Sample records for sweat chloride test

  1. Biological variability of the sweat chloride in diagnostic sweat tests: A retrospective analysis.

    Science.gov (United States)

    Vermeulen, F; Lebecque, P; De Boeck, K; Leal, T

    2017-01-01

    The sweat test is the current gold standard for the diagnosis of cystic fibrosis (CF). CF is unlikely when sweat chloride (Cl sw ) is lower than 30mmol/L, Cl sw >60 is suggestive of CF, with intermediate values between 30 and 60mmol/L. To correctly interpret a sweat chloride value, the biological variability of the sweat chloride has to be known. Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Cl sw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion. Within test variability of Cl sw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Cl sw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102). Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  2. Normal sweat chloride test does not rule out cystic fibrosis.

    Science.gov (United States)

    Başaran, Abdurrahman Erdem; Karataş-Torun, Nimet; Maslak, İbrahim Cemal; Bingöl, Ayşen; Alper, Özgül M

    2017-01-01

    Başaran AE, Karataş-Torun N, Maslak İC, Bingöl A, Alper ÖM. Normal sweat chloride test does not rule out cystic fibrosis. Turk J Pediatr 2017; 59: 68-70. A 5-month-old patient presented with complaints of fever and cough. He was hospitalized with the diagnosis of bronchopneumonia and pseudo-Bartter's syndrome. Patient was further investigated for diagnosis of cystic fibrosis. The chloride (Cl) level in sweat was determined within the normal range (25.1 mmol/L, 20.3 mmol/L). CFTR (Cystic Fibrosis Transmembrane Regulator gene; NM_000492.2) genotyping results were positive for p.E92K; p.F1052V mutations. The patient was diagnosed with cystic fibrosis. In our patient, with features of CF and normal sweat test, mutation analysis was helpful for the diagnosis of cystic fibrosis.

  3. Sweat electrolytes test

    Science.gov (United States)

    Sweat test; Sweat chloride; Iontophoretic sweat test; CF - sweat test; Cystic fibrosis - sweat test ... A colorless, odorless chemical that causes sweating is applied to a small area on an arm or leg. An electrode is then attached to the spot. A weak electrical ...

  4. Quality of sweat test (ST) based on the proportion of sweat sodium (Na) and sweat chloride (Cl) as diagnostic parameter of cystic fibrosis: are we on the right way?

    Science.gov (United States)

    Faria, Alethéa Guimarães; Marson, Fernando Augusto Lima; Gomez, Carla Cristina de Souza; Ribeiro, Maria Ângela Gonçalves de Oliveira; Morais, Lucas Brioschi; Servidoni, Maria de Fátima; Bertuzzo, Carmen Sílvia; Sakano, Eulália; Goto, Maura; Paschoal, Ilma Aparecida; Pereira, Mônica Corso; Hessel, Gabriel; Levy, Carlos Emílio; Toro, Adyléia Aparecida Dalbo Contrera; Peixoto, Andressa Oliveira; Simões, Maria Cristina Ribeiro; Lomazi, Elizete Aparecida; Nogueira, Roberto José Negrão; Ribeiro, Antônio Fernando; Ribeiro, José Dirceu

    2016-10-26

    To assess the quality of sweat test (ST) based on the proportion of sweat sodium and sweat chloride as diagnostic parameter of cystic fibrosis (CF). A retrospective study of 5,721 sweat samples and subsequent descriptive analysis were carried out. The test was considered "of good quality" (correct) when: (i) sweat chloride was lower than 60 mEq/L, and sweat sodium was higher than sweat chloride; (ii) sweat chloride was higher than 60 mEq/L, and sweat sodium was lower than sweat chloride. The study included 5,692/5,721 sweat samples of ST which had been requested due to clinical presentations compatible with CF and/or neonatal screenings with altered immunoreactive trypsinogen values. Considering the proportion of sweat sodium and sweat chloride as ST quality parameter, the test was performed correctly in 5,023/5,692 (88.2 %) sweat samples. The sweat chloride test results were grouped into four reference ranges for chloride (i) chloride sweat weight (p = 0.416). However, there was a positive association with: (i) gender, (ii) results of ST (p sweat chloride/sodium ratio (p sweat chloride values (p = 0.047), (iii) subject's age at the time of the ST grouped by numerical order (p = 0.001). Considering that the quality of ST can be assessed by levels of sweat sodium and sweat chloride, an increasing number of low-quality tests could be observed in our sweat samples. The quality of the test was associated with important factors, such as gender, CF diagnosis, and subjects' age.

  5. A case of localized adrenergic urticaria mimicking an allergic reaction to a sweat chloride test.

    Science.gov (United States)

    Klebanova, Y; LeGrys, V; Cooper, D; Levy, D; Santora, D; Schwindt, C

    2009-09-01

    Adrenergic urticaria (AU) is a rare type of physical urticaria triggered by stress. It is frequently confused with IgE-mediated urticaria or other physical urticarias. This report describes a case of localized adrenergic urticaria triggered by a sweat chloride test in an adolescent male with multiple atopic disorders. A pruritic papular rash at the site of a sweat chloride test prompted an evaluation for allergic and physical urticarias using multiple skin test methods. A positive intradermal skin test to noradrenaline, which reproduced the rash observed during the sweat test, lead to the diagnosis of adrenergic urticaria. This is the first case report describing an immediate adrenergic urticarial reaction to sweat chloride testing in a patient with other atopic disorders. Copyright 2009 Wiley-Liss, Inc.

  6. Biological Variation of Chloride and Sodium in Sweat Obtained by Pilocarpine Iontophoresis in Adults: How Sure are You About Sweat Test Results?

    Science.gov (United States)

    Willems, Philippe; Weekx, Steven; Meskal, Anissa; Schouwers, Sofie

    2017-04-01

    The measurement of chloride and sodium concentrations in sweat is an important test for the diagnosis of cystic fibrosis (CF). The aim of this study was to assess the analytical variation (CV A ) and within-subject (CV I ) and between-subject (CV G ) biological variation of chloride and sodium concentrations in sweat, collected by pilocarpine iontophoresis and to determine their effect on the clinical interpretation of sweat test results. Twelve Caucasian adults (six male and six female) without symptoms suggestive for CF and with a mean age of 41 years (range 28-59) were included in the study. At least eight samples of sweat were collected from each individual by pilocarpine iontophoresis. Chloride and sodium concentrations were measured in duplicate for each sample using ion selective electrodes. After the removal of outliers, the CV A , CV I , and CV G of chloride and sodium were determined, and their impact on measurement uncertainty and reference change value were calculated. The CV A , CV I , and CV G of chloride in sweat samples were 6.5, 17.7, and 47.2%, respectively. The CV A , CV I , and CV G of sodium sweat samples were 6.0, 17.5, and 42.6%, respectively. Our study indicates that sweat chloride and sodium concentration results must be interpreted with great care. Different components of variation, particularly the biological variations, have a considerable impact on the interpretation of these results. If no pre-analytical, analytical, or post-analytical errors are suspected, repeated sweat testing to confirm first-measurement results might not be desirable.

  7. Diagnosis of cystic fibrosis with chloride meter (Sherwood M926S chloride analyzer®) and sweat test analysis system (CFΔ collection system®) compared to the Gibson Cooke method.

    Science.gov (United States)

    Emiralioğlu, Nagehan; Özçelik, Uğur; Yalçın, Ebru; Doğru, Deniz; Kiper, Nural

    2016-01-01

    Sweat test with Gibson Cooke (GC) method is the diagnostic gold standard for cystic fibrosis (CF). Recently, alternative methods have been introduced to simplify both the collection and analysis of sweat samples. Our aim was to compare sweat chloride values obtained by GC method with other sweat test methods in patients diagnosed with CF and whose CF diagnosis had been ruled out. We wanted to determine if the other sweat test methods could reliably identify patients with CF and differentiate them from healthy subjects. Chloride concentration was measured with GC method, chloride meter and sweat test analysis system; also conductivity was determined with sweat test analysis system. Forty eight patients with CF and 82 patients without CF underwent the sweat test, showing median sweat chloride values 98.9 mEq/L with GC method, 101 mmol/L with chloride meter, 87.8 mmol/L with sweat test analysis system. In non-CF group, median sweat chloride values were 16.8 mEq/L with GC method, 10.5 mmol/L with chloride meter, and 15.6 mmol/L with sweat test analysis system. Median conductivity value was 107.3 mmol/L in CF group and 32.1 mmol/L in non CF group. There was a strong positive correlation between GC method and the other sweat test methods with a statistical significance (r=0.85) in all subjects. Sweat chloride concentration and conductivity by other sweat test methods highly correlate with the GC method. We think that the other sweat test equipments can be used as reliably as the classic GC method to diagnose or exclude CF.

  8. Sweating the small stuff: adequacy and accuracy in sweat chloride determination.

    Science.gov (United States)

    DeMarco, Mari L; Dietzen, Dennis J; Brown, Sarah M

    2015-04-01

    Sweat chloride testing is the gold standard for diagnosis of cystic fibrosis (CF). Our objectives were to: 1) describe variables that determine sweat rate; 2) determine the analytic and diagnostic capacity of sweat chloride analysis across the range of observed sweat rates; and 3) determine the biologic variability of sweat chloride concentration. A retrospective analysis was performed using data from all sweat chloride tests performed at St. Louis Children's Hospital over a 21-month period. A total of 1397 sweat chloride tests (1155 sufficient [≥75 mg], 242 insufficient [sweat weight collected from forearms was statistically greater than that collected from legs. There was a negligible correlation between sweat weight and chloride concentration (r=-0.06). The mean individual biologic CV calculated from individuals with two or more sweat collections ≥75 mg was 13.1% (95% CI: 11.3-14.9%; range 0-88%) yielding a reference change value of 36%. Using 60 mmol/L as the diagnostic chloride cutoff, 100% of CF cases were detected whether a minimum sweat weight of 75, 40, or 20 mg was required. 1) Collection of sweat from forearms is preferable to upper legs, particularly in very young infants; 2) sweat chloride concentrations are not highly dependent upon sweat rate; 3) a change in sweat chloride concentration exceeding 36% may be considered a clinically significant response to cystic fibrosis transmembrane receptor targeted therapy, and 4) sweat collections of less than 75 mg provide clinically accurate information. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

    Science.gov (United States)

    Gomez, Carla Cristina Souza; Servidoni, Maria de Fatima; Marson, Fernando Augusto de Lima; Canavezi, Paulo Jose Coelho; Vinagre, Adriana Mendes; Costa, Eduardo Tavares; Ribeiro, Antonio Fernando; Ribeiro, Maria Angela Gonçalves de Oliveira; Toro, Adyleia Aparecida Dalbo Contrera; Pavan, Celia Regina; Rondon, Michelle Vivine Sá Dos Santos; Lorena, Sonia Leticia Silva; Vieria, Francisco Ubaldi; Ribeiro, Jose Dirceu

    2014-12-13

    The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.

  10. Effects of Immediate Telephone Follow-Up with Providers on Sweat Chloride Test Timing after Cystic Fibrosis Newborn Screening Identifies a Single Mutation

    Science.gov (United States)

    La Pean, Alison; Farrell, Michael H.; Eskra, Kerry L.; Farrell, Philip M.

    2012-01-01

    Objectives To assess whether reporting “possible cystic fibrosis (CF)” newborn screening (NBS) results via fax plus simultaneous telephone contact with primary care providers (PCPs), versus fax alone, influenced three outcomes: getting a sweat chloride test, age at sweat chloride test, and sweat-testing before 8 weeks old. Study Design Retrospective cohort comparison of infants born in Wisconsin whose PCPs received telephone intervention (n=301), versus recent historical controls whose PCP did not (n=355). Intervention data were collected during a longitudinal research and quality improvement effort; de-identified comparison data were constructed from auxiliary NBS tracking information. Parametric and nonparametric statistical analyses tested for group differences. Results Most infants (92%) with “possible CF” NBS results whose PCPs lacked telephone intervention ultimately underwent sweat-testing, underlining efficacy for fax-only reporting. Telephone intervention was significantly associated with improvements in infants undergoing sweat-testing at both ≤6 and sweat-testing. The effect of telephone intervention was greater for PCPs whose patients underwent sweat-testing at community-affiliated medical centers versus academic medical centers (p=0.008). Conclusion Reporting “possible CF” NBS results via fax plus simultaneous telephone follow-up with PCPs increases the number of infants who have sweat chloride tests before 8 weeks of age, when affected infants are more likely to receive full benefits of early diagnosis and treatment. PMID:23102590

  11. Sweat chloride concentrations in children with Idiopathic Nephrotic Syndrome.

    Science.gov (United States)

    Guglani, Lokesh; Moir, Devin; Jain, Amrish

    2016-01-01

    Idiopathic Nephrotic Syndrome (INS) has been believed to cause a false positive elevation of sweat chloride concentrations, as measured by the sweat test. Sweat tests were done for 11 children with acute onset INS at admission and again while they were in remission, with results being compared to normal historical controls. The initial sweat chloride concentration for 10 patients was normal (mean16.7 ± 11.02 mmol/L) and 1 patient had inadequate collection. This latter patient and two others were excluded during follow-up because of diagnoses other than INS. Sweat test results for the eight INS patients during follow up remained unchanged when they were in remission (16.94 ± 7.88 mmol/L; P = 0.98; Wilcoxon Matched-Pairs Signed Rank Test). In comparing sweat chloride concentrations from INS patients to those from 20 historical control subjects, we found no significant differences (Mann-Whitney Test; initial vs. control P = 0.643; follow up vs. control P = 0.806). INS does not cause a false positive sweat test. Further studies should be done to objectively assess the conditions that have been reported to affect sweat chloride concentrations. © 2015 Wiley Periodicals, Inc.

  12. Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.

    Science.gov (United States)

    Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A

    2014-03-01

    We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.

  13. Cystic fibrosis with normal sweat chloride concentration: case report

    Directory of Open Access Journals (Sweden)

    Silva Filho Luiz Vicente Ferreira da

    2003-01-01

    Full Text Available Cystic fibrosis is a genetic disease usually diagnosed by abnormal sweat testing. We report a case of an 18-year-old female with bronchiectasis, chronic P. aeruginosa infection, and normal sweat chloride concentrations who experienced rapid decrease of lung function and clinical deterioration despite treatment. Given the high suspicion ofcystic fibrosis, broad genotyping testing was performed, showing a compound heterozygous with deltaF508 and 3849+10kb C->T mutations, therefore confirming cystic fibrosis diagnosis. Although the sweat chloride test remains the gold standard for the diagnosis of cystic fibrosis, alternative diagnostic tests such as genotyping and electrophysiologic measurements must be performed if there is suspicion of cystic fibrosis, despite normal or borderline sweat chloride levels.

  14. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis

    Science.gov (United States)

    Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.

    2016-01-01

    Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker

  15. A new method of sweat testing: the CF Quantum®sweat test.

    Science.gov (United States)

    Rock, Michael J; Makholm, Linda; Eickhoff, Jens

    2014-09-01

    Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  16. Sweat conductivity: an accurate diagnostic test for cystic fibrosis?

    Science.gov (United States)

    Mattar, Ana Claudia Veras; Leone, Claudio; Rodrigues, Joaquim Carlos; Adde, Fabíola Villac

    2014-09-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. Sweat conductivity is widely used although still considered a screening test. This was a prospective, cross-sectional, diagnostic research conducted at the laboratory of the Instituto da Criança of the Hospital das Clínicas, São Paulo, Brazil. Sweat chloride (quantitative pilocarpine iontophoresis) and sweat conductivity tests were simultaneously performed in patients referred for a sweat test between March 2007 and October 2008. Conductivity and chloride cut-off values used to rule out or diagnose CF were sweat chloride and conductivity values were 11 and 25 mmol/L in these populations, respectively. Twenty-four patients who had received a diagnosis of CF presented median sweat chloride and conductivity values of 87 and 103 mmol/L, respectively. Conductivity values above 90 mmol/L had 83.3% sensitivity, 99.7% specificity, 90.9% PPV and 99.4% NPV to diagnose CF. The best conductivity cut-off value to exclude CF was sweat conductivity test yielded a high degree of diagnostic accuracy and it showed good agreement with sweat chloride. We suggest that it should play a role as a diagnostic test for CF in the near future. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  17. Relationship between sweat chloride, sodium, and age in clinically obtained samples.

    Science.gov (United States)

    Traeger, Nadav; Shi, Qiuhu; Dozor, Allen J

    2014-01-01

    The relationship between sweat electrolytes and age is uncertain, as is the value of measuring sodium or the chloride:sodium ratio. 13,785 sweat tests performed over 23 years at one center through the Macroduct collection in clinically obtained samples were analyzed. Sweat chloride tended to decrease over the first year of life, slowly increase until the fourth decade, then either level off or slightly decrease. In children, sweat sodium overlapped between those with positive and negative sweat tests, but not in adults. If the sweat test was positive, there was a higher likelihood of having a chloride:sodium ratio >1, but most subjects with a ratio >1 did not have CF. Sweat chloride and sodium vary with age. Measurement of sweat sodium did not add discriminatory value. The proportion of subjects with a chloride:sodium ratio >1, with or without CF, varied greatly between age ranges. © 2013. Published by Elsevier B.V. on behalf of European Cystic Fibrosis Society. All rights reserved.

  18. Ninhydrin sweat test in leprosy.

    Science.gov (United States)

    Markendeya, N; Srinivas, C R

    2004-01-01

    Loss of sensation is an important feature of leprosy. Loss of sweating over the affected site due to loss of autonomic function occurs in leprosy. We have studied a simple, non-invasive, rapid method, using 1% ninhydrin in acetone, to detect loss of sweat function. The test was effective in detecting and grading the sweat function in 84 cases of different types of leprosy. We were able to detect normal sweating in 16 patients with hypopigmented lesion due to causes other than Hansen's disease.

  19. Comparison of Quantitative Sweat Chloride Methods after Positive Newborn Screen for Cystic Fibrosis

    Science.gov (United States)

    Laguna, Theresa A.; Lin, Nan; Wang, Qi; Holme, Bonnie; McNamara, John; Regelmann, Warren E.

    2013-01-01

    Summary Objectives Rapid and reliable confirmatory sweat testing following a positive newborn screen (NBS) for cystic fibrosis (CF) is preferred to allow for early diagnosis and to decrease parental anxiety. The Cystic Fibrosis Foundation (CFF) recently recommended a quantity not sufficient (QNS) rate of ≤ 10% in infants sweat chloride analysis. Two CFF-approved methods are available by which to quantitatively measure chloride concentration in sweat. Our objective was to compare the performance of the Macroduct® sweat collection system (MSCS) with the Gibson and Cooke technique (GCT) in the acquisition of samples for the determination of sweat chloride concentration in infants with a positive Minnesota State NBS for cystic fibrosis. Methods A retrospective database review of infants referred to the core Minnesota CF Center or its affiliate site for confirmatory sweat testing was performed to compare the QNS rates for the two techniques. Associations between birthweight, age at test, race and QNS rates were examined. Results 568 infants were referred for 616 sweat tests from March 2006–January 2010. The mean age was 32.8 days at the initial sweat test. The GCT had a significantly higher QNS rate compared to the MSCS (15.4% vs. 2.1%, psweat testing in infants following a positive state NBS. PMID:22786625

  20. Higher sweat chloride levels in patients with asthma: a case-control study.

    Science.gov (United States)

    Awasthi, Shally; Dixit, Pratibha; Maurya, Nutan

    2015-02-01

    To screen asthmatic patients by sweat chloride test to identify proportion with Cystic Fibrosis (CF); (Sweat chloride level >60 mmol/L). Also, to compare sweat chloride levels between cases of bronchial asthma and age and sex matched healthy children aged 5 mo-15 y. The present case-control study was conducted in a tertiary care hospital in India. Cases of bronchial asthma, diagnosed by GINA guideline 2008, and age matched healthy controls were included. Case to control ratio was 2:1. Sweat Chloride test was done by Pilocarpine Iontophoresis method. From April 2010 through May 2012, 216 asthmatics and 112 controls were recruited. Among asthmatics, there was no case of Cystic Fibrosis. Mean sweat chloride levels in asthmatics was 22.39 ± 8.45 mmol/L (inter-quartile range - 15-28 mmol/L) and in controls 19.55 ± 7.04 mmol/L (inter-quartile range - 15-23.5 mmol/L) (p value = 0.048). No Cystic Fibrosis case was identified among asthmatics. Mean sweat chloride levels were higher in asthmatics as compared to controls.

  1. Chloride Test

    Science.gov (United States)

    ... and bicarbonate , to help regulate the amount of fluid in the body and maintain the acid-base balance . This test measures the level of chloride in ... and bicarbonate , to help regulate the amount of fluid in the body and maintain the acid-base (pH) balance . Chloride and electrolyte tests may also be ordered ...

  2. Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations.

    Science.gov (United States)

    Vermeulen, F; Le Camus, C; Davies, J C; Bilton, D; Milenković, D; De Boeck, K

    2017-01-01

    Sweat chloride concentration, a biomarker of CFTR function, is an appropriate outcome parameter in clinical trials aimed at correcting the basic CF defect. Although there is consensus on a cut-off value to diagnose CF, we have only limited information on the within subject variability of sweat chloride over time. Such information would be useful for sample size calculations in clinical trials. Therefore, we retrospectively analyzed repeated sweat chloride values obtained in patients with G551D mutation(s) assigned to placebo in an ivacaftor interventional trial. In subjects with G551D at least 12years of age, a pilocarpine sweat test using Macroduct collector was taken on both arms at 8 time points over 48weeks. We explored 1062 pilocarpine sweat test values obtained in 78 placebo patients of the VX08-770-102 trial. Mean overall sweat chloride value (all patients, all tests, n=1062) was 100.8mmol/L (SD 12.7mmol/L). Using a multilevel mixed model, the between-subject standard deviation (SD) for sweat chloride was 8.9mmol/L (95% CI 7.4-10.6) and within-subject SD was 8.1mmol/L (95% CI 7.5-8.7). Limits of repeatability for repeat measurements were -19.7 to +21.6mmol/L using values from one arm, and -13.3 to 11.8mmol/L using mean of values obtained at 4 test occasions. Sample size calculations showed that the minimal treatment effect on sweat chloride concentration that can be demonstrated for a group of 5 patients is around 15mmol/L, using a cross-over design and combinations of 4 tests for each phase of the trial. Although the sweat test is considered a robust measure, sweat chloride measurements in patients with CF and a G551D mutation had an inherent biological variability that is higher than commonly considered. Further analyses of placebo group data are crucial to learn more about the natural variability of this outcome parameter. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  3. [Sweat chloride measurement using direct potentiometry: Spotchem(®) (Elitech-Arkray) evaluation and comparison with coulometry and conductivity].

    Science.gov (United States)

    Nguyen-Khoa, Thao; Borgard, Jean-Pierre; Miled, Ryad; Rota, Michèle

    2013-01-01

    Sweat chloride (Cl(-)) measurement is a key step for the diagnosis of cystic fibrosis. The coulometric technique is validated in this context by international guidelines. The aim of our study was to evaluate the assay for sweat Cl(-) ions using direct potentiometry on disposable cassette (Spotchem™ SE EL-1520, Elitech-Arkray) by comparing results to those obtained on the same sample, by coulometry (Chloride analyser Sherwood 926S, Dutscher). To complete our table of correspondence between the results of Cl(-) ions and sweat conductivity (Sweat Check™ 3100), conductivity has been also achieved for 99 of the 139 sweat samples studied. Linearity of each technique performed extends from 10 to 120 mmol/L. The coefficients of variation within and between runs are Sweat Cl(-) determinations using Spotchem™ analyser meet the criteria required by analytical recommendations. The technique is standardized, easy to perform and fast. Its good practicability makes the sweat test independent to operator and allows point-of care use.

  4. Transient elevation of sweat chloride concentration in a malnourished girl with the Mauriac syndrome.

    Science.gov (United States)

    Polack, F P; Transue, D J; Belknap, W M; Freij, B J; Aughton, D J

    1995-02-01

    Elevated sweat chloride concentration in a patient with Mauriac syndrome has been reported only once. The authors of that report regarded their patient's underlying malnutrition, and not Mauriac syndrome per se, as the cause of the elevated sweat chloride concentration. We describe a second example of transient elevation of sweat chloride concentration, which confirms that the malnutrition intrinsic to Mauriac syndrome, rather than the syndrome itself, was the probable cause of elevated sweat chloride values.

  5. Lack of harmonization in sweat testing for cystic fibrosis

    DEFF Research Database (Denmark)

    Lindegaard Christiansen, Anne; Nybo, Mads

    2014-01-01

    Abstract Introduction. Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study...... fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use....... a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. Conclusion. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic...

  6. Sweating

    Science.gov (United States)

    ... Home Body Looking and feeling your best Sweating Sweating You might think that you are only supposed to sweat when you are hot, but once you hit puberty, you will also sweat when you are nervous. Your sweat glands, which ...

  7. Chloride Blood Test

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the amount of ...

  8. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  9. Sweat

    Science.gov (United States)

    Sweat is a clear, salty liquid produced by glands in your skin. Sweating is how your body cools itself. You sweat mainly under your arms and on your feet and palms. When sweat mixes with bacteria on your skin, it can ...

  10. Chloride Test

    Science.gov (United States)

    ... Sex Hormone Binding Globulin (SHBG) Shiga toxin-producing Escherichia coli Sickle Cell Tests Sirolimus Smooth Muscle Antibody (SMA) ... 20Files/Nutrition/DRIs/DRI_Electrolytes_Water.pdf?la=en. Accessed Oct 2015. Sources Used in Previous Reviews ...

  11. Correlation of sweat chloride and percent predicted FEV1in cystic fibrosis patients treated with ivacaftor.

    Science.gov (United States)

    Fidler, Meredith C; Beusmans, Jack; Panorchan, Paul; Van Goor, Fredrick

    2017-01-01

    Ivacaftor, a CFTR potentiator that enhances chloride transport by acting directly on CFTR to increase its channel gating activity, has been evaluated in patients with different CFTR mutations. Several previous analyses have reported no statistical correlation between change from baseline in ppFEV 1 and reduction in sweat chloride levels for individuals treated with ivacaftor. The objective of the post hoc analysis described here was to expand upon previous analyses and evaluate the correlation between sweat chloride levels and absolute ppFEV 1 changes across multiple cohorts of patients with different CF-causing mutations who were treated with ivacaftor. The goal of the analysis was to help define the potential value of sweat chloride as a pharmacodynamic biomarker for use in CFTR modulator trials. For any given study, reductions in sweat chloride levels and improvements in absolute ppFEV 1 were not correlated for individual patients. However, when the data from all studies were combined, a statistically significant correlation between sweat chloride levels and ppFEV 1 changes was observed (psweat chloride level changes in response to potentiation of the CFTR protein by ivacaftor appear to be a predictive pharmacodynamic biomarker of lung function changes on a population basis but are unsuitable for the prediction of treatment benefits for individuals. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Chloride and potassium conductances of cultured human sweat ducts

    DEFF Research Database (Denmark)

    Novak, I; Pedersen, P S; Larsen, Erik Hviid

    1992-01-01

    The purpose of this study was to characterize the ion conductances, in particular those for Cl- and K+, of human sweat duct cells grown in primary culture. Sweat duct cells from healthy individuals were grown to confluence on a dialysis membrane, which was then mounted in a mini-Ussing chamber...

  13. Association of sweat chloride concentration at time of diagnosis and CFTR genotype with mortality and cystic fibrosis phenotype.

    Science.gov (United States)

    McKone, Edward F; Velentgas, Priscilla; Swenson, Anna J; Goss, Christopher H

    2015-09-01

    The extent to which sweat chloride concentration predicts survival and clinical phenotype independently of CFTR genotype in cystic fibrosis is not well understood. We analyzed the US Cystic Fibrosis Foundation Patient Registry data using Cox regression to examine the relationship between sweat chloride concentration (sweat chloride, CFTR genotype, and measures of lung function and growth. When included in the same model, CFTR genotype, but not sweat chloride, was independently associated with survival and with lung function, height, and BMI. Among patients with unclassified CFTR genotype, sweat chloride was an independent predictor of survival (Sweat chloride concentration may be a useful predictor of mortality and clinical phenotype when CFTR genotype functional class is unclassified. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  14. Long-term outcomes of children with intermediate sweat chloride values in infancy.

    Science.gov (United States)

    Groves, Tyler; Robinson, Paul; Wiley, Veronica; Fitzgerald, Dominic A

    2015-06-01

    To describe the clinical course of children who have intermediate sweat chloride values on initial screening for cystic fibrosis (CF). We performed a retrospective review of children with intermediate sweat chloride values (raised immunoreactive trypsinogen/1 copy of p.F508del CF mutation on newborn screening (NBS)/sweat chloride value of 30-59 mmol/L) presenting to The Children's Hospital at Westmead over 15 years. Patients with an intermediate sweat chloride evolving to a formal diagnosis of CF (termed "delayed CF") were matched (2:1) with NBS positive patients with CF (termed "NBS positive CF"). Clinical outcomes were compared. Fourteen of 29 (48%, 95% CI 0.3-0.66) patients with intermediate sweat chloride value evolved to a diagnosis of CF and were matched with 28 NBS positive patients with CF. Delayed CF had less pancreatic insufficiency (OR 0.06, 95% CI 0.01-0.44, P = .006), less colonization with nonmucoid Pseudomonas aeruginosa (OR 0.04, 95% CI 0.01-0.38, P = .005), milder obstructive lung disease (forced expiratory volume in 1 second/forced vital capacity ratio), and overall disease severity (Shwachman scores) at 10 years (mean difference 5.93, 95% CI 0.39-11.46, P = .04; mean difference 4.72, 95% CI 0.9-8.53, P = .015, respectively). Nutritional outcomes were better at 2 years for delayed CF but did not persist to later ages. In this cohort, approximately one-half of infants with intermediate sweat chloride value were later diagnosed with CF. The clinical course of delayed CF was milder in some aspects compared with NBS positive CF. These results emphasize the importance of ongoing follow-up of infants with intermediate sweat chloride values. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  15. Lack of harmonization in sweat testing for cystic fibrosis - a national survey.

    Science.gov (United States)

    Christiansen, Anne Lindegaard; Nybo, Mads

    2014-11-01

    Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study was to investigate how performance of the test is organized in Denmark. Departments conducting the sweat test were contacted and interviewed following a premade questionnaire. They were asked about methods performed, applied NPU (Nomenclature for Properties and Units) code, reference interval, recommended interpretation and referred literature. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use.

  16. Sweating

    Science.gov (United States)

    ... treat mental disorders Menopause Spicy foods (known as "gustatory sweating") Warm temperatures Withdrawal from alcohol or narcotic ... D, Chelimsky G. Disorders of the autonomic nervous system. In: Daroff RB, Fenichel GM, Jankovic J, Mazziotta ...

  17. Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.

    Science.gov (United States)

    Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F

    2014-02-01

    The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.

  18. Store-operated Ca2+ entry regulates Ca2+-activated chloride channels and eccrine sweat gland function.

    Science.gov (United States)

    Concepcion, Axel R; Vaeth, Martin; Wagner, Larry E; Eckstein, Miriam; Hecht, Lee; Yang, Jun; Crottes, David; Seidl, Maximilian; Shin, Hyosup P; Weidinger, Carl; Cameron, Scott; Turvey, Stuart E; Issekutz, Thomas; Meyts, Isabelle; Lacruz, Rodrigo S; Cuk, Mario; Yule, David I; Feske, Stefan

    2016-11-01

    Eccrine sweat glands are essential for sweating and thermoregulation in humans. Loss-of-function mutations in the Ca2+ release-activated Ca2+ (CRAC) channel genes ORAI1 and STIM1 abolish store-operated Ca2+ entry (SOCE), and patients with these CRAC channel mutations suffer from anhidrosis and hyperthermia at high ambient temperatures. Here we have shown that CRAC channel-deficient patients and mice with ectodermal tissue-specific deletion of Orai1 (Orai1K14Cre) or Stim1 and Stim2 (Stim1/2K14Cre) failed to sweat despite normal sweat gland development. SOCE was absent in agonist-stimulated sweat glands from Orai1K14Cre and Stim1/2K14Cre mice and human sweat gland cells lacking ORAI1 or STIM1 expression. In Orai1K14Cre mice, abolishment of SOCE was associated with impaired chloride secretion by primary murine sweat glands. In human sweat gland cells, SOCE mediated by ORAI1 was necessary for agonist-induced chloride secretion and activation of the Ca2+-activated chloride channel (CaCC) anoctamin 1 (ANO1, also known as TMEM16A). By contrast, expression of TMEM16A, the water channel aquaporin 5 (AQP5), and other regulators of sweat gland function was normal in the absence of SOCE. Our findings demonstrate that Ca2+ influx via store-operated CRAC channels is essential for CaCC activation, chloride secretion, and sweat production in humans and mice.

  19. Quantification of sweat gland volume and innervation in neuropathy: Correlation with thermoregulatory sweat testing.

    Science.gov (United States)

    Loavenbruck, Adam; Wendelschaefer-Crabbe, Gwen; Sandroni, Paola; Kennedy, William R

    2014-10-01

    No study has correlated thermoregulatory sweat testing (TST) with histopathologic study of sweat glands (SGs) and SG nerve fibers (SGNFs). We studied 10 neuropathy patients in whom anhidrosis was found by TST and 10 matched controls. Skin biopsies were taken from both anhidrotic and sweating skin and immunohistochemical staining was done for nerves and basement membrane. For each biopsy, total tissue volume, total SG volume, and total SGNF length were measured. SGNF length per biopsy volume, SG volume per biopsy volume (SG%), and SGNF length per SG volume were calculated. SGNF length per biopsy volume was reduced in anhidrotic site biopsies of patients compared with controls. SG% was decreased and SGNF length per SG volume increased in patients compared with controls. The results suggest a concomitant loss of SG volume and SGNF length in neuropathy, with greater loss of SGNFs in anhidrotic skin, possibly exceeding collateral reinnervation. Copyright © 2014 Wiley Periodicals, Inc.

  20. The Italian pilot external quality assessment program for cystic fibrosis sweat test.

    Science.gov (United States)

    Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; Carta, Claudio; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Capoluongo, Ettore; Caruso, Ubaldo; Castaldo, Giuseppe; Cirilli, Natalia; Corbetta, Carlo; Padoan, Rita; Raia, Valeria; Taruscio, Domenica

    2016-05-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). Ten laboratories, included among the 33 Italian CF Referral Centers, were selected and enrolled on the basis of their attitude to perform sweat test (ST) analysis by using methods recommended by the Italian Guidelines. They received three different sweat-like samples (normal, borderline and pathologic chloride concentration), with mock clinical indications, for analysis according to routine procedures. Assessment, performed by a panel of experts, covered analytical performance, interpretation and reporting of results; categories of "poor" and "satisfactory" performance were not defined. All data were managed through a web utility. The program identified important areas of interest and, in some case, of concern. It is important to underline that results are referred to a small proportion, i.e. about 30%, of Italian laboratories performing CF ST in the context of the Referral Centers. Data collected highlight the importance of participation in EQA programs as it may improve laboratory/clinical performance; our study represents a model for the setting up of a large-scale EQA scheme for ST. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Testing in artificial sweat - Is less more? Comparison of metal release in two different artificial sweat solutions.

    Science.gov (United States)

    Midander, Klara; Julander, Anneli; Kettelarij, Jolinde; Lidén, Carola

    2016-11-01

    Metal release from materials immersed in artificial sweat can function as a measure of potential skin exposure. Several artificial sweat models exist that, to various degree, mimic realistic conditions. Study objective was to evaluate metal release from previously examined and well characterized materials in two different artificial sweat solutions; a comprehensive sweat model intended for use within research, based on the composition of human sweat; and the artificial sweat, EN1811, intended for testing compliance with the nickel restriction in REACH. The aim was to better understand whether there are advantages using either of the sweat solutions in bio-elution testing of materials. Metal release in two different artificial sweat solutions was compared for discs of a white gold alloy and two hard metals, and a rock drilling insert of tungsten carbide at 1 h, 24 h, 1 week and 1 month. The released amount of metal was analysed by means of inductively coupled plasma mass spectrometry. Similar levels of released metals were measured from test materials in the two different artificial sweat solutions. For purposes in relation to legislations, it was concluded that a metal release test using a simple artificial sweat composition may provide results that sufficiently indicate the degree of metal release at skin contact. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Effect of salt supplementation on the rate of inadequate sweat collection for infants less than 3 months of age referred for the sweat test.

    Science.gov (United States)

    Guglani, Lokesh; Abdulhamid, Ibrahim

    2015-01-01

    Sweat testing in young infants (≤ 3 months) with a positive newborn screen for Cystic Fibrosis (CF) can yield higher rates of inadequate sweat collection. The role of salt supplements in improving sweat collection has not been studied before. All young infants referred to our CF center for sweat testing were randomized to either receive salt supplements {1/8th teaspoon salt (750 mg)} mixed in formula feeds 1 day prior to sweat testing (study group) or no salt supplement (controls). Of the 151 young infants that underwent sweat testing over 18 months, 75 received salt supplements, while 76 did not. A total of 9 (11.8%) infants in the salt supplement group had inadequate sweat collection, as compared to 4 (5.2%) infants in the control group (p = 0.16, Fisher's Exact Test). Oral salt supplementation for young infants prior to sweat testing does not help to reduce the rates of inadequate sweat collection.

  3. Ion chromatography for the precise analysis of chloride and sodium in sweat for the diagnosis of cystic fibrosis

    NARCIS (Netherlands)

    Doorn, J.; Storteboom, T. T. R.; Mulder, A. M.; de Jong, W. H. A.; Rottier, B. L.; Kema, I. P.

    BACKGROUND: Measurement of chloride in sweat is an essential part of the diagnostic algorithm for cystic fibrosis. The lack in sensitivity and reproducibility of current methods led us to develop an ion chromatography/high-performance liquid chromatography (IC/HPLC) method, suitable for the analysis

  4. Loss of carbonic anhydrase XII function in individuals with elevated sweat chloride concentration and pulmonary airway disease.

    Science.gov (United States)

    Lee, Melissa; Vecchio-Pagán, Briana; Sharma, Neeraj; Waheed, Abdul; Li, Xiaopeng; Raraigh, Karen S; Robbins, Sarah; Han, Sangwoo T; Franca, Arianna L; Pellicore, Matthew J; Evans, Taylor A; Arcara, Kristin M; Nguyen, Hien; Luan, Shan; Belchis, Deborah; Hertecant, Jozef; Zabner, Joseph; Sly, William S; Cutting, Garry R

    2016-05-15

    Elevated sweat chloride levels, failure to thrive (FTT), and lung disease are characteristic features of cystic fibrosis (CF, OMIM #219700). Here we describe variants in CA12 encoding carbonic anhydrase XII in two pedigrees exhibiting CF-like phenotypes. Exome sequencing of a white American adult diagnosed with CF due to elevated sweat chloride, recurrent hyponatremia, infantile FTT and lung disease identified deleterious variants in each CA12 gene: c.908-1 G>A in a splice acceptor and a novel frameshift insertion c.859_860insACCT. In an unrelated consanguineous Omani family, two children with elevated sweat chloride, infantile FTT, and recurrent hyponatremia were homozygous for a novel missense variant (p.His121Gln). Deleterious CFTR variants were absent in both pedigrees. CA XII protein was localized apically in human bronchiolar epithelia and basolaterally in the reabsorptive duct of human sweat glands. Respiratory epithelial cell RNA from the adult proband revealed only aberrant CA12 transcripts and in vitro analysis showed greatly reduced CA XII protein. Studies of ion transport across respiratory epithelial cells in vivo and in culture revealed intact CFTR-mediated chloride transport in the adult proband. CA XII protein bearing either p.His121Gln or a previously identified p.Glu143Lys missense variant localized to the basolateral membranes of polarized Madin-Darby canine kidney (MDCK) cells, but enzyme activity was severely diminished when assayed at physiologic concentrations of extracellular chloride. Our findings indicate that loss of CA XII function should be considered in individuals without CFTR mutations who exhibit CF-like features in the sweat gland and lung. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. CHLORIDE WASHER PERFORMACE TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J; David Best, D; Robert Pierce, R

    2007-11-30

    Testing was performed to determine the chloride (Cl-) removal capabilities of the Savannah River National Laboratory (SRNL) designed and built Cl- washing equipment intended for HB-Line installation. The equipment to be deployed was tested using a cerium oxide (CeO2) based simulant in place of the 3013 plutonium oxide (PuO2) material. Two different simulant mixtures were included in this testing -- one having higher Cl- content than the other. The higher Cl- simulant was based on K-Area Interim Surveillance Inspection Program (KIS) material with Cl- content approximately equal to 70,000 ppm. The lower Cl- level simulant was comparable to KIS material containing approximately 8,000-ppm Cl- content. The performance testing results indicate that the washer is capable of reducing the Cl- content of both surrogates to below 200 ppm with three 1/2-liter washes of 0.1M sodium hydroxide (NaOH) solution. Larger wash volumes were used with similar results - all of the prescribed test parameters consistently reduced the Cl- content of the surrogate to a value below 200 ppm Cl- in the final washed surrogate material. The washer uses a 20-micron filter to retain the surrogate solids. Tests showed that 0.16-0.41% of the insoluble fraction of the starting mass passed through the 20-micron filter. The solids retention performance indicates that the fissile masses passing through the 20-micron filter should not exceed the waste acceptance criteria for discard in grout to TRU waste. It is recommended that additional testing be pursued for further verification and optimization purposes. It is likely that wash volumes smaller than those tested could still reduce the Cl- values to acceptable levels. Along with reduced wash volumes, reuse of the third wash volume (in the next run processed) should be tested as a wash solution minimization plan. A 67% reduction in the number of grouted paint pails could be realized if wash solution minimization testing returned acceptable results.

  6. A novel TMEM16A splice variant lacking the dimerization domain contributes to calcium-activated chloride secretion in human sweat gland epithelial cells.

    Science.gov (United States)

    Ertongur-Fauth, Torsten; Hochheimer, Andreas; Buescher, Joerg Martin; Rapprich, Stefan; Krohn, Michael

    2014-11-01

    Sweating is an important physiological process to regulate body temperature in humans, and various disorders are associated with dysregulated sweat formation. Primary sweat secretion in human eccrine sweat glands involves Ca(2+) -activated Cl(-) channels (CaCC). Recently, members of the TMEM16 family were identified as CaCCs in various secretory epithelia; however, their molecular identity in sweat glands remained elusive. Here, we investigated the function of TMEM16A in sweat glands. Gene expression analysis revealed that TMEM16A is expressed in human NCL-SG3 sweat gland cells as well as in isolated human eccrine sweat gland biopsy samples. Sweat gland cells express several previously described TMEM16A splice variants, as well as one novel splice variant, TMEM16A(acΔe3) lacking the TMEM16A-dimerization domain. Chloride flux assays using halide-sensitive YFP revealed that TMEM16A is functionally involved in Ca(2+) -dependent Cl(-) secretion in NCL-SG3 cells. Recombinant expression in NCL-SG3 cells showed that TMEM16A(acΔe3) is forming a functional CaCC, with basal and Ca(2+) -activated Cl(-) permeability distinct from canonical TMEM16A(ac). Our results suggest that various TMEM16A isoforms contribute to sweat gland-specific Cl(-) secretion providing opportunities to develop sweat gland-specific therapeutics for treatment of sweating disorders. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    Science.gov (United States)

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  8. Teaching Students Not to Sweat the Test

    Science.gov (United States)

    Salend, Spencer J.

    2012-01-01

    Students experiencing test anxiety encounter extreme levels of stress, nervousness, and apprehension during testing that drastically hinders their ability to perform well and negatively affects their social-emotional and behavioral development, and feelings about themselves and school. A collaborative and multidimensional approach that includes…

  9. Sweat chloride and immunoreactive trypsinogen in infants carrying two CFTR mutations and not affected by cystic fibrosis.

    Science.gov (United States)

    Castellani, Carlo; Tridello, Gloria; Tamanini, Anna; Assael, Baroukh M

    2017-07-01

    Newborns with raised immunotrypsinogen levels who have non-pathological sweat chloride values and carry two cystic fibrosis transmembrane regulator (CFTR) mutations of which at least one is not acknowledged to be cystic fibrosis (CF)-causing are at risk of developing clinical manifestations consistent with CFTR-related disorders or even CF. It is not known whether newborns with similar genotypes and normal immunoreactive trypsinogen (IRT) may share the same risk. This study found that newborns with these characteristics and normal IRT have lower sweat chloride values than those with raised IRT (p=0.007). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening.

    Science.gov (United States)

    Vernooij-van Langen, Annette; Dompeling, Edward; Yntema, Jan-Bart; Arets, Bert; Tiddens, Harm; Loeber, Gerard; Dankert-Roelse, Jeannette

    2015-08-01

    After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99%. The Nanoduct sweat test system is easier to perform and less sweat is needed. The main aim of this study was to measure the success rate of the Nanoduct compared to current approved sweat test methods in a newborn population. After informed consent of the parents, newborns with a positive screening test for CF were included. The Macroduct or Gibson and Cooke and Nanoduct were performed in all infants, during the same appointment. The chloride concentration was determined by standard coulorimetry; conductivity was measured directly and converted to a NaCl molarity. One hundred eight newborns were included: 17 with CF, 7 with cystic fibrosis transmembrane regulator (CFTR)-related metabolic syndrome (CRMS), and 84 healthy children. The success rate of the Nanoduct was 93% and for the Macroduct/Gibson and Cooke 79% (McNemar, p = 0.002). The Nanoduct detected the same CF patients as the Macroduct/Gibson and Cooke; one CF patient had an equivocal result for both tests, and no patients were missed. The area under the receiver operating characteristic curve for detection of CF with the Nanoduct was 0.999, with ideal cutoff levels of 91 and 66 mmol/l, comparable to former studies. The success rate of the Nanoduct to collect sufficient sweat in infants was higher compared to the Macroduct and Gibson and Cooke.

  11. Sweat output measurement of the post-ganglion sudomotor response by Q-Sweat Test: a normative database of Chinese individuals

    Directory of Open Access Journals (Sweden)

    Chen Shu-Fang

    2012-06-01

    Full Text Available Abstract Background Q-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking. Results One hundred and fifty (150 healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot did not significantly correlate with age, gender, body height (BH, body weight (BW, and body mass index (BMI but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and  Conclusion This is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population.

  12. Sweat output measurement of the post-ganglion sudomotor response by Q-Sweat Test: a normative database of Chinese individuals

    Science.gov (United States)

    2012-01-01

    Background Q-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking. Results One hundred and fifty (150) healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot) did not significantly correlate with age, gender, body height (BH), body weight (BW), and body mass index (BMI) but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and sweat volume. Median differences at the forearm, proximal leg, distal leg, and foot were 0.538 μl, 0.744 μl, 0.695 μl, and 0.338 μl, respectively. There was an uneven distribution of male and female participants in the two BW groups. In all conditions, the total sweat volume recorded at the foot site was the smallest. Conclusion This is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population. PMID:22682097

  13. Attitudes about Advances in Sweat Patch Testing in Drug Courts: Insights from a Case Study in Southern California

    Science.gov (United States)

    Polzer, Katherine

    2010-01-01

    Drug courts are reinventing the drug testing framework by experimenting with new methods, including use of the sweat patch. The sweat patch is a band-aid like strip used to monitor drug court participants. The validity and reliability of the sweat patch as an effective testing method was examined, as well as the effectiveness, meaning how likely…

  14. Electrochemical behaviour of brass in chloride solution concentrations found in eccrine fingerprint sweat

    Energy Technology Data Exchange (ETDEWEB)

    Bond, John W., E-mail: jwb13@le.ac.uk [Department of Chemistry, George Porter Building, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Lieu, Elaine [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom)

    2014-09-15

    Highlights: • Corrosion of brass in NaCl concentrations found in eccrine sweat was investigated. • Concentrations < 0.2 M produce a layer of mainly zinc oxide after 24 h. • A concentration of 0.2 M enables active corrosion of brass at room temperature. • 0.2 M NaCl gives both zinc and copper dissolution. • 24-h immersion of brass in 0.2 M NaCl gives an oxide film thickness of 1.3 nm. - Abstract: In this work, the corrosion properties of α phase brass immersed in concentrations of aqueous NaCl solutions that are typically found in eccrine fingerprint sweat and range between 0.01 M and 0.2 M have been analysed. Analysis methods employed were electrochemical techniques, X-ray photoelectron spectroscopy and optical profiling. For NaCl concentrations <0.2 M, active corrosion did not occur although, after a period of 24 h, a passivating layer of mainly zinc oxide formed. At a concentration of 0.2 M active corrosion did occur, with measured corrosion potentials consistent with both brass and copper dissolution. A 1 h contact time at this concentration (0.2 M) resulted in the formation of a zinc oxide passivating layer with the surface ratio of zinc oxide to copper oxide increasing with time. Film thickness was calculated to be of the order of 1.3 nm after 24 h contact. Formation of oxide layers on brass by fingerprint sweat as observed here may well have implications for the successful investigation of crime by the visualisation of corrosion fingerprint ridge patterns or the reduction of hospital environmental contamination by hand contact with brass objects such as door handles or taps.

  15. Laboratory performance of sweat conductivity for the screening of cystic fibrosis.

    Science.gov (United States)

    Greaves, Ronda F; Jolly, Lisa; Massie, John; Scott, Sue; Wiley, Veronica C; Metz, Michael P; Mackay, Richard J

    2017-10-09

    There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat chloride. The aim of the study was to develop an understanding of the testing and reporting practices of sweat conductivity in Australasian laboratories. A survey specifically directed at conductivity testing was sent to the 12 laboratories registered with the Royal College of Pathologists of Australasia Quality Assurance Programs. Nine (75%) laboratories participated in the survey, seven of whom used Wescor Macroduct® for collecting sweat and the Wescor SWEAT·CHEK™ for conductivity testing, and the remaining two used the Wescor Nanoduct®. There was considerable variation in frequency and staffing for this test. Likewise, criteria about which patients it was inappropriate to test, definitions of adequate collection sweat rate, cutoffs and actions recommended on the basis of the result showed variations between laboratories. Variations in sweat conductivity testing and reporting reflect many of the same issues that were revealed in sweat chloride test audits and have the potential to lead to uncertainty about the result and the proper action in response to the result. We recommend that sweat testing guidelines should include clearer statements about the use of sweat conductivity.

  16. Feasibility and normal values of an integrated conductivity (Nanoduct™) sweat test system in healthy newborns.

    Science.gov (United States)

    Kuehni, Claudia E; Schindler, Matthias; Mazur, Agnieszka; Malzacher, Andreas; Hornung, René; Barben, Juerg

    2017-07-01

    Nanoduct™ is a simple and practical sweat analysis system measuring conductivity in situ. It requires only three microlitres of sweat, making it especially applicable to newborns. We measured conductivity in 260 healthy term infants at the age of four days, and again at four weeks to determine the proportion of successful tests, test duration, and normal values for sweat conductivity in newborns. Sufficient sweat was collected in 159/260 of four-day olds (61%), and in 225/239 of four-week olds (94%). Mean (sd) test duration was 27 (5) and 25 (5) min. Mean (sd, range) conductivity was 53mmol/l (16, 8-114) at age four days, and 36 (9, 12-64) at four weeks. Determination of sweat conductivity using Nanoduct™ cannot be recommended for four-day old newborns. However, at the age of four weeks the success rate is high (94%), and conductivity values at that age are comparable to older healthy children. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  17. Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening

    NARCIS (Netherlands)

    Vernooij-van Langen, Annette; Dompeling, Edward; Yntema, Jan-Bart; Arets, HGM|info:eu-repo/dai/nl/244205698; Tiddens, Harm; Loeber, Gerard; Dankert-Roelse, Jeannette

    After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99 %. The Nanoduct sweat test system is easier to perform and

  18. What's Sweat?

    Science.gov (United States)

    ... Weight for Me? Your Teeth Heart Murmurs What's Sweat? KidsHealth > For Kids > What's Sweat? Print A A ... dehydrated (say: dee-HI-drayt-ed). Why Does Sweat Smell? Sweat isn't just wet — it can ...

  19. Night Sweats

    Science.gov (United States)

    Symptoms Night sweats By Mayo Clinic Staff Night sweats are repeated episodes of extreme perspiration that may soak your nightclothes or ... these episodes are usually not labeled as night sweats and typically aren't a sign of a ...

  20. Concentration of electrolytes in the sweat of malnourished children.

    OpenAIRE

    Rodrigues, M. E.; M. C. MELO; Reis, F J; Penna, F J

    1994-01-01

    The sweat test was performed by the method of Gibson and Cooke on 36 children with second and third degree malnutrition, aged from 2 months to 4 years. The results were compared with those from 32 healthy, well nourished controls in the same age range. Determinations were made of sodium and chloride concentrations, chloride/sodium ratio, and the sum of the concentrations of the two electrolytes in each sample. The malnourished children were found to have higher sodium and chloride concentrati...

  1. Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration.

    Science.gov (United States)

    Vairo, Donato; Bruzzese, Laurie; Marlinge, Marion; Fuster, Lea; Adjriou, Nabil; Kipson, Nathalie; Brunet, Philippe; Cautela, Jennifer; Jammes, Yves; Mottola, Giovanna; Burtey, Stephane; Ruf, Jean; Guieu, Regis; Fenouillet, Emmanuel

    2017-09-18

    Electrolyte concentration in sweat depends on environmental context and physical condition but also on the pathophysiological status. Sweat analyzers may be therefore the future way for biological survey although how sweat electrolyte composition can reflect plasma composition remains unclear. We recruited 10 healthy subjects and 6 patients to have a broad range of plasma electrolyte concentrations (chloride, potassium and sodium) and pH. These variables were compared to those found in sweat produced following cycling exercise or pilocarpine iontophoresis, a condition compatible with operating a wearable device. We found no correlation between plasma and sweat parameters when exercise-induced sweat was analyzed, and we could identify a correlation only between plasma and sweat potassium concentration (R = 0.78, p sweat was induced using pilocarpine iontophoresis. We tested measurement repeatability in sweat at 24hr-interval for 3 days in 4 subjects and found a great intra-individual variability regarding all parameters in exercise-induced sweat whereas similar electrolyte levels were measured in pilocarpine-induced sweat. Thus, electrolyte concentration in sweat sampled following physical activity does not reflect concentration in plasma while pilocarpine iontophoresis appears to be promising to reproducibly address sweat electrolytes, and to make an indirect evaluation of plasma potassium concentration in chronic kidney disease and arrhythmia.

  2. Sweat test and cystic fibrosis: overview of test performance at public and private centers in the state of São Paulo, Brazil.

    Science.gov (United States)

    Servidoni, Maria Fátima; Gomez, Carla Cristina Souza; Marson, Fernando Augusto Lima; Toro, Adyléia Aparecida Dalbo Contrera; Ribeiro, Maria Ângela Gonçalves de Oliveira; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando

    2017-01-01

    The sweat test (ST) measures chloride levels in sweat and is considered the gold standard for the diagnosis of cystic fibrosis (CF). However, the reliability of a ST depends on their being performed by experienced technicians and in accordance with strict guidelines. Our aim was to evaluate how sweat stimulation, sweat collection, and chloride measurement are performed at 14 centers (9 public centers and 5 private centers) that routinely perform STs in the state of São Paulo, which has the highest frequency of CF in Brazil. This was a cross-sectional cohort study, using a standardized questionnaire administered in loco to the staff responsible for conducting STs. No uniformity regarding the procedures was found among the centers. Most centers were noncompliant with the international guidelines, especially regarding the collection of sweat (the samples were insufficient in 10-50% of the subjects tested); availability of stimulation equipment (which was limited at 2 centers); modernity and certification of stimulation equipment (most of the equipment having been used for 3-23 years); and written protocols (which were lacking at 12 centers). Knowledge of ST guidelines was evaluated at only 1 center. Our results show that STs largely deviate from internationally accepted guidelines at the participating centers. Therefore, there is an urgent need for standardization of STs, training of qualified personnel, and acquisition/certification of suitable equipment. These are essential conditions for a reliable diagnosis of CF, especially with the increasing demand due to newborn screening nationwide, and for the assessment of a possible clinical benefit from the use of modulator drugs. O teste do suor (TS) mede os níveis de cloro no suor e é considerado o padrão ouro para o diagnóstico da fibrose cística (FC). Contudo, a confiabilidade do TS depende de sua realização por técnicos experientes e segundo diretrizes rígidas. Nosso objetivo foi avaliar como s

  3. Equine sweat composition: effects of adrenaline infusion, exercise and training.

    Science.gov (United States)

    McConaghy, F F; Hodgson, D R; Evans, D L; Rose, R J

    1995-11-01

    Significant alterations in plasma electrolyte concentrations have been reported in horses following prolonged exercise, resulting from loss of hypertonic sweat. Sweat was collected from 10 horses undergoing a 10 week training programme; 5 at moderate intensity, to speeds of 10 m/s and 5 at low intensity, to speeds of 5 m/s. Sweat was collected from 2 sites in response to a submaximal exercise test (30 min at 50% VO2max and during an adrenaline infusion (dose mean +/- s.d.; 0.3 +/- 0.05 g/kg over 30 min). Sweat samples were analysed for sodium, chloride, potassium, protein, magnesium, calcium and urea concentrations. Sweat produced in response to exercise and adrenaline infusion was hypertonic and showed no significant differences in composition following training. However, the [NaCl] of sweat rose with increased duration of sweating. Sweat produced in response to adrenaline infusion was more dilute than that produced in response to exercise, which may be related to sympathetic outflow during exercise.

  4. Sweat Therapy.

    Science.gov (United States)

    Colmant, Stephen A.; Merta, Rod J.

    2000-01-01

    A study combined group sweating and group counseling. Four adolescent boys with disruptive behavior disorders participated in 12 sweat therapy sessions. They reported the sessions useful for sharing personal concerns and receiving assistance with problem solving. Three boys showed improvement in self-esteem. Advantages of sweat therapy over other…

  5. Accelerated testing for chloride threshold of reinforcing steel in concrete

    NARCIS (Netherlands)

    Polder, R.B.; Put, M. van; Peelen, W.H.A.

    2017-01-01

    Testing for the chloride threshold (also called critical chloride content) for corrosion initiation of steel in concrete has been found difficult and, at best, time consuming. Nevertheless, the chloride threshold is an important parameter in service life design of new structures and for evaluation

  6. A novel organotypic 3D sweat gland model with physiological functionality.

    Directory of Open Access Journals (Sweden)

    Patricia Klaka

    Full Text Available Dysregulated human eccrine sweat glands can negatively impact the quality-of-life of people suffering from disorders like hyperhidrosis. Inability of sweating can even result in serious health effects in humans affected by anhidrosis. The underlying mechanisms must be elucidated and a reliable in vitro test system for drug screening must be developed. Here we describe a novel organotypic three-dimensional (3D sweat gland model made of primary human eccrine sweat gland cells. Initial experiments revealed that eccrine sweat gland cells in a two-dimensional (2D culture lose typical physiological markers. To resemble the in vivo situation as close as possible, we applied the hanging drop cultivation technology regaining most of the markers when cultured in its natural spherical environment. To compare the organotypic 3D sweat gland model versus human sweat glands in vivo, we compared markers relevant for the eccrine sweat gland using transcriptomic and proteomic analysis. Comparing the marker profile, a high in vitro-in vivo correlation was shown. Carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5, muscarinic acetylcholine receptor M3 (CHRM3, Na+-K+-Cl- cotransporter 1 (NKCC1, calcium-activated chloride channel anoctamin-1 (ANO1/TMEM16A, and aquaporin-5 (AQP5 are found at significant expression levels in the 3D model. Moreover, cholinergic stimulation with acetylcholine or pilocarpine leads to calcium influx monitored in a calcium flux assay. Cholinergic stimulation cannot be achieved with the sweat gland cell line NCL-SG3 used as a sweat gland model system. Our results show clear benefits of the organotypic 3D sweat gland model versus 2D cultures in terms of the expression of essential eccrine sweat gland key regulators and in the physiological response to stimulation. Taken together, this novel organotypic 3D sweat gland model shows a good in vitro-in vivo correlation and is an appropriate alternative for screening of potential

  7. Ninhydrin sweat test: a simple method for detecting antibodies neutralizing botulinum toxin type A.

    Science.gov (United States)

    Voller, Bernhard; Moraru, Ekaterina; Auff, Eduard; Benesch, Michael; Poewe, Werner; Wissel, Jörg; Müller, Jörg; Entner, Tanja; Bigalke, Hans; Schnider, Peter

    2004-08-01

    Approximately 5% of patients with cervical dystonia receiving repeated botulinum neurotoxin A (BoNT/A) injections develop secondary loss of treatment benefit. Currently available tests to directly detect neutralizing BoNT/A antibodies (BoNT/A-AB) are either expensive or time consuming. To establish a simple, clinically useful test for antibody detection, we adapted the ninhydrin sweat test (NST). Eighteen dystonic patients with secondary nonresponse and clinically suspected BoNT/A-AB formation were tested for BoNT/A-AB in the mouse diaphragm test (MDT). In addition, the size of the anhidrotic area was determined by the NST 21 days after an intradermal dose of 10 U Dysport into the hypothenar region of the left palm. In nine patients, positive BoNT-AB titers were found in the MDT. There was a significant correlation between the BoNT/A-AB titers and the anhidrotic area (Spearman's rho = -0.9, P < 0.0001). Both tests provided comparably good results with respect to qualitative antibody detection. In the clinical situation of secondary nonresponse to BoNT/A therapy, the economical NST may be a helpful tool to detect neutralizing BoNT/A-AB. Copyright 2004 Movement Disorder Society

  8. Sweat Allergy.

    Science.gov (United States)

    Hiragun, Takaaki; Hide, Michihiro

    2016-01-01

    For many years, sweat has been recognized as an exacerbation factor in all age groups of atopic dermatitis (AD) and a trigger of cholinergic urticaria (CholU). Recently, we reported the improvement of AD symptoms by spray with tannic acid, which suppresses basophil histamine release by semipurified sweat antigens in vitro, and showering that removes antigens in sweat from the skin surface. We finally identified MGL_1304 secreted by Malassezia globosa as a major histamine-releasing antigen in human sweat. MGL_1304 is detected as a 17-kDa protein in sweat and exhibits almost the highest histamine-release ability from basophils of patients with AD and CholU among antigens derived from Malassezia species. Moreover, serum levels of anti-MGL_1304 IgE of patients with AD and CholU were significantly higher than those of normal controls. Desensitization therapy using autologous sweat or MGL_1304 purified from culture of M. globosa or its cognates might be beneficial for patients with intractable CholU due to sweat allergy. © 2016 S. Karger AG, Basel.

  9. Influence of digoxin and diuretic therapy on sweat fluid composition.

    Science.gov (United States)

    Mor, A; Benzon, L; Aladjem, M

    1985-01-01

    The effect of digitalis and diuretic therapy on sweat fluid composition was investigated. Patients treated for congestive heart failure with a combination of digoxin and diuretics demonstrated a higher concentration of sodium and chloride in their sweat fluid when compared to age-matched controls. The administration of diuretics alone did not affect sweat fluid composition. The digoxin-induced increase in sodium concentration was significantly higher than that observed for chloride. These data suggest that digoxin markedly inhibits sodium reabsorption along the sweat gland tubule, whereas chloride transport is affected to a lesser degree. A significant correlation between sweat fluid sodium and serum digoxin concentrations was observed. We conclude that the increased digoxin-induced sweat sodium and chloride losses may affect sodium homeostasis in patients with congestive heart failure.

  10. Composition of the secretion from the eccrine sweat glands of the cat's foot pad.

    Science.gov (United States)

    Foster, K G

    1966-05-01

    1. The sweat composition from the cat's foot pad was examined at various rates of secretion. Sodium pentobarbitone or chloralose anaesthesia were used.2. Cat's pad sweat contains lactate, glucose is almost absent, and the sodium and chloride concentrations increased with increasing sweat rate. In these respects the secretion resembles human eccrine sweat.3. The sodium, chloride, and potassium concentrations are much higher than in human sweat; also the potassium level decreased with increasing rate. Consequently, whereas human sweat is hypotonic with respect to the plasma, cat's pad sweat is slightly hypertonic with respect to the plasma even at low rates of secretion. In contrast to human sweat glands, which produce a slightly acidic secretion containing ammonia, cat's pad sweat glands produce an alkaline secretion containing bicarbonate. Also in contrast to human sweat, lactate levels decreased with increasing sweat rate.

  11. 21 CFR 862.1170 - Chloride test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis...

  12. Thermal influence on palmar sweating and mental influence on generalized sweating in man.

    Science.gov (United States)

    Ogawa, T

    1975-01-01

    Sweat rates on the forearm and on the palm were simultaneously recorded by resistance hygrometry and the mode of sweating in these areas in response to thermal and non-thermal stimuli were compared with each other. In Series A, periodic infrared irradiation (1 min on, 1 min off) was done to the back of the trunk, and reflex responses in sweat rate were recorded on both test areas. A high correlation was noted between the mean changes in the palmar sweat rate and those in the forearm one during the irradiation cycle in a majority of cases. However the magnitude of the sweat response was much less on the palm than on the forearm. These observations reveal that the central mechanism of palmar sweating may be affected to some extent by the thermoregulatory mechanism. Series B was concerned with the pattern of response in forearm sweating to various non-thermal stimuli. Careful observations showed that the forearm sweating responded diversely to various mental stimuli, unlike the palmar sweating whose response was always an increase. Mental arithmetic, mental testing and physical exercise caused an immediate increase in the palmar sweating but often elicited a transient decrease in the forearm sweating, whereas pain, noise, and emotional stimuli consistently provoked an increase of sweating on the forearm as well as on the palm. These observations suggest that the activities of higher centers, presumably involving neocortex and limbic cortex, exert various influences on the central mechanisms of palmar and generalized sweating.

  13. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability

    OpenAIRE

    Baker, Lindsay B.

    2017-01-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for a...

  14. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon

    2012-08-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  15. Sweat composition in exercise and in heat.

    Science.gov (United States)

    Verde, T; Shephard, R J; Corey, P; Moore, R

    1982-12-01

    Sweat samples were collected from the forearms of eight male volunteers using light gauze pads applied for 20-min periods. Preliminary trials indicated that this technique yielded realistic figures for both sweat volume and sweat composition. Tests were conducted under three conditions: a) outdoor exercise, cool environment; b) indoor exercise, normal room temperatures; and c) sauna exposure. In all environments, proximal forearm samples indicated a larger sweat secretion than distal forearm or hand samples. [Mg2+] decreased as sweat flow increased, but after allowance for interindividual differences of sweat volume, [Na+], [K+], [Ca2+], and [Cl-] were independent of sweat flow rates. The differential effect of sweat flow suggests active regulation rather than contamination. Interindividual differences of sweat composition could not be explained in terms of differences in personal fitness. Sauna bathing yielded sweat with a higher [Mg2+] and [Ca2+] content than did exercise; however, [Na+], [K+], and [Cl-] were similar for the three experimental conditions. Again, the data are best explained in terms of an active regulation of sweat composition. Total ionic losses do not seem sufficient to deplete body mineral reserves unless many days of training are undertaken in a hot climate.

  16. Surface resistivity test evaluation as an indicator of the chloride permeability of concrete.

    Science.gov (United States)

    2012-12-01

    Many agencies have adopted the standard tests for electrical : indication of concretes ability to resist chloride ion penetration : (AASHTO T 277 and ASTM C1202), commonly known as the rapid : chloride permeability test (RCPT), in their specificat...

  17. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study.

    Science.gov (United States)

    Kaneko, Sakae; Murota, Hiroyuki; Murata, Susumu; Katayama, Ichiro; Morita, Eishin

    2017-01-01

    Background . Sweat is an aggravating factor in atopic dermatitis (AD), regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy's involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years) to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine release tests (HRT). Furthermore, 24 of the patients received instructions on methods of sweat management, and their outcomes were evaluated on a 10-point scale. Results. Sweat HRT results were class ≥ 2 in 13 patients, but HRT results were not correlated with the patients' self-assessments of symptom aggravation by sweat. One month after receiving sweat management instructions, a low mean score of 4.6 was obtained regarding whether active sweating was good, but a high mean score of 7.0 was obtained in response to whether the sweat management instructions had been helpful. Conclusion . Our investigation showed that patients' negative impressions of sweat might derive from crude personal experiences that are typically linked to sweating. Sweat management for patients with adult atopic dermatitis was extremely useful regardless of sweat allergy.

  18. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sakae Kaneko

    2017-01-01

    Full Text Available Background. Sweat is an aggravating factor in atopic dermatitis (AD, regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy’s involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine release tests (HRT. Furthermore, 24 of the patients received instructions on methods of sweat management, and their outcomes were evaluated on a 10-point scale. Results. Sweat HRT results were class ≥ 2 in 13 patients, but HRT results were not correlated with the patients’ self-assessments of symptom aggravation by sweat. One month after receiving sweat management instructions, a low mean score of 4.6 was obtained regarding whether active sweating was good, but a high mean score of 7.0 was obtained in response to whether the sweat management instructions had been helpful. Conclusion. Our investigation showed that patients’ negative impressions of sweat might derive from crude personal experiences that are typically linked to sweating. Sweat management for patients with adult atopic dermatitis was extremely useful regardless of sweat allergy.

  19. Distinguishing hyperhidrosis and normal physiological sweat production

    DEFF Research Database (Denmark)

    Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus

    2015-01-01

    of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. METHODS: Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results...... 100 mg/5 min. CONCLUSIONS: A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production....

  20. Nanoduct Sweat Conductivity Measurements in 2664 Patients: Relationship to Age, Arterial Blood Gas, Serum Electrolyte Profiles and Clinical Diagnosis

    Science.gov (United States)

    Sezer, Rabia Gonul; Aydemir, Gokhan; Akcan, Abdullah Baris; Paketci, Cem; Karaoglu, Abdulbaki; Aydinoz, Secil; Bozaykut, Abdulkadir

    2013-01-01

    Background The Nanoduct® device has acceptable diagnostic accuracy, but there is not enough systematic data supporting its usage in the diagnosis of cystic fibrosis (CF). Methods A retrospective review of patients with an indication for the sweat test was conducted. The conductivity test was repeated in patients who had values higher than 60 mmol/L, and they were referred for sweat chloride measurements. Associations between sweat conductivity measurements and age, gender, (pH, HCO3, pCO2, Na, K, Cl), family history, consanguinity, indications for the test and number of hospitalization were studied. Results Among 2,664 patients, 16 children had sweat conductivity values higher than 80. The median age of patients diagnosed with CF was 4 months old. Age, pH, HCO3, Na, Cl, K and the sweat conductivity test were statistically related (P conductivity test and the sweat test. Conclusions Patients suspected to have CF can be screened using the Nanoduct® conductivity device in non-qualified centers. PMID:23390474

  1. Evaluation of a minimally invasive system for measuring glucose area under the curve during oral glucose tolerance tests: usefulness of sweat monitoring for precise measurement.

    Science.gov (United States)

    Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Hamaguchi, Tomoya; Matsuo, Toshihiro; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi; Sato, Toshiyuki; Okada, Seiki; Tomita, Koji; Matsuhisa, Munehide; Kaneto, Hideaki; Kosugi, Keisuke; Maegawa, Hiroshi; Nakajima, Hiromu; Kashiwagi, Atsunori

    2013-05-01

    We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs). Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h. Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202-610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system. We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice. © 2013 Diabetes Technology Society.

  2. Development of a method for enhancing metabolomics coverage of human sweat by gas chromatography-mass spectrometry in high resolution mode.

    Science.gov (United States)

    Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2016-01-28

    Sweat has recently gained popularity as clinical sample in metabolomics analysis as it is a non-invasive biofluid the composition of which could be modified by certain pathologies, as is the case with cystic fibrosis that increases chloride levels in sweat. However, the whole composition of sweat is still unknown and there is a lack of analytical strategies for sweat analysis. The aim of the present study was to develop and validate a method for metabolomic analysis of human sweat by gas chromatography-time of flight/mass spectrometry (GC-TOF/MS) in high resolution mode. Thus, different sample preparation strategies were compared to check their effect on the profile of sweat metabolites. Sixty-six compounds were tentatively identified by the obtained MS information. Amino acids, dicarboxylic acids and other interesting metabolites such as myo-inositol and urocanic acid were identified. Among the tested protocols, methyoxiamination plus silylation after deproteinization was the most suited option to obtain a representative snapshot of sweat metabolome. The intra-day repeatability of the method ranged from 0.60 to 16.99% and the inter-day repeatability from 2.75 to 31.25%. As most of the identified metabolites are involved in key biochemical pathways, this study opens new possibilities to the use of sweat as a source of metabolite biomarkers of specific disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Acquired defects in CFTR-dependent β-adrenergic sweat secretion in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Courville, Clifford A; Tidwell, Sherry; Liu, Bo; Accurso, Frank J; Dransfield, Mark T; Rowe, Steven M

    2014-02-25

    Smoking-induced chronic obstructive pulmonary disease (COPD) is associated with acquired systemic cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. Recently, sweat evaporimetry has been shown to efficiently measure β-adrenergic sweat rate and specifically quantify CFTR function in the secretory coil of the sweat gland. To evaluate the presence and severity of systemic CFTR dysfunction in smoking-related lung disease using sweat evaporimetry to determine CFTR-dependent sweat rate. We recruited a cohort of patients consisting of healthy never smokers (N = 18), healthy smokers (12), COPD smokers (25), and COPD former smokers (12) and measured β-adrenergic sweat secretion rate with evaporative water loss, sweat chloride, and clinical data (spirometry and symptom questionnaires). β-adrenergic sweat rate was reduced in COPD smokers (41.9 ± 3.4, P sweat chloride was significantly greater in COPD smokers (32.8 ± 3.3, P sweat rate and female gender (β = 0.26), age (-0.28), FEV1% (0.35), dyspnea (-0.3), and history of smoking (-0.27; each P sweat rate was significantly reduced in COPD patients, regardless of smoking status, reflecting acquired CFTR dysfunction and abnormal gland secretion in the skin that can persist despite smoking cessation. β-adrenergic sweat rate and sweat chloride are associated with COPD severity and clinical symptoms, supporting the hypothesis that CFTR decrements have a causative role in COPD pathogenesis.

  4. Sweat function in the diabetic foot

    Directory of Open Access Journals (Sweden)

    Markendeya Nirmala

    2004-01-01

    Full Text Available Background: Autonomic dysfunction, an early manifestation of diabetic neuropathy, presents with altered sweating patterns, leading to dryness and fissuring. We conducted a study to assess the sweat function in the diabetic foot and to determine the interrelation between the duration of diabetes, sensation, fissuring, and sweating. Methods: The sweat function was assessed in 30 diabetic patients, 28 of whom had fissuring of the feet, using Ninhydrin impregnated discs. Results: There was a significant association between fissuring and sensation, but not between the duration of diabetes and fissuring and between loss of sweating and fissuring. In 18 patients (60% there was impairment or absence of sweating in the presence of normal sensation. Conclusion: Although fissuring increases with long-standing diabetes and sweating is reduced in diabetic patients with fissures on the foot, the correlation between these entities was not statistically significant. Since 60% patients had altered sweating in the presence of normal sensations, the sweat test can be used as an early indicator of diabetic neuropathy.

  5. Aspects of tests and assessment of filtering materials used for respiratory protection against bioaerosols. Part II: sweat in the environment, microorganisms in the form of a bioaerosol.

    Science.gov (United States)

    Majchrzycka, Katarzyna; Gutarowska, Beata; Brochocka, Agnieszka

    2010-01-01

    The second part of the article presents the results of a study of antimicrobial activity of filter nonwovens with an addition of biocides, as a function of the presence of sweat in the environment and the method of microbe deposition on a nonwoven in the form of a liquid and a bioaerosol. At the same time, the filtration efficiency of nonwovens against microorganisms in the form of a bioaerosol was tested with the dynamic method. The results showed that the addition of sweat on the surface of a nonwoven resulted in an insignificant decrease of biological activity that still remained high. Moreover, an active nonwoven showed biostatic and biocidal activity only when microbes were deposited on the surface in the form of a solution. The nonwoven did not show any biological activity after deposition of microorganisms with the dynamical method in the form of a bioaerosol.

  6. Tolerance Test of Eisenia Fetida for Sodium Chloride

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, M.; Stewart, A.J.

    2003-01-01

    Saltwater spills that make soil excessively saline often occur at petroleum exploration and production (E&P) sites and are ecologically damaging. Brine scars appear when produced water from an E&P site is spilled onto surrounding soil, causing loss of vegetation and subsequent soil erosion. Revegetating lands damaged by brine water can be difficult. The research reported here considers earthworms as a bioremedial treatment for increasing the salt mobility in this soil and encouraging plant growth and a healthy balance of soil nutrients. To determine the practical application of earthworms to remediate brine-contaminated soil, a 17-d test was conducted to establish salt tolerance levels for the common compost earthworm (Eisenia fetida) and relate those levels to soil salinity at brine-spill sites. Soil samples were amended with sodium chloride in concentrations ranging from 1 to 15 g/kg, which represent contamination levels at some spill sites. The survival rate of the earthworms was near 90% in all tested concentrations. Also, reproduction was noted in a number of the lower-concentration test replicates but absent above the 3-g/kg concentrations. Information gathered in this investigation can be used as reference in further studies of the tolerance of earthworms to salty soils, as results suggest that E. fetida is a good candidate to enhance remediation at brine-damaged sites.

  7. Optimization study for metabolomics analysis of human sweat by liquid chromatography-tandem mass spectrometry in high resolution mode.

    Science.gov (United States)

    Calderón-Santiago, M; Priego-Capote, F; Jurado-Gámez, B; Luque de Castro, M D

    2014-03-14

    Sweat has recently gained popularity as a potential tool for diagnostics and biomarker monitoring as it is a non-invasive biofluid the composition of which could be modified by certain pathologies, as is the case with cystic fibrosis, which increases chloride levels in sweat. The aim of the present study was to develop an analytical method for analysis of human sweat by liquid chromatography-mass spectrometry (LC-Q-TOF MS/MS) in high resolution mode. Thus, different sample preparation strategies and different chromatographic modes (HILIC and C18 reverse modes) were compared to check their effect on the profile of sweat metabolites. Forty-one compounds were identified by the MS/MS information obtained with a mass tolerance window below 4 ppm. Amino acids, dicarboxylic acids and other interesting metabolites such as inosine, choline, uric acid and tyramine were identified. Among the tested protocols, direct analysis after dilution was a suited option to obtain a representative snapshot of sweat metabolome. In addition, sample clean up by C18 SpinColumn SPE cartridges improved the sensitivity of most identified compounds and reduced the number of interferents. As most of the identified metabolites are involved in key biochemical pathways, this study opens new possibilities to the use of sweat as a source of metabolite biomarkers of specific disorders. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

    Science.gov (United States)

    Baker, Lindsay B

    2017-03-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.

  9. Printing artificial sweat using ink jet printers for the test set generation in forensics: an image quality assessment of the reproducibility of the printing results

    Science.gov (United States)

    Hildebrandt, Mario; Sturm, Jennifer; Dittmann, Jana

    2013-01-01

    In order to use scientific expert evidence in court hearings, several criteria must be met. In the US jurisdiction the Daubert decision2 has defined several criteria that might be assessed if a testimony is challenged. In particular the potential for testing or actual testing, as well as known or potential error rate are two very important criteria. In order to be able to compare the results with each other, the reproducible creation of evaluation samples is necessary. However, each latent fingerprint is unique due to external inuence factors such as sweat composition or pressure during the application of a trace. Hence, Schwarz1 introduces a method to print latent fingerprints using ink jet printers equipped with artificial sweat. In this paper we assess the image quality in terms of reproducibility and clarity of the printed artificial sweat patterns. For that, we determine the intra class variance from one printer on the same and on different substrates based on a subjective assessment, as well as the inter class variance between different printers of the same model using pattern recognition techniques. Our results indicate that the intra class variance is primarily inuenced by the drying behavior of the amino acid. The inter class is surprisingly large between identical models of one printer. Our evaluation is performed using 100 samples on an overhead foil and 50 samples on a compact disk surface with 5 different patterns (two line structures, a fingerprint image and two di_erent arrows with a larger area with amino acid) acquired with a Keyence VK-X110 laser scanning confocal microscope.11 The results show a significant difference between the two identical printers allowing for differentiating between them with an accuracy of up to 99%.

  10. Eccrine sweat gland development and sweat secretion.

    Science.gov (United States)

    Cui, Chang-Yi; Schlessinger, David

    2015-09-01

    Eccrine sweat glands help to maintain homoeostasis, primarily by stabilizing body temperature. Derived from embryonic ectoderm, millions of eccrine glands are distributed across human skin and secrete litres of sweat per day. Their easy accessibility has facilitated the start of analyses of their development and function. Mouse genetic models find sweat gland development regulated sequentially by Wnt, Eda and Shh pathways, although precise subpathways and additional regulators require further elucidation. Mature glands have two secretory cell types, clear and dark cells, whose comparative development and functional interactions remain largely unknown. Clear cells have long been known as the major secretory cells, but recent studies suggest that dark cells are also indispensable for sweat secretion. Dark cell-specific Foxa1 expression was shown to regulate a Ca(2+) -dependent Best2 anion channel that is the candidate driver for the required ion currents. Overall, it was shown that cholinergic impulses trigger sweat secretion in mature glands through second messengers - for example InsP3 and Ca(2+) - and downstream ion channels/transporters in the framework of a Na(+) -K(+) -Cl(-) cotransporter model. Notably, the microenvironment surrounding secretory cells, including acid-base balance, was implicated to be important for proper sweat secretion, which requires further clarification. Furthermore, multiple ion channels have been shown to be expressed in clear and dark cells, but the degree to which various ion channels function redundantly or indispensably also remains to be determined. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  11. Replacement of ammonium chloride when processing Scholven coals. (Tests conducted in rotating autoclave at 350 atmosheres. )

    Energy Technology Data Exchange (ETDEWEB)

    Grassl, G.; Schiffmann, F.

    1944-01-03

    Hydrogenation tests were conducted on coal from Scholven in view of difficulties in delivery of ammonium chloride to the Scholven works. The results were, that of the materials containing chlorine, ferrous chloride and water-soluble chlorine-bearing alumina appeared to be first and second choices as replacements for ammonium chloride. Ferrous chloride, used for an equivalent amount of chlorine, gave, other than a bit higher volatilization, the same results as ammonium chloride. Water-soluble chlorine-bearing alumina was found to be just as favorable as the ammonium chloride. But, there was a disadvantage. Since the alumina carried a lesser amount of chloride, a relatively larger amount (5.9%) of the material had to be used. This caused another problem. The increased residual material caused an overload on the reprocessing system. Water-soluble alumina at 1.9% was found to be unsuitable, because volatilization rose considerably with higher temperatures. Hydrated aluminum chloride (AlCl/sub 3/ . 6H/sub 2/O) was significantly more unsuitable than ammonium chloride. It was found that at .3 mV higher temperature, significant improvement could be noted, but certainly at the cost of volatilization, which rose sharply. Two tests of aluminum oxychloride, which contained more chlorine than the water-soluble alumina, showed suitable cracking properties, but figures as good as those obtained with ammonium chloride were not reached in treating asphalt and volatilization. Attempts to activate the chlorine in sodium chloride through ion exchange with ammonium sulfate did not succeed. The resulting substance gave worse results than did aluminum chlorohydrate. 1 table

  12. Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration

    OpenAIRE

    Vairo, Donato; Bruzzese, Laurie; Marlinge, Marion; Fuster, Lea; Adjriou, Nabil; Kipson, Nathalie; Brunet, Philippe; Cautela, Jennifer; Jammes, Yves; Mottola, Giovanna; Burtey, Stephane; Ruf, Jean; Guieu, Regis; Fenouillet, Emmanuel

    2017-01-01

    Electrolyte concentration in sweat depends on environmental context and physical condition but also on the pathophysiological status. Sweat analyzers may be therefore the future way for biological survey although how sweat electrolyte composition can reflect plasma composition remains unclear. We recruited 10 healthy subjects and 6 patients to have a broad range of plasma electrolyte concentrations (chloride, potassium and sodium) and pH. These variables were compared to those found in sweat ...

  13. Immunohistochemical sweat gland profiles.

    Science.gov (United States)

    Noël, Fanchon; Piérard, Gérald E; Delvenne, Philippe; Quatresooz, Pascale; Humbert, Philippe; Piérard-Franchimont, Claudine

    2013-09-01

    Human sweat glands are heterogeneous in their structures and functions. Accordingly, eccrine, apocrine, and apoeccrine glands are distinguished. Some immunohistochemical markers are expected to distinguish the sweat gland types in their secretory and excretory parts. This study used two sets of antibodies. The first panel was composed of antibodies directed to well-defined sweat gland structures. The molecular targets included the low-molecular-weight cytokeratins CAM 5.2, the S100-B protein, the epithelial membrane antigen (EMA), the carcinoembryonic antigen (CEA), and the lectin Ulex europaeus agglutinin-1 (UEA-1). A second exploratory panel of antibodies targeted syndecan-1 (CD138), NKI-C3 (CD63), and CD68. They were used to disclose some undescribed antigen expressions in human sweat glands. The first set of antibodies confirmed previous findings. The immunoreactivities of the three sweat gland types were similar in the excretory ducts. By contrast, they were distinguished in the deeper coiled secretory portions of the glands. Clues supporting their distinction and probably their functional activity were obtained by immunohistochemistry using the S100-B protein, CEA and CD63 antibodies. The immunoreactivity to the S100-B protein, CEA and CD63 possibly help identifying apoeccrine sweat glands or a peculiar functional activity of eccrine sweat glands. © 2013 Wiley Periodicals, Inc.

  14. TESTING OF 304L STAINLESS STEEL IN NITRIC ACID ENVIRONMENTS WITH FLUORIDES AND CHLORIDES

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.

    2010-10-04

    Impure radioactive material processed in nitric acid solutions resulted in the presence of chlorides in a dissolver fabricated from 304L stainless steel. An experimental program was conducted to study the effects of chloride in nitric acid/fluoride solutions on the corrosion of 304L stainless steel. The test variables included temperature (80, 95, and 110 C) and the concentrations of nitric acid (6, 12, and 14 M), fluoride (0.01, 0.1, and 0.2 M) and chloride (100, 350, 1000, and 2000 ppm). The impact of welding was also investigated. Results showed that the chloride concentration alone was not a dominant variable affecting the corrosion, but rather the interaction of chloride with fluoride significantly affected corrosion.

  15. Microwave corneosurfametry and the short-duration dansyl chloride extraction test for rating concentrated irritant surfactants.

    Science.gov (United States)

    Goffin, V; Piérard, G E

    2001-01-01

    There are ethical concerns to conduct in vivo tests in the animal and human to provide evidence that cosmetics and other topical products are safe. To compare two methods, namely the short-duration dansyl chloride extraction test and the microwave corneosurfametry bioassay, to test the irritation potential of concentrated surfactant systems. Five surfactants and water were tested using the in vivo test and the bioassay. A significant linear correlation was found between data yielded by the two procedures. The short-duration dansyl chloride extraction test and the microwave corneosurfametry bioassay provide similar information. The latter has the advantage of being safe.

  16. Normative data for regional sweat sodium concentration and whole-body sweating rate in athletes.

    Science.gov (United States)

    Baker, Lindsay B; Barnes, Kelly A; Anderson, Melissa L; Passe, Dennis H; Stofan, John R

    2016-01-01

    The purpose of this study was to establish normative data for regional sweat sodium concentration ([Na+]) and whole-body sweating rate in athletes. Data from 506 athletes (367 adults, 139 youth; 404 male, 102 female) were compiled from observational athlete testing for a retrospective analysis. The participants were skill/team-sport (including American football, baseball, basketball, soccer and tennis) and endurance (including cycling, running and triathlon) athletes exercising in cool to hot environmental conditions (15-50 °C) during training or competition in the laboratory or field. A standardised regional absorbent patch technique was used to determine sweat [Na+] on the dorsal mid-forearm. Whole-body sweat [Na+] was predicted using a published regression equation (y = 0.57x+11.05). Whole-body sweating rate was calculated from pre- to post-exercise change in body mass, corrected for fluid/food intake (ad libitum) and urine output. Data are expressed as mean ± SD (range). Forearm sweat [Na+] and predicted whole-body sweat [Na+] were 43.6 ± 18.2 (12.6-104.8) mmol · L(-1) and 35.9 ± 10.4 (18.2-70.8) mmol · L(-1), respectively. Absolute and relative whole-body sweating rates were 1.21 ± 0.68 (0.26-5.73) L · h(-1) and 15.3 ± 6.8 (3.3-69.7) ml · kg(-1) · h(-1), respectively. This retrospective analysis provides normative data for athletes' forearm and predicted whole-body sweat [Na+] as well as absolute and relative whole-body sweating rate across a range of sports and environmental conditions.

  17. Sweat collection capsule

    Science.gov (United States)

    Greenleaf, J. E.; Delaplaine, R. W. (Inventor)

    1980-01-01

    A sweat collection capsule permitting quantitative collection of sweat is described. The device consists of a frame held immobile on the skin, a closure secured to the frame and absorbent material located next to the skin in a cavity formed by the frame and the closure. The absorbent material may be removed from the device by removing the closure from the frame while the frame is held immobile on the skin.

  18. Efficient sweat reduction of three different antiperspirant application forms during stress-induced sweating.

    Science.gov (United States)

    Schmidt-Rose, T; Lehmbeck, F; Bürger, A; Windisch, B; Keyhani, R; Max, H

    2013-12-01

    Stress sweating can occur in everyday situations independently of thermally-induced perspiration. It is triggered by emotionally challenging situations and leads to underarm wetness and a characteristic unpleasant malodor. In this study, we aimed to determine the long-term efficacy of three unperfumed antiperspirant (AP) formulas for different application forms (roll-on, stick, aerosol) against stress-induced sweating and malodor formation. We utilized the widely accepted Trier Social Stress Test (TSST) to induce psychosocial stress in female and male volunteers (18 - 40 years) and determined physiological stress parameters. To additionally assess the efficacy of the test AP roll-on against thermally-induced sweating, a hot room study was performed. Increasing heart rates and an augmentation of saliva cortisol levels during the TSST indicated a substantial stress reaction which was paralleled by a pronounced sweat production in the untreated axillae of both males and females. Forty-eight hours after application, all three test APs significantly decreased the amount of sweat in the treated axillae independent of gender. With respect to AP effects on malodor production, trained sniffers assessed sweat samples collected during the TSST from the untreated axillae as significantly more malodorous than comparable samples from the AP-treated axillae. Also, independent of gender the test AP roll-on significantly decreased the thermally-induced sweat in the AP-treated axilla. We show for the first time a highly effective reduction of emotionally-induced axillary sweating and malodor production for three different application forms 48 h after the last product use. The specially developed roll-on, stick, and aerosol AP provide long-term protection against stress-induced sweat which is of high relevance in everyday life. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  19. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. 'My sweat my health': Real time sweat analysis using wearable micro-fluidic devices

    OpenAIRE

    Curto, Vincenzo F.; Angelov, Nikolay; Coyle, Shirley; Byrne, Robert; Hughes, Sarah; Moyna, Niall; Diamond, Dermot; Benito-Lopez, Fernando

    2011-01-01

    In this work a robust, non-invasive and wearable micro-fluidic system was developed and employed to analyse pH of sweat in real time during exercise. The device is incorporated in an optical detection platform designed to provide real-time information on sweat composition. The device has been tested by monitoring the pH of sweat during 55 minutes of cycling activity. During these trials, the data obtained by the micro-fluidic system was compared to pH measurements obtained in parallel studies...

  1. Chloride diffusivity in red mud-ordinary portland cement concrete determined by migration tests

    Directory of Open Access Journals (Sweden)

    Daniel Véras Ribeiro

    2011-01-01

    Full Text Available Red mud, which is a solid waste produced in the alumina production process, is classified as dangerous due to its high pH. In this work, the concentration of chlorides was monitored by measuring the conductivity of the anolyte, which initially was distilled water. The steady and nonsteady-state chloride diffusion coefficients were estimated from the "time lag"� and "equivalent time" between diffusion and migration experiments. The capillary water absorption, apparent porosity and pore size distribution of concretes were also analyzed. The addition of red mud apparently ensured lower chloride diffusion in the tested mixtures due to its superfine particle-size distribution and its "filler"� effect. Red mud lengthened the service life of the concrete to 35 years (double that of the reference concrete. This finding is very positive since it indicates a delay in the onset of the rebar corrosion process caused by the migration of chloride ions.

  2. CFTR-dependent chloride efflux in cystic fibrosis mononuclear cells is increased by ivacaftor therapy.

    Science.gov (United States)

    Guerra, Lorenzo; D'Oria, Susanna; Favia, Maria; Castellani, Stefano; Santostasi, Teresa; Polizzi, Angela M; Mariggiò, Maria A; Gallo, Crescenzio; Casavola, Valeria; Montemurro, Pasqualina; Leonetti, Giuseppina; Manca, Antonio; Conese, Massimo

    2017-07-01

    The Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) potentiator ivacaftor (Kalydeco®) improves clinical outcome in G551D cystic fibrosis (CF) patients. Here, we have investigated whether ivacaftor has a clinical impact on non-G551D gating mutations and function of circulating leukocytes as well. Seven patients were treated with ivacaftor and evaluated at baseline, and at 1-3 and 6 months. Besides clinical and systemic inflammatory parameters, circulating mononuclear cells (MNC) were evaluated for CFTR-dependent chloride efflux by spectrofluorimetry, neutrophils for oxidative burst by cytofluorimetry and HVCN1 mRNA expression by real time PCR. Ivacaftor determined a significant decrease in sweat chloride concentrations at all time points during treatment. Body mass index (BMI), FEV1 , and FVC showed an increasing trend. While C-reactive protein decreased significantly at 2 months, the opposite behavior was noticed for circulating monocytes. CFTR activity in MNC was found to increase significantly at 3 and 6 months. Neutrophil oxidative burst peaked at 2 months and then decreased to baseline. HVCN1 mRNA expression was significantly higher than baseline at 1-3 months and decreased after 6 months of treatment. The chloride efflux in MNC correlated positively with both FEV1 and FVC. On the other hand, sweat chloride correlated positively with CRP and WBC, and negatively with both respiratory function tests. A cluster analysis confirmed that sweat chloride, FEV1 , FVC, BMI, and MNC chloride efflux behaved as a single entity over time. In patients with non-G551D mutations, ivacaftor improved both chloride transport in sweat ducts and chloride efflux in MNC, that is, functions directly imputed to CFTR. © 2017 Wiley Periodicals, Inc.

  3. Real-time sweat analysis via alternating current conductivity of artificial and human sweat

    Science.gov (United States)

    Liu, Gengchen; Alomari, Mahmoud; Sahin, Bunyamin; Snelgrove, Samuel E.; Edwards, Jeffrey; Mellinger, Axel; Kaya, Tolga

    2015-03-01

    Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.

  4. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring.

    Science.gov (United States)

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B; Yelamarthi, Kumar; Kaya, Tolga

    2018-02-10

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm², with an average error in accuracy of 18% compared to manual sweat rate readings.

  5. A wearable multisensing patch for continuous sweat monitoring.

    Science.gov (United States)

    Anastasova, Salzitsa; Crewther, Blair; Bembnowicz, Pawel; Curto, Vincenzo; Ip, Henry Md; Rosa, Bruno; Yang, Guang-Zhong

    2017-07-15

    In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the platform is designed such that continuous flow of sweat can pass through an array of flexible microneedle type of sensors (50µm diameter) incorporated in a microfluidic channel. Potentiometric sodium ion sensors were developed using a polyvinyl chloride (PVC) functional membrane deposited on an electrochemically deposited internal layer of Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer. The pH sensing layer is based on a highly sensitive membrane of iridium oxide (IrOx). The amperometric-based lactate sensor consists of doped enzymes deposited on top of a semipermeable copolymer membrane and outer polyurethane layers. Real-time data were collected from human subjects during cycle ergometry and treadmill running. A detailed comparison of sodium, lactate and cortisol from saliva is reported, demonstrating the potential of the multi-sensing platform for tracking these outcomes. In summary, a fully integrated sensor for continuous, simultaneous and selective measurement of sweat metabolites, electrolytes and temperature was achieved using a flexible microfluidic platform. This system can also transmit information wirelessly for ease of collection and storage, with the potential for real-time data analytics. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Potential substitution of ammonium chloride in Ruhr coal hydrogenation. (Previous test results)

    Energy Technology Data Exchange (ETDEWEB)

    Grassl

    1943-10-20

    The report related that ammonium chloride could be nearly totally replaced by equivalent amounts of elemental chlorine in the form of gas, chlorinated grinding oil, moderately chlorinated coal, as well as hydrogen chloride. Similar results were obtained using organic chloride compounds, such as carbon tetrachloride. Sulfur monochloride was also considered a substitute for ammonium chloride, since sulfuric acid and ammonium fluoride were considered unfavorable at the time. At a reaction temperature 1/2 mV higher than usual, phosphoric acid gave results similar to those of ammonium chloride except for splitting. By using metal powders (Fe, Al, Zn, Sn, etc.), the amount of chlorine could be reduced from 1/3 to 1/2, yet to attain a favorable reduction in asphalt as with NH/sub 4/Cl, a slight temperature increase was necessary. Tests with chlorine-containing water-soluble aluminum oxide as well as aqueous aluminum chloride appeared to be good prospects and were to be followed up. A number of summaries were referred to in relation to this report.

  7. Aluminium in human sweat.

    Science.gov (United States)

    Minshall, Clare; Nadal, Jodie; Exley, Christopher

    2014-01-01

    It is of burgeoning importance that the human body burden of aluminium is understood and is measured. There are surprisingly few data to describe human excretion of systemic aluminium and almost no reliable data which relate to aluminium in sweat. We have measured the aluminium content of sweat in 20 healthy volunteers following mild exercise. The concentration of aluminium ranged from 329 to 5329μg/L. These data equate to a daily excretion of between 234 and 7192μg aluminium and they strongly suggest that perspiration is the major route of excretion of systemic aluminium in humans. Copyright © 2013 Elsevier GmbH. All rights reserved.

  8. Sweat lipid mediator profiling: a non-invasive approach for cutaneous research

    Science.gov (United States)

    Sweat is a complex biological fluid with potential diagnostic value for the investigation of skin disorders. Previous efforts in sweat testing focused on analysis of small molecules and ions for forensic and diagnostic testing, but with advances in analytical and sweat collection techniques, there h...

  9. [What causes English sweats?].

    Science.gov (United States)

    Rimar, Yossi

    2004-09-01

    English sweating disease also known as Sudor Anglicus is one of the least familiar epidemics of the Middle Ages, striking England 5 times during the 15th and 16th centuries before fading. This article will discuss the knowledge available to us about this fascinating epidemic, its characteristics and causes.

  10. Hyperhidrosis (Excessive Sweating)

    Science.gov (United States)

    ... medicines also can cause this type of hyperhidrosis. Anxiety and embarrassment Both types of hyperhidrosis can cause people to feel extremely anxious and embarrassed. Students often avoid raising their hand during class. Many teens never date. Adults may hide the sweat stains ...

  11. On sweat analysis for quantitative estimation of dehydration during physical exercise.

    Science.gov (United States)

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Eskofier, Bjoern M

    2015-08-01

    Quantitative estimation of water loss during physical exercise is of importance because dehydration can impair both muscular strength and aerobic endurance. A physiological indicator for deficit of total body water (TBW) might be the concentration of electrolytes in sweat. It has been shown that concentrations differ after physical exercise depending on whether water loss was replaced by fluid intake or not. However, to the best of our knowledge, this fact has not been examined for its potential to quantitatively estimate TBW loss. Therefore, we conducted a study in which sweat samples were collected continuously during two hours of physical exercise without fluid intake. A statistical analysis of these sweat samples revealed significant correlations between chloride concentration in sweat and TBW loss (r = 0.41, p sweat osmolality and TBW loss (r = 0.43, p sweat samples.

  12. Excretion of Δ9-Tetrahydrocannabinol in Sweat

    Science.gov (United States)

    Huestis, Marilyn A.; Scheidweiler, Karl B.; Saito, Takeshi; Fortner, Neil; Abraham, Tsadik; Gustafson, Richard A.; Smith, Michael L.

    2008-01-01

    Sweat testing is a noninvasive technique for monitoring drug exposure over a 7-day period in treatment, criminal justice, and employment settings. We evaluated Δ9-tetrahydrocannabinol (THC) excretion in 11 daily cannabis users after cessation of drug use. PharmChek® sweat patches worn for 7 days were analyzed for THC by gas chromatography-mass spectrometry (GC/MS). The limit of quantification (LOQ) for the method was 0.4 ng THC/patch. Sweat patches worn the first week of continuously monitored abstinence had THC above the United States Substance Abuse Mental Health Services Administration’s proposed cutoff concentration for federal workplace testing of 1 ng THC/patch. Mean ± S.E.M. THC concentrations were 3.85 ± 0.86 ng THC/patch. Eight of 11 subjects had negative patches the second week and one produced THC positive patches for four weeks of monitored abstinence. We also tested daily and weekly sweat patches from 7 subjects who were administered oral doses of up to 14.8 mg THC/day for five consecutive days. In this oral THC administration study, no daily or weekly patches had THC above the LOQ; concurrent plasma THC concentrations were all less than 6.1 μg/L. In conclusion, using proposed federal cutoff concentrations, most daily cannabis users will have a positive sweat patch in the first week after ceasing drug use and a negative patch after subsequent weeks, although patches may remain positive for four weeks or more. Oral ingestion of up to 14.8 mg THC daily does not produce a THC positive sweat patch test. PMID:17481836

  13. Cannabis Use Surveillance by Sweat Analysis.

    Science.gov (United States)

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  14. Immediate Wheal Reactivity to Autologous Sweat in Atopic Dermatitis Is Associated with Clinical Severity, Serum Total and Specific IgE and Sweat Tryptase Activity.

    Science.gov (United States)

    Ilves, Tiina; Virolainen, Anu; Harvima, Ilkka Tapani

    2016-01-01

    Sweating can worsen atopic dermatitis (AD). The purpose of this work was to study the associations between reactivity to autologous sweat and the clinical severity of AD as well as investigate the possible wheal-inducing factors of sweat. Intracutaneous skin tests with autologous sweat were performed on 50 AD patients and 24 control subjects. In skin biopsies, tryptase and PAR-2 were enzyme and immunohistochemically stained. The associations between skin test reactivity and sweat histamine concentration, tryptase or chymase activity levels, tryptase or PAR-2 expression and AD clinical severity or IgE levels were investigated. The wheal reactions in the intracutaneous tests with autologous sweat were positive, weakly positive and negative in 38, 34 and 28% of the AD patients, respectively, and in 4, 46 and 50% of the healthy controls, respectively (p = 0.008). In AD, the wheal reaction was associated significantly with clinical severity, serum total and specific IgE levels and sweat tryptase activity, but not with sweat histamine and chymase. In nonlesional AD skin, the percentage of PAR-2+ mast cells (MCs) or the number of tryptase+ MCs did not differ significantly between the intracutaneous test reactivity groups. Reactivity to autologous sweat correlates with the clinical severity of AD, and tryptase may be one of the factors involved in the sweat-induced wheal. © 2016 S. Karger AG, Basel.

  15. Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness

    Directory of Open Access Journals (Sweden)

    E. Pereira

    Full Text Available In developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion test - CAIM, that simulates the chloride attack. The three variables are: concrete cover thickness, use of silica fume and the water/binder ratio. It was found, by analysis of variance of the weight loss of the steel bars and chloride content in the concrete cover thickness, there is significant influence of the three variables. Also, the results indicate that the addition of silica fume is the path to improve the corrosion protection of low water/binder ratio concretes (like 0.4 and elevation of the concrete cover thickness is the most effective solution to increase protection of high water/binder ratio concrete (above 0.5.

  16. Sweating dysfunction in Parkinson's disease

    NARCIS (Netherlands)

    Swinn, L; Schrag, A; Viswanathan, R; Lees, A; Quinn, N; Bloem, Bastiaan R.

    2003-01-01

    We sought to determine the prevalence and nature of sweating disturbances in patients with Parkinson's disease (PD), and investigated their correlation with other clinical features and with Quality of Life (QoL) measures. A questionnaire on symptoms and consequences of sweating dysfunction was

  17. Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat.

    Science.gov (United States)

    Morgan, R M; Patterson, M J; Nimmo, M A

    2004-09-01

    To determine whether acute exercise-heat-induced dehydration affects sweat composition, eight males cycled for 2 h at 39.5 +/- 1.6% VO2peak on two separate occasions in a hot-humid environment (38.0 +/- 0.0 degrees C, 60.0 +/- 0.1% relative humidity). During exercise, subjects ingested either no fluid (dehydration) or a 20 mmol L(-1) sodium chloride solution (euhydration). The volume of solution, calculated from whole-body sweat loss and determined in a familiarization trial, was ingested at 0 min and every 15 min thereafter. Venous blood was collected at 0, 60 and 120 min of exercise and sweat was aspirated from a patch located on the dominant forearm at 120 min. Following the 2-h cycling exercise, sweat [Na+] and [Cl-] was greater (P sweat [Na+] and [Cl-] which was potentially related to greater extracellular fluid [Na+], plasma aldosterone or sympathetic nervous activity.

  18. Sweating rate and sweat composition during exercise and recovery in ambient heat and humidity.

    Science.gov (United States)

    McCutcheon, L J; Geor, R J; Hare, M J; Ecker, G L; Lindinger, M I

    1995-11-01

    The objective of this study was to determine the composition and extent of sweat losses during submaximal exercise under hot and humid conditions and to compare these findings with the same exercise protocol conducted under cool, dry and hot, dry conditions. Five Thoroughbred horses (age 3 to 6) completed exercise tests under each of 3 environmental conditions in random order: cool, dry (CD), room temperature (T) = 20 degrees C, relative humidity (RH) = 45-55%; hot, dry (HD), T = 32-34 degrees C, RH = 45-55%; and hot, humid (HH), T = 32-34 degrees C, RH = 80-85%. Horses exercised at 50% of their predetermined VO2max on a treadmill set at a 10% slope until attainment of a pulmonary artery blood temperature of 41.5 degrees C followed by a 60 min recovery. Sweat was collected from a sealed polyethylene pouch enclosing a 150 cm2 area on the lateral thorax. During exercise and the first 30 min of recovery, sweat fluid losses were 7.9 +/- 0.7 litres, 9.9 +/- 0.5 litres and 6.6 +/- 1.2 litres (mean +/- s.e.m.) for CD, HD and HH, respectively. Sweating rate (SR), calculated from sweat volume per unit area of enclosed skin, was lowest in CD and similar in HD and HH during exercise such that at end of exercise in HH (16.5 min) calculated sweat losses were approximately 5% and 32% higher than in HD and CD, respectively. In recovery, SR declined in all conditions but was significantly lower in CD (P Sweating was detectable until 30 min recovery in CD, 45 min recovery in HD and 60 min recovery in HH. Sweat composition and osmolality was different under the 3 environmental conditions and changed gradually during exercise and recovery in all conditions. Osmolality and [Na] was highest in HD and lowest in CD. During exercise, [Na] increased with increasing SR. Although exercise duration was significantly decreased in HH (16.5 +/- 1 min) when compared to HD (28 +/- 2 min) and CD (37 +/- 2 min), fluid and ion losses in HH were comparable to those in HD as a result of a high SR and

  19. Pituitary adenylate cyclase-activating polypeptide promotes eccrine gland sweat secretion.

    Science.gov (United States)

    Sasaki, S; Watanabe, J; Ohtaki, H; Matsumoto, M; Murai, N; Nakamachi, T; Hannibal, J; Fahrenkrug, J; Hashimoto, H; Watanabe, H; Sueki, H; Honda, K; Miyazaki, A; Shioda, S

    2017-02-01

    Sweat secretion is the major function of eccrine sweat glands; when this process is disturbed (paridrosis), serious skin problems can arise. To elucidate the causes of paridrosis, an improved understanding of the regulation, mechanisms and factors underlying sweat production is required. Pituitary adenylate cyclase-activating polypeptide (PACAP) exhibits pleiotropic functions that are mediated via its receptors [PACAP-specific receptor (PAC1R), vasoactive intestinal peptide (VIP) receptor type 1 (VPAC1R) and VPAC2R]. Although some studies have suggested a role for PACAP in the skin and several exocrine glands, the effects of PACAP on the process of eccrine sweat secretion have not been examined. To investigate the effect of PACAP on eccrine sweat secretion. Reverse transcriptase-polymerase chain reaction and immunostaining were used to determine the expression and localization of PACAP and its receptors in mouse and human eccrine sweat glands. We injected PACAP subcutaneously into the footpads of mice and used the starch-iodine test to visualize sweat-secreting glands. Immunostaining showed PACAP and PAC1R expression by secretory cells from mouse and human sweat glands. PACAP immunoreactivity was also localized in nerve fibres around eccrine sweat glands. PACAP significantly promoted sweat secretion at the injection site, and this could be blocked by the PAC1R-antagonist PACAP6-38. VIP, an agonist of VPAC1R and VPAC2R, failed to induce sweat secretion. This is the first report demonstrating that PACAP may play a crucial role in sweat secretion via its action on PAC1R located in eccrine sweat glands. The mechanisms underlying the role of PACAP in sweat secretion may provide new therapeutic options to combat sweating disorders. © 2016 British Association of Dermatologists.

  20. Testing a degradable topical varnish of cetylpyridinium chloride in an experimental dental biofilm model.

    Science.gov (United States)

    Steinberg, D; Moldovan, M; Molukandov, D

    2001-08-01

    Dental biofilms are highly associated with the development of dental caries. Novel drug delivery systems are being developed in order to eliminate cariogenic bacteria from the dental biofilms. We formulated two degradable sustained release varnishes, based on acrylic resin, with cetylpyridinium chloride (CPC) as the active agent. These formulations were tested in a dental biofilm model. The retention of CPC in the biofilm was dependent upon the pharmaceutical additives of the varnish. Both varnishes decreased bacterial adhesion, while also demonstrating marked antibacterial properties against the bacteria in the biofilm.

  1. Sweat secretion rates in growth hormone disorders

    DEFF Research Database (Denmark)

    Sneppen, S B; Main, K M; Juul, A

    2000-01-01

    While increased sweating is a prominent symptom in patients with active acromegaly, reduced sweating is gaining status as part of the growth hormone deficiency (GHD) syndrome.......While increased sweating is a prominent symptom in patients with active acromegaly, reduced sweating is gaining status as part of the growth hormone deficiency (GHD) syndrome....

  2. Why Do I Sweat So Much?

    Science.gov (United States)

    ... Your Parents - or Other Adults Why Do I Sweat So Much? KidsHealth > For Teens > Why Do I Sweat So Much? Print A A A en español ¿Por qué sudo tanto? It's perfectly normal to sweat. Sweating plays an important health role because it ...

  3. Sweat mechanisms and dysfunctions in atopic dermatitis.

    Science.gov (United States)

    Hendricks, Aleksi J; Vaughn, Alexandra R; Clark, Ashley K; Yosipovitch, Gil; Shi, Vivian Y

    2018-02-01

    Skin barrier dysfunction is inherent to atopic dermatitis (AD), causing dryness, irritation, and increased permeability to irritants, allergens and pathogens. Eccrine sweat functions as part of the skin's protective barrier. Variations in sweat responses have been observed in patients with AD, and altered sweat composition and dynamics are under-recognized as important factors in the disease cycle. This review discusses the role that sweat plays in the pathogenesis of AD, examines evidence on abnormal sweat composition, secretion, and neuro-immune responses to sweat in atopic skin, and highlights the value of sweat management. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  4. Influence of sex and growth hormone deficiency on sweating

    DEFF Research Database (Denmark)

    Main, K; Nilsson, K O; Skakkebaek, N E

    1991-01-01

    Sweat secretion rate (SSR) was measured by the pilocarpine iontophoresis test in (a) 254 healthy children and adolescents (aged 6.0 to 19.2 years, mean age 11.2 years); in (b) 58 healthy adults (aged 20.4 to 75.2 years, mean age 37.6 years); and in (c) eight prepubertal patients with growth hormone...... in sweat excretion rate from childhood to adulthood showed a difference between the sexes. Both pre-pubertal and pubertal boys had a lower secretion value than adult men (p less than 0.001 and 0.01, respectively), whereas girls showed higher secretion values than adult women (p less than 0.01 and p less...... min-1). We conclude that (a) sweat secretion pattern in children shows a significant sex difference and (b) sweating in children is dependent on growth hormone....

  5. Pilocarpine iontophoresis test

    DEFF Research Database (Denmark)

    Hjortskov, N; Jepsen, Leif; Nielsen, B

    1995-01-01

    regional sweat secretion and whole-body sweat secretion. We conclude that the pilocarpine iontophoresis test reflects heat- and exercise-induced sweating capacity. However, this test does not induce maximal sweating, and it cannot be used as a single reliable predictor of whole-body sweating, due......The pilocarpine iontophoresis test (P-test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P-test reflects whole-body and regional sweat secretion...... during exercise in the heat. Finally, we determined whether the P-test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone-deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion...

  6. Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

    Science.gov (United States)

    Widenor, W. M.

    1978-01-01

    A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

  7. Testing of a sodium/nickel chloride (ZEBRA) battery for electric propulsion of ships and vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Kluiters, E.C.; Schmal, D.; Veen, W.R. ter [TNO Inst. of Environmental Sciences, Energy Research and Process Innovation, Apeldoorn (Netherlands); Posthumus, K.J.C.M. [Royal Netherlands Navy, The Haag (Netherlands). Dept. of Naval Architecture and Marine Engineering

    1999-07-01

    One of the promising future batteries for electric propulsion of vehicles and ships is the sodium/nickel chloride or ZEBRA (Zero Emission Battery Research Activities) battery. Despite some disadvantages with respect to the high temperature, the advantages with respect to specific energy and energy density are such that, especially in applications where the battery is used on a more or less continuous basis (e.g., in delivery vans and taxies) it is an interesting candidate battery. Another interesting application is on board of ships, like submarines or future electrical surface ships with electric propulsion. In 1995 a 2 year feasibility study, including experimental testing of a 10 kW h battery, was completed. This investigated the naval applicability of the sodium/sulphur battery, which is also a high temperature battery. Here the limited, experimentally proven, life-time of the batteries was of about 1.5 years and this made naval application almost impossible. A paper about this study was presented at the 19th International Power Sources Symposium held at Brighton, England, in April 1995. Because of the more or less comparable specifications on specific energy and the more promising results of the life-time and field tests with sodium/nickel chloride batteries, a ZEBRA battery from AEG Anglo Batteries has been tested for naval applications. This was done by simulating the charge and discharge as it occurs in practice for the applications investigated. With respect to the electrical ship application (investigated for the Royal Netherlands Navy) the power versus time taken from the battery was simulated as well as the charge procedures. The same can be done for the vehicle application: in this case typical drive cycles for a van or taxi are translated to power versus time taken from the battery. The results of the tests for application of the battery in naval ships are very promising. (orig.)

  8. Metabolomics analysis of human sweat collected after moderate exercise.

    Science.gov (United States)

    Delgado-Povedano, M M; Calderón-Santiago, M; Luque de Castro, M D; Priego-Capote, F

    2018-01-15

    Sweat is a promising biofluid scarcely used in clinical analysis despite its non-invasive sampling. A more frequent clinical use of sweat requires to know its whole composition, especially concerning to non-polar compounds, and the development of analytical strategies for its characterization. The aim of the present study was to compare different sample preparation strategies to maximize the detection of metabolites in sweat from humans collected after practicing moderate exercise. Special emphasis was put on non-polar compounds as they have received scant attention in previous studies dealing with this biofluid. Sample preparation by liquid-liquid extraction (LLE) using extractants with different polarity index was compared to deproteination. Then, derivatization by methoxymation with subsequent silylation was compared to direct analysis of sweat extracts to check the influence of derivatization on the subsequent determination of volatile organic compounds (VOCs). 135 compounds were tentatively identified by combining spectral and retention time information after analysis by gas chromatography coupled to mass spectrometry in high resolution mode (GC-TOF/MS). Lipids, VOCs, benzenoids and other interesting metabolites such as alkaloids and ethanolamines were identified. Among the tested protocols, methyoxiamination plus silylation after LLE with dichloromethane was the best option to obtain a representative snapshot of sweat metabolome collected from different body parts after moderate exercise. Passive and active sweat pools from a cohort of volunteers (n = 6) were compared to detect compositional differences which can be explained by the sampling process and sweating induction. As most of the identified compounds are metabolites involved in key biochemical pathways, this study opens new opportunities to extend the applicability of human sweat as a source of metabolite biomarkers of pathologies or specific processes such as dehydration or nutritional unbalance

  9. Comparison of fabric skins for the simulation of sweating on thermal manikins

    Science.gov (United States)

    Koelblen, Barbara; Psikuta, Agnes; Bogdan, Anna; Annaheim, Simon; Rossi, René M.

    2017-09-01

    Sweating is an important thermoregulatory process helping to dissipate heat and, thus, to prevent overheating of the human body. Simulations of human thermo-physiological responses in hot conditions or during exercising are helpful for assessing heat stress; however, realistic sweating simulation and evaporative cooling is needed. To this end, thermal manikins dressed with a tight fabric skin can be used, and the properties of this skin should help human-like sweat evaporation simulation. Four fabrics, i.e., cotton with elastane, polyester, polyamide with elastane, and a skin provided by a manikin manufacturer (Thermetrics) were compared in this study. The moisture management properties of the fabrics have been investigated in basic tests with regard to all phases of sweating relevant for simulating human thermo-physiological responses, namely, onset of sweating, fully developed sweating, and drying. The suitability of the fabrics for standard tests, such as clothing evaporative resistance measurements, was evaluated based on tests corresponding to the middle phase of sweating. Simulations with a head manikin coupled to a thermo-physiological model were performed to evaluate the overall performance of the skins. The results of the study showed that three out of four evaluated fabrics have adequate moisture management properties with regard to the simulation of sweating, which was confirmed in the coupled simulation with the head manikin. The presented tests are helpful for comparing the efficiency of different fabrics to simulate sweat-induced evaporative cooling on thermal manikins.

  10. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.

    Science.gov (United States)

    Koh, Ahyeon; Kang, Daeshik; Xue, Yeguang; Lee, Seungmin; Pielak, Rafal M; Kim, Jeonghyun; Hwang, Taehwan; Min, Seunghwan; Banks, Anthony; Bastien, Philippe; Manco, Megan C; Wang, Liang; Ammann, Kaitlyn R; Jang, Kyung-In; Won, Phillip; Han, Seungyong; Ghaffari, Roozbeh; Paik, Ungyu; Slepian, Marvin J; Balooch, Guive; Huang, Yonggang; Rogers, John A

    2016-11-23

    Capabilities in health monitoring enabled by capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible, and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of the skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose, and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH, and concentration of chloride and lactate. Copyright © 2016, American Association for the Advancement of Science.

  11. Durability Evaluation in Concrete Using Cracked Permeability and Chloride Permeability Tests

    Directory of Open Access Journals (Sweden)

    V. M. Sounthararajan

    2013-01-01

    Full Text Available The objective of this study is to identify the possibilities of utilizing the quarry dust in concrete to obtain an improved strength and durability properties of concrete. In the present study, the addition of quarry dust as alternative for natural sand has been investigated, and the durability properties of concrete were evaluated systematically by means of cracked water permeability and rapid chloride permeability tests. The permeability of concrete was assessed with initial stress applied to the concrete specimen and later checked for water permeability. Concrete mixes were casted using ordinary river sand and compared with 100% quarry dust substituted concrete. The addition of quarry dust significantly improved the concrete matrix properties in terms of strength and permeability resistance. The addition of fine quarry dust in concrete resulted in improved matrix densification compared to conventional concrete. Matrix densification has been studied qualitatively through petrographical examination using digital optical microscopy.

  12. Sweat fluid and ion losses in horses during training and competition in cool vs. hot ambient conditions: implications for ion supplementation.

    Science.gov (United States)

    McCutcheon, L J; Geor, R J

    1996-07-01

    The objectives of this study were to: 1) determine incremental and total sweat fluid and ion losses during and following (a) exercise training and (b) a treadmill Speed and Endurance exercise test (SEET) which simulated running speeds and distances required for each phase of an Olympic level (CCI****) 3-day-event in cool and hot ambient conditions and 2) determine the requirement for ion supplementation based on the calculated ion losses associated with these activities. Six exercise-trained Thoroughbred horses completed 2 weeks of exercise training in each of 2 ambient conditions: cool, dry (CD, room temperature [T] = 20-22 degrees C, relative humidity [RH] = 45-55%), or hot and humid (HH, T = 33-35 degrees C, RH = 80-85%). Following the 2 week period of training in either CD or HH conditions, horses completed a SEET under similar conditions (either CD, or hot and dry (HD, T = 33-35 degrees C, RH = 45-55%). Sweating rate and sweat ion composition for each 5 min interval was determined from sweat samples collected from a sealed pouch attached to the lateral thorax. Total sweat fluid losses during training in the heat were 2- or 3-fold greater when compared to CD. Similarly, sweat fluid losses associated with the SEET in HD were almost double (19.2 litres) the losses in CD (11.7 litres). Total calculated ion losses associated with 2 h of training in HH (3724 mmol; 115.2 g) were significantly greater when compared to CD (1413 mmol; 43.5 g). Following the SEET and a 30 min recovery period, total ion losses in CD were 3636 mmol (112.2 g) compared with 6519 mmol (200.6 g) in HD. The differences in ion losses represent the increased sweating rates stimulated by higher core temperatures during moderate to high intensity exercise in warmer ambient conditions and increases in sweat ion concentrations associated with higher sweating rates. Extracellular fluid (ECF) ion losses during daily exercise training and the SEET were also calculated from changes in plasma ion

  13. Bioanalytical devices: Technological leap for sweat sensing

    Science.gov (United States)

    Heikenfeld, Jason

    2016-01-01

    Sweat analysis is an ideal method for continuously tracking a person's physiological state, but developing devices for this is difficult. A wearable sweat monitor that measures several biomarkers is a breakthrough. See Letter p.509

  14. Testing of a sodium/nickel chloride (ZEBRA) battery for electric propulsion of ships and vehicles

    Science.gov (United States)

    Kluiters, Edwin C.; Schmal, Dick; ter Veen, Willem R.; Posthumus, Kees J. C. M.

    One of the promising future batteries for electric propulsion of vehicles and ships is the sodium/nickel chloride or ZEBRA (Zero Emission Battery Research Activities) battery. Despite some disadvantages with respect to the high temperature, the advantages with respect to specific energy and energy density are such that, especially in applications where the battery is used on a more or less continuous basis (e.g., in delivery vans and taxies) it is an interesting candidate battery. Another interesting application is on board of ships, like submarines or future electrical surface ships with electric propulsion. In 1995 a 2 year feasibility study, including experimental testing of a 10 kW h battery, was completed. This investigated the naval applicability of the sodium/sulphur battery, which is also a high temperature battery. Here the limited, experimentally proven, life-time of the batteries of about 1.5 years and this made naval application almost impossible. A paper about this study was presented at the 19th International Power Sources Symposium held at Brighton, England, in April 1995 [R.A.A. Schillemans, C.E. Kluiters, Sodium/sulphur batteries for naval applications, in: A. Attewell, T. Keily (Eds.), Power Sources 15, International Power Sources Symposium Committee, Crowborough UK, 1995. p. 421.]. Because of the more or less comparable specifications on specific energy and the more promising results of the life-time and field tests with sodium/nickel chloride batteries, a ZEBRA battery from AEG Anglo Batteries has been tested for naval applications. This was done by simulating the charge and discharge as it occurs in practice for the applications investigated. With respect to the electrical ship application (investigated for the Royal Netherlands Navy) the power versus time taken from the battery was simulated as well as the charge procedures. The same can be done for the vehicle application: in this case typical drive cycles for a van or taxi are translated to

  15. Working Up a Good Sweat - The Challenges of Standardising Sweat Collection for Metabolomics Analysis.

    Science.gov (United States)

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-02-01

    Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. A literature review of human sweat analysis over the past 10 years (2006-2016) was performed to identify studies with metabolomics or similarly applicable 'omics' analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease.

  16. Sweat Therapy Theory, Practice, and Efficacy

    Science.gov (United States)

    Eason, Allen; Colmant, Stephen; Winterowd, Carrie

    2009-01-01

    The purpose of this article is to examine the potential application of sweat rituals to group counseling, adventure therapy, and other forms of group work by describing a theoretical model for how sweat rituals work and presenting the results of a randomized comparative outcome study on the efficacy of sweat therapy. The theoretical model proposes…

  17. Human Elimination of Organochlorine Pesticides: Blood, Urine, and Sweat Study.

    Science.gov (United States)

    Genuis, Stephen J; Lane, Kevin; Birkholz, Detlef

    2016-01-01

    Background . Many individuals have been exposed to organochlorinated pesticides (OCPs) through food, water, air, dermal exposure, and/or vertical transmission. Due to enterohepatic reabsorption and affinity to adipose tissue, OCPs are not efficiently eliminated from the human body and may accrue in tissues. Many epidemiological studies demonstrate significant exposure-disease relationships suggesting OCPs can alter metabolic function and potentially lead to illness. There is limited study of interventions to facilitate OCP elimination from the human body. This study explored the efficacy of induced perspiration as a means to eliminate OCPs. Methods . Blood, urine, and sweat (BUS) were collected from 20 individuals. Analysis of 23 OCPs was performed using dual-column gas chromatography with electron-capture detectors. Results . Various OCPs and metabolites, including DDT, DDE, methoxychlor, endrin, and endosulfan sulfate, were excreted into perspiration. Generally, sweat samples showed more frequent OCP detection than serum or urine analysis. Many OCPs were not readily detected in blood testing while still being excreted and identified in sweat. No direct correlation was found among OCP concentrations in the blood, urine, or sweat compartments. Conclusions . Sweat analysis may be useful in detecting some accrued OCPs not found in regular serum testing. Induced perspiration may be a viable clinical tool for eliminating some OCPs.

  18. Do elephants need to sweat?

    African Journals Online (AJOL)

    higher increase (Clifford, Kerslake & Waddell 1959). Thus a number of factors studied under laboratory condi- tions in non-sweating human skin are pertinenl to this con- sideration of evaporative waler loss froro elephant skin and we have shown that the evaporative loss could provide the heat transfer necessary for thermal ...

  19. Sweat patterns differ between tilt-induced reflex syncope and tilt-induced anxiety among youth.

    Science.gov (United States)

    Heyer, Geoffrey L; Harvey, Rebecca A; Islam, Monica P

    2016-08-01

    Profound sweating can occur with reflex-syncope and with emotional distress, but little is known about the similarities and differences between these sweat responses when they occur during orthostatic challenge. We sought to characterize and compare the sweat patterns related to tilt-induced syncope, presyncope, anxiety, and normal tilt testing. In a prospective observational study, quantitative sweat rate was measured from the abdomen, forearm, ankle, and thigh during head-upright tilt. Sweat characteristics were compared across tilt diagnoses of syncope, presyncope, anxiety, and normal testing. When anxiety and syncope/presyncope occurred during the same study (separated by ≥6 min), both were diagnosed. Our cohort comprised150 patients (15.1 ± 2.3 years; 82.9 % female) with 156 diagnoses: 76 with reflex-syncope, 31 with presyncope, 23 with anxiety, and 26 with normal results. All syncope/presyncope patients and 20 (87 %) of the anxiety patients had corresponding sweat responses. Minimal or negligible sweating occurred among patients with normal tests. Neither basal sweat (19.4 ± 4.7 versus 18.3 ± 3.7 versus 18.5 ± 3.7 nL/min/cm(2)) nor peak sweat (171 ± 47.4 versus 149.4 ± 64.4 versus 154.4 ± 59.2 nL/min/cm(2)) differed between patients with syncope, presyncope, or anxiety, p = .32 and p = .12, respectively. However, the qualitative sweat patterns related to syncope/presyncope (diffuse, smoothly contoured, symmetrical, single peaks) differed considerably from the sweat patterns related to anxiety (heterogeneous, asymmetrical, roughly contoured single-peak, multi-peak, or progressive sweat changes). The sweat patterns related to syncope/presyncope are distinguishable from the sweat patterns related to anxiety. Recognition of the different sweat patterns can inform how signs and symptoms are interpreted during clinical orthostatic challenge.

  20. Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes.

    Science.gov (United States)

    Rose, Daniel P; Ratterman, Michael E; Griffin, Daniel K; Hou, Linlin; Kelley-Loughnane, Nancy; Naik, Rajesh R; Hagen, Joshua A; Papautsky, Ian; Heikenfeld, Jason C

    2015-06-01

    Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.

  1. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans

    Science.gov (United States)

    2013-01-01

    Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6–2.3 L, with the hands (80–160 g.h−1) and feet (50–150 g.h−1) losing the most, the head and neck losing intermediate amounts (40–75 g.h−1) and all remaining sites losing 15–60 g.h−1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm−2) and the lowest on the upper lip (16 glands.cm−2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min−1, the forehead (0.99 mg.cm−2.min−1), dorsal fingers (0.62 mg.cm−2.min−1) and upper back (0.59 mg.cm−2.min−1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm−2.min−1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm−2.min−1, sodium losses of 26.5–49.7 mmol.L−1 could be expected, with the corresponding chloride loss being 26.8–36.7 mmol.L−1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise. PMID:23849497

  2. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans.

    Science.gov (United States)

    Taylor, Nigel As; Machado-Moreira, Christiano A

    2013-02-01

    Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.

  3. Fungal protein MGL_1304 in sweat is an allergen for atopic dermatitis patients.

    Science.gov (United States)

    Hiragun, Takaaki; Ishii, Kaori; Hiragun, Makiko; Suzuki, Hidenori; Kan, Takanobu; Mihara, Shoji; Yanase, Yuhki; Bartels, Joachim; Schröder, Jens-M; Hide, Michihiro

    2013-09-01

    Sweat is a major aggravating factor of atopic dermatitis (AD) and approximately 80% of patients with AD show type I hypersensitivity against sweat. To identify and characterize an antigen in sweat that induces histamine release from basophils of patients with AD. Basophil histamine-releasing activity in sweat was purified by a combination of chromatographies, and proteins were analyzed with mass spectrometry. Recombinant proteins of the sweat antigen were generated, and their biological characteristics were studied by immunoblots, histamine release tests, and neutralization assays. We identified a fungal protein, MGL_1304, derived from Malassezia globosa (M globosa) in the purified sweat antigen. Recombinant MGL_1304 induced histamine release from basophils of most of the patients with AD, in accordance with the semi-purified sweat antigen. Moreover, recombinant MGL_1304 abolished the binding of serum IgE of patients with AD to the semi-purified sweat antigen, or vice versa in immunoblot analysis, and attenuated the sensitization of RBL-48 mast cells expressing human FcɛRI by serum IgE. Studies of truncated mutants of MGL_1304 indicated that IgE of patients with AD recognized the conformational structure of MGL_1304 rather than short peptide sequences. Western blot analysis of the whole lysate, the culture supernatant of M globosa, and the semi-purified sweat antigen showed that MGL_1304 was produced as a minor immunological antigen of M globosa with posttranslational modification, cleaved, and secreted as a 17-kDa major histamine-releasing sweat antigen. MGL_1304 is a major allergen in human sweat and could cause type I allergy in patients with AD. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  4. Volume and composition of hand sweat of White and Black men and women in desert walks.

    Science.gov (United States)

    Dill, D B; Yousef, M K; Goldman, A; Hillyard, S D; Davis, T P

    1983-05-01

    Many investigators have sought, but failed to find, ethnic differences in the number and regional distribution of active sweat glands. In this study measurements have been made of sweat secreted on one hand and also on the whole body of Whites and Blacks walking in desert heat. Whites numbered 31 men and 27 women, ages 30 to 88 years; there were 21 Black men and 31 Black women, ages 16 to 61 years. Each walked on three occasions for 1 hour at a rate that required an oxygen consumption of about 40% of aerobic capacity. Ambient temperature ranged from 32 to 44 degrees C in 1979 and 1980; means were 38.4 degrees C in 1979 and 36.7 degrees C in 1980. There was no sweat in the gloves of many Blacks; this was true of only a few Whites. Volume of body sweat increased in both races with rate of walking; volume of hand sweat increased more in Whites than in Blacks. The Mann-Whitney test revealed that volumes of hand sweat were significantly greater for Whites than for Blacks. It was concluded that in desert walks most Whites and few Blacks sweat freely on their hands. In samples of hand sweat, Na+, K+, and Cl- were determined. Concentrations of each ion varied widely in both races, and were unrelated to race. Concentrations of Na+ and Cl- generally are somewhat higher in hand sweat than in body sweat; concentrations of K+ are much higher. It follows that the values for concentration of Na+ and Cl- reported in Table 3 probably are somewhat higher than would have been found in body sweat, and concentrations of K+ are probably much higher.

  5. Whole body sweat collection in humans: an improved method with preliminary data on electrolyte content.

    Science.gov (United States)

    Shirreffs, S M; Maughan, R J

    1997-01-01

    Previous methods used to collect human sweat for electrolyte analysis have been criticized because they involve only regional sampling or because of methodological problems associated with whole body-washdown techniques. An improved method for collection of whole body sweat from exercising subjects is described. It involved construction of a plastic frame that supports a large plastic bag within which the subject exercises. The subject and the equipment are washed with distilled, deionized water before exercise begins. After exercise is completed, the subject and equipment are again washed with water containing a marker not present in sweat (ammonium sulfate). Total sweat loss is calculated from the change in body mass, and the volume of sweat not evaporated is calculated from dilution of the added marker. Recovery of added water was 102 +/- 2% (SD) of the added volume, and recovery of added electrolytes was 99 +/- 2% for sodium, 98 +/- 9% for potassium, and 101 +/- 4% for chloride. Repeated trials (n = 4) on five subjects to establish the reproducibility of the method gave a coefficient of variation of 17 +/- 5% for sodium, 23 +/- 6% for potassium, and 15 +/- 6% for chloride. These values include the biological variability between trials as well as the error within the method. The biological variability thus appears to be far greater than the methodological error. Normal values for the composition of sweat induced by exercise in a hot, humid environment in healthy young men and women were (in mM) 50.8 +/- 16.5 sodium, 4.8 +/- 1.6 potassium, 1.3 +/- 0.9 calcium, 0.5 +/- 0.5 magnesium, and 46.6 +/- 13.1 chloride.

  6. An Accelerated Test Method of Simultaneous Carbonation and Chloride Ion Ingress: Durability of Silica Fume Concrete in Severe Environments

    Directory of Open Access Journals (Sweden)

    S. A. Ghahari

    2016-01-01

    Full Text Available The effects of simultaneous carbonation and chloride ion attack on mechanical characteristics and durability of concrete containing silica fume have been investigated through an accelerated test method. Specimens containing different amounts of silica fume were maintained in an apparatus in which carbon dioxide pressure and concentration and relative humidity were kept constant, and wetting and drying cycles in saline water were applied. Surface resistivity, sorptivity, CO2 consumption, and carbonation and chloride ion ingress depths measurements were taken. Phase change due to carbonation and chloride ion attack was monitored by XRD analysis, and microstructures and interfacial transition zones were studied by implementing SEM as well as mercury intrusion porosimetry. It was expected to have a synergistic effect in the tidal zone where simultaneous carbonation and chloride ion attack happen. However, the observed reduced surface resistivity, compared to specimens maintained in CO2 gas, could be due to the moisture that is available near the surface, hindering CO2 from penetrating into the pores of the specimens. Moreover, the porosity analysis of the specimens showed that the sample containing silica fume cured in the tidal zone had 50.1% less total porosity than the plain cement paste cured in the same condition.

  7. Sweat as an Efficient Natural Moisturizer.

    Science.gov (United States)

    Shiohara, Tetsuo; Sato, Yohei; Komatsu, Yurie; Ushigome, Yukiko; Mizukawa, Yoshiko

    2016-01-01

    Although recent research on the pathogenesis of allergic skin diseases such as atopic dermatitis has focused on defects in skin genes important for maintaining skin barrier function, the fact that excreted sweat has an overwhelmingly great capacity to increase skin surface hydration and contains moisturizing factors has long been ignored: the increase in water loss induced by these gene defects could theoretically be compensated fully by a significant increase in sweating. In this review, the dogma postulating the detrimental role of sweat in these diseases has been challenged on the basis of recent findings on the physiological functions of sweat, newly recognized sweat gland-/duct-related skin diseases, and therapeutic approaches to the management of these diseases. We are now beginning to appreciate that sweat glands/ducts are a sophisticated regulatory system. Furthermore, depending on their anatomical location and the degree of the impairment, this system might have a different function: sweating responses in sweat glands/ducts located at the folds in hairy skin such as on the trunk and extremities could function as natural regulators that maintain skin hydration under quiescent basal conditions, in addition to the better-studied thermoregulatory functions, which can be mainly mediated by those at the ridges. The normal functioning of sweat could be disturbed in various inflammatory skin diseases. Thus, we should recognize sweating disturbance as an etiologic factor in the development of these diseases. © 2016 S. Karger AG, Basel.

  8. Urea transporters and sweat response to uremia.

    Science.gov (United States)

    Keller, Raymond W; Bailey, James L; Wang, Yanhua; Klein, Janet D; Sands, Jeff M

    2016-06-01

    In humans, urea is excreted in sweat, largely through the eccrine sweat gland. The urea concentration in human sweat is elevated when compared to blood urea nitrogen. The sweat urea nitrogen (UN) of patients with end-stage kidney disease (ESRD) is increased when compared with healthy humans. The ability to produce sweat is maintained in the overwhelming majority of ESRD patients. A comprehensive literature review found no reports of sweat UN neither in healthy rodents nor in rodent models of chronic kidney disease (CKD). Therefore, this study measured sweat UN concentrations in healthy and uremic rats. Uninephrectomy followed by renal artery ligation was used to remove 5/6 of renal function. Rats were then fed a high-protein diet to induce uremia. Pilocarpine was used to induce sweating. Sweat droplets were collected under oil. Sweat UN was measured with a urease assay. Serum UN was measured using a fluorescent ortho-pthalaldehyde reaction. Immunohistochemistry (IHC) was accomplished with a horseradish peroxidase and diaminobenzidine technique. Sweat UN in uremic rats was elevated greater than two times compared to healthy pair-fed controls (220 ± 17 and 91 ± 15 mmol/L, respectively). Post hoc analysis showed a significant difference between male and female uremic sweat UN (279 ± 38 and 177 ± 11 mmol/L, respectively.) IHC shows, for the first time, the presence of the urea transporters UT-B and UT-A2 in both healthy and uremic rat cutaneous structures. Future studies will use this model to elucidate how rat sweat UN and other solute excretion is altered by commonly prescribed diuretics. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  9. The detection of cortisol in human sweat: implications for measurement of cortisol in hair.

    Science.gov (United States)

    Russell, Evan; Koren, Gideon; Rieder, Michael; Van Uum, Stan H M

    2014-02-01

    Hair cortisol analysis has been shown to be an effective measure of chronic stress. Cortisol is assumed to incorporate into hair via serum, sebum, and sweat sources; however, the extent to which sweat contributes to hair cortisol content is unknown. Sweat and saliva samples were collected from 17 subjects after a period of intensive exercise and analyzed by salivary enzyme-linked immunosorbent assay (ELISA). Subsequently, an in vitro test on exposure of hair to hydrocortisone was conducted. Residual hair samples were immersed in a 50-ng/mL hydrocortisone solution for periods lasting 15 minutes to 24 hours, followed by a wash or no-wash condition. Hair cortisol content was determined using our modified protocol for a salivary ELISA. Postexercise control sweat cortisol concentrations ranged from 8.16 to 141.7 ng/mL and correlated significantly with the log-transformed time of day. Sweat cortisol levels significantly correlated with salivary cortisol concentrations. In vitro hair exposure to a 50-ng/mL hydrocortisone solution (mimicking sweat) for 60 minutes or more resulted in significantly increased hair cortisol concentrations. Washing with isopropanol did not affect immersion-increased hair cortisol concentrations. Human sweat contains cortisol in concentrations comparable with salivary cortisol levels. This study suggests that perfuse sweating after intense exercise may increase cortisol concentrations detected in hair. This increase likely cannot be effectively decreased with conventional washing procedures and should be considered carefully in studies using hair cortisol as a biomarker of chronic stress.

  10. A Review on Mutagenicity Testing for Hazard Classification of Chemicals at Work: Focusing on in vivo Micronucleus Test for Allyl Chloride

    Directory of Open Access Journals (Sweden)

    Kyung-Taek Rim

    2015-09-01

    Full Text Available Chemical mutagenicity is a major hazard that is important to workers' health. Despite the use of large amounts of allyl chloride, the available mutagenicity data for this chemical remains controversial. To clarify the mutagenicity of allyl chloride and because a micronucleus (MN test had not yet been conducted, we screened for MN induction by using male ICR mice bone marrow cells. The test results indicated that this chemical is not mutagenic under the test conditions. In this paper, the regulatory test battery and several assay combinations used to determine the genotoxic potential of chemicals in the workplace have been described. Further application of these assays may prove useful in future development strategies of hazard evaluations of industrial chemicals. This study also should help to improve the testing of this chemical by commonly used mutagenicity testing methods and investigations on the underlying mechanisms and could be applicable for workers' health.

  11. Low abundance of sweat duct Cl− channel CFTR in both healthy and cystic fibrosis athletes with exceptionally salty sweat during exercise

    Science.gov (United States)

    Haack, Karla K. V.; Pollack, Brian P.; Millard-Stafford, Mindy; McCarty, Nael A.

    2011-01-01

    To understand potential mechanisms explaining interindividual variability observed in human sweat sodium concentration ([Na+]), we investigated the relationship among [Na+] of thermoregulatory sweat, plasma membrane expression of Na+ and Cl− transport proteins in biopsied human eccrine sweat ducts, and basal levels of vasopressin (AVP) and aldosterone. Lower ductal luminal membrane expression of the Cl− channel cystic fibrosis transmembrane conductance regulator (CFTR) was observed in immunofluorescent staining of sweat glands from healthy young adults identified as exceptionally “salty sweaters” (SS) (n = 6, P sweat [Na+] (control, n = 6). Genetic testing of healthy subjects did not reveal any heterozygotes (“carriers”) for any of the 39 most common disease-causing CFTR mutations in the United States. SS had higher baseline plasma [AVP] compared with control (P = 0.029). Immunostaining to investigate a potential relationship between higher plasma [AVP] (and sweat [Na+]) and ductal membrane aquaporin-5 revealed for all groups a relatively sparse and location-dependent ductal expression of the water channel with localization primarily to the secretory coil. Availability of CFTR for NaCl transport across the ductal membrane appears related to the significant physiological variability observed in sweat salt concentration in apparently healthy humans. At present, a heritable link between healthy salty sweaters and the most prevalent disease-causing CFTR mutations cannot be established. PMID:21228336

  12. An Accelerated Test Method of Simultaneous Carbonation and Chloride Ion Ingress: Durability of Silica Fume Concrete in Severe Environments

    OpenAIRE

    Ghahari, S A; Ramezanianpour, A. M.; Ramezanianpour, A.A.; Esmaeili, M.

    2016-01-01

    The effects of simultaneous carbonation and chloride ion attack on mechanical characteristics and durability of concrete containing silica fume have been investigated through an accelerated test method. Specimens containing different amounts of silica fume were maintained in an apparatus in which carbon dioxide pressure and concentration and relative humidity were kept constant, and wetting and drying cycles in saline water were applied. Surface resistivity, sorptivity, CO2 consumption, and c...

  13. Electrical resistivity testing for as-built concrete performance assessment of chloride penetration resistance

    NARCIS (Netherlands)

    Polder, R.B.; Peelen, W.H.A.

    2014-01-01

    The electrical resistivity of concrete can provide information about its transport properties, which is relevant for durability performance. For example, resistivity is inversely proportional to chloride diffusion, at least within similar concrete compositions. A methodology is proposed for on-site

  14. Sweat sensor for sports physiological monitoring

    OpenAIRE

    Benito-Lopez, Fernando; Coyle, Shirley; Diamond, Dermot

    2011-01-01

    The fabrication and the performance of a novel, wearable, robust, flexible and disposable micro-fluidic device which incorporates miniature optical components as a detection system, for wireless monitoring in real time mode of sweat pH during an exercise session is presented. This micro-fluidic platform is completely non-invasive, providing a continuous flow of fresh sweat for continuous real time analysis, ensuring immediate feedback regarding sweat composition to an athlete and/or coach.

  15. Working Up a Good Sweat – The Challenges of Standardising Sweat Collection for Metabolomics Analysis

    Science.gov (United States)

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-01-01

    Introduction Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. Methods A literature review of human sweat analysis over the past 10 years (2006–2016) was performed to identify studies with metabolomics or similarly applicable ‘omics’ analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Results Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Conclusion Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease. PMID:28798503

  16. Stability study of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection with limit tests for impurities

    DEFF Research Database (Denmark)

    Nissen, Klaus; Bogedal Jorgensen, Lene; Lindegaard Berg, Dorthe

    2017-01-01

    Purpose. Results of an evaluation of the stability of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection are presented. Methods. Methotrexate concentrated solution (100 mg/mL) was diluted to nominal concentrations of 0.2 and 20 mg/mL in infusion bags containing 0.9% sodium...... chloride injection or 5% dextrose injection. The filled bags were stored for 28 days at 25 °C and 60% relative humidity and protected from light. Samples were withdrawn for analysis on the day of preparation and after 3, 7, 14, 21, and 28 days. The test program included visual inspections, measurements...... in amounts of known and unknown degradation products were detected. In 5% dextrose injection, methotrexate at the higher concentration was stable for 28 days, with minor formation of degradation products; in the 0.2-mg/mL solution, however, methotrexate was stable for only 3 days. At later time points...

  17. Indirect measurements of sweat electrolyte concentration in the laboratory diagnosis of cystic fibrosis

    Science.gov (United States)

    Heeley, M.; Woolf, D.; Heeley, A.

    2000-01-01

    AIM—To investigate whether analytical methods based on the colligative physical chemical properties of ions or solutes in sweat are less effective than the specific measurement of electrolytes in the diagnosis of cystic fibrosis (CF).
METHODS—A single sweat sample was collected (Macroduct) from each of 211 infants and children, of whom 57 had CF, for the measurment of sodium, chloride, osmolality, and conductivity.
RESULTS—The ranges within which CF and non-CF individual values overlapped (equivocal ranges), were wider for sodium and osmolality measurement than for chloride or conductivity. Neither of the latter two measurements provided a discriminatory advantage over the other. The utilisation of broadly based age related ranges for non-CF control subjects served to improve the discriminatory power of all four measurements to an extent that, in this cohort, both chloride and conductivity provided complete discrimination.
CONCLUSION—Sweat conductivity is as effective as chloride measurement in the laboratory diagnosis of CF.

 PMID:10799439

  18. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    Science.gov (United States)

    Dunstan, R Hugh; Sparkes, Diane L; Dascombe, Benjamin J; Macdonald, Margaret M; Evans, Craig A; Stevens, Christopher J; Crompton, Marcus J; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine

  19. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    Directory of Open Access Journals (Sweden)

    R Hugh Dunstan

    Full Text Available Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine

  20. Precise measurement of instantaneous volume of eccrine sweat gland in mental sweating by optical coherence tomography

    Science.gov (United States)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-03-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). We propose a method for extraction of the target eccrine sweat gland by use of the connected component extraction process and the adaptive threshold method, where the en-face OCT images are constructed by the SS-OCT. Furthermore, we demonstrate precise measurement of instantaneous volume of the sweat gland in response to the external stimulus. The dynamic change of instantaneous volume of eccrine sweat gland in mental sweating is performed by this method during the period of 300 sec with the frame intervals of 3.23 sec.

  1. Sweat rate and sweat electrolyte composition in international female soccer players during game specific training.

    Science.gov (United States)

    Kilding, A E; Tunstall, H; Wraith, E; Good, M; Gammon, C; Smith, C

    2009-06-01

    The purpose of this study was to determine the sweat rate and sweat electrolyte composition in female international level soccer players. Thirteen soccer players performed two 90 min soccer-specific training sessions (T1 and T2) on separate days. Hydration status was determined prior to each session and sweat loss, sweat rate and sweat composition (Na (+), K (+), Mg (++) and Ca (+)) were determined from patches worn during training. The mean sweat rate during T1 and T2 was 0.50+/-0.20 and 0.43+/-0.18 L.h (-1) respectively (P>0.05). The mean sweat electrolyte composition during T1 and T2 was: [Na (+)]: 43.9+/-15.0 and 46.2+/-7.9 mmol.L (-1); [K (+)]: 6.1+/-1.1 and 5.2+/-1.1 mmol.L (-1); [Mg (++)]: 0.1+/-0.0 and 0.1+/-0.0 mmol.L (-1); [Ca (+)]: 1.2+/-0.5 and 0.7+/-0.1 mmol.L (-1), respectively. When data from T1 and T2 were combined, there were no relationships between sweat rate and sweat concentration of any electrolyte. In conclusion, the sweat rate and sweat electrolyte losses in this cohort of international female soccer players, during soccer-specific training in cool conditions, were small. Electrolyte losses of this magnitude are unlikely to require special consideration in terms of optimising player hydration.

  2. Sweating Like a Pig: Physics or Irony?

    Science.gov (United States)

    Bohren, Craig F.

    2016-01-01

    In his interesting and informative book "Is That a Fact?," Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on…

  3. Tellurite glass as a waste form for mixed alkali-chloride waste streams: Candidate materials selection and initial testing

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Brian J., E-mail: brian.riley@pnnl.gov [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Rieck, Bennett T. [Washington State University, Pullman, WA 99164 (United States); McCloy, John S.; Crum, Jarrod V. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Sundaram, S.K. [Alfred University, Alfred, NY 14802 (United States); Vienna, John D. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States)

    2012-05-15

    Highlights: Black-Right-Pointing-Pointer We provide the first standardized chemical durability test on tellurite glasses. Black-Right-Pointing-Pointer The glasses we studied showed a wide variety of chemical durability. Black-Right-Pointing-Pointer The best-performing glass showed good halide retention following melting and durability testing. Black-Right-Pointing-Pointer These glasses have very high densities resulting in high volumetric waste loading ability. - Abstract: Tellurite glasses have historically been shown to host large concentrations of halides. They are here considered for the first time as a waste form for immobilizing chloride wastes, such as may be generated in the proposed molten alkali salt electrochemical separations step in nuclear fuel reprocessing. Key properties of several tellurite glasses are determined to assess acceptability as a chloride waste form. TeO{sub 2} glasses with other oxides (PbO, Al{sub 2}O{sub 3} + B{sub 2}O{sub 3}, WO{sub 3}, P{sub 2}O{sub 5}, or ZnO) were fabricated with and without 10 mass% of a simulated (non-radioactive) mixed alkali, alkaline-earth, and rare earth chloride waste. Measured chemical durability is compared for the glasses, as determined by the product consistency test (PCT), a common standardized chemical durability test often used to validate borosilicate glass waste forms. The glass with the most promise as a waste form is the TeO{sub 2}-PbO system, as it offers good halide retention, a low sodium release (by PCT) comparable with high-level waste silicate glass waste forms, and a high storage density.

  4. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study

    OpenAIRE

    Kaneko, Sakae; Murota, Hiroyuki; Murata, Susumu; Katayama, Ichiro; Morita, Eishin

    2017-01-01

    Background. Sweat is an aggravating factor in atopic dermatitis (AD), regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy’s involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years) to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine rele...

  5. Standard test method for evaluating stress-corrosion cracking of stainless alloys with different nickel content in boiling acidified sodium chloride solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method describes a procedure for conducting stress-corrosion cracking tests in an acidified boiling sodium chloride solution. This test method is performed in 25% (by mass ) sodium chloride acidified to pH 1.5 with phosphoric acid. This test method is concerned primarily with the test solution and glassware, although a specific style of U-bend test specimen is suggested. 1.2 This test method is designed to provide better correlation with chemical process industry experience for stainless steels than the more severe boiling magnesium chloride test of Practice G36. Some stainless steels which have provided satisfactory service in many environments readily crack in Practice G36, but have not cracked during interlaboratory testing using this sodium chloride test method. 1.3 This boiling sodium chloride test method was used in an interlaboratory test program to evaluate wrought stainless steels, including duplex (ferrite-austenite) stainless and an alloy with up to about 33% nickel. It may also b...

  6. PIXE analysis of cystic fibrosis sweat samples with an external proton beam

    Science.gov (United States)

    Sommer, F.; Massonnet, B.

    1987-03-01

    PIXE analysis with an external proton beam is used to study, in four control and five cystic fibrosis children, the elemental composition of sweat samples collected from different parts of the body during entire body hyperthermia. We observe no significant difference of sweat rates and of temperature variations between the two groups during sweat test. The statistical study of results obtained by PIXE analysis allows us to pick out amongst 8 elements studied, 6 elements (Na, Cl, Ca, Mn, Cu, Br) significatively different between the two groups of subjects. Using regression analysis, Na, Cl and Br concentrations could be used in a predictive equation of the state of health.

  7. [Cholinergic urticaria successfully treated by immunotherapy with partially purified sweat antigen].

    Science.gov (United States)

    Tanaka, Toshihiko; Ishii, Kaori; Suzuki, Hidenori; Kameyoshi, Yoshikazu; Hide, Michihiro

    2007-01-01

    A 24-years-old man was referred to our University Hospital because of one and a half-year history of disabling symptoms related to physical exertion. Multiple small round-shaped wheals with severe itch were induced by exercise, warmth and psychological stress. These symptoms were resistant to histamine H1-receptor antagonists. Similar eruptions were induced by sauna-bathing, and skin test with autologous sweat showed a flare and wheal reaction. Incubation of his peripheral-blood leukocytes with partially purified sweat antigen evoked marked histamine release, indicating that he has been IgE-sensitized to an antigen(s) in human sweat. Specific immunotherapy using partially purified sweat antigen was performed every other week. Both pruritus and wheals improved gradually, and the reactivity of his peripheral blood leukocytes against sweat antigen decreased as immunotherapy was proceeded. Specific immunotherapy using sweat antigen may be valuable for patients with cholinergic urticaria with type I hypersensitivity to sweat antigen(s).

  8. Transition duration of ingested deuterium oxide to eccrine sweat during exercise in the heat.

    Science.gov (United States)

    Church, Adam; Lee, Fanny; Buono, Michael J

    2017-01-01

    The time necessary for the initial appearance of ingested water as sweat during exercise in the heat remains unknown. Based on the current literature, we estimated fluid transition through the body, from ingestion to appearance as sweat, to have a minimum time duration of approximately three minutes. The purpose of this study was to test this prediction and identify the time necessary for the initial enrichment of deuterium oxide (D2O) in sweat following ingestion during exercise in the heat. Eight participants performed moderate intensity (40% of maximal oxygen uptake) treadmill exercise in an environmental chamber (40°C, 40% rH) to induce active sweating. After fifteen minutes, while continuing to walk, participants consumed D2O (0.15mlkg-1) in a final volume of 50ml water. Scapular sweat samples were collected one minute prior to and ten minutes post-ingestion. Samples were analyzed for sweat D2O concentration using isotope ratio mass spectrometry and compared to baseline. Mean±SD ∆ sweat D2O concentration at minutes one and two post-ingestion were not significantly higher than baseline (0min). Minutes three (9±3ppm) through ten (23±11ppm) post-ingestion had ∆ sweat D2O concentrations significantly (P<0.05) higher than baseline. Such results suggest that ingested water rapidly transports across the mucosal membrane of the alimentary canal into the vasculature space, enters the extravascular fluid, and is actively secreted by the eccrine sweat glands onto the surface of the skin for potential evaporation in as little as three minutes during exercise in the heat. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. System-level design of an RFID sweat electrolyte sensor patch.

    Science.gov (United States)

    Rose, Daniel P; Ratterman, M; Griffin, Daniel K; Hou, Linlin; Kelley-Loughnane, Nancy; Naik, Rajesh K; Hagen, Joshua A; Papautsky, I; Heikenfeld, Jason

    2014-01-01

    Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive RFID sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of mM ionic solutes in sweat, and surface temperature, as read by an Android smart-phone app (in-vitro tests).

  10. Pilocarpine iontophoresis test

    DEFF Research Database (Denmark)

    Hjortskov, N; Jepsen, Leif; Nielsen, B

    1995-01-01

    The pilocarpine iontophoresis test (P-test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P-test reflects whole-body and regional sweat secretion...... during exercise in the heat. Finally, we determined whether the P-test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone-deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion......-to-day variation of 20.8% between individual subjects. There was a significant positive correlation between the P-test and regional sweat secretion (r2 = 0.74). The correlation coefficient (r2) was 0.50 for the correlation between the P-test and whole-body sweat secretion, and 0.52 for the correlation between...

  11. Precise measurement of volume of eccrine sweat gland in mental sweating by optical coherence tomography

    Science.gov (United States)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-04-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). In this paper, we propose a method for extraction of the specific eccrine sweat gland by means of the connected component extraction process and the adaptive threshold method, where the en face OCT images are constructed by the swept-source OCT. In the experiment, we demonstrate precise measurement of the volume of the sweat gland in response to the external stimulus.

  12. In Vivo Readout of CFTR Function: Ratiometric Measurement of CFTR-Dependent Secretion by Individual, Identifiable Human Sweat Glands

    Science.gov (United States)

    Wine, Jeffrey J.; Char, Jessica E.; Chen, Jonathan; Cho, Hyung-ju; Dunn, Colleen; Frisbee, Eric; Joo, Nam Soo; Milla, Carlos; Modlin, Sara E.; Park, Il-Ho; Thomas, Ewart A. C.; Tran, Kim V.; Verma, Rohan; Wolfe, Marlene H.

    2013-01-01

    To assess CFTR function in vivo, we developed a bioassay that monitors and compares CFTR-dependent and CFTR-independent sweat secretion in parallel for multiple (∼50) individual, identified glands in each subject. Sweating was stimulated by intradermally injected agonists and quantified by optically measuring spherical sweat bubbles in an oil-layer that contained dispersed, water soluble dye particles that partitioned into the sweat bubbles, making them highly visible. CFTR-independent secretion (M-sweat) was stimulated with methacholine, which binds to muscarinic receptors and elevates cytosolic calcium. CFTR-dependent secretion (C-sweat) was stimulated with a β-adrenergic cocktail that elevates cytosolic cAMP while blocking muscarinic receptors. A C-sweat/M-sweat ratio was determined on a gland-by-gland basis to compensate for differences unrelated to CFTR function, such as gland size. The average ratio provides an approximately linear readout of CFTR function: the heterozygote ratio is ∼0.5 the control ratio and for CF subjects the ratio is zero. During assay development, we measured C/M ratios in 6 healthy controls, 4 CF heterozygotes, 18 CF subjects and 4 subjects with ‘CFTR-related’ conditions. The assay discriminated all groups clearly. It also revealed consistent differences in the C/M ratio among subjects within groups. We hypothesize that these differences reflect, at least in part, levels of CFTR expression, which are known to vary widely. When C-sweat rates become very low the C/M ratio also tended to decrease; we hypothesize that this nonlinearity reflects ductal fluid absorption. We also discovered that M-sweating potentiates the subsequent C-sweat response. We then used potentiation as a surrogate for drugs that can increase CFTR-dependent secretion. This bioassay provides an additional method for assessing CFTR function in vivo, and is well suited for within-subject tests of systemic, CFTR-directed therapeutics. PMID:24204751

  13. Recent Developments in Sweat Analysis and Its Applications

    Directory of Open Access Journals (Sweden)

    Saima Jadoon

    2015-01-01

    Full Text Available Currently, the clinical use of sweat as biofluid is limited. The collection of sweat and its analysis for determining ethanol, drugs, ions, and metals have been encompassed in this review article to assess the merits of sweat compared to other biofluids, for example, blood or urine. Moreover, sweat comprises various biomarkers of different diseases including cystic fibrosis and diabetes. Additionally, the normalization of sampled volume of sweat is also necessary for getting efficient and useful results.

  14. Evolution: plastic sociality in a sweat bee.

    Science.gov (United States)

    Chapuisat, Michel

    2010-11-23

    How and why do bees become social? A transplant experiment shows that sweat bees can adopt a solitary or social lifestyle in response to their environment. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. 7 CFR 29.3554 - Sweating.

    Science.gov (United States)

    2010-01-01

    ... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  16. 7 CFR 29.3553 - Sweated.

    Science.gov (United States)

    2010-01-01

    ... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  17. Body Odor Trait Disgust Sensitivity Predicts Perception of Sweat Biosamples.

    Science.gov (United States)

    Liuzza, Marco Tullio; Olofsson, Jonas K; Sabiniewicz, Agnieszka; Sorokowska, Agnieszka

    2017-07-01

    Body odors are potent triggers of disgust and regulate social behaviors in many species. The role of olfaction in disgust-associated behaviors has received scant attention in the research literature, in part because olfactory disgust assessments have required laboratory testing with odors. We have devised the "Body Odor Disgust Scale" (BODS) to facilitate research on olfactory disgust. In this study, we evaluated whether individual differences in BODS scores would be associated with the perception of disgust for sweat samples in a laboratory setting. Results show that BODS was a strong predictor of disgust ratings of sweat samples even when controlling for general disgust sensitivity. In contrast, odor intensity ratings were unrelated to BODS scores. Our findings suggest that the BODS scores reflect body odor disgust perception. The BODS scale might facilitate research on olfactory disgust responses and associated behaviors. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Sodium chloride as a reference substance for the three growth endpoints used in the Lemna minor L. (1753 test

    Directory of Open Access Journals (Sweden)

    Aline Andrade Godoy

    2017-01-01

    Full Text Available Lemna sp. growth inhibition test standardized protocols suggest the use of compounds such as 3,5-dichlorophenol as reference substances for checking the test organism’s sensitivity routinely. However, this and other recommended chemicals present risks to human health and to the environment. Sodium chloride (NaCl appears as a less toxic alternative reference substance which has been successfully used in routine ecotoxicological tests. However, the evaluation of this compound in multiple growth endpoints used in the L. minor test, which is required for recommending it as a reference substance for this test organism, has not yet been reported. In the present study, NaCl was tested with L. minor for the growth endpoints frond number, total frond area and fresh weight. Results showed acceptable sensitivity and reproducibility (coefficient of variance < 15.0% for all three of the measured endpoints. Statistically significant differences were observed between the EC50 values calculated based on the three endpoints (p < 0.05. Total frond area was the most sensitive one, with average EC50 value of 2742.80 ± 245.7 mg L-1. It was anticipated that NaCl can be a suitable alternative reference substance and that total frond area should be the endpoint of choice for sensitivity toxicity tests using NaCl.

  19. Sweating Like a Pig: Physics or Irony?

    Science.gov (United States)

    Bohren, Craig F.

    2016-03-01

    In his interesting and informative book Is That a Fact?, Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on the "pig." But this explanation, which I have seen on the Internet, lacks a few caveats. It implies that molten iron, solidifying and cooling, anywhere, anytime, accretes liquid water, as if this were a special property of cooling iron. Set aside that real pigs sweat perceptibly from their snouts; kiss a pig and verify for yourself. Pigs also sweat imperceptibly. Imperceptible (insensible) perspiration is water vapor from the skin and lungs exuded without sensible condensation. That from humans is about 1 liter/day. Sweat is 99% liquid water, NaCl the dominant solute, secreted quickly, sometimes profusely, by subcutaneous sweat glands in response to thermal stress, in contrast to the slow, continuous diffusion of water vapor through skin.

  20. Changes in the index of sweat ion concentration with increasing sweat during passive heat stress in humans.

    Science.gov (United States)

    Shamsuddin, A K M; Yanagimoto, S; Kuwahara, T; Zhang, Y; Nomura, C; Kondo, N

    2005-06-01

    To investigate the pattern changes in the index of sweat ion concentration at skin surface with increasing sweat during passive heat stress in humans, we measured conductivity of the perfused water with sweat as the index of sweat ion concentration and sweat rate, continuously at the chest skin surface. Eight healthy subjects (22.4 +/-1.0 years) were passively heated by lower-leg immersion in a hot water bath of 42 degrees C for 50 min in an ambient temperature of 28 degrees C and relative humidity of 50%. The internal temperature (Tor) thresholds of sweat rate and index of sweat ion concentration were almost similar. Concomitant onset for the index of sweat ion concentration and sweat rate occurred but two types of linear regression lines were identified in the relationship between the index of sweat ion concentration and sweat rate at a boundary sweat rate value of 0.30 +/- 0.08 mg cm(-2) min(-1). The slope of the regression line at low levels of sweat (slope 0.02 +/- 0.01 V mg(-1) cm(-2) min(-1)) was significantly gradual compared with that at moderate levels of sweat (slope 0.30 +/- 0.08 V mg(-1) cm(-2) min(-1)) (P<0.05). These results suggest that at low levels of sweat the index of sweat ion concentration responds gradually with respect to sweat rate, which may be due to the ion reabsorption capacity of the sweat duct, and then the index of sweat ion concentration increased steeply with sweat rate.

  1. Antimicrobial filtration with electrospun poly(vinyl alcohol) nanofibers containing benzyl triethylammonium chloride: Immersion, leaching, toxicity, and filtration tests.

    Science.gov (United States)

    Park, Jeong-Ann; Kim, Song-Bae

    2017-01-01

    Antimicrobial electrospun poly(vinyl alcohol) (PVA) nanofibers were synthesized by impregnating benzyl triethylammonium chloride (BTEAC) as an antimicrobial agent into PVA nanofibers. The BTEAC-PVA nanofibers were heat-methanol treated during the preparation for various tests. The BTEAC-PVA nanofibers became more hydrophilic than the PVA nanofibers due to incorporation of BTEAC. Through heat-methanol treatment, thermal property, crystallinity, and water stability of BTEAC-PVA nanofibers were improved considerably. The immersion test shows that heat-methanol treatment has an advantage over heat treatment to maintain BTEAC content in BTEAC-PVA nanofibers. The acute toxicity test demonstrates that the 24-h EC50 and 48-h EC50 values (EC50 = median effective concentration) of BTEAC to Daphnia magna were 113 and 90 mg/L, respectively. The leaching test indicates that the BTEAC concentration leached from BTEAC-PVA nanofibers was far below the concentration affecting the immobilization of D. magna. For antimicrobial filtration tests, the BTEAC-PVA nanofibers were deposited onto glass fiber filter. The antimicrobial filtration test was conducted against bacteria (Escherichia coli, Staphylococcus aureus) and bacteriophages (MS2, PhiX174), demonstrating that the BTEAC-PVA nanofibers could enhance the removal of E. coli and S. aureus considerably but not the removal of MS2 and PhiX174 under dynamic flow conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Sweat composition in Arabian horses performing endurance exercise on forage-based, low Na rations.

    Science.gov (United States)

    Spooner, H S; Nielsen, B D; Schott, H C; Harris, P A

    2010-11-01

    Excessive sweat loss during endurance exercise may lead to electrolyte disturbances and previous research suggests dietary factors may affect hydration status. While investigating the effect of dietary fibre type on hydration status, sweat samples were collected which allowed for the evaluation of sweat composition in horses consuming forage-based, low sodium (Na) rations. To investigate sweat composition in Arabian horses performing endurance type exercise while fed forage-based, rations low in Na. Six 2-year-old Arabian horses were fed, according to a replicated 3 × 3 Latin square, either grass hay (G), 50:50 grass hay:alfalfa hay (GA), or 50:50 grass hay: chopped fibres (GM) without any additional electrolyte supplementation. After 14 days on each diet, horses performed a 60 km treadmill exercise test. Sweat was collected from sealed pouches on the dorsal thorax after each of four 15 km exercise bouts. Intake (g/day) of Na (2.5 ± 0.4), Cl (72 ± 16), and Mg (18 ± 3) were not different between diets but K and Ca intakes (g/day) were greater (P sweat pH (7.65 ± 0.04) or concentrations (mmol/l) of K (46 ± 3), Cl (133 ± 7), Ca (8.5 ± 1.1), or Mg (2.3 ± 0.3); yet diet did influence sweat Na concentration (P sweat constituents due to diet were observed, but more importantly both Na and Cl concentration are lower than those previously reported perhaps due to low dietary Na intake or breed of animal. © 2010 EVJ Ltd.

  3. Association between pulse wave velocity and hot flashes/sweats in middle-aged women.

    Science.gov (United States)

    Yang, Ruwei; Zhou, Yang; Li, Changbin; Tao, Minfang

    2017-10-23

    As women age and go through menopause, they suffer a higher incidence of cardiovascular morbidity and mortality. Previous studies have shown that a relationship exists between hot flashes/sweats and an increased risk of cardiovascular disease. However, the association between hot flashes/sweats and arterial stiffness is unclear. We aim to explore the relationship between hot flashes/sweats and arterial stiffness using the modified Kupperman index (KMI) questionnaire and measure the brachial-ankle pulse wave velocity (baPWV). The prevalence of hot flashes in our research was reported to be 41.77%. There was a statistically significant difference between the mean baPWV among groups that experienced different severities of hot flashes/sweats according to one-way ANOVA test (p hot flashes/sweats based on linear regression after adjusting for established cardiovascular confounders (95% CI: (5.86, 43.23), p = 0.01). To the best of our knowledge, this study is the first investigation to propose that baPWV may serve both as an objective index for evaluating the severity of hot flashes/sweats and as a predictor of arterial stiffness beyond Cardiac Vascular Disease (CVD) risk factors in middle-aged women.

  4. Higher sweating rate and skin blood flow during the luteal phase of the menstrual cycle.

    Science.gov (United States)

    Lee, Haneul; Petrofsky, Jerrold; Shah, Nirali; Awali, Abdulaziz; Shah, Karan; Alotaibi, Mohammed; Yim, JongEun

    2014-10-01

    Evaporation by sweating is the most effective way to remove heat from the body. Sweat rates increase under both local and whole-body heat stress. Men and women differ in how they respond to heat, because sexual steroids alter resting body core temperature and the threshold for sweating and skin blood flow (SBF) during heating. The purpose of the present study was to compare local sweat rates and cutaneous vasodilatation during heat exposure in women with a regular menstrual cycle. The cutaneous vasodilatation was judged by measuring the SBF. Eight female and nine male subjects participated in this study, and their age range was 24-29 years. Female subjects were tested twice throughout one full menstrual cycle: once during the middle follicular phases and once during the luteal phase. Subjects remained in a temperature-regulated room at 41°C and 21% of relative humidity for 40 minutes. Sweat rate was recorded from the forehead, forearm, and thigh, and skin temperature and SBF were measured on the thigh and forehead. We found that the sweating rate and SBF were greater in the luteal phase compared to follicular phase (p0.05). We propose the enhanced sympathetic activity in the luteal phase with a regular menstrual cycle.

  5. Sweating the small stuff: Glycoproteins in human sweat and their unexplored potential for microbial adhesion.

    Science.gov (United States)

    Peterson, Robyn A; Gueniche, Audrey; Adam de Beaumais, Ségolène; Breton, Lionel; Dalko-Csiba, Maria; Packer, Nicolle H

    2016-03-01

    There is increasing evidence that secretory fluids such as tears, saliva and milk play an important role in protecting the human body from infection via a washing mechanism involving glycan-mediated adhesion of potential pathogens to secretory glycoproteins. Interaction of sweat with bacteria is well established as the cause of sweat-associated malodor. However, the role of sweat glycoproteins in microbial attachment has received little, if any, research interest in the past. In this review, we demonstrate how recent published studies involving high-throughput proteomic analysis have inadvertently, and fortuitously, exposed an abundance of glycoproteins in sweat, many of which have also been identified in other secretory fluids. We bring together research demonstrating microbial adhesion to these secretory glycoproteins in tears, saliva and milk and suggest a similar role of the sweat glycoproteins in mediating microbial attachment to sweat and/or skin. The contribution of glycan-mediated microbial adhesion to sweat glycoproteins, and the associated impact on sweat derived malodor and pathogenic skin infections are unchartered new research areas that we are beginning to explore. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Non-invasive Pregnancy Diagnosis from Urine by the Cuboni Reaction and the Barium Chloride Test in Donkeys (Equus asinus) and Alpacas (Vicugna pacos).

    Science.gov (United States)

    Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L

    2016-09-01

    The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.

  7. Prevention of pruritus with ethyl-chloride in skin prick test: a double-blind placebo-controlled prospective study.

    Science.gov (United States)

    Gal-Oz, Amir; Kivity, Shmuel; Shacham, Yacov; Fiszer, Elisheva; Rogowsky, Ori; Chernin, Gil

    2015-01-01

    Ethyl-chloride (EC) spray was recently shown to be an effective antipruritic agent, when given 15 min after histamine skin-prick test (SPT), without changing the wheal and flare reaction. We aimed to investigate the antipruritic effect of EC on SPT, when given prior to SPT. A double-blind placebo-controlled prospective study. Overall, 44 volunteers underwent histamine SPT on both arms to trigger local pruritus. Prior to test, they were randomly treated with EC spray on one arm and saline spray (placebo) on the other. Subjects as well as researchers were blinded to the type of applied sprays. The wheal and flare reaction was measured after the SPT and subjects reported the intensity of pruritus following EC/placebo using a validated pruritus questionnaire (indexes 1-3) and a visual analog scale (VAS). Significant improvement in pruritus was reported following treatment with EC compared with placebo for all four studied parameters. Index 1 in EC 3.7 ± 2.3 versus 5 ± 3.5 (p = 0.007) in placebo, index 2 in EC 2.6 ± 2.1 versus 3.8 ± 2.8 (p = 0.002) in placebo, index 3 of EC 6.3 ± 3.8 versus 8.8 ± 5.8 (p = 0.03) and VAS in EC 3.7 ± 1.9 versus 4.4 ± 2.3 (p = 0.003). There were no significant differences between EC and placebo in terms of the wheal and flare indurations area. Ethyl-chloride has an effective antipruritic agent, when given before histamine SPT. Its use did not change the wheal and flare reaction, making it ideal for prevention of pruritus, secondary to allergy skin test, without masking the results.

  8. Variability of measurements of sweat sodium using the regional absorbent-patch method.

    Science.gov (United States)

    Dziedzic, Christine E; Ross, Megan L; Slater, Gary J; Burke, Louise M

    2014-09-01

    There is interest in including recommendations for the replacement of the sodium lost in sweat in individualized hydration plans for athletes. Although the regional absorbent-patch method provides a practical approach to measuring sweat sodium losses in field conditions, there is a need to understand the variability of estimates associated with this technique. Sweat samples were collected from the forearms, chest, scapula, and thigh of 12 cyclists during 2 standardized cycling time trials in the heat and 2 in temperate conditions. Single measure analysis of sodium concentration was conducted immediately by ion-selective electrodes (ISE). A subset of 30 samples was frozen for reanalysis of sodium concentration using ISE, flame photometry (FP), and conductivity (SC). Sweat samples collected in hot conditions produced higher sweat sodium concentrations than those from the temperate environment (P = .0032). A significant difference (P = .0048) in estimates of sweat sodium concentration was evident when calculated from the forearm average (mean ± 95% CL; 64 ± 12 mmol/L) compared with using a 4-site equation (70 ± 12 mmol/L). There was a high correlation between the values produced using different analytical techniques (r2 = .95), but mean values were different between treatments (frozen FP, frozen SC > immediate ISE > frozen ISE; P sweat sodium concentration estimates differed depending on the number of sites included in the calculation. Environmental testing conditions should be considered in the interpretation of results. The impact of sample freezing and subsequent analytical technique was small but statistically significant. Nevertheless, when undertaken using a standardized protocol, the regional absorbent-patch method appears to be a relatively robust field test.

  9. Hydrochromic Approaches to Mapping Human Sweat Pores.

    Science.gov (United States)

    Park, Dong-Hoon; Park, Bum Jun; Kim, Jong-Man

    2016-06-21

    Hydrochromic materials, which undergo changes in their light absorption and/or emission properties in response to water, have been extensively investigated as humidity sensors. Recent advances in the design of these materials have led to novel applications, including monitoring the water content of organic solvents, water-jet-based rewritable printing on paper, and hydrochromic mapping of human sweat pores. Our interest in this area has focused on the design of hydrochromic materials for human sweat pore mapping. We recognized that materials appropriate for this purpose must have balanced sensitivities to water. Specifically, while they should not undergo light absorption and/or emission transitions under ambient moisture conditions, the materials must have sufficiently high hydrochromic sensitivities that they display responses to water secreted from human sweat pores. In this Account, we describe investigations that we have carried out to develop hydrochromic substances that are suitable for human sweat pore mapping. Polydiacetylenes (PDAs) have been extensively investigated as sensor matrices because of their stimulus-responsive color change property. We found that incorporation of headgroups composed of hygroscopic ions such as cesium or rubidium and carboxylate counterions enables PDAs to undergo a blue-to-red colorimetric transition as well as a fluorescence turn-on response to water. Very intriguingly, the small quantities of water secreted from human sweat pores were found to be sufficient to trigger fluorescence turn-on responses of the hydrochromic PDAs, allowing precise mapping of human sweat pores. Since the hygroscopic ion-containing PDAs developed in the initial stage display a colorimetric transition under ambient conditions that exist during humid summer periods, a new system was designed. A PDA containing an imidazolium ion was found to be stable under all ambient conditions and showed temperature-dependent hydrochromism corresponding to a

  10. Surface contamination artificially elevates initial sweat mineral concentrations

    Science.gov (United States)

    During exercise in the heat, sweat is initially concentrated in minerals, but serial sweat samples appear more dilute. Possible causes include reduced dermal mineral concentrations or flushing of surface contamination. PURPOSE: To simultaneously sample mineral concentrations in transdermal fluid (T...

  11. Prediction of Water Requirements to Replace Sweat Losses

    Science.gov (United States)

    2010-10-01

    RTO-MP-HFM-202 P6 - 1 Prediction of Water Requirements to Replace Sweat Losses Samuel N. Cheuvront, Ph.D., Richard R. Gonzalez, Ph.D...3. DATES COVERED - 4. TITLE AND SUBTITLE Prediction of Water Requirements to Replace Sweat Losses 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Prediction of Water Requirements to Replace Sweat Losses P6 - 2 RTO-MP-HFM-202 Conclusion OSEC and PW provide for more accurate sweat

  12. Rapid chloride permeability test as durability index of the concrete structure

    Directory of Open Access Journals (Sweden)

    Martínez-Sánchez, B.

    2003-12-01

    Full Text Available From the RCPT publication, this test has been frequently used in the concrete structures durability assessment. This test it could be determined in a relatively short time the material permeability, within a rank or quality level that allows comparing concretes as far as their characteristics. In this document, is present an intense investigation to evaluate mix designs with the principal objective to measure the participation and contribution of the components that take part in the concrete manufacture. A detailed review of the components contribution is applied to know specifically the properties in the product during any state: fresh or hard path. In this paper, are identified and included the most influence variables in the concrete properties modification.

    Desde su lanzamiento, la prueba de permeabilidad rápida a la penetración de cloruros ha sido usada frecuentemente en la evaluación de la durabilidad en las estructuras de hormigón, ya que se puede establecer, en un tiempo relativamente corto, la determinación de la permeabilidad del material, dentro de un nivel de calidad que permite comparar hormigones en cuanto a esta característica. En este articulo se presenta una investigación en donde se evalúan diseños de mezcla con la finalidad de medir la participación y contribución de cada uno de los componentes que intervienen en la fabricación del hormigón, revisando con detalle su contribución en las propiedades finales del producto, sin olvidar sus efectos en su comportamiento en estado fresco o cuando se encuentra en fase de endurecimiento. En el trabajo se incluyen e identifican las variables de mayor influencia y su relación con la propiedad que modificaron en el hormigón.

  13. Standard test methods for pitting and crevice corrosion resistance of stainless steels and related alloys by use of ferric Chloride solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 These test methods cover procedures for the determination of the resistance of stainless steels and related alloys to pitting and crevice corrosion (see Terminology G 15) when exposed to oxidizing chloride environments. Six procedures are described and identified as Methods A, B, C, D, E, and F. 1.1.1 Method A—Ferric chloride pitting test. 1.1.2 Method B—Ferric chloride crevice test. 1.1.3 Method C—Critical pitting temperature test for nickel-base and chromium-bearing alloys. 1.1.4 Method D—Critical crevice temperature test for nickel-base and chromium-bearing alloys. 1.1.5 Method E—Critical pitting temperature test for stainless steels. 1.1.6 Method F—Critical crevice temperature test for stainless steels. 1.2 Method A is designed to determine the relative pitting resistance of stainless steels and nickel-base, chromium-bearing alloys, whereas Method B can be used for determining both the pitting and crevice corrosion resistance of these alloys. Methods C, D, E and F allow for a rankin...

  14. A portable optical human sweat sensor

    Science.gov (United States)

    Al-omari, Mahmoud; Liu, Gengchen; Mueller, Anja; Mock, Adam; Ghosh, Ruby N.; Smith, Kyle; Kaya, Tolga

    2014-11-01

    We describe the use of HNQ (2-hydroxy-1,4-naphthoquinone or Lawsone) as a potential sweat sensor material to detect the hydration levels of human beings. We have conducted optical measurements using both artificial and human sweat to validate our approach. We have determined that the dominant compound that affects HNQ absorbance in artificial sweat is sodium. The presence of lactate decreases the reactivity of HNQ while urea promotes more interactions of sodium and potassium ions with HNQ. The interactions between the hydroxyl group of HNQ and the artificial sweat components (salts, lactic acid, and urea) were investigated comprehensively. We have also proposed and developed a portable diode laser absorption sensor system that converts the absorbance at a particular wavelength range (at 455 ± 5 nm, where HNQ has an absorbance peak) into light intensity measurements via a photocell. The absorbance intensity values obtained from our portable sensor system agrees within 10.4% with measurements from a laboratory based ultraviolet-visible spectrometer. Findings of this research will provide significant information for researchers who are focusing on real-time, in-situ hydration level detection.

  15. Sweat osmolarity shows intra-animal regional variation in the horse.

    Science.gov (United States)

    Potts, Samantha; Thatcher, Rhys; Jones, Arwel W; Warren, Lori K; Tenbroeck, Saundra H; Nottage, Florence; McEwan, Neil R

    2015-10-01

    Sweating is important in regulating body temperature but can be a source of loss of both fluids and electrolytes. Although the process has been studied in horses, the variation in sweat osmolarity across the body has not. This work describes an investigation to determine if there is regional variation in the osmolarity of sweat across different anatomical regions of the horse. Ten horses were used in the study and were animals either stabled for riding lessons or had livery on-site. Sweat samples were collected from five regions on each horse following exercise and the osmolarity measurements were made using an Osmomat 030 (Gonotec, Berlin, Germany). Values were analysed by paired t-tests and analysis of variance. Samples from the back and ears had statistically (P sweat collected from the horse's back. The current work demonstrates that these values are probably an underestimation of electrolyte loss, which may have implications for the composition and administration of rehydration compounds. © 2015 ESVD and ACVD.

  16. Variations in regional sweat composition in normal human males.

    Science.gov (United States)

    Patterson, M J; Galloway, S D; Nimmo, M A

    2000-11-01

    This project aimed to quantify the regional distribution of sweat composition over the skin surface and to determine whether sweat constituent concentrations collected from regional sites can estimate whole-body concentrations. Ten males cycled for 90 min in a 20 degrees C (50% relative humidity) environment at 45% peak aerobic power. Sweat was collected from eleven skin regions and the whole body, using a wash-down technique. Strong relationships were evident between the regional and whole-body sweat [Na+] and [Cl-], such that the thigh and calf exhibited greater correlation coefficients than area-weighted means derived from four and eight skin regions. Therefore, in this particular protocol the whole-body sweat [Na+] and [Cl-] could be predicted from regional sweat collections. Relationships between sweat constituents were evident for sweat [Na+] and pH, and sweat [K+] and [lactate] when data were pooled between skin regions and subjects. To our knowledge this is the first investigation to report a positive relationship between sweat [K+] and [lactate]. The exact mechanism responsible for the positive relationship between sweat [K+] and [lactate] is uncertain although it is speculated to occur at the secretory coil.

  17. Chloride test - blood

    Science.gov (United States)

    ... is called hypochloremia. It may be due to: Addison disease Bartter syndrome Burns Congestive heart failure Dehydration Excessive ... used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed ...

  18. Chloride - urine test

    Science.gov (United States)

    ... to: Body holding in too much salt (sodium retention) Cushing syndrome Decreased salt intake Fluid loss that ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...

  19. Skin pretreatment with microneedles prior to pilocarpine iontophoresis increases sweat production.

    Science.gov (United States)

    Wing, David; Prausnitz, Mark R; Buono, Michael J

    2013-11-01

    Collection of sweat via pilocarpine iontophoresis is commonly used to diagnose cystic fibrosis (CF), with thousands of tests performed each day. The main source of resistance to the passage of pilocarpine ions to the sweat glands is the electrical resistance of the stratum corneum. It was hypothesized that pretreating the skin with 0·5 mm-long microneedles would significantly decrease this resistance, thus increasing pilocarpine's permeation into the skin. Improved permeation should result in significantly reduced time to sweat initiation, time to collection of a clinically meaningful amount of sweat, and increased total amount of sweat produced in 15 min. Subjects (n = 12) had two 5 cm(2) areas on the forearm measured, marked and randomized to experimental (microneedles + iontophoresis) or control (iontophoresis alone). Microneedle pretreatment was conducted using a 35-needle microneedle stamp in a manner that 20 applications completely covered the 5 cm(2) treatment area. This was repeated five times for a total of 100 applications. Both experimental and control sites were placed under iontophoresis (1·5 mA) for 5 min. Microneedle pretreatment significantly decreased mean skin resistance (260 ± 27 kΩ versus 160 ± 19 kΩ, P = 0·006), while significantly increasing mean sweat rate (0·76 ± 0·35 versus 0·54 ± 0·19 μl cm(2) min(-1) , P = 0·007). No significant difference was found concerning pain (P = 0·059), number of active sweat glands (P = 0·627) or the osmolality of the collected sweat (P = 0·636). The results of this study suggest that microneedle pretreatment prior to pilocarpine iontophoresis significantly increases sweat production. Such results have the potential to improve the methodology currently used to diagnose cystic fibrosis and, more broadly, to administer drugs via the skin. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Skin Tattoos Alter Sweat Rate and Na+ Concentration.

    Science.gov (United States)

    Luetkemeier, Maurie Joe; Hanisko, Joseph Michael; Aho, Kyle Mathiew

    2017-07-01

    The popularity of tattoos has increased tremendously in the last 10 yr particularly among athletes and military personnel. The tattooing process involves permanently depositing ink under the skin at a similar depth as eccrine sweat glands (3-5 mm). The purpose of this study was to compare the sweat rate and sweat Na concentration of tattooed versus nontattooed skin. The participants were 10 healthy men (age = 21 ± 1 yr), all with a unilateral tattoo covering a circular area at least 5.2 cm. Sweat was stimulated by iontophoresis using agar gel disks impregnated with 0.5% pilocarpine nitrate. The nontattooed skin was located contralateral to the position of the tattooed skin. The disks used to collect sweat were composed of Tygon® tubing wound into a spiral so that the sweat was pulled into the tubing by capillary action. The sweat rate was determined by weighing the disk before and after sweat collection. The sweat Na concentration was determined by flame photometry. The mean sweat rate from tattooed skin was significantly less than nontattooed skin (0.18 ± 0.15 vs 0.35 ± 0.25 mg·cm·min; P = 0.001). All 10 participants generated less sweat from tattooed skin than nontattooed skin and the effect size was -0.79. The mean sweat Na concentration from tattooed skin was significantly higher than nontattooed skin (69.1 ± 28.9 vs 42.6 ± 15.2 mmol·L; P = 0.02). Nine of 10 participants had higher sweat Na concentration from tattooed skin than nontattooed skin, and the effect size was 1.01. Tattooed skin generated less sweat and a higher Na concentration than nontattooed skin when stimulated by pilocarpine iontophoresis.

  1. Standard test method for determining effects of chemical admixtures on corrosion of embedded steel reinforcement in concrete exposed to chloride environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for determining the effects of chemical admixtures on the corrosion of metals in concrete. This test method can be used to evaluate materials intended to inhibit chloride-induced corrosion of steel in concrete. It can also be used to evaluate the corrosivity of admixtures in a chloride environment. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Interindividual variability in sweat electrolyte concentration in marathoners.

    Science.gov (United States)

    Lara, Beatriz; Gallo-Salazar, César; Puente, Carlos; Areces, Francisco; Salinero, Juan José; Del Coso, Juan

    2016-01-01

    Sodium (Na(+)) intake during exercise aims to replace the Na(+) lost by sweat to avoid electrolyte imbalances, especially in endurance disciplines. However, Na(+) needs can be very different among individuals because of the great inter-individual variability in sweat electrolyte concentration. The aim of this investigation was to determine sweat electrolyte concentration in a large group of marathoners. A total of 157 experienced runners (141 men and 16 women) completed a marathon race (24.4 ± 3.6 °C and 27.7 ± 4.8 % of humidity). During the race, sweat samples were collected by using sweat patches placed on the runners' forearms. Sweat electrolyte concentration was measured by using photoelectric flame photometry. As a group, sweat Na(+) concentration was 42.9 ± 18.7 mmol·L(-1) (minimal-maximal value = 7.0-95.5 mmol·L(-1)), sweat Cl(-) concentration was 32.2 ± 15.6 mmol·L(-1) (7.3-90.6 mmol·L(-1)) and sweat K(+) concentration was 6.0 ± 0.9 mmol·L(-1) (3.1-8.0 mmol·L(-1)). Women presented lower sweat Na(+) (33.9 ± 12.1 vs 44.0 ± 19.1 mmol·L(-1); P = 0.04) and sweat Cl(-) concentrations (22.9 ± 10.5 vs 33.2 ± 15.8 mmol·L(-1); P = 0.01) than men. A 20 % of individuals presented a sweat Na(+) concentration higher than 60 mmol·L(-1) while this threshold was not surpassed by any female marathoner. Sweat electrolyte concentration did not correlate to sweat rate, age, body characteristics, experience or training. Although there was a significant correlation between sweat Na(+) concentration and running pace (r = 0.18; P = 0.03), this association was weak to interpret that sweat Na(+) concentration increased with running pace. The inter-individual variability in sweat electrolyte concentration was not explained by any individual characteristics except for individual running pace and sex. An important portion (20 %) of marathoners might need special sodium intake recommendations due to

  3. Tellurite glass as a waste form for a simulated mixed chloride waste stream: Candidate materials selection and initial testing

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Brian J.; Rieck, Bennett T.; McCloy, John S.; Crum, Jarrod V.; Sundaram, S. K.; Vienna, John D.

    2012-02-02

    Tellurite glasses have been researched widely for the last 60 years since they were first introduced by Stanworth. These glasses have been primarily used in research applications as glass host materials for lasers and as non-linear optical materials, though many other uses exist in the literature. Tellurite glasses have long since been used as hosts for various, and even sometimes mixed, halogens (i.e., multiple chlorides or even chlorides and iodides). Thus, it was reasonable to expect that these types of glasses could be used as a waste form to immobilize a combination of mixed chlorides present in the electrochemical separations process involved with fuel separations and processing from nuclear reactors. Many of the properties related to waste forms (e.g., chemical durability, maximum chloride loading) for these materials are unknown and thus, in this study, several different types of tellurite glasses were made and their properties studied to determine if such a candidate waste form could be fabricated with these glasses. One of the formulations studied was a lead tellurite glass, which had a low sodium release and is on-par with high-level waste silicate glass waste forms.

  4. Vitamin B12 deficiency causing night sweats.

    Science.gov (United States)

    Rehman, H U

    2014-11-01

    Vitamin B12 deficiency is common. It is known to cause a wide spectrum of neurological syndromes, including autonomic dysfunction. Three cases are discussed here in which drenching night sweats were thought to be caused by vitamin B12 deficiency. All three responded dramatically to vitamin B12 therapy. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Tactile cues significantly modulate the perception of sweat-induced skin wetness independently of the level of physical skin wetness.

    Science.gov (United States)

    Filingeri, Davide; Fournet, Damien; Hodder, Simon; Havenith, George

    2015-06-01

    Humans sense the wetness of a wet surface through the somatosensory integration of thermal and tactile inputs generated by the interaction between skin and moisture. However, little is known on how wetness is sensed when moisture is produced via sweating. We tested the hypothesis that, in the absence of skin cooling, intermittent tactile cues, as coded by low-threshold skin mechanoreceptors, modulate the perception of sweat-induced skin wetness, independently of the level of physical wetness. Ten males (22 yr old) performed an incremental exercise protocol during two trials designed to induce the same physical skin wetness but to induce lower (TIGHT-FIT) and higher (LOOSE-FIT) wetness perception. In the TIGHT-FIT, a tight-fitting clothing ensemble limited intermittent skin-sweat-clothing tactile interactions. In the LOOSE-FIT, a loose-fitting ensemble allowed free skin-sweat-clothing interactions. Heart rate, core and skin temperature, galvanic skin conductance (GSC), and physical (w(body)) and perceived skin wetness were recorded. Exercise-induced sweat production and physical wetness increased significantly [GSC: 3.1 μS, SD 0.3 to 18.8 μS, SD 1.3, P FIT and LOOSE-FIT (P > 0.05). However, the limited intermittent tactile inputs generated by the TIGHT-FIT ensemble reduced significantly whole-body and regional wetness perception (P < 0.01). This reduction was more pronounced when between 40 and 80% of the body was covered in sweat. We conclude that the central integration of intermittent mechanical interactions between skin, sweat, and clothing, as coded by low-threshold skin mechanoreceptors, significantly contributes to the ability to sense sweat-induced skin wetness. Copyright © 2015 the American Physiological Society.

  6. Tropical Malaysians and temperate Koreans exhibit significant differences in sweating sensitivity in response to iontophoretically administered acetylcholine

    Science.gov (United States)

    Lee, Jeong-Beom; Bae, Jun-Sang; Matsumoto, Takaaki; Yang, Hun-Mo; Min, Young-Ki

    2009-03-01

    Natives of the tropics are able to tolerate high ambient temperatures. This results from their long-term residence in hot and often humid tropical climates. This study was designed to compare the peripheral mechanisms of thermal sweating in tropical natives with that of their temperate counterparts. Fifty-five healthy male subjects including 20 native Koreans who live in the temperate Korean climate (Temperate-N) and 35 native tropical Malaysian men that have lived all of their lives in Malaysia (Tropical-N) were enrolled in this study after providing written informed consent to participate. Quantitative sudomotor axon reflex testing after iontophoresis (2 mA for 5 min) with 10% acetylcholine (ACh) was used to determine directly activated (DIR) and axon reflex-mediated (AXR) sweating during ACh iontophoresis. The sweat rate, activated sweat gland density, sweat gland output per single gland activated, and oral and skin temperature changes were measured. The sweat onset time of AXR (nicotinic-receptor-mediated) was 56 s shorter in the Temperate-N than in the Tropical-N subjects ( P stress.

  7. Pilocarpine iontophoresis test

    DEFF Research Database (Denmark)

    Hjortskov, N; Jepsen, Leif; Nielsen, B

    1995-01-01

    The pilocarpine iontophoresis test (P-test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P-test reflects whole-body and regional sweat secretion...... during exercise in the heat. Finally, we determined whether the P-test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone-deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion......, the patients exercised on a bicycle ergometer at a workload corresponding to 40% of their maximal aerobic power (VO2max). The 11 healthy subjects exercised at a workload of 150 W. All subjects exercised for 60 min in ambient air at 35 degrees C, with 50% relative humidity. The P-test showed a mean day...

  8. Pilocarpine iontophoresis test

    DEFF Research Database (Denmark)

    Hjortskov, N; Jepsen, Leif; Nielsen, B

    1995-01-01

    , the patients exercised on a bicycle ergometer at a workload corresponding to 40% of their maximal aerobic power (VO2max). The 11 healthy subjects exercised at a workload of 150 W. All subjects exercised for 60 min in ambient air at 35 degrees C, with 50% relative humidity. The P-test showed a mean day......The pilocarpine iontophoresis test (P-test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P-test reflects whole-body and regional sweat secretion...... during exercise in the heat. Finally, we determined whether the P-test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone-deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion...

  9. The significance of hypersensitivity to autologous sweat and serum in cholinergic urticaria: cholinergic urticaria may have different subtypes.

    Science.gov (United States)

    Kim, Jung Eun; Jung, Kwan Ho; Cho, Hyun Hee; Kang, Hoon; Park, Young Min; Park, Hyun Jeong; Lee, Jun Young

    2015-07-01

    The pathogenesis of cholinergic urticaria (ChU) has been unclear except for the involvement of acetylcholine. Attempts to classify ChU according to etiology have rarely been performed. To evaluate the significance of responsiveness to autologous sweat and serum in ChU in relation to their clinical characteristics. This study involved 18 patients diagnosed with ChU between January 2010 and April 2011 in the Catholic Medical Center-St. Paul's Hospital. History taking included symptom duration, association with atopy, decreased sweat secretions, seasonal variation, and response to treatment. Intradermal autologous serum skin test (ASST) and autologous sweat skin test (ASwST) and basophil histamine release test with sweat were done. Sweat hypersensitivity was proven by a positive ASwST and basophil histamine release test in only 37.5% of patients with ChU, and in none of the healthy controls. The weal size of ASwST correlated with percentage basophil histamine release. A positive response to autologous serum was displayed by 38.9% of patients, whereas 10% of healthy controls showed a positive ASST response. Intriguingly, patients with a positive ASwST had a negative ASST, and vice versa. Despite this, there was no difference in the clinical characteristics between positive ASST and positive ASwST groups. The frequency of hypersensitivity to autologous sweat and serum was significantly higher in patients with ChU, compared with healthy controls. This suggests that autoimmunity to an unknown serum factor as well as sweat hypersensitivity may be involved in the pathogenesis of ChU. © 2014 The International Society of Dermatology.

  10. Decreased sweating in seven patients with Laron syndrome

    DEFF Research Database (Denmark)

    Main, K M; Price, D A; Savage, M O

    1993-01-01

    Previous studies have shown that sweat secretion was reduced in patients with GH deficiency and increased during GH treatment, indicating an influence of GH on sweat gland function. Thus, patients with GH deficiency have impaired thermoregulation. We report on sweat secretion rates (SSRs) in seven......). These observations further supported the hypothesis that sweat gland function in humans is under the influence of the GH-insulin-like growth factor-I axis. It remains to be seen whether the decrease in SSR also leads to altered thermoregulation in patients with Laron syndrome....

  11. Measurements of clothing evaporative resistance using a sweating thermal manikin: an overview

    Science.gov (United States)

    WANG, Faming

    2017-01-01

    Evaporative resistance has been widely used to describe the evaporative heat transfer property of clothing. It is also a critical variable in heat stress models for predicting human physiological responses in various environmental conditions. At present, sweating thermal manikins provide a fast and cost-effective way to determine clothing evaporative resistance. Unfortunately, the measurement repeatability and reproducibility of evaporative resistance are rather low due to the complicated moisture transfer processes through clothing. This review article presents a systematical overview on major influential factors affecting the measurement precision of clothing evaporative resistance measurements. It also illustrates the state-of-the-art knowledge on the development of test protocol to measure clothing evaporative resistance by means of a sweating manikin. Some feasible and robust test procedures for measurement of clothing evaporative resistance using a sweating manikin are described. Recommendations on how to improve the measurement accuracy of clothing evaporative resistance are addressed and expected future trends on development of advanced sweating thermal manikins are finally presented. PMID:28566566

  12. [Amounts of sweat and salt loss due to sweating during a three-hour badminton practice in summer].

    Science.gov (United States)

    Hashimoto, Yoshiaki; Watanabe, Nobuko; Futamura, Azusa

    2007-11-01

    In 7 men and 5 women, we measured the amounts of sweat and fluid intake, and the ionic composition of sweat during a 3-hour badminton practice in summer. The amount of sweat was calculated as follows; body weight before practice (g)--body weight after practice (g)--urine volume (ml) +fluid intake (ml). We collected sweat by covering the non-dominant forearm with a plastic bag. The amounts of sweat and fluid intake during the 3-hour practice were 1809 +/- 715ml (mean +/- SD) and 658 +/- 344ml, respectively. Weight loss after the practice was 2.0 +/- 0.9% of their weight before the practice. The Na(+) and Cl(-) levels of the sweat about 30 min after the start of practice were 66 +/- 34 mEq/l and 54 +/- 32mEq/l, respectively. There was no significant difference between those ionic levels of the sweat about 30 min after the start of practice and those about 30 min before the end of practice. The sum of Na(+) and Cl(-) loss into sweat during a 3-hour practice session was supposed to be 6.9 +/- 5.3g, and to be above 10 g in 4 of 7 men, assuming that there were no regional differences in the ionic composition of sweat. The findings suggested that most of the participants should take more fluid and some of them might need salt intake during the practice.

  13. Effects of short-term exercise in the heat on thermoregulation, blood parameters, sweat secretion and sweat composition of tropic-dwelling subjects.

    Science.gov (United States)

    Saat, Mohamed; Sirisinghe, Roland Gamini; Singh, Rabindarjeet; Tochihara, Yutaka

    2005-09-01

    This study investigates the effects of a short-term aerobic training program in a hot environment on thermoregulation, blood parameters, sweat secretion and composition in tropic-dwellers who have been exposed to passive heat. Sixteen healthy Malaysian-Malay male volunteers underwent heat acclimation (HA) by exercising on a bicycle ergometer at 60% of VO2max for 60 min each day in a hot environment (Ta: 31.1+/-0.1 degrees C, rh: 70.0+/-4.4%) for 14 days. All parameters mentioned above were recorded on Day 1 and at the end of HA (Day 16). On these two days, subjects rested for 10 min, then cycled at 60% of VO2max for 60 min and rested again for 20 min (recovery) in an improvised heat chamber. Rectal temperature (Tre), mean skin temperature (Tsk) heart rate (HR), ratings of perceived exertion (RPE), thermal sensation (TS), local sweat rate and percent dehydration were recorded during the test. Sweat concentration was analysed for sodium [Na+]sweat and potassium. Blood samples were analysed for biochemical changes, electrolytes and hematologic indices. Urine samples were collected before and after each test and analysed for electrolytes.After the period of acclimation the percent dehydration during exercise significantly increased from 1.77+/-0.09% (Day 1) to 2.14+/-0.07% (Day 16). Resting levels of hemoglobin, hematocrit and red blood cells decreased significantly while [Na+]sweat increased significantly. For Tre and Tsk there were no differences at rest. Tre, HR, RPE, TS, plasma lactate concentration, hemoglobin and hematocrit at the 40th min of exercise were significantly lower after the period of acclimation but mean corpuscular hemoglobin and serum osmolality were significantly higher while no difference was seen in [Na+]sweat and Tsk. It can be concluded that tropic-dwelling subjects, although exposed to prolonged passive heat exposure, were not fully heat acclimatized. To achieve further HA, they should gradually expose themselves to exercise-heat stress in a

  14. Effect of plasma prolactin on sweat rate and sweat composition during exercise in men.

    Science.gov (United States)

    Boisvert, P; Brisson, G R; Péronnet, F

    1993-05-01

    We investigated the role of the exercise-induced elevation of plasma prolactin (PRL) concentration on sweat rate and composition during prolonged exercise in men. Two groups of healthy young males (20-26 yr old) showing a high (high responders; n = 8) or a low (low responders; n = 7) response of plasma PRL concentration to exercise were studied during a 60-min period of exercise on a cycle ergometer (65% maximum O2 consumption) in warm conditions (26.2 +/- 0.1 degrees C; 57 +/- 1% relative humidity), 1 h after receiving 1.25 mg bromocriptine (BRC) per os or a placebo. In high responders, administration of BRC totally abolished the threefold increase in plasma PRL observed in response to exercise with placebo [placebo, 10 +/- 2 (rest) and 30 +/- 2 micrograms/l (exercise); BRC, 9 +/- 1 (rest) and 8 +/- 1 microgram/l (exercise)]. The latter was associated with a significant decrease in sweat rate (2.7 +/- 0.5 to 1.9 +/- 0.3 microliter.cm-2.min-1) and a significant increase in sweat Na+ concentration (57 +/- 7 to 68 +/- 5 mmol/l). BRC also reduced the small response in plasma PRL concentration observed in low responders [placebo, 10 +/- 1 (rest) and 15 +/- 1 microgram/l (exercise); BRC, 9 +/- 1 (rest) and 7 +/- 1 microgram/l (exercise)], but this was not associated with any change in sweat rate (2.2 +/- 0.2 to 1.9 +/- 0.3 microliter.cm-2.min-1) or in sweat Na+ concentration (63 +/- 10 to 64 +/- 9 mmol/l).(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Characteristics of sweating responses and peripheral sweat gland function during passive heating in sprinters.

    Science.gov (United States)

    Amano, Tatsuro; Koga, Shunsaku; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Kondo, Narihiko

    2013-08-01

    The purpose of this study was to compare sweating function in sprinters who have trained for several years with untrained subjects and trained endurance runners. Two separate experiments were conducted. Nine sprinters, eight untrained men, and nine distance runners (VO2 max 50.9 ± 1.4, 38.2 ± 1.8, and 59.1 ± 1.2 mL/kg/min, respectively; P sprinters, 11 untrained men and nine distance runners (similar VO2 max levels compared with Experiment 1 in each group) had their sweat gland capacity assessed based on acetylcholine-induced sweating rate (SR) (Experiment 2). The slope of the mean non-glabrous SR plotted against change in mean body temperature during passive heating did not differ significantly between sprinters and untrained men (1.21 ± 0.10 and 0.97 ± 0.12 mg cm(-2)/min/°C, respectively); in contrast, compared with untrained men, distance runners exhibited a significantly greater slope (1.42 ± 0.11 mg cm(-2)/min/°C, P sprinters and untrained men, whereas distance runners showed a significantly higher induced SR compared with untrained men. The sweating function was not improved in sprinters who have trained 2-3 h/day, 5 days/week, for at least 3 years compared with untrained men, although the VO2 max was markedly greater in sprinters. Thus, there is a case that daily training was not sufficient to improve sweating function in sprinters relative to those in distance runners.

  16. Biomonitoring and Elimination of Perfluorinated Compounds and Polychlorinated Biphenyls through Perspiration: Blood, Urine, and Sweat Study

    Science.gov (United States)

    Genuis, Stephen J.; Beesoon, Sanjay; Birkholz, Detlef

    2013-01-01

    Perfluorinated compounds (PFCs) are man-made organofluorine chemicals manufactured and marketed for their stain-resistant properties. Polychlorinated biphenyls (PCBs) are anthropogenic organochlorine compounds previously used in various industrial and chemical applications prior to being banned in the Western world in the 1970s. Both PFCs and PCBs are persistent contaminants within the human organism and both have been linked to adverse health sequelae. Data is lacking on effective means to facilitate clearance of PFCs and PCBs from the body. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for PFCs and PCBs using high performance liquid chromatography tandem mass spectrometry. Results. Some individual PCB congeners, but not all, were released into sweat at varying concentrations. None of the PFCs found in serum testing appeared to be excreted efficiently into perspiration. Conclusions. Induced perspiration may have some role in facilitating elimination of selected PCBs. Sweat analysis may be helpful in establishing the existence of some accrued PCBs in the human body. Sweating does not appear to facilitate clearance of accrued PFHxS (perfluorohexane sulfonate), PFOS (perfluorooctane sulfonate), or PFOA (perfluorooctanoic acid), the most common PFCs found in the human body. PMID:24083032

  17. Genotoxicological assessment of two reactive dyes extracted from cotton fibres using artificial sweat.

    Science.gov (United States)

    Leme, Daniela Morais; de Oliveira, Gisele Augusto Rodrigues; Meireles, Gabriela; dos Santos, Tuane Cristina; Zanoni, Maria Valnice Boldrin; de Oliveira, Danielle Palma

    2014-02-01

    Human eyes have a remarkable ability to recognize hundreds of colour shades, which has stimulated the use of colorants, especially for clothing, but toxicological studies have shown that some textile dyes can be hazardous to human health. Under conditions of intense perspiration, dyes can migrate from coloured clothes and penetrate into human skin. Garments made from cotton fabrics are the most common clothing in tropical countries, due to their high temperatures. Aiming to identify safe textile dyes for dyeing cotton fabrics, the genotoxicity [in vitro Comet assay with normal human dermal fibroblasts (NHDF), Tail Intensity] and mutagenicity [Salmonella/microsome preincubation assay (30min), tester strains TA98, TA100, YG1041 and YG1042] of Reactive Blue 2 (RB2, CAS No. 12236-82-7, C.I. 61211) and Reactive Green 19 (RG19, CAS No. 61931-49-5, C.I. 205075) were evaluated both in the formulated form and as extracted from cotton fibres using different artificial sweats. Both the dyes could migrate from cotton fibres to sweat solutions, the sweat composition and pH being important factors during this extraction. However, the dye sweat solutions showed no genotoxic/mutagenic effects, whereas a weak mutagenic potential was detected by the Ames test for both dyes in their formulated form. These findings emphasize the relevance of textile dyes assessment under conditions that more closely resemble human exposure, in order to recognize any hazard. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. A little CFTR goes a long way: CFTR-dependent sweat secretion from G551D and R117H-5T cystic fibrosis subjects taking ivacaftor.

    Science.gov (United States)

    Char, Jessica E; Wolfe, Marlene H; Cho, Hyung-Ju; Park, Il-Ho; Jeong, Jin Hyeok; Frisbee, Eric; Dunn, Colleen; Davies, Zoe; Milla, Carlos; Moss, Richard B; Thomas, Ewart A C; Wine, Jeffrey J

    2014-01-01

    To determine if oral dosing with the CFTR-potentiator ivacaftor (VX-770, Kalydeco) improves CFTR-dependent sweating in CF subjects carrying G551D or R117H-5T mutations, we optically measured sweat secretion from 32-143 individually identified glands in each of 8 CF subjects; 6 F508del/G551D, one G551D/R117H-5T, and one I507del/R117H-5T. Two subjects were tested only (-) ivacaftor, 3 only (+) ivacaftor and 3 (+/-) ivacaftor (1-5 tests per condition). The total number of gland measurements was 852 (-) ivacaftor and 906 (+) ivacaftor. A healthy control was tested 4 times (51 glands). For each gland we measured both CFTR-independent (M-sweat) and CFTR-dependent (C-sweat); C-sweat was stimulated with a β-adrenergic cocktail that elevated [cAMP]i while blocking muscarinic receptors. Absent ivacaftor, almost all CF glands produced M-sweat on all tests, but only 1/593 glands produced C-sweat (10 tests, 5 subjects). By contrast, 6/6 subjects (113/342 glands) produced C-sweat in the (+) ivacaftor condition, but with large inter-subject differences; 3-74% of glands responded with C/M sweat ratios 0.04%-2.57% of the average WT ratio of 0.265. Sweat volume losses cause proportionally larger underestimates of CFTR function at lower sweat rates. The losses were reduced by measuring C/M ratios in 12 glands from each subject that had the highest M-sweat rates. Remaining losses were estimated from single channel data and used to correct the C/M ratios, giving estimates of CFTR function (+) ivacaftor  = 1.6%-7.7% of the WT average. These estimates are in accord with single channel data and transcript analysis, and suggest that significant clinical benefit can be produced by low levels of CFTR function.

  19. A little CFTR goes a long way: CFTR-dependent sweat secretion from G551D and R117H-5T cystic fibrosis subjects taking ivacaftor.

    Directory of Open Access Journals (Sweden)

    Jessica E Char

    Full Text Available To determine if oral dosing with the CFTR-potentiator ivacaftor (VX-770, Kalydeco improves CFTR-dependent sweating in CF subjects carrying G551D or R117H-5T mutations, we optically measured sweat secretion from 32-143 individually identified glands in each of 8 CF subjects; 6 F508del/G551D, one G551D/R117H-5T, and one I507del/R117H-5T. Two subjects were tested only (- ivacaftor, 3 only (+ ivacaftor and 3 (+/- ivacaftor (1-5 tests per condition. The total number of gland measurements was 852 (- ivacaftor and 906 (+ ivacaftor. A healthy control was tested 4 times (51 glands. For each gland we measured both CFTR-independent (M-sweat and CFTR-dependent (C-sweat; C-sweat was stimulated with a β-adrenergic cocktail that elevated [cAMP]i while blocking muscarinic receptors. Absent ivacaftor, almost all CF glands produced M-sweat on all tests, but only 1/593 glands produced C-sweat (10 tests, 5 subjects. By contrast, 6/6 subjects (113/342 glands produced C-sweat in the (+ ivacaftor condition, but with large inter-subject differences; 3-74% of glands responded with C/M sweat ratios 0.04%-2.57% of the average WT ratio of 0.265. Sweat volume losses cause proportionally larger underestimates of CFTR function at lower sweat rates. The losses were reduced by measuring C/M ratios in 12 glands from each subject that had the highest M-sweat rates. Remaining losses were estimated from single channel data and used to correct the C/M ratios, giving estimates of CFTR function (+ ivacaftor  = 1.6%-7.7% of the WT average. These estimates are in accord with single channel data and transcript analysis, and suggest that significant clinical benefit can be produced by low levels of CFTR function.

  20. [Estimation of the sweat composition of fatty acids].

    Science.gov (United States)

    Solovskaia, S S; Varus, V I; Briuzgina, T S; Belov, A A; Ivanov, D A

    2007-05-01

    Changes in the fatty acid composition of sweat lipid were studied in persons whose activity was associated with military service. There were significant changes in essential fatty acids of sweat lipids, which made it possible to use this noninvasive biological object as a criterion for rating dysadaptive processes in armed forces personnel.

  1. Metal ion release and surface composition of the Cu 18Ni 20Zn nickel silver during 30 days immersion in artificial sweat

    Science.gov (United States)

    Milošev, Ingrid; Kosec, Tadeja

    2007-11-01

    In order to study nickel ion release associated with nickel allergy, Cu-18Ni-20Zn nickel-silver alloy was immersed in artificial sweat and Ringer physiological solution for 30 days. Dissolution of metal ions was measured as a function of time, and the characteristics of the solid surface layer formed after 30 days were studied by SEM/EDS and XPS. The dissolution of nickel prevails over dissolution of copper and zinc. Nickel release in artificial sweat is approximately 10 times higher than in Ringer physiological solution and in both solutions the nickel release exceeds 0.5 μg cm -2 week -1, the threshold above which the allergy is triggered. Evidence of selective nickel dissolution is reported. The composition of the surface layer formed in artificial sweat and in Ringer physiological solution differs in the content of nickel and chlorine. In artificial sweat, the major constituents of the surface layer are dominantly oxides, Cu 2O and ZnO, with traces of chlorine. In Ringer physiological solution, the composition of the surface layer changes to a mixture of oxides, chlorides and/or oxychlorides. Two components peaks were detected in the Cl 2p 3/2 peak; however, it was not possible to distinguish the exact nature of the chloride compound formed. The mechanism of nickel release is discussed as a function of the composition of the solution.

  2. Prediction of Chloride Penetration into Hardening Concrete

    Directory of Open Access Journals (Sweden)

    Wei-Jie Fan

    2015-01-01

    Full Text Available In marine and coastal environments, penetration of chloride ions is one of the main mechanisms causing concrete reinforcement corrosion. Currently, most of experimental investigations about submerged penetration of chloride ions are started after the four-week standard curing of concrete. The further hydration of cement and reduction of chloride diffusivity during submerged penetration period are ignored. To overcome this weak point, this paper presents a numerical procedure to analyze simultaneously cement hydration reaction and chloride ion penetration process. First, using a cement hydration model, degree of hydration and phase volume fractions of hardening concrete are determined. Second, the dependences of chloride diffusivity and chloride binding capacity on age of concrete are clarified. Third, chloride profiles in hardening concrete are calculated. The proposed numerical procedure is verified by using chloride submerged penetration test results of concrete with different mixing proportions.

  3. Tribenzylammonium chloride

    Directory of Open Access Journals (Sweden)

    Waly Diallo

    2014-05-01

    Full Text Available Single crystals of the title salt, C21H21NH+·Cl−, were isolated as a side product from the reaction involving [(C6H5CH23NH]2[HPO4] and Sn(CH33Cl in ethanol. Both the cation and the anion are situated on a threefold rotation axis. The central N atom in the cation has a slightly distorted tetrahedral environment, with angles ranging from 107.7 to 111.16 (10°. In the crystal, the tribenzylammonium cations and chloride anions are linked through N—H...Cl and C—H...Cl hydrogen bonds, leading to the formation of infinite chains along [001]. The crystal studied was a merohedral twin.

  4. Correlation between Wavelength Dispersive X-ray Fluorescence (WDXRF) analysis of hardened concrete for chlorides vs. Atomic Absorption (AA) analysis in accordance with AASHTO T- 260; sampling and testing for chloride ion in concrete and concrete raw mater

    Science.gov (United States)

    2014-04-01

    A correlation between Wavelength Dispersive X-ray Fluorescence(WDXRF) analysis of Hardened : Concrete for Chlorides and Atomic Absorption (AA) analysis (current method AASHTO T-260, procedure B) has been : found and a new method of analysis has been ...

  5. Improved Devices for Collecting Sweat for Chemical Analysis

    Science.gov (United States)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2011-01-01

    Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available

  6. Sauna, sweat and science - quantifying the proportion of condensation water versus sweat using a stable water isotope ((2)H/(1)H and (18)O/(16)O) tracer experiment.

    Science.gov (United States)

    Zech, Michael; Bösel, Stefanie; Tuthorn, Mario; Benesch, Marianne; Dubbert, Maren; Cuntz, Matthias; Glaser, Bruno

    2015-01-01

    Most visitors of a sauna appreciate the heat pulse that is perceived when water is poured on the stones of a sauna stove. However, probably only few bathers are aware that this pleasant heat pulse is caused by latent heat being released onto our skin due to condensation of water vapour. In order to quantify the proportion of condensation water versus sweat to dripping water of test persons we conducted sauna experiments using isotopically labelled (δ(18)O and δ(2)H) thrown water as tracer. This allows differentiating between 'pure sweat' and 'condensation water'. Two ways of isotope mass balance calculations were applied and yielded similar results for both water isotopes. Accordingly, condensation contributed considerably to dripping water with mean proportions of 52 ± 12 and 54 ± 7% in a sauna experiment in winter semester 2011/12 and 30 ± 13 and 33 ± 6% in a sauna experiment in winter semester 2012/13, respectively, depending on the way of calculating the isotope mass balance. It can be concluded from the results of our dual isotope labelling sauna experiment that it is not all about sweat in the sauna.

  7. Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics

    Science.gov (United States)

    Munje, Rujuta D.; Muthukumar, Sriram; Panneer Selvam, Anjan; Prasad, Shalini

    2015-09-01

    An ultra-sensitive and highly specific electrical double layer (EDL) modulated biosensor, using nanoporous flexible substrates for wearable diagnostics is demonstrated with the detection of the stress biomarker cortisol in synthetic and human sweat. Zinc oxide thin film was used as active region in contact with the liquid i.e. synthetic and human sweat containing the biomolecules. Cortisol detection in sweat was accomplished by measuring and quantifying impedance changes due to modulation of the double layer capacitance within the electrical double layer through the application of a low orthogonally directed alternating current (AC) electric field. The EDL formed at the liquid-semiconductor interface was amplified in the presence of the nanoporous flexible substrate allowing for measuring the changes in the alternating current impedance signal due to the antibody-hormone interactions at diagnostically relevant concentrations. High sensitivity of detection of 1 pg/mL or 2.75 pmol cortisol in synthetic sweat and 1 ng/mL in human sweat is demonstrated with these novel biosensors. Specificity in synthetic sweat was demonstrated using a cytokine IL-1β. Cortisol detection in human sweat was demonstrated over a concentration range from 10-200 ng/mL.

  8. A new method of artificial latent fingerprint creation using artificial sweat and inkjet printer.

    Science.gov (United States)

    Hong, Sungwook; Hong, Ingi; Han, Aleum; Seo, Jin Yi; Namgung, Juyoung

    2015-12-01

    In order to study fingerprinting in the field of forensic science, it is very important to have two or more latent fingerprints with identical chemical composition and intensity. However, it is impossible to obtain identical fingerprints, in reality, because fingerprinting comes out slightly differently every time. A previous research study had proposed an artificial fingerprint creation method in which inkjet ink was replaced with amino acids and sodium chloride solution: the components of human sweat. But, this method had some drawbacks: divalent cations were not added while formulating the artificial sweat solution, and diluted solutions were used for creating weakly deposited latent fingerprint. In this study, a method was developed for overcoming the drawbacks of the methods used in the previous study. Several divalent cations were added in this study because the amino acid-ninhydrin (or some of its analogues) complex is known to react with divalent cations to produce a photoluminescent product; and, similarly, the amino acid-1,2-indanedione complex is known to be catalyzed by a small amount of zinc ions to produce a highly photoluminescent product. Also, in this study, a new technique was developed which enables to adjust the intensity when printing the latent fingerprint patterns. In this method, image processing software is used to control the intensity of the master fingerprint patterns, which adjusts the printing intensity of the latent fingerprints. This new method opened the way to produce a more realistic artificial fingerprint in various strengths with one artificial sweat working solution. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. The effect of heat acclimation on sweat microminerals: Artifact of surface contamination

    Science.gov (United States)

    Heat acclimation (HA) reportedly conveys conservation in sweat micromineral concentrations when sampled from arm sweat, but time course is unknown. The observation that comprehensive cleaning of the skin surface negates sweat micromineral reductions during prolonged sweating raises the question of w...

  10. Genetics Home Reference: cold-induced sweating syndrome

    Science.gov (United States)

    ... my area? Other Names for This Condition CISS CNTF receptor-related disorders Crisponi syndrome Sohar-Crisponi syndrome ... of cardiotrophin-like cytokine, a second ligand for ciliary neurotrophic factor receptor, leads to cold-induced sweating syndrome in ...

  11. Sweat Gland Progenitors in Development, Homeostasis, and Wound Repair

    Science.gov (United States)

    Lu, Catherine; Fuchs, Elaine

    2014-01-01

    The human body is covered with several million sweat glands. These tiny coiled tubular skin appendages produce the sweat that is our primary source of cooling and hydration of the skin. Numerous studies have been published on their morphology and physiology. Until recently, however, little was known about how glandular skin maintains homeostasis and repairs itself after tissue injury. Here, we provide a brief overview of sweat gland biology, including newly identified reservoirs of stem cells in glandular skin and their activation in response to different types of injuries. Finally, we discuss how the genetics and biology of glandular skin has advanced our knowledge of human disorders associated with altered sweat gland activity. PMID:24492848

  12. \\'Sweat Equity\\': Women\\'s Participation in Subsidised Housing in ...

    African Journals Online (AJOL)

    Abstract. The notion of \\"sweat equity\\" has been promoted as an integral part of subsidised housing in South African Housing policy. It\\'s tougher for females, though. Africa Insight Vol.34(2/3) 2004: 58-64 ...

  13. Cancer treatment: dealing with hot flashes and night sweats

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000826.htm Cancer treatment: dealing with hot flashes and night sweats To use ... stress reduction. Learning how to decrease stress and anxiety may help relieve hot flashes in some people. ...

  14. A Spectrophotometric Assay for Robust Viability Testing of Seed Batches Using 2,3,5-Triphenyl Tetrazolium Chloride: Using Hordeum vulgare L. as a Model

    Directory of Open Access Journals (Sweden)

    Laura Lopez Del Egido

    2017-05-01

    Full Text Available A comparative analysis was carried out of published methods to assess seed viability using 2,3,5-triphenyltetrazolium chloride (TTC based assays of seed batches. The tests were carried out on seeds of barley (Hordeum vulgare cv. Optic as a model. We established that 10% [w/v] trichloroacetic acid (TCA/methanol is superior to the acetone and methanol-only based methods: allowing the highest recovery of formazan and the lowest background optical density (OD readings, across seed lots comprising different ratios of viable and dead seeds. The method allowed a linear-model to accurately capture the statistically significant relationship between the quantity of formazan that could be extracted using the method we developed and the seed temperature-response, and seed viability as a function of artificially aged seed lots. Other quality control steps are defined to help ensure the assay is robust and these are reported in a Standard Operating Procedure.

  15. Observation of the sweating in lipstick by scanning electron microscopy.

    Science.gov (United States)

    Seo, S Y; Lee, I S; Shin, H Y; Choi, K Y; Kang, S H; Ahn, H J

    1999-06-01

    The relationship between the wax matrix in lipstick and sweating has been investigated by observing the change of size and shape of the wax matrix due to sweating by Scanning Electron Microscopy (SEM). For observation by SEM, a lipstick sample was frozen in liquid nitrogen. The oil in the lipstick was then extracted in cold isopropanol (-70 degrees C) for 1-3 days. After the isopropanol was evaporated, the sample was sputtered with gold and examined by SEM. The change of wax matrix underneath the surface from fine, uniform structure to coarse, nonuniform structure resulted from the caking of surrounding wax matrix. The oil underneath the surface migrated to the surface of lipstick with sweating; consequently the wax matrix in that region was rearranged into the coarse matrix. In case of flamed lipstick, sweating was delayed and the wax matrix was much coarser than that of the unflamed one. The larger wax matrix at the surface region was good for including oil. The effect of molding temperature on sweating was also studied. As the molding temperature rose, sweating was greatly reduced and the size of the wax matrix increased. It was found that sweating was influenced by the compatibility of wax and oil. A formula consisting of wax and oil that have good compatibility has a tendency to reduce sweating and increase the size of the wax matrix. When pigments were added to wax and oil, the size of the wax matrix was changed, but in all cases sweating was increased due to the weakening of the binding force between wax and oil. On observing the thick membrane of wax at the surface of lipstick a month after molding it was also found that sweating was influenced by ageing. In conclusion, the structure of the wax matrix at the surface region of lipstick was changed with the process of flaming, molding temperature, compatibility of wax and oil, addition of pigment, and ageing. In most cases, as the size of the wax matrix was increased, sweating was reduced and delayed.

  16. Study on moisture absorption and sweat discharge of honeycomb polyester fiber

    Science.gov (United States)

    Feng, Aifen; Zhang, Yongjiu

    2015-07-01

    The moisture absorption and liberation properties of honeycomb polyester fiber were studied in order to understand its moisture absorption and sweat discharge. Through testing moisture absorption and liberation regains of honeycomb polyester fiber and normal polyester fiber in standard atmospheric conditions, their moisture absorption and liberation curves were depicted, and the regression equations of moisture regains to time during their reaching the balance of moisture absorption and moisture liberation were obtained according to the curves. Their moisture absorption and liberation rate curves were analyzed and the regression equations of the rates to time were obtained. The results shows that the moisture regain of honeycomb polyester fiber is much bigger than the normal polyester fiber's, and the initial moisture absorption and moisture liberation rates of the former are much higher than the latter's, so that the moisture absorbance and sweat discharge of honeycomb polyester fiber are excellent.

  17. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research.

    Science.gov (United States)

    Agrawal, Karan; Hassoun, Lauren A; Foolad, Negar; Pedersen, Theresa L; Sivamani, Raja K; Newman, John W

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30-C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs.

  18. Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring.

    Science.gov (United States)

    Sim, Jai Kyoung; Yoon, Sunghyun; Cho, Young-Ho

    2018-01-19

    We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m 2 h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m 2 h in thermal statuses including 'comfortable', 'slightly warm', 'warm', and 'hot'. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.

  19. Trapped sweat in basketball uniforms and the effect on sweat loss estimates.

    Science.gov (United States)

    Baker, Lindsay B; Reimel, Adam J; Sopeña, Bridget C; Barnes, Kelly A; Nuccio, Ryan P; De Chavez, Peter John D; Stofan, John R; Carter, James M

    2017-09-01

    The aims of this study were to determine: (1) trapped sweat (TS) in basketball uniforms and the effect on sweat loss (SL) estimates during a laboratory-based basketball simulation protocol; (2) the impact of exercise intensity, body mass, age, and SL on TS; and (3) TS during on-court training to assess the ecological validity of the laboratory-based results. Twenty-four recreational/competitive male basketball players (23 ± 10 years, 77.0 ± 16.7 kg) completed three randomized laboratory-based trials (Low, Moderate, and High intensity) consisting of 150-min intermittent exercise. Eighteen elite male players (23 ± 4 years, 92.0 ± 20.6 kg) were observed during coach-led, on-court training. Nude and clothed body mass were measured pre and postexercise to determine TS. Data are mean ± SD. There was a significant effect of intensity on SL and TS ( P  < 0.001, Lowsweat and TS was 0.11 ± 0.15 kg (8.0 ± 5.1% SL). During Moderate, subjects lost 1.60 ± 0.56 kg sweat and TS was 0.21 ± 0.21 kg (11.6 ± 6.3% SL). During High, subjects lost 2.12 ± 0.66 kg sweat and TS was 0.38 ± 0.28 kg (16.0 ± 7.4% SL). Multiple regression and partial correlation analysis suggested TS was significantly related to SL ( P  < 0.0001; partial r  = 0.81-0.89), whereas the contributions of body mass ( P  = 0.22-0.92) and age ( P  = 0.29-0.44) were not significant. TS during on-court training was 0.35 ± 0.36 kg, which was associated with a 14.1 ± 11.5% underestimation in SL, and was not statistically different than laboratory-based results ( P  = 0.59). Clothed body mass measurements should be used with caution, as TS is highly variable and can cause a significant underestimation in SL in athletes with high sweating rates. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological

  20. Matrigel basement membrane matrix induces eccrine sweat gland cells to reconstitute sweat gland-like structures in nude mice.

    Science.gov (United States)

    Li, Haihong; Chen, Lu; Zeng, Shaopeng; Li, Xuexue; Zhang, Xiang; Lin, Changmin; Zhang, Mingjun; Xie, Sitian; He, Yunpu; Shu, Shenyou; Yang, Lvjun; Tang, Shijie; Fu, Xiaobing

    2015-03-01

    Severe burn results in irreversible damage to eccrine sweat glands, for which no effective treatment is available. Interaction between the extracellular matrix and epithelial cells is critical for proper three-dimensional organization and function of the epithelium. Matrigel-embedded eccrine sweat gland cells were subcutaneously implanted into the inguinal regions of nude mice. Two weeks later, the Matrigel plugs were removed and evaluated for series of detection items. Sweat gland cells developed into sweat gland-like structures in the Matrigel plugs based on: (1) de novo formation of tubular-like structures with one or more hollow lumens, (2) expression of epithelial and sweat gland markers (pancytokeratin, CK5/7/14/19, α-SMA and CEA), (3) basement membrane formation, (4) myoepithelial cells presenting in and encompassing the tubular-like structures, (5) cellular polarization, evident by the expression of tight junction proteins (claudin-1 and ZO-2), anchoring junctions (desmoglein-1 and -2 and E-cadherin) and CEA in the luminal membrane, (6) expression of proteins related to sweat secretion and absorption (Na(+)-K(+)-ATPase α/β, Na(+)-K(+)-2Cl-cotranspoter 1, Na(+)/H(+) exchanger 1, aquaporin-5, epithelial sodium channel, cystic fibrosis transmembrane conductance regulator, potassium channel and vacuolar-type H+-ATPase), and (7) about 20% of the tubular-like structures are de novo coils and 80% are de novo ducts. This study provides not only an excellent model to study eccrine sweat gland development, cytodifferentiation and reconstitution, but also an in vivo model for regeneration of eccrine sweat glands. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. The effect of environmental conditions on sodium chloride damage: A step in the development of an effective weathering test

    NARCIS (Netherlands)

    Lubelli, B.; Hees, R.P.J. van; Groot, C.J.W.P.

    2006-01-01

    Laboratory weathering tests are important in the field of restoration as they provide a means of estimating, in a relatively short time, the longer-term performance of conservation materials when applied in practice. Accelerated tests to simulate the damage caused to porous materials by soluble

  2. Sweat Farm Road Fire in Georgia

    Science.gov (United States)

    2007-01-01

    Dense plumes of blue-white smoke billowed from the Sweat Farm Road Fire in southern Georgia on April 19, 2007, when the Landsat 5 satellite captured this detailed image. The fire started on April 16, when a tree fell on a power line and, fanned by strong winds, quickly exploded into a major fire. By April 19, the fire had forced officials to close several roads, including U.S. Highway 1, and to evacuate hundreds of people from the perimeter of the city of Waycross, the silver cluster along the top edge of the image. The nearness of the fire is evident in the dark brown, charred land just south of the city. The active fire front is along the south edge of the burned area, where the flames are eating into the dark green hardwood forests, pine plantations, and shrubs in Okefenokee Swamp. Because of the difficult terrain, the fire and the adjoining Big Turnaround Complex fire are expected to burn until significant rain falls, said the morning report issued by the Southern Area Coordination Center on May 4. 'In the long term, the burning of the swamp will ultimately benefit the swamp wilderness habitat, which is a fire-dependent ecosystem,' said a press release issued from the Okefenokee National Wildlife Refuge on May 4. Such ecosystems require fire to remain healthy. In the case of southern pine forests, many pine species need fire to remove litter from the ground and release soil nutrients so that new seedlings can grow.

  3. Claudin-3 loss causes leakage of sweat from the sweat gland to contribute to the pathogenesis of atopic dermatitis.

    Science.gov (United States)

    Yamaga, Kosuke; Murota, Hiroyuki; Tamura, Atsushi; Miyata, Hirofumi; Ohmi, Masato; Kikuta, Junichi; Ishii, Masaru; Tsukita, Sachiko; Katayama, Ichiro

    2017-12-22

    The transfer of sweat to the skin surface without leakage is important for the homeostatic regulation of skin and is impaired in atopic dermatitis (AD). Although the precise composition of the leakage barrier remains obscure, there is a large contribution from claudins, the major components of tight junctions. In humans, claudin-1, -3, and -15 are expressed on sweat ducts, and claudin-3 and -10 are expressed on secretory coils. Although only two claudins are expressed in murine sweat glands, we found that the expression of claudin-3 is conserved. AD lesional skin had decreased claudin-3 expression in sweat glands, which was accompanied by sweat leakage. This critical role in water barrier function was confirmed in Cldn3 -/- and Cldn3 +/- mice and those with experimentally decreased claudin-3. Our results reveal the crucial role of claudin-3 in preventing sweat gland leakage and suggest that the pathogenesis of dermatoses accompanied by hypohidrosis involves abnormally decreased claudin-3. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress.

    Science.gov (United States)

    Schlader, Zachary J; Gagnon, Daniel; Lucas, Rebekah A I; Pearson, James; Crandall, Craig G

    2015-02-15

    This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm(-2)·min(-1)) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm(-2)·min(-1), P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm(-2)·min(-1); P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress. Copyright © 2015 the American Physiological Society.

  5. Elemental composition of muscle at rest and potassium levels in muscle, plasma and sweat of horses exercising at 20 degrees C and 35 degrees C.

    Science.gov (United States)

    Gottlieb-Vedi, M; Dahlborn, K; Jansson, A; Wroblewski, R

    1996-07-01

    In this study, 4 Standardbred geldings were exercised at 20 and 35 degrees C. The exercise test (ET) consisted of 2 exercise bouts separated by 2 h of rest in their boxes. Blood samples were taken before, during and after the second exercise bout and muscle (m. gluteus medius) biopsies were taken before the first exercise bout and after an intensive trot over 2600 m in the second exercise bout. The blood samples were analysed for plasma potassium and total plasma protein concentration (TPP) and the muscle fibres were analysed for elemental composition by x-ray microanalysis. The intracellular content was as follows: sodium (Na) = 40 +/- 7; magnesium (Mg) = 32 +/- 4; phosphorus (P) = 282 +/- 15; sulphur (S) = 222 +/- 13; chloride (Cl) = 119 +/- 31; potassium (K) = 304 +/- 21 and calcium (Ca) = 8 +/- 2 mmol/kg dry weight under resting conditions. Intracellular potassium content increased after exercise compared to resting values. There was a good correlation between exercise intensity, plasma potassium concentration and shifts in plasma volume, indicated by alterations in TPP. This probably reflects the very fast shift of potassium and fluid between muscle and plasma. Plasma potassium concentrations decreased below resting values post exercise. The higher dehydration degree and potassium sweat loss after exercise at 35 degrees C was not reflected in lower muscular potassium content, but by a lower plasma potassium/total plasma protein ratio after exercise, indicating less circulating potassium.

  6. Development of Electrode Units for Electrokinetic Desalination of Masonry and Pilot Scale Test at Three locations for Removal of Chlorides

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Christensen, Iben Vernegren; Skibsted, Gry

    2010-01-01

    Electrode units for electrokinetic desalination of masonry has been developed and tested in pilot scale at three different locations. The units are formed as casings with a metallic mesh electrode, and carbonate rich clay to buffer the acid produced at the anode. The case has an extra loose bottom...... which allows continuous pressure between clay and masonry so good electrical contact is remained. The electrode units were tested at three different locations, two on baked brick masonry (inside in a heated room and outside on a masonry with severe plaster peeling) and the third pilot scale experiment...

  7. Chloride in diet

    Science.gov (United States)

    ... vegetables. Foods with higher amounts of chloride include seaweed, rye, tomatoes, lettuce, celery, and olives. Chloride, combined ... RDA is an intake level based on scientific research evidence. Adequate Intake (AI): This level is established ...

  8. Systematic review focusing on the excretion and protection roles of sweat in the skin.

    Science.gov (United States)

    Peng, Yan; Cui, Xiao; Liu, Yanhua; Li, Yaoyin; Liu, Jian; Cheng, Biao

    2014-01-01

    The skin excretes substances primarily through sweat glands. Several conditions have been demonstrated to be associated with diminished sweating. However, few studies have concentrated on the metabolism and excretion of sweat. This review focuses on the relationship between temperature and the thermoregulatory efficacy of sweat, and then discusses the excretion of sweat, which includes the metabolism of water, minerals, proteins, vitamins as well as toxic substances. The potential role of sweat secretion in hormone homeostasis and the effects on the defense system of the skin are also clarified. © 2014 S. Karger AG, Basel.

  9. New functions and applications of walter, the sweating fabric manikin.

    Science.gov (United States)

    Fan, Jintu; Qian, Xiaoming

    2004-09-01

    In this paper, latest developments on Walter, a sweating fabric manikin, are reported. These include the improved simulation of "walking motion", the design and construction of an automated water supply, and real-time measurement of evaporative water loss and regulation of "skin" temperature through the regulation of the pumps inside the manikin body. Testing of commercial garment ensembles showed that the measurement of thermal insulation and moisture-vapour resistance of clothing is very reproducible with the coefficient of variation being generally less than 5%. It was also shown that, in addition to the thermal insulation and moisture-vapour resistance, the percentage of moisture accumulation within clothing is a very useful parameter of clothing comfort. The improved manikin has been used to investigate the effects of walking motion on thermal insulation and evaporative resistance of clothing. The trend of the effects of walking speed up to 1.13 m s(-1) for the nude manikin and when it was wearing garments of different sizes are reported.

  10. Early-stage mucinous sweat gland adenocarcinoma of eyelid

    Directory of Open Access Journals (Sweden)

    Nizawa T

    2011-05-01

    Full Text Available Tomohiro Nizawa1, Toshiyuki Oshitari1, Ryuta Kimoto1, Fusae Kajita1, Jiro Yotsukura1, Kaoru Asanagi1, Takayuki Baba1, Yoko Takahashi2, Takashi Oide2, Takako Kiyokawa2, Takashi Kishimoto2, Shuichi Yamamoto11Department of Ophthalmology and Visual Science, 2Department of Molecular Pathology, Chiba University Graduate School of Medicine, Chuo-ku, Chiba, JapanAbstract: We present the findings of an early-stage primary mucinous sweat gland adenocarcinoma in the lower eyelid of a Japanese patient. The patient was a 73-year-old man who had had a nodule on the left lower eyelid for two years. He was referred to our hospital with a diagnosis of a swollen chalazion. The clinical and histopathological records were reviewed and the mass was excised. Histopathological examination revealed a mucinous sweat gland adenocarcinoma. Postoperative magnetic resonance imaging and positron emission tomography excluded systemic metastases. After the histopathological findings, a complete surgical excision of the margins of the adenocarcinoma was performed, with histopathological confirmation of negative margins. After the final histopathological examination, the patient was diagnosed with a primary mucinous sweat gland adenocarcinoma of the left eyelid. Six months after the surgery, no recurrence has been observed. Because the appearance of mucinous sweat gland adenocarcinoma of the eyelid is quite variable, the final diagnosis can only be made by histopathological examination. A complete surgical excision is recommended.Keywords: complete surgical excision, eyelid, initial stage, mucinous sweat gland adenocarcinoma

  11. Sweat mineral-element responses during 7 h of exercise-heat stress.

    Science.gov (United States)

    Montain, Scott J; Cheuvront, Samuel N; Lukaski, Henry C

    2007-12-01

    Uncertainty exists regarding the effect of sustained sweating on sweat mineral-element composition. To determine the effect of multiple hours of exercise-heat stress on sweat mineral concentrations. Seven heat-acclimated subjects (6 males, 1 female) completed 5 x 60 min of treadmill exercise (1.56 m/s, 2% grade) with 20 min rest between exercise periods in 2 weather conditions (27 degrees C, 40% relative humidity, 1 m/s and 35 degrees C, 30%, 1 m/s). Sweat was collected from a sweat-collection pouch attached to the upper back during exercise bouts 1, 3, and 5. Mineral elements were determined by using inductively coupled plasma-emission spectrography. At 27 degrees C, sweat sodium (863 [563] microg/mL; mean [SD]), potassium (222 [48] microg/mL), calcium (16 [7]) microg/mL), magnesium (1265 [566] ng/mL), and copper (80 [56] ng/mL) remained similar to baseline over 7 h of exercise-heat stress, whereas sweat zinc declined 42-45% after the initial hour of exercise-heat stress (Ex1 = 655 [362], Ex3 = 382 [168], Ex5 = 355 [288] microg/mL, P sweat zinc at 35 degrees C when sweat rates were higher. Sweat rate had no effect on sweat trace-element composition. Sweat sodium, potassium, and calcium losses during multiple hours of sustained sweating can be predicted from initial sweat composition. Estimates of sweat zinc losses, however, will be overestimated if sweat zinc conservation is not accounted for in sweat zinc-loss estimates.

  12. Sweat, the driving force behind normal skin: an emerging perspective on functional biology and regulatory mechanisms.

    Science.gov (United States)

    Murota, Hiroyuki; Matsui, Saki; Ono, Emi; Kijima, Akiko; Kikuta, Junichi; Ishii, Masaru; Katayama, Ichiro

    2015-01-01

    The various symptoms associated with excessive or insufficient perspiration can significantly reduce a patient's quality of life. If a versatile and minimally invasive method could be established for returning sweat activity to normalcy, there is no question that it could be used in the treatment of many diseases that are believed to involve perspiration. For this reason, based on an understanding of the sweat-gland control function and sweat activity, it was necessary to conduct a comprehensive search for the factors that control sweating, such as the central and peripheral nerves that control sweat-gland function, the microenvironment surrounding the sweat glands, and lifestyle. We focused on the mechanism by which atopic dermatitis leads to hypohidrosis and confirmed that histamine inhibits acetylcholinergic sweating. Acetylcholine promotes the phosphorylation of glycogen synthesis kinase 3β (GSK3β) in the sweat-gland secretory cells and leads to sensible perspiration. By suppressing the phosphorylation of GSK3β, histamine inhibits the movement of sweat from the sweat-gland secretory cells through the sweat ducts, which could presumably be demonstrated by dynamic observations of the sweat glands using two-photon microscopy. It is expected that the discovery of new factors that control sweat-gland function can contribute to the treatment of diseases associated with dyshidrosis. Copyright © 2014 Japanese Society for Investigative Dermatology. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Cadmium concentrations in the testes, sperm, and spermatids of mice subjected to long-term cadmium chloride exposure.

    Science.gov (United States)

    Bench, G; Corzett, M H; Martinelli, R; Balhorn, R

    1999-01-01

    Exposures to cadmium have been reported to reduce male fertility and there are several hypotheses that suggest how reduced male fertility may result from incorporation of cadmium into sperm chromatin. The purpose of this study was to determine whether mice subjected to long-term intraperitoneal cadmium exposure incorporated cadmium into their sperm chromatin. Male mice were exposed to 0.1 mg/kg body weight cadmium in the form of CdCl2 via intraperitoneal injection once per week for 4, 10, 26, and 52 weeks and then sacrificed. The cadmium contents of the liver, testes, pooled sperm, and pooled spermatids from dosed and control animals were determined by atomic absorption spectroscopy. Cadmium and zinc contents in individual sperm and spermatid heads were determined by particle-induced x-ray emission. Atomic absorption spectroscopy revealed that although cadmium accumulated in the liver and testes, cadmium was not detected in pooled sperm or spermatid samples down to minimum detectable limits of 0.02 microg/g dry weight. Particle-induced x-ray emission analyses did not show the presence of cadmium in any sperm or spermatid head down to minimum detectable limits of 15 microg/g dry weight. Particle-induced x-ray emission analyses also demonstrated that phosphorus, sulfur, and zinc concentrations in individual sperm and spermatid heads were not altered by exposure to CdCl2. Because cadmium was not incorporated into sperm chromatin at levels above 0.02 microg/g dry weight, the data cast doubt on hypotheses that suggest that reduced male fertility may result from incorporation of cadmium into sperm chromatin.

  14. Excretion of ciprofloxacin in sweat and multiresistant Staphylococcus epidermidis

    DEFF Research Database (Denmark)

    Høiby, N; Jarløv, J O; Kemp, M

    1997-01-01

    BACKGROUND: Staphylococcus epidermidis develops resistance to ciprofloxacin rapidly. That this antibiotic is excreted in apocrine and eccrine sweat of healthy individuals might be the reason for the development of such resistance. We assessed whether S epidermidis isolated from the axilla and nasal...... flora of healthy people could develop resistance to ciprofloxacin after a 1-week course of this antibiotic. METHODS: The concentration of ciprofloxacin in sweat was measured in seven volunteers after oral administration of 750 mg ciprofloxacin twice daily for 7 days, and the development of resistance...... in S epidermidis from axilla and nostrils was monitored during and 2 months after the treatment. Genotyping of S epidermidis was done by restriction fragment length polymorphism. FINDINGS: The mean concentration of ciprofloxacin in sweat increased during the 7 days of treatment-from 2.2 micrograms/mL 2...

  15. Effect of induced metabolic alkalosis on sweat composition in men.

    Science.gov (United States)

    Patterson, M J; Galloway, Stuart D R; Nimmo, M A

    2002-01-01

    To determine whether induced metabolic alkalosis affects sweat composition, 10 males cycled for 90 min at 62.5 +/- 1.3% peak oxygen uptake, on two separate occasions. Subjects ingested either empty capsules (placebo) or capsules containing NaHCO3- (0.3 g kg-1 body mass; six equal doses) over a 2-h period, which commenced 3 h prior to exercise. Arterialized-venous blood samples were drawn prior to and after 15, 30, 60 and 90 min of exercise. Sweat was aspirated at the end of exercise from a patch located on the right scapula region. NaHCO3- ingestion elevated blood pH, [HCO3-] and serum [Na+], whereas serum [Cl-] and [K+] were reduced, both at rest and during exercise (P Sweat pH was greater in the NaHCO3- trial (6.24 +/- 0.18 vs. 6.38 +/- 0.18; P sweat [Na+] (49.5 +/- 4.8 vs. 50.2 +/- 4.3 mEq L-1), [Cl-] (37.5 +/- 5.1 vs. 39.3 +/- 4.2 mEq L-1) and [K+] (4.66 +/- 0.19 vs. 4.64 +/- 0.34 mEq L-1) did not differ between trials (P > 0.05). Sweat [HCO3-] (2.49 +/- 0.58 vs. 3.73 +/- 1.10 mEq L-1) and [lactate] (8.92 +/- 0.79 vs. 10.51 +/- 0.32 mmol L-1) tended to be greater after NaHCO3- ingestion, although significance was not reached (P=0.07 and P=0.08, respectively). These data indicate that induced metabolic alkalosis can modify sweat composition, although it is unclear whether the secretory coil, reabsorptive duct, or both are responsible for this alteration.

  16. [Analysis of fatty acid composition of sweat lipids in children and adults with skin disease].

    Science.gov (United States)

    Andrashko, Iu V; Koliadenko, V G; Briuzgina, T S; Prokhorova, M P

    2002-01-01

    Gas-chromatographic analysis of fatty acid composition of sweat lipids in children and adults with neurodermatitis, atopic dermatitis, and eczema showed that sweat can be used as a new noninvasive biological object for evaluation of lipid metabolism disorders.

  17. Effect of Low Dose Lead (Pb) Administration on Tail Immersion Test and Formalin-induced Pain in Wistar Rats: Possible Modulatory Role of Cobalt (II) Chloride.

    Science.gov (United States)

    Umar, A H; Suleiman, I; Muhammed, H

    2017-03-06

    Lead (Pb) is cheap and there is a long tradition of its use, but its toxic effects have also been recognized. There is increased public health concern regarding the hazards of low dose Pb exposure to adults and children. Studies have shown the risks for hypertension, decrements in renal function, subtle decline in cognitive function, and adverse reproductive outcome at low blood Pb level. In this study, the possible modulatory role of cobalt (II) chloride (CoCl2) on low level Pb exposure on tail immersion test and formalin induced pain was investigated. Twenty adult Wistar rats of both sexes (weight 150g to 200g) were used. The animals were divided into four groups (n = 5) and administered Pb (5mg/kg), Pb (5mg/kg) + CoCl2 (50mg/kg) and CoCl2 (50mg/kg) orally for twenty-eight days. The last group served as control and were given distilled water only. In the tail immersion test, there was no significant change in reaction time for all three groups when compared to the control. In the formalin-induced pain, pain score after five and forty-five minutes also do not show significant change for all the three groups when compared to control. This work suggested that exposure to 5mg/kg Pb for twenty-eight days do not significantly impair reaction time in tail immersion test and pain score in formalin induced pain in Wistar rats. Also, administration of 50mg/kg CoCl2 do not improve performance of the animals in the experiments.

  18. Testing the Hydrological Landscape Unit Classification System and Other Terrain Analysis Measures for Predicting Low-Flow Nitrate and Chloride in Watersheds

    Science.gov (United States)

    Poor, Cara J.; McDonnell, Jeffrey J.; Bolte, John

    2008-11-01

    Elevated nitrate concentrations in streamwater are a major environmental management problem. While land use exerts a large control on stream nitrate, hydrology often plays an equally important role. To date, predictions of low-flow nitrate in ungauged watersheds have been poor because of the difficulty in describing the uniqueness of watershed hydrology over large areas. Clearly, hydrologic response varies depending on the states and stocks of water, flow pathways, and residence times. How to capture the dominant hydrological controls that combine with land use to define streamwater nitrate concentration is a major research challenge. This paper tests the new Hydrologic Landscape Regions (HLRs) watershed classification scheme of Wolock and others (Environmental Management 34:S71-S88, 2004) to address the question: Can HLRs be used as a way to predict low-flow nitrate? We also test a number of other indexes including inverse-distance weighting of land use and the well-known topographic index (TI) to address the question: How do other terrain and land use measures compare to HLR in terms of their ability to predict low-flow nitrate concentration? We test this for 76 watersheds in western Oregon using the U.S. Environmental Protection Agency’s Environmental Monitoring and Assessment Program and Regional Environmental Monitoring and Assessment Program data. We found that HLRs did not significantly improve nitrate predictions beyond the standard TI and land-use metrics. Using TI and inverse-distance weighting did not improve nitrate predictions; the best models were the percentage land use—elevation models. We did, however, see an improvement of chloride predictions using HLRs, TI, and inverse-distance weighting; adding HLRs and TI significantly improved model predictions and the best models used inverse-distance weighting and elevation. One interesting result of this study is elevation consistently predicted nitrate better than TI or the hydrologic classification

  19. Sweat sodium loss influences serum sodium concentration in a marathon.

    Science.gov (United States)

    Lara, B; Salinero, J J; Areces, F; Ruiz-Vicente, D; Gallo-Salazar, C; Abián-Vicén, J; Del Coso, J

    2017-02-01

    The aim of this investigation was to determine the influence of sweat electrolyte concentration on body water and electrolyte homeostasis during a marathon. Fifty-one runners completed a marathon race in a warm and dry environment (24.4 ± 3.6 °C). Runners were classified as low-salt sweaters (n = 21; sweat Na + concentration), typical sweaters (n = 20; ≥30 and sweat Na + concentration), and salty sweaters (n = 10; ≥60 mmol/L of sweat Na + concentration). Before and after the race, body mass and a sample of venous blood were obtained. During the race, sweat samples were collected by using sweat patches, and fluid and electrolyte intake were recorded by using self-reported questionnaires. Low-salt, typical and salty sweaters presented similar sweat rates (0.93 ± 0.2, 0.92 ± 0.29, 0.99 ± 0.21 L/h, respectively), body mass changes (-3.0 ± 1.0, -3.3 ± 1.0, -3.2 ± 0.8%), total Na + intake (12.7 ± 8.1, 11.5 ± 9.7, 14.5 ± 16.6 mmol), and fluid intake (1.3 ± 0.8, 1.2 ± 0.8, 1.2 ± 0.6 L) during the race. However, salty sweaters presented lower post-race serum Na + concentration (140.8 ± 1.3 vs 142.5 ± 1.1, 142.4 ± 1.4 mmol/L; P Sweat electrolyte concentration could influence post-race serum electrolyte concentration in the marathon. However, even the saltiest sweaters did not develop exercise-associated hyponatremia or associated symptoms. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Bullous lesions, sweat gland necrosis and rhabdomyolysis in alcoholic coma

    Directory of Open Access Journals (Sweden)

    Neelakandhan Asokan

    2014-01-01

    Full Text Available A 42-year-old male developed hemorrhagic bullae and erosions while in alcohol induced coma. The lesions were limited to areas of the body in prolonged contact with the ground in the comatose state. He developed rhabdomyolysis, progressing to acute renal failure (ARF. Histopathological examination of the skin showed spongiosis, intraepidermal vesicles, and necrosis of eccrine sweat glands with denudation of secretory epithelial lining cells. With supportive treatment and hemodialysis, the patient recovered in 3 weeks time. This is the first reported case of bullous lesions and sweat gland necrosis occurring in alcohol-induced coma complicated by rhabdomyolysis and ARF.

  1. Wearable technologies for sweat rate and conductivity sensors

    CERN Document Server

    Salvo, Pietro

    2012-01-01

    Hauptbeschreibung Wearable sensors present a new frontier in the development of monitoring techniques. They are of great importance in sectors such as sports and healthcare, as they permit the continuous monitoring of physiological and biological elements, such as ECG and human sweat. Until recently, this could only be carried out in specialized laboratories in the presence of cumbersome, and usually, expensive devices. Sweat monitoring sensors integrated onto textile substrates are not only part of a new field of work but, they also represent the first attempt to implement such an

  2. Simple barcode system based on ionogels for real time pH-sweat monitoring

    OpenAIRE

    Benito-Lopez, Fernando; Coyle, Shirley; Byrne, Robert; O’Toole, Corinne; Barry, Caroline; Diamond, Dermot

    2010-01-01

    This paper presents the fabrication, characterization and the performance of a wearable, robust, flexible and disposable barcode system based on novel ionic liquid polymer gels (ionogels) for monitoring in real time mode the pH of the sweat generated during an exercise period. Up to now sweat analysis has been carried out using awkward methods of collecting sweat followed by laboratory analysis. The approach presented here can provide immediate feedback regarding sweat composition. The great ...

  3. Sweat it Out : Johannes de Gorter and Sudorifics in the Dutch Republic

    NARCIS (Netherlands)

    Verwaal, Ruben

    2017-01-01

    Today, many go for a run, cover themselves under blankets, or sit in the sauna believing that they can ‘sweat out’ the common cold. Whereas modern medicine has falsified the efficacy of sweating as treatment, this paper considers the development of medical research about sweating in the early modern

  4. Crying for a Vision: The Native American Sweat Lodge Ceremony as Therapeutic Intervention

    Science.gov (United States)

    Garrett, Michael Tlanusta; Torres-Rivera, Edil; Brubaker, Michael; Portman, Tarrell Awe Agahe; Brotherton, Dale; West-Olatunji, Cirecie; Conwill, William; Grayshield, Lisa

    2011-01-01

    The Native American sweat lodge ceremony or sweat therapy is being used increasingly in various medical, mental health, correctional, and substance abuse treatment centers serving both Native and non-Native clients. This article explores the sweat lodge ceremony's background, elements of Native American spirituality, origin story, cultural…

  5. Artificial sweat composition to grow and sustain a mixed human axillary microbiome.

    Science.gov (United States)

    Callewaert, Chris; Buysschaert, Benjamin; Vossen, Els; Fievez, Veerle; Van de Wiele, Tom; Boon, Nico

    2014-08-01

    A novel artificial sweat composition, Skin Community Interaction simulation, designed to mimic the human axillary sweat, was compared to other artificial sweat compositions. Axillary microbiota grown in the novel composition closely resembled the original community. Volatile organic compound analysis showed good correlations with in vivo axillary (mal)odor components. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Effects of stimulation technique, anatomical region and time on human sweat lipid mediator profiles.

    Science.gov (United States)

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n = 7) was collected weekly for three weeks from the volar forearm following either pilocarpine ion...

  7. Pituitary adenylate cyclase-activating polypeptide promotes eccrine gland sweat secretion

    DEFF Research Database (Denmark)

    Sasaki, S; Watanabe, J; Ohtaki, H

    2017-01-01

    BACKGROUND: Sweat secretion is the major function of eccrine sweat glands; when this process is disturbed (paridrosis), serious skin problems can arise. To elucidate the causes of paridrosis, an improved understanding of the regulation, mechanisms and factors underlying sweat production is requir...

  8. Can the diagnostic reliability of the thrombin generation test as a global haemostasis assay be improved? The impact of calcium chloride concentration.

    Science.gov (United States)

    Parunov, L A; Surov, S S; Liang, Y; Lee, T K; Ovanesov, M V

    2017-05-01

    Thrombin generation test (TGT) is a global haemostasis assay with a potential to predict bleeding tendencies and treatment effects in patients with haemophilia. Despite 15 years of clinical research, the diagnostic value of TGT remains controversial, possibly due to suboptimal sensitivity to coagulation deficiencies, robustness and reproducibility. The goal of this study was to explore the effect of calcium chloride (CaCl2 ) concentration on the TGT's response to intrinsic coagulation factors (F) VIII, IX and XIa. Normal and factor-deficient plasmas supplemented with lacking coagulation factor and different CaCl2 levels were tested by calibrated thrombinography assay. Thrombin peak height (TPH) was strongly CaCl2 dependent, increasing sharply from no TG at 5 mm to a peak at 13.8 mm of CaCl2 (95% confidence interval [CI]: 13.0, 14.5) in normal and normalized deficient plasmas and at 11.9 mm (CI: 9.7, 14.2) in deficient plasmas, and then decreasing slowly to a complete inhibition at 30-40 mm. In contrast, TG lag time, time to peak and endogenous thrombin potential were nearly insensitive to CaCl2 concentrations between 10 and 20 mm. The maximal difference between the TPH in deficient and supplemented plasmas was observed at 15.5 mm (CI: 12.8, 18.1). Variations in CaCl2 concentration in the assay mixture and sodium citrate concentrations in patient plasma samples may affect TGT responses, sensitivity and result in increased inter- and intra-laboratory variance. Implementation of TGT by clinical and quality control laboratories may require optimization of CaCl2 concentration. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  9. Evaporimeter and Bubble-Imaging Measures of Sweat Gland Secretion Rates.

    Science.gov (United States)

    Kim, Jeeyeon; Farahmand, Miesha; Dunn, Colleen; Davies, Zoe; Frisbee, Eric; Milla, Carlos; Wine, Jeffrey J

    2016-01-01

    Beta-adrenergically-stimulated sweat rates determined by evaporimetry or by sweat bubble imaging are useful for measuring CFTR function because they provide a near-linear readout across almost the full range of CFTR function. They differentiate cystic fibrosis (CF) subjects from CF carriers and carriers from controls. However, evaporimetry, unlike bubble imaging, appears to be unable to detect improved levels of CFTR function in G551D subjects taking the CFTR modulator ivacaftor. Here, we quantify the sensitivity of evaporimetry and bubble imaging methods for assessing low levels of CFTR-dependent sweat rates. To establish sensitivity, we did dose-ranging studies using intradermally injected [cAMP]i-elevating cocktails. We reduced isoproterenol/aminophylline levels while maintaining a high level of atropine to block muscarinic elevation of [Ca2+]i. We stimulated the same sets of glands for both assays and recorded responses for 20 min. In response to a 3-log dilution of the stimulating cocktail (0.1%), bubble responses were detected in 12/12 tests (100%), with 49% ± 3% of glands secreting to produce an aggregate volume of 598 nl across the 12, 20-min tests. This was ~5% of the response to full cocktail. Evaporimetry detected responses in 3/12 (25%) tests with an aggregate secretion volume of 175 nl. After stimulation with a still more dilute cocktail (0.03%), bubble imaging detected 15 ± 13% of glands secreting at a rate ~0.9% of the response to full cocktail, while zero responding was seen with evaporimetry. The bubble imaging method detected secretion down to aggregate rates of bubble imaging may be required to detect small but physiologically important increases in secretion rates produced by CFTR modulators.

  10. [Headspace GC/MS analysis of residual vinyl chloride and vinylidene chloride in polyvinyl chloride and polyvinylidene chloride products].

    Science.gov (United States)

    Ohno, Hiroyuki; Mutsuga, Motoh; Kawamura, Yoko; Suzuki, Masako; Aoyama, Taiki

    2005-02-01

    A headspace GC/MS analysis method for the simultaneous determination of residual vinyl chloride (VC) and vinylidene chloride (VDC) in polyvinyl chloride (PVC) and polyvinylidene chloride (PVDC) products was developed. A test sample was swelled overnight with N,N-dimethylacetamide in a sealed vial. The vial was incubated for 1 hour at 90 degrees C, then the headspace gas was analyzed by GC/MS using a PLOT capillary column. The recoveries from spiked PVC and PVDC samples were 90.0-112.3% for VC and 85.2-108.3% for VDC. The determination limits were 0.01 microg/g for VC and 0.06/microg/g for VDC, respectively. By this method, VC was detected in two PVC water supply pipes at the levels of 0.61 and 0.01 microg/g. On the other hand, VC and VDC were not detected in any of the food container-packages or toys tested.

  11. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents the state-of-the art: an analytical model which describes chloride profiles in concrete as function of depth...... dependent surface chloride concentrations and the diffusion coefficients. Model parameters for Portland cement concretes with and without silica fume and fly ash in marine atmospheric and submerged South Scandinavian environment are suggested in a companion paper based on 10 years field exposure data....... makes physical sense for the design engineer, i.e. the achieved chloride diffusion coefficients at 1 year and 100 years, D1 and D100 respectively, and the corresponding achieved chloride concentrations at the exposed concrete surface, C1 and C100. Data from field exposure supports the assumption of time...

  12. The Sweat Lodge Ceremony in Challenge/Adventure Programming.

    Science.gov (United States)

    Quinn, William J.; Smith, Thomas E.

    This paper advocates the potentials of "sweat lodge" rituals for adventure education programs. Historically, rituals and ceremonies have been instrumental in passing major philosophical and sociological paradigms from one generation to the next. However, there is little theory and research about how ritual and ceremony results in the…

  13. Do elephants need to sweat? | Wright | African Zoology

    African Journals Online (AJOL)

    An adequate rate of evaporative water loss is considered essential for the maintenance of thermal balance in the elephant in warm climatic conditions. Histological studies have failed to reveal the existence of sweat glands in elephant skin. Transepidermal water-loss rate has been measured and shown to be sufficiently ...

  14. the comfort, measured by means of a sweating manikin (waltertm)

    African Journals Online (AJOL)

    user

    Anton F Botha*, Marguerite E Stoffberg & Lawrance Hunter. ABSTRACT. With the growing importance of clothing comfort in South African and overseas markets for locally produced clothing, the Council for. Scientific Industrial Research (CSIR) acquired an advanced sweating fabric manikin for measuring clothing comfort.

  15. Sweating, thirst perception and plasma electrolyte composition in ...

    African Journals Online (AJOL)

    Thirst is a perception, the subjective experience evoked by fluid deficits. Exercise induces sweating and subsequently electrolyte loss and thirst but there is little documented on post exercise thirst perception in women of varying body mass indices. 40 apparently healthy young women (19-25years) in the follicular phase of ...

  16. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents experimentally based design parameters for Portland cement concretes with and without silica fume and fly ash...... in marine atmospheric and submersed South Scandinavian environment. The design parameters are based on sequential measurements of 86 chloride profiles taken over ten years from 13 different types of concrete. The design parameters provide the input for an analytical model for chloride profiles as function...

  17. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    OpenAIRE

    Meyer,F.; Laitano,O.; Bar-Or,O.; McDougall,D.; Heigenhauser,G.J.F.

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42ºC, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During b...

  18. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    OpenAIRE

    Meyer, Flavia; Lionello Neto, Orlando Laitano

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42ºC, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject’s lower back. During b...

  19. Hydration and sweating responses to hot-weather football competition.

    Science.gov (United States)

    Kurdak, S S; Shirreffs, S M; Maughan, R J; Ozgünen, K T; Zeren, C; Korkmaz, S; Yazici, Z; Ersöz, G; Binnet, M S; Dvorak, J

    2010-10-01

    During a football match played in warm (34.3 ± 0.6 °C), humid (64 ± 2% rh) conditions, 22 male players had their pre-match hydration status, body mass change, sweat loss and drinking behavior assessed. Pre-match urine specific gravity (1.012 ± 0.006) suggested that all but three players commenced the match euhydrated. Players lost 3.1 ± 0.6 L of sweat and 45 ± 9 mmol of sodium during the 90-min match and replaced 55 ± 19% of their sweat losses and hence by the end of the game were 2.2 ± 0.9% lighter. The water volume consumed during the game was highly variable (1653 ± 487 mL; 741-2387 mL) but there was a stronger relationship between the estimated pre-game hydration status and water volume consumed, than between sweat rate and water volume consumed. In a second match, with the same players 2 weeks later in 34.4 ± 0.6 °C, 65 ± 3% rh, 11 players had a sports drink available to them before and during the match in addition to water. Total drink volume consumed during the match was the same, but approximately half the volume was consumed as sports drink. The results indicate that substantial sweat water and electrolyte losses can occur during match play in hot conditions and a substantial water and sodium deficit can occur in many players even when water or sports drink is freely available. © 2010 John Wiley & Sons A/S.

  20. Endoscopic lumbar sympathectomy for women: effect on compensatory sweat

    Directory of Open Access Journals (Sweden)

    Marcelo de Paula Loureiro

    2008-01-01

    Full Text Available INTRODUCTION: Plantar hyperhidrosis is present in 50% of patients with hyperhidrosis. Thoracic sympathectomy is an important tool for the treatment of this condition, which is successful in about 60% of patients. For the remaining patients, lumbar sympathectomy is the procedure of choice. As new minimally invasive techniques have been developed, a significant demand for this type of access has led to its adaptation to the lumbar sympathectomy. The objective of this study was to evaluate the effectiveness of endoscopic retroperitoneal lumbar sympathectomy in controlling plantar hyperhidrosis and its effects on compensatory sweat. MATERIALS AND METHODS: Thirty female patients with persistent plantar hyperhidrosis after thoracic sympathectomy were enrolled. They were randomly assigned to laparoscopic retroperitoneal lumbar sympathectomy (Group A or no surgical intervention (Group B - control groups. Quality-of-life modifications were assessed by specific questionnaires before and after surgery. In the same manner, direct sweat measurements were also performed pre- and post-intervention by evaluating trans-epidermal water loss. Despite the lack of intervention, the control group was evaluated at similar timepoints. RESULTS: In Group A, no major complications occurred in the peri-operative period. During the immediate post-operative period, three patients (20% experienced prolonged pain (more than ten days. Eight patients suffered from worsened compensatory sweating (53.3%. In Group A, after lumbar sympathectomy, the quality of life significantly improved (p<0.05, intra-group comparison beyond that of the control group (p<0.05, inter-group comparison. Also, lumbar sympathectomy resulted in significantly lower values of foot sweat (pre- vs. post-operative periods, p<0.05; Group A vs. Group B, p<0.05. These patients also developed higher values of sweat measurements on specific points of their dorsal and abdominal regions after the procedure (p<0

  1. Thermoregulation, Fluid Balance, and Sweat Losses in American Football Players.

    Science.gov (United States)

    Davis, Jon K; Baker, Lindsay B; Barnes, Kelly; Ungaro, Corey; Stofan, John

    2016-10-01

    Numerous studies have reported on the thermoregulation and hydration challenges athletes face in team and individual sports during exercise in the heat. Comparatively less research, however, has been conducted on the American Football player. Therefore, the purpose of this article is to review data collected in laboratory and field studies and discuss the thermoregulation, fluid balance, and sweat losses of American Football players. American Football presents a unique challenge to thermoregulation compared with other sports because of the encapsulating nature of the required protective equipment, large body size of players, and preseason practice occurring during the hottest time of year. Epidemiological studies report disproportionately higher rates of exertional heat illness and heat stroke in American Football compared with other sports. Specifically, larger players (e.g., linemen) are at increased risk for heat ailments compared with smaller players (e.g., backs) because of greater body mass index, increased body fat, lower surface area to body mass ratio, lower aerobic capacity, and the stationary nature of the position, which can reduce heat dissipation. A consistent finding across studies is that larger players exhibit higher sweating rates than smaller players. Mean sweating rates from 1.0 to 2.9 L/h have been reported for college and professional American Football players, with several studies reporting 3.0 L/h or more in some larger players. Sweat sodium concentration of American Football players does not seem to differ from that of athletes in other sports; however, given the high volume of sweat loss, the potential for sodium loss is higher in American Football than in other sports. Despite high sweating rates with American Football players, the observed disturbances in fluid balance have generally been mild (mean body mass loss ≤2 %). The majority of field-based studies have been conducted in the northeastern part of the United States, with limited

  2. Influence of Chloride-Ion Adsorption Agent on Chloride Ions in Concrete and Mortar.

    Science.gov (United States)

    Peng, Gai-Fei; Feng, Nai-Qian; Song, Qi-Ming

    2014-04-30

    The influence of a chloride-ion adsorption agent (Cl agent in short), composed of zeolite, calcium aluminate hydrate and calcium nitrite, on the ingress of chloride ions into concrete and mortar has been experimentally studied. The permeability of concrete was measured, and the chloride ion content in mortar was tested. The experimental results reveal that the Cl agent could adsorb chloride ions effectively, which had penetrated into concrete and mortar. When the Cl agent was used at a dosage of 6% by mass of cementitious materials in mortar, the resistance to the penetration of chloride ions could be improved greatly, which was more pronounced when a combination of the Cl agent and fly ash or slag was employed. Such an effect is not the result of the low permeability of the mortar, but might be a result of the interaction between the Cl agent and the chloride ions penetrated into the mortar. There are two possible mechanisms for the interaction between the Cl agent and chloride ion ingress. One is the reaction between calcium aluminate hydrate in the Cl agent and chloride ions to form Friedel's salt, and the other one is that calcium aluminate hydrate reacts with calcium nitrite to form AFm during the early-age hydration of mortar and later the NO₂(-) in AFm is replaced by chloride ions, which then penetrate into the mortar, also forming Friedel's salt. More research is needed to confirm the mechanisms.

  3. A case of radiation myelopathy with characteristic findings of thermoregulatory sweat distribution and magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Katsumasa; Sannomiya, Kunihiro; Nagao, Shinichiro; Nakazato, Okifumi; Tsuda, Tomiyasu (Oita Medical University, Hazama (Japan))

    1993-09-01

    A 73-year-old man had undergone resection of a lung carcinoma of the right upper lobe in 1987. Post-operative irradiation (40 Gy) was given to the right hilus. In November 1988, recurrence was detected in the trachea. Laser therapy was done in December 1988. From January 9 to February 13 in 1989, irradiation (50 Gy) was given to the mediastinum. From the beginning of 1991, the patient developed muscle weakness in the right lower extremity and pain temperature sensations were impaired below the Th12 level on the left side. On October 3, 1991, he was admitted to our hospital. Neurological examination revealed mild muscle weakness in the right lower extremity. Superficial sensations were impaired below the Th6 level bilaterally. Deep tendon reflexes were hyperactive in the lower extremities. A bilateral Babinski sign was positive. The T1 weighted MRI showed a low signal intensity in the spinal cord at the level of thoracic vertebra (TV)2-TV6. T2 weighted images revealed a high signal intensity area of the spinal cord from TV4-TV6. A gadolinium-DTPA injection revealed an enhancement on the left side of the spinal cord at the TV2-3 level, and right side of the spinal cord at the TV4-5 level on the sagittal and axial images. A thermal sweating test revealed hypohidrosis below the Th8 level on the right side, and the Th11 level on the left side. Sweating was delayed at the Th7-8 levels on the right side and Th10-11 levels on the left side. An irradiated field on the chest revealed hypohidrosis. There were differences between spinal lesions in MRI and thermoregulatory sweat distribution. Sweat distribution of this case could not be explained by damage of intermediolateral nucleus of the spinal cord. We speculated that the sympathetic sudomotor pathways were partially disturbed at the upper thoracic cord. But the exact mechanism could not been elucidated. (author).

  4. 3D modeling and characterization of a calorimetric flow rate sensor for sweat rate sensing applications

    Science.gov (United States)

    Iftekhar, Ahmed Tashfin; Ho, Jenny Che-Ting; Mellinger, Axel; Kaya, Tolga

    2017-03-01

    Sweat-based physiological monitoring has been intensively explored in the last decade with the hopes of developing real-time hydration monitoring devices. Although the content of sweat (electrolytes, lactate, urea, etc.) provides significant information about the physiology, it is also very important to know the rate of sweat at the time of sweat content measurements because the sweat rate is known to alter the concentrations of sweat compounds. We developed a calorimetric based flow rate sensor using PolydimethylSiloxane that is suitable for sweat rate applications. Our simple approach on using temperature-based flow rate detection can easily be adapted to multiple sweat collection and analysis devices. Moreover, we have developed a 3D finite element analysis model of the device using COMSOL Multiphysics™ and verified the flow rate measurements. The experiment investigated flow rate values from 0.3 μl/min up to 2.1 ml/min, which covers the human sweat rate range (0.5 μl/min-10 μl/min). The 3D model simulations and analytical model calculations covered an even wider range in order to understand the main physical mechanisms of the device. With a verified 3D model, different environmental heat conditions could be further studied to shed light on the physiology of the sweat rate.

  5. Topics in histopathology of sweat gland and sebaceous neoplasms.

    Science.gov (United States)

    Ansai, Shin-Ichi

    2017-03-01

    This article reviews several topics regarding sweat gland and sebaceous neoplasms. First, the clinicopathological characteristics of poroid neoplasms are summarized. It was recently reported that one-fourth of poroid neoplasms are composite tumors and one-fourth are apocrine type lesions. Recent progress in the immunohistochemical diagnosis of sweat gland neoplasms is also reviewed. CD117 can help to distinguish sweat gland or sebaceous tumors from other non-Merkel cell epithelial tumors of the skin. For immunohistochemical differential diagnosis between sweat gland carcinoma (SGC) other than primary cutanesous apocrine carcinoma and skin metastasis of breast carcinoma (SMBC), a panel of antibodies may be useful, including p63 (SGC+ , SMBC- ), CK5/6 (SGC+ , SMBC- ), podoplanin (SGC+ , SMBC- ) and mammaglobin (SGC- , SMBC+ ). Comparison of antibodies used for immunohistochemical diagnosis of sebaceous carcinoma (SC) suggests that adipophilin has the highest sensitivity and specificity. Some authors have found that immunostaining for survivin, androgen receptor and ZEB2/SIP1 has prognostic value for ocular SC, but not extraocular SC. In situ SC is rare, especially extraocular SC, but there have been several recent reports that actinic keratosis and Bowen's disease are the source of invasive SC. Finally, based on recent reports, classification of sebaceous neoplasms into three categories is proposed, which are sebaceoma (a benign neoplasm with well-defined architecture and no atypia), borderline sebaceous neoplasm (low-grade SC; an intermediate tumor with well-defined architecture and nuclear atypia) and SC (a malignant tumor with invasive growth and evident nuclear atypia). © 2017 Japanese Dermatological Association.

  6. Coloured sweat in two brothers: First report of familial chromhidrosis.

    Science.gov (United States)

    Gaffney, Daniel C; Cooper, Hywel L

    2016-02-01

    The uncommon diagnosis of chromhidrosis is most frequently made in young adults. This sweat gland disease, although benign, may impact significantly on the patient's quality of life. We describe the first report of familial chromhidrosis of pseudo-eccrine type (pseudochromhidrosis) occurring in two brothers aged 9 and 12 years. The classification and causality of chromhidrosis is described and approaches to assessment and management are outlined. © 2015 The Australasian College of Dermatologists.

  7. Time-of-day effect on nonthermal control of sweating response to maintained static exercise in humans.

    Science.gov (United States)

    Aoki, Ken; Kondo, Narihiko; Shimomura, Yoshihiro; Iwanaga, Koichi; Harada, Hajime; Katsuura, Tetsuo

    2002-03-01

    To investigate the influence of nonthermal factors in the time-of-day effect on the sweating response to maintained static exercise, eight healthy male subjects performed handgrip exercise at 20%, 35% and 50% maximal voluntary contraction (MVC) for 60 s at 0600 hours (morning) and at 1800 hours (evening). Oesophageal temperature ( T(oes)) before the experiment showed a diurnal rhythm [mean (SEM)] [36.3 (0.1) (morning) compared to 36.8 (0.1) degrees C (evening), Pexercise, handgrip exercise and recovery periods. The response in sweating rate (DeltaSR) on the chest and forearm to handgrip exercise increased significantly with increasing exercise intensity in both the morning and evening tests ( Pexercise intensity in the morning test ( P>0.1). During handgrip exercise at 50% MVC only, DeltaSR on the chest, forearm and palm in the evening was significantly higher than in the morning ( Pexercise were not significantly different between the morning and evening ( P>0.1). These results indicate the presence of a time-of-day effect on nonthermal control of the sweating response to isometric handgrip exercise, and that this effect is dependent on exercise intensity.

  8. Congenital Chloride Diarrhea: Diagnosis by Easy-Accessible Chloride Measurement in Feces

    Directory of Open Access Journals (Sweden)

    C. Gils

    2016-01-01

    Full Text Available Background. Congenital chloride diarrhea (CCD is an autosomal recessive disorder caused by mutations in the genes encoding the intestinal Cl−/HCO3- exchanger and is clinically characterized by watery, profound diarrhea, electrolyte disturbances, and metabolic alkalosis. The CCD diagnosis is based on the clinical symptoms and measurement of high chloride concentration in feces (>90 mmol/L and is confirmed by DNA testing. Untreated CCD is lethal, while long-term clinical outcome improves when treated correctly. Case Presentation. A 27-year-old woman had an emergency caesarian due to pain and discomfort in gestational week 36 + 4. The newborn boy had abdominal distension and yellow fluid per rectum. Therapy with intravenous glucose and sodium chloride decreased his stool frequency and improved his clinical condition. A suspicion of congenital chloride diarrhea was strongly supported using blood gas analyzer to measure an increased chloride concentration in the feces; the diagnosis was confirmed by DNA testing. Discussion. Measurement of chloride in feces using an ordinary blood gas analyzer can serve as a preliminary analysis when congenital chloride diarrhea is suspected. This measurement can be easily performed with a watery feces composition. An easy-accessible chloride measurement available will facilitate the diagnostics and support the initial treatment if CCD is suspected.

  9. Estimating the chloride transport in cement paste

    OpenAIRE

    Princigallo, A.

    2012-01-01

    A method was developed to measure the diffusion coefficient of chloride ions in cement paste based on an analytical solution to Fick’s 2nd law in a cylindrical coordinate system. This natural method yielded diffusivity results within as little as a month. Testing time was reduced by exploiting the three-dimensional inward flux in the specimen. In an attempt to determine the saturation concentration, dense portland cement pastes were exposed to a concentrated chloride solution. The method prov...

  10. The English 'sweate' (Sudor Anglicus) and Hantavirus pulmonary syndrome.

    Science.gov (United States)

    Bridson, E

    2001-01-01

    A rapidly fatal viral infectious disease appeared in England in 1485, persisted for the summer months and disappeared as winter approached. This pattern of infection re-appeared in 1508, 1517, 1528, and finally 1551. The epidemic never returned. It had no respect for wealth or rank, and predominantly attacked males between the ages of 15 and 45 years. The incubation period was frighteningly short and the outcome normally fatal. The symptoms of acute respiratory disease and copious sweating were characteristic, providing the name 'the English sweating disease'. It was never in the big league of killer epidemics, such as plague and influenza, but its pockets of instant lethality in communities gave it a special ranking of horror. The infective cause of this disease remained a total mystery until it was compared with Hantavirus pulmonary syndrome (HPS) in 1994. The strength of this theory is examined in this paper, and it is concluded that, although there is a close resemblance, HPS does not match the English sweating disease completely and positive identification of a possible rodent carrier for the latter was not established.

  11. Anthropometric profile and sweat rate in young soccer players

    Directory of Open Access Journals (Sweden)

    Luciana Rossi

    2009-04-01

    Full Text Available Soccer is a sport whose worldwide acceptance has been growing year after year, and is one of the most important events in the sports world. A growing number of children and teenagers are engaged in this activity, but studies regarding risk factors such as adiposity and negative impacts such as dehydration and hyperthermia are scarce. The aim of this study was to evaluate the anthropometric profile, sweat rate and risk of dehydration among young soccer players. For anthropometric assessment, weight, height, circumference measures and skinfold thickness were collected and used for the determination of body mass index and percent body fat of each player. For determination of the sweat rate, players were weighed before and after pre-competition training. Analysis of fat percentage (14.4 ± 3.6% and the sum of skinfolds showed that the players presented an optimal percentage and activity pattern, probably related to their role in the game. Although low (8.8 ± 6.6 mL/min, the sweat rate varied widely among players, wit the observation of a significant reduction (p<0.05 in final weight. The risk of dehydration was low, but the same cannot be stated for the risk of hyperthermia. Further studies involving this population are necessary to establish an adequate hydration strategy, with emphasis on the monitoring of signs of hyperthermia.

  12. Anthropometric profile and sweat rate in young soccer players

    Directory of Open Access Journals (Sweden)

    Vanessa Aparecida de Brito Reis

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n2p134   Soccer is a sport whose worldwide acceptance has been growing year after year, and is one of the most important events in the sports world. A growing number of children and teenagers are engaged in this activity, but studies regarding risk factors such as adiposity and negative impacts such as dehydration and hyperthermia are scarce. The aim of this study was to evaluate the anthropometric profile, sweat rate and risk of dehydration among young soccer players. For anthropometric assessment, weight, height, circumference measures and skinfold thickness were collected and used for the determination of body mass index and percent body fat of each player. For determination of the sweat rate, players were weighed before and after pre-competition training. Analysis of fat percentage (14.4 ± 3.6% and the sum of skinfolds showed that the players presented an optimal percentage and activity pattern, probably related to their role in the game. Although low (8.8 ± 6.6 mL/min, the sweat rate varied widely among players, wit the observation of a significant reduction (p < 0.05 in final weight. The risk of dehydration was low, but the same cannot be stated for the risk of hyperthermia. Further studies involving this population are necessary to establish an adequate hydration strategy, with emphasis on the monitoring of signs of hyperthermia.

  13. Metastatic apocrine sweat gland adenocarcinoma in a terrier dog.

    Science.gov (United States)

    Baharak, Akhtardanesh; Reza, Kheirandish; Shahriar, Dabiri; Omid, Azari; Daruoosh, Vosoogh; Nasrin, Askari

    2012-08-01

    This report describes the clinical and pathological aspects of an apocrine sweat gland carcinoma with distant metastasis in an aged dog. A 7-year-old male terrier dog was referred to small animal hospital of Shahid Bahonar University of Kerman with a 5.5×3.5 centimeter pedunculated mass on its head near left auricular region which had been progressively growing since three months ago. The radiography showed no local and distant metastasis. Surgical excision and histological evaluation was done. Histologically, the mass was composed of epithelial cells arranged in glandular and solid patterns. The morphologic findings suggested either a primary or metastatic apocrine-gland carcinoma. Immunohistochemically, the tumor cells were intensely positive for cytokeratin 7 and 20 and negative for S100 protein. On the basis of histopathological and clinical findings, the tumor was diagnosed as a malignant apocrine gland tumor, arising from apocrine sweat glands of the skin. Local tumor recurrence with anorexia and weight loss was reported by the owner nine month later. Severe submandibular and prescapular lymphadenomegaly was noted in clinical examination. Several large pulmonary nodules were noted in chest radiographs resembling mediastinal lymph node metastasis. Second surgery and chemotherapy was rejected by the owner due to grave prognosis of the patient. The animal was died 45 days later due to respiratory complications. Tumors of apocrine sweat glands are relatively uncommon in dogs whereas apocrine gland adenocarcinoma with distant metastasis is extremely rare.

  14. High temperature alloy chloridation at 850 C

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, S.; Bekaddour, A. [Laboratoire de Recherches sur la Reactivite des Solides, UMR 5613 CNRS, Universite de Bourgogne, 9 avenue Alain Savary, 21078 Dijon (France); Ched' Homme, S. [DTM/SRPU/LPPU, CEA Valduc, 21120 Is-sur-Tille (France); Amilain-Basset, K.; Buisson, L. [Interface Caracterisation des Materiaux, Universite de Bourgogne, 21078 Dijon (France)

    2007-05-15

    The resistance of eight alloys against chloridation was tested at 850 C in Ar/Cl{sub 2} (2.5% Cl{sub 2}) for 15 min. Pre-oxidation treatments were performed for 1 h and 8 h at 850 C in order to produce a thin, adherent and protective oxide scale able to improve the chloridation behaviour of the tested materials. The chloridised sample morphologies were compared to the morphologies observed on the non pre-oxidised samples. The alloys containing a large amount of iron did not exhibit any chloridation resistance, even after pre-oxidation, and were severely damaged. The nickel based alloys gave interesting results but were also attacked by chloride, probably by the ''active oxidation'' mechanism. The duration of the pre-oxidation treatment plays an important role, since the 8 h pre-oxidation appears more beneficial than the 1 h pre-oxidation, to delay the chloridation, probably because of the best quality of the oxide layer grown during 8 h. For the nickel based materials, the effects of chloride appear less severe than for the iron-based alloys, but are not stopped. The ''active oxidation'' mechanism is proposed to be responsible for the degradation of the tested materials. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  15. Durability of cracked fibre reinforced concrete structures exposed to chlorides

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Ekman, Tom; Hansen, Kurt Kielsgaard

    1999-01-01

    Durability studies are carried out by subjecting FRC-beams to combined mechanical and environmental load. Mechanical load is obtained by exposing beams to 4-point bending until a predefined crack width is reached, using a newly developed test setup. Exposure to a concentrated chloride solution is...... as main reinforcement. The effect of the cracks, the fibres and the concrete quality on the chloride penetration is studied....... is used as environmental load. The chloride penetration is characterized both qualitatively (UV-test) and quantitatively (chloride profile) and by microscopy. The test programme involves three different concrete qualities. Both steel fibres and polypropylene fibres are used in the concrete beams as well...

  16. Evaluation and review of body fluids saliva, sweat and tear compared to biochemical hydration assessment markers within blood and urine.

    Science.gov (United States)

    Villiger, M; Stoop, R; Vetsch, T; Hohenauer, E; Pini, M; Clarys, P; Pereira, F; Clijsen, R

    2018-01-01

    Evaluating and testing hydration status is increasingly requested by rehabilitation, sport, military and performance-related activities. Besides commonly used biochemical hydration assessment markers within blood and urine, which have their advantages and limitations in collection and evaluating hydration status, there are other potential markers present within saliva, sweat or tear. This literature review focuses on body fluids saliva, sweat and tear compared to blood and urine regarding practicality and hydration status influenced by fluid restriction and/or physical activity. The selected articles included healthy subjects, biochemical hydration assessment markers and a well-described (de)hydration procedure. The included studies (n=16) revealed that the setting and the method of collecting respectively accessing body fluids are particularly important aspects to choose the optimal hydration marker. To obtain a sample of saliva is one of the simplest ways to collect body fluids. During exercise and heat exposures, saliva composition might be an effective index but seems to be highly variable. The collection of sweat is a more extensive and time-consuming technique making it more difficult to evaluate dehydration and to make a statement about the hydration status at a particular time. The collection procedure of tear fluid is easy to access and causes very little discomfort to the subject. Tear osmolarity increases with dehydration in parallel to alterations in plasma osmolality and urine-specific gravity. But at the individual level, its sensitivity has to be further determined.

  17. Imaging calcium carbonate distribution in human sweat pore in vivo using nonlinear microscopy

    Science.gov (United States)

    Chen, Xueqin; Gasecka, Alicja; Formanek, Florian; Galey, Jean-Baptiste; Rigneault, Hervé

    2015-03-01

    Nonlinear microscopies, including two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS), were used to study individual human sweat pore morphology and topically applied antiperspirant salt penetration inside sweat pore, in vivo on human palms. Sweat pore inner morphology in vivo was imaged up to the depth of 100 μm by TPEF microscopy. The 3D penetration and distribution of "in situ calcium carbonate" (isCC), an antiperspirant salt model, was investigated using CARS microscopy.

  18. The effect of heat acclimation on sweat microminerals: artifact of surface contamination.

    Science.gov (United States)

    Ely, Matthew R; Kenefick, Robert W; Cheuvront, Samuel N; Chinevere, Troy; Lacher, Craig P; Lukaski, Henry C; Montain, Scott J

    2013-10-01

    Heat acclimation (HA) reportedly conveys conservation in sweat micromineral concentrations when sampled from arm sweat, but time course is unknown. The observation that comprehensive cleaning of the skin surface negates sweat micromineral reductions during prolonged sweating raises the question of whether the reported HA effect is real or artifact of surface contamination. To measure sweat mineral concentrations serially during HA and determine if surface contamination plays a role in the reported mineral reductions. Calcium (Ca), copper (Cu), magnesium (Mg), and zinc (Zn) were measured in sweat obtained from 17 male volunteers using an arm bag on Day 1, 5, and 10 of a HA protocol. To study the role of contamination, sweat was simultaneously (n = 10 subjects) sampled twice daily from a cleaned site (WASH) and unclean site (NO WASH) on the scapular surface. Sweat Ca, Cu, and Mg from Arm Bag trended progressively downward from Day 1 to Day 10 of HA (p = .10-0.25). Micromineral concentrations from the WASH site did not change between Day 1, 5, or 10 (Ca = 0.30 ± 0.12 mmol/L, Cu 0.41 ± 0.53 μmol/L; Zn 1.11 ± 0.80 μmol/L). Surface contamination can confound sweat mineral estimates, as sweat Ca and Cu from NO WASH site were initially higher than WASH (p Heat acclimation does not confer reductions in sweat Ca, Cu, Mg, or Zn. When the skin surface is not cleaned, mineral residue inflates initial sweat mineral concentrations. Earlier reports of micromineral reductions during HA may have been confounded by interday cleaning variability.

  19. [Study on sweat gland regeneration induced by microenvironment of three-dimensional bioprinting].

    Science.gov (United States)

    Yao, B; Xie, J F; Huang, S; Fu, X B

    2017-01-20

    Sweat glands are abundant in the body surface and essential for thermoregulation. Sweat glands fail to conduct self-repair in patients with large area of burn and trauma, and the body temperature of patients increases in hot climate, which may cause shock or even death. Now, co-culture system, reprogramming, and tissue engineering have made progresses in inducing sweat gland regeneration, but the inductive efficiency and duration need to be improved. Cellular microenvironment can regulate cell biological behavior, including cell migration and cell differentiation. This article reviews the studies of establishment of microenvironment in vitro by three-dimensional bioprinting technology to induce sweat gland regeneration.

  20. Multidimensional Raman spectroscopic signature of sweat and its potential application to forensic body fluid identification.

    Science.gov (United States)

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-03-09

    This proof-of-concept study demonstrated the potential of Raman microspectroscopy for nondestructive identification of traces of sweat for forensic purposes. Advanced statistical analysis of Raman spectra revealed that dry sweat was intrinsically heterogeneous, and its biochemical composition varies significantly with the donor. As a result, no single Raman spectrum could adequately represent sweat traces. Instead, a multidimensional spectroscopic signature of sweat was built that allowed for the presentation of any single experimental spectrum as a linear combination of two fluorescent backgrounds and three Raman spectral components dominated by the contribution from lactate, lactic acid, urea and single amino acids. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Characterization of sweat induced with pilocarpine, physical exercise, and collected passively by metabolomic analysis.

    Science.gov (United States)

    Souza, S L; Graça, G; Oliva, A

    2017-11-12

    The elimination of the pain associated with needle picking is a strong motivation for the development of clinical non-invasive diagnostic methods. Sweat has been described as an alternative biological sample that may have a direct relation to the plasma composition. In this study, analysis of sweat of human volunteers obtained by induction with pilocarpine is compared with sweat samples obtained by physical exercise and by passive collection along 7 hours. The sweat samples have been analyzed by 1H nuclear magnetic resonance spectroscopy. A range of 34 different metabolites has been detected in sweat samples, including lactate, several amino acids, pyroglutamate, and urocanate. Most of the metabolites identified were quantified. The majority of the amino acids detected in sweat seem to have origin in the epidermis surface. No significant differences in sweat samples from female and male were observed by 1H NMR metabolomic analysis. Principal component analysis (PCA) shows that both physical exercise and pilocarpine methods seem to be equally reproducible methods in terms of sweat metabolite composition presenting better repeatability than natural sweat collection. Nevertheless, this difference is mainly originated from amino acids with origin from the skin surface. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Composition of sweat of the horse during prolonged epinephrine (adrenaline) infusion, heat exposure, and exercise.

    Science.gov (United States)

    Kerr, M G; Snow, D H

    1983-08-01

    Temporal changes in sweat composition were studied in 4 horses during epinephrine (adrenaline) infusion (0.13 to 0.31 micrograms/kg/min for 3 hours), heat exposure (41 C, [33 C wet bulb] for 5 to 6 hours), and exercise (16 to 18 km/hr for 58 to 80 km). Four ponies also were studied during heat exposure. Sweat produced by each of the stimuli was hypertonic for Na+, K+, and Cl-. These electrolyte concentrations remained constant during the central period of the experiments, with changes occurring near the beginning and toward the end. The Na+ was significantly higher and K+ significantly lower in epinephrine-induced sweat than in heat-induced sweat, and the pattern of change in sweat Na/K ratio varied among the 3 stimuli. The Ca2+ concentration decreased with time and was hypotonic after 15 minutes of epinephrine-induced sweating. Concentrations of Mg2+ and protein decreased exponentially with time. There was a high correlation between them, although the Mg2+ was not protein-bound. Sweat urea concentration was directly related to plasma urea concentration. When plasma glucose concentration became greater than 10 to 12 mmole/L during epinephrine infusion, glucose appeared in the sweat and its concentration rose to 8 to 12 mmole/L of sweat when plasma glucose was more than 20 mmole/L.

  3. In vivo sweat film layer thickness measured with Fourier-domain optical coherence tomography

    CSIR Research Space (South Africa)

    Jonathan, E

    2008-01-01

    Full Text Available the added advantage of supporting near-real time or video rate imaging speed. Consequently, FD-OCT supports assessment of tissue structure as well as near-real time imaging of functioning small organs in tissue [16–19]. The focus of this paper is direct... accurate measurement of SFL thickness as a diagnostic parameter of sweat intensity while near-real time imaging of the responsible small organs, namely sweat glands, sweat ducts and sweat pores is also of interest. 2. Experimental 2.1. Apparatus OCT...

  4. Evaporimeter and Bubble-Imaging Measures of Sweat Gland Secretion Rates.

    Directory of Open Access Journals (Sweden)

    Jeeyeon Kim

    Full Text Available Beta-adrenergically-stimulated sweat rates determined by evaporimetry or by sweat bubble imaging are useful for measuring CFTR function because they provide a near-linear readout across almost the full range of CFTR function. They differentiate cystic fibrosis (CF subjects from CF carriers and carriers from controls. However, evaporimetry, unlike bubble imaging, appears to be unable to detect improved levels of CFTR function in G551D subjects taking the CFTR modulator ivacaftor. Here, we quantify the sensitivity of evaporimetry and bubble imaging methods for assessing low levels of CFTR-dependent sweat rates. To establish sensitivity, we did dose-ranging studies using intradermally injected [cAMP]i-elevating cocktails. We reduced isoproterenol/aminophylline levels while maintaining a high level of atropine to block muscarinic elevation of [Ca2+]i. We stimulated the same sets of glands for both assays and recorded responses for 20 min. In response to a 3-log dilution of the stimulating cocktail (0.1%, bubble responses were detected in 12/12 tests (100%, with 49% ± 3% of glands secreting to produce an aggregate volume of 598 nl across the 12, 20-min tests. This was ~5% of the response to full cocktail. Evaporimetry detected responses in 3/12 (25% tests with an aggregate secretion volume of 175 nl. After stimulation with a still more dilute cocktail (0.03%, bubble imaging detected 15 ± 13% of glands secreting at a rate ~0.9% of the response to full cocktail, while zero responding was seen with evaporimetry. The bubble imaging method detected secretion down to aggregate rates of <0.2 nl/(cm2·min, or ~1/30th of the average basal transepithelial water loss (TEWL in the test subject of 4 g/m2·hr or 6.7 nl/(cm2·min. The increased sensitivity of bubble imaging may be required to detect small but physiologically important increases in secretion rates produced by CFTR modulators.

  5. Determination of the maximum rate of eccrine sweat glands’ ion reabsorption using the galvanic skin conductance to local sweat rate relationship.

    Science.gov (United States)

    Amano, Tatsuro; Gerrett, Nicola; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Havenith, George; Kondo, Narihiko

    2016-02-01

    The purpose of the present study was to develop and describe a simple method to evaluate the rate of ion reabsorption of eccrine sweat glands in human using the measurement of galvanic skin conductance (GSC) and local sweating rate (SR). This purpose was investigated by comparing the SR threshold for increasing GSC with following two criteria of sweat ion reabsorption in earlier studies such as (1) the SR threshold for increasing sweat ion was at approximately 0.2–0.5 mg/cm2/min and (2) exercise heat acclimation improved the sweat ion reabsorption ability and would increase the criteria 1. Seven healthy non-heat-acclimated male subjects received passive heat treatment both before and after 7 days of cycling in hot conditions (50% maximum oxygen uptake, 60 min/day, ambient temperature 32 °C, and 50% relative humidity). Subjects became partially heat-acclimated, as evidenced by the decreased end-exercise heart rate (p rate of perceived exhaustion (p maximum rate of sweat ion reabsorption of eccrine sweat glands in humans.

  6. Assessment of the in vivo genotoxicity of cadmium chloride, chloroform, and D,L-menthol as coded test chemicals using the alkaline comet assay.

    Science.gov (United States)

    Wada, Kunio; Fukuyama, Tomoki; Nakashima, Nobuaki; Matsumoto, Kyomu

    2015-07-01

    As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM) international validation study of in vivo rat alkaline comet assays, we examined cadmium chloride, chloroform, and D,L-menthol under blind conditions as coded chemicals in the liver and stomach of Sprague-Dawley rats after 3 days of administration. Cadmium chloride showed equivocal responses in the liver and stomach, supporting previous reports of its poor mutagenic potential and non-carcinogenic effects in these organs. Treatment with chloroform, which is a non-genotoxic carcinogen, did not induce DNA damage in the liver or stomach. Some histopathological changes, such as necrosis and degeneration, were observed in the liver; however, they did not affect the comet assay results. D,L-Menthol, a non-genotoxic non-carcinogen, did not induce liver or stomach DNA damage. These results indicate that the comet assay can reflect genotoxic properties under blind conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Comparison of three methods for estimation of exercise-related ion losses in sweat of horses.

    Science.gov (United States)

    Kingston, J K; McCutcheon, L J; Geor, R J

    1999-10-01

    To quantify total fluid loss in sweat of Thoroughbreds during >3 hours of low-intensity exercise in controlled conditions and to calculate and compare estimated ion losses in sweat, according to 3 methods. 6 exercise-trained Thoroughbreds. Fluid and ion losses in sweat were measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km. Horses were given a 15-minute rest period at the end of three 15-km exercise phases. Horses completed 2 exercise trials. Ion losses in sweat were calculated, using measurements of local sweating rate and sweat ion composition (SWT), change in net exchangeable cation content (CAT), and change in extracellular ion content (PLAS) derived from plasma total solids and ion concentrations. Measurement of SWT revealed a mean (+/- SEM) fluid loss in sweat during 45 km of exercise of 27.5 +/- 1.6 L. Total ion loss in sweat was approximately 241 g or 7.8 mol with higher sodium losses in the second and third phases of exercise compared with the first phase. Losses of sodium and potassium calculated by SWT or CAT were not significantly different from each other, whereas losses of these ions as determined by PLAS were significantly lower. Calculation of ion losses from a mean whole body sweating rate extrapolated from either local sweating rate and sweat ion composition or from change in net exchangeable cation content provide similar results, whereas ion losses determined by changes in extracellular ion content derived from plasma total solids and ion concentration results in underestimation of actual losses.

  8. The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise-heat stress.

    Science.gov (United States)

    Hayden, Gavin; Milne, Helen C; Patterson, Mark J; Nimmo, Myra A

    2004-05-01

    Seven active male subjects cycled for 60 min at 29.5 (0.8)% peak work rate on three separate occasions in a hot environmental condition [36.0 (0.1) degrees C, 60 (1)% relative humidity] in order to determine the reproducibility of a closed-pouch sweat collection technique for sweat composition at the scapula, forearm and thigh. To confirm that sweat composition was not influenced by between-trial variations in sudomotor drive, local sweat rate, whole-body sweat rate, heart rate (HR), rectal temperature (T(re)) and mean skin temperature (T(sk)) responses were also measured, consequently reproducibility was also established for these variables. Sweat composition did not differ among trials, with the mean coefficients of variation (CVs) for sweat [Na(+)], [K(+)] and pH being 10.4 (7.4)%, 8.1 (6.5)% and 1.3 (1.1)%, respectively. Local sweat rates did not differ among the three trials (P>0.05) although whole-body sweat rate was reduced in the third trial (Psweat rates, respectively. Between-trial differences were not evident for T(re), T(sk) or HR with mean CVs of 0.3 (0.2)%, 0.7 (0.6)% and 3.9 (1.7)%, respectively, although HR tended to be greater in the first trial ( P=0.08). It is proposed that moderate variations in sweat composition were influenced by variations in the local sweat rate, which were induced by application of the pouch.

  9. Metastatic apocrine sweat gland adenocarcinoma in a terrier dog

    OpenAIRE

    Baharak, Akhtardanesh; Reza, Kheirandish; Shahriar, Dabiri; Omid, Azari; Daruoosh, Vosoogh; Nasrin, Askari

    2012-01-01

    This report describes the clinical and pathological aspects of an apocrine sweat gland carcinoma with distant metastasis in an aged dog. A 7-year-old male terrier dog was referred to small animal hospital of Shahid Bahonar University of Kerman with a 5.5×3.5 centimeter pedunculated mass on its head near left auricular region which had been progressively growing since three months ago. The radiography showed no local and distant metastasis. Surgical excision and histological evaluation was don...

  10. Sex differences in amino acids lost via sweating could lead to differential susceptibilities to disturbances in nitrogen balance and collagen turnover

    OpenAIRE

    Dunstan, R. H.; Sparkes, D. L.; Dascombe, B. J.; Stevens, C. J.; Murphy, G. R.; Macdonald, M. M.; Gottfries, J.; Gottfries, C.-G.; Roberts, T. K.

    2017-01-01

    Fluid collected during sweating is enriched with amino acids derived from the skin?s natural moisturising factors and has been termed ?faux? sweat. Little is known about sex differences in sweat amino acid composition or whether faux sweat amino acid losses affect nitrogen balance. Faux sweat collected by healthy adults (n?=?47) after exercise, and at rest by chronic fatigue patients, was analysed for amino acid composition. Healthy females had higher total amino acid concentrations in sweat ...

  11. A device to improve the Schleger and Turner method for sweating rate measurements

    Science.gov (United States)

    Pereira, Alfredo Manuel Franco; Alves, Alexandre; Infante, Paulo; Titto, Evaldo A. L.; Baccari, Flávio; Almeida, J. A. Afonso

    2010-01-01

    The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.

  12. NKCC1 and NHE1 are abundantly expressed in the basolateral plasma membrane of secretory coil cells in rat, mouse, and human sweat glands

    DEFF Research Database (Denmark)

    Nejsum, Lene Niemann; Prætorius, Jeppe; Nielsen, Søren

    2005-01-01

    1 (NHE1) protein has been localized to both the duct and secretory coil of human sweat duct; however, the NHE1 abundance in the duct was not compared with that in the secretory coil. The aim of this study was to test whether mRNA encoding NKCC1, NKCC2, and Na(+)-coupled acid-base transporters...... and the corresponding proteins are expressed in rodent sweat glands and, if expressed, to determine the cellular and subcellular localization in rat, mouse, and human eccrine sweat glands. NKCC1 mRNA was demonstrated in rat palmar tissue, including sweat glands, using RT-PCR, whereas NKCC2 mRNA was absent. Also, NHE1 m...... palmar skin by immunoblotting, whereas NKCC2, NHE2, and NHE3 proteins were not detected. Immunohistochemistry was performed using sections from rat, mouse, and human palmar tissue. Immunoperoxidase labeling revealed abundant expression of NKCC1 and NHE1 in the basolateral domain of secretory coils of rat...

  13. Exercise- and methylcholine-induced sweating responses in older and younger men: effect of heat acclimation and aerobic fitness

    Science.gov (United States)

    Inoue, Y.; Havenith, George; Kenney, W. Larry; Loomis, Joseph L.; Buskirk, Elsworth R.

    The purpose of this investigation was to examine the effects of aging and aerobic fitness on exercise- and methylcholine-induced sweating responses during heat acclimation. Five younger [Y group - age: 23+/-1 (SEM) years; maximal oxygen consumption (V.O2max): 47+/-3 ml.kg-1.min-1], four highly fit older (HO group - 63+/-3 years; 48+/-4 ml.kg-1.min-1) and five normally fit older men (NO group - 67+/-3 years; 30+/-1 ml.kg-1.min-1) who were matched for height, body mass and percentage fat, were heat acclimated by daily cycle exercise ( 35% V.O2max for 90 min) in a hot (43°C, 30% RH) environment for 8 days. The heat acclimation regimen increased performance time, lowered final rectal temperature (Tre) and percentage maximal heart rate (%HRmax), improved thermal comfort and decreased sweat sodium concentration similarly in all groups. Although total body sweating rates (M.sw) during acclimation were significantly greater in the Y and HO groups than in the NO group (Pgroup), the M.sw did not change in all groups with the acclimation sessions. Neither were local sweating rates (m.sw) on chest, back, forearm and thigh changed in all groups by the acclimation. The HO group presented greater forearm m.sw (30-90 min) values and the Y group had greater back and thigh m.sw (early in exercise) values, compared to the other groups (PHO>NO, and on the forearm Y=HO>NO. No group differences were observed for activated sweat gland density at any site. The SGO at the respective sites increased in the post-acclimation test regardless of group (Pgroups than in the Y group. These findings suggest that heat tolerance and the improvement with acclimation are little impaired not only in highly fit older but also normally fit older men, when the subjects exercised at the same relative exercise intensity. Furthermore, the changes induced by acclimation appear associated with an age-related decrease in V.O2max. However methylcholine-activated SGO and the magnitude of improvement of SGO with

  14. On-ice sweat rate, voluntary fluid intake, and sodium balance during practice in male junior ice hockey players drinking water or a carbohydrate-electrolyte solution.

    Science.gov (United States)

    Palmer, Matthew S; Logan, Heather M; Spriet, Lawrence L

    2010-06-01

    This study evaluated the repeatability of hydration and sweat measurements taken during on-ice hockey practices with players drinking only water, and determined whether having only a carbohydrate-electrolyte solution (CES) to drink during practices decreased fluid intake or affected other hydration and (or) sweat measures. All testing was conducted on elite players of an Ontario Hockey League team (+/-SE; mean age, 17.6 +/- 0.3 years; mean height, 182.9 +/- 1.4 cm; mean body mass, 83.0 +/- 1.7 kg). Players were studied 3 times over the course of 6 weekly on-ice practices (+/-SE; mean playing time, 1.58 +/- 0.07 h; mean temperature, 11.4 +/- 0.8 degrees C; mean relative humidity, 52% +/- 3%). There was strong repeatability of the measured hydration and sweat parameters between 2 similar on-ice practices when players drank only water. Limiting the players to drinking only a CES (as opposed to water) did not decrease fluid intake during practice (+/-SE; mean CES intake, 0.72 +/- 0.07 L.h-1 vs. mean water intake, 0.82 +/- 0.08 L.h-1) or affect sweat rate (1.5 +/- 0.1 L.h-1 vs. 1.5 +/- 0.1 L.h-1), sweat sodium concentration (72.4 +/- 5.6 mmol.L-1 vs. 73.0 +/- 4.4 mmol.L-1), or percent body mass loss (1.1% +/- 0.2% vs. 0.9% +/- 0.2%). Drinking a CES also improved sodium balance (-2.1 +/- 0.2 g.h-1 vs. -2.6 +/- 0.3 g.h-1) and provided the players with a significant carbohydrate (43 +/- 4 g.h-1 vs. 0 +/- 0 g.h-1) during practice. In summary, a single field sweat test during similar on-ice hockey practices in male junior hockey players is sufficient to evaluate fluid and electrolyte balance. Also, a CES does not affect voluntary fluid intake during practice, compared with water, in these players. The CES provided some salt to offset the salt lost in sweat, and carbohydrate, which may help maintain physical and mental performance in the later stages of practice.

  15. Congenital Chloride Diarrhea: Diagnosis by Easy-Accessible Chloride Measurement in Feces

    OpenAIRE

    van Gils, C.; M.-C. Eckhardt; Nielsen, P E; Nybo, M.

    2016-01-01

    Background. Congenital chloride diarrhea (CCD) is an autosomal recessive disorder caused by mutations in the genes encoding the intestinal Cl?/HCO3 ? exchanger and is clinically characterized by watery, profound diarrhea, electrolyte disturbances, and metabolic alkalosis. The CCD diagnosis is based on the clinical symptoms and measurement of high chloride concentration in feces (>90?mmol/L) and is confirmed by DNA testing. Untreated CCD is lethal, while long-term clinical outcome improves whe...

  16. Sweat : Materiality and Fluidity of Perspiration in in Eighteenth-Century Medicine

    NARCIS (Netherlands)

    Verwaal, Ruben

    2015-01-01

    How can a bodily excretion like sweat, often accompanied with a stench or associated with anxiety and distress, enrich our view of the history of science? This paper argues that following the fluid and flow of sweat has in fact particular advantages, because it provides a unique perspective by

  17. Lactate and ammonia concentration in blood and sweat during incremental cycle ergometer exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Mook, GA; Gips, CH; Verkerke, GJ

    It is known that the concentrations of ammonia and lactate in blood increase during incremental exercise. Sweat also contains lactate and ammonia. The aim of the present study was to investigate the physiological response of lactate and ammonia in plasma and sweat during a stepwise incremental cycle

  18. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications

    Science.gov (United States)

    Sonner, Z.; Wilder, E.; Heikenfeld, J.; Kasting, G.; Beyette, F.; Swaile, D.; Sherman, F.; Joyce, J.; Hagen, J.; Kelley-Loughnane, N.; Naik, R.

    2015-01-01

    Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat. PMID:26045728

  19. A Simple and Valid Method to Determine Thermoregulatory Sweating Threshold and Sensitivity

    Science.gov (United States)

    2009-01-01

    therefore, preferred for sweating threshold temperature and sensitivity analysis (32). Volunteers spit into a cup during data collection to avoid spurious...MA, Stephenson LA. Control of sweating during the human menstrual cycle. Eur J Appl Physiol 58: 890–895, 1989. 21. Kondo N, Shibasaki M, Aoki K, Koga

  20. Immunological multimetal deposition for rapid visualization of sweat fingerprints.

    Science.gov (United States)

    He, Yayun; Xu, Linru; Zhu, Yu; Wei, Qianhui; Zhang, Meiqin; Su, Bin

    2014-11-10

    A simple method termed immunological multimetal deposition (iMMD) was developed for rapid visualization of sweat fingerprints with bare eyes, by combining the conventional MMD with the immunoassay technique. In this approach, antibody-conjugated gold nanoparticles (AuNPs) were used to specifically interact with the corresponding antigens in the fingerprint residue. The AuNPs serve as the nucleation sites for autometallographic deposition of silver particles from the silver staining solution, generating a dark ridge pattern for visual detection. Using fingerprints inked with human immunoglobulin G (hIgG), we obtained the optimal formulation of iMMD, which was then successfully applied to visualize sweat fingerprints through the detection of two secreted polypeptides, epidermal growth factor and lysozyme. In comparison with the conventional MMD, iMMD is faster and can provide additional information than just identification. Moreover, iMMD is facile and does not need expensive instruments. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Corrosion behavior of nickel-containing alloys in artificial sweat.

    Science.gov (United States)

    Randin, J P

    1988-07-01

    The corrosion resistance of various nickel-containing alloys was measured in artificial sweat (perspiration) using the Tafel extrapolation method. It was found that Ni, CuNi 25 (coin alloy), NiAl (colored intermetallic compounds), WC + Ni (hard metal), white gold (jewelry alloy), FN42 and Nilo Alby K (controlled expansion alloys), and NiP (electroless nickel coating) are in an active state and dissolve readily in oxygenated artificial sweat. By contrast, austenitic stainless steels, TiC + Mo2C + Ni (hard metal), NiTi (shape-memory alloy), Hastelloy X (superalloy), Phydur (precipitation hardening alloy), PdNi and SnNi (nickel-containing coatings) are in a passive state but may pit under certain conditions. Cobalt, Cr, Ti, and some of their alloys were also investigated for the purpose of comparison. Cobalt and its alloys have poor corrosion resistance except for Stellite 20. Chromium and high-chromium ferritic stainless steels have a high pitting potential but the latter are susceptible to crevice corrosion. Ti has a pitting potential greater than 3 V. Comparison between the in vitro measurements of the corrosion rate of nickel-based alloys and the clinical observation of the occurrence of contact dermatitis is discussed.

  2. Proteomic and peptidomic analysis of human sweat with emphasis on proteolysis.

    Science.gov (United States)

    Yu, Yijing; Prassas, Ioannis; Muytjens, Carla M J; Diamandis, Eleftherios P

    2017-02-23

    Sweat is produced by eccrine and apocrine glands and represents a biological fluid with established roles in thermo-regulation and host infection defense. The composition of sweat is highly dynamic and alters significantly in various skin and other disorders. Therefore, in-depth profiling of sweat protein composition is expected to augment our understanding of the pathobiology of several skin diseases and may lead to the identification of useful sweat-based disease biomarkers. We here reported an in-depth analysis of the human sweat proteome and peptidome. Sweat was collected from healthy males and healthy females of ages 20-60years, following strenuous exercise. Two sweat pools were prepared (1 for males and 1 for females) and were subjected to sample preparation for mass spectrometric analysis. We identified a total of 861 unique proteins during our proteomic analysis and 32,818 endogenous peptides (corresponding to additional 1067 proteins) from our peptidomics workflow. As expected, the human skin was identified as the most abundant source of sweat proteins and peptides. Several skin proteases and protease inhibitors were identified in human sweat, highlighting the intense proteolytic activity of human skin. The presence of several antimicrobial peptides supports the functional roles of sweat in host defense and innate immunity. Sweat is a skin-associated biological fluid, secreted by eccrine and apocrine glands, with essential function in body thermo-regulation and host infection defense. In the present study, we performed in-depth profiling of both sweat proteome and peptidome composition. Our data provide the most in-depth characterization of the skin's catalytic network present in sweat. For the first time, we brought to light novel peptides in human sweat that potentially have antimicrobial activity, which highlight the important role of this fluid in innate immunity. All these findings allow us to have a better understanding of the complex web of

  3. Moxifloxacinium chloride monohydrate

    Directory of Open Access Journals (Sweden)

    Su-Xiang Wu

    2011-10-01

    Full Text Available The title compound {systematic name: 7-[(1S,6S-8-aza-2-azoniabicyclo[4.3.0]non-8-yl]-1-cyclopropyl-6-fluoro-8-methoxy-4-oxo-1,4-dihydroquinoline-3-carboxylic acid chloride monohydrate}, C21H25FN3O4+·Cl−·H2O, crystallizes with two moxifloxacinium cations, two chloride ions and two uncoordinated water molecules in the unit cell. The crystal structure has a pseudo-inversion center except for the chloride ions. In both moxifloxacinium cations, the quinoline rings are approximately planar, the maximum atomic deviations being 0.107 (3 and 0.118 (3 Å. The piperidine rings adopt a chair conformation while the pyrrolidine rings display a half-chair conformation. In the crystal, the carboxyl groups, the protonated piperidyl groups, the uncoordinated water molecule and chloride anions participate in O—H...O, O—H...Cl and N—H...Cl hydrogen bonding; weak intermolecular C—H...O and C—H...Cl hydrogen bonding is also present in the crystal structure.

  4. Strontium-89 Chloride

    Science.gov (United States)

    ... may harm the fetus.notify any health care professional (especially other doctors) giving you treatment that you will be taking strontium-89 chloride.do not have any vaccinations (e.g., measles or flu shots) without talking to your doctor.

  5. Repassivation Potential of Alloy 22 in Sodium and Calcium Chloride Brines

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; Ilevbare, G O; Carranza, R M

    2007-08-11

    A comprehensive matrix of 60 tests was designed to explore the effect of calcium chloride vs. sodium chloride and the ratio R of nitrate concentration over chloride concentration on the repassivation potential of Alloy 22. Tests were conducted using the cyclic potentiodynamic polarization (CPP) technique at 75 C and at 90 C. Results show that at a ratio R of 0.18 and higher nitrate was able to inhibit the crevice corrosion in Alloy 22 induced by chloride. Current results fail to show in a consistent way a different effect on the repassivation potential of Alloy 22 for calcium chloride solutions than for sodium chloride solutions.

  6. Sweat-inducing physiological challenges do not result in acute changes in hair cortisol concentrations.

    Science.gov (United States)

    Grass, Juliane; Kirschbaum, Clemens; Miller, Robert; Gao, Wei; Steudte-Schmiedgen, Susann; Stalder, Tobias

    2015-03-01

    Hair cortisol concentrations (HCC) are assumed to provide a stable, integrative marker of long-term systemic cortisol secretion. However, contrary to this assumption, some recent observations have raised the possibility that HCC may be subject to acute influences, potentially related to cortisol incorporation from sweat. Here, we provide a first detailed in vivo investigation of this possibility comprising two independent experimental studies: study I (N=42) used a treadmill challenge to induce sweating together with systemic cortisol reactivity while in study II (N=52) a sauna bathing challenge induced sweating without systemic cortisol changes. In both studies, repeated assessments of HCC, salivary cortisol, cortisol in sweat and individuals' sweating rate (single assessment) were conducted on the experimental day and at a next-day follow-up. Results across the two studies consistently revealed that HCC were not altered by the acute interventions. Further, HCC were found to be unrelated to acute salivary cortisol reactivity, sweat cortisol levels, sweating rate or the time of examination. In line with previous data, cortisol levels in sweat were strongly related to total salivary cortisol output across the examined periods. The present results oppose recent case report data by showing that single sweat-inducing interventions do not result in acute changes in HCC. Our data also tentatively speak against the notion that cortisol in sweat may be a dominant source of HCC. Further, our findings also indicate that HCC are not subject to diurnal variation. This research provides further support for hair cortisol analysis as a marker of integrated long-term systemic cortisol secretion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Congenital chloride diarrhea: late presentation

    OpenAIRE

    Al Bishi, Laila; Mustafa,

    2011-01-01

    Laila Al Bishi1, Mustafa Al Toonisi2Pediatric Department, North West Armed Forces Hospital, Tabuk, Kingdom of Saudi ArabiaAbstract: We report the case of a male infant who presented with diarrhea at 6 months of age. He was failing to thrive, and biochemical investigation revealed hypokalemic hypochloremic metabolic alkalosis. Diagnosis of congenital chloride diarrhea was suspected and confirmed by the stool chloride result. He was started on high-dose sodium chloride and potassium chloride to...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... diagnostic evaluation should include a newborn screening, a sweat chloride test, a genetic or carrier test, and ... vs. IRT-DNA States Newborn Screening for CF Sweat Test Life With CF X close Caring for ...

  9. Concrete with Improved Chloride Binding and Chloride Resistivity by Blended Cements

    Directory of Open Access Journals (Sweden)

    Katalin Kopecskó

    2017-01-01

    Full Text Available Durability and service life of concrete structures can be endangered by chloride ions. Two phenomena help to keep control of chloride effects. On one hand cements are able to bind chloride ions by their aluminate clinker phases or by the clinker substituting materials. On the other hand resistivity of concrete against chloride penetration can be improved by careful selection of concrete constituents and production. Detailed results of two series of extensive experimental studies are presented herein. Chloride ion binding capacity of tested cements in decreasing sequence was the following: (1 CEM III/B 32,5 N-S; (2 CEM III/A 32,5 N; (3 CEM II/B 32,5 R; (4 CEM II/B-M (V-L 32,5 R; (5 CEM I 42,5 N. Test results indicated that the increasing substitution of clinkers by GGBS improves the chloride resistivity in concrete made with the same water to cement ratio. The application of air entraining agent increases considerably the values of Dnssm. Based on the migration coefficients (Dnssm the following sequence of efficiency was found (from the best: CEM III/B 32,5 N > CEM V/A (S-V 32,5 N > CEM III/A 32,5 N > CEM II/B-S 42,5 R > CEM II/A-S 42,5 N > CEM I 42,5 N.

  10. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat.

    Science.gov (United States)

    Meyer, F; Laitano, O; Bar-Or, O; McDougall, D; Heigenhauser, G J F; Heingenhauser, G J F

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42 degrees C, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 +/- 1.2 and 21.2 +/- 1.7 mM; P sweat from women and men (18.2 +/- 1.9 and 14.8 +/- 1.6 mM, respectively), but Lac- was weakly associated with SR (P > 0.05; r = -0.27). Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 +/- 0.4 mM). Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 +/- 0.4, boys = 4.6 +/- 0.6, women = 2.7 +/- 0.2, and men = 3.0 +/- 0.2 mM; P sweat pH was lower than that of adults (mean +/- SEM, girls = 5.4 +/- 0.2, boys = 5.0 +/- 0.1, women = 6.2 +/- 0.5, and men = 6.2 +/- 0.4 for bout 1, and girls = 5.4 +/- 0.2, boys = 6.5 +/- 0.5, women = 5.2 +/- 0.2, and men = 6.9 +/- 0.4 for bout 2). This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56). Blood pH increased from rest (mean +/- SEM; 7.3 +/- 0.02) to the end of exercise (7.4 +/- 0.01) without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  11. Comfort, measured by means of a sweating manikin (Walter (TM)), of clothing containing different fibre combinations : A preliminary investigation

    CSIR Research Space (South Africa)

    Botha, Anton F

    2016-11-01

    Full Text Available and thickness, wool fabrics were better thermal insulators than the fabrics composed of the other fibres which they tested, whereas, Baxter and Cassie (1943) showed that, for a range of fabrics differing widely in fibre composition and ING MANIKIN (SOURCE... on the sweating fabric manikin WalterTM. REFERENCES ANON, N.D. Walter-Perspiring fabric manikin measurement system Version 3.0: User licence and manual. Polymer Technology & Consulting Company Ltd. BAXTER, S. & CASSIE, A.B.D. 1943. Thermal insulation...

  12. Analysis of plasticizers in poly(vinyl chloride) medical devices for infusion and artificial nutrition: comparison and optimization of the extraction procedures, a pre-migration test step.

    Science.gov (United States)

    Bernard, Lise; Cueff, Régis; Bourdeaux, Daniel; Breysse, Colette; Sautou, Valérie

    2015-02-01

    Medical devices (MDs) for infusion and enteral and parenteral nutrition are essentially made of plasticized polyvinyl chloride (PVC). The first step in assessing patient exposure to these plasticizers, as well as ensuring that the MDs are free from di(2-ethylhexyl) phthalate (DEHP), consists of identifying and quantifying the plasticizers present and, consequently, determining which ones are likely to migrate into the patient's body. We compared three different extraction methods using 0.1 g of plasticized PVC: Soxhlet extraction in diethyl ether and ethyl acetate, polymer dissolution, and room temperature extraction in different solvents. It was found that simple room temperature chloroform extraction under optimized conditions (30 min, 50 mL) gave the best separation of plasticizers from the PVC matrix, with extraction yields ranging from 92 to 100% for all plasticizers. This result was confirmed by supplemented Fourier transform infrared spectroscopy-attenuated total reflection (FTIR-ATR) and gravimetric analyses. The technique was used on eight marketed medical devices and showed that they contained different amounts of plasticizers, ranging from 25 to 36% of the PVC weight. These yields, associated with the individual physicochemical properties of each plasticizer, highlight the need for further migration studies.

  13. Eccrine Sweat Contains IL-1α, IL-1β and IL-31 and Activates Epidermal Keratinocytes as a Danger Signal

    Science.gov (United States)

    Dai, Xiuju; Okazaki, Hidenori; Hanakawa, Yasushi; Murakami, Masamoto; Tohyama, Mikiko; Shirakata, Yuji; Sayama, Koji

    2013-01-01

    Eccrine sweat is secreted onto the skin's surface and is not harmful to normal skin, but can exacerbate eczematous lesions in atopic dermatitis. Although eccrine sweat contains a number of minerals, proteins, and proteolytic enzymes, how it causes skin inflammation is not clear. We hypothesized that it stimulates keratinocytes directly, as a danger signal. Eccrine sweat was collected from the arms of healthy volunteers after exercise, and levels of proinflammatory cytokines in the sweat were quantified by ELISA. We detected the presence of IL-1α, IL-1β, and high levels of IL-31 in sweat samples. To investigate whether sweat activates keratinocytes, normal human keratinocytes were stimulated with concentrated sweat. Western blot analysis demonstrated the activation of NF-κB, ERK, and JNK signaling in sweat-stimulated keratinocytes. Real-time PCR using total RNA and ELISA analysis of supernatants showed the upregulation of IL-8 and IL-1β by sweat. Furthermore, pretreatment with IL-1R antagonist blocked sweat-stimulated cytokine production and signal activation, indicating that bioactive IL-1 is a major factor in the activation of keratinocytes by sweat. Moreover, IL-31 seems to be another sweat stimulator that activates keratinocytes to produce inflammatory cytokine, CCL2. Sweat is secreted onto the skin's surface and does not come into contact with keratinocytes in normal skin. However, in skin with a defective cutaneous barrier, such as atopic dermatitis-affected skin, sweat cytokines can directly act on epidermal keratinocytes, resulting in their activation. In conclusion, eccrine sweat contains proinflammatory cytokines, IL-1 and IL-31, and activates epidermal keratinocytes as a danger signal. PMID:23874436

  14. Eccrine sweat contains IL-1α, IL-1β and IL-31 and activates epidermal keratinocytes as a danger signal.

    Directory of Open Access Journals (Sweden)

    Xiuju Dai

    Full Text Available Eccrine sweat is secreted onto the skin's surface and is not harmful to normal skin, but can exacerbate eczematous lesions in atopic dermatitis. Although eccrine sweat contains a number of minerals, proteins, and proteolytic enzymes, how it causes skin inflammation is not clear. We hypothesized that it stimulates keratinocytes directly, as a danger signal. Eccrine sweat was collected from the arms of healthy volunteers after exercise, and levels of proinflammatory cytokines in the sweat were quantified by ELISA. We detected the presence of IL-1α, IL-1β, and high levels of IL-31 in sweat samples. To investigate whether sweat activates keratinocytes, normal human keratinocytes were stimulated with concentrated sweat. Western blot analysis demonstrated the activation of NF-κB, ERK, and JNK signaling in sweat-stimulated keratinocytes. Real-time PCR using total RNA and ELISA analysis of supernatants showed the upregulation of IL-8 and IL-1β by sweat. Furthermore, pretreatment with IL-1R antagonist blocked sweat-stimulated cytokine production and signal activation, indicating that bioactive IL-1 is a major factor in the activation of keratinocytes by sweat. Moreover, IL-31 seems to be another sweat stimulator that activates keratinocytes to produce inflammatory cytokine, CCL2. Sweat is secreted onto the skin's surface and does not come into contact with keratinocytes in normal skin. However, in skin with a defective cutaneous barrier, such as atopic dermatitis-affected skin, sweat cytokines can directly act on epidermal keratinocytes, resulting in their activation. In conclusion, eccrine sweat contains proinflammatory cytokines, IL-1 and IL-31, and activates epidermal keratinocytes as a danger signal.

  15. Sodium chloride damage to porous building materials

    NARCIS (Netherlands)

    Lubelli, B.A.

    2006-01-01

    This research studied sodium chloride (NaCl) damage to porous building materials with the aim of: i) gaining a better understanding of the damage process and ii) developing an effective crystallization test. It has been definitely proven that NaCl modifies the hygric dilation of a material

  16. Comparative Effects of Chloride Channel Inhibitors on LRRC8/VRAC-Mediated Chloride Conductance

    Science.gov (United States)

    Friard, Jonas; Tauc, Michel; Cougnon, Marc; Compan, Vincent; Duranton, Christophe; Rubera, Isabelle

    2017-01-01

    Chloride channels play an essential role in a variety of physiological functions and in human diseases. Historically, the field of chloride channels has long been neglected owing to the lack of powerful selective pharmacological agents that are needed to overcome the technical challenge of characterizing the molecular identities of these channels. Recently, members of the LRRC8 family have been shown to be essential for generating the volume-regulated anion channel (VRAC) current, a chloride conductance that governs the regulatory volume decrease (RVD) process. The inhibitory effects of six commonly used chloride channel inhibitors on VRAC/LRRC8-mediated chloride transport were tested in wild-type HEK-293 cells expressing LRRC8 proteins and devoid of other types of chloride channels (CFTR and ANO1/2). We explored the effectiveness of the inhibitors using the patch-clamp whole-cell approach and fluorescence-based quantification of cellular volume changes during hypotonic challenge. Both DCPIB and NFA inhibited VRAC current in a whole-cell configuration, with IC50 values of 5 ± 1 μM and 55 ± 2 μM, respectively. Surprisingly, GlyH-101 and PPQ-102, two CFTR inhibitors, also inhibited VRAC conductance at concentrations in the range of their current use, with IC50 values of 10 ± 1 μM and 20 ± 1 μM, respectively. T16Ainh-A01, a so-called specific inhibitor of calcium-activated Cl- conductance, blocked the chloride current triggered by hypo-osmotic challenge, with an IC50 of 6 ± 1 μM. Moreover, RVD following hypotonic challenge was dramatically reduced by these inhibitors. CFTRinh-172 was the only inhibitor that had almost no effect on VRAC/LRRC8-mediated chloride conductance. All inhibitors tested except CFTRinh-172 inhibited VRAC/LRRC8-mediated chloride conductance and cellular volume changes during hypotonic challenge. These results shed light on the apparent lack of chloride channel inhibitors specificity and raise the question of how these inhibitors

  17. Comparative Effects of Chloride Channel Inhibitors on LRRC8/VRAC-Mediated Chloride Conductance

    Directory of Open Access Journals (Sweden)

    Jonas Friard

    2017-05-01

    Full Text Available Chloride channels play an essential role in a variety of physiological functions and in human diseases. Historically, the field of chloride channels has long been neglected owing to the lack of powerful selective pharmacological agents that are needed to overcome the technical challenge of characterizing the molecular identities of these channels. Recently, members of the LRRC8 family have been shown to be essential for generating the volume-regulated anion channel (VRAC current, a chloride conductance that governs the regulatory volume decrease (RVD process. The inhibitory effects of six commonly used chloride channel inhibitors on VRAC/LRRC8-mediated chloride transport were tested in wild-type HEK-293 cells expressing LRRC8 proteins and devoid of other types of chloride channels (CFTR and ANO1/2. We explored the effectiveness of the inhibitors using the patch-clamp whole-cell approach and fluorescence-based quantification of cellular volume changes during hypotonic challenge. Both DCPIB and NFA inhibited VRAC current in a whole-cell configuration, with IC50 values of 5 ± 1 μM and 55 ± 2 μM, respectively. Surprisingly, GlyH-101 and PPQ-102, two CFTR inhibitors, also inhibited VRAC conductance at concentrations in the range of their current use, with IC50 values of 10 ± 1 μM and 20 ± 1 μM, respectively. T16Ainh-A01, a so-called specific inhibitor of calcium-activated Cl- conductance, blocked the chloride current triggered by hypo-osmotic challenge, with an IC50 of 6 ± 1 μM. Moreover, RVD following hypotonic challenge was dramatically reduced by these inhibitors. CFTRinh-172 was the only inhibitor that had almost no effect on VRAC/LRRC8-mediated chloride conductance. All inhibitors tested except CFTRinh-172 inhibited VRAC/LRRC8-mediated chloride conductance and cellular volume changes during hypotonic challenge. These results shed light on the apparent lack of chloride channel inhibitors specificity and raise the question of how these

  18. Sweat gland tumor (Eccrine Porocarcinoma of scalp: A rare tumor

    Directory of Open Access Journals (Sweden)

    Rana Roshani

    2005-01-01

    Full Text Available Eccrine Porocarcinoma is a rare neoplasm arising from sweat glands. It was first described by Pinkus and Mehregan as ′Epidermotropic eccrine carcinoma′. It may occur de novo or as a malignant transformation of an eccrine poroma. It is commonly found in older age group and in the lower extremities. Clinically, it may present as a verrucous plaque, polypoid growth or an ulcerative lesion of long duration. Local recurrence and metastasis to skin, lymphnodes, viscera, and bone may occur. Treatment is wide local excision. Metastatic lesions can be treated with chemotherapy. We report a case of eccrine porocarcinoma of the scalp in a 50 years old female who presented to us with a bosselated, firm, painless, non-tender, freely mobile swelling over left fronto-parietal region of 12 years duration. It was excised and histopathological diagnosis was Eccrine Porocarcinoma. In literature, scalp porocarcinoma is a very rare tumor.

  19. Sweat: a sample with limited present applications and promising future in metabolomics.

    Science.gov (United States)

    Mena-Bravo, A; Luque de Castro, M D

    2014-03-01

    Sweat is a biofluid with present scant use as clinical sample. This review tries to demonstrate the advantages of sweat over other biofluids such as blood or urine for routine clinical analyses and the potential when related to metabolomics. With this aim, critical discussion of sweat samplers and equipment for analysis of target compounds in this sample is made. Well established routine analyses in sweat as is that to diagnose cystic fibrosis, and the advantages and disadvantages of sweat versus urine or blood for doping control have also been discussed. Methods for analytes such as essential metals and xenometals, ethanol and electrolytes in sweat in fact constitute target metabolomics approaches or belong to any metabolomics subdiscipline such as metallomics, ionomics or xenometabolomics. The higher development of biomarkers based on genomics or proteomics as omics older than metabolomics is discussed and also the potential role of metabolomics in systems biology taking into account its emergent implementation. Normalization of the volume of sampled sweat constitutes a present unsolved shortcoming that deserves investigation. Foreseeable trends in this area are outlined. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A Proteomic Analysis of Eccrine Sweat: Implications for the Discovery of Schizophrenia Biomarker Proteins

    Science.gov (United States)

    Raiszadeh, Michelle M.; Ross, Mark M.; Russo, Paul S.; Schaepper, Mary Ann H.; Zhou, Weidong; Deng, Jianghong; Ng, Daniel; Dickson, April; Dickson, Cindy; Strom, Monica; Osorio, Carolina; Soeprono, Thomas; Wulfkuhle, Julia D.; Kabbani, Nadine; Petricoin, Emanuel F.; Liotta, Lance A.; Kirsch, Wolff M.

    2012-01-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) and multiple reaction monitoring mass spectrometry (MRM-MS) proteomics analyses were performed on eccrine sweat of healthy controls, and the results were compared with those from individuals diagnosed with schizophrenia (SZ). This is the first large scale study of the sweat proteome. First, we performed LC-MS/MS on pooled SZ samples and pooled control samples for global proteomics analysis. Results revealed a high abundance of diverse proteins and peptides in eccrine sweat. Most of the proteins identified from sweat samples were found to be different than the most abundant proteins from serum, which indicates that eccrine sweat is not simply a plasma transudate, and may thereby be a source of unique disease-associated biomolecules. A second independent set of patient and control sweat samples were analyzed by LC-MS/MS and spectral counting to determine qualitative protein differential abundances between the control and disease groups. Differential abundances of selected proteins, initially determined by spectral counting, were verified by MRM-MS analyses. Seventeen proteins showed a differential abundance of approximately two-fold or greater between the SZ pooled sample and the control pooled sample. This study demonstrates the utility of LC-MS/MS and MRM-MS as a viable strategy for the discovery and verification of potential sweat protein disease biomarkers. PMID:22256890

  1. Effects of stimulation technique, anatomical region, and time on human sweat lipid mediator profiles.

    Science.gov (United States)

    Agrawal, Karan; Waller, Justin D; Pedersen, Theresa L; Newman, John W

    2018-01-01

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n=7) was collected weekly for three weeks from the volar forearm following either pilocarpine iontophoresis or exercise, and from the forearm, back and thigh following pilocarpine iontophoresis only. Sweat content of over 150 lipid mediators were measured by liquid chromatography-tandem mass spectrometry. Seventy lipid mediators were routinely detected, including prostanoids, alcohols, diols, epoxides, ketones, nitrolipids, N-acylethanolamides, monoacylglycerols, and ceramides. Detected lipid mediators appeared unaffected by sampling site, though the forearm was the most consistent source of sweat. Pilocarpine-induced sweat showed increased concentrations of most detected compounds. Moreover, lipid mediator concentrations and profiles were temporally stable over the study duration. Sweat therefore appears to be a consistent and anatomically-stable source of lipid mediators, but care must be taken in comparing results obtained from different stimulation techniques. Published by Elsevier Inc.

  2. SWEAT: Snow Water Equivalent with AlTimetry

    Science.gov (United States)

    Agten, Dries; Benninga, Harm-Jan; Diaz Schümmer, Carlos; Donnerer, Julia; Fischer, Georg; Henriksen, Marie; Hippert Ferrer, Alexandre; Jamali, Maryam; Marinaci, Stefano; Mould, Toby JD; Phelan, Liam; Rosker, Stephanie; Schrenker, Caroline; Schulze, Kerstin; Emanuel Telo Bordalo Monteiro, Jorge

    2017-04-01

    To study how the water cycle changes over time, satellite and airborne remote sensing missions are typically employed. Over the last 40 years of satellite missions, the measurement of true water inventories stored in sea and land ice within the cryosphere have been significantly hindered by uncertainties introduced by snow cover. Being able to determine the thickness of this snow cover would act to reduce such error, improving current estimations of hydrological and climate models, Earth's energy balance (albedo) calculations and flood predictions. Therefore, the target of the SWEAT (Snow Water Equivalent with AlTimetry) mission is to directly measure the surface Snow Water Equivalent (SWE) on sea and land ice within the polar regions above 60°and below -60° latitude. There are no other satellite missions currently capable of directly measuring SWE. In order to achieve this, the proposed mission will implement a novel combination of Ka- and Ku-band radioaltimeters (active microwave sensors), capable of penetrating into the snow microstructure. The Ka-band altimeter (λ ≈ 0.8 cm) provides a low maximum snow pack penetration depth of up to 20 cm for dry snow at 37 GHz, since the volume scattering of snow dominates over the scattering caused by the underlying ice surface. In contrast, the Ku-band altimeter (λ ≈ 2 cm) provides a high maximum snowpack penetration depth of up to 15 m in high latitudes regions with dry snow, as volume scattering is decreased by a factor of 55. The combined difference in Ka- and Ku-band signal penetration results will provide more accurate and direct determination of SWE. Therefore, the SWEAT mission aims to improve estimations of global SWE interpreted from passive microwave products, and improve the reliability of numerical snow and climate models.

  3. A Preliminary Study of Biomonitoring for Bisphenol-A in Human Sweat.

    Science.gov (United States)

    Porucznik, Christina A; Cox, Kyley J; Wilkins, Diana G; Anderson, David J; Bailey, Nicole M; Szczotka, Kathryn M; Stanford, Joseph B

    2015-09-01

    Measurement of human exposure to the endocrine disruptor bisphenol-A (BPA) is hampered by the ubiquitous but transient exposure for most individuals, coupled with a short metabolic half-life which leads to high inter- and intra-individual variability. We investigated the possibility of measuring multiday exposure to BPA in human sweat among volunteer participants with the goal of identifying an exposure assessment method less affected by temporal variability. We recruited 50 participants to wear a sweat collection patch (PharmChek(®)) for 7 days with concurrent collection of daily first-morning urine. Urines and sweat patch extracts were analyzed with quantitative LC-MS-MS using a method we previously validated. In addition, a human volunteer consumed one can of commercially available soup (16 oz, 473 cm(3)) daily for 3 days and collected urine. Sweat patches (n = 2, 1 per arm) were worn for the 3 days of the study. BPA was detected in quality control specimens prepared by fortification of BPA to sweat patches, but was only detected at 5× above average background on three participant patches. Although the highest measured urine BPA concentration was 195 ng/mL for an individual with deliberate exposure, no BPA was detected above background in the corresponding sweat patches. In this preliminary investigation, the use of sweat patches primarily worn on the upper-outer arm did not detect BPA exposures that were documented by urine monitoring. The absence of BPA in sweat patches may be due to several factors, including insufficient quantity of specimen per patch, or extremely low concentrations of BPA in naturally occurring sweat, among others. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Accumulation of 2H2O in plasma and eccrine sweat during exercise-heat stress.

    Science.gov (United States)

    Armstrong, Lawrence E; Klau, Jennifer F; Ganio, Matthew S; McDermott, Brendon P; Yeargin, Susan W; Lee, Elaine C; Maresh, Carl M

    2010-02-01

    The purpose of this research was to characterize the movement of ingested water through body fluids, during exercise-heat stress. Deuterium oxide ((2)H(2)O) accumulation in plasma and eccrine sweat was measured at two sites (back and forehead). The exercise of 14 males was controlled via cycle ergometry in a warm environment (60 min; 28.7 degrees C, 51%rh). Subjects consumed (2)H(2)O (0.15 mg kg(-1), 99.9% purity) mixed in flavored, non-caloric, colored water before exercise, then consumed 3.0 ml kg(-1) containing no (2)H(2)O every 15 min during exercise. We hypothesized that water transit from mouth to skin would occur before 15 min. (2)H(2)O appeared rapidly in both plasma and sweat (P deuterium accumulation (DeltaD:H min(-1)) in plasma was 14.9 and 23.7 times greater than in forehead and back sweat samples, respectively. Mean (+/-SE) whole-body sweat rate was 1.04 +/- 0.05 L h(-1) and subjects with the greatest whole-body sweat rate exhibited the greatest peak deuterium enrichment in sweat (r(2) = 0.87, exponential function); the peak (2)H(2)O enrichment in sweat was not proportional (P > 0.05) to body mass, volume of the deuterium dose, or total volume of fluid consumed. These findings clarify the time course of fluid movement from mouth to eccrine sweat glands, and demonstrate considerable differences of (2)H(2)O enrichment in plasma versus sweat.

  5. The response of the malaria mosquito, Anopheles gambiae, to two components of human sweat, ammonia and L-lactic acid, in an olfactometer

    NARCIS (Netherlands)

    Braks, M.A.H.; Meijerink, J.; Takken, W.

    2001-01-01

    In an olfactometer study on the response of the anthropophilic malaria mosquito Anopheles gambiae s.s. (Diptera, Culicidae) to human sweat it was found that freshly collected sweat, mostly of eccrine origin, was attractive, but that incubated sweat was significantly more attractive than fresh sweat.

  6. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    Directory of Open Access Journals (Sweden)

    F. Meyer

    Full Text Available The dependence of sweat composition and acidity on sweating rate (SR suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac- and ammonia (NH3 and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men cycled in the heat (42ºC, 20% relative humidity at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 ± 1.2 and 21.2 ± 1.7 mM; P 0.05; r = -0.27. Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 ± 0.4 mM. Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 ± 0.4, boys = 4.6 ± 0.6, women = 2.7 ± 0.2, and men = 3.0 ± 0.2 mM; P < 0.05. This difference persisted through bout 2 only in females. On average, children's sweat pH was lower than that of adults (mean ± SEM, girls = 5.4 ± 0.2, boys = 5.0 ± 0.1, women = 6.2 ± 0.5, and men = 6.2 ± 0.4 for bout 1, and girls = 5.4 ± 0.2, boys = 6.5 ± 0.5, women = 5.2 ± 0.2, and men = 6.9 ± 0.4 for bout 2. This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56. Blood pH increased from rest (mean ± SEM; 7.3 ± 0.02 to the end of exercise (7.4 ± 0.01 without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  7. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    Directory of Open Access Journals (Sweden)

    F. Meyer

    2007-01-01

    Full Text Available The dependence of sweat composition and acidity on sweating rate (SR suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac- and ammonia (NH3 and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men cycled in the heat (42ºC, 20% relative humidity at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 ± 1.2 and 21.2 ± 1.7 mM; P 0.05; r = -0.27. Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 ± 0.4 mM. Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 ± 0.4, boys = 4.6 ± 0.6, women = 2.7 ± 0.2, and men = 3.0 ± 0.2 mM; P < 0.05. This difference persisted through bout 2 only in females. On average, children's sweat pH was lower than that of adults (mean ± SEM, girls = 5.4 ± 0.2, boys = 5.0 ± 0.1, women = 6.2 ± 0.5, and men = 6.2 ± 0.4 for bout 1, and girls = 5.4 ± 0.2, boys = 6.5 ± 0.5, women = 5.2 ± 0.2, and men = 6.9 ± 0.4 for bout 2. This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56. Blood pH increased from rest (mean ± SEM; 7.3 ± 0.02 to the end of exercise (7.4 ± 0.01 without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  8. Wearable sweat detector device design for health monitoring and clinical diagnosis

    Science.gov (United States)

    Wu, Qiuchen; Zhang, Xiaodong; Tian, Bihao; Zhang, Hongyan; Yu, Yang; Wang, Ming

    2017-06-01

    Miniaturized sensor is necessary part for wearable detector for biomedical applications. Wearable detector device is indispensable for online health care. This paper presents a concept of an wearable digital health monitoring device design for sweat analysis. The flexible sensor is developed to quantify the amount of hydrogen ions in sweat and skin temperature in real time. The detection system includes pH sensor, temperature sensor, signal processing module, power source, microprocessor, display module and so on. The sweat monitoring device is designed for sport monitoring or clinical diagnosis.

  9. Analysis of methamphetamine in hair, nail, sweat, and saliva by mass fragmentography.

    Science.gov (United States)

    Suzuki, S; Inoue, T; Hori, H; Inayama, S

    1989-01-01

    A method for the detection and quantitation of methamphetamine and its major metabolite in hair, nails, sweat, and saliva from habitual users of methamphetamine by mass fragmentography has been developed. Hair and nail samples were washed with water and methanol to remove the external contamination, processed with 0.6M HCl, alkalinized, and extracted with CHCl3/isopropanol (3:1 v/v). Sweat and saliva samples were extracted with methanol. After trifluoroacetyl derivatization, the samples were analyzed by mass fragmentography. Methamphetamine and its major metabolite, amphetamine, were detected in hair, nail, and sweat samples, but methamphetamine alone was detected in saliva samples.

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... process. A complete diagnostic evaluation should include a newborn screening, a sweat chloride test, a genetic or ... Screened in IRT-Only vs. IRT-DNA States Newborn Screening for CF Sweat Test Life With CF ...

  11. Abnormal Axon Reflex-Mediated Sweating Correlates with High State of Anxiety in Atopic Dermatitis

    Directory of Open Access Journals (Sweden)

    Akiko Kijima

    2012-01-01

    Conclusions: Although the number of study subjects was little, abnormal AXR sweating in patients with AD was observed. Correlative analysis suggests possible involvement of continuous anxiety and the immune system in such abnormal sudomotor function.

  12. Congenital chloride diarrhea: late presentation

    Directory of Open Access Journals (Sweden)

    Al Bishi L

    2011-04-01

    Full Text Available Laila Al Bishi1, Mustafa Al Toonisi2Pediatric Department, North West Armed Forces Hospital, Tabuk, Kingdom of Saudi ArabiaAbstract: We report the case of a male infant who presented with diarrhea at 6 months of age. He was failing to thrive, and biochemical investigation revealed hypokalemic hypochloremic metabolic alkalosis. Diagnosis of congenital chloride diarrhea was suspected and confirmed by the stool chloride result. He was started on high-dose sodium chloride and potassium chloride to control the electrolyte imbalance. The disease was difficult to control for a year after diagnosis. Late presentation is associated with severe chronic electrolyte disturbances and high-dose replacement therapy.Keywords: congenital chloride diarrhea, hypokalemic hypochloremic metabolic alkalosis, high stool chloride

  13. Chloride is essential for contraction of afferent arterioles after agonists and potassium

    DEFF Research Database (Denmark)

    Jensen, B L; Ellekvist, Peter; Skøtt, O

    1997-01-01

    A depolarizing chloride efflux has been suggested to activate voltage-dependent calcium channels in renal afferent arteriolar smooth muscle cells in response to vasoconstrictors. To test this proposal, rabbit afferent arterioles were microperfused, and the contractile dose responses...... chloride. We conclude that norepinephrine and ANG II use different mechanisms for contraction and that extracellular chloride is essential for contraction in afferent arterioles after activation of voltage-dependent calcium channels. We suggest that a chloride influx pathway is activated concomitantly...

  14. [Effectiveness of new quarternary ammonium chloride compounds against selected bacteria and fungi. XXI. Synthesis of alkoxymethyl-3,4-dimethyl- pyridine and 1-ethyloxymethyl-3-alkylthiomethylimidazole chlorides].

    Science.gov (United States)

    Pernak, J; Krysiński, J; Skrzypczak, A; Michalak, L

    1989-01-01

    Syntheses and antibacterial properties of alkoxymethyl-3,4-dimethylpyridinium chlorides and 1-ethyloxymethyl-3-alkylthiomethylimidazolium chlorides are described. Alkoxymetgyl-3,4-dimethylpyridinium chlorides were synthetized by reacting 3,4-dimethylpyridine with chloromethyl alkyl ethers, while 1-ethyloxymethyl-3-alkylthiomethylimidazolium chlorides were obtained in reactions of 1-ethyloxymethylimidazol with chloromethyl alkyl sulfides. Antibacterial properties of the obtained compounds were tested on 13 strains of bacteria and fungi. Strong bacteriostatic activity was found to be displayed by iminium chlorides with octyloxymethyl, decyloxymethyl, octylthiomethyl and decylthiomethyl groups.

  15. Sweat Rate Prediction Equations for Outdoor Exercise with Transient Solar Radiation

    Science.gov (United States)

    2012-01-01

    clothing, aerobic fitness, and progressive dehydration . J Therm Biol 22: 331–342, 1997. 25. Matthew WT, Santee WR, Berglund LG. Solar Load Inputs for...code) Sweat rate prediction equations for outdoor exercise with transient solar radiation Richard R. Gonzalez,1 Samuel N. Cheuvront,2 Brett R. Ely,2...Moran DS, Hadid A, Endrusick TL, Sawka MN. Sweat rate prediction equations for outdoor exercise with transient solar radiation. J Appl Phys- iol 112

  16. A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)

    OpenAIRE

    Munje, Rujuta D.; Muthukumar, Sriram; Jagannath, Badrinath; Prasad, Shalini

    2017-01-01

    Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membran...

  17. Hydration profile and sweat loss perception of male and female division II basketball players during practice.

    Science.gov (United States)

    Thigpen, Lauren K; Green, James M; OʼNeal, Eric K

    2014-12-01

    Hydration affects multiple aspects of basketball performance, but few investigations have examined the hydration profiles of collegiate basketball players. We examined multiday prepractice hydration status of 11 male and 11 female NCAA (National Collegiate Athletic Association) Division II basketball players' sweat losses, fluid intake, and how accurately players estimated their sweat losses. Urine-specific gravity (USG) was spontaneously assessed before 2 practices. Sweat losses and fluid intakes were measured during a conditioning practice (CP) and sport-specific practice (SP). After practices, players filled 1,030 ml practice bottles to estimate their sweat losses. Urine-specific gravity between practices exhibited a moderate correlation (r = 0.54; p = 0.012) and were consistently high (17% of samples = USG >1.030) with no difference in mean USG between men (1.026 ± 0.004) and women (1.022 ± 0.008). Athletes' estimations of their sweat loss volumes between CP and the longer SP were strongly correlated (r = 0.88; p < 0.001). Estimation error was high (absolute error for both practices = 71 ± 52%) and error direction varied greatly within men. Women consistently underestimated sweat losses by 63 ± 28% and 65 ± 20% during CP and SP. Sweat losses during SP equaled 2,471 ± 495 ml and 1,910 ± 441 ml for men and women, respectively, but high practice fluid intake limited body mass losses to 1.1 ± 0.6% by the end of practice. It is plausible that hypohydration is related to poor conceptualization of sweat losses. Simulating the methodology of this study could help identify chronically hypohydrated athletes and be used to educate on between-practice fluid needs.

  18. A COMPARATIVE HISTOLOGICAL STUDY ON THE SWEAT GLAND OF CATTLE (B. INDICUS AND YAK (P. POEPHAGUS

    Directory of Open Access Journals (Sweden)

    Partha Das

    2014-12-01

    Full Text Available Yak and cattle are the species of different habitats, but are of the same genus Bos. In order to adapt to different habitats some changes may occur in cellular organizations, sweat gland morphology being one of the part of this cellular organization. The skin samples were collected from six adult nondescript male cattle and yak from five different anatomical regions viz., neck, dewlap, abdomen, back and prepuce. Sweat glands appeared tubular consisting of a secretary coil which was embedded in the dermis in cattle. In yak, the glands were saccular in the neck and dewlap regions and tubular in other regions. The sweat gland number (1729±3.44 in cattle was almost three times higher (P<0.01 than yak (615.82±3.44.Highest number of sweat gland population was found in back (1563.24±5.44 and lowest in abdomen (900.26±5.44 in both the species. Descending order of sweat gland number was detected in dewlap, neck and prepuce respectively in both the species. In cattle the sweat gland diameter was significantly (32.78±0.38 µm higher as compared to yak (27.68±0.38 ìm. The sweat gland number and nuclear diameter in cattle was more than yak. Acidophilic secretory granules of the glands were numerous in the supra-nuclear cytoplasm in case of cattle. These results suggest the hyper activity of sweat gland in controlling the thermo dynamics in cattle as compared to yak.

  19. Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat (Postprint)

    Science.gov (United States)

    2016-05-04

    lactate dehydrogenase; energy harvester (EH); micropotentiostat (MP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT: SAR 18. NUMBER OF...Band-Aid like RFID sensor patches and temporary tattoo-based sensors have been developed for electrolyte and lactate sensing in sweat as part of on...2008. ISABEL’08. First International Symposium on. 2008. IEEE. 27. D. P. Rose et al., “Adhesive RFID sensor patch for monitoring of sweat electrolytes

  20. Does Replacing Sodium Excreted in Sweat Attenuate the Health Benefits of Physical Activity?

    Science.gov (United States)

    Turner, Martin J; Avolio, Alberto P

    2016-08-01

    International guidelines suggest limiting sodium intake to 86-100 mmol/day, but average intake exceeds 150 mmol/day. Participants in physical activities are, however, advised to increase sodium intake before, during and after exercise to ensure euhydration, replace sodium lost in sweat, speed rehydration and maintain performance. A similar range of health benefits is attributable to exercise and to reduction in sodium intake, including reductions in blood pressure (BP) and the increase of BP with age, reduced risk of stroke and other cardiovascular diseases, and reduced risk of osteoporosis and dementia. Sweat typically contains 40-60 mmol/L of sodium, leading to approximately 20-90 mmol of sodium lost in one exercise session with sweat rates of 0.5-1.5 L/h. Reductions in sodium intake of 20-90 mmol/day have been associated with substantial health benefits. Homeostatic systems reduce sweat sodium as low as 3-10 mmol/L to prevent excessive sodium loss. "Salty sweaters" may be individuals with high sodium intake who perpetuate their "salty sweat" condition by continual replacement of sodium excreted in sweat. Studies of prolonged high intensity exercise in hot environments suggest that sodium supplementation is not necessary to prevent hyponatremia during exercise lasting up to 6 hr. We examine the novel hypothesis that sodium excreted in sweat during physical activity offsets a significant fraction of excess dietary sodium, and hence may contribute part of the health benefits of exercise. Replacing sodium lost in sweat during exercise may improve physical performance, but may attenuate the long-term health benefits of exercise.

  1. Thin, Soft, Skin-Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono-Sampling of Sweat.

    Science.gov (United States)

    Choi, Jungil; Kang, Daeshik; Han, Seungyong; Kim, Sung Bong; Rogers, John A

    2017-03-01

    Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat-induced fluid flows for sample isolation. Here, a thin, soft, "skin-like" microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm 2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min -1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Effect of chloride-based deicers on reinforced concrete structures.

    Science.gov (United States)

    2012-07-01

    We conducted an extensive literature review and performed laboratory tests to assess the effect of chloride-based deicers on the rebars and dowel bars in concrete and to determine whether or not deicer corrosion inhibitors help preserve the transport...

  3. Estimation of sweat rates during cycling exercise by means of the closed chamber condenser technology.

    Science.gov (United States)

    Clarys, P; Clijsen, R; Barel, A O; Schouteden, R; van Olst, B; Aerenhouts, D

    2017-02-01

    Knowledge of local sweating patterns is of importance in occupational and exercise physiology settings. The recently developed closed chamber condenser technology (Biox Aquaflux ® ) allows the measurement of evaporative skin water loss with a greater measurement capacity (up to 1325 g/h/m 2 ) compared to traditional evaporimeters. The aim of this study was to evaluate the applicability of the Biox Aquaflux ® to estimate sweat production during exercise. Fourteen healthy subjects performed a 20-min cycle ergometer trial at respectively 55% heart rate (HR reserve and 75% HR reserve . Sweat production was estimated by measuring body weight before and after exercise, by calculating the amount of sweat collected in a patch, and by measuring the water flux (in g/h/m 2 ) with the Biox Aquaflux ® instrument. The Biox Aquaflux ® instrument allowed the follow up of sweat kinetics at both intensities. Correlations between the measurement methods were all significant for the 75% HR reserve trial (with r ranging from 0.68 to 0.76) whilst for the 55% HR reserve a significant relation was detected between the patch method and the Biox Aquaflux ® only (with r ranging from 0.41 to 0.79). The Biox Aquaflux ® instrument is a practical and direct method for the estimation of local sweat rates under field conditions. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Noninvasive monitoring of plasma L-dopa concentrations using sweat samples in Parkinson's disease.

    Science.gov (United States)

    Tsunoda, Makoto; Hirayama, Masaaki; Tsuda, Takao; Ohno, Kinji

    2015-03-10

    L-dopa (l-3,4-dihydroxyphenylalanine) is commonly used for treating Parkinson's disease (PD). However, regardless of its prominent effect, therapeutic range of L-dopa narrows down with disease progression, which leads to development of motor complications including wearing off and dyskinesias. In addition, intestinal absorption of L-dopa is inversely correlated with the amount of oral protein intake, and shows intra- and inter-day variability. Hence, frequent monitoring of plasma L-dopa concentrations is beneficial, but frequent venipuncture imposes physical and psychological burdens on patients with PD. We investigated the usefulness of sweat samples instead of plasma samples for monitoring L-dopa concentrations. With a monolithic silica disk-packed spin column and the high-performance liquid chromatography-electrochemical detection system, L-dopa in sweat samples was successfully quantified and analyzed in 23 PD patients. We found that the Pearson's correlation coefficient of the plasma and sweat l-dopa concentrations was 0.678. Although the disease durations and severities were not correlated with the deviation of the actual sweat L-dopa concentrations from the fitted line, acquisition of the sweat samples under a stable condition was technically difficult in severely affected patients. The deviations may also be partly accounted for by skin permeability of L-dopa. Measuring L-dopa concentrations in sweat is suitable to get further insights into the L-dopa metabolism. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module

    Science.gov (United States)

    Lee, Hyunjae; Song, Changyeong; Hong, Yong Seok; Kim, Min Sung; Cho, Hye Rim; Kang, Taegyu; Shin, Kwangsoo; Choi, Seung Hong; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2017-01-01

    Electrochemical analysis of sweat using soft bioelectronics on human skin provides a new route for noninvasive glucose monitoring without painful blood collection. However, sweat-based glucose sensing still faces many challenges, such as difficulty in sweat collection, activity variation of glucose oxidase due to lactic acid secretion and ambient temperature changes, and delamination of the enzyme when exposed to mechanical friction and skin deformation. Precise point-of-care therapy in response to the measured glucose levels is still very challenging. We present a wearable/disposable sweat-based glucose monitoring device integrated with a feedback transdermal drug delivery module. Careful multilayer patch design and miniaturization of sensors increase the efficiency of the sweat collection and sensing process. Multimodal glucose sensing, as well as its real-time correction based on pH, temperature, and humidity measurements, maximizes the accuracy of the sensing. The minimal layout design of the same sensors also enables a strip-type disposable device. Drugs for the feedback transdermal therapy are loaded on two different temperature-responsive phase change nanoparticles. These nanoparticles are embedded in hyaluronic acid hydrogel microneedles, which are additionally coated with phase change materials. This enables multistage, spatially patterned, and precisely controlled drug release in response to the patient’s glucose level. The system provides a novel closed-loop solution for the noninvasive sweat-based management of diabetes mellitus. PMID:28345030

  6. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research[S

    Science.gov (United States)

    Hassoun, Lauren A.; Foolad, Negar; Pedersen, Theresa L.; Sivamani, Raja K.; Newman, John W.

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30–C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs. PMID:27875258

  7. Stretchable, wireless sensors and functional substrates for epidermal characterization of sweat.

    Science.gov (United States)

    Huang, Xian; Liu, Yuhao; Chen, Kaile; Shin, Woo-Jung; Lu, Ching-Jui; Kong, Gil-Woo; Patnaik, Dwipayan; Lee, Sang-Heon; Cortes, Jonathan Fajardo; Rogers, John A

    2014-08-13

    This paper introduces materials and architectures for ultrathin, stretchable wireless sensors that mount on functional elastomeric substrates for epidermal analysis of biofluids. Measurement of the volume and chemical properties of sweat via dielectric detection and colorimetry demonstrates some capabilities. Here, inductively coupled sensors consisting of LC resonators with capacitive electrodes show systematic responses to sweat collected in microporous substrates. Interrogation occurs through external coils placed in physical proximity to the devices. The substrates allow spontaneous sweat collection through capillary forces, without the need for complex microfluidic handling systems. Furthermore, colorimetric measurement modes are possible in the same system by introducing indicator compounds into the depths of the substrates, for sensing specific components (OH(-) , H(+) , Cu(+) , and Fe(2+) ) in the sweat. The complete devices offer Young's moduli that are similar to skin, thus allowing highly effective and reliable skin integration without external fixtures. Experimental results demonstrate volumetric measurement of sweat with an accuracy of 0.06 μL/mm(2) with good stability and low drift. Colorimetric responses to pH and concentrations of various ions provide capabilities relevant to analysis of sweat. Similar materials and device designs can be used in monitoring other body fluids. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Rate and composition of sweat fluid losses are unaltered by hypohydration during prolonged exercise in horses.

    Science.gov (United States)

    Kingston, J K; Geor, R J; McCutcheon, L J

    1997-10-01

    Rate and ionic composition of sweat fluid losses and partitioning of evaporative heat loss into respiratory and cutaneous components were determined in six horses during three 15-km phases of exercise at approximately 40% of maximal O2 uptake. Pattern of change in sweat rate (SR) and composition was similar during each phase. SR increased rapidly for the first 20 min of exercise but remained at approximately 24-28 ml . m-2 . min-1 during the remainder of each phase. Similarly, the concentrations of Na and Cl in sweat increased until 30 min of exercise but were unchanged thereafter. Sweat osmolality and concentrations of Na and Cl were positively correlated with SR. Sweat K concentration decreased during exercise but was not correlated with SR. Fluid losses were 33.8 +/- 1.5 liters, resulting in decreases of approximately 21% in plasma volume and approximately 11% in total body water. The approximately 6% hypohydration was not associated with an alteration in SR, sweat composition, or heat storage. Respiratory and cutaneous evaporative heat loss represented approximately 23 and 70%, respectively, of the total heat dissipated, and the partitioning of heat loss was similar in each exercise phase. We conclude that SR and the relative proportions of respiratory and cutaneous evaporative heat loss are unchanged in horses during prolonged low-intensity exercise despite moderate hypohydration.

  9. A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs).

    Science.gov (United States)

    Munje, Rujuta D; Muthukumar, Sriram; Jagannath, Badrinath; Prasad, Shalini

    2017-05-16

    Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membranes. Temporal studies were performed using both infrared spectroscopic, dynamic light scattering, and impedimetric spectroscopy to demonstrate stability in detection of analytes, Interleukin-6 (IL-6) and Cortisol, from human sweat in RTILs. Temporal stability in sensor performance was performed as follows: (a) detection of target analytes after 0, 24, 48, 96, and 168 hours post-antibody sensor functionalization; and (b) continuous detection of target analytes post-antibody sensor functionalization. Limit of detection of IL-6 in human sweat was 0.2 pg/mL for 0-24 hours and 2 pg/mL for 24-48 hours post-antibody sensor functionalization. Continuous detection of IL-6 over 0.2-200 pg/mL in human sweat was demonstrated for a period of 10 hours post-antibody sensor functionalization. Furthermore, combinatorial detection of IL-6 and Cortisol in human sweat was established with minimal cross-talk for 0-48 hours post-antibody sensor functionalization.

  10. Control of sweating in man after work-induced thermal load and symmetrically applied cooling.

    Science.gov (United States)

    Heising, M; Werner, J

    1987-01-01

    To examine the compensatory effects of work-induced thermal load and symmetrically applied local cooling on local sweat rates, two kinds of experiment were carried out on eight male subjects in a climatic chamber: 1) Experiments at 36 degrees C ambient temperature with a work load of about 25 W by the right leg. 2) Experiments at 36 degrees C ambient temperature with a work load of about 25 W by the right leg as in 1., but with additional compensatory cooling of the left leg controlled throughout by heat balance calculations at 75-85 W, equal to the heat produced in the working leg, the necessary air temperature being dependent on local sweat rate. Work load without cooling brought about a significant increase in core temperatures, metabolism, heart rate and local sweat rates. With unchanged local skin temperatures local sweat rate increase was higher in the working leg. Therefore the existence of muscle thermoreceptors should be assumed, the afferent information from which is processed and weighted in a different way to that provided by skin receptors. Work load combined with additional cooling reduced local and mean skin temperatures and heart rate, but had no significant influence on core temperature or metabolism. However, local sweat rate was generally lower in both thighs, with a major reduction in the cooled leg confirming control of local sweat rate by local temperature.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Normative data on regional sweat-sodium concentrations of professional male team-sport athletes.

    Science.gov (United States)

    Ranchordas, Mayur K; Tiller, Nicholas B; Ramchandani, Girish; Jutley, Raj; Blow, Andrew; Tye, Jonny; Drury, Ben

    2017-01-01

    The purpose of this paper was to report normative data on regional sweat sweat-sodium concentrations of various professional male team-sport athletes, and to compare sweat-sodium concentrations among sports. Data to this effect would inform our understanding of athlete sodium requirements, thus allowing for the individualisation of sodium replacement strategies. Accordingly, data from 696 athletes (Soccer, n = 270; Rugby, n = 181; Baseball, n = 133; American Football, n = 60; Basketball, n = 52) were compiled for a retrospective analysis. Regional sweat-sodium concentrations were collected using the pilocarpine iontophoresis method, and compared to self-reported measures collected via questionnaire. Sweat-sodium concentrations were significantly higher (p sports. There were strong positive correlations between sweat-sodium concentrations and self-reported sodium losses in American football (rs = 0.962, p sports science/medicine practitioners in generating bespoke hydration and electrolyte-replacement strategies to meet the sodium demands of professional team-sport athletes. Moreover, these novel data suggest that self-reported measures of sodium loss might serve as an effective surrogate in the absence of direct measures; i.e., those which are more expensive or non-readily available.

  12. Maximum rate of sweat ions reabsorption during exercise with regional differences, sex, and exercise training.

    Science.gov (United States)

    Amano, Tatsuro; Hirose, Megumi; Konishi, Kana; Gerrett, Nicola; Ueda, Hiroyuki; Kondo, Narihiko; Inoue, Yoshimitsu

    2017-07-01

    It is recently reported that determining sweat rate (SR) threshold for increasing galvanic skin conductance (GSC) would represent a maximum rate of sweat ion reabsorption in sweat glands. We evaluate the maximum rate of sweat ion reabsorption over skin regions, sex, and long-term exercise training by using the threshold analysis in the present study. Ten males (2 untrained, 4 sprinters, and 4 distance runners) and 12 females (5 untrained, 4 sprinters, and 3 distance runners) conducted graded cycling exercise for 45 min at low, middle, and high exercise intensities (heart rate 100-110, 120-130, and 140-150 beats/min, respectively) for 10, 15, and 20 min, respectively, at 30 °C and 50% relative humidity. Comparisons were made between males and females and among untrained individuals, distance runners, and sprinters on the back and forearm. SR threshold for increasing GSC on back was significantly higher than that of forearm (P sprinters showed higher SR threshold for increasing GSC than that of untrained subjects on back (P sprinters, respectively). These results suggest that the maximum sweat ion reabsorption rate on the back is higher than that of forearm without sex differences. Furthermore, exercise training in distance runners and sprinters improves the maximum sweat ion reabsorption rate on the back.

  13. Corrosion Performance of Cu-Based Coins in Artificial Sweat

    Directory of Open Access Journals (Sweden)

    J. Porcayo-Calderon

    2016-01-01

    Full Text Available The performance of different Cu-based coins in artificial sweat was evaluated. The electrochemical behavior of the coins was determined by potentiodynamic polarization curves, linear polarization resistance, and electrochemical impedance spectroscopy. Regardless of the chemical composition of the Cu-based coins, they showed similar polarization curves; particularly, the observed similarity in the anodic zone suggests that the corrosion mechanism is the same in all cases. The presence of Ni and Zn does not appreciably affect the corrosion resistance of Cu. However, the presence of both elements affects the corrosion resistance of Cu. Electrochemical impedance spectroscopy measurements showed the presence of three time constants with very similar characteristics, again indicating that the main corrosion mechanism is the same in all cases. Equivalent circuits confirmed that the corrosion performance of the Ni-Zn-Cu coins depends on the Zn/Ni ratio, such that decreasing this value decreases the corrosion resistance of the alloy. In general, nickel has a detrimental effect due to the formation of highly soluble Ni-based corrosion products.

  14. Chloride on the Move

    KAUST Repository

    Li, Bo

    2017-01-09

    Chloride (Cl−) is an essential plant nutrient but under saline conditions it can accumulate to toxic levels in leaves; limiting this accumulation improves the salt tolerance of some crops. The rate-limiting step for this process – the transfer of Cl− from root symplast to xylem apoplast, which can antagonize delivery of the macronutrient nitrate (NO3−) to shoots – is regulated by abscisic acid (ABA) and is multigenic. Until recently the molecular mechanisms underpinning this salt-tolerance trait were poorly defined. We discuss here how recent advances highlight the role of newly identified transport proteins, some that directly transfer Cl− into the xylem, and others that act on endomembranes in ‘gatekeeper’ cell types in the root stele to control root-to-shoot delivery of Cl−.

  15. Normal sweat secretion despite impaired growth hormone-insulin-like growth factor-I axis in obese subjects

    DEFF Research Database (Denmark)

    Rasmussen, Michael Højby; Juul, Anders; Main, Katharina M

    2011-01-01

    Adults with GH deficiency are known to exhibit reduced sweating. Whether sweating capacity is impacted in obese subjects with impaired GH secretion have not previously been investigated. The main objective was to investigate sweat secretion rate and the GH-IGF-I axis in obese subjects before......, and impaired insulin sensitivity, which all were normalised after diet-induced weight loss of 30 ± 5 kg. Sweat secretion rates were similar comparing obese and nonobese subjects (78 ± 10 versus 82 ± 9 mg/30 minutes) and sweat secretion did not change after a diet-induced weight loss in obese subjects. We...... conclude that although obese subjects have markedly reduced GH release and impaired IGF-I levels, sweat secretion rate is found to be normal....

  16. Increase in dermcidin-derived peptides in sweat of patients with atopic eczema caused by a humorous video.

    Science.gov (United States)

    Kimata, Hajime

    2007-01-01

    Dermcidin (DCD)-derived peptide is an antimicrobial peptide produced by the sweat glands. However, the levels of DCD-derived peptide in sweat were decreased in patients with atopic eczema (AE). The effect of viewing a humorous video on the levels of DCD-derived peptide was studied. Twenty patients with AE viewed an 87-min humorous video (Modern Times, featuring Charlie Chaplin). Just before and immediately after viewing, sweat was collected, and the levels of DCD-derived peptide and total protein in sweat were measured. Viewing a humorous video increased the levels of DCD-derived peptide without affecting the levels of total protein in sweat. Viewing a humorous video increased DCD-derived peptide in sweat of patients with AE, and thus, it may be helpful in the treatment of skin infection of AE.

  17. Effects of CPU 86017 (chlorobenzyltetrahydroberberine chloride) and its enantiomers on thyrotoxicosis-induced overactive endothelin-1 system and oxidative stress in rat testes.

    Science.gov (United States)

    Tang, XiaoYun; Qi, MinYou; Dai, DeZai; Zhang, Can

    2006-08-01

    To study the effects of CPU 86017, a berberine derivative, and its four enantiomers on thyrotoxicosis-induced oxidative stress and the excessive endothelin-1 system in rat testes. Adult male SD rats were given high-dose L-thyroxin (0.2 mg/kg subcutaneously) once daily for 10 days to develop thyrotoxicosis. Subsets of the rats were treated with CPU 86017 or its four enantiomers (SR, SS, RS, and RR) once daily from day 6 to day 10. The alterations of redox, nitric oxide synthase, and endothelin-1 system in testes were examined by spectrophotometry and reverse transcriptase-polymerase chain reaction assay. After 10 days of high-dose L-thyroxin administration, increased mRNA expression of prepro-endothelin-1 and endothelin-converting enzyme was observed in the rat testes, accompanied by an elevated inducible nitric oxide synthase activity and oxidative stress. CPU 86017 and its enantiomer SR significantly improved these abnormalities. High-dose L-thyroxin results in an overactive endothelin-1 system and oxidative stress in adult rat testis. CPU 86017 and its enantiomer SR suppressed the excessive ET-1 system by improving oxidative stress, and SR exhibited more potent efficacy than CPU 86017 and other enantiomers.

  18. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Science.gov (United States)

    2010-07-01

    ... operator is not required to conduct an emission test for HCl. (f) Sweat furnace. Except as provided in § 63.1505(f)(1), the owner or operator must measure emissions of D/F from each sweat furnace at the outlet... gaseous or liquid reactive flux for the 3 test runs; (2) Record the identity, composition, and total...

  19. Measurement of atmospheric vinyl chloride.

    Science.gov (United States)

    Lande, S S

    1979-02-01

    Methods for atmospheric vinyl chloride measurement have been reviewed. The lowest detection limits and most specific measurement are achieved by scrubbing atmospheric samples with activated charcoal, desorbing the vinyl chloride, and assaying it by gas chromatography (GC). NIOSH currently recommends collecting samples using tubes packed with 150 mg of coconut shell charcoal, desorbing with carbon disulfide, and analyzing by GC equipped with flame-ionization detection (FID); the method is capable of detecting less than 1 ppm vinyl chloride and has an apparent recovery of abo the ppb level with no loss of accuracy or precision. Some field methods, such as infrared analysis and conductivity measurement, are capable of detecting 1 ppm or lower but are subject to interferences by other contaminants; th-y could be useful for evaluating sources of vinyl chloride leaks and for continuous monitoring. Permeation tubes are superior to gravimetric or volumetric methods for generating atmospheres of known vinyl chloride concentration.

  20. Specificity of granular IgM deposition in folliculosebaceous units and sweat gland apparatus in direct immunofluorescence (DIF) of lupus erythematosus.

    Science.gov (United States)

    Elbendary, Amira; Zhou, Cheng; Valdebran, Manuel; Yu, Yan; Gad, AbdAllah; Kwon, Eun Ji; Elston, Dirk M

    2016-08-01

    Diagnosis of lupus erythematosus (LE) in direct immunofluorescence testing is based on the finding of positive immunofluorescence at the dermoepidermal junction (DEJ). We sought to evaluate the sensitivity of IgM deposition at the DEJ and adnexal structures in the diagnosis of lupus erythematosus. We conducted a retrospective study of 100 previously diagnosed cases of lupus erythematosus and 158 cases of other immune-mediated dermatosis. Deposition of IgG, IgM, IgA, and C3 at the DEJ, follicular units, and sweat glands were recorded. Presence or absence of adnexal structures was documented. The immunoreactant deposition was documented as linear, coarse granular, or stippled. The most frequently deposited immunoreactant in lupus erythematosus cases was IgM along the DEJ and stromal-epithelial junction of hair follicles and sweat glands. IgM deposition along the stromal-epithelial junction of hair follicles and sweat glands was strongly associated with a diagnosis of lupus erythematosus compared with other immune-mediated diseases collectively (P value < .001). The pattern of IgM in lupus and dermatomyositis is granular, in contrast to the linear deposition in the other disorders evaluated. This was a retrospective study of archived material. Granular IgM deposition at the stromal-epithelial junction of cutaneous adnexal structures suggests a diagnosis of lupus erythematosus or dermatomyositis. Copyright © 2016 American Academy of Dermatology, Inc. All rights reserved.

  1. 40 CFR 61.65 - Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants.

    Science.gov (United States)

    2010-07-01

    ... dichloride, vinyl chloride and polyvinyl chloride plants. 61.65 Section 61.65 Protection of Environment... dichloride, vinyl chloride and polyvinyl chloride plants. An owner or operator of an ethylene dichloride, vinyl chloride, and/or polyvinyl chloride plant shall comply with the requirements of this section. (a...

  2. Epidermal Microfluidic Electrochemical Detection System: Enhanced Sweat Sampling and Metabolite Detection.

    Science.gov (United States)

    Martín, Aida; Kim, Jayoung; Kurniawan, Jonas F; Sempionatto, Juliane R; Moreto, Jose R; Tang, Guangda; Campbell, Alan S; Shin, Andrew; Lee, Min Yul; Liu, Xiaofeng; Wang, Joseph

    2017-12-22

    Despite tremendous recent efforts, noninvasive sweat monitoring is still far from delivering its early analytical promise. Here, we describe a flexible epidermal microfluidic detection platform fabricated through hybridization of lithographic and screen-printed technologies, for efficient and fast sweat sampling and continuous, real-time electrochemical monitoring of glucose and lactate levels. This soft, skin-mounted device judiciously merges lab-on-a-chip and electrochemical detection technologies, integrated with a miniaturized flexible electronic board for real-time wireless data transmission to a mobile device. Modeling of the device design and sweat flow conditions allowed optimization of the sampling process and the microchannel layout for achieving attractive fluid dynamics and rapid filling of the detection reservoir (within 8 min from starting exercise). The wearable microdevice thus enabled efficient natural sweat pumping to the electrochemical detection chamber containing the enzyme-modified electrode transducers. The fabricated device can be easily mounted on the epidermis without hindrance to the wearer and displays resiliency against continuous mechanical deformation expected from such epidermal wear. Amperometric biosensing of lactate and glucose from the rapidly generated sweat, using the corresponding immobilized oxidase enzymes, was wirelessly monitored during cycling activity of different healthy subjects. This ability to monitor sweat glucose levels introduces new possibilities for effective diabetes management, while similar lactate monitoring paves the way for new wearable fitness applications. The new epidermal microfluidic electrochemical detection strategy represents an attractive alternative to recently reported colorimetric sweat-monitoring methods, and hence holds considerable promise for practical fitness or health monitoring applications.

  3. Stability study of carboplatin infusion solutions in 0.9% sodium chloride in polyvinyl chloride bags.

    Science.gov (United States)

    Myers, Alan L; Zhang, Yang-Ping; Kawedia, Jitesh D; Trinh, Van A; Tran, Huyentran; Smith, Judith A; Kramer, Mark A

    2016-02-01

    Carboplatin is a platinum-containing compound with efficacy against various malignancies. The physico-chemical stability of carboplatin in dextrose 5% water (D5W) has been thoroughly studied; however, there is a paucity of stability data in clinically relevant 0.9% sodium chloride infusion solutions. The manufacturer's limited stability data in sodium chloride solutions hampers the flexibility of carboplatin usage in oncology patients. Hence, the purpose of this study is to determine the physical and chemical stability of carboplatin-sodium chloride intravenous solutions under different storage conditions. The physico-chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL carboplatin-sodium chloride solutions prepared in polyvinyl chloride bags was determined following storage at room temperature under ambient fluorescent light and under refrigeration in the dark. Concentrations of carboplatin were measured at predetermined time points up to seven days using a stability-indicating high-performance liquid chromatography method. All tested solutions were found physically stable for at least seven days. The greatest chemical stability was observed under refrigerated storage conditions. At 4℃, all tested solutions were found chemically stable for at least seven days, with nominal losses of ≤6%. Following storage at room temperature exposed to normal fluorescent light, the chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL solutions was three days, five days, and seven days, respectively. The extended physico-chemical stability of carboplatin prepared in sodium chloride reported herein permits advance preparation of these admixtures, facilitating pharmacy utility and operations. Since no antibacterial preservative is contained within these carboplatin solutions, we recommend storage, when prepared under specified aseptic conditions, no greater than 24 h at room temperature or three days under refrigeration. © The Author(s) 2014.

  4. Chloride ion erosion experiment research in cracked concrete

    Science.gov (United States)

    Ting, Shu; Yang, Li

    2017-08-01

    For the study of chloride ion erosion in cracked concrete, this essay tries to take advantages of relevant trails to build up concrete chloride ion diffusion model based on the Fick’s second law. The parameter of this model is easy to be set, and many factors such as the effect of cracks are taken into consideration in this experiment. The concept of “chloride ion diffusion coefficient of equivalent apparent” is introduced to simplify the calculation. It can help simplify the calculation process, and get a more accurate test result, as well as facilitating the practical application of this parameter.

  5. The mechanism of eccrine sweat pore plugging by aluminium salts using microfluidics combined with small angle X-ray scattering.

    Science.gov (United States)

    Bretagne, Alice; Cotot, Franck; Arnaud-Roux, Mireille; Sztucki, Michael; Cabane, Bernard; Galey, Jean-Baptiste

    2017-05-24

    Aluminium salts are widely used to control sweating for personal hygiene purposes. Their mechanism of action as antiperspirants was previously thought to be a superficial plugging of eccrine sweat pores by the aluminium hydroxide gel. Here we present a microfluidic T junction device that mimics sweat ducts, and is designed for the real time study of interactions between sweat and ACH (Aluminium Chloro Hydrate) under conditions that lead to plug formation. We used this device to image and measure the diffusion of aluminium polycationic species in sweat counter flow. We report the results of small angle X-ray scattering experiments performed to determine the structure and composition of the plug, using BSA (Bovine Serum Albumin) as a model of sweat proteins. Our results show that pore occlusion occurs as a result of the aggregation of sweat proteins by aluminium polycations. Mapping of the device shows that this aggregation is initiated in the T junction at the location where the flow of aluminium polycations joins the flow of BSA. The mechanism involves two stages: (1) a nucleation stage in which aggregates of protein and polycations bind to the wall of the sweat duct and form a tenuous membrane, which extends across the junction; (2) a growth stage in which this membrane collects proteins that are carried by hydrodynamic flow in the sweat channel and polycations that diffuse into this channel. These results could open up perspectives to find new antiperspirant agents with an improved efficacy.

  6. Latherin: a surfactant protein of horse sweat and saliva.

    Directory of Open Access Journals (Sweden)

    Rhona E McDonald

    2009-05-01

    Full Text Available Horses are unusual in producing protein-rich sweat for thermoregulation, a major component of which is latherin, a highly surface-active, non-glycosylated protein. The amino acid sequence of latherin, determined from cDNA analysis, is highly conserved across four geographically dispersed equid species (horse, zebra, onager, ass, and is similar to a family of proteins only found previously in the oral cavity and associated tissues of mammals. Latherin produces a significant reduction in water surface tension at low concentrations (< or = 1 mg ml(-1, and therefore probably acts as a wetting agent to facilitate evaporative cooling through a waterproofed pelt. Neutron reflection experiments indicate that this detergent-like activity is associated with the formation of a dense protein layer, about 10 A thick, at the air-water interface. However, biophysical characterization (circular dichroism, differential scanning calorimetry in solution shows that latherin behaves like a typical globular protein, although with unusual intrinsic fluorescence characteristics, suggesting that significant conformational change or unfolding of the protein is required for assembly of the air-water interfacial layer. RT-PCR screening revealed latherin transcripts in horse skin and salivary gland but in no other tissues. Recombinant latherin produced in bacteria was also found to be the target of IgE antibody from horse-allergic subjects. Equids therefore may have adapted an oral/salivary mucosal protein for two purposes peculiar to their lifestyle, namely their need for rapid and efficient heat dissipation and their specialisation for masticating and processing large quantities of dry food material.

  7. Realistic Facial Expression of Virtual Human Based on Color, Sweat, and Tears Effects

    Directory of Open Access Journals (Sweden)

    Mohammed Hazim Alkawaz

    2014-01-01

    Full Text Available Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry and blushing (anger and happiness is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics.

  8. Realistic facial expression of virtual human based on color, sweat, and tears effects.

    Science.gov (United States)

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics.

  9. Realistic Facial Expression of Virtual Human Based on Color, Sweat, and Tears Effects

    Science.gov (United States)

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics. PMID:25136663

  10. Exercise-induced trace mineral element concentration in regional versus whole-body wash-down sweat.

    Science.gov (United States)

    Baker, Lindsay B; Stofan, John R; Lukaski, Henry C; Horswill, Craig A

    2011-06-01

    Simultaneous whole-body wash-down (WBW) and regional skin surface sweat collections were completed to compare regional patch and WBW sweat calcium (Ca), magnesium (Mg), copper (Cu), manganese (Mn), iron (Fe), and zinc (Zn) concentrations. Athletes (4 men, 4 women) cycled in a plastic open-air chamber for 90 min in the heat. Before exercise, the subjects and cycle ergometer (covered in plastic) were washed with deionized water. After the onset of sweating, sterile patches were attached to the forearm, back, chest, forehead, and thigh and removed on saturation. After exercise, the subjects and cycle ergometer were washed with 5 L of 15-mM ammonium sulfate solution to collect all sweat minerals and determine the volume of unevaporated sweat. Control trials were performed to measure mineral contamination in regional and WBW methods. Because background contamination in the collection system was high for WBW Mn, Fe, and Zn, method comparisons were not made for these minerals. After correction for minimal background contamination, WBW sweat [Ca], [Mg], and [Cu] were 44.6 ± 20.0, 9.8 ± 4.8, and 0.125 ± 0.069 mg/L, respectively, and 5-site regional (weighted for local sweat rate and body surface area) sweat [Ca], [Mg], and [Cu] were 59.0 ± 15.9, 14.5 ± 4.8, and 0.166 ± 0.031 mg/L, respectively. Five-site regional [Ca], [Mg], and [Cu] overestimated WBW by 32%, 48%, and 33%, respectively. No individual regional patch site or 5-site regional was significantly correlated with WBW sweat [Ca] (r = -.21, p = .65), [Mg] (r = .49, p = .33), or [Cu] (r = .17, p = .74). In conclusion, regional sweat [Ca], [Mg], and [Cu] are not accurate surrogates for or significantly correlated with WBW sweat composition.

  11. Chloride migration in concrete with superabsorbent polymers

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange; Jensen, Ole Mejlhede

    2015-01-01

    Superabsorbent polymers (SAP) can be used as a means for internal curing of concrete. In the present study, the development of transport properties of concrete with SAP is investigated. The chloride migration coefficient according to NT BUILD 492 is used as a measure of this. Twenty concrete...... mixtures are tested 7, 14, and 28 days after casting. The development of degree of hydration is followed for 20 corresponding paste mixtures. Both when SAP is added with extra water to compensate the SAP water absorption in fresh concrete and without extra water, the internal curing water held by SAP may...... contribute to increase the degree of hydration. No matter if SAP is added with or without extra water, it appears that the so-called gel space ratio can be used as a key parameter to link age and mixture proportions (water-to-cement ratio and SAP dosage) to the resulting chloride migration coefficient...

  12. Inadvertent injection of potassium chloride instead of sodium chloride during treatment of chronic low back ache with epidural injection leading to paraplegia

    Directory of Open Access Journals (Sweden)

    Rahul Ranjan

    2016-01-01

    Full Text Available Epidural injection of steroid is given for back pain resistant to other conservative management. Normal saline (NS is used as diluent in 80 mg methylprednisolone and a local anesthetic. Due to a similar looking ampoule of NS and potassium chloride (KCl, there is a probability of accidental use of KCl instead of NS. We present a case of a 50 year old male patient having low back ache refractory to other conservative treatments. Epidural injection of steroid was given, but accidently KCl was mixed with methylprednisolone instead of NS. He developed severe cramps in the lower limbs, pruritus, and sweating, and finally paraplegia. Electrocardiography and blood showed features suggestive of hyperkalemia. He was given calcium gluconate and potassium chelating agent along with supportive measures. The patient recovered within 8 h. It is concluded that calcium gluconate and potassium chelating agent can be used if accidentally KCl is injected in epidural space.

  13. Methyltrioctylammonium chloride catalysed sonochemical synthesis ...

    Indian Academy of Sciences (India)

    The greener, clean and efficient protocol for the synthesis of acridine diones derivatives has been achieved by reacting aromatic aldehyde, dimedone and amines using methyltrioctylammonium chloride (Aliquate 336) as a catalyst under ultrasonic irradiations.

  14. Influence of chloride on the chronic toxicity of sodium nitrate to Ceriodaphnia dubia and Hyalella azteca.

    Science.gov (United States)

    Soucek, David J; Dickinson, Amy

    2016-09-01

    While it has been well established that increasing chloride concentration in water reduces the toxicity of nitrite to freshwater species, little work has been done to investigate the effect of chloride on nitrate toxicity. We conducted acute and chronic nitrate (as sodium nitrate) toxicity tests with the cladoceran Ceriodaphnia dubia and the amphipod Hyalella azteca (chronic tests only) over a range of chloride concentrations spanning natural chloride levels found in surface waters representative of watersheds of the Great Lakes Region. Chronic nitrate toxicity test results with both crustaceans were variable, with H. azteca appearing to be one of the more sensitive invertebrate species tested and C. dubia being less sensitive. While the variability in results for H. azteca were to an extent related to chloride concentration in test water that was distinctly not the case for C. dubia. We concluded that the chloride dependent toxicity of nitrate is not universal among freshwater crustaceans. An additional sodium chloride chronic toxicity test with the US Lab strain of H. azteca in the present study suggested that when present as predominantly sodium chloride and with relatively low concentrations of other ions, there is a narrow range of chloride concentrations over which this strain is most fit, and within which toxicity test data are reliable.

  15. Eccrine sweat gland anatomy in cockayne syndrome: a possible diagnostic aid.

    Science.gov (United States)

    Landing, B H; Sugarman, G; Dixon, L G

    1983-01-01

    Cockayne syndrome is an autosomal recessive disease, which includes as major features motor and mental retardation (beginning in the second year), microcephaly, ataxia, retinal degeneration and pigmentation, cataracts, progeroid features, intracranial calcification, hypogonadism, and growth retardation. Many other diseases have some of these features, so that diagnosis of Cockayne syndrome can be difficult, especially in younger children. Eccrine sweat glands were microdissected from autopsy or biopsy specimens from patients with Cockayne syndrome, and mean values for duct length, secretory coil volume, ratio of coil volume to duct length, and axis ratio of the secretory coil were determined. In comparison with values for eccrine glands of patients with no known genetic or chromosomal disease, eccrine glands in Cockayne syndrome are abnormally small for age. Whether other diseases with various similarities to Cockayne syndrome produce similar growth abnormality of eccrine sweat glands is not known, but determination of sweat gland size may provide data suggesting or supporting the diagnosis of Cockayne syndrome.

  16. Hydration, sweat and thermoregulatory responses to professional football training in the heat.

    Science.gov (United States)

    Duffield, Rob; McCall, Allan; Coutts, Aaron James; Peiffer, Jeremiah John

    2012-01-01

    AbstThis study examined the relationship between intensity of training and changes in hydration status, core temperature, sweat rate and composition and fluid balance in professional football players training in the heat. Thirteen professional football players completed three training sessions; "higher-intensity" (140 min; HI140), "lower-intensity" (120 min; LI120) and "game-simulation" (100 min; GS100). Movement demands were measured by Global Positioning System, sweat rate and concentration were determined from dermal patches and body mass change. Despite similar environmental conditions (26.9 ± 0.1 °C and 65.0 ± 7.0% relative humidity [Rh]), higher relative speeds (m · min(-1)) and increased perceptions of effort and thermal strain were observed in HI140 and GS100 compared with LI120 (P sweat rate (L · h(-1)) and electrolyte losses (g) were observed in HI140 and GS100 compared with LI120. Rate of rise in core temperature was correlated with mean speed (r = 0.85), session rating of perceived exertion (sRPE) (r = 0.61), loss of potassium (K+) (r = 0.51) sweat rate (r = 0.49), and total sweat loss (r = 0.53), with mean speed the strongest predictor. Sodium (Na+) (r = 0.39) and K+ (r = 0.50) losses were associated with total distance covered. In hot conditions, individualised rehydration practices should be adopted following football training to account for differences in sweat rate and electrolyte losses in response to intensity and overall activity within a session.

  17. Amino acid composition, including key derivatives of eccrine sweat: potential biomarkers of certain atopic skin conditions.

    Science.gov (United States)

    Mark, Harker; Harding, Clive R

    2013-04-01

    The free amino acid (AA) composition of eccrine sweat is different from other biological fluids, for reasons which are not properly understood. We undertook the detailed analysis of the AA composition of freshly isolated pure human eccrine sweat, including some of the key derivatives of AA metabolism, to better understand the key biological mechanisms governing its composition. Eccrine sweat was collected from the axillae of 12 healthy subjects immediately upon formation. Free AA analysis was performed using an automatic AA analyser after ninhydrin derivatization. Pyrrolidine-5-carboxylic acid (PCA) and urocanic acid (UCA) levels were determined using GC/MS. The free AA composition of sweat was dominated by the presence of serine accounting for just over one-fifth of the total free AA composition. Glycine was the next most abundant followed by PCA, alanine, citrulline and threonine, respectively. The data obtained indicate that the AA content of sweat bears a remarkable similarity to the AA composition of the epidermal protein profilaggrin. This protein is the key source of free AAs and their derivatives that form a major part of the natural moisturizing factor (NMF) within the stratum corneum (SC) and plays a major role in maintaining the barrier integrity of human skin. As perturbations in the production of NMF can lead to abnormal barrier function and can arise as a consequence of filaggrin genotype, we propose the quantification of AAs in sweat may serve as a non-invasive diagnostic biomarker for certain atopic skin conditions, that is, atopic dermatitis (AD). © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  18. Role of Sweat in Accumulation of Orally Administered Griseofulvin in Skin

    Science.gov (United States)

    Shah, Vinod P.; Epstein, William L.; Riegelman, Sidney

    1974-01-01

    Griseofulvin, an orally effective antimicrobial agent, appears in the stratum corneum within 4-8 h after oral administration. Griseofulvin distribution was found to be highest in the outermost layers of the stratum corneum (level I, 20.8±1.5 ng/mg) and lowest inside (level II, 10.0±1.5; level III, 7.5±2.2 ng/mg). In order to study the precise mechanism of griseofulvin transfer to stratum corneum, the role of sweat in the accumulation of griseofulvin was considered. Heat-induced total body sweating decreased the mean stratum corneum concentration of griseofulvin by 55%, and 200-300 ng of griseofulvin accumulated per ml of sweat. A silicone hydrophobic resin was used to differentiate between “wash-off” and carrier properties of sweat for griseofulvin. Prevention of transepidermal water and sweat loss by (a) topical application of formaldehyde-releasing cream to one palm, (b) occlusion by a 2 × 2-cm patch on one arm, and (c) wearing a rubber glove for 24 h, showed a lower griseofulvin concentration when compared to control areas in the same subjects. The results of the gloved hand experiment show that a complete equilibrium is established at all three levels of stratum corneum, thereby removing the reversed gradient. These results support the hypothesis that a “wick effect” is responsible for the observed reversed drug gradient within the stratum corneum. The results of the experiments suggest that sweat and transepidermal fluid loss play an important role in griseofulvin transfer in stratum corneum. PMID:4830229

  19. Silver release from nanocomposite Ag/alginate hydrogels in the presence of chloride ions: experimental results and mathematical modeling

    Science.gov (United States)

    Kostic, Danijela; Vidovic, Srđan; Obradovic, Bojana

    2016-03-01

    A stepwise experimental and mathematical modeling approach was used to assess silver release from nanocomposite Ag/alginate microbeads in wet and dried forms into water and into normal saline solution chosen as a simplified model for certain biological fluids (e.g., blood plasma, wound exudates, sweat, etc). Three phenomena were connected and mathematically described: diffusion of silver nanoparticles (AgNPs) within the alginate hydrogel, AgNP oxidation/dissolution and reaction with chloride ions, and diffusion of the resultant silver-chloride species. Mathematical modeling results agreed well with the experimental data with the AgNP diffusion coefficient estimated as 1.3 × 10-18 m2 s-1, while the first-order kinetic rate constant of AgNP oxidation/dissolution and diffusivity of silver-chloride species were shown to be inversely related. In specific, rapid rehydration and swelling of dry Ag/alginate microbeads induced fast AgNP oxidation/dissolution reaction with Cl- and AgCl precipitation within the microbeads with the lowest diffusivity of silver-chloride species compared to wet microbeads in normal saline. The proposed mathematical model provided an insight into the phenomena related to silver release from nanocomposite Ca-alginate hydrogels relevant for use of antimicrobial devices and established, at the same time, a basis for further in-depth studies of AgNP interactions in hydrogels in the presence of chloride ions.

  20. Highly abundant defense proteins in human sweat as revealed by targeted proteomics and label free quantification mass spectrometry

    Science.gov (United States)

    Csősz, Éva; Emri, Gabriella; Kalló, Gergő; Tsaprailis, George; Tőzsér, József

    2015-01-01

    BACKGROUND The healthy human skin with its effective antimicrobial defense system forms an efficient barrier against invading pathogens. There is evidence suggesting that the composition of this chemical barrier varies between diseases, making the easily-collected sweat an ideal candidate for biomarker discoveries. OBJECTIVE Our aim was to provide information about the normal composition of the sweat, and to study the chemical barrier found at the surface of skin. METHODS Sweat samples from healthy individuals were collected during sauna bathing, and the global protein panel was analyzed by label-free mass spectrometry. SRM-based targeted proteomic methods were designed and stable isotope labeled reference peptides were used for method validation. RESULTS 95 sweat proteins were identified, 20 of them were novel proteins. It was shown that dermcidin is the most abundant sweat protein, and along with apolipoprotein D, clusterin, prolactin inducible protein and serum albumin, they make up 91% of secreted sweat proteins. The roles of these highly abundant proteins were reviewed; all of which have protective functions, highlighting the importance of sweat glands in composing the first line of innate immune defense system, and maintaining the epidermal barrier integrity. CONCLUSION Our findings in regards to the proteins forming the chemical barrier of the skin as determined by label free quantification and targeted proteomics methods are in accordance with previous studies, and can be further used as a starting point for non-invasive sweat biomarker research. PMID:26307449

  1. Dynamic electrochemical measurement of chloride ions

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, Derk B.; Olthuis, Wouter; van den Berg, Albert

    2016-01-01

    This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement,

  2. 21 CFR 184.1426 - Magnesium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... hydrochloric acid solution and crystallizing out magnesium chloride hexahydrate. (b) The ingredient meets the...

  3. 3D bioprinted extracellular matrix mimics facilitate directed differentiation of epithelial progenitors for sweat gland regeneration.

    Science.gov (United States)

    Huang, Sha; Yao, Bin; Xie, Jiangfan; Fu, Xiaobing

    2016-03-01

    Sweat glands perform a vital thermoregulatory function in mammals. Like other skin appendages, they originate from epidermal progenitors. However, they have low regenerative potential in response to injury, and whether adult epidermal progenitors could be specified to differentiate to a sweat gland cell lineage remains largely unexplored. We used bioprinting technology to create a functional in vitro cell-laden 3D extracellular matrix mimics (3D-ECM) with composite hydrogels based on gelatin and sodium alginate because of chemical and structural similarity to ECM components. To achieve specific cell differentiation, mouse plantar dermis and epidermal growth factor were synchronously incorporated into the 3D-ECM mimics to create an inductive niche for epidermal progenitor cells obtained from mice. The biological 3D construct could maintain cell viability, thereby facilitating cell spreading and matrix formation. In vitro data by immunofluorescence and gene expression assay of key cell-surface markers demonstrated that the bioprinted 3D-ECM could effectively create a restrictive niche for epidermal progenitors that ensures unilateral differentiation into sweat gland cells. Furthermore, direct delivery of bioprinted 3D-ECM into burned paws of mice resulted in functional restoration of sweat glands. This study represents the rational design to enhance the specific differentiation of epidermal lineages using 3D bioprinting and may have clinical and translational implications in regenerating sweat glands. Sweat gland regeneration after injury is of clinical importance but remains largely unsolved because of low regenerative potential and lack of a definite niche. Some studies have shown sweat gland regeneration with gene-based interventions or cell-based induction via embryonic components, but translation to clinic is challenging. The novelty and significance of the work lies in the fact that we design a 3D bioprinted extracellular matrix that provides the spatial

  4. Real-time sweat analysis: Concept and development of an autonomous wearable micro-fluidic platform

    OpenAIRE

    Curto, Vincenzo F.; Coyle, Shirley; Byrne, Robert; Diamond, Dermot; Benito-Lopez, Fernando

    2011-01-01

    In this work the development of an autonomous, robust and wearable micro-fluidic platform capable of performing on-line analysis of pH in sweat is discussed. Through the means of an optical detection system based on a surface mount light emitting diode (smLED) and a photodiode as a detector, a wearable system was achieved in which realtime monitoring of sweat pH can be performed during sport activity. We show how through systems engineering, integrating miniaturised electrical com...

  5. The Effect of Varying the Composition of Fingerprint Sweat Deposits on the Corrosion of Brass and Fingerprint Visibility.

    Science.gov (United States)

    Cooper-Dunn, Alice; Jones, Owen; Bond, John W

    2017-09-01

    Corrosion of α-phase brass by sebaceous sweat fingerprint deposits produced identifiable impressions in a majority of samples (n = 40) 4 days after deposition. Combining sebaceous with eccrine sweat yielded a greater percentage of identifiable fingerprint deposits, although this increase was not statistically significant. Production of identifiable fingerprints from eccrine sweat deposits was dependent on the sampling time of year with deposits taken during summer months giving similar percentages of identifiable fingerprints to sebaceous deposits. A statistically significant positive correlation was found between elapsed days after deposition and identifiable eccrine (ρ = 0.787, p sweat deposits was statistically significant compared to winter eccrine deposits (p sweat. © 2017 American Academy of Forensic Sciences.

  6. Normal sweat secretion despite impaired growth hormone-insulin-like growth factor-I axis in obese subjects

    DEFF Research Database (Denmark)

    Rasmussen, M H; Juul, Anders; Main, Katharina M

    2011-01-01

    and after weight loss. Sixteen severely obese women (BMI, 40.6 ± 1.1 kg/m(2)) were investigated before and after a diet-induced weight loss. Sixteen age-matched nonobese women served as controls. The obese subjects presented the characteristic decreased GH release, hyperinsulinaemia, increased FFA levels......, and impaired insulin sensitivity, which all were normalised after diet-induced weight loss of 30 ± 5 kg. Sweat secretion rates were similar comparing obese and nonobese subjects (78 ± 10 versus 82 ± 9 mg/30 minutes) and sweat secretion did not change after a diet-induced weight loss in obese subjects. We......Adults with GH deficiency are known to exhibit reduced sweating. Whether sweating capacity is impacted in obese subjects with impaired GH secretion have not previously been investigated. The main objective was to investigate sweat secretion rate and the GH-IGF-I axis in obese subjects before...

  7. Incidence of cancer among vinyl chloride and polyvinyl chloride workers.

    Science.gov (United States)

    Heldaas, S S; Langård, S L; Andersen, A

    1984-01-01

    The results of a follow up study of the incidence of cancer and the mortality in a cohort of 454 male workers producing vinyl chloride and polyvinyl chloride are presented. The study population was restricted to employees with more than one year's work experience in the study plant between 1950 and 1969 and the cohort was followed up from 1953 to the end of 1979. Twenty three new cases of cancer were observed compared with 20.2 expected; one case of liver angiosarcoma was found. Five cases of lung cancer were found (2.8 expected) and four cases of malignant melanoma of the skin were observed (0.8 expected). The possibility of a causal relationship between exposure to vinyl chloride and the development of malignant melanomas is discussed. PMID:6691932

  8. Determination of silver nanoparticle release from antibacterial fabrics into artificial sweat

    Directory of Open Access Journals (Sweden)

    Kulthong Kornphimol

    2010-04-01

    Full Text Available Abstract Silver nanoparticles have been used in numerous commercial products, including textiles, to prevent bacterial growth. Meanwhile, there is increasing concern that exposure to these nanoparticles may cause potential adverse effects on humans as well as the environment. This study determined the quantity of silver released from commercially claimed nanosilver and laboratory-prepared silver coated fabrics into various formulations of artificial sweat, each made according to AATCC, ISO and EN standards. For each fabric sample, the initial amount of silver and the antibacterial properties against the model Gram-positive (S. aureus and Gram-negative (E. coli bacteria on each fabric was investigated. The results showed that silver was not detected in some commercial fabrics. Furthermore, antibacterial properties of the fabrics varied, ranging from 0% to greater than 99%. After incubation of the fabrics in artificial sweat, silver was released from the different fabrics to varying extents, ranging from 0 mg/kg to about 322 mg/kg of fabric weight. The quantity of silver released from the different fabrics was likely to be dependent on the amount of silver coating, the fabric quality and the artificial sweat formulations including its pH. This study is the unprecedented report on the release of silver nanoparticles from antibacterial fabrics into artificial sweat. This information might be useful to evaluate the potential human risk associated with the use of textiles containing silver nanoparticles.

  9. Sweating rates of dairy cows and beef heifers in hot conditions

    Science.gov (United States)

    Sweating rates from heat-stressed dairy and feedlot cows were measured using a “Portable Calorimeter” and a “Bovine Evaporation Meter” designed and fabricated for the studies reported herein. Measurements were taken when cows were in their natural habitat. The focus of the study was to compare swea...

  10. Cation transport by sweat ducts in primary culture. Ionic mechanism of cholinergically evoked current oscillations

    DEFF Research Database (Denmark)

    Larsen, Erik Hviid; Novak, I; Pedersen, P S

    1990-01-01

    1. The coiled reabsorptive segment of human sweat ducts was cultured in vitro. Cells were then harvested and plated onto a dialysis membrane which was glued over a hole in a small disc. Cultures were maintained in a low serum, hormone-supplemented medium that allowed the cells to grow to confluency...

  11. Sweating Rates of Dairy and Feedlot Cows in Stressful Thermal Environments

    Science.gov (United States)

    Sweating rates from heat-stressed dairy and feedlot cows were measured using a portable calorimeter. Measurements were made when cows were in shade and exposed to direct sunlight (120 to 1100 W/m2) under different air velocities (0.1 to 1.8 m/s). The effect of color of hair coat (black and white) on...

  12. Human communication of emotion via sweat : How specific is it? (abstract)

    NARCIS (Netherlands)

    Smeets, M.A.M.; Toet, A.; Duinkerken, R.; Groot, J. de; Kaldewaij, A.; Hout, M.A. van den; et al

    2011-01-01

    Females evaluate ambiguous facial expression – morphed between happy and fearful – faces as more fearful when exposed to fear sweat as compared to control odor (Zhou & Chen, 2009). We investigated the specificity of this effect, i.e. whether processing of fearful faces is affected specifically by

  13. Morphological study of human sweat ducts for the investigation of THz-wave interaction (Conference Presentation)

    Science.gov (United States)

    Kawase, Kodo; Tripathi, Saroj R.

    2016-03-01

    Recently, some studies reported that the sweat ducts act as a low-Q-factor helical antenna due to their helical structure, and resonate in the terahertz frequency range according to their structural parameters. According to the antenna theory, when the duct works as a helical antenna, the dimension of the helix plays a key role to determine the frequency of resonance. Therefore, the accurate determination of structural parameters of sweat duct is crucially important to obtain the reliable frequency of resonance and modes of operations. Therefore, here we performed the optical coherence tomography (OCT) of human subjects on their palm and foot to investigate the density, distribution and morphological features of sweat ducts. Moreover, we measured the dielectric properties of stratum corneum using terahertz time domain spectroscopy and based upon this information, we determined the frequency of resonance. We recruited 32 subjects for the measurement and the average duct diameter was 95±11μm. Based upon this information on diameter of duct and THz dielectric properties of stratum corneum (ɛ=5.1±1.3), we have calculated the frequency of resonance of sweat duct. Finally, we determined that the center frequency of resonance was 442±76 GHz. We believe that these findings will facilitate further investigation of the THz-skin interaction and provide guidelines for safety levels with respect to human exposure. We will also report on the EEG measurement while being shined by micro watt order THz waves.

  14. Regional and circadian variations of sweating rate and body surface temperature in camels (Camelus dromedarius).

    Science.gov (United States)

    Abdoun, Khalid A; Samara, Emad M; Okab, Aly B; Al-Haidary, Ahmed A

    2012-07-01

    It was the aim of this study to investigate the regional variations in surface temperature and sweating rate and to visualize body thermal windows responsible for the dissipation of excess body heat in dromedary camels. This study was conducted on five dromedary camels with mean body weight of 450 ± 20.5 kg and 2 years of age. Sweating rate, skin and body surface temperature showed significant (P surface temperature measured on seven regions of the camel body did not significantly differ. The variation in body surface temperature compared to the variation in skin temperature was higher in the hump compared to the axillary and flank regions, indicating the significance of camel's fur in protecting the skin from daily variation in ambient temperature. Infrared thermography revealed that flank and axillary regions had lower thermal gradients at higher ambient temperature (T(a) ) and higher thermal gradients at lower T(a) , which might indicate the working of flank and axillary regions as thermal windows dissipating heat during the night. Sweating rate showed moderate correlation to skin and body surface temperatures, which might indicate their working as potential thermal drivers of sweating in camels. © 2012 The Authors. Animal Science Journal © 2012 Japanese Society of Animal Science.

  15. Using the Sweat Lodge Ceremony as Group Therapy for Navajo Youth.

    Science.gov (United States)

    Colmant, Stephen A.; Merta, Rod J.

    1999-01-01

    Describes the sweat lodge ceremony used at a residential treatment center located on the Navajo Nation and compares the ceremony to modern group work identifying Yalom's (1995) 11 therapeutic factors of group therapy within the ceremony. Considers widespread use of the ceremony with Native Americans and nonnative Americans as well as…

  16. Utility of No-Sweat Labels for Apparel Consumers: Profiling Label Users and Predicting Their Purchases.

    Science.gov (United States)

    Dickson, Marsha A.

    2001-01-01

    Responses from 547 of 2,000 consumers indicated consumer support for socially responsible purchasing. For 16%, "No-Sweat" labels indicating the working conditions of apparel makers were a strong purchasing influence. Women, especially unmarried females with lower educational attainment, were most likely to purchase clothing with No-Sweat…

  17. Corrections to the Shapiro Equation used to Predict Sweating and Water Requirements

    Science.gov (United States)

    2008-01-01

    USARIEM TECHNICAL REPORT T07-## CORRECTIONS TO THE SHAPIRO EQUATION USED TO PREDICT SWEATING AND WATER REQUIREMENTS Richard R...daily water requirements based on metabolic rate, climatic conditions, and clothing” as a research priority. Adequate hydration and core temperature...work/rest cycles, water requirements , and maximum endurance times for a given environmental activity and clothing system scenario. The second

  18. The comfort, measured by means of a sweating manikin (WalterTM ...

    African Journals Online (AJOL)

    With the growing importance of clothing comfort in South African and overseas markets for locally produced clothing, the Council for Scientific Industrial Research (CSIR) acquired an advanced sweating fabric manikin for measuring clothing comfort. This preliminary investigation covers the comfort related properties, ...

  19. COGNITIVE AND BEHAVIORAL TREATMENTS OF FEAR OF BLUSHING, SWEATING OR TREMBLING

    NARCIS (Netherlands)

    SCHOLING, A; EMMELKAMP, PMG

    Social phobic patients (n = 30) with fear of blushing, sweating or trembling as the predominant complaint were randomly assigned to three treatment conditions: (1) exposure in vivo followed by cognitive therapy, (2) cognitive therapy followed by exposure in vivo, or (3) a cognitive-behavioural

  20. Determination of silver nanoparticle release from antibacterial fabrics into artificial sweat.

    Science.gov (United States)

    Kulthong, Kornphimol; Srisung, Sujittra; Boonpavanitchakul, Kanittha; Kangwansupamonkon, Wiyong; Maniratanachote, Rawiwan

    2010-04-01

    Silver nanoparticles have been used in numerous commercial products, including textiles, to prevent bacterial growth. Meanwhile, there is increasing concern that exposure to these nanoparticles may cause potential adverse effects on humans as well as the environment. This study determined the quantity of silver released from commercially claimed nanosilver and laboratory-prepared silver coated fabrics into various formulations of artificial sweat, each made according to AATCC, ISO and EN standards. For each fabric sample, the initial amount of silver and the antibacterial properties against the model Gram-positive (S. aureus) and Gram-negative (E. coli) bacteria on each fabric was investigated. The results showed that silver was not detected in some commercial fabrics. Furthermore, antibacterial properties of the fabrics varied, ranging from 0% to greater than 99%. After incubation of the fabrics in artificial sweat, silver was released from the different fabrics to varying extents, ranging from 0 mg/kg to about 322 mg/kg of fabric weight. The quantity of silver released from the different fabrics was likely to be dependent on the amount of silver coating, the fabric quality and the artificial sweat formulations including its pH. This study is the unprecedented report on the release of silver nanoparticles from antibacterial fabrics into artificial sweat. This information might be useful to evaluate the potential human risk associated with the use of textiles containing silver nanoparticles.

  1. Sweating responses and the muscle metaboreflex under mildly hyperthermic conditions in sprinters and distance runners.

    Science.gov (United States)

    Amano, Tatsuro; Ichinose, Masashi; Koga, Shunsaku; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Kondo, Narihiko

    2011-08-01

    To investigate the effects of different training methods on nonthermal sweating during activation of the muscle metaboreflex, we compared sweating responses during postexercise muscle occlusion in endurance runners, sprinters, and untrained men under mild hyperthermia (ambient temperature, 35°C; relative humidity, 50%). Ten endurance runners, nine sprinters, and ten untrained men (maximal oxygen uptakes: 57.5 ± 1.5, 49.3 ± 1.5, and 36.6 ± 1.6 ml·kg(-1)·min(-1), respectively; P sprinters than in untrained men (32.2 ± 4.4 vs. 17.3 ± 2.6 mmHg, respectively; P sprinters and untrained men (0.38 ± 0.07, 0.19 ± 0.03, and 0.11 ± 0.04 mg·cm(-2)·min(-1), respectively; P sprinters and untrained men. Our results suggest that the specificity of training modalities influences the sweating response during activation of the muscle metaboreflex. In addition, these results imply that a greater activation of the muscle metaboreflex does not cause a greater sweating response in sprinters.

  2. In vivo single human sweat gland activity monitoring using coherent anti-Stokes Raman scattering and two-photon excited autofluorescence microscopy.

    Science.gov (United States)

    Chen, X; Gasecka, P; Formanek, F; Galey, J-B; Rigneault, H

    2016-04-01

    Eccrine sweat secretion is of central importance for control of body temperature. Although the incidence of sweat gland dysfunction might appear of minor importance, it can be a real concern for people with either hypohidrosis or hyperhidrosis. However, sweat gland function remains relatively poorly explored. To investigate the function of single human sweat glands. We describe a new approach for noninvasive imaging of single sweat gland activity in human palms in vivo up to a depth of 100 μm, based on nonlinear two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS). These techniques appear to be useful compared with approaches already described for imaging single sweat gland activity, as they allow better three-dimensional spatial resolution of sweat pore inner morphology and real-time monitoring of individual sweat events. By filling the sweat pore with oil and tuning the CARS contrast at 2845 cm(-1) , we imaged the ejection of sweat droplets from a single sweat gland when oil is pushed out by sweat flow. On average, sweat events lasted for about 30 s every 3 min under the conditions studied. On the other hand, about 20% of sweat glands were found inactive. TPEF and CARS were also used to study, at the single pore level, the antiperspirant action of aluminium chlorohydrate (ACH) and to reveal, for the first time in vivo, the formation of a plug at the pore entrance, in agreement with reported ACH antiperspirant mechanisms. Although data were acquired on human palms, these techniques show great promise for a better understanding of sweat secretion physiology and should be helpful to improve the efficacy of antiperspirant formulations. © 2015 British Association of Dermatologists.

  3. Chloride binding of cement-based materials subjected to external chloride environment - A review

    OpenAIRE

    Yuan, Q; Shi, C.; Schutter, G. de; K. Audenaert; Deng, D.

    2009-01-01

    This paper reviews the chloride binding of cement-based materials subjected to external chloride environments. Chloride ion exist either in the pore solution, chemically bound to the hydration products, or physically held to the surface of the hydration products. Chloride binding of cement-based material is very complicated and influenced by many factors, such as chloride concentration, cement composition, hydroxyl concentration, cation of chloride salt, temperature, supplementary cementing m...

  4. Lubiprostone: a chloride channel activator.

    Science.gov (United States)

    Lacy, Brian E; Levy, L Campbell

    2007-04-01

    In January 2006 the Food and Drug Administration approved lubiprostone for the treatment of chronic constipation in men and women aged 18 and over. Lubiprostone is categorized as a prostone, a bicyclic fatty acid metabolite of prostaglandin E1. Lubiprostone activates a specific chloride channel (ClC-2) in the gastrointestinal (GI) tract to enhance intestinal fluid secretion, which increases GI transit and improves symptoms of constipation. This article reviews the role of chloride channels in the GI tract, describes the structure, function, and pharmacokinetics of lubiprostone, and discusses clinically important data on this new medication.

  5. Comparison of sweat loss estimates for women during prolonged high-intensity running.

    Science.gov (United States)

    Cheuvront, Samuel N; Haymes, Emily M; Sawka, Michael N

    2002-08-01

    This study evaluated the error produced by four commonly used field estimates and two prediction equations of total body sweat loss. Eight women distance runners were studied during a 30-km treadmill run (approximately 70% .VO(2max)) in a warm (30 degrees C T(db)) and a cool (14 degrees C T(db)) environment. Total sweat loss (TSL) was determined from changes in body mass corrected for fluid intake (FI), urine losses (UL), clothing (trapped sweat, TS), CO(2)-O(2) exchange (metabolic mass loss, MML), and respiratory water loss (RWL). TSL was compared with four estimates of sweat losses (often employed in the field) from body mass changes corrected for: a) FI only (F-1); b) FI and TS (F-2); c) FI and UL (F-3); or d) FI, TS, and UL (F-4). Two prediction equations were used also for comparison to TSL values. In the warm environment, F-1, F-3, and F-4 accurately estimated (0.2-6.9%; P > 0.05) TSL, whereas F-2 produced a large error (15.3%; P equations markedly underestimated (20-22%) TSL in the warm environment and underestimated (41%) or overestimated (20%) TSL in the cool environment. TSL can be accurately estimated from changes in body mass using F-1, F-3, or F-4 methods in hot environments; however, none of the methods accurately estimated actual TSL values in a cool environment. Neither prediction equation provided accurate estimates of TSL in warm or cool conditions for women runners. These results illustrate the difficulty of accurately estimating and predicting sweat losses in the field.

  6. Leaching from the stratum corneum does not explain the previously reported elevated potassium ion concentration in sweat.

    Science.gov (United States)

    Buono, Michael J; Stone, Michael; Cannon, Daniel T

    2016-03-01

    The purpose of this study was to determine if K+ is leached from the stratum corneum when sweat is present on the skin's surface. The results will help address whether sweat [K+] previously reported in the literature are artifactually elevated as a result of K+ leaching. Twelve (six female, six male) healthy volunteers participated in this study. After thorough skin cleansing and preparation with isopropyl alcohol and high-performance liquid chromatography-grade distilled water, three sites were chosen and a 50 μL drop of artificial sweat was pipetted directly onto the skin. The artificial sweat had a [K+] of 4 mEq·L-1, an osmolality of 120 mosm·L-1, and a pH of 6.0. Immediately following, a clear plastic cover slip (~6 cm2) with a shallow 0.8 cm2 convex impression in the center was applied over each drop, preventing evaporation. Each sample was allowed to sit on the forearm, under the plastic cover slip, for 10 min. The mean (±SD) [K+] in 'artificial' sweat not exposed to the skin was measured to be 4.2±0.4 mEq·L-1. After 10 min of exposure to the stratum corneum of the forearm, the artificial sweat had a mean (±SD) [K+] of 3.9±0.3 mEq·L-1. There was no significant difference (p>0.05) in the [K+] between the control artificial sweat and the samples collected after 10 min of exposure to forearm skin. These results do not support the hypothesis that significant K+ leaching from the stratum corneum into standing sweat is the cause for the previously reported elevated sweat [K+].

  7. Effect of periglandular ionic composition and transport inhibitors on rhesus monkey eccrine sweat gland function in vitro.

    Science.gov (United States)

    Sato, F; Sato, K

    1987-12-01

    1. The effects of peritubular ions and transport inhibitors were studied on methacholine (MCH)-induced sweat secretion by the isolated, cannulated monkey palm sweat glands in vitro and on the transepithelial and basolateral membrane potential (p.d.). 2. Sweat secretory rate was a curvilinear function of peritubular Na+ and Cl- concentration. Among the anion substitutes only Br- was able to totally substitute for Cl-. Presence of HCO3- or H2PO4- in the bath was not essential. 3. Both bumetanide and furosemide inhibited sweat secretion in a dose-dependent manner with the median effective concentration (EC50) of 3 X 10(-6) and 3 X 10(-5) M, respectively. 4. Bumetanide (10(-4) M) had no significant effect on basolateral membrane p.d. but nearly abolished the transepithelial p.d. 5. Hydrochlorothiazide (HCTZ, 3 X 10(-4) M) inhibited sweat secretion by only 35%. Inhibitors of ion exchangers amiloride (10(-4) M) and DIDS (4,4'-diisothiocyanostilbene-2,2'-disulphonic acid, 10(-4) M) lowered sweat secretion by less than 20%. 6. Removal of peritubular K+ as well as addition of 5 mM-Ba2+ also inhibited sweat rate. 5 mM-Ba2+ abolished the transepithelial p.d. and depolarized the basolateral p.d. by 26 mV, although the effects of Ba2+ on sweating and the transepithelial p.d. were only transient. 7. The data raise a possibility that either the NaCl or Na+-K+-2Cl- co-transport system or both may be involved in MCH-induced sweat secretion, whereas the role of parallel ion exchangers, if any, may be rather minor.

  8. Purification of Food-grade Magnesium Chloride

    Directory of Open Access Journals (Sweden)

    Ji Lianmin

    2016-01-01

    Full Text Available The application of the varying weights of bischofite dissolved in the distilled water was investigated. The effects of the temperature on the rate of evaporation and the thermal precipitation time on the purity of the crystal products were fully investigated. Two validation tests including magnifying tests and recycling residue were also studied. Our results demonstrate that the contents of NaCl, KCl and CaSO4in the filtrate reached a minimum value after the pretreatment of 350 g bischofite dissolved in 100 mldistilled water. In the crystal products from the second evaporating stage of the validation tests, the contents of MgCl2·6H2O, SO4 and NaCl+KCl are 99%, ≤0.1±0.01%and ≤0.8±0.04%, respectively. The content of magnesium chloride in the solution was increased to a greater extent, and the impurities reduced correspondingly through thedissolution pretreatments of bischofite. This could decrease energy consumption for the impurity removing stage, evaporation and crystallization process, and thus reduce costs for the industrial production of food-grade magnesium chloride

  9. Accumulation of FDG in axillary sweat glands in hyperhidrosis: a pitfall in whole-body PET examination

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsson, H. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Celsing, F. [Department of Haematology and Infectious Diseases, Karolinska Hospital, Stockholm (Sweden); Ingvar, M. [Department of Cognitive Neurophysiology, Karolinska Hospital, Stockholm (Sweden); Stone-Elander, S. [Department of Cognitive Neurophysiology, Karolinska Hospital, Stockholm (Sweden)]|[Karolinska Pharmacy, Stockholm (Sweden); Larsson, S.A. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden)

    1998-03-27

    A diabetic male with severe autonomic neuropathy and recently discovered Hodgkin`s disease demonstrated bilateral uptake of [2-{sup 18}F]-2-fluoro-2-deoxy-d-glucose (FDG) in the axillary sweat glands during profuse sweating caused by hypoglycaemia at positron emission tomography examination. It is not yet clear whether the sweating interfered with the distribution of the radiopharmaceutical. Regardless of the cause or mechanism for the uptake, the finding is clinically relevant. A bilateral symmetrical accumulation of FDG in the axillae of a tumour patient does not necessarily indicate malignant involvement of the lymph nodes. (orig.) With 1 fig., 9 refs.

  10. Characterizing the transplanar and in-plane water transport properties of fabrics under different sweat rate: Forced Flow Water Transport Tester

    Science.gov (United States)

    Tang, K. P. M.; Chau, K. H.; Kan, C. W.; Fan, J. T.

    2015-11-01

    The water absorption and transport properties of fabrics are critical to wear comfort, especially for sportswear and protective clothing. A new testing apparatus, namely Forced Flow Water Transport Tester (FFWTT), was developed for characterizing the transplanar and in-plane wicking properties of fabrics based on gravimetric and image analysis technique. The uniqueness of this instrument is that the rate of water supply is adjustable to simulate varying sweat rates with reference to the specific end-use conditions ranging from sitting, walking, running to other strenuous activities. This instrument is versatile in terms of the types of fabrics that can be tested. Twenty four types of fabrics with varying constructions and surface finishes were tested. The results showed that FFWTT was highly sensitive and reproducible in differentiating these fabrics and it suggests that water absorption and transport properties of fabrics are sweat rate-dependent. Additionally, two graphic methods were proposed to map the direction of liquid transport and its relation to skin wetness, which provides easy and direct comparison among different fabrics. Correlation analysis showed that FFWTT results have strong correlation with subjective wetness sensation, implying validity and usefulness of the instrument.

  11. Characterizing the transplanar and in-plane water transport properties of fabrics under different sweat rate: Forced Flow Water Transport Tester.

    Science.gov (United States)

    Tang, K P M; Chau, K H; Kan, C W; Fan, J T

    2015-11-23

    The water absorption and transport properties of fabrics are critical to wear comfort, especially for sportswear and protective clothing. A new testing apparatus, namely Forced Flow Water Transport Tester (FFWTT), was developed for characterizing the transplanar and in-plane wicking properties of fabrics based on gravimetric and image analysis technique. The uniqueness of this instrument is that the rate of water supply is adjustable to simulate varying sweat rates with reference to the specific end-use conditions ranging from sitting, walking, running to other strenuous activities. This instrument is versatile in terms of the types of fabrics that can be tested. Twenty four types of fabrics with varying constructions and surface finishes were tested. The results showed that FFWTT was highly sensitive and reproducible in differentiating these fabrics and it suggests that water absorption and transport properties of fabrics are sweat rate-dependent. Additionally, two graphic methods were proposed to map the direction of liquid transport and its relation to skin wetness, which provides easy and direct comparison among different fabrics. Correlation analysis showed that FFWTT results have strong correlation with subjective wetness sensation, implying validity and usefulness of the instrument.

  12. Chloride : The queen of electrolytes?

    NARCIS (Netherlands)

    Berend, Kenrick; van Hulsteijn, Leonard Hendrik; Gans, Rijk O. B.

    Background: Channelopathies, defined as diseases that are caused by mutations in genes encoding ion channels, are associated with a wide variety of symptoms and have been documented extensively over the past decade. In contrast, despite the important role of chloride in serum, textbooks in general

  13. 1,5-Diaminotetrazolium chloride

    Directory of Open Access Journals (Sweden)

    Ling-Qiao Meng

    2010-04-01

    Full Text Available The title compound, CH5N6+·Cl−, crystallized with two indepedent 1,5-diaminotetrazolium cations and two independent chloride anions in the asymmetric unit. In the crystal, there are a number of N—H...Cl hydrogen-bonding interactions, which generate a three-dimensional network.

  14. Methyltrioctylammonium chloride catalysed sonochemical synthesis ...

    Indian Academy of Sciences (India)

    Methyltrioctylammonium chloride catalysed sonochemical synthesis of acridine diones. BHUPINDER KAUR and HARISH KUMAR. ∗. Department of Chemistry, Sant Longowal Institute of Engineering and Technology, Longowal 148 106, India e-mail: choprahk67@gmail.com. MS received 21 May 2012; revised 30 January ...

  15. Disease: H01302 [KEGG MEDICUS

    Lifescience Database Archive (English)

    Full Text Available H01302 Hyperchlorhidrosis isolated (HCHLH) Hyperchlorhidrosis is excessive chloride secretion in sweat.... Abnormal sweat chloride levels is found also in conjunction with various metabolic, en...ic disorder characterized by excessive sweating and increased sweat chloride leve

  16. Chemische contaminanten in diervoeder additief Choline Chloride

    NARCIS (Netherlands)

    Traag, W.A.; Hoogenboom, L.A.P.; Jong, de J.; Egmond, van H.J.; Dam, ten G.

    2010-01-01

    Dit briefrapport beschrijft de resultaten van een onderzoek naar chemische contaminanten in Choline Chloride. De doelstellingen waren: 1) Inzicht te verkrijgen in het voorkomen van (gebromeerde) vlamvertragers en broomdioxines in het diervoederadditief Choline Chloride en het, op basis van de

  17. Microbial reductive dehalogenation of vinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Mannheim, DE; Meshulam-Simon, Galit [Los Angeles, CA; McCarty, Perry L [Stanford, CA

    2014-02-11

    Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.

  18. Microbial reductive dehalogenation of vinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Nannhein, DE; Meshulam-Simon, Galit [Los Altos, CA; McCarty, Perry L [Stanford, CA

    2011-11-22

    Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.

  19. REMOVAL OF CHLORIDE FROM AQUEOUS SOLUTIONS

    Science.gov (United States)

    Schulz, W.W.

    1959-08-01

    The removal of chlorides from aqueons solutions is described. The process involves contacting the aqueous chloride containing solution with a benzene solution about 0.005 M in phenyl mercuric acetate whereby the chloride anions are taken up by the organic phase and separating the organic phase from the aqueous solutions.

  20. 21 CFR 582.5446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Manganese chloride. 582.5446 Section 582.5446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5446 Manganese chloride. (a) Product. Manganese chloride. (b) Conditions of use. This...

  1. 75 FR 33824 - Barium Chloride From China

    Science.gov (United States)

    2010-06-15

    ... COMMISSION Barium Chloride From China Determination On the basis of the record\\1\\ developed in the subject... order on barium chloride from China would be likely to lead to continuation or recurrence of material... Barium Chloride from China: Investigation No. 731-TA-149 (Third Review). By order of the Commission...

  2. Acetylcholine chloride 1% usage for intraoperative cataract surgery miosis

    Directory of Open Access Journals (Sweden)

    Fernando Macei Drudi

    Full Text Available Abstract Objective: To test the efficacy of Acetylcholine chloride use in obtaining intraoperative miosis on phacoemulsification cataract surgery. Methods: Patients with cataract diagnosis and elected for surgical phacoemulsification procedure were selected. All patients underwent conventional phacoemulsification procedure performed by a single surgeon and all patients had 0.2 ml of Acetylcholine chloride 1% irrigated in the anterior chamber at the end of the surgery. The pupillary diameter was measured immediately before the beginning of surgery, immediately before and two minutes after the use of acetylcholine chloride 1%. Results: A total of 30 eyes from 30 patients were included in the study. 18 were female, and mean age was of 69.5 years with a 7.2y standard deviation on the population study. The mean pupillary diameter immediately before the beginning of surgery was 7.5 mm with a standard deviation of 0.56 mm; the mean pupillary diameter immediately before the acetylcholine chloride 1% use (after the intraocular lens im-plantation was 7.1 mm with a standard deviation of 0.57 mm. The mean pupillary diameter two minutes after the use of acetylcholine chloride 1% in the anterior chamber was 3.4 mm with standard deviation of 0.66 mm. The mean maximum action time of ACH chloride 1% was 64 seconds, with a standard deviation of 8 seconds. The mean intraocular pressure on the first postoperative day was 19.1 mmHg with a standard deviation of 2.45 mmHg. Conclusion: We conclude that acetylcholine chloride 1% is an important drug to obtaining intraoperative miosis in cataract surgery.

  3. Effect of spray drying on the properties of amylose-hexadecylammonium chloride inclusion complexes

    Science.gov (United States)

    Water soluble amylose-hexadecyl ammonium chloride complexes were prepared from high amylose corn starch and hexadecyl ammonium chloride by excess steam jet cooking. Amylose inclusion complexes were spray dried to determine the viability of spray drying as a production method. The variables tested in...

  4. Catchment conceptualisation for examining applicability of chloride mass balance method in an area with historical forest clearance

    Directory of Open Access Journals (Sweden)

    H. Guan

    2010-07-01

    Full Text Available Of the various approaches for estimating groundwater recharge, the chloride mass balance (CMB method is one of the most frequently used, especially for arid and semiarid regions. Widespread native vegetation clearance, common in many areas globally, has changed the land surface boundary condition, posing the question as to whether the current system has reached new chloride equilibrium, required for a CMB application. Although a one-dimensional CMB can be applied at a point where the water and chloride fluxes are locally in steady state, the CMB method is usually applied at a catchment scale owing to significant lateral flows in mountains. The applicability of the CMB method to several conceptual catchment types of various chloride equilibrium conditions is examined. The conceptualisation, combined with some local climate conditions, is shown to be useful in assessing whether or not a catchment has reached new chloride equilibrium. The six conceptual catchment types are tested with eleven selected catchments in the Mount Lofty Ranges (MLR, a coastal hilly area in South Australia having experienced widespread historical forest clearance. The results show that six of the eleven catchments match a type VI chloride balance condition (chloride non-equilibrium with a gaining stream, with the ratios of stream chloride output (O over atmospheric chloride input (I, or catchment chloride O/I ratios, ranging from 2 to 4. Two catchments match a type V chloride balance condition (chloride non-equilibrium with a losing stream, with catchment chloride O/I ratios about 0.5. For these type V and type VI catchments, the CMB method is not applicable. The results also suggest that neither a chloride O/I ratio less than one nor a low seasonal fluctuation of streamflow chloride concentration (a factor below 4 guarantees a chloride equilibrium condition in the study area. A large chloride O/I value (above one and a large fluctuation of streamflow chloride

  5. [Routine laboratory tests unnecessary for children referred for recurrent wheezing and/or asthma].

    Science.gov (United States)

    de Vries, T W; Wormmeester, L; van Pinxteren-Nagler, E; Bakker, A J; Brand, P L

    2000-10-28

    To investigate the usefulness of laboratory testing and thorax radiography in children, referred to the paediatrician for evaluation of recurrent wheezing. Retrospective. In this study, 158 children referred for recurrent wheezing to a specialized child outpatient clinic of the Medisch Centrum Leeuwarden, the Netherlands, in the period 1 January 1994-31 December 1996, were evaluated according to a routine protocol including haemoglobin, ESR, leucocytes, immunoglobulins, sweat chloride levels and allergy testing and chest roentgenograms. It was determined whether these investigations had yielded abnormal results and whether these test results aided in confirming/rejecting the diagnosis of asthma or were helpful in clinical management. In 144 of the 158 (91%) children the diagnosis 'asthma' or 'recurrent wheezing' was made. Although numerous test results were abnormal they were not helpful in establishing the diagnosis. In only one child an abnormal chest radiograph was helpful (the radiograph showed infiltrative abnormalities). Tests for aero-allergy were rarely positive in children younger than 2 years; in children older than 6 years aero-allergy was found frequently, notably to dust mite (41/144). The results of this study suggest that--except for allergy testing--routine laboratory testing and chest roentgenograms are not indicated in children referred for evaluation of wheezing disorders. Aero-allergy testing may help to decide on preventive measures.

  6. A comparison of fingerprint sweat corrosion of different alloys of brass.

    Science.gov (United States)

    Sykes, Stephanie; Bond, John W

    2013-01-01

    Fingerprint sweat from 40 donors was deposited onto samples of five α and α + β phase brasses, comprising five alloys with different copper and zinc concentrations, two of which also had the addition of small concentrations of lead. Visual grading of the visibility of the corrosion revealed that brasses with the least amount of zinc produced the most visible and fully formed fingerprints from the most donors. Consideration of previously reported mechanisms for the corrosion of brass suggests red copper (I) oxide as a likely corrosion product for low zinc brasses, and a consideration of the color, composition, and solubility of fingerprint sweat corrosion products suggests that copper (I) oxide produces good contrast and visibility with the brass substrate. Scanning electron microscope images of the corrosion of all five alloys confirmed the enhanced contrast between corroded and uncorroded areas for low zinc alloys. © 2012 American Academy of Forensic Sciences.

  7. Prediction of mean skin temperature for use as a heat strain scale by introducing an equation for sweating efficiency

    Science.gov (United States)

    Kubota, H.; Kuwabara, K.; Hamada, Y.

    2014-09-01

    The present paper made the heat balance equation (HBE) for nude or minimally clad subjects a linear function of mean skin temperature ( t sk) by applying new equations for sweating efficiency ( η sw) and thermoregulatory sweat rate ( S wR). As the solution of the HBE, the equation predicting t sk was derived and used for a heat strain scale of subjects. The η sw was proportional to the reciprocal of S w/ E max ( S w, sweat rate; E max maximum evaporative capacity) and the S wR was proportional to t sk with a parameter of the sweating capacity of the subject. The errors of predicted t sk from observations due to the approximation of η sw were examined based on experimental data conducted on eight young male subjects. The value of errors of t sk was -0.10 ± 0.42 °C (mean ± sample standard deviation (SSD)). We aim to apply the predicted t sk of a subject at a level of sweating capacity as a heat strain scale of a function of four environmental factors (dry- and wet-bulb temperatures, radiation, and air velocity) and three human factors (metabolic rate, sweating capacity, and clothing (≤0.2clo)).

  8. Epidemiological and histopathological analysis of 40 apocrine sweat gland carcinomas in dogs: a retrospective study

    Directory of Open Access Journals (Sweden)

    Kycko Anna

    2016-09-01

    Full Text Available Introduction: Apocrine sweat gland carcinomas (ASGCs are malignant neoplasms of dogs and other animals, rarely reported worldwide. The aim of this study was to summarise the occurrence of this cancer in a population of dogs in Poland between 2009 and 2014 with regards to histological features and body location of the tumours, as well as age, sex and breed of the cancer-affected dogs.

  9. Dissolution of cemented carbide powders in artificial sweat: implications for cobalt sensitization and contact dermatitis.

    Science.gov (United States)

    Stefaniak, Aleksandr B; Harvey, Christopher J; Virji, M Abbas; Day, Gregory A

    2010-10-06

    Skin exposure to cobalt-containing materials can cause systemic immune sensitization and upon repeat contact, elicitation of allergic contact dermatitis (ACD). Data on cobalt dissolution rates are needed to calculate uptake through skin and for development of models to understand risk of sensitization or dermatitis. The purpose of this research was to measure the dissolution kinetics of feedstock and process-sampled powders encountered in the production of hard metal alloys using artificial sweat. The physicochemical properties of each material were characterized prior to evaluation of dissolution behavior. Variations in artificial sweat solvent pH and chemistry were used to understand critical factors in dissolution. Dissolution of cobalt, tungsten, and tungsten carbide was often biphasic with the initial rapid phase being up to three orders of magnitude faster than the latter long-term phase. Artificial sweat pH did not influence dissolution of cobalt or tungsten carbide. Solvent composition had little influence on observed dissolution rates; however, vitamin E suppressed the dissolution of cobalt and tungsten carbide from sintered particles obtained from a chamfer grinder. There was no effect of particle size on dissolution of feedstock cobalt, tungsten, tungsten carbide, and admixture powders. Particle physicochemical properties influenced observed dissolution rates with more cobalt and tungsten carbide dissolving from chamfer grinder particles compared to the feedstock powders or admixture powder. Calculations using the observed dissolution rates revealed that skin exposure concentrations were similar to concentrations known to induce cobalt sensitization and elicit ACD. Observed dissolution rates for cobalt in artificial sweat indicate that dermal uptake may be sufficient to induce cobalt sensitization and allergic dermatitis.

  10. Analisis Brand Equity Pocari Sweat Dalam Persaingan Industri Minuman (Studi Kasus: Mahasiswa Di Bogor)

    OpenAIRE

    Pratama, Fredie; Jono M Munandar

    2010-01-01

    Isotonic drink is a new kind of product in Indonesian consumer goods. This kind of product entered Indonesian market in mid-80s. However, isotonic drink industry is growing up along with the increase of people's welfare and awareness of body health. One of isotonic drinks marketed in Indonesia is Pocari Sweat, produced by PT Amerta Indah Otsuka, which is the market leader in Indonesian isotonic drink industry. High level of competition put more burdens on the producer. PT Amerta has to ensure...

  11. Effects of age on histological parameters of the sweat glands of Nellore cattle

    Directory of Open Access Journals (Sweden)

    Mara Regina Bueno de Mattos Nascimento

    2015-04-01

    Full Text Available The sweat glands are important in thermoregulation of cattle in a warm environment as they help dissipate heat through evaporation. Studies on gland histology are important to define its secretion potential and the capacity of perspiration and heat removal. The objective of this study was to determine, by histomorphometry, glandular epithelium height, the depth of the gland, length of the glandular portion and number of glands per cm2 of the sweat glands of the three age groups of Nellore cattle. Thirty females were used in this study. They were equally divided into calves, heifers and cows. Histological sections were obtained and analyzed by digital images in Trinocular BX40 Olympus microscope coupled to an Oly - 200 camera, connected to a computer. The images were obtained with microscope with 2x, 4x, 10x and 40x magnification objectives. The measurements were performed using HL Image 97 program. The height of glandular epithelium, depth of the glands, length and density of the glandular portion per cm2 , were all analyzed. The calves showed greater height of the glandular epithelium than heifers (P = 0.0024, and cows (P = 0.0191. The depth of the gland was not influenced by age. Cows had higher length of secretory portion than heifers (P = 0.0379 and calves (P = 0.0077. Heifers had a greater number of sweat glands per cm2 of skin than cows (P = 0.023. In cattle, the height of glandular epithelium and the density decreases as animals get older. On the other hand, the length of the secretor portion increases but with no changes in the depth of the sweat glands

  12. Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature

    Science.gov (United States)

    Wyss, C. R.; Brengelmann, G. L.; Johnson, J. M.; Rowell, L. B.; Niederberger, M.

    1974-01-01

    A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.

  13. Electrolytes Test

    Science.gov (United States)

    ... Pregnancy hCG Tumor Marker HDL Cholesterol Heavy Metals Helicobacter pylori Testing Hematocrit Hemoglobin Hemoglobin A1c Hemoglobinopathy Evaluation ... sometimes reported as total CO 2 ). A person's diet provides sodium, potassium, and chloride. The kidneys help ...

  14. Men Smelling Women: Null Effects of Exposure to Ovulatory Sweat on Men's Testosterone

    Directory of Open Access Journals (Sweden)

    James R. Roney

    2012-10-01

    Full Text Available Males of many species, humans included, exhibit rapid testosterone increases after exposure to conspecific females. Female chemical stimuli are sufficient to trigger these responses in many nonhuman species, which raises the possibility of similar effects in humans. Recently, Miller and Maner (2010 reported that smelling T-shirts worn by women near ovulation can trigger testosterone responses in men; however, men were aware that they were smelling women's scents, and thus mental imagery associated with that knowledge may have contributed to the hormone responses. Here, we collected axillary sweat samples from women on days near ovulation. In a crossover design, men who were not explicitly aware of the specific stimuli smelled the sweat samples in one session and water samples in a second session. There were no differences in testosterone responses across the experimental conditions. Our null findings suggest that the relevant chemical signal is not found in axillary sweat, and/or that knowledge of the stimulus source is necessary for hormone responses. These results thus suggest boundary conditions for the effects reported in Miller and Maner (2010, and recommend further research to define the precise circumstances under which men's testosterone may respond to chemosensory cues from women.

  15. Intraparotid Location of the Great Auricular Nerve: A New Anatomical Basis for Gustatory Sweating Syndrome.

    Science.gov (United States)

    Toure, Gaoussou

    2015-11-01

    Gustatory sweating syndrome (also known as Frey syndrome or auriculotemporal nerve syndrome) is thought to result from a lesion of the auriculotemporal nerve. A lesion of this nerve can lead to aberrant regeneration of nerve fibers to the sweat glands and blood vessels. The occurrence of signs outside the region of the auriculotemporal nerve prompted the author to search for another anatomical basis for this syndrome. The author dissected 46 great auricular nerves from their origin to the parotid gland and in the infratemporal fossa. The author investigated the different connections of the great auricular nerve with the facial nerve and the auriculotemporal nerve. The great auricular nerve was found to essentially be a parotid nerve. There was a set of intraparotid nerve connections on 14 of the 46 half-heads that were dissected. The author was able to discern three types of parotid great auricular nerve connections, which he designates as either type 1, connection with the trunk of the facial nerve and its branches; type 2, connection with the auriculotemporal nerve; or type 3, connection with the auriculotemporal nerve and the facial nerve with the formation of an intraparotid nerve circle. Having clearly established the nerve connections of the great auricular nerve, the author believes that it is primarily this nerve that is responsible for gustatory sweating syndrome. This allows for a better understanding of the sympathetic nervous system features and the manifestation of the syndrome outside the region of the auriculotemporal nerve.

  16. Formaldehyde solutions in simulated sweat increase human melanoma but not normal human keratinocyte cells proliferation.

    Science.gov (United States)

    Rizzi, M; Cravello, B; Tonello, S; Renò, F

    2016-12-01

    Our skin is in close contact with clothes most of the time thus risking potentially noxious chemicals contact. One of the potentially harmful manufacturing by-products that can be released by textiles when sweating is formaldehyde, used as an anti-crease treatment. As it is known to be carcinogenic to humans and a potent skin sensitizer, the aim of this study was to investigate its effects on both normal human keratinocytes (HaCaT cells) and on a highly invasive malignant melanoma cell line (SK-MEL-28) in order to contribute to the definition of safety cut-off to be applied to the production processes. Formaldehyde concentrations below the commonly accepted limits (10-50μM) were obtained by diluting formaldehyde in simulated sweat (UNI EN ISO 105-E04). The effects on cell proliferation were evaluated by cell counting, while ERK pathway activation was evaluated by western blot. Low concentrations of formaldehyde (10μM) in both acidic and alkaline simulated sweat were able to increase malignant melanoma cell proliferation, while not affecting normal keratinocytes. Melanoma proliferation increase was greater in acidic (pH=5.5) than in alkaline (pH=8) conditions. Moreover, formaldehyde stimulation was able to induce ERK pathway activation. The data obtained suggest the need for an even increasing attention to the potentially harmful effects of textile manufacturing by-products. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Circular polarization induced by the three-dimensional chiral structure of human sweat ducts.

    Science.gov (United States)

    Hayut, Itai; Ben Ishai, Paul; Agranat, Aharon J; Feldman, Yuri

    2014-04-01

    The upper part of the human eccrine sweat ducts, embedded within the epidermis layer, have a well-defined helical structure. It was recently suggested that, as electromagnetic entities, the sweat ducts interact with sub-mm waves [Y. Feldman et al., Phys. Rev. Lett. 100, 128102 (2008)]. Although correlation between changes in the reflectance spectrum in this frequency range and physiological activities has been shown, a direct link between the electromagnetic reflection and the helical structure itself has remained to be established. The fact that the sweat ducts manifest natural homochirality is henceforth used to produce this link. We report the detection of circular polarization asymmetry in the electromagnetic reflection from the human skin at sub-THz frequencies in vivo. We compare the results to numerical simulations and to measurements of a fabricated metamaterial. We argue that the observed circular dichroism can be interpreted uniquely as the signature of the helical structure itself. By twisting reflected electromagnetic waves, the human skin exhibits properties which are usually discussed only in the framework of metamaterial science.

  18. Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques.

    Science.gov (United States)

    Goulet, Eric D B; Asselin, Audrey; Gosselin, Jonathan; Baker, Lindsay B

    2017-08-01

    Sweat sodium concentration (SSC) can be determined using different analytical techniques (ATs), which may have implications for athletes and scientists. This study compared the SSC measured with 5 ATs: ion chromatography (IChr), flame photometry (FP), direct (DISE) and indirect (IISE) ion-selective electrode, and ion conductivity (IC). Seventy sweat samples collected from 14 athletes were analyzed with 5 instruments: the 883 Basic IC Plus (IChr, reference instrument), AAnalyst 200 (FP), Cobas 6000 (IISE), Sweat-Chek (IC), and B-722 Laqua Twin (DISE). Instruments showed excellent relative (intraclass correlation coefficient (ICC) ≥ 0.999) and absolute (coefficient of variation (CV) ≤ 2.6%) reliability. Relative validity was also excellent between ATs (ICC ≥ 0.961). In regards to the inter-AT absolute validity, compared with IChr, standard error of the estimates were similar among ATs (2.8-3.8 mmol/L), but CV was lowest with DISE (3.9%), intermediate with IISE (7.6%), and FP (6.9%) and highest with IC (12.3%). In conclusion, SSC varies depending on the AT used to analyze samples. Therefore, results obtained from different ATs are scarcely comparable and should not be used interchangeably. Nevertheless, taking into account the normal variability in SSC (∼±12%), the imprecision of the recommendations deriving from FP, IISE, IC, and DISE should have trivial health and physiological consequences under most exercise circumstances.

  19. Textile Functionalization and Its Effects on the Release of Silver Nanoparticles into Artificial Sweat.

    Science.gov (United States)

    Wagener, Sandra; Dommershausen, Nils; Jungnickel, Harald; Laux, Peter; Mitrano, Denise; Nowack, Bernd; Schneider, Gregor; Luch, Andreas

    2016-06-07

    This study addresses the release of total silver (Ag) and silver nanoparticles (Ag-NPs) from textiles into artificial sweat, particularly considering the functionalization technology used in textile finishing. Migration experiments were conducted for four commercially available textiles and for six laboratory-prepared textiles. Two among these lab-prepared textiles represent materials in which Ag-NPs were embedded within the textile fibers (composites), whereas the other lab-prepared textiles contain Ag particles on the respective fiber surfaces (coatings). The results indicate a smaller release of total Ag from composites in comparison to surface-coated textiles. The particulate fraction determined within the artificial sweat was negligible for most textiles, meaning that the majority of the released Ag is present as dissolved Ag. It is also relevant to note that nanotextiles do not release more particulate Ag than conventional Ag textiles. The results rather indicate that the functionalization type is the most important parameter affecting the migration. Furthermore, after measuring different Ag-NP types in their pristine form with inductively coupled plasma mass spectrometry in the single particle mode, there is evidence that particle modifications, like surface coating, may also influence the dissolution behavior of the Ag-NPs in the sweat solutions. These factors are important when discussing the likelihood of consumer exposure.

  20. Prediction of the Chloride Resistance of Concrete Modified with High Calcium Fly Ash Using Machine Learning.

    Science.gov (United States)

    Marks, Michał; Glinicki, Michał A; Gibas, Karolina

    2015-12-11

    The aim of the study was to generate rules for the prediction of the chloride resistance of concrete modified with high calcium fly ash using machine learning methods. The rapid chloride permeability test, according to the Nordtest Method Build 492, was used for determining the chloride ions' penetration in concrete containing high calcium fly ash (HCFA) for partial replacement of Portland cement. The results of the performed tests were used as the training set to generate rules describing the relation between material composition and the chloride resistance. Multiple methods for rule generation were applied and compared. The rules generated by algorithm J48 from the Weka workbench provided the means for adequate classification of plain concretes and concretes modified with high calcium fly ash as materials of good, acceptable or unacceptable resistance to chloride penetration.

  1. Erratum to: Study on Chloride Ion Penetration Resistance of Rubberized Concrete Under Steady State Condition

    Directory of Open Access Journals (Sweden)

    Md Noor Nurazuwa

    2016-01-01

    In this paper, the effect of crumb rubber, CR as fine aggregate in the concrete to enhance concrete durability against chloride ion diffusion was studied. Chloride ion diffusion in rubberized concrete was tested by migration test under steady state condition. Concrete specimen with water-to-cement ratio of 0.50 was prepared to study the CR effectiveness in comparison with lower water-to-cement ratio. In addition, 10% silica fume, SF was added to provide denser concrete and to understand its effectiveness against chloride ion diffusion. Results showed that chloride transport characteristics were improved by the increasing amount of CR in all mixed due to the fact that CR has the ability to repel water. Meanwhile, rubberized concrete with w/c = 0.35 gave better resistance against chloride ion penetration compared to w/c = 0.50. This was much improved with combination of CR and SF.

  2. Wetting properties and critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite.

    Science.gov (United States)

    Bukiet, Frédéric; Couderc, Guillaume; Camps, Jean; Tassery, Hervé; Cuisinier, Frederic; About, Imad; Charrier, Anne; Candoni, Nadine

    2012-11-01

    The purposes of the present study were to (1) assess the effect of the addition of benzalkonium chloride to sodium hypochlorite on its wetting properties, contact angle, and surface energy; (2) determine the critical micellar concentration of benzalkonium chloride in sodium hypochlorite; and (3) investigate the influence of addition of benzalkonium chloride on the free chlorine level, cytotoxicity, and antiseptic properties of the mixture. Solutions of benzalkonium chloride, with concentrations ranging from 0%-1%, were mixed in 2.4% sodium hypochlorite and tested as follows. The wetting properties were investigated by measuring the contact angle of the solutions on a nondehydrated dentin surface by using the static sessile drop method. The pending drop technique was subsequently used to determine the surface energy of the solutions. The critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite was calculated from the data. When 2.4% NaOCl was mixed with benzalkonium chloride at the critical micellar concentration, 3 parameters were tested: free chloride content, cytotoxicity, and antibacterial effects against Enterococcus faecalis. The contact angle (P concentrations. The critical micellar concentration of benzalkonium chloride in sodium hypochlorite was 0.008%. At this concentration, the addition of benzalkonium chloride had no effect on the free chlorine content, cytotoxicity, or antibacterial efficiency of the mixture. The addition of benzalkonium chloride to sodium hypochlorite at the critical micellar concentration reduced the contact angle by 51.2% and the surface energy by 53.4%, without affecting the free chloride content, cytotoxicity, or antibacterial properties of the mixture. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Appearance of D2O in sweat after oral and oral-intravenous rehydration in men.

    Science.gov (United States)

    Emmanuel, Holly; Casa, Douglas J; Beasley, Kathleen N; Lee, Elaine C; McDermott, Brendon P; Yamamoto, Linda M; Armstrong, Lawrence E; Maresh, Carl M

    2011-08-01

    Intravenous (IV) rehydration is common in athletics, but its thermoregulatory benefits and ergogenicity have not been elucidated. Availability of orally ingested fluid is dependent on gastric emptying and intestinal absorption rate. Deuterium oxide (D2O) has been used to demonstrate that fluid ingested during exercise appears in sweat within 10 minutes. The purpose of this study was to determine the effect of concurrent IV rehydration on D2O appearance in sweat samples after per ora rehydration with D2O labeled fluid. We hypothesized that the combination method would not be superior to the oral method. Ten fit men (age 23 ± 4, VO2max 59.49 ± 4.09 L·min(-1)) underwent 20 hours of fluid restriction resulting in 1.95 ± 0.25% body weight loss before beginning treadmill exercise and cycling. Exercise was performed in an environmental chamber (35.6 ± 0.2° C, 35.0 ± 1.8% relative humidity) for 2 hours at 55% VO2max, and the participants exhibited a mean body weight deficit of 4.50 ± 0.04%. Thermoregulatory measures were recorded while subjects were rehydrated with oral (OR) or oral combined with intravenous (IVO) fluid traced with D2O. After 30 minutes of rehydration and 30 minutes of seated recovery, the subjects began treadmill exercise at 55-60% VO2max. Forehead sweat samples were collected 0, 5, 10, 20, and 75 minutes from the start of rehydration. The samples were analyzed for D2O via isotope ratio mass spectrometry. D2O did not appear in the sweat within 20 minutes of rehydration; however, it did appear during the subsequent exercise bout. There was no significant difference between rehydration modes. Plasma volume increases and decreased volume of orally ingested fluid did not significantly alter transit time from ingestion to appearance in excreted sweat. The IVO method does not appear to be superior to the traditional OR method of rehydration.

  4. Potential Analysis of Thunderstorm Occurrence Using SWEAT Method at Meteorology Station Sultan Iskandar Muda

    Directory of Open Access Journals (Sweden)

    Ulfah Kurnia

    2018-01-01

    Full Text Available Salah satu hal penting dalam mengutamakan keselamatan penerbangan ialah informasi meteorologi yang tepat dan akurat terutama mengenai kondisi cuaca buruk seperti thunderstorm. Oleh karena itu, perlu dilakukan prakiraan potensi terjadinya thunderstorm, sehingga pihak maskapai penerbangan dapat menyesuaikan prosedur keselamatan baik pada saat take off, on the route, maupun landing. Pada penelitian ini dilakukan analisis data radiosonde pada 2 (dua musim, yaitu musim kemarau dan musim hujan untuk memprakirakan potensi terjadinya thunderstorm selama periode April-Desember 2016 dan Januari-Maret 2017. Data radiosonde tersebut diperoleh dari Stasiun Meteorologi Sultan Iskandar Muda yang telah diukur setiap dua kali dalam satu hari. Waktu pengukurannya ialah pada pukul 00Z dan pukul 12Z. Dengan menggunakan Software Rawinsonde Observation (RAOB versi 5.7, dilakukan pengolahan data radiosonde sehingga diperoleh informasi parameter atmosfer seperti temperatur, titik embun, dan kecepatan angin. Parameter atmosfer tersebut dapat digunakan untuk memprakirakan potensi terjadinya thunderstorm selama dua belas jam kedepan, yaitu dengan menggunakan metode SWEAT (Severe Weather Threat sehingga diperoleh SWEAT Indeks untuk setiap pengukuran radiosonde. Berdasarkan penelitian yang telah dilakukan, diketahui SWEAT Indeks untuk wilayah Stasiun Meteorologi Sultan Iskandar Muda berkisar antara 39,8 - 355,4. Hasil analisis metode SWEAT diverifikasi dengan data aktual (data synop yang diamati di Stasiun Meteorologi Sultan Iskandar Muda dan diketahui persentase kesesuaian antara data prakiraan dengan kondisi aktual yaitu 58,62-66,67%.   One of the most important things in aviation safety is the accurate information of meteorology especially on bad weather conditions as thunderstorm. Therefore, need to forecast about potential occurrence of thunderstorm, so the airlines can adjust safety aviation when take of, an the route, and landing. In this research was analysis of

  5. Tick resistance and heat tolerance characteristics in cattle. III. Sweating rate

    Directory of Open Access Journals (Sweden)

    Cecília José Veríssimo

    2012-12-01

    Full Text Available Cattle in a sustainable tropical livestock should be heat tolerant and resistant to ticks. The relationship between Rhipicephalus (Boophilus microplus infestation and sweating rate, an important heat tolerance characteristic, was studied in six Nellore and four Holstein steers of seven-month-old. They were artificial infested (a.i. with 10,000 (Holstein and 20,000 (Nellore larvae in 16/Apr/2011. In days 20, 23 and 24 after the infestation, the 10 bigger females ticks found in whole animal were weighed and put in a chamber (27 oC and 80% RH, weighing the egg mass of each female tick fourteen days after. The sweating rate (SRskin, measured by Scheleger and Turner, 1963, method, in a shaved area of shoulder skin was evaluated in 14/Apr (2 days before the a.i. and in 05/May (19 days after a.i.. In 14/Apr the Scheleger and Turner, 1963, method was done on the coat not shaved (SRcoat. The sweating rate was measured in the afternoon (from 2 P.M., after 30 minutes of direct sunlight, on April. On May, the animals remained 60 minutes in direct sunlight because this day was colder. The experimental design was a non-probability sample restricted to the 10 available animals. Data from the steers’ sweating rate were analyzed using the General linear models of the SPSS® statistical package (version 12.0 using SRskin as dependent variable and breed and sampling date as independent variables. For SRcoat breed was the independent variable. Nellore, a tropical cattle breed, had higher SRskin (1,000.82 ± 64.59 g m-2 h-1, P< 0.001 than Holstein (620.45 ± 79.10 g m-2 h-1. SRskin was higher on May (1,187.33 ± 71.49 g m-2 h-1, P< 0.001 than on April (433.93 ± 71.49 g m-2 h-1. The correlation between the two different measurements of SR was positive and significant (r= 0,545, P<0,01, Pearson correlation. But in SRcoat the breed effect disappeared because the Holstein SRcoat increased (Holstein: 884.95 ± 472.12 g m-2 h-1 and Nellore: 1,060.72 ± 318.21 g m-2 h-1

  6. Partial replacement of sodium chloride in Italian salami and the influence on the sensory properties and texture

    Directory of Open Access Journals (Sweden)

    Claudia Fieira

    2015-05-01

    Full Text Available Cured meat products, such as Italian salami, exhibit high levels of sodium from NaCl, added to ensure flavor and texture. Studies indicates a close relationship between the consumption of these products and hypertension and cardiovascular diseases. The objective of this study was to evaluate the effect of partial replacement of sodium chloride by potassium chloride, magnesium chloride, and calcium chloride on the texture and sensory attributes of Italian salami and to quantify the levels of minerals in the finished product. Four formulations were prepared: without a starter culture (F1; with a starter culture (F2; partial replacement of 60% sodium chloride by  potassium chloride (F3; and partial replacement of sodium chloride by a mixture containing potassium chloride,  magnesium chloride, and calcium chloride (F4. Analyses of Na+, K+, Ca+2 and Mg+2 contents, texture profile and sensory attributes (acceptance test were carried out. Formulations F1, F2, F3 and F4 presented levels of Na+ 0.53, 0.44, 0.36 and 0.30, respectively. The formulations presented a reduction in the sodium chloride content over 25%, thus complying with the requirements of the current legislation. The addition of these salts affected certain important sensory attributes, such as flavor and global impression, and increased hardness and chewiness values.

  7. Sex differences in amino acids lost via sweating could lead to differential susceptibilities to disturbances in nitrogen balance and collagen turnover.

    Science.gov (United States)

    Dunstan, R H; Sparkes, D L; Dascombe, B J; Stevens, C J; Murphy, G R; Macdonald, M M; Gottfries, J; Gottfries, C-G; Roberts, T K

    2017-08-01

    Fluid collected during sweating is enriched with amino acids derived from the skin's natural moisturising factors and has been termed "faux" sweat. Little is known about sex differences in sweat amino acid composition or whether faux sweat amino acid losses affect nitrogen balance. Faux sweat collected by healthy adults (n = 47) after exercise, and at rest by chronic fatigue patients, was analysed for amino acid composition. Healthy females had higher total amino acid concentrations in sweat (10.5 ± 1.2 mM) compared with healthy males (6.9 ± 0.9 mM). Females had higher levels of 13 amino acids in sweat including serine, alanine and glycine. Higher hydroxyproline and proline levels suggested greater collagen turnover in females. Modelling indicated that with conservative levels of exercise, amino acid losses in females via faux sweat were triple than those predicted for urine, whereas in males they were double. It was concluded that females were more susceptible to key amino acid loss during exercise and/or hot conditions. Females reporting chronic fatigue had higher levels of methionine in faux sweat than healthy females. Males reporting chronic fatigue had higher levels of numerous amino acids in faux sweat compared to healthy males. Higher amino acid loss in faux sweat associated with chronic fatigue could contribute to a hypometabolic state. Depending on activity levels, climatic conditions and gender, amino acid losses in sweat and skin leachate could influence daily protein turnover where periods of continuously high turnover could lead to a negative net nitrogen balance.

  8. A Simplified Extemporaneously Prepared Potassium Chloride Oral Solution.

    Science.gov (United States)

    Tannous, Elias; Tal, Yana; Amarny, Kamal

    2016-01-01

    Although commercial preparations of oral potassium supplements are usually available, there are times when our Medical Center is faced with situations in which the oral solution of potassium chloride is not available. This solution is necessary for our pediatric outpatients who cannot swallow tablets and need an oral solution. Moreover, there are no studies available which describe an extemporaneously prepared potassium chloride oral solution on which we can rely for assigning a beyond-use date. The aim of this study was to formulate an extemporaneous pediatric oral solution of potassium chloride and to determine the physical and chemical stability of this preparation. We prepared 1 mMoL/mL by withdrawing 25 mL of potassium chloride 14.9%. Ora-Sweet SF was added to 50 mL in a metered flask. The solution was kept refrigerated (2°C to 8°C). Samples were withdrawn to measure potassium concentration, pH, and microbial overgrowth. The test was performed by our biochemical laboratory. The oral solution of potassium chloride 1 mMoL/mL stored at 2°C to 8°C maintained at least 91% of the initial concentration for 28 days. There were no notable changes in pH, and the solution remained physically stable with no visual microbial growth. The oral solution of potassium chloride 1 mMoL/mL prepared in Ora-Sweet and stored at 2°C to 8°C in amber glass bottles is expected to remain stable for 28 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  9. Rectal temperature, distal sweat rate, and forearm blood flow following mild exercise at two phases of the circadian cycle.

    Science.gov (United States)

    Waterhouse, Jim; Aizawa, Seika; Nevill, Alan; Edwards, Benjamin; Weinert, Dietmar; Atkinson, Greg; Reilly, Thomas

    2007-01-01

    Changes in rectal temperature during mild exercise in the middle of the rising (11:00 h) and falling (23:00 h) phases of the circadian rhythm of resting core temperature have been compared. Seven healthy males were studied at rest, while exercising on a cycle ergometer (60 min at 80 W), and during the first 30 min of recovery. Rectal temperature, forearm blood flow, and forearm sweat rate were measured at 1 min intervals throughout. During exercise, there were significant time-of-day differences in the profiles of all three variables, and in the thresholds for increases in forearm blood flow and sweating. Forearm blood flow and sweat rate were recruited more rapidly and to a greater extent with evening exercise, and rectal temperature rose less. Analysis of covariance, with rectal temperature as the covariate, indicated the associations between it and forearm blood flow or sweating were significantly different (ptimes of day. There were also significant (ptime-of-day effects for forearm blood flow and sweating that were independent of rectal temperature. During recovery, rectal temperature fell more quickly in the late evening than late morning. Forearm blood flow and sweating also showed time-of-day differences, but these did not co-vary with rectal temperature. Control of rectal temperature during exercise and recovery appears to be more effective in the late evening than late morning, and differences in forearm blood flow and sweating, as well as factors independent of these two variables, contribute to this difference. The results support our "heat-gain/heat-loss modes" hypothesis.

  10. 4-(Methylsulfonylpiperazin-1-ium chloride

    Directory of Open Access Journals (Sweden)

    Hoong-Kun Fun

    2010-02-01

    Full Text Available In the title molecular salt, C5H13N2O2S+·Cl−, the complete cation is generated by crystallographic mirror symmetry, with both N atoms, the S atom and one C atom lying on the reflecting plane. The chloride ion also lies on the mirror plane. The piperazinium ring adopts a chair conformation and the N—S bond adopts an equatorial orientation. In the crystal structure, the component ions are linked into a three-dimensional framework by intermolecular N—H...Cl and C—H...Cl hydrogen bonds.

  11. 21 CFR 184.1446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Manganese chloride. 184.1446 Section 184.1446 Food... Specific Substances Affirmed as GRAS § 184.1446 Manganese chloride. (a) Manganese chloride (MnCl2·4H2O, CAS Reg. No. 7773-01-5) is a pink, translucent, crystalline product. It is also known as manganese...

  12. 21 CFR 184.1138 - Ammonium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ammonium chloride. 184.1138 Section 184.1138 Food... Specific Substances Affirmed as GRAS § 184.1138 Ammonium chloride. (a) Ammonium chloride (NH4Cl, CAS Reg..._locations.html. (c) In accordance with § 184.1(b)(1), the ingredient is used in food with no limitation...

  13. Prediction of Chloride Penetration into Hardening Concrete

    OpenAIRE

    Wei-Jie Fan; Xiao-Yong Wang

    2015-01-01

    In marine and coastal environments, penetration of chloride ions is one of the main mechanisms causing concrete reinforcement corrosion. Currently, most of experimental investigations about submerged penetration of chloride ions are started after the four-week standard curing of concrete. The further hydration of cement and reduction of chloride diffusivity during submerged penetration period are ignored. To overcome this weak point, this paper presents a numerical procedure to analyze simult...

  14. Jewellery: alloy composition and release of nickel, cobalt and lead assessed with the EU synthetic sweat method.

    Science.gov (United States)

    Hamann, Dathan; Thyssen, Jacob P; Hamann, Carsten R; Hamann, Curtis; Menné, Torkil; Johansen, Jeanne D; Spiewak, Radoslaw; Maibach, Howard; Lundgren, Lennart; Lidén, Carola

    2015-10-01

    Several studies have shown nickel and cobalt release from jewellery by using spot tests, but the metal composition of jewellery is largely unknown. To evaluate the metal composition of a large worldwide sample of mainly inexpensive jewellery items, and investigate the release of nickel, cobalt and lead from a subsample by using EN 1811:1998-required methods. A total of 956 metallic jewellery components were examined with X-ray fluorescence spectroscopy. A subsample of 96 jewellery items purchased in the United States were investigated for nickel, cobalt and lead release by the use of artificial sweat immersion and plasma optical emission spectroscopy. Eighteen elements were detected. The 10 most frequently occurring were, in order of frequency, copper, iron, zinc, nickel, silver, chromium, tin, manganese, lead, and cobalt. Release of nickel was noted from 79 of the 96 US samples (0.01-98 µg/cm(2) /week), release of cobalt from 35 samples (0.02-0.5 µg/cm(2) /week), and release of lead from 37 samples (0.03-2718 µg/cm(2) /week). We present here a comprehensive list of the most frequently encountered metals in jewellery and fashion accessories. Different allergenic and non-allergenic metals are utilized. We also report the frequent release of nickel, cobalt and lead from these objects, despite legislative restrictions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Silver release from nanocomposite Ag/alginate hydrogels in the presence of chloride ions: experimental results and mathematical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kostic, Danijela, E-mail: dkostic@tmf.bg.ac.rs [Innovation Center of the Faculty of Technology and Metallurgy (Serbia); Vidovic, Srđan, E-mail: srdjanhi@gmail.com; Obradovic, Bojana, E-mail: bojana@tmf.bg.ac.rs [University of Belgrade, Faculty of Technology and Metallurgy (Serbia)

    2016-03-15

    A stepwise experimental and mathematical modeling approach was used to assess silver release from nanocomposite Ag/alginate microbeads in wet and dried forms into water and into normal saline solution chosen as a simplified model for certain biological fluids (e.g., blood plasma, wound exudates, sweat, etc). Three phenomena were connected and mathematically described: diffusion of silver nanoparticles (AgNPs) within the alginate hydrogel, AgNP oxidation/dissolution and reaction with chloride ions, and diffusion of the resultant silver-chloride species. Mathematical modeling results agreed well with the experimental data with the AgNP diffusion coefficient estimated as 1.3 × 10{sup −18} m{sup 2} s{sup −1}, while the first-order kinetic rate constant of AgNP oxidation/dissolution and diffusivity of silver-chloride species were shown to be inversely related. In specific, rapid rehydration and swelling of dry Ag/alginate microbeads induced fast AgNP oxidation/dissolution reaction with Cl{sup −} and AgCl precipitation within the microbeads with the lowest diffusivity of silver-chloride species compared to wet microbeads in normal saline. The proposed mathematical model provided an insight into the phenomena related to silver release from nanocomposite Ca-alginate hydrogels relevant for use of antimicrobial devices and established, at the same time, a basis for further in-depth studies of AgNP interactions in hydrogels in the presence of chloride ions.

  16. Experiment on Chloride Ion Content of Concrete Structure in Coastal Salt-fog Area

    Directory of Open Access Journals (Sweden)

    Nie Ming

    2016-01-01

    Full Text Available This paper chose the south-east coastal salt-fog area Shantou to carry out the experiment study on chloride ion content of concrete structure, through the chloride ion content field test on reinforced concrete structure in Shantou, respectively for the slat-fog atmosphere zone and the splash zone in marine environment, discuss the corrosion by chloride ion of long-time existing concrete structure.And then measure the chloride ion content of concrete cover in different depth, and determine the chloride ion diffusion model in different conditions concrete through comparative analysis.The result of study, can be used in directing the selection of design scheme for building in planning, and also it will help predict the corrosion time of reinforcement inside the concrete on different positions for existing structure.

  17. Chloride stress corrosion cracking of Alloy 600 in boric acid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Berge, Ph. [Electricite de France, 92 - Paris la Defense (France); Noel, D.; Gras, J.M.; Prieux, B. [Electricite de France, 77 - Moret-sur-Loing (France). Direction des Etudes et Recherches

    1997-10-01

    The high nickel austenitic alloys are generally considered to have good resistance to chloride stress corrosion cracking. In the standard boiling magnesium chloride solution tests, alloys with more than 40% nickel are immune. Nevertheless, more recent data show that cracking can occur in both Alloys 600 and 690 if the solution is acidified. In other low pH media, such as boric acid solution at 100 deg C, transgranular and intergranular cracking are observed in Alloy 600 in the presence of minor concentrations of sodium chloride (2g/I). In concentrated boric acid at higher temperatures (250 and 290 deg C), intergranular cracking also occurs, either when the chloride concentration is high, or at low chloride contents and high oxygen levels. The role of pH and a possible specific action of boric acid are discussed, together with the influence of electrochemical potential. (author) 21 refs.

  18. ENVIRONMENTAL EXPOSURE TO VINYL CHLORIDE

    Directory of Open Access Journals (Sweden)

    Henryka Langauer-Lewowicka

    2010-09-01

    Full Text Available Vinyl chloride (VC monomer is a wellknown carcinogenic and mutagenic substance causes liver damages, angiosarcoma of the liver, acro – osteolysis, sclerodermalike changes in workers chronically exposed to this gas. There are following VC emitors to the environment: VC production plants, polymerization facilities and planes where polyvinyl products are fabricated. Because of that, the general population is coming into VC contact through polluted air, food and water. VC concentration in all mentioned sites is very low, often not detectable. There was found any health risk for the general population. The VC air concentration in the vicinity to antropogenic emitors is always higher. Such a situation may causes undesirable health effect for residents living in the neighbourhood. Epidemiological studies are performed to detect the adverse VC effect in selected cohorts. Non of the study did not confirmed cases of angiosarcoma among residents living near a vinyl chloride sites. VC production is growing permanently, so VC emission will be higher. Because of that health monitoring of general population and especially of selected groups seems to be necessary in the future.

  19. Evaluation Technique of Chloride Penetration Using Apparent Diffusion Coefficient and Neural Network Algorithm

    Directory of Open Access Journals (Sweden)

    Yun-Yong Kim

    2014-01-01

    Full Text Available Diffusion coefficient from chloride migration test is currently used; however this cannot provide a conventional solution like total chloride contents since it depicts only ion migration velocity in electrical field. This paper proposes a simple analysis technique for chloride behavior using apparent diffusion coefficient from neural network algorithm with time-dependent diffusion phenomena. For this work, thirty mix proportions of high performance concrete are prepared and their diffusion coefficients are obtained after long term-NaCl submerged test. Considering time-dependent diffusion coefficient based on Fick’s 2nd Law and NNA (neural network algorithm, analysis technique for chloride penetration is proposed. The applicability of the proposed technique is verified through the results from accelerated test, long term submerged test, and field investigation results.

  20. Morphology of human sweat ducts observed by optical coherence tomography and their frequency of resonance in the terahertz frequency region

    Science.gov (United States)

    Tripathi, Saroj R.; Miyata, Eisuke; Ishai, Paul Ben; Kawase, Kodo

    2015-03-01

    It is crucial to understand the various biological effects induced by terahertz (THz) electromagnetic waves with the rapid development of electronic and photonic devices operating in the THz frequency region. The presence of sweat glands plays an important role in THz wave interactions with human skin. We investigated the morphological features of sweat ducts using optical coherence tomography (OCT) to further understand such phenomena. We observed remarkable features of the ducts, such as their clear helical structure. The intersubject and intrasubject variations in the diameter of sweat ducts were considerably smaller than the variations in other structural parameters, such as length and number of turns. Based on the sweat duct dimensions and THz dielectric properties of skin measured using terahertz time-domain spectroscopy (THz-TDS), we calculated the resonating frequency of the sweat duct under the assumption of it functioning as a helical antenna. Here, we show that the resonance frequency in the axial mode of operation lies in the THz wave region with a centre frequency of 0.44 +/- 0.07 THz. We expect that these findings will further our understanding of the various health consequences of the interaction of THz waves with human beings.

  1. 2nd dimensional GC-MS analysis of sweat volatile organic compounds prepared by solid phase micro-extraction.

    Science.gov (United States)

    Choi, Mi-Jung; Oh, Chang-Hwan

    2014-01-01

    The characteristics of an individual's odor from sweat, breath and skin provide important information for criminal tracking in field of forensic science. Solid phase micro-extraction gas chromatography/mass spectrometry (SPME-GC/MS) was used to determine human sweat volatile organic compounds (VOCs) profiles. The mass spectrometric analysis (with electron impact mode) followed by 2nd dimensional separation with two different GC columns (one polar and one relatively nonpolar) connected in parallel were used to identify the 574 compounds from sweat samples. The components included alcohols, aldehydes, aliphatics/aromatics, carboxylic acids, esters, ketones, and other organic compounds (amides/amines, thio/thioesters, oxide, sulfides, nitro compounds). Of these compounds, 1-tridecanol, 1,3-bis(1,1-dimethyl ethyl)-benzene, 4,4'-(1-methylethylidene) bis-phenol and 7-acetyl-6-ethyl-1,1,4,4,-tetramethyl-tetraline were common components in all donor's sweat volatile samples. Age-related specific compounds were also detected. The results suggest that characteristic volatile profiles of human sweat emanations could provide the valuable information to forensic scientists.

  2. Resistance of Alkali-Activated Slag Concrete to Chloride-Induced Corrosion

    Directory of Open Access Journals (Sweden)

    Joon Woo Park

    2015-01-01

    Full Text Available The corrosion resistance of steel in alkali-activated slag (AAS mortar was evaluated by a monitoring of the galvanic current and half-cell potential with time against a chloride-contaminated environment. For chloride transport, rapid chloride penetration test was performed, and chloride binding capacity of AAS was evaluated at a given chloride. The mortar/paste specimens were manufactured with ground granulated blast-furnace slag, instead of Portland cement, and alkali activators were added in mixing water, including Ca(OH2, KOH and NaOH, to activate hydration process. As a result, it was found that the corrosion behavior was strongly dependent on the type of alkali activator: the AAS containing the Ca(OH2 activator was the most passive in monitoring of the galvanic corrosion and half-cell potential, while KOH, and NaOH activators indicated a similar level of corrosion to Portland cement mortar (control. Despite a lower binding of chloride ions in the paste, the AAS had quite a higher resistance to chloride transport in rapid chloride penetration, presumably due to the lower level of capillary pores, which was ensured by the pore distribution of AAS mortar in mercury intrusion porosimetry.

  3. Luteal phase of the menstrual cycle increases sweating rate during exercise

    Directory of Open Access Journals (Sweden)

    Garcia A.M.C.

    2006-01-01

    Full Text Available The present study evaluated whether the luteal phase elevation of body temperature would be offset during exercise by increased sweating, when women are normally hydrated. Eleven women performed 60 min of cycling exercise at 60% of their maximal work load at 32ºC and 80% relative air humidity. Each subject participated in two identical experimental sessions: one during the follicular phase (between days 5 and 8 and the other during the luteal phase (between days 22 and 25. Women with serum progesterone >3 ng/mL, in the luteal phase were classified as group 1 (N = 4, whereas the others were classified as group 2 (N = 7. Post-exercise urine volume (213 ± 80 vs 309 ± 113 mL and specific urine gravity (1.008 ± 0.003 vs 1.006 ± 0.002 changed (P < 0.05 during the luteal phase compared to the follicular phase in group 1. No menstrual cycle dependence was observed for these parameters in group 2. Sweat rate was higher (P < 0.05 in the luteal (3.10 ± 0.81 g m-2 min-1 than in the follicular phase (2.80 ± 0.64 g m-2 min-1 only in group 1. During exercise, no differences related to menstrual cycle phases were seen in rectal temperature, heart rate, rate of perceived exertion, mean skin temperature, and pre- and post-exercise body weight. Women exercising in a warm and humid environment with water intake seem to be able to adapt to the luteal phase increase of basal body temperature through reduced urinary volume and increased sweating rate.

  4. Luteal phase of the menstrual cycle increases sweating rate during exercise

    Directory of Open Access Journals (Sweden)

    A.M.C. Garcia

    Full Text Available The present study evaluated whether the luteal phase elevation of body temperature would be offset during exercise by increased sweating, when women are normally hydrated. Eleven women performed 60 min of cycling exercise at 60% of their maximal work load at 32ºC and 80% relative air humidity. Each subject participated in two identical experimental sessions: one during the follicular phase (between days 5 and 8 and the other during the luteal phase (between days 22 and 25. Women with serum progesterone >3 ng/mL, in the luteal phase were classified as group 1 (N = 4, whereas the others were classified as group 2 (N = 7. Post-exercise urine volume (213 ± 80 vs 309 ± 113 mL and specific urine gravity (1.008 ± 0.003 vs 1.006 ± 0.002 changed (P < 0.05 during the luteal phase compared to the follicular phase in group 1. No menstrual cycle dependence was observed for these parameters in group 2. Sweat rate was higher (P < 0.05 in the luteal (3.10 ± 0.81 g m-2 min-1 than in the follicular phase (2.80 ± 0.64 g m-2 min-1 only in group 1. During exercise, no differences related to menstrual cycle phases were seen in rectal temperature, heart rate, rate of perceived exertion, mean skin temperature, and pre- and post-exercise body weight. Women exercising in a warm and humid environment with water intake seem to be able to adapt to the luteal phase increase of basal body temperature through reduced urinary volume and increased sweating rate.

  5. Maintenance of sweat glands by stem cells located in the acral epithelium

    Energy Technology Data Exchange (ETDEWEB)

    Ohe, Shuichi [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Dermatology, Kansai Medical University, Osaka 573-1010 (Japan); Tanaka, Toshihiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Third Department of Internal Medicine, Kansai Medical University, Osaka 573-1010 (Japan); Yanai, Hirotsugu [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Surgery, Kansai Medical University, Osaka 573-1010 (Japan); Komai, Yoshihiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Urology and Andrology, Kansai Medical University, Osaka 573-1010 (Japan); Omachi, Taichi [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Pediatrics, Kansai Medical University, Osaka 573-1010 (Japan); Kanno, Shohei; Tanaka, Kiyomichi; Ishigaki, Kazuhiko; Saiga, Kazuho [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Nakamura, Naohiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Third Department of Internal Medicine, Kansai Medical University, Osaka 573-1010 (Japan); Ohsugi, Haruyuki [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Urology and Andrology, Kansai Medical University, Osaka 573-1010 (Japan); Tokuyama, Yoko; Atsumi, Naho; Hisha, Hiroko; Yoshida, Naoko; Kumano, Keiki [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Yamazaki, Fumikazu; Okamoto, Hiroyuki [Department of Dermatology, Kansai Medical University, Osaka 573-1010 (Japan); Ueno, Hiroo, E-mail: hueno@hirakata.kmu.ac.jp [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan)

    2015-10-23

    The skin is responsible for a variety of physiological functions and is critical for wound healing and repair. Therefore, the regenerative capacity of the skin is important. However, stem cells responsible for maintaining the acral epithelium had not previously been identified. In this study, we identified the specific stem cells in the acral epithelium that participate in the long-term maintenance of sweat glands, ducts, and interadnexal epidermis and that facilitate the regeneration of these structures following injury. Lgr6-positive cells and Bmi1-positive cells were found to function as long-term multipotent stem cells that maintained the entire eccrine unit and the interadnexal epidermis. However, while Lgr6-positive cells were rapidly cycled and constantly supplied differentiated cells, Bmi1-positive cells were slow to cycle and occasionally entered the cell cycle under physiological conditions. Upon irradiation-induced injury, Bmi1-positive cells rapidly proliferated and regenerated injured epithelial tissue. Therefore, Bmi1-positive stem cells served as reservoir stem cells. Lgr5-positive cells were rapidly cycled and maintained only sweat glands; therefore, we concluded that these cells functioned as lineage-restricted progenitors. Taken together, our data demonstrated the identification of stem cells that maintained the entire acral epithelium and supported the different roles of three cellular classes. - Highlights: • The acral epithelium have two types of stem cells. • Lgr6-positive cells are rapid-cycling, short-term stem cells. • Bmi1-positive cells are slow-cycling stem cells that act as reserver stem cells. • Lgr5 may be a useful sweat gland marker in mice.

  6. Evaluation of fluid intake, weight loss and sweat rate in young triathletes

    Directory of Open Access Journals (Sweden)

    María Cristina Sellés López de Castro

    2015-10-01

    Full Text Available Introduction: Triathlon is an endurance sport comprising three disciplines: swimming, cycling and running. It is necessary to purpose guidelines in order to avoid dehydration during training or competition and keep good hydration before, during and after physical activity. The aim of this study is to evaluation of fluid intake, weight loss and sweat rate in young triathletes, during different trainings.Material and Methods: A descriptive-observational study in 14 triathletes (7 boys and 7 girls during a session of swimming, other session of cycling, another session of running. Fluid intake, weight loss, % of total body water, % dehydration and sweat rate, were assessed. Triathletes drank water in their drums of 750 ml and urine measurement was performed in containers.Results: The results of our study following the next order: swimming, cycling and running. Water intake 2.66±1.94ml/min, 7.91±7.69ml/min y 7.08±4.13ml/min in boys and 3.43±1.53ml/min, 6.39±5.36ml/min y 8.33±2.74ml/min in girls; weight loss 0.83±0.5kg, 0.47±0.3kg y 0.98±0.4kg in boys and 0.79±0.3kg, 0.47±0.58kg y 0.28±0.21kg in girls; and sweating rate 4.44±4.9ml/ min, 11.81±6.46ml/min y 5.29±3.13ml/min in boys and 3.89±2.4ml/min, 4.69±4.20ml/min and 7.96±5.06ml/min in girls.Conclusions: The percentage of body water and dehydration, loss of weight and sweat rate were compared with other studies and it´s shown that our results are lower than others studies, being below the recommendations of liquid intake in athletes.

  7. Estimating the chloride transport in cement paste

    Directory of Open Access Journals (Sweden)

    Princigallo, A.

    2012-06-01

    Full Text Available A method was developed to measure the diffusion coefficient of chloride ions in cement paste based on an analytical solution to Fick’s 2nd law in a cylindrical coordinate system. This natural method yielded diffusivity results within as little as a month. Testing time was reduced by exploiting the three-dimensional inward flux in the specimen. In an attempt to determine the saturation concentration, dense portland cement pastes were exposed to a concentrated chloride solution. The method proved to be useful for exploring cement hydration-induced changes in the diffusion coefficient of cement paste.

    Se ha desarrollado un método para medir el coeficiente de difusión de los iones cloruro en la pasta de cemento, partiendo de una aplicación analítica de la segunda ley de Fick en un sistema de coordinadas cilíndrico. Este método, que es natural, demostró ser capaz de producir resultados de difusividad en tan solo un mes. Se consiguió reducir el tiempo de ensayo mediante el aprovechamiento de la tridimensionalidad del flujo desde el exterior al interior de la probeta. A fin de determinar la concentración de saturación, se sometieron las pastas de cemento Portland a una disolución de cloruros concentrada. Este método resultó ser útil en el estudio de los cambios del coeficiente de difusión de la pasta de cemento provocados por las reacciones de hidratación que tienen lugar en esta.

  8. Sodium-metal chloride batteries

    Science.gov (United States)

    Ratnakumar, B. V.; Attia, A. I.; Halpert, G.

    1992-02-01

    It was concluded that rapid development in the technology of sodium metal chloride batteries has been achieved in the last decade mainly due to the: expertise available with sodium sulfur system; safety; and flexibility in design and fabrication. Long cycle lives of over 1000 and high energy densities of approx. 100 Wh/kg have been demonstrated in both Na/FeCl2 and Na/NiCl2 cells. Optimization of porous cathode and solid electrolyte geometries are essential for further enhancing the battery performance. Fundamental studies confirm the capabilities of these systems. Nickel dichloride emerges as the candidate cathode material for high power density applications such as electric vehicle and space.

  9. Chloride binding site of neurotransmitter sodium symporters

    DEFF Research Database (Denmark)

    Kantcheva, Adriana Krassimirova; Quick, Matthias; Shi, Lei

    2013-01-01

    Neurotransmitter:sodium symporters (NSSs) play a critical role in signaling by reuptake of neurotransmitters. Eukaryotic NSSs are chloride-dependent, whereas prokaryotic NSS homologs like LeuT are chloride-independent but contain an acidic residue (Glu290 in LeuT) at a site where eukaryotic NSSs ...

  10. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.

    1999-01-01

    In this paper chloride ingress in cement paste and mortar is followed by electron probe microanalysis. The influence of several paste and exposure parameters on chloride ingress are examined (e.g., water-cement ratio, silica fume addition, exposure time, and temperature), The measurements...

  11. 21 CFR 182.8985 - Zinc chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Zinc chloride. 182.8985 Section 182.8985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a...

  12. Electrochemical Chloride extraction using external electrodes?

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Pedersen, Anne Juul

    2006-01-01

    Electrochemical methods for the removal of chloride from concrete have been developed and the methods are primarily designed for situations where corrosion has started due to an increased chloride concentration in the vicinity of the reinforcement. In these methods the reinforcement is used as th...

  13. Chronopotentiometric chloride sensing using transition time measurement

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, D.B.; Olthuis, Wouter; van den Berg, Albert

    2013-01-01

    Detection of chloride ions is crucial to accurately access the concrete structure durability[1]. The existing electrochemical method of chloride ions detection in concrete, potentiometry[1], is not suitable for in-situ measurement due to the long term stability issue of conventional reference

  14. Uptake of tridodecylmethylammonium chloride by PVC

    NARCIS (Netherlands)

    Froehling, P.E.; Koenhen, D.M.; Smolders, C.A.; Bantjes, A.

    1977-01-01

    The uptake of tridodecylmethylammonium chloride (TDMAC) by poly(vinyl chloride) has been investigated to provide a more quantitative basis for the preparation of blood-compatible surfaces based on TDMAC-heparin coatings. Sorption isotherms of TDMAC from toluene-cyclohexane and toluene-methanol

  15. Nitrate removal from water using alum and ferric chloride: A comparative study of alum and ferric chloride efficiency

    Directory of Open Access Journals (Sweden)

    Ali Ahmad Aghapour

    2016-03-01

    Full Text Available Background: Nitrate is an acute and well-known hazardous contaminant, and its contamination of water sources has been a growing concern worldwide in recent years. This study evaluated the feasibility of nitrate removal from water using the traditional coagulants alum and ferric chloride with lower concentrations than those used in the conventional coagulation process. Methods: In this research, two coagulants, alum and ferric chloride, were compared for their efficiency in removing nitrate in a conventional water treatment system. The removal process was done in a batch system (jar test to examine the effects of coagulant dosages and determine the conditions required to achieve optimum results. Results: The results revealed that ferric chloride at an initial dose rate of 4 mg/L reduced nitrate concentration from 70 mg/L to less than the World Health Organization (WHO guideline value (50 mg/L N-NO 3. However, the removal efficiency of alum was not salient to significant nitrate reduction. Conclusion: In conclusion, ferric chloride was more effective than alumin removing NO-3, even in common dosage range, and can be considered a cost-effective and worthy treatment option to remediate nitratepolluted water. Furthermore, the removal of nitrate by coagulation can be simple and more economical than other treatment alternatives.

  16. Voluntary drinking versus imposed drinking in the methodology of investigations about the drinking-induced thermoregulatory sweating.

    Science.gov (United States)

    Hosseinlou, Abdollah; Khamnei, Saeed; Zamanlu, Masumeh

    2014-01-01

    Studies have shown that dehydrated humans or animals in a warm environment begin to sweat within seconds to minutes after drinking. This phenomenon is one of the drinking-induced thermoregulatory responses; being investigated from different aspects. Our objective is to show the difference of voluntary drinking and imposed drinking in the methodology of these experiments. Six healthy subjects 23.7 ± 0.6 yr old and 80.7 ± 5.7 kg wt were dehydrated by performing mild exercise (ergometer cycling) in a hot and humid chamber (38-40°C, 20-28% relative humidity). We incorporated two protocols: after dehydration, subjects were allowed to drink water with 1) imposed volumes of 1, 3, 5 ml/kg and 2) voluntary volumes; on four separate days. The sweating rate was measured on the forehead area before and after drinking. Sweating increased markedly just a few minutes after the onset of drinking. The mean sweat rates of the imposed volumes of 1, 3, 5 ml/Kg were 0.33 ± 0.15, 0.31 ± 0.17, 0.47 ± 0.21 respectively and for the voluntary volume it was 0.54 ± 0.19. The mean intake in the voluntary trial was 6.58 ± 1.14 ml/Kg, more than the imposed volume of 5 ml/Kg. The trend of the rate of the sweating response in the imposed trials was distinct from the response in the voluntary trial. There exists a difference between voluntary drinking and imposed drinking in the sweating response that follows rehydration. So it is suggested to use the methods of voluntary drinking in the investigations of this phenomenon, to reveal the natural events that happen in the actual circumstances.

  17. Dissolution of the metal sensitizers Ni, Be, Cr in artificial sweat to improve estimates of dermal bioaccessibility.

    Science.gov (United States)

    Stefaniak, Aleksandr B; Duling, Mathew G; Geer, Laura; Virji, M Abbas

    2014-02-01

    Dermal exposure to sensitizing metals is a serious occupational and public health problem. The usual approach to dermal exposure assessment is to process samples by chemical methods that use reactants to digest the metal particles and quantify the mass. In the case of dermal exposure assessment, these reactants are not representative of the skin surface film liquids and hence, may overestimate bioaccessibility. We hypothesize that the amount and form of sensitizer on a sample that leaches in a biological fluid, as can be estimated using artificial sweat, may be a more relevant metric for assessing health risks. Beryllium metal (Be), nickel metal (Ni), and chromium carbide (Cr3C2) particles were characterized and masses of sensitizing ions were measured using established reactant-assisted digestion procedures and extraction in artificial sweat under physiologically relevant conditions. Chromium ions released into artificial sweat were speciated to understand valence states. The ratios of the fraction of metal dissolved in artificial sweat relative to that dissolved by chemical-specific reactants were 1/2 (Be), 1/108 (Ni), and 1/2500 (Cr). The divalent Be and Ni cations were stable in artificial sweat over time (did not precipitate) whereas hexavalent chromium [Cr(VI)] ions decayed over time. Further analysis using speciated isotope dilution mass spectrometry revealed that the decay of Cr(VI) was accompanied by the formation of Cr(III) in the sweat model. Use of reactant-assisted analytical chemistry to quantify amounts of metal sensitizers on samples could overestimate biologically relevant exposure. In addition to mass, the valence state also influences penetration through the outer stratum corneum of the skin and is an important consideration when assessing exposure to complex sensitizers such as Cr which have multiple valence states with differing penetration efficiencies.

  18. Simple chloride sensors for continuous groundwater monitoring

    DEFF Research Database (Denmark)

    Thorn, Paul; Mortensen, John

    2012-01-01

    The development of chloride sensors which can be used for continuous, on-line monitoring of groundwater could be very valuable in the management of our coastal water resources. However, sensor stability, drift, and durability all need to be addressed in order for the sensors to be used in continu......The development of chloride sensors which can be used for continuous, on-line monitoring of groundwater could be very valuable in the management of our coastal water resources. However, sensor stability, drift, and durability all need to be addressed in order for the sensors to be used...... sensor remained responsive even at low chloride concentrations, where the conductivity electrode was no longer responding to changing chloride levels. With the results, it is believed that the simple chloride sensor could be used for continuous monitoring of groundwater quality....

  19. Salt equivalence and temporal dominance of sensations of different sodium chloride substitutes in butter.

    Science.gov (United States)

    de Souza, Vanessa Rios; Freire, Tassyana Vieira Marques; Saraiva, Carla Gonçalves; de Deus Souza Carneiro, João; Pinheiro, Ana Carla Marques; Nunes, Cleiton Antônio

    2013-08-01

    Studies indicate a positive association between dietary salt intake and some diseases, which has promoted the tendency to reduce the sodium in foods. The objective of this study was to determine the equivalent amount of different sodium chloride replacements required to promote the same degree of ideal saltiness in butter and to study the sensory profile of sodium chloride and the substitutes using the analysis of Temporal Dominance of Sensations (TDS). Using the magnitude estimation method, it was determined that the potencies of potassium chloride, monosodium glutamate and potassium phosphate relative to the 1% sodium chloride in butter are 83·33, 31·59 and 33·32, respectively. Regarding the sensory profile of the tested salt substitutes, a bitter taste was perceived in the butter with potassium chloride, a sour taste was perceived in the butter with potassium phosphate and sweet and umami tastes were dominant in the butter with monosodium glutamate. Of all the salt substitutes tested calcium lactate, potassium lactate, calcium chloride and magnesium chloride were impractical to use in butter.

  20. Highly abundant defense proteins in human sweat as revealed by targeted proteomics and label-free quantification mass spectrometry.

    Science.gov (United States)

    Csősz, É; Emri, G; Kalló, G; Tsaprailis, G; Tőzsér, J

    2015-10-01

    The healthy human skin with its effective antimicrobial defense system forms an efficient barrier against invading pathogens. There is evidence suggesting that the composition of this chemical barrier varies between diseases, making the easily collected sweat an ideal candidate for biomarker discoveries. Our aim was to provide information about the normal composition of the sweat, and to study the chemical barrier found at the surface of skin. Sweat samples from healthy individuals were collected during sauna bathing, and the global protein panel was analysed by label-free mass spectrometry. SRM-based targeted proteomic methods were designed and stable isotope labelled reference peptides were used for method validation. Ninety-five sweat proteins were identified, 20 of them were novel proteins. It was shown that dermcidin is the most abundant sweat protein, and along with apolipoprotein D, clusterin, prolactin-inducible protein and serum albumin, they make up 91% of secreted sweat proteins. The roles of these highly abundant proteins were reviewed; all of which have protective functions, highlighting the importance of sweat glands in composing the first line of innate immune defense system, and maintaining the epidermal barrier integrity. Our findings with regard to the proteins forming the chemical barrier of the skin as determined by label-free quantification and targeted proteomics methods are in accordance with previous studies, and can be further used as a starting point for non-invasive sweat biomarker research. © 2015 European Academy of Dermatology and Venereology.