectively studied 100 blood samples performed with the recent Sysmex XN analyzer that were positive for Plasmodium and explored its ability to detect the parasite. 100 samples from patients uninfected by malaria were used as control group. Specific abnormalities such as additional events in the mature neutrophil/eosinophil area of the white blood cells differential (WDF) scattergram were noted for 1.1% of Plasmodium falciparum samples and 56.2% of other Plasmodium species samples. Mature parasite stages (schizonts or gametocytes) were observed on blood smears among those samples. WDF scattergrams were able to detect 80.0% (12/15) of Plasmodium mature stages. Furthermore, the differential in white blood counts between WDF and white cell nucleated (WNR) channels was a predictive signal of Plasmodium mature stages in 73.3% (11/15) of samples and may be explained by a differential destruction of particles with the analyzer reagent. Associated to thrombocytopaenia, a Sysmex XN Plasmodium pattern may represent a useful warning for Plasmodium detection in unsuspected patients, particularly when mature parasite stages are present. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Evaluation of a new automated cell analyzer (Sysmex UF-1000i for bacteriological screening of urine

    Directory of Open Access Journals (Sweden)

    Shanti Levi

    2012-12-01

    Full Text Available Introduction. Sysmex UF-1000 is a new flow cytometry for the analysis of urine based on a laser diode technology using specific compounds for the staining nucleic acids, characterized by a threshold of detection of bacteria equal to 1000 CFU/ml.The purpose of this study was to compare the positivity or negativity of the urine samples using standard procedures and with the response obtained from the instrument UF-1000i. Methods. During the period May and July 2011, 1024 urine samples obtained from the laboratory of the hospital in Genoa-Voltri were analyzed with the instrument Sysmex UF-1000i.The samples were stored at a temperature of 5°C during transport.The instrument after loading of the sample is able to assess the bacterial load in about 1 minute per sample. Results. 1024 samples were analyzed with Sysmex UF-1000 analyzed in parallel by the hospital laboratory in Genoa Voltri. 228 are positive results for Sysmex UF-1000 (bacterial loads in excess of 1000 CFU/ml.The data obtained were consistent with those recorded with traditional analysis. 18 samples were positive only for our instrument, but not with the traditional system used in the laboratory for comparison. Conclusion. The advantage of Sysmex UF-1000 is certainly due to obtain immediate results after the reading of each individual sample that is higher than any other instrument or method of analysis used. The slight discrepancy of the results obtained may be due to the extremely low calibration of UF-1000. This allows in a very short time to discard all negative samples with enormous saving of time and material. For positive samples and applies the criterion of the routine ie, the bacterial load has a meaning according to the type of patient considered, as in the case of pediatric or catheterized patients

  12. Validation of the Sysmex sp-1000i automated slide preparer-stainer in a clinical laboratory

    Directory of Open Access Journals (Sweden)

    Eberson Damiao dos Santos de Bitencourt

    2013-01-01

    Full Text Available Background: The speed and quality of information have become essential items in the release of laboratory reports. The Sysmex®SP1000-I device has been developed to prepare and stain smear slides. However, for a device to be cleared for use in the laboratory routine it must pass through a validation process. Objective: To evaluate the performance and reliability of the Sysmex® SP-1000i slide preparer-stainer incorporated into the routine of a hospital laboratory in Porto Alegre. Methods: Peripheral blood samples of patients attending the laboratory for ambulatory exams with leukocyte counts between 7000/°L and 12,000/°L were evaluated, independent of gender and age. Two slides were prepared for each sample using the Sysmex® SP-1000i equipment; one of the slides was used to perform quality control tests using the CellaVision® DM96 device, and the other slide was used to compare pre-classification by the same device and the classification performed by a pharmacist-biochemist. Results: The results of all the slides used as controls were acceptable according to the quality control test as established by the manufacturer of the device. In the comparison between the automated pre-classification and the classification made by the professional, there was an acceptable variation in the differential counts of leukocytes for 90% of the analyzed slides. Pearson correlation coefficient showed a strong correlation for band neutrophils (r = 0.802; p-value < 0.001, segmented neutrophils (r = 0.963; p-value < 0.001, eosinophils (r = 0.958; p-value < 0.001, lymphocytes (r = 0.985; p-value < 0.001 and atypical lymphocytes (r = 0.866; p-value < 0.001 using both methods. The red blood cell analysis was adequate for all slides analyzed by the equipment and by the professional. Conclusion: The new Sysmex®SP1000-i methodology was found to be reliable, fast and safe for the routines of medium and large laboratories, improving the quality of microscopic analysis in

  13. Performance Assessment of Sysmex® CA-104 for Screening Coagulogram Testing

    Directory of Open Access Journals (Sweden)

    Oranut Komkhum

    2016-01-01

    Full Text Available Objective: The Sysmex® CA-104 (CA-104 is a new, semi-automated coagulation analyzer which has not yet been evaluated in Thailand. The objective of this study was to evaluate the CA-104 performance for prothrombin time (PT, activated partial thromboplastin time (APTT, and international normalized ratio (INR under local laboratory conditions. Methods: Real patient samples and control materials were used to evaluate CA-104 in terms of precision, reference range, and comparability to the validated Sysmex® CS-2100i analyzer (CS-2100i. Results: The highest percentages of coefficient of variation of PT and APTT were 1.34 and 1.47 for within-run, and 3.2 and 1.65 for between-run precision studies. Correlation coefficients of PT, APTT, and INR between CA-104 and CS-2100i were 0.97, 0.95, and 0.99, respectively. Mean biases of PT, APTT, and INR of CA-104 compared with those from CS-2100i were low. Most results were within 95% agreement, although a few values at the high levels were not. For INR testing, no specimen required warfarin dose adjustment when using CA-104 instead of CS-2100i. Conclusion: Performance of CA-104 for screening coagulogram in terms of precision and comparability to CS-2100i was acceptable. However, a few discrepancies in clotting time at high values were observed. Further investigation to identify the cause of this discrepancy is warranted.

  14. [Experimental evaluation of the Sysmex UF-1000i for ruling out non-gonococcal urethritis].

    Science.gov (United States)

    Grosso, Shamanta; Bruschetta, Graziano; Camporese, Alessandro

    2012-09-01

    Acute nongonococcal urethritis (NGU) is one of the commonest sexually transmitted infections affecting men and women. The diagnosis of NGU has traditionally required microscopic evidence of urethritis. However, a significant proportion of patients with urethral symptoms do not have microscopic evidence of urethritis. The purpose of the present study was to evaluate the analytical performance of the UF1000i, a recently introduced fluorescence flow cytometer intended for urinalysis purposes which provides new analytical features that seem particularly suitable for microbiological diagnostics, for ruling out NGU or predicting the presence of infection. The Sysmex UF1000i is a flow cytometry analyzer capable of quantifying a lot of particles, including bacteria (BACT) and white blood cells (WBCs). To evaluate the analytical performance of the UF1000i as a method for ruling out NGU, we examined 200 urethral smear samples, collected in a new liquid transport medium (Copan), and compared the UF1000i results with standard culture/molecular and microscopic Gram stain results. With instrument cut-off values of 200 BACT x 10^6/L and 500 WBCs x 10^6/L, we obtained a sensitivity of 84%, a specificity of 82%, and a high negative predictive value (96%). Culture/molecular detection of pathogens remains the gold standard technique for the diagnosis of NGU. However, the Sysmex UF1000i is capable of improving the efficiency of NGU presumptive diagnosis, providing results in a few minutes, with a high negative predictive value and high values of sensitivity.

  15. Hemopoietic stem and precursor cell analysis in umbilical cord blood using the Sysmex SE-9000 IMI channel.

    NARCIS (Netherlands)

    Kraai, R.; Reymer, A.G.; Brouwer-Mandema, G.G.; Beckhoven, J.M. van; Hoogeboom, M.; Cessie, S. le; Kluin-Nelemans, H.C.

    2001-01-01

    Circulating hematopoietic progenitor cells (HPCs) are routinely measured by flow cytometry using CD34 expression. As an alternative, the "immature information" (IMI) channel measurement of the automated hematology analyzer Sysmex SE machines was developed. We tested the IMI channel HPC method with

  16. Hemopoietic stem and precursor cell analysis in umbilical cord blood using the Sysmex SE-9000 IMI channel

    NARCIS (Netherlands)

    Kraai, R; Reymer, AGF; Brouwer-Mandema, GG; van Beckhoven, JM; Hoogeboom, M; le Cessie, S; Kluin-Nelemans, J.C.

    2001-01-01

    Circulating hematopoietic progenitor cells (HPCs) are routinely measured by flow cytometry using CD34 expression. As an alternative, the "immature information" (IMI) channel measurement of the automated hematology analyzer Sysmex SE machines was developed. We tested the IMI channel HPC method with

  17. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  18. New parameters available on Sysmex XE-5000 hematology analyzers contribute to differentiating dengue from leptospirosis and enteric fever.

    Science.gov (United States)

    Oehadian, A; Michels, M; de Mast, Q; Prihatni, D; Puspita, M; Hartantri, Y; Sinarta, S; van der Ven, A J A M; Alisjahbana, B

    2015-12-01

    Distinguishing dengue virus infection from other febrile thrombocytopenic illnesses such as leptospirosis or enteric fever is important but difficult, due to the unavailability of reliable diagnostic tests. Sysmex XE-5000 hematology analyzers use fluorescence flow cytometry to quantitate new parameters including cells in the atypical lymphocyte area (AL), high-fluorescent lymphocyte counts (HFLC), immature granulocytes (IG), and immature platelets (IPF). This study aimed to investigate whether these parameters can help to discriminate between the diseases. We compared hematocytometry performed by a Sysmex XE-5000 analyzer in Indonesian adults with dengue (n = 93), leptospirosis (n = 11), and enteric fever (n = 6) infection, and in healthy controls (n = 28). Receiver operating characteristic curves comparing dengue and leptospirosis showed that dengue was characterized by increased %AL (AUC 0.87; 95% CI 0.70-1.03), %HFLC (AUC 0.89; 95% CI 0.78-0.99), and %IPF (AUC 0.81; 95% CI 0.65-0.97), while patients with leptospirosis had increased %IG (AUC 0.86; 95% CI 0.71-1.02). Low %AL, %HFLC, and %IG supported a diagnosis of enteric fever. The detection of AL, HFLC, IG, and IPF by Sysmex XE-5000 hematology analyzers can help to differentiate between common causes of febrile illnesses with thrombocytopenia in dengue endemic areas. We recommend further investigating the discriminatory value of these parameters in clinical practice. © 2015 John Wiley & Sons Ltd.

  19. Diagnostic efficiency of the Sysmex XN WPC channel for the reduction of blood smears.

    Science.gov (United States)

    Noordegraaf, Madelon; Meijer, Paul; Ruinemans-Koerts, Janneke

    2016-11-01

    Several small studies showed that the WPC (white precursor cell) channel in the Sysmex haematology analyser for leukocyte differentiation analysis leads to a significant reduction of microscopic blood smears. We determined the added value of the WPC channel for blood smear reduction in a large teaching hospital and whether this reduction was cost-effective and save. Retrospectively, for 7850 leukocyte differentiation orders the percentage of samples resulting in a WPC analysis and the outcomes of the WPC analysis were analysed and compared with the blood smear results. WPC analysis resulted in a 12% reduction of blood smears, which is much lower than observed in other studies. This means 3-4bloodsmears/day less of a total of 28smears/day at the expense of missing 14 patient samples with pathology (blasts or abnormal lymphocytes) in a 9weeks period. The estimated total costs of WPC analysis per year was more than the reduction in costs due to less blood smear reviews. In a large teaching hospital, the small reduction in blood smears by the WPC channel does not outweigh the costs and the slight reduction in sensitivity for pathology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Biological variation of platelet parameters determined by the Sysmex XN hematology analyzer.

    Science.gov (United States)

    Buoro, Sabrina; Seghezzi, Michela; Manenti, Barbara; Pacioni, Aurelio; Carobene, Anna; Ceriotti, Ferruccio; Ottomano, Cosimo; Lippi, Giuseppe

    2017-07-01

    This study was aimed to define the short- and medium-term biological variation (BV) estimates, the index of individuality and the reference change value (RCV) of platelet count, platelet distribution width, mean platelet volume, platelet larger cell ratio, plateletcrit and immature platelet fraction. The study population consisted of 43 health subjects, who participated to the assessment of medium-term (21 subjects; blood sampling once a week for 5 consecutive weeks) and short-term (22 subjects; blood sampling once a day for 5 consecutive days) BV study, using Sysmex XN-module. Eight subjects were also scheduled to participate to both phases. The data were subject to outlier analysis prior to CV-ANOVA, to determine the BV estimates with the relative confidence intervals. The medium-term and short-term within-subject BV (CV I ) was comprised between 2.3 and 7.0% and 1.1-8.6%, whereas the medium-term and short-term between-subjects BV (CV G ) was comprised between 7.1 and 20.7% and 6.8-48.6%. The index of individuality and index of heterogeneity were always respectively 0.63 for all the parameters, in both arms of the study. The RCVs were similar for all parameters, in both arms of the study. This study allowed to define the BV estimates of many platelet parameters, some of them unavailable in literature. The kinetics of platelet turnover suggests the use of short-term BV data for calculating analytical goals and RCV. The correct clinical interpretation of platelet parameters also necessitates that each laboratory estimates local RCV values. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Performance evaluation of the Sysmex XE-5000 hematology analyzer for white blood cell analysis in cerebrospinal fluid.

    Science.gov (United States)

    Perné, Andrea; Hainfellner, Johannes A; Womastek, Irene; Haushofer, Alexander; Szekeres, Thomas; Schwarzinger, Ilse

    2012-02-01

    The newest generation hematology analyzer, Sysmex XE-5000 (Sysmex Corporation, Kobe, Japan) is equipped with an improved body fluid analysis mode. To evaluate the applicability of the XE-5000 analyzer to white blood cell (WBC) analysis in cerebrospinal fluid (CSF). A total of 425 routinely collected, consecutive CSF samples were included in the study. For a comparison of total WBC counts, the results of routine chamber counts were grouped into categories of 0 to 5 (n  =  330), >5 to 10 (n  =  36), >10 to 50 (n  =  39), >50 to 200 (n  =  15), and >200 (n  =  5) WBC/µL. Microscopic differential counts were performed using cytospins from 276 samples. Results were grouped according to the percent content of polymorphonuclear (PMN) cells, 0% to 25% (n  =  263), >25% to 50% (n  =  7), >50% to 75% (n  =  3), and >75% to 100% (n  =  3) of WBC. Corresponding results of XE-5000 analysis were matched to these particular count categories. For total WBC counts, the proportions of samples correctly classified by the XE-5000 from the percentage groups described above were 88%, 47%, 72%, 93%, and 100%, respectively. After the two lowest count categories were combined into one range of 0 to 10 WBC/µL, matches increased to 95%. For PMN counts in the 0% to 25% group, 37% of samples were misclassified by the XE-5000. Conversely, for samples with microscopic PMN counts of more than 25%, there was a trend toward underestimation by the XE-5000. Mismatches were most pronounced in samples with fewer than 10 WBC/µL. The Sysmex XE-5000 hematology analyzer yields valid total CSF cell counts and may be considered an acceptable alternative to the traditional chamber method, even for samples with low WBC counts. However, it cannot be recommended as a suitable alternative for manual differential cytologic workup.

  2. Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens.

    Science.gov (United States)

    Schapkaitz, Elise; Khoza, Phoyisile

    2017-09-26

    Automated hematology analyzers generate white blood cell (WBC) suspect flags to indicate smears requiring manual review. In a human immunodeficiency virus (HIV) patient population with a high frequency of abnormal specimens, the usefulness of these flags depends on their sensitivity and specificity. The white cell precursor (WPC) channel on the Sysmex XN-9000 analyzer (Sysmex Corporation, Kobe, Japan) has recently been introduced in order to distinguish immature cells such as blasts and abnormal lymphocytes. The efficiency of the flags generated by WPC reflex testing was compared to the white cell differential (WDF) on the Sysmex XN-9000 in 400 routine HIV samples. A flag was generated by the WDF channel in 346 (86.50%) samples. Addition of the WPC to the WDF resulted in a 20.99% reduction in the smear review rate. WPC analysis correctly identified the initial WDF flag in 59 (60.82%) samples with 'blasts?' or 'abnormal lympho?' flags. WPC showed an excellent sensitivity of 100%. However, the specificity remained poor. On investigation, samples with chronic infection/inflammation (35.00%) and lymphopenia (63.25%) were associated with a high false positive rate of 76.32% and 55.56%, respectively. WPC analysis removed 45 (51.72%) coexisting 'atypical lympho?' false positive WDF flags. The 'atypical lympho?' flag showed an increased sensitivity and specificity of 88.46% and 74.67%, respectively. White cell precursor reflex testing showed improved flagging efficiency for the 'atypical lympho?' flag, which was a good indicator of reactive lymphocytes during chronic infection/inflammation. Nevertheless, the false positive rate for 'abnormal lympho/blasts?' was high in the presence of lymphopenia and infection. © 2017 Wiley Periodicals, Inc.

  3. Reference intervals for mean platelet volume and immature platelet fraction determined on a sysmex XE5000 hematology analyzer

    DEFF Research Database (Denmark)

    Jørgensen, Mikala Klok; Bathum, L.

    2016-01-01

    Background New parameters describing the platelet population of the blood are mean platelet volume (MPV), which is a crude estimate of thrombocyte reactivity, and immature platelet fraction (IPF), which reflects megakaryopoietic activity. This study aimed to define reference intervals for MPV...... and IPF and to investigate whether separate reference intervals according to smoking status, age or sex are necessary.Methods Blood samples were obtained from subjects participating in The Danish General Suburban Population Study. MPV and IPF measurements were performed by the use of the Sysmex XE-5000...

  4. The value of the white precursor cell channel (WPC) on the Sysmex XN-1000 analyser in a specialist paediatric hospital.

    Science.gov (United States)

    Jones, Amanda S; Tailor, Hitesh; Liesner, Ri; Machin, Samuel J; Briggs, Carol J

    2015-02-01

    Historically, haematology analyser flags for abnormal white blood cells (WBCs) show good sensitivity but lower specificity, causing unnecessary blood film reviews. While the WBC differential channel on Sysmex XE and XN instruments reports a combined flag for blasts/abnormal lymphocytes, the new white precursor cell channel (WPC) on the XN series has been introduced to separate this into a specific flag for either cell type or, if no abnormality, remove the flag entirely. To compare the efficiency of abnormal WBC flags from the XN WPC to our existing analyser and determine whether WPC can reduce false positive flags and blood films required. Abnormal WBC flags from the Sysmex XE-5000 and XN-1000 were compared to manual differential and blood film morphology on 300 K2EDTA samples from infants and children. The XN WPC flag for blasts was more sensitive and specific than flags indicating blasts on the XE-5000, with a reduction in false positives from 64% (XE) to 36% (XN). Overall efficiency of the WPC flag for abnormal lymphocytes was 94% vs 79% on the XE. WPC reduced false positive flags for blasts and abnormal lymphocytes on neonatal samples by 50%. Automatic reflex analysis by WPC correctly removed a false positive flag from the white cell differential channel on 46% of samples. Total abnormal WBC flags from XN WPC were less (73) than the XE-5000 (92). XN WPC demonstrated superior efficiency of abnormal WBC flags on paediatric samples, compared to the XE-5000, with greater sensitivity and specificity of flagging, reducing blood films for review. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  6. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  7. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  8. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  9. Decoherence at absolute zero

    OpenAIRE

    Sinha, Supurna

    2005-01-01

    We present an analytical study of the loss of quantum coherence at absolute zero. Our model consists of a harmonic oscillator coupled to an environment of harmonic oscillators at absolute zero. We find that for an Ohmic bath, the offdiagonal elements of the density matrix in the position representation decay as a power law in time at late times. This slow loss of coherence in the quantum domain is qualitatively different from the exponential decay observed in studies of high temperature envir...

  10. Comparison of haematological parameters determined by the Sysmex KX - 2IN automated haematology analyzer and the manual counts

    Directory of Open Access Journals (Sweden)

    Shu Elvis N

    2010-04-01

    Full Text Available Abstract Background This study was designed to determine the correlation between heamatological parameters by Sysmex KX-21N automated hematology analyzer with the manual methods. Method Sixty (60 subjects were randomly selected from both apparently healthy subjects and those who have different blood disorders from the University of Teaching Hospital (UNTH, Ituku-Ozalla, Enugu, Enugu State, Nigeria. Three (3mls of venous blood sample was collected aseptically from each subject into tri-potassium ethylenediamine tetra-acetic acid (K3EDTA for the analysis of haematological parameters using the automated and the manual methods. Results The blood film report by the manual method showed that 50% of the subjects were normocytic-normochromic while the other 50% revealed different abnormal blood pictures. Also, there were statistically significant differences (p Conclusion From the present study, it can be concluded that the automated hematology analyzer readings correlated well with readings by the standard manual method, although the latter method gave additional diagnostic information on the blood pictures. While patients' care and laboratory operations could be optimized by using manual microscopic examination as a reflective substitute for automated methods, usage of automated method would ease our workload and save time for patients.

  11. Assessment of blood sample stability for complete blood count using the Sysmex XN-9000 and Mindray BC-6800 analyzers

    Directory of Open Access Journals (Sweden)

    Sabrina Buoro

    Full Text Available ABSTRACT BACKGROUND: Different hematological analyzers have different analytical performances that are often reflected in the criteria for sample stability of the complete blood count. This study aimed to assess the stability of several hematological parameters using the XN-9000 Sysmex and BC-6800 Mindray analyzers. METHODS: The impact of storage at room temperature and 4 °C was evaluated after 2, 4, 6, 8, 24, 36 and 48 h using ten normal and 40 abnormal blood samples. The variation from the baseline measurement was evaluated by the Steel-Dwass-Critchlow-Fligner test and by Bland-Altman plots, using quality specifications and critical difference as the total allowable variation. RESULTS: Red blood cells and reticulocyte parameters (i.e. hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, red blood cell distribution width, immature reticulocyte fractions, low-fluorescence reticulocytes, middle-fluorescence reticulocytes, high fluorescence mononuclear cells showed less stability compared to leukocyte and platelet parameters (except for monocyte count and mean platelet volume. The bias for hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration and red blood cell distribution width coefficient of variation was higher than the critical difference after 8 h using both analyzers. CONCLUSION: Blood samples measured with both analyzers do not show analytically significant changes in up to 2 h of storage at room temperature and 4 °C. However, the maximum time for analysis can be extended for up to 8 h when the bias is compared to the critical difference.

  12. A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.

    Science.gov (United States)

    Ciepiela, Olga; Kotuła, Iwona; Kierat, Szymon; Sieczkowska, Sandra; Podsiadłowska, Anna; Jenczelewska, Anna; Księżarczyk, Karolina; Demkow, Urszula

    2016-11-01

    Modern automated laboratory hematology analyzers allow the measurement of over 30 different hematological parameters useful in the diagnostic and clinical interpretation of patient symptoms. They use different methods to measure the same parameters. Thus, a comparison of complete blood count made by Mindray BC-6800, Sysmex XN-2000 and Beckman Coulter LH750 was performed. A comparison of results obtained by automated analysis of 807 anticoagulated blood samples from children and 125 manual microscopic differentiations were performed. This comparative study included white blood cell count, red blood cell count, and erythrocyte indices, as well as platelet count. The present study showed a poor level of agreement between white blood cell enumeration and differentiation of the three automated hematology analyzers under comparison. A very good agreement was found when comparing manual blood smear and automated granulocytes, monocytes, and lymphocytes differentiation. Red blood cell evaluation showed better agreement than white blood cells between the studied analyzers. To conclude, studied instruments did not ensure satisfactory interchangeability and did not facilitate a substitution of one analyzer by another. © 2016 Wiley Periodicals, Inc.

  13. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  14. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 6. Approach to Absolute Zero 0.3 K. to a Few Milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 6 June 1997 pp 6-14. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/06/0006-0014 ...

  15. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 2. Approach to Absolute Zero From 4. 22 K. to 0. 3 K. R Srinivasan. Series Article Volume 2 Issue 2 February 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/02/0008-0016 ...

  16. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  17. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  18. Short preheating at 41°C leads to a red blood cells count comparable to that in RET channel of Sysmex analysers in samples showing cold agglutination.

    Science.gov (United States)

    La Gioia, Antonio; Fumi, Maurizio; Fiorini, Fabiana; Pezzati, Paola; Balboni, Fiamma; Bombara, Maria; Marini, Alessandra; Pancione, Ylenia; Solarino, Leonardo; Marchese, Elisa; Sale, Silvia; Rocco, Vincenzo; Fiorini, Marcello

    2018-03-13

    The presence of cold agglutinin in blood samples can cause a spontaneous agglutination of red blood cells (RBCs) when low temperature occurs. This phenomenon causes a spurious lowering of RBC count on the automated haematological analysers that are detected by incongruous values (≥370 g/L) of the mean cellular haemoglobi concentration (MCHC). A preheating at 37°C can remove the RBC agglutination generally resulting in a reliable count. It has been reported that the same result can be reached by using the optical reticulocyte (RET) channel of Sysmex analysers where the RBC count is not influenced by the presence of cold agglutinin. This study aims to evaluate these data in a larger population, with regard to environmental conditions on Sysmex analysers. We have also evaluated the influence of different thermal pretreatments on the RBC count. This study was performed on 96 remnants of peripheral blood samples (48 with MCHC in normal range and 48 with MCHC > 370 g/L) which have been analysed in different preanalytical conditions on the Sysmex analysers. A preheating of samples at 41°C for 1 min leads to a reversibility of the cold agglutination comparable to the one observed in the RET channel and yields better results compared with 37°C for 2 hours. None of described procedures assure the complete cold agglutination reversibility in every case. Consequently, since the haematological analysers not yet provide reliable parameters to confirm the complete resolution of agglutination, further verification of RBC count accuracy needs to be performed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Canine differential leukocyte counting with the CellaVision DM96Vision, Sysmex XT-2000iV, and Advia 2120 hematology analyzers and a manual method.

    Science.gov (United States)

    Tvedten, Harold W; Lilliehöök, Inger E

    2011-09-01

    For differential leukocyte counts, automated blood smear evaluation systems have been too slow or inaccurate to replace or supplement the manual differential count. The CellaVision DM96Vision (DM96V), a new instrument, is an automated image analysis system that is rapid and accurate enough to be used for enumerating human leukocytes and may be useful for analysis of canine blood. The aims of this study were to evaluate the performance of the DM96V in differential counting of canine leukocytes, to compare its performance with that of other methods, and to analyze interoperator variability. Four methods of determining the leukocyte differential count of 108 canine blood samples were compared based on agreement, precision, and errors as well as relative performance. Differential counts were obtained using the DM96V, the manual method, and automated methods performed by the Advia 2120 and Sysmex XT-2000iV. All leukocyte types were detected by the DM96V and the manual method, and all 4 methods had similar mean and median results in most cases. The automated methods were more precise than either the DM96V or manual method when comparing identification of a single type of leukocyte, especially neutrophils and lymphocytes. However, precision of the automated methods was only fair for monocytes, and the Advia and Sysmex failed to identify basophils. The Advia reported fewer monocytes and eosinophils than did the other methods. Significantly fewer lymphocytes were identified by the manual method than by the Sysmex, Advia, and DM96V. The DM96V occasionally presented duplicate images of the same neutrophils. The CellaVision DM96V is a satisfactory system for facilitating canine differential leukocyte counting. The DM96V differential count was more similar to the manual count than to automated counts, which were more precise but had errors and omissions in detecting some types of leukocytes. ©2011 American Society for Veterinary Clinical Pathology.

  20. Comparison of Impedance Platelet Count by Sysmex XE-5000 and Beckman Coulter LH 780 with Optical Fluorescent Platelet Count in Thalassemia Patients

    Directory of Open Access Journals (Sweden)

    Chaicharoen Tantanate, M.D.

    2017-09-01

    Full Text Available Background: Red blood cell (RBC abnormalities are frequently found among thalassemia patients and have been reported to be a cause of spuriously high platelet counts. Objective: To compare impedance platelet count by Sysmex XE-5000 (PLT-XE and Beckman Coulter LH 780 (PLT-LH with optical fluorescent platelet count (PLT-O in thalassemia patients. Methods: EDTA blood specimens from 152 thalassemia patients were analyzed by routine mode of PLT-XE and PLT-LH. The PLT-O run on reticulocyte mode of Sysmex XE-5000 was used as a reference method. Spearman’s rank correlation coefficient (rs and Bland-Altman plot were analyzed. Results: Correlations between impedance and PLT-O methods were excellent, as demonstrated by rs of 0.95 and 0.97 for PLT-XE and PLT-LH, respectively. However, there was no agreement between impedance and PLT-O methods. There were differences in biases of PLT-XE between thalassemia minor and both thalassemia intermedia and major. Compared to PLT-O, the concordance rates of diagnosis for platelet count abnormality were 94.7% and 96.7% for PLT-XE and PLT-LH, respectively. Conclusion: Compared to PLT-O, impedance method was associated with spuriously high platelet counts in thalassemia patients. Careful blood smear examination and/or accurate assay should be used in cases suspected of spuriously high platelet count.

  1. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...... to the lasso. The lasso is applied both directly as a calibration method and as a method to select important variables/wave lengths. It is demonstrated that the lasso algorithm, in general, leads to parameter estimates of which some are zero while others are quite large (compared to e.g. the traditional PLS...

  2. Laboratory Diagnosis of Malaria: Comparison of Manual and Automated Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Samina Naz Mukry

    2017-01-01

    Full Text Available Malaria is the second most prevalent disease in Pakistan resulting in ~30,000 annual deaths. In endemic countries like Pakistan precise and timely diagnosis of malaria is imperative to overcome the associated risks of fatal outcomes. Malarial parasite was screened in 128 malaria suspected patients and 150 healthy controls, by species-specific PCR, microscopy of blood smears, hemoanalyzer Sysmex XE-2100, and rapid test devices (First Response Malaria® and ICT Malaria Combo®. The microscopy detected MP in 126 samples (parasite load/µl 386–53712/µl; 71.094% were infected with Plasmodium vivax and 14.844% with P. falciparum while 14.062% had mixed P. vivax and P. falciparum infection. The mean parasite load for P. vivax and P. falciparum was 14496/µl and 24410/µl, respectively. The abnormal scattergrams of DIFF, WBC/ Baso, IMI channel, and RET-EXT on Sysmex XE-2100 supported 99.2% parasite detection, whereas only 93% of confirmed malaria cases were detected by both rapid tests. About 127 samples were positive by PCR. Since Sysmex XE-2100 automatically detected the presence of malarial parasite with high sensitivity, it can be a good option for presumptive diagnosis in endemic areas. Microscopy remains the gold standard to confirm MP in suspected patients. Rapid diagnostic tests have acceptable sensitivity and specificity.

  3. Absolute Gravimetry in Fennoscandia

    DEFF Research Database (Denmark)

    Pettersen, B. R; TImmen, L.; Gitlein, O.

    away from this central location. An oval shaped zero uplift isoline tracks the general western and northern coastline of Norway and the Kola peninsula. It returns southwest through Russian Karelia and touches the southern tip of Sweden and northern Denmark. The uplift area (as measured by present day...... motions) has its major axis in the direction of southwest to northeast and covers a distance of about 2000 km. Absolute gravimetry was made in Finland and Norway in 1976 with a rise-and fall instrument. A decade later the number of gravity stations was expanded by JILAg-5, in Finland from 1988, in Norway...... acquired by IfE (FG5-220), FGI (FG5-221), and UMB (FG5-226). New absolute gravity stations were established by the national mapping agencies in Denmark, Norway, and Sweden. The total number of prepared sites in Fennoscandia is now about 30. Most of them are co-located with permanent GPS, for many of which...

  4. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  5. Absolute risk, absolute risk reduction and relative risk

    Directory of Open Access Journals (Sweden)

    Jose Andres Calvache

    2012-12-01

    Full Text Available This article illustrates the epidemiological concepts of absolute risk, absolute risk reduction and relative risk through a clinical example. In addition, it emphasizes the usefulness of these concepts in clinical practice, clinical research and health decision-making process.

  6. Investigation of morphological changes for the discrimination of nucleated red blood cells and other leukocytes in Sysmex XN hematology analyzer scattergrams using transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Masako Kaido

    2017-08-01

    Full Text Available Background: The WNR channel of the XN-Series automated hematology analyzer (Sysmex counts white blood cells (WBCs and simultaneously performs a differential counting of basophils and nucleated red blood cells (NRBCs. The detection process involves exposing the cells to WNR-specific reagents containing an acidic detergent and a fluorescent dye and measuring the intensity of the forward scattered light (FSC and side fluorescence light (SFL. Method: We treated isolated peripheral WBCs and NRBCs with specific reagents and assessed the morphological changes in NRBCs and each leukocyte type using transmission electron microscopy (TEM. Results: The results from a flow cytometer (FCM showed that, after exposure to the reagents, basophils appeared on the highest FSC and SFL areas compared to other leukocytes on the WNR scattergram. Owing to the hemolysis of reticulocytes and erythrocytes, NRBCs that survived the reagent treatment could be distinguished by their lower intensity than those of the other leukocytes on the WNR scattergram. We investigated the significance of the relationship between the TEM and FCM results after the reagent treatment. Conclusion: We confirmed that the WNR channel differentiates the blood cells on the WNR scattergram based on differences in the amount of residual cytoplasm and nucleic acids. Keywords: Automated hematology analyzer, Flow cytometry, Transmission electron microscopy, Leukocytes, NRBCs, Scatter light intensity, Fluorescent intensity

  7. Measurement of dabigatran: previously demonstrated Hemoclot®Thrombin Inhibitor assay reagent instability on Sysmex CS-2100i is no longer an issue.

    Science.gov (United States)

    Comuth, Willemijn J; Faaborg, Louise; Henriksen, Linda Ø; Münster, Anna-Marie B

    The Hemoclot ® Thrombin Inhibitor (HTI) assay has been recommended for measurement of dabigatran concentrations in specific clinical situations. Traditionally, reagents for biochemical assays are prepared from instructions found in the package insert. For the HTI reagents the manufacturer recommends incubating the reagents much longer than indicated in the package insert. These recommendations are added to the application sheets designed for different analyzers. Many clinicians and laboratory personnel may be unaware of the discrepancy between the two instructions, resulting in incorrect handling of the reagents. The aim of this study was to investigate the effect of the two different preparation methods on reagent stability and test results. For the standard concentration range, reagent stability on Sysmex CS-2100i was only two hours instead of the eight hours indicated by the producer when following package insert instructions (incubation time: 15 min). Stability was increased to five hours when following the application sheet (incubation time: 60 min). Two years later, the study was repeated using samples of patients treated with dabigatran etexilate. This time, reagent stability was at least six hours. Since the reagent composition was unchanged, the increased stability could be due to changed logistics by the supplier, with stock and transfer closer by. Previously demonstrated HTI reagent instability is no longer an issue at our laboratory. The reliability of results of clinical studies in which the assay has been used is potentially compromised.

  8. Effect of prewarming EDTA blood samples to 37°C on platelet count measured by Sysmex XT-2000iV in dogs, cats, and horses.

    Science.gov (United States)

    Williams, Tim L; Archer, Joy

    2016-09-01

    Pseudothrombocytopenia secondary to platelet clumping is a common cause of preanalytic error for platelet counts in dogs, cats, and horses. In human beings, it is suggested that prewarming blood samples to 37°C prior to hematology analysis will reduce platelet clumping. The purpose of the study was to evaluate the effect of prewarming EDTA blood samples to 37°C on measured platelet counts and other hematologic variables. The EDTA blood samples from dogs, cats and horses submitted to the clinical pathology laboratory at the University of Cambridge were included. Complete blood cell counts performed using a Sysmex XT-2000iV hematology analyzer were done on samples at room temperature (approximately 22°C) and following warming of the samples to 37°C in a water bath. The Wilcoxon signed rank test was used to compare hematologic variables, including platelet count, before and after sample warming to 37°C. Data are presented as median (25(th) , 75(th) percentile) increase. Blood samples from 39 dogs, 19 cats, and 10 horses were included. Sample warming to 37°C resulted in a statistically significant increase in platelet counts in dogs (11 [-2, 30] ×10(9) /L), cats (36 [14, 84] ×10(9) /L), and horses (42 [31, 79] ×10(9) /L). Sample warming did not significantly affect other hematologic variables. Prewarming EDTA blood samples to 37°C prior to hematologic analysis increased platelet counts overall in canine, feline, and equine blood, but did not abrogate platelet clumping and pseudothrombocytopenia fully in some cases. Furthermore, true pseudothrombocytopenia was not confirmed in these animals. © 2016 American Society for Veterinary Clinical Pathology.

  9. Validação de tecnologia 5diff do analisador hematológico Sysmex XS-1000i para laboratório de pequeno/médio porte Validation of 5diff technologies of the Sysmex XS-1000i hematology analyzer for small and medium laboratories

    Directory of Open Access Journals (Sweden)

    Luiz F. Borges

    2009-08-01

    Full Text Available O Sysmex XS-1000i® é um novo e compacto analisador hematológico com tecnologia 5diff e citometria de fluxo fluorescente, tecnologias até então presentes em equipamentos de grande porte e disponíveis apenas para equivalentes rotinas laboratoriais. Neste estudo avaliamos seu desempenho com equipamento de análise de impedãncia (Coulter T-890® e à contagem diferencial de 200 leucócitos em microscópio. Foram analizadas 100 amostras paralelamente nos dois equipamentos e submetidas à contagem diferencial de 200 células em distensão sanguínea. Os resultados foram analisados mediante análise de correlação de Spearman para dados não paramétricos, mostrando correlação superior a 95% para os parâmetros WBC, RBC, hemoglobina, hematócrito e neutrófilos; correlação entre 90% e 94,9% para VCM, HCM, linfócitos e eosinófilos ; correlação inferior a 89,9 % para CHCM, monócitos e basófilos. Os resultados obtidos sugerem que a tecnologia embarcada neste equipamento é uma versátil ferramenta para o analista na rotina de pequeno e médio porte. No entanto, em caso de emissão de "flags" não dispensa totalmente a confirmação ao microscópio para garantia da qualidade final do exame.The Sysmex XS-1000i® is a new and compact blood analyzer with 5diff technology and fluorescent flow cytometry, technologies hitherto only present in large equipment and available only for laboratory equivalent routines. In this study its performance was compared with equipment for impedance analysis (Coulter T-890® and the microscopic counting of 200 differential leukocytes. One hundred samples were evaluated in parallel by both apparatuses and subjected to differential counts of 200 cells. The results were analyzed using the Spearman correlation for parametric data showing no correlation greater than 95% for white blood cells, red blood cells, hemoglobin, hematocrit and neutrophils,; correlations between 90% and 94.9% for VCM, MCH, lymphocytes and

  10. Absolute metrology for space interferometers

    Science.gov (United States)

    Salvadé, Yves; Courteville, Alain; Dändliker, René

    2017-11-01

    The crucial issue of space-based interferometers is the laser interferometric metrology systems to monitor with very high accuracy optical path differences. Although classical high-resolution laser interferometers using a single wavelength are well developed, this type of incremental interferometer has a severe drawback: any interruption of the interferometer signal results in the loss of the zero reference, which requires a new calibration, starting at zero optical path difference. We propose in this paper an absolute metrology system based on multiplewavelength interferometry.

  11. Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit.

    Science.gov (United States)

    Rudolf, Joseph; Douglass, Joseph; Baron, Jason; Lewandrowski, Kent

    2015-06-15

    Conductivity based point-of-care hematocrit with calculated hemoglobin devices serves an important role in clinical scenarios where time sensitive transfusion decisions are necessary. However, questions about the appropriateness of conductivity based assays in certain patient populations (patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions) have been raised. The clinical suitability of POC devices for these applications necessitates that they be accurate and that the results are interchangeable with central laboratory methods. We performed hematocrit and hemoglobin analysis on 225 clinical samples using the i-STAT instrument, a standard reference method for hematocrit (manual spun) and other common methods on both cardiopulmonary bypass and non-cardiopulmonary bypass patients. The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method (p=0.4085, Wilcoxon signed rank test) or the Sysmex photometric hemoglobin method (p=0.2728, Wilcoxon signed rank test). The results on the i-STAT were statistically different from those obtained on the Sysmex for hematocrit (phemoglobin (phematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Absolute pitch--electrophysiological evidence.

    Science.gov (United States)

    Barnea, A; Granot, R; Pratt, H

    1994-02-01

    People who have the ability to label or to produce notes without any reference are considered to possess Absolute Pitch (AP). Others, who need a reference in order to identify the notes, possess Relative Pitch (RP). The AP ability is assumed to reflect a unique, language-like representation of non-lexical musical notes in memory. The purpose of this study was to examine this assumption by comparing Event Related Potentials (ERP) of musicians with and without AP, to lexical and non-lexical representation of musical material. Subjects were eighteen young adult musicians. Seven were AP and eleven RP. Auditory stimuli, presented through earphones, were piano notes (non-lexical) or a voice saying the note's name (lexical). Visual stimuli, presented on a computer display were note symbols (non-lexical) or letters (lexical). Subjects performed a number of tasks, combining the two modalities (visual and auditory) and stimulus types (lexical and non-lexical), and reaction times (RT), performance accuracy and evoked potentials were recorded. The tasks forced the subjects to transfer mental representations of musical material from one mode to another. Our most important findings were the differences, between groups, in the scalp distribution of P300 amplitudes. We conclude that absolute pitch possessors use the same internal language as relative pitch possessors, when possible, but the distribution of the underlying brain activity is different between AP and RP subjects.

  13. Absolute MR thermometry using nanocarriers.

    Science.gov (United States)

    Deckers, Roel; Sprinkhuizen, Sara M; Crielaard, Bart J; Ippel, Johannes H; Boelens, Rolf; Bakker, Chris J G; Storm, Gert; Lammers, Twan; Bartels, Lambertus W

    2014-01-01

    Accurate time-resolved temperature mapping is crucial for the safe use of hyperthermia-mediated drug delivery. We here propose a magnetic resonance imaging temperature mapping method in which drug delivery systems serve not only to improve tumor targeting, but also as an accurate and absolute nano-thermometer. This method is based on the temperature-dependent chemical shift difference between water protons and the protons in different groups of drug delivery systems. We show that the chemical shift of the protons in the ethylene oxide group in polyethylene glycol (PEG) is temperature-independent, whereas the proton resonance of water decreases with increasing temperature. The frequency difference between both resonances is linear and does not depend on pH and physiological salt conditions. In addition, we show that the proton resonance of the methyl group in N-(2-hydroxypropyl)-methacrylamide (HPMA) is temperature-independent. Therefore, PEGylated liposomes, polymeric mPEG-b-pHPMAm-Lac2 micelles and HPMA copolymers can provide a temperature-independent reference frequency for absolute magnetic resonance (MR) thermometry. Subsequently, we show that multigradient echo MR imaging with PEGylated liposomes in situ allows accurate, time-resolved temperature mapping. In conclusion, nanocarrier materials may serve as highly versatile tools for tumor-targeted drug delivery, acting not only as hyperthermia-responsive drug delivery systems, but also as accurate and precise nano-thermometers. Copyright © 2014 John Wiley & Sons, Ltd.

  14. "Absolute" sterility and "absolute" freedom from particle contamination.

    Science.gov (United States)

    Knapp, J Z

    1998-01-01

    Until the recent past, sterility of an injectable product was only discussed in absolute terms. Any description of sterility other than as an absolute could simply not be envisioned. While dealing in absolute yes/no statements is philosophically satisfying, these yes/no statements can't accommodate all real world scientific problems. Among these problems is the sterility problems faced in the mass production of injectable compounds. Many descriptions of procedures employed to achieve sterility in parenteral production batches were reported in the literature. The theoretical framework that could unite the widespread observations and practices into practical methodology was missing until recently. Production line control of the sterility of injectable products was essentially based on gut evaluations. The present achievement of rational, production line control of product sterility is based on the recognition that product sterility could not be simply regarded as a sharply edged yes/no affair. The present rational control is based on the fact that the sterility of a product is determined by the degree of contamination in the product prior to sterilization and to the parameters of the sterilization process. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. The essential laboratory measurements on which this conclusion was based is due to Pflug (1-3). He assembled a theoretical framework, based on experimental data, that characterizes the sterility achieved in an injectable product with a single number. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. As in many disciplines, the ability to achieve an objective evaluation of this important attribute provided the basis for scientific analysis, improved control and thus improved production and reduced cost. An equivalent framework is essential for the communication and

  15. AUTOMATED HEMATOLOGY ANALYZERS IN DIAGNOSIS OF PLASMODIUM VIVAX MALARIA: AN ADJUNCT TO CONVENTIONAL MICROSCOPY.

    Directory of Open Access Journals (Sweden)

    Kolakkadan Mubeen Hasaf

    2014-05-01

    Full Text Available Malaria is one of the most pervasive parasitic diseases ever known to mankind affecting nearly 300 million people every year. The need for rapid diagnosis of malaria in tropical and subtropical malaria endemic areas is on the rise. In this study we evaluated the usefulness of hematology autoanalyzers, Sysmex XE-2100 & XT-2000i in the presumptive diagnosis of malaria. Our study shows that abnormalities in WBC/BASO scattergram when combined with presence of thrombocytopenia had a high sensitivity and positive predictive value in the presumptive diagnosis of malaria.

  16. High accuracy absolute distance metrology

    Science.gov (United States)

    Swinkels, Bas L.; Bhattacharya, Nandini; Verlaan, Ad L.; Braat, Joseph J. M.

    2017-11-01

    One of ESA's future missions is the Darwin Space Interferometer, which aims to detect planets around nearby stars using optical aperture synthesis with free-flying telescopes. Since this involves interfering white (infra-red) light over large distances, the mission is not possible without a complex metrology system that monitors various speeds, distances and angles between the satellites. One of its sub-systems should measure absolute distances with an accuracy of around 70 micrometer over distances up to 250 meter. To enable such measurements, we are investigating a technique called frequency sweeping interferometry, in which a single laser is swept over a large known frequency range. Central to our approach is the use of a very stable, high finesse Fabry-Ṕerot cavity, to which the laser is stabilized at the endpoints of the frequency sweep. We will discuss the optical set-up, the control system that controls the fast sweeping, the calibration and the data analysis. We tested the system using long fibers and achieved a repeatability of 50 micrometers at a distance of 55 meters. We conclude with some recommendations for further improvements and the adaption for use in space.

  17. Absolutely summing multilinear operators: a Panorama | Pellegrino ...

    African Journals Online (AJOL)

    This paper has a twofold purpose: to present an overview of the theory of absolutely summing operators and its different generalizations for the multilinear setting, and to sketch the beginning of a research project related to an objective search of “perfect” multilinear extensions of the ideal of absolutely summing operators.

  18. MEAN OF MEDIAN ABSOLUTE DERIVATION TECHNIQUE MEAN ...

    African Journals Online (AJOL)

    eobe

    The accurate estimation of noise variance in an image is the first important stage ... lung image was lung image was developed. developed. developed. The development of mean of median absolute derivation technique development of mean of median absolute .... that are non-real numbers during initial processing.

  19. Quantum nonequilibrium equalities with absolute irreversibility

    Science.gov (United States)

    Funo, Ken; Murashita, Yûto; Ueda, Masahito

    2015-07-01

    We derive quantum nonequilibrium equalities in absolutely irreversible processes. Here by absolute irreversibility we mean that in the backward process the density matrix does not return to the subspace spanned by those eigenvectors that have nonzero weight in the initial density matrix. Since the initial state of a memory and the postmeasurement state of the system are usually restricted to a subspace, absolute irreversibility occurs during the measurement and feedback processes. An additional entropy produced in absolutely irreversible processes needs to be taken into account to derive nonequilibrium equalities. We discuss a model of a feedback control on a qubit system to illustrate the obtained equalities. By introducing N heat baths each composed of a qubit and letting them interact with the system, we show how the entropy reduction via feedback control can be converted into work. An explicit form of extractable work in the presence of absolute irreversibility is given.

  20. The absolute environmental performance of buildings

    DEFF Research Database (Denmark)

    Brejnrod, Kathrine Nykjær; Kalbar, Pradip; Petersen, Steffen

    2017-01-01

    sustainability for the standard house were proposed focusing on three measures: minimizing environmental impacts from building construction, minimizing impacts from energy consumption during use phase, and reducing the living area per person. In an intermediate path, absolute sustainability can be obtained...... by reducing the impacts from construction by 89%, use phase energy consumption by 80%, and the living area by 60%.......Our paper presents a novel approach for absolute sustainability assessment of a building's environmental performance. It is demonstrated how the absolute sustainable share of the earth carrying capacity of a specific building type can be estimated using carrying capacity based normalization factors...

  1. ASTEROID ABSOLUTE MAGNITUDES V10.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2006 March 14 batch of Minor Planet Circulars.

  2. ASTEROID ABSOLUTE MAGNITUDES V11.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2007 April 2 batch of Minor Planet Circulars.

  3. ASTEROID ABSOLUTE MAGNITUDES V12.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2008 April 20 batch of Minor Planet Circulars.

  4. ASTEROID ABSOLUTE MAGNITUDES V7.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set tabulates the IAU-adopted absolute V magnitude and slope parameter for all numbered asteroids as of the given stop date. The data set is updated yearly.

  5. ASTEROID ABSOLUTE MAGNITUDES V9.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2005 April 7 batch of Minor Planet Circulars.

  6. ASTEROID ABSOLUTE MAGNITUDES V8.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Absolute magnitudes and slopes, mostly IAU-adopted with exceptions noted, for all asteroids numbered as of the 2004 April 15 batch of Minor Planet Circulars

  7. Absolutely uniform illumination of laser fusion pellets

    International Nuclear Information System (INIS)

    Schmitt, A.J.

    1984-01-01

    Absolutely uniform illumination of spherical laser fusion pellets is possible when the energy deposition from a single beam is given by a simple cos 2 theta distribution. Conditions can be derived for which the laser beam targeting angles allow this absolute illumination uniformity. Configurations based upon the cube and higher order Platonic solids satisfy the constraints, as well as an infinite class of other less symmetric configurations

  8. Absolutely uniform illumination of laser fusion pellets

    International Nuclear Information System (INIS)

    Schmitt, A.J.

    1984-01-01

    Absolutely uniform illumination of spherical laser fusion pellets is possible when the energy deposition from a single laser beam is given by a simple cos 2 theta distribution. Conditions can be derived for which the laser beam targeting angles allow this absolute illumination uniformity. Configurations based upon the cube and higher order Platonic solids satisfy the constraints, as well as infinite class of other less symmetric configurations

  9. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  10. Effects of bacteria and yeast on WBC counting in three automated hematology counters.

    Science.gov (United States)

    Kim, Hye Ryoun; Park, Bo Rae G; Lee, Mi Kyung

    2008-07-01

    Bacteria or yeast may be observed on peripheral blood smears and may lead to spuriously elevated platelet counts. They have been reported to disturb the white blood cell (WBC) differential count if they clumped together, and a large number of such microorganisms have been shown to increase WBC counts. The purpose of this study was to evaluate the spurious rise in WBC counts according to species of microorganisms and automated hematology analyzers. The species we selected were Staphylococcus aureus, Escherichia coli, Candida albicans, C. tropicalis, C. krusei, C. dubliniensis, C. glabrata, and C. parapsilosis. We investigated the effects of bacteria and yeast on peripheral blood samples by the ADVIA 120/2120 Hematology System, Sysmex XE-2100 (TOA Medical Electronics, Kobe, Japan) and Coulter LH 750 (Beckman Coulter, Miami, FL, USA). C. albicans, C. tropicalis, C. krusei, and C. dubliniensis had an overt effect on the WBC count at concentrations of up to 1-5 x 10(7) colony-forming units (CFU)/mL in three automated cell counters, and C. glabrata and C. parapsilosis, when present at concentrations of 1-5 x 10(8) CFU/mL, caused a significant increase in the WBC count obtained by the Sysmex XE-2100 but not by the ADVIA 120/2120 system and Coulter LH 750 (p bacteria and yeast may give erroneously high WBC counts and differential leukocyte counts and should review the peripheral blood smear by microscopy.

  11. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  12. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    Science.gov (United States)

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed.

  13. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  14. The Absolute Normal Scores Test for Symmetry

    Science.gov (United States)

    Penfield, Douglas A.; Sachdeva, Darshan

    1976-01-01

    The absolute normal scores test is described as a test for the symmetry of a distribution of scores about a location parameter. The test is compared to the sign test and the Wilcoxon test as an alternative to the "t"-test. (Editor/RK)

  15. The Theory of Absolute Reaction Rates

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 7. The Theory of Absolute Reaction Rates. Henry Eyring. Classics Volume 17 Issue 7 July 2012 pp 704-711. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/017/07/0704-0711. Author Affiliations.

  16. 49 CFR 236.709 - Block, absolute.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Block, absolute. 236.709 Section 236.709 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION...

  17. Thin-film magnetoresistive absolute position detector

    NARCIS (Netherlands)

    Groenland, J.P.J.

    1990-01-01

    The subject of this thesis is the investigation of a digital absolute posi- tion-detection system, which is based on a position-information carrier (i.e. a magnetic tape) with one single code track on the one hand, and an array of magnetoresistive sensors for the detection of the information on the

  18. Det demokratiske argument for absolut ytringsfrihed

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2014-01-01

    Artiklen diskuterer den påstand, at absolut ytringsfrihed er en nødvendig forudsætning for demokratisk legitimitet med udgangspunkt i en rekonstruktion af et argument fremsat af Ronald Dworkin. Spørgsmålet er, hvorfor ytringsfrihed skulle være en forudsætning for demokratisk legitimitet, og hvorf...

  19. Absolute Distance Measurements with Tunable Semiconductor Laser

    Czech Academy of Sciences Publication Activity Database

    Mikel, Břetislav; Číp, Ondřej; Lazar, Josef

    T118, - (2005), s. 41-44 ISSN 0031-8949 R&D Projects: GA AV ČR(CZ) IAB2065001 Keywords : tunable laser * absolute interferometer Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.661, year: 2004

  20. Stimulus Probability Effects in Absolute Identification

    Science.gov (United States)

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  1. systemic complications following absolute alcohol embolisation of ...

    African Journals Online (AJOL)

    of the superficial temporal (STA), middle meningeal. (MMA) and occipital ... external jugular vein. Absolute alcohol was injected into the feeder artery using the intermittent pulsed spray technique in aliquots of 1 ml. A total of 55 ml of alcohol was injected. ... cells, vessel wall necrosis resulting in thrombosis and permanent ...

  2. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  3. Absolute tightness: the chemists hesitate to invest

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The safety requirements of industries as nuclear plants and the strengthening of regulations in the field of environment (more particularly those related to volatile organic compounds) have lead the manufacturers to build absolute tightness pumps. But these equipments do not answer all the problems and represent a high investment cost. In consequence, the chemists hesitate to invest. (O.L.)

  4. The Absolute Shielding Constants of Heavy Nuclei: Resolving the Enigma of the (119)Sn Absolute Shielding.

    Science.gov (United States)

    Malkin, Elena; Komorovsky, Stanislav; Repisky, Michal; Demissie, Taye B; Ruud, Kenneth

    2013-02-07

    We demonstrate that the apparent disagreement between experimental determinations and four-component relativistic calculations of the absolute shielding constants of heavy nuclei is due to the breakdown of the commonly assumed relation between the electronic contribution to the nuclear spin-rotation constants and the paramagnetic contribution to the NMR shielding constants. We demonstrate that this breakdown has significant consequences for the absolute shielding constant of (119)Sn, leading to errors of about 1000 ppm. As a consequence, we expect that many absolute shielding constants of heavy nuclei will be in need of revision.

  5. From Hubble's NGSL to Absolute Fluxes

    Science.gov (United States)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  6. Trapped individual ion at absolute zero temperature

    Science.gov (United States)

    Yu, Nan; Dehmelt, Hans; Nagourney, Warren

    1989-01-01

    Laser cooling and ion trapping have progressed to such an extent that one can now speak of realizing a confined atom at absolute zero temperature. In this short publication, we analyze an experiment toward such realization using a single Ba+ ion in a miniature rf trap. The Ba+ ion is first laser-cooled to the limit where the ion spends most of its time in the zero-point energy state. Then a test sequence allows one to verify whether or not the ion is actually in its zero-point state. The test sequence may also serve as a device for state selection of an atom at absolute zero temperature. PMID:16594054

  7. Interpolation of uniformly absolutely continuous operators

    Czech Academy of Sciences Publication Activity Database

    Cobos, F.; Gogatishvili, Amiran; Opic, B.; Pick, L.

    2013-01-01

    Roč. 286, 5-6 (2013), s. 579-599 ISSN 0025-584X R&D Projects: GA ČR GA201/08/0383 Institutional support: RVO:67985840 Keywords : uniformly absolutely continuous operators * interpolation * type of an interpolation method Subject RIV: BA - General Mathematics Impact factor: 0.658, year: 2013 http://onlinelibrary.wiley.com/doi/10.1002/ mana .201100205/full

  8. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  9. Benzofuranoid and bicyclooctanoid neolignans:absolute configuration

    International Nuclear Information System (INIS)

    Alvarenga, M.A. de; Giesbrecht, A.M.; Gottlieb, O.R.; Yoshida, M.

    1977-01-01

    The naturally occuring benzofuranoid and bicyclo (3,2,1) octanoid neolignans have their relative configurations established by 1 H and 13 C NMR, inclusively with aid of the solvent shift technique. Interconversion of the benzofuranoid type compounds, as well as for a benzofuranoid to a bicyclooctanoid derivate, make ORD correlations, ultimately with (2S, 3S) - and (2R,3R)-2,3- dihydrobenzofurans, possible, and led to the absolute configurations of both series of neolignans [pt

  10. Immature Reticulocyte Fraction and Absolute Neutrophil Count as Predictor of Hemopoietic Recovery in Patients with Acute Lymphoblastic Leukemia on Remission Induction Chemotherapy

    Directory of Open Access Journals (Sweden)

    Shan E. Rauf

    2016-05-01

    Full Text Available Objective: Acute lymphoblastic leukemia (ALL encompasses a group of lymphoid neoplasms that are more common in children and arise from B-and T-lineage lymphoid precursor cells. The immature reticulocyte fraction (IRF, a new routine parameter in hematology analyzers, can give an indication of hemopoietic recovery like absolute neutrophil count (ANC. The purpose of this study was to evaluate IRF in excess of 5% was considered as IRF recovery. Materials and Methods: In this descriptive study, 2.5 to 3 mL of EDTA blood of 45 ALL patients undergoing the remission induction phase of their treatment was sampled and analyzed with a Sysmex XE-5000 on day 1 and every second day thereafter until the day of recovery. ANC of >0.5x109/L on the day corresponding to the first of the three consecutive counts was considered as the day of ANC recovery. IRF recovery was an IRF in excess of 5%. Results: The mean age of the patients was 12.04±5.30 years; 25 patients (55.6% were male and 20 patients (44.4% were female. On day 1 of induction remission, the mean IRF value was 9.68±1.41, while the mean ANC value was 0.077±0.061. Mean recovery day for IRF was 11.84±7.44 and mean recovery day for ANC was 17.67±8.77 (twotailed p-value <0.0001 with 95% confidence interval. By day 28, out of 45 patients 36 (80% showed ANC recovery, while 41 (91% showed IRF recovery. The remaining patients who had not shown recovery by day 28 were further followed up and all of them showed recovery of both parameters by day 39. Conclusion: This study concluded that postinduction bone marrow hemopoietic recovery was earlier by IRF than ANC in children with ALL on chemotherapy

  11. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  12. Absolute Priority for a Vehicle in VANET

    Science.gov (United States)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  13. Musical Activity Tunes Up Absolute Pitch Ability

    DEFF Research Database (Denmark)

    Dohn, Anders; Garza-Villarreal, Eduardo A.; Ribe, Lars Riisgaard

    2014-01-01

    Absolute pitch (AP) is the ability to identify or produce pitches of musical tones without an external reference. Active AP (i.e., pitch production or pitch adjustment) and passive AP (i.e., pitch identification) are considered to not necessarily coincide, although no study has properly compared...... that APs generally undershoot when adjusting musical pitch, a tendency that decreases when musical activity increases. Finally, APs are less accurate when adjusting the pitch to black key targets than to white key targets. Hence, AP ability may be partly practice-dependent and we speculate that APs may...

  14. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  15. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  16. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    Science.gov (United States)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  17. Absolute and Relative Time-Consistent Revealed Preferences

    OpenAIRE

    T. DEMUYNCK

    2007-01-01

    We introduce an Absolute (Relative) Time-consistent Axiom of Revealed Preference which characterizes the consistency of a choice function with the property of absolute (relative) time-consistency and impatience. The axiom requires that the absolute (relative) time-consistent and impatient closure of the revealed preference relation does not conflict with the strict revealed preference relation.

  18. Absolute ion hydration enthalpies from absolute hardness and some VBT relationships

    Science.gov (United States)

    Kaya, Savaş; Fernandes de Farias, Robson

    2018-01-01

    In the present work, absolute hydration enthalpies are calculated from ion absolute hardness for a series of +1 and -1 ions. The calculated values are compared with those previously reported (Housecroft, 2017) [2] and relationships between Vm-1/3 and absolute hardness are stablished. The following empirical equations have been derived, for cations and anions, respectively: ΔhydHo = -(9.645 η+ + 245.930) and ΔhydHo = -(64.601 η- + 12.321). In such equations, η+ and η- are the absolute hardness. It is shown that for d block monocations (Cu+, Ag+ and Au+), hydration enthalpy is closely related with Clementi effective nuclear charge by the equation: ΔhydHo = -(9.645 η+ + 245.930) (Zeff/(n - 1)), where n is the main quantum number. Furthermore, is shown that a typical VBT parameter (Vm-1/3) is related with η+ and η- values and so, with the energies of the frontier orbitals, that is, is stablished a direct relationship between a structural parameter available by X-ray data and the energy of atomic/molecular orbitals.

  19. Absolute beam current monitoring in endstation c

    International Nuclear Information System (INIS)

    Bochna, C.

    1995-01-01

    The first few experiments at CEBAF require approximately 1% absolute measurements of beam currents expected to range from 10-25μA. This represents errors of 100-250 nA. The initial complement of beam current monitors are of the non intercepting type. CEBAF accelerator division has provided a stripline monitor and a cavity monitor, and the authors have installed an Unser monitor (parametric current transformer or PCT). After calibrating the Unser monitor with a precision current reference, the authors plan to transfer this calibration using CW beam to the stripline monitors and cavity monitors. It is important that this be done fairly rapidly because while the gain of the Unser monitor is quite stable, the offset may drift on the order of .5μA per hour. A summary of what the authors have learned about the linearity, zero drift, and gain drift of each type of current monitor will be presented

  20. How is an absolute democracy possible?

    Directory of Open Access Journals (Sweden)

    Joanna Bednarek

    2011-01-01

    Full Text Available In the last part of the Empire trilogy, Commonwealth, Negri and Hardt ask about the possibility of the self-governance of the multitude. When answering, they argue that absolute democracy, understood as the political articulation of the multitude that does not entail its unification (construction of the people is possible. As Negri states, this way of thinking about political articulation is rooted in the tradition of democratic materialism and constitutes the alternative to the dominant current of modern political philosophy that identifies political power with sovereignty. The multitude organizes itself politically by means of the constitutive power, identical with the ontological creativity or productivity of the multitude. To state the problem of political organization means to state the problem of class composition: political democracy is at the same time economic democracy.

  1. Absolute negative mobility in the anomalous diffusion

    Science.gov (United States)

    Chen, Ruyin; Chen, Chongyang; Nie, Linru

    2017-12-01

    Transport of an inertial Brownian particle driven by the multiplicative Lévy noise was investigated here. Numerical results indicate that: (i) The Lévy noise is able to induce absolute negative mobility (ANM) in the system, while disappearing in the deterministic case; (ii) the ANM can occur in the region of superdiffusion while disappearing in the region of normal diffusion, and the appropriate stable index of the Lévy noise makes the particle move along the opposite direction of the bias force to the maximum degree; (iii) symmetry breaking of the Lévy noise also causes the ANM effect. In addition, the intrinsic physical mechanism and conditions for the ANM to occur are discussed in detail. Our results have the implication that the Lévy noise plays an important role in the occurrence of the ANM phenomenon.

  2. MLU and IPSyn measuring absolute complexity

    Directory of Open Access Journals (Sweden)

    Lea Nieminen

    2009-05-01

    Full Text Available This article compares the results of Mean Length of Utterance (MLU and Index of Productive Syntax (IPSyn with the structural complexity of spontaneous utterances produced by 30-month-old Finnish children in a semi-structured playing situation. The comparison was carried out in order to determine the aspects of structural complexity which can be detected with MLU and IPSyn. This research adopts the frameworks of absolute complexity together with a multidimensional view of utterance structure and, furthermore, applies it through Utterance Analysis (UA. The results of the comparison between the metrics and changes in structural complexity discovered by UA reveal that MLU and IPSyn do function as measures of structural complexity but only if used in close relation to each other. Because they focus on different aspects of utterances, the results of both metrics should be interpreted in relation to one another.DOI: http://dx.doi.org/10.5128/ERYa5.11

  3. WHY DOES LEIBNIZ NEED ABSOLUTE TIME?

    Directory of Open Access Journals (Sweden)

    NICOLÁS VAUGHAN C.

    2007-08-01

    Full Text Available Resumen: En este ensayo pongo en contraposición dos doctrinas conspicuamenteleibnicianas: la doctrina del tiempo relacional e ideal, y la doctrina de la armonía preestablecida. Argumentaré que si todas las substancias están necesariamentecoordinadas, entonces no tiene sentido negar el carácter absoluto y real del tiempo. En la primera sección describiré la concepción newtoniana y clarkeana del tiempo absoluto; en la segunda discutiré la crítica leibniciana a dicha concepción, crítica sobre la que se erige su doctrina relacional e ideal del tiempo; en la tercera sección daré un vistazo a la metafísica monádica madura de Leibniz, haciendo especial énfasis en la doctrina de la armonía preestablecida; finalmente, en la última sección sugeriré la existencia de una tensión irreconciliable entre estas dos doctrinas.Abstract: In this paper I bring together two characteristically Leibnizean doctrines:the doctrine of relational and ideal time, and the doctrine of preestablished harmony. I will argue that, if every substance is necessarily connected with another, then it makes no sense to deny absolute and real time. In the first section, I will describe Newton’s and Clarke’s conception of absolute time; then, in the second section, I will consider Leibniz’s critique of that conception, on which he bases his ideal and relational doctrine of time. In the third section I will look briefly at Leibniz’s mature monadic metaphysics, taking special account of his doctrine of preestablished harmony. In the last section, I will suggest that there is an irreconcilable tension between these two doctrines.

  4. What is Needed for Absolute Paleointensity?

    Science.gov (United States)

    Valet, J. P.

    2015-12-01

    Many alternative approaches to the Thellier and Thellier technique for absolute paleointensity have been proposed during the past twenty years. One reason is the time consuming aspect of the experiments. Another reason is to avoid uncertainties in determinations of the paleofield which are mostly linked to the presence of multidomain grains. Despite great care taken by these new techniques, there is no indication that they always provide the right answer and in fact sometimes fail. We are convinced that the most valid approach remains the original double heating Thellier protocol provided that natural remanence is controlled by pure magnetite with a narrow distribution of small grain sizes, mostly single domains. The presence of titanium, even in small amount generates biases which yield incorrect field values. Single domain grains frequently dominate the magnetization of glass samples, which explains the success of this selective approach. They are also present in volcanic lava flows but much less frequently, and therefore contribute to the low success rate of most experiments. However the loss of at least 70% of the magnetization at very high temperatures prior to the Curie point appears to be an essential prerequisite that increases the success rate to almost 100% and has been validated from historical flows and from recent studies. This requirement can easily be tested by thermal demagnetization while low temperature experiments can document the detection of single domain magnetite using the δFC/δZFC parameter as suggested (Moskowitz et al, 1993) for biogenic magnetite.

  5. Evaluation of the absolute regional temperature potential

    Directory of Open Access Journals (Sweden)

    D. T. Shindell

    2012-09-01

    Full Text Available The Absolute Regional Temperature Potential (ARTP is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90–28° S, 28° S–28° N, 28–60° N and 60–90° N as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within ±20% of the actual responses, though there are some exceptions for 90–28° S and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the ±20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39–45% and 9–39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  6. Absolute Radiometric Calibration of KOMPSAT-3A

    Directory of Open Access Journals (Sweden)

    H. Y. Ahn

    2016-06-01

    Full Text Available This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A performed by the Korea Aerospace Research Institute (KARI and the Pukyong National University Remote Sensing Group (PKNU RSG in 2015.The primary stages of this study are summarized as follows: (1 A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2 To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4. Correlations between top-of-atmosphere (TOA radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  7. Absolute parameters of young stars: QZ Carinae

    Science.gov (United States)

    Walker, W. S. G.; Blackford, M.; Butland, R.; Budding, E.

    2017-09-01

    New high-resolution spectroscopy and BVR photometry together with literature data on the complex massive quaternary star QZ Car are collected and analysed. Absolute parameters are found as follows. System A: M1 = 43 (±3), M2 = 19 (+3 -7), R1 = 28 (±2), R2 = 6 (±2), (⊙); T1 ˜ 28 000, T2 ˜ 33 000 K; System B: M1 = 30 (±3), M2 = 20 (±3), R1 = 10 (±0.5), R2 = 20 (±1), (⊙); T1 ˜ 36 000, T2 ˜ 30 000 K (model dependent temperatures). The wide system AB: Period = 49.5 (±1) yr, Epochs, conjunction = 1984.8 (±1), periastron = 2005.3 (±3) yr, mean separation = 65 (±3), (au); orbital inclination = 85 (+5 -15) deg, photometric distance ˜2700 (±300) pc, age = 4 (±1) Myr. Other new contributions concern: (a) analysis of the timing of minima differences (O - C)s for the eclipsing binary (System B); (b) the width of the eclipses, pointing to relatively large effects of radiation pressure; (c) inferences from the rotational widths of lines for both Systems A and B; and (d) implications for theoretical models of early-type stars. While feeling greater confidence on the quaternary's general parametrization, observational complications arising from strong wind interactions or other, unclear, causes still inhibit precision and call for continued multiwavelength observations. Our high-inclination value for the AB system helps to explain failures to resolve the wide binary in the previous years. The derived young age independently confirms membership of QZ Car to the open cluster Collinder 228.

  8. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. Planck absolute entropy of a rotating BTZ black hole

    Science.gov (United States)

    Riaz, S. M. Jawwad

    2018-04-01

    In this paper, the Planck absolute entropy and the Bekenstein-Smarr formula of the rotating Banados-Teitelboim-Zanelli (BTZ) black hole are presented via a complex thermodynamical system contributed by its inner and outer horizons. The redefined entropy approaches zero as the temperature of the rotating BTZ black hole tends to absolute zero, satisfying the Nernst formulation of a black hole. Hence, it can be regarded as the Planck absolute entropy of the rotating BTZ black hole.

  10. Absolute chronology and stratigraphy of Lepenski Vir

    Directory of Open Access Journals (Sweden)

    Borić Dušan

    2007-01-01

    Full Text Available In the last decade, a number of specialist analyses were made on the material from old excavations of Mesolithic-Neolithic sites in the Danube Gorges. These new results altered significantly our understanding of the Lepenski Vir culture. The question of chronology of this regional phenomenon has been acute since the discovery of Lepenski Vir in the 1960s, and it remains of key importance for understanding the character of Mesolithic-Neolithic transformations in this and the neighbouring regions. The most heated debate was fuelled by the initial stratigraphic and chronological attribution of the type-site itself. There remained the question about the adequate dating of the most prominent phase at this site characterized by buildings with trapezoidal bases covered with limestone floors and with rectangular stone-lined hearths placed in the centre of these features. There have been suggestions that these features also contain Early Neolithic Starčevo type pottery and other similar items of material culture and should thus be dated to the Early Neolithic historical context. Moreover, the first series of conventional radiocarbon determinations (21 dates also suggested that the absolute chronology of these features should be confined to the period from around 6400-5500 cal BC (Fig. 1. Due to the importance of defining more precisely the chronology for the start of construction of these particular features at Lepenski Vir and for establishing the life-span of these buildings and their associated material culture, we have AMS (Accelerator Mass Spectrometry dated a number of contexts from this site. The results are presented in this paper. The project was made possible through the Oxford Radiocarbon Accelerate Dating Service (ORADS programme funded by the Arts and Humanities Research Council (AHRC and the Natural Environment Research Council (NERC of the Great Britain. Apart from those dates presented in this paper, there are 29 previously published

  11. Does Absolute Synonymy exist in Owere-Igbo? | Omego | AFRREV ...

    African Journals Online (AJOL)

    Among Igbo linguistic researchers, determining whether absolute synonymy exists in Owere–Igbo, a dialect of the Igbo language predominantly spoken by the people of Owerri, Imo State, Nigeria, has become a thorny issue. While some linguistic scholars strive to establish that absolute synonymy exists in the lexical ...

  12. Determination of Absolute Zero Using a Computer-Based Laboratory

    Science.gov (United States)

    Amrani, D.

    2007-01-01

    We present a simple computer-based laboratory experiment for evaluating absolute zero in degrees Celsius, which can be performed in college and undergraduate physical sciences laboratory courses. With a computer, absolute zero apparatus can help demonstrators or students to observe the relationship between temperature and pressure and use…

  13. A developmental study of latent absolute pitch memory.

    Science.gov (United States)

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  14. Mini-implants and miniplates generate sub-absolute and absolute anchorage.

    Science.gov (United States)

    Consolaro, Alberto

    2014-01-01

    The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces. Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

  15. Mini-implants and miniplates generate sub-absolute and absolute anchorage

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-06-01

    Full Text Available The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces.Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

  16. Performance of the XN-2000 WPC channel-flagging to differentiate reactive and neoplastic leukocytosis.

    Science.gov (United States)

    Schuff-Werner, Peter; Kohlschein, Peter; Maroz, Aliaksandra; Linssen, Joachim; Dreißiger, Katrin; Burstein, Christine

    2016-09-01

    The distinction between reactive and neoplastic leukocytes, especially atypical lymphocytes suspected to be reactive or neoplastic, is a particular challenge in automated hematological cell differentiation. The aim of the study was to evaluate the performance of the XN analyzer supplemented with the WPC channel for differentiating between reactive and neoplastic leukocytosis. Blood samples of 253 patients with viral infections, lymphoma or leukemia were analyzed by the Sysmex XN-2000 analyzer equipped with the WPC channel. The results were compared to routine leukocyte differentiation using the routine Sysmex XE-2100 analyzer and automated digital microscopy (DM96). The combined information from standard morphology, immune phenotyping and clinical diagnosis served as a reference. The XN WPC channel demonstrated an excellent performance for differentiating neoplastic (AUC=0.933) and reactive leukocytosis (AUC=0.900) as compared to morphological smear examination (AUC=0.949 and AUC=0.968, respectively) or to the differentiation results of our routine hematology analyzer (AUC=0.630 and AUC=0.635, respectively). Our data show that the combined WDF/WPC of the Sysmex XN-Series analyzer is advantageous in the automated differentiation of neoplastic and reactive leukocytosis, thus supporting the correct diagnostic decision in the daily laboratory routine.

  17. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  18. Prognostic Value of Absolute versus Relative Rise of Blood ...

    African Journals Online (AJOL)

    maternal outcome than a relative rise in the systolic/diastolic blood pressure from mid pregnancy, which did not reach this absolute level. We conclude that in the Nigerian obstetric population, the practice of diagnosing pregnancy hypertension on ...

  19. Efficacy of intrahepatic absolute alcohol in unrespectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Hameed, K.; Khan, I.U.; Shah, S.

    2001-01-01

    To determine efficacy of intrahepatic absolute alcohol injection in researchable hepatocellular carcinoma. A randomized, controlled, experimental and interventional clinical trial. Gastroenterology Department, PGMI, Hayatabad Medical Complex, Peshawar during the period from June, 1998 to June, 2000. Thirty patients were treated by percutaneous, intrahepatic absolute alcohol injection sin repeated sessions, 33 patients were not given or treated with alcohol to serve as control. Both the groups were comparable for age, sex and other baseline characteristics. Absolute alcohol therapy significantly improved quality of life of patients, reduced the tumor size and mortality as well as showed significantly better results regarding survival (P< 0.05) than the patients of control group. We conclude that absolute alcohol is a beneficial and safe palliative treatment measure in advanced hepatocellular carcinoma (HCC). (author)

  20. Changes in Absolute Sea Level Along U.S. Coasts

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map shows changes in absolute sea level from 1960 to 2016 based on satellite measurements. Data were adjusted by applying an inverted barometer (air pressure)...

  1. Absolute Continuity of Stable Foliations for Mappings of Banach Spaces

    Science.gov (United States)

    Blumenthal, Alex; Young, Lai-Sang

    2017-09-01

    We prove the absolute continuity of stable foliations for mappings of Banach spaces satisfying conditions consistent with time- t maps of certain classes of dissipative PDEs. This property is crucial for passing information from submanifolds transversal to the stable foliation to the rest of the phase space; it is also used in proofs of ergodicity. Absolute continuity of stable foliations is well known in finite dimensional hyperbolic theory. On Banach spaces, the absence of nice geometric properties poses some additional difficulties.

  2. Auditory working memory predicts individual differences in absolute pitch learning.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Koch, Rachelle; Nusbaum, Howard C

    2015-07-01

    Absolute pitch (AP) is typically defined as the ability to label an isolated tone as a musical note in the absence of a reference tone. At first glance the acquisition of AP note categories seems like a perceptual learning task, since individuals must assign a category label to a stimulus based on a single perceptual dimension (pitch) while ignoring other perceptual dimensions (e.g., loudness, octave, instrument). AP, however, is rarely discussed in terms of domain-general perceptual learning mechanisms. This is because AP is typically assumed to depend on a critical period of development, in which early exposure to pitches and musical labels is thought to be necessary for the development of AP precluding the possibility of adult acquisition of AP. Despite this view of AP, several previous studies have found evidence that absolute pitch category learning is, to an extent, trainable in a post-critical period adult population, even if the performance typically achieved by this population is below the performance of a "true" AP possessor. The current studies attempt to understand the individual differences in learning to categorize notes using absolute pitch cues by testing a specific prediction regarding cognitive capacity related to categorization - to what extent does an individual's general auditory working memory capacity (WMC) predict the success of absolute pitch category acquisition. Since WMC has been shown to predict performance on a wide variety of other perceptual and category learning tasks, we predict that individuals with higher WMC should be better at learning absolute pitch note categories than individuals with lower WMC. Across two studies, we demonstrate that auditory WMC predicts the efficacy of learning absolute pitch note categories. These results suggest that a higher general auditory WMC might underlie the formation of absolute pitch categories for post-critical period adults. Implications for understanding the mechanisms that underlie the

  3. Absolute Navigation Information Estimation for Micro Planetary Rovers

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2016-03-01

    Full Text Available This paper provides algorithms to estimate absolute navigation information, e.g., absolute attitude and position, by using low power, weight and volume Microelectromechanical Systems-type (MEMS sensors that are suitable for micro planetary rovers. Planetary rovers appear to be easily navigable robots due to their extreme slow speed and rotation but, unfortunately, the sensor suites available for terrestrial robots are not always available for planetary rover navigation. This makes them difficult to navigate in a completely unexplored, harsh and complex environment. Whereas the relative attitude and position can be tracked in a similar way as for ground robots, absolute navigation information, unlike in terrestrial applications, is difficult to obtain for a remote celestial body, such as Mars or the Moon. In this paper, an algorithm called the EASI algorithm (Estimation of Attitude using Sun sensor and Inclinometer is presented to estimate the absolute attitude using a MEMS-type sun sensor and inclinometer, only. Moreover, the output of the EASI algorithm is fused with MEMS gyros to produce more accurate and reliable attitude estimates. An absolute position estimation algorithm has also been presented based on these on-board sensors. Experimental results demonstrate the viability of the proposed algorithms and the sensor suite for low-cost and low-weight micro planetary rovers.

  4. Relative and absolute risk in epidemiology and health physics

    International Nuclear Information System (INIS)

    Goldsmith, R.; Peterson, H.T. Jr.

    1983-01-01

    The health risk from ionizing radiation commonly is expressed in two forms: (1) the relative risk, which is the percentage increase in natural disease rate and (2) the absolute or attributable risk which represents the difference between the natural rate and the rate associated with the agent in question. Relative risk estimates for ionizing radiation generally are higher than those expressed as the absolute risk. This raises the question of which risk estimator is the most appropriate under different conditions. The absolute risk has generally been used for radiation risk assessment, although mathematical combinations such as the arithmetic or geometric mean of both the absolute and relative risks, have also been used. Combinations of the two risk estimators are not valid because the absolute and relative risk are not independent variables. Both human epidemiologic studies and animal experimental data can be found to illustrate the functional relationship between the natural cancer risk and the risk associated with radiation. This implies that the radiation risk estimate derived from one population may not be appropriate for predictions in another population, unless it is adjusted for the difference in the natural disease incidence between the two populations

  5. Absolute marine gravimetry with matter-wave interferometry.

    Science.gov (United States)

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.

  6. Adjustment and testing comparison of absolute gravimeters in November 2013

    Directory of Open Access Journals (Sweden)

    Alena Pešková

    2017-07-01

    Full Text Available This paper is focused on a comparison measurement processing of absolute gravimeters in 2013. The comparison deals with a number of various types of absolute gravimeters and includes also an absolute gravimeter from Geodetic observatory Pecný. Comparative measurements are performed to detect systematic errors of gravimeters. A result of processing is most likely value of a gravity and a systematic error of individual devices. Measured values are input to a adjustment with condition a sum of systematic errors is zero. A part of this process is also verification following output: (i value of a posteriori standard deviation, (ii size of corrections and (iii statistical significance of systematic errors. The results of adjustment are 15 gravity values on the reference places and 25 systematic errors of measuring instruments. Result shows that the presence of systematic errors in measurements is not statistically provable because the systematic errors are similarly sized as their standard deviation.

  7. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Directory of Open Access Journals (Sweden)

    Sander K R van Zon

    Full Text Available The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender.The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender.Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups.Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and

  8. Absolute and Relative Socioeconomic Health Inequalities across Age Groups.

    Science.gov (United States)

    van Zon, Sander K R; Bültmann, Ute; Mendes de Leon, Carlos F; Reijneveld, Sijmen A

    2015-01-01

    The magnitude of socioeconomic health inequalities differs across age groups. It is less clear whether socioeconomic health inequalities differ across age groups by other factors that are known to affect the relation between socioeconomic position and health, like the indicator of socioeconomic position, the health outcome, gender, and as to whether socioeconomic health inequalities are measured in absolute or in relative terms. The aim is to investigate whether absolute and relative socioeconomic health inequalities differ across age groups by indicator of socioeconomic position, health outcome and gender. The study sample was derived from the baseline measurement of the LifeLines Cohort Study and consisted of 95,432 participants. Socioeconomic position was measured as educational level and household income. Physical and mental health were measured with the RAND-36. Age concerned eleven 5-years age groups. Absolute inequalities were examined by comparing means. Relative inequalities were examined by comparing Gini-coefficients. Analyses were performed for both health outcomes by both educational level and household income. Analyses were performed for all age groups, and stratified by gender. Absolute and relative socioeconomic health inequalities differed across age groups by indicator of socioeconomic position, health outcome, and gender. Absolute inequalities were most pronounced for mental health by household income. They were larger in younger than older age groups. Relative inequalities were most pronounced for physical health by educational level. Gini-coefficients were largest in young age groups and smallest in older age groups. Absolute and relative socioeconomic health inequalities differed cross-sectionally across age groups by indicator of socioeconomic position, health outcome and gender. Researchers should critically consider the implications of choosing a specific age group, in addition to the indicator of socioeconomic position and health outcome

  9. Neural sensitivity to absolute and relative anticipated reward in adolescents.

    Directory of Open Access Journals (Sweden)

    Jatin G Vaidya

    Full Text Available Adolescence is associated with a dramatic increase in risky and impulsive behaviors that have been attributed to developmental differences in neural processing of rewards. In the present study, we sought to identify age differences in anticipation of absolute and relative rewards. To do so, we modified a commonly used monetary incentive delay (MID task in order to examine brain activity to relative anticipated reward value (neural sensitivity to the value of a reward as a function of other available rewards. This design also made it possible to examine developmental differences in brain activation to absolute anticipated reward magnitude (the degree to which neural activity increases with increasing reward magnitude. While undergoing fMRI, 18 adolescents and 18 adult participants were presented with cues associated with different reward magnitudes. After the cue, participants responded to a target to win money on that trial. Presentation of cues was blocked such that two reward cues associated with $.20, $1.00, or $5.00 were in play on a given block. Thus, the relative value of the $1.00 reward varied depending on whether it was paired with a smaller or larger reward. Reflecting age differences in neural responses to relative anticipated reward (i.e., reference dependent processing, adults, but not adolescents, demonstrated greater activity to a $1 reward when it was the larger of the two available rewards. Adults also demonstrated a more linear increase in ventral striatal activity as a function of increasing absolute reward magnitude compared to adolescents. Additionally, reduced ventral striatal sensitivity to absolute anticipated reward (i.e., the difference in activity to medium versus small rewards correlated with higher levels of trait Impulsivity. Thus, ventral striatal activity in anticipation of absolute and relative rewards develops with age. Absolute reward processing is also linked to individual differences in Impulsivity.

  10. Clinical application of absolute ethanol as an embolizing material

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Chang, Kee Hyun; Han, Man Chung

    1982-01-01

    Transcatheter infusion of absolute ethanol was applied clinically in 3 cases of artificial embolization: 25 yrs old female with bilateral renal angiomyolipoma, 19 yrs old female with right paralumbar liposarcoma and 25 yrs old male with hypernephroma of right kidney. Selective or subselective manual infusion was made and 9 to 22 cc of pure ethanol was delivered in a speed of 1 to 2 cc per second. The sclerosing effect of absolute ethanol was potent. However, all 3 cases revealed mild post-embolization syndrome

  11. Absolute Stability Analysis of a Phase Plane Controlled Spacecraft

    Science.gov (United States)

    Jang, Jiann-Woei; Plummer, Michael; Bedrossian, Nazareth; Hall, Charles; Jackson, Mark; Spanos, Pol

    2010-01-01

    Many aerospace attitude control systems utilize phase plane control schemes that include nonlinear elements such as dead zone and ideal relay. To evaluate phase plane control robustness, stability margin prediction methods must be developed. Absolute stability is extended to predict stability margins and to define an abort condition. A constrained optimization approach is also used to design flex filters for roll control. The design goal is to optimize vehicle tracking performance while maintaining adequate stability margins. Absolute stability is shown to provide satisfactory stability constraints for the optimization.

  12. Absolute gain measurement by the image method under mismatched condition

    Science.gov (United States)

    Lee, Richard Q.; Baddour, Maurice F.

    1987-01-01

    Purcell's image method for measuring the absolute gain of an antenna is particularly attractive for small test antennas. The method is simple to use and utilizes only one antenna with a reflecting plane to provide an image for the receiving antenna. However, the method provides accurate results only if the antenna is matched to its waveguide. In this paper, a waveguide junction analysis is developed to determine the gain of an antenna under mismatched condition. Absolute gain measurements for two standard gain horn antennas have been carried out. Experimental results agree closely with published data.

  13. Absolute and conditional convergence within Sonora state municipalities, 1989- 2004

    Directory of Open Access Journals (Sweden)

    Joaquín Bracamontes Neváre

    2008-07-01

    Full Text Available This paper tries to identify the existence of convergence, absolut as muchas conditional, for the municipalities that conform the state of Sonora. Taking as abase the methodologic excercise of Mankiw, Romer and Weill (1992 that considersthe first model of Solow (1956 and makes an extension of it including thehuman capital, evidence shows that there is no tendency for poor municipalitiesto grow more quickly than rich municipalities, which means that there is no processof convergence –nor absolute or conditional– in the municipalities of Sonora,independently of the development layer in which these are classified: municipalitieswith high, average or low development.

  14. Total synthesis and absolute configuration of the marine norditerpenoid xestenone.

    Science.gov (United States)

    Ota, Koichiro; Kurokawa, Takao; Kawashima, Etsuko; Miyaoka, Hiroaki

    2009-11-24

    Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  15. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  16. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    Science.gov (United States)

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  17. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    NARCIS (Netherlands)

    Hernandez, E. M.; Juarez, A. M.; Kilcoyne, A. L. D.; Aguilar, A.; Hernandez, L.; Antillon, A.; Macaluso, D.; Morales-Mori, A.; Gonzalez-Magana, O.; Hanstorp, D.; Covington, A. M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    The photoionization of Cl+ leading to Cl2+ was measured in the photon energy range of 19.5-28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl+ ion beam with a photon beam of

  18. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    Science.gov (United States)

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises,…

  19. Mechanism for an absolute parametric instability of an inhomogeneous plasma

    Science.gov (United States)

    Arkhipenko, V. I.; Budnikov, V. N.; Gusakov, E. Z.; Romanchuk, I. A.; Simonchik, L. V.

    1984-05-01

    The structure of plasma oscillations in a region of parametric spatial amplification has been studied experimentally for the first time. A new mechanism for an absolute parametric instability has been observed. This mechanism operates when a pump wave with a spatial structure more complicated than a plane wave propagates through a plasma which is inhomogeneous along more than one dimension.

  20. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2015-01-01

    The global absolute poverty rates of the World Bank demonstrate a continued decline of poverty in developing countries between 1983 and 2012. However, the methodology applied to derive these results has received extensive criticism by scholars for requiring the application of PPP exchange rates and

  1. Global Absolute Poverty: Behind the Veil of Dollars

    NARCIS (Netherlands)

    Moatsos, M.

    2017-01-01

    The widely applied “dollar-a-day” methodology identifies global absolute poverty as declining precipitously since the early 80’s throughout the developing world. The methodological underpinnings of the “dollar-a-day” approach have been questioned in terms of adequately representing equivalent

  2. An improved generalized Newton method for absolute value equations.

    Science.gov (United States)

    Feng, Jingmei; Liu, Sanyang

    2016-01-01

    In this paper, we suggest and analyze an improved generalized Newton method for solving the NP-hard absolute value equations [Formula: see text] when the singular values of A exceed 1. We show that the global and local quadratic convergence of the proposed method. Numerical experiments show the efficiency of the method and the high accuracy of calculation.

  3. Multipliers for the absolute Euler summability of Fourier series

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    (Math. Sci.), Vol. 111, No. 2, May 2001, pp. 203–219. Printed in India. Multipliers for the absolute Euler summability of Fourier series. PREM CHANDRA. School of Studies in Mathematics, Vikram University, Ujjain 456 010, India. MS received 30 December 1999; revised 30 October 2000. Abstract. In this paper, the author ...

  4. Predicting accurate absolute binding energies in aqueous solution

    DEFF Research Database (Denmark)

    Jensen, Jan Halborg

    2015-01-01

    Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic. In this paper I summarize some of the many factors that could easily contribute 1-3 kcal...

  5. Planck absolute entropy of a rotating BTZ black hole

    Indian Academy of Sciences (India)

    S. M. Jawwad Riaz

    2018-03-06

    Mar 6, 2018 ... Abstract. In this paper, the Planck absolute entropy and the Bekenstein–Smarr formula of the rotating. Banados–Teitelboim–Zanelli (BTZ) black hole are presented via a complex thermodynamical system con- tributed by its inner and outer horizons. The redefined entropy approaches zero as the ...

  6. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  7. 20 CFR 404.1205 - Absolute coverage groups.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Absolute coverage groups. 404.1205 Section 404.1205 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY...) Employees of a State's political subdivision performing services in connection with that subdivision's...

  8. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Pie Valls, B; Pietrzyk, B; Pilar, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; du Pree, T; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shao, B; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skottowe, H P; Skwarnicki, T; Smith, A C; Smith, N A; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Styles, N; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Vervink, K; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Voong, D; Vorobyev, A; Voss, H; Wacker, K; Wandernoth, S; Wang, J; Ward, D R; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  9. Dominated operators, absolutely summing operators and the strict ...

    African Journals Online (AJOL)

    b(X;E) be the space of all E-valued bounded continuous functions on X, equipped with the strict topology β. We study dominated and absolutely summing operators T : Cb(X;E) → F. We derive that if X is a locally compact Hausdorff space and E ...

  10. NIST Stars: Absolute Spectrophotometric Calibration of Vega and Sirius

    Science.gov (United States)

    Deustua, Susana; Woodward, John T.; Rice, Joseph P.; Brown, Steven W.; Maxwell, Stephen E.; Alberding, Brian G.; Lykke, Keith R.

    2018-01-01

    Absolute flux calibration of standard stars, traceable to SI (International System of Units) standards, is essential for 21st century astrophysics. Dark energy investigations that rely on observations of Type Ia supernovae and precise photometric redshifts of weakly lensed galaxies require a minimum accuracy of 0.5 % in the absolute color calibration. Studies that aim to address fundamental stellar astrophysics also benefit. In the era of large telescopes and all sky surveys well-calibrated standard stars that do not saturate and that are available over the whole sky are needed. Significant effort has been expended to obtain absolute measurements of the fundamental standards Vega and Sirius (and other stars) in the visible and near infrared, achieving total uncertainties between1% and 3%, depending on wavelength, that do not meet the needed accuracy. The NIST Stars program aims to determine the top-of-the-atmosphere absolute spectral irradiance of bright stars to an uncertainty less than 1% from a ground-based observatory. NIST Stars has developed a novel, fully SI-traceable laboratory calibration strategy that will enable achieving the desired accuracy. This strategy has two key components. The first is the SI-traceable calibration of the entire instrument system, and the second is the repeated spectroscopic measurement of the target star throughout the night. We will describe our experimental strategy, present preliminary results for Vega and Sirius and an end-to-end uncertainty budget

  11. Confirmation of the absolute configuration of (−)-aurantioclavine

    KAUST Repository

    Behenna, Douglas C.

    2011-04-01

    We confirm our previous assignment of the absolute configuration of (-)-aurantioclavine as 7R by crystallographically characterizing an advanced 3-bromoindole intermediate reported in our previous synthesis. This analysis also provides additional support for our model of enantioinduction in the palladium(II)-catalyzed oxidative kinetic resolution of secondary alcohols. © 2010 Elsevier Ltd. All rights reserved.

  12. DESIGN AND CONSTRUCTION OF AN ABSOLUTE GRAVITY METER

    African Journals Online (AJOL)

    An absolute gravimeter which has been designed and constructed consists of a timing circuit which measures the time a body takes to fall between two points separated by a known distance. The time of fall and the known distance are used to calculate the acceleration of gravity at the point of experimentation.

  13. Absolutely continuous spectrum and spectral transition for some ...

    Indian Academy of Sciences (India)

    Absolutely continuous spectrum and spectral transition for some continuous random operators. M KRISHNA. Institute of Mathematical Sciences, Taramani, Chennai 600 113, India. E-mail: krishna@imsc.res.in. MS received 28 February 2010; revised 6 June 2011. Dedicated to Barry Simon for his 65th birthday. Abstract.

  14. Frequency Windows of Absolute Negative Conductance in Josephson Junctions

    OpenAIRE

    Machura, L.; Kostur, M.; Talkner, P.; Hanggi, P.; Luczka, J.

    2007-01-01

    We report on anomalous conductance in a resistively and capacitively shunted Josephson junction which is simultaneously driven by ac and dc currents. The dependence of the voltage across the junction on the frequency of the ac current shows windows of absolute negative conductance regimes, i.e. for a positive (negative) dc current, the voltage is negative (positive).

  15. Relative versus Absolute Stimulus Control in the Temporal Bisection Task

    Science.gov (United States)

    de Carvalho, Marilia Pinhiero; Machado, Armando

    2012-01-01

    When subjects learn to associate two sample durations with two comparison keys, do they learn to associate the keys with the short and long samples (relational hypothesis), or with the specific sample durations (absolute hypothesis)? We exposed 16 pigeons to an ABA design in which phases A and B corresponded to tasks using samples of 1 s and 4 s,…

  16. Use of absolute lymphocyte count or neutrophil ingestion rate of ...

    African Journals Online (AJOL)

    The present study was designed to evaluate absolute lymphocyte count or neutrophil ingestion rate of NBT as alternative indices to CD4+ T cell count in the management of HIV/AIDS subjects. 158 adult participants (male = 70, female = 88) were recruited for the study and grouped as: (i) Symptomatic HIV subjects with or ...

  17. Necessity and sufficiency conditions for the absolute null ...

    African Journals Online (AJOL)

    We are inspired by the works of Chukwu [1], Eke [2], Schinterdorf and Barmish [4] to unveil necessary and sufficient conditions for the absolute null controllability of a linear delay perturbed system with zero in the domain of null controllability. Journal of the Nigerian Association of Mathematical Physics Vol. 10 2006: pp. 549- ...

  18. Absolute Stability of Discrete-Time Systems with Delay

    Directory of Open Access Journals (Sweden)

    Medina Rigoberto

    2008-01-01

    Full Text Available We investigate the stability of nonlinear nonautonomous discrete-time systems with delaying arguments, whose linear part has slowly varying coefficients, and the nonlinear part has linear majorants. Based on the "freezing" technique to discrete-time systems, we derive explicit conditions for the absolute stability of the zero solution of such systems.

  19. DOES ABSOLUTE SYNONYMY EXIST IN OWERE-IGBO?

    African Journals Online (AJOL)

    USER

    or emotional overtones, etc. These are explained below: A. Contextual Differences: One of the implications of absolute synonymy is that it must be possible for synonyms to be used interchangeably in all sentence contexts. But our analyses of the sentences above as given by native speakers indicated that there are some ...

  20. The Absolute and the Relative Dimensions of Constitutional Rights

    Czech Academy of Sciences Publication Activity Database

    Alexy, Robert

    2017-01-01

    Roč. 37, č. 1 (2017), s. 31-47 ISSN 0143-6503 Keywords : constitutional rights * judicial review * proportionality Subject RIV: AG - Legal Sciences OBOR OECD: Law Impact factor: 1.242, year: 2016 https://academic.oup.com/ojls/article/37/1/31/2669583/The-Absolute-and-the-Relative-Dimensions-of

  1. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is considered.

  2. Absolute parametric instability in a nonuniform plane plasma ...

    Indian Academy of Sciences (India)

    Abstract. The paper reports an analysis of the effect of spatial plasma nonuniformity on absolute parametric instability (API) of electrostatic waves in magnetized plane waveguides subjected to an intense high-frequency (HF) electric field using the separation method. In this case the effect of strong static magnetic field is ...

  3. Absolute intensity calibration for ECE measurements on EAST

    International Nuclear Information System (INIS)

    Liu Yong; Liu Xiang; Zhao Hailin

    2014-01-01

    In this proceeding, the results of the in-situ absolute intensity calibration for ECE measurements on EAST are presented. A 32-channel heterodyne radiometer system and a Michelson interferometer on EAST have been calibrated independently, and preliminary results from plasma operation indicate a good agreement between the electron temperature profiles obtained with different systems. (author)

  4. Fabricating the absolute fake: America in contemporary pop culture

    NARCIS (Netherlands)

    Kooijman, J.

    2008-01-01

    Onze wereld wordt gedomineerd door de Amerikaanse popcultuur. Fabricating the Absolute Fake onderzoekt de dynamiek van Amerikanisering aan de hand van hedendaagse films, televisieprogramma's en popsterren die reflecteren op de vraag wat het betekent om Amerikaan in een mondiale popcultuur te zijn.

  5. On quantum harmonic oscillator being subjected to absolute ...

    Indian Academy of Sciences (India)

    On quantum harmonic oscillator being subjected to absolute potential state. SWAMI NITYAYOGANANDA. Ramakrishna Mission Ashrama, R.K. Beach, Visakhapatnam 530 003, India. E-mail: nityayogananda@gmail.com. MS received 1 May 2015; accepted 6 May 2016; published online 3 December 2016. Abstract.

  6. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the ∑ n ≤ N f(n)$ with explicit error term. As a corollary we obtain new results about sum-of-divisors functions and Jordan's totient functions.

  7. Partial sums of arithmetical functions with absolutely convergent ...

    Indian Academy of Sciences (India)

    , Chennai 600 113, India. E-mail: biswajyoti@imsc.res.in. MS received 9 May 2015; revised 9 July 2015. Abstract. For an arithmetical function f with absolutely convergent Ramanujan expansion, we derive an asymptotic formula for the sum. ∑.

  8. The PMA Catalogue: 420 million positions and absolute proper motions

    Science.gov (United States)

    Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.

    2017-07-01

    We present a catalogue that contains about 420 million absolute proper motions of stars. It was derived from the combination of positions from Gaia DR1 and 2MASS, with a mean difference of epochs of about 15 yr. Most of the systematic zonal errors inherent in the 2MASS Catalogue were eliminated before deriving the absolute proper motions. The absolute calibration procedure (zero-pointing of the proper motions) was carried out using about 1.6 million positions of extragalactic sources. The mean formal error of the absolute calibration is less than 0.35 mas yr-1. The derived proper motions cover the whole celestial sphere without gaps for a range of stellar magnitudes from 8 to 21 mag. In the sky areas where the extragalactic sources are invisible (the avoidance zone), a dedicated procedure was used that transforms the relative proper motions into absolute ones. The rms error of proper motions depends on stellar magnitude and ranges from 2-5 mas yr-1 for stars with 10 mag < G < 17 mag to 5-10 mas yr-1 for faint ones. The present catalogue contains the Gaia DR1 positions of stars for the J2015 epoch. The system of the PMA proper motions does not depend on the systematic errors of the 2MASS positions, and in the range from 14 to 21 mag represents an independent realization of a quasi-inertial reference frame in the optical and near-infrared wavelength range. The Catalogue also contains stellar magnitudes taken from the Gaia DR1 and 2MASS catalogues. A comparison of the PMA proper motions of stars with similar data from certain recent catalogues has been undertaken.

  9. Standardization approaches in absolute quantitative proteomics with mass spectrometry.

    Science.gov (United States)

    Calderón-Celis, Francisco; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo

    2017-07-31

    Mass spectrometry-based approaches have enabled important breakthroughs in quantitative proteomics in the last decades. This development is reflected in the better quantitative assessment of protein levels as well as to understand post-translational modifications and protein complexes and networks. Nowadays, the focus of quantitative proteomics shifted from the relative determination of proteins (ie, differential expression between two or more cellular states) to absolute quantity determination, required for a more-thorough characterization of biological models and comprehension of the proteome dynamism, as well as for the search and validation of novel protein biomarkers. However, the physico-chemical environment of the analyte species affects strongly the ionization efficiency in most mass spectrometry (MS) types, which thereby require the use of specially designed standardization approaches to provide absolute quantifications. Most common of such approaches nowadays include (i) the use of stable isotope-labeled peptide standards, isotopologues to the target proteotypic peptides expected after tryptic digestion of the target protein; (ii) use of stable isotope-labeled protein standards to compensate for sample preparation, sample loss, and proteolysis steps; (iii) isobaric reagents, which after fragmentation in the MS/MS analysis provide a final detectable mass shift, can be used to tag both analyte and standard samples; (iv) label-free approaches in which the absolute quantitative data are not obtained through the use of any kind of labeling, but from computational normalization of the raw data and adequate standards; (v) elemental mass spectrometry-based workflows able to provide directly absolute quantification of peptides/proteins that contain an ICP-detectable element. A critical insight from the Analytical Chemistry perspective of the different standardization approaches and their combinations used so far for absolute quantitative MS-based (molecular and

  10. Towards absolute laser spectroscopic CO2 isotope ratio measurements

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Knowledge of isotope composition of carbon dioxide (CO2) in the atmosphere is necessary to identify sources and sinks of this key greenhouse gas. In the last years, laser spectroscopic techniques such as cavity ring-down spectroscopy (CRDS) and tunable diode laser absorption spectroscopy (TDLAS) have been shown to perform accurate isotope ratio measurements for CO2 and other gases like water vapour (H2O) [1,2]. Typically, isotope ratios are reported in literature referring to reference materials provided by e.g. the International Atomic Energy Agency (IAEA). However, there could be some benefit if field deployable absolute isotope ratio measurement methods were developed to address issues such as exhausted reference material like the Pee Dee Belemnite (PDB) standard. Absolute isotope ratio measurements would be particularly important for situations where reference materials do not even exist. Here, we present CRDS and TDLAS-based absolute isotope ratios (13C/12C ) in atmospheric CO2. We demonstrate the capabilities of the used methods by measuring CO2 isotope ratios in gas standards. We compare our results to values reported for the isotope certified gas standards. Guide to the expression of uncertainty in measurement (GUM) compliant uncertainty budgets on the CRDS and TDLAS absolute isotope ratio measurements are presented, and traceability is addressed. We outline the current impediments in realizing high accuracy absolute isotope ratio measurements using laser spectroscopic methods, propose solutions and the way forward. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] B. Kühnreich, S. Wagner, J. C. Habig,·O. Möhler, H. Saathoff, V. Ebert, Appl. Phys. B 119:177-187 (2015). [2] E. Kerstel, L. Gianfrani, Appl. Phys. B 92, 439-449 (2008).

  11. Henry More and the development of absolute time.

    Science.gov (United States)

    Thomas, Emily

    2015-12-01

    This paper explores the nature, development and influence of the first English account of absolute time, put forward in the mid-seventeenth century by the 'Cambridge Platonist' Henry More. Against claims in the literature that More does not have an account of time, this paper sets out More's evolving account and shows that it reveals the lasting influence of Plotinus. Further, this paper argues that More developed his views on time in response to his adoption of Descartes' vortex cosmology and cosmogony, providing new evidence of More's wider project to absorb Cartesian natural philosophy into his Platonic metaphysics. Finally, this paper argues that More should be added to the list of sources that later English thinkers - including Newton and Samuel Clarke - drew on in constructing their absolute accounts of time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Absolute gravimetry - for monitoring climate change and geodynamics in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil

    be detected in Greenland, resulting from the loading and unloading of ice during winter and summer. Besides this kind of elastic signal, there will also be a more general trend due to the development of the ice. As already indicated, the two geophysical signals under investigation give rise to a vertical...... with the GPS data, it is possible to separate the different signals. The method used in this study is absolute gravimetry. An absolute gravimeter of the A10 type has been purchased by DTU Space for this purpose. This instrument can measure gravity changes as small as 6µGal (= 60nm=s2), which provides...... investigated with different processing methods. These preliminary results of the gravity measurements in Greenland are interesting new data which suggest that as more measurements become available it will be possible, along with the GPS data, to separate the different geodynamical processes and thereby give...

  13. Synesthesia and rhythm. The road to absolute cinema

    Directory of Open Access Journals (Sweden)

    Ricardo Roncero Palomar

    2017-05-01

    Full Text Available Absolute cinema, developed during the historical avant-garde, con-tinued with a long artistic tradition that linked musical with visual experience. Due to cinema as médium of expression, this filmmakers were able to work with the moving image to develop concepts such as rhythm, also with more complex figures than the colored spots that other devices could create at those time. This study starts with the published texts in 1704 by Newton about color, and provides an overview of those artistic highlights that link image and sound, and which creates the origins of absolute cinema. The connections and equivalences between the visual and sound experiences used by these filmmakers are also studied in order to know if there was a continuous line with the origins of these studies or if there was a rupture and other later investigations were able to have more repercussion in their works.

  14. Absolute configuration assignment of (+)-fluralaner using vibrational circular dichroism.

    Science.gov (United States)

    Kong, John; Joyce, Leo A; Liu, Jinchu; Jarrell, Tiffany M; Culberson, J Chris; Sherer, Edward C

    2017-12-01

    The absolute configurations of the separated enantiomers of fluralaner, a racemic animal health product used to prevent fleas and ticks, have been assigned using vibrational circular dichroism (VCD). The crystallographic structure of the active enantiomer (+)-fluralaner has previously been shown to have the (S) configuration using small molecule crystallography. We sought a faster analytical method to determine the absolute configuration of the separated enantiomers. When comparing the measured IR (infrared) and VCD spectra, it is apparent that the amide carbonyl groups appear in the IR but are nearly absent in the VCD. Computational work to calculate the VCD and IR using in vacuo models, implicit solvation, and explicitly solvated complexes has implicated conformational averaging of the carbonyl VCD intensities. © 2017 Wiley Periodicals, Inc.

  15. Absolute efficiencies of X-ray screens for fluoroscopy

    International Nuclear Information System (INIS)

    Giakoumakis, G.E.

    1989-01-01

    The absolute X-ray efficiencies of phosphor screens made of various materials (ZnCdS:Ag, CsI:Na, Y 2 O 2 S:Tb, Gd 2 O 2 S:Tb, CaWO 4 and ZnS:Cu) are reported. The measurements have been carried out under fluoroscopic conditions for tube voltages ranging from 50 to 250 kV and for screen weights from 20 to 200 mg cm -2 . There is also, for comparison, a set of measurements concerning the behaviour of the screens under soft X-rays (20-50 kV) excitation. All the experimental results are discussed on the basis of an improved Hammaker-Ludwig model and analytical expressions are presented permitting the theoretical calculation of the absolute efficiency of the screens. (author)

  16. Absolute dating of the Aegean Late Bronze Age

    International Nuclear Information System (INIS)

    Warren, P.M.

    1987-01-01

    A recent argument for raising the absolute date of the beginning of the Aegean Late Bronze (LB) Age to about 1700 B.C. is critically examined. It is argued here that: (1) the alabaster lid from Knossos did have the stratigraphical context assigned to it by Evans, in all probability Middle Minoan IIIA, c. 1650 B.C.; (2) the attempt to date the alabastron found in an early Eighteenth Dynasty context at Aniba to Late Minoan IIIA:1 is open to objections; (3) radiocarbon dates from Aegean LB I contexts are too wide in their calibrated ranges and too inconsistent both within and between site sets to offer any reliable grounds at present for raising Aegean LB I absolute chronology to 1700 B.C. Other evidence, however, suggests this period began about 1600 B.C., i.e. some fifty years earlier than the conventional date of 1550 B.C. (author)

  17. Absolute limit on rotation of gravitationally bound stars

    Science.gov (United States)

    Glendenning, N. K.

    1994-03-01

    The authors seek an absolute limit on the rotational period for a neutron star as a function of its mass, based on the minimal constraints imposed by Einstein's theory of relativity, Le Chatelier's principle, causality, and a low-density equation of state, uncertainties which can be evaluated as to their effect on the result. This establishes a limiting curve in the mass-period plane below which no pulsar that is a neutron star can lie. For example, the minimum possible Kepler period, which is an absolute limit on rotation below which mass-shedding would occur, is 0.33 ms for a M = 1.442 solar mass neutron star (the mass of PSR1913+16). If the limit were found to be broken by any pulsar, it would signal that the confined hadronic phase of ordinary nucleons and nuclei is only metastable.

  18. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  19. Absolute scale-based imaging position encoder with submicron accuracy

    Science.gov (United States)

    Anisimov, Andrey G.; Pantyushin, Anton V.; Lashmanov, Oleg U.; Vasilev, A. S.; Timofeev, Alexander N.; Korotaev, Valery V.; Gordeev, Sergey V.

    2013-04-01

    Study is devoted to experimental research and development of absolute imaging position encoder based on standard calibrated scale of invar alloy with 1 mm spacing. The encoder uses designed imaging system as a vernier and absolute magnetic encoder as a rough indication. The features of optical design, choice and use of imaging system as long as indexes images processing algorithm are described. A shadow method was implemented: indexes images on a CCD array are formed by the lens focused at the scale surface; the laser module lights up the scale through a beam-splitting prism by a parallel beam. Further dark indexes images on a light scale background are detected and analyzed to estimate the encoder position. Full range of experimental tests was set to calibrate the encoder and to estimate the accuracy. As a result, accuracy close to 1 μm at 1 m was achieved.

  20. ABSOLUTE AND COMPARATIVE SUSTAINABILITY OF FARMING ENTERPRISES IN BULGARIA

    Directory of Open Access Journals (Sweden)

    H. Bachev

    2017-04-01

    Full Text Available Evaluating absolute and comparative sustainability of farming enterprises is among the most topical issues for researchers, farmers, investors, administrators, politicians, interests groups and public at large. Nevertheless, in Bulgaria and most East European countries there are no comprehensive assessments on sustainability level of Bulgarian farms of different juridical type. This article applies a holistic framework and assesses absolute and comparative sustainability major farming structures in Bulgaria - unregistered farms of Natural Persons, Sole Traders, Cooperatives, and Companies. First, method of the study is outlined, and overall characteristics of surveyed farming enterprises presented. After that an assessment is made of integral, governance, economic, social, environmental sustainability of farming structures of different juridical type. Next, structure of farming enterprises with different sustainability levels is analyzed. Finally, conclusion from the study and directions for further research and amelioration of sustainability assessments suggested.

  1. Absolute bunch length measurements by incoherent radiation fluctuation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Stupakov, Gennady; Zolotorev, Max; Filippetto, Daniele; Jagerhofer, Lukas

    2008-09-29

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  2. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; /LBL, Berkeley; Stupakov, G.V.; /SLAC; Zolotorev, M.S.; /LBL, Berkeley; Filippetto, D.; /INFN, Rome; Jagerhofer, L.; /Vienna, Tech. U.

    2009-12-09

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  3. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  4. Purely absolutely continuous spectrum for almost Mathieu operators

    International Nuclear Information System (INIS)

    Chulaevsky, V.; Delyon, F.

    1989-01-01

    Using a recent result of Sinai, the authors prove that the almost Mathieu operators acting on l 2 (Z), (H αλ Psi)(n) = Ψ(n + 1) + Ψ(n - 1) + λ cos(ωn + α) Ψ(n), have a purely absolutely continuous spectrum for almost all α provided that ω is a good irrational and λ is sufficiently small. Furthermore, the generalized eigenfunctions are quasiperiodic

  5. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    International Nuclear Information System (INIS)

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1 rc covering ∼2600-3300 A after removing optical light, and u ∼ 3000-4000 A) compared to a mid-UV filter (uvm2 ∼2000-2400 A). The uvw1 rc - b colors show a scatter of ∼0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, ∼1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  6. Decreasing Absolute Risk Aversion and Option Pricing Bounds

    OpenAIRE

    Antonella Basso; Paolo Pianca

    1997-01-01

    In this paper efficient bounds for the price of a call option are obtained using the decreasing absolute risk aversion (DARA) dominance rule. Such lower and upper bounds are obtained minimizing and maximizing, respectively, the objective function of a nonlinear optimization problem. An explicit formula (related to an exponential utility function) is given for the special case of three states of nature. A large number of experiments have been carried out and the numerical results support the c...

  7. On the Plane Geometry with Generalized Absolute Value Metric

    Directory of Open Access Journals (Sweden)

    A. Bayar

    2008-01-01

    Full Text Available Metric spaces are among the most important widely studied topics in mathematics. In recent years, Mathematicians began to investigate using other metrics different from Euclidean metric. These metrics also find their place computer age in addition to their importance in geometry. In this paper, we consider the plane geometry with the generalized absolute value metric and define trigonometric functions and norm and then give a plane tiling example for engineers underlying Schwarz's inequality in this plane.

  8. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  9. Making Astrology Scientific with Negative Absolute Temperature and Holography

    OpenAIRE

    Bartlett, Rodney

    2016-01-01

    This article was written after reading Astronomy magazine's column "Strange Universe" by Bob Berman. Toeing the traditional line of his fellow astronomers, he claims astrology is just a bit of fun, and that it has no scientific support. If we only focus on today's science, he's spot on - it has no support. But I refer to some science involving holograms and negative absolute temperatures to show that astrology would have scientific support in a new science based on cosmic unification, it w...

  10. Absolute Pitch: Effects of Timbre on Note-Naming Ability

    OpenAIRE

    Vanzella, Patr?cia; Schellenberg, E. Glenn

    2010-01-01

    Background Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP poss...

  11. Blastic plasmacytoid dendritic cell neoplasm with absolute monocytosis at presentation

    Directory of Open Access Journals (Sweden)

    Jaworski JM

    2015-02-01

    Full Text Available Joseph M Jaworski,1,2 Vanlila K Swami,1 Rebecca C Heintzelman,1 Carrie A Cusack,3 Christina L Chung,3 Jeremy Peck,3 Matthew Fanelli,3 Micheal Styler,4 Sanaa Rizk,4 J Steve Hou1 1Department of Pathology and Laboratory Medicine, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 2Department of Pathology, Mercy Fitzgerald Hospital, Darby, PA, USA; 3Department of Dermatology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA; 4Department of Hematology/Oncology, Hahnemann University Hospital/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Blastic plasmacytoid dendritic cell neoplasm is an uncommon malignancy derived from precursors of plasmacytoid dendritic cells. Nearly all patients present initially with cutaneous manifestations, with many having extracutaneous disease additionally. While response to chemotherapy initially is effective, relapse occurs in most, with a leukemic phase ultimately developing. The prognosis is dismal. While most of the clinical and pathologic features are well described, the association and possible prognostic significance between peripheral blood absolute monocytosis (>1.0 K/µL and blastic plasmacytoid dendritic cell neoplasm have not been reported. We report a case of a 68-year-old man who presented with a rash for 4–5 months. On physical examination, there were multiple, dull-pink, indurated plaques on the trunk and extremities. Complete blood count revealed thrombocytopenia, absolute monocytosis of 1.7 K/µL, and a negative flow cytometry study. Biopsy of an abdominal lesion revealed typical features of blastic plasmacytoid dendritic cell neoplasm. Patients having both hematologic and nonhematologic malignancies have an increased incidence of absolute monocytosis. Recent studies examining Hodgkin and non-Hodgkin lymphoma patients have suggested that this is a negative prognostic factor. The association between

  12. Absolute Stock Returns and Trading Volumes: Psychological Insights

    Directory of Open Access Journals (Sweden)

    Andrey Kudryavtsev

    2017-07-01

    Full Text Available The present study explores the effect of anchoring on stock trading volumes. I hypothesize that if on the days when the market index rises (falls, a given stock's return is higher (lower than the market return, potentially perceived as a psychological "anchor", then investors may treat that as a salient event and subsequently increase their trading activity in the stock. Employing a large sample of daily price and trading volume data, I find support for this hypothesis, documenting that average abnormal daily stock trading volumes are significantly higher on the days when absolute daily stock returns are higher than the contemporaneous absolute market returns. This effect is found to be stronger on the days of negative stock and market returns, suggesting that on these days, investors are probably more inclined to treat the market returns as anchors when making their trading decisions. The effect remains significant after controlling for other potentially influential factors, including contemporaneous and lagged actual and absolute stock and market returns, historical stock returns and volatilities, and company-specific events, like earnings announcements and dividend payments.

  13. A vibration correction method for free-fall absolute gravimeters

    Science.gov (United States)

    Qian, J.; Wang, G.; Wu, K.; Wang, L. J.

    2018-02-01

    An accurate determination of gravitational acceleration, usually approximated as 9.8 m s-2, has been playing an important role in the areas of metrology, geophysics, and geodetics. Absolute gravimetry has been experiencing rapid developments in recent years. Most absolute gravimeters today employ a free-fall method to measure gravitational acceleration. Noise from ground vibration has become one of the most serious factors limiting measurement precision. Compared to vibration isolators, the vibration correction method is a simple and feasible way to reduce the influence of ground vibrations. A modified vibration correction method is proposed and demonstrated. A two-dimensional golden section search algorithm is used to search for the best parameters of the hypothetical transfer function. Experiments using a T-1 absolute gravimeter are performed. It is verified that for an identical group of drop data, the modified method proposed in this paper can achieve better correction effects with much less computation than previous methods. Compared to vibration isolators, the correction method applies to more hostile environments and even dynamic platforms, and is expected to be used in a wider range of applications.

  14. Bio-Inspired Stretchable Absolute Pressure Sensor Network.

    Science.gov (United States)

    Guo, Yue; Li, Yu-Hung; Guo, Zhiqiang; Kim, Kyunglok; Chang, Fu-Kuo; Wang, Shan X

    2016-01-02

    A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4'' wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles.

  15. Philosophy as Inquiry Aimed at the Absolute Knowledge

    Directory of Open Access Journals (Sweden)

    Ekaterina Snarskaya

    2017-09-01

    Full Text Available Philosophy as the absolute knowledge has been studied from two different but closely related approaches: historical and logical. The first approach exposes four main stages in the history of European metaphysics that marked out types of “philosophical absolutism”: the evolution of philosophy brought to light metaphysics of being, method, morals and logic. All of them are associated with the names of Aristotle, Bacon/Descartes, Kant and Hegel. Then these forms are considered in the second approach that defined them as subject-matter of philosophy as such. Due to their overall, comprehensive character, the focus of philosophy on them justifies its claim on absoluteness as far as philosophy is aimed at comprehension of the world’s unity regardless of the philosopher’s background, values and other preferences. And that is its prerogative since no other form of consciousness lays down this kind of aim. Thus, philosophy is defined as an everlasting attempt to succeed in conceiving the world in all its multifold manifestations. This article is to try to clarify the claim of philosophy on the absolute knowledge.

  16. Use of intensity quotients and differences in absolute structure refinement

    International Nuclear Information System (INIS)

    Parsons, Simon; Flack, Howard D.; Wagner, Trixie

    2013-01-01

    Differences and quotients can be defined using Friedel pairs of reflections and applied in refinement to enable absolute structure to be determined precisely even for light atom crystal structures. Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement

  17. Absolutely minimal extensions of functions on metric spaces

    International Nuclear Information System (INIS)

    Milman, V A

    1999-01-01

    Extensions of a real-valued function from the boundary ∂X 0 of an open subset X 0 of a metric space (X,d) to X 0 are discussed. For the broad class of initial data coming under discussion (linearly bounded functions) locally Lipschitz extensions to X 0 that preserve localized moduli of continuity are constructed. In the set of these extensions an absolutely minimal extension is selected, which was considered before by Aronsson for Lipschitz initial functions in the case X 0 subset of R n . An absolutely minimal extension can be regarded as an ∞-harmonic function, that is, a limit of p-harmonic functions as p→+∞. The proof of the existence of absolutely minimal extensions in a metric space with intrinsic metric is carried out by the Perron method. To this end, ∞-subharmonic, ∞-superharmonic, and ∞-harmonic functions on a metric space are defined and their properties are established

  18. Absolute activity determination of I-125 in the thyroid

    International Nuclear Information System (INIS)

    Pelled, O.; German, U.; Kol, R.; Levinson, S.; Laichter, Y.

    1997-01-01

    I-125 has been widely used in nuclear medicine and as a tracer in different experiments. The dose equivalent to the thyroid Tom internal contamination of 1-125, can be estimated by in-vivo monitoring of the thyroid or through bioassay of urine . The in-vivo monitoring of the thyroid can be carried out by counting the photon emission from the decay of the 1-125 , by a Nal(Tl) detector calibrated with a thyroid phantom. This direct method is sensitive , but due to the low photon energy (27keV to 35keV), the counting efficiency depends strongly on the variations of the thyroid mass , thyroid depth below the surface , thyroid shape and detector position . It is estimated that the uncertainty of the activity determination can reach several hundred percents . A mewed for absolute determination of the activity of a '251 source based on the counting rate values of file 27 keV photons and the 54 keV coincidence photo peak, which diminishes the geometry dependence of the counting efficiency , was applied to determine the uptake of 125-I in human thyroid In this work we checked also the application of the absolute determination method wife high sensitivity phoswich detectors. We compare the results of calculations of interval exposure to 125-I for a real case, evaluated by the absolute determination method and by the direct method. (authors)

  19. 242Pu absolute neutron-capture cross section measurement

    Science.gov (United States)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.

    2017-09-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ) cross section could be set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ) cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ) En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ) cross section.

  20. 242Pu absolute neutron-capture cross section measurement

    Directory of Open Access Journals (Sweden)

    Buckner M.Q.

    2017-01-01

    Full Text Available The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ cross section could be set according to the known 239Pu(n,f resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ cross section.

  1. Overspecification of colour, pattern, and size: Salience, absoluteness, and consistency

    Directory of Open Access Journals (Sweden)

    Sammie eTarenskeen

    2015-11-01

    Full Text Available The rates of overspecification of colour, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Colour and pattern are absolute attributes, whereas size is relative and less salient. Additionally, a tendency towards consistent responses is assessed. Using a within-participants design, we find similar rates of colour and pattern overspecification, which are both higher than the rate of size overspecification. Using a between-participants design, however, we find similar rates of pattern and size overspecification, which are both lower than the rate of colour overspecification. This indicates that although many speakers are more likely to include colour than pattern (probably because colour is more salient, they may also treat pattern like colour due to a tendency towards consistency. We find no increase in size overspecification when the salience of size is increased, suggesting that speakers are more likely to include absolute than relative attributes. However, we do find an increase in size overspecification when mentioning the attributes is triggered, which again shows that speakers tend refer in a consistent manner, and that there are circumstances in which even size overspecification is frequently produced.

  2. The new Absolute Quantum Gravimeter (AQG): first results and perspectives

    Science.gov (United States)

    Bonvalot, Sylvain; Le Moigne, Nicolas; Merlet, Sebastien; Desruelle, Bruno; Lautier-Gaud, Jean; Menoret, Vincent; Vermeulen, Pierre

    2016-04-01

    Cold atom gravimetry represents one of the most innovative evolution in gravity instrumentation since the last 20 years. The concept of measuring the gravitational acceleration by dropping atoms and the development of the first instrumental devices during this last decade quickly revealed the promising perspectives of this new generation of gravity meters enabling accurate and absolute measurements of the Earth's gravity field for a wide range of applications (geophysics, geodesy, metrology, etc.). The Absolute Quantum Gravimeter (AQG) gravity meter, developed by MUQUANS (Talence, France - http://www.muquans.com/) with the support of RESIF, the French Seismologic and Geodetic Network (http://www.resif.fr/) belongs to this new generation of instruments. It also represents the first commercial device based on the utilization of advanced matter-wave interferometry techniques, which allow to characterize precisely the vertical acceleration experienced by a cloud of cold atoms. Recently, the first operational unit (AQG01) has been achieved as a compact transportable gravimeter with the aim of satisfying absolute gravity measurements in laboratory conditions under the following specifications: measurements the μGal level at a few Hz cycling frequency, sensitivity of 50μGal/√Hz, immunity to ground vibrations, easy and quickness of operation, automated continuous data acquisition for several months, etc. In order to evaluate the current performances of the AQG01, several experiments are carried out in collaboration between RESIF user's teams and the MUQUANS manufacturer on different reference gravity sites and laboratories in France. These measurements performed in indoor conditions including simultaneous observations with classical reference gravity instruments (corner-cube absolute gravity meters, relative superconducting meters) as well with the Cold Atom Gravity meter (CAG) developed by LNE-SYRTE, lead to a first objective characterization of the performances of

  3. Consequences count: against absolutism at the end of life.

    Science.gov (United States)

    Snelling, Paul C

    2004-05-01

    There has been a considerable amount of debate in the nursing literature about euthanasia, and especially the distinctions between acts and omissions, and killing and letting die. These distinctions are required by opponents of euthanasia to justify allowing some cases of passive euthanasia while forbidding all cases of active euthanasia. This paper adds to the debate by arguing that the position that absolutely forbids euthanasia is theoretically inconsistent. The paper first considers the place of moral theory in analysing moral problems, within the framework of the principles of biomedical ethics. It is argued that despite a moral pluralism that operates in many areas, the legal status of euthanasia is based upon an absolute deontological position against deliberate killing, which cannot be overridden by appeals to favourable consequences. In order that certain forms of passive euthanasia can be allowed, this position allows distinctions within three pairs of concepts--acts and omissions, killing and letting die, and ordinary and extraordinary means. A further method of justifying certain actions near the end of life is the doctrine of double effect. These paired concepts and the doctrine of double effect are analysed with special reference to their consequences. The application of the doctrine of double effect and the three distinctions relies on consideration of their consequences, allowing in practice what in theory is denied. This is important because it weakens the absolute case against euthanasia, which disallows any direct consequentialist appeal. If consequences count in the application of the doctrine and the distinctions, then they should also count directly prior to their application. This strengthens the argument for active euthanasia in certain cases.

  4. Automated absolute activation analysis with californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg /sup 252/Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from /sup 17/O. Detection sensitivities of < or = 400 ppB for natural uranium and 8 ppB (< or = 0.5 (nCi/g)) for /sup 239/Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level.

  5. Absolute Memory for Tempo in Musicians and Non-Musicians.

    Science.gov (United States)

    Gratton, Irene; Brandimonte, Maria A; Bruno, Nicola

    2016-01-01

    The ability to remember tempo (the perceived frequency of musical pulse) without external references may be defined, by analogy with the notion of absolute pitch, as absolute tempo (AT). Anecdotal reports and sparse empirical evidence suggest that at least some individuals possess AT. However, to our knowledge, no systematic assessments of AT have been performed using laboratory tasks comparable to those assessing absolute pitch. In the present study, we operationalize AT as the ability to identify and reproduce tempo in the absence of rhythmic or melodic frames of reference and assess these abilities in musically trained and untrained participants. We asked 15 musicians and 15 non-musicians to listen to a seven-step `tempo scale' of metronome beats, each associated to a numerical label, and then to perform two memory tasks. In the first task, participants heard one of the tempi and attempted to report the correct label (identification task), in the second, they saw one label and attempted to tap the correct tempo (production task). A musical and visual excerpt was presented between successive trials as a distractor to prevent participants from using previous tempi as anchors. Thus, participants needed to encode tempo information with the corresponding label, store the information, and recall it to give the response. We found that more than half were able to perform above chance in at least one of the tasks, and that musical training differentiated between participants in identification, but not in production. These results suggest that AT is relatively wide-spread, relatively independent of musical training in tempo production, but further refined by training in tempo identification. We propose that at least in production, the underlying motor representations are related to tactus, a basic internal rhythmic period that may provide a body-based reference for encoding tempo.

  6. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  7. Absolute versus relative ascertainment of pedophilia in men.

    Science.gov (United States)

    Blanchard, Ray; Kuban, Michael E; Blak, Thomas; Cantor, James M; Klassen, Philip E; Dickey, Robert

    2009-12-01

    There are at least two different criteria for assessing pedophilia in men: absolute ascertainment (their sexual interest in children is intense) and relative ascertainment (their sexual interest in children is greater than their interest in adults). The American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, 3rd edition (DSM-III) used relative ascertainment in its diagnostic criteria for pedophilia; this was abandoned and replaced by absolute ascertainment in the DSM-III-R and all subsequent editions. The present study was conducted to demonstrate the continuing need for relative ascertainment, particularly in the laboratory assessment of pedophilia. A total of 402 heterosexual men were selected from a database of patients referred to a specialty clinic. These had undergone phallometric testing, a psychophysiological procedure in which their penile blood volume was monitored while they were presented with a standardized set of laboratory stimuli depicting male and female children, pubescents, and adults.The 130 men selected for the Teleiophilic Profile group responded substantially to prepubescent girls but even more to adult women; the 272 men selected for the Pedophilic Profile group responded weakly to prepubescent girls but even less to adult women. In terms of absolute magnitude, every patient in the Pedophilic Profile group had a lesser penile response to prepubescent girls than every patient in the Teleiophilic Profile group. Nevertheless, the Pedophilic Profile group had a significantly greater number of known sexual offenses against prepubescent girls, indicating that they contained a higher proportion of true pedophiles. These results dramatically demonstrate the utility-or perhaps necessity-of relative ascertainment in the laboratory assessment of erotic age-preference.

  8. Absolute dating methods for the Southern African Cainozoic

    Energy Technology Data Exchange (ETDEWEB)

    Patridge, T.C. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Anatomy); Netterburg, F. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Inst. for Transport and Road Research); Vogel, J.C. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Physical Research Lab.); Sellschop, J.P.F. (University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit)

    1984-09-01

    Those absolute dating methods other than radiocarbon which appear most useful for the Southern African Cainozoic are uranium disequilibrium, amino acid racemization, thermoluminescence, electron spin resonance, potassium/argon, and accelerator mass spectrometry. Although they are comparative dating methods only, the palaeo- and archaeomagnetic techniques appear most promising. More than one method is necessary to cover the ages and types of Southern African materials. The need for local dating services justifies the establishment of further Cainozoic dating facilities in South Africa. The necessary equipment is already available, or could be developed by adapting existing apparatus, so that only additional staff and funding would be required.

  9. Absolute distance measurements using two-mode laser telemetry

    Science.gov (United States)

    Lintz, Michel.; Courde, C.; Brillet, A.; Man, C. N.

    2017-11-01

    A novel laser ranging method is described that uses a two-mode laser source, and detection of the phase of the return beam. The design eliminates the cyclic error usually associated with phase measurements and provides unambiguous, absolute distance determination. Measurements of an ≍ 8m path are obtained at a beat frequency of 13 GHz. We analyse the ≍1 μm stability of the data obtained with this preliminary implementation, and expect that an improved version will allow accuracies well below 1 μm, for the kilometer-scale distances involved in satellite formation flight.

  10. Absolute nondestructive quantitative determination of uranium in special nuclear materials

    International Nuclear Information System (INIS)

    Dragnev, T.; Damyanov, B.; Grozev, G.; Karamanova, J.

    1985-01-01

    An absolute nondestructive method for quantitative measurement of uranium concentration and enrichment in special nuclear materials is proposed. The method uses intrinsic calibration and portable instrumentation and the particularly suitable for IAEA safequards applications. The intrinsic calibration accumulates the positive experience of the previous measurements and the results will be continuously improving. It is possible to measure standards in laboratories and use the results for analysis at different time and places. The tests show a good agreement with known classical methods and better results in some cases

  11. The absolute energy flux envelopes of B type stars.

    Science.gov (United States)

    Underhill, A. B.

    1972-01-01

    Absolute energy flux envelopes covering the region of 1100 to 6000 A for main-sequence stars of types B3, B7 and A0 derived from published, ground-based observations and from spectrum scans with OAO-II are presented. These flux envelopes are compared with the predicted flux envelopes from lightly line-blanketed model atmospheres. The line blanketing at wavelengths shorter than 3000 A is severe, about one-half the predicted light being observed at 1600 A. These results demonstrate that a model which represents well the observed visible spectrum of a star may fail seriously for representing the ultraviolet spectrum.

  12. Absolute gravimetry on the agulhas negras calibration line

    OpenAIRE

    Sousa, Mauro Andrade de; Santos, Alcides Antonio dos

    2010-01-01

    The Agulhas Negras Gravity Calibration Line was established in the mid 1980s using LaCoste & Romberg gravimeters model "G" only. Five gravity stations were irregularly positioned along its 200 km length, spanning a total range of 627 mGal. The new absolute gravimeter Micro-g Solutions A-10 #011 of Observatório Nacional was taken to each calibration station and new measurements were made. The local vertical gravity gradient was also measured at each calibration station. This report shows their...

  13. Absolute Mass Scale Calibration Using Z->mumu

    CERN Document Server

    Aleksa, Martin

    1999-01-01

    Detailed simulations have been performed, investigating the possibility of calibrating the absolute mass scale of the muon spectrometer by using Z->mumu A sample of 10000 events was processed through DICE/ATRECON applying different scale factors to the magnetic field as a function of phi and eta. It is shown that these scale factors could be retrieved with high accuracy together with the muon energy loss as a function of eta. It is shown that the energy loss in the barrel region could be found with an accuracy of 45 MeV while calibrating at the same time 2 magnetic field scale factors with an accuracy of 0.001.

  14. Quantum bath refrigeration towards absolute zero: challenging the unattainability principle.

    Science.gov (United States)

    Kolář, M; Gelbwaser-Klimovsky, D; Alicki, R; Kurizki, G

    2012-08-31

    A minimal model of a quantum refrigerator, i.e., a periodically phase-flipped two-level system permanently coupled to a finite-capacity bath (cold bath) and an infinite heat dump (hot bath), is introduced and used to investigate the cooling of the cold bath towards absolute zero (T=0). Remarkably, the temperature scaling of the cold-bath cooling rate reveals that it does not vanish as T→0 for certain realistic quantized baths, e.g., phonons in strongly disordered media (fractons) or quantized spin waves in ferromagnets (magnons). This result challenges Nernst's third-law formulation known as the unattainability principle.

  15. Exponential bound in the quest for absolute zero

    Science.gov (United States)

    Stefanatos, Dionisis

    2017-10-01

    In most studies for the quantification of the third law of thermodynamics, the minimum temperature which can be achieved with a long but finite-time process scales as a negative power of the process duration. In this article, we use our recent complete solution for the optimal control problem of the quantum parametric oscillator to show that the minimum temperature which can be obtained in this system scales exponentially with the available time. The present work is expected to motivate further research in the active quest for absolute zero.

  16. An Algorithm for Solving the Absolute Value Equation

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří

    2009-01-01

    Roč. 18, - (2009), s. 589-599 E-ISSN 1081-3810 R&D Projects: GA ČR GA201/09/1957; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : absolute value equation * algorithm * regularity * singularity * theorem of the alternatives Subject RIV: BA - General Mathematics Impact factor: 0.892, year: 2009 http://www.math.technion.ac.il/iic/ ela / ela -articles/articles/vol18_pp589-599.pdf

  17. Absolute coverage of the saturated cesium silicon interfaces

    Science.gov (United States)

    Sherman, William Benjamin

    Metal/semiconductor interfaces are of great interest for a variety of reasons. They shed light on surface metal/semiconductor transitions, and they form Schottky barriers, which are of scientific as well as significant technological importance (primarily for the production of high speed, low-power logic circuitry). The cesium/silicon interfaces are of particular interest since the oxide forms a Negative Electron Affinity state. Cesium does not mix with the bulk silicon, so the interface is very abrupt, and the electronic structure of cesium is easier to understand than that of the transition metals. Further, cesium (like other alkali metals at room temperature) forms a single atomic layer on the various silicon faces and then the coverage saturates (i.e. atoms stop sticking to the surface). This makes the cesium/silicon interfaces ideal model systems of the metal/semiconductor interface. In spite of their importance, the detailed structures of the cesium saturated silicon faces are still uncertain. Numerous structural models have been proposed and many of them have quite different absolute coverages. Thus absolute coverage measurements can effectively distinguish between the various models. Rutherford Backscattering Spectrometry (RBS) provides an ideal measurement of absolute coverage since its results can be directly interpreted without dependence upon any structural model. A new beam line has been set up on the Laboratory for Research on the Structure of Matter's tandem accelerator. The Ultrahigh Vacuum system is equipped with an Auger Electron Spectrometer, a Low Energy Electron Diffraction system, a retarding field method work function analyzer, a cesium doser, a Medium Energy Ion Scattering two dimensional toroidal analyzer and a Rutherford Backscattering: Spectrometry (RBS) solid state ion detector. It has been used to manufacture saturated Cs/Si(100)-2 x 1 and Cs/Si(111)-7 x 7 interfaces and measure their absolute coverage via RBS. The coverage for the Si

  18. Optimal quantum error correcting codes from absolutely maximally entangled states

    Science.gov (United States)

    Raissi, Zahra; Gogolin, Christian; Riera, Arnau; Acín, Antonio

    2018-02-01

    Absolutely maximally entangled (AME) states are pure multi-partite generalizations of the bipartite maximally entangled states with the property that all reduced states of at most half the system size are in the maximally mixed state. AME states are of interest for multipartite teleportation and quantum secret sharing and have recently found new applications in the context of high-energy physics in toy models realizing the AdS/CFT-correspondence. We work out in detail the connection between AME states of minimal support and classical maximum distance separable (MDS) error correcting codes and, in particular, provide explicit closed form expressions for AME states of n parties with local dimension \

  19. Absolute configuration of verticillane diterpenoids by vibrational circular dichroism.

    Science.gov (United States)

    Cerda-García-Rojas, Carlos M; García-Gutiérrez, Hugo A; Hernandez-Hernandez, Juan D; Roman-Marín, Luisa U; Joseph-Nathan, Pedro

    2007-07-01

    Good agreement between theoretical and experimental vibrational circular dichroism curves of (1S,11S,12S)-(+)-verticilla-3E,7E-dien-12-ol (1) established the absolute configuration of this natural diterpene isolated from Bursera suntui. Molecular modeling of 1 was carried out using the Monte Carlo protocol followed by geometry optimization at the B3LYP 6-31G(d,p) level of theory. The 12-membered ring of 1 was found in a single preferred chair-chair-chair-chair conformation. In the six-membered ring a chair prevails over a distorted boat, and the C-OH bond rotation generates three predominant rotamers. Validation of the minimum energy conformation for 1 was achieved by comparison of theoretical and experimental infrared frequencies, vicinal 1H NMR coupling constants, and X-ray diffraction data. This study confirms that (+)-verticillol 1 isolated from Bursera species has the 1S,11S,12S absolute configuration that corresponds to the same enantiomeric series as verticillanes from Sciadopitys and Taxus, while verticillanes from Jackiella and Jungermannia have antipodal structures.

  20. The Determination of Absolute Sea level Rise in New Zealand

    Science.gov (United States)

    Hannah, J.; Denys, P. H.; Beavan, R. J.

    2010-12-01

    Long term sea level trends at five New Zealand tide gauges with records > 60 yr in length have been determined through to the end of 2008. These gauges, with a wide spatial distribution, reveal an average relative sea level rise across of 1.7 ± 0.1 mm/yr. When a Glacial Isostatic adjustment (GIA) is applied using Peltier’s ICE 5G (v1.2) model, this estimated trend rises to 2.0 mm/yr. However, the absolute trends, when calculated using approximately 10 years of cGPS data at the four gauges with the longest records (Auckland, Wellington, Lyttelton and Dunedin), show a sea level rise of only 1.2 ± 0.4 mm/yr. If the Wellington gauge (located in the transitional plate boundary zone) is removed, this absolute trend rises to 1.4 mm/yr. This paper outlines how the above results were obtained and discusses proposed future research directions. It also includes previously unpublished data on relative sea level trends as determined at a further four New Zealand tide gauge sites.

  1. PROFIT AND LOSS ACCOUNT – SYNTHETIC EXPRESSION OF ABSOLUTE RETURN

    Directory of Open Access Journals (Sweden)

    MIRON VASILE CRISTIAN IOACHIM

    2017-08-01

    Full Text Available This study has as main objective the presentation of the current state of knowledge regarding the profit and loss account as part of the financial statements which express in absolute value the profitability of companies and the empirical analysis of these concepts based on the information submitted by OMV Petrom between 2011 and 2015. Thus, in the first part we present several approaches from the specialized literature regarding the aspects mentioned above. The second part follows a vertical and horizontal analysis of key indicators used for measuring the absolute return. For the horizontal analysis we pursued the evolution in time of the following indicators: Gross Margin, Earnings Before Interest and Taxes (EBIT, Financial Result, Gross and Net Result. The vertical analysis aimed to explain the formation of the Gross Result via EBIT (which was also analyzed through the Gross Margin and other specific elements and of the Financial Result (which was also analyzed through the different types of financial income and expenses. The results of the study revealed problems of profitability in the years 2014 and 2015 which, in our opinion, can be attributed to poor management of the commercial activity, exploration activity (research and development, distribution and financial activity.

  2. Use of intensity quotients and differences in absolute structure refinement

    Science.gov (United States)

    Parsons, Simon; Flack, Howard D.; Wagner, Trixie

    2013-01-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  3. Absolute measurements of chlorine Cl+ cation single photoionization cross section

    International Nuclear Information System (INIS)

    Hernández, E.M.; Juárez, A.M.; Kilcoyne, A.L.D.; Aguilar, A.; Hernández, L.; Antillón, A.; Macaluso, D.; Morales-Mori, A.; González-Magaña, O.; Hanstorp, D.; Covington, A.M.; Davis, V.; Calabrese, D.; Hinojosa, G.

    2015-01-01

    The photoionization of Cl + leading to Cl 2+ was measured in the photon energy range of 19.5–28.0 eV. A spectrum with a photon energy resolution of 15 meV normalized to absolute cross-section measurements is presented. The measurements were carried out by merging a Cl + ion beam with a photon beam of highly monochromatic synchrotron radiation at the Advanced Light Source at Lawrence Berkeley National Laboratory. The measured photoionization of Cl + consists of several autoionization resonances surperimposed on the direct photoionization signal. Most of the prominent resonances are assigned to members of Rydberg series originating from the singlet ground state and from metastable triplet levels within the ground-state configuration of Cl + . The direct ionization cross section is no larger than 12 Mb. - Highlights: • The single photoionization absolute cross section of Cl + ion was measured. • Numerous resonances were identified as belonging to Rydberg series. • A large population of the metastable Cl + ( 1 D 2 ) was identified. • Identified resulting Cl 2+ state terms correspond to 2 D 5/2 and 2 D 3/2

  4. Absolute values of neutrino masses: status and prospects

    International Nuclear Information System (INIS)

    Bilenky, S.M.; Giunti, C.; Grifols, J.A.; Masso, E.

    2003-01-01

    Compelling evidences in favor of neutrino masses and mixing obtained in the last years in Super-Kamiokande, SNO, KamLAND and other neutrino experiments made the physics of massive and mixed neutrinos a frontier field of research in particle physics and astrophysics. There are many open problems in this new field. In this review we consider the problem of the absolute values of neutrino masses, which apparently is the most difficult one from the experimental point of view. We discuss the present limits and the future prospects of β-decay neutrino mass measurements and neutrinoless double-β decay. We consider the important problem of the calculation of nuclear matrix elements of neutrinoless double-β decay and discuss the possibility to check the results of different model calculations of the nuclear matrix elements through their comparison with the experimental data. We discuss the upper bound of the total mass of neutrinos that was obtained recently from the data of the 2dF Galaxy Redshift Survey and other cosmological data and we discuss future prospects of the cosmological measurements of the total mass of neutrinos. We discuss also the possibility to obtain information on neutrino masses from the observation of the ultra high-energy cosmic rays (beyond the GZK cutoff). Finally, we review the main aspects of the physics of core-collapse supernovae, the limits on the absolute values of neutrino masses from the observation of SN1987A neutrinos and the future prospects of supernova neutrino detection

  5. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  6. Improved Strategies and Optimization of Calibration Models for Real-time PCR Absolute Quantification

    Science.gov (United States)

    Real-time PCR absolute quantification applications rely on the use of standard curves to make estimates of DNA target concentrations in unknown samples. Traditional absolute quantification approaches dictate that a standard curve must accompany each experimental run. However, t...

  7. Regional absolute conductivity reconstruction using projected current density in MREIT

    International Nuclear Information System (INIS)

    Sajib, Saurav Z K; Kim, Hyung Joong; Woo, Eung Je; Kwon, Oh In

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a non-invasive technique for imaging the internal conductivity distribution in tissue within an MRI scanner, utilizing the magnetic flux density, which is introduced when a current is injected into the tissue from external electrodes. This magnetic flux alters the MRI signal, so that appropriate reconstruction can provide a map of the additional z-component of the magnetic field (B z ) as well as the internal current density distribution that created it. To extract the internal electrical properties of the subject, including the conductivity and/or the current density distribution, MREIT techniques use the relationship between the external injection current and the z-component of the magnetic flux density B = (B x , B y , B z ). The tissue studied typically contains defective regions, regions with a low MRI signal and/or low MRI signal-to-noise-ratio, due to the low density of nuclear magnetic resonance spins, short T 2 or T* 2 relaxation times, as well as regions with very low electrical conductivity, through which very little current traverses. These defective regions provide noisy B z data, which can severely degrade the overall reconstructed conductivity distribution. Injecting two independent currents through surface electrodes, this paper proposes a new direct method to reconstruct a regional absolute isotropic conductivity distribution in a region of interest (ROI) while avoiding the defective regions. First, the proposed method reconstructs the contrast of conductivity using the transversal J-substitution algorithm, which blocks the propagation of severe accumulated noise from the defective region to the ROI. Second, the proposed method reconstructs the regional projected current density using the relationships between the internal current density, which stems from a current injection on the surface, and the measured B z data. Combining the contrast conductivity distribution in the entire imaging

  8. Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting.

    Science.gov (United States)

    Luukkonen, Antti A M; Lehto, Tiina M; Hedberg, Pirjo S M; Vaskivuo, Tommy E

    2016-04-01

    Intensive care units, operating rooms, emergency departments, and neonatology units need rapid measurements of blood gases, electrolytes, and metabolites. These analyses can be performed in a central laboratory or at the clinic with traditional or compact cassette-type blood gas analyzers such as the epoc blood gas testing system for analyzing whole blood samples at the bedside. In this study, the performance and interchangeability of a hand-held epoc blood gas analyzer was evaluated. The analytical performance of the epoc analyzer was evaluated by determining within-and between-run precisions. The accuracy of the epoc analyzer was assessed by comparing patient results from the device with those obtained with the Siemens Rapidlab 1265 and Rapidpoint RP500 and Siemens Dimension Vista and Sysmex XE-2100 analyzers. The following parameters were measured: pH, pCO2, pO2, Hb (calc), Na+, K+, iCa2+, glucose, and lactate. The CV% of the epoc's between-day imprecision for the various parameters varied from 0.4 to 8.6. The within-run imprecision CV% varied from 0.6 to 5.2. The squared regression coefficient (R2) between the epoc and RL1265 varied from 0.94 to 0.99, with the exception of Na+ and Ca2+ (R2≥0.82). The correlation (R2) of Na+ and K+ between epoc and Dimension Vista was 0.73 and 0.89, respectively. The correlation (R2) of Hb between the epoc and the XE-2100 analyzer was 0.94. With most of the measured blood gas parameters, the epoc analyzer correlated well with reference techniques. The epoc analyzer is suitable for rapid measurement of the blood gases, the electrolytes, and the metabolites in the ICU.

  9. Absolute Astrometry in the next 50 Years - II

    Science.gov (United States)

    Høg, E.

    2018-01-01

    With the Gaia astrometric satellite in orbit since December 2013 it is time to look at the future of fundamental astrometry and a time frame of 50 years is needed in this matter. A space mission with Gaia-like astrometric performance is required, but not necessarily a Gaia-like satellite. A dozen science issues for a Gaia successor mission in twenty years, with launch about 2035, are presented and in this context also other possibilities for absolute astrometry with milliarcsecond (mas) or sub-mas accuracies are discussed in my report at http://arxiv.org/abs/1408.2190. In brief, the two missions (2013 and 2035) would provide an astrometric foundation for all branches of astronomy from the solar system and stellar systems, including exo-planet systems with long periods, to compact galaxies, quasars and Dark Matter substructures by data which cannot be surpassed in the next 50 years.

  10. Absolute configuration of cembrane diterpenoids from Bursera multijuga.

    Science.gov (United States)

    Hernández-Hernández, Juan D; García-Gutiérrez, Hugo A; Román-Marín, Luisa U; Torres-Blanco, Yunuen I; Cerda-García-Rojas, Carlos M; Joseph-Nathan, Pedro

    2014-09-01

    The stems of Bursera multijuga afforded (-)-(1S,3E,7R,8R,11E)-7,8-epoxycembra-3,11-dien-1-ol (1) and its acetate 2, together with cembrene A (3), nephthenol (4), and cembrenol (5). The structures of 1 and 2 were elucidated by 1D and 2D NMR, HRESIMS, and X-ray diffraction. The conformational preference of flexible 1 was studied by molecular modeling at the DFT B3LYP/DGDZVP level of theory. Good agreement between calculated and experimental vibrational circular dichroism curves established the absolute configuration of 1. This is the first time that cembrane derivatives have been isolated from the genus Bursera.

  11. Ensuring long-term stability of infrared camera absolute calibration.

    Science.gov (United States)

    Kattnig, Alain; Thetas, Sophie; Primot, Jérôme

    2015-07-13

    Absolute calibration of cryogenic 3-5 µm and 8-10 µm infrared cameras is notoriously instable and thus has to be repeated before actual measurements. Moreover, the signal to noise ratio of the imagery is lowered, decreasing its quality. These performances degradations strongly lessen the suitability of Infrared Imaging. These defaults are often blamed on detectors reaching a different "response state" after each return to cryogenic conditions, while accounting for the detrimental effects of imperfect stray light management. We show here that detectors are not to be blamed and that the culprit can also dwell in proximity electronics. We identify an unexpected source of instability in the initial voltage of the integrating capacity of detectors. Then we show that this parameter can be easily measured and taken into account. This way we demonstrate that a one month old calibration of a 3-5 µm camera has retained its validity.

  12. Absolutism versus doceañista liberalism. The Visual Counterattack

    Directory of Open Access Journals (Sweden)

    Carlos Reyero

    2017-09-01

    Full Text Available The aim of this article is to identify some dominants themes within absolutists discourses and to sketch out how they are translated to images, in order to persuade against and to denigrate liberalism. Descriptions of public ornaments in events honoring king Ferdinand VII in 1814 and 1823 are used as the main reference sources. Absolutism is recognized looking for associations between images and words, resemblances, metaphors, symbols and iconographic matches. Visual imagery to achieve absolutist goal emphasized the primacy of the king, the rhetoric of vassalage, a strong motherland, the uniqueness of religion, and the exclusion of the political enemy. In order to totally eliminate the constitutional risk, the tradition was presented as a paradise of peace and happiness.

  13. Absolute dimensions and evolutionary status of UW CMa

    International Nuclear Information System (INIS)

    Parthasarathy, M.

    1978-01-01

    Photoelectric B and V light curves of close binary system UW Canis Majoris (08.5 If + O-B) are analysed. Combining the photoelectric elements and the spectroscopic orbit absolute dimensions of the system are determined. The mass of the bright primary (08.5 If) component is found to be 19.3 solar masses and that of the faint secondary to be 23.2 solar masses. The primary has filled the Roche lobe and it is 1 to 2 mag over-luminous for its mass. The massive secondary component is most likely a main sequence star. Comparison with the theoretical evolutionary models of massive close binary systems undergoing case A of mass exchange indicate that UW CMa is close to the contact stage of evolution. (author)

  14. The absolute frequency of the 87Sr optical clock transition

    DEFF Research Database (Denmark)

    Campbell, Gretchen K.; Ludlow, Andrew D.; Blatt, Sebastian

    2008-01-01

    The absolute frequency of the 1S0–3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6 × 10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After...... a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice clock to 1.5 × 10-16, the clock frequency is measured against a hydrogen maser which is simultaneously calibrated to the US primary frequency standard, the NIST Cs fountain clock, NIST-F1. The comparison...... is made possible using a femtosecond laser based optical frequency comb to phase coherently connect the optical and microwave spectral regions and by a 3.5 km fibre transfer scheme to compare the remotely located clock signals....

  15. Cosmic backgrounds of relic gravitons and their absolute normalization

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    Provided the consistency relations are not violated, the recent Bicep2 observations pin down the absolute normalization, the spectral slope and the maximal frequency of the cosmic graviton background produced during inflation. The properly normalized spectra are hereby computed from the lowest frequencies (of the order of the present Hubble rate) up to the highest frequency range in the GHz region. Deviations from the conventional paradigm cannot be excluded and are examined by allowing for different physical possibilities including, in particular, a running of the tensor spectral index, an explicit breaking of the consistency relations and a spike in the high-frequency tail of the spectrum coming either from a post-inflationary phase dominated by a stiff fluid of from the contribution of waterfall fields in a hybrid inflationary context. The direct determinations of the tensor to scalar ratio at low frequencies, if confirmed by the forthcoming observations, will also affect and constrain the high-frequencies...

  16. Measured and modelled absolute gravity changes in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Jens Emil; Forsberg, René; Strykowski, Gabriel

    2014-01-01

    In glaciated areas, the Earth is responding to the ongoing changes of the ice sheets, a response knownas glacial isostatic adjustment (GIA). GIA can be investigated through observations of gravity change.For the ongoing assessment of the ice sheets mass balance, where satellite data are used...... in Greenland. Theresult is compared with the initial measurements of absolute gravity (AG) change at selected GreenlandNetwork (GNET) sites.We find that observations are highly influenced by the direct attraction from the ice and ocean. Thisis especially evident in the measurements conducted at the GNET...... station near the Helheim Glacier.The effect of the direct attraction diminishes at sites that are more than one degree from the source.Here, the dominant signal is the effect of the elastic signal from present day ice mass changes. We findagreement between the measured and modelled gravity changes at all...

  17. Measured and modelled absolute gravity changes in Greenland

    Science.gov (United States)

    Nielsen, J. Emil; Forsberg, Rene; Strykowski, Gabriel

    2014-01-01

    In glaciated areas, the Earth is responding to the ongoing changes of the ice sheets, a response known as glacial isostatic adjustment (GIA). GIA can be investigated through observations of gravity change. For the ongoing assessment of the ice sheets mass balance, where satellite data are used, the study of GIA is important since it acts as an error source. GIA consists of three signals as seen by a gravimeter on the surface of the Earth. These signals are investigated in this study. The ICE-5G ice history and recently developed ice models of present day changes are used to model the gravity change in Greenland. The result is compared with the initial measurements of absolute gravity (AG) change at selected Greenland Network (GNET) sites.

  18. Absolute distance measurement by two-point-diffraction interferometry

    International Nuclear Information System (INIS)

    Rhee, Hyug-Gyo; Kim, Seung-Woo

    2002-01-01

    We present a point-diffraction interferometer that has been specially devised to perform absolute distance measurements in three dimensions. It is composed of two main parts: One is a target that moves in three dimensions, and the other is a stationary two-dimensional array of photodetectors. The target is made of point-diffraction sources that emit two spherical wave fronts, whose interference is monitored by the photodetectors. Application of a phase-shifting technique allows the phase values of the photodetectors to be precisely measured, which are then fitted to a geometric model of multilateration so as to determine the xyz location of the target by minimization of least-squares errors. Experimental results show that the proposed diffraction interferometer is capable of measuring the xyz coordinates of the target with a volumetric uncertainty of less than 1.0 μm over a working volume of a 100-mm side

  19. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    Science.gov (United States)

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  20. Absolute Measurement of Tilts via Fourier Analysis of Interferograms

    Science.gov (United States)

    Toland, Ronald W.

    2004-01-01

    The Fourier method of interferogram analysis requires the introduction of a constant tilt into the interferogram to serve as a carrier signal for information on the figure of the surface under test. This tilt is usually removed in the first steps of analysis and ignored thereafter. However, in the problem of aligning optical components and systems, knowledge of part orientation is crucial to proper instrument performance. This paper outlines an algorithm which uses the normally ignored carrier signal in Fourier analysis to compute an absolute tilt (orientation) of the test surface. We also provide a brief outline of how this technique, incorporated in a rotating Twyman-Green interferometer, can be used in alignment and metrology of optical systems.

  1. Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Shafer, R. A.; Eplee, R. E.; Isaacman, R. B.; Fixsen, D. J.; Read, S. M.; Meyer, S. S.; Weiss, R.; Wright, E. L.

    1991-01-01

    The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.

  2. Absolute calibration of Doppler coherence imaging velocity images

    Science.gov (United States)

    Samuell, C. M.; Allen, S. L.; Meyer, W. H.; Howard, J.

    2017-08-01

    A new technique has been developed for absolutely calibrating a Doppler Coherence Imaging Spectroscopy interferometer for measuring plasma ion and neutral velocities. An optical model of the interferometer is used to generate zero-velocity reference images for the plasma spectral line of interest from a calibration source some spectral distance away. Validation of this technique using a tunable diode laser demonstrated an accuracy better than 0.2 km/s over an extrapolation range of 3.5 nm; a two order of magnitude improvement over linear approaches. While a well-characterized and very stable interferometer is required, this technique opens up the possibility of calibrated velocity measurements in difficult viewing geometries and for complex spectral line-shapes.

  3. The neurocognitive components of pitch processing: insights from absolute pitch.

    Science.gov (United States)

    Wilson, Sarah J; Lusher, Dean; Wan, Catherine Y; Dudgeon, Paul; Reutens, David C

    2009-03-01

    The natural variability of pitch naming ability in the population (known as absolute pitch or AP) provides an ideal method for investigating individual differences in pitch processing and auditory knowledge formation and representation. We have demonstrated the involvement of different cognitive processes in AP ability that reflects varying skill expertise in the presence of similar early age of onset of music tuition. These processes were related to different regions of brain activity, including those involved in pitch working memory (right prefrontal cortex) and the long-term representation of pitch (superior temporal gyrus). They reflected expertise through the use of context dependent pitch cues and the level of automaticity of pitch naming. They impart functional significance to structural asymmetry differences in the planum temporale of musicians and establish a neurobiological basis for an AP template. More generally, they indicate variability of knowledge representation in the presence of environmental fostering of early cognitive development that translates to differences in cognitive ability.

  4. Development of the absolute standardization apparatus for radon-222 activity.

    Science.gov (United States)

    Liang, Juncheng; Yang, Zhijie; Wang, Liyuan; Li, Zexi; Zhang, Ming; Liu, Haoran; Yuan, Daqing

    2018-04-01

    A defined solid angle counting apparatus for radon-222 activity absolute measurement is presented. Two home-made vacuum sealed radium-226 sources with radioactivity of 500kBq and 3MBq are used to minimize the impact from gas impurities. The defined solid angle is calculated using precisely measured geometrical parameters by several algorithms. The result from Monte Carlo simulation agrees with results obtained by other methods within the estimated uncertainty limit. Alpha particle's scattering behavior in the measurement chamber and collimator is simulated by the geant4 code and a total scattering alpha particle ratio of 0.23% as well as a relative uncertainty contribution to activity measurement of 0.02% to 0.09% are estimated. A typical total combined standard uncertainty of 0.28% is evaluated for the radon activity primary measurement. Copyright © 2017. Published by Elsevier Ltd.

  5. Absolute luminosity measurement at LHCb with beam-gas imaging

    CERN Document Server

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam-Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used *van der Meer scan* method (VDM). The technique has been used in 10 LHC fills during 2012 including and also provided a first luminosity measurement for proton-lead collisions. This talk presents the principles of the gas injection and the improvements reached with the increased pressure. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch. Those uncertainties are becoming the dominating factor because the uncertainty on the total beam current have been reduced.

  6. Gravitational Acceleration as a Cue for Absolute Size and Distance

    Science.gov (United States)

    Hecht, Heiko; Kaiser, Mary K.; Banks, Martin S.; Hart, Sandra G. (Technical Monitor)

    1994-01-01

    When an object's motion is influenced by gravity, such as the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In three experiments, we examined the ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory parallel to the gravitational vector. The simulated objects were three balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify which ball was presented and the distance at which it was presented. The results of Experiment 1 showed that size and distance judgments were significantly better than chance, but not as accurate as expected if the information contained in the dynamics of free fall were used fully utilized. The results of Experiment 2 showed that acceleration information is used, but that observers can also make use of velocity information. Finally, the results of Experiment 3 showed that observers can use projected size information, but that their size and distance judgments are much more accurate when motion information is present as well. These results show that observers can use the information in the dynamics of free fall to estimate absolute size and distance, but their estimates are not as accurate as they could be if the information were used effectively.

  7. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Reda, Ibrahim M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dooraghi, Michael R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Grobner, Julian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Thomann, Christian [Physikalisch-Meteorologisches Observatorium Davos (PMOD); Long, Chuck [National Oceanic and Atmospheric Administration; McComiskey, Allison [National Oceanic and Atmospheric Administration; Hall, Emiel [National Oceanic and Atmospheric Administration; Wacker, Stefan [Deutscher Wetterdienst

    2018-03-05

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

  8. Cylindrical Taylor states conserving total absolute magnetic helicity

    Science.gov (United States)

    Low, B. C.; Fang, F.

    2014-09-01

    The Taylor state of a three-dimensional (3D) magnetic field in an upright cylindrical domain V is derived from first principles as an extremum of the total magnetic energy subject to a conserved, total absolute helicity Habs. This new helicity [Low, Phys. Plasmas 18, 052901 (2011)] is distinct from the well known classical total helicity and relative total helicity in common use to describe wholly-contained and anchored fields, respectively. A given field B, tangential along the cylindrical side of V, may be represented as a unique linear superposition of two flux systems, an axially extended system along V and a strictly transverse system carrying information on field-circulation. This specialized Chandrasekhar-Kendall representation defines Habs and permits a neat formulation of the boundary-value problem (BVP) for the Taylor state as a constant-α force-free field, treating 3D wholly-contained and anchored fields on the same conceptual basis. In this formulation, the governing equation is a scalar integro-partial differential equation (PDE). A family of series solutions for an anchored field is presented as an illustration of this class of BVPs. Past treatments of the constant-α field in 3D cylindrical geometry are based on a scalar Helmholtz PDE as the governing equation, with issues of inconsistency in the published field solutions discussed over time in the journal literature. The constant-α force-free equation reduces to a scalar Helmholtz PDE only as special cases of the 3D integro-PDE derived here. In contrast, the constant-α force-free equation and the scalar Helmholtz PDE are absolutely equivalent in the spherical domain as discussed in Appendix. This theoretical study is motivated by the investigation of the Sun's corona but the results are also relevant to laboratory plasmas.

  9. Comparison of prognostic impact of absolute lymphocyte count, absolute monocyte count, absolute lymphocyte count/absolute monocyte count prognostic score and ratio in patients with diffuse large B cell lymphoma.

    Science.gov (United States)

    Markovic, Olivera; Popovic, Lazar; Marisavljevic, Dragomir; Jovanovic, Darjana; Filipovic, Branka; Stanisavljevic, Dejana; Matovina-Brko, Gorana; Hajder, Jelena; Matkovic, Tatjana; Živkovic, Radmila; Stanisavljevic, Natasa; Todorović, Milena; Petrovic, Dragana; Mihaljevic, Biljana

    2014-03-01

    The combination of absolute lymphocyte count (ALC) and absolute monocyte count (AMC) at diagnosis has prognostic relevance in patients with diffuse large B cell lymphoma (DLBCL). The present study was designed to investigate the prognostic significance of ALC and AMC and to determine whether ALC/AMC ratio or ALC/AMC prognostic score is better predictor of outcome in DLBCL. We retrospectively analyzed the prognostic significance of ALC and AMC, ALC/AMC ratio and ALC/AMC prognostic score at diagnosis in 222 DLBCL patients treated with R-CHOP. ROC analysis showed that optimal cut-off values of AMC and ALC/AMC ratio with the best sensitivity and specificity were 0.59×10(9)/L and 2.8, respectively. Cut-off of ALC was determined according to the literature data (1×10(9)/L). Low ALC, high AMC, low ALC/AMC ratio and high ALC/AMC prognostic score were in significant association with lower rate of therapy response and survival. In contrast, these parameters were not in significant correlation with relapse rate. The patients with low ALC, "high" AMC, low ALC/AMC ratio and high ALC/AMC prognostic score at diagnosis had significantly shorter EFS and OS. In multivariate analysis all tested parameters (ALC, AMC, ALC/AMC prognostic score and ALC/AMC ratio) are independent risk factors along with "bulky" disease and IPI. All tested parameters (ALC, AMC, ALC/AMC score and ALC/AMC ratio) may be useful prognostic factors in DLBCL patients. ALC/AMC score has a slight advantage as it allows the classification of patients into three prognostic groups. Further studies are needed to determine which of these parameters has the highest predictive value. Copyright © 2014 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  10. New Reference Models for Pacific Absolute Plate Motion

    Science.gov (United States)

    Wessel, P.

    2012-12-01

    Absolute plate motion (APM) models are commonly derived by assuming that age-progressive seamount chains represent the surface expressions of mantle plumes; the chain geometries thus record the relative motion between plumes and plates. Traditionally, plumes have been assigned zero motion (i.e., the fixed hotspot hypothesis), and with this assumption the trails directly reflect plate motion. However, since the early 1970s arguments from sedimentary facies and marine magnetics have been marshaled against the fixity of hotspots, perhaps culminating with more recent and direct inferences of anomalous paleolatitudes for several seamounts in both the Emperor and Louisville chains. These data can broadly be explained by drifting plumes, but paleomagnetic data remain scarce and may allow for some true polar wander; furthermore, several age progressions are incomplete or inconsistent and the present locations of some hotspots are uncertain. Finally, APM models with moving hotspots derive largely from mantle flow modeling whose predictions do not match observations directly. Here, I present new absolute plate motion models for the Pacific plate back to 150 Ma. The first model assumes fixed hotspots and is meant to serve as a reference model representing the classic fixed hotspot hypothesis. It is an updated version of the Wessel and Kroenke [2008] model but now including all available chains, recently published age data and processed using improved modeling techniques. The second model uses the same data but also attempts to honor available data on hotspot mobility. It is intended to be a "work in progress" model that will be updated as additional paleolatitude or age data become available. These models can serve as test beds for tectonic hypothesis and be used to identify seamount chain segments where additional paleomagnetic or age observations would have the most impact.

  11. Regional and site-specific absolute humidity data for use in tritium dose calculations

    International Nuclear Information System (INIS)

    Etnier, E.L.

    1980-01-01

    Due to the potential variability in average absolute humidity over the continental U.S., and the dependence of atmospheric 3 H specific activity on absolute humidity, availability of regional absolute humidity data is of value in estimating the radiological significance of 3 H releases. Most climatological data are in the form of relative humidity, which must be converted to absolute humidity for dose calculations. Absolute humidity was calculated for 218 points across the U.S., using the 1977 annual summary of U.S. Climatological Data, and is given in a table. Mean regional values are shown on a map. (author)

  12. Absolute Thermal SST Measurements over the Deepwater Horizon Oil Spill

    Science.gov (United States)

    Good, W. S.; Warden, R.; Kaptchen, P. F.; Finch, T.; Emery, W. J.

    2010-12-01

    Climate monitoring and natural disaster rapid assessment require baseline measurements that can be tracked over time to distinguish anthropogenic versus natural changes to the Earth system. Disasters like the Deepwater Horizon Oil Spill require constant monitoring to assess the potential environmental and economic impacts. Absolute calibration and validation of Earth-observing sensors is needed to allow for comparison of temporally separated data sets and provide accurate information to policy makers. The Ball Experimental Sea Surface Temperature (BESST) radiometer was designed and built by Ball Aerospace to provide a well calibrated measure of sea surface temperature (SST) from an unmanned aerial system (UAS). Currently, emissive skin SST observed by satellite infrared radiometers is validated by shipborne instruments that are expensive to deploy and can only take a few data samples along the ship track to overlap within a single satellite pixel. Implementation on a UAS will allow BESST to map the full footprint of a satellite pixel and perform averaging to remove any local variability due to the difference in footprint size of the instruments. It also enables the capability to study this sub-pixel variability to determine if smaller scale effects need to be accounted for in models to improve forecasting of ocean events. In addition to satellite sensor validation, BESST can distinguish meter scale variations in SST which could be used to remotely monitor and assess thermal pollution in rivers and coastal areas as well as study diurnal and seasonal changes to bodies of water that impact the ocean ecosystem. BESST was recently deployed on a conventional Twin Otter airplane for measurements over the Gulf of Mexico to access the thermal properties of the ocean surface being affected by the oil spill. Results of these measurements will be presented along with ancillary sensor data used to eliminate false signals including UV and Synthetic Aperture Radar (SAR

  13. An Absolute Valve for the ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Jones, Ch.; Chuilon, B.; Michael, W.

    2006-01-01

    In the ITER reference design a fast shutter was included to limit tritium migration into the beamline vacuum enclosures. The need was recently identified to extend the functionality of the fast shutter to that of an absolute valve in order to facilitate injector maintenance procedures and to satisfy safety requirements in case of an in-vessel loss of coolant event. Three concepts have been examined satisfying the ITER requirements for speed of actuation, sealing performance over the required lifetime, and pressure differential in fault scenarios, namely: a rectangular closure section; a circular cross section; and a rotary JET-type valve. The rectangular section represents the most efficient usage of the available space envelope and leads to a minimum-mass system, although it requires greater total force for a given load per unit length of seal. However, a metallic seal of the '' hard/hard '' type, where the seal relies on the elastic properties of the material and does not utilise any type of spring device, can provide the required seal performance with typical loading of 200 kg/cm. The conceptual design of the proposed absolute valve will be presented. The aperture dimensions are 1.45 m high by 0.6 m wide, with minimum achievable leak rate of 1 · 10 -9 mbarl/s and maximum pressure differential of 3 bar across the valve. Sealing force is provided using two seal plates, linked by a 3 mm thick ' omega ' diaphragm, by pressurisation of the interspace to 8 bar; this allows for a relative movement of the plates of 2 mm. Movement of the device perpendicular to the beam direction is carried out using a novel magnetic drive in order to transmit the motive force across the vacuum boundary, similar to that demonstrated on a test-rig in an earlier study. The conceptual design includes provision of all the services such as pneumatics and water cooling to cope with the heat loads from neutral beams in quasi steady-state operation and from the ITER plasma. A future programme

  14. Gravitational acceleration as a cue for absolute size and distance?

    Science.gov (United States)

    Hecht, H.; Kaiser, M. K.; Banks, M. S.

    1996-01-01

    When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.

  15. Absolute Dimensions of Contact Binary Stars in Baade Window

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    1999-12-01

    Full Text Available The light curves of the representative 6 contact binary stars observed by OGLE Project of searching for dark matter in our Galaxy have been analyzed by the method of the Wilson and Devinney Differential Correction to find photometric solutions. The orbital inclinations of these binaries are in the range of 52 deg - 69 deg which is lower than that of the solar neighborhood binaries. The Roche lobe filling factor of these binaries are distributed in large range of 0.12 - 0.90. Since absence of spectroscopic observations for these binaries we have found masses of the 6 binary systems based on the intersection between Kepler locus and locus derived from Vandenberg isochrones in the mass - luminosity plane. Then absolute dimensions and distances have been found by combining the masses and the photometric solutions. The distances of the 6 binary systems are distributed in the range of 1 kpc - 6 kpc. This distance range is the limiting range where the contact binaries which have period shorter than a day are visible. Most contact binaries discovered in the Baade window do not belong to the Galactic bulge.

  16. An absolute calibration system for millimeter-accuracy APOLLO measurements

    Science.gov (United States)

    Adelberger, E. G.; Battat, J. B. R.; Birkmeier, K. J.; Colmenares, N. R.; Davis, R.; Hoyle, C. D.; Huang, L. R.; McMillan, R. J.; Murphy, T. W., Jr.; Schlerman, E.; Skrobol, C.; Stubbs, C. W.; Zach, A.

    2017-12-01

    Lunar laser ranging provides a number of leading experimental tests of gravitation—important in our quest to unify general relativity and the standard model of physics. The apache point observatory lunar laser-ranging operation (APOLLO) has for years achieved median range precision at the  ∼2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in situ. The system consists of a high-repetition-rate (80 MHz) laser emitting short (work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.

  17. Athermal fiber laser for the SWARM absolute scalar magnetometer

    Science.gov (United States)

    Fourcault, W.; Léger, J.-M.; Costes, V.; Fratter, I.; Mondin, L.

    2017-11-01

    The Absolute Scalar Magnetometer (ASM) developed by CEA-LETI/CNES is an optically pumped 4He magnetic field sensor based on the Zeeman effect and an electronic magnetic resonance whose effects are amplified by a laser pumping process [1-2]. Consequently, the role of the laser is to pump the 4He atoms at the D0 transition as well as to allow the magnetic resonance signal detection. The ASM will be the scalar magnetic reference instrument of the three ESA Swarm satellites to be launched in 2012 in order to carry out the best ever survey of the Earth magnetic field and its temporal evolution. The sensitivity and accuracy of this magnetometer based on 4He optical pumping depend directly on the characteristics of its light source, which is the key sub-system of the sensor. We describe in this paper the selected fiber laser architecture and its wavelength stabilization scheme. Its main performance in terms of spectral emission, optical power at 1083 nm and intensity noise characteristics in the frequency bands used for the operation of the magnetometer, are then presented. Environmental testing results (thermal vacuum cycling, vibrations, shocks and ageing) are also reported at the end of this paper.

  18. The Romantic subject as an absolutely autonomous individual

    Directory of Open Access Journals (Sweden)

    Miljana Cunta

    2004-12-01

    Full Text Available This essay deals with the Romantic subject as a philosophical and literary category. Recog­ nizing the diversity and complexity of literary production in the Romantic period, this study does not attempt to treat all the many aspects of this subject, but it instead focuses upan a few: the role of nature, the status of imagination, and the subject's relation to the transcendental reality. In its rela­ tion to these issues, the Romantic subject appears as an absolutely autonomous individual, one who finds no satisfaction in claims to transcendental certainty made by any source outside the self, but relies on his immanent powers to achieve the self-awareness that is the only sure access to truth. Special attention is given to the Romantic mystical experience, whereby the subject eames into relation with the transcendental reality. Here what are termed mystical feelings are contrasted with religious feelings proper so as to stress the peculiarities of the Romantic religious experience. In providing a theoretical framewok for the religious experience, we have recourse to Rudolf Otto's definition of the "numinous," which denotes the feeling response of the subject to the divine aspect of reality. In comparison with the true religious experience, the Romantic type is seen as pseudo­- religious, thus confirming the proposed definition of the Romantic subject as a truly autonomous individual. The essay's second part contains an interpretation of selected poems by Samuel Taylor Coleridge with a view of extrapolating from them some aspects of the Romantic subject.

  19. A high-precision mechanical absolute-rotation sensor.

    Science.gov (United States)

    Venkateswara, Krishna; Hagedorn, Charles A; Turner, Matthew D; Arp, Trevor; Gundlach, Jens H

    2014-01-01

    We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad/√Hz above 30 mHz and 0.2 nrad/√Hz above 100 mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 μm above the pivot, giving an excellent horizontal displacement rejection of better than 3 × 10(-5) rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad/√Hz sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced Laser Interferometer Gravitational-wave Observatory.

  20. Targeting LDL Cholesterol: Beyond Absolute Goals Toward Personalized Risk.

    Science.gov (United States)

    Leibowitz, Morton; Cohen-Stavi, Chandra; Basu, Sanjay; Balicer, Ran D

    2017-06-01

    The aim of this study was to review and assess the evidence for low-density lipoprotein cholesterol (LDL-C) treatment goals as presented in current guidelines for primary and secondary prevention of cardiovascular disease. Different sets of guidelines and clinical studies for secondary prevention have centered on lower absolute LDL-C targets [achieve greater reductions in cardiovascular risk. Population-based risk models serve as the basis for statin initiation in primary prevention. Reviews of current population risk models for primary prevention show moderate ability to discriminate [with c-statistics ranging from 0.67 to 0.77 (95% CIs from 0.62 to 0.83) for men and women] with poor calibration and overestimation of risk. Individual clinical trial data are not compelling to support specific LDL-C targets and percent reductions in secondary prevention. Increasing utilization of electronic health records and data analytics will enable the development of individualized treatment goals in both primary and secondary prevention.

  1. Do individuals with Williams syndrome possess absolute pitch?

    Science.gov (United States)

    Martínez-Castilla, Pastora; Sotillo, María; Campos, Ruth

    2013-01-01

    Although absolute pitch (AP) is a rare skill in typical development, individuals with Williams syndrome (WS) are often referred to as possessing this musical ability. However, there is paucity of research on the topic. In this article, 2 studies were conducted to evaluate AP in WS. In Study 1, seven musically trained individuals with WS, 14 musically trained typically developing controls matched for chronological age, and 2 experienced musicians with AP completed a pitch-identification task. Although the task was a classical assessment of AP, it required participants to have musical knowledge, and the availability and accessibility of musically trained individuals with WS is very low. In Study 2, a paradigm suitable for evaluating AP in individuals without musical training was used, which made it possible to evaluate a larger group of participants with WS. A pitch memory test for isolated tones was presented to 27 individuals with WS, 54 typically developing peers matched for chronological age, and the 2 musicians with AP. Both individuals with WS and their controls obtained low results in the two studies. They showed an arbitrary pattern of response, and their performance was far from that of musicians with AP. Therefore, participants with WS did not appear to possess AP. Unlike what is usually claimed, results suggest that AP is not a remarkable ability in WS and that, as in the typically developing population, this musical ability is also rare in individuals with WS.

  2. Quest for absolute zero in the presence of external noise.

    Science.gov (United States)

    Torrontegui, E; Kosloff, R

    2013-09-01

    A reciprocating quantum refrigerator is analyzed with the intention to study the limitations imposed by external noise. In particular we focus on the behavior of the refrigerator when it approaches the absolute zero. The cooling cycle is based on the Otto cycle with a working medium constituted by an ensemble of noninteracting harmonic oscillators. The compression and expansion segments are generated by changing an external parameter in the Hamiltonian. In this case the force constant of the harmonic oscillators mω^{2} is modified from an initial to a final value. As a result, the kinetic and potential energy of the system do not commute causing frictional losses. By proper choice of scheduling function ω(t) frictionless solutions can be obtained in the noiseless case. We examine the performance of a refrigerator subject to noise. By expanding from the adiabatic limit we find that the external noise, Gaussian phase, and amplitude noises reduce the amount of heat that can be extracted but nevertheless the zero temperature can be approached.

  3. Design and Fabrication of Micromachined Absolute Micro Pressure Sensor

    Directory of Open Access Journals (Sweden)

    P. A. Alvi

    2008-09-01

    Full Text Available Absolute micro pressure sensors have been designed and fabricated in batches, which will be capable to give output responses in form of voltage signal as a function of pressure. The piezoresistive effect has been chosen for this device because it provides an observable resistance changes that is a linear function of pressure and is observable at low stress levels. A membrane is used as a stress-magnifying device. The pressure-induced stresses in the membrane are sensed by properly oriented piezoresistors interconnected to form a bridge. For the purpose of pressure sensing, boron doped polysilicon piezoresistors have been fabricated in half Wheatstone bridge configuration. A 100 µm sized square membrane, over which polysilicon resistors are deposited, has been realized having thickness of 0.8 µm with the help of a sacrificial layer of LPCVD polysilicon thin film. Highly selective anisotropic etching of silicon has been performed in 45 % wt KOH at 75 oC for conical cavity formation under the membrane. The developed fabrication process is competent to provide nearly 1089 chips of 1 mm x 1 mm size on a two-inch diameter silicon (100 wafer.

  4. A nonmusical paradigm for identifying absolute pitch possessors

    Science.gov (United States)

    Ross, David A.; Olson, Ingrid R.; Marks, Lawrence E.; Gore, John C.

    2004-09-01

    The ability to identify and reproduce sounds of specific frequencies is remarkable and uncommon. The etiology and defining characteristics of this skill, absolute pitch (AP), have been very controversial. One theory suggests that AP requires a specific type of early musical training and that the ability to encode and remember tones depends on these learned musical associations. An alternate theory argues that AP may be strongly dependent on hereditary factors and relatively independent of musical experience. To date, it has been difficult to test these hypotheses because all previous paradigms for identifying AP have required subjects to employ knowledge of musical nomenclature. As such, these tests are insensitive to the possibility of discovering AP in either nonmusicians or musicians of non-Western training. Based on previous literature in pitch memory, a paradigm is presented that is intended to distinguish between AP possessors and nonpossessors independent of the subjects' musical experience. The efficacy of this method is then tested with 20 classically defined AP possessors and 22 nonpossessors. Data from these groups strongly support the validity of the paradigm. The use of a nonmusical paradigm to identify AP may facilitate research into many aspects of this phenomenon.

  5. Near-infrared absolute magnitudes of Type Ia Supernovae

    Science.gov (United States)

    Avelino, Arturo; Friedman, Andrew S.; Mandel, Kaisey; Kirshner, Robert; Challis, Peter

    2017-01-01

    Type Ia Supernovae light curves (SN Ia) in the near infrared (NIR) exhibit low dispersion in their peak luminosities and are less vulnerable to extinction by interstellar dust in their host galaxies. The increasing number of high quality NIR SNe Ia light curves, including the recent CfAIR2 sample obtained with PAIRITEL, provides updated evidence for their utility as standard candles for cosmology. Using NIR YJHKs light curves of ~150 nearby SNe Ia from the CfAIR2 and CSP samples, and from the literature, we determine the mean value and dispersion of the absolute magnitude in the range between -10 to 50 rest-frame days after the maximum luminosity in B band. We present the mean light-curve templates and Hubble diagram for YJHKs bands. This work contributes to a firm local anchor for supernova cosmology studies in the NIR which will help to reduce the systematic uncertainties due to host galaxy dust present in optical-only studies. This research is supported by NSF grants AST-156854, AST-1211196, Fundacion Mexico en Harvard, and CONACyT.

  6. Analysis of absolute flatness testing in sub-stitching interferometer

    Science.gov (United States)

    Jia, Xin; Xu, Fuchao; Xie, Weimin; Xing, Tingwen

    2016-09-01

    Sub-aperture stitching is an effective way to extend the lateral and vertical dynamic range of a conventional interferometer. The test accuracy can be achieved by removing the error of reference surface by the absolute testing method. When the testing accuracy (repeatability and reproducibility) is close to 1nm, in addition to the reference surface, other factors will also affect the measuring accuracy such as environment, zoom magnification, stitching precision, tooling and fixture, the characteristics of optical materials and so on. In the thousand level cleanroom, we establish a good environment system. Long time stability, temperature controlled at 22°+/-0.02°.The humidity and noise are controlled in a certain range. We establish a stitching system in the clean room. The vibration testing system is used to test the vibration. The air pressure testing system is also used. In the motion system, we control the tilt error no more than 4 second to reduce the error. The angle error can be tested by the autocollimator and double grating reading head.

  7. Accurate absolute measurement of trapped Cs atoms in a MOT

    International Nuclear Information System (INIS)

    Talavera O, M.; Lopez R, M.; Carlos L, E. de; Jimenez S, S.

    2007-01-01

    A Cs-133 Magneto-Optical Trap (MOT) has been developed at the Time and Frequency Division of the Centro Nacional de Metrologia, CENAM, in Mexico. This MOT is part of a primary frequency standard based on ultra-cold Cs atoms, called CsF-1 clock, under development at CENAM. In this Cs MOT, we use the standard configuration (σ + - σ - ) 4-horizontal 2-vertical laser beams 1.9 cm in diameter, with 5 mW each. We use a 852 nm, 5 mW, DBR laser as a master laser which is stabilized by saturation spectroscopy. Emission linewidth of the master laser is l MHz. In order to amplify the light of the master laser, a 50 mW, 852 nm AlGaAs laser is used as slave laser. This slave laser is stabilized by light injection technique. A 12 MHz red shift of the light is performed by two double passes through two Acusto-Optic Modulators (AOMs). The optical part of the CENAMs MOT is very robust against mechanical vibration, acoustic noise and temperature changes in our laboratory, because none of our diode lasers use an extended cavity to reduce the linewidth. In this paper, we report results of our MOT characterization as a function of several operation parameters such as the intensity of laser beams, the laser beam diameter, the red shift of light, and the gradient of the magnetic field. We also report accurate absolute measurement of the number of Cs atoms trapped in our Cs MOT. We found up to 6 x 10 7 Cs atoms trapped in our MOT measured with an uncertainty no greater than 6.4%. (Author)

  8. Absolute pitch: effects of timbre on note-naming ability.

    Directory of Open Access Journals (Sweden)

    Patrícia Vanzella

    2010-11-01

    Full Text Available Absolute pitch (AP is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names, it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP possessors to identify. A musician's first instrument may also affect performance and extend the sensitive period for acquiring accurate AP.A large sample of AP possessors was recruited on-line. Participants were required to identity test tones presented in four different timbres: piano, pure tone, natural (sung voice, and synthesized voice. Note-naming accuracy was better for non-vocal (piano and pure tones than for vocal (natural and synthesized voices test tones. This difference could not be attributed solely to vibrato (pitch variation, which was more pronounced in the natural voice than in the synthesized voice. Although starting music lessons by age 7 was associated with enhanced note-naming accuracy, equivalent abilities were evident among listeners who started music lessons on piano at a later age.Because the human voice is inextricably linked to language and meaning, it may be processed automatically by voice-specific mechanisms that interfere with note naming among AP possessors. Lessons on piano or other fixed-pitch instruments appear to enhance AP abilities and to extend the sensitive period for exposure to music in order to develop accurate AP.

  9. Absolute pitch: effects of timbre on note-naming ability.

    Science.gov (United States)

    Vanzella, Patrícia; Schellenberg, E Glenn

    2010-11-11

    Absolute pitch (AP) is the ability to identify or produce isolated musical tones. It is evident primarily among individuals who started music lessons in early childhood. Because AP requires memory for specific pitches as well as learned associations with verbal labels (i.e., note names), it represents a unique opportunity to study interactions in memory between linguistic and nonlinguistic information. One untested hypothesis is that the pitch of voices may be difficult for AP possessors to identify. A musician's first instrument may also affect performance and extend the sensitive period for acquiring accurate AP. A large sample of AP possessors was recruited on-line. Participants were required to identity test tones presented in four different timbres: piano, pure tone, natural (sung) voice, and synthesized voice. Note-naming accuracy was better for non-vocal (piano and pure tones) than for vocal (natural and synthesized voices) test tones. This difference could not be attributed solely to vibrato (pitch variation), which was more pronounced in the natural voice than in the synthesized voice. Although starting music lessons by age 7 was associated with enhanced note-naming accuracy, equivalent abilities were evident among listeners who started music lessons on piano at a later age. Because the human voice is inextricably linked to language and meaning, it may be processed automatically by voice-specific mechanisms that interfere with note naming among AP possessors. Lessons on piano or other fixed-pitch instruments appear to enhance AP abilities and to extend the sensitive period for exposure to music in order to develop accurate AP.

  10. Development of a graphite probe calorimeter for absolute clinical dosimetry

    International Nuclear Information System (INIS)

    Renaud, James; Seuntjens, Jan; Sarfehnia, Arman; Marchington, David

    2013-01-01

    The aim of this work is to present the numerical design optimization, construction, and experimental proof of concept of a graphite probe calorimeter (GPC) conceived for dose measurement in the clinical environment (U.S. provisional patent 61/652,540). A finite element method (FEM) based numerical heat transfer study was conducted using a commercial software package to explore the feasibility of the GPC and to optimize the shape, dimensions, and materials used in its design. A functioning prototype was constructed inhouse and used to perform dose to water measurements under a 6 MV photon beam at 400 and 1000 MU/min, in a thermally insulated water phantom. Heat loss correction factors were determined using FEM analysis while the radiation field perturbation and the graphite to water absorbed dose conversion factors were calculated using Monte Carlo simulations. The difference in the average measured dose to water for the 400 and 1000 MU/min runs using the TG-51 protocol and the GPC was 0.2% and 1.2%, respectively. Heat loss correction factors ranged from 1.001 to 1.002, while the product of the perturbation and dose conversion factors was calculated to be 1.130. The combined relative uncertainty was estimated to be 1.4%, with the largest contributors being the specific heat capacity of the graphite (type B, 0.8%) and the reproducibility, defined as the standard deviation of the mean measured dose (type A, 0.6%). By establishing the feasibility of using the GPC as a practical clinical absolute photon dosimeter, this work lays the foundation for further device enhancements, including the development of an isothermal mode of operation and an overall miniaturization, making it potentially suitable for use in small and composite radiation fields. It is anticipated that, through the incorporation of isothermal stabilization provided by temperature controllers, a subpercent overall uncertainty will be achieved.

  11. Absolute homogeneity test of Kelantan catchment precipitation series

    Science.gov (United States)

    Ros, Faizah Che; Tosaka, Hiroyuki; Sasaki, Kenji; Sidek, Lariyah Mohd; Basri, Hidayah

    2015-05-01

    Along the Kelantan River in north east of Malaysia Peninsular, there are several areas often damaged by flood during north-east monsoon season every year. It is vital to predict the expected behavior of precipitation and river runoff for reducing flood damages of the area under rapid urbanization and future planning. Nevertheless, the accuracy and reliability of any hydrological and climate studies vary based on the quality of the data used. The factors causing variations on these data are the method of gauging and data collection, stations environment, station relocation and the reliability of the measurement tool affect the homogenous precipitation records. Hence in this study, homogeneity of long precipitation data series is checked via the absolute homogeneity test consisting of four methods namely Pettitt test, standard normal homogeneity test (SNHT), Buishand range test and Von Neumann ratio test. For homogeneity test, the annual rainfall amount from the daily precipitation records at stations located in Kelantan operated by Department of Irrigation and Drainage Malaysia were considered in this study. The missing values were completed using the correlation and regression and inverse distance method. The data network consists of 103 precipitation gauging stations where 31 points are inactive, 6 gauging stations had missing precipitation values more than five years in a row and 16 stations have records less than twenty years. So total of 50 stations gauging stations were evaluated in this analysis. With the application of the mentioned methods and further graphical analysis, inhomogeneity was detected at 4 stations and 46 stations are found to be homogeneous.

  12. Intraplate Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K. G.; Camelbeeck, T.

    2007-12-01

    We have conducted repeated absolute gravity (AG) measurements across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken since 2000 and repeated twice a year. Our analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36.7 nm s-2/year equivalent to 18.4 mm/yr is due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nms-2 to 43±29 nms-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. In Ostend, the AG time series agrees with tide gauge data, global mean sea level and altimeter measurements but disagrees with the CGPS. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes in an intraplate context.

  13. Vertical Land Movements Constrained by Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M.; Williams, S. D.; Hinzen, K.; Camelbeeck, T.

    2009-05-01

    Repeated absolute gravity (AG) measurements have been performed across the tectonically active intraplate regions in Northwest Europe: the Ardenne and the Roer Graben. At most of the stations measurements were undertaken in 2000 and repeated twice a year. Analysis of these measurements, performed in Belgium and Germany, show that at all stations except Jülich, there is no detectable gravity variation higher than 10 nm s-2 at the 95% confidence level. This is equivalent to vertical movements of 5 mm/yr. Although not yet significant, the observed rates do not contradict the subsidence predicted by glacial isostatic adjustment models and provide an upper limit on the possible uplift of the Ardennes. In Jülich, a gravity rate of change of 36 nm -2/year, equivalent to 18 mm/yr, is at least in parts due to anthropogenic subsidence. The amplitudes of the seasonal variations range from 18±0.8 nm s-2 to 43±29 nm s-2, depending on the location. These variations should have a negligible effect on the long-term trend, but at the Membach reference station, were a longer time series is available, differences in the rates observed since 1996 and 1999 indicate that long-term environmental effects may influence the inferred trend. The observed seasonal effects also demonstrate the repeatability of AG measurements. This study indicates that, even in difficult conditions, AG measurements repeated once a year can resolve vertical land movements at a few mm level after 5 years. This also confirms the need to measure for decades, using accurate and stable geodetic techniques like AG, in order to constrain slow deformation processes.

  14. Fundamental principles of absolute radiometry and the philosophy of this NBS program (1968 to 1971)

    Science.gov (United States)

    Geist, J.

    1972-01-01

    A description is given work performed on a program to develop an electrically calibrated detector (also called absolute radiometer, absolute detector, and electrically calibrated radiometer) that could be used to realize, maintain, and transfer a scale of total irradiance. The program includes a comprehensive investigation of the theoretical basis of absolute detector radiometry, as well as the design and construction of a number of detectors. A theoretical analysis of the sources of error is also included.

  15. Binomial Distribution Sample Confidence Intervals Estimation 7. Absolute Risk Reduction and ARR-like Expressions

    Directory of Open Access Journals (Sweden)

    Andrei ACHIMAŞ CADARIU

    2004-08-01

    Full Text Available Assessments of a controlled clinical trial suppose to interpret some key parameters as the controlled event rate, experimental event date, relative risk, absolute risk reduction, relative risk reduction, number needed to treat when the effect of the treatment are dichotomous variables. Defined as the difference in the event rate between treatment and control groups, the absolute risk reduction is the parameter that allowed computing the number needed to treat. The absolute risk reduction is compute when the experimental treatment reduces the risk for an undesirable outcome/event. In medical literature when the absolute risk reduction is report with its confidence intervals, the method used is the asymptotic one, even if it is well know that may be inadequate. The aim of this paper is to introduce and assess nine methods of computing confidence intervals for absolute risk reduction and absolute risk reduction – like function.Computer implementations of the methods use the PHP language. Methods comparison uses the experimental errors, the standard deviations, and the deviation relative to the imposed significance level for specified sample sizes. Six methods of computing confidence intervals for absolute risk reduction and absolute risk reduction-like functions were assessed using random binomial variables and random sample sizes.The experiments shows that the ADAC, and ADAC1 methods obtains the best overall performance of computing confidence intervals for absolute risk reduction.

  16. Development of a Shear Deformable Element Using the Absolute Nodal Coordinate Formulation

    National Research Council Canada - National Science Library

    Omar, Mohamed

    2000-01-01

    .... The effect of the shear deformation is accounted for without the need for introducing Timoshenko's shear coefficient By using the absolute coordinates, the nonlinear strain-displacement relationships...

  17. Regional neonatal brain absolute thermometry by 1H MRS.

    Science.gov (United States)

    Bainbridge, Alan; Kendall, Giles S; De Vita, Enrico; Hagmann, Cornelia; Kapetanakis, Andrew; Cady, Ernest B; Robertson, Nicola J

    2013-04-01

    Therapeutic hypothermia is standard care for infants with moderate to severe encephalopathy. (1) H MRS thermometry (MRSt) measures regional brain absolute temperature using the temperature-dependent water chemical shift. This study evaluates the clinical feasibility of MRSt in human neonates, and correlates white matter (WM) and thalamus (Thal) MRSt with conventional rectal temperature (Trectal ) measurement. Fifty-six infants born at term underwent perinatal MRSt for suspected hypoxic-ischaemic brain injury and 33 infants born preterm had MRSt at a term-equivalent age; 56 of the 89 had Trectal measured after MRSt of either a Thal or posterior WM voxel, or both. MRSt used point-resolved spectroscopy (no water suppression; TR = 1370 ms; TE = 288 ms; 1.5 × 1.5 × 1.5 cm(3) Thal and 1.1 × 1.3 × 1.4 cm(3) WM voxels). Time domain data were phase and frequency corrected before summation and motion-corrupted data were excluded from further analysis using simple criteria [preprocessing + quality assurance (QA)]. Two published water temperature-dependence calibrations [both using cerebral creatine (Cr), choline (Cho) and N-acetylaspartate (Naa) as independent reference peaks] were compared. The temperature measurements derived from Cr, Cho and Naa were combined to give a single amplitude-weighted combination temperature (TAWC ). WM and Thal TAWC correlated linearly with Trectal (Thal slope, 0.82 ± 0.04, R(2) = 0.85, p < 0.05; WM slope, 0.95 ± 0.04, R(2) = 0.78, p < 0.05). Preprocessing + QA improved the correlation between WM TAWC and Trectal (R(2) increased from 0.27 to 0.78, p < 0.001). Both calibration datasets showed specific inconsistencies between the temperatures calculated using Cr, Cho and Naa reference peaks when applied to this neonatal dataset. Neonatal MRSt is clinically feasible. Preprocessing + QA improved MRSt reliability in WM. The consideration of MRSt calibration internal biases is necessary before combining MRSt temperatures from multiple

  18. Global change and the measurement of absolute sea-level

    Science.gov (United States)

    Diamante, John M.; Pyle, Thomas E.; Carter, William E.; Scherer, Wolfgang

    -300) required for global climate research programmes (WYRTKI and PUGH, 1984) need to be upgraded to “sea-level observatory” status, in terms of sensors and geodetic control, to build a two tier sea-level network that will provide the data needed to solve many problems of both relative and absolute sea-level change. Such a network will provide basic information supporting research on a wide range of questions related to “global change”.

  19. Absolute cardiovascular risk in a Fiji medical zone.

    Science.gov (United States)

    Gyaneshwar, Rajat; Naidu, Swaran; Raban, Magdalena Z; Naidu, Sheetal; Linhart, Christine; Morrell, Stephen; Tukana, Isimeli; Taylor, Richard

    2016-02-09

    The population of Fiji has experienced emergence of non-communicable disease (NCD) and a plateau in life expectancy over the past 20 years. A mini-STEPS survey (n = 2765) was conducted in Viseisei in Western Fiji to assess NCD risk factors (RFs) in i-Taukei (Melanesians) and those of Indian descent aged 25-64 years (response 73 %). Hypertension (HT) was defined as systolic blood pressure (BP) ≥140 mmHg or diastolic BP ≥90 mmHg or on medication for HT; type 2 diabetes mellitus (T2DM) as fasting plasma glucose ≥7.0 mmol/L or on medication for T2DM; and obesity as a body mass index (kilograms/height(metres)(2)) ≥30. Data were age-adjusted to 2007 Fiji Census. Associations between RFs and ethnicity/education were investigated. Comparisons with Fiji STEPS surveys were undertaken, and the absolute risk of a cardiovascular disease (CVD) event/death in 10 years was estimated from multiple RF charts. NCD/RFs increased with age except excessive alcohol intake and daily smoking (women) which declined. Daily smoking was higher in men 33 % (95 % confidence interval: 31-36) than women 14 % (12-116); women were more obese 40 % (37-43) than men 23 % (20-26); HT was similar in men 37 % (34-40) and women 34 % (31-36), as was T2DM in men 15 % (13-17) and women 17 % (15-19). i-Taukei men had an odds ratio (OR) of 0.41 (0.28-0.58) for T2DM compared to Indians (1.00); and i-Taukei (both sexes) had a higher OR for obesity and low fruit/vegetable intake, daily smoking, excessive alcohol intake and HT in females. Increasing education correlated with lesser smoking, but with higher obesity and lower fruit/vegetable intake. Compared to the 2011 Fiji STEPS survey, no significant differences were evident in obesity, HT or T2DM prevalences. The proportion (40-64 years) classified at high or very high risk (≥20 %) of a CVD event/death (over 10 years) based on multiple RFs was 8.3 % for men (8.1 % i-Taukei, 8.5 % Indian), and 6.7 % for women (7.9 % i-Taukei, 6.0 % Indian). The results

  20. Absolute and convective instabilities in combined Couette-Poiseuille flow past a neo-Hookean solid

    Science.gov (United States)

    Patne, Ramkarn; Shankar, V.

    2017-12-01

    Temporal and spatio-temporal stability analyses are carried out to characterize the occurrence of convective and absolute instabilities in combined Couette-Poiseuille flow of a Newtonian fluid past a deformable, neo-Hookean solid layer in the creeping-flow limit. Plane Couette flow of a Newtonian fluid past a neo-Hookean solid becomes temporally unstable in the inertia-less limit when the parameter Γ = V η/(GR) exceeds a critical value. Here, V is the velocity of the top plate, η is the fluid viscosity, G is the shear modulus of the solid layer, and R is the fluid layer thickness. The Kupfer-Bers method is employed to demarcate regions of absolute and convective instabilities in the Γ-H parameter space, where H is the ratio of solid to fluid thickness in the system. For certain ranges of the thickness ratio H, we find that the flow could be absolutely unstable, and the critical Γ required for absolute instability is very close to that for temporal instability, thus making the flow absolutely unstable at the onset of temporal instability. In some cases, there is a gap in the parameter Γ between the temporal and absolute instability boundaries. The present study thus shows that absolute instabilities are possible, even at very low Reynolds numbers in flow past deformable solid surfaces. The presence of absolute instabilities could potentially be exploited in the enhancement of mixing at low Reynolds numbers in flow through channels with deformable solid walls.

  1. Strong laws for generalized absolute Lorenz curves when data are stationary and ergodic sequences

    NARCIS (Netherlands)

    R. Helmers (Roelof); R. Zitikis

    2004-01-01

    textabstractWe consider generalized absolute Lorenz curves that include, as special cases, classical and generalized L - statistics as well as absolute or, in other words, generalized Lorenz curves. The curves are based on strictly stationary and ergodic sequences of random variables. Most of the

  2. Absolute stability of nonlinear systems with time delays and applications to neural networks

    Directory of Open Access Journals (Sweden)

    Xinzhi Liu

    2001-01-01

    Full Text Available In this paper, absolute stability of nonlinear systems with time delays is investigated. Sufficient conditions on absolute stability are derived by using the comparison principle and differential inequalities. These conditions are simple and easy to check. In addition, exponential stability conditions for some special cases of nonlinear delay systems are discussed. Applications of those results to cellular neural networks are presented.

  3. Articulated Multimedia Physics, Lesson 14, Gases, The Gas Laws, and Absolute Temperature.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    As the fourteenth lesson of the Articulated Multimedia Physics Course, instructional materials are presented in this study guide with relation to gases, gas laws, and absolute temperature. The topics are concerned with the kinetic theory of gases, thermometric scales, Charles' law, ideal gases, Boyle's law, absolute zero, and gas pressures. The…

  4. The absolute magnetometers on board Swarm, lessons learned from more than two years in space

    DEFF Research Database (Denmark)

    Hulot, Gauthier; Leger, Jean-Michel; Vigneron, Pierre

    ESA's Swarm satellites carry 4He absolute magnetometers (ASM), designed by CEA-Léti and developed in partnership with CNES. These instruments are the first-ever space-borne magnetometers to use a common sensor to simultaneously deliver 1Hz independent absolute scalar and vector readings of the ma...

  5. Absolute migration of Pacific basin mid-ocean ridges since 85 Ma ...

    African Journals Online (AJOL)

    Mid-ocean ridges are major physiographic features that dominate the world seafloor. Their absolute motion and tectonics are recorded in magnetic lineations they created. The absolute migration of mid-ocean ridges in the Pacific basin since 85 Ma and their tectonic implications was investigated in this work and the results ...

  6. Absolute humidity and the seasonal onset of influenza in the continental United States.

    Directory of Open Access Journals (Sweden)

    Jeffrey Shaman

    2010-02-01

    Full Text Available Much of the observed wintertime increase of mortality in temperate regions is attributed to seasonal influenza. A recent reanalysis of laboratory experiments indicates that absolute humidity strongly modulates the airborne survival and transmission of the influenza virus. Here, we extend these findings to the human population level, showing that the onset of increased wintertime influenza-related mortality in the United States is associated with anomalously low absolute humidity levels during the prior weeks. We then use an epidemiological model, in which observed absolute humidity conditions temper influenza transmission rates, to successfully simulate the seasonal cycle of observed influenza-related mortality. The model results indicate that direct modulation of influenza transmissibility by absolute humidity alone is sufficient to produce this observed seasonality. These findings provide epidemiological support for the hypothesis that absolute humidity drives seasonal variations of influenza transmission in temperate regions.

  7. Study on absolute humidity influence of NRL-1 measuring apparatus for radon

    International Nuclear Information System (INIS)

    Shan Jian; Xiao Detao; Zhao Guizhi; Zhou Qingzhi; Liu Yan; Qiu Shoukang; Meng Yecheng; Xiong Xinming; Liu Xiaosong; Ma Wenrong

    2014-01-01

    The absolute humidity and temperature's effects on the NRL-1 measuring apparatus for radon were studied in this paper. By controlling the radon activity concentration of the radon laboratory in University of South China and improving the temperature and humidity adjust strategy, different correction factor values under different absolute humidities were obtained. Moreover, a correction curve between 1.90 and 14.91 g/m 3 was also attained. The results show that in the case of absolute humidity, when it is less than 2.4 g/m 3 , collection efficiency of the NRL-1 measuring apparatus for radon tends to be constant, and the correction factor of the absolute humidity closes to 1. However, the correction factor increases nonlinearly along with the absolute humidity. (authors)

  8. First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak

    Science.gov (United States)

    Rodriguez-Ramos, M.; Garcia-Munoz, M.; Jimenez-Ramos, M. C.; Garcia Lopez, J.; Galdon-Quiroga, J.; Sanchis-Sanchez, L.; Ayllon-Guerola, J.; Faitsch, M.; Gonzalez-Martin, J.; Hermann, A.; de Marne, P.; Rivero-Rodriguez, J. F.; Sieglin, B.; Snicker, A.; the ASDEX Upgrade Team

    2017-10-01

    A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.

  9. New design and facilities for the International Database for Absolute Gravity Measurements (AGrav): A support for the Establishment of a new Global Absolute Gravity Reference System

    Science.gov (United States)

    Wziontek, Hartmut; Falk, Reinhard; Bonvalot, Sylvain; Rülke, Axel

    2017-04-01

    After about 10 years of successful joint operation by BGI and BKG, the International Database for Absolute Gravity Measurements "AGrav" (see references hereafter) was under a major revision. The outdated web interface was replaced by a responsive, high level web application framework based on Python and built on top of Pyramid. Functionality was added, like interactive time series plots or a report generator and the interactive map-based station overview was updated completely, comprising now clustering and the classification of stations. Furthermore, the database backend was migrated to PostgreSQL for better support of the application framework and long-term availability. As comparisons of absolute gravimeters (AG) become essential to realize a precise and uniform gravity standard, the database was extended to document the results on international and regional level, including those performed at monitoring stations equipped with SGs. By this it will be possible to link different AGs and to trace their equivalence back to the key comparisons under the auspices of International Committee for Weights and Measures (CIPM) as the best metrological realization of the absolute gravity standard. In this way the new AGrav database accommodates the demands of the new Global Absolute Gravity Reference System as recommended by the IAG Resolution No. 2 adopted in Prague 2015. The new database will be presented with focus on the new user interface and new functionality, calling all institutions involved in absolute gravimetry to participate and contribute with their information to built up a most complete picture of high precision absolute gravimetry and improve its visibility. A Digital Object Identifier (DOI) will be provided by BGI to contributors to give a better traceability and facilitate the referencing of their gravity surveys. Links and references: BGI mirror site : http://bgi.obs-mip.fr/data-products/Gravity-Databases/Absolute-Gravity-data/ BKG mirror site: http

  10. Characterization of Methane Excess and Absolute Adsorption in Various Clay Nanopores from Molecular Simulation.

    Science.gov (United States)

    Tian, Yuanyuan; Yan, Changhui; Jin, Zhehui

    2017-09-20

    In this work, we use grand canonical Monte Carlo (GCMC) simulation to study methane adsorption in various clay nanopores and analyze different approaches to characterize the absolute adsorption. As an important constituent of shale, clay minerals can have significant amount of nanopores, which greatly contribute to the gas-in-place in shale. In previous works, absolute adsorption is often calculated from the excess adsorption and bulk liquid phase density of absorbate. We find that methane adsorbed phase density keeps increasing with pressure up to 80 MPa. Even with updated adsorbed phase density from GCMC, there is a significant error in absolute adsorption calculation. Thus, we propose to use the excess adsorption and adsorbed phase volume to calculate absolute adsorption and reduce the discrepancy to less than 3% at high pressure conditions. We also find that the supercritical Dubinin-Radushkevich (SDR) fitting method which is commonly used in experiments to convert the excess adsorption to absolute adsorption may not have a solid physical foundation for methane adsorption. The methane excess and absolute adsorptions per specific surface area are similar for different clay minerals in line with previous experimental data. In mesopores, the excess and absolute adsorptions per specific surface area become insensitive to pore size. Our work should provide important fundamental understandings and insights into accurate estimation of gas-in-place in shale reservoirs.

  11. Absolute Kα line spectroscopy for cone-guided fast-ignition targets

    Directory of Open Access Journals (Sweden)

    Nishimura H.

    2013-11-01

    Full Text Available Absolute Kα line spectroscopy is proposed to study laser-plasma interactions taking place in cone-guided fast ignition targets. A transmission-type spectrometer was developed, and its absolute sensitivity was measured with laser-generated x-rays and radioisotopes, showing good agreement with theoretical predictions. The absolute yield of Au Kα line was mesured in the fast ignition experimental campaign perfomed at ILE, Osaka University. Assuming a single Maxwellian electron spectrum and one-way travel of hot electrons through the cone, energy transfer efficiency of incident LFEX laser to hot electrons was derived.

  12. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    CERN Document Server

    Yoshikawa, M; Kawamori, E; Watanabe, Y; Watabe, C; Yamaguchi, N; Tamano, T

    2001-01-01

    A grazing incidence flat-field soft X-ray (20-350 A) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  13. Absolute calibration of space-resolving soft X-ray spectrograph for plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, M. E-mail: yosikawa@prc.tsukuba.ac.jp; Okamoto, Y.; Kawamori, E.; Watanabe, Y.; Watabe, C.; Yamaguchi, N.; Tamano, T

    2001-07-21

    A grazing incidence flat-field soft X-ray (20-350 A) spectrograph was constructed and applied for impurity diagnostics in the GAMMA 10 fusion plasma. The spectrograph consisted of a limited height entrance slit, an aberration-corrected concave grating, a microchannel-plate intensified detector and an instant camera/a high speed solid state camera. An absolute calibration experiment for the SX spectrograph was performed at the Photon Factory in the High Energy Accelerator Research Organization with monitoring the incident synchrotron beam intensity by using an absolutely calibrated XUV silicon photodiode. From the results of absolute calibration of the spectrograph, the radiation loss from the plasma was obtained.

  14. Gathering and Dispersing: The Absolute Spirit in Hegel’s Philosophy

    Directory of Open Access Journals (Sweden)

    George Vassilacopoulos

    2007-12-01

    Full Text Available This paper explores the meaning and being of the absolute spirit in Hegelrsquo;s thought by reflecting through the idea that spirit is the activity and being of gathering through dispersal. In Hegelrsquo;s thought gathering and dispersing are the primary movements through which spirit engages in the processes of its absolute self-cognition, the processes, that is, that underpin the eternal becoming of communal being. Gathering and dispersing thus define the pulsating movement of the absolute spirit in all its facets

  15. Swarm's absolute magnetometer experimental vector mode, an innovative capability for space magnetometry

    DEFF Research Database (Denmark)

    Hulot, Gauthier; Vigneron, Pierre; Leger, Jean-Michel

    2015-01-01

    ESA's Swarm satellites carry a new generation of 4He absolute magnetometers (ASM), designed by CEA-Leti and developed in partnership with CNES. These instruments are the rst-ever space-born magnetometers to use a common sensor to simultaneously deliver 1Hz independent absolute scalar and vector...... be monitored from space with such absolute vector magnetometers....... readings of the magnetic eld. Since launch, these ASMs provided very high accuracy scalar eld data, as nominally required for the mission, together with experimental vector eld data. Here, we compare geomagnetic eld models built from such ASM-only data with models built from the mission's nominal 1Hz data...

  16. Comparison of elicitation potential of chloroatranol and atranol - 2 allergens in oak moss absolute

    DEFF Research Database (Denmark)

    Johansen, J.D.; Bernard, G.; Gimenez-Arnau, E.

    2006-01-01

    Chloroatranol and atranol are degradation products of chloroatranorin and atranorin, respectively, and have recently been identified as important contact allergens in the natural fragrance extract, oak moss absolute. Oak moss absolute is widely used in perfumery and is the cause of many cases...... of fragrance allergic contact dermatitis. Chloroatranol elicits reactions at very low levels of exposure. In oak moss absolute, chloroatranol and atranol are present together and both may contribute to the allergenicity and eliciting capacity of the natural extract. In this study, 10 eczema patients with known...... sensitization to chloroatranol and oak moss absolute were tested simultaneously to a serial dilution of chloroatranol and atranol in ethanol, in equimolar concentrations (0.0034-1072 microM). Dose-response curves were estimated and analysed by logistic regression. The estimated difference in elicitation potency...

  17. The use of absolute refractory period in the estimation of early postmortem interval.

    Science.gov (United States)

    McDowall, K L; Lenihan, D V; Busuttil, A; Glasby, M A

    1998-02-16

    The estimation of the time since death (postmortem interval) is one of the most difficult problems in forensic pathology. Most methods currently employed use temperature-based algorithms intended to model the cooling of the body after death and thus estimate the postmortem interval. These methods are subject to considerable inaccuracy but their reliability can be improved if a range of other observed criteria such as lividity and rigor are also taken into consideration. The aim of the present study was to investigate the feasibility of using the absolute refractory period as an adjunct to the estimation of postmortem interval. The relationship between the 'postmortem interval' and the 'duration of absolute refractory period' was investigated using the rat sciatic nerve. A strong correlation between the duration of the absolute refractory period and the postmortem interval was observed. When both absolute refractory period and temperature were used in conjunction, the strength of this correlation was increased.

  18. Absolute Monotonicity of Functions Related To Estimates of First Eigenvalue of Laplace Operator on Riemannian Manifolds

    Directory of Open Access Journals (Sweden)

    Feng Qi

    2014-10-01

    Full Text Available The authors find the absolute monotonicity and complete monotonicity of some functions involving trigonometric functions and related to estimates the lower bounds of the first eigenvalue of Laplace operator on Riemannian manifolds.

  19. Absolute phase unwrapping for dual-camera system without embedding statistical features

    Science.gov (United States)

    Jiang, Chufan; Zhang, Song

    2017-09-01

    This paper proposes an absolute phase unwrapping method for three-dimensional measurement that uses two cameras and one projector. On the left camera image, each pixel has one wrapped phase value, which corresponds to multiple projector candidates with different absolute phase values. We use the geometric relationship of the system to map projector candidates into the right camera candidates. By applying a series of candidate rejection criteria, a unique correspondence pair between two camera images can be determined. Then, the absolute phase is obtained by tracing the correspondence point back to the projector space. Experimental results demonstrate that the proposed absolute phase unwrapping algorithm can successfully work on both complex geometry and multiple isolated objects measurement.

  20. Sea Surface Height, Absolute, Aviso, 0.25 degrees, Global, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aviso Absolute Sea Surface Height is the Sea Surface Height Deviation plus the long term mean dynamic height. This is Science Quality data.

  1. Combining Near-Subject Absolute and Relative Measures of Longitudinal Hydration in Hemodialysis

    OpenAIRE

    Chan, Cian; McIntyre, Christopher; Smith, David; Spanel, Patrik; Davies, Simon J.

    2009-01-01

    Background and objectives: The feasibility and additional value of combining bioimpedance analysis (BIA) with near-subject absolute measurement of total body water using deuterium dilution (TBWD) in determining longitudinal fluid status was investigated.

  2. Radii of Redox Components from Absolute Redox Potentials Compared with Covalent and Aqueous Ionic Radii

    Czech Academy of Sciences Publication Activity Database

    Heyrovská, Raji

    2010-01-01

    Roč. 22, č. 9 (2010), s. 903-907 ISSN 1040-0397 Institutional support: RVO:68081707 Keywords : Electrochemistry * Absolute redox potentials * Radii of redox components Subject RIV: BO - Biophysics Impact factor: 2.721, year: 2010

  3. The fading American dream: Trends in absolute income mobility since 1940.

    Science.gov (United States)

    Chetty, Raj; Grusky, David; Hell, Maximilian; Hendren, Nathaniel; Manduca, Robert; Narang, Jimmy

    2017-04-28

    We estimated rates of "absolute income mobility"-the fraction of children who earn more than their parents-by combining data from U.S. Census and Current Population Survey cross sections with panel data from de-identified tax records. We found that rates of absolute mobility have fallen from approximately 90% for children born in 1940 to 50% for children born in the 1980s. Increasing Gross Domestic Product (GDP) growth rates alone cannot restore absolute mobility to the rates experienced by children born in the 1940s. However, distributing current GDP growth more equally across income groups as in the 1940 birth cohort would reverse more than 70% of the decline in mobility. These results imply that reviving the "American dream" of high rates of absolute mobility would require economic growth that is shared more broadly across the income distribution. Copyright © 2017, American Association for the Advancement of Science.

  4. A description of the space of Banach space-valued absolutely p ...

    African Journals Online (AJOL)

    Abstract. Click on the link to view the abstract. Keywords: Absolutely p-summable sequence, Banach space, Banach lattice, 1-concave operator, sequence space. Quaestiones Mathematicae 31(2008), 101–105 ...

  5. Determination of the Absolute Stereochemistry of Secondary Alcohols: An Advanced Organic Chemistry Experiment for Undergraduate Students.

    Science.gov (United States)

    Bandaranayake, Wickramasinghe M.

    1980-01-01

    Describes experiments which can be completed in five four-hour laboratory sessions, including two synthesis (alpha-phenylbutyric and alpha-phenylbutyric acid anhydride) and determining the absolute stereochemistry of secondary alcohols using the synthetic products. (JN)

  6. Absolute exponential stability of recurrent neural networks with Lipschitz-continuous activation functions and time delays.

    Science.gov (United States)

    Cao, Jinde; Wang, Jun

    2004-04-01

    This paper investigates the absolute exponential stability of a general class of delayed neural networks, which require the activation functions to be partially Lipschitz continuous and monotone nondecreasing only, but not necessarily differentiable or bounded. Three new sufficient conditions are derived to ascertain whether or not the equilibrium points of the delayed neural networks with additively diagonally stable interconnection matrices are absolutely exponentially stable by using delay Halanay-type inequality and Lyapunov function. The stability criteria are also suitable for delayed optimization neural networks and delayed cellular neural networks whose activation functions are often nondifferentiable or unbounded. The results herein answer a question: if a neural network without any delay is absolutely exponentially stable, then under what additional conditions, the neural networks with delay is also absolutely exponentially stable.

  7. Absolute Wavelength Control of Lasers for Active Sensing in Space, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop compact absolute wavelength references to weak molecular transitions, which is a challenge characteristic to space-based active sensing. The...

  8. On determining absolute entropy without quantum theory or the third law of thermodynamics

    Science.gov (United States)

    Steane, Andrew M.

    2016-04-01

    We employ classical thermodynamics to gain information about absolute entropy, without recourse to statistical methods, quantum mechanics or the third law of thermodynamics. The Gibbs-Duhem equation yields various simple methods to determine the absolute entropy of a fluid. We also study the entropy of an ideal gas and the ionization of a plasma in thermal equilibrium. A single measurement of the degree of ionization can be used to determine an unknown constant in the entropy equation, and thus determine the absolute entropy of a gas. It follows from all these examples that the value of entropy at absolute zero temperature does not need to be assigned by postulate, but can be deduced empirically.

  9. Absolute measurement of the thermal conductivity of insulating materials at high temperature

    International Nuclear Information System (INIS)

    Liermann, J.

    1975-01-01

    A device was developed at the CEA for the absolute measurement of the thermal conductivity of insulators. It can operate in controlled atmospheres (air, CO 2 , Ar, He) and between 100 and 1050 deg C [fr

  10. Determination of the absolute configuration of (+) - surinamensin's via diastereomeric O-methylmandelic esters

    International Nuclear Information System (INIS)

    Santos, L. da S.; Barata, L.E.S.

    1990-01-01

    The absolute configurarion of (+) surinamensin, a 8.0.4' neolignan, has been determined based on its O-methymandalates esters. Nuclear magnetic resonance and infrared and mass spectroscopy analysis are presented. (C.G.C.) [pt

  11. Geomagnetic Absolute Mean Values at Hourly Intervals from 220 Observatories Worldwide

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This file is comprised of absolute mean hourly values of the geomagnetic components D, H and Z or X, Y and Z. These values, on magnetic tape, are available from...

  12. Effect of Absolute From Hibiscus syriacus L. Flower on Wound Healing in Keratinocytes.

    Science.gov (United States)

    Yoon, Seok Won; Lee, Kang Pa; Kim, Do-Yoon; Hwang, Dae Il; Won, Kyung-Jong; Lee, Dae Won; Lee, Hwan Myung

    2017-01-01

    Proliferation and migration of keratinocytes are essential for the repair of cutaneous wounds. Hibiscus syriacus L. has been used in Asian medicine; however, research on keratinocytes is inadequate. To establish the dermatological properties of absolute from Hibiscus syriacus L. flower (HSF) and to provide fundamental research for alternative medicine. We identified the composition of HSF absolute using gas chromatography-mass spectrometry analysis. We also examined the effect of HSF absolute in HaCaT cells using the XTT assay, Boyden chamber assay, sprout-out growth assay, and western blotting. We conducted an in-vivo wound healing assay in rat tail-skin. Ten major active compounds were identified from HSF absolute. As determined by the XTT assay, Boyden chamber assay, and sprout-out growth assay results, HSF absolute exhibited similar effects as that of epidermal growth factor on the proliferation and migration patterns of keratinocytes (HaCaT cells), which were significantly increased after HSF absolute treatment. The expression levels of the phosphorylated signaling proteins relevant to proliferation, including extracellular signal-regulated kinase 1/2 (Erk 1/2) and Akt, were also determined by western blot analysis. These results of our in-vitro and ex-vivo studies indicate that HSF absolute induced cell growth and migration of HaCaT cells by phosphorylating both Erk 1/2 and Akt. Moreover, we confirmed the wound-healing effect of HSF on injury of the rat tail-skin. Therefore, our results suggest that HSF absolute is promising for use in cosmetics and alternative medicine. Hisbiscus syriacus L. flower absolute increases HaCaT cell migration and proliferation. Hisbiscus syriacus L. flower absolute regulates phosphorylation of ERK 1/2 and Akt in HaCaT cell.Treatment with Hisbiscus syriacus L. flower induced sprout outgrowth.The wound in the tail-skin of rat was reduced by Hisbiscus syriacus L. flower absolute Abbreviations used: HSF: Hibiscus syriacus L. flower

  13. Relationship between Income and Subjective Economic Well-Being: Absolute or Relative?

    Directory of Open Access Journals (Sweden)

    V A Khashchenko

    2012-09-01

    Full Text Available The article considers the role of the absolute and relative income in determining the subjective economic well-being. It is shown that the relationship of the income to SEB is curvilinear with the increase of marginal utility for a higher income. At low income levels its effect on SEB is determined not by its absolute, but by its relative value based on the comparisons with the subjective standards of well-being.

  14. Effect of Absolute From Hibiscus syriacus L. Flower on Wound Healing in Keratinocytes

    OpenAIRE

    Yoon, Seok Won; Lee, Kang Pa; Kim, Do-Yoon; Hwang, Dae Il; Won, Kyung-Jong; Lee, Dae Won; Lee, Hwan Myung

    2017-01-01

    Background: Proliferation and migration of keratinocytes are essential for the repair of cutaneous wounds. Hibiscus syriacus L. has been used in Asian medicine; however, research on keratinocytes is inadequate. Objective: To establish the dermatological properties of absolute from Hibiscus syriacus L. flower (HSF) and to provide fundamental research for alternative medicine. Materials and Methods: We identified the composition of HSF absolute using gas chromatography-mass spectrometry analysi...

  15. Memory for musical tempo: Additional evidence that auditory memory is absolute

    OpenAIRE

    Levitin, Daniel J.; Cook, Perry R.

    1996-01-01

    We report evidence that long term memory retains absolute (accurate) features of perceptual events. Specifically, we show that memory for music seems to preserve the absolute tempo of the musical performance. In Experiment 1, 46 subjects sang popular songs from memory, and their tempos were compared to recorded versions of the songs. Seventy-two of the subjects came within 8% of the actual tempo on two consecutive trials (using different songs), demonstrating accuracy near the perceptual thre...

  16. Synthesis and absolute configurations of the cytotoxic polyacetylenes isolated from the callus of Panax ginseng.

    Science.gov (United States)

    Fujimoto, Y; Satoh, M; Takeuchi, N; Kirisawa, M

    1990-06-01

    Panaxacol (1) and dihydropanaxacol (2), cytotoxic polyacetylenes isolated from the callus of Panax ginseng, were synthesized starting from D-(-)-diethyl tartrate. The absolute configuration of 1 was determined to be 9R, 10R and the absolute configuration at C-3 of 2 was tentatively assigned as 3S by the application of the R(+)-alpha-methoxy-alpha-(trifluoro methyl)phenylacetyl (MTPA) method.

  17. The policy relevance of absolute and relative poverty headcounts: What's in a number?

    OpenAIRE

    Notten, Geranda; de Neubourg, Chris

    2007-01-01

    Financial poverty indicators still play an important role in policymaking and evaluation. Countries such as the USA and the EU member states use one or several ‘official’ poverty indicators on which success of poverty reduction policy is regularly monitored. Whereas the US poverty indicator is based on an absolute concept of poverty, the EU Laeken indicator is based on a relative concept. But the consequences of such a decision are considerable. As absolute and relative poverty indicators ref...

  18. Absolute quantification in multi-pinhole micro-SPECT for different isotopes

    OpenAIRE

    Vandeghinste, Bert; Vanhove, Christian; De Beenhouwer, Jan; Van Holen, Roel; Vandenberghe, Stefaan; Staelens, Steven

    2011-01-01

    In preclinical Single Photon Emission Tomography (SPECT), absolute quantification is interesting, expressed in percentage of injected radioactive dose per gram of tissue. This allows for accurate evaluation of disease progression and precise follow-up studies without the need for sacrificing animals. Accurate modeling of image degrading effects is currently under development for isotopes different from 99mTc. The aim of this work is to develop absolute micro-SPECT quantification for three dif...

  19. Absolute continuity of autophage measures on finite-dimensional vector spaces

    International Nuclear Information System (INIS)

    Raja, C.R.E.

    2002-06-01

    We consider a class of measures called autophage which was introduced and studied by Szekely for measures on the real line. We show that the autophage measures on finite-dimensional vector spaces over real or Q p are infinitely divisible without idempotent factors and are absolutely continuous with bounded continuous density. We also show that certain semistable measures on such vector spaces are absolutely continuous. (author)

  20. Absolute 3PO triple differential cross sections for electron-helium Wannier threshold ionisation

    International Nuclear Information System (INIS)

    Carruthers, D.R.J.; Crothers, D.S.F.

    1992-01-01

    The uniform semiclassical approximation of Crothers is employed to find a final-state 3 P O wave function for threshold electron impact ionisation of helium. The Kohn variational principle is applied perturbatively to evaluate the scattering amplitude and hence the absolute 3 P O contribution to the triple differential cross sections. These plus the previous absolute singlet results of Crothers are compared favourably with the relative experimental results of Selles et al. (orig.)

  1. Should heart age calculators be used alongside absolute cardiovascular disease risk assessment?

    OpenAIRE

    Bonner, Carissa; Bell, Katy; Jansen, Jesse; Glasziou, Paul; Irwig, Les; Doust, Jenny; McCaffery, Kirsten

    2018-01-01

    Background National estimates of ‘heart age’ by government health organisations in the US, UK and China show most people have an older heart age than current age. While most heart age calculators are promoted as a communication tool for lifestyle change, they may also be used to justify medication when clinical guidelines advocate their use alongside absolute risk assessment. However, only those at high absolute risk of a heart attack or stroke are likely to benefit from medication, and it is...

  2. A novel capacitive absolute positioning sensor based on time grating with nanometer resolution

    Science.gov (United States)

    Pu, Hongji; Liu, Hongzhong; Liu, Xiaokang; Peng, Kai; Yu, Zhicheng

    2018-05-01

    The present work proposes a novel capacitive absolute positioning sensor based on time grating. The sensor includes a fine incremental-displacement measurement component combined with a coarse absolute-position measurement component to obtain high-resolution absolute positioning measurements. A single row type sensor was proposed to achieve fine displacement measurement, which combines the two electrode rows of a previously proposed double-row type capacitive displacement sensor based on time grating into a single row. To achieve absolute positioning measurement, the coarse measurement component is designed as a single-row type displacement sensor employing a single spatial period over the entire measurement range. In addition, this component employs a rectangular induction electrode and four groups of orthogonal discrete excitation electrodes with half-sinusoidal envelope shapes, which were formed by alternately extending the rectangular electrodes of the fine measurement component. The fine and coarse measurement components are tightly integrated to form a compact absolute positioning sensor. A prototype sensor was manufactured using printed circuit board technology for testing and optimization of the design in conjunction with simulations. Experimental results show that the prototype sensor achieves a ±300 nm measurement accuracy with a 1 nm resolution over a displacement range of 200 mm when employing error compensation. The proposed sensor is an excellent alternative to presently available long-range absolute nanometrology sensors owing to its low cost, simple structure, and ease of manufacturing.

  3. Telling in-tune from out-of-tune: widespread evidence for implicit absolute intonation.

    Science.gov (United States)

    Van Hedger, Stephen C; Heald, Shannon L M; Huang, Alex; Rutstein, Brooke; Nusbaum, Howard C

    2017-04-01

    Absolute pitch (AP) is the rare ability to name or produce an isolated musical note without the aid of a reference note. One skill thought to be unique to AP possessors is the ability to provide absolute intonation judgments (e.g., classifying an isolated note as "in-tune" or "out-of-tune"). Recent work has suggested that absolute intonation perception among AP possessors is not crystallized in a critical period of development, but is dynamically maintained by the listening environment, in which the vast majority of Western music is tuned to a specific cultural standard. Given that all listeners of Western music are constantly exposed to this specific cultural tuning standard, our experiments address whether absolute intonation perception extends beyond AP possessors. We demonstrate that non-AP listeners are able to accurately judge the intonation of completely isolated notes. Both musicians and nonmusicians showed evidence for absolute intonation recognition when listening to familiar timbres (piano and violin). When testing unfamiliar timbres (triangle and inverted sine waves), only musicians showed weak evidence of absolute intonation recognition (Experiment 2). Overall, these results highlight a previously unknown similarity between AP and non-AP possessors' long-term musical note representations, including evidence of sensitivity to frequency.

  4. Error analysis in newborn screening: can quotients support the absolute values?

    Science.gov (United States)

    Arneth, Borros; Hintz, Martin

    2017-03-01

    Newborn screening is performed using modern tandem mass spectrometry, which can simultaneously detect a variety of analytes, including several amino acids and fatty acids. Tandem mass spectrometry measures the diagnostic parameters as absolute concentrations and produces fragments which are used as markers of specific substances. Several prominent quotients can also be derived, which are quotients of two absolute measured concentrations. In this study, we determined the precision of both the absolute concentrations and the derived quotients. First, the measurement error of the absolute concentrations and the measurement error of the ratios were practically determined. Then, the Gaussian theory of error calculation was used. Finally, these errors were compared with one another. The practical analytical accuracies of the quotients were significantly higher (e.g., coefficient of variation (CV) = 5.1% for the phenylalanine to tyrosine (Phe/Tyr) quotient and CV = 5.6% for the Fisher quotient) than the accuracies of the absolute measured concentrations (mean CVs = 12%). According to our results, the ratios are analytically correct and, from an analytical point of view, can support the absolute values in finding the correct diagnosis.

  5. A property of logarithmically absolutely monotonic functions and the logarithmically complete monotonicity of a power-exponential function

    OpenAIRE

    Qi, Feng; Guo, Bai-Ni

    2009-01-01

    In the article, a notion "logarithmically absolutely monotonic function" is introduced, an inclusion that a logarithmically absolutely monotonic function is also absolutely monotonic is revealed, the logarithmically complete monotonicity and the logarithmically absolute monotonicity of the function $\\bigl(1+\\frac{\\alpha}x\\bigr) ^{x+\\beta}$ are proved, where $\\alpha$ and $\\beta$ are given real parameters, a new proof for the inclusion that a logarithmically completely monotonic function is als...

  6. Should heart age calculators be used alongside absolute cardiovascular disease risk assessment?

    Science.gov (United States)

    Bonner, Carissa; Bell, Katy; Jansen, Jesse; Glasziou, Paul; Irwig, Les; Doust, Jenny; McCaffery, Kirsten

    2018-02-07

    National estimates of 'heart age' by government health organisations in the US, UK and China show most people have an older heart age than current age. While most heart age calculators are promoted as a communication tool for lifestyle change, they may also be used to justify medication when clinical guidelines advocate their use alongside absolute risk assessment. However, only those at high absolute risk of a heart attack or stroke are likely to benefit from medication, and it is not always clear how heart age relates to absolute risk. This article aims to: 1) explain how heart age calculation methods relate to absolute risk guidelines; 2) summarise research investigating whether heart age improves risk communication; and 3) discuss implications for the use of medication and shared decision making in clinical practice. There is a large and growing number of heart age models and online calculators, but the clinical meaning of an older heart age result is highly variable. An older heart age result may indicate low, moderate or high absolute risk of a heart attack or stroke in the next 5-10 years, and the same individual may receive a younger or older heart age result depending on which calculator is used. Heart age may help doctors convey the need to change lifestyle, but it cannot help patients make an informed choice about medication to reduce CVD risk. Interactive heart age tools may be helpful as a communication tool to initiate lifestyle change to reduce risk factors. However, absolute risk should be used instead of heart age to enable informed decision making about medication, to avoid unnecessary treatment of low risk people. Evidence-based decision aids that improve patient understanding of absolute risk should be considered as alternatives to heart age calculators for lifestyle and medication decisions.

  7. Improved accuracy for label-free absolute quantification of proteome by combining the Absolute Protein EXpression profiling algorithm and summed tandem mass spectrometric total ion current.

    Science.gov (United States)

    Wu, Qi; Shan, Yichu; Qu, Yanyan; Jiang, Hao; Yuan, Huiming; Liu, Jianxi; Zhang, Shen; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2014-01-07

    Proteome scale absolute quantification is fundamental for the quantitative understanding of an organism. The unsatisfactory accuracy for protein abundance estimation of current algorithms has been partially improved by the Absolute Protein EXpression profiling (APEX) algorithm, which implements the prior expectations of peptides' appearances in the calculation of protein abundances. However, the abundance feature (AF) in APEX is the spectral count (SC); an AF suffers from a narrow dynamic range, thus, unsatisfactory accuracy. Therefore, we adopted another tandem mass spectrometric (MS/MS) level AF called Summed MS/MS Total ion current (SMT), which cumulates the MS/MS fragment intensities rather than simply counting the MS/MS spectra, to surmount this particular deficiency. The combination of APEX and SMT (abbreviated as APEX-SMT) is capable of improving the accuracy of absolute quantification by reducing the average relative deviation by ~55-85% compared to that of APEX, through a series of tests on the Universal Proteomics Standard sample with a dynamic range of 5 orders of magnitude (UPS2). The algorithm could also be used for relative quantification. When applied to the relative quantification of a publicly available benchmark dataset, APEX-SMT could provide comparable accuracy to APEX. All these results suggest that APEX-SMT is a promising alternative to APEX for proteome quantification.

  8. Directly relating gas-phase cluster measurements to solution-phase hydrolysis, the absolute standard hydrogen electrode potential, and the absolute proton solvation energy.

    Science.gov (United States)

    Donald, William A; Leib, Ryan D; O'Brien, Jeremy T; Williams, Evan R

    2009-06-08

    Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M(H(2)O)(24)(2+)(g) + e(-)(g)-->M(H(2)O)(24)(+)(g) and 2) M(H(2)O)(24)(2+)(g) + e(-)(g)-->MOH(H(2)O)(23)(+)(g) + H(g) and the hydrogen atom affinities of MOH(H(2)O)(23)(+)(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e(-)(g) (standard deviation of 0.02 V) and a real proton solvation free energy of -265 kcal mol(-1) are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution.

  9. Absolute Calibration of Si iRMs used for Measurements of Si Paleo-nutrient proxies

    Science.gov (United States)

    Vocke, R. D., Jr.; Rabb, S. A.

    2016-12-01

    Silicon isotope variations (reported as δ30Si and δ29Si, relative to NBS28) in silicic acid dissolved in ocean waters, in biogenic silica and in diatoms are extremely informative paleo-nutrient proxies. The resolution and comparability of such measurements depend on the quality of the isotopic Reference Materials (iRMs) defining the delta scale. We report new absolute Si isotopic measurements on the iRMs NBS28 (RM 8546 - Silica Sand), Diatomite, and Big Batch using the Avogadro measurement approach and comparing them with prior assessments of these iRMs. The Avogadro Si measurement technique was developed by the German Physikalish-Technische Bundesanstalt (PTB) to provide a precise and highly accurate method to measure absolute isotopic ratios in highly enriched 28Si (99.996%) material. These measurements are part of an international effort to redefine the kg and mole based on the Planck constant h and the Avogadro constant NA, respectively (Vocke et al., 2014 Metrologia 51, 361, Azuma et al., 2015 Metrologia 52 360). This approach produces absolute Si isotope ratio data with lower levels of uncertainty when compared to the traditional "Atomic Weights" method of absolute isotope ratio measurement calibration. This is illustrated in Fig. 1 where absolute Si isotopic measurements on SRM 990, separated by 40+ years of advances in instrumentation, are compared. The availability of this new technique does not say that absolute Si isotopic ratios are or ever will be better for normal Si isotopic measurements when seeking isotopic variations in nature, because they are not. However, by determining the absolute isotopic ratios of all the Si iRM scale artifacts, such iRMs become traceable to the metric system (SI); thereby automatically conferring on all the artifact-based δ30Si and δ29Si measurements traceability to the base SI unit, the mole. Such traceability should help reduce the potential of bias between different iRMs and facilitate the replacement of delta

  10. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  11. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    Science.gov (United States)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  12. Application of x-ray fluorescence (XRF) absolute analysis method for silica refractories

    International Nuclear Information System (INIS)

    Asakura, Hideo; Yamada, Yasujiro; Kansai, Kouhei; Tomatsu, Ichirou; Murata, Mamoru

    2015-01-01

    X-ray fluorescence (XRF) analysis is a rapid and precise quantitative analytical method for the determination of major and trace elements in many industries and academics. XRF analytical values are relative due to the use of the calibration curves calculated from measuring the reference standard materials such as Japanese Refractory Reference Materials (JRRM) series with certified values determined by wet chemical analysis. The development of the XRF analytical method from relative to absolute analysis will help much to determine the absolute values of samples from the fields where reference standard samples have not been prepared, and thus can be applied widely in many industries. The implement of the absolute XRF analysis for silica refractories requires high purity reagents and/or reference standard solution for the binary basic calibration curve, and theoretical matrix correction coefficients for the multi-components silica refractories analysis. The reproducibility and repeatability of this method for Al 2 O 3 5 mass% sample were 0.009 and 0.006 mass% in Al 2 O 3 and showed better values that those of ICP-AES recognized as an absolute method in JIS R 2212-2, which yielded 0.028 and 0.031 mass%, respectively. The XRF absolute analysis for JRRM 200 series, 201a and 205a does not show a bias but coincides with their certified values. (author)

  13. Antiausterity activity of arctigenin enantiomers: importance of (2R,3R)-absolute configuration.

    Science.gov (United States)

    Awale, Suresh; Kato, Mamoru; Dibwe, Dya Fita; Li, Feng; Miyoshi, Chika; Esumi, Hiroyasu; Kadota, Shigetoshi; Tezuka, Yasuhiro

    2014-01-01

    From a MeOH extract of powdered roots of Wikstroemia indica, six dibenzyl-gamma-butyrolactone-type lignans with (2S,3S)-absolute configuration [(+)-arctigenin (1), (+)-matairesinol (2), (+)-trachelogenin (3), (+)-nortrachelogenin (4), (+)-hinokinin (5), and (+)-kusunokinin (6)] were isolated, whereas three dibenzyl-gamma-butyrolactone-type lignans with (2R,3R)-absolute configuration [(-)-arctigenin (1*), (-)-matairesinol (2*), (-)-trachelogenin (3*)] were isolated from Trachelospermum asiaticum. The in vitro preferential cytotoxic activity of the nine compounds was evaluated against human pancreatic PANC-1 cancer cells in nutrient-deprived medium (NDM), but none of the six lignans (1-6) with (2S,3S)-absolute configuration showed preferential cytotoxicity. On the other hand, three lignans (1*-3*) with (2R,3R)-absolute configuration exhibited preferential cytotoxicity in a concentration-dependent manner with PC50 values of 0.54, 6.82, and 5.85 microM, respectively. Furthermore, the effect of (-)- and (+)-arctigenin was evaluated against the activation of Akt, which is a key process in the tolerance to nutrition starvation. Interestingly, only (-)-arctigenin (1*) strongly suppressed the activation of Akt. These results indicate that the (2R,3R)-absolute configuration of (-)-enantiomers should be required for the preferential cytotoxicity through the inhibition of Akt activation.

  14. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Santos, Emilie M.M.; Yoo, Albert J.; Beenen, Ludo F.; Majoie, Charles B.; Berkhemer, Olvert A.; Blanken, Mark D. den; Wismans, Carrie; Niessen, Wiro J.; Marquering, Henk A.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  15. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  16. Computer-aided-design-model-assisted absolute three-dimensional shape measurement.

    Science.gov (United States)

    Li, Beiwen; Bell, Tyler; Zhang, Song

    2017-08-20

    Conventional three-dimensional (3D) shape measurement methods are typically generic to all types of objects. Yet, for many measurement conditions, such a level of generality is inessential when having the preknowledge of the object geometry. This paper introduces a novel adaptive algorithm for absolute 3D shape measurement with the assistance of the object computer-aided-design (CAD) model. The proposed algorithm includes the following major steps: (1) export the 3D point cloud data from the CAD model; (2) transform the CAD model into the camera perspective; (3) obtain a wrapped phase map from three phase-shifted fringe images; and (4) retrieve absolute phase and 3D geometry assisted by the CAD model. We demonstrate that if object CAD models are available, such an algorithm is efficient in recovering absolute 3D geometries of both simple and complex objects with only three phase-shifted fringe images.

  17. Absolute and convective instabilities in two-dimensional free-electron lasers

    International Nuclear Information System (INIS)

    Kwan, T.J.T.; Cary, J.R.

    1981-01-01

    Computer simulations of the free-electron laser have been carried out using a two-and-one-half dimensional fully electromagnetic relativistic particle code. It has been found that waves propagating obliquely with respect to the electron beam are always unstable with appreciable growth rates and, therefore, mode competition is an important consideration in the design of free-electron lasers. Furthermore, electromagnetic waves with group velocities opposite to the direction of electron beam propagation can be absolutely unstable. It is shown that the absolutely unstable waves can completely disrupt the electron beam and any laser oscillaton; therefore, they are extremely detrimental to the operation of free electron lasers. However, it has been found that one can stabilize the absolute instability by taking particular precautions in the design of free-electron lasers

  18. The need for an established allocation method when assessing absolute sustainability on a product level

    DEFF Research Database (Denmark)

    Ryberg, Morten; Owsianiak, Mikolaj; Hauschild, Michael Zwicky

    2015-01-01

    Assessment of absolute sustainability within life cycle assessment (LCA) framework is operational on the country scale. However, it is difficult to apply the existing approaches to products, which are typically the scope of LCAs. How should we assess whether a chair is (absolutely) sustainable......? If we assess the life cycle and relate the impact scores to the remaining capacity available for impacts, there is a risk that all products are seen absolutely sustainable. In addition, how should we decide on who can use the remaining capacity? To address these issues an allocation method is proposed...... for dividing the remaining capacity between and within product groups. The method is a two- step method developed based on the annual consumption pattern of an average person in the country and share of product sub-groups in the group. For example, in the first allocation step, the remaining capacity share...

  19. Absolute Hydration Free Energy of Proton from First Principles Electronic Structure Calculations

    International Nuclear Information System (INIS)

    Zhan, Chang-Guo; Dixon, David A.

    2001-01-01

    The absolute hydration free energy of the proton, DGhyd298(H+), is one of the fundamental quantities for the thermodynamics of aqueous systems. Its exact value remains unknown despite extensive experimental and computational efforts. We report a first-principles determination of DGhyd298(H+) by using the latest developments in electronic structure theory and massively parallel computers. DGhyd298(H+) is accurately predicted to be -262.4 kcal/mol based on high-level, first-principles solvation-included electronic structure calculations. The absolute hydration free energies of other cations can be obtained by using appropriate available thermodynamic data in combination with this value. The high accuracy of the predicted absolute hydration free energy of proton is confirmed by applying the same protocol to predict DGhyd298(Li+)

  20. An immune response study of oakmoss absolute and its constituents atranol and chloroatranol

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte Menné; Nielsen, Morten Milek; Gimenéz-Arnau, Elena

    2014-01-01

    BACKGROUND: Atranol and chloroatranol are the main allergens of oakmoss absolute. However, the immune responses induced by these substances are poorly characterized. OBJECTIVES: To characterize immune responses induced by atranol, chloroatranol and oakmoss absolute in mice. METHODS: Mice were...... sensitized and challenged with various concentrations of atranol, chloroatranol, and oakmoss absolute. The immune responses were analysed as B cell infiltration, T cell proliferation in the draining lymph nodes, and expression of interleukin (IL)-18, IL-1β and tumour necrosis factor-α in skin...... induced sensitization. In parallel, atranol and chloroatranol elicited challenge reactions following sensitization with oakmoss. The magnitude of the immune response to the three allergens increased in the following order: atranol, chloroatranol, and oakmoss. The expression of proinflammatory cytokines...

  1. ABSOLUTE GROWTH AND BIOMASS OF Gracilaria sp. THAT CULTIVATED UNDER DIFFERENT DEPTHS

    Directory of Open Access Journals (Sweden)

    Nurlaila Ervina Herliany

    2018-02-01

    Full Text Available There is significant increasing of seaweeds demand over the years that affect the development of seaweeds farming in Indonesia. Gracilaria sp. is one of the species that cultivated in Indonesia. There are some factors that affect the successful of seaweeds cultivation, one of them is cultivation depth. The research was carried out to study the effect of different depth on absolute growth and biomass of Gracilaria sp. Gracilaria sp. was cultivated under three different depths (30, 45 and 60 cm. The result shows that absolute growth and biomass were influenced by cultivation depth. The best treatment was cultivation at 30 cm of depth. Water quality measurements shows that research location is suitable for the growth of seaweeds.Keywords : Absolute growth, Biomass, Cultivation depths, Gracilaria sp

  2. Preservation of absolute pitch after right amygdalohippocampectomy for a pianist with TLE.

    Science.gov (United States)

    Suriadi, Meilia M; Usui, Keiko; Tottori, Takayasu; Terada, Kiyohito; Fujitani, Shigeru; Umeoka, Shuichi; Usui, Naotaka; Baba, Kouichi; Matsuda, Kazumi; Inoue, Yushi

    2015-01-01

    Absolute pitch (AP) ability is a rare musical phenomenon. In the literature, it has been suggested that the relative specialization for pitch processing is in the right temporal lobe in the non-AP population. Since the anatomic basis for absolute pitch is not fully understood and cases of temporal lobe epilepsy of AP possessors are extremely rare, applicability of resection as a treatment of epilepsy in this particular area should be evaluated with caution. In the present study, we examined an AP possessor who suffered from medically refractory temporal lobe epilepsy and underwent right selective amygdalohippocampectomy (SAH). The SAH procedure clearly avoided disturbing important structures for AP, inasmuch as postsurgically she preserved her AP ability and was seizure-free. She did well post-operatively in the test of pure sine wave tones with short reaction time, which could be identified as "true" absolute pitch. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Fuzzy logic based anaesthesia monitoring systems for the detection of absolute hypovolaemia.

    Science.gov (United States)

    Mansoor Baig, Mirza; Gholamhosseini, Hamid; Harrison, Michael J

    2013-07-01

    Anaesthesia monitoring involves critical diagnostic tasks carried out amongst lots of distractions. Computers are capable of handling large amounts of data at high speed and therefore decision support systems and expert systems are now capable of processing many signals simultaneously in real time. We have developed two fuzzy logic based anaesthesia monitoring systems; a real time smart anaesthesia alarm system (RT-SAAM) and fuzzy logic monitoring system-2 (FLMS-2), an updated version of FLMS for the detection of absolute hypovolaemia. This paper presents the design aspects of these two systems which employ fuzzy logic techniques to detect absolute hypovolaemia, and compares their performances in terms of usability and acceptability. The interpretation of these two systems of absolute hypovolaemia was compared with clinicians' assessments using Kappa analysis, RT-SAAM K=0.62, FLMS-2 K=0.75; an improvement in performance by FLMS-2. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Differences in platelet indices between healthy Han population and Tibetans in China.

    Directory of Open Access Journals (Sweden)

    Qian Niu

    Full Text Available INTRODUCTION: The present data on the evaluation of platelet (PLT parameters in Chinese Han population and Tibetans are still limited. The objective of this study was to determine the differences in common PLT indices between Han population and Tibetans in China, through a large-scale investigation of healthy people. METHODS: 2131 Han people from Chengdu Plain, 1099 Tibetans from Qinghai-Tibet Plateau and 956 Plateau Han migrants were included in this study. All the subjects were healthy people through the health screening. PLT indices were measured with Sysmex XE-2100 and XT-1800i blood cell automatic analyzer. RESULTS: Compared with Han people in Chendu Plain, Tibetans had higher PLT count (P<0.01 but lower mean platelet volume (MPV, platelet distribution width (PDW and platelet-large cell ratio (P-LCR (P<0.01; while Plateau Han migrants had lower PLT count, MPV and P-LCR (P<0.05. When compared with Tibetans, Plateau Han migrants had lower levels of mean PLT count but higher PDW and P-LCR (P<0.05. CONCLUSIONS: There are ethnic differences in PLT indices between Chinese Han population and Tibetans. Based on this finding, it would be reasonable to conduct formal prospective studies to determine the clinical significance of these differences and to explore the effects of genetic background on these indices.

  5. HEMATOPOIETIC PROGENITOR CELLS AS A PREDICTIVE OF CD34+ ENUMERATION PRIOR TO PERIPHERAL BLOOD STEM CELLS HARVESTING

    Directory of Open Access Journals (Sweden)

    Z. Zulkafli

    2014-09-01

    Full Text Available Background: To date, the CD34+ cell enumeration has relied predominantly on flow cytometry technique. However, flow cytometry is time consuming and operator dependent. The application of the hematopoietic progenitor cells (HPCs channel in Sysmex XE-2100, a fully automated hematology analyzer offers an alternative approach, which is with minimal sample manipulation and less operator dependent. This study evaluates the utility of HPC counts as a predictive of CD34+ enumeration prior to peripheral blood stem cells harvesting. Materials and methods: HPC, CD34+, white blood cell (WBC, reticulocytes (retic, immature platelet fraction (IPF and immature reticulocyte fraction (IRF were determined in 61 samples from 19 patients with hematological malignancies (15 lymphoma and 4 multiple myeloma patients at Hospital Universiti Sains Malaysia (Hospital USM who had received granulocyte-colony stimulating factor (G-CSF and planned for autologous transplantation. Results: CD34+ count showed strong and significant correlation with HPC. The receiver operating characteristics (ROC curve analysis revealed that HPC count > 21.5 x 106 / L can predicts a pre harvest CD34+ count of >20 x 106 / L with sensitivity of 77%, specificity of 64% and area under the curve (AUC of 0.802. Conclusion: We concluded that HPC count can be a useful potential parameter in optimizing timing for CD34+ enumeration prior to leukapheresis.

  6. Effect of placenta previa on neonatal respiratory disorders and amniotic lamellar body counts at 36-38weeks of gestation.

    Science.gov (United States)

    Tsuda, Hiroyuki; Kotani, Tomomi; Sumigama, Seiji; Mano, Yukio; Hua, Li; Hayakawa, Hiromi; Hayakawa, Masahiro; Sato, Yoshiaki; Kikkawa, Fumitaka

    2014-01-01

    Pregnancies with placenta previa are significantly associated with preterm delivery and cesarean section. Therefore particular attention should be paid to the incidence of neonatal respiratory disorders in pregnancies with placenta previa. The purpose of this study is to examine the relationship between placenta previa and neonatal respiratory disorders, including respiratory distress syndrome (RDS) and transient tachypnea of the newborn (TTN), and to evaluate the impact of placenta previa on the amniotic lamellar body count (LBC) values. We analyzed the data from 186 registered elective cesarean cases without fetal or maternal complications at 36-38weeks of gestation. Amniotic fluid samples were analyzed immediately without centrifugation, and the LBC was measured using a platelet channel on the Sysmex XE-2100. RDS was present in four neonates (2.2%) and TTN in 12 neonates (6.5%). The rate of TTN was significantly higher and the LBC values were significantly lower in the placenta previa group than in the control group (P=0.002 and P=0.024). The adjusted odds ratio for neonatal TTN was 7.20 (95% confidence interval: 6.58-7.88) among females with placenta previa. In placenta previa, warning bleeding was a significant factor protecting against neonatal respiratory disorders (P=0.046). Placenta previa in itself is a risk factor for neonatal TTN. When an elective cesarean section is performed in cases with uncomplicated placenta previa, special care should be taken to monitor for neonatal TTN even at 36-38weeks of gestation. © 2013.

  7. Six-day stability of erythrocyte and reticulocyte parameters in-vitro: a comparison of blood samples from healthy, iron-deficient, and thalassemic individuals.

    Science.gov (United States)

    Sudmann-Day, Åshild A; Piehler, Armin; Klingenberg, Olav; Urdal, Petter

    2015-05-01

    Stability for up to 6 days' storage of erythrocyte and reticulocyte parameters in samples from iron-deficient and thalassemic individuals has not yet been reported. This lack of knowledge challenges evaluation of the full blood count in referral samples for hemoglobinopathy evaluation. We therefore hereby present such sample stability data. We included fresh (less than 4 hours old) blood samples from eight healthy, eight iron-deficient, and 11 thalassemic individuals. A full blood count, including reticulocyte parameters, was performed on a Sysmex XE-2100 once daily during a 6-day storage period at room temperature. For healthy individuals, we also studied stability of refrigerated samples and investigated analytical and biological variation. Hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin were stable for 6 days in all diagnostic groups. Mean corpuscular volume increased less in samples from iron-deficient individuals while the number of reticulocytes increased more in samples from thalassemic, as compared to healthy individuals. Ret-He stability depended on its baseline value. Within-person biological variation in samples from healthy individuals was low both for erythrocyte parameters and for reticulocyte hemoglobin, while higher for reticulocyte counts. Results for hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin are reliable in hemoglobinopathy investigation of referred samples for up to 6 days. Storage time-dependent changes of other erythrocyte and reticulocyte parameters in blood samples from iron-deficient and thalassemic individuals differ from those of healthy individuals.

  8. Timing of Peripheral Blood Stem Cell Yield: Comparison of Alternative Methods with the Classic Method for CD34+ Cell Determination

    Directory of Open Access Journals (Sweden)

    I. Fatorova

    2014-01-01

    Full Text Available Hematopoietic stem cells (HSCs, still represent a certain mystery in biology, have a unique property of dividing into equal cells and repopulating the hematopoietic tissue. This potential enables their use in transplantation treatments. The quality of the HSC grafts for transplantation is evaluated by flow cytometric determination of the CD34+ cells, which enables optimal timing of the first apheresis and the acquisition of maximal yield of the peripheral blood stem cells (PBSCs. To identify a more efficient method for evaluating CD34+ cells, we compared the following alternative methods with the reference method: hematopoietic progenitor cells (HPC enumeration (using the Sysmex XE-2100 analyser, detection of CD133+ cells, and quantification of aldehyde dehydrogenase activity in the PBSCs. 266 aphereses (84 patients were evaluated. In the preapheretic blood, the new methods produced data that were in agreement with the reference method. The ROC curves have shown that for the first-day apheresis target, the optimal predictive cut-off value was 0.032 cells/mL for the HPC method (sensitivity 73.4%, specificity 69.3%. HPC method exhibited a definite practical superiority as compared to other methods tested. HPC enumeration could serve as a supplementary method for the optimal timing of the first apheresis; it is simple, rapid, and cheap.

  9. Validity of Point-of-Care Testing with Mission Plus Hemoglobin in Detecting Anemia

    Directory of Open Access Journals (Sweden)

    S Maria Awaluddin

    2015-06-01

    Full Text Available Background: Point-of-care testing, POCT, was widely used to assess hemoglobin status before proceeding with the confirmation test. Our study aimed to assess the validity of Mission® Plus Hb in detecting hemoglobin levels in a general population compared with a standard laboratory hematology analyser as the gold standard. Methods: Two types of samples, capillary and venous blood, were collected from all respondents by trained nurses. Both blood samples were tested using Mission® Plus while the remaining venous blood in EDTA test tubes was sent to the reference laboratory. Results: A total of 622 respondents participated in this study, 75% of them females. The mean Hb tested from capillary blood using Mission® Plus Hb was 11.80±2.02g/dl. For venous blood, the mean Hb concentrations using Mission® Plus Hb and Sysmex XE-2100 hematology analyser were 12.16±1.84g/dl and 13.07±1.87g/dl, respectively. Sensitivity and specificity in detecting anemia from venous samples were 98.8% and 73.4% respectively. Positive Predictive Value (PPV was 58.5%, while Negative Predictive Value (NPV was 99.4%. Conclusion: The findings of moderate PPV should alert the programme managers to the importance of a confirmatory test following screening using Mission® Plus Hb.

  10. Absolutely Fabulous!

    DEFF Research Database (Denmark)

    Hjorth, Daniel

    2013-01-01

    Purpose – This paper seeks to apply a processual thinking of subjectivity in the study of “becoming entrepreneur”. Design/methodology/approach – Through analysing Foucault's idea of subjectification, by the help of Deleuze's comments and elaborations, the paper seeks to clarify one opacity in ent...

  11. Absolute Zero.

    Science.gov (United States)

    Jones, Rebecca

    1997-01-01

    So far the courts have supported most schools' zero-tolerance policies--even those banning toy weapons, over-the-counter drugs, and unseemly conduct. However, wide-ranging get-tough policies can draw criticism. Policy experts advise school boards to ask the community, decide what people want, allow some wiggle room, create an appeals process,…

  12. A geometrically exact beam element based on the absolute nodal coordinate formulation

    Energy Technology Data Exchange (ETDEWEB)

    Gerstmayr, Johannes [Linz Center of Mechatronics GmbH (Austria)], E-mail: Johannes.gerstmayr@jku.at; Matikainen, Marko K., E-mail: marko.matikainen@lut.fi; Mikkola, Aki M. [Lappeenranta University of Technology, Department of Mechanical Engineering, Institute of Mechatronics and Virtual Engineering (Finland)], E-mail: aki.mikkola@lut.fi

    2008-11-15

    In this study, Reissner's classical nonlinear rod formulation, as implemented by Simo and Vu-Quoc by means of the large rotation vector approach, is implemented into the framework of the absolute nodal coordinate formulation. The implementation is accomplished in the planar case accounting for coupled axial, bending, and shear deformation. By employing the virtual work of elastic forces similarly to Simo and Vu-Quoc in the absolute nodal coordinate formulation, the numerical results of the formulation are identical to those of the large rotation vector formulation. It is noteworthy, however, that the material definition in the absolute nodal coordinate formulation can differ from the material definition used in Reissner's beam formulation. Based on an analytical eigenvalue analysis, it turns out that the high frequencies of cross section deformation modes in the absolute nodal coordinate formulation are only slightly higher than frequencies of common shear modes, which are present in the classical large rotation vector formulation of Simo and Vu-Quoc, as well. Thus, previous claims that the absolute nodal coordinate formulation is inefficient or would lead to ill-conditioned finite element matrices, as compared to classical approaches, could be refuted. In the introduced beam element, locking is prevented by means of reduced integration of certain parts of the elastic forces. Several classical large deformation static and dynamic examples as well as an eigenvalue analysis document the equivalence of classical nonlinear rod theories and the absolute nodal coordinate formulation for the case of appropriate material definitions. The results also agree highly with those computed in commercial finite element codes.

  13. A geometrically exact beam element based on the absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Gerstmayr, Johannes; Matikainen, Marko K.; Mikkola, Aki M.

    2008-01-01

    In this study, Reissner's classical nonlinear rod formulation, as implemented by Simo and Vu-Quoc by means of the large rotation vector approach, is implemented into the framework of the absolute nodal coordinate formulation. The implementation is accomplished in the planar case accounting for coupled axial, bending, and shear deformation. By employing the virtual work of elastic forces similarly to Simo and Vu-Quoc in the absolute nodal coordinate formulation, the numerical results of the formulation are identical to those of the large rotation vector formulation. It is noteworthy, however, that the material definition in the absolute nodal coordinate formulation can differ from the material definition used in Reissner's beam formulation. Based on an analytical eigenvalue analysis, it turns out that the high frequencies of cross section deformation modes in the absolute nodal coordinate formulation are only slightly higher than frequencies of common shear modes, which are present in the classical large rotation vector formulation of Simo and Vu-Quoc, as well. Thus, previous claims that the absolute nodal coordinate formulation is inefficient or would lead to ill-conditioned finite element matrices, as compared to classical approaches, could be refuted. In the introduced beam element, locking is prevented by means of reduced integration of certain parts of the elastic forces. Several classical large deformation static and dynamic examples as well as an eigenvalue analysis document the equivalence of classical nonlinear rod theories and the absolute nodal coordinate formulation for the case of appropriate material definitions. The results also agree highly with those computed in commercial finite element codes

  14. Noninvasive absolute cerebral oximetry with frequency-domain near-infrared spectroscopy

    Science.gov (United States)

    Hallacoglu, Bertan

    Near-infrared spectroscopy (NIRS) measurements of absolute concentrations of oxy-hemoglobin and deoxy-hemoglobin in the human brain can provide critical information about cerebral physiology in terms of cerebral blood volume, blood flow, oxygen delivery, and metabolic rate of oxygen. We developed several frequency domain NIRS data acquisition and analysis methods aimed at absolute measurements of hemoglobin concentration and saturation in cerebral tissue of adult human subjects. Extensive experimental investigations were carried out in various homogenous and two-layered tissue-mimicking phantoms, and biological tissues. The advantages and limitations of commonly used homogenous models and inversion strategies were thoroughly investigated. Prior to human subjects, extensive studies were carried out in in vivo animal models. In rabbits, absolute hemoglobin oxygen desaturation was shown to depend strongly on surgically induced testicular torsion. Methods developed in this study were then adapted for measurements in the rat brain. Absolute values were demonstrated to discern cerebrovascular impairment in a rat model of diet-induced vascular cognitive impairment. These results facilitated the development of clinically useful optical measures of cerebrovascular health. In a large group of human subjects, employing a homogeneous model for absolute measurements was shown to be reliable and robust. However, it was also shown to be limited due to the relatively thick extracerebral tissue. The procedure we develop in this work and the thesis thereof performs a nonlinear inversion procedure with six unknown parameters with no other prior knowledge for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and

  15. Fluctuation theorems in feedback-controlled open quantum systems: Quantum coherence and absolute irreversibility

    Science.gov (United States)

    Murashita, Yûto; Gong, Zongping; Ashida, Yuto; Ueda, Masahito

    2017-10-01

    The thermodynamics of quantum coherence has attracted growing attention recently, where the thermodynamic advantage of quantum superposition is characterized in terms of quantum thermodynamics. We investigate the thermodynamic effects of quantum coherent driving in the context of the fluctuation theorem. We adopt a quantum-trajectory approach to investigate open quantum systems under feedback control. In these systems, the measurement backaction in the forward process plays a key role, and therefore the corresponding time-reversed quantum measurement and postselection must be considered in the backward process, in sharp contrast to the classical case. The state reduction associated with quantum measurement, in general, creates a zero-probability region in the space of quantum trajectories of the forward process, which causes singularly strong irreversibility with divergent entropy production (i.e., absolute irreversibility) and hence makes the ordinary fluctuation theorem break down. In the classical case, the error-free measurement ordinarily leads to absolute irreversibility, because the measurement restricts classical paths to the region compatible with the measurement outcome. In contrast, in open quantum systems, absolute irreversibility is suppressed even in the presence of the projective measurement due to those quantum rare events that go through the classically forbidden region with the aid of quantum coherent driving. This suppression of absolute irreversibility exemplifies the thermodynamic advantage of quantum coherent driving. Absolute irreversibility is shown to emerge in the absence of coherent driving after the measurement, especially in systems under time-delayed feedback control. We show that absolute irreversibility is mitigated by increasing the duration of quantum coherent driving or decreasing the delay time of feedback control.

  16. Genomic DNA-based absolute quantification of gene expression in Vitis.

    Science.gov (United States)

    Gambetta, Gregory A; McElrone, Andrew J; Matthews, Mark A

    2013-07-01

    Many studies in which gene expression is quantified by polymerase chain reaction represent the expression of a gene of interest (GOI) relative to that of a reference gene (RG). Relative expression is founded on the assumptions that RG expression is stable across samples, treatments, organs, etc., and that reaction efficiencies of the GOI and RG are equal; assumptions which are often faulty. The true variability in RG expression and actual reaction efficiencies are seldom determined experimentally. Here we present a rapid and robust method for absolute quantification of expression in Vitis where varying concentrations of genomic DNA were used to construct GOI standard curves. This methodology was utilized to absolutely quantify and determine the variability of the previously validated RG ubiquitin (VvUbi) across three test studies in three different tissues (roots, leaves and berries). In addition, in each study a GOI was absolutely quantified. Data sets resulting from relative and absolute methods of quantification were compared and the differences were striking. VvUbi expression was significantly different in magnitude between test studies and variable among individual samples. Absolute quantification consistently reduced the coefficients of variation of the GOIs by more than half, often resulting in differences in statistical significance and in some cases even changing the fundamental nature of the result. Utilizing genomic DNA-based absolute quantification is fast and efficient. Through eliminating error introduced by assuming RG stability and equal reaction efficiencies between the RG and GOI this methodology produces less variation, increased accuracy and greater statistical power. © 2012 Scandinavian Plant Physiology Society.

  17. Absolute quantification of Na + bound fraction by double-quantum filtered 23Na NMR spectroscopy

    Science.gov (United States)

    Mouaddab, Mohamed; Foucat, Loïc; Donnat, Jean Pierre; Renou, Jean Pierre; Bonny, Jean Marie

    2007-11-01

    A method is described for the absolute quantification of double-quantum filtered spectra of spin-3/2 nuclei ( 23Na). The method was tested on a model system, a cationic exchange resin for which the number of Na + binding sites was quantitatively controlled. The theoretical and experimental approaches were validated on samples with different Na + concentrations. An excellent agreement between the results obtained by double-quantum and single-quantum acquisitions was found. This method paves the way for absolute quantification of both bound and free fractions of Na +, which are determining factors in the characterization of salted/brined/dried food products.

  18. Management of High Blood Pressure in Those without Overt Cardiovascular Disease Utilising Absolute Risk Scores

    Directory of Open Access Journals (Sweden)

    Mark R. Nelson

    2011-01-01

    Full Text Available Increasing blood pressure has a continuum of adverse risk for cardiovascular events. Traditionally this single measure was used to determine who to treat and how vigorously. However, estimating absolute risk rather than measurement of a single risk factor such as blood pressure is a superior method to identify who is most at risk of having an adverse cardiovascular event such as stroke or myocardial infarction, and therefore who would most likely benefit from therapeutic intervention. Cardiovascular disease (CVD risk calculators must be used to estimate absolute risk in those without overt CVD as physician estimation is unreliable. Incorporation into usual practice and limitations of the strategy are discussed.

  19. Ten-year absolute risk of osteoporotic fractures according to BMD T score at menopause

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Vestergaard, Peter; Rud, Bo

    2006-01-01

    was 10.9% as opposed to an expected risk of 5.7%. Relative risk gradients were similar to those of the recent meta-analysis. CONCLUSIONS: In healthy women, examined in the first year or two after menopause, 10-year fracture risk was higher at each level of BMD T score than expected from the model...... by Kanis et al. Inclusion of HRT users in the cohorts used may have led to higher BMD values and lower absolute fracture risk in the Kanis model. These longitudinal data can be used directly in estimating absolute fracture risk in untreated north European women from BMD at menopause....

  20. Exploring the Saturation Levels of Stimulated Raman Scattering in the Absolute Regime

    International Nuclear Information System (INIS)

    Michel, D. T.; Depierreux, S.; Tassin, V.; Stenz, C.; Labaune, C.

    2010-01-01

    This Letter reports new experimental results that evidence the transition between the absolute and convective growth of stimulated Raman scattering (SRS). Significant reflectivities were observed only when the instability grows in the absolute regime. In this case, saturation processes efficiently limit the SRS reflectivity that is shown to scale linearly with the laser intensity, and the electron density and temperature. Such a scaling agrees with the one established by T. Kolber et al.[Phys. Fluids B 5, 138 (1993)] and B Bezzerides et al.[Phys. Rev. Lett. 70, 2569 (1993)], from numerical simulations where the Raman saturation is due to the coupling of electron plasma waves with ion waves dynamics.

  1. Estudi de les dimensions absolutes de ballarins professionals d'elit de ballet

    OpenAIRE

    Betancourt León, Hamlet; Aréchiga Viramontes, Julieta; Ramírez García, Carlos; Díaz Sánchez, María

    2009-01-01

    Les diferències o similituds referides a les dimensions absolutes d'un grup de ballarins de ballet versus ballarins de dansa moderna i folklòrica són indicadors de variabilitat o homogeneïtat corporal i expressió del volum espacial que ocupa un grup de ballarins. Aquest treball es va proposar d'analitzar les similituds i diferències cineantropomètriques de les dimensions absolutes entre els ballarins professionals d'elit de ballet respecte dels de dansa moderna i folklòrica. Es van estudiar a...

  2. Improvement Of The Absolute Activity Determination Technique Of '125I In The Thyroid

    International Nuclear Information System (INIS)

    Pelled, O.; German, U.; Alfassi, Z.

    1999-01-01

    A method for absolute determination of the activity of a 125 I source based on the counting rate values of the 27 keV photons and the 54 keV coincidence photo-peak is given in the literature. We had shown in previous works, that this method, within certain limitations, diminishes the geometry dependence of the activity determination for 125 I sources and for measuring the uptake of 125 I in human thyroid. In the present work we present a farther improvement of the accuracy of the absolute determination method

  3. Absolute linear thermal-expansion measurements on copper and aluminum from 5 to 320 K

    International Nuclear Information System (INIS)

    Kroeger, F.R.; Swenson, C.A.

    1977-01-01

    A linear absolute dilatometer based on a three-terminal parallel-plate capacitor design has been used to obtain thermal expansion data for high-purity copper and aluminum from 5 to 320 K. These data have an absolute accuracy of +- 0.1% above 20 K for copper and above 30 K for aluminum, and agree well with published data at the higher temperatures. The disagreement which exists with other data below 5 K for copper and below 15 K for aluminum is believed to be sample dependent, but the mechanism is not known. The aluminum results in this region depend on the state of annealing of the sample

  4. A highly accurate absolute gravimetric network for Albania, Kosovo and Montenegro

    Science.gov (United States)

    Ullrich, Christian; Ruess, Diethard; Butta, Hubert; Qirko, Kristaq; Pavicevic, Bozidar; Murat, Meha

    2016-04-01

    The objective of this project is to establish a basic gravity network in Albania, Kosovo and Montenegro to enable further investigations in geodetic and geophysical issues. Therefore the first time in history absolute gravity measurements were performed in these countries. The Norwegian mapping authority Kartverket is assisting the national mapping authorities in Kosovo (KCA) (Kosovo Cadastral Agency - Agjencia Kadastrale e Kosovës), Albania (ASIG) (Autoriteti Shtetëror i Informacionit Gjeohapësinor) and in Montenegro (REA) (Real Estate Administration of Montenegro - Uprava za nekretnine Crne Gore) in improving the geodetic frameworks. The gravity measurements are funded by Kartverket. The absolute gravimetric measurements were performed from BEV (Federal Office of Metrology and Surveying) with the absolute gravimeter FG5-242. As a national metrology institute (NMI) the Metrology Service of the BEV maintains the national standards for the realisation of the legal units of measurement and ensures their international equivalence and recognition. Laser and clock of the absolute gravimeter were calibrated before and after the measurements. The absolute gravimetric survey was carried out from September to October 2015. Finally all 8 scheduled stations were successfully measured: there are three stations located in Montenegro, two stations in Kosovo and three stations in Albania. The stations are distributed over the countries to establish a gravity network for each country. The vertical gradients were measured at all 8 stations with the relative gravimeter Scintrex CG5. The high class quality of some absolute gravity stations can be used for gravity monitoring activities in future. The measurement uncertainties of the absolute gravity measurements range around 2.5 micro Gal at all stations (1 microgal = 10-8 m/s2). In Montenegro the large gravity difference of 200 MilliGal between station Zabljak and Podgorica can be even used for calibration of relative gravimeters

  5. Assignment of absolute stereostructures through quantum mechanics electronic and vibrational circular dichroism calculations.

    Science.gov (United States)

    Dai, Peng; Jiang, Nan; Tan, Ren-Xiang

    2016-01-01

    Elucidation of absolute configuration of chiral molecules including structurally complex natural products remains a challenging problem in organic chemistry. A reliable method for assigning the absolute stereostructure is to combine the experimental circular dichroism (CD) techniques such as electronic and vibrational CD (ECD and VCD), with quantum mechanics (QM) ECD and VCD calculations. The traditional QM methods as well as their continuing developments make them more applicable with accuracy. Taking some chiral natural products with diverse conformations as examples, this review describes the basic concepts and new developments of QM approaches for ECD and VCD calculations in solution and solid states.

  6. Absolute quantitation of proteins by Acid hydrolysis combined with amino Acid detection by mass spectrometry

    DEFF Research Database (Denmark)

    Mirgorodskaya, Olga A; Körner, Roman; Kozmin, Yuri P

    2012-01-01

    Amino acid analysis is among the most accurate methods for absolute quantification of proteins and peptides. Here, we combine acid hydrolysis with the addition of isotopically labeled standard amino acids and analysis by mass spectrometry for accurate and sensitive protein quantitation. Quantitat......Amino acid analysis is among the most accurate methods for absolute quantification of proteins and peptides. Here, we combine acid hydrolysis with the addition of isotopically labeled standard amino acids and analysis by mass spectrometry for accurate and sensitive protein quantitation....... Quantitation of less than 10 fmol of protein standards with errors below 10% has been demonstrated using this method (1)....

  7. Comparison of noninvasive and invasive point-of-care testing methods with reference method for hemoglobin measurement.

    Science.gov (United States)

    Avcioglu, Gamze; Nural, Cemil; Yilmaz, Fatma Meriç; Baran, Pervin; Erel, Özcan; Yilmaz, Gülsen

    2017-08-23

    Rapid and practical point-of-care testing (POCT) devices become more popular, especially in blood donation centers for determining predonation hemoglobin (Hb) concentrations. The purpose of this study was to evaluate accordance between the POCT methods and the venous method as the reference to Hb screening. A total of 353 subjects with no known significant health problems were included in the study. Hb screening was performed by two different POCT methods, a noninvasive method (Haemospect, MBR, Germany) and an invasive method (HemoControl, EKF Diagnostic, Germany), and a venous method as the reference (Sysmex XE-2100, Sysmex Europe, Germany). The obtained results were compared. The sensitivity and the specificity values of the invasive POCT method (83.3%, 87.9%) were higher than the noninvasive POCT method (66.7%, 77.1%). The Bland-Altman analysis was evaluated for both sexes and the bias of the noninvasive POCT method of the males (-0.97 g/dL) was higher than the bias of the invasive POCT method of the males (-0.07 g/dL). We found a better correlation between the invasive POCT method (r = .908) compared with the venous method than the noninvasive POCT method (r = .634). Predonation Hb measurements must be performed with accurate, precise, and practical methods. Although the noninvasive POCT method was practical and painless, it had lower levels of specificity and sensitivity, and more false deferral and pass rates than the invasive POCT method. The POCT methods agreeable to the venous method as the reference might be suitable for Hb screening especially for centers of excessive numbers of blood donation. © 2017 Wiley Periodicals, Inc.

  8. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, preference range, the GEM Premier 3000 measured systematically too low or too high, respectively. Furthermore, in comparison with the other parameters, a therapeutically unacceptable systematic difference (mean of difference: -2.2%, p=0.05) in hematocrit measurement on the GEM Premier 3000 was observed for hematocrit values below 30%. The variance of the readings for the GEM Premier 3000 measurements was at clinically acceptable levels. The GEM Premier 3000 analyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  9. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  10. The dynamic control ratio at the equilibrium point (DCRe): introducing relative and absolute reliability scores.

    Science.gov (United States)

    Alt, Tobias; Knicker, Axel J; Strüder, Heiko K

    2017-04-01

    Analytical methods to assess thigh muscle balance need to provide reliable data to allow meaningful interpretation. However, reproducibility of the dynamic control ratio at the equilibrium point has not been evaluated yet. Therefore, the aim of this study was to compare relative and absolute reliability indices of its angle and moment values with conventional and functional hamstring-quadriceps ratios. Furthermore, effects of familiarisation and angular velocity on reproducibility were analysed. A number of 33 male volunteers participated in 3 identical test sessions. Peak moments (PMs) were determined unilaterally during maximum concentric and eccentric knee flexion (prone) and extension (supine position) at 0.53, 1.57 and 2.62 rad · s -1 . A repeated measure, ANOVA, confirmed systematic bias. Intra-class correlation coefficients and standard errors of measurement indicated relative and absolute reliability. Correlation coefficients were averaged over respective factors and tested for significant differences. All balance scores showed comparable low-to-moderate relative (<0.8-0.9) and good absolute reliability (<10%). Relative reproducibility of dynamic control equilibrium parameters augmented with increasing angular velocity, but not with familiarisation. At 2.62 rad · s -1 , high (moment: 0.906) to moderate (angle: 0.833) relative reliability scores with accordingly high absolute indices (4.9% and 6.4%) became apparent. Thus, the dynamic control equilibrium is an equivalent method for the reliable assessment of thigh muscle balance.

  11. Low geometry counter for the absolute measurement of the activity of alpha-emitting sources

    International Nuclear Information System (INIS)

    Garcia-Torano, E.; Acena, M.L.

    1989-01-01

    A low-geometry counter is described which allows the absolute determination of the activity for alpha-emitting sources. A Si implanted detector is used to obtain the spectrum of the sample. Two samples are measured with this counter and a 2 π gridded ion chamber. The results an their uncertainties for both instruments are discussed. (Author)

  12. Relative and absolute components of leapfrogging in mobile phones by developing countries

    NARCIS (Netherlands)

    James, M.J.

    This paper suggests a novel way of measuring the important concept of leapfrogging in mobile phones. It argues that an adequate measure of leapfrogging needs to include absolute as well as relative components. The new measure is used to measure the performance of around 60 developing countries and

  13. Using the t-distribution to improve the absolute structure assignment with likelihood calculations

    NARCIS (Netherlands)

    Hooft, R.W.W.; Straver, L.H.; Spek, A.L.

    2010-01-01

    The previously described method for absolute structure determination [Hooft, Straver & Spek (2008). J. Appl. Cryst. 41, 96–103] assumes a Gaussian error distribution. The method is now extended to make it robust against poor data with large systematic errors with the introduction of the Student

  14. Study of a mechanism of growing absolute parametric instability of an inhomogeneous plasma

    Energy Technology Data Exchange (ETDEWEB)

    Archipenko, V.I.; Budnikov, V.N.; Gusakov, E.Z.; Romanchuk, I.A.; Simonchik, L.V. (AN Belorusskoj SSR, Minsk. Inst. Fiziki; AN SSSR, Moscow. Fiziko-Tekhnicheskij Inst.)

    1984-05-25

    The structure of plasma oscillations has been investigated experimentally for the first time in the region of parametric space enhancement. A new mechanism of excitation of the absolute parametric instability is discovered which is realized in the case of a pumping wave of developed space structure propagating in a plasma with configuration other than one-dimensional.

  15. PH-EP Seminar a novel method for measuring the absolute luminosity at the LHC

    CERN Multimedia

    CERN. Geneva; CERN. Geneva

    2005-01-01

    A novel method for determining the absolute luminosity in a colliding-beam experiment at circular accelerators is discussed. It uses vertex reconstruction of beam-gas interaction to determine the beam shapes and beams overlap. This method could be applied (for example) at the main LHC experiments without modification of their detectors.

  16. Absolutely continuous functions of two variables in the sense of Carathéodory

    Czech Academy of Sciences Publication Activity Database

    Šremr, Jiří

    2010-01-01

    Roč. 2010, č. 154 (2010), s. 1-11 ISSN 1072-6691 R&D Projects: GA ČR(CZ) GA201/06/0254 Institutional research plan: CEZ:AV0Z10190503 Keywords : absolutely continuous function * Carathéodory sense * integral representation * derivative of double integral Subject RIV: BA - General Mathematics

  17. An alternative approach to absolute-value test for the parameters of ...

    African Journals Online (AJOL)

    An alternative approach to absolute-value test statistic Mn is developed for conducting tests simultaneously on all the parameters of multiple linear regression models. Under certain null and alternative hypotheses, the new test statistic is shown to have limiting central and noncentral chisquare distributions, respectively.

  18. On the absolute measure of Beta activities; Sobre la medida absoluta de actividades Beta

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-07-01

    A new method for absolute beta counting of solid samples is given. The measurements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  19. On Lacunary p-Absolutely Summable Fuzzy Real-Valued Double Sequence Space

    Directory of Open Access Journals (Sweden)

    Dutta Amar Jyoti

    2014-07-01

    Full Text Available In this article, we introduce the class of p-absolutely summable fuzzy real valued double sequence (2lpFθ We have studied some algebraic properties like solid, symmetric, convergence free, sequence algebra. Further, we establish some relation with the class of p-Cesàro summable double sequences and some other important inclusion results.

  20. Within-day repeatability for absolute quantification of Lawsonia intracellularis bacteria in feces from growing pigs

    DEFF Research Database (Denmark)

    Pedersen, Ken Steen; Pedersen, Klaus H.; Hjulsager, Charlotte Kristiane

    2012-01-01

    Absolute quantification of Lawsonia intracellularis by real-time polymerase chain reaction (PCR) is now possible on a routine basis. Poor repeatability of quantification can result in disease status misclassification of individual pigs when a single fecal sample is obtained. The objective...

  1. Absolute determination of 75Se for international comparison of activity measurements

    International Nuclear Information System (INIS)

    Iglicki, F.A.; Arenillas, P.A.; Furnari, J.C.

    1993-01-01

    An international intercomparison of absolute activity measurements of a solution of Se-75, organized by the Bureau International des Poids et Mesures, France, in 1992, has been carried out. The methodology and results are presented. Source preparation, experimental techniques and measurement system are described. (author). 2 refs

  2. Forest ecosystems functioning of and conducting of forestry in the zones of absolute alienation

    International Nuclear Information System (INIS)

    Yirklyienko, S.P.; Buzun, V.O.; Dmitrenko, O.G.; Turchak, F.M.

    2001-01-01

    The main regularities of forest ecosystems functioning in the zone of absolute alienation were shown. The radio contamination mozaicity of forest ecosystems was underlined. Regularities of 137 Cs accumulation in the wood of the main arboreous species were analyzed. The detailed measures of forestry conducting and forests rehabilitation were proposed

  3. Maple (Computer Algebra System) in Teaching Pre-Calculus: Example of Absolute Value Function

    Science.gov (United States)

    Tuluk, Güler

    2014-01-01

    Modules in Computer Algebra Systems (CAS) make Mathematics interesting and easy to understand. The present study focused on the implementation of the algebraic, tabular (numerical), and graphical approaches used for the construction of the concept of absolute value function in teaching mathematical content knowledge along with Maple 9. The study…

  4. Evidence of Absolute Decoupling from Real World Policy Mixes in Europe

    Directory of Open Access Journals (Sweden)

    Doreen Fedrigo-Fazio

    2016-05-01

    Full Text Available In resource economics, decoupling from environmental impacts is assumed to be beneficial. However, the success of efforts to increase resource productivity should be placed within the context of the earth’s resources and ecosystems as theoretically finite and contingent on a number of threshold values. Thus far relatively few analyses exist of policies which have successfully implemented strategies for decoupling within these limits. Through ex-post evaluation of a number of real world policy mixes from European Union member states, this paper further develops definitions of the concept of decoupling. Beyond absolute (and relative decoupling, “absolute decoupling within limits” is proposed as an appropriate term for defining resource-productivity at any scale which respects the existing real world limits on resources and ecosystems and as such, contributes to meeting sustainability objectives. Policy mixes presented here cover a range of resources such as fish stocks, fertilizers, aggregates and fossil based materials (plastics. Policy mixes demonstrating absolute decoupling and at least one where absolute decoupling within limits has occurred, provide insights on developing resource efficiency policies in Europe and beyond.

  5. Dealing with Absolutes: Religion, the Operational Environment, and the Art of Design

    Science.gov (United States)

    2010-12-01

    environment. Religion as a Presence in the Operational Environment Although many religions have been used to further political, social, or spiritual aims...eschatological and metaphysical aim, religion provides moral and ethical norms for both individual and collective life . In addition, many religions ...most intractable quality . The fact that many religions affirm knowledge of absolute truth makes them much more intractable to interactions that

  6. Determination of the absolute configuration of monosaccharides in complex carbohydrates by capillary G.L.C.

    NARCIS (Netherlands)

    Vliegenthart, J.F.G.; Gerwig, G.J.; Kamerling, J.P.

    1979-01-01

    The absolute configuration of neutral monosaccharides, 2-acetamido-2-deoxy sugars, and uronic acids can be determined by capillary g.l.c. on SE-30 after glycosidation with (-)-2-butanol and protection of the remaining polar groups. The method is illustrated by application to mixtures of the

  7. Effect of HAART on growth parameters and absolute CD4 count ...

    African Journals Online (AJOL)

    The reduction in the proportion of children with moderate malnutrition (WAZ < -2) from time of HAART commencement to nine months after HAART, was by 61.5% in those without severe immune suppression (SIS) and by 50% in those with SIS Conclusion: This study showed that WAZ and absolute CD4 count changes ...

  8. Analysis of Large Flexible Body Deformation in Multibody Systems Using Absolute Coordinates

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Stefan von [Institute of Robotics and Mechatronics, German Aerospace Center (DLR) (Germany)], E-mail: stefan.von.dombrowski@dlr.de

    2002-11-15

    To consider large deformation problems in multibody system simulations a finite element approach, called absolute nodal coordinate.formulation,has been proposed. In this formulation absolute nodal coordinates and their material derivatives are applied to represent both deformation and rigid body motion. The choice of nodal variables allows a fully nonlinear representation of rigid body motion and can provide the exact rigid body inertia in the case of large rotations. The methodology is especially suited for but not limited to modeling of beams, cables and shells in multibody dynamics.This paper summarizes the absolute nodal coordinate formulation for a 3D Euler-Bernoulli beam model, in particular the definition of nodal variables, corresponding generalized elastic and inertia forces and equations of motion. The element stiffness matrix is a nonlinear function of the nodal variables even in the case of linearized strain/displacement relations. Nonlinear strain/displacement relations can be calculated from the global displacements using quadrature formulae.Computational examples are given which demonstrate the capabilities of the applied methodology. Consequences of the choice of shape.functions on the representation of internal forces are discussed. Linearized strain/displacement modeling is compared to the nonlinear approach and significant advantages of the latter, when using the absolute nodal coordinate formulation, are outlined.

  9. The absolute chronology and thermal processing of solids in the solar protoplanetary disk

    DEFF Research Database (Denmark)

    Connelly, James; Bizzarro, Martin; Krot, Alexander N.

    2012-01-01

    Transient heating events that formed calcium-aluminum - rich inclusions (CAIs) and chondrules are fundamental processes in the evolution of the solar protoplanetary disk, but their chronology is not understood. Using U-corrected Pb-Pb dating, we determined absolute ages of individual CAIs...

  10. Absolute standard hydrogen electrode potential measured by reduction of aqueous nanodrops in the gas phase.

    Science.gov (United States)

    Donald, William A; Leib, Ryan D; O'Brien, Jeremy T; Bush, Matthew F; Williams, Evan R

    2008-03-19

    In solution, half-cell potentials are measured relative to those of other half cells, thereby establishing a ladder of thermochemical values that are referenced to the standard hydrogen electrode (SHE), which is arbitrarily assigned a value of exactly 0 V. Although there has been considerable interest in, and efforts toward, establishing an absolute electrochemical half-cell potential in solution, there is no general consensus regarding the best approach to obtain this value. Here, ion-electron recombination energies resulting from electron capture by gas-phase nanodrops containing individual [M(NH3)6]3+, M = Ru, Co, Os, Cr, and Ir, and Cu2+ ions are obtained from the number of water molecules that are lost from the reduced precursors. These experimental data combined with nanodrop solvation energies estimated from Born theory and solution-phase entropies estimated from limited experimental data provide absolute reduction energies for these redox couples in bulk aqueous solution. A key advantage of this approach is that solvent effects well past two solvent shells, that are difficult to model accurately, are included in these experimental measurements. By evaluating these data relative to known solution-phase reduction potentials, an absolute value for the SHE of 4.2 +/- 0.4 V versus a free electron is obtained. Although not achieved here, the uncertainty of this method could potentially be reduced to below 0.1 V, making this an attractive method for establishing an absolute electrochemical scale that bridges solution and gas-phase redox chemistry.

  11. Mapping the absolute electromagnetic field strength of individual field components inside a photonic crystal

    NARCIS (Netherlands)

    Denis, T.; Reijnders, B.; Lee, J.H.H.; Vos, Willem L.; Boller, Klaus J.; van der Slot, Petrus J.M.

    2013-01-01

    We present a method to map the absolute electromagnetic field strength inside photonic crystals. We demonstrate our method by applying it to map the electric field component Ez of a two-dimensional photonic crystal slab at microwave frequencies. The slab is placed between two mirrors to create a

  12. On the relation between the absolute parallelism connection and a GL(4) connection

    International Nuclear Information System (INIS)

    Melek, M.

    1989-12-01

    It is shown that the difference between the absolute parallelism connection and a GL(4) connection can be expressed as a tensor field ω ρμ ν under general coordinate transformations which has the property that the quantity e ν α e β ρ ω ρμ ν behaves as a connection under Lorentz transformations. (author). 5 refs

  13. Long term observation on absolute lymphocyte counts in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Oesterle, S.N.; Norman, J.E. Jr.

    1980-01-01

    Total peripheral blood lymphocytes were evaluated by age and exposure status in the Adult Health Study population during three examination cycles between 1958 and 1972. No radiation effect was observed, but a significant drop in the absolute lymphocyte counts of those aged 70 years and over and a corresponding maximum for persons aged 50 - 59 was observed. (author)

  14. Absolute measurement of the DT primary neutron yield on the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Leeper R.J.

    2013-11-01

    Full Text Available The measurement of the absolute neutron yield produced in inertial confinement fusion target experiments conducted on the National Ignition Facility (NIF is essential in benchmarking progress towards the goal of achieving ignition on this facility. This paper describes three independent diagnostic techniques that have been developed to make accurate and precise DT neutron yield measurements on the NIF.

  15. Improvement of Gaofen-3 Absolute Positioning Accuracy Based on Cross-Calibration

    Directory of Open Access Journals (Sweden)

    Mingjun Deng

    2017-12-01

    Full Text Available The Chinese Gaofen-3 (GF-3 mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to accurately calibrate the geometric calibration parameters of the image (internal delay and azimuth shifts using high-precision ground control data, which are highly dependent on the control data of the calibration field, but it remains costly and labor-intensive to monitor changes in GF-3’s geometric calibration parameters. Based on the positioning consistency constraint of the conjugate points, this study presents a geometric cross-calibration method for the rapid and accurate calibration of GF-3. The proposed method can accurately calibrate geometric calibration parameters without using corner reflectors and high-precision digital elevation models, thus improving absolute positioning accuracy of the GF-3 image. GF-3 images from multiple regions were collected to verify the absolute positioning accuracy after cross-calibration. The results show that this method can achieve a calibration accuracy as high as that achieved by the conventional field calibration method.

  16. Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School

    Science.gov (United States)

    Bogacz, Bogdan F.; Pedziwiatr, Antoni T.

    2014-01-01

    A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…

  17. GeMS MCAO observations of the Galactic globular cluster NGC 2808: the absolute age

    NARCIS (Netherlands)

    Massari, D.; Fiorentino, G.; McConnachie, A.; Bono, G.; Dall'Ora, M.; Ferraro, I.; Iannicola, G.; Stetson, P. B.; Turri, P.; Tolstoy, E.

    2016-01-01

    Context. Globular clusters are the oldest stellar systems in the Milky Way, and they probe the early epoch of the Galaxy formation. However, the uncertainties on their absolute age are still too large to soundly constrain how the Galactic structures have assembled. Aims: The aim of this work is to

  18. Absolute negative conductivity in two-dimensional electron systems under microwave radiation

    OpenAIRE

    Ryzhii, Victor

    2004-01-01

    We overview mechanisms of absolute negative conductivity in two-dimensional electron systems in a magnetic field irradiated with microwaves and provide plausible explanations of the features observed in recent experiments related to the so-called zero-resistance (zero-conductance) states.

  19. VAR Portfolio Optimal: Perbandingan Antara Metode Markowitz dan Mean Absolute Deviation

    Directory of Open Access Journals (Sweden)

    R. Agus Sartono

    2009-05-01

    Full Text Available Portfolio selection method which have been introduced by Harry Markowitz (1952 used variance or deviation standard as a measure of risk. Kanno and Yamazaki (1991 introduced another method and used mean absolute deviation as a measure of risk instead of variance. The Value-at Risk (VaR is a relatively new method to capitalized risk that been used by financial institutions. The aim of this research is compare between mean variance and mean absolute deviation of two portfolios. Next, we attempt to assess the VaR of two portfolios using delta normal method and historical simulation. We use the secondary data from the Jakarta Stock Exchange – LQ45 during 2003. We find that there is a weak-positive correlation between deviation standard and return in both portfolios. The VaR nolmal delta based on mean absolute deviation method eventually is higher than the VaR normal delta based on mean variance method. However, based on the historical simulation the VaR of two methods is statistically insignificant. Thus, the deviation standard is sufficient measures of portfolio risk.Keywords: optimalisasi portofolio, mean-variance, mean-absolute deviation, value-at-risk, metode delta normal, metode simulasi historis

  20. Absolute parametric instability of low-frequency waves in a 2D ...

    Indian Academy of Sciences (India)

    Using the separation method, absolute parametric instability (API) of electrostatic waves in a magnetized pumped warm plasma is investigated. In this case the effect of static strong magnetic field is considered. The problem of strong magnetic field is solved in two-dimensional (2D) nonuniform plane plasma. Equations ...

  1. Active cavity radiometer, type III - An automatic, absolute standard, highly accurate detector

    Science.gov (United States)

    Willson, R. C.

    1971-01-01

    Instrument of simple construction operates without vacuum enclosure over wide pressure range and temperatures from 218 to 398 deg K and defines absolute radiometric scale to within less than 0.5 mW/sq cm. It has potential application to meteorology and climatology and operates on electrical substitution calorimeter principle.

  2. A study on photonic crystal slab waveguide with absolute photonic band gap

    Directory of Open Access Journals (Sweden)

    Katsumasa Satoh

    2018-02-01

    Full Text Available Most of the conventional photonic crystal (PhC slab waveguides have a photonic bandgap (PBG only for one polarization state of two orthogonal polarization states. In this paper, westudy on an absolute PBG that can realize PBG for both polarizations in the same frequency range anddemonstrate that an absolute PBG can be realized in PhC structures proposed here. In the numericalanalysis and design of PhC structures, we employ the two-dimensional finite element method (FEMbased on the effective index method (EIM. First, we propose two-types of PhC structures with anabsolute PBG and show that a steering type PhC is superior to an air-ring type PhC to obtain a widebandabsolute PBG. It is also shown that the optimized steering type PhC has the absolute PBG whosebandwidth of 164 nm at the center wavelength of 1.55 μm. Furthermore, we design PhC waveguidesbased on the obtained PhC structure having an absolute PBG in order to obtain guided modes for bothpolarization states within the same wavelength range. The transmission properties of the designed PhCwaveguides are also investigated and 60 degree bends which are required in compact photonic circuitsare designed. From these results, the possibility to realize compact polarization multiplexing photonicdevices is shown.

  3. Absolute activity determinations on large volume geological samples independent of self-absorption effects

    International Nuclear Information System (INIS)

    Wilson, W.E.

    1980-01-01

    This paper describes a method for measuring the absolute activity of large volume samples by γ-spectroscopy independent of self-absorption effects using Ge detectors. The method yields accurate matrix independent results at the expense of replicative counting of the unknown sample. (orig./HP)

  4. Absolute Quantitation of DNA Methylation of 28 Candidate Genes in Prostate Cancer Using Pyrosequencing

    Directory of Open Access Journals (Sweden)

    Nataڑa Vasiljeviš

    2011-01-01

    Full Text Available Aberrant DNA methylation plays a pivotal role in carcinogenesis and its mapping is likely to provide biomarkers for improved diagnostic and risk assessment in prostate cancer (PCa. We quantified and compared absolute methylation levels among 28 candidate genes in 48 PCa and 29 benign prostate hyperplasia (BPH samples using the pyrosequencing (PSQ method to identify genes with diagnostic and prognostic potential.

  5. Misconceptions of High School Students Related to the Conceptions of Absolutism and Constitutionalism in History Courses

    Science.gov (United States)

    Bal, Mehmet Suat

    2011-01-01

    The goal of this study is to analyze the 10th grade high school students' misconceptions related to the sense of ruling in the Ottoman State during the absolutist and constitutional periods and to investigate the causes of these misconceptions. The data were collected through eight open-ended questions related to the concepts of absolutism and…

  6. Absolutism and Natural Law Argument: William O. Douglas on Freedom of Expression.

    Science.gov (United States)

    Rodgers, Raymond S.

    Noting that United States Supreme Court Justice William O. Douglas has often been characterized as an "absolutist" in terms of First Amendment policy, this paper argues that, in fact, Douglas's policy positions provided for less than absolute freedom to communicate. The paper then reveals, through an anlaysis of 18 of Douglas's opinions,…

  7. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  8. Mapping absolute tissue endogenous fluorophore concentrations with chemometric wide-field fluorescence microscopy

    Science.gov (United States)

    Xu, Zhang; Reilley, Michael; Li, Run; Xu, Min

    2017-06-01

    We report chemometric wide-field fluorescence microscopy for imaging the spatial distribution and concentration of endogenous fluorophores in thin tissue sections. Nonnegative factorization aided by spatial diversity is used to learn both the spectral signature and the spatial distribution of endogenous fluorophores from microscopic fluorescence color images obtained under broadband excitation and detection. The absolute concentration map of individual fluorophores is derived by comparing the fluorescence from "pure" fluorophores under the identical imaging condition following the identification of the fluorescence species by its spectral signature. This method is then demonstrated by characterizing the concentration map of endogenous fluorophores (including tryptophan, elastin, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide) for lung tissue specimens. The absolute concentrations of these fluorophores are all found to decrease significantly from normal, perilesional, to cancerous (squamous cell carcinoma) tissue. Discriminating tissue types using the absolute fluorophore concentration is found to be significantly more accurate than that achievable with the relative fluorescence strength. Quantification of fluorophores in terms of the absolute concentration map is also advantageous in eliminating the uncertainties due to system responses or measurement details, yielding more biologically relevant data, and simplifying the assessment of competing imaging approaches.

  9. Exact theory of optical tweezers and its application to absolute calibration

    DEFF Research Database (Denmark)

    Dutra, Rafael de Sousa; Viana, Nathan B.; Maia Neto, Paulo A.

    2017-01-01

    Optical tweezers have become a powerful tool for basic and applied research in cell biology. Here, we describe an experimentally verified theory for the trapping forces generated by optical tweezers based on first principles that allows absolute calibration. For pedagogical reasons, the steps tha...

  10. The gender- and age-specific 10-year and lifetime absolute fracture risk in Tromso, Norway

    International Nuclear Information System (INIS)

    Ahmed, Luai A.; Schirmer, Henrik; Bjornerem, Ashild; Emaus, Nina; Jorgensen, Lone; Stormer, Jan; Joakimsen, Ragnar M.

    2009-01-01

    Aim of this study is to estimate the gender- and age-specific 10-year and lifetime absolute risks of non-vertebral and osteoporotic (included hip, distal forearm and proximal humerus) fractures in a large cohort of men and women. This is a population-based 10 years follow-up study of 26,891 subjects aged 25 years and older in Tromso, Norway. All non-vertebral fractures were registered from 1995 throughout 2004 by computerized search in radiographic archives. Absolute risks were estimated by life-table method taking into account the competing risk of death. The absolute fracture risk at each year of age was estimated for the next 10 years (10-year risk) or up to the age of 90 years (lifetime risk). The estimated 10-year absolute risk of all non-vertebral fracture was higher in men than women before but not after the age of 45 years. The 10-year absolute risk for non-vertebral and osteoporotic fractures was over 10%, respectively, in men over 65 and 70 years and in women over 45 and 50 years of age. The 10-year absolute risks of hip fractures at the age of 65 and 80 years were 4.2 and 18.6% in men, and 9.0 and 24.0% in women, respectively. The risk estimates for distal forearm and proximal humerus fractures were under 5% in men and 13% in women. The estimated lifetime risks for all fracture locations were higher in women than men at all ages. At the age of 50 years, the risks were 38.1 and 24.8% in men and 67.4 and 55.0% in women for all non-vertebral and osteoporotic fractures, respectively. The estimated gender- and age-specific 10-year and lifetime absolute fracture risk were higher in Tromso than in other populations. The high lifetime fracture risk reflects the increased burden of fractures in this cohort

  11. Absolute and relative temporal order memory for performed activities following stroke.

    Science.gov (United States)

    Schoo, Linda A; van Zandvoort, Martine J E; Reijmer, Yael D; Biessels, Geert Jan; Kappelle, L Jaap; Postma, Albert

    2014-01-01

    Reconstructing the temporal order of events is a crucial part of episodic memory. The temporal dimension, however, is often discarded in clinical settings, and measurements of true temporal aspects of episodic memory are scarce. The present study assessed temporal memory in stroke patients and in age- and education-matched healthy controls. Both groups underwent a standardized neuropsychological examination. We asked participants afterwards to reconstruct the order of tests they had performed, measured in absolute temporal order (event placed on correct moment in sequence) and relative temporal order (event placed correctly relative to directly preceding and following events). The aim of the study was to examine how serial-position curve effects (measuring absolute temporal order anchored in exact time) and how relative temporal order memory (anchored to other events) may differ in a group of cerebral stroke patients. Another aim was to link temporal order memory deficits with established neuropsychological measures of cognitive functioning. Although item identification was comparable in both groups, absolute temporal order memory was impaired in patients: A total of 43% of the patients lacked the expected primacy and recency effects (serial position effect). In addition, relative temporal order memory was affected in this group as well, F(1, 70) = 4.08, p < .05; 25% of the patients were impaired in reconstructing the relative temporal order (p = .019, Fisher's Exact Test). Both absolute and relative temporal order memory performance related to the domains of executive functioning and memory. Our results suggest that it is important to test both absolute and relative temporal order memory, especially because these types of memory depend on different anchors, either on time or on adjacent events.

  12. The Path to an Up-to-date Absolute Gravity Reference System

    Science.gov (United States)

    Wilmes, H.; Falk, R.; Wziontek, H.

    2014-12-01

    The determination of precise gravity field parameters is of great importance in a period in which earth sciences are achieving the necessary accuracy to monitor and document global change processes. This is the reason why experts from geodesy and metrology joined in a successful cooperation to make absolute gravity observations traceable to SI quantities, to improve the metrological kilogram definition and to monitor mass movements and smallest height changes for geodetic and geophysical applications. How can we determine such a gravity reference system and secure it over multiple decades? Precise knowledge of the gravity acceleration and definition of standards, models and corrections are an important prerequisite to the definition of the gravity system. Over more than three decades, the absolute gravity community cooperated successfully to obtain the gravity reference in comparisons at intervals of 4 years and to certify metrological equivalence between National Metrology Institutes. With increasing resolution of the absolute gravimeter sensors and new measurement principles it becomes obvious that such comparisons are not sufficient for all applications. Mainly for geodetic purposes it is necessary to sub-divide comparison intervals and maintain a connected network of gravity reference sites where compared absolute gravimeters operate together with superconducting gravimeters to derive a continuous gravity reference function. By means of this distributed monitoring of the gravity reference it will also be possible to relate observations of earlier absolute gravimeters to the present-day and to future instruments. It will be possible to include new sensors like atom interferometers and in future to relate the results of precise optical clocks. With co-located space geodetic sensors like GNSS, SLR and VLBI, these reference sites fulfill the conditions of a geodetic fundamental station as a component of IAG's Global Geodetic Observing System.

  13. Is the "Heart Age" Concept Helpful or Harmful Compared to Absolute Cardiovascular Disease Risk? An Experimental Study.

    Science.gov (United States)

    Bonner, Carissa; Jansen, Jesse; Newell, Ben R; Irwig, Les; Teixeira-Pinto, Armando; Glasziou, Paul; Doust, Jenny; McKinn, Shannon; McCaffery, Kirsten

    2015-11-01

    Cardiovascular disease (CVD) prevention guidelines are generally based on the absolute risk of a CVD event, but there is increasing interest in using 'heart age' to motivate lifestyle change when absolute risk is low. Previous studies have not compared heart age to 5-year absolute risk, or investigated the impact of younger heart age, graphical format, and numeracy. Compare heart age versus 5-year absolute risk on psychological and behavioral outcomes. 2 (heart age, absolute risk) × 3 (text only, bar graph, line graph) experiment. Online. 570 Australians aged 45-64 years, not taking CVD-related medication. CVD risk assessment. Intention to change lifestyle, recall, risk perception, emotional response, perceived credibility, and lifestyle behaviors after 2 weeks. Most participants had lifestyle risk factors (95%) but low 5-year absolute risk (94%). Heart age did not improve lifestyle intentions and behaviors compared to absolute risk, was more often interpreted as a higher-risk category by low-risk participants (47% vs 23%), and decreased perceived credibility and positive emotional response. Overall, correct recall dropped from 65% to 24% after 2 weeks, with heart age recalled better than absolute risk at 2 weeks (32% vs 16%). These results were found across younger and older heart age results, graphical format, and numeracy. Communicating CVD risk in a consultation rather than online may produce different results. There is no evidence that heart age motivates lifestyle change more than 5-year absolute risk in individuals with low CVD risk. Five-year absolute risk may be a better way to explain CVD risk, because it is more credible, does not inflate risk perception, and is consistent with clinical guidelines that base lifestyle and medication recommendations on absolute risk. © The Author(s) 2015.

  14. Absolute magnitude estimation and relative judgement approaches to subjective workload assessment

    Science.gov (United States)

    Vidulich, Michael A.; Tsang, Pamela S.

    1987-01-01

    Two rating scale techniques employing an absolute magnitude estimation method, were compared to a relative judgment method for assessing subjective workload. One of the absolute estimation techniques used was an unidimensional overall workload scale and the other was the multidimensional NASA-Task Load Index technique. Thomas Saaty's Analytic Hierarchy Process was the unidimensional relative judgment method used. These techniques were used to assess the subjective workload of various single- and dual-tracking conditions. The validity of the techniques was defined as their ability to detect the same phenomena observed in the tracking performance. Reliability was assessed by calculating test-retest correlations. Within the context of the experiment, the Saaty Analytic Hierarchy Process was found to be superior in validity and reliability. These findings suggest that the relative judgment method would be an effective addition to the currently available subjective workload assessment techniques.

  15. Pixel-based absolute surface metrology by three flat test with shifted and rotated maps

    Science.gov (United States)

    Zhai, Dede; Chen, Shanyong; Xue, Shuai; Yin, Ziqiang

    2018-03-01

    In traditional three flat test, it only provides the absolute profile along one surface diameter. In this paper, an absolute testing algorithm based on shift-rotation with three flat test has been proposed to reconstruct two-dimensional surface exactly. Pitch and yaw error during shift procedure is analyzed and compensated in our method. Compared with multi-rotation method proposed before, it only needs a 90° rotation and a shift, which is easy to carry out especially in condition of large size surface. It allows pixel level spatial resolution to be achieved without interpolation or assumption to the test surface. In addition, numerical simulations and optical tests are implemented and show the high accuracy recovery capability of the proposed method.

  16. High-precision absolute distance measurement using dual-laser frequency scanned interferometry under realistic conditions

    International Nuclear Information System (INIS)

    Yang, H.-J.; Nyberg, Sven; Riles, Keith

    2007-01-01

    In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. Dual lasers with oppositely scanning directions, combined with a multi-distance-measurement technique previously reported, were used to cancel drift errors and to suppress vibration effects and interference fringe uncertainties. Under realistic conditions, a precision about 0.2μm was achieved for a distance of 0.41m. With a precision that exceeds requirements, the frequency scanned interferometry is a promising high-precision optical alignment technique for International Linear Collider silicon tracker detector

  17. ACRE: Absolute concentration robustness exploration in module-based combinatorial networks

    KAUST Repository

    Kuwahara, Hiroyuki

    2017-03-01

    To engineer cells for industrial-scale application, a deep understanding of how to design molecular control mechanisms to tightly maintain functional stability under various fluctuations is crucial. Absolute concentration robustness (ACR) is a category of robustness in reaction network models in which the steady-state concentration of a molecular species is guaranteed to be invariant even with perturbations in the other molecular species in the network. Here, we introduce a software tool, absolute concentration robustness explorer (ACRE), which efficiently explores combinatorial biochemical networks for the ACR property. ACRE has a user-friendly interface, and it can facilitate efficient analysis of key structural features that guarantee the presence and the absence of the ACR property from combinatorial networks. Such analysis is expected to be useful in synthetic biology as it can increase our understanding of how to design molecular mechanisms to tightly control the concentration of molecular species. ACRE is freely available at https://github.com/ramzan1990/ACRE.

  18. Pure Absolutely Continuous Spectrum for Random Operators on $l^2(Z^d)$ at Low Disorder

    CERN Document Server

    Grinshpun, V

    2006-01-01

    Absence of singular continuous component, with probability one, in the spectra of random perturbations of multidimensional finite-difference Hamiltonians, is for the first time rigorously established under certain conditions ensuring either absence of point component, or absence of absolutely continuous component in the corresponding regions of spectra. The main technical tool involved is the rank-one perturbation theory of singular spectra. The respective new result (the non-mixing property) is applied to establish existence and bounds of the (non-empty) pure absolutely continuous component in the spectrum of the Anderson model with bounded random potential in dimension d=2 at low disorder (similar proof holds for d>4). The new result implies, via the trace-class perturbation analysis, Anderson model with the unbounded random potential having only pure point spectrum (complete system of localized wave-functions) with probability one in arbitrary dimension. The basic idea is to establish absence of the mixed,...

  19. Absolute near-infrared refractometry with a calibrated tilted fiber Bragg grating.

    Science.gov (United States)

    Zhou, Wenjun; Mandia, David J; Barry, Seán T; Albert, Jacques

    2015-04-15

    The absolute refractive indices (RIs) of water and other liquids are determined with an uncertainty of ±0.001 at near-infrared wavelengths by using the tilted fiber Bragg grating (TFBG) cladding mode resonances of a standard single-mode fiber to measure the critical angle for total internal reflection at the interface between the fiber and its surroundings. The necessary condition to obtain absolute RIs (instead of measuring RI changes) is a thorough characterization of the dispersion of the core mode effective index of the TFBG across the full range of its cladding mode resonance spectrum. This technique is shown to be competitive with the best available measurements of the RIs of water and NaCl solutions at wavelengths in the vicinity of 1550 nm.

  20. The CLARA/NORSAT-1 solar absolute radiometer: instrument design, characterization and calibration

    Science.gov (United States)

    Walter, Benjamin; Levesque, Pierre-Luc; Kopp, Greg; Andersen, Bo; Beck, Ivo; Finsterle, Wolfgang; Gyo, Manfred; Heuerman, Karl; Koller, Silvio; Mingard, Nathan; Remesal Oliva, Alberto; Pfiffner, Daniel; Soder, Ricco; Spescha, Marcel; Suter, Markus; Schmutz, Werner

    2017-10-01

    The compact lightweight absolute radiometer (CLARA) experiment aims at measuring the total solar irradiance (TSI) in space and is scheduled to fly on the Norwegian NORSAT-1 micro satellite. The CLARA experiment will contribute to the long term monitoring of the TSI variability to support the analysis of potential long term trends in the Sun’s variability. CLARA is traceable to the National Institute of Standards and Technology radiometric scale and will provide further evidence for the TSI value on an absolute scale. In this paper we present the design, characterization, and calibration details of the CLARA instrument. The combined measurement uncertainty for the calibrated SI-traceable CLARA flight instrument is 567-912 ppm (k  =  1) depending on the measuring channel.

  1. An experimental study on renal artery embolization using absolute ethanol, with special emphasis on infusion rate

    International Nuclear Information System (INIS)

    Han, Joon Koo; Lee, Young Seok; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung

    1984-01-01

    Transcatheter embolization using absolute ethanol is a widely used technic in interventional radiology. But its mechanism of action and embolization effect on various infusion speed are poorly understood. Authors performed an experimental study in rabbits to document the effect of absolute ethanol on various infusion rate. The results are as follows: 1. In high speed infusion group (>0.1 ml/sec. n=13), 11 case showed peripheral obstruction and 2 cases showed central obstruction. 2. In low speed infusion group (<0.1 ml/sec. n=12), 4 cases showed peripheral obstruction and 8 cases showed central obstruction (p< 0.02). 3. On follow-up angiography performed 4 weeks later (n=8), no demonstrable significant differences are found between two groups.

  2. Absolute total and partial dissociative cross sections of pyrimidine at electron and proton intermediate impact velocities

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Wania, E-mail: wania@if.ufrj.br; Luna, Hugo; Sigaud, Lucas; Montenegro, Eduardo C. [Instituto de Física, Universidade Federal do Rio de Janeiro, PO 68528, 21941-972 Rio de Janeiro, RJ (Brazil); Tavares, Andre C. [Departamento de Física, Pontificia Universidade Católica do Rio de Janeiro, PO 38071, Rua Marquês de São Vicente 225, 22453-900 Rio de Janeiro, RJ (Brazil)

    2014-02-14

    Absolute total non-dissociative and partial dissociative cross sections of pyrimidine were measured for electron impact energies ranging from 70 to 400 eV and for proton impact energies from 125 up to 2500 keV. MOs ionization induced by coulomb interaction were studied by measuring both ionization and partial dissociative cross sections through time of flight mass spectrometry and by obtaining the branching ratios for fragment formation via a model calculation based on the Born approximation. The partial yields and the absolute cross sections measured as a function of the energy combined with the model calculation proved to be a useful tool to determine the vacancy population of the valence MOs from which several sets of fragment ions are produced. It was also a key point to distinguish the dissociation regimes induced by both particles. A comparison with previous experimental results is also presented.

  3. Relative and absolute level populations in beam-foil--excited neutral helium

    International Nuclear Information System (INIS)

    Davidson, J.

    1975-01-01

    Relative and absolute populations of 19 levels in beam-foil--excited neutral helium at 0.275 MeV have been measured. The singlet angular-momentum sequences show dependences on principal quantum number consistent with n -3 , but the triplet sequences do not. Singlet and triplet angular-momentum sequences show similar dependences on level excitation energy. Excitation functions for six representative levels were measured in the range 0.160 to 0.500 MeV. The absolute level populations increase with energy, whereas the neutral fraction of the beam decreases with energy. Further, the P angular-momentum levels are found to be overpopulated with respect to the S and D levels. The overpopulation decreases with increasing principal quantum number

  4. Relative and absolute level populations in beam-foil-excited neutral helium

    Science.gov (United States)

    Davidson, J.

    1975-01-01

    Relative and absolute populations of 19 levels in beam-foil-excited neutral helium at 0.275 MeV have been measured. The singlet angular-momentum sequences show dependences on principal quantum number consistent with n to the -3rd power, but the triplet sequences do not. Singlet and triplet angular-momentum sequences show similar dependences on level excitation energy. Excitation functions for six representative levels were measured in the range from 0.160 to 0.500 MeV. The absolute level populations increase with energy, whereas the neutral fraction of the beam decreases with energy. Further, the P angular-momentum levels are found to be overpopulated with respect to the S and D levels. The overpopulation decreases with increasing principal quantum number.

  5. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  6. The Absolute, Relative and Multi-Wavelength Calibration of the Pierre Auger Observatory Fluorescence Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Knapik, R.; Bauleo, P.; Becker, B.R.; Brack, J.; Caruso, R.; Fratte, C.Delle; Dorofeev, A.; Harton, J.; Insolia, A.; Matthews, J.A.J.; Menshikov, A.

    2007-08-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single measurement. The relative response has been measured at wavelengths of 320, 337, 355, 380 and 405 nm, defining a spectral response curve which has been normalized to the absolute calibration. Before and after each night of data taking a relative calibration of the phototubes is performed. This relative calibration is used to track both short and long term changes in the detector's response. A cross check of the calibration in some phototubes is performed using an independent laser technique. Overall uncertainties, current results and future plans are discussed.

  7. Spectrophotometry of Wolf-Rayet stars - Intrinsic colors and absolute magnitudes

    Science.gov (United States)

    Torres-Dodgen, Ana V.; Massey, Philip

    1988-01-01

    Absolute spectrophotometry of about 10-A resolution in the range 3400-7300 A have been obtained for southern Wolf-Rayet stars, and line-free magnitudes and colors have been constructed. The emission-line contamination in the narrow-band ubvr systems of Westerlund (1966) and Smith (1968) is shown to be small for most WN stars, but to be quite significant for WC stars. It is suggested that the more severe differences in intrinsic color from star to star of the same spectral subtype noted at shorter wavelengths are due to differences in atmospheric extent. True continuum absolute visual magnitudes and intrinsic colors are obtained for the LMC WR stars. The most visually luminous WN6-WN7 stars are found to be located in the core of the 30 Doradus region.

  8. The status of the Canadian primary heavy water standard and the assignment of the absolute value

    International Nuclear Information System (INIS)

    Thurston, W.M.; James, M.W.D.

    1984-08-01

    The D 2 O concentration of the Canadian Primary Standard has been reviewed and an accurate redetermination of the deuterium content has been made using the absolute method recently developed at CRNL. A new value of 99.9720 +- 0.0006 wt percent has been determined and its use is recommended. On and after November 1, 1984 the assigned concentration values of secondary standards based on the Canadian Primary Standard should be changed correspondingly as should the value for heavy water in reactors and inventory and the associated reactor grade specifications. The new value of the Canadian Primary Standard is in good agreement with results from international intercomparisons, is directly established with absolute determinations, and is easily verifiable in the future. An appendix describes a container which facilitates intercomparisons and long term storage of standards and their handling in interlaboratory comparisons

  9. Determination of collagen fibril size via absolute measurements of second-harmonic generation signals

    Science.gov (United States)

    Bancelin, Stéphane; Aimé, Carole; Gusachenko, Ivan; Kowalczuk, Laura; Latour, Gaël; Coradin, Thibaud; Schanne-Klein, Marie-Claire

    2014-09-01

    The quantification of collagen fibril size is a major issue for the investigation of pathological disorders associated with structural defects of the extracellular matrix. Second-harmonic generation microscopy is a powerful technique to characterize the macromolecular organization of collagen in unstained biological tissues. Nevertheless, due to the complex coherent building of this nonlinear optical signal, it has never been used to measure fibril diameter so far. Here we report absolute measurements of second-harmonic signals from isolated fibrils down to 30 nm diameter, via implementation of correlative second-harmonic-electron microscopy. Moreover, using analytical and numerical calculations, we demonstrate that the high sensitivity of this technique originates from the parallel alignment of collagen triple helices within fibrils and the subsequent constructive interferences of second-harmonic radiations. Finally, we use these absolute measurements as a calibration for ex vivo quantification of fibril diameter in the Descemet’s membrane of a diabetic rat cornea.

  10. Measuring Absolute RNA Copy Numbers at High Temporal Resolution Reveals Transcriptome Kinetics in Development

    Directory of Open Access Journals (Sweden)

    Nick D.L. Owens

    2016-01-01

    Full Text Available Transcript regulation is essential for cell function, and misregulation can lead to disease. Despite technologies to survey the transcriptome, we lack a comprehensive understanding of transcript kinetics, which limits quantitative biology. This is an acute challenge in embryonic development, where rapid changes in gene expression dictate cell fate decisions. By ultra-high-frequency sampling of Xenopus embryos and absolute normalization of sequence reads, we present smooth gene expression trajectories in absolute transcript numbers. During a developmental period approximating the first 8 weeks of human gestation, transcript kinetics vary by eight orders of magnitude. Ordering genes by expression dynamics, we find that “temporal synexpression” predicts common gene function. Remarkably, a single parameter, the characteristic timescale, can classify transcript kinetics globally and distinguish genes regulating development from those involved in cellular metabolism. Overall, our analysis provides unprecedented insight into the reorganization of maternal and embryonic transcripts and redefines our ability to perform quantitative biology.

  11. Gravity and absolute space. The works of Niels Bjern (1865-1909)

    International Nuclear Information System (INIS)

    Burlankov, Dmitrii E

    2004-01-01

    Nearly 20 years before Einstein, Niels Bjern developed a theory of gravity based on what is today known as the equivalence principle - but naturally without invoking the ideas of the special relativity theory. Bjern predicted almost all the effects considered to be tests for general relativity, his calculation formulas for the effects being identical to those of general relativity. An advocate of the absolute space concept, Bjern described the gravitational field in terms of the field of absolute velocities of an inertial space. He only used the ideas of general relativity to describe the precession of the perihelion of Mercury. The reason why Bjern's predictions and those of general relativity are identical is discussed. (from the history of physics)

  12. Absolute Pitch in Oral Transmission of Folk Tunes as Constrained Random Walks

    Directory of Open Access Journals (Sweden)

    Klaus Frieler

    2015-12-01

    Full Text Available In this commentary, I would like to add a few of our own, still unpublished, empirical observations concerning the possible role of absolute pitch memory (APM in the oral transmission of folksongs. This empirical data poses some questions about the likelihood of the observed inter-recording tonic pitch consistency of Olthof, Janssen & Honing (2015 and how these observations could come about. Based on simulations of absolute pitch class of tonics during oral transmission of folk songs, I argue that the interplay of melodic range and vocal range might actually be the main reason for the observed non-uniformity, in contrast to the conclusions presented in Olthof et al. (2015. However, this does not invalidate the therein-presented evidence, but makes the case more puzzling, consequently calling for more empirical research on the interaction of melodic and vocal range and latent APM as well as for more detailed modeling of oral transmission of folk songs.

  13. Strongmen sport is associated with larger absolute heart size and impaired cardiac relaxation.

    Science.gov (United States)

    Venckunas, Tomas; Vasiliauskas, Donatas; Marcinkeviciene, Jolanta E; Grizas, Vytautas; Stasiulis, Arvydas; Malkova, Dalia

    2011-10-01

    This study was carried out to compare cardiac structure and function and blood lipids among Strongmen, sedentary controls, and marathoners. Echocardiography was performed, and endothelial function, blood lipids and maximal oxygen uptake were measured in 27 Caucasian adult men (8 Strongmen, 10 marathoners, 9 controls). Absolute cardiac size parameters such as left ventricular (LV) diameter and wall thickness of Strongmen were higher (p 0.05). Maximal oxygen uptake of Strongmen was lower than in controls (p Global diastolic LV function of Strongmen was impaired in comparison to controls (p sport is associated with higher absolute but not relative cardiac size parameters, impaired myocardial relaxation, and low cardiorespiratory fitness. Therefore, Strongmen may demand greater attention as an extreme group of athletes with regard to cardiovascular risk.

  14. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  15. An Overview of the Use of Absolute Dating Techniques in Ancient Construction Materials

    Directory of Open Access Journals (Sweden)

    Jorge Sanjurjo-Sánchez

    2016-04-01

    Full Text Available The reconstruction of the chronology of historical buildings is a tricky issue, as usually there are not historical documents that allow the assessment of construction phases, and some materials are hardly reliable for the use of dating techniques (e.g., stone. However, in the last two decades, important advances on the use of absolute dating methods on building materials have increased the possibilities of reconstructing building chronologies, although some advances are still scarcely known among archaeologists and architects. Recent studies performed on several kinds of mortars, fired bricks, mud-bricks, and even stone surfaces have shown that it is possible to date them. Both radiocarbon and luminescence dating have been the most frequently used techniques but others such as archaeomagnetism can also be used in some cases. This paper intends to give an overview of the recent achievements on the use of absolute dating techniques for building materials.

  16. Simplified absolute phase retrieval of dual-frequency fringe patterns in fringe projection profilometry

    Science.gov (United States)

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-04-01

    In fringe projection profilometry, a simplified method is proposed to recover absolute phase maps of two-frequency fringe patterns by using a unique mapping rule. The mapping rule is designed from the rounded phase values to the fringe order of each pixel. Absolute phase can be recovered by the fringe order maps. Unlike the existing techniques, where the lowest frequency of dual- or multiple-frequency fringe patterns must be single, the presented method breaks the limitation and simplifies the procedure of phase unwrapping. Additionally, due to many issues including ambient light, shadow, sharp edges, step height boundaries and surface reflectivity variations, a novel framework of automatically identifying and removing invalid phase values is also proposed. Simulations and experiments have been carried out to validate the performances of the proposed method.

  17. Development of combined absolute and activated charcoal filters and glove box activated charcoal filter

    International Nuclear Information System (INIS)

    Khan, A.A.; Ramarathinam, K.; Deshingkar, D.S.; Kishore, A.G.

    1975-01-01

    Because of low maximum permissible concentration in air, airborne radioiodine must be removed from exhaust of nuclear facilities. Activated charcoal filters for glove-boxes and combined absolute and activated charcoal filters are currently being imported. In this work, activated charcoal filters of various types were developed using original as well as impregnated indigenous activated charcoals. These filters were evaluated for their iodine and methyl iodide removal efficiencies and pressure drop characteristics. The filters developed showed 99.9 + % removal efficiency both for iodine and methyl iodide. The pressure drop of the combined absolute and activated charcoal filters was even less than that of imported filters of this type. These filters can effectively substitute imported filters. (author)

  18. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lotze, Stephan, E-mail: lotze@amolf.nl; Versluis, Jan [FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam (Netherlands); Olijve, Luuk L. C.; Schijndel, Luuk van; Milroy, Lech G.; Voets, Ilja K. [Laboratory of Macromolecular and Organic Chemistry, Department of Chemical Engineering and Chemistry, and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Bakker, Huib J., E-mail: bakker@amolf.nl [FOM Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands)

    2015-11-28

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces.

  19. Quantifying discipline practices using absolute versus relative frequencies: clinical and research implications for child welfare.

    Science.gov (United States)

    Lindhiem, Oliver; Shaffer, Anne; Kolko, David J

    2014-01-01

    In the parent intervention outcome literatures, discipline practices are generally quantified as absolute frequencies or, less commonly, as relative frequencies. These differences in methodology warrant direct comparison as they have critical implications for study results and conclusions among treatments targeted at reducing parental aggression and harsh discipline. In this study, we directly compared the absolute frequency method and the relative frequency method for quantifying physically aggressive, psychologically aggressive, and nonaggressive discipline practices. Longitudinal data over a 3-year period came from an existing data set of a clinical trial examining the effectiveness of a psychosocial treatment in reducing parental physical and psychological aggression and improving child behavior (N = 139). Discipline practices (aggressive and nonaggressive) were assessed using the Conflict Tactics Scale. The two methods yielded different patterns of results, particularly for nonaggressive discipline strategies. We suggest that each method makes its own unique contribution to a more complete understanding of the association between parental aggression and intervention effects.

  20. Experimental assessment of the speed of light perturbation in free-fall absolute gravimeters

    CERN Document Server

    Baumann, H; Blas, D.; Sibiryakov, S.; Eichenberger, A.; Klingelé, E.E.

    2015-01-01

    Precision absolute gravity measurements are growing in importance, especially in the context of the new definition of the kilogram. For the case of free-fall absolute gravimeters with a Michelson-type interferometer tracking the position of a free falling body, one of the effects that needs to be taken into account is the speed of light perturbation due to the finite speed of propagation of light. This effect has been extensively discussed in the past, and there is at present a disagreement between different studies. In this work, we present the analysis of new data and confirm the result expected from the theoretical analysis applied nowadays in free-fall gravimeters. We also review the standard derivations of this effect (by using phase shift or Doppler effect arguments) and show their equivalence.

  1. Entrenched geographical and socioeconomic disparities in child mortality: trends in absolute and relative inequalities in Cambodia.

    Directory of Open Access Journals (Sweden)

    Eliana Jimenez-Soto

    Full Text Available BACKGROUND: Cambodia has made considerable improvements in mortality rates for children under the age of five and neonates. These improvements may, however, mask considerable disparities between subnational populations. In this paper, we examine the extent of the country's child mortality inequalities. METHODS: Mortality rates for children under-five and neonates were directly estimated using the 2000, 2005 and 2010 waves of the Cambodian Demographic Health Survey. Disparities were measured on both absolute and relative scales using rate differences and ratios, and where applicable, slope and relative indices of inequality by levels of rural/urban location, regions and household wealth. FINDINGS: Since 2000, considerable reductions in under-five and to a lesser extent in neonatal mortality rates have been observed. This mortality decline has, however, been accompanied by an increase in relative inequality in both rates of child mortality for geography-related stratifying markers. For absolute inequality amongst regions, most trends are increasing, particularly for neonatal mortality, but are not statistically significant. The only exception to this general pattern is the statistically significant positive trend in absolute inequality for under-five mortality in the Coastal region. For wealth, some evidence for increases in both relative and absolute inequality for neonates is observed. CONCLUSION: Despite considerable gains in reducing under-five and neonatal mortality at a national level, entrenched and increased geographical and wealth-based inequality in mortality, at least on a relative scale, remain. As expected, national progress seems to be associated with the period of political and macroeconomic stability that started in the early 2000s. However, issues of quality of care and potential non-inclusive economic growth might explain remaining disparities, particularly across wealth and geography markers. A focus on further addressing key

  2. Estimating Absolute and Relative Physical Activity Intensity Across Age via Accelerometry in Adults

    OpenAIRE

    Miller, Nora E.; Strath, Scott J.; Swartz, Ann M.; Cashin, Susan E.

    2010-01-01

    This study examined the predictive validity of accelerometers (ACC) to estimate physical activity intensity (PAI) across age and differences in intensity predictions when expressed in relative and absolute PAI terms. Ninety adults categorized into 3 age groups (20–29, 40–49, and 60–69 yr) completed a treadmill calibration study with simultaneous ACC (7164 Actigraph) and oxygen-consumption assessment. Results revealed strong linear relations between ACC output and measured PAI (R2 = .62–.89) a...

  3. Absolute value optimization to estimate phase properties of stochastic time series

    Science.gov (United States)

    Scargle, J. D.

    1977-01-01

    Most existing deconvolution techniques are incapable of determining phase properties of wavelets from time series data; to assure a unique solution, minimum phase is usually assumed. It is demonstrated, for moving average processes of order one, that deconvolution filtering using the absolute value norm provides an estimate of the wavelet shape that has the correct phase character when the random driving process is nonnormal. Numerical tests show that this result probably applies to more general processes.

  4. Lingual orthodontic treatment and absolute anchorage to correct an impacted maxillary canine in an adult.

    Science.gov (United States)

    Chaushu, Stella; Becker, Adrian; Chaushu, Gavriel

    2008-12-01

    There are 2 major drawbacks to the classic orthodontic-surgical approach for resolution of impacted teeth in adults: appearance and duration of treatment. This case report illustrates the lingual orthodontic treatment of an adult with an impacted maxillary canine; absolute anchorage was achieved with a miniscrew placed in the palate. The combination of invisible appliances and a nondental anchorage system is particularly useful in adults and should make treatment available to more patients.

  5. Absolute standardization of 121Te by gamma spectrometry using the peak-sum method

    International Nuclear Information System (INIS)

    Araujo, Miriam Taina Ferreira de

    2015-01-01

    This work has as main objective to develop a methodology for identification and quantification of impurities in the production process of the radiopharmaceutical [ 123 I]Nal. As a specific goal we mention the process of absolute standardization of 121 Te. The determination of some nuclear parameters associated with the decay is the step of secondary endpoints where data obtained will be compared with the existing literature

  6. Absolute radiometric calibration of Landsat using a pseudo invariant calibration site

    Science.gov (United States)

    Helder, D.; Thome, K.J.; Mishra, N.; Chander, G.; Xiong, Xiaoxiong; Angal, A.; Choi, Tae-young

    2013-01-01

    Pseudo invariant calibration sites (PICS) have been used for on-orbit radiometric trending of optical satellite systems for more than 15 years. This approach to vicarious calibration has demonstrated a high degree of reliability and repeatability at the level of 1-3% depending on the site, spectral channel, and imaging geometries. A variety of sensors have used this approach for trending because it is broadly applicable and easy to implement. Models to describe the surface reflectance properties, as well as the intervening atmosphere have also been developed to improve the precision of the method. However, one limiting factor of using PICS is that an absolute calibration capability has not yet been fully developed. Because of this, PICS are primarily limited to providing only long term trending information for individual sensors or cross-calibration opportunities between two sensors. This paper builds an argument that PICS can be used more extensively for absolute calibration. To illustrate this, a simple empirical model is developed for the well-known Libya 4 PICS based on observations by Terra MODIS and EO-1 Hyperion. The model is validated by comparing model predicted top-of-atmosphere reflectance values to actual measurements made by the Landsat ETM+ sensor reflective bands. Following this, an outline is presented to develop a more comprehensive and accurate PICS absolute calibration model that can be Système international d'unités (SI) traceable. These initial concepts suggest that absolute calibration using PICS is possible on a broad scale and can lead to improved on-orbit calibration capabilities for optical satellite sensors.

  7. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  8. Absolute calibration of photon-number-resolving detectors with an analog output using twin beams

    Science.gov (United States)

    Peřina, Jan; Haderka, Ondřej; Allevi, Alessia; Bondani, Maria

    2014-01-01

    A method for absolute calibration of a photon-number resolving detector producing analog signals as the output is developed using a twin beam. The method gives both analog-to-digital conversion parameters and quantum detection efficiency for the photon fields. Characteristics of the used twin beam are also obtained. A simplified variant of the method applicable to fields with high signal to noise ratios and suitable for more intense twin beams is suggested.

  9. Determining the Absolute Configuration of Two Marine Compounds Using Vibrational Chiroptical Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hopmann, K. H.; Šebestík, Jaroslav; Novotná, J.; Stensen, W.; Urbanová, M.; Svenson, J.; Svendsen, J. S.; Bouř, Petr; Ruud, K.

    2012-01-01

    Roč. 77, č. 2 (2012), s. 858-869 ISSN 0022-3263 R&D Projects: GA ČR GAP208/11/0105; GA MŠk(CZ) LH11033 Institutional research plan: CEZ:AV0Z40550506 Keywords : vibrational circular dichroism * Raman optical activity * absolute configuration * bioprospecting Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.564, year: 2012

  10. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  11. Characterisation of the flow regimes of arbitrary manoeuvre in absolute and relative frames

    CSIR Research Space (South Africa)

    Gledhill, Irvy MA

    2011-09-01

    Full Text Available Characterisation of the flow regimes of arbitrary manoeuvre in absolute and relative frames I. Gledhill1 and J. Nordstr?m2 1Aeronautical Systems Competency Area, Defence, Peace, Safety and Security Operational Unit, CSIR 2 Dept of Mathematics, U Link... perturbations: dynamic derivatives - Relative frame terms: ? Roohani and Skews 2007?2011 ? In the inertial frame: - Inoue et al. ? CSIR 2011 www.csir.co.za U=Uinf U=0 Theory Background to present work ? Transformation between...

  12. Absolute measurement of the $\\beta\\alpha$ decay of $^{16}$N

    CERN Multimedia

    We propose to study the $\\beta$-decay of $^{16}$N at ISOLDE with the aim of determining the branching ratio for $\\beta\\alpha$ decay on an absolute scale. There are indications that the previously measured branching ratio is in error by an amount significantly larger than the quoted uncertainty. This limits the precision with which the S-factor of the astrophysically important $^{12}$C($\\alpha, \\gamma)^{16}$O reaction can be determined.

  13. Comparison of absolute neutrophil to CD4 lymphocyte values as a ...

    African Journals Online (AJOL)

    1.5 x 109/L is therefore obviously not appropriate for people of negroid descent whose lower reference limit is ANC 1.3 x 109/L.6,7 Neutropenia remains the most common predisposing factor to infections in cancer pa- tients.1,8,9 The accepted definition of neutropenia is an absolute neutrophil count ≤ 1.5 x 109/L,8 though ...

  14. Determination of Absolute Configuration of Secondary Alcohols Using Thin-Layer Chromatography

    Science.gov (United States)

    Wagner, Alexander J.; Rychnovsky, Scott D.

    2013-01-01

    A new implementation of the Competing Enantioselective Conversion (CEC) method was developed to qualitatively determine the absolute configuration of enantioenriched secondary alcohols using thin-layer chromatography. The entire process for the method requires approximately 60 min and utilizes micromole quantities of the secondary alcohol being tested. A number of synthetically relevant secondary alcohols are presented. Additionally, 1H NMR spectroscopy was conducted on all samples to provide evidence of reaction conversion that supports the qualitative method presented herein. PMID:23593963

  15. Structure and Absolute Configuration of Ginkgolide B Characterized by IR- and VCD Spectroscopy

    DEFF Research Database (Denmark)

    Andersen, Niels Højmark; Christensen, N.J.; Lassen, Peter Rygaard

    2010-01-01

    Experimental and calculated (B3LYP/6-31G(d)) vibrational Circular dichroism (VCD) and IR spectra are compared, illustrating that the structure and absolute configuration of ginkgolide B (GB) may be characterized directly in solution. A conformational search for GB using MacroModel and subsequent ....... This is the first detailed investigation of the spectroscopic fingerprint region (850-1300 cm(-1)) of the natural product GB employing infrared absorption and VCD spectroscopy. Chirality 22:217-223, 2010....

  16. Measurement of absolute photo-ionization cross sections using magnesium magneto-optical traps

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, D.N.; Thomsen, J.W. [Niels Bohr Institute, Oersted Laboratory, Copenhagen (Denmark)]. E-mail: jwt@fys.ku.dk

    2002-05-14

    This paper reports on an experimental study of resonant photo-ionization of the 3s3p {sup 1}P{sub 1} level of magnesium using near-resonant light at 285 nm. We extract an absolute photo-ionization cross section of (8.1{+-}2.3)x10{sup -17} cm{sup 2} using a magneto-optical trap and compare this value to current theoretical calculations. We find good agreement between theory and experiment. (author)

  17. Absolute in situ energy calibration of luminosity calorimeters in the DELPHI experiment at LEP

    International Nuclear Information System (INIS)

    Bugge, L.; Dam, M.; Read, A.L.; Myrheim, J.; Skjevling, G.

    1993-01-01

    Methods to perform the absolute energy calibration of DELPHI's Small Angle Tagger luminosity calorimeters at LEP are presented and compared. The input was small angle Bhabha scattering events. A significant nonlinearity in the response of the calorimeters was observed. The conjugate gradient method was applied to solve the least squares problem. This method is particularly useful for least squares problems which are large, ill-behaved or even singular, and for cases with a sparse coefficient matrix. (orig.)

  18. Classical and quantum dynamics of a gravitational theory with absolute teleparallelism

    International Nuclear Information System (INIS)

    Azeredo Campos, R. de.

    1984-01-01

    The dynamics of an alternative theory of gravitation with absolute teleparallelism is sustied. In the Cauchy problem of this theory four constraint relations are obtained, as in general relativity, because of the existence of the manifold mapping group. Propagation equations for the dynamical variables are also derived by applying Dirac's Hamiltonian methods. In addition, an algebra of generators related to the global Lorentz group and the correspondence principle leading to a quantum version of the theory are also discussed. (author) [pt

  19. Absolute linestrengths in the H2O2 nu6 band

    Science.gov (United States)

    May, Randy D.

    1991-01-01

    Absolute linestrengths at 295 K have been measured for selected lines in the nu6 band of H2O2 using a tunable diode-laser spectrometer. H2O2 concentrations in a flowing gas mixture were determined by ultraviolet (uv) absorption at 254 nm using a collinear infrared (ir) and uv optical arrangement. The measured linestrengths are approx. 60 percent larger than previously reported values when absorption by hot bands in H2O2 is taken into account.

  20. Absolute calibration of photon-number-resolving detectors with an analog output using twin beams

    Energy Technology Data Exchange (ETDEWEB)

    Peřina, Jan, E-mail: jan.perina.jr@upol.cz [RCPTM, Joint Laboratory of Optics of Palacký University and Institute of Physics AS CR, 17. listopadu 12, 77146 Olomouc (Czech Republic); Haderka, Ondřej [Joint Laboratory of Optics of Palacký University and Institute of Physics AS CR, 17. listopadu 12, 771 46 Olomouc (Czech Republic); Allevi, Alessia [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, I-22100 Como (Italy); Bondani, Maria [Istituto di Fotonica e Nanotecnologie, CNR-IFN, I-22100 Como (Italy)

    2014-01-27

    A method for absolute calibration of a photon-number resolving detector producing analog signals as the output is developed using a twin beam. The method gives both analog-to-digital conversion parameters and quantum detection efficiency for the photon fields. Characteristics of the used twin beam are also obtained. A simplified variant of the method applicable to fields with high signal to noise ratios and suitable for more intense twin beams is suggested.

  1. Residual-interaction renormalization effect on the spherical-nuclei α-decay absolute widths

    International Nuclear Information System (INIS)

    Dumitresku, T.; Kadmenskij, S.G.; Lomachenkov, I.A.; Kholan, S.; Furman, V.I.

    1978-01-01

    In the framework of the shell model approximation for the probabilities of alpha-decay the exact formulas (for alpha-widths) taking into account the contribution of density dependent effective interaction between nucleons forming the emitted alpha-particle are obtained. In agreement with previous estimations the numerical calculation reveals that the inclusion of the above-mentioned interaction is followed by some decrease of absolute alpha-widths

  2. On the precision of absolute sensitivity calibration and specifics of spectroscopic quantities interpretation in tokamaks

    Czech Academy of Sciences Publication Activity Database

    Naydenkova, Diana; Weinzettl, Vladimír; Stöckel, Jan; Matějíček, Jiří

    2014-01-01

    Roč. 53, č. 34 (2014), s. 8123-8130 ISSN 1559-128X R&D Projects: GA ČR(CZ) GA14-12837S Institutional support: RVO:61389021 Keywords : Spectroscopy * emission * spectrometers * absolute calibration Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.784, year: 2014 http://dx.doi.org/10.1364/AO.53.008123

  3. Statistical Inversion of Absolute Permeability in Single-phase Darcy Flow

    KAUST Repository

    Strauss, Thilo

    2015-06-01

    In this paper, we formulate the permeability inverse problem in the Bayesian framework using total variation (TV) and fp (0 < p δ 2) regularization prior. We use the Markov Chain Monte Carlo (MCMC) method for sampling the posterior distribution to solve the ill-posed inverse problem. We present simulations to estimate the distribution for each pixel for the image reconstruction of the absolute permeability.

  4. Determination of local absolute detection efficiency of a ceratron with 55Fe Auger electrons

    International Nuclear Information System (INIS)

    Mori, C.; Sugiyama, T.; Watanabe, T.

    1983-01-01

    The local absolute detection efficiency of a Ceratron (channel electron multiplier made of ceramics) was determined with collimated Mn K Auger electrons ( 5 keV) emitted from 55 Fe as a function of electron incident position and applied voltage. The local efficiency at the channel inlet did not depend so much on the applied voltage. The efficiency at the funnel increased with the applied voltage, while it was always lower than that at the channel inlet. (orig.)

  5. Production and trapping of carbon clusters for absolute mass measurements at ISOLTRAP

    CERN Document Server

    Scheidenberger, C; Herfurth, F; Kellerbauer, A G; Kluge, H J; Koizumi, M; Schwarz, S; Schweikhard, L

    2002-01-01

    Singly-charged carbon clusters C/sub n//sup +/ (n >or= 1) have been produced by laser-induced desorption and fragmentation of C/sub 60/ fullerenes and have been injected into and stored in the Penning trap system of the ISOLTRAP mass spectrometer at ISOLDE/CERN. The present study is the first step to extend the until now direct mass measurements at ISOLTRAP to absolute mass measurements by using clusters of /sup 12/C. (10 refs).

  6. Dynamic Analysis of Offshore Oil Pipe Installation Using the Absolute Nodal Coordinate Formulation

    DEFF Research Database (Denmark)

    Nielsen, Jimmy D; Madsen, Søren B; Hyldahl, Per Christian

    2013-01-01

    The Absolute Nodal Coordinate Formulation (ANCF) has shown promising results in dynamic analysis of structures that undergo large deformation. The method relaxes the assumption of infinitesimal rotations. Being based in a fixed inertial reference frame leads to a constant mass matrix and zero......, are included to mimic the external forces acting on the pipe during installation. The scope of this investigation is to demonstrate the ability using the ANCF to analyze the dynamic behavior of an offshore oil pipe during installation...

  7. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Zhao, H. L.; Liu, Y., E-mail: liuyong@ipp.ac.cn; Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Domier, C. W.; Luhmann, N. C. [Department of Electrical and Computer Engineering, University of California at Davis, Davis, California 95616 (United States)

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  8. Masses and K-line absolute magnitudes of γ Leonis and 35 Comae

    International Nuclear Information System (INIS)

    Deming, D.; Dykton, M.

    1979-01-01

    The visual binary system γ Leonis consists of two K giants whose total mass was found by Wilson to be less than 0.6M/sub sun/ when a distance was obtained from K-line absolute magnitudes of both components. Since the orbital period of the system is of order 600 years, the orbital solution has usually been regarded as the most likely explanation of the anomalous mass. We have investigated the uniqueness of the orbital solution. We find that the individual orbital elements are only poorly determined, but that a 3 /P 2 is known to within +- 10%. The anomalous mass of this binary system implies either extensive mass-loss or the need for revisions in the K-line absolute magnitudes. We also investigate the binary system 35 Comae. Wilson has noted that in this system the K-line absolute magnitude of the G8 III primary component implies a total mass of 8 M/sub sun/. However the A component of 35 Comae is not sufficiently luminous to justify such a large total mass. The system has a period of order 700 years, and the uniqueness of the orbital solution is therefore suspect. However, in this case also we have investigated the uniqueness of the orbital solution and find that individual orbital elements are poorly determined, but that a 3 /P 2 is known to within +- 17%. We point out that 35 Comae is known to be very metal rich, in contrast to γ Leonis which is metal poor. We conclude that a composition-dependent correction to the K-line absolute magnitudes provides the simplest explanation of these mass anomalies. Such a correction would also give better agreement with the trigonometric parallaxes of these binary systems

  9. Effect of core/veneer thickness ratio and veneer translucency on absolute and relative translucency of CAD-On restorations

    Directory of Open Access Journals (Sweden)

    Mennatallah Mohie el-Din Wahba, (BDS, MSc

    2017-06-01

    Conclusions: Only veneer translucency had significant effect over contrast ratio values, while on the other hand, absolute translucency values were significantly affected by the core/veneer thickness ratio, veneer translucency and interaction between them. It was clear that absolute translucency measurements showed higher translucency values for the restorations than contrast ratio measurements.

  10. Absolute versus Relative Assessments of Individual Status in Status-Dependent Strategies in Stochastic Environments.

    Science.gov (United States)

    Tachiki, Yuuya; Koizumi, Itsuro

    2016-07-01

    Status-dependent strategies represent one of the most remarkable adaptive phenotypic plasticities. A threshold value for individual status (e.g., body size) is assumed above and below which each individual should adopt alternative tactics to attain higher fitness. This implicitly assumes the existence of an "absolute" best threshold value, so each individual chooses a tactic only on the basis of its own status. However, animals may be able to assess their status on the basis of surrounding individuals. This "relative" assessment considers a threshold value to be changeable depending on individual situations, which may result in significant differences in ecological and evolutionary dynamics compared with absolute assessment. Here, we incorporated Bayesian decision-making and adaptive dynamics frameworks to explore the conditions necessary for each type of assessment to evolve. Our model demonstrates that absolute assessment is always an evolutionarily stable strategy (ESS) in a stable environment, whereas relative assessment can be an ESS in stochastic environments. The consequences of future environmental change differ considerably depending on the assessment chosen. Our results underscore the need to better understand how individuals assess their own status when choosing alternative tactics.

  11. Direct infusion-SIM as fast and robust method for absolute protein quantification in complex samples

    Directory of Open Access Journals (Sweden)

    Christina Looße

    2015-06-01

    Full Text Available Relative and absolute quantification of proteins in biological and clinical samples are common approaches in proteomics. Until now, targeted protein quantification is mainly performed using a combination of HPLC-based peptide separation and selected reaction monitoring on triple quadrupole mass spectrometers. Here, we show for the first time the potential of absolute quantification using a direct infusion strategy combined with single ion monitoring (SIM on a Q Exactive mass spectrometer. By using complex membrane fractions of Escherichia coli, we absolutely quantified the recombinant expressed heterologous human cytochrome P450 monooxygenase 3A4 (CYP3A4 comparing direct infusion-SIM with conventional HPLC-SIM. Direct-infusion SIM revealed only 14.7% (±4.1 (s.e.m. deviation on average, compared to HPLC-SIM and a decreased processing and analysis time of 4.5 min (that could be further decreased to 30 s for a single sample in contrast to 65 min by the LC–MS method. Summarized, our simplified workflow using direct infusion-SIM provides a fast and robust method for quantification of proteins in complex protein mixtures.

  12. Absolute Soft X-ray Emission Measurements at the Nike Laser

    Science.gov (United States)

    Weaver, J.; Atkin, R.; Boyer, C.; Colombant, D.; Feldman, U.; Fielding, D.; Gardner, J.; Holland, G.; Klapisch, M.; Mostovych, A. N.; Obenscain, S.; Seely, J. F.

    2002-11-01

    Recent experiments at the Nike laser facility have demonstrated that, when a low intensity prepulse ( 2main laser intensity) is used to heat a thin Au or Pd coating on a planar CH target, the growth of non-uniformities due to laser imprint can be reduced from the growth observed for an uncoated CH target. The absolute radiation intensity in the soft x-ray region (0.1-1 keV) has a important role in the energy balance for layered targets. There is an ongoing effort to characterize the soft x-ray emission using an absolutely calibrated transmission grating spectrometer and filtered diode modules. Measurements of the angular distribution of the emission from unlayered solid targets (Au, Pd, CH) have recently been made using an array of moveable filtered diode modules. The data from the angular distribution studies will be presented. A new absolutely calibrated, time-resolving transmission grating spectrometer has been installed at the Nike. The new version has improved spectral resolution, selectable transmission filters, and the potential for simultaneous temporal, spatial, and spectral resolution. Preliminary data from the new spectrometer will be presented and future experiments will be briefly discussed. *Work was supported by DoE

  13. Absolute and relative emissions analysis in practical combustion systems—effect of water vapor condensation

    Science.gov (United States)

    Richter, J. P.; Mollendorf, J. C.; DesJardin, P. E.

    2016-11-01

    Accurate knowledge of the absolute combustion gas composition is necessary in the automotive, aircraft, processing, heating and air conditioning industries where emissions reduction is a major concern. Those industries use a variety of sensor technologies. Many of these sensors are used to analyze the gas by pumping a sample through a system of tubes to reach a remote sensor location. An inherent characteristic with this type of sampling strategy is that the mixture state changes as the sample is drawn towards the sensor. Specifically, temperature and humidity changes can be significant, resulting in a very different gas mixture at the sensor interface compared with the in situ location (water vapor dilution effect). Consequently, the gas concentrations obtained from remotely sampled gas analyzers can be significantly different than in situ values. In this study, inherent errors associated with sampled combustion gas concentration measurements are explored, and a correction methodology is presented to determine the absolute gas composition from remotely measured gas species concentrations. For in situ (wet) measurements a heated zirconium dioxide (ZrO2) oxygen sensor (Bosch LSU 4.9) is used to measure the absolute oxygen concentration. This is used to correct the remotely sampled (dry) measurements taken with an electrochemical sensor within the remote analyzer (Testo 330-2LL). In this study, such a correction is experimentally validated for a specified concentration of carbon monoxide (5020 ppmv).

  14. Double domain wavelength multiplexed Fizeau interferometer with high resolution dynamic sensing and absolute length detection

    Science.gov (United States)

    Antonacci, Julián; Arenas, Gustavo F.; Duchowicz, Ricardo

    2017-04-01

    In this work, we present a simple photonic instrument that has the ability of measuring positions, distances and vibrations with very high resolution by means of two Fizeau interferometers (FI), both using the same optical fiber end as a probe tip itself. On the one hand we have a time domain FI powered with a 1310 nm laser and monitored by an InGaAs detector providing displacement information with resolution around a tenth of nm but regardless of the absolute position of object and of the displacement sense. On the other, a spectral domain FI version based on a super luminescent source (SLED) centred at 800 nm with bandwidth of nearly 40 nm is analysed in real time by means of a digital spectrometer. Each spectrum is acquired in a very small time interval and provides information of both length of the cavity as well as its correct sense of evolution. Resolution of this system is lower than its complementary temporal case, but distance and sense measurements are absolute and can be determined successfully by adequate processing of spectral signal.Both interferometers are optically coupled to a single fiber optic probe and are wavelength modulated.Therefore, combination of both sensors results in a new one which allows the correct knowledge of an object or surfaces under test, i.e. a high resolution of displacement data plus its absolute position and true sense of movement.

  15. Absolute Calibration of Si iRMs used for Si Paleo-nutrient proxies

    Science.gov (United States)

    Vocke, Robert; Rabb, Savelas

    2016-04-01

    The Avogadro Project is an ongoing international effort, coordinated by the International Bureau of Weights and Measures (BIPM) and the International Avogadro Coordination (IAC) to redefine the SI unit mole in terms of the Avogadro constant and the SI unit kg in terms of the Planck constant. One of the outgrowths of this effort has been the development of a novel, precise and highly accurate method to measure calibrated (absolute) isotopic ratios that are traceable to the SI (Vocke et al., 2014 Metrologia 51, 361, Azuma et al., 2015 Metrologia 52 360). This approach has also been able to produce absolute Si isotope ratio data with lower levels of uncertainty when compared to the traditional "Atomic Weights" method of absolute isotope ratio measurement. Silicon isotope variations (reported as delta(Si30)and delta(Si29)) in silicic acid dissolved in ocean waters, in biogenic silica and in diatoms are extremely informative paleo-nutrient proxies. The utility and comparability of such measurements however depends on calibration with artifact isotopic Reference Materials (iRMs). We will be reporting new measurements on the iRMs NBS-28 (RM 8546 - Silica Sand), Diatomite, Big Batch and SRM 990 using the Avogadro measurement approach, comparing them with prior assessments of these iRMs.

  16. Selective segmental sclerotherapy of the liver by transportal absolute ethanol injection: an animal experimental study

    International Nuclear Information System (INIS)

    Pan Jie; Yang Ning; Zhang Zhongzhong; Hu Libin; Chen Jie; Wu Wei; Jin Zhengyu; Liu Wei

    2003-01-01

    Objective: To evaluate the safety and efficacy of selective segmental sclerotherapy (SSS) of the liver by transportal absolute ethanol injection with an animal experimental study, and to discuss several technical points involved in this method. Methods: Thirty dogs received SSS of the liver by transportal absolute ethanol injection with the injection dose of 0.2-1.0 ml/kg, repeated examinations of blood ethanol level, WBC, and liver functions were done, and CT and pathological examinations of the liver were performed. Results: All dogs treated with SSS survived during the study. The maximum elevation of blood ethanol values occurred in group F. Its average value was (1.603 ± 0.083) mg/ml, which was much lower than that of death level. Transient elevations of blood WBC and ALT were seen. The average values of WBC and ALT were (46.36 ± 7.28) x 10 9 and (827.36 ± 147.25) U/L, respectively. CT and pathological examinations proved that the dogs given SSS by transportal absolute ethanol injection with the injection dose of 0.3-1.0 ml/kg had a complete wedge-shaped necrosis in the liver. Conclusion: Selective segmental sclerotherapy of the liver by transportal ethanol injection was quite safe and effective if the proper dose of ethanol was injected. SSS may be useful in the treatment of HCC

  17. Absolute oral bioavailability and disposition of deferasirox in healthy human subjects.

    Science.gov (United States)

    Séchaud, Romain; Robeva, Anna; Belleli, Rossella; Balez, Sebastien

    2008-08-01

    Deferasirox is a novel iron chelator formulated as tablets for dispersion (suspension) for once-a-day oral administration. The current study evaluated the absolute bioavailability of a single 375-mg oral dose of deferasirox administered in the form of tablets compared with a 130-mg intravenous infusion of deferasirox. Since this was a first-in-man study using the deferasirox intravenous (IV) formulation, the safety and tolerability of the IV formulation was evaluated in a pilot phase with a lower dose (65 mg) in 3 subjects prior to the main phase. The main study phase consisted of 17 healthy male volunteers. Plasma concentrations of deferasirox were measured following each treatment, and pharmacokinetic parameters including absolute oral bioavailability were determined. Absolute oral bioavailability of the deferasirox tablets was 70% (90% confidence interval, 62%-80%). Deferasirox was characterized as having a low plasma clearance of 3.53 (+/- 0.87) L/h. A small volume of distribution of deferasirox at steady state (V(ss)) of 14.37 (+/-2.69 L) was determined, indicating a low tissue distribution.

  18. Accurate measurement of the optical activity of alanine crystals and the determination of their absolute chirality

    Science.gov (United States)

    Ishikawa, Kazuhiko; Terasawa, Yukana; Tanaka, Masahito; Asahi, Toru

    2017-05-01

    Wavelength dependence measurements of the chiroptical properties in alanine crystals have so far been unsuccessful using conventional spectroscopic techniques. We describe our attempts to measure the wavelength dependence of the optical activity in L- and D-alanine crystals along each crystallographic axis, and to determine the absolute chirality of alanine crystals by correlating the absolute structure to the optical activity using an x-ray diffractometer and a generalized high accuracy universal polarimeter. We have succeeded in accurately measuring the optical rotatory dispersion in the direction, which shows that the optical rotation of the D-alanine crystal is dextrorotatory and that of the L-alanine crystal is laevorotatory, thereby determining the absolute chirality. Furthermore, comparison with the optical activity in solution shows that the optical activity in alanine crystals is different not only in value, but also in the sign. These results have led us to conclude that the optical rotatory power in the crystalline state should not be simply the summation of molecular optical rotatory power values. We propose the necessity of a theory, which contains the contribution of molecular interactions within the crystal, in order to calculate the optical rotatory power of the crystalline state.

  19. Calculating Absolute Transition Probabilities for Deformed Nuclei in the Rare-Earth Region

    Science.gov (United States)

    Stratman, Anne; Casarella, Clark; Aprahamian, Ani

    2017-09-01

    Absolute transition probabilities are the cornerstone of understanding nuclear structure physics in comparison to nuclear models. We have developed a code to calculate absolute transition probabilities from measured lifetimes, using a Python script and a Mathematica notebook. Both of these methods take pertinent quantities such as the lifetime of a given state, the energy and intensity of the emitted gamma ray, and the multipolarities of the transitions to calculate the appropriate B(E1), B(E2), B(M1) or in general, any B(σλ) values. The program allows for the inclusion of mixing ratios of different multipolarities and the electron conversion of gamma-rays to correct for their intensities, and yields results in absolute units or results normalized to Weisskopf units. The code has been tested against available data in a wide range of nuclei from the rare earth region (28 in total), including 146-154Sm, 154-160Gd, 158-164Dy, 162-170Er, 168-176Yb, and 174-182Hf. It will be available from the Notre Dame Nuclear Science Laboratory webpage for use by the community. This work was supported by the University of Notre Dame College of Science, and by the National Science Foundation, under Contract PHY-1419765.

  20. Commissioning of the Absolute Luminosity For ATLAS detector at the LHC

    CERN Document Server

    Jakobsen, Sune; Hansen, Peter; Hansen, Jørgen Beck

    The startup of the LHC (Large Hadron Collider) has initialized a new era in particle physics. The standard model of particle physics has for the last 40 years with tremendous success described all measurements with phenomenal precision. The experiments at the LHC are testing the standard model in a new energy regime. To normalize the measurements and understand the potential discoveries of the LHC experiments it is often crucial to know the interaction rate - the absolute luminosity. The ATLAS (A Toroidal LHC ApparatuS) detector will measure luminosity by numerous methods. But for most of the methods only the relative luminosity is measured with good precision. The absolute scale has to be provided from elsewhere. ATLAS is like the other LHC experiments mainly relying of absolute luminosity calibration from van der Meer scans (beam separation scans). To cross check and maybe even improve the precision; ATLAS has built a sub-detector to measure the flux of protons scattered under very small angles as this flux...

  1. Flow rate calibration I: a novel approach for performing absolute cell counts.

    Science.gov (United States)

    Storie, Ian; Sawle, Alex; Goodfellow, Karen; Whitby, Liam; Granger, Vivian; Reilly, John T; Barnett, David

    2003-09-01

    Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC). FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4(+) T-lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates. A high degree of linearity over a wide range of counts (50 to >1,600 CD4(+) T lymphocytes/microl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used. Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided. Copyright 2003 Wiley-Liss, Inc.

  2. Komposisi Kimia Absolut Minyak Atsiri Daun Pandan Wangi Hasil Perlakuan Curing

    Directory of Open Access Journals (Sweden)

    NiMade Wartini

    2015-03-01

    Full Text Available Tujuan penelitian ini adalah  untuk mengetahui pengaruh lama curing pada daun pandan wangi terhadap karakteristik absolute minyak atsiri daun pandan wangi yang dihasilkan. Perlakuan lama curing terdiri atas 3 taraf yaitu tanpa curing, curing 2, dan curing 4 hari. Curing daun pandan wangi dilakukan secara alami dihamparkan di atas meja kayu pada suhu dan RH ruangan. Selama curing dilakukan pengadukan bahan secara intensif setiap 6 jam, pengukuran temperatur dan RH ruang setiap 12 jam. Daun pandan wangi hasil  curing diambil minyak atsirinya dengan ekstraksi pelarut n-heksana selama 4 jam dilanjutkan dengan re-ekstraksi dengan etanol pada perbandingan 1:8 pada suhu 70 oC selama 30 menit.  Hasil penelitian menunjukkan bahwa perlakuan curing pada daun pandan wangi berpengaruh terhadap komposisi kimia absolute minyak atsiri daun pandan wangi yang dihasilkan. Komposisi kimia absolute minyak atsiri daun pandan hasil perlakuan curing terdiri atas golongan senyawa alkana (12,58-14,88%, alkena (20,09-30,24%, benzene (3,85-41,17%,  alkohol (4,55-9,42%,  fenol (0-12,47%, terpen (8,72-12,05%, dan ester (0-4,49%.

  3. Measurement of definite integral of sinusoidal signal absolute value third power using digital stochastic method

    Directory of Open Access Journals (Sweden)

    Beljić Željko

    2017-01-01

    Full Text Available In this paper a special case of digital stochastic measurement of the third power of definite integral of sinusoidal signal’s absolute value, using 2-bit AD converters is presented. This case of digital stochastic method had emerged from the need to measure power and energy of the wind. Power and energy are proportional to the third power of wind speed. Anemometer output signal is sinusoidal. Therefore an integral of the third power of sinusoidal signal is zero. Two approaches are proposed for the third power calculation of the wind speed signal. One approach is to use absolute value of sinusoidal signal (before AD conversion for which there is no need of multiplier hardware change. The second approach requires small multiplier hardware change, but input signal remains unchanged. For the second approach proposed minimal hardware change was made to calculate absolute value of the result after AD conversion. Simulations have confirmed theoretical analysis. Expected precision of wind energy measurement of proposed device is better than 0,00051% of full scale. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR32019

  4. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Directory of Open Access Journals (Sweden)

    H.-P. Brunke

    2018-01-01

    Full Text Available At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer. Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996.We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017.

  5. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Science.gov (United States)

    Brunke, Heinz-Peter; Matzka, Jürgen

    2018-01-01

    At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer). Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination) measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996).We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters) of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017).

  6. Prediction of absolute infrared intensities for the fundamental vibrations of H2O2

    Science.gov (United States)

    Rogers, J. D.; Hillman, J. J.

    1981-01-01

    Absolute infrared intensities are predicted for the vibrational bands of gas-phase H2O2 by the use of a hydrogen atomic polar tensor transferred from the hydroxyl hydrogen atom of CH3OH. These predicted intensities are compared with intensities predicted by the use of a hydrogen atomic polar tensor transferred from H2O. The predicted relative intensities agree well with published spectra of gas-phase H2O2, and the predicted absolute intensities are expected to be accurate to within at least a factor of two. Among the vibrational degrees of freedom, the antisymmetric O-H bending mode nu(6) is found to be the strongest with a calculated intensity of 60.5 km/mole. The torsional band, a consequence of hindered rotation, is found to be the most intense fundamental with a predicted intensity of 120 km/mole. These results are compared with the recent absolute intensity determinations for the nu(6) band.

  7. Clinical observation of phacoemulsification combined goniosynechialysis in treating absolute glaucoma after trabeculectomy

    Directory of Open Access Journals (Sweden)

    Jun-Yong Wang

    2014-10-01

    Full Text Available AIM: To observe the effect of phacoemulsification combined goniosynechialysis in treating absolute glaucoma after trabeculectomy.METHODS: Phacoemulsification combined goniosynechialysis was performed on 16 patients(16 eyeswith absolute glaucoma after trabeculectomy, and they were followed up for 6~12mo, The postoperative intraocular pressure(IOPand anterior chamber depth, preoperative and postoperative medication types(quantity, preoperative and postoperative 1 month's status of anxiety and depression, symptoms of ocular surface were observed.RESULTS: The IOP decreased significantly after phacoemulsification combined goniosynechialysis. The mean IOP was 35.00±15.43mmHg preoperatively, and it was 12.00±6.69mmHg, 15.00±4.26mmHg and 15.3±5.2mmHg on 1d, 6 and 12mo after the surgery. The statistic difference was found between preoperative and postoperative(t=6.22, Pt=6.65, PCONCLUSION: Phacoemulsification combined goniosynechialysis in treating absolute glaucoma after trabeculectomy is a safe and effective surgical option.

  8. Establishment of an absolute chronology for the 18th Egyptian Dynasty

    International Nuclear Information System (INIS)

    Quiles, A.

    2011-01-01

    The establishment of an absolute chronology for Ancient Egypt is an ambition which has concentrated efforts of many scholars since the beginning of Egyptology. Thanks to historical and archaeological documents, a relative chronology of the kings has been built. Only some astrophysical points and synchronisms listed in texts (Greek and Egyptian sources) have given some ankle points which have led to some propositions of absolute chronology. At first, we will see how we can re-calculate some ankle points by using Sothic dating and modelling lunar dates with a Bayesian approach. Then, radiocarbon measurements have been done at Laboratoire de Mesure du Carbone 14 (CEA Saclay) on Egyptian short life materials like plants or twigs. These objects come from the Louvre Museum and are attributed to a particular reign and a precise period. With a Bayesian approach, these analyses have been combined with the known succession and length of the reign. Besides, Sothic and lunar dates have been incorporated as a prior in the model. It has led to propose an absolute chronology for the 18th dynasty. Finally, we will discuss the agreement between our results and archaeological evidence and will see if this chronology can highlight points where Egyptologists disagree. (author)

  9. Zero absolute vorticity: insight from experiments in rotating laminar plane Couette flow.

    Science.gov (United States)

    Suryadi, Alexandre; Segalini, Antonio; Alfredsson, P Henrik

    2014-03-01

    For pressure-driven turbulent channel flows undergoing spanwise system rotation, it has been observed that the absolute vorticity, i.e., the sum of the averaged spanwise flow vorticity and system rotation, tends to zero in the central region of the channel. This observation has so far eluded a convincing theoretical explanation, despite experimental and numerical evidence reported in the literature. Here we show experimentally that three-dimensional laminar structures in plane Couette flow, which appear under anticyclonic system rotation, give the same effect, namely, that the absolute vorticity tends to zero if the rotation rate is high enough. It is shown that this is equivalent to a local Richardson number of approximately zero, which would indicate a stable condition. We also offer an explanation based on Kelvin's circulation theorem to demonstrate that the absolute vorticity should remain constant and approximately equal to zero in the central region of the channel when going from the nonrotating fully turbulent state to any state with sufficiently high rotation.

  10. Conditional associative memory for musical stimuli in nonmusicians: implications for absolute pitch.

    Science.gov (United States)

    Bermudez, Patrick; Zatorre, Robert J

    2005-08-24

    A previous positron emission tomography (PET) study of musicians with and without absolute pitch put forth the hypothesis that the posterior dorsolateral prefrontal cortex is involved in the conditional associative aspect of the identification of a pitch. In the work presented here, we tested this hypothesis by training eight nonmusicians to associate each of four different complex musical sounds (triad chords) with an arbitrary number in a task designed to have limited analogy to absolute-pitch identification. Each subject under-went a functional magnetic resonance imaging scanning procedure both before and after training. Active condition (identification of chords)-control condition (amplitude-matched noise bursts) comparisons for the pretraining scan showed no significant activation maxima. The same comparison for the posttraining scan revealed significant peaks of activation in posterior dorsolateral prefrontal, ventrolateral prefrontal, and parietal areas. A conjunction analysis was performed to show that the posterior dorsolateral prefrontal activity in this study is similar to that observed in the aforementioned PET study. We conclude that the posterior dorsolateral prefrontal cortex is selectively involved in the conditional association aspect of our task, as it is in the attribution of a verbal label to a note by absolute-pitch musicians.

  11. Wall Effect on the Convective-Absolute Boundary for the Compressible Shear Layer

    Science.gov (United States)

    Robinet, Jean-Christophe; Dussauge, Jean-Paul; Casalis, Grégoire

    The linear stability of inviscid compressible shear layers is studied. When the layer develops at the vicinity of a wall, the two parallel flows can have a velocity of the same sign or of opposite signs. This situation is examined in order to obtain first hints on the stability of separated flows in the compressible regime. The shear layer is described by a hyperbolic tangent profile for the velocity component and the Crocco relation for the temperature profile. Gravity effects and the superficial tension are neglected. By examining the temporal growth rate at the saddle point in the wave-number space, the flow is characterized as being either absolutely unstable or convectively unstable. This study principally shows the effect of the wall on the convective-absolute transition in compressible shear flow. Results are presented, showing the amount of the backflow necessary to have this type of transition for a range of primary flow Mach numbers M1 up to 3.0. The boundary of the convective-absolute transition is defined as a function of the velocity ratio, the temperature ratio and the Mach number. Unstable solutions are calculated for both streamwise and oblique disturbances in the shear layer.

  12. Measurement of absolute neutron flux in LWSCR based on the nuclear track method

    International Nuclear Information System (INIS)

    Sadeghzadeh, J.; Nassiri Mofakham, N.; Khajehmiri, Z.

    2012-01-01

    Highlights: ► Up to now the spectral parameters of thermal neutrons are measured with activation foils that are not always reliable in low flux systems. ► We applied a solid state nuclear track detector to measure the absolute neutron flux in the light water sub-critical reactor (LWSCR). ► Experiments concerning fission track detecting were performed and were investigated using the Monte Carlo code MCNP. ► The neutron fluxes obtained in experiment are in fairly good agreement with the results obtained by MCNP. - Abstract: In the present paper, a solid state nuclear track detector is applied to measure the absolute neutron flux in the light water sub-critical reactor (LWSCR) in Nuclear Science and Technology Research Institute (NSTRI). Up to now, the spectral parameters of thermal neutrons have been measured with activation foils that are not always reliable in low flux systems. The method investigated here is the irradiation method. Experiments concerning fission track detecting were performed. The experiment including neutron flux calculation method has also been investigated using the Monte Carlo code MCNP. The analysis shows that the values of neutron flux obtained by experiment are in fairly good agreement with the results obtained by MCNP. Thus, this method may be able to predict the absolute value of neutron flux at LWSCR and other similar reactors.

  13. Absolute determination of the temperature-dependent penetration depth in superconducting V3Si

    International Nuclear Information System (INIS)

    Christen, D.K.; Sekula, S.T.; Kerchner, H.R.; Chang, Y.K.

    1985-01-01

    The temperature-dependent penetration depth lambda(T) is the fundamental length that describes the spatial variation of a static magnetic field within a superconductor, including the field decay from the core of an isolated flux line (FL) in a type-II superconductor in the mixed state. The penetration depth has been the subject of extensive investigation in a number of superconducting pure materials and alloys. Few experimental techniques enable an absolute determination of lambda; usually one may obtain only relative changes with temperature. The authors have shown that for an extreme (high-kappa) type-II superconductor, such as V 3 Si, it is possible to measure lambda(T) absolutely from the low-field flux-line lattice (FLL) form factor F/sub hk/, which is extracted from the intensity of neutrons diffracted at small angles from the FLL. Since this technique provides an absolute determination, it enables a direct comparison to the predictions of microscopic theory. Here the authors compare the observed lambda to the BCS theory and its modifications due to many-body effects

  14. China's electricity market-oriented reform: From an absolute to a relative monopoly

    International Nuclear Information System (INIS)

    Wang, Qiang; Chen, Xi

    2012-01-01

    The market-oriented reform in electricity industry has become a global trend since 1980s. Although China's electricity industry has been reformed since 1978, the substantial reform has not been conducted until 1985. Before 1985, China's power industry had been absolutely monopolized by the central state-owned companies. The absolute monopoly has been broken since 1985, when the Chinese government opened doors for non-central state-owned investment entities and foreign investors in power supplies in order to solve the chronic power shortage. In 2002, the comprehensive electricity reform plan entitled Scheme of the Reform for Power Industry was enacted. However, implementation of this plan was delayed due to electricity supply shortages. Even worse, a new kind of monopoly has been developed under the background “the state advances, the private sector retreats” in late years. In some sense, the former absolute monopoly has transformed the current relative monopoly. We contend that the relative monopoly has reversed the market-oriented reform in China's electric industry. If the relative monopoly remains unchanged, it will be harmful to public welfare.

  15. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature.

    Science.gov (United States)

    Schmuck, S; Fessey, J; Gerbaud, T; Alper, B; Beurskens, M N A; de la Luna, E; Sirinelli, A; Zerbini, M

    2012-12-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron temperature is determined from the measurements. The current state of the interferometer hardware, the calibration setup, and the analysis technique for calibration and plasma operation are described. A new, full-system, absolute calibration employing continuous data acquisition has been performed recently and the calibration method and results are presented. The noise level in the measurement is very low and as a result the electron cyclotron emission spectrum and thus the spatial profile of the electron temperature are determined to within ±5% and in the most relevant region to within ±2%. The new calibration shows that the absolute response of the system has decreased by about 15% compared to that measured previously and possible reasons for this change are presented. Temperature profiles measured with the Michelson interferometer are compared with profiles measured independently using Thomson scattering diagnostics, which have also been recently refurbished and recalibrated, and agreement within experimental uncertainties is obtained.

  16. Method for determining the absolute number concentration of nanoparticles from electrospray sources.

    Science.gov (United States)

    Li, Mingdong; Guha, Suvajyoti; Zangmeister, Rebecca; Tarlov, Michael J; Zachariah, Michael R

    2011-12-20

    We have developed a simple, fast, and accurate method to measure the absolute number concentration of nanoparticles in solution. The method combines electrospray differential mobility analysis (ES-DMA) with a statistical analysis of droplet-induced oligomer formation. A key feature of the method is that it allows determination of the absolute number concentration of particles by knowing only the droplet size generated from a particular ES source, thereby eliminating the need for sample-specific calibration standards or detailed analysis of transport losses. The approach was validated by comparing the total number concentration of monodispersed Au nanoparticles determined by ES-DMA with UV/vis measurements. We also show that this approach is valid for protein molecules by quantifying the absolute number concentration of Rituxan monoclonal antibody in solution. The methodology is applicable for quantification of any electrospray process coupled to an analytical tool that can distinguish monomers from higher order oligomers. The only requirement is that the droplet size distribution be evaluated. For users only interested in implementation of the theory, we provide a section that summarizes the relevant formulas. This method eliminates the need for sample-specific calibration standards or detailed analysis of transport losses. © 2011 American Chemical Society

  17. The comparison of absolute dating (Radiocarbon dating) and relative dating of Pringapus and Gondosuli temples

    International Nuclear Information System (INIS)

    Faisal, W; Arumbinang, H; Taftazani, A; Widayati, S; Sumiyatno; Suhardi

    1996-01-01

    The absolute dating (radiocarbon, 14 C dating) and relative dating of Pringapus and Gondosuli temples in Temanggung regency (district) of Central Java Province have been carried out. The field sampling was done especially with the purpose to obtain vertical data, so that excavation method was adopted in the case. The main data were the ecofacts of organic habitation such as bones, woods, charcoals, shells, and paper artefacts. The artefacts data were used as a comparison. The comparative data analysis were conducted at Yogyakarta archaeological Department Laboratory, thus included dating of artefacts which were performed according to archaeological analysis procedures, generally based on the attributes attached to the artefacts, whereas the absolute dating of charcoal samples were performed in the Radiocarbon Dating Laboratory at Yogyakarta Nuclear Research Centre. Based on the relative dating of epigraphy content on the andesit rock from Gondosuli Temple which showed the year of 754 Saka or 832 AD, the Pringapus Temple was estimated to be built in the 850 AD. According to the absolute dating (Radiocarbon Dating with delta 13 C and tree ring corrections) the age for Gondosuli temple based on GDS/LU-2/Spit-7 samples is (384 -602) AD and from GDS/LU-2/Spit-8 = (452 - 652) AD. With these significant differences in the results obtained, it can be concluded that culture environment where the sample were collected already existed before the temple was built. Further investigation is still required

  18. Automated haematology analysis to diagnose malaria

    Directory of Open Access Journals (Sweden)

    Grobusch Martin P

    2010-11-01

    Full Text Available Abstract For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn®, Coulter® GEN·S and LH 750, and the Sysmex XE-2100® analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the

  19. [Establishment and evaluation of review criteria for ADVIA 120/2120 and different series of hematology analyzers].

    Science.gov (United States)

    Xing, Ying; Wang, Jian-Zhong; Pu, Cheng-Wei; Shang, Ke; Yan, Zhen-Lin; Bai, Yu-Zhu; Yang, Wen-Shuang; Li, Tao; Zhang, Shi-Min

    2010-06-08

    To establish the suitable review criteria for ADVIA 120/2120 and those for different series of hematology analyzers. A total of 2400 samples, including 6 blood neoplasms, were detected with ADVIA 120/2120 hematology analyzer, in which 1200 samples were detected by Sysmex XE-2100 and Beckman-Coulter LH750 hematology analyzers. In the meantime, blood smears were reviewed, and the results were analyzed statistically. The new review criteria were established by consulting and modifying the one as recommended by an international consensus group. Finally 300 samples were selected to validate the new review criteria. The results of 2400 samples detected by ADVIA 120/2120 hematology analyzer were analyzed statistically according to the international consensus review rules and blood smear positive criteria formulated by Chinese experts. The true positive rate was 22.1% (n = 530), false positive rate 28.1% (n = 675), true negative rate 44.3% (n = 1063), false negative rate 5.5% (n = 132), and the smear review rate 50.2% (n = 1205). The false negative rate was over the acceptable limit of 5%. The new review criteria were established by amending the blood smear positive criteria, i. e. increasing the percentage of band neutrophils, eosinophils, basophils and monocytes and adjusting the international consensus review rules. Then the results were re-analyzed. The true positive rate, false positive rate, true negative rate and false negative rate were 15.5% (n = 371), 18.7% (n = 449), 61.6% (n = 1479) and 4.2% (n = 101) respectively. The smear review rate was 34.2% (n = 821) and no specimen of blood neoplasms was missed. On that basis, the current review criteria for ADVIA 120/2120, XE-2100 and LH750 hematology analyzer were proposed by adding some specific parameters. The results of 1200 samples with three instruments were analyzed according to the current criteria. And the false negative rates were 4.3%, 4.6% and 4.6%, and false positive rate 14.7%, 17.5% and 12.7% respectively

  20. Communicating cardiovascular disease risk: an interview study of General Practitioners' use of absolute risk within tailored communication strategies.

    Science.gov (United States)

    Bonner, Carissa; Jansen, Jesse; McKinn, Shannon; Irwig, Les; Doust, Jenny; Glasziou, Paul; McCaffery, Kirsten

    2014-05-29

    Cardiovascular disease (CVD) prevention guidelines encourage assessment of absolute CVD risk - the probability of a CVD event within a fixed time period, based on the most predictive risk factors. However, few General Practitioners (GPs) use absolute CVD risk consistently, and communication difficulties have been identified as a barrier to changing practice. This study aimed to explore GPs' descriptions of their CVD risk communication strategies, including the role of absolute risk. Semi-structured interviews were conducted with a purposive sample of 25 GPs in New South Wales, Australia. Transcribed audio-recordings were thematically coded, using the Framework Analysis method to ensure rigour. GPs used absolute CVD risk within three different communication strategies: 'positive', 'scare tactic', and 'indirect'. A 'positive' strategy, which aimed to reassure and motivate, was used for patients with low risk, determination to change lifestyle, and some concern about CVD risk. Absolute risk was used to show how they could reduce risk. A 'scare tactic' strategy was used for patients with high risk, lack of motivation, and a dismissive attitude. Absolute risk was used to 'scare' them into taking action. An 'indirect' strategy, where CVD risk was not the main focus, was used for patients with low risk but some lifestyle risk factors, high anxiety, high resistance to change, or difficulty understanding probabilities. Non-quantitative absolute risk formats were found to be helpful in these situations. This study demonstrated how GPs use three different communication strategies to address the issue of CVD risk, depending on their perception of patient risk, motivation and anxiety. Absolute risk played a different role within each strategy. Providing GPs with alternative ways of explaining absolute risk, in order to achieve different communication aims, may improve their use of absolute CVD risk assessment in practice.