WorldWideScience

Sample records for swab samples food

  1. Comparison of air samples, nasal swabs, ear-skin swabs and environmental dust samples for detection of Methicillin Resistant Staphylococcus aureus (MRSA) in pig herds

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Vigre, Håkan; Cavaco, Lina

    2014-01-01

    To identify a cost-effective and practical method for detection of methicillin-resistant Staphylococcus aureus (MRSA) in pig herds, the relative sensitivity of four sample types: nasal swabs, ear-skin (skin behind the ears) swabs, environmental dust swabs and air was compared. Moreover, dependency......-herd prevalence ⩾25%]. The results indicate that taking swabs of skin behind the ears (ten pools of five) was even more sensitive than taking nasal swabs (ten pools of five) at the herd level and detected significantly more positive samples. spa types t011, t034 and t4208 were observed. In conclusion, MRSA...... detection by air sampling is easy to perform, reduces costs and analytical time compared to existing methods, and is recommended for initial testing of herds. Ear-skin swab sampling may be more sensitive for MRSA detection than air sampling or nasal swab sampling....

  2. A simplified field protocol for genetic sampling of birds using buccal swabs

    Science.gov (United States)

    Vilstrup, Julia T.; Mullins, Thomas D.; Miller, Mark P.; McDearman, Will; Walters, Jeffrey R.; Haig, Susan M.

    2018-01-01

    DNA sampling is an essential prerequisite for conducting population genetic studies. For many years, blood sampling has been the preferred method for obtaining DNA in birds because of their nucleated red blood cells. Nonetheless, use of buccal swabs has been gaining favor because they are less invasive yet still yield adequate amounts of DNA for amplifying mitochondrial and nuclear markers; however, buccal swab protocols often include steps (e.g., extended air-drying and storage under frozen conditions) not easily adapted to field settings. Furthermore, commercial extraction kits and swabs for buccal sampling can be expensive for large population studies. We therefore developed an efficient, cost-effective, and field-friendly protocol for sampling wild birds after comparing DNA yield among 3 inexpensive buccal swab types (2 with foam tips and 1 with a cotton tip). Extraction and amplification success was high (100% and 97.2% respectively) using inexpensive generic swabs. We found foam-tipped swabs provided higher DNA yields than cotton-tipped swabs. We further determined that omitting a drying step and storing swabs in Longmire buffer increased efficiency in the field while still yielding sufficient amounts of DNA for detailed population genetic studies using mitochondrial and nuclear markers. This new field protocol allows time- and cost-effective DNA sampling of juveniles or small-bodied birds for which drawing blood may cause excessive stress to birds and technicians alike.

  3. Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident

    International Nuclear Information System (INIS)

    Fukutsu, Kumiko; Yamada, Yuji; Kurihara, Osamu; Akashi, Makoto; Momose, Takumaro; Miyabe, Kenjiro

    2008-01-01

    At nuclear emergency accident such as inhalation intake of alpha nuclide, an indispensable nasal swab method has not been used for the precise internal dose estimation. One of the reasons is uncertainty in its radiation measurement, so that precise measurement with alpha spectrometry was examined for filter samples simulating nasal swab. It was confirmed that the alpha spectrometry made possible the distinction between solution and particulate in addition to the nuclide identification. The alpha activity in swab sample was precisely evaluated only when the detection efficiency was determined considering the self-absorption with filter fibers. Another big problem of wiping efficiency in nasal swabbing is still remain, but this study certainly raised the usefulness of the nasal swab method for rapid response in emergency. (author)

  4. Rectal swab screening assays of public health importance in molecular diagnostics: Sample adequacy control.

    Science.gov (United States)

    Glisovic, Sanja; Eintracht, Shaun; Longtin, Yves; Oughton, Matthew; Brukner, Ivan

    Rectal swabs are routinely used by public health authorities to screen for multi-drug resistant enteric bacteria including vancomycin-resistant enterococci (VRE) and carbapenem-resistant enterobacteriaceae (CRE). Screening sensitivity can be influenced by the quality of the swabbing, whether performed by the patient (self-swabbing) or a healthcare practitioner. One common exclusion criterion for rectal swabs is absence of "visible soiling" from fecal matter. In our institution, this criterion excludes almost 10% of rectal swabs received in the microbiology laboratory. Furthermore, over 30% of patients in whom rectal swabs are cancelled will not be re-screened within the next 48h, resulting in delays in removing infection prevention measures. We describe two quantitative polymerase chain reaction (qPCR)-based assays, human RNAse P and eubacterial 16S rDNA, which might serve as suitable controls for sampling adequacy. However, lower amounts of amplifiable human DNA make the 16s rDNA assay a better candidate for sample adequacy control. Copyright © 2017. Published by Elsevier Ltd.

  5. APTIMA assay on SurePath liquid-based cervical samples compared to endocervical swab samples facilitated by a real time database

    Directory of Open Access Journals (Sweden)

    Khader Samer

    2010-01-01

    Full Text Available Background: Liquid-based cytology (LBC cervical samples are increasingly being used to test for pathogens, including: HPV, Chlamydia trachomatis (CT and Neisseria gonorrhoeae (GC using nucleic acid amplification tests. Several reports have shown the accuracy of such testing on ThinPrep (TP LBC samples. Fewer studies have evaluated SurePath (SP LBC samples, which utilize a different specimen preservative. This study was undertaken to assess the performance of the Aptima Combo 2 Assay (AC2 for CT and GC on SP versus endocervical swab samples in our laboratory. Materials and Methods: The live pathology database of Montefiore Medical Center was searched for patients with AC2 endocervical swab specimens and SP Paps taken the same day. SP samples from CT- and/or GC-positive endocervical swab patients and randomly selected negative patients were studied. In each case, 1.5 ml of the residual SP vial sample, which was in SP preservative and stored at room temperature, was transferred within seven days of collection to APTIMA specimen transfer tubes without any sample or patient identifiers. Blind testing with the AC2 assay was performed on the Tigris DTS System (Gen-probe, San Diego, CA. Finalized SP results were compared with the previously reported endocervical swab results for the entire group and separately for patients 25 years and younger and patients over 25 years. Results: SP specimens from 300 patients were tested. This included 181 swab CT-positive, 12 swab GC-positive, 7 CT and GC positive and 100 randomly selected swab CT and GC negative patients. Using the endocervical swab results as the patient′s infection status, AC2 assay of the SP samples showed: CT sensitivity 89.3%, CT specificity 100.0%; GC sensitivity and specificity 100.0%. CT sensitivity for patients 25 years or younger was 93.1%, versus 80.7% for patients over 25 years, a statistically significant difference (P = 0.02. Conclusions: Our results show that AC2 assay of 1.5 ml SP

  6. Simplifying sampling for African swine fever surveillance: Assessment of antibody and pathogen detection from blood swabs.

    Science.gov (United States)

    Carlson, J; Zani, L; Schwaiger, T; Nurmoja, I; Viltrop, A; Vilem, A; Beer, M; Blome, S

    2018-02-01

    African swine fever (ASF) is a notifiable disease with serious socio-economic consequences that has been present in wild boar in the Baltic States and Poland since 2014. An introduction of ASF is usually accompanied by increased mortality, making fallen wild boar and hunted animals with signs of disease the main target for early warning and passive surveillance. It is difficult, however, to encourage hunters and foresters to report and take samples from these cases. A pragmatic and easy sampling approach with quick-drying swabs could facilitate this. In this study, we further evaluated the use of dry blood swabs for the detection of ASFV antibody and genome with samples from animal trials and diagnostic submissions (blood, bone and organs) from Estonia. Compared to serum samples, dried blood swabs yielded 93.1% (95% confidence interval: [83.3, 98.1]) sensitivity and 100% [95.9, 100.0] specificity in a commercial ASFV antibody ELISA. Similarly, the swabs gave a sensitivity of 98.9% [93.4, 100.0] and a specificity of 98.1% [90.1, 100.0] for genome detection by a standard ASFV p72 qPCR when compared to EDTA blood. The same swabs were tested in a VP72-antibody lateral flow device, with a sensitivity of 94.7% [85.4, 98.9] and specificity of 96.1% [89.0, 99.2] compared to the serum ELISA. When GenoTube samples tested in ELISA and LFD were compared, the sensitivity was 96.3% [87.3, 99.5] and the specificity was 93.8% [86.0, 97.9]. This study demonstrates reliable detection of ASFV antibody and genome from swabs. A field test of the swabs with decomposed wild boar carcasses in an endemic area in Estonia also gave promising results. Thus, this technique is a practical approach for surveillance of ASF in both free and endemic areas. © 2017 Blackwell Verlag GmbH.

  7. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  8. Direct PCR amplification of DNA from human bloodstains, saliva, and touch samples collected with microFLOQ® swabs.

    Science.gov (United States)

    Ambers, Angie; Wiley, Rachel; Novroski, Nicole; Budowle, Bruce

    2018-01-01

    Previous studies have shown that nylon flocked swabs outperform traditional fiber swabs in DNA recovery due to their innovative design and lack of internal absorbent core to entrap cellular materials. The microFLOQ ® Direct swab, a miniaturized version of the 4N6 FLOQSwab ® , has a small swab head that is treated with a lysing agent which allows for direct amplification and DNA profiling from sample collection to final result in less than two hours. Additionally, the microFLOQ ® system subsamples only a minute portion of a stain and preserves the vast majority of the sample for subsequent testing or re-analysis, if desired. The efficacy of direct amplification of DNA from dilute bloodstains, saliva stains, and touch samples was evaluated using microFLOQ ® Direct swabs and the GlobalFiler™ Express system. Comparisons were made to traditional methods to assess the robustness of this alternate workflow. Controlled studies with 1:19 and 1:99 dilutions of bloodstains and saliva stains consistently yielded higher STR peak heights than standard methods with 1ng input DNA from the same samples. Touch samples from common items yielded single source and mixed profiles that were consistent with primary users of the objects. With this novel methodology/workflow, no sample loss occurs and therefore more template DNA is available during amplification. This approach may have important implications for analysis of low quantity and/or degraded samples that plague forensic casework. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs.

    Science.gov (United States)

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus; Morling, Niels

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing.

  10. Evaluation of Two Surface Sampling Methods for Microbiological and Chemical Analyses To Assess the Presence of Biofilms in Food Companies.

    Science.gov (United States)

    Maes, Sharon; Huu, Son Nguyen; Heyndrickx, Marc; Weyenberg, Stephanie van; Steenackers, Hans; Verplaetse, Alex; Vackier, Thijs; Sampers, Imca; Raes, Katleen; Reu, Koen De

    2017-12-01

    Biofilms are an important source of contamination in food companies, yet the composition of biofilms in practice is still mostly unknown. The chemical and microbiological characterization of surface samples taken after cleaning and disinfection is very important to distinguish free-living bacteria from the attached bacteria in biofilms. In this study, sampling methods that are potentially useful for both chemical and microbiological analyses of surface samples were evaluated. In the manufacturing facilities of eight Belgian food companies, surfaces were sampled after cleaning and disinfection using two sampling methods: the scraper-flocked swab method and the sponge stick method. Microbiological and chemical analyses were performed on these samples to evaluate the suitability of the sampling methods for the quantification of extracellular polymeric substance components and microorganisms originating from biofilms in these facilities. The scraper-flocked swab method was most suitable for chemical analyses of the samples because the material in these swabs did not interfere with determination of the chemical components. For microbiological enumerations, the sponge stick method was slightly but not significantly more effective than the scraper-flocked swab method. In all but one of the facilities, at least 20% of the sampled surfaces had more than 10 2 CFU/100 cm 2 . Proteins were found in 20% of the chemically analyzed surface samples, and carbohydrates and uronic acids were found in 15 and 8% of the samples, respectively. When chemical and microbiological results were combined, 17% of the sampled surfaces were contaminated with both microorganisms and at least one of the analyzed chemical components; thus, these surfaces were characterized as carrying biofilm. Overall, microbiological contamination in the food industry is highly variable by food sector and even within a facility at various sampling points and sampling times.

  11. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Science.gov (United States)

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Frédéric; Petignat, Patrick

    2015-01-01

    Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY) or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA). After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET). HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic. HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2) detected by s-DRY, 56.2% (95%CI: 47.6-64.4) by Dr-WET, and 54.6% (95%CI: 46.1-62.9) by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34), and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56). Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+) were: 64.0% (95%CI: 44.5-79.8) for s-FTA, 84.6% (95%CI: 66.5-93.9) for s-DRY, and 76.9% (95%CI: 58.0-89.0) for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%). Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD)/per card vs. ~1 USD/per swab). Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA. International Standard Randomized Controlled Trial Number (ISRCTN): 43310942.

  12. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Directory of Open Access Journals (Sweden)

    Rosa Catarino

    Full Text Available Human papillomavirus (HPV self-sampling (self-HPV is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab.A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA. After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET. HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic.HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2 detected by s-DRY, 56.2% (95%CI: 47.6-64.4 by Dr-WET, and 54.6% (95%CI: 46.1-62.9 by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34, and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56. Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+ were: 64.0% (95%CI: 44.5-79.8 for s-FTA, 84.6% (95%CI: 66.5-93.9 for s-DRY, and 76.9% (95%CI: 58.0-89.0 for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%. Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD/per card vs. ~1 USD/per swab.Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA.International Standard Randomized Controlled Trial Number (ISRCTN: 43310942.

  13. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge

    OpenAIRE

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Fr?d?ric; Petignat, Patrick

    2015-01-01

    Background Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. Methods A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed f...

  14. The detection and antimicrobial susceptibility profile of Shigella isolates from meat and swab samples at butchers' shops in Gondar town, Northwest Ethiopia.

    Science.gov (United States)

    Garedew, Legesse; Hagos, Zenabu; Zegeye, Bidir; Addis, Zelalem

    2016-01-01

    Food borne pathogens are major causes of deaths, illnesses and billions of dollars of expenses. The burden of food borne illness is worsened by the ever increasing rate of antimicrobial resistance microbes. Shigella, a bacterial pathogen associated with food, is reported to account for higher prevalence rates of food borne illness in different settings. A cross-sectional study was conducted from February 10 to June 30, 2013, at the butcher houses of Gondar town in the Northwest of Ethiopia to assess the prevalence and antimicrobial susceptibility pattern of Shigella. Cattle raw meat and swab samples from selected critical control points, including knives, chopping boards, and the hands and noses of butchers, were collected and analyzed. The identification of Shigella was carried out using colony characteristics, the Gram reaction, and biochemical tests. Antimicrobial susceptibility testing was performed using the Kirby-Bauer disc diffusion method. The overall hygienic status of the butcher shops was also assessed using a checklist. An observational analysis revealed that the sanitary condition of the butcher shops and their premises was poor. Of 306 samples screened, 10.5% were positive for Shigella. Approximately 7.4% of meat samples and 10.2% of swab samples were contaminated with Shigella. Out of the total Shigella isolates, 90.6%, 46.9%, 18.8% and 9.4% were resistant to ampicillin, amoxicillin, ceftriaxone and tetracycline, respectively. A multidrug resistance pattern was recorded in 27.8% of the isolates. In conclusion, the safety of meat sold at Gondar butchers houses was poor. The identified Shigella isolates showed high levels of drug resistance and multidrug resistance patterns for commonly used antimicrobials in veterinary and human medicine. Practicing wise use of antimicrobials and strict sanitary interventions at different critical control points is strongly recommended, in addition to further in-depth studies to prevent unprecedented consequences from

  15. Rectal swabs for analysis of the intestinal microbiota.

    Directory of Open Access Journals (Sweden)

    Andries E Budding

    Full Text Available The composition of the gut microbiota is associated with various disease states, most notably inflammatory bowel disease, obesity and malnutrition. This underlines that analysis of intestinal microbiota is potentially an interesting target for clinical diagnostics. Currently, the most commonly used sample types are feces and mucosal biopsy specimens. Because sampling method, storage and processing of samples impact microbiota analysis, each sample type has its own limitations. An ideal sample type for use in routine diagnostics should be easy to obtain in a standardized fashion without perturbation of the microbiota. Rectal swabs may satisfy these criteria, but little is known about microbiota analysis on these sample types. In this study we investigated the characteristics and applicability of rectal swabs for gut microbiota profiling in a clinical routine setting in patients presenting with various gastro-intestinal disorders. We found that rectal swabs appeared to be a convenient means of sampling the human gut microbiota. Swabs can be performed on demand, whenever a patient presents; swab-derived microbiota profiles are reproducible, whether they are gathered at home by patients or by medical professionals in an outpatient setting and may be ideally suited for clinical diagnostics and large-scale studies.

  16. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs

    DEFF Research Database (Denmark)

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards...

  17. Validation of Performance of the Gen-Probe Human Immunodeficiency Virus Type 1 Viral Load Assay with Genital Swabs and Breast Milk Samples

    Science.gov (United States)

    DeVange Panteleeff, Dana; Emery, Sandra; Richardson, Barbra A.; Rousseau, Christine; Benki, Sarah; Bodrug, Sharon; Kreiss, Joan K.; Overbaugh, Julie

    2002-01-01

    Human immunodeficiency type 1 (HIV-1) continues to spread at an alarming rate. The virus may be transmitted through blood, genital secretions, and breast milk, and higher levels of systemic virus in the index case, as measured by plasma RNA viral load, have been shown to correlate with increased risk of transmitting HIV-1 both vertically and sexually. Less is known about the correlation between transmission and HIV-1 levels in breast milk or genital secretions, in part because reliable quantitative assays to detect HIV-1 in these fluids are not available. Here we show that the Gen-Probe HIV-1 viral load assay can be used to accurately quantify viral load in expressed breast milk and in cervical and vaginal samples collected on swabs. Virus could be quantified from breast milk and swab samples spiked with known amounts of virus, including HIV-1 subtypes A, C, and D. As few as 10 copies of HIV-1 RNA could be detected above background threshold levels in ≥77% of assays performed with spiked breast milk supernatants and mock swabs. In genital swab samples from HIV-1-infected women, similar levels of HIV-1 RNA were consistently detected in duplicate swabs taken from the same woman on the same clinic visit, suggesting that the RNA values from a single swab sample can be used to measure genital viral load. PMID:12409354

  18. Meatal Swabs Contain Less Cellular Material and Are Associated with a Decrease in Gram Stain Smear Quality Compared to Urethral Swabs in Men.

    Science.gov (United States)

    Jordan, Stephen J; Schwebke, Jane R; Aaron, Kristal J; Van Der Pol, Barbara; Hook, Edward W

    2017-07-01

    Urethral swabs are the samples of choice for point-of-care Gram stain testing to diagnose Neisseria gonorrhoeae infection and nongonococcal urethritis (NGU) in men. As an alternative to urethral swabs, meatal swabs have been recommended for the collection of urethral discharge to diagnose N. gonorrhoeae and Chlamydia trachomatis infection in certain populations by nucleic acid amplification testing (NAAT), as they involve a less invasive collection method. However, as meatal swabs could be sampling a reduced surface area and result in fewer collected epithelial cells compared to urethral swabs, the adequacy of meatal swab specimens to collect sufficient cellular material for Gram stain testing remains unknown. We enrolled 66 men who underwent either urethral or meatal swabbing and compared the cellular content and Gram stain failure rate. We measured the difference in swab cellular content using the Cepheid Xpert CT/NG sample adequacy control crossing threshold (SAC CT ) and determined the failure rate of Gram stain smears (GSS) due to insufficient cellular material. In the absence of discharge, meatal smears were associated with a significant reduction in cellular content ( P = 0.0118), which corresponded with a GSS failure rate significantly higher than that for urethral swabs (45% versus 3%, respectively; P < 0.0001). When discharge was present, there was no difference among results from urethral and meatal swabs. Therefore, if GSS testing is being considered for point-of-care diagnosis of N. gonorrhoeae infection or NGU in men, meatal swabs should be avoided in the absence of a visible discharge. Copyright © 2017 American Society for Microbiology.

  19. Primary health clinic toilet/bathroom surface swab sampling can indicate community profile of sexually transmitted infections

    Directory of Open Access Journals (Sweden)

    Philip M. Giffard

    2017-06-01

    known higher relative prevalence of gonorrhoeae in central Australia than in northern Australia. Similarly, the regional clinics yielded p values from 0.0088–0.0022. In contrast, swab and notifications data from the sexual health clinic were not correlated. Discussion Strong correlations between swab and notifications were observed. However, there was evidence for limitations of this approach. Despite the correlation observed with the regional clinics data, one clinic yielded zero positive swabs for C. trachomatis, although this STI constituted 25.1% of the corresponding notifications. This could be ascribed to stochastic effects. The lack of correlation observed for sexual health clinic data was also likely due to stochastic effects. It was concluded that toilet/bathroom surface swab sampling has considerable potential for public health surveillance. The approach may be applicable in situations other than primary health clinics, and for targets other than STIs.

  20. REAL-TIME PCR DETECTION OF LISTERIA MONOCYTOGENES IN FOOD SAMPLES OF ANIMAL ORIGIN

    Directory of Open Access Journals (Sweden)

    Jaroslav Pochop

    2013-02-01

    Full Text Available The aim of this study was to follow the contamination of food with Listeria monocytogenes by using Step One real time polymerase chain reaction (PCR. We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and SensiFAST SYBR Hi-ROX Kit for the real-time PCR performance. In 24 samples of food of animal origin without incubation were detected strains of Listeria monocytogenes in 15 samples (swabs. Nine samples were negative. Our results indicated that the real-time PCR assay developed in this study could sensitively detect Listeria monocytogenes in food of animal origin without incubation. This could prevent infection caused by Listeria monocytogenes, and also could benefit food manufacturing companies by extending their product’s shelf-life as well as saving the cost of warehousing their food products while awaiting pathogen testing results. The rapid real-time PCR-based method performed very well compared to the conventional method. It is a fast, simple, specific and sensitive way to detect nucleic acids, which could be used in clinical diagnostic tests in the future.

  1. Randomized comparison of vaginal self-sampling by standard vs. dry swabs for Human papillomavirus testing

    International Nuclear Information System (INIS)

    Eperon, Isabelle; Vassilakos, Pierre; Navarria, Isabelle; Menoud, Pierre-Alain; Gauthier, Aude; Pache, Jean-Claude; Boulvain, Michel; Untiet, Sarah; Petignat, Patrick

    2013-01-01

    To evaluate if human papillomavirus (HPV) self-sampling (Self-HPV) using a dry vaginal swab is a valid alternative for HPV testing. Women attending colposcopy clinic were recruited to collect two consecutive Self-HPV samples: a Self-HPV using a dry swab (S-DRY) and a Self-HPV using a standard wet transport medium (S-WET). These samples were analyzed for HPV using real time PCR (Roche Cobas). Participants were randomized to determine the order of the tests. Questionnaires assessing preferences and acceptability for both tests were conducted. Subsequently, women were invited for colposcopic examination; a physician collected a cervical sample (physician-sampling) with a broom-type device and placed it into a liquid-based cytology medium. Specimens were then processed for the production of cytology slides and a Hybrid Capture HPV DNA test (Qiagen) was performed from the residual liquid. Biopsies were performed if indicated. Unweighted kappa statistics (κ) and McNemar tests were used to measure the agreement among the sampling methods. A total of 120 women were randomized. Overall HPV prevalence was 68.7% (95% Confidence Interval (CI) 59.3–77.2) by S-WET, 54.4% (95% CI 44.8–63.9) by S-DRY and 53.8% (95% CI 43.8–63.7) by HC. Among paired samples (S-WET and S-DRY), the overall agreement was good (85.7%; 95% CI 77.8–91.6) and the κ was substantial (0.70; 95% CI 0.57-0.70). The proportion of positive type-specific HPV agreement was also good (77.3%; 95% CI 68.2-84.9). No differences in sensitivity for cervical intraepithelial neoplasia grade one (CIN1) or worse between the two Self-HPV tests were observed. Women reported the two Self-HPV tests as highly acceptable. Self-HPV using dry swab transfer does not appear to compromise specimen integrity. Further study in a large screening population is needed. ClinicalTrials.gov: http://clinicaltrials.gov/show/NCT01316120

  2. Well swab collar

    Energy Technology Data Exchange (ETDEWEB)

    1969-04-09

    A well swab collar which can be hoisted to bring well fluids upward through a pipe string is described. An elastic swab is used to swab a pipe having a predetermined diameter. The swab consists of a circular shaped elastomer body having an outer diameter a little smaller than the inner diameter of the pipe. The body is divided into multiple swab elements by ring-shaped grooves in the body. The swab element has truncated conical surfaces directed radially at an outward angle, then downward and consequently at an angle inward and then downward. (19 claims)

  3. Evaluation of two methods for monitoring surface cleanliness-ATP bioluminescence and traditional hygiene swabbing.

    Science.gov (United States)

    Davidson, C A; Griffith, C J; Peters, A C; Fielding, L M

    1999-01-01

    The minimum bacterial detection limits and operator reproducibility of the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test and traditional hygiene swabbing were determined. Areas (100 cm2) of food grade stainless steel were separately inoculated with known levels of Staphylococcus aureus (NCTC 6571) and Escherichia coli (ATCC 25922). Surfaces were sampled either immediately after inoculation while still wet, or after 60 min when completely dry. For both organisms the minimum detection limit of the ATP Clean-Tracetrade mark Rapid Cleanliness Test was 10(4) cfu/100 cm2 (p 10(7) cfu/100 cm2. Hygiene swabbing percentage recovery rates for both organisms were less than 0.1% for dried surfaces but ranged from 0.33% to 8.8% for wet surfaces. When assessed by six technically qualified operators, the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test gave superior reproducibility for both clean and inoculated surfaces, giving mean coefficients of variation of 24% and 32%, respectively. Hygiene swabbing of inoculated surfaces gave a mean CV of 130%. The results are discussed in the context of hygiene monitoring within the food industry. Copyright 1999 John Wiley & Sons, Ltd.

  4. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    Science.gov (United States)

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  5. Detection of Mycoplasma hyopneumoniae by ELISA and nested PCR from blood samples and nasal swabs from pigs in Slovakia

    Directory of Open Access Journals (Sweden)

    Marián Prokeš

    2012-01-01

    Full Text Available The aim of our study was to map the situation of swine mycoplasmoses on four farms in the region of Eastern Slovakia. The primary agent of Enzootic pneumonia of swine is Mycoplasma hyopneumoniae. After reviewing the health status of conventional herds and evaluation of clinical symptoms, paired samples of nasal swabs and venous blood samples were collected from 38 pigs with clinical signs of respiratory disease. Nasal swab samples were tested by nested PCR, while blood samples were used to detect antibodies against M. hyopneumoniae by blocking ELISA. The presence of M. hyopneumoniae was confirmed by nested PCR in four pigs (10.5% and by blocking ELISA in 16 pigs (42.1% of all four farms. This work presents for the first time comparison of different methods to diagnose M. hyopneumoniae infection on pig farms in Eastern Slovakia.

  6. Forensic analysis of explosive residues from hand swabs

    International Nuclear Information System (INIS)

    Umi Khairul Ahmad; Sumathy Rajendran; Syahidah Abu Hassan

    2008-01-01

    In the forensic examination of physical evidence for organic explosives, cotton swabs are often used to collect residue from surfaces, such as skin and post-blast debris. A preliminary study has been conducted to develop extraction method of a common energetic compound, pentaerythritol tetranitrate (PETN) from hand swabs followed by direct analysis of the resulting extract solution using high-performance liquid chromatography (HPLC) with ultraviolet (UV) detector. Analysis was performed on an octadecylsilane-based (C 18 ) column using acetonitrile-water mixture (55:45) as mobile phase. The mobile phase was pumped at 1.0 mL/ min and separation affected using an isocratic mode with the detection wavelength of 230 nm. The explosive residue was extracted from cotton swabs using acetone in an ultrasonic cold bath. The developed method was later applied to the real hand swabs samples, which were taken from three army personnel who handled PETN during a munition disposal operation at Asahan Camp Military Firing range. The acetone extract obtained using sonication method was found to be effective in recovering PETN from cotton swabs with relatively high recovery (89.5 %) and good sensitivity with detection limit as low as 2 ng. The content of PETN in the real hand swab samples were found to be in the range of 4.7-130 mg. (author)

  7. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    Directory of Open Access Journals (Sweden)

    Nadja Sparding

    Full Text Available After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  8. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Lee, Soomin; Nishimura, Takayuki; Katsuura, Tetsuo; Yasukouchi, Akira

    2011-01-10

    Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO). In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). The melatonin levels were analyzed in duplicate using commercially available ELISA kits. The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL). The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level (<6 pg/mL), although the BA plots didn't show proportional and relative biases, there was no significant correlation between passive and cotton saliva collection samples. Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  9. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay

    Directory of Open Access Journals (Sweden)

    Katsuura Tetsuo

    2011-01-01

    Full Text Available Abstract Background Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO. In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Methods Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection and into clear sterile tubes (passive saliva collection. The melatonin levels were analyzed in duplicate using commercially available ELISA kits. Results The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL. The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level ( Conclusion Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  10. EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

    Science.gov (United States)

    Rucker, Michelle A.; Hood, Drew; Walker, Mary; Venkateswaran, Kasthuri J.; Schuerger, Andrew C.

    2018-01-01

    When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between

  11. Effects of saliva collection using cotton swab on cortisol enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Hashiguchi, Nobuko; Kaji, Yumi; Yasukouchi, Akira; Tochihara, Yutaka

    2009-12-01

    Cotton swabs are among the most commonly used devices for collecting saliva, but various studies have reported that their use impacts the results of salivary cortisol assays. These studies, however, estimated this impact by comparing the average of the concentration and/or scatter plots. In the present study, we estimated the impact of cotton swabs on the results of salivary cortisol enzyme immunoassay (EIA) by Bland-Altman plot. Eight healthy males (aged 20-23 years) provided four saliva samples on different days to yield a total of 32 samples. Saliva samples were collected directly in plastic tubes using plastic straws and then pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). There was a lower correlation between cotton and passive saliva collection. Individually, four subjects showed a negative correlation between passive and cotton saliva collection. A Bland-Altman plot indicated that cotton swabs causes a proportional bias on the EIA assay result. Our findings indicate a considerable effect of using cotton swabs for saliva collection, and subject-specific variability in the impact. A Bland-Altman plot further suggests possible reasons for this effect.

  12. Detection of Listeria spp. in food handling areas of retail food stores in the state of Pernambuco, Brazil

    Directory of Open Access Journals (Sweden)

    Mariana Gomes Ferreira Machado de Siqueira

    2017-07-01

    Full Text Available Abstract The identification of Listeria spp. in food handling areas is of great concern to health surveillance agencies, and their control is often hampered by the ability of the bacteria to grow and maintain themselves even under adverse conditions. The present study aimed to isolate and identify Listeria spp. in the food handling areas of 10 retail food stores in the state of Pernambuco, Brazil. Eighty-six swab samples were collected from equipment, utensils and surfaces used for processing ready-to-eat meat products. The Dry and Wet Swabbing Methods (3M™ Quick Swabs and 3M™ Petrifilm™ Plates were used to identify Listeria spp. Contamination by Listeria monocytogenes was confirmed by the Real-time Polymerase Chain Reaction (qPCR. The hygienic and sanitary conditions of the food handling areas of each store were also assessed. Listeria spp. was isolated in eight stores (80%. Of the 86 swab samples analyzed, 27 (31.2% [confidence interval 21.81% to 42.30%] were positive for Listeria spp. and only one (3.7% was confirmed as Listeria monocytogenes. The main contamination sites were the floor (50.0%, the plastic cutting board (42.9% and the knife (40.0%. None of the hygienic and sanitary conditions assessed in the present study were associated with contamination by Listeria spp. (p = 0.700. It was concluded that Listeria spp. was widely distributed in the retail food stores studied, being a possible risk factor for public health.

  13. Comparative study of the swabbing properties of seven commercially available swab materials for cleaning verification.

    Science.gov (United States)

    Corrigan, Damion K; Piletsky, Sergey; McCrossen, Sean

    2009-01-01

    This article compares the technical performances of several different commercially available swabbing materials for the purpose of cleaning verification. A steel surface was soiled with solutions of acetaminophen, nicotinic acid, diclofenac, and benzamidine and wiped with each swabbing material. The compounds were extracted with water or ethanol (depending on polarity of analyte) and their concentration in extract was quantified spectrophotometrically. The study also investigated swab debris on the wiped surface. The swab performances were compared and the best swab material was identified.

  14. A comparative evaluation of feathers, oropharyngeal swabs, and cloacal swabs for the detection of H5N1 highly pathogenic avian influenza virus infection in experimentally infected chickens and ducks.

    Science.gov (United States)

    Nuradji, Harimurti; Bingham, John; Lowther, Sue; Wibawa, Hendra; Colling, Axel; Long, Ngo Thanh; Meers, Joanne

    2015-11-01

    Oropharyngeal and cloacal swabs have been widely used for the detection of H5N1 highly pathogenic avian Influenza A virus (HPAI virus) in birds. Previous studies have shown that the feather calamus is a site of H5N1 virus replication and therefore has potential for diagnosis of avian influenza. However, studies characterizing the value of feathers for this purpose are not available, to our knowledge; herein we present a study investigating feathers for detection of H5N1 virus. Ducks and chickens were experimentally infected with H5N1 HPAI virus belonging to 1 of 3 clades (Indonesian clades 2.1.1 and 2.1.3, Vietnamese clade 1). Different types of feathers and oropharyngeal and cloacal swab samples were compared by virus isolation. In chickens, virus was detected from all sample types: oral and cloacal swabs, and immature pectorosternal, flight, and tail feathers. During clinical disease, the viral titers were higher in feathers than swabs. In ducks, the proportion of virus-positive samples was variable depending on viral strain and time from challenge; cloacal swabs and mature pectorosternal feathers were clearly inferior to oral swabs and immature pectorosternal, tail, and flight feathers. In ducks infected with Indonesian strains, in which most birds did not develop clinical signs, all sampling methods gave intermittent positive results; 3-23% of immature pectorosternal feathers were positive during the acute infection period; oropharyngeal swabs had slightly higher positivity during early infection, while feathers performed better during late infection. Our results indicate that immature feathers are an alternative sample for the diagnosis of HPAI in chickens and ducks. © 2015 The Author(s).

  15. Canine Skin and Conjunctival Swab Samples for the Detection and Quantification of Leishmania infantum DNA in an Endemic Urban Area in Brazil

    Science.gov (United States)

    de Almeida Ferreira, Sidney; Leite, Rodrigo Souza; Ituassu, Leonardo Trindade; Almeida, Gregório Guilherme; Souza, Daniel Menezes; Fujiwara, Ricardo Toshio; de Andrade, Antero Silva Ribeiro; Melo, Maria Norma

    2012-01-01

    Background We evaluated kDNA PCR/hybridization and quantitative real-time PCR (qPCR) targeting the gene of DNA polymerase of Leishmania infantum for CVL diagnosis and assessment of parasite load in clinical samples obtained invasively and non-invasively. Methodology/Principal Findings Eighty naturally infected dogs from an endemic urban area in Brazil were used. Animals were divided into two groups based on the presence or absence of CVL clinical sings. Skin biopsies, bone marrow, blood and conjunctival swabs samples were collected and submitted to L. infantum DNA detection. In addition, anti-Leishmania antibody titers were measured by Immunofluorescence antibody test. The symptomatic dogs had increased titers compared to asymptomatic dogs (P = 0.025). The frequencies of positive results obtained by kDNA PCR/hybridization for asymptomatic and symptomatic dogs, respectively, were as follows: right conjunctiva, 77.5% and 95.0%; left conjunctiva, 75.0% and 87.5%; skin, 45.0% and 75.0%; bone marrow, 50.0% and 77.5%; and blood, 27.5% and 22.5%. In both groups, the parasite load in the skin samples was the highest (P<0.0001). The parasite loads in the conjunctival swab and bone marrow samples were statistically equivalent within each group. The parasite burden in conjunctival swabs was higher in the dogs with clinical signs than in asymptomatic dogs (P = 0.028). This same relationship was also observed in the bone marrow samples (P = 0.002). No differences in amastigotes load in the skin were detected between the groups. Conclusions The conjunctival swab is a suitable clinical sample for qualitative molecular diagnosis of CVL. The highest parasite burdens were detected in skin regardless of the presence of VL-associated clinical signs. The qPCR results emphasized the role of dogs, particularly asymptomatic dogs, as reservoirs for CVL because of the high cutaneous parasite loads. These results may help to explain the maintenance of high transmission rates and

  16. Microbiological criteria in public catering: sampling and auditing experiences in canteens and cafeterias in Piedmont

    Directory of Open Access Journals (Sweden)

    Amaranta Traversa

    2013-02-01

    Full Text Available In the period 2006-2011 six public catering establishments (3 canteens and 3 cafeterias were monitored, trough audit and sampling, in order to verify the application of good manufacturing and hygiene practices during food production, handling and serving. The compliance to microbiological food safety criteria (Listeria monocytogenes and Salmonella spp. and process hygiene criteria were investigated using ISO standards for microbiological analyses. A total of 612 samples were collected: 192 food samples and 288 environmental swab samples from canteens; 33 food samples and 99 swab samples from cafeterias. Regarding food safety, two samples were in disagreement with criteria fixed in EU Regulation as Listeria monocytogenes was isolated from a turkey breast in a canteen and from a sandwich in a cafeteria. Regarding process hygiene criteria, as no microbiological limits are legally defined for catering services, for this study limits were fixed according to the quality standards of tender, scientific literature and laboratory experience. 23.4% foodstuffs and 8.7% swabs resulted non-compliant in canteens; 48.5% foodstuffs and 6.1% swabs resulted non-compliant in cafeterias. The count of coagulase-positive staphylococci (CPS was higher of the fixed limits in raw turkey meat and in cooked spinach: the presence among CPS of S. aureus was confirmed, strains were not able to produce enterotoxins. The most common non-compliance in hygiene criteria was represented by aerobic colony count (60.7% of total non-compliance in canteens and 75.0% in cafeterias and coliform bacteria (20.3% in canteens and 25.0% in cafeterias. Nine raw foods or raw readyto- eat food samples were non-compliant for both coliform bacteria and aerobic count; one sample (raw turkey meat was non-compliant for CPS and aerobic count but resulted to be compliant after cooking. Auditing and sampling are the most effective tools to improve food quality standard and to enhance food business

  17. Microbial profiling of cpn60 universal target sequences in artificial mixtures of vaginal bacteria sampled by nylon swabs or self-sampling devices under different storage conditions.

    Science.gov (United States)

    Schellenberg, John J; Oh, Angela Yena; Hill, Janet E

    2017-05-01

    The vaginal microbiome is increasingly characterized by deep sequencing of universal genes. However, there are relatively few studies of how different specimen collection and sample storage and processing influence these molecular profiles. Here, we evaluate molecular microbial community profiles of samples collected using the HerSwab™ self-sampling device, compared to nylon swabs and under different storage conditions. In order to minimize technical variation, mixtures of 11 common vaginal bacteria in simulated vaginal fluid medium were sampled and DNA extracts prepared for massively parallel sequencing of the cpn60 universal target (UT). Three artificial mixtures imitating commonly observed vaginal microbiome profiles were easily distinguished and proportion of sequence reads correlated with the estimated proportion of the organism added to the artificial mixtures. Our results indicate that cpn60 UT amplicon sequencing quantifies the proportional abundance of member organisms in these artificial communities regardless of swab type or storage conditions, although some significant differences were observed between samples that were stored frozen and thawed prior to DNA extraction, compared to extractions from samples stored at room temperature for up to 7days. Our results indicate that an on-the-market device developed for infectious disease diagnostics may be appropriate for vaginal microbiome profiling, an approach that is increasingly facilitated by rapidly dropping deep sequencing costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Non-Invasive Strategy for Neonatal Alloimmune Thrombocytopenia Diagnosis: Newborn Platelet Genotyping with Buccal Swabs

    Directory of Open Access Journals (Sweden)

    Gérald Bertrand

    2016-07-01

    Full Text Available Neonatal alloimmune thrombocytopenia results from the maternal immune response against fetal-specific antigens inherited from the father. The diagnosis is ascertained only when the maternal alloantibody and the offending antigen present in the newborn are identified. Up until now most laboratories perform DNA extraction for neonatal genotyping from newborn blood samplings. In order to avoid such an invasive procedure, two protocols of DNA extraction from buccal swabs were developed: a manual protocol using the QIAamp mini blood kit (Qiagen, and an automated procedure with the MagNA Pure Compact instrument (Roche. Both EDTA-blood and buccal swabs from thrombocytopenic newborns were genotyped manually (14 samples, automatically (15 samples or both manually and automatically (two samples. Human Platelet Antigen (HPA genotyping was performed using the BeadChip assay (BioArray, Immucor. Concordant genotypings were obtained for all samples except for one swab with the manual method. The automated DNA extraction from newborn buccal swabs with the MagNA Pure Compact instrument was chosen as the first-line strategy, with a significant gain of time in processing buccal swabs.

  19. Isolation and identification of female DNA on postcoital penile swabs.

    Science.gov (United States)

    Cina, S J; Collins, K A; Pettenati, M J; Fitts, M

    2000-06-01

    After sexual assault, cells originating from the assailant may be recovered from the victim. Through polymerase chain reaction (PCR)-based technology, positive scientific identification of the assailant may be made from these cells. Described is a prospective study describing a method for positively identifying cells from a female sex partner obtained from postcoital swabs of the penis of the male sex partner. Swabs were taken from the penis of a man at 1- to 24-hour intervals after coitus. DNA was isolated from each swab through standard organic extraction methods. The presence of female DNA was detected using the gender-specific amelogenin marker. Extracted DNA was amplified for eight different genetic loci using the Promega PowerPlex kit (Promega) and Amplitaq Gold (Perkin Elmer). Amplified samples were electrophoresed on precast sequencing gels (Hitachi) and were analyzed fluorescently using Hitachi's FMBIO 2 fluorescent scanner and software. Each sample obtained from a penile swab or condom was compared to male and female buccal controls. Female DNA was isolated from all postcoital penile swabs as determined by exclusive amplification of the X-chromosome specific 212 base pair amelogenin marker. In all cases, scientific identification of the female DNA from the swabs was determined by coamplification of eight STR loci (PowerPlex) and was compared to female and male control profiles. Cells shed from a female victim during sexual intercourse can be retrieved from the penis of a male offender after sexual intercourse during a 1- to 24-hour postcoital interval. DNA can be extracted from these cells and can be used to scientifically identify the female sexual participant through PCR-based technology. It is suggested that penile swabs be taken from alleged perpetrators of sexual assaults to associate them with a female victim.

  20. Elution of Artificial Sputum from Swab by Rotating Magnetic Field-Induced Mechanical Impingement

    Directory of Open Access Journals (Sweden)

    Shubham Banik

    2017-12-01

    Full Text Available Cotton-tipped applicator swabs are used as a collection device for many biological samples and its complete elution is a desired step for clinical and forensic diagnostics. Swabs are used to collect infectious body fluids, where the concentration of pathogens can range from 1 × 104 CFU/mL (colony forming units/mL in respiratory-tract infections and 1 × 105 in urinary-tract infections, to up to 1 × 109 CFU/mL in salivary samples. These samples are then eluted and lysed, prior to DNA (De-oxy Ribonucleic Acid analysis. The recovery of micro-organisms from a matrix of swab fibres depends on the nature of the body fluid, the type of the swab fibres, and the process of elution. Various methods to elute samples from swab include chemical digestion of fibres (~20% recovery, centrifugation (~58% recovery, piezoelectric vibration, or pressurized fluid-flow (~60% recovery. This study reports a magnetically-actuated physical impingement method for elution and recovery of artificial sputum samples from cotton fibres. A device has been fabricated to induce a rotating magnetic field on smaller magnetic particles in a vial that strikes the swab within a confined gap. Elution from the swab in this device was characterized using 2% Methyl cellulose in deionised water, loaded with fluorescent-tagged polystyrene beads and E. coli at various concentrations. The recovery efficiency was found to increase with both rotational speed and elution time, but plateaus after 400 RPM (Revolutions per minute and 120 s, respectively. At a higher concentration of polystyrene beads (5 × 108 particles/mL, a maximum recovery of ~85% was achieved. With lower concentration, (1 × 105 particles/mL the maximum efficiency (~92.8% was found to be almost twice of passive elution (46.7%. In the case of E. coli, the corresponding recovery efficiency at 3.35 × 105 CFU/mL is 90.4% at 500 RPM and 120 s. This elution method is expected to have a wide applicability in clinical diagnostics.

  1. Nested-PCR for the detection of Mycoplasma hyopneumoniae in bronchial alveolar swabs, frozen tissues and formalin-fixed paraffin-embedded swine lung samples: comparative evaluation with immunohistochemical findings and histological features

    Directory of Open Access Journals (Sweden)

    Paula R. Almeida

    2012-08-01

    Full Text Available The diagnosis of Mycoplasma hyopneumoniae infection is often performed through histopathology, immunohistochemistry (IHC and polymerase chain reaction (PCR or a combination of these techniques. PCR can be performed on samples using several conservation methods, including swabs, frozen tissue or formalin-fixed and paraffin-embedded (FFPE tissue. However, the formalin fixation process often inhibits DNA amplification. To evaluate whether M. hyopneumoniae DNA could be recovered from FFPE tissues, 15 lungs with cranioventral consolidation lesions were collected in a slaughterhouse from swine bred in herds with respiratory disease. Bronchial swabs and fresh lung tissue were collected, and a fragment of the corresponding lung section was placed in neutral buffered formalin for 48 hours. A PCR assay was performed to compare FFPE tissue samples with samples that were only refrigerated (bronchial swabs or frozen (tissue pieces. M. hyopneumoniae was detected by PCR in all 15 samples of the swab and frozen tissue, while it was detected in only 11 of the 15 FFPE samples. Histological features of M. hyopneumoniae infection were presented in 11 cases and 7 of these samples stained positive in IHC. Concordance between the histological features and detection results was observed in 13 of the FFPE tissue samples. PCR was the most sensitive technique. Comparison of different sample conservation methods indicated that it is possible to detect M. hyopneumoniae from FFPE tissue. It is important to conduct further research using archived material because the efficiency of PCR could be compromised under these conditions.

  2. Pilot study of participant-collected nasal swabs for acute respiratory infections in a low-income, urban population

    Directory of Open Access Journals (Sweden)

    Vargas CY

    2016-01-01

    Full Text Available Celibell Y Vargas,1 Liqun Wang,1 Yaritza Castellanos de Belliard,1 Maria Morban,1 Hilbania Diaz,1 Elaine L Larson,2,3 Philip LaRussa,1 Lisa Saiman,1,4 Melissa S Stockwell1,5,6 1Department of Pediatrics, 2School of Nursing, 3Department of Epidemiology, Mailman School of Public Health, Columbia University, 4Department of Infection Prevention and Control, NewYork-Presbyterian Hospital, 5Department of Population and Family Health, Mailman School of Public Health, Columbia University, 6NewYork-Presbyterian Hospital, New York, NY, USA Objective: To assess the feasibility and validity of unsupervised participant-collected nasal swabs to detect respiratory pathogens in a low-income, urban minority population. Methods: This project was conducted as part of an ongoing community-based surveillance study in New York City to identify viral etiologies of acute respiratory infection. In January 2014, following sample collection by trained research assistants, participants with acute respiratory infection from 30 households subsequently collected and returned a self-collected/parent-collected nasal swab via mail. Self/parental swabs corresponding with positive reverse transcription polymerase chain reaction primary research samples were analyzed. Results: Nearly all (96.8%, n=30/31 households agreed to participate; 100% reported returning the sample and 29 were received (median time: 8 days. Most (18; 62.1% of the primary research samples were positive. For eight influenza-positive research samples, seven (87.5% self-swabs were also positive. For ten other respiratory pathogen-positive research samples, eight (80.0% self-swabs were positive. Sensitivity of self-swabs for any respiratory pathogen was 83.3% and 87.5% for influenza, and specificity for both was 100%. There was no relationship between level of education and concordance of results between positive research samples and their matching participant swab. Conclusion: In this pilot study, self-swabbing

  3. Evaluation of methods to improve the extraction and recovery of DNA from cotton swabs for forensic analysis.

    Science.gov (United States)

    Adamowicz, Michael S; Stasulli, Dominique M; Sobestanovich, Emily M; Bille, Todd W

    2014-01-01

    Samples for forensic DNA analysis are often collected from a wide variety of objects using cotton or nylon tipped swabs. Testing has shown that significant quantities of DNA are retained on the swab, however, and subsequently lost. When processing evidentiary samples, the recovery of the maximum amount of available DNA is critical, potentially dictating whether a usable profile can be derived from a piece of evidence or not. The QIAamp DNA Investigator extraction kit was used with its recommended protocol for swabs (one hour incubation at 56°C) as a baseline. Results indicate that over 50% of the recoverable DNA may be retained on the cotton swab tip, or otherwise lost, for both blood and buccal cell samples when using this protocol. The protocol's incubation time and temperature were altered, as was incubating while shaking or stationary to test for increases in recovery efficiency. An additional step was then tested that included periodic re-suspension of the swab tip in the extraction buffer during incubation. Aliquots of liquid blood or a buccal cell suspension were deposited and dried on cotton swabs and compared with swab-less controls. The concentration of DNA in each extract was quantified and STR analysis was performed to assess the quality of the extracted DNA. Stationary incubations and those performed at 65°C did not result in significant gains in DNA yield. Samples incubated for 24 hours yielded less DNA. Increased yields were observed with three and 18 hour incubation periods. Increases in DNA yields were also observed using a swab re-suspension method for both cell types. The swab re-suspension method yielded an average two-fold increase in recovered DNA yield with buccal cells and an average three-fold increase with blood cells. These findings demonstrate that more of the DNA collected on swabs can be recovered with specific protocol alterations.

  4. The Use of Multiplex PCR to Determine the Prevalence of Enterotoxigenic Staphylococcus aureus Isolated from Raw Milk, Feta Cheese, and Hand Swabs.

    Science.gov (United States)

    Zeinhom, Mohamed M A; Abdel-Latef, Gihan K; Jordan, Kieran

    2015-12-01

    Staphylococcus aureus (S. aureus) can cause mastitis in cattle and, therefore, can be present in milk. This study was undertaken to determine the prevalence of coagulase positive S. aureus and its enterotoxin genes sea, seb, and sec in isolates recovered from raw milk, feta cheese, and human hand swabs of milk and cheese handlers in Beni-Suef province, Egypt. A total of 100 samples of raw milk and 50 samples of pasteurized-milk feta cheese were collected. In addition, 50 hand swabs from milk handlers and 25 hand swabs from cheese handlers were examined for the presence of coagulase positive S. aureus. The isolates were characterized by multiplex PCR for detection of sea, seb, and sec genes, and for resistance to 5 classes of commonly used antibiotics. Twelve (12/100), 12 (6/50), and 17% (13/75) of milk, cheese, and hand swab samples, respectively, were positive for coagulase positive S. aureus. One isolate was obtained from each positive sample (31 isolates), and none contained genes for SEA or SEC production. Twenty-five percent, 33%, and 31%, respectively, of the isolates contained the genes for SEB, resulting in 3%, 4%, and 5% of samples being positive for toxin producing coagulase positive S. aureus, respectively. At least one isolate was resistant to each of the antibiotics tested. Despite the low potential for SEB production shown, preventative measures, such as maintenance of the cold-chain and good hygienic practices should be implemented to further reduce the potential risk to public health from SEB, and to reduce the spread of antimicrobial resistance. © 2015 Institute of Food Technologists®

  5. Nose swabs and urinalysis as indicators of exposure to I-131

    Energy Technology Data Exchange (ETDEWEB)

    Barrall, R. C.

    1963-06-15

    During a maintenance operation on the Aromour Research Reactor, a heat lamp, which was drying a valve, caused a small quantity of I/sup 131/ become airborne. A continuous air monitor sampling in the area gave the alarm and the area ntified by the use of a 256 channel analyzer. Nose swabs of the personnel involved were taken and 24 hour urine samples were obtained. A single channel analyzer was set up, calibrated for I/sup 131/ and thyroid counts were started several hours after the incident. The thyroid count rose during the first 24 hour period and then declined closely following the 8 day half life of I/sup 131/. The urine Samples were analyzed by two different gamma counting techniques. Portions of the 24 hour urine sample were also sent to a commercial urinalysis service and analysis for I/sup 131/specifically requested. The results of the commercial service in this instance appeared to be poor. Nose swabs taken immediately after the incident were analyzed using a NaI well crystal. The average value of the ratio mu c on nose swabs to mu c in thyroid was found to be 2.6 x 1-/sup -1/ with all values within a factor of 6. The average value of the ratio mu c in 24 hour urine sample to mu c in thyroid was 5.7 with all values within a factor of 2. It would appear that at short times after a suspected exposure to I/sup 131/ nose swabs and urine samples are both useful in making a rapid assessment of exposure. The data presented are based on 10 subjects. (auth)

  6. Self-collected mid-turbinate swabs for the detection of respiratory viruses in adults with acute respiratory illnesses.

    Directory of Open Access Journals (Sweden)

    Oscar E Larios

    Full Text Available BACKGROUND: The gold standard for respiratory virus testing is a nasopharyngeal (NP swab, which is collected by a healthcare worker. Midturbinate (MT swabs are an alternative due to their ease of collection and possible self-collection by patients. The objective of this study was to compare the respiratory virus isolation of flocked MT swabs compared to flocked NP swabs. METHODS: Beginning in October 2008, healthy adults aged 18 to 69 years were recruited into a cohort and followed up for symptoms of influenza. They were asked to have NP and MT swabs taken as soon as possible after the onset of a fever or two or more respiratory symptoms with an acute onset. The swabs were tested for viral respiratory infections using Seeplex® RV12 multiplex PCR detection kit. Seventy six pairs of simultaneous NP and MT swabs were collected from 38 symptomatic subjects. Twenty nine (38% of these pairs were positive by either NP or MT swabs or both. Sixty nine (91% of the pair results were concordant. Two samples (3% for hCV OC43/HKU1 and 1 sample (1% for rhinovirus A/B were positive by NP but negative by MT. One sample each for hCV 229E/NL63, hCV OC43/HKU1, respiratory syncytial virus A, and influenza B were positive by MT but negative by NP. CONCLUSIONS: Flocked MT swabs are sensitive for the diagnosis of multiple respiratory viruses. Given the ease of MT collection and similar results between the two swabs, it is likely that MT swabs should be the preferred method of respiratory cell collection for outpatient studies. In light of this data, larger studies should be performed to ensure that this still holds true and data should also be collected on the patient preference of collection methods.

  7. Evaluation of methods to improve the extraction and recovery of DNA from cotton swabs for forensic analysis.

    Directory of Open Access Journals (Sweden)

    Michael S Adamowicz

    Full Text Available Samples for forensic DNA analysis are often collected from a wide variety of objects using cotton or nylon tipped swabs. Testing has shown that significant quantities of DNA are retained on the swab, however, and subsequently lost. When processing evidentiary samples, the recovery of the maximum amount of available DNA is critical, potentially dictating whether a usable profile can be derived from a piece of evidence or not. The QIAamp DNA Investigator extraction kit was used with its recommended protocol for swabs (one hour incubation at 56°C as a baseline. Results indicate that over 50% of the recoverable DNA may be retained on the cotton swab tip, or otherwise lost, for both blood and buccal cell samples when using this protocol. The protocol's incubation time and temperature were altered, as was incubating while shaking or stationary to test for increases in recovery efficiency. An additional step was then tested that included periodic re-suspension of the swab tip in the extraction buffer during incubation. Aliquots of liquid blood or a buccal cell suspension were deposited and dried on cotton swabs and compared with swab-less controls. The concentration of DNA in each extract was quantified and STR analysis was performed to assess the quality of the extracted DNA. Stationary incubations and those performed at 65°C did not result in significant gains in DNA yield. Samples incubated for 24 hours yielded less DNA. Increased yields were observed with three and 18 hour incubation periods. Increases in DNA yields were also observed using a swab re-suspension method for both cell types. The swab re-suspension method yielded an average two-fold increase in recovered DNA yield with buccal cells and an average three-fold increase with blood cells. These findings demonstrate that more of the DNA collected on swabs can be recovered with specific protocol alterations.

  8. Outbreak of Staphylococcal food poisoning due to SEA-producing Staphylococcus aureus.

    Science.gov (United States)

    Johler, Sophia; Tichaczek-Dischinger, Petra S; Rau, Jörg; Sihto, Henna-Maria; Lehner, Angelika; Adam, Maja; Stephan, Roger

    2013-09-01

    In 2008, 150 people gathered for a wedding celebration in Baden-Württemberg, Germany. Three hours after ingestion of a variety of foods including pancakes filled with minced chicken, several guests exhibited symptoms of acute gastroenteritis such as vomiting, diarrhea, fever, and ague. Twelve guests were reported to have fallen ill, with nine of these seeking medical care in hospitals. At least four patients were admitted to the hospital and received inpatient treatment, among them a 2-year-old child and a woman in the 4th month of pregnancy. Within 24 h of the event, an investigative team collected a variety of samples including refrigerated leftovers, food in the storage unit of the caterer, nasal swabs of the caterer, as well as 21 environmental swabs. Five stool samples from patients were provided by the hospitals. Staphylococcus aureus isolates were gathered from eight samples, among them nasal swabs of the caterer, food samples, and one stool sample. Fourier transform-infrared spectroscopy was used for species identification and for primary clustering of the isolates in a similarity tree. The isolates were further characterized by spa typing and pulsed-field gel electrophoresis, and a DNA microarray was used to determine the presence/absence of genes involved in virulence and antimicrobial resistance. We were able to match an enterotoxigenic strain from the stool sample of a patient to isolates of the same strain obtained from food and the nasal cavity of a food handler. The strain produced the enterotoxin SEA and the toxic shock syndrome toxin-1, and was also found to exhibit the genes encoding enterotoxins SEG and SEI, as well as the enterotoxin gene cluster egc. This is one of only a few studies that were able to link a staphylococcal food poisoning outbreak to its source.

  9. Evaluation of a new T2 Magnetic Resonance assay for rapid detection of emergent fungal pathogen Candida auris on clinical skin swab samples.

    Science.gov (United States)

    Sexton, D Joseph; Bentz, Meghan L; Welsh, Rory M; Litvintseva, Anastasia P

    2018-06-25

    Candida auris is a multidrug-resistant pathogenic yeast whose recent emergence is of increasing public-health concern. C. auris can colonize multiple body sites, including patients' skin, and survive for weeks in the healthcare environment, facilitating patient-to-patient transmission and fueling healthcare-associated outbreaks. Rapid and accurate detection of C. auris colonization is essential for timely implementation of infection control measures and prevent transmission. Currently, axilla/groin composite swabs, used to assess colonization status, are processed using a culture-based method that is sensitive and specific but requires 14 days. This delay limits the opportunity to respond and highlights the need for a faster alternative. The culture-independent T2 Magnetic Resonance (T2MR) system is a rapid diagnostic platform shown to detect target pathogens of interest from unprocessed blood samples in T2 assay was evaluated for screening of the skin surveillance samples. Inclusivity and limit of detection of the T2 C. auris assay were assessed with spiked samples in a representative skin flora background. The T2 C. auris assay recognized isolates from each of the 4 known clades of C. auris and consistently detected cells at 5 CFU/mL. Finally, 89 clinical axilla/groin swab samples were processed with the T2 C. auris assay. The culture-based diagnostic assay was used as a gold standard to determine performance statistics including sensitivity (0.89) and specificity (0.98). Overall, the T2 C. auris assay performed well as a rapid diagnostic and could help expedite the detection of C. auris in patient skin swabs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Quantification of loosely associated and tightly associated bacteria on broiler carcass skin using swabbing, stomaching, and grinding methods.

    Science.gov (United States)

    Singh, P; Lee, H C; Chin, K B; Ha, S D; Kang, I

    2015-12-01

    This research was conducted to quantify bacterial populations after swabbing or stomaching, followed by grinding the swabbed or stomached broiler skins. For each of 3 replications, 3 eviscerated broilers were randomly taken from a processing line in a local broiler processing plant. Ten swabs and 10 stomachs per bird were conducted on the left- and the right-side skins (10×7 cm), respectively, which were then finally ground. Results indicated that mesophilic aerobic bacteria (MAB) in the first swabbed sample were significantly lower than those in the first stomached sample (P0.05). During 10 swabbings followed by final grinding, 8, 9, and 83% of MAB were detected after the first swabbing, after the second through 10th swabbings, and after final grinding of the skin, respectively. During 10 stomachings followed by the final grinding, 17, 18, and 65% of MAB were detected after the first stomaching, after the second through 10th stomachings, and after final grinding of the skin, respectively. Escherichia coli (E. coli) and coliforms were significantly higher in the first stomaching than those in the first swabbing (P0.05). Populations of E. coli and coliforms decreased step-wisely from the highest after grinding to the intermediate after first and second sampling, and to the least after 10th sampling (Pgrinding. In this study, less than 35% of MAB seemed loosely associated in the skin of eviscerated broiler, whereas more than 65% of MAB looked tightly associated, which were not recovered by stomaching or swabbing even 10 times but were recovered by grinding the skin. © 2015 Poultry Science Association Inc.

  11. FLOQSwabTM: optimisation of procedures for the recovery of microbiological samples from surfaces

    Directory of Open Access Journals (Sweden)

    Guido Finazzi

    2016-08-01

    Full Text Available The FLOQSwabTM is a specimen collection device worldwide recognised for its superior performance in the clinical diagnostics. The aim of this work was to evaluate FLOQSwabTM for the recovery of microbiological samples from surfaces compared to the traditional swab (rayon tipped swab as per ISO 18593:2004 standard. The FLOQSwabTM, thanks to its innovative manufacturing technology, allows improving the efficiency of recovery and release of analyte. The study has been divided into two experiments. In the first experiment the two swabs were evaluated for their capacity to recover and release the analyte (three different bacterial loads of Escherichia coli. In the second experiment, the two swabs were evaluated for their capacity to recover three different bacterial loads of E. coli from two different surface materials (stainless steel and polypropylene. In all experiments the flocked swab demonstrated a higher recovery rate compared to the traditional rayon tipped swab. The data obtained from this preliminary study demonstrated that the FLOQSwabTM could be a good food surfaces collection device, which improves the recovery of the analyte and thus produces accurate results. Based on the outcomes of the study, a larger field study is in progress using the FLOQSwabTM for samples collection to improve both environmental monitoring and the efficacy of the hygiene controls for food safety.

  12. Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.

    Science.gov (United States)

    Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E

    2018-02-20

    Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2  > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time q

  13. Comparison of automated processing of flocked swabs with manual processing of fiber swabs for detection of nasal carriage of Staphylococcus aureus.

    Science.gov (United States)

    Jones, Gillian; Matthews, Roger; Cunningham, Richard; Jenks, Peter

    2011-07-01

    The sensitivity of automated culture of Staphylococcus aureus from flocked swabs versus that of manual culture of fiber swabs was prospectively compared using nasal swabs from 867 patients. Automated culture from flocked swabs significantly increased the detection rate, by 13.1% for direct culture and 10.2% for enrichment culture.

  14. Identification and genotyping of molluscum contagiosum virus from genital swab samples by real-time PCR and Pyrosequencing.

    Science.gov (United States)

    Trama, Jason P; Adelson, Martin E; Mordechai, Eli

    2007-12-01

    Laboratory diagnosis of molluscum contagiosum virus (MCV) is important as lesions can be confused with those caused by Cryptococcus neoformans, herpes simplex virus, human papillomavirus, and varicella-zoster virus. To develop a rapid method for identifying patients infected with MCV via swab sampling. Two dual-labeled probe real-time PCR assays, one homologous to the p43K gene and one to the MC080R gene, were designed. The p43K PCR was designed to be used in conjunction with Pyrosequencing for confirmation of PCR products and discrimination between MCV1 and MCV2. Both PCR assays were optimized with respect to reaction components, thermocycling parameters, and primer and probe concentrations. The specificities of both PCR assays were confirmed by non-amplification of 38 known human pathogens. Sensitivity assays demonstrated detection of as few as 10 copies per reaction. Testing 703 swabs, concordance between the two real-time PCR assays was 99.9%. Under the developed conditions, Pyrosequencing of the p43K PCR product was capable of providing enough nucleotide sequence to definitively differentiate MCV1 and MCV2. These real-time PCR assays can be used for the rapid, sensitive, and specific detection of MCV and, when combined with Pyrosequencing, can further discriminate between MCV1 and MCV2.

  15. Imperfect pathogen detection from non-invasive skin swabs biases disease inference

    Science.gov (United States)

    DiRenzo, Graziella V.; Grant, Evan H. Campbell; Longo, Ana; Che-Castaldo, Christian; Zamudio, Kelly R.; Lips, Karen

    2018-01-01

    1. Conservation managers rely on accurate estimates of disease parameters, such as pathogen prevalence and infection intensity, to assess disease status of a host population. However, these disease metrics may be biased if low-level infection intensities are missed by sampling methods or laboratory diagnostic tests. These false negatives underestimate pathogen prevalence and overestimate mean infection intensity of infected individuals. 2. Our objectives were two-fold. First, we quantified false negative error rates of Batrachochytrium dendrobatidis on non-invasive skin swabs collected from an amphibian community in El Copé, Panama. We swabbed amphibians twice in sequence, and we used a recently developed hierarchical Bayesian estimator to assess disease status of the population. Second, we developed a novel hierarchical Bayesian model to simultaneously account for imperfect pathogen detection from field sampling and laboratory diagnostic testing. We evaluated the performance of the model using simulations and varying sampling design to quantify the magnitude of bias in estimates of pathogen prevalence and infection intensity. 3. We show that Bd detection probability from skin swabs was related to host infection intensity, where Bd infections information in advance, we advocate that the most cautious approach is to assume all errors are possible and to accommodate them by adjusting sampling designs. The modeling framework presented here improves the accuracy in estimating pathogen prevalence and infection intensity.

  16. Early Results and Spaceflight Implications of the SWAB Flight Experiment

    Science.gov (United States)

    Ott, C. Mark; Pierson, Duane L.

    2007-01-01

    Microbial monitoring of spacecraft environments provides key information in the assessment of infectious disease risk to the crew. Monitoring aboard the Mir space station and International Space Station (ISS) has provided a tremendous informational baseline to aid in determining the types and concentrations of microorganisms during a mission. Still, current microbial monitoring hardware utilizes culture-based methodology which may not detect many medically significant organisms, such as Legionella pneumophila. We hypothesize that evaluation of the ISS environment using non-culture-based technologies would reveal microorganisms not previously reported in spacecraft, allowing for a more complete health assessment. To achieve this goal, a spaceflight experiment, operationally designated as SWAB, was designed to evaluate the DNA from environmental samples collected from ISS and vehicles destined for ISS. Results from initial samples indicate that the sample collection and return procedures were successful. Analysis of these samples using denaturing gradient gel electrophoresis and targeted PCR primers for fungal contaminants is underway. The current results of SWAB and their implication for in-flight molecular analysis of environmental samples will be discussed.

  17. Acceptability of study procedures (self-collected introital swabs, blood draws and stool sample collection) by students 10-16 years for an HPV vaccine effectiveness study: a pilot study.

    Science.gov (United States)

    Nakalembe, Miriam; Mutyaba, Twaha; Mirembe, Florence

    2016-03-16

    A cohort study was planned to evaluate vaccine immunogenicity and effect of malaria and helminth co-infections on the bivalent Human papilloma virus (HPV) vaccine. The study would involve self collected introital swabs, blood draws and stool sample collection. We therefore conducted a pilot study to assess the acceptability of these procedures among the students and their parents. A cross-sectional study among forty four students from two purposively selected primary schools of Western Uganda. Exit interviews and two focus group discussions (FGD) (for parents) were conducted. Acceptability was measured by willingness to undergo the procedures again, recommending the procedures to others as well as proportion of introital swabs positive for β globulin. FGD determined acceptability of the parents and explored opinions and perceptions that would influence their decisions. HPV-16/18 and β globulin deoxyribonucleic acid (DNA) were analysed using a polymerase chain reaction (PCR) kit. All the students (100%) in the study were willing to provide a self- collected introital swab and a stool sample as well as recommending their friends while (86.3%) were willing for blood draws. There were 40/44 (90.1%) self collected introital swabs that had positive result for human β globulin though none of them was positive for HPV-16/18. In the FGD, it emerged that parents concerns were on the blood draws and introital swab collection which were addressed. The study procedures were highly acceptable among this study population of students and their parents. Follow-up to assess HPV vaccine effectiveness and factors that may influence the vaccine in this age group is feasible.

  18. Comparison of Automated Processing of Flocked Swabs with Manual Processing of Fiber Swabs for Detection of Nasal Carriage of Staphylococcus aureus▿‡

    Science.gov (United States)

    Jones, Gillian; Matthews, Roger; Cunningham, Richard; Jenks, Peter

    2011-01-01

    The sensitivity of automated culture of Staphylococcus aureus from flocked swabs versus that of manual culture of fiber swabs was prospectively compared using nasal swabs from 867 patients. Automated culture from flocked swabs significantly increased the detection rate, by 13.1% for direct culture and 10.2% for enrichment culture. PMID:21525218

  19. Unlocking the story in the swab: A new genotyping assay for the amphibian chytrid fungus Batrachochytrium dendrobatidis.

    Science.gov (United States)

    Byrne, Allison Q; Rothstein, Andrew P; Poorten, Thomas J; Erens, Jesse; Settles, Matthew L; Rosenblum, Erica Bree

    2017-11-01

    One of the most devastating emerging pathogens of wildlife is the chytrid fungus, Batrachochytrium dendrobatidis (Bd), which affects hundreds of amphibian species around the world. Genomic data from pure Bd cultures have advanced our understanding of Bd phylogenetics, genomic architecture and mechanisms of virulence. However, pure cultures are laborious to obtain and whole-genome sequencing is comparatively expensive, so relatively few isolates have been genetically characterized. Thus, we still know little about the genetic diversity of Bd in natural systems. The most common noninvasive method of sampling Bd from natural populations is to swab amphibian skin. Hundreds of thousands of swabs have been collected from amphibians around the world, but Bd DNA collected via swabs is often low in quality and/or quantity. In this study, we developed a custom Bd genotyping assay using the Fluidigm Access Array platform to amplify 192 carefully selected regions of the Bd genome. We obtained robust sequence data for pure Bd cultures and field-collected skin swabs. This new assay has the power to accurately discriminate among the major Bd clades, recovering the basic tree topology previously revealed using whole-genome data. Additionally, we established a critical value for initial Bd load for swab samples (150 Bd genomic equivalents) above which our assay performs well. By leveraging advances in microfluidic multiplex PCR technology and the globally distributed resource of amphibian swab samples, noninvasive skin swabs can now be used to address critical spatial and temporal questions about Bd and its effects on declining amphibian populations. © 2017 John Wiley & Sons Ltd.

  20. Prevalence of extended-spectrum beta-lactamase-producing bacteria in food

    Directory of Open Access Journals (Sweden)

    Tham J

    2012-10-01

    Full Text Available Johan Tham,1 Mats Walder,2 Eva Melander,2,3 Inga Odenholt11Infectious Diseases Unit, Department of Clinical Sciences, 2Medical Microbiology, Department of Laboratory Medicine, Lund University, Malmö, Sweden; 3Department of Infection Control, Laboratory Medicine, Skåne County, SwedenAbstract: Extended-spectrum β-lactamase (ESBL-producing Enterobacteriaceae with Cefotaximase–München (CTX-M enzymes are rapidly increasing worldwide and pose a threat to health care. ESBLs with CTX-M enzymes have been isolated from animals and different food products, but it is unknown if food imported from the Mediterranean area may be a possible reservoir of these bacteria. During 2007–2008, swab samples from food across different retail outlets (mostly food from the Mediterranean countries and Swedish chicken were collected. Escherichia coli strains from Swedish meat and E. coli isolates from unspecified food from a Swedish food testing laboratory were also examined. In 349 of the 419 swab samples, growth of Enterobacteriaceae was found. In most of the samples, there was also growth of Gram-negative environmental bacteria. Air dry-cured products contained significantly less Enterobacteriaceae isolates compared to lettuces; however, none of the examined Enterobacteriaceae harbored ESBLs. This study did not support the theory that imported food from the Mediterranean area or Swedish domestic food might constitute an important vehicle for the dissemination of ESBL-producing Enterobacteriaceae; however, a spread from food to humans may have occurred after 2008.Keywords: ESBL, antibiotic resistance, zoonosis, food, Enterobacteriaceae

  1. Comparison of two non-invasive methods of microbial analysis in surgery practice: incision swabbing and the indirect imprint technique.

    Science.gov (United States)

    Chovanec, Zdenek; Veverkova, Lenka; Votava, Miroslav; Svoboda, Jiri; Jedlicka, Vaclav; Capov, Ivan

    2014-12-01

    A variety of methods exist to take samples from surgical site infections for cultivation; however, an unambiguous and suitable method has not yet been defined. The aim of our retrospective non-randomized study was to compare two non-invasive techniques of sampling material for microbiologic analysis in surgical practice. We compared bacteria cultured from samples obtained with the use of the swab technique, defined in our study as the gold standard, with the indirect imprint technique. A cotton-tipped swab (Copan, Brescia, Italy) was used; the imprints were taken using Whatman no. 4 filter paper (Macherey-Nagal, Duren, Germany) cut into 5×5 cm pieces placed on blood agar in a Petri dish. To culture the microorganisms in the microbiology laboratory, we used blood agar, UriSelect 4 medium (Bio-Rad, Marnes-la-Coquette, France), and a medium with sodium chloride (blood agar with salt). After careful debridement, a sample was taken from the incision surface by swab and subsequently the same area of the surface was imprinted onto filter paper. The samples were analyzed in the microbiology laboratory under standard safety precautions. The cultivation results of the two techniques were processed statistically using contingency tables and the McNemar test. Those samples that were simultaneously cultivation-positive by imprint and -negative by swabbing were processed in greater detail. Over the period between October 2008 and March 2013, 177 samples from 70 patients were analyzed. Sampling was carried out from 42 males and 28 females. One hundred forty-six samples were from incisions after operations (21 samples from six patients after operation on the thoracic cavity, 73 samples from 35 patients after operation on the abdominal cavity combined with the gastrointestinal tract, 52 samples from 19 patients with other surgical site infections not included above) and 31 samples from 11 patients with no post-operative infection. One patient had a sample taken both from a post

  2. Sperm cell purification from mock forensic swabs using SOMAmer™ affinity reagents.

    Science.gov (United States)

    Katilius, Evaldas; Carmel, Andrew B; Koss, Heidi; O'Connell, Dan; Smith, Breanna C; Sanders, Glenn M; LaBerge, Greggory S

    2018-03-27

    We have demonstrated a proof of concept with affinity-based purification of sperm cells from mock forensic samples using SOMAmer™ reagents, DNA-based affinity reagents developed by SomaLogic, Inc. SOMAmer reagents were selected in vitro using whole-cell SELEX to bind specifically with intact, detergent-treated sperm cells. Successful separation of sperm from epithelial cells and their debris was demonstrated using buccal swabs with added semen. Primarily male DNA profiles were generated from sperm cells eluted from the types of cotton swabs typically used for rape kit evidence collection. The quality of sperm DNA isolated from samples purified using SOMAmers is comparable to existing commercially available differential extraction-based methods at higher sperm concentrations. This purification method is simple, offers relatively rapid (forensic casework. Copyright © 2018. Published by Elsevier B.V.

  3. Skin swabs with FTA® cards as a dry storage source for amphibian DNA

    OpenAIRE

    Ward, A; Hide, G; Jehle, R

    2018-01-01

    Amphibians are the most endangered group of vertebrates, and conservation measures increasingly rely on information drawn from genetic markers. The present study explores skin swabs with Whatman FTA® cards as a method to retrieve PCR-amplifiable amphibian DNA. Swabs from ten adult great crested newts (Triturus cristatus) were used to compare FTA® card-based protocols with tissue sampling based on toe clips. PCR success rates were measured for seven microsatellite markers and one mtDNA marker ...

  4. Food hygiene control in school canteens of La Spezia municipality: years 2003-2012

    Directory of Open Access Journals (Sweden)

    Carlo Ercolini

    2013-04-01

    Full Text Available The school canteens are public catering services of great interest as they provide meals to a high number of consumers who are particularly susceptible to health risks, therefore surveillance and health control are very important to ensure food safety. To this purpose, a convention between the Istituto Zooprofilattico Sperimentale of Piemonte Liguria e Valle d’Aosta, and La Spezia municipality was established for the health control of school canteens. In this article we report the results of analysis performed on food and swab surfaces samples collected during the period 2003-2012 in 22 school canteens and 3 cooking centers. From a total of 1187 samples: 313 raw foods were analyzed for chemical and microbiological parameters to verify compliance with legislation, 71 food preparations were analyzed for bacteria indicators to assess the good manufacturing practices, and 803 surface swabs were tested for total mesophilic count (TMC, Salmonella spp. and Listeria spp. to control cleaning/disinfection conditions. The results show that only 1.3% of raw food samples did not respect the limits imposed by legislation, and 1.4% of food preparations was positive for pathogens. In environmental swabs, pathogenic microorganisms were never isolated and TMC exceeded the limits of acceptability in no more than 27% of cases. The most contaminated surfaces were those in contact with food and the equipment difficult to clean. The results demonstrate that potential hazards are kept to acceptable levels in school canteens and cooking centers investigated. In fact, during the period considered no foodborne diseases were reported among users. However, data obtained may be useful to better define control measures to be adopted to improve the hygienic level production in these structures and to prevent foodborne infections.

  5. Buccal DNA collection: comparison of buccal swabs with FTA cards.

    Science.gov (United States)

    Milne, Elizabeth; van Bockxmeer, Frank M; Robertson, Laila; Brisbane, Joanna M; Ashton, Lesley J; Scott, Rodney J; Armstrong, Bruce K

    2006-04-01

    Collection and analysis of DNA, most commonly from blood or buccal cells, is becoming more common in epidemiologic studies. Buccal samples, which are painless to take and relatively easily collected, are often the preferred source. There are several buccal cell collection methods: swabs, brushes, mouthwash, and treated cards, such as FTA or IsoCode cards. Few studies have systematically compared methods of buccal cell collection with respect to DNA yield and amplification success under similar conditions. We compared buccal DNA collection and amplification using buccal swabs and FTA cards in 122 control subjects from our Australian case-control study of childhood acute lymphoblastic leukaemia. Buccal DNA was quantified using a real-time PCR for beta-actin and genotyped at the loci of three polymorphisms (MTHFR 677C>T, ACE I/D, and XPD 1012G>A). PCR was successful with DNA from buccal swabs for 62% to 89% of subjects and from FTA cards for 83% to 100% of subjects, depending on the locus. The matched pair odds ratios (95% confidence interval) comparing success of FTA cards with buccal swabs are as follows: MTHFR 677C>T using PCR-RFLP, 12.5 (11.6-13.5) and using real-time PCR, 130.0 (113.1-152.8); ACE I/D using PCR-amplified fragment length polymorphism, 3.36 (3.2-3.5); XPD 1012G>A using real-time PCR, 150.0 (132.7-172.3). FTA cards are a robust DNA collection method and generally produce DNA suitable for PCR more reliably than buccal swabs. There are, however, technical challenges in handling discs punched from FTA cards that intending users should be aware of.

  6. 'Swab racks are an old fashioned idea'.

    Science.gov (United States)

    Mumford, M

    1991-12-01

    Mary Mumford, theatre sister at the Princes of Wales Hospital, Bridgend, was asked to speak in a short debate at an NATN branch meeting, supporting the motion that 'swab racks are an old fashioned idea'. Although she did not like swab racks she had not attempted thus far to do anything about them. In the event, she actually lost the debate--not in principle but because she could offer no effective alternative method of checking swabs. Having been given the incentive, a trial is now being conducted in her hospital similar to that described by Paul Wicker. This is the case presented by Mary Mumford supporting the following motion ... 'that swab racks are an old fashioned idea, which cause more potential problems due to exposure of blood than is proven to be safe in today's theatre environment'.

  7. [Carriage of Staphylococcus aureus among food service workers].

    Science.gov (United States)

    Alarcón-Lavín, María Paula; Oyarzo, Carolina; Escudero, Carlos; Cerda-Leal, Fabiola; Valenzuela, Francisco J

    2017-12-01

    Background Staphylococcus aureus produces 11 serotypes of endotoxins that may cause food poisoning. Aim To determine the prevalence of type A enterotoxigenic Staphylococcus aureus carriage among food service workers in Chillan, Chile. Material and Methods Pharyngeal swabs were obtained from 100 food service workers and were cultured in Agar plates. After identifying the presence of Staphylococcus aureus, DNA was extracted to identify type A toxin by conventional PCR. Results Thirty eight percent of samples were colonized with Staphylococcus aureus. Among these, 26% were toxin A producers. Conclusions Half of the sampled workers carried Staphylococcus aureus and a quarter of these produced type A enterotoxin.

  8. Commutability of food microbiology proficiency testing samples.

    Science.gov (United States)

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013

  9. Swabbing often fails to detect amphibian Chytridiomycosis under conditions of low infection load.

    Directory of Open Access Journals (Sweden)

    Jaehyub Shin

    Full Text Available The pathogenic chytrid fungus, Batrachochytrium dendrobatidis (denoted Bd, causes large-scale epizootics in naïve amphibian populations. Intervention strategies to rapidly respond to Bd incursions require sensitive and accurate diagnostic methods. Chytridiomycosis usually is assessed by quantitative polymerase chain reaction (qPCR amplification of amphibian skin swabs. Results based on this method, however, sometimes yield inconsistent results on infection status and inaccurate scores of infection intensity. In Asia and other regions where amphibians typically bear low Bd loads, swab results are least reliable. We developed a Bd-sampling method that collects zoospores released by infected subjects into an aquatic medium. Bd DNA is extracted by filters and amplified by nested PCR. Using laboratory colonies and field populations of Bombina orientalis, we compare results with those obtained on the same subjects by qPCR of DNA extracted from swabs. Many subjects, despite being diagnosed as Bd-negative by conventional methods, released Bd zoospores into collection containers and thus must be considered infected. Infection loads determined from filtered water were at least 1000 times higher than those estimated from swabs. Subjects significantly varied in infection load, as they intermittently released zoospores, over a 5-day period. Thus, the method might be used to compare the infectivity of individuals and study the periodicity of zoospore release. Sampling methods based on water filtration can dramatically increase the capacity to accurately diagnose chytridiomycosis and contribute to a better understanding of the interactions between Bd and its hosts.

  10. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture.

    Science.gov (United States)

    Hutchison, J R; Piepel, G F; Amidan, B G; Hess, B M; Sydor, M A; Deatherage Kaiser, B L

    2018-05-01

    We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD 95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD 95 results. Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD 95 was lowest for glass and highest for vinyl tile. LOD 95 values overall were lower for mRV-PCR than for the culture method. This study adds to the limited data on FNR and LOD 95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis. © 2018 The Society for Applied Microbiology.

  11. Performance of swabs, lavage, and diluents to quantify biomarkers of female genital tract soluble mucosal mediators.

    Directory of Open Access Journals (Sweden)

    Charlene S Dezzutti

    Full Text Available BACKGROUND: Measurement of immune mediators and antimicrobial activity in female genital tract secretions may provide biomarkers predictive of risk for HIV-1 acquisition and surrogate markers of microbicide safety. However, optimal methods for sample collection do not exist. This study compared collection methods. METHODS: Secretions were collected from 48 women (24 with bacterial vaginosis [BV] using vaginal and endocervical Dacron and flocked swabs. Cervicovaginal lavage (CVL was collected with 10 mL of Normosol-R (n = 20, saline (n = 14, or water (n = 14. The concentration of gluconate in Normosol-R CVL was determined to estimate the dilution factor. Cytokine and antimicrobial mediators were measured by Luminex or ELISA and corrected for protein content. Endogenous anti-HIV-1 and anti-E. coli activity were measured by TZM-bl assay or E. coli growth. RESULTS: Higher concentrations of protein were recovered by CVL, despite a 10-fold dilution of secretions, as compared to swab eluents. After protein correction, endocervical swabs recovered the highest mediator levels regardless of BV status. Endocervical and vaginal flocked swabs recovered significantly higher levels of anti-HIV-1 and anti-E. coli activity than Dacron swabs (P<0.001. BV had a significant effect on CVL mediator recovery. Normosol-R tended to recover higher levels of most mediators among women with BV, whereas saline or water tended to recover higher levels among women without BV. Saline recovered the highest levels of anti-HIV-1 activity regardless of BV status. CONCLUSIONS: Endocervical swabs and CVL collected with saline provide the best recovery of most mediators and would be the optimal sampling method(s for clinical trials.

  12. Interpretation of nasal swab measurements following suspected releases of actinide aerosols

    International Nuclear Information System (INIS)

    Klumpp, John Allan; Bertelli, Luiz; Waters, Tom L.

    2017-01-01

    For radionuclides such as plutonium and americium, detection of removable activity in the nose (i.e., nasal swab measurements) are frequently used to determine whether follow-up bioassay measurements are warranted following a potential intake. For this paper, the authors analyzed 429 nasal swab measurements taken following incidents or suspicious circumstances (such as an air monitor alarming) at Los Alamos National Laboratory (LANL) for which the dose was later evaluated using in vitro bioassay. Nasal swab measurements were found to be very poor predictors of dose and should not be used as such in the field. However, nasal swab measurements can be indicative of whether a reliably detectable committed effective dose (CED) occurred. About 14% of nasal swab measurements between 1.25 and 16.7 Bq corresponded to CEDs greater than 1 mSv, so in general, positive nasal swabs always indicate that follow-up bioassay should be performed (positive nasal swabs less than 1.25 Bq are considered separately). This probability increased significantly for nasal swabs greater than 16.7 Bq. Only about 3% of nasal swabs with no detectable activity (NDA) corresponded to reliably detectable CEDs. As a result, a nasal swab with NDA is therefore necessary, but not sufficient, to negate the need for a follow-up bioassay if it was collected following other workplace indicators of a potential intake.

  13. Screening of Active Lyssavirus Infection in Wild Bat Populations by Viral RNA Detection on Oropharyngeal Swabs

    Science.gov (United States)

    Echevarría, Juan E.; Avellón, Ana; Juste, Javier; Vera, Manuel; Ibáñez, Carlos

    2001-01-01

    Brain analysis cannot be used for the investigation of active lyssavirus infection in healthy bats because most bat species are protected by conservation directives. Consequently, serology remains the only tool for performing virological studies on natural bat populations; however, the presence of antibodies merely reflects past exposure to the virus and is not a valid marker of active infection. This work describes a new nested reverse transcription (RT)-PCR technique specifically designed for the detection of the European bat virus 1 on oropharyngeal swabs obtained from bats but also able to amplify RNA from the remaining rabies-related lyssaviruses in brain samples. The technique was successfully used for surveillance of a serotine bat (Eptesicus serotinus) colony involved in a case of human exposure, in which 15 out of 71 oropharyngeal swabs were positive. Lyssavirus infection was detected on 13 oropharyngeal swabs but in only 5 brains out of the 34 animals from which simultaneous brain and oropharyngeal samples had been taken. The lyssavirus involved could be rapidly identified by automatic sequencing of the RT-PCR products obtained from 14 brains and three bat oropharyngeal swabs. In conclusion, RT-PCR using oropharyngeal swabs will permit screening of wild bat populations for active lyssavirus infection, for research or epidemiological purposes, in line not only with conservation policies but also in a more efficient manner than classical detection techniques used on the brain. PMID:11574590

  14. Surface, Water, and Air Biocharacterization (SWAB) Flight Experiment

    Science.gov (United States)

    Castro, V. A.; Ott, C. M.; Pierson, D. L.

    2012-01-01

    The determination of risk from infectious disease during spaceflight missions is composed of several factors including both the concentration and characteristics of the microorganisms to which the crew are exposed. Thus, having a good understanding of the microbial ecology aboard spacecraft provides the necessary information to mitigate health risks to the crew. While preventive measures are taken to minimize the presence of pathogens on spacecraft, medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a specific culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. To address this bias in our understanding of the ISS environment, the Surface, Water, and Air Biocharacterization (SWAB) Flight Experiment was designed to investigate and develop monitoring technology to provide better microbial characterization. For the SWAB flight experiment, we hypothesized that environmental analysis using non-culture-based technologies would reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. Key findings during this experiment included: a) Generally, advanced molecular techniques were able to reveal a few organisms not recovered using culture-based methods; however, there is no indication that current monitoring is "missing" any medically significant bacteria or fungi. b) Molecular techniques have tremendous potential for microbial monitoring, however, sample preparation and data analysis present challenges for spaceflight hardware. c) Analytical results indicate that some molecular techniques, such as denaturing gradient gel electrophoresis (DGGE), can

  15. Genetic Characterization of Fungi Isolated from the Environmental Swabs collected from a Compounding Center Known to Cause Multistate Meningitis Outbreak in United States Using ITS Sequencing

    Directory of Open Access Journals (Sweden)

    Irshad M. Sulaiman

    2014-08-01

    Full Text Available A multistate fungal meningitis outbreak started in September of 2012 which spread in 20 states of the United States. The outbreak has been fatal so far, and has affected 751 individuals with 64 deaths among those who received contaminated spinal injections manufactured by a Compounding Center located in Massachusetts. In a preliminary study, Food and Drug Administration (FDA investigated the outbreak in collaboration with Centers for Disease Control and Prevention (CDC, state and local health departments, and identified four fungal and several bacterial contaminations in the recalled unopened injection vials. This follow-up study was carried out to assess DNA sequencing of the ITS1 region of rRNA gene for rapid identification of fungal pathogens during public health outbreak investigations. A total of 26 environmental swabs were collected from several locations at the manufacturing premises of the Compounding Center known to have caused the outbreak. The swab samples were initially examined by conventional microbiologic protocols and a wide range of fungal species were recovered. Species-identification of these microorganisms was accomplished by nucleotide sequencing of ITS1 region of rRNA gene. Analysis of data confirmed 14 additional fungal species in the swabs analyzed.

  16. Diagnostic herd sensitivity using environmental samples

    DEFF Research Database (Denmark)

    Vigre, Håkan; Josefsen, Mathilde Hartmann; Seyfarth, Anne Mette

    either at farm or slaughter. Three sample matrices were collected; dust samples (5 environmental swabs), nasal swabs (10 pools with 5 animals per pool) and air samples (1 filter). Based on the assumption that MRSA occurred in all 48 herds the overall herd sensitivity was 58% for nasal swabs, 33% for dust....... In our example, the prevalence of infected pigs in each herd was estimated from the pooled samples of nasal swabs. Logistic regression was used to estimate the effect of animal prevalence on the probability to detect MRSA in the dust and air samples at herd level. The results show a significant increase...

  17. Occurrence of Campylobacter spp. in raw and ready-to-eat foods and in a Canadian food service operation.

    Science.gov (United States)

    Medeiros, Diane T; Sattar, Syed A; Farber, Jeffrey M; Carrillo, Catherine D

    2008-10-01

    The occurrence of Campylobacter spp. in a variety of foods from Ottawa, Ontario, Canada, and raw milk samples from across Canada was determined over a 2-year period. The samples consisted of 55 raw foods (chicken, pork, and beef), 126 raw milk samples from raw milk cheese manufacturers, and 135 ready-to-eat foods (meat products, salads, and raw milk cheeses). Campylobacter jejuni was detected in 4 of the 316 samples analyzed: 1 raw beef liver sample and 3 raw chicken samples. An isolation rate of 9.7% was observed among the raw chicken samples tested. This study also investigated the role of cross-contamination in disseminating Campylobacter from raw poultry within a food service operation specializing in poultry dishes. Accordingly, kitchen surfaces within a restaurant in Ottawa, Ontario, were sampled between March and August 2001. Tests of the sampling method indicated that as few as 100 Campylobacter cells could be detected if sampling was done within 45 min of inoculation; however, Campylobacter spp. were not detected in 125 swabs of surfaces within the kitchens of this food service operation. Despite the reported high prevalence of Campylobacter spp. in raw poultry, this organism was not detected on surfaces within a kitchen of a restaurant specializing in poultry dishes.

  18. Characterizing the rapid spread of porcine epidemic diarrhea virus (PEDV through an animal food manufacturing facility.

    Directory of Open Access Journals (Sweden)

    Loni L Schumacher

    Full Text Available New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1 observe the magnitude of virus contamination in an animal food manufacturing facility, and 2 investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR. Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05 and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05. Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples, with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of

  19. Occurrence, Persistence, and Virulence Potential of Listeria ivanovii in Foods and Food Processing Environments in the Republic of Ireland

    Science.gov (United States)

    Morgan, Ciara A.; Hill, Colin; Gahan, Cormac G. M.; Jordan, Kieran

    2015-01-01

    The aim of this study was to assess the occurrence of L. ivanovii in foods and food processing environments in Ireland, to track persistence, and to characterize the disease causing potential of the isolated strains. A total of 2,006 samples (432 food samples and 1,574 environmental swabs) were collected between March 2013 and March 2014 from 48 food business operators (FBOs) belonging to different production sectors (dairy, fish, meat, and fresh-cut vegetable). Six of the forty-eight FBOs had samples positive for L. ivanovii on at least one sampling occasion. L. ivanovii was present in fifteen samples (fourteen environmental samples and one food sample). All but one of those positive samples derived from the dairy sector, where L. ivanovii prevalence was 1.7%. Six distinguishable pulsotypes were obtained by PFGE analysis, with one pulsotype being persistent in the environment of a dairy food business. Sequence analysis of the sigB gene showed that fourteen isolates belonged to L. ivanovii subsp. londoniensis, while only one isolate was L. ivanovii subsp. ivanovii. Cell invasion assays demonstrated that the majority of L. ivanovii strains were comparable to L. monocytogenes EGDe in their ability to invade CACO-2 epithelial cells whilst four isolates had significantly higher invasion efficiencies. PMID:26543856

  20. Occurrence, Persistence, and Virulence Potential of Listeria ivanovii in Foods and Food Processing Environments in the Republic of Ireland

    Directory of Open Access Journals (Sweden)

    Avelino Alvarez-Ordóñez

    2015-01-01

    Full Text Available The aim of this study was to assess the occurrence of L. ivanovii in foods and food processing environments in Ireland, to track persistence, and to characterize the disease causing potential of the isolated strains. A total of 2,006 samples (432 food samples and 1,574 environmental swabs were collected between March 2013 and March 2014 from 48 food business operators (FBOs belonging to different production sectors (dairy, fish, meat, and fresh-cut vegetable. Six of the forty-eight FBOs had samples positive for L. ivanovii on at least one sampling occasion. L. ivanovii was present in fifteen samples (fourteen environmental samples and one food sample. All but one of those positive samples derived from the dairy sector, where L. ivanovii prevalence was 1.7%. Six distinguishable pulsotypes were obtained by PFGE analysis, with one pulsotype being persistent in the environment of a dairy food business. Sequence analysis of the sigB gene showed that fourteen isolates belonged to L. ivanovii subsp. londoniensis, while only one isolate was L. ivanovii subsp. ivanovii. Cell invasion assays demonstrated that the majority of L. ivanovii strains were comparable to L. monocytogenes EGDe in their ability to invade CACO-2 epithelial cells whilst four isolates had significantly higher invasion efficiencies.

  1. Evaluation of an autoclave resistant anatomic nose model for the testing of nasal swabs.

    Science.gov (United States)

    Bartolitius, Lennart; Frickmann, Hagen; Warnke, Philipp; Ottl, Peter; Podbielski, Andreas

    2014-09-01

    A nose model that allows for the comparison of different modes of sample acquisition as well as of nasal swab systems concerning their suitability to detect defined quantities of intranasal microorganisms, and further for training procedures of medical staff, was evaluated. Based on an imprint of a human nose, a model made of a silicone elastomer was formed. Autoclave stability was assessed. Using an inoculation suspension containing Staphylococcus aureus and Staphylococcus epidermidis, the model was compared with standardized glass plate inoculations. Effects of inoculation time, mode of sampling, and sample storage time were assessed. The model was stable to 20 autoclaving cycles. There were no differences regarding the optimum coverage from the nose and from glass plates. Optimum sampling time was 1 h after inoculation. Storage time after sampling was of minor relevance for the recovery. Rotating the swab around its own axis while circling the nasal cavity resulted in best sampling results. The suitability of the assessed nose model for the comparison of sampling strategies and systems was confirmed. Without disadvantages in comparison with sampling from standardized glass plates, the model allows for the assessment of a correct sampling technique due to its anatomically correct shape.

  2. Investigation of internal radionuclide contamination from the analysis of nasal swabs and facial swipes

    International Nuclear Information System (INIS)

    Raymond Ko; Baki Sadi; Chunsheng Li; Chad Shew; Sharman Perera; Ed Waller; Kristine Mattson; Kathy Nielsen; David Kelly

    2014-01-01

    Nasal swabs and facial swipes have been used to screen potential internal radioactive contamination for decades. However, the ratio between the lung intake and the activity on a swab or a swipe varies according to the nature of the contaminant involved and the exposure conditions such as particle sizes of the contaminant and the humidity in the air. This paper reports the experimental results using stable La 2 O 3 as an analog for actinide oxides, focusing on the most important parameters such as humidity, plume velocity, and facial condition at a fixed room temperature of 23 ± 2 deg C. The results showed that the effects of humidity, plume velocity, and facial condition vary more on orofacial swipe/lung deposition ratios compared to nasal swab/lung deposition ratios. The amounts on nasal swabs tended to show smaller change with respect to parameters such as plume velocity, humidity, and skin moisture. The amounts on orofacial swipes varied by a factor of 10-15 among the samples collected across all parameters. Such variability would be expected to be even greater in a real-world scenario with a larger range of physiological and environmental conditions. (author)

  3. Seeking responsibility for the lost swab? Search elsewhere.

    Science.gov (United States)

    Wheeler, R; Blackburn, S; Biggs, H

    2014-04-01

    This article explores the possibility that the surgeon's control over his or her environment is not complete and that, in certain circumstances, the final swab count can be distinguished from the 'normal course of events'. We readily accept that most swabs and instruments are left inside patients simply as a result of substandard care but we cannot accept that this is invariably the case, and lessons from the common law are cited to illustrate the reasons why. We hope to persuade defendant lawyers that it might be worthwhile to tease out from surgeons under scrutiny how these factors may have influenced their practice on the day that a swab was retained.

  4. Swabs to genomes: a comprehensive workflow

    Directory of Open Access Journals (Sweden)

    Madison I. Dunitz

    2015-05-01

    Full Text Available The sequencing, assembly, and basic analysis of microbial genomes, once a painstaking and expensive undertaking, has become much easier for research labs with access to standard molecular biology and computational tools. However, there are a confusing variety of options available for DNA library preparation and sequencing, and inexperience with bioinformatics can pose a significant barrier to entry for many who may be interested in microbial genomics. The objective of the present study was to design, test, troubleshoot, and publish a simple, comprehensive workflow from the collection of an environmental sample (a swab to a published microbial genome; empowering even a lab or classroom with limited resources and bioinformatics experience to perform it.

  5. Validation of a same-day real-time PCR method for screening of meat and carcass swabs for Salmonella

    Science.gov (United States)

    2009-01-01

    Background One of the major sources of human Salmonella infections is meat. Therefore, efficient and rapid monitoring of Salmonella in the meat production chain is necessary. Validation of alternative methods is needed to prove that the performance is equal to established methods. Very few of the published PCR methods for Salmonella have been validated in collaborative studies. This study describes a validation including comparative and collaborative trials, based on the recommendations from the Nordic organization for validation of alternative microbiological methods (NordVal) of a same-day, non-commercial real-time PCR method for detection of Salmonella in meat and carcass swabs. Results The comparative trial was performed against a reference method (NMKL-71:5, 1999) using artificially and naturally contaminated samples (60 minced veal and pork meat samples, 60 poultry neck-skins, and 120 pig carcass swabs). The relative accuracy was 99%, relative detection level 100%, relative sensitivity 103% and relative specificity 100%. The collaborative trial included six laboratories testing minced meat, poultry neck-skins, and carcass swabs as un-inoculated samples and samples artificially contaminated with 1–10 CFU/25 g, and 10–100 CFU/25 g. Valid results were obtained from five of the laboratories and used for the statistical analysis. Apart from one of the non-inoculated samples being false positive with PCR for one of the laboratories, no false positive or false negative results were reported. Partly based on results obtained in this study, the method has obtained NordVal approval for analysis of Salmonella in meat and carcass swabs. The PCR method was transferred to a production laboratory and the performance was compared with the BAX Salmonella test on 39 pork samples artificially contaminated with Salmonella. There was no significant difference in the results obtained by the two methods. Conclusion The real-time PCR method for detection of Salmonella in meat

  6. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, J. R. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Piepel, G. F. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Amidan, B. G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Hess, B. M. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Sydor, M. A. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Deatherage Kaiser, B. L. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2018-03-13

    Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.

  7. Self-Collected Nasal Swabs for Respiratory Virus Surveillance

    Science.gov (United States)

    Jackson, Michael L.; Nguyen, Matthew; Kirlin, Beth; Madziwa, Lawrence

    2015-01-01

    We tested whether 135 patients reporting acute respiratory illness (ARI) could self-collect nasal swab specimens and ship them for laboratory testing. Most subjects (78.2%) collected and shipped their specimens without errors; 10.5% excluded ≥1 packing components; 12.9% made ≥1 packing errors. Self-swabbing at home is feasible for confirming ARI etiology. PMID:26613095

  8. Identification of rhabdoviral sequences in oropharyngeal swabs from German and Danish bats.

    Science.gov (United States)

    Fischer, Melina; Freuling, Conrad M; Müller, Thomas; Schatz, Juliane; Rasmussen, Thomas Bruun; Chriel, Mariann; Balkema-Buschmann, Anne; Beer, Martin; Hoffmann, Bernd

    2014-11-25

    In the frame of active lyssavirus surveillance in bats, oropharyngeal swabs from German (N = 2297) and Danish (N = 134) insectivorous bats were investigated using a newly developed generic pan-lyssavirus real-time reverse transcriptase PCR (RT-qPCR). In total, 15 RT-qPCR positive swabs were detected. Remarkably, sequencing of positive samples did not confirm the presence of bat associated lyssaviruses but revealed nine distinct novel rhabdovirus-related sequences. Several novel rhabdovirus-related sequences were detected both in German and Danish insectivorous bats. The results also prove that the novel generic pan-lyssavirus RT-qPCR offers a very broad detection range that allows the collection of further valuable data concerning the broad and complex diversity within the family Rhabdoviridae.

  9. Evaluation of the hygiene of ready-to-eat food preparation areas and practices in mobile food vendors in the UK.

    Science.gov (United States)

    Little, Christine; Sagoo, Satnam

    2009-12-01

    This study was undertaken to assess the cleanliness of food preparation areas, cleaning methods used, and the microbiological quality of water used by 1258 mobile food vendors in the UK. Samples collected included potable water (1102), cleaning cloths (801) and environmental swabs from food preparation surfaces (2704). Cleaning cloths were more heavily contaminated with Aerobic Colony Counts, Enterobacteriaceae, Escherichia coli, and Staphylococcus aureus compared to surfaces sampled. Surfaces that were visually dirty, wet, and chopping boards that were plastic or damaged also had high levels of these bacteria. Fifty-four percent of potable water samples were of poor microbiological quality; i.e. contained coliforms, E. coli and/or enterococci. A documented food safety management system was only evident in 40.1% of vendors and cleaning schedules were only used by 43.6%. Deficiencies in the correct use of cleaning materials, such as dilution factors and the minimum contact time for disinfectants, were identified.

  10. Statistical aspects of food safety sampling

    NARCIS (Netherlands)

    Jongenburger, I.; Besten, den H.M.W.; Zwietering, M.H.

    2015-01-01

    In food safety management, sampling is an important tool for verifying control. Sampling by nature is a stochastic process. However, uncertainty regarding results is made even greater by the uneven distribution of microorganisms in a batch of food. This article reviews statistical aspects of

  11. Detecting Rickettsia parkeri Infection from Eschar Swab Specimens

    Science.gov (United States)

    2013-05-01

    Detecting Rickettsia parkeri Infection from Eschar Swab Specimens Todd Myers, Tahaniyat Lalani, Mike Dent, Ju Jiang, Patrick L. Daly, Jason D...Maguire, and Allen L. Richards The typical clinical presentation of several spotted fever group Rickettsia infections includes eschars. Clinical...diagnosis by using an eschar swab specimen from patients infected with Rickettsia parkeri. Until 2004, all confirmed cases of tick-borne spotted

  12. Does Fine Needle Aspiration Microbiology Offer Any Benefit Over Wound Swab in Detecting the Causative Organisms in Surgical Site Infections?

    Science.gov (United States)

    Sudharsanan, Sundaramurthi; Gs, Sreenath; Sureshkumar, Sathasivam; Vijayakumar, Chellappa; Sujatha, Sistla; Kate, Vikram

    2017-09-01

    The objective of this study is to determine the role of ne needle aspiration microbiology (FNAM) in detecting the causative organisms of postoperative surgical site infections (SSIs) in comparison with the standard technique of surface swabbing. Ma- terials and Methods. In this study, 150 patients with SSIs following elective and emergency operations were included. In all patients, FNAM was performed along with conventional surface swabbing to identify the causative microorganism. Sensitivity of surface swab and FNAM was calculated as the number of samples collected from the diagnosed case of SSI. A total of 115 positive cultures were obtained from the 150 patients with SSIs; surface swab was positive in 110 cases and FNAM was positive in 94 cases. The mean number of organisms isolated by surface swab, and FNAM was 0.95 and 0.8, respectively. The sensitivity of surface swab was 94.3% in elective cases and 96.25% in emergency cases. The sensitivity of FNAM was 82.8% in elective cases and 82.5% in emergency cases. The sensitivity and negative predictive value of FNAM and surface swab did not signi cantly differ in clean elective cases. The overall sensitivity of surface swab and FNAM was 95.65% and 81.7%, respectively. Comparing the antibiotic suscep- tibility pattern, no difference was observed when the same organ- ism was isolated by both methods, indicating that FNAM does not offer bene t over the conventional wound surface swab in detecting microorganisms in SSI in both elective and emergency surgeries. In certain cases with unexplained wound infections, FNAM can be used as an investigation to identify speci c pathogens not detected by conventional surface swab.

  13. Detection of Campylobacter jejuni in rectal swab samples from Rousettus amplexicaudatus in the Philippines.

    Science.gov (United States)

    Hatta, Yuki; Omatsu, Tsutomu; Tsuchiaka, Shinobu; Katayama, Yukie; Taniguchi, Satoshi; Masangkay, Joseph S; Puentespina, Roberto; Eres, Eduardo; Cosico, Edison; Une, Yumi; Yoshikawa, Yasuhiro; Maeda, Ken; Kyuwa, Shigeru; Mizutani, Tetsuya

    2016-09-01

    Bats are the second diversity species of mammals and widely distributed in the world. They are thought to be reservoir and vectors of zoonotic pathogens. However, there is scarce report of the evidence of pathogenic bacteria kept in bats. The precise knowledge of the pathogenic bacteria in bat microbiota is important for zoonosis control. Thus, metagenomic analysis targeting the V3-V4 region of the 16S rRNA of the rectal microbiota in Rousettus amplexicaudatus was performed using high throughput sequencing. The results revealed that 103 genera of bacteria including Camplyobacter were detected. Campylobacter was second predominant genus, and Campylobacter coli and Campylobacter jejuni were identified in microbiome of R. amplexicaudatus. Campylobacteriosis is one of the serious bacterial diarrhea in human, and the most often implicated species as the causative agent of campylobacteriosis is C. jejuni. Therefore, we investigated the prevalence of C. jejuni in 91 wild bats with PCR. As a result of PCR assay targeted on 16S-23S intergenic spacer, partial genome of C. jejuni was detected only in five R. amplexicaudatus. This is the first report that C. jejuni was detected in bat rectal swab samples. C. jejuni is the most common cause of campylobacteriosis in humans, transmitted through water and contact with livestock animals. This result indicated that R. amplexicaudatus may be a carrier of C. jejuni.

  14. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    Science.gov (United States)

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...

  15. Improving communication at handover and transfer reduces retained swabs in maternity services.

    Science.gov (United States)

    Lean, Katie; Page, Bethan F; Vincent, Charles

    2018-01-01

    To reduce the incidence of retained vaginal swabs and near misses. A review of previous retained swab incidents and near misses in a large maternity unit identified handovers and transfers as a key point of vulnerability. Interventions were introduced to improve communication at handover from the delivery suite to theatre and from theatre to the high dependency unit. Process data was collected to monitor compliance. The outcome measures were the incidence of retained swab never events and the incidence of near misses. Chi-squared analysis was used to test the significance of the results. For transfers from delivery suite to theatre, verbal handover significantly increased from 28.8% to 75.6% (ptransfers to theatre post-intervention: in 88 (30.2%) of these transfers a vaginal swab was already in situ. In 70/88 (79.5%) of cases the presence of the swab was communicated to theatre staff in three ways (verbally, written and transfer of opened swab packets) according to the new policy. In the post-intervention period there were 56 women transferred from theatre to the high-dependency unit with a vaginal pack in situ: 52 (92.9%) of these women had a sticker in place serving as a constant reminder of the presence of the vaginal pack to staff. Following a baseline of four near misses in two months, there has been only one near miss in the 15 months since the interventions were implemented, (33.3% vs. 1.1%, pcommunication at handover and transfer can reduce the incidence of retained vaginal swabs and near misses. Further work is needed to raise the profile of swab counting in maternity settings: swab counting needs to be the responsibility of all disciplines, not just the responsibility of theatre staff. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Peyronie's disease after urethral swab, an unusual complication: a case report

    Directory of Open Access Journals (Sweden)

    Paulis G

    2015-11-01

    Full Text Available Gianni Paulis,1,2 Davide Barletta3 1Andrology Center, Regina Apostolorum Hospital, Albano Laziale, Rome, Italy; 2Castelfidardo Medical Team, Peyronie's Disease Care Center, Rome, Italy; 3Department of Urology, Andrology Center, San Matteo Hospital, Pavia, Italy Abstract: Urethral swabs are still currently used as a diagnostic tool when urethritis or prostatitis are suspected. Urologists are certainly aware that Peyronie's disease may occur after traumatic urethral instrumentation (catheterization, urethrocystoscopy, etc, but onset of Peyronie's disease after urethral swab for diagnostic purposes has never been reported in the literature. This paper presents the case of a patient who developed Peyronie's disease after a clumsy urethral swab insertion. It is an unusual, and to date unreported, complication which we would like to call attention to. In the case of our patient, the swab had been inserted to a greater depth than normally required and strong pressure had also been applied. During the procedure, the patient experienced severe urethral and penile pain, which was followed by urethrorrhagia, and later penile curvature. The patient was treated conservatively with good results, partly because the disease was still in its active stage and not yet stable. In the light of what we report, when ordering a urethral swab, physicians should always recommend that it be performed at testing centers that follow accurate, rigorous standards. Patients should also be informed that the test they are to undergo consists of a swab being inserted into the urethra for a short distance, not more than 2–3 cm. Keywords: genitourinary trauma, penile curvature, Peyronie, urethral swab

  17. Neutron activation analysis for antimetabolites. [in food samples

    Science.gov (United States)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  18. Comparison of four sampling methods for the detection of Salmonella in broiler litter.

    Science.gov (United States)

    Buhr, R J; Richardson, L J; Cason, J A; Cox, N A; Fairchild, B D

    2007-01-01

    Experiments were conducted to compare litter sampling methods for the detection of Salmonella. In experiment 1, chicks were challenged orally with a suspension of naladixic acid-resistant Salmonella and wing banded, and additional nonchallenged chicks were placed into each of 2 challenge pens. Nonchallenged chicks were placed into each nonchallenge pen located adjacent to the challenge pens. At 7, 8, 10, and 11 wk of age the litter was sampled using 4 methods: fecal droppings, litter grab, drag swab, and sock. For the challenge pens, Salmonella-positive samples were detected in 3 of 16 fecal samples, 6 of 16 litter grab samples, 7 of 16 drag swabs samples, and 7 of 16 sock samples. Samples from the nonchallenge pens were Salmonella positive in 2 of 16 litter grab samples, 9 of 16 drag swab samples, and 9 of 16 sock samples. In experiment 2, chicks were challenged with Salmonella, and the litter in the challenge and adjacent nonchallenge pens were sampled at 4, 6, and 8 wk of age with broilers remaining in all pens. For the challenge pens, Salmonella was detected in 10 of 36 fecal samples, 20 of 36 litter grab samples, 14 of 36 drag swab samples, and 26 of 36 sock samples. Samples from the adjacent nonchallenge pens were positive for Salmonella in 6 of 36 fecal droppings samples, 4 of 36 litter grab samples, 7 of 36 drag swab samples, and 19 of 36 sock samples. Sock samples had the highest rates of Salmonella detection. In experiment 3, the litter from a Salmonella-challenged flock was sampled at 7, 8, and 9 wk by socks and drag swabs. In addition, comparisons with drag swabs that were stepped on during sampling were made. Both socks (24 of 36, 67%) and drag swabs that were stepped on (25 of 36, 69%) showed significantly more Salmonella-positive samples than the traditional drag swab method (16 of 36, 44%). Drag swabs that were stepped on had comparable Salmonella detection level to that for socks. Litter sampling methods that incorporate stepping on the sample

  19. Optimized methods for total nucleic acid extraction and quantification of the bat white-nose syndrome fungus, Pseudogymnoascus destructans, from swab and environmental samples.

    Science.gov (United States)

    Verant, Michelle L; Bohuski, Elizabeth A; Lorch, Jeffery M; Blehert, David S

    2016-03-01

    The continued spread of white-nose syndrome and its impacts on hibernating bat populations across North America has prompted nationwide surveillance efforts and the need for high-throughput, noninvasive diagnostic tools. Quantitative real-time polymerase chain reaction (qPCR) analysis has been increasingly used for detection of the causative fungus, Pseudogymnoascus destructans, in both bat- and environment-associated samples and provides a tool for quantification of fungal DNA useful for research and monitoring purposes. However, precise quantification of nucleic acid from P. destructans is dependent on effective and standardized methods for extracting nucleic acid from various relevant sample types. We describe optimized methodologies for extracting fungal nucleic acids from sediment, guano, and swab-based samples using commercial kits together with a combination of chemical, enzymatic, and mechanical modifications. Additionally, we define modifications to a previously published intergenic spacer-based qPCR test for P. destructans to refine quantification capabilities of this assay. © 2016 The Author(s).

  20. Optimized methods for total nucleic acid extraction and quantification of the bat white-nose syndrome fungus, Pseudogymnoascus destructans, from swab and environmental samples

    Science.gov (United States)

    Verant, Michelle; Bohuski, Elizabeth A.; Lorch, Jeffrey M.; Blehert, David

    2016-01-01

    The continued spread of white-nose syndrome and its impacts on hibernating bat populations across North America has prompted nationwide surveillance efforts and the need for high-throughput, noninvasive diagnostic tools. Quantitative real-time polymerase chain reaction (qPCR) analysis has been increasingly used for detection of the causative fungus, Pseudogymnoascus destructans, in both bat- and environment-associated samples and provides a tool for quantification of fungal DNA useful for research and monitoring purposes. However, precise quantification of nucleic acid fromP. destructans is dependent on effective and standardized methods for extracting nucleic acid from various relevant sample types. We describe optimized methodologies for extracting fungal nucleic acids from sediment, guano, and swab-based samples using commercial kits together with a combination of chemical, enzymatic, and mechanical modifications. Additionally, we define modifications to a previously published intergenic spacer–based qPCR test for P. destructans to refine quantification capabilities of this assay.

  1. Equivalence of self- and staff-collected nasal swabs for the detection of viral respiratory pathogens.

    Directory of Open Access Journals (Sweden)

    Manas K Akmatov

    Full Text Available BACKGROUND: The need for the timely collection of diagnostic biosamples during symptomatic episodes represents a major obstacle to large-scale studies on acute respiratory infection (ARI epidemiology. This may be circumvented by having the participants collect their own nasal swabs. We compared self- and staff-collected swabs in terms of swabbing quality and detection of viral respiratory pathogens. METHODOLOGY/PRINCIPAL FINDINGS: We conducted a prospective study among employees of our institution during the ARI season 2010/2011 (December-March. Weekly emails were sent to the participants (n = 84, reminding them to come to the study center in case of new symptoms. The participants self-collected an anterior nasal swab from one nostril, and trained study personnel collected one from the other nostril. The participants self-collected another two swabs (one from each nostril on a subsequent day. Human β-actin DNA concentration was determined in the swabs as a quality control. Viral respiratory pathogens were detected by multiplex RT-PCR (Seeplex RV15 kit, Seegene, Eschborn, Germany. Of 84 participants, 56 (67% reported at least one ARI episode, 18 participants two, and one participant three. Self-swabbing was highly accepted by the participants. The amount of β-actin DNA per swab was higher in the self- than in the staff-collected swabs (p = 0.008. β-actin concentration was lower in the self-swabs collected on day 1 than in those collected on a subsequent day (p<0.0001. A respiratory viral pathogen was detected in 31% (23/75 of staff- and in 35% (26/75 of self-collected swabs (p = 0.36. With both approaches, the most frequently identified pathogens were human rhinoviruses A/B/C (12/75 swabs, 16% and human coronavirus OC43 (4/75 swabs, 5%. There was almost perfect agreement between self- and staff-collected swabs in terms of pathogen detection (agreement = 93%, kappa = 0.85, p<0.0001. CONCLUSIONS/SIGNIFICANCE: Nasal self-swabbing

  2. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.

    Science.gov (United States)

    Nenadić, Dane; Pavlović, Miloš D

    2015-06-01

    Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.

  3. Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food

    International Nuclear Information System (INIS)

    Lari, L; Dudkiewicz, A

    2014-01-01

    Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility

  4. Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food

    Science.gov (United States)

    Lari, L.; Dudkiewicz, A.

    2014-06-01

    Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility.

  5. Molecular analysis of partial VP-2 gene amplified from rectal swab samples of diarrheic dogs in Pakistan confirms the circulation of canine parvovirus genetic variant CPV-2a and detects sequences of feline panleukopenia virus (FPV).

    Science.gov (United States)

    Ahmed, Nisar; Riaz, Adeel; Zubair, Zahra; Saqib, Muhammad; Ijaz, Sehrish; Nawaz-Ul-Rehman, Muhammad Shah; Al-Qahtani, Ahmed; Mubin, Muhammad

    2018-03-15

    The infection in dogs due to canine parvovirus (CPV), is a highly contagious one with high mortality rate. The present study was undertaken for a detailed genetic analysis of partial VP2 gene i.e., 630 bp isolated from rectal swab samples of infected domestic and stray dogs from all areas of district Faisalabad. Monitoring of viruses is important, as continuous prevalence of viral infection might be associated with emergence of new virulent strains. In the present study, 40 rectal swab samples were collected from diarrheic dogs from different areas of district Faisalabad, Pakistan, in 2014-15 and screened for the presence of CPV by immunochromatography. Most of these dogs were stray dogs showing symptoms of diarrhea. Viral DNA was isolated and partial VP2 gene was amplified using gene specific primer pair Hfor/Hrev through PCR. Amplified fragments were cloned in pTZ57R/T (Fermentas) and completely sequenced. Sequences were analyzed and assembled by the Lasergene DNA analysis package (v8; DNAStar Inc., Madison, WI, USA). The results with immunochromatography showed that 33/40 (82%) of dogs were positive for CPV. We were able to amplify a fragment of 630 bp from 25 samples. In 25 samples the sequences of CPV-2a were detected showing the amino acid substitution Ser297Ala and presence of amino acid (426-Asn) in partial VP2 protein. Interestingly the BLAST analysis showed the of feline panleukopenia virus (FPV) sequences in 3 samples which were already positive for new CPV-2a, with 99% sequence homology to other FPV sequences present in GenBank. Phylogenetic analysis showed clustering of partial CPV-VP-2 gene with viruses from China, India, Japan and Uruguay identifying a new variant, whereas the 3 FPV sequences showed immediate ancestral relationship with viruses from Portugal, South Africa and USA. Interesting observation was that CPV are clustering away from the commercial vaccine strains. In this work we provide a better understanding of CPV prevailing in Pakistan

  6. Complete Genome Sequence of a Porcine Polyomavirus from Nasal Swabs of Pigs with Respiratory Disease.

    Science.gov (United States)

    Hause, Ben M; Smith, Catherine; Bishop, Brian; Stewart, Chelsea; Simonson, Randy

    2018-04-26

    Metagenomic sequencing of pooled nasal swabs from pigs with unexplained respiratory disease identified a large number of reads mapping to a previously uncharacterized porcine polyomavirus. Sus scrofa polyomavirus 2 was most closely related to betapolyomaviruses frequently detected in mammalian respiratory samples. Copyright © 2018 Hause et al.

  7. Comparison between nasopharyngeal swab and nasal wash, using culture and PCR, in the detection of potential respiratory pathogens.

    Science.gov (United States)

    Gritzfeld, Jenna F; Roberts, Paul; Roche, Lorna; El Batrawy, Sherouk; Gordon, Stephen B

    2011-04-13

    Nasopharyngeal carriage of potential pathogens is important as it is both the major source of transmission and the prerequisite of invasive disease. New methods for detecting carriage could improve comfort, accuracy and laboratory utility. The aims of this study were to compare the sensitivities of a nasopharyngeal swab (NPS) and a nasal wash (NW) in detecting potential respiratory pathogens in healthy adults using microbiological culture and PCR. Healthy volunteers attended for nasal washing and brushing of the posterior nasopharynx. Conventional and real-time PCR were used to detect pneumococcus and meningococcus. Statistical differences between the two nasal sampling methods were determined using a nonparametric Mann-Whitney U test; differences between culture and PCR methods were determined using the McNemar test.Nasal washing was more comfortable for volunteers than swabbing (n = 24). In detection by culture, the NW was significantly more likely to detect pathogens than the NPS (p < 0.00001). Overall, there was a low carriage rate of pathogens in this sample; no significant difference was seen in the detection of bacteria between culture and PCR methods. Nasal washing and PCR may provide effective alternatives to nasopharyngeal swabbing and classical microbiology, respectively.

  8. Effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats.

    Science.gov (United States)

    Mair, A; Martinez-Taboada, F; Nitzan, M

    2017-01-14

    This study aimed to evaluate the effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats. Following anaesthetic induction, the following pulse oximeter probe configurations were performed: no gauze swab (control), placement of a gauze swab between the tongue and the probe, placement of different thicknesses of gauze swab, placement of red cotton fabric, placement of a sheet of white paper and placement of the probe and gauze swab on different locations on the tongue. Oxygen saturation (SpO 2 ) and peripheral perfusion index (PI) were recorded. Placement of a gauze swab between the pulse oximeter probe and the tongue in anaesthetised dogs and cats resulted in significantly higher SpO 2 values compared with the control group. In dogs, PI values were significantly higher than the control in all groups except the quarter thickness swab group. In cats, PI was significantly higher in the double thickness swab and white paper groups compared with the control. Cats had significantly higher SpO 2 and lower PI values than dogs. The authors propose that increased contact pressure is responsible for significantly higher SpO 2 and PI readings with the use of a lingual gauze swab resulting from changes in transmural pressure and arterial compliance. British Veterinary Association.

  9. Buccal swab, a minimally invasive method for the screening of oral cancer in active smokers

    Science.gov (United States)

    Suyatmi; Subiyantoro, P.; Indrakila, S.

    2018-05-01

    Smoking is the main risk factor for developing oral cancer. The previous study showed that there was a strong correlation between the length of smoking with the risk to develop oral cancer. Early detection of epithelial changes of oral mucosa will be a good prevention of the incidence of oral cancer among active smokers. This study evaluated the potential use of buccal swab for the screening of early signs of malignancy in active smokers. This study involved 80 participants including those who were smokers and non smokers. The buccal swab was conducted using sterile cytobrush. An epithelial smear was made from the buccal swab and stained with Papanicolaou’s technique. An cytomorphometric analysis was conducted by comparing the ratio of nuclear cell to cytoplasmic diameter (ND/CD) between the two groups. The mean of ND observed in this study were 8.963µ for active smokers and 7.991µ for non smokers groups. While the mean of CD were 58.249µ and 63.473µ for active smoker and non-smoker respectively. The mean of ND/CD ratio were 0.156 for active smokers and 0.129 for non smokers groups. This study detected a significant difference on the ND/CD ratio among active smokers vs non smokers (p<0.0001 95% CI = -0.040 – -0.014). In conclusion buccal swab could be a routine procedure to obtain sample for identification of changes in cells morphology to screen an early development of oral cancer.

  10. Listeria monocytogenes Identification in Food of Animal Origin Used with Real Time PCR

    Directory of Open Access Journals (Sweden)

    Jaroslav Pochop

    2013-10-01

    Full Text Available The aim of this study was to follow the contamination of food with Listeria monocytogenes by using Step One real time polymerase chain reaction (RT PCR. We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and SensiFAST SYBR Hi-ROX Kit for the real-time PCR performance. In 20 samples of food of animal origin with incubation were detected strains of Listeria monocytogenes in 9 samples (swabs. Eleven samples were negative. Our results indicated that the real-time PCR assay developed in this study could sensitively detect Listeria monocytogenes in food of animal origin without incubation. This could prevent infection caused by Listeria monocytogenes, and also could benefit food manufacturing companies by extending their product’s shelf-life as well as saving the cost of warehousing their food products while awaiting pathogen testing results. The rapid real-time PCR-based method performed very well compared to the conventional method. It is a fast, simple, specific and sensitive way to detect nucleic acids, which could be used in clinical diagnostic tests in the future.

  11. Human leukocyte antigen typing using buccal swabs as accurate and non-invasive substitute for venipuncture in children at risk for celiac disease.

    Science.gov (United States)

    Adriaanse, Marlou P M; Vreugdenhil, Anita C E; Vastmans, Véronique; Groeneveld, Lisette; Molenbroeck, Stefan; Schott, Dina A; Voorter, Christina E M; Tilanus, Marcel G J

    2016-10-01

    Human leukocyte antigen (HLA) typing is an important step in the diagnostic algorithm for celiac disease (CD) and is also used for screening purposes. Collection of blood is invasive and accompanied with emotional impact especially in children. Genetic technological progress now enables HLA typing from buccal cell samples. This study evaluated the reliability and feasibility of HLA typing for CD-associated HLA polymorphisms using buccal swabs as routine test in high-risk individuals. Blood and buccal swabs of 77 children and adolescents with high risk for CD were prospectively collected in this cohort study. Buccal swab collection was performed either by the investigator at the outpatient clinic or by the patient or its parents at home. To evaluate the possibility of self-administration, three families performed the test at home. DNA was extracted using an adapted QIAamp method. Quantity, quality, and purity of DNA were recorded. HLA-DRB1, HLA-DQA1, and HLA-DQB1 typing was examined on buccal cell-derived and blood-derived DNA at low and, if necessary, high resolution level, using sequence-specific oligonucleotide and sequence-based typing, respectively. DNA isolation using buccal swabs yielded a good quality and sufficient quantity of DNA to perform HLA-DQ typing in all individuals. HLA typing results on buccal cell-derived DNA were identical to typing on blood-derived DNA, also for the self-administered samples. Introduction of the buccal swab test for HLA typing of CD risk in routine diagnostics can omit the current venipuncture and enables self-administration at home. Therefore, the buccal swab test is beneficial for individuals with a clinical suspicion for CD, as well as for screening purposes in high-risk populations. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  12. Food variety, dietary diversity, and food characteristics among convenience samples of Guatemalan women.

    Science.gov (United States)

    Soto-Méndez, María José; Campos, Raquel; Hernández, Liza; Orozco, Mónica; Vossenaar, Marieke; Solomons, Noel W

    2011-01-01

    To compare variety and diversity patterns and dietary characteristics in Guatemalan women. Two non-consecutive 24-h recalls were conducted in convenience samples of 20 rural Mayan women and 20 urban students. Diversity scores were computed using three food-group systems.Variety and diversity scores and dietary origin and characteristics were compared between settings using independent t-test or Mann-Whitney-U-test. Dietary variety and diversity were generally greater in the urban sample when compared to the rural sample, depending on the number of days and food-group system used for evaluation.The diet was predominantly plant-based and composed of non-fortified food items in both areas.The rural diet was predominantly composed of traditional,non-processed foods. The urban diet was mostly based on non-traditional and processed items. Considerations of intervention strategies for dietary improvement and health protection for the Guatemalan countryside should still rely on promotion and preservation of traditional food selection.

  13. Product samples stimulate choice of unfamiliar healthful food products.

    Science.gov (United States)

    Schickenberg, B; van Assema, P; Brug, J; de Vries, N K

    2011-08-01

    The purpose of this study was to assess whether the availability of a product sample of an unfamiliar low-fat or fruit and vegetable products stimulates choice for this product among food neophobic young adults. The study had a 2 (experimental vs. control group) by 4 (low-fat bread spread, low-fat cheese, fruit juice, fruit and vegetable juice) between subjects design with a pre-and post-experiment questionnaire. The study was conducted in restaurant rooms of several educational institutions in the Netherlands among a convenience sample of 197 food neophobic young adults aged 17-25 years. A small bite or sip-sized sample of the target product was provided as an intervention. The effect measure was choice of either an unfamiliar healthful food product or a traditional food product. Offering a sample of an unfamiliar healthful food product resulted in 51% of the participants in the experimental group choosing this product vs. 36.4% in the control group. Providing food product samples seems to be a promising strategy in healthy diet promotion programs for food neophobic young adults to increase first-time trial of unfamiliar low-fat and fruit and vegetable products. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Detection of Listeria monocytogenes in ready-to-eat food by Step One real-time polymerase chain reaction.

    Science.gov (United States)

    Pochop, Jaroslav; Kačániová, Miroslava; Hleba, Lukáš; Lopasovský, L'ubomír; Bobková, Alica; Zeleňáková, Lucia; Stričík, Michal

    2012-01-01

    The aim of this study was to follow contamination of ready-to-eat food with Listeria monocytogenes by using the Step One real time polymerase chain reaction (PCR). We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and MicroSEQ® Listeria monocytogenes Detection Kit for the real-time PCR performance. In 30 samples of ready-to-eat milk and meat products without incubation we detected strains of Listeria monocytogenes in five samples (swabs). Internal positive control (IPC) was positive in all samples. Our results indicated that the real-time PCR assay developed in this study could sensitively detect Listeria monocytogenes in ready-to-eat food without incubation.

  15. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections

    Directory of Open Access Journals (Sweden)

    Nenadić Dane

    2015-01-01

    Full Text Available Bacground/Aim. Vaginal and cervical swab culture is still very common procedure in our country’s everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM, vaginal pH and potassium hydroxide (KOH test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. Methods. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. Results. In 36 (6% patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11% women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19% women had BV, 19 (4% vaginitis, and 72 (14% candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21% had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30% women - in 83 (54% of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Conclusion. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal

  16. Detection of Mycoplasma pneumoniae in simulated and true clinical throat swab specimens by nanorod array-surface-enhanced Raman spectroscopy.

    Directory of Open Access Journals (Sweden)

    Suzanne L Hennigan

    Full Text Available The prokaryote Mycoplasma pneumoniae is a major cause of respiratory disease in humans, accounting for 20% of all community-acquired pneumonia and the leading cause of pneumonia in older children and young adults. The limitations of existing options for mycoplasma diagnosis highlight a critical need for a new detection platform with high sensitivity, specificity, and expediency. Here we evaluated silver nanorod arrays (NA as a biosensing platform for detection and differentiation of M. pneumoniae in culture and in spiked and true clinical throat swab samples by surface-enhanced Raman spectroscopy (SERS. Three M. pneumoniae strains were reproducibly differentiated by NA-SERS with 95%-100% specificity and 94-100% sensitivity, and with a lower detection limit exceeding standard PCR. Analysis of throat swab samples spiked with M. pneumoniae yielded detection in a complex, clinically relevant background with >90% accuracy and high sensitivity. In addition, NA-SERS correctly classified with >97% accuracy, ten true clinical throat swab samples previously established by real-time PCR and culture to be positive or negative for M. pneumoniae. Our findings suggest that the unique biochemical specificity of Raman spectroscopy, combined with reproducible spectral enhancement by silver NA, holds great promise as a superior platform for rapid and sensitive detection and identification of M. pneumoniae, with potential for point-of-care application.

  17. PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology

    Science.gov (United States)

    Kellogg, Christina A.; Piceno, Yvette M.; Tom, Lauren M.; DeSantis, Todd Z.; Zawada, David G.; Andersen, Gary L.

    2012-01-01

    Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.

  18. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients.

    Science.gov (United States)

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy P; Pardee, Dana J; McLean, Sarah A; Panther, Lori A; Gelman, Marcy; Mimiaga, Matthew J; Potter, Jennifer E

    2018-01-01

    High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21-64 years. Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants

  19. Comparison of the diagnostic performance of bacterial culture of nasopharyngeal swab and bronchoalveolar lavage fluid samples obtained from calves with bovine respiratory disease.

    Science.gov (United States)

    Capik, Sarah F; White, Brad J; Lubbers, Brian V; Apley, Michael D; DeDonder, Keith D; Larson, Robert L; Harhay, Greg P; Chitko-McKown, Carol G; Harhay, Dayna M; Kalbfleisch, Ted S; Schuller, Gennie; Clawson, Michael L

    2017-03-01

    OBJECTIVE To compare predictive values, extent of agreement, and gamithromycin susceptibility between bacterial culture results of nasopharyngeal swab (NPS) and bronchoalveolar lavage fluid (BALF) samples obtained from calves with bovine respiratory disease (BRD). ANIMALS 28 beef calves with clinical BRD. PROCEDURES Pooled bilateral NPS samples and BALF samples were obtained for bacterial culture from calves immediately before and at various times during the 5 days after gamithromycin (6 mg/kg, SC, once) administration. For each culture-positive sample, up to 12 Mannheimia haemolytica, 6 Pasteurella multocida, and 6 Histophilus somni colonies underwent gamithromycin susceptibility testing. Whole-genome sequencing was performed on all M haemolytica isolates. For paired NPS and BALF samples collected 5 days after gamithromycin administration, the positive and negative predictive values for culture results of NPS samples relative to those of BALF samples and the extent of agreement between the sampling methods were determined. RESULTS Positive and negative predictive values of NPS samples were 67% and 100% for M haemolytica, 75% and 100% for P multocida, and 100% and 96% for H somni. Extent of agreement between results for NPS and BALF samples was substantial for M haemolytica (κ, 0.71) and H somni (κ, 0.78) and almost perfect for P multocida (κ, 0.81). Gamithromycin susceptibility varied within the same sample and between paired NPS and BALF samples. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated culture results of NPS and BALF samples from calves with BRD should be interpreted cautiously considering disease prevalence within the population, sample collection relative to antimicrobial administration, and limitations of diagnostic testing methods.

  20. Rapid detection of acetamiprid in foods using surface-enhanced Raman spectroscopy (SERS).

    Science.gov (United States)

    Wijaya, Wisiani; Pang, Shintaro; Labuza, Theodore P; He, Lili

    2014-04-01

    Acetamiprid is a neonicotinoid pesticide that is commonly used in modern farming. Acetamiprid residue in food commodities can be a potential harm to human and has been implicated in the honey bee hive die off crisis. In this study, we developed rapid, simple, and sensitive methods to detect acetamiprid in apple juice and on apple surfaces using surface-enhanced Raman spectroscopy (SERS). No pretreatment of apple juice sample was performed. A simple surface swab method was used to recover acetamiprid from the apple surface. Samples were incubated with silver dendrites for several minutes and SERS spectra were taken directly from the silver surface. Detection of a set of 5 apple juice samples can be done within 10 min. The swab-SERS method took 15 min for a set of 5 samples. Resulting spectral data were analyzed using principal component analysis. The highest acetamiprid peak at 634 cm(-1) was used to detect and quantify the amount of acetamiprid spiked in 1:1 water-methanol solvent, apple juice, and on apple surface. The SERS method was able to successfully detect acetamiprid at 0.5 μg/mL (0.5 ppm) in solvent, 3 μg/mL (3 ppm) in apple juice, and 0.125 μg/cm(2) on apple surfaces. The SERS methods provide simple, rapid, and sensitive ways to detect acetamiprid in beverages and on the surfaces of thick skinned fruits and vegetables. © 2014 Institute of Food Technologists®

  1. Influence of audiovisuals and food samples on consumer acceptance of food irradiation

    International Nuclear Information System (INIS)

    Pohlman, A.J.; Wood, O.B.; Mason, A.C.

    1994-01-01

    The effects of audiovisual presentation on consumers' knowledge and attitudes toward food irradiation were demonstrated. Food irradiation is a method of food preservation that can destroy the microorganisms responsible for many foodborne illnesses and food spoilage. However, the food industry has been slow to adopt this method because it is unsure of consumer acceptance. One hundred and seventy-nine consumers were given a slide-tape presentation on food irradiation. Test subjects were also presented with a sample of irradiated strawberries. It was found that participants knew more about and were more positive toward food irradiation following the educational program. These findings demonstrate the value of educational materials in influencing the food preferences of consumers

  2. Effective sampling strategy to detect food and feed contamination

    NARCIS (Netherlands)

    Bouzembrak, Yamine; Fels, van der Ine

    2018-01-01

    Sampling plans for food safety hazards are aimed to be used to determine whether a lot of food is contaminated (with microbiological or chemical hazards) or not. One of the components of sampling plans is the sampling strategy. The aim of this study was to compare the performance of three

  3. Notes on sample preparation of food: food of plant and animal origins, and daily meals

    International Nuclear Information System (INIS)

    Heilgeist, M.

    1992-01-01

    The procedure of food sample preparation to determine their specific radioactivity, analogous to chemical residue analysis, is laid down in the relevant sets of regulations. Several procedural steps of sample preparation of single food and composite food are dealt with. The sample size necessary for gamma spectroscopy and Sr-89/Sr-90 analysis, and the incineration step to enrich radionuclides are explained. Finally, enrichment by freeze drying of the high-volatile radionuclide I-131 is considered. (orig.) [de

  4. Food and feed safety assessment: the importance of proper sampling.

    Science.gov (United States)

    Kuiper, Harry A; Paoletti, Claudia

    2015-01-01

    The general principles for safety and nutritional evaluation of foods and feed and the potential health risks associated with hazardous compounds are described as developed by the Food and Agriculture Organization (FAO) and the World Health Organization (WHO) and further elaborated in the European Union-funded project Safe Foods. We underline the crucial role of sampling in foods/feed safety assessment. High quality sampling should always be applied to ensure the use of adequate and representative samples as test materials for hazard identification, toxicological and nutritional characterization of identified hazards, as well as for estimating quantitative and reliable exposure levels of foods/feed or related compounds of concern for humans and animals. The importance of representative sampling is emphasized through examples of risk analyses in different areas of foods/feed production. The Theory of Sampling (TOS) is recognized as the only framework within which to ensure accuracy and precision of all sampling steps involved in the field-to-fork continuum, which is crucial to monitor foods and feed safety. Therefore, TOS must be integrated in the well-established FAO/WHO risk assessment approach in order to guarantee a transparent and correct frame for the risk assessment and decision making process.

  5. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores.

    Science.gov (United States)

    Perry, K Allison; O'Connell, Heather A; Rose, Laura J; Noble-Wang, Judith A; Arduino, Matthew J

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis . Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T 0 ) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 10 2 , p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.

  6. Prevalence of mycoplasmas in the semen and vaginal swabs of Danish stallions and mares

    DEFF Research Database (Denmark)

    Baczynska, Agata; Fedder, J.; Schougaard, H.

    2006-01-01

    may occur. Mycoplasmas have been implicated in genital disorders and infertility of many species including humans and horses. However, their role as commensals or pathogens of the genital tract of horses is still not determined. Bacteriological examinations made on the fossa glandis, urethra, penis...... and semen of stallions, showed the presence of different Mycoplasma species. Therefore our study aimed to find the prevalence of Mycoplasma species and a possible association with fertility problems in Danish riding horses. Eighty semen samples from stallions and 19 vaginal swab samples from mares were...

  7. Prevalence of mycoplasmas in the semen and vaginal swabs of Danish stallions and mares

    DEFF Research Database (Denmark)

    Baczynska, Agata; Fedder, J; Schougaard, H

    2007-01-01

    may occur. Mycoplasmas have been implicated in genital disorders and infertility of many species including humans and horses. However, their role as commensals or pathogens of the genital tract of horses is still not determined. Bacteriological examinations made on the fossa glandis, urethra, penis...... and semen of stallions, showed the presence of different Mycoplasma species. Therefore our study aimed to find the prevalence of Mycoplasma species and a possible association with fertility problems in Danish riding horses. Eighty semen samples from stallions and 19 vaginal swab samples from mares were...

  8. Comparison of three methods for the recovery of skin pathogens from impetigo swabs collected in a remote community of Northern Territory, Australia.

    Science.gov (United States)

    Bowen, Asha C; Tong, Steven Y C; Chatfield, Mark D; Andrews, Ross M; Carapetis, Jonathan R

    2013-06-01

    Impetigo is a common infection in children living in remote areas. Immediate plating of impetigo swabs is the gold standard for bacterial recovery but is rarely feasible in remote regions. Bacterial culture increases our understanding of antibiotic resistance and strain diversity, which guides treatment protocols and epidemiological monitoring. We investigated three practical alternatives for recovering Streptococcus pyogenes and Staphylococcus aureus from transported swabs: dry swabs transported at 4°C with desiccant and plated within 48 h; swabs inoculated into skim milk tryptone glucose glycerol broth (STGGB), transported at 4°C, stored at -70°C and plated within 61 days; and ESwabs inoculated into Amies broth, transported at 4°C and plated within 48 h. Detection of Strep. pyogenes and Staph. aureus from simultaneously collected swabs was compared for the dry vs STGGB (36 sores) and the STGGB vs Amies (39 sores) methods. Swabs were collected from 43 children (75 sores sampled) in a remote community of Northern Territory, Australia in November 2011. The children had impetigo and were participating in the Skin Sore Trial [Australian Clinical Trials Registry ACTRN12609000858291]. Recovery of Strep. pyogenes for dry vs STGGB was 72% (26/36) and 92% (33/36) and for STGGB vs Amies was 92% (36/39) for both methods. Staphylococcus aureus recovery for dry vs STGGB was 69% (25/36) and 72% 26/36) and for STGGB vs Amies was 74% (29/39) and 85% (33/39). STGGB and Amies media provided higher recovery of Strep. pyogenes than dry swabs. These results and the opportunity to batch and store specimens for molecular studies support the use of STGGB transport media for future impetigo research.

  9. Surveillance of Salmonella enteritidis in layer houses: a retrospective comparison of the Food and Drug Administration's egg safety rule (2010-2011) and the California Egg Quality Assurance Program (2007-2011).

    Science.gov (United States)

    Pitesky, Maurice; Charlton, Bruce; Bland, Mark; Rolfe, Dan

    2013-03-01

    Between July 2007 and December 2011, 2660 environmental drag swab samples were collected in total from California layer flocks on behalf of the California Egg Quality Assurance Program (CEQAP), the egg safety rule (21 CFR Parts 16 and 118) of the Food and Drug Administration (FDA), or both. The samples were processed by the California Animal Health and Food Safety Lab, and positive or negative results for Salmonella enterica serovar Enteritidis (SE) were recorded. This study retrospectively compares the differences between the FDA and CEQAP programs with respect to their SE environmental sampling surveillance results. To accomplish this comparison, two different CEQAP (new and old) data sets representing different SE environmental surveillance approaches in the life of the flock were compared against each other and against the FDA's SE environmental testing plan. Significant differences were noted between the CEQAP and FDA programs with respect to the prevalence of SE in the farm environment. Analyses of the prevalence of SE at different stages in the flock's life cycle (chick papers, preproduction, midproduction, postmolt, and premarket) found the highest prevalence of SE in premarket (11.9%), followed by postmolt (3.5%) and midproduction (3.4%), and there was a tie between chick papers and preproduction (2.1%). To assess the main effects of the presence of SE in the farm environment, backwards binary logistic regression was used. Of six independent variables examined (age of flock, year, season, owner, CEQAP membership, and analysis of pooled samples vs. individual swabs), only age of flock, owner, and year were determined to be significant factors in the final model. Although CEQAP membership and pooling vs. individuals swabs were not included in the final model, Pearson chi-square tests did show significantly higher odds of SE for non-CEQAP member farms and higher odds of SE in pooled samples vs. individual swabs.

  10. A study of female genital swabs in primary health care centres in Jos, Nigeria

    Directory of Open Access Journals (Sweden)

    Samuel Nwadioha

    2011-03-01

    Full Text Available Objective: To detect some common microbial agents of female genital discharges in order to improve the current syndromic management of abnormal vaginal discharge. Methods: A prospective study of female genital swabs collected from Primary Health Care Centres, Jos, and analysed for microscopy, culture and sensitivity in Jos University Teaching Hospital, December 2006 to December 2007 was carried out. Results: Microbial agents were detected in 70% (700 of a total 1 000 female genital swabs studied. Candida species peaked with 42.0% (420 out of the 1000 samples, followed by Gardnerella vaginalis, an agent of bacterial vaginosis with 26.0%. The distribution of abnormal vaginal discharge was highest in young adults aged 21 to 30 years. Conclusions: It is concluded that abnormal vaginal discharge is most prevalent in the young sexually active age group with Candida species as the commonest agent. We recommend prevention, early diagnosis and prompt treatment of infective female genital discharge in order to reduce the menace of HIV transmission.

  11. Comparison between nasopharyngeal swab and nasal wash, using culture and PCR, in the detection of potential respiratory pathogens

    Directory of Open Access Journals (Sweden)

    El Batrawy Sherouk

    2011-04-01

    Full Text Available Abstract Background Nasopharyngeal carriage of potential pathogens is important as it is both the major source of transmission and the prerequisite of invasive disease. New methods for detecting carriage could improve comfort, accuracy and laboratory utility. The aims of this study were to compare the sensitivities of a nasopharyngeal swab (NPS and a nasal wash (NW in detecting potential respiratory pathogens in healthy adults using microbiological culture and PCR. Results Healthy volunteers attended for nasal washing and brushing of the posterior nasopharynx. Conventional and real-time PCR were used to detect pneumococcus and meningococcus. Statistical differences between the two nasal sampling methods were determined using a nonparametric Mann-Whitney U test; differences between culture and PCR methods were determined using the McNemar test. Nasal washing was more comfortable for volunteers than swabbing (n = 24. In detection by culture, the NW was significantly more likely to detect pathogens than the NPS (p Conclusions Nasal washing and PCR may provide effective alternatives to nasopharyngeal swabbing and classical microbiology, respectively.

  12. Use of the VS-sense swab in diagnosing vulvovaginitis.

    Science.gov (United States)

    Sobel, Jack D; Nyirjesy, Paul; Kessary, Hadar; Ferris, Daron G

    2009-09-01

    Although pH assessment of vaginal secretions is beneficial for diagnosing vaginitis, it is not commonly done. The purpose of this study was to determine the performance characteristics of the VS-Sense (pH test) swab (Common Sense, Ltd., Caesarea, Israel) in augmenting the diagnosis of vaginitis. We prospectively studied 193 women with acute vulvovaginal symptoms and 74 asymptomatic controls at three medical centers. The VS-Sense swab was administered intravaginally, and results were interpreted by a nurse. These results were compared with final clinical and laboratory diagnoses. In women with an elevated pH caused by bacterial vaginosis (BV), trichomonas, and other types of vaginitis, the VS-Sense test sensitivity and specificity were 82.3% (102 of 124) (95% CI 74.4%-88.5%) and 94.2% (129 of 137) (95% CI 88.8%-97.4%), respectively. There was an 86.2% (95% CI 81.3%-90.1%) overall agreement between pH paper and VS-Sense swab results. The VS-Sense test offers an alternative approach to measuring vaginal pH with nitrazine paper. Use of this simple, more rapid test may facilitate the diagnosis of vulvovaginitis.

  13. Evaluation of swabs, transport media, and specimen transport conditions for optimal detection of viruses by PCR.

    Science.gov (United States)

    Druce, Julian; Garcia, Katherine; Tran, Thomas; Papadakis, Georgina; Birch, Chris

    2012-03-01

    Depletion of swabs and viral transport medium during epidemics may prompt the use of unvalidated alternatives. Swabs collected and transported dry or in saline were compared to commercially available swab/medium combinations for PCR detection of influenza, enterovirus, herpes simplex virus, and adenovirus. Each was detected at an ambient temperature (22°C) and 4°C for 7 days. Detection of influenza on dry or saline swabs is important because of its capacity to cause outbreaks involving large numbers of cases.

  14. [The study of the contamination and the levels of Campylobacter spp. during the processing of selected types of foods].

    Science.gov (United States)

    Efimochkina, N R; Bykova, I B; Stetsenko, V V; Minaeva, L P; Pichugina, T V; Markova, Yu M; Korotkevich, Yu V; Kozak, S S; Sheveleva, S A

    2016-01-01

    The purpose of the work was to study the nature of the Campylobacter spp. contamination during the processing of food products of plant and animal origin (raw poultry and beef meat, raw milk, leafy salads, sliced raw vegetables). In the study of 148 samples 50 strains of Campylobacter spp. (33.8%) were found. For the main phenotypic characteristics they were identified as C. jejuni spp. jejuni and C. jejuni spp. doylei (over 75%). The highest level of detection of campylobacteria (over 45%) was set for raw poultry, including the carcasses of chickens broilers, quails, turkeys and their semi-finished products. 19 of the 27 strains from poultry were identified as C. jejuni. Among the strains isolated from the environment, including swabs from equipment surfaces, 91% of the isolates were also presented by C. jejuni. It was found that the investigated foodstuffs were characterized by high levels of contamination with bacteria of the family Enterobacteriaceae, the content of which was comparable with the identified values of total viable bacteria (cfu). Salmonella was detected in 19% of the investigated poultry samples and in 14.3% of raw cow milk. In the study of swabs from surfaces of poultry processing equipment, the frequency of detection of Campylobacter strains was 38.7%, Salmonella - 12.9%. Most commonly Campylobacter and Salmonella were detected in the zones of primary processing of poultry: the frequency of isolation of Salmonella in slaughter corner was 25%, Campylobacter - 43%. When testing the swabs taken in the cooking zone of «fast food» restaurants Campylobacter and Salmonella were not detected. For studying the swabs from equipment surfaces and the environment for the presence of Campylobacter spp. a modified technique of sampling was developed. The method includes a comprehensive analysis in the test area with the use of three types of media for transportation and incubation of Campylobacter spp. (Preston broth with blood, Brucella broth, Cary

  15. Contamination of Ethiopian paper currency notes from various food handlers with E. coli.

    Science.gov (United States)

    Hiko, Adem; Abdata, Kasahun; Muktar, Yimer; Woyesa, Mezene; Mohammed, Abdela

    2016-01-01

    Contamination rate of Ethiopian paper currency notes handled by various food handlers with Escherichia coli and antimicrobial susceptibility of the isolates was assessed. A total of 384 Ethiopian Birr (ETB) notes were randomly sampled from meat handlers at butchers, bread and the related food handlers at cafeteria, fruit and vegetables handlers at supermarket, and milk sellers both at open market and dairy station. Fifty control new currencies were also sampled from Commercial Bank of Ethiopia. Both surfaces of the currency were swabbed using wet sterile cotton. The swab was overnight incubated in buffered peptone water. A loop full was streaked on eosin methylene blue agar and followed by biochemical test on presumptive E. coli colonies. Randomly selected isolates were exposed to chloramphenicol (C-30 µg), neomycin (N-30 µg), oxytetracycline (OT-30 µg), polymyxin-B (PB-300 IU) and trimethoprim-sulfamethoxazole (SXT-1.25/23.75/µg) susceptibility using disc diffusion techniques. E. coli was not isolated from currency used as control. A total of 288 (75 %) currency notes were found carrying E. coli. E. coli prevalence was ranges from 67.2 % at open market milk sellers to 87.2 % at dairy station milk sellers; from 64.8 % on ETB 100 to 82.9 % on ETB 1. Differences were not observed in E. coli prevalence on currency notes from among almost all food handlers (P > 0.05). Susceptibility of tested isolates to each chloramphenicol, oxytetracycline and trimethoprim-sulfamethoxazole was 100 %, and to polymyxin-B was 97.3 %. High resistance (83.7 %) was observed to neomycin. The finding indicates, contaminated food can be a source of E. coli for further contamination of currency which again transfer through various foods ready for consumption.

  16. Low-cost monitoring of campylobacter in poultry houses by air sampling and quantitative PCR

    DEFF Research Database (Denmark)

    Søndergaard, Mette Sofie Rousing; Josefsen, Mathilde Hasseldam; Löfström, Charlotta

    2014-01-01

    approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain......The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two...... standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100...

  17. Bacteriological Profile and Antimicrobial Susceptibility Patterns of Bacteria Isolated from Pus/Wound Swab Samples from Children Attending a Tertiary Care Hospital in Kathmandu, Nepal

    Directory of Open Access Journals (Sweden)

    Salu Rai

    2017-01-01

    Full Text Available In Nepal, little is known about the microbiological profile of wound infections in children and their antimicrobial susceptibility patterns. Total of 450 pus/wound swab samples collected were cultured using standard microbiological techniques and the colonies grown were identified with the help of biochemical tests. The antimicrobial susceptibility testing was performed by Kirby-Bauer disc diffusion technique. Methicillin-resistant Staphylococcus aureus isolates were detected by using cefoxitin disc and confirmed by determining minimum inhibitory concentrations (MIC of oxacillin. 264 (59% samples were culture positive. The highest incidence of bacterial infections was noted in the age group of less than 1 year (76%. Out of 264 growth positive samples, Gram-positive bacteria were isolated from 162 (61% samples and Gram-negative bacteria were found in 102 (39% samples. Staphylococcus aureus (99% was the predominant Gram-positive bacteria isolated and Pseudomonas aeruginosa (44% was predominant Gram-negative bacteria. About 19% of S. aureus isolates were found to be methicillin-resistant MIC of oxacillin ranging from 4 μg/mL to 128 μg/mL. Among the children of Nepal, those of age less than 1 year were at higher risk of wound infections by bacteria. Staphylococcus aureus followed by Pseudomonas aeruginosa were the most common bacteria causing wound infections in children.

  18. Evaluation of self-swabbing coupled with a telephone health helpline as an adjunct tool for surveillance of influenza viruses in Ontario

    Directory of Open Access Journals (Sweden)

    D. McGolrick

    2016-09-01

    Full Text Available Abstract Background Calls to a telephone health helpline (THHL have been previously evaluated for the ability to monitor specific syndromes, such as fever and influenza-like-illness or gastrointestinal illness. This method of surveillance has been shown to be highly correlated with traditional surveillance methods, and to have potential for early detection of community-based illness. Self-sampling, or having a person take his/her own nasal swab, has also proven successful as a useful method for obtaining a specimen, which may be used for respiratory virus detection. Methods This study describes a self-swabbing surveillance system mediated by a nurse-led THHL in Ontario whereby syndromic surveillance concepts are used to recruit and monitor participants with influenza-like illness. Once recruited, participants collect a nasal specimen obtained by self-swabbing and submit for testing and laboratory confirmation. Enumeration of weekly case counts was used to evaluate the timeliness of the self-swabbing surveillance system through comparison to other respiratory virus and influenza surveillance systems in Ontario. The operational efficiency of the system was also evaluated. Results The mean and median number of days between the day that a participant called the THHL, to the day a package was received at the laboratory for testing were approximately 10.4 and 8.6 days, respectively. The time between self-swab collection and package reception was 4.9 days on average, with a median of 4 days. The self-swabbing surveillance system adequately captured the 2014 influenza B season in a timely manner when compared to other Ontario-based sources of influenza surveillance data from the same year; however, the emergence of influenza B was not detected any earlier than with these other surveillance systems. Influenza A surveillance was also evaluated. Using the THHL self-swabbing system, a peak in the number of cases for influenza A was observed approximately

  19. Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS

    Science.gov (United States)

    Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.

    2013-01-01

    Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.

  20. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    Science.gov (United States)

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L; Liang, Victoria; Martins, Claudia; Duarte, Silvy; Sarban, Natalia; Geddes, Patricia; Massa, Ana; Samios, Kathrin; Aboufadl, Siham; Verdon, Sophie; Pereria, Cynthia; Lacroix, Isabelle

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Gossypiboma – the retained surgical swab: An enduring clinical ...

    African Journals Online (AJOL)

    Retained abdominal swabs remain a difficult problem. This review ... and continues to date, despite advances .... difficult problem to eradicate even though .... to complete multiple emergency surgeries with no rest is great, ... The position.

  2. Bacterial recovery using sonication versus swabbing of titanium and stainless steel implants inoculated with Staphylococcus pseudintermedius or Pseudomonas aeruginosa.

    Science.gov (United States)

    Keeshen, Thomas; Case, J Brad; Wellehan, James F; Dujowich, Mauricio

    2017-09-12

    To evaluate the use of sonication to improve recovery of bacteria from metal discs infected with bacteria commonly associated with implant infections in veterinary medicine. In vitro study in which sterile titanium (Ti6Al4V) and stainless steel (AIS1316-L) discs were incubated with either Staphylococcus pseudintermedius or Pseudomonas aeruginosa for 24 hours. The following three groups were compared: 1) the sonication group involved immersing the discs in sterile saline and sonicating for five minutes; 2) the sham group was considered a negative control in which the discs were immersed in saline for five minutes without sonication; and 3) the swab group involved systematically swabbing the implant with a sterile culturette. All samples were plated on blood agar and incubated for 24 hours. Colonies were then counted and compared. For both species of bacteria, there was a significant increase in bacterial colonies isolated using sonication compared to the other two study groups (p = 0.0001). No differences in bacterial growth were found between the two types of metal implants. There was a significant increase in bacterial colony counts for S. pseudintermedius when comparing the swab group versus the sham group, but this was not significant for P. aeruginosa. Sonication significantly improves recovery of bacteria commonly associated with veterinary implant-associated surgical site infections compared to swabbing of implants in vitro. A prospective clinical evaluation is indicated to determine the in vivo efficacy of sonication in veterinary patients.

  3. Estimation of the sensitivity of various environmental sampling methods for detection of Salmonella in duck flocks.

    Science.gov (United States)

    Arnold, Mark E; Mueller-Doblies, Doris; Gosling, Rebecca J; Martelli, Francesca; Davies, Robert H

    2015-01-01

    Reports of Salmonella in ducks in the UK currently rely upon voluntary submissions from the industry, and as there is no harmonized statutory monitoring and control programme, it is difficult to compare data from different years in order to evaluate any trends in Salmonella prevalence in relation to sampling methodology. Therefore, the aim of this project was to assess the sensitivity of a selection of environmental sampling methods, including the sampling of faeces, dust and water troughs or bowls for the detection of Salmonella in duck flocks, and a range of sampling methods were applied to 67 duck flocks. Bayesian methods in the absence of a gold standard were used to provide estimates of the sensitivity of each of the sampling methods relative to the within-flock prevalence. There was a large influence of the within-flock prevalence on the sensitivity of all sample types, with sensitivity reducing as the within-flock prevalence reduced. Boot swabs (individual and pool of four), swabs of faecally contaminated areas and whole house hand-held fabric swabs showed the overall highest sensitivity for low-prevalence flocks and are recommended for use to detect Salmonella in duck flocks. The sample type with the highest proportion positive was a pool of four hair nets used as boot swabs, but this was not the most sensitive sample for low-prevalence flocks. All the environmental sampling types (faeces swabs, litter pinches, drag swabs, water trough samples and dust) had higher sensitivity than individual faeces sampling. None of the methods consistently identified all the positive flocks, and at least 10 samples would be required for even the most sensitive method (pool of four boot swabs) to detect a 5% prevalence. The sampling of dust had a low sensitivity and is not recommended for ducks.

  4. HIV-1 and herpes simplex virus type-2 genital shedding among co-infected women using self-collected swabs in Chiang Rai, Thailand.

    Science.gov (United States)

    Forhan, S E; Dunne, E F; Sternberg, M R; Whitehead, S J; Leelawiwat, W; Thepamnuay, S; Chen, C; Evans-Strickfaden, Tt; McNicholl, J M; Markowitz, L E

    2012-08-01

    We analysed 528 genital self-collected swabs (SCS) from 67 HIV-1 and herpes simplex virus type-2 (HSV-2) co-infected women collected during the placebo month of a randomized crossover clinical trial of suppressive acyclovir in Chiang Rai, Thailand. In this first longitudinal study of HIV-1 and HSV-2 co-infected women using genital SCS specimens, we found frequent mucosal HIV-1 shedding. Overall, 372 (70%) swabs had detectable HIV-1 RNA with median HIV-1 viral load of 2.61 log(10) copies/swab. We found no statistically significant association between detectable HIV-1 RNA and HSV-2 DNA in the same SCS specimen (adjusted odds ratio [aOR] 1.40; 95% confidence intervals [CI], 0.78-2.60, P = 0.25). Only baseline HIV-1 plasma viral load was independently associated with genital HIV-1 RNA shedding (aOR, 7.6; 95% CI, 3.3-17.2, P genital sampling, and inclusion of genital sites other than the cervix.

  5. Prevalence and characterization of methicillin-resistant Staphylococcus aureus isolates in food industry workers.

    Science.gov (United States)

    Caggiano, G; Dambrosio, A; Ioanna, F; Balbino, S; Barbuti, G; De Giglio, O; Diella, G; Lovero, G; Rutigliano, S; Scarafile, G; Baldassarre, A; Vimercati, L; Musti, M; Montagna, M T

    2016-01-01

    Methicillin-resistant S. aureus (MRSA) is a pathogen spread not only in the hospital environment but also in the community and amongst livestock (LA-MRSA). LA-MRSA can be transmitted to humans that live in close contact with MRSA-colonized animals, and human colonization and/or infection has been reported worldwide, particularly among those involved with livestock farming. In this study the authors evaluated the prevalence of S. aureus and MRSA among healthy carriers who worked in the food industry in Apulia, Southern Italy. Nasal swabs were taken from pasta and pork industry workers. All swab samples were subjected to tests for the isolation, identification and typing of S. aureus and MRSA strains. The identification of the strains was confirmed by molecular assessment using multiplex-PCR for the amplification of the nuc and mecA genes. The strains identified as MRSA were then subjected to a PCR protocol for the characterization of sequence type ST398. In total 26.3% of examined nasal swabs were positive for S. aureus, 8.2% of them were methicillin resistant strains and 28.5% of MRSA isolates were characterized as ST398. The MRSA prevalence among pork factory workers was 3% , whereas among the pasta operators the prevalence was 11.5. The presence of S. aureus and MRSA among food workers represents a public health risk. Further, considering the dissemination of S. aureus and MRSA among non-nosocomial environments, including communities and livestock, careful surveillance and continuous monitoring of the emergence of MRSA is fundamental for safeguarding public health.

  6. Challenging genosensors in food samples: The case of gluten determination in highly processed samples.

    Science.gov (United States)

    Martín-Fernández, Begoña; de-los-Santos-Álvarez, Noemí; Martín-Clemente, Juan Pedro; Lobo-Castañón, María Jesús; López-Ruiz, Beatriz

    2016-01-01

    Electrochemical genosensors have undergone an enormous development in the last decades, but only very few have achieved a quantification of target content in highly processed food samples. The detection of allergens, and particularly gluten, is challenging because legislation establishes a threshold of 20 ppm for labeling as gluten-free but most genosensors expresses the results in DNA concentration or DNA copies. This paper describes the first attempt to correlate the genosensor response and the wheat content in real samples, even in the case of highly processed food samples. A sandwich-based format, comprising a capture probe immobilized onto the screen-printed gold electrode, and a signaling probe functionalized with fluorescein isothiocyanate (FITC), both hybridizing with the target was used. The hybridization event was electrochemically monitored by adding an anti-FITC peroxidase (antiFITC-HRP) and its substrate, tetramethylbenzidine. Binary model mixtures, as a reference material, and real samples have been analyzed. DNA from food was extracted and a fragment encoding the immunodominant peptide of α2-gliadin amplified by a tailored PCR. The sensor was able to selectively detect toxic cereals for celiac patients, such as different varieties of wheat, barley, rye and oats, from non-toxic plants. As low as 0.001% (10 mg/kg) of wheat flour in an inert matrix was reliably detected, which directly compete with the current method of choice for DNA detection, the real-time PCR. A good correlation with the official immunoassay was found in highly processed food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Different methods for volatile sampling in mammals.

    Directory of Open Access Journals (Sweden)

    Marlen Kücklich

    Full Text Available Previous studies showed that olfactory cues are important for mammalian communication. However, many specific compounds that convey information between conspecifics are still unknown. To understand mechanisms and functions of olfactory cues, olfactory signals such as volatile compounds emitted from individuals need to be assessed. Sampling of animals with and without scent glands was typically conducted using cotton swabs rubbed over the skin or fur and analysed by gas chromatography-mass spectrometry (GC-MS. However, this method has various drawbacks, including a high level of contaminations. Thus, we adapted two methods of volatile sampling from other research fields and compared them to sampling with cotton swabs. To do so we assessed the body odor of common marmosets (Callithrix jacchus using cotton swabs, thermal desorption (TD tubes and, alternatively, a mobile GC-MS device containing a thermal desorption trap. Overall, TD tubes comprised most compounds (N = 113, with half of those compounds being volatile (N = 52. The mobile GC-MS captured the fewest compounds (N = 35, of which all were volatile. Cotton swabs contained an intermediate number of compounds (N = 55, but very few volatiles (N = 10. Almost all compounds found with the mobile GC-MS were also captured with TD tubes (94%. Hence, we recommend TD tubes for state of the art sampling of body odor of mammals or other vertebrates, particularly for field studies, as they can be easily transported, stored and analysed with high performance instruments in the lab. Nevertheless, cotton swabs capture compounds which still may contribute to the body odor, e.g. after bacterial fermentation, while profiles from mobile GC-MS include only the most abundant volatiles of the body odor.

  8. Real-time pathogen monitoring during enrichment: a novel nanotechnology-based approach to food safety testing.

    Science.gov (United States)

    Weidemaier, Kristin; Carruthers, Erin; Curry, Adam; Kuroda, Melody; Fallows, Eric; Thomas, Joseph; Sherman, Douglas; Muldoon, Mark

    2015-04-02

    We describe a new approach for the real-time detection and identification of pathogens in food and environmental samples undergoing culture. Surface Enhanced Raman Scattering (SERS) nanoparticles are combined with a novel homogeneous immunoassay to allow sensitive detection of pathogens in complex samples such as stomached food without the need for wash steps or extensive sample preparation. SERS-labeled immunoassay reagents are present in the cultural enrichment vessel, and the signal is monitored real-time through the wall of the vessel while culture is ongoing. This continuous monitoring of pathogen load throughout the enrichment process enables rapid, hands-free detection of food pathogens. Furthermore, the integration of the food pathogen immunoassay directly into the enrichment vessel enables fully biocontained food safety testing, thereby significantly reducing the risk of contaminating the surrounding environment with enriched pathogens. Here, we present experimental results showing the detection of E. coli, Salmonella, or Listeria in several matrices (raw ground beef, raw ground poultry, chocolate milk, tuna salad, spinach, brie cheese, hot dogs, deli turkey, orange juice, cola, and swabs and sponges used to sample a stainless steel surface) using the SERS system and demonstrate the accuracy of the approach compared to plating results. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Cervical Cancer Screening Preferences Among Trans-Masculine Individuals: Patient-Collected Human Papillomavirus Vaginal Swabs Versus Provider-Administered Pap Tests.

    Science.gov (United States)

    McDowell, Michal; Pardee, Dana J; Peitzmeier, Sarah; Reisner, Sari L; Agénor, Madina; Alizaga, Natalie; Bernstein, Ida; Potter, Jennifer

    2017-08-01

    Trans-masculine (TM, i.e., persons who have a masculine spectrum gender identity, but were assigned female sex at birth) individuals face disparities in cervical cancer screening rates compared to cisgender women. Some unique barriers to screening in this population are specific to Pap tests. Introduction of self-collected frontal (i.e., vaginal) swabs for human papillomavirus (HPV) testing as a screening strategy may obviate these barriers. This study elucidates cervical cancer screening preferences among TM individuals. TM individuals participated in in-depth interviews (n = 31) and online surveys (n = 32) to explore perceptions and experiences regarding cervical cancer screening, including the acceptability of self-collected frontal HPV swabs for cervical cancer screening compared to provider-administered Pap tests. Provider-collected frontal HPV swab acceptability was also explored. Most TM individuals (94% in-person and 91% online participants) preferred either the self- or provider-collected frontal HPV swab to the Pap test. Participants perceived self- and provider-collected frontal HPV swabs to be less invasive, provoke less gender discordance, and promote a greater sense of agency compared to Pap tests. However, some participants expressed concern about HPV swab accuracy and, regarding the self-collected swab, discomfort about the need to engage with genitals they may not want to acknowledge. Individuals who reported positive provider relationships found Pap tests and provider-collected frontal swabs more acceptable than those who did not. Frontal HPV swabs have the potential to promote regular cervical cancer screening among TM individuals and to narrow screening disparities. Work is ongoing to establish swab accuracy and develop shared decision-making tools.

  10. Plasticizers in total diet samples, baby food and infant formulae

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Breindahl, T.

    2000-01-01

    The plasticizers di-n-butylphthalate (DBP), butylbenzylphthalate (BBP), di-2-(ethylhexyl)phthalate (DEHP) and di-2-(ethylhexyl)adipate (DEHA) were analysed in 29 total diet samples, in 11 samples of baby food and in 11 samples of infant formulae. In all of the total diet samples the presence of one...... as in infant formulae. The calculated mean maximum intakes of the individual compounds from the total diet samples were below 10% of the restrictions proposed by the EU Scientific Committee for Food (SCF), and the spread in individual intakes was considerable. DEHP was the plasticizer determined most...

  11. Validation of a same-day real-time PCR method for screening of meat and carcass swabs for Salmonella

    DEFF Research Database (Denmark)

    Löfström, Charlotta; Krause, Michael; Josefsen, Mathilde Hartmann

    2009-01-01

    of the published PCR methods for Salmonella have been validated in collaborative studies. This study describes a validation including comparative and collaborative trials, based on the recommendations from the Nordic organization for validation of alternative microbiological methods (NordVal) of a same-day, non....... Partly based on results obtained in this study, the method has obtained NordVal approval for analysis of Salmonella in meat and carcass swabs. The PCR method was transferred to a production laboratory and the performance was compared with the BAX Salmonella test on 39 pork samples artificially...... contaminated with Salmonella. There was no significant difference in the results obtained by the two methods. Conclusion: The real-time PCR method for detection of Salmonella in meat and carcass swabs was validated in comparative and collaborative trials according to NordVal recommendations. The PCR method...

  12. Development, validation and testing of a skin sampling method for assessment of metal exposure.

    Science.gov (United States)

    Erfani, Behnaz; Midander, Klara; Lidén, Carola; Julander, Anneli

    2017-07-01

    Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm 2 ) were sampled with 1% HNO 3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO 3 and analysed by inductively coupled plasma mass spectrometry. The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm 2 , from 0.00014 to -0.0020 µg/cm 2 and from 0.00048 to -0.027 µg/cm 2 for nickel, cobalt, and chromium, respectively. The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Technical basis for using nose swab bioassay data for early internal dose assessment

    International Nuclear Information System (INIS)

    Guilmette, Raymond A.; Bertelli, Luiz; Miller, Guthrie; Little, Tom T.

    2007-01-01

    One of the challenges to the dose assessment team in response to an inhalation incident in the workplace is to provide the occupational physicians, operational radiation protection personnel and line managers with early estimates of radionuclide intakes so that appropriate consequence management and mitigation can be done. For radionuclides such as Pu, where in vivo counting is not adequately sensitive, other techniques such as the measurement of removable radionuclide from the nasal airway passages can be used. At Los Alamos National Laboratory (LANL), nose swabs of the ET 1 region have been used routinely as a first response to airborne Pu releases in the workplace, as well as for other radionuclides. This paper presents the results of analysing over 15 years of nose swab data, comparing these with dose assessments performed using the Bayesian methods developed at LANL. The results provide empirical support for using nose swab data for early dose assessments. For Pu, a rule of thumb is a dose factor of 0.8 mSv Bq -1 , assuming a linear relationship between nasal swab activity and committed effective dose equivalent. However, this value is specific to the methods and models used at LANL, and should not be applied directly without considering possible differences in measurement and calculation methods. (authors)

  14. SWAB guidelines for antimicrobial therapy of acute infectious diarrhoea

    NARCIS (Netherlands)

    Bos, J. C.; Schultsz, C.; Vandenbroucke-Graulsz, C. M. J.; Speelman, P.; Prins, J. M.

    2006-01-01

    The Dutch Working Party on Antibiotic Policy (SWAB: Stichting Werkgroep Antibioticabeleid) develops evidence-based guidelines for the use of antibiotics in hospitalised adults. In this article we discuss the guideline on antibiotic treatment of acute infectious diarrhoea (AID). AID can be subdivided

  15. Sample preparation combined with electroanalysis to improve simultaneous determination of antibiotics in animal derived food samples.

    Science.gov (United States)

    da Silva, Wesley Pereira; de Oliveira, Luiz Henrique; Santos, André Luiz Dos; Ferreira, Valdir Souza; Trindade, Magno Aparecido Gonçalves

    2018-06-01

    A procedure based on liquid-liquid extraction (LLE) and phase separation using magnetically stirred salt-induced high-temperature liquid-liquid extraction (PS-MSSI-HT-LLE) was developed to extract and pre-concentrate ciprofloxacin (CIPRO) and enrofloxacin (ENRO) from animal food samples before electroanalysis. Firstly, simple LLE was used to extract the fluoroquinolones (FQs) from animal food samples, in which dilution was performed to reduce interference effects to below a tolerable threshold. Then, adapted PS-MSSI-HT-LLE protocols allowed re-extraction and further pre-concentration of target analytes in the diluted acid samples for simultaneous electrochemical quantification at low concentration levels. To improve the peak separation, in simultaneous detection, a baseline-corrected second-order derivative approach was processed. These approaches allowed quantification of target FQs from animal food samples spiked at levels of 0.80 to 2.00 µmol L -1 in chicken meat, with recovery values always higher than 80.5%, as well as in milk samples spiked at 4.00 µmol L -1 , with recovery values close to 70.0%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Experimental Design for a Macrofoam-Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-05

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam-swab sampling at low concentrations.

  17. Experimental Design for a Macrofoam Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Hutchison, Janine R.

    2014-04-16

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam swab sampling at low concentrations.

  18. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  19. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  20. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  1. Automated, simple, and efficient influenza RNA extraction from clinical respiratory swabs using TruTip and epMotion.

    Science.gov (United States)

    Griesemer, Sara B; Holmberg, Rebecca; Cooney, Christopher G; Thakore, Nitu; Gindlesperger, Alissa; Knickerbocker, Christopher; Chandler, Darrell P; St George, Kirsten

    2013-09-01

    Rapid, simple and efficient influenza RNA purification from clinical samples is essential for sensitive molecular detection of influenza infection. Automation of the TruTip extraction method can increase sample throughput while maintaining performance. To automate TruTip influenza RNA extraction using an Eppendorf epMotion robotic liquid handler, and to compare its performance to the bioMerieux easyMAG and Qiagen QIAcube instruments. Extraction efficacy and reproducibility of the automated TruTip/epMotion protocol was assessed from influenza-negative respiratory samples spiked with influenza A and B viruses. Clinical extraction performance from 170 influenza A and B-positive respiratory swabs was also evaluated and compared using influenza A and B real-time RT-PCR assays. TruTip/epMotion extraction efficacy was 100% in influenza virus-spiked samples with at least 745 influenza A and 370 influenza B input gene copies per extraction, and exhibited high reproducibility over four log10 concentrations of virus (extraction were also positive following TruTip extraction. Overall Ct value differences obtained between TruTip/epMotion and easyMAG/QIAcube clinical extracts ranged from 1.24 to 1.91. Pairwise comparisons of Ct values showed a high correlation of the TruTip/epMotion protocol to the other methods (R2>0.90). The automated TruTip/epMotion protocol is a simple and rapid extraction method that reproducibly purifies influenza RNA from respiratory swabs, with comparable efficacy and efficiency to both the easyMAG and QIAcube instruments. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Analysis of DNA evidence recovered from epithelial cells in penile swabs.

    Science.gov (United States)

    Drobnic, Katja

    2003-06-01

    In the rape case presented here, no semen, hair, or other biological evidence were left by the perpetuator at the crime scene or on the victim. The alleged assailant was arrested soon after the crime. A classical stain recovery technique using cotton swab moistened with sterile water was taken for recovering potential female epithelial cells and leukocytes deposited on the alleged assailant's penis during sexual assault. The organic method used for DNA extraction was quantified according to the slot-blot procedure and amplified at 9 and 15 polymorphic loci. Penile swab revealed a DNA profile of mixed origin. In addition to the suspect's DNA profile, DNA contribution from the victim was identified as a minor component in the mixture. Frequency of the profile resulted in a value of 5 x 10(-14) for the multiplex systems AmpFlSTR Plus and 2.5 x 10(-18) for the multiplex system PowerPlex 16, taking into account only non-overlapping alleles between the suspect and the victim from the minor component in the DNA mixture. Moreover, three additional alleles were observed at D21S11 locus by use of PowerPlex and STR SGM plus primers, which could not belong to the suspect. The victim's DNA profile showed the same three-banded genotype at this locus. The same pattern was detected when the victim's saliva or blood were used as reference samples. Our laboratory finding was consistent with the police report that the victim was a person with Down syndrome, a human genetic disease mainly resulting from trisomy (triplication) of the 21 chromosome.

  3. Detection and Serogrouping of Dichelobacter nodosus Infection by Use of Direct PCR from Lesion Swabs To Support Outbreak-Specific Vaccination for Virulent Footrot in Sheep.

    Science.gov (United States)

    McPherson, Andrew S; Dhungyel, Om P; Whittington, Richard J

    2018-04-01

    Virulent footrot is an economically significant disease in most sheep-rearing countries. The disease can be controlled with vaccine targeting the fimbriae of virulent strains of the essential causative agent, Dichelobacter nodosus However, the bacterium is immunologically heterogeneous, and 10 distinct fimbrial serogroups have been identified. Ideally, in each outbreak the infecting strains would be cultured and serogrouped so that the appropriate serogroup-specific mono- or bivalent vaccine could be administered, because multivalent vaccines lack efficacy due to antigenic competition. If clinical disease expression is suspected to be incomplete, culture-based virulence tests are required to confirm the diagnosis, because control of benign footrot is economically unjustifiable. Both diagnosis and vaccination are conducted at the flock level. The aims of this study were to develop a PCR-based procedure for detecting and serogrouping D. nodosus directly from foot swabs and to determine whether this could be done accurately from the same cultured swab. A total of 269 swabs from the active margins of foot lesions of 261 sheep in 12 Merino sheep flocks in southeastern Australia were evaluated. DNA extracts taken from putative pure cultures of D. nodosus and directly from the swabs were evaluated in PCR assays for the 16S rRNA and fimA genes of D. nodosus Pure cultures were tested also by the slide agglutination test. Direct PCR using extracts from swabs was more sensitive than culture for detecting and serogrouping D. nodosus strains. Using the most sensitive sample collection method of the use of swabs in lysis buffer, D. nodosus was more likely to be detected by PCR in active than in inactive lesions, and in lesions with low levels of fecal contamination, but lesion score was not a significant factor. PCR conducted on extracts from swabs in modified Stuart's transport medium that had already been used to inoculate culture plates had lower sensitivity. Therefore, if

  4. Current Microbial Isolates from Wound Swab and Their Susceptibility Pattern in a Private Medical College Hospital in Dhaka city

    Directory of Open Access Journals (Sweden)

    Shahin Sultana

    2015-03-01

    Full Text Available Background: Wound infection is one of the major health problems that are caused and aggravated by the invasion of pathogenic organisms where empiric treatment is routine. Objective: To isolate and identify the bacteria causing wound infection and to determine the antimicrobial susceptibility pattern. Materials and method: A total of 263 wound swab and pus samples were collected during the period of January to December 2012 from Delta Medical College and Hospital, Dhaka, Bangladesh. Swabs from the wound were inoculated on appropriate media and cultured and the isolates were identified by standard procedures as needed. Antimicrobial susceptibility testing was performed by disk diffusion method according to ‘The Clinical Laboratory Standard Institute’ guidelines. Results: In this study 220 bacterial isolates were recovered from 263 samples showing an isolation rate of 83.65%. The predominant bacteria isolated from infected wounds were Staphylococcus aureus 89 (40.45% followed by Escherichia coli 62 (28.18%, Pseudomonas aeruginosa 34 (15.45%, Enterococci 18 (8.18%, Acinetobacter 5 (2.27%, Klebsiella 9 (4.09% and Proteus 3 (3.36%. Staphylococcus aureus was sensitive to linezolid (94.38%, fusidic acid (91.01%, vancomycin (87.64%, amikacin (74.15% and gentamicin (73.03%. Among the Gram negative isolates Escherichia coli was predominant and showed sensitivity to imipenem (93.54% amikacin (83.87% colistin (53.22% and piperacillin and tazobactum (53.22% and pseudomonas showed sensitivity to amikacin (73.52%, imipenem (70.58% and colistin (70.58%. Conclusion: Staphylococcus aureus was the most frequently isolated pathogen from wound swab and the antibiotic sensitivity pattern of various isolates help to assist the clinician in appropriate selection of empirical antibiotics against wound infection.

  5. Viral, Serological, and Antioxidant Investigations of Equine Rhinitis A Virus in Serum and Nasal Swabs of Commercially Used Horses in Poland

    Directory of Open Access Journals (Sweden)

    Barbara Bażanów

    2018-01-01

    Full Text Available Background. Equine rhinitis A virus (ERAV is considered to be an important pathogen in horses, but relatively few studies are available. Aims. The purpose of this study was to verify ERAV seroprevalence in selected horses in Poland, in addition to correlation between ERAV and age and sex of analysed animals and the antioxidant status. Methods. The material collected from clinically healthy horses was tested using the VNT (353 serum samples and virus isolation method (44 nasal swabs. 27 serum samples with antibody titers between 0 and ≥1 : 2048 were chosen for further analysis. The study was conducted in group 1 (ERAV titer ≤ 64 and group 2 (ERAV titer > 64. Results. Seroneutralisation tests showed positive results in 72% of serum samples. No significant correlation between ERAV seropositive results and selected biochemical indicators was observed. Group 2 had statistically higher concentrations of SOD and CuZnSOD than the analysed group 1. Conclusions. ERAV was not detected in the nasal swab samples. Antioxidant parameters did not significantly vary between horses of different breed, sex, or age. The ERAV virus had an impact on plasma total SOD and Cu/Zn SOD activity in horses in early stages of convalescence.

  6. DISTRIBUTION OF COAGULASE-NEGATIVE STAPHYLOCOCCI SPECIES ON TEAT SKIN AND IN MILK SAMPLES FROM DAIRY COWS IN AUTOMATIC MILKING SYSTEMS

    DEFF Research Database (Denmark)

    Mahmmod, Yasser Saadeldien Ibrahim; Svennesen, Line; Pedersen, Karl

    ) to identify the predisposing cow level risk factors for specific CNS IMI and teat colonization.In each herd, 30- 40 cows with somatic cell counts > 200,000 cells/ml in the previous milk recording are randomly selected and teat skin swabs and aseptic quarter foremilk samples are taken. Teat skin swabs...... are collected using a modified wet-dry method. First a wet swab immersed in ¼ Ringer’s solution followed by a dry swab are rotated 360° around the teat canal orifice and both swab tips transferred into one tube with 2 ml of ¼ Ringer’s solution. Samples are transported on ice for culturing in the laboratory...

  7. Norovirus Transmission between Hands, Gloves, Utensils, and Fresh Produce during Simulated Food Handling

    Science.gov (United States)

    Aho, E.; Mikkelä, A.; Ranta, J.; Tuominen, P.; Rättö, M.; Maunula, L.

    2014-01-01

    Human noroviruses (HuNoVs), a leading cause of food-borne gastroenteritis worldwide, are easily transferred via ready-to-eat (RTE) foods, often prepared by infected food handlers. In this study, the transmission of HuNoV and murine norovirus (MuNoV) from virus-contaminated hands to latex gloves during gloving, as well as from virus-contaminated donor surfaces to recipient surfaces after simulated preparation of cucumber sandwiches, was inspected. Virus transfer was investigated by swabbing with polyester swabs, followed by nucleic acid extraction from the swabs with a commercial kit and quantitative reverse transcription-PCR. During gloving, transfer of MuNoV dried on the hand was observed 10/12 times. HuNoV, dried on latex gloves, was disseminated to clean pairs of gloves 10/12 times, whereas HuNoV without drying was disseminated 11/12 times. In the sandwich-preparing simulation, both viruses were transferred repeatedly to the first recipient surface (left hand, cucumber, and knife) during the preparation. Both MuNoV and HuNoV were transferred more efficiently from latex gloves to cucumbers (1.2% ± 0.6% and 1.5% ± 1.9%) than vice versa (0.7% ± 0.5% and 0.5% ± 0.4%). We estimated that transfer of at least one infective HuNoV from contaminated hands to the sandwich prepared was likely to occur if the hands of the food handler contained 3 log10 or more HuNoVs before gloving. Virus-contaminated gloves were estimated to transfer HuNoV to the food servings more efficiently than a single contaminated cucumber during handling. Our results indicate that virus-free food ingredients and good hand hygiene are needed to prevent HuNoV contamination of RTE foods. PMID:24951789

  8. Migration of a retained surgical swab into the jejunum in a dog.

    Science.gov (United States)

    Day, J L; Pechman, R D; Bahr, R J

    2012-12-01

    A two-year-old spayed female shih-tzu was referred with a 10-month history of lethargy, chronic diarrhoea and weight loss. On presentation, a partial response to antibiotics was noted. Physical examination revealed an abdominal mass, and serum biochemistry and haematology revealed a mature neutrophilia, hypoalbuminaemia and a non-regenerative anaemia. Contrast radiography and abdominal ultrasound were suggestive of an intraluminal foreign body. Exploratory laparotomy revealed a surgical swab in the lumen of the jejunum that was associated with severe adhesions. Histopathology showed evidence of transmural migration of the swab from the peritoneal cavity to the lumen of the jejunum. © 2012 British Small Animal Veterinary Association.

  9. [Analysis on contamination of aflatoxins in food samples in Shaanxi Province from 2012-2015].

    Science.gov (United States)

    Hu, Jiawei; Tian, Li; Wang, Caixia; Qiao, Haiou; Wang, Minjuan

    2016-09-01

    To investigate the contamination of aflatoxins in food in Shaanxi Province, and provide the basic data of dietary intakes of aflatoxins for food safety assessment. In year 2012- 2015, 1007 food samples of eight kinds of food including grains, beans, vegetable oil, nuts and seeds, condiment, liquor, tea and infants' food were collected randomly from ten cities, and determined with UPLC. 1007 samples were detected aflatoxins and the total detection rate was 10. 7%. The detection range was 0. 070- 323 μg / kg, with the mean value of 2. 34 μg / kg. Among all food samples, only peanut products were more seriously polluted than other kinds of foods. The overall level of aflatoxins contamination in market food is low, but peanut products might be the contaminated foods with aflatoxins in Shaanxi Province, and should be given more attention.

  10. Rapid diagnosis of diarrhea caused by Shigella sonnei using dipsticks; comparison of rectal swabs, direct stool and stool culture.

    Directory of Open Access Journals (Sweden)

    Claudia Duran

    Full Text Available BACKGROUND: We evaluated a dipstick test for rapid detection of Shigella sonnei on bacterial colonies, directly on stools and from rectal swabs because in actual field situations, most pathologic specimens for diagnosis correspond to stool samples or rectal swabs. METHODOLOGY/PRINCIPAL FINDINGS: The test is based on the detection of S. sonnei lipopolysaccharide (LPS O-side chains using phase I-specific monoclonal antibodies coupled to gold particles, and displayed on a one-step immunochromatographic dipstick. A concentration as low as 5 ng/ml of LPS was detected in distilled water and in reconstituted stools in 6 minutes. This is the optimal time for lecture to avoid errors of interpretation. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 4 x 10(6 CFU/ml of S. sonnei. The specificity was 100% when tested with a battery of Shigella and different unrelated strains. When tested on 342 rectal swabs in Chile, specificity (281/295 was 95.3% (95% CI: 92.9% - 97.7% and sensitivity (47/47 was 100%. Stool cultures and the immunochromatographic test showed concordant results in 95.5 % of cases (328/342 in comparative studies. Positive and negative predictive values were 77% (95% CI: 65% - 86.5% and 100% respectively. When tested on 219 stools in Chile, Vietnam, India and France, specificity (190/198 was 96% (95% CI 92%-98% and sensitivity (21/21 was 100%. Stool cultures and the immunochromatographic test showed concordant results in 96.3 % of cases (211/219 in comparative studies. Positive and negative predictive values were 72.4% (95% CI 56.1%-88.6% and 100 %, respectively. CONCLUSION: This one-step dipstick test performed well for diagnosis of S. sonnei both on stools and on rectal swabs. These data confirm a preliminary study done in Chile.

  11. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm²). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD₉₅ was lowest for glass (0.429 CFU/cm² with BAS and 0.341 CFU/cm² with BG) and highest for vinyl tile (0.919 CFU/cm² with BAS and 0.917 CFU/cm² with BG). These mRV-PCR LOD₉₅ values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm² and BG: 0.820 to 1.489 CFU/cm²). The FNR and LOD₉₅ values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  12. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L.D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm2). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD95 was lowest for glass (0.429 CFU/cm2 with BAS and 0.341 CFU/cm2 with BG) and highest for vinyl tile (0.919 CFU/cm2 with BAS and 0.917 CFU/cm2 with BG). These mRV-PCR LOD95 values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm2 and BG: 0.820 to 1.489 CFU/cm2). The FNR and LOD95 values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  13. Escherichia coli and coliforms level of food utensils at food premises in Kuala Pilah, Malaysia

    Science.gov (United States)

    Saipullizan, Siti Nurul Ain; Mutalib, Sahilah Abd.; Sedek, Razalee

    2018-04-01

    The aim of this study was to evaluate the Escherichia coli and coliforms level of food utensils at sixty food premises in Kuala Pilah, Malaysia. The swab technique was used to investigate the presence of E. coli and coliforms on 180 of food utensils (chopping boards: 60, knives: 60 and dish plates: 60). The results indicated that 180 of food utensils were contaminated with E. coli and coliforms. More than 60% of the coliforms were exceeded the acceptable limit compared to E. coli on the food utensils. The one-way ANOVA analysis demonstrated that the presence of E. coli and coliforms differed significantly among the three types of food utensils (knives, chopping boards, and dish plates). In conclusion, this study revealed that there are hygiene issues exist in every food premises. The food utensils are safe to use during the food preparation if the presence of E. coli and coliforms are not exceed the acceptable limit. Thus, it is recommended that the food handlers in the food premises should improve effective cleaning and sanitizing of food utensils in their daily work.

  14. Assessment of two different types of sample for the early detection and isolation of thermophilic Campylobacter in broiler farms.

    Science.gov (United States)

    Urdaneta, Saulo; Dolz, Roser; Cerdà-Cuéllar, Marta

    2015-01-01

    In order to assess the optimal method for the early detection and isolation of thermophilic Campylobacter in broilers at farm level, two types of samples were compared: caecal contents obtained by necropsy and cloacal swabs transported in charcoal Amies medium. The study was conducted in five batches of broilers from five different farms, where weekly samples (caecal contents and cloacal swabs) from 30 birds were obtained. Samples were plated onto selective agar (modified charcoal cefoperazone desoxycholate agar, mCCDA) for Campylobacter isolation. Four out of five batches were positive for Campylobacter. No marked differences in sensitivity of both sample types were observed. However, a higher percentage of positive birds were detected when cloacal swabs were used. The results show that cloacal swab samples are adequate, and in some cases even better than caecal samples for the early detection of Campylobacter in broiler flocks at farm level. Also, this sample avoids sacrificing birds to test Campylobacter, which not only allows saving time in sample collection, transportation and processing at the laboratory, but also improves bird welfare and cost of sampling.

  15. Influence of UV Treatment on the Food Safety Status of a Model Aquaponic System

    Directory of Open Access Journals (Sweden)

    Sai Deepikaa Elumalai

    2017-01-01

    Full Text Available Few microbial studies in aquaponics, a growing trend in food production, have been conducted to determine food safety status. The aim of this study was to determine the food safety status and the effectiveness of ultraviolet treatment (15 W, luminous flux of 900 lm as a food safety intervention in reducing the microbial loads of the water system in a model aquaponic unit growing lettuce, basil, and barramundi (Australian Sea Bass. Sweet basil, bibb lettuce, water samples, and fish swabs were collected throughout the 118-day production period, and microbial analysis was conducted in triplicate for the presence of E. coli O157:H7, Salmonella spp., and the prevalence of aerobic plate counts (APC, coliforms, and fecal coliforms in these systems. Absence of foodborne pathogens was confirmed using ELISA technology and enumeration through petrifilms (coliform/E. coli. A significant increase was observed in aerobic plate counts over the trial period (1 to 3 log10 CFU·mL−1 in the presence and absence of UV (p > 0.05. Ultraviolet treatment did not significantly reduce the APC or coliform counts when compared to the control system samples. Future work should focus on improving the unit design, the evaluation of bio-solid filtration, and other food safety interventions.

  16. Acrylamide exposure among Turkish toddlers from selected cereal-based baby food samples.

    Science.gov (United States)

    Cengiz, Mehmet Fatih; Gündüz, Cennet Pelin Boyacı

    2013-10-01

    In this study, acrylamide exposure from selected cereal-based baby food samples was investigated among toddlers aged 1-3 years in Turkey. The study contained three steps. The first step was collecting food consumption data and toddlers' physical properties, such as gender, age and body weight, using a questionnaire given to parents by a trained interviewer between January and March 2012. The second step was determining the acrylamide levels in food samples that were reported on by the parents in the questionnaire, using a gas chromatography-mass spectrometry (GC-MS) method. The last step was combining the determined acrylamide levels in selected food samples with individual food consumption and body weight data using a deterministic approach to estimate the acrylamide exposure levels. The mean acrylamide levels of baby biscuits, breads, baby bread-rusks, crackers, biscuits, breakfast cereals and powdered cereal-based baby foods were 153, 225, 121, 604, 495, 290 and 36 μg/kg, respectively. The minimum, mean and maximum acrylamide exposures were estimated to be 0.06, 1.43 and 6.41 μg/kg BW per day, respectively. The foods that contributed to acrylamide exposure were aligned from high to low as bread, crackers, biscuits, baby biscuits, powdered cereal-based baby foods, baby bread-rusks and breakfast cereals. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Efficacy of an anaerobic swab transport system to maintain aerobic and anaerobic microorganism viability after storage at -80 degrees C.

    Science.gov (United States)

    Musser, Jeffrey M B; Gonzalez, Rosa

    2011-01-01

    An Amies agar gel swab transport system was evaluated for its ability to maintain bacterial viability and relative quantity after freezing at -80°C. Nine American Type Culture Collection (ATCC) bacterial strains were used: 3 anaerobic strains (Propionibacterium acnes, Peptostreptococcus anaerobius, and Clostridium sporogenes) and 6 facultative or strict aerobic bacterial strains (Stenotrophomonas maltophilia, Escherichia coli ([ATCC 25922 and ATCC 11775], Salmonella enterica subsp. enterica serovar Typhimurium, Staphylococcus saprophyticus, and Lactobacillus casei). The bacterial species were chosen because they corresponded to bacteria identified in psittacine feces and cloacal samples. There were no significant differences between growth scores at baseline and after storage at -80°C for 40 days for any of the bacteria examined after 48 and 72 hr of incubation, with the exception of P. anaerobius. For P. anaerobius, there was a significant reduction (P < 0.001) in the growth score after storage at -80°C for 40 days from that of the baseline; however, the bacteria were still viable. The tested swab transport system may be useful when lengthy storage and transport times necessitate freezing samples prior to culture.

  18. Comparison of noninvasive sample collection procedures for canine leishmaniasis diagnosis by PCR-hybridization

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Sidney de Almeida; Andrade, Antero Silva Ribeiro de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: vidasnino@yahoo.com.br; antero@cdtn.br; Ituassu, Leonardo Trindade; Melo, Maria Norma de [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)]. E-mail: melo@mono.icb.ufmg.br; ltituassu@yahoo.com.br

    2007-07-01

    The dogs are the main reservoir of the visceral leishmaniasis etiological agent Leishmania chagasi and these animals have to be systematically monitored. The aim of present work was to standardize a method for canine leishmaniasis diagnosis using DNA samples obtained by a noninvasive ways. Two kind of samples were compared: conjunctival swab and blood. The samples were analyzed by the Polymerase Chain Reaction (PCR) associated with the hybridization of {sup 32}P labeled DNA probes. An in vitro test was carried out using cotton swabs seeded with L. chagasi parasites at different cell numbers. After that, the PCR and hybridization sensitivity was evaluated in two groups of 23 seropositive dogs. Conjunctival swabs and 1,0 mL of blood were collected from each animal. 90 {mu}L of these blood were spotted onto filter paper and the remaining used to prepare the buffy coat. The DNA purification from cotton swabs was carried out through the phenol-chloroform (group 1) or boiling (group 2). The Wizard kit was used to DNA extraction from buffy coat. The filters were treated according to Dialab protocol. The analysis of the seeded samples showed that the PCR was able to identify until ten parasites while the following hybridization of the PCR products allows the detection of until one parasite. The PCR positivity for the conjunctival swabs were 73.9% and 52.2% respectively to the groups 1 and 2. For buffy coat the positivities were 43.5% and 56.5% respectively. The filters presented the lowest positivity. The hybridization step was not accomplished yet for these samples. (author)

  19. Loop-mediated isothermal amplification assay for rapid detection of Streptococcus agalactiae (group B streptococcus) in vaginal swabs - a proof of concept study.

    Science.gov (United States)

    McKenna, James Patrick; Cox, Ciara; Fairley, Derek John; Burke, Rachael; Shields, Michael D; Watt, Alison; Coyle, Peter Valentine

    2017-03-01

    Neonatal sepsis caused by Streptococcus agalactiae [group B streptococcus (GBS)] is a life-threatening condition, which is preventable if colonized mothers are identified and given antibiotic prophylaxis during labour. Conventional culture is time consuming and unreliable, and many available non-culture diagnostics are too complex to implement routinely at point of care. Loop-mediated isothermal amplification (LAMP) is a method that, enables the rapid and specific detection of target nucleic acid sequences in clinical materials without the requirement for extensive sample preparation. A prototype LAMP assay targeting GBS sip gene is described. The assay was 100 % specific for GBS, with a limit of detection of 14 genome copies per reaction. The clinical utility of the LAMP assay for rapid direct molecular detection of GBS was determined by testing a total of 157 vaginal swabs with minimal sample processing using a rapid lysis solution. Compared to a reference quantitative real-time PCR assay, the direct LAMP protocol had a sensitivity and specificity of 95.4 and 100 %, respectively, with positive and negative predictive values of 100 and 98.3 %, respectively. Positive and negative likelihood ratios were infinity and 0.05, respectively. The direct LAMP method required a mean time of 45 min from the receipt of a swab to generation of a confirmed result, compared to 2 h 30 min for the reference quantitative real-time PCR test. The direct LAMP protocol described is easy to perform, facilitating rapid and accurate detection of GBS in vaginal swabs. This test has a potential for use at point of care.

  20. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  1. Evaluation of hygiene practices in catering premises at large-scale events in the UK: identifying risks for the Olympics 2012.

    Science.gov (United States)

    Willis, C; Elviss, N; Aird, H; Fenelon, D; McLauchlin, J

    2012-08-01

    To investigate hygiene practices of caterers at large events in order to: support the production of guidance on catering at such events; to compare hygiene standards at weekends with other times in the week; and to learn lessons in preparation for the London Olympics in 2012. UK-wide study of caterers at large events, including questionnaires on hygiene procedures and microbiological examination of food, water and environmental samples. In total, 1364 samples of food, water, surface swabs and cloths were collected at 139 events, by local authority sampling officers, and transported to laboratories for microbiological analysis. Eight percent of food samples were of an unsatisfactory quality, and a further 2% contained potentially hazardous levels of Bacillus spp. A significantly higher proportion of unsatisfactory food samples were taken from vendors without adequate food safety procedures in place. Fifty-two percent of water samples, 38% of swabs and 71% of cloths were also unsatisfactory. The majority of samples (57%) were collected on Saturdays, Sundays or bank holidays. Environmental swab results were significantly poorer at weekends compared with other days of the week. This study reinforces the fact that food hygiene is a continuing cause for concern in mobile vendors, and indicates a need for an ongoing programme of training and monitoring of caterers in preparation for the London Olympics. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  2. Inhibition of PCR-based assay for Bordetella pertussis by using calcium alginate fiber and aluminum shaft components of a nasopharyngeal swab.

    Science.gov (United States)

    Wadowsky, R M; Laus, S; Libert, T; States, S J; Ehrlich, G D

    1994-04-01

    A PCR-based assay for Bordetella pertussis was inhibited by using a calcium alginate fiber-tipped swab with an aluminum shaft but not by using a Dacron fiber-tipped swab with a plastic shaft. The calcium alginate fiber component inhibited the assay following storage for less than 1 min in a suspension of 10(3) CFU of B. pertussis per ml, whereas the aluminum shaft component required storage for at least 48 h in order to cause inhibition. We recommend the Dacron swab over the calcium alginate swab for collecting specimens for testing in PCR-based assays.

  3. Development of a multiplex real-time PCR for the simultaneous detection of herpes simplex and varicella zoster viruses in cerebrospinal fluid and lesion swab specimens.

    Science.gov (United States)

    Wong, Anita A; Pabbaraju, Kanti; Wong, Sallene; Tellier, Raymond

    2016-03-01

    Herpes simplex viruses (HSV) and varicella zoster virus (VZV) can have very similar and wide-ranging clinical presentations. Rapid identification is necessary for timely antiviral therapy, especially with infections involving the central nervous system, neonates, and immunocompromised individuals. Detection of HSV-1, HSV-2 and VZV was combined into one real-time PCR reaction utilizing hydrolysis probes. The assay was validated on the LightCycler(®) (Roche) and Applied Biosystems 7500 Real-Time PCR System (Thermo Fisher Scientific Inc.) to detect alphaherpesviruses in cerebral spinal fluid (CSF) and lesion swab specimens, respectively. Validation data on blood and tissue samples are also presented. The multiplex assay showed excellent sensitivity, specificity and reproducibility when compared to two singleplex real-time PCR assays for CSF samples and direct fluorescent antigen/culture for lesion swab samples. Implementation of the multiplex assay has facilitated improved sensitivity and accuracy as well as reduced turn-around-times and costs. The results from a large data set of 16,622 prospective samples tested between August 16, 2012 to February 1, 2014 at the Provincial Laboratory for Public Health (Alberta, Canada) are presented here. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Evaluation of Petrifilm Lactic Acid Bacteria Plates for Counting Lactic Acid Bacteria in Food.

    Science.gov (United States)

    Kanagawa, Satomi; Ohshima, Chihiro; Takahashi, Hajime; Burenqiqige; Kikuchi, Misato; Sato, Fumina; Nakamura, Ayaka; Mohamed, Shimaa M; Kuda, Takashi; Kimura, Bon

    2018-06-01

    Although lactic acid bacteria (LAB) are used widely as starter cultures in the production of fermented foods, they are also responsible for food decay and deterioration. The undesirable growth of LAB in food causes spoilage, discoloration, and slime formation. Because of these adverse effects, food companies test for the presence of LAB in production areas and processed foods and consistently monitor the behavior of these bacteria. The 3M Petrifilm LAB Count Plates have recently been launched as a time-saving and simple-to-use plate designed for detecting and quantifying LAB. This study compares the abilities of Petrifilm LAB Count Plates and the de Man Rogosa Sharpe (MRS) agar medium to determine the LAB count in a variety of foods and swab samples collected from a food production area. Bacterial strains isolated from Petrifilm LAB Count Plates were identified by 16S rDNA sequence analysis to confirm the specificity of these plates for LAB. The results showed no significant difference in bacterial counts measured by using Petrifilm LAB Count Plates and MRS medium. Furthermore, all colonies growing on Petrifilm LAB Count Plates were confirmed to be LAB, while yeast colonies also formed in MRS medium. Petrifilm LAB Count Plates eliminated the plate preparation and plate inoculation steps, and the cultures could be started as soon as a diluted food sample was available. Food companies are required to establish quality controls and perform tests to check the quality of food products; the use of Petrifilm LAB Count Plates can simplify this testing process for food companies.

  5. Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.

    Science.gov (United States)

    Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil

    2018-01-01

    An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.

  6. Frequency and Antimicrobial Susceptibility Pattern of Acinetobacter Species Isolated from Pus and Pus Swab Specimens

    International Nuclear Information System (INIS)

    Fayyaz, M.; Akbar, N.; Khan, I. U.; Hussain, A.; Ali, S.; Mirza, I. A.

    2015-01-01

    Objective: To evaluate the frequency and antimicrobial susceptibility pattern of Acinetobacter species isolated from pus and pus swab specimens at a tertiary care setting. Study Design: Cross-sectional observational study. Place and Duration of Study: Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from July 2008 to July 2012. Methodology: Data regarding positive culture and antimicrobial sensitivity pattern was retrieved from the pus and pus swab culture records of the Microbiology Department, AFIP, Rawalpindi. Only those pus and pus swab specimens which yielded the growth of Acinetobacter species were included in the study. Results:Out of 2781, 1848 were of pure pus while 933 were pus swab specimens. Out of 2538 culture positive isolates, 276 (10.9 percentage) were identified as Acinetobacterspecies. Among 276 Acinetobacter species, 245 (88.8 percentage) were Acinetobacter baumannii and 31 (11.2 percentage) were Acinetobacter johnsonii. Male/female ratio of the affected patients was 5.6:1. Doxycycline was the most sensitive antibiotic to which 45 percentage of the tested isolates were sensitive. Sensitivity to all other antimicrobials was 15 percentage or less. Conclusion: About 11 percentage of soft tissue and wound infections are caused by Acinetobacter species in our set up particularly in male. Doxycycline was the most sensitive antibiotic. Sensitivity to all other antimicrobials was 15 percentage or less. In vitro sensitivity to carbapenems is very low. (author)

  7. Screening for methicillin-resistant Staphylococcus aureus in clinical swabs using a high-throughput real-time PCR-based method

    DEFF Research Database (Denmark)

    Ornskov, D; Kolmos, B; Bendix Horn, P

    2008-01-01

    2005, all patients and healthcare personnel have been screened for MRSA colonisation, involving analysis of 300-400 samples daily. To deal with this number of samples, a PCR-based method customised for high-throughput analysis and a system for fast reporting of MRSA carrier status were developed. Swab...... samples were incubated overnight in a selective tryptone soya broth and were analysed by PCR the following day. Using this strategy, non-colonised individuals were identified within 24 h, while MRSA-positive samples were analysed further by traditional microbiological methods to determine the resistance...... pattern. This is a cost-effective approach, as the greatest expense in hospitals involves the isolation of patients of unknown MRSA status. The method was evaluated by testing 2194 clinical samples, with a sensitivity and specificity of 100% and 94%, respectively. The analytical sensitivity was 97...

  8. Price promotions for food and beverage products in a nationwide sample of food stores.

    Science.gov (United States)

    Powell, Lisa M; Kumanyika, Shiriki K; Isgor, Zeynep; Rimkus, Leah; Zenk, Shannon N; Chaloupka, Frank J

    2016-05-01

    Food and beverage price promotions may be potential targets for public health initiatives but have not been well documented. We assessed prevalence and patterns of price promotions for food and beverage products in a nationwide sample of food stores by store type, product package size, and product healthfulness. We also assessed associations of price promotions with community characteristics and product prices. In-store data collected in 2010-2012 from 8959 food stores in 468 communities spanning 46 U.S. states were used. Differences in the prevalence of price promotions were tested across stores types, product varieties, and product package sizes. Multivariable regression analyses examined associations of presence of price promotions with community racial/ethnic and socioeconomic characteristics and with product prices. The prevalence of price promotions across all 44 products sampled was, on average, 13.4% in supermarkets (ranging from 9.1% for fresh fruits and vegetables to 18.2% for sugar-sweetened beverages), 4.5% in grocery stores (ranging from 2.5% for milk to 6.6% for breads and cereals), and 2.6% in limited service stores (ranging from 1.2% for fresh fruits and vegetables to 4.1% for breads and cereals). No differences were observed by community characteristics. Less-healthy versus more-healthy product varieties and larger versus smaller product package sizes generally had a higher prevalence of price promotion, particularly in supermarkets. On average, in supermarkets, price promotions were associated with 15.2% lower prices. The observed patterns of price promotions warrant more attention in public health food environment research and intervention. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  10. Food safety assurance systems: Microbiological testing, sampling plans, and microbiological criteria

    NARCIS (Netherlands)

    Zwietering, M.H.; Ross, T.; Gorris, L.G.M.

    2014-01-01

    Microbiological criteria give information about the quality or safety of foods. A key component of a microbiological criterion is the sampling plan. Considering: (1) the generally low level of pathogens that are deemed tolerable in foods, (2) large batch sizes, and (3) potentially substantial

  11. Swab2know: An HIV-Testing Strategy Using Oral Fluid Samples and Online Communication of Test Results for Men Who Have Sex With Men in Belgium.

    Science.gov (United States)

    Platteau, Tom; Fransen, Katrien; Apers, Ludwig; Kenyon, Chris; Albers, Laura; Vermoesen, Tine; Loos, Jasna; Florence, Eric

    2015-09-01

    As HIV remains a public health concern, increased testing among those at risk for HIV acquisition is important. Men who have sex with men (MSM) are the most important group for targeted HIV testing in Europe. Several new strategies have been developed and implemented to increase HIV-testing uptake in this group, among them the Swab2know project. In this project, we aim to assess the acceptability and feasibility of outreach and online HIV testing using oral fluid samples as well as Web-based delivery of test results. Sample collection happened between December 2012 and April 2014 via outreach and online sampling among MSM. Test results were communicated through a secured website. HIV tests were executed in the laboratory. Each reactive sample needed to be confirmed using state-of-the-art confirmation procedures on a blood sample. Close follow-up of participants who did not pick up their results, and those with reactive results, was included in the protocol. Participants were asked to provide feedback on the methodology using a short survey. During 17 months, 1071 tests were conducted on samples collected from 898 men. Over half of the samples (553/1071, 51.63%) were collected during 23 outreach sessions. During an 8-month period, 430 samples out of 1071 (40.15%) were collected from online sampling. Additionally, 88 samples out of 1071 (8.22%) were collected by two partner organizations during face-to-face consultations with MSM and male sex workers. Results of 983 out of 1071 tests (91.78%) had been collected from the website. The pickup rate was higher among participants who ordered their kit online (421/430, 97.9%) compared to those participating during outreach activities (559/641, 87.2%; Ponline participants were more likely to have never been tested before (17.3% vs 10.0%; P=.001) and reported more sexual partners in the 6 months prior to participation in the project (mean 7.18 vs 3.23; Ponline counseling tool), and in studying the cost effectiveness of the

  12. Evaluation of Presto(plus) assay and LightMix kit Trichomonas vaginalis assay for detection of Trichomonas vaginalis in dry vaginal swabs.

    Science.gov (United States)

    de Waaij, Dewi J; Ouburg, Sander; Dubbink, Jan Henk; Peters, Remco P H; Morré, Servaas A

    2016-08-01

    This is an evaluation study of the Presto(plus) Assay for T. vaginalis by comparing to the TIB MOLBIOL LightMix Kit Trichomonas vaginalis Assay using 615 dry collected vaginal and rectal swabs. Discordant samples were analyzed by the Qiagen® Microbial DNA qPCR for TV Assay. Both assays showed comparable performances (McNemar p>0.05). Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Mumps vaccine virus genome is present in throat swabs obtained from uncomplicated healthy recipients.

    Science.gov (United States)

    Nagai, T; Nakayama, T

    2001-01-08

    Seven children were followed for up to 42 days post-vaccination with live mumps vaccine and 37 throat swabs were obtained serially. Viral genomic RNA was detected by reverse transcription-polymerase chain reaction (RT-PCR) in the phosphoprotein (P) and hemagglutinin-neuraminidase (HN) regions. Virus isolation was also attempted. Genomic differentiation of detected mumps virus genome was performed by sequence analysis and/or restriction fragment length polymorphism (RFLP). No adverse reaction was observed in these children. Although mumps virus was not isolated from any of the samples, viral RNA was detected in four samples from three vaccine recipients, 18, 18 and 26, and 7 days after vaccination, respectively. Detected viral RNA was identified as the vaccine strain. Our data suggests that vaccine virus inoculated replicates in the parotid glands but the incidence of virus transmission from recipients to other susceptible subjects should be low.

  14. Rapid Detection of Salmonella in Food and Beverage Samples by Polymerase Chain Reaction

    Directory of Open Access Journals (Sweden)

    Radji, M.

    2010-01-01

    Full Text Available Polymerase chain reaction (PCR assay had been used to detect Salmonella in food and beverage samples using suitable primers which are based on specific invA gene of Salmonella. Twenty nine samples were collected from street food counters and some canteens in Margonda Street, Depok, West Java, Indonesia. It was found that five of twenty nine samples were detected to contain Salmonella and showed the presence of the amplified product of the size 244 bp. The method of PCR demonstrated the specificity of invA primers for detection of Salmonella as confirmed by biochemical and serological assay. The results of this study revealed that PCR was a rapid and useful tool for detection of Salmonella in food and beverage samples.

  15. Comparison of culture versus quantitative real-time polymerase chain reaction for the detection of Taylorella equigenitalis in field samples from naturally infected horses in Canada and Germany.

    Science.gov (United States)

    Nadin-Davis, Susan; Knowles, Margaret K; Burke, Teresa; Böse, Reinhard; Devenish, John

    2015-07-01

    A quantitative real-time polymerase chain reaction method (qPCR) was developed and tested for the detection of Taylorella equigenitalis. It was shown to have an analytical sensitivity of 5 colony-forming units (CFU) of T. equigenitalis when applied to the testing of culture swabs that mimicked field samples, and a high analytical specificity in not reacting to 8 other commensal bacterial species associated with horses. As designed, it could also differentiate specifically between T. equigenitalis and T. asinigenitalis. The qPCR was compared to standard culture in a study that included 45 swab samples from 6 horses (1 stallion, 5 mares) naturally infected with T. equigenitalis in Canada, 39 swab samples from 5 naturally infected stallions in Germany, and 311 swab samples from 87 culture negative horses in Canada. When the comparison was conducted on an individual sample swab basis, the qPCR had a statistical sensitivity and specificity of 100% and 96.4%, respectively, and 100% and 99.1% when the comparison was conducted on a sample set basis. A comparison was also made on 203 sample swabs from the 5 German stallions taken over a span of 4 to 9 mo following antibiotic treatment. The qPCR was found to be highly sensitive and at least as good as culture in detecting the presence of T. equigenitalis in post-treatment samples. The work demonstrates that the qPCR assay described here can potentially be used to detect the presence of T. equigenitalis directly from submitted sample swabs taken from infected horses and also for determining T. equigenitalis freedom following treatment.

  16. An evaluation of clinical performance of FTA cards for HPV 16/18 detection using cobas 4800 HPV Test compared to dry swab and liquid medium.

    Science.gov (United States)

    Dong, Li; Lin, Chunqing; Li, Li; Wang, Margaret; Cui, Jianfeng; Feng, Ruimei; Liu, Bin; Wu, Zeni; Lian, Jia; Liao, Guangdong; Chen, Wen; Qiao, Youlin

    2017-09-01

    Effective dry storage and transport media as an alternative to conventional liquid-based medium would facilitate the accessibility of women in the low-resource settings to human papillomavirus (HPV)- based cervical cancer screening. To evaluate analytical and clinical performance of indicating FTA™ Elute Cartridge (FTA card) for the detection of HPV16/18 and cervical precancerous lesions and cancer compared to dry swab and liquid medium. Ninety patients with abnormal cytology and/or HPV infection were included for analysis. Three specimens of cervical exfoliated cells from each woman were randomly collected by FTA card, dry swab or liquid-based medium prior to colposcopy examination. The subsequent HPV DNA tests were performed on cobas 4800 HPV platform. High-risk HPV (hrHPV) positivity rate was 63.3%, 62.2% and 65.6% for samples collected by FTA card, dry swab and liquid medium, respectively. The overall agreements and kappa values for the detection of hrHPV, HPV 16 and HPV 18 between FTA card and liquid-based medium were 88.9% (κ=0.76), 97.8% (κ=0.94) and 100% (κ=1.0),respectively; between FTA card and dry swab were 92.1% (κ=0.83), 94.5% (κ=0.87) and 100% (κ=1.0), respectively. The performances of hrHPV tested by FTA card, dry swab, and liquid-based medium for detecting CIN2+ were comparable in terms of the sensitivity and specificity. The specificity of detection of CIN2+ by HPV16/18 increased by approximately 40% compared to hrHPV for any medium albeit at cost of a moderate loss of sensitivity. Dry medium might offer an alternative to conventional liquid-based medium in the HPV-based cervical cancer screening program especially in low-resource settings but still needs further evaluation. Copyright © 2017. Published by Elsevier B.V.

  17. Isolation of lymphotropic baboon herpesvirus (HVP) from oral swabs of hamadryas baboons of the Sukhumi monkey colony.

    Science.gov (United States)

    Agrba, V Z; Lapin, B A; Timanovskaya, V V; Dzhachvliany, M C; Kokosha, L V; Chuvirov, G N; Djatchenko, A G

    1980-01-01

    Ways of lymphotropic baboon herpesvirus (HVP) secretion and its excretion into the environment were investigated. Oral swabs and feces from the Sukhumi main stock hamadryas baboons characterized by a high risk for malignant lymphoma and the baboon stock living in isolation in the forest were used as materials for the investigations. Macaque groups of the Sukhumi stock were used as controls. It could be shown that the HVP was resistent in the oral cavity of the main stock baboons and was isolated from oral swabs of these animals both from those with malignant lymphoma and clinically healthy individuals. No virus was isolated from feces of these animals. The virus could not be isolated from oral swabs of the isolated baboon stock and macaques.

  18. A Real-Time PCR Detection of Genus Salmonella in Meat and Milk Samples

    Directory of Open Access Journals (Sweden)

    Jaroslav Pochop

    2013-05-01

    Full Text Available The aim of this study was follow the contamination of ready to eat milk and meat products with Salmonella spp. by using the Step One real-time PCR. Classical microbiological methods for detection of food-borne bacteria involve the use of pre-enrichment and/or specific enrichment, followed by the isolation of the bacteria in solid media and a final confirmation by biochemical and/or serological tests. We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and SensiFAST SYBR Hi-ROX Kit for the real-time PCR performance. In the investigated samples without incubation we could detect strain of Salmonella sp. in five out of twenty three samples (swabs. This Step One real-time PCR assay is extremely useful for any laboratory in possession of a real-time PCR. It is a fast, reproducible, simple, specific and sensitive way to detect nucleic acids, which could be used in clinical diagnostic tests in the future. Our results indicated that the Step One real-time PCR assay developed in this study could sensitively detect Salmonella spp. in ready to eat food.

  19. Staphylococcus aureus food poisoning among Bulawayo City Council employees, Zimbabwe, 2014.

    Science.gov (United States)

    Gumbo, Amen; Bangure, Donewell; Gombe, Notion T; Mungati, More; Tshimanga, Mufuta; Hwalima, Zanele; Dube, Ignatious

    2015-09-28

    Bulawayo City Council held an Integrated Result Based Management workshop among 86 employees from August 18-22, 2014 at Ikhwezi Training Centre in Bulawayo City. On August 21, 2014, a report of diarrhoea among Council employees attending the workshop was received. We investigated the outbreak to determine the risk factors associated with diarrhoea at Ikhwezi Training Centre, Bulawayo City. A retrospective cohort study was conducted where 74 Council employees were interviewed on food consumed and presenting signs and symptoms. Stool specimens and hand swabs were collected for culture. Water samples were collected for bacteriological analysis. Food samples were not available. Data were analysed using Epi Info™ to generate frequencies, means, proportions, risk ratios, and attributable risk. Of the 74 employees interviewed 34 (45.9%) were males and 40 (54%) were females. The response rate was 94%. The common signs and symptoms included abdominal cramps (88.7%), and watery diarrhoea (86.8%). The overall attack rate was 71.6%. Eating stewed chicken (RR = 2.52, 95% CI 1.30-4.89) served at hour 13:00 during lunch on August 20, 2014 at Ikhwezi Training Centre was the only significant risk factor associated with food poisoning. Drinking purified bottled water [RR = 0.67, 95% CI (0.57-0.79)] was found to be protective. Staphylococcus aureus was isolated from the hands and nails of food handlers. The outbreak was due to food poisoning and was most likely caused by the Staphylococcus aureus formed toxins. Stewed chicken served during lunch on August 20, 2014 was the possible source of infection. Contamination might have occurred during food handling and preparation. Training of food handlers in basic food hygiene and safety is recommended.

  20. Characterization of polycyclic aromatic hydrocarbons (PAH's) present in sampled cooked food

    International Nuclear Information System (INIS)

    Palm Naa-Dedei, L.M.

    2010-07-01

    The study was conducted to determine the levels of Polycyclic Aromatic Hydrocarbons in the following traditionally prepared food: smoked and grilled Scomba japonicus, grilled meat (khebab) and bread sampled from some Ghanaian markets. By way of preparation of traditional food, some food comes into direct contact with smoke or extremely high temperature which are potential sources of Polycyclic Aromatic Hydrocarbon generation. Levels of 20 individual Polycyclic Aromatic Hydrocarbons including acenaphthene, acenaphtyelene, anthanthrene, anthracene, benz(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(e)pyrene, benzo(ghi)perylene, benzo(j)fluoranthene, benzo(k)fluoranthene, chrysene, cyclopenta(cd)pyrene, dibenzo(ah)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenanthrene and pyrene were determined in 11 smoked and 5 grilled fish, 4 grilled pieces of meat and 3 loaves of baked bread using gas chromatographic techniques with flame ionization detector. Benzo(a)pyrene, which is one of the few PAH for which a legal limit exists in different types of food matrices and other high molecular weight PAHs suspected to be carcinogenic have been detected in high concentrations in most samples. Bread samples gave mean polycyclic aromatic hydrocarbon concentrations of up to 20.39 μg/kg while khebab samples gave mean polycyclicaromatic hydrocarbon concentrations of up to 67.61 μg/kg. There was positive correlation of 0.987 between levels of polycyclic aromatic hydrocarbon concentrations in khebab samples from locations Osu and Atomic down. There was a positive correlation in the concentrations of the high molecular weight PAHs in all smoked fishes from four locations with values between 0.954 and 0.999 for the correlation between any two groups. The polycyclic aromatic hydrocarbon concentration determined in smoked fish samples deceased in terms of location according to the order Winneba > Madina > Chorkor > Ada.

  1. Impact of enzymatic digestion on bacterial community composition in CF airway samples.

    Science.gov (United States)

    Williamson, Kayla M; Wagner, Brandie D; Robertson, Charles E; Johnson, Emily J; Zemanick, Edith T; Harris, J Kirk

    2017-01-01

    Previous studies have demonstrated the importance of DNA extraction methods for molecular detection of Staphylococcus, an important bacterial group in cystic fibrosis (CF). We sought to evaluate the effect of enzymatic digestion (EnzD) prior to DNA extraction on bacterial communities identified in sputum and oropharyngeal swab (OP) samples from patients with CF. DNA from 81 samples (39 sputum and 42 OP) collected from 63 patients with CF was extracted in duplicate with and without EnzD. Bacterial communities were determined by rRNA gene sequencing, and measures of alpha and beta diversity were calculated. Principal Coordinate Analysis (PCoA) was used to assess differences at the community level and Wilcoxon Signed Rank tests were used to compare relative abundance (RA) of individual genera for paired samples with and without EnzD. Shannon Diversity Index (alpha-diversity) decreased in sputum and OP samples with the use of EnzD. Larger shifts in community composition were observed for OP samples (beta-diversity, measured by Morisita-Horn), whereas less change in communities was observed for sputum samples. The use of EnzD with OP swabs resulted in significant increase in RA for the genera Gemella ( p  microbial community composition. We show that the application of EnzD to CF airway samples, particularly OP swabs, results in differences in microbial communities detected by sequencing. Use of EnzD can result in large changes in bacterial community composition, and is particularly useful for detection of Staphylococcus in CF OP samples. The enhanced identification of Staphylococcus aureus is a strong indication to utilize EnzD in studies that use OP swabs to monitor CF airway communities.

  2. Trace elements detection in whole food samples by Neutron Activation Analysis, k0-method

    International Nuclear Information System (INIS)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia; Salles, Paula Maria Borges de

    2017-01-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k 0 -method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k 0 - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  3. [An epidemiological investigation on a food-born outbreak of noroviru caused by Sydney 2012 G II.4 strain].

    Science.gov (United States)

    Cai, Wen-Feng; Xie, Hua-Ping; Liu, Yu-Fei; Yuan, Jun; Xiao, Xin-Cai; Ding, Peng; Chen, Chun; Zhang, Du; Chen, Jian-Dong; Ma, Xiao-Wei; Geng, Jin-Mei; Lin, Dong-Ming; Lian, Gui-Xiong; Yang, Zhi-Cong

    2013-08-01

    To identify the source of infection, route of transmission and risk factors related to a cluster of acute gastroenteritis cases in a university of Guangzhou. Cases were identified according to the definition. Descriptive epidemiological approaches and case-control study designs were employed in the analysis. All the samples were tested for norovirus by RT-PCR. Positive samples were subjected to both nucleotide sequence and homology analysis. A total of 141 cases related to norovirus gastroenteritis were identified in January 8 to 21, 2013, with the attack rate as 8.5 per thousand (141/16,600). The peak in morbidity was seen on January 8 to 9. No clustering was found in different classes or dormitories. Results from the case-control study revealed that early cases were infected in Restaurant A (OR = 3.46, 95% CI: 1.07-11.16) and the cold shredded chicken set meal (OR = 17.82, 95% CI: 4.46-78.17) served at lunch (OR = 4.34, 95% CI: 1.18 -17.37) on January 7 was under suspicion. A total of 266 samples, including rectal swabs from the patients and kitchen wokers, leftover food and environmental swabs, were collected. Twenty-one samples (collected from 17 persons) were positive for norovirus by RT-PCR. About 29.6% (8/27) of the kitchen workers in the Restaurant A were tested positive for the virus. The pathogen was identified as the new norovirus genotype II.4 variant, termed Sydney 2012. The virus strains isolated from the patients among student and staff and the kitchen workers were 100% identical in their nucleotide sequence. This was the first reported acute gastroenteritis outbreak caused by the new norovirus genotype II.4 variant, Sydney 2012, which showed that the food was contaminated by the asymptomatic kitchen workers who carried the virus.

  4. MICROBIOLOGICAL EVALUATION OF ANTIBIOTIC RESIDUES IN MEAT, MILK AND EGGS

    Directory of Open Access Journals (Sweden)

    Abdul Jabbar

    2013-04-01

    Full Text Available Microbiological tests are widely used to detect antibiotic residues in the meat, milk and eggs for better care of the quality and health safety. In the present study microbiological inhibition test i.e. Swab Test on Animal Food (STAF was developed indigenously for screening of animal foods for presence of antibiotic residues. In this test local isolated culture of Bacillus subtilis was used as a test microorganism due to its high sensitivity to detect a wide range of antibiotics commonly used in animal disorders. The concentration of spore suspension of Bacillus subtilis JS2004 used in the formation of STAF plate was optimized at 2x107 spores/ ml. At this concentration, inhibition zone around Neomycin control disc was 10-16 mm. Nutrient agar was used as a medium in spore suspension and 0.4% dextrose was added as a constituent of medium. Zones of inhibition around swab samples and Neomycin control disc were observed and the diameter was measured. All swab samples showing a minimum of 2 mm wide inhibition zone around them were considered as positive for presence of antibiotic residues. The swab samples showing no zone of inhibition or a zone measuring less than 2 mm were considered as negative. Results of application of STAF test was on animal food samples revealed the high incidence of antibiotic residues.

  5. Bacterial assessment of food handlers in Sari City, Mazandaran Province, north of Iran

    Directory of Open Access Journals (Sweden)

    Mohtaram Nasrolahei

    2017-03-01

    Full Text Available Food handlers with poor personal hygiene could be potential sources of infection due to pathogenic bacteria. This study was designed to determine the prevalence of bacterial infestation among the food handlers attending the public health center laboratory in Sari, northern Iran for annual check-up.This study was performed from September 2013 to August 2014. Stool samples, fingernail specimens of both hands and nasal swabs were collected from 220 male and female food handlers of different jobs, aged between 17–65 years. The samples were cultured on bacteriological culture media and bacterial species were identified following standard procedures. A structured questionnaire was used to record sociodemographic and behavioral data analysis of the food handlers.Of the total 220 subjects examined, 62.2% showed positive culture for different bacterial species from their fingernail contents, 65.4% were found to be harboring Staphylococcus aureus in their nostrils and 0.9% tested positive for Shigella boydii from stool samples. Staphylococcus aureus was the predominant bacteria isolated from fingernail specimens (46%, followed by Escherichia coli (29.2%, Coliforms (18.2% and Pseudomonas aeruginosa (6.6%. This study showed a statistically significant difference in the rate of bacterial infestation between different occupational categories (p = 0.04. Butchers showed the highest prevalence of bacteria (86.6% in their fingernail contents, followed by fast food workers (76.5%, bakers (73.5%, chicken store workers (73%, school cafeterias staff (53.3%, restaurant workers (46.9% and fruit/vegetables sellers (42.5%. The highest rate of nasal carrier for Staphylococcus aureus was observed among chicken store workers 14/17(20.8%.These findings indicate the need for intensive training/retraining and health education of all food service employees and strengthening the existing screening methods to control the problem of bacterial infestation in food handlers

  6. A Study of Isolates from Female Genital Swab Specimens in a ...

    African Journals Online (AJOL)

    Infective vaginal discharge, when left untreated, is a possible risk of acquisition of HIV/AIDS as well as other complications. To detect some common microbial agents of vaginal discharge in order to improve the current syndromic management of abnormal vaginal discharge. A prospective study of female genital swabs ...

  7. A miniaturized and integrated gel post platform for multiparameter PCR detection of herpes simplex viruses from raw genital swabs.

    Science.gov (United States)

    Manage, Dammika P; Lauzon, Jana; Atrazhev, Alexey; Morrissey, Yuen C; Edwards, Ann L; Stickel, Alexander J; Crabtree, H John; Pabbaraju, Kanti; Zahariadis, George; Yanow, Stephanie K; Pilarski, Linda M

    2012-05-07

    Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2-14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1-2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 μL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.

  8. Ultra-processed food purchases in Norway: a quantitative study on a representative sample of food retailers.

    Science.gov (United States)

    Solberg, Siri Løvsjø; Terragni, Laura; Granheim, Sabrina Ionata

    2016-08-01

    To identify the use of ultra-processed foods - vectors of salt, sugar and fats - in the Norwegian diet through an assessment of food sales. Sales data from a representative sample of food retailers in Norway, collected in September 2005 (n 150) and September 2013 (n 170), were analysed. Data consisted of barcode scans of individual food item purchases, reporting type of food, price, geographical region and retail concept. Foods were categorized as minimally processed, culinary ingredients, processed products and ultra-processed. Indicators were share of purchases and share of expenditure on food categories. Six geographical regions in Norway. The barcode data included 296 121 observations in 2005 and 501 938 observations in 2013. Ultra-processed products represented 58·8 % of purchases and 48·8 % of expenditure in 2013. Minimally processed foods accounted for 17·2 % of purchases and 33·0 % of expenditure. Every third purchase was a sweet ultra-processed product. Food sales changed marginally in favour of minimally processed foods and in disfavour of processed products between 2005 and 2013 (χ 2 (3)=203 195, Pprocessed products accounted for the majority of food sales in Norway, indicating a high consumption of such products. This could be contributing to rising rates of overweight, obesity and non-communicable diseases in the country, as findings from other countries indicate. Policy measures should aim at decreasing consumption of ultra-processed products and facilitating access (including economic) to minimally processed foods.

  9. Food Hardship and Obesity in a Sample of Low-Income Immigrants.

    Science.gov (United States)

    Caspi, Caitlin E; Tucker-Seeley, Reginald D; Adamkiewicz, Gary; Roberto, Christina A; Stoddard, Anne M; Sorensen, Glorian C

    2017-02-01

    Very little work has examined the relationship between food hardship (having inconsistent financial resources to buy food) and obesity among immigrant groups. A cross-sectional study was conducted in a low-income, multi-racial/ethnic adult sample in greater Boston, MA (n = 828). Modified Poisson regression models estimated the association between food hardship obesity (BMI ≥ 30) among adults reporting food hardship; interactions were tested by place of birth. Body mass index (BMI) was based on anthropometric height and weight. In adjusted models, those experiencing food hardship were more likely to be obese (RR 1.17, CI 1.07, 1.29) than those not experiencing food hardship. Participants from Haiti reporting food hardship were more likely to be obese than those not reporting hardship (RR 1.58, CI 1.23, 2.04); this was not the case among other groups (US born, Puerto Rican, Latin American, Other). The relationship between food hardship and weight may vary among immigrant subgroups.

  10. Review Paper of Radionuclide Monitoring in Food Sample

    International Nuclear Information System (INIS)

    Noor Fadzilah Yusof; Abdul Kadir Ishak; Wo, Y.M.; Nurrul Assyikeen Mohd Jaffary

    2011-01-01

    The uncontrolled release of radionuclides into the atmospheric and aquatic environments may occur as the result of a nuclear or radiological accident. Monitoring of the accidental release at its source and especially direct monitoring of the environmental contamination with radionuclides is necessary for assessment and application of public protective actions and longer term countermeasures as well as emergency workers' protection. In areas historically contaminated with long lived radionuclides monitoring it is essential to protect the public and substantiation of any radiological incidents. Also, dietary pathways can be contaminated with radioactive materials resulting from natural occurrence or man-made applications especially during routine operation, accidents and migration of radionuclides from radioactive waste disposal repositories into the biosphere. Therefore, efforts should be made to determine the presence of radionuclides in a potentially high radiation area especially in operational nuclear facilities. This paper will review the strategies for food monitoring that has been adapted in most countries to obtain baseline data for future reference. Also, this study is discussing the type of food selection commonly collected as sample for radionuclide analysis in different countries over the years. Sampling procedure and analysis also included in this review for better understanding of the analysis. Stake holders' involvement is considered as an important asset in the establishment of monitoring strategies. As a conclusion, future plans for food monitoring programme in Malaysia are recommended as a preparation to embark on the Nuclear Power Plant programme. (author)

  11. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    Science.gov (United States)

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  12. A quantitative swab is a good non-invasive alternative to a quantitative biopsy for quantifying bacterial load in wounds healing by second intention in horses.

    Science.gov (United States)

    Van Hecke, L L; Hermans, K; Haspeslagh, M; Chiers, K; Pint, E; Boyen, F; Martens, A M

    2017-07-01

    The aim of this study was to evaluate different techniques for diagnosing wound infection in wounds healing by second intention in horses and to assess the effect of a vortex and sonication protocol on quantitative bacteriology in specimens with a histologically confirmed biofilm. In 50 wounds healing by second intention, a clinical assessment, a quantitative swab, a semi-quantitative swab, and a swab for cytology were compared to a quantitative tissue biopsy (reference standard). Part of the biopsy specimen was examined histologically for evidence of a biofilm. There was a significant, high correlation (Pquantitative swabs and the quantitative biopsies. The semi-quantitative swabs showed a significant, moderate correlation with the quantitative biopsies (Pquantitative swab is an acceptable non-invasive alternative to a quantitative biopsy for quantifying bacterial load in equine wounds healing by second intention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. o-TOF ICPMS analysis of environmental, food and biological samples

    International Nuclear Information System (INIS)

    Krejcova, A.; Cernohorsky, T.; Ludvikova, I.; Pouzar, M.; Capova, L.

    2009-01-01

    Full text: o-TOF ICPMS was used for inorganic analysis of environmental, food and biological samples. The method validity was proved by analysis of spiked samples, reference materials, by determination without/with internal standards and the standard addition technique. The technique was shown to be powerful, and reliable for analysis of the samples mentioned, and high sample throughput enables environmental or biological screening studies. Independent of the number of elements analyzed, complete analysis and whole mass spectra are gained from a small sample amount in a very short time. (author)

  14. Evaluation of the reliability of Levine method of wound swab for ...

    African Journals Online (AJOL)

    The aim of this paper is to evaluate the reliability of Levine swab in accurate identification of microorganisms present in a wound and identify the necessity for further studies in this regard. Methods: A semi structured questionnaire was administered and physical examination was performed on patients with chronic wounds ...

  15. Comparison of sample types and diagnostic methods for in vivo detection of Mycoplasma hyopneumoniae during early stages of infection.

    Science.gov (United States)

    Pieters, Maria; Daniels, Jason; Rovira, Albert

    2017-05-01

    Detection of Mycoplasma hyopneumoniae in live pigs during the early stages of infection is critical for timely implementation of control measures, but is technically challenging. This study compared the sensitivity of various sample types and diagnostic methods for detection of M. hyopneumoniae during the first 28days after experimental exposure. Twenty-one 8-week old pigs were intra-tracheally inoculated on day 0 with M. hyopneumoniae strain 232. Two age matched pigs were mock inoculated and maintained as negative controls. On post-inoculation days 0, 2, 5, 9, 14, 21 and 28, nasal swabs, laryngeal swabs, tracheobronchial lavage fluid, and blood samples were obtained from each pig and oral fluid samples were obtained from each room in which pigs were housed. Serum samples were assayed by ELISA for IgM and IgG M. hyopneumoniae antibodies and C-reactive protein. All other samples were tested for M. hyopneumoniae DNA by species-specific real-time PCR. Serum antibodies (IgG) to M. hyopneumoniae were detected in challenge-inoculated pigs on days 21 and 28. M. hyopneumoniae DNA was detected in samples from experimentally inoculated pigs beginning at 5days post-inoculation. Laryngeal swabs at all samplings beginning on day 5 showed the highest sensitivity for M. hyopneumoniae DNA Detection, while oral fluids showed the lowest sensitivity. Although laryngeal swabs are not considered the typical M. hyopneumoniae diagnostic sample, under the conditions of this study laryngeal swabs tested by PCR proved to be a practical and reliable diagnostic sample for M. hyopneumoniae detection in vivo during early-stage infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Use of FTA sampling cards for molecular detection of avian influenza virus in wild birds.

    Science.gov (United States)

    Keeler, Shamus P; Ferro, Pamela J; Brown, Justin D; Fang, Xingwang; El-Attrache, John; Poulson, Rebecca; Jackwood, Mark W; Stallknecht, David E

    2012-03-01

    Current avian influenza (AI) virus surveillance programs involving wild birds rely on sample collection methods that require refrigeration or low temperature freezing to maintain sample integrity for virus isolation and/or reverse-transcriptase (RT) PCR. Maintaining the cold chain is critical for the success of these diagnostic assays but is not always possible under field conditions. The aim of this study was to test the utility of Finders Technology Associates (FTA) cards for reliable detection of AI virus from cloacal and oropharyngeal swabs of wild birds. The minimum detectable titer was determined, and the effect of room temperature storage was evaluated experimentally using multiple egg-propagated stock viruses (n = 6). Using real time RT-PCR, we compared results from paired cloacal swab and samples collected on FTA cards from both experimentally infected mallards (Anasplatyrhynchos) and hunter-harvested waterfowl sampled along the Texas Gulf Coast. Based on the laboratory trials, the average minimal detectable viral titer was determined to be 1 x 10(4.7) median embryo infectious dose (EID50)/ml (range: 1 x 10(4.3) to 1 x 10(5.4) EID50/ml), and viral RNA was consistently detectable on the FTA cards for a minimum of 20 days and up to 30 days for most subtypes at room temperature (23 C) storage. Real-time RT-PCR of samples collected using the FTA cards showed fair to good agreement in live birds when compared with both real-time RT-PCR and virus isolation of swabs. AI virus detection rates in samples from several wild bird species were higher when samples were collected using the FTA cards compared with cloacal swabs. These results suggest that FTA cards can be used as an alternative sample collection method when traditional surveillance methods are not possible, especially in avian populations that have historically received limited testing or situations in which field conditions limit the ability to properly store or ship swab samples.

  17. Polymerase chain reaction for detection of Mycobacterium leprae in nasal swab specimens

    NARCIS (Netherlands)

    de Wit, M. Y.; Douglas, J. T.; McFadden, J.; Klatser, P. R.

    1993-01-01

    The polymerase chain reaction based on the selective amplification of a 531-bp fragment of the gene encoding the proline-rich antigen of Mycobacterium leprae was applied to nasal swab specimens from leprosy patients, occupational contacts, and endemic and nonendemic controls. To prevent

  18. Analysis of polonium-210 in food samples

    International Nuclear Information System (INIS)

    Bueno, Luciana; Cunha, Ieda Irma Lamas

    1999-01-01

    This paper presents the polonium levels in food products. The analysis procedure consisted of acid leaching of the samples, solution evaporation, addition of hydrochloric acid, spontaneous deposition of polonium on a silver disk counting by alpha spectroscopy. The method was applied in reference materials and in foodstuffs, resulting in the following values: tea samples 0.4 to 1.7 Bq/unit; fish = 0.17 to 0.40 Bq/Kg, fruits = 0.048 to 0.067 Bq/kg, vegetables = 0.12 to 0.31 Bq/kg, cereal = 0.036 to 0.042 Bq/kg and legumes = 0.024 to 0.51 Bq/kg. The results are very important for public health due to the possible effects to the human organism by the ingestion of contaminated foodstuffs. (author)

  19. [Influence of distinct criteria for selecting patients for swabbing on estimation of the effectiveness of the influenza vaccine].

    Science.gov (United States)

    Martínez-Baz, Iván; Guevara, Marcela; Elía, Fernando; Ezpeleta, Carmen; Fernández Alonso, Mirian; Castilla, Jesús

    2014-01-01

    To estimate the effectiveness of the influenza vaccine under different criteria for selecting patients for swabbing. A case-control study was performed of laboratory-confirmed cases (n=909) and negative controls for influenza (n=732) in the 2010-2011 to 2012-2013 seasons in Navarre (Spain). The adjusted vaccine effectiveness was estimated by including all swabs from patients with influenza-like-illness and selecting only the first two cases per physician and week. The first two patients per physician and week were less frequently vaccinated against influenza (7.9% vs. 12.5%, p=0.021) and less often received confirmation of influenza (53.6% vs. 66.4%, p <0.001) than subsequent patients. These differences decreased after adjustment for covariates. The effectiveness of the influenza vaccine was 49% (95% CI: 23-66%) when all swabs were included and was 55% (95% CI: 27-72%) when we selected the first two swabs per week and physician. The selection of the first two patients per physician and week may bias assessment of the effectiveness of the influenza vaccine, although this bias was small in the seasons analyzed. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  20. Inhibition of PCR-based assay for Bordetella pertussis by using calcium alginate fiber and aluminum shaft components of a nasopharyngeal swab.

    OpenAIRE

    Wadowsky, R M; Laus, S; Libert, T; States, S J; Ehrlich, G D

    1994-01-01

    A PCR-based assay for Bordetella pertussis was inhibited by using a calcium alginate fiber-tipped swab with an aluminum shaft but not by using a Dacron fiber-tipped swab with a plastic shaft. The calcium alginate fiber component inhibited the assay following storage for less than 1 min in a suspension of 10(3) CFU of B. pertussis per ml, whereas the aluminum shaft component required storage for at least 48 h in order to cause inhibition. We recommend the Dacron swab over the calcium alginate ...

  1. Recent trends in sorption-based sample preparation and liquid chromatography techniques for food analysis.

    Science.gov (United States)

    V Soares Maciel, Edvaldo; de Toffoli, Ana Lúcia; Lanças, Fernando Mauro

    2018-04-20

    The accelerated rising of the world's population increased the consumption of food, thus demanding more rigors in the control of residue and contaminants in food-based products marketed for human consumption. In view of the complexity of most food matrices, including fruits, vegetables, different types of meat, beverages, among others, a sample preparation step is important to provide more reliable results when combined with HPLC separations. An adequate sample preparation step before the chromatographic analysis is mandatory in obtaining higher precision and accuracy in order to improve the extraction of the target analytes, one of the priorities in analytical chemistry. The recent discovery of new materials such as ionic liquids, graphene-derived materials, molecularly imprinted polymers, restricted access media, magnetic nanoparticles, and carbonaceous nanomaterials, provided high sensitivity and selectivity results in an extensive variety of applications. These materials, as well as their several possible combinations, have been demonstrated to be highly appropriate for the extraction of different analytes in complex samples such as food products. The main characteristics and application of these new materials in food analysis will be presented and discussed in this paper. Another topic discussed in this review covers the main advantages and limitations of sample preparation microtechniques, as well as their off-line and on-line combination with HPLC for food analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Molecularly imprinted polymers for sample preparation and biosensing in food analysis: Progress and perspectives.

    Science.gov (United States)

    Ashley, Jon; Shahbazi, Mohammad-Ali; Kant, Krishna; Chidambara, Vinayaka Aaydha; Wolff, Anders; Bang, Dang Duong; Sun, Yi

    2017-05-15

    Molecularly imprinted polymers (MIPs) are biomimetics which can selectively bind to analytes of interest. One of the most interesting areas where MIPs have shown the biggest potential is food analysis. MIPs have found use as sorbents in sample preparation attributed to the high selectivity and high loading capacity. MIPs have been intensively employed in classical solid-phase extraction and solid-phase microextraction. More recently, MIPs have been combined with magnetic bead extraction, which greatly simplifies sample handling procedures. Studies have consistently shown that MIPs can effectively minimize complex food matrix effects, and improve recoveries and detection limits. In addition to sample preparation, MIPs have also been viewed as promising alternatives to bio-receptors due to the inherent molecular recognition abilities and the high stability in harsh chemical and physical conditions. MIPs have been utilized as receptors in biosensing platforms such as electrochemical, optical and mass biosensors to detect various analytes in food. In this review, we will discuss the current state-of-the-art of MIP synthesis and applications in the context of food analysis. We will highlight the imprinting methods which are applicable for imprinting food templates, summarize the recent progress in using MIPs for preparing and analysing food samples, and discuss the current limitations in the commercialisation of MIPs technology. Finally, future perspectives will be given. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Association between time perspective and organic food consumption in a large sample of adults.

    Science.gov (United States)

    Bénard, Marc; Baudry, Julia; Méjean, Caroline; Lairon, Denis; Giudici, Kelly Virecoulon; Etilé, Fabrice; Reach, Gérard; Hercberg, Serge; Kesse-Guyot, Emmanuelle; Péneau, Sandrine

    2018-01-05

    Organic food intake has risen in many countries during the past decades. Even though motivations associated with such choice have been studied, psychological traits preceding these motivations have rarely been explored. Consideration of future consequences (CFC) represents the extent to which individuals consider future versus immediate consequences of their current behaviors. Consequently, a future oriented personality may be an important characteristic of organic food consumers. The objective was to analyze the association between CFC and organic food consumption in a large sample of the adult general population. In 2014, a sample of 27,634 participants from the NutriNet-Santé cohort study completed the CFC questionnaire and an Organic-Food Frequency questionnaire. For each food group (17 groups), non-organic food consumers were compared to organic food consumers across quartiles of the CFC using multiple logistic regressions. Moreover, adjusted means of proportions of organic food intakes out of total food intakes were compared between quartiles of the CFC. Analyses were adjusted for socio-demographic, lifestyle and dietary characteristics. Participants with higher CFC were more likely to consume organic food (OR quartile 4 (Q4) vs. Q1 = 1.88, 95% CI: 1.62, 2.20). Overall, future oriented participants were more likely to consume 14 food groups. The strongest associations were observed for starchy refined foods (OR = 1.78, 95% CI: 1.63, 1.94), and fruits and vegetables (OR = 1.74, 95% CI: 1.58, 1.92). The contribution of organic food intake out of total food intake was 33% higher in the Q4 compared to Q1. More precisely, the contribution of organic food consumed was higher in the Q4 for 16 food groups. The highest relative differences between Q4 and Q1 were observed for starchy refined foods (22%) and non-alcoholic beverages (21%). Seafood was the only food group without a significant difference. This study provides information on the personality of

  4. Trace elements detection in whole food samples by Neutron Activation Analysis, k{sub 0}-method

    Energy Technology Data Exchange (ETDEWEB)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia, E-mail: maia.sathler@gmail.com, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Salles, Paula Maria Borges de, E-mail: pauladesalles@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k{sub 0}-method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k{sub 0} - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  5. Consensus of microbiology reporting of ear swab results to primary care clinicians in patients with otitis externa.

    Science.gov (United States)

    Geyer, M; Howell-Jones, R; Cunningham, R; McNulty, C

    2011-01-01

    Otitis externa is a ubiquitous inflammatory disease; although it arises most commonly from an infection, there is no consensus in the UK for the reporting of ear swab culture results. This study aims to review current microbiology laboratory reporting of ear swab specimens to primary care and reach an evidence-based consensus for a reporting policy. Fifty consecutive ear swab reports were reviewed from each of 12 laboratories in the South West region to determine and discuss reporting practice. The Health Protection Agency (HPA) GP Microbiology Laboratory Use Group reviewed the underlying evidence and worked towards a consensus of expert microbiology opinion for laboratory reporting of ear swab results using a modified version of the Delphi technique. A total of 487 reports from primary care were reviewed (54% female; 46% male). Cultures most commonly yielded Pseudomonas species (36%), Staphylococcus species (21%), Streptococcus species (15%) and fungi (11%). Five reporting policies were agreed: Policy 1: Common pathogens such as group A beta-haemolytic streptococci, Streptococcus pneumoniae, Staphylococcus aureus - Always reported by name with antibiotic susceptibilities. Policy 2: Pseudomonas species - Always reported, but antibiotic susceptibilities only reported in severe disease. Policy 3: Aspergillus, Candida, coliforms and Proteus species, as well as non-group A streptococci and anaerobes - Only reported if moderate numbers of colonies and it is the predominant organism present; if appropriate report antibiotic susceptibilities. Policy 4: Coagulase-negative staphylococci, diphtheroids and enterococci - Not reported by name; generic terms used and antibiotic susceptibilities not reported. Policy 5: When antibiotic susceptibilities reported these must include susceptibility to a topical antibiotic. It is suggested that laboratories should consider adopting this evidence-based reporting consensus for ear swab culture results from primary care patients with

  6. Frequency, Antimicrobial Resistance and Genetic Diversity of Klebsiella pneumoniae in Food Samples.

    Directory of Open Access Journals (Sweden)

    Yumei Guo

    Full Text Available This study aimed to assess the frequency of Klebsiella pneumoniae in food samples and to detect antibiotic resistance phenotypes, antimicrobial resistance genes and the molecular subtypes of the recovered isolates. A total of 998 food samples were collected, and 99 (9.9% K. pneumoniae strains were isolated; the frequencies were 8.2% (4/49 in fresh raw seafood, 13.8% (26/188 in fresh raw chicken, 11.4% (34/297 in frozen raw food and 7.5% (35/464 in cooked food samples. Antimicrobial resistance was observed against 16 antimicrobials. The highest resistance rate was observed for ampicillin (92.3%, followed by tetracycline (31.3%, trimethoprim-sulfamethoxazole (18.2%, and chloramphenicol (10.1%. Two K. pneumoniae strains were identified as extended-spectrum β-lactamase (ESBL-one strain had three beta-lactamases genes (blaSHV, blaCTX-M-1, and blaCTX-M-10 and one had only the blaSHV gene. Nineteen multidrug-resistant (MDR strains were detected; the percentage of MDR strains in fresh raw chicken samples was significantly higher than in other sample types (P<0.05. Six of the 18 trimethoprim-sulfamethoxazole-resistant strains carried the folate pathway inhibitor gene (dhfr. Four isolates were screened by PCR for quinolone resistance genes; aac(6'-Ib-cr, qnrB, qnrA and qnrS were detected. In addition, gyrA gene mutations such as T247A (Ser83Ile, C248T (Ser83Phe, and A260C (Asp87Ala and a parC C240T (Ser80Ile mutation were identified. Five isolates were screened for aminoglycosides resistance genes; aacA4, aacC2, and aadA1 were detected. Pulsed-field gel electrophoresis-based subtyping identified 91 different patterns. Our results indicate that food, especially fresh raw chicken, is a reservoir of antimicrobial-resistant K. pneumoniae, and the potential health risks posed by such strains should not be underestimated. Our results demonstrated high prevalence, antibiotic resistance rate and genetic diversity of K. pneumoniae in food in China. Improved

  7. Examining the hemagglutinin subtype diversity among wild duck-origin influenza A viruses using ethanol-fixed cloacal swabs and a novel RT-PCR method.

    Science.gov (United States)

    Wang, Ruixue; Soll, Lindsey; Dugan, Vivien; Runstadler, Jonathan; Happ, George; Slemons, Richard D; Taubenberger, Jeffery K

    2008-05-25

    This study presents an interconnected approach for circumventing two inherent limitations associated with studies defining the natural history of influenza A viruses in wild birds. The first limiting factor is the ability to maintain a cold chain from specimen collection to the laboratory when study sites are in more remote locations. The second limiting factor is the ability to identify all influenza A virus HA subtypes present in an original sample. We report a novel method for molecular subtyping of avian influenza A virus hemagglutinin genes using degenerate primers designed to amplify all known hemagglutinin subtypes. It was shown previously that templates larger than 200 bp were not consistently amplifiable from ethanol-fixed cloacal swabs. For this study, new primer sets were designed within these constraints. This method was used to perform subtyping RT-PCR on 191 influenza RNA-positive ethanol-fixed cloacal swabs obtained from 880 wild ducks in central Alaska in 2005. Seven different co-circulating hemagglutinin subtypes were identified in this study set, including H1, H3, H4, H5, H6, H8, and H12. In addition, 16% of original cloacal samples showed evidence of mixed infection, with samples yielding from two-to-five different hemagglutinin subtypes. This study further demonstrates the complex ecobiology of avian influenza A viruses in wild birds.

  8. Effect of sampling and short isolation methodologies on the recovery of human pathogenic Yersinia enterocolitica from pig tonsils.

    Science.gov (United States)

    Van Damme, Inge; Berkvens, Dirk; De Zutter, Lieven

    2012-07-01

    The objective of this study was to determine the effect of sampling (swab samples compared to destructive samples) on isolation rates of human pathogenic Yersinia enterocolitica from pig tonsils. Moreover, the relative efficiency of different rapid, routinely applicable isolation methods was evaluated. Therefore, swab and destructive samples from tonsils of 120 pigs at slaughter were analyzed in parallel using direct plating and different enrichment methods. Salmonella-Shigella-desoxycholate-calcium chloride (SSDC) agar, cefsulodin-irgasan-novobiocin (CIN) agar, and Yersinia enterocolitica chromogenic medium (YeCM) were used as selective agar media. For enrichment, irgasan-ticarcillin-potassium chlorate (ITC) broth and peptone-sorbitol-bile (PSB) broth were incubated at 25°C for 48 h. Overall, 55 tonsils (45.8%) were positive for Y. enterocolitica bioserotype 4/O:3. Recovery was significantly higher using the destructive method compared to the swabbing method. Direct plating resulted in 47 and 28 Y. enterocolitica-positive destructive and swab samples, respectively. Alkali treatment of PSB and ITC enrichment broths significantly increased recovery of pathogenic Y. enterocolitica from destructive tonsil samples. The performance of YeCM for qualitative and quantitative isolation of pathogenic Y. enterocolitica from pig tonsils was equal to SSDC and CIN. In conclusion, direct plating and ISO 10273: 2003 with minor modifications are suitable and rapid methods for isolation of pathogenic Y. enterocolitica from destructive tonsil samples.

  9. Molecularly imprinted polymers for sample preparation and biosensing in food analysis: Progress and perspectives

    DEFF Research Database (Denmark)

    Ashley, Jon; Shahbazi, Mohammad-Ali; Kant, Krishna

    2017-01-01

    Molecularly imprinted polymers (MIPs) are biomimetics which can selectively bind to analytes of interest. One of the most interesting areas where MIPs have shown the biggest potential is food analysis. MIPs have found use as sorbents in sample preparation attributed to the high selectivity and high...... the imprinting methods which are applicable for imprinting food templates, summarize the recent progress in using MIPs for preparing and analysing food samples, and discuss the current limitations in the commercialisation of MIPs technology. Finally, future perspectives will be given....

  10. Antibiotic Resistance Among Staphylococcus aureus and Escherichia coli Isolated From Traditional and Industrial Food Samples

    Directory of Open Access Journals (Sweden)

    Mojtaba Arslani

    2017-05-01

    Full Text Available Background: Foodborne diseases are one of the serious problems in the world. Every year, more than 100 million people are affected by foodborne and waterborne diseases particularly immunocompromised diseases. Objectives: The aim of the present study was to evaluate bacterial load and antibiotic resistance pattern in bacterial isolates from food samples of meat, dairy, and pastry products from west of Tehran, Iran, during April 2007 to March 2008. Materials and Methods: A total of 1625 different food samples including dairy products, meat and pastries were collected randomly from different parts of the west of Tehran. All samples were kept at 4°C. The samples were first cultured according to the standard bacteriological methods and then Staphylococcus aureus and Escherichia coli isolates were identified using standard bacteriological tests. Antimicrobial susceptibility test was performed by disk diffusion method according to Clinical & Laboratory Standards Institute (CLSI guidelines. Results: During 2007 and 2008, 2.8% and 3% of the food samples were contaminated with S. aureus. Similarly, 3.5% and 6.4% of the food samples were contaminated with E. coli. E. coli isolates were highly resistant to amikacin and cephotaxime and this resistance was increased in 2008. Similarly S. aureus isolates were resistant to ciprofloxacin, cephotaxime, gentamicin, and tetracyclin. There was no significant difference during 2007-2008. Conclusion: The rate of contamination during 2007 was 2.8% and during 2008 was 3% for S. aureus. This strain was isolated from the food samples. Further studies should be done to determine the changes of bacterial resistance pattern for various food samples. Thus, the baseline for comparison with future prospective studies should be established, enabling the determination of trends over time.

  11. Self-sampling for human papillomavirus testing among rural young women of KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Mbatha, J N; Galappaththi-Arachchige, H N; Mtshali, A; Taylor, M; Ndhlovu, P D; Kjetland, E F; Baay, M F D; Mkhize-Kwitshana, Z L

    2017-12-06

    Cervical cancer is a major problem in women and it is important to find a suitable and acceptable screening method, especially among young in low-resource areas for future human papillomavirus (HPV) vaccine follow-up investigations. The study sought to test the acceptability of self-sampling as well as the suitability of the specimen collecting devices. Ninety-eight young women from rural KwaZulu-Natal were enrolled between March and July 2014. Collected genital specimens were transferred to colour indicator cards for HPV detection. Participants answered a questionnaire where they described their experiences with self-sampling. Samples were tested for high-risk HPV using GP5/6+ PCR. Of the enrolled participants, 91 answered questionnaires and indicated that self-sampling was preferred by 51/91 (56%) women while 40/91 (44%) indicated preference for sampling by a doctor (p = 0.023). The majority, 64% were comfortable using a swab, 22% preferred a brush while 11% were comfortable with both devices. Of the 98 self-sampled specimens 61 were negative for HPV in both specimens while 37 were HPV-positive in either brush or swab. Of the 37, 26 (70%) were HPV-positive in both brush and swab (kappa = 0.743) and 11 (30%) were discordant. Self-sampling was acceptable to the majority of participants in this rural area. The Dacron swab was the preferred device, and can be used in combination with colour indicator cards for comfortable self-sampling, easy storage and transport of specimens plus detection.

  12. Solvent extraction method for rapid separation of strontium-90 in milk and food samples

    International Nuclear Information System (INIS)

    Hingorani, S.B.; Sathe, A.P.

    1991-01-01

    A solvent extraction method, using tributyl phosphate, for rapid separation of strontium-90 in milk and other food samples has been presented in this report in view of large number of samples recieved after Chernobyl accident for checking radioactive contamination. The earlier nitration method in use for the determination of 90 Sr through its daughter 90 Y takes over two weeks for analysis of a sample. While by this extraction method it takes only 4 to 5 hours for sample analysis. Complete estimation including initial counting can be done in a single day. The chemical recovery varies between 80-90% compared to nitration method which is 65-80%. The purity of the method has been established by following the decay of yttrium-90 separated. Some of the results obtained by adopting this chemical method for food analysis are included. The method is, thus, found to be rapid and convenient for accurate estimation of strontium-90 in milk and food samples. (author). 2 tabs., 1 fig

  13. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  14. Bacteriological Analysis and Hygine Level of Food Outlets within Rufus Giwa Polytechnic, Owo, Ondo State, Nigeria.

    OpenAIRE

    Ibrahim TA; Akenroye OM; Osabiya OJ

    2013-01-01

    The bacteriological quality of three major food outlets in Rufus Giwa Polytechnic, Owo, was assessed using standard bacteriological methods. Swabs of hands of food vendors, table and plates in these outlets were assessed for total bacterial count, total coliform count and total E. coli count. A total of 789 bacterial colonies were isolated from hands of food handlers, tables and plates used for eating in the outlets. Eleven genera of bacteria were isolated and identified, they were; klebsiell...

  15. Assessment of Food Safety Knowledge, Attitude, Self-Reported Practices, and Microbiological Hand Hygiene of Food Handlers

    Science.gov (United States)

    Lee, Hui Key; Abdul Halim, Hishamuddin; Thong, Kwai Lin; Chai, Lay Ching

    2017-01-01

    Institutional foodborne illness outbreaks continue to hit the headlines in the country, indicating the failure of food handlers to adhere to safe practices during food preparation. Thus, this study aimed to compare the knowledge, attitude, and self-reported practices (KAP) of food safety assessment and microbiological assessment of food handlers’ hands as an indicator of hygiene practices in food premises. This study involved 85 food handlers working in a university located in Kuala Lumpur, Malaysia. The food safety KAP among food handlers (n = 67) was assessed using a questionnaire; while the hand swabs (n = 85) were tested for the total aerobic count, coliforms, and Escherichia coli, Staphylococcus aureus, Salmonella, Vibrio cholerae and Vibrio parahaemolyticus. The food handlers had moderate levels of food safety knowledge (61.7%) with good attitude (51.9/60) and self-reported practices (53.2/60). It is noteworthy that the good self-reported practices were not reflected in the microbiological assessment of food handlers’ hands, in which 65% of the food handlers examined had a total aerobic count ≥20 CFU/cm2 and Salmonella was detected on 48% of the food handlers’ hands. In conclusion, the suggestion of this study was that the food handlers had adequate food safety knowledge, but perceived knowledge failed to be translated into practices at work.

  16. Assessment of Food Safety Knowledge, Attitude, Self-Reported Practices, and Microbiological Hand Hygiene of Food Handlers

    Directory of Open Access Journals (Sweden)

    Hui Key Lee

    2017-01-01

    Full Text Available Institutional foodborne illness outbreaks continue to hit the headlines in the country, indicating the failure of food handlers to adhere to safe practices during food preparation. Thus, this study aimed to compare the knowledge, attitude, and self-reported practices (KAP of food safety assessment and microbiological assessment of food handlers’ hands as an indicator of hygiene practices in food premises. This study involved 85 food handlers working in a university located in Kuala Lumpur, Malaysia. The food safety KAP among food handlers (n = 67 was assessed using a questionnaire; while the hand swabs (n = 85 were tested for the total aerobic count, coliforms, and Escherichia coli, Staphylococcus aureus, Salmonella, Vibrio cholerae and Vibrio parahaemolyticus. The food handlers had moderate levels of food safety knowledge (61.7% with good attitude (51.9/60 and self-reported practices (53.2/60. It is noteworthy that the good self-reported practices were not reflected in the microbiological assessment of food handlers’ hands, in which 65% of the food handlers examined had a total aerobic count ≥20 CFU/cm2 and Salmonella was detected on 48% of the food handlers’ hands. In conclusion, the suggestion of this study was that the food handlers had adequate food safety knowledge, but perceived knowledge failed to be translated into practices at work.

  17. Comparison of sampling procedures and microbiological and non-microbiological parameters to evaluate cleaning and disinfection in broiler houses.

    Science.gov (United States)

    Luyckx, K; Dewulf, J; Van Weyenberg, S; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-04-01

    Cleaning and disinfection of the broiler stable environment is an essential part of farm hygiene management. Adequate cleaning and disinfection is essential for prevention and control of animal diseases and zoonoses. The goal of this study was to shed light on the dynamics of microbiological and non-microbiological parameters during the successive steps of cleaning and disinfection and to select the most suitable sampling methods and parameters to evaluate cleaning and disinfection in broiler houses. The effectiveness of cleaning and disinfection protocols was measured in six broiler houses on two farms through visual inspection, adenosine triphosphate hygiene monitoring and microbiological analyses. Samples were taken at three time points: 1) before cleaning, 2) after cleaning, and 3) after disinfection. Before cleaning and after disinfection, air samples were taken in addition to agar contact plates and swab samples taken from various sampling points for enumeration of total aerobic flora, Enterococcus spp., and Escherichia coli and the detection of E. coli and Salmonella. After cleaning, air samples, swab samples, and adenosine triphosphate swabs were taken and a visual score was also assigned for each sampling point. The mean total aerobic flora determined by swab samples decreased from 7.7±1.4 to 5.7±1.2 log CFU/625 cm2 after cleaning and to 4.2±1.6 log CFU/625 cm2 after disinfection. Agar contact plates were used as the standard for evaluating cleaning and disinfection, but in this study they were found to be less suitable than swabs for enumeration. In addition to measuring total aerobic flora, Enterococcus spp. seemed to be a better hygiene indicator to evaluate cleaning and disinfection protocols than E. coli. All stables were Salmonella negative, but the detection of its indicator organism E. coli provided additional information for evaluating cleaning and disinfection protocols. Adenosine triphosphate analyses gave additional information about the

  18. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    Science.gov (United States)

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  19. A comparative study of sampling techniques for monitoring carcass contamination

    NARCIS (Netherlands)

    Snijders, J.M.A.; Janssen, M.H.W.; Gerats, G.E.; Corstiaensen, G.P.

    1984-01-01

    Four bacteriological sampling techniques i.e. the excision, double swab, agar contract and modified agar contact techniques were compared by sampling pig carcasses before and after chilling. As well as assessing the advantages and disadvantages of the techniques particular attention was paid to

  20. Homogenization of food samples for gamma spectrometry using tetramethylammonium hydroxide and enzymatic digestion

    International Nuclear Information System (INIS)

    Kimi Nishikawa; Abdul Bari; Abdul Jabbar Khan; Xin Li; Traci Menia; Semkow, T.M.

    2017-01-01

    We have developed a method of food sample preparation for gamma spectrometry involving the use of tetramethylammonium hydroxide (TMAH) and/or enzymes such as α-amylase or cellulase for sample homogenization. We demonstrated the effectiveness of this method using food matrices spiked with "6"0Co, "1"3"1I, "1"3"4","1"3"7Cs, and "2"4"1Am radionuclides, homogenized with TMAH (mixed salad, parmesan cheese, and ground beef); enzymes (α-amylase for bread, and cellulase for baked beans); or α-amylase followed by TMAH (cheeseburgers). Procedures were developed which are best compromises between the degree of homogenization, accuracy, speed, and minimizing laboratory equipment contamination. Based on calculated sample biases and z-scores, our results suggest that homogenization using TMAH and enzymes would be a useful method of sample preparation for gamma spectrometry samples during radiological emergencies. (author)

  1. Reevaluation of nasal swab method for dose estimation at nuclear emergency accident

    International Nuclear Information System (INIS)

    Yamada, Yuji; Fukutsu, Kumiko; Kurihara, Osamu; Akashi, Makoto

    2008-01-01

    ICRP Publication 66 human respiratory tract model has been used extensively over in exposure dose assessment. It is well known that respiratory deposition efficiency of inhaled aerosol and its deposition region strongly depend on the particle size. In most of exposure accidents, however, nobody knows a size of inhaled aerosol. And thus two default aerosol sizes of 5μ in AMAD for the workers and 1μ in AMAD for the public are given as being representative in the ICRP model, but both sizes are not linked directly to the maximum dose. In this study, the most hazardous size to our health effects and how to estimate an intake activity was discussed from a viewpoint of emergency medicine. In exposure accident of alpha emitter such as Pu-239, lung monitor and bioassay measurements are not the best methods for rapid estimation with high sensitivity, so that an applicability of nasal swab method has been investigated. A computer software, LUDEP, was used in the calculation of respiratory deposition. It showed that the effective dose per unit intake activity strongly depended on the inhaled aerosol size. In case of Pu-239 dioxide aerosols, it was confirmed that the maximum of dose conversion factor was observed around 0.01μ. It means that this 0.01μ is the most hazardous size at exposure accident of Pu-239. From analysis of the relationship between AI and ET l deposition, it was found that the dose conversion factor from the activity deposited in ET l region also was affected by the aerosol size. The usage of the ICRP's default size in nasal swab method might cause obvious underestimation of the intake activity. Dose estimation based on nasal swab method is possible from safety side at nuclear emergency, and the availability in quantity should be reevaluated for emergency medicine considering of chelating agent administration. (author)

  2. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  3. An outbreak of norovirus gastroenteritis associated with asymptomatic food handlers in Kinmen, Taiwan

    Directory of Open Access Journals (Sweden)

    Meng-Yu Chen

    2016-05-01

    Full Text Available Abstract Background In February 2015 an outbreak of gastroenteritis occurred in a distillery in Kinmen, Taiwan. At least 450 affected employees developed the symptoms of diarrhea and vomiting after attending a lunch banquet on 6 February. Epidemiological, laboratory and environmental investigations were conducted to identify the agent and source of this outbreak. Methods A case–control study was carried out among lunch attendees from the distillery. Using a semi-structured questionnaire, food and beverage consumption in the lunch banquet was assessed, as well as demographic and clinical data of the exposed people. An outbreak case was defined as a diner who developed at least three following symptoms: diarrhea, vomiting, abdominal pain, nausea, chills and/or weakness in the 72 h following the lunch. Controls were defined as lunch attendees who did not have any of the above symptoms. Rectal swabs or stool samples of the symptomatic exposed diners and food handlers as well as food and environmental samples were collected to test potential bacteria and viruses. Norovirus was detected by reverse transcription-polymerase chain reaction and sequence analysis. An environmental assessment, including environmental inspection of the restaurant and a review of work practices of food workers, was undertaken. Results Of 363 respondents with complete data, 169 met the case definition and 111 met the control definition. Consumption of pork liver in cold appetizers (adjusted odd ratio (aOR 3.23; 95 % confidence interval (CI: 1.26–8.30 and lamb chops (aOR: 3.98, 95 % CI: 1.74–9.11 were each associated with increased risk of illness. No cases but two asymptomatic food handlers who prepared or cooked the implicated foods tested positive for norovirus genotype I.6. Food and environmental samples were negative for any bacteria. Environmental assessment indicated that hand washing facilities were not properly accessible to food handlers. Inappropriate

  4. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-16

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

  5. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

  6. Self-sampling for human papillomavirus DNA detection: a preliminary study of compliance and feasibility in BOLIVIA.

    Science.gov (United States)

    Surriabre, Pedro; Allende, Gustavo; Prado, Marcela; Cáceres, Leyddy; Bellot, Diego; Torrico, Andrea; Ustariz, Karina; Rojas, Shirley; Barriga, Jaime; Calle, Pamela; Villarroel, Ligia; Yañez, Rosse Mary; Baay, Marc; Rodriguez, Patricia; Fontaine, Véronique

    2017-12-22

    Cervical cancer incidence and mortality rates in Bolivia are among the highest in Latin America. This investigation aims to evaluate the possibility of using simple devices, e.g. a cotton swab and a glass slide, for self-sampling in order to detect human papillomavirus (HPV) DNA by PCR in cervico-vaginal cells. In the first phase of our study we evaluated the use of a glass slide as a transport medium for cervical cells. A physician took paired-cervical samples from 235 women. One sample was transported in Easyfix® solution and the other sample was smeared over a glass slide. Both were further analyzed and compared for human DNA recovery and HPV detection. A kappa value was determined to evaluate the agreement between the HPV DNA detection rates. In the second phase of the study, 222 women from the urban, peri-urban and rural regions of Cochabamba were requested to perform self-sampling using the following devices: a cotton swab combined with a glass slide, and a vaginal tampon. Women gave their opinion about the self-sampling technique. Finally, the agreement for high risk-HPV detection between self- and physician-collected samples was performed in 201 samples in order to evaluate the self-sampling technique. Firstly, the comparison between Easyfix® solution and the glass slide to transport clinical samples gave a good agreement for HPV DNA detection (κ = 0.71, 95% CI 0.60-0.81). Secondly, self-sampling, especially with cotton swab combined with glass slide, would generally be preferred over clinician sampling for a screening program based on HPV detection. Finally, we showed a good agreement between self- and physician collected samples for high risk-HPV detection (κ = 0.71, 95% CI 0.55-0.88). Simple devices such as a cotton swab and a glass slide can be used to perform self-sampling and HPV DNA detection. Furthermore, most Bolivian women preferred self-sampling over clinician-sampling for cervical cancer screening.

  7. Polyfluoroalkyl phosphate esters and perfluoroalkyl carboxylic acids in target food samples and packaging--method development and screening.

    Science.gov (United States)

    Gebbink, Wouter A; Ullah, Shahid; Sandblom, Oskar; Berger, Urs

    2013-11-01

    Polyfluoroalkyl phosphate mono-, di-, and tri-esters (mono-, di-, and triPAPs) are used to water- and grease-proof food packaging materials, and these chemicals are known precursors to perfluoroalkyl carboxylic acids (PFCAs). Existing analytical methods for PAPs lack sample clean-up steps in the sample preparation. In the present study, a method based on ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC/MS/MS) was developed and optimized for the analysis of mono-, di-, and triPAPs, including a clean-up step for the raw extracts. The method was applied to food samples and their PAP-containing packaging materials. The optimized UPLC/MS/MS method enabled the separation and identification of a total of 4 monoPAPs, 16 diPAPs, and 7 triPAPs in the technical mixture Zonyl®-RP. For sample clean-up, weak anion exchange solid phase extraction columns were tested. PAPs standard solutions spiked onto the columns were separated into a fraction containing neutral compounds (triPAPs) and a fraction with ionic compounds (mono- and diPAPs) with recoveries between 72-110%. Method limits of quantification for food samples were in the sub to low picogram per gram range. For quantitative analysis of PAPs, compound-specific labeled internal standards showed to be essential as sorption and matrix effects were observed. Mono-, di-, and/or triPAPs were detected in all food packaging materials obtained from the Swedish market. Up to nine diPAPs were detected in the food samples, with the 6:2/6:2 and 6:2/8:2 diPAPs as the dominant compounds. DiPAP concentrations in the food samples ranged from 0.9 to 36 pg/g, which was comparable to individual PFCA concentrations in the same samples. Consumption of food packed in PAP-containing materials could be an indirect source of human exposure to PFCAs.

  8. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  9. Culture methods of allograft musculoskeletal tissue samples in Australian bacteriology laboratories.

    Science.gov (United States)

    Varettas, Kerry

    2013-12-01

    Samples of allograft musculoskeletal tissue are cultured by bacteriology laboratories to determine the presence of bacteria and fungi. In Australia, this testing is performed by 6 TGA-licensed clinical bacteriology laboratories with samples received from 10 tissue banks. Culture methods of swab and tissue samples employ a combination of solid agar and/or broth media to enhance micro-organism growth and maximise recovery. All six Australian laboratories receive Amies transport swabs and, except for one laboratory, a corresponding biopsy sample for testing. Three of the 6 laboratories culture at least one allograft sample directly onto solid agar. Only one laboratory did not use a broth culture for any sample received. An international literature review found that a similar combination of musculoskeletal tissue samples were cultured onto solid agar and/or broth media. Although variations of allograft musculoskeletal tissue samples, culture media and methods are used in Australian and international bacteriology laboratories, validation studies and method evaluations have challenged and supported their use in recovering fungi and aerobic and anaerobic bacteria.

  10. Isolation of Arcobacter butzleri in environmental and food samples collected in industrial and artisanal dairy plants

    Directory of Open Access Journals (Sweden)

    Federica Giacometti

    2013-10-01

    Full Text Available This study investigated the presence of Arcobacter species in two cheese factories; a total of 22 environmental samples and 10 food samples were collected from an artisanal and an industrial cheese factory; Arcobacter species were isolated after enrichment, and isolates were identified at species level by multiplex-polymerase chain reaction (PCR assay. In the artisanal cheese factory, Arcobacter spp. were isolated from several environmental samples, cow and water buffalo raw milk and ricotta cheese. In the industrial plant, Arcobacter spp. were isolated from surfaces not in contact with food and from a cleaned surface in contact with food; no Arcobacter spp. was isolated from food. All isolates were identified as A. butzleri. We report of the presence of A. butzleri in a ready-to-eat cheese produced for retail. In addition, the isolation of A. butzleri in food processing surfaces in the two cheese factories could be assessed as a source of potential contamination for cheeses

  11. Direct PCR amplification of the HVSI region in mitochondrial DNA from buccal cell swabs

    Directory of Open Access Journals (Sweden)

    Kovačević-Grujičić Nataša

    2012-01-01

    Full Text Available Amplification of human mitochondrial DNA (mtDNA has been widely used in population genetics, human evolutionary and molecular anthropology studies. mtDNA hypervariable segments I and II (HVSI and HVSII were shown to be a suitable tool in genetic analyses due to the unique properties of mtDNA, such as the lack of recombination, maternal mode of inheritance, rapid evolutionary rate and high population-specific polymorphisms. Here we present a rapid and low-cost method for direct PCR amplification of a 330 bp fragment of HVSI from buccal cell samples. Avoiding the DNA isolation step makes this method appropriate for the analysis of a large number of samples in a short period of time. Since the transportation of samples and fieldwork conditions can affect the quality of samples and subsequent DNA analysis, we tested the effects of long-term storage of buccal cell swabs on the suitability of such samples for direct PCR amplification. We efficiently amplified a 330 bp fragment of HVSI even after the long-term storage of buccal cells at room temperature, +4°C or at -20°C, for up to eight months. All examined PCR products were successfully sequenced, regardless of sample storage time and conditions. Our results suggest that the direct PCR amplification of the HVSI region from buccal cells is a method well suited for large-scale mtDNA population studies.[Acknowledgments. This work was supported by the Ministry of Education and Science of the Republic of Serbia (Grant no. III 47025.

  12. Quantitative analysis of food and feed samples with droplet digital PCR.

    Directory of Open Access Journals (Sweden)

    Dany Morisset

    Full Text Available In this study, the applicability of droplet digital PCR (ddPCR for routine analysis in food and feed samples was demonstrated with the quantification of genetically modified organisms (GMOs. Real-time quantitative polymerase chain reaction (qPCR is currently used for quantitative molecular analysis of the presence of GMOs in products. However, its use is limited for detecting and quantifying very small numbers of DNA targets, as in some complex food and feed matrices. Using ddPCR duplex assay, we have measured the absolute numbers of MON810 transgene and hmg maize reference gene copies in DNA samples. Key performance parameters of the assay were determined. The ddPCR system is shown to offer precise absolute and relative quantification of targets, without the need for calibration curves. The sensitivity (five target DNA copies of the ddPCR assay compares well with those of individual qPCR assays and of the chamber digital PCR (cdPCR approach. It offers a dynamic range over four orders of magnitude, greater than that of cdPCR. Moreover, when compared to qPCR, the ddPCR assay showed better repeatability at low target concentrations and a greater tolerance to inhibitors. Finally, ddPCR throughput and cost are advantageous relative to those of qPCR for routine GMO quantification. It is thus concluded that ddPCR technology can be applied for routine quantification of GMOs, or any other domain where quantitative analysis of food and feed samples is needed.

  13. Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.

    Science.gov (United States)

    Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael

    2011-01-01

    New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.

  14. Food-borne norovirus-outbreak at a military base, Germany, 2009.

    Science.gov (United States)

    Wadl, Maria; Scherer, Kathrin; Nielsen, Stine; Diedrich, Sabine; Ellerbroek, Lüppo; Frank, Christina; Gatzer, Renate; Hoehne, Marina; Johne, Reimar; Klein, Günter; Koch, Judith; Schulenburg, Jörg; Thielbein, Uta; Stark, Klaus; Bernard, Helen

    2010-02-17

    associated with increased risk of disease.Norovirus was detected in 8/28 ill persons' and 4/25 canteen employees' stools, 6/55 environmental swabs and 0/33 food items. Sequences were identical in environmental and stool samples (subtype II.4 2006b), except for those of canteen employees. Control measures comprised cohort isolation of symptomatic persons, exclusion of norovirus-positive canteen employees from work and disinfection of the canteen's kitchen. Our investigation indicated that consumption of norovirus-contaminated salad caused the peak of the outbreak on 7-9 January. Strict personal hygiene and proper disinfection of environmental surfaces remain crucial to prevent norovirus transmission.

  15. Impact of enzymatic digestion on bacterial community composition in CF airway samples

    Directory of Open Access Journals (Sweden)

    Kayla M. Williamson

    2017-05-01

    Full Text Available Background Previous studies have demonstrated the importance of DNA extraction methods for molecular detection of Staphylococcus, an important bacterial group in cystic fibrosis (CF. We sought to evaluate the effect of enzymatic digestion (EnzD prior to DNA extraction on bacterial communities identified in sputum and oropharyngeal swab (OP samples from patients with CF. Methods DNA from 81 samples (39 sputum and 42 OP collected from 63 patients with CF was extracted in duplicate with and without EnzD. Bacterial communities were determined by rRNA gene sequencing, and measures of alpha and beta diversity were calculated. Principal Coordinate Analysis (PCoA was used to assess differences at the community level and Wilcoxon Signed Rank tests were used to compare relative abundance (RA of individual genera for paired samples with and without EnzD. Results Shannon Diversity Index (alpha-diversity decreased in sputum and OP samples with the use of EnzD. Larger shifts in community composition were observed for OP samples (beta-diversity, measured by Morisita-Horn, whereas less change in communities was observed for sputum samples. The use of EnzD with OP swabs resulted in significant increase in RA for the genera Gemella (p < 0.01, Streptococcus (p < 0.01, and Rothia (p < 0.01. Staphylococcus (p < 0.01 was the only genus with a significant increase in RA from sputum, whereas the following genera decreased in RA with EnzD: Veillonella (p < 0.01, Granulicatella (p < 0.01, Prevotella (p < 0.01, and Gemella (p = 0.02. In OP samples, higher RA of Gram-positive taxa was associated with larger changes in microbial community composition. Discussion We show that the application of EnzD to CF airway samples, particularly OP swabs, results in differences in microbial communities detected by sequencing. Use of EnzD can result in large changes in bacterial community composition, and is particularly useful for detection of Staphylococcus in CF OP

  16. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  17. Long-lasting stability of vaccinia virus (orthopoxvirus) in food and environmental samples.

    Science.gov (United States)

    Essbauer, S; Meyer, H; Porsch-Ozcürümez, M; Pfeffer, M

    2007-01-01

    Poxviruses are known to remain infectious in the scabs of patients for months to years. The aim of this study was to investigate viral stability in storm water, food or gauze spiked with vaccinia virus strain Munich 1 (VACV M1). Storm water, storm water supplemented with either fetal calf serum (FCS) or potting soil was stored at two different temperatures (refrigerator, room temperature; 4 degrees C/25 degrees C). In addition, we analysed the viability of VACV M1 on the surface of bread, salad, sausages and gauze bandages stored at 4 degrees C. Samples were titrated in MA 104 cells and the presence of viral DNA was demonstrated by orthopoxvirus-specific PCRs. After 2 weeks, reisolation of VACV M1 from all kinds of food, bandage and water samples except for storm water supplemented with potting soil was possible. Viral DNA was detected in almost all samples by PCR. Prolonged experiments with VACV M1-spiked storm water and storm water supplemented with FCS revealed that samples kept at 4.5 degrees C are infectious for up to 166 days. Our data demonstrate that VACV M1 has a longlasting stability in water and food. The results obtained during this study should be taken into account for risk assessment calculations for poxvirus transmission. Implying that variola virus and vaccinia virus behave in a similar way, our data call for sophisticated countermeasures in cases of a variola release in biological warfare.

  18. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  19. Detection and differentiation of Mycoplasma gallisepticum and Mycoplasma synoviaeby PCR from tracheal swabs from birds with respiratory symptoms

    International Nuclear Information System (INIS)

    Ventura, Cesar E; Ramirez, Gloria; Vera, Victor

    2012-01-01

    Mycoplasmas are worldwide pathogens that affect the poultry industry causing respiratory illness which cause a negative economic impact. Two mycoplasmas species are the most important in the commercial poultry: mycoplasma gallisepticum (MG) and mycoplasma synoviae (MS). By its importance and necessity to know and differentiate between mycoplasmas species in local's poultry houses this study used the PCR technique like a diagnosis tool, using tracheal swabs from bird with respiratory symptoms. A total of 91 samples from broilers, layers and breeders farms located in the departments of Cundinamarca and Boyaca was processed. The punctual prevalence founded in this study was 39.6 % for mg and 47.3 % for MS. statistical differences for type of production and positive samples for mg y MS (p < 0.05) were founded, a bigger number of positive samples from layers and breeder in comparison to broilers were found. In the same way, the positive samples for the layers and breeder from the age group between 20 and 60 weeks was greater, while for the broilers group most of the positive samples were from five weeks old birds for mg and two weeks old birds for MS.

  20. Detection of triglycerides using immobilized enzymes in food and biological samples

    Science.gov (United States)

    Raichur, Ashish; Lesi, Abiodun; Pedersen, Henrik

    1996-04-01

    A scheme for the determination of total triglyceride (fat) content in biomedical and food samples is being developed. The primary emphasis is to minimize the reagents used, simplify sample preparation and develop a robust system that would facilitate on-line monitoring. The new detection scheme developed thus far involves extracting triglycerides into an organic solvent (cyclohexane) and performing partial least squares (PLS) analysis on the NIR (1100 - 2500 nm) absorbance spectra of the solution. A training set using 132 spectra of known triglyceride mixtures was complied. Eight PLS calibrations were generated and were used to predict the total fat extracted from commercial samples such as mayonnaise, butter, corn oil and coconut oil. The results typically gave a correlation coefficient (r) of 0.99 or better. Predictions were typically within 90% and better at higher concentrations. Experiments were also performed using an immobilized lipase reactor to hydrolyze the fat extracted into the organic solvent. Performing PLS analysis on the difference spectra of the substrate and product could enhance specificity. This is being verified experimentally. Further work with biomedical samples is to be performed. This scheme may be developed into a feasible detection method for triglycerides in the biomedical and food industries.

  1. Control System Radioactive Contamination in Food Samples in Poland

    International Nuclear Information System (INIS)

    Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Smagala, G.; Swietochowska, J.

    2001-01-01

    Full text: The analyses of the level of radioactive contamination in food samples are carried out by the Service for Measurements of Radioactive Contamination (SMRC) in Poland. The Service was brought into existence in 1961. The Service comprises of a network of measurement stations and the Centre of Radioactive Contamination Measurements (CRCM). The duty of the Centre is being executed by the Central Laboratory for Radiological Protection (CLRP). The uniform methods of sampling are used in measurement stations. All important foodstuff: milk, meat, vegetables, fruit, cereals are controlled in the Service stations. The radiochemical and spectrometric methods are used to determine the activity of radioactive isotopes. The standard equipment of the measurement station is the measurement system type SAPOS-90 and multichannel analyser with scintillation or germanium detector. The structure of the Service, kinds of samples tested by each station, program of sampling in normal and during accident situation are presented in this paper. (author)

  2. Evaluation of the effects of storage in two different swab fabrics and under three different transport conditions on recovery of aerobic and anaerobic bacteria

    NARCIS (Netherlands)

    Roelofsen, E.; Leeuwen, M. van; Meijer-Severs, G.J.; Wilkinson, M.H.F.; Degener, J.E.

    Recovery of six anaerobic and five aerobic pathogens from viscose swabs and polyurethane swabs (Culturette EZ) was evaluated quantitatively, and transport in aerobic dry tubes, aerobic Amies transport medium (Transwab), and anaerobic universal transport medium (Port-a-Cul) was compared. The

  3. Microbiological sampling plan based on risk classification to verify supplier selection and production of served meals in food service operation.

    Science.gov (United States)

    Lahou, Evy; Jacxsens, Liesbeth; Van Landeghem, Filip; Uyttendaele, Mieke

    2014-08-01

    Food service operations are confronted with a diverse range of raw materials and served meals. The implementation of a microbial sampling plan in the framework of verification of suppliers and their own production process (functionality of their prerequisite and HACCP program), demands selection of food products and sampling frequencies. However, these are often selected without a well described scientifically underpinned sampling plan. Therefore, an approach on how to set-up a focused sampling plan, enabled by a microbial risk categorization of food products, for both incoming raw materials and meals served to the consumers is presented. The sampling plan was implemented as a case study during a one-year period in an institutional food service operation to test the feasibility of the chosen approach. This resulted in 123 samples of raw materials and 87 samples of meal servings (focused on high risk categorized food products) which were analyzed for spoilage bacteria, hygiene indicators and food borne pathogens. Although sampling plans are intrinsically limited in assessing the quality and safety of sampled foods, it was shown to be useful to reveal major non-compliances and opportunities to improve the food safety management system in place. Points of attention deduced in the case study were control of Listeria monocytogenes in raw meat spread and raw fish as well as overall microbial quality of served sandwiches and salads. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Analysis of Cl, Mn, Na, Zn in Food Samples by a Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Moon, Jong Hwa; Kim, Sun Ha; Chung, Yong Sam; Lee, Ok Hee

    2008-01-01

    Due to their westernized dietary habit, Korean children are still threatened by the increasing risks of chronic disease such as obesity, hypertension, low immunity, etc. In addition, they are often exposed to a deficiency of Ca, Mg, Fe and micro-minerals which are necessary for their growth, immunity, and prevention of anemia. Nonetheless, the nutritional adequacy of mineral intakes for children is difficult to assess because of a lack of related studies and a nutritional database with respect to Korean children's foods. In this study, ninety kinds of foods consisting of lunch meals from an elementary and a middle school and children's favorite snacks were collected and prepared for an analysis. INAA which has an advantage of a non-destructive technique was employed to determine the elements like Cl, Mn, Na, Cl in the pretreated food samples. Quality control was carried out by using certified reference materials. From the analytical results, elemental concentration range in the collected samples according to the food groups was summarized

  5. Detection of newly produced T and B lymphocytes by digital PCR in blood stored dry on nylon flocked swabs.

    Science.gov (United States)

    Tessitore, Marion Vaglio; Sottini, Alessandra; Roccaro, Aldo M; Ghidini, Claudia; Bernardi, Simona; Martellosio, Giovanni; Serana, Federico; Imberti, Luisa

    2017-04-05

    A normal number of T-cell receptor excision circles (TRECs) and K-deleting recombination excision circles (KRECs) is considered a biomarker for adequate new T- and B-cell production. In newborns, detection of TRECs and KRECs by real time PCR from dried blood spotted on filter paper is used for the screening of severe immunodeficiency. In adults, elderly and during diseases, where the number of TRECs is lower than in newborns and children, a large amount of DNA and a sensitive method of amplification are necessary to identify newly produced lymphocytes. DNA was prepared from blood of 203 healthy adults (range: 18-91 years old) absorbed for 10 s on flocked swabs and let to dry, or from peripheral blood mononuclear cells. DNA was subjected to digital PCR and to well established conventional real time PCR-based method using TREC- and KREC-specific primers and probes. The number of TRECs and KRECs was expressed per mL of blood. Statistical analysis was performed by nested ANOVA, Pearson coefficient of determination, and by linear regression tests. The novel method for the storage of dried blood on nylon flocked swabs and the use of digital PCR allow quantification of TRECs and KRECs with high degree of sensitivity, specificity, accuracy, and precision. TRECs and KRECs were amplified by digital PCR in all tested blood samples, including those obtained from elderly individuals (>70 years old) and that were negative by real time PCR. Furthermore, values of TRECs and KRECs obtained by digital PCR were in the range of those acquired by real time PCR. Our findings demonstrate that DNA isolation from dried blood on flocked swabs followed by digital PCR-based analysis represents a useful tool for studying new lymphocyte production in adults and elderly individuals. This suggests the potential use of the methodology when monitoring of clinical variables is limited by the number of molecules that can be amplified and detected, such as in patients with immunodeficiency or under

  6. Salmonella spp. contamination in commercial layer hen farms using different types of samples and detection methods.

    Science.gov (United States)

    Soria, M C; Soria, M A; Bueno, D J; Godano, E I; Gómez, S C; ViaButron, I A; Padin, V M; Rogé, A D

    2017-08-01

    The performance of detection methods (culture methods and polymerase chain reaction assay) and plating media used in the same type of samples were determined as well as the specificity of PCR primers to detected Salmonella spp. contamination in layer hen farms. Also, the association of farm characteristics with Salmonella presence was evaluated. Environmental samples (feces, feed, drinking water, air, boot-swabs) and eggs were taken from 40 layer hen houses. Salmonella spp. was most detected in boot-swabs taken around the houses (30% and 35% by isolation and PCR, respectively) follow by fecal samples (15.2% and 13.6% by isolation and PCR, respectively). Eggs, drinking water, and air samples were negative for Salmonella detection. Salmonella Schwarzengrund and S. Enteritidis were the most isolated serotypes. For plating media, relative specificity was 1, and the relative sensitivity was greater for EF-18 agar than XLDT agar in feed and fecal samples. However, relative sensitivity was greater in XLDT agar than EF-18 agar for boot-swab samples. Agreement was between fair to good depending on the sample, and it was good between isolation and PCR (feces and boot-swabs), without agreement for feed samples. Salmonella spp. PCR was positive for all strains, while S. Typhimurium PCR was negative. Salmonella Enteritidis PCR used was not specific. Based in the multiple logistic regression analyses, categorization by counties was significant for Salmonella spp. presence (P-value = 0.010). This study shows the importance of considering different types of samples, plating media and detection methods during a Salmonella spp. monitoring study. In addition, it is important to incorporate the sampling of floors around the layer hen houses to learn if biosecurity measures should be strengthened to minimize the entry and spread of Salmonella in the houses. Also, the performance of some PCR methods and S. Enteritidis PCR should be improved, and biosecurity measures in hen farms must be

  7. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Science.gov (United States)

    2010-01-01

    ... laboratory within one day. If delivery is delayed, samples should be refrigerated. (a) For egg- and meat-type chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...

  8. Preparation of Environmental and Food Samples to Support the Heavy Metals Detection by Stripping Electrochemical

    International Nuclear Information System (INIS)

    Iswani S

    2002-01-01

    Preparation of environmental and food samples to support the heavy metals detection by stripping electrochemistry was done. The water samples taken directly from the ground water were acidified with 1 mL of HNO 3 acic suprapure was not digested, while the soils samples which have already dried in the oven at 105 o C, ware grinded and sieved through 150 μm, werte digested with HNO 3 acic suprapure in the digestion bomb at 150 o C for 3-4 hours. The mussels samples which have already freezed in the freezer were peeled, dried with N 2 liquid, grinded and dried again in the freeze drier at the pressure of ≅ 10 -2 mBar, and then were grinded again, weighted, digested with HNO 3 acic and HClO 4 suprapure in the digestion bomb at 150 o C for 3 hours. Food samples were homogenized by electric mixer, dried with freeze dried, homogenized again by using ZrO 2 ball mill, weighted, digested by HPA (high Pressure Asher). The heavy metals in the food samples solution of digestion product were detected by using Polarographic Analyzer EGandG of SWV and DPASV methods, while in the water, soils and the mussels solution were detected by using PDV 2000 and Polarograf E-505, DPASV method. The method validity were tested with SRM materials such as soil-5, soil-7, water W-4, and coppepoda. The heavy metals detection results in the water, soils, mussels, and food by electrochemical method were reported in this paper. (author)

  9. Data in support of the detection of genetically modified organisms (GMOs) in food and feed samples.

    Science.gov (United States)

    Alasaad, Noor; Alzubi, Hussein; Kader, Ahmad Abdul

    2016-06-01

    Food and feed samples were randomly collected from different sources, including local and imported materials from the Syrian local market. These included maize, barley, soybean, fresh food samples and raw material. GMO detection was conducted by PCR and nested PCR-based techniques using specific primers for the most used foreign DNA commonly used in genetic transformation procedures, i.e., 35S promoter, T-nos, epsps, cryIA(b) gene and nptII gene. The results revealed for the first time in Syria the presence of GM foods and feeds with glyphosate-resistant trait of P35S promoter and NOS terminator in the imported soybean samples with high frequency (5 out of the 6 imported soybean samples). While, tests showed negative results for the local samples. Also, tests revealed existence of GMOs in two imported maize samples detecting the presence of 35S promoter and nos terminator. Nested PCR results using two sets of primers confirmed our data. The methods applied in the brief data are based on DNA analysis by Polymerase Chain Reaction (PCR). This technique is specific, practical, reproducible and sensitive enough to detect up to 0.1% GMO in food and/or feedstuffs. Furthermore, all of the techniques mentioned are economic and can be applied in Syria and other developing countries. For all these reasons, the DNA-based analysis methods were chosen and preferred over protein-based analysis.

  10. [Analysis on contamination of zearalenone and dietary exposure assessment in food samples of Shaanxi Province in 2013-2016].

    Science.gov (United States)

    Hu, Jiawei; Wang, Caixia; Tian, Li; Wang, Minjuan; Guo, Rong; Qiao, Haiou

    2017-07-01

    To investigate the contamination of zearalenone in food in Shaanxi Province, and to assess the dietary zearalenone exposure and the health risk of intaking zearalenone from corn products for Shaanxi residents. In 2013-2016, samples of five kinds of food including grains, vegetable oil, liquor and infants' food were collected randomly from ten cities, and determined with ultra-performance liquid chromatography. Dietary intake assessment of human exposure to zearalenone was carried out in combination of food consumption data with concentration of zearalenone. 1193 samples were detected zearalenone and the total detection rate was 17. 27%, with the mean value of 13. 5 μg/kg. Among all food samples, oil products were more seriously polluted than other kinds of foods, its detection rate was 79. 37%. And 12 samples of grain products exceed the standard, the exceeding standard rate was 1. 64%, which were all corn products. The level of zearalenone detected in wheat flour, rice, millet, beer and bakery products was low. The overall level of zearalenone contamination inmarket food is common, but corn products may be the severely contaminated foods with zearalenone in Shaanxi Province. The risk assessmentresult suggests that the current dietary intake of zearalenone from corn products in Shaanxi Province has no appreciable effect on health, however, the concentrations of zearalenone in corn products are relatively high, and need to be monitored in the future.

  11. Acceptability of Sexually Transmitted Infection Testing Using Self-Collected Vaginal Swabs among College Women

    Science.gov (United States)

    Fielder, Robyn L.; Carey, Kate B.; Carey, Michael P.

    2013-01-01

    Objective: To assess the acceptability of sexually transmitted infection (STI) testing using self-collected vaginal swabs (SCVS) among college women. Participants: First-year female students ("N" = 483). Methods: Participants were offered free testing for 3 STIs using SCVS in April 2010 and later completed a survey regarding their…

  12. Implementation of hazard analysis and critical control point (HACCP) system in a food service unit serving immuno-suppressed patient diets / E.E. Vermeulen

    OpenAIRE

    Vermeulen, Emma Emmerenza

    2006-01-01

    Main aim: To supply recommendations to implement a Hazard Analysis of Critical Control Points (HACCP) system in a hospital food service unit serving low bacterial diets in order to prevent or decrease the infection rates in Hematopoietic Stem Cell Transplant (HSCT) patients. Objectives: Firstly, to investigate the current food safety and hygiene status in a hospital food service unit, serving low bacterial diets, by means of a questionnaire and bacterial swabs taken from the...

  13. Comparison of foam swabs and toothbrushes as oral hygiene interventions in mechanically ventilated patients: a randomised split mouth study.

    Science.gov (United States)

    Marino, Paola J; Hannigan, Ailish; Haywood, Sean; Cole, Jade M; Palmer, Nicki; Emanuel, Charlotte; Kinsella, Tracey; Lewis, Michael A O; Wise, Matt P; Williams, David W

    2016-01-01

    During critical illness, dental plaque may serve as a reservoir of respiratory pathogens. This study compared the effectiveness of toothbrushing with a small-headed toothbrush or a foam-headed swab in mechanically ventilated patients. This was a randomised, assessor-blinded, split-mouth trial, performed at a single critical care unit. Adult, orally intubated patients with >20 teeth, where >24 hours of mechanical ventilation was expected were included. Teeth were cleaned 12-hourly using a foam swab or toothbrush (each randomly assigned to one side of the mouth). Cleaning efficacy was based on plaque scores, gingival index and microbial plaque counts. High initial plaque (mean=2.1 (SD 0.45)) and gingival (mean=2.0 (SD 0.54)) scores were recorded for 21 patients. A significant reduction compared with initial plaque index occurred using both toothbrushes (mean change=-1.26, 95% CI -1.57 to -0.95; poral health, which improved after brushing with a toothbrush or foam swab. Both interventions were equally effective at removing plaque and reducing gingival inflammation. NCT01154257; Pre-results.

  14. Analysis of Cl, Mn, Na, Zn in Food Samples by a Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jong Hwa; Kim, Sun Ha; Chung, Yong Sam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Ok Hee [YongIn University, Yongin (Korea, Republic of)

    2008-10-15

    Due to their westernized dietary habit, Korean children are still threatened by the increasing risks of chronic disease such as obesity, hypertension, low immunity, etc. In addition, they are often exposed to a deficiency of Ca, Mg, Fe and micro-minerals which are necessary for their growth, immunity, and prevention of anemia. Nonetheless, the nutritional adequacy of mineral intakes for children is difficult to assess because of a lack of related studies and a nutritional database with respect to Korean children's foods. In this study, ninety kinds of foods consisting of lunch meals from an elementary and a middle school and children's favorite snacks were collected and prepared for an analysis. INAA which has an advantage of a non-destructive technique was employed to determine the elements like Cl, Mn, Na, Cl in the pretreated food samples. Quality control was carried out by using certified reference materials. From the analytical results, elemental concentration range in the collected samples according to the food groups was summarized.

  15. Highly conserved intragenic HSV-2 sequences: Results from next-generation sequencing of HSV-2 UL and US regions from genital swabs collected from 3 continents.

    Science.gov (United States)

    Johnston, Christine; Magaret, Amalia; Roychoudhury, Pavitra; Greninger, Alexander L; Cheng, Anqi; Diem, Kurt; Fitzgibbon, Matthew P; Huang, Meei-Li; Selke, Stacy; Lingappa, Jairam R; Celum, Connie; Jerome, Keith R; Wald, Anna; Koelle, David M

    2017-10-01

    Understanding the variability in circulating herpes simplex virus type 2 (HSV-2) genomic sequences is critical to the development of HSV-2 vaccines. Genital lesion swabs containing ≥ 10 7 log 10 copies HSV DNA collected from Africa, the USA, and South America underwent next-generation sequencing, followed by K-mer based filtering and de novo genomic assembly. Sites of heterogeneity within coding regions in unique long and unique short (U L _U S ) regions were identified. Phylogenetic trees were created using maximum likelihood reconstruction. Among 46 samples from 38 persons, 1468 intragenic base-pair substitutions were identified. The maximum nucleotide distance between strains for concatenated U L_ U S segments was 0.4%. Phylogeny did not reveal geographic clustering. The most variable proteins had non-synonymous mutations in < 3% of amino acids. Unenriched HSV-2 DNA can undergo next-generation sequencing to identify intragenic variability. The use of clinical swabs for sequencing expands the information that can be gathered directly from these specimens. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Commercial nonindustrial production of pastries and ice cream in Naples, Italy: results from the inspection of 34 food businesses during a 2-year surveillance study

    Directory of Open Access Journals (Sweden)

    Lucia Tanucci Nannini

    2010-03-01

    Full Text Available

    Background: Ice cream and cream-based pastries are an excellent media for the growth of pathogenic microorganisms. Foods that are prepared without due respect to the rules of food hygiene can carry microorganisms and/or toxins and could be responsible of toxinfections. The main objective of this study was to obtain an overall picture of the hygiene/sanitation conditions found in businesses that produce hand-made pastries and/or ice cream in Naples, Italy.

    Methods: We inspected 34 businesses to assess the following aspects: hygiene/sanitation conditions of the work area and equipment, implementation of good food hygiene principles, evaluation of HACCP plans, licensing/authorization, quality control and sampling protocols, as well as systems for ensuring food traceability. In 28 of the businesses, samples (environment, foods, workers were collected for microbiological analysis.

    Results: Sanctions were issued for nonconformities in 8 businesses (23.5%, and 25 businesses (73.5% received warnings with orders to correct minor nonconformities (inadequate documentation of compliance with current regulations, incorrect implementation of the quality-control protocol within specified time periods. Microbiological analyses revealed irregularities in 24/28 businesses (85.7%, and 138 of the 280 samples collected displayed contamination levels exceeding the limits adopted for this study (49.3%. In particular, 80% of the surfaces sampled and 23.8% of the hand swabs collected were shown to be contaminated. All food samples collected met the process-hygiene and food-safety standards prescribed by the European Community. Results obtained were statistically significant (p < 0.05.

    Conclusions: Our experience of food safety surveillance system indicates that Neapolitan food business operators involved in the production of hand-made ice cream or pastries do not

  17. Radiological study of brackish and fresh water food samples in Lagos and Ondo states, southwestern Nigeria

    International Nuclear Information System (INIS)

    Ojo, T.J.; Ojo, O.C.

    2007-01-01

    Measurement of the average radioactivity concentration in brackish and fresh water food samples in Lagos and Ondo States of Nigeria was carried out using a very sensitive gamma spectroscopic system consisting of a 76 mm x 76 mm Nal (TI) scintillation detector coupled to a computerized ACCUSPEC installation. All the radionuclide detected are traceable to the naturally occurring 4 ''0K and ''2''3''2Th. The average concentrations of ''2''3''8U and ''2''3''2Th were found to be higher in brackish water food samples, 50.92±7.04 Bq/kg and 24.60± 6.47 Bq/kg respectively. The average concentration of ''4''0K was found to be higher in food samples got from freshwater, 738.94±84.81Bq/kg

  18. Carotene location in processed food samples measured by cryo In-SEM Raman.

    Science.gov (United States)

    Lopez-Sanchez, Patricia; Schumm, Stephan; Pudney, Paul D A; Hazekamp, Johan

    2011-09-21

    Cryo In-SEM Raman has been used for the first time to localise carotene compounds in a food matrix. Raman spectra of lycopene and β-carotene have been obtained from sampling oil droplets and plant cell structures visualised with cryo-SEM in tomato and carrot based emulsions containing 5% oil. It was possible to identify the carotenoids in both the oil droplets and the cell walls. Furthermore our results gave some indication that the carotenoids were in the non-crystalline state. It has been suggested that a higher amount of carotenes solubilised into the oil phase of the food matrix would lead to a higher bioaccessibility, thus understanding the effect of processing conditions on micronutrients distribution in a food matrix might help the design of plant based food products with a better nutritional quality. This shows improved structural characterisation of the cryo-SEM with the molecular sensitivity of Raman spectroscopy as a promising approach for complex biological problems.

  19. Year-round prevalence of norovirus in the environment of catering companies without a recently reported outbreak of gastroenteritis.

    Science.gov (United States)

    Boxman, Ingeborg L A; Verhoef, Linda; Dijkman, Remco; Hägele, Geke; Te Loeke, Nathalie A J M; Koopmans, Marion

    2011-05-01

    Food handlers play an important role in the transmission of norovirus (NoV) in food-borne outbreaks of gastroenteritis (GE). In a year-round prevalence study, the prevalence of NoV in catering companies without recently reported outbreaks of GE was investigated and compared to the observed prevalence in catering companies with recently reported outbreaks. Swab samples were collected from surfaces in the kitchens and (staff) bathrooms in 832 randomly chosen companies and analyzed for the presence of NoV RNA. In total, 42 (1.7%) out of 2,496 environmental swabs from 35 (4.2%) catering companies tested positive. In contrast, NoV was detected in 147 (39.7%) of the 370 samples for 44 (61.1%) of the 72 establishments associated with outbreaks of gastroenteritis. NoV-positive swabs were more frequently found in winter, in specific types of companies (elderly homes and lunchrooms), and in establishments with separate bathrooms for staff. We found a borderline association with population density but no relation to the number of employees. Sequence analysis showed that environmental strains were interspersed with strains found in outbreaks of illness in humans. Thus, the presence of NoV in catering companies seemed to mirror the presence in the population but was strongly increased when associated with food-borne GE. Swabs may therefore serve as a valuable tool in outbreak investigations for the identification of the causative agent, although results should be interpreted with care, taking into account all other epidemiological data.

  20. Quantification of uncertainty in gamma spectrometric analysis of food and environmental samples

    International Nuclear Information System (INIS)

    Yii Mei Wo; Zaharudin Ahmad; Norfaizal Mohamed

    2005-01-01

    Gamma Spectrometry is widely used to determine the activity of gamma-ray emitter radionuclide inside a sample. Reporting the activity of the measurement for a sample should not be a single value only but it shall be associated with a reasonable uncertainty value since disintegration of radionuclide is a random/spontaneous process. This paper will focus on how the uncertainty was estimated, quantified and calculated, when measuring the activity of Cs-134 and Cs-137 in food and Ra-226, Ra-228 and K-40 in the environmental samples. (Author)

  1. Laser Scribed Graphene Biosensor for Detection of Biogenic Amines in Food Samples Using Locally Sourced Materials

    Directory of Open Access Journals (Sweden)

    Diana C. Vanegas

    2018-04-01

    Full Text Available In foods, high levels of biogenic amines (BA are the result of microbial metabolism that could be affected by temperatures and storage conditions. Thus, the level of BA is commonly used as an indicator of food safety and quality. This manuscript outlines the development of laser scribed graphene electrodes, with locally sourced materials, for reagent-free food safety biosensing. To fabricate the biosensors, the graphene surface was functionalized with copper microparticles and diamine oxidase, purchased from a local supermarket; and then compared to biosensors fabricated with analytical grade materials. The amperometric biosensor exhibits good electrochemical performance, with an average histamine sensitivity of 23.3 µA/mM, a lower detection limit of 11.6 µM, and a response time of 7.3 s, showing similar performance to biosensors constructed from analytical grade materials. We demonstrated the application of the biosensor by testing total BA concentration in fish paste samples subjected to fermentation with lactic acid bacteria. Biogenic amines concentrations prior to lactic acid fermentation were below the detection limit of the biosensor, while concentration after fermentation was 19.24 ± 8.21 mg histamine/kg, confirming that the sensor was selective in a complex food matrix. The low-cost, rapid, and accurate device is a promising tool for biogenic amine estimation in food samples, particularly in situations where standard laboratory techniques are unavailable, or are cost prohibitive. This biosensor can be used for screening food samples, potentially limiting food waste, while reducing chances of foodborne outbreaks.

  2. National guidelines for the use of antibiotics in hospitalised adult patients: the SWAB guidelines revisited

    NARCIS (Netherlands)

    Prins, J. M.; Kullberg, B. J.; Gyssens, I. C.

    2005-01-01

    Since 1996, the Dutch Working Party on Antibiotic Policy (Stichting Werkgroep AntibioticaBeleid, SWAB) has been developing national guidelines for the use of antibiotics in hospitalised adult patients. As a result of both an inventory of the wishes of the users of these guidelines and the recently

  3. Food-borne norovirus-outbreak at a military base, Germany, 2009

    Directory of Open Access Journals (Sweden)

    Hoehne Marina

    2010-02-01

    January (aOR: 15.7; 95%CI: 2.2-74.1 were independently associated with increased risk of disease. Norovirus was detected in 8/28 ill persons' and 4/25 canteen employees' stools, 6/55 environmental swabs and 0/33 food items. Sequences were identical in environmental and stool samples (subtype II.4 2006b, except for those of canteen employees. Control measures comprised cohort isolation of symptomatic persons, exclusion of norovirus-positive canteen employees from work and disinfection of the canteen's kitchen. Conclusions Our investigation indicated that consumption of norovirus-contaminated salad caused the peak of the outbreak on 7-9 January. Strict personal hygiene and proper disinfection of environmental surfaces remain crucial to prevent norovirus transmission.

  4. Diversity and killer activity of yeasts in Malaysian fermented food samples.

    Science.gov (United States)

    Lim, S L; Tay, S T

    2011-08-01

    The biodiversity and the killer activity of yeasts isolated from various types of fermented food in Malaysia were investigated in this study. Of 252 yeasts isolated from 48 fermented food samples in this study, 19 yeast species were identified based on sequence analysis of the ITS1-5.8S-ITS2 partial fragments of the yeasts. A total of 29 (11.5%) of the yeast isolates demonstrated killer activity to at least one Candida species tested in this study; including 22 isolates of Trichosporon asahii, 4 isolates of Pichia anomala, and one isolate each of Pichia norvegensis, Pichia fermentans and Issatchenkia orientalis, respectively. The presence of killer yeasts reflects antagonism that occurs during microbial interaction in the fermented food, whereby certain yeasts produce killer toxins and possibly other toxic substances in competition for limited nutrients and space. The anti-Candida activity demonstrated by killer yeasts in this study should be further explored for development of alternative therapy against candidiasis.

  5. Microbial Safety of Low Water Activity Foods: Study of Simulated and Durban Household Samples

    Directory of Open Access Journals (Sweden)

    O. A. Ijabadeniyi

    2017-01-01

    Full Text Available Sixty household low water activity foods were examined and a simulative study was conducted in a high sugar, low aw almond and macadamia butter to determine the survival of Bacillus cereus and Staphylococcus aureus ATCC 25923. Results obtained from 60 low aw samples collected at household level had some significant differences (P≤0,05 within food categories amongst the various tests. Spices had the highest number of aerobic bacteria, aerobic spore-formers, anaerobic spore-formers, and S. aureus. Mean aerobic colony counts for nuts and spices were 2.30 log CFU/g and 4.40 log CFU/g, respectively. Pathogens such as Escherichia coli and Cronobacter sakazakii were present in nuts, whilst Salmonella spp. was present in chocolates. This implies that certain low aw foods may present a public health risk. In the simulative study, temperature and high sucrose concentrations played a significant role in the survival of B. cereus and S. aureus ATCC 25923. B. cereus was found to be more osmotolerant at both reduced and elevated temperatures (18°C and 25°C in the 12% sucrose sample in both butters, whilst S. aureus ATCC 25923 seemed to grow better in sucrose-free samples at both temperatures in both butters. This implies that certain low aw foods may present a public health risk. Also, B. cereus, being a spore-forming bacterium, can be osmotolerant at both reduced and elevated temperatures.

  6. Simultaneous identification of synthetic and natural dyes in different food samples by UPLC-MS

    Science.gov (United States)

    Mandal, Badal Kumar; Mathiyalagan, Siva; Dalavai, Ramesh; Ling, Yong-Chien

    2017-11-01

    Fast foods and variety food items are populating among the food lovers. To improve the appearance of the food product in surviving gigantic competitive environment synthetic or natural food dyes are added to food items and beverages. Although regulatory bodies permit addition of natural colorants due to its safe and nontoxic nature in food, synthetic dyes are stringently controlled in all food products due to their toxicity by regulatory bodies. Artificial colors are need certification from the regulatory bodies for human consumption. To analyze food dyes in different food samples many analytical techniques are available like high pressure liquid chromatography (HPLC), thin layer chromatography (TLC), spectroscopic and gas chromatographic methods. However all these reported methods analyzed only synthetic dyes or natural dyes. Not a single method has analyzed both synthetic and natural dyes in a single run. In this study a robust ultra-performance liquid chromatographic method for simultaneous identification of 6 synthetic dyes (Tartrazine, Indigo carmine, Briliant blue, Fast green, malachite green, sunset yellow) and one natural dye (Na-Cu-Chlorophyllin) was developed using acquitic UPLC system equipped with Mass detector and acquity UPLC HSS T3 column (1.8 μm, 2.1 × 50 mm, 100Å). All the dyes were separated and their masses were determined through fragments’ masses analyses.

  7. Diagnosis of visceral Leishmaniasis in asymptomatic dogs by the KDNA PCR-hybridization assay using noninvasive samples

    International Nuclear Information System (INIS)

    Leite, Rodrigo Souza; Andrade, Antero Silva Ribeiro de; Ferreira, Sydney de Almeida; Ituassu, Leonardo Trindade; Melo, Maria Norma de

    2009-01-01

    The visceral leishmaniasis (VL) in Brazil is caused by Leishmania (Leishmania) chagasi and the asymptomatic dogs may transmit the parasite to sand flies vectors. The VL epidemiological control in Brazil involves the elimination of seropositive dogs, insecticide treatment and systematic treatment of human cases. Therefore, the accurate diagnosis is important in order to avoid the disease transmission or unnecessary culling of dogs. Serological tests are used for screening of dogs. However, these techniques present limitations. The Polymerase Chain Reaction (PCR) is an attractive alternative to the diagnosis in this context; but non-invasive samplings have great importance because they are simpler, painless and less resisted by dog-owners. This study aimed at evaluating conjunctival swab (CS) for canine VL diagnosis. In this methodology a sterile cotton swab is used to sampling the dog conjunctiva in both eyes. Thirty asymptomatic seropositive dogs were used. The samples were analyzed by the kDNA PCR-hybridization procedure in which the PCR products are hybridized with cloned kDNA mini-circles labeled with 32 P[]dCTP. In addition, blood (B) was collected from each animal. L. chagasi was identified in 90% of CS samples and 13,6% of B samples. The high sensitivity obtained with asymptomatic dogs, in which the diagnosis is more difficult due the low number of parasites in the samples, allow concluding that the conjunctival swab associated to the kDNA PCR-hybridization assay provides a valuable alternative tool for the direct diagnosis of canine leishmaniasis. (author)

  8. Enrichment of Acinetobacter spp. from food samples.

    Science.gov (United States)

    Carvalheira, Ana; Ferreira, Vânia; Silva, Joana; Teixeira, Paula

    2016-05-01

    Relatively little is known about the role of foods in the chain of transmission of acinetobacters and the occurrence of different Acinetobacter spp. in foods. Currently, there is no standard procedure to recover acinetobacters from food in order to gain insight into the food-related ecology and epidemiology of acinetobacters. This study aimed to assess whether enrichment in Dijkshoorn enrichment medium followed by plating in CHROMagar™ Acinetobacter medium is a useful method for the isolation of Acinetobacter spp. from foods. Recovery of six Acinetobacter species from food spiked with these organisms was compared for two selective enrichment media (Baumann's enrichment and Dijkshoorn's enrichment). Significantly (p enrichment. Next, the Dijkshoorn's enrichment followed by direct plating on CHROMagar™ Acinetobacter was applied to detect Acinetobacter spp. in different foods. Fourteen different presumptive acinetobacters were recovered and assumed to represent nine different strains on the basis of REP-PCR typing. Eight of these strains were identified by rpoB gene analysis as belonging to the species Acinetobacter johnsonii, Acinetobacter calcoaceticus, Acinetobacter guillouiae and Acinetobacter gandensis. It was not possible to identify the species level of one strain which may suggests that it represents a distinct species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Real-Time Polymerase Chain Reaction Detection of Trichomonas vaginalis from vaginal swabs: Validation of a Diagnostic Method and Preliminary Epidemiological Application

    Directory of Open Access Journals (Sweden)

    Carlo Mengoli

    2009-06-01

    Full Text Available Background Trichomonas vaginalis is the most common nonviral sexually trasmitted diseases (STDs agent. For females, the diagnostic gold standard is the culture of vaginal swab, which is labour-exacting.The direct microscopic examination of vaginal secretions is the most used approach, but its sensitivity depends on the skill of the observer. Objectives We evaluated an original real-time TaqMan-based Polymerase Chain Reaction (PCR technique.The scope of the study was to confirm the effectiveness of the molecular approach in a clinical context and to explore its relevance to an epidemiological investigation. Study Design a ß-tubulin gene was chosen as target sequence.The assay was designed to exploit the quantitative potential of the TaqMan procedure.The population sample was 583 adult females presenting at the Service from January 2005 to December 2005.Three vaginal swabs were collected from each patient, one for wet mount microscopy, one for broth culture, and one for the molecular assay. Results The prevalence was 3.3% (culture, 3.1% (microscopy, 3.8% (PCR.An excess risk was detected in the immigrant population (risk ratio by PCR = 28. Conclusions The molecular approach was the most accurate way to detect the protozoon.The real-time PCR is convenient in a busy laboratory, provided the necessary equipment is available, and it is suitable for epidemiological investigation.

  10. Two, four, six, eight... stop and count before it is too late! An audit on swab, needle and instrument counts in theatre.

    LENUS (Irish Health Repository)

    Donnelly, T.

    2014-07-01

    A concurrent audit was conducted over a four week period to determine if the counting of swabs, needles and instruments for surgery adhered to local policy and recommended guidelines. Data were collected on 30 abdominal surgical procedures. This audit highlighted failings in the count process. It identified poor communication within the multidisciplinary team. There needs to be an increased awareness about local policy, national and international guidelines regarding the counting of swabs, needles and instruments for all surgical procedures.

  11. Chicken parvovirus viral loads in cloacal swabs from malabsorption syndrome-affected and healthy broilers.

    Science.gov (United States)

    Finkler, Fabrine; de Lima, Diane Alves; Cerva, Cristine; Cibulski, Samuel Paulo; Teixeira, Thais Fumaco; Dos Santos, Helton Fernandes; de Almeida, Laura Lopes; Roehe, Paulo Michel; Franco, Ana Cláudia

    2016-12-01

    Chicken parvovirus (ChPV) has been associated with malabsorption syndrome (MAS) in broilers. However, the participation of this virus in such syndrome is unclear, since it may be detected in diseased and healthy chickens. In the course of these studies, it was argued whether ChPV genome loads might be correlated to the occurrence of MAS. To check such a hypothesis, a SYBR green-based quantitative polymerase chain reaction was developed to detect and quantify ChPV genomes. Cloacal swabs from 68 broilers with MAS and 59 from healthy animals were collected from different poultry farms. Genomes of ChPV were detected in all samples, regardless of their health status. However, viral genome loads in MAS-affected broilers were significantly higher (1 × 10 5 genome copies per 100 ng DNA) than in healthy animals (1.3 × 10 3 GC/100 ng DNA). These findings indicate that there is an association between high ChPV genome loads and the occurrence of MAS in broilers.

  12. Financial management skills are associated with food insecurity in a sample of households with children in the United States.

    Science.gov (United States)

    Gundersen, Craig G; Garasky, Steven B

    2012-10-01

    Food insecurity is one of the leading public health challenges facing children in the United States today. Reducing food insecurity and its attendant consequences requires an understanding of the determinants of food insecurity. Although previous work has greatly advanced our understanding of these determinants, the role of one of the oft-speculated important determinants of food insecurity, household financial management skills, has not been considered. To address this research lacuna, we use a recently conducted survey, the Survey of Household Finances and Childhood Obesity, that has information on specific financial management practices, impressions of financial management skills, and households' food insecurity. The sample included 904 households with children. Within this sample, 19.3% were food insecure and, for our central financial management skill variable, the mean value was 3.55 on a 5-point scale. Probit regression models estimated the probability of a household being food insecure as conditional on financial management skills and other covariates. We found a large and significant inverse relationship between a respondent's use of specific financial management practices and food insecurity and between a respondent's confidence in his or her financial management skills and food insecurity. That is, households with greater financial management abilities are less likely to be food insecure. This finding also holds when the sample is restricted to households with incomes <200% of the poverty line. These results suggest that improving households' financial management skills has the potential to reduce food insecurity in the United States.

  13. Sponge and skin excision sampling for recovery of Salmonella and Campylobacter from defeathered broiler carcasses

    Science.gov (United States)

    Introduction: Salmonella and Campylobacter contamination of broiler carcass skin increases during feather removal. There are several methods for sampling carcasses including sponging or swabbing of skin surface and skin excision. It is unclear whether sponge sampling is adequate to remove bacteria f...

  14. Inactivation of Geobacillus stearothermophilus in canned food and coconut milk samples by addition of enterocin AS-48.

    Science.gov (United States)

    Viedma, Pilar Martínez; Abriouel, Hikmate; Ben Omar, Nabil; López, Rosario Lucas; Valdivia, Eva; Gálvez, Antonio

    2009-05-01

    The cyclic bacteriocin enterocin AS-48 was tested on a cocktail of two Geobacillus stearothermophilus strains in canned food samples (corn and peas), and in coconut milk. AS-48 (7 microg/g) reduced viable cell counts below detection levels in samples from canned corn and peas stored at 45 degrees C for 30 days. In coconut milk, bacterial inactivation by AS-48 (1.75 microg/ml) was even faster. In all canned food and drink samples inoculated with intact G. stearothermophilus endospores, bacteriocin addition (1.75 microg per g or ml of food sample) rapidly reduced viable cell counts below detection levels and avoided regrowth during storage. After a short-time bacteriocin treatment of endospores, trypsin addition markedly increased G. stearothermophilus survival, supporting the effect of residual bacteriocin on the observed loss of viability for endospores. Results from this study support the potential of enterocin AS-48 as a biopreservative against G. stearothermophilus.

  15. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    Science.gov (United States)

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Are great apes able to reason from multi-item samples to populations of food items?

    Science.gov (United States)

    Eckert, Johanna; Rakoczy, Hannes; Call, Josep

    2017-10-01

    Inductive learning from limited observations is a cognitive capacity of fundamental importance. In humans, it is underwritten by our intuitive statistics, the ability to draw systematic inferences from populations to randomly drawn samples and vice versa. According to recent research in cognitive development, human intuitive statistics develops early in infancy. Recent work in comparative psychology has produced first evidence for analogous cognitive capacities in great apes who flexibly drew inferences from populations to samples. In the present study, we investigated whether great apes (Pongo abelii, Pan troglodytes, Pan paniscus, Gorilla gorilla) also draw inductive inferences in the opposite direction, from samples to populations. In two experiments, apes saw an experimenter randomly drawing one multi-item sample from each of two populations of food items. The populations differed in their proportion of preferred to neutral items (24:6 vs. 6:24) but apes saw only the distribution of food items in the samples that reflected the distribution of the respective populations (e.g., 4:1 vs. 1:4). Based on this observation they were then allowed to choose between the two populations. Results show that apes seemed to make inferences from samples to populations and thus chose the population from which the more favorable (4:1) sample was drawn in Experiment 1. In this experiment, the more attractive sample not only contained proportionally but also absolutely more preferred food items than the less attractive sample. Experiment 2, however, revealed that when absolute and relative frequencies were disentangled, apes performed at chance level. Whether these limitations in apes' performance reflect true limits of cognitive competence or merely performance limitations due to accessory task demands is still an open question. © 2017 Wiley Periodicals, Inc.

  17. PCR based diagnostic assay targeting the beta tubulin gene for the detection of Trichomonas vaginalis infection in vaginal swab samples of symptomatic and asymptomatic women in India

    Directory of Open Access Journals (Sweden)

    Surya Prakash Dwivedi

    2012-10-01

    Full Text Available Objective: To develop an in-house PCR based diagnostic assay for identification of strains isolated from symptomatic and asymptomatic subjects of India, targeting the 毬 -tubulin gene using specific primers. Methods: In the present study a primer set is designed to target a well-conserved region in the beta-tubulin gene of Trichomonas vaginalis (T. vaginalis. All strains of T. vaginalis were tested and successfully detected by PCR yielding a single predicted product of 198 bp in gel electrophoresis, while there was negative response with DNA from Giardia lamblia, Toxoplasma gondii, Leishmania donovani and Entamoeba histolytica. The sensitivity and specificity for a single T. vaginalis cell per PCR was achieved. Axenic Culture, performed with long term axenized T. vaginalis culture system, was routinely examined to identify T. vaginalis. Results: The PCR based investigations with 498 vaginal swab samples from women attending OPD clinics of Halberg Hospital Moradabad and Queen Mary ’s Hospital, Lucknow, India and 17 long term axenic cultures maintained at PGIMER, Chandigarh, India using primer set BTUB 1 & BTUB 2 showed sensitivity and specificity response of 98% and 100%, respectively, while wet preparation in clinically isolated samples responded up to 62.5%. The PCR product sequencing result of symptomatic strains (SS1 of T. vaginalis (744 bp long was submitted to NCBI (Accession No: JF513200. It shows maximum identity 98 % with XM_001284521 Trichomonas vaginalis G-3 beta-tubulin (btub putative partial mRNA. Conclusions: The data gathered in the present study entail that the diagnosis of T. vaginalis infection by PCR may be established as a sensitive and specific protocol, to be incorporated into a joint strategy for the screening of multiple STDs by employing molecular amplification technique. The merits and precautions of the protocol have been discussed.

  18. Detection and genetic characterization of foot‐and‐mouth disease viruses in samples from clinically healthy animals in endemic settings

    DEFF Research Database (Denmark)

    Jamal, Syed Muhammad; Ferrari, G.; Hussain, M.

    2012-01-01

    A total of 1501 oral swab samples from Pakistan, Afghanistan and Tajikistan were collected from clinically healthy animals between July 2008 and August 2009 and assayed for the presence of foot‐and‐mouth disease virus (FMDV) RNA. The oral swab samples from two (of four) live animal markets...... for FMDV. In the Landhi dairy colony, Pakistan, a cohort of 179 apparently healthy animals was studied. On their arrival within the colony, thirty‐nine (22%) of these animals were found positive for FMDV RNA (serotype A was identified), while 130 (72.6%) had antibodies to FMDV non‐structural proteins. Thus...

  19. Random or systematic sampling to detect a localised microbial contamination within a batch of food

    NARCIS (Netherlands)

    Jongenburger, I.; Reij, M.W.; Boer, E.P.J.; Gorris, L.G.M.; Zwietering, M.H.

    2011-01-01

    Pathogenic microorganisms are known to be distributed heterogeneously in food products that are solid, semi-solid or powdered, like for instance peanut butter, cereals, or powdered milk. This complicates effective detection of the pathogens by sampling. Two-class sampling plans, which are deployed

  20. A novel sample preparation method using rapid nonheated saponification method for the determination of cholesterol in emulsified foods.

    Science.gov (United States)

    Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man

    2012-10-01

    In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®

  1. Identification of rhabdoviral sequences in oropharyngeal swabs from German and Danish bats

    DEFF Research Database (Denmark)

    Fischer, Melina; Freuling, Conrad M.; Müller, Thomas

    2014-01-01

    Background: In the frame of active lyssavirus surveillance in bats, oropharyngeal swabs from German (N = 2297) and Danish (N = 134) insectivorous bats were investigated using a newly developed generic pan-lyssavirus real-time reverse transcriptase PCR (RT-qPCR).Findings: In total, 15 RT-qPCR posi...... bats. The results also prove that the novel generic pan-lyssavirus RT-qPCR offers a very broad detection range that allows the collection of further valuable data concerning the broad and complex diversity within the family Rhabdoviridae....

  2. Comparison of eight methods for the extraction of Bacillus atrophaeus spore DNA from eleven common interferents and a common swab.

    Directory of Open Access Journals (Sweden)

    Helen L Rose

    Full Text Available Eight DNA extraction products or methods (Applied Biosystems PrepFiler Forensic DNA Extraction Kit; Bio-Rad Instagene Only, Bio-Rad Instagene & Spin Column Purification; EpiCentre MasterPure DNA & RNA Kit; FujiFilm QuickGene Mini80; Idaho Technologies 1-2-3 Q-Flow Kit; MoBio UltraClean Microbial DNA Isolation Kit; Sigma Extract-N-Amp Plant and Seed Kit were adapted to facilitate extraction of DNA under BSL3 containment conditions. DNA was extracted from 12 common interferents or sample types, spiked with spores of Bacillus atropheaus. Resulting extracts were tested by real-time PCR. No one method was the best, in terms of DNA extraction, across all sample types. Statistical analysis indicated that the PrepFiler method was the best method from six dry powders (baking, biological washing, milk, plain flour, filler and talcum and one solid (Underarm deodorant, the UltraClean method was the best from four liquids (aftershave, cola, nutrient broth, vinegar, and the MasterPure method was the best from the swab sample type. The best overall method, in terms of DNA extraction, across all sample types evaluated was the UltraClean method.

  3. Food insecurity and mental health problems among a community sample of young adults.

    Science.gov (United States)

    Pryor, Laura; Lioret, Sandrine; van der Waerden, Judith; Fombonne, Éric; Falissard, Bruno; Melchior, Maria

    2016-08-01

    Food insecurity has been found to be related to anxiety and depression; however, the association with other psychiatric disorders, particularly among young adults, is not well known. We examined whether food insecurity is independently associated with four common mental health problems among a community sample of young adults in France. Data are from the TEMPO longitudinal cohort study. In 1991, participants' parents provided information on health and family socioeconomic characteristics. In 2011, participants' (18-35 years) reported food insecurity, mental health symptoms, and socioeconomic conditions (n = 1214). Mental health problems ascertained included major depressive episode, suicidal ideation, attention deficit and hyperactivity disorder, and substance abuse and/or dependence (nicotine, alcohol and cannabis). Cross-sectional associations between food insecurity and mental health problems were tested using modified Poisson regressions, weighted by inverse probability weights (IPW) of exposure. This makes food insecure and not food insecure participants comparable on all characteristics including socioeconomic factors and past mental health problems. 8.5 % of young adults were food insecure. In IPW-controlled analyses, food insecurity was associated with increased levels of depression (RR = 2.01, 95 % CI 1.01-4.02), suicidal ideation (RR = 3.23, 95 % CI 1.55-6.75) and substance use problems (RR = 1.68, 95 % CI 1.15-2.46). Food insecurity co-occurs with depression, suicidal ideation and substance use problems in young adulthood. Our findings suggest that reductions in food insecurity during this important life period may help prevent mental health problems. Policies aiming to alleviate food insecurity should also address individuals' psychiatric problems, to prevent a lifelong vicious circle of poor mental health and low socioeconomic attainment.

  4. Optimaliseren van het antibioticabeleid in Nederland. X. SWAB-richtlijn voor antimicrobiële therapie bij gecompliceerde urineweginfecties

    NARCIS (Netherlands)

    Geerlings, S. E.; van den Broek, P. J.; van Haarst, E. P.; Vleming, L. J.; van Haaren, K. M. A.; Janknegt, R.; Platenkamp, G. J.; Prins, J. M.

    2006-01-01

    The 'Stichting Werkgroep Antibioticabeleid' (SWAB; Dutch Working Party on Antibiotic Policy) has developed an evidence-based guideline for the empirical antimicrobial treatment of complicated urinary tract infections (UTIs) in hospitalised adult patients. The choice of treatment is based on recent

  5. Detection of equine herpesvirus in horses with idiopathic keratoconjunctivitis and comparison of three sampling techniques.

    Science.gov (United States)

    Hollingsworth, Steven R; Pusterla, Nicola; Kass, Philip H; Good, Kathryn L; Brault, Stephanie A; Maggs, David J

    2015-09-01

    To determine the role of equine herpesvirus (EHV) in idiopathic keratoconjunctivitis in horses and to determine whether sample collection method affects detection of EHV DNA by quantitative polymerase chain reaction (qPCR). Twelve horses with idiopathic keratoconjunctivitis and six horses without signs of ophthalmic disease. Conjunctival swabs, corneal scrapings, and conjunctival biopsies were collected from 18 horses: 12 clinical cases with idiopathic keratoconjunctivitis and six euthanized controls. In horses with both eyes involved, the samples were taken from the eye judged to be more severely affected. Samples were tested with qPCR for EHV-1, EHV-2, EHV-4, and EHV-5 DNA. Quantity of EHV DNA and viral replicative activity were compared between the two populations and among the different sampling techniques; relative sensitivities of the sampling techniques were determined. Prevalence of EHV DNA as assessed by qPCR did not differ significantly between control horses and those with idiopathic keratoconjunctivitis. Sampling by conjunctival swab was more likely to yield viral DNA as assessed by qPCR than was conjunctival biopsy. EHV-1 and EHV-4 DNA were not detected in either normal or IKC-affected horses; EHV-2 DNA was detected in two of 12 affected horses but not in normal horses. EHV-5 DNA was commonly found in ophthalmically normal horses and horses with idiopathic keratoconjunctivitis. Because EHV-5 DNA was commonly found in control horses and in horses with idiopathic keratoconjunctivitis, qPCR was not useful for the etiological diagnosis of equine keratoconjunctivitis. Conjunctival swabs were significantly better at obtaining viral DNA samples than conjunctival biopsy in horses in which EHV-5 DNA was found. © 2015 American College of Veterinary Ophthalmologists.

  6. Year-Round Prevalence of Norovirus in the Environment of Catering Companies without a Recently Reported Outbreak of Gastroenteritis▿

    Science.gov (United States)

    Boxman, Ingeborg L. A.; Verhoef, Linda; Dijkman, Remco; Hägele, Geke; te Loeke, Nathalie A. J. M.; Koopmans, Marion

    2011-01-01

    Food handlers play an important role in the transmission of norovirus (NoV) in food-borne outbreaks of gastroenteritis (GE). In a year-round prevalence study, the prevalence of NoV in catering companies without recently reported outbreaks of GE was investigated and compared to the observed prevalence in catering companies with recently reported outbreaks. Swab samples were collected from surfaces in the kitchens and (staff) bathrooms in 832 randomly chosen companies and analyzed for the presence of NoV RNA. In total, 42 (1.7%) out of 2,496 environmental swabs from 35 (4.2%) catering companies tested positive. In contrast, NoV was detected in 147 (39.7%) of the 370 samples for 44 (61.1%) of the 72 establishments associated with outbreaks of gastroenteritis. NoV-positive swabs were more frequently found in winter, in specific types of companies (elderly homes and lunchrooms), and in establishments with separate bathrooms for staff. We found a borderline association with population density but no relation to the number of employees. Sequence analysis showed that environmental strains were interspersed with strains found in outbreaks of illness in humans. Thus, the presence of NoV in catering companies seemed to mirror the presence in the population but was strongly increased when associated with food-borne GE. Swabs may therefore serve as a valuable tool in outbreak investigations for the identification of the causative agent, although results should be interpreted with care, taking into account all other epidemiological data. PMID:21378056

  7. Discovery of a novel Parvovirinae virus, porcine parvovirus 7, by metagenomic sequencing of porcine rectal swabs.

    Science.gov (United States)

    Palinski, Rachel M; Mitra, Namita; Hause, Ben M

    2016-08-01

    Parvoviruses are a diverse group of viruses containing some of the smallest known species that are capable of infecting a wide range of animals. Metagenomic sequencing of pooled rectal swabs from adult pigs identified a 4103-bp contig consisting of two major open reading frames encoding proteins of 672 and 469 amino acids (aa) in length. BLASTP analysis of the 672-aa protein found 42.4 % identity to fruit bat (Eidolon helvum) parvovirus 2 (EhPV2) and 37.9 % to turkey parvovirus (TuPV) TP1-2012/HUN NS1 proteins. The 469-aa protein had no significant similarity to known proteins. Genetic and phylogenetic analyses suggest that PPV7, EhPV2, and TuPV represent a novel genus in the family Parvoviridae. Quantitative PCR screening of 182 porcine diagnostic samples found a total of 16 positives (8.6 %). Together, these data suggest that PPV7 is a highly divergent novel parvovirus prevalent within the US swine.

  8. β-Cyclodextrin coated CdSe/ZnS quantum dots for vanillin sensoring in food samples.

    Science.gov (United States)

    Durán, Gema M; Contento, Ana M; Ríos, Ángel

    2015-01-01

    An optical sensor for vanillin in food samples using CdSe/ZnS quantum dots (QDs) modified with β-cyclodextrin (β-CD) was developed. This vanillin-sensor is based on the selective host-guest interaction between vanillin and β-cyclodextrin. The procedure for the synthesis of β-cyclodextrin-CdSe/ZnS (β-CD-CdSe/ZnS-QDs) complex was optimized, and its fluorescent characteristics are reported. It was found that the interaction between vanillin and β-CD-CdSe/ZnS-QDs complex produced the quenching of the original fluorescence of β-CD-CdSe/ZnS-QDs according to the Stern-Volmer equation. The mechanism of the interaction is discussed. The analytical potential of this sensoring system was demonstrated by the determination of vanillin in synthetic and food samples. The method was selective for vanillin, with a limit of detection of 0.99 µg mL(-1), and a reproducibility of 4.1% in terms of relative standard deviation (1.2% under repeatability conditions). Recovery values were in the 90-105% range for food samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Antimicrobial and antibiofilm effects of selected food preservatives against Salmonella spp. isolated from chicken samples.

    Science.gov (United States)

    Er, Buket; Demirhan, Burak; Onurdag, Fatma Kaynak; Ozgacar, Selda Özgen; Oktem, Aysel Bayhan

    2014-03-01

    Salmonella spp. are widespread foodborne pathogens that contaminate egg and poultry meats. Attachment, colonization, as well as biofilm formation capacity of Salmonella spp. on food and contact surfaces of food may cause continuous contamination. Biofilm may play a crucial role in the survival of salmonellae under unfavorable environmental conditions, such as in animal slaughterhouses and processing plants. This could serve as a reservoir compromising food safety and human health. Addition of antimicrobial preservatives extends shelf lives of food products, but even when products are supplemented with adequate amounts of preservatives, it is not always possible to inhibit the microorganisms in a biofilm community. In this study, our aims were i) to determine the minimum inhibitory concentrations (MIC) and minimum biofilm inhibitory concentrations (MBIC) of selected preservatives against planktonic and biofilm forms of Salmonella spp. isolated from chicken samples and Salmonella Typhimurium SL1344 standard strain, ii) to show the differences in the susceptibility patterns of same strains versus the planktonic and biofilm forms to the same preservative agent, and iii) to determine and compare antimicrobial and antibiofilm effects of selected food preservatives against Salmonella spp. For this purpose, Salmonella Typhimurium SL1344 standard strain and 4 Salmonella spp. strains isolated from chicken samples were used. Investigation of antimicrobial and antibiofilm effects of selected food preservatives against Salmonella spp. was done according to Clinical and Laboratory Standards Institute M100-S18 guidelines and BioTimer assay, respectively. As preservative agents, pure ciprofloxacin, sodium nitrite, potassium sorbate, sodium benzoate, methyl paraben, and propyl paraben were selected. As a result, it was determined that MBIC values are greater than the MIC values of the preservatives. This result verified the resistance seen in a biofilm community to food

  10. Clostridium difficile from food and surface samples in a Belgian nursing home: an unlikely source of contamination.

    Science.gov (United States)

    Rodriguez, C; Korsak, N; Taminiau, B; Avesani, V; Van Broeck, J; Brach, P; Delmée, M; Daube, G

    2015-04-01

    This study investigates the contamination of foods and surfaces with Clostridium difficile in a single nursing home. C. difficile PCR-ribotype 078 was found in one food sample and in none of the tested surfaces. These results indicate that food and surfaces are an unlikely source of C. difficile infection in this setting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Diagnosis of visceral Leishmaniasis in asymptomatic dogs by the KDNA PCR-hybridization assay using noninvasive samples

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Rodrigo Souza; Andrade, Antero Silva Ribeiro de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia], e-mail: rleite2005@gmail.com; Ferreira, Sydney de Almeida; Ituassu, Leonardo Trindade; Melo, Maria Norma de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Centro de Ciencias Biologicas. Dept. de Parasitologia], e-mail: saninoalmeida@gmail.com

    2009-07-01

    The visceral leishmaniasis (VL) in Brazil is caused by Leishmania (Leishmania) chagasi and the asymptomatic dogs may transmit the parasite to sand flies vectors. The VL epidemiological control in Brazil involves the elimination of seropositive dogs, insecticide treatment and systematic treatment of human cases. Therefore, the accurate diagnosis is important in order to avoid the disease transmission or unnecessary culling of dogs. Serological tests are used for screening of dogs. However, these techniques present limitations. The Polymerase Chain Reaction (PCR) is an attractive alternative to the diagnosis in this context; but non-invasive samplings have great importance because they are simpler, painless and less resisted by dog-owners. This study aimed at evaluating conjunctival swab (CS) for canine VL diagnosis. In this methodology a sterile cotton swab is used to sampling the dog conjunctiva in both eyes. Thirty asymptomatic seropositive dogs were used. The samples were analyzed by the kDNA PCR-hybridization procedure in which the PCR products are hybridized with cloned kDNA mini-circles labeled with {sup 32}P[]dCTP. In addition, blood (B) was collected from each animal. L. chagasi was identified in 90% of CS samples and 13,6% of B samples. The high sensitivity obtained with asymptomatic dogs, in which the diagnosis is more difficult due the low number of parasites in the samples, allow concluding that the conjunctival swab associated to the kDNA PCR-hybridization assay provides a valuable alternative tool for the direct diagnosis of canine leishmaniasis. (author)

  12. Field-Amplified Sample Injection-Micellar Electrokinetic Chromatography for the Determination of Benzophenones in Food Simulants

    Directory of Open Access Journals (Sweden)

    Cristina Félez

    2015-07-01

    Full Text Available A field-amplified sample injection-micellar electrokinetic chromatography (FASI-MEKC method for the determination of 14 benzophenones (BPs in a food simulant used in migration studies of food packaging materials was developed, allowing almost baseline separation in less than 21 min. The use of a 10 mM sodium dodecyl sulfate (SDS solution as sample matrix was mandatory to achieve FASI enhancement of the analyzed BPs. A 21- to 784-fold sensitivity enhancement was achieved with FASI-MEKC, obtaining limits of detection down to 5.1–68.4 µg/L, with acceptable run-to-run precisions (RSD values lower than 22.3% and accuracy (relative errors lower than 21.0%. Method performance was evaluated by quantifying BPs in the food simulant spiked at 500 µg/L (bellow the established specific migration limit for BP (600 µg/L by EU legislation. For a 95% confidence level, no statistical differences were observed between found and spiked concentrations (probability at the confidence level, p value, of 0.55, showing that the proposed FASI-MEKC method is suitable for the analysis of BPs in food packaging migration studies at the levels established by EU legislation.

  13. Interferences in radioimmunoassay of aflatoxins in food and fodder samples of plant origin

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Brezina, P.; Kas, J.

    1988-01-01

    Cross-reactions and resulting nonspecific binding of substances with structures resembling aflatoxins (derivatives of coumarin, and cinnamonic and benzoic acids, etc.) were investigated. The concentrations of these substances causing erroneously high or false positive values in radioimmunoassay were determined. One μg aflatoxin B 1 /kg sample may be simulated by the occurrence of 5 g coumarin, 10 g caffeic acid, 16 g chlorogenic acid, or 15 g vanillin/kg fodder or food sample

  14. The Presence of Norovirus and Adenovirus on Environmental Surfaces in Relation to the Hygienic Level in Food Service Operations Associated with a Suspected Gastroenteritis Outbreak.

    Science.gov (United States)

    Maunula, Leena; Rönnqvist, M; Åberg, R; Lunden, J; Nevas, M

    2017-09-01

    Norovirus (NoV) gastroenteritis outbreaks appear frequently in food service operations (FSOs), such as in restaurants and canteens. In this study the presence of NoV and adenovirus (AdV) genomes was investigated on the surfaces of premises, especially in kitchens, of 30 FSOs where foodborne gastroenteritis outbreaks were suspected. The objective was to establish a possible association between the presence of virus genomes on surfaces and a visual hygienic status of the FSOs. NoV genome was found in 11 and AdV genome in 8 out of 30 FSOs. In total, 291 swabs were taken, of which 8.9% contained NoV and 5.8% AdV genome. The presence of NoV genomes on the surfaces was not found to associate with lower hygiene level of the premises when based on visual inspection; most (7/9) of the FSOs with NoV contamination on surfaces and a completed evaluation form had a good hygiene level (the best category). Restaurants had a significantly lower proportion of NoV-positive swabs compared to other FSOs (canteens, cafeteria, schools etc.) taken together (p = 0.00014). The presence of a designated break room for the workers was found to be significantly more common in AdV-negative kitchens (p = 0.046). Our findings suggest that swabbing is necessary for revealing viral contamination of surfaces and emphasis of hygiene inspections should be on the food handling procedures, and the education of food workers on virus transmission.

  15. Validation of a modification to Performance-Tested Method 010403: microwell DNA hybridization assay for detection of Listeria spp. in selected foods and selected environmental surfaces.

    Science.gov (United States)

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false

  16. Flocked nylon swabs versus RODAC plates for detection of multidrug-resistant organisms on environmental surfaces in intensive care units.

    Science.gov (United States)

    Okamoto, K; Rhee, Y; Schoeny, M; Lolans, K; Cheng, J; Reddy, S; Weinstein, R A; Hayden, M K; Popovich, K J

    2018-01-01

    To compare two culture methods [nylon fiber flocked swabs with broth enrichment versus RODAC ('replicate organism detection and counting') plates] for recovery of multidrug-resistant organisms, 780 environmental surfaces in 63 rooms of patients on contact precautions in four intensive care units at one hospital were examined. Among sites that had at least one positive culture, swab culture with broth enrichment detected the target organisms more frequently than RODAC plates (37.5% vs 26.0%, P = 0.06). There was moderate agreement between the two methods (κ = 0.44) with agreement better for small or flat surfaces compared to large or irregular surfaces. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Molecular, Serological And Microbiological Profiling Evidence Of ...

    African Journals Online (AJOL)

    All items that the boy had contact with including a laboratory coat, bunch of keys and shoes were swabbed. Finally samples of all the boy's food and drinks were taken. Microbiological, Serological and Polymerase Chain Reaction (PCR) Profiling Assays. l the samples were cultured on Sorbitol - MacConkey (SMAC) agar, ...

  18. Direct impression on agar surface as a diagnostic sampling procedure for candida balanitis.

    Science.gov (United States)

    Lisboa, Carmen; Santos, António; Azevedo, Filomena; Pina-Vaz, Cidália; Rodrigues, Acácio Gonçalves

    2010-02-01

    The diagnosis of candida balanitis should be based upon both clinical and mycological data. The procedure of material collection is a critical issue to confirm or rule out the clinical diagnosis of candida balanitis. To compare direct impression of the glans on the agar surface of solid culture media with the collection of genital exudates with cotton swab for the diagnosis of candida balanitis. A prospective cross-sectional study was carried out during a 36-month period. Sexually transmitted disease clinic attendees with balanitis and asymptomatic men were included. Specimens for yeast culture were collected from the glans penis and inner preputial layer using the direct impression on CHROMagar candida medium and by swabbing with a sterile cotton swab. Among 478 men enrolled, 189 had balanitis. The prevalence of candida balanitis was 17.8% (85/478) confirmed after culture by direct impression; the swab method detected only 54/85 (63.5%) of these men. Of the 289 asymptomatic men, 36 (12.5%) yielded Candida spp; the swab method detected only 38.9% of these men. The risk of having candida balanitis is 8.9 (IC 95% 2.48 to 32.04) whenever the number of candida colonies recovered by direct impression was greater than 10. Direct impression on CHROMagar candida medium resulted in the highest Candida spp recovery rate. More than 10 colonies yielded by impression culture were statistically associated with candida balanitis. This method shows the ideal profile for sampling the male genital area for yeasts and should be included in the management of balanitis.

  19. Simultaneous Detection of Four Foodborne Viruses in Food Samples Using a One-Step Multiplex Reverse Transcription PCR.

    Science.gov (United States)

    Lee, Shin-Young; Kim, Mi-Ju; Kim, Hyun-Joong; Jeong, KwangCheol Casey; Kim, Hae-Yeong

    2018-02-28

    A one-step multiplex reverse transcription PCR (RT-PCR) method comprising six primer sets (for the detection of norovirus GI and GII, hepatitis A virus, rotavirus, and astrovirus) was developed to simultaneously detect four kinds of pathogenic viruses. The size of the PCR products for norovirus GI and GII, hepatitis A virus (VP3/VP1 and P2A regions), rotavirus, and astrovirus were 330, 164, 244, 198, 629, and 449 bp, respectively. The RT-PCR with the six primer sets showed specificity for the pathogenic viruses. The detection limit of the developed multiplex RT-PCR, as evaluated using serially diluted viral RNAs, was comparable to that of one-step single RT-PCR. Moreover, this multiplex RT-PCR was evaluated using food samples such as water, oysters, lettuce, and vegetable product. These food samples were artificially spiked with the four kinds of viruses in diverse combinations, and the spiked viruses in all food samples were detected successfully.

  20. Advantages and Limitations of Direct PCR Amplification of Bacterial 16S-rDNA from Resected Heart Tissue or Swabs Followed by Direct Sequencing for Diagnosing Infective Endocarditis: A Retrospective Analysis in the Routine Clinical Setting.

    Science.gov (United States)

    Maneg, Daniela; Sponsel, Janina; Müller, Iris; Lohr, Benedikt; Penders, John; Madlener, Katharina; Hunfeld, Klaus-Peter

    2016-01-01

    Infective endocarditis (IE) is a life-threatening disease that is associated with high morbidity and mortality. Its long-term prognosis strongly depends on a timely and optimized antibiotic treatment. Therefore, identification of the causative pathogen is crucial and currently based on blood cultures followed by characterization and susceptibility testing of the isolate. However, antibiotic treatment starting prior to blood sampling or IE caused by fastidious or intracellular microorganisms may cause negative culture results. Here we investigate the additional diagnostic value of broad-range PCR in combination with direct sequencing on resected heart tissue or swabs in patients with tissue or swab culture-negative IE in a routine clinical setting. Sensitivity, specificity, and positive and negative predictive values of broad-range PCR from diagnostic material in our patients were 33.3%, 76.9%, 90.9%, and 14.3%, respectively. We identified a total of 20 patients (21.5%) with tissue or culture-negative IE who profited by the additional application of broad-range PCR. We conclude that broad-range PCR on resected heart tissue or swabs is an important complementary diagnostic approach. It should be seen as an indispensable new tool for both the therapeutic and diagnostic management of culture-negative IE and we thus propose its possible inclusion in Duke's diagnostic classification scheme.

  1. Techniques for the detection of pathogenic Cryptococcus species in wood decay substrata and the evaluation of viability in stored samples

    Directory of Open Access Journals (Sweden)

    Christian Alvarez

    2013-02-01

    Full Text Available In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA plates. The conventional technique (CT yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1] compared to the humid swab technique (ST. However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

  2. Listeria monocytogenes contamination of the environment and surfaces of the equipment in the meat processing facilities in republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Dean Jankuloski

    2007-11-01

    Full Text Available Listeria monocytogenes contamination of the environment and surfaces of the equipment was examined in seven meat processing facilities. Up to date prevalence of this foodborn pathogen in meat processing facilities facilities in Republic of Macedonia was unknown. Biofilms are composed from food spoilage microorganisms and food born pathogens. They are located on the surfaces of the equipment that come in contact with food and in facilities environment. Microorganisms in biofilm presenting micro eco system and are source of dissemination and contamination of food born pathogens in final meat products. During the preparation of this study we have covered a 7 meat processing facilities and we took a total of 39 swabs from surfaces that come in direct or indirect contact with food. Listeria monocytogenes was discovered in 10 (25,64% swabs (locations. Prevalence of other Listeria spp. compared with total number of taken samples was 15 (38,46% Listeria innocua, 3 (7,69% Listeria welshimeri and 1 (2,65% isolate Listeria seeligeri.

  3. Detection of Mycoplasma synoviae in clinical samples by VlhA-PCR method

    Directory of Open Access Journals (Sweden)

    H Ansari

    2010-02-01

    Full Text Available As one of the major pathogens of avian species, Mycoplasma Synoviae causes significant economic losses to the poultry industry. The main purpose of this study was to detect Mycoplasma Synoviae in clinical samples using the VlhA-PCR method. For serological screening test, 373 serum samples were collected from 25 breeder farms and rapid serum agglutination test conducted which revealed that 143 samples equivalent to 19 breeder farms were positive. For VlhA-PCR assay, 20 of the previously mentioned breeder farms were selected and sterile swab were collected from the palatine cleft, trachea, air sacs and lungs. Three swabs from 3 birds were placed in a test tube containing 1 ml of PBS and transferred to the laboratory for PCR test. Specific primers for VIhA gene were employed in this study. The PCR product from specific primers showed 350-400 bp for all field isolated on electrophoresis gel in 8 farms. VlhA-PCR with high sensitivity could be employed in definitive diagnosis of Mycoplasma Synoviae infection in the laboratory.

  4. Food insecurity and mental disorders in a national sample of U.S. adolescents.

    Science.gov (United States)

    McLaughlin, Katie A; Green, Jennifer Greif; Alegría, Margarita; Jane Costello, E; Gruber, Michael J; Sampson, Nancy A; Kessler, Ronald C

    2012-12-01

    To examine whether food insecurity is associated with past-year DSM-IV mental disorders after controlling for standard indicators of family socioeconomic status (SES) in a U.S. national sample of adolescents. Data were drawn from 6,483 adolescent-parent pairs who participated in the National Comorbidity Survey Replication Adolescent Supplement, a national survey of adolescents 13 to 17 years old. Frequency and severity of food insecurity were assessed with questions based on the U.S. Department of Agriculture's Food Security Scale (standardized to a mean of 0, variance of 1). DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview. Associations of food insecurity with DSM-IV/Composite International Diagnostic Interview diagnoses were estimated with logistic regression models controlling for family SES (parental education, household income, relative deprivation, community-level inequality, and subjective social status). Food insecurity was highest in adolescents with the lowest SES. Controlling simultaneously for other aspects of SES, standardized food insecurity was associated with an increased odds of past-year mood, anxiety, behavior, and substance disorders. A 1 standard deviation increase in food insecurity was associated with a 14% increase in the odds of past-year mental disorder, even after controlling for extreme poverty. The association between food insecurity and mood disorders was strongest in adolescents living in families with a low household income and high relative deprivation. Food insecurity is associated with a wide range of adolescent mental disorders independently of other aspects of SES. Expansion of social programs aimed at decreasing family economic strain might be one useful policy approach for improving youth mental health. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  5. Optimaliseren van het antibioticabeleid in Nederland. IX. SWAB-richtlijn voor antimicrobiële therapie bij acute infectieuze diarree

    NARCIS (Netherlands)

    Bos, J. C.; Schultsz, C.; Vandenbroucke-Grauls, C. M. J.; Speelman, P.; Prins, J. M.

    2006-01-01

    The 'Stichting Werkgroep Antibioticabeleid' (SWAB; Dutch Working Party on Antibiotic Policy) develops evidence-based guidelines for the use of antibiotics in hospitalised adults. This guideline on acute infectious diarrhoea (AID) concerns the antibiotic treatment of acute infectious inflammation of

  6. Obesity and household food insecurity: evidence from a sample of rural households in Malaysia.

    Science.gov (United States)

    Shariff, Z Mohd; Khor, G L

    2005-09-01

    The study examined nutritional outcomes related to body fat accumulation of food insecurity among women from selected rural communities in Malaysia. Cross-sectional study. Rural communities (seven villages and two palm plantations) in a district with high percentage of welfare recipients. Malay (n = 140) and Indian (n = 60) women were interviewed and measured for demographic, socioeconomic, anthropometric, dietary and physical activity information. The women were measured for their body mass index and waist circumference (WC). Energy and nutrient intakes, food group intake and food variety score were analyzed from 24 h dietary recalls and food-frequency questionnaire. Daily physical activity of the women was examined as the number of hours spent in economic, domestic, leisure and sport activities. Using the Radimer/Cornell Hunger and Food Insecurity Instrument, 58% of the women reported some degree of food insecurity (household insecure 14%, adult insecure 9.5% and child hunger 34.5%). In general, food-insecure women had lower years of education, household income and income per capita, more children and mothers as housewives. More than 50% of food-insecure women were overweight and obese than women from food-secure households (38%). Similarly, more food-insecure women (32-47%) had at-risk WC (> or = 88 cm) than food-secure women (29%). Food-insecure women spent significantly more time in domestic and leisure activities than food-secure women. Overweight and abdominal adiposity among the women were associated with a number of independent variables, such as women as housewives, women with more children, larger household size, food insecurity, shorter time spent in economic activities, longer time spent in leisure activities and lower food variety score. After adjusting for factors that are related to both adiposity and food insecurity, women from food-insecure households were significantly more likely to have at-risk WC, but not obese. Among this sample of rural

  7. INDUÇÃO DE OVULAÇÃO COM SWAB VAGINAL EM GATAS DOMÉSTICAS E SEUS EFEITOS SOBRE A MORFOLOGIA UTERINA

    OpenAIRE

    Silva, Sandra Cristina Becker; Silva, Maíra Corona da; Silva, Fabiana Lessa; Snoeck, Paola Pereira das Neves

    2017-01-01

    Resumo A ovulação em gatas é induzida por um reflexo neuroendócrino atribuído à estimulação mecânica dos receptores sensoriais durante o coito. Esta estimulação pode ser simulada com auxílio do swab vaginal, desencadeando a pseudogestação. Objetivou-se verificar a eficiência da indução de ovulação com swab, a fim de estabelecer um tratamento contraceptivo natural para felinos domésticos, bem como os efeitos sobre o útero do uso repetido dessa técnica. Na primeira fase do trabalho, foram avali...

  8. The use of coroner's autopsy reports to validate the use of targeted swabbing rather than tissue collection for rapid confirmation of virological causes of sudden death in the community.

    Science.gov (United States)

    Moore, Catherine; Jones, Rachel

    2015-02-01

    In this study, coroner's autopsy reports were used to validate results obtained from respiratory virus screening of swabs rather than tissue collected during autopsy in cases of adult death of unknown cause. Coroner's autopsy samples collected for respiratory virus screening between October 2010 and February 2011, were identified. Autopsy reports were requested from cases positive for a virus. Each report was reviewed to correlate findings at autopsy with the virology result and to determine whether the virus found was listed as a contributing factor in the death. Sixty-four coroner's autopsy cases were identified and a respiratory virus was found in 25 cases. Influenza A(H1N1)pdm09 virus was found most frequently, then RSV and influenza B with a dual influenza A and B infection and a parainfluenza type 1. Where multiple sites were swabbed, the virus was detected in all sites. Autopsy reports for 12 cases were obtained each reporting findings consistent with respiratory infection. Influenza A was always listed as a contributing factor in the death whereas RSV was listed once and influenza B was omitted in one case. The quality of the reports was variable and full histology was less likely to be performed in the elderly. While coroner's reports supported the use of swabbing rather than tissue collection, the lack of consistency and omission of the virology findings as contributing factors to death means that the burden of viruses on mortality statistics will remain under-estimated particularly in the elderly. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Method Comparison of Neutron Activation Analysis and Atomic Absorption Spectrometry for Determination of Zinc in Food Samples

    International Nuclear Information System (INIS)

    Endah Damastuti; Syukria Kurniawati; Natalia Adventini

    2009-01-01

    Zinc as a micro nutrient, has important roles in human metabolism system. It is required by the body in appropriate amount from food intake. Due to the very low concentration of Zinc in food, high selectivity and sensitivity analysis technique is required for the determination, such as Neutron Activation Analysis (NAA) and Atomic Absorption Spectrometry (AAS). In this experiment, both methods were compared in zinc analysis of food samples. The subject of this experiment is to examine of those methods conformity and improving the technique capability in zinc analysis in food sample. Those methods were validated by analyzing zinc in SRM NIST 1548a Typical Diet and were tested its accuracy and precision. The results of Zn concentration were 25.1 ± 2.14 mg/kg by NAA and 24.1 ± 1.40 mg/kg by AAS while the certificate value was 24.6 ± 1.80 mg/kg. Percentage of relative bias, %CV, μ-test score and HORRAT(Horwitz ratio) value given by NAA were 2%, 8.5%, 0.18 and 0.9 respectively, while %relative bias, %CV, μ-test score and HORRAT value given by AAS were 2%, 5.8 %, 0.20 and 0.6 respectively. The result obtained for Zn concentration in various food samples by NAA and AAS were varied from 13.7 – 29.3 mg/kg with mean value 19.8 mg/kg and 11.2 – 26.0 mg/kg with mean value 17.3 mg/kg (author)

  10. Food Insecurity and Mental Disorders in a National Sample of U.S. Adolescents

    Science.gov (United States)

    McLaughlin, Katie A.; Green, Jennifer Greif; Alegria, Margarita; Costello, E. Jane; Gruber, Michael J.; Sampson, Nancy A.; Kessler, Ronald C.

    2012-01-01

    Objective: To examine whether food insecurity is associated with past-year "DSM-IV" mental disorders after controlling for standard indicators of family socioeconomic status (SES) in a U.S. national sample of adolescents. Method: Data were drawn from 6,483 adolescent-parent pairs who participated in the National Comorbidity Survey Replication…

  11. Pseudo-outbreak of Cupriavidus pauculus infection at an outpatient clinic related to rinsing culturette swabs in tap water.

    Science.gov (United States)

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-07-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.

  12. Pseudo-Outbreak of Cupriavidus pauculus Infection at an Outpatient Clinic Related to Rinsing Culturette Swabs in Tap Water▿

    OpenAIRE

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-01-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.

  13. Biological Agent Sample Preparation for the Detection and Identification of Multiple Agents by Nucleic Acid-Based Analysis

    National Research Council Canada - National Science Library

    Fields, Robert

    2002-01-01

    .... The AutoLyser instrument which we have developed, provides fully automated purification of viral, bacterial and human genomic DNA and RNA from clinical samples, cell culture and swabs in as little...

  14. Radiation traces in exportation food samples of Parana State, Brazil

    International Nuclear Information System (INIS)

    Scheibel, Viviane

    2002-02-01

    This work deals with radioactive traces measurements in foodstuffs produced at the State of Parana, with large export rate and also of nutritious products of some regional trading companies. The measured foods were: sulfite treated sugar, tea, mint candy, soy in grain, soy crumb, gross soy oil, gum free oil and commercial refined soy oil. Six samples of each lot of the analyzed material were prepared, which represent a sampling with 90% of confidence. The samples were sealed in Marinelli beaker of 2.1 L completely filled and kept during 40 days until secular equilibrium was achieved. The counting time for each measure was of 48 hours. Measurements were carried out by gamma-ray spectrometry employing a HPGe detector with 10% of relative efficiency, coupled to standard nuclear electronics and a 8 l multichannel card. The acquisition of the data was accomplished with the software Maestro TM , version 3.2. The energy resolution of the 137 Cs 661.62 keV gamma line was 1.75 keV. The larger intensity gamma lines observed in the spectra were from the following radionuclides: 228 Ac, 208 Tl, 212 Pb of the 232 Th series, 214 Bi and 214 Pb from the 238 U series, 227 Ac from the 235 U series and 40 K. Activities and lower level of detection limits were calculated according to the International Agency of Atomic Energy norms.The detector efficiency was measured using a 152 Eu certified source and IAEA-375 and IAEA-326 certified reference materials. For most of the radionuclides it was possible only the measurement of the minimum activity detectable in the foodstuffs. Self-attenuation corrections were accomplished with support literature results. The most important activity observed was that of 40 K, whose value measured for soy in natura was 745.0 + - 9 .1 Bq/kg and for the crumb soy 1473 ± 15 Bq/kg.. he measured activities of the several analyzed foods were compatible with the values expected for non contaminated normal environmental samples, except for soy crumb, whose 40 K

  15. Criteria to define a more relevant reference sample of titanium dioxide in the context of food: a multiscale approach.

    Science.gov (United States)

    Dudefoi, William; Terrisse, Hélène; Richard-Plouet, Mireille; Gautron, Eric; Popa, Florin; Humbert, Bernard; Ropers, Marie-Hélène

    2017-05-01

    Titanium dioxide (TiO 2 ) is a transition metal oxide widely used as a white pigment in various applications, including food. Due to the classification of TiO 2 nanoparticles by the International Agency for Research on Cancer as potentially harmful for humans by inhalation, the presence of nanoparticles in food products needed to be confirmed by a set of independent studies. Seven samples of food-grade TiO 2 (E171) were extensively characterised for their size distribution, crystallinity and surface properties by the currently recommended methods. All investigated E171 samples contained a fraction of nanoparticles, however, below the threshold defining the labelling of nanomaterial. On the basis of these results and a statistical analysis, E171 food-grade TiO 2 totally differs from the reference material P25, confirming the few published data on this kind of particle. Therefore, the reference material P25 does not appear to be the most suitable model to study the fate of food-grade TiO 2 in the gastrointestinal tract. The criteria currently to obtain a representative food-grade sample of TiO 2 are the following: (1) crystalline-phase anatase, (2) a powder with an isoelectric point very close to 4.1, (3) a fraction of nanoparticles comprised between 15% and 45%, and (4) a low specific surface area around 10 m 2  g - 1 .

  16. Pseudo-Outbreak of Cupriavidus pauculus Infection at an Outpatient Clinic Related to Rinsing Culturette Swabs in Tap Water▿

    Science.gov (United States)

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-01-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen. PMID:20444965

  17. Detection of mycoplasmas in urethral swabs from HIV-1 infected patients and control individuals using culture techniques and polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    CUNHA Regina Ayr Florio da

    1998-01-01

    Full Text Available The objective of the present study was to determine the prevalence of certain mycoplasma species, i.e., Mycoplasma hominis, Ureaplasma urealyticum and Mycoplasma penetrans, in urethral swabs from HIV-1 infected patients compared to swabs from a control group. Mycoplasmas were detected by routine culture techniques and by the Polymerase Chain Reaction (PCR technique, using 16SrRNA generic primers of conserved region and Mycoplasma penetrans specific primers. The positivity rates obtained with the two methods were comparable. Nevertheless, PCR was more sensitive, while the culture techniques allowed the quantification of the isolates. The results showed no significant difference (p < 0.05 in positivity rates between the methods used for mycoplasma detection.

  18. Detection of Listeria monocytogenes in ready-to-eat foods sampled from a catering service in Apulia, Italy.

    Science.gov (United States)

    Caggiano, Giuseppina; De Giglio, Osvalda; Lovero, Grazia; Rutigliano, Serafina; Diella, Giusy; Balbino, Stella; Napoli, Christian; Montagna, Maria Teresa

    2015-01-01

    Listeria monocytogenes is currently considered a relevant emerging food-borne pathogen. In particular, the European Centre for Disease Prevention and Control (ECDC) illustrates its widespread presence in different foods. In the present article, L. monocytogenes prevalence was estimated in cooked ready-to-eat foods sampled from a catering service in a Apulia city, southern Italy. The study was carried out from January to June 2014 in according to Regulation (EC) No. 852/2004, and ISO 11290-1:1996/Amd.1:2004 methods. Listeria spp. was isolated in 8.3% of the samples: L. monocytogenes was identified with the highest prevalence in potato gateau (66.6%), followed by rice dishes (11.1%), Listeria innocua was isolated from potato purea (11.1%) and cooked vegetables (11.1%). These preliminary results confirm the diffusion of the microorganism in ready-to-eat products; therefore, strategies aimed at protecting the consumers should be adopted. First of all, correct hygiene procedures should be followed and then microbiological tests should be implemented in order to early detect Listeria spp. (not only LM) contamination in cooked foods.

  19. Evaluation of a nested PCR test and bacterial culture of swabs from the nasal passages and from abscesses in relation to diagnosis of Streptococcus equi infection (strangles)

    DEFF Research Database (Denmark)

    Grønbæk, L.M.; Angen, Øystein; Vigre, Håkan

    2006-01-01

    . Methods: Two herds with natural outbreaks of strangles were visited over a period of 15 weeks and 323 samples originating from 35 horses investigated. The diagnostic use of a nested PCR test was evaluated using a collection of 165 isolates of Lancefield group C streptococci (species specificity) and swabs...... from nasal passages or from abscesses from horses infected with S. equi (diagnostic sensitivity). Results: All 45 S. equi isolates tested positive in the nested PCR, whereas no amplicon was formed when testing the other 120 Lancefield group C isolates. A total of 43 samples were collected from 11...... horses with and without clinical signs. Conclusions and potential relevance: The nested PCR test represents a species-specific and -sensitive method for diagnosis of S. equi from clinical samples. It may, however, be desirable in future to develop detection methods with high diagnostic sensitivity...

  20. Study of Cs/sup 137/ contamination in soil and food samples of Jhangar valley, Pakistan

    International Nuclear Information System (INIS)

    Chaudhry, Z.S.; Khan, H.M.; Aslam, M.; Iqbal, S.; Orfi, S.D.

    2001-01-01

    Chernobyl accident has been the main source of artificial radioactive contamination throughout the world and its effects have been found in Pakistan as well. In the present study, activities of an important anthropogenic radionuclide, Cs/sup 137/ in soil and food samples of Jhangar Valley of Pakistan have been determined using PC based gamma spectrometer. Soil-375 from IAEA was used as reference material. The soil samples were collected from the agricultural fields of the selected area while food samples, grown in the selected area, were collected from the fields or from local market. After proper treatment, the samples were analyzed using a high purity germanium (HPGe) detector. The following values for average specific activity of Cs/sup 137/ were found: soil (range 1.3-46.8 Bq/kg) (12.0 Bq/kg), wheat (0.9 +- 0.05 Bq/kg), millet (1.5 +- 0.06 Bq/kg), lentils (2.0 +- 0.1 Bq/kg), potato (0.6 +- 0.03 Bq/kg) and cauliflower (0.6 +- 0.03 Bq/kg). The results have been discussed and compared with other data available in the literature. (author)

  1. Simultaneous differential detection of Chlamydophila abortus, Chlamydophila pecorum and Coxiella burnetii from aborted ruminant's clinical samples using multiplex PCR

    Directory of Open Access Journals (Sweden)

    Rodolakis Annie

    2009-07-01

    Full Text Available Abstract Background Chlamydiosis and Q fever, two zoonosis, are important causes of ruminants' abortion around the world. They are caused respectively by strictly intracellular and Gram negative bacterium Chlamydophila abortus (Cp. abortus and Coxiella burnetii (C. burnetii. Chlamydophila pecorum (Cp. pecorum is commonly isolated from the digestive tract of clinically inconspicuous ruminants but the abortive and zoonotic impact of this bacterium is still unknown because Cp. pecorum is rarely suspected in abortion cases of small ruminants. We have developed a multiplex PCR (m-PCR for rapid simultaneous differential detection of Cp. abortus, Cp. pecorum and C. burnetii in clinical samples taken from infected animals. Results Specific PCR primers were designed and a sensitive and specific m-PCR was developed to detect simultaneously, in one tube reaction, three specific fragments of 821, 526 and 687-bp long for Cp. abortus, Cp. pecorum and C. burnetii respectively. This m-PCR assay was performed on 253 clinical samples taken from infected ruminant's flocks that have showed problems of abortion diseases. Thus, 67 samples were infected by either one of the three pathogens: 16 (13 vaginal swabs and 3 placentas were positive for Cp. abortus, 2 were positive for Cp. pecorum (1 vaginal swab and 1 placenta and 49 samples (33 vaginal swabs, 11 raw milks, 4 faeces and 1 placenta were positive for C. burnetii. Two vaginal swabs were m-PCR positive of both Cp. abortus and C. burnetii and none of the tested samples was shown to be infected simultaneously with the three pathogens. Conclusion We have successfully developed a rapid multiplex PCR that can detect and differentiate Cp. abortus, Cp. pecorum and C. burnetii; with a good sensitivity and specificity. The diagnosis of chlamydiosis and Q fever may be greatly simplified and performed at low cost. In addition, the improvement in diagnostic techniques will enhance our knowledge regarding the prevalence and

  2. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    Science.gov (United States)

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  3. Molecular characterization of diarrheagenic Escherichia coli strains from stools samples and food products in Colombia

    OpenAIRE

    Rúgeles, Laura Cristina; Bai, Jing; Martínez, Aída Juliana; Vanegas, María Consuelo; Gómez-Duarte, Oscar Gilberto

    2010-01-01

    The prevalence of diarrheagenic E. coli in childhood diarrhea and the role of contaminated food products in disease transmission in Colombia are largely unknown. The aim of this study is to identify E. coli pathotypes, including E. coli O157:H7, from 108 stool samples from children with acute diarrhea, 38 meat samples and 38 vegetable samples. Multiplex PCR and Bax Dupont systems were used for E. coli pathotype detection. Eighteen (9.8%) E. coli diarrheagenic pathotypes were detected among al...

  4. Advantages and Limitations of Direct PCR Amplification of Bacterial 16S-rDNA from Resected Heart Tissue or Swabs Followed by Direct Sequencing for Diagnosing Infective Endocarditis: A Retrospective Analysis in the Routine Clinical Setting

    Directory of Open Access Journals (Sweden)

    Daniela Maneg

    2016-01-01

    Full Text Available Infective endocarditis (IE is a life-threatening disease that is associated with high morbidity and mortality. Its long-term prognosis strongly depends on a timely and optimized antibiotic treatment. Therefore, identification of the causative pathogen is crucial and currently based on blood cultures followed by characterization and susceptibility testing of the isolate. However, antibiotic treatment starting prior to blood sampling or IE caused by fastidious or intracellular microorganisms may cause negative culture results. Here we investigate the additional diagnostic value of broad-range PCR in combination with direct sequencing on resected heart tissue or swabs in patients with tissue or swab culture-negative IE in a routine clinical setting. Sensitivity, specificity, and positive and negative predictive values of broad-range PCR from diagnostic material in our patients were 33.3%, 76.9%, 90.9%, and 14.3%, respectively. We identified a total of 20 patients (21.5% with tissue or culture-negative IE who profited by the additional application of broad-range PCR. We conclude that broad-range PCR on resected heart tissue or swabs is an important complementary diagnostic approach. It should be seen as an indispensable new tool for both the therapeutic and diagnostic management of culture-negative IE and we thus propose its possible inclusion in Duke’s diagnostic classification scheme.

  5. Sample preparation for avian and porcine influenza virus cDNA amplification simplified: Boilign vs. conventional RNA extraction

    International Nuclear Information System (INIS)

    Fereidouni, S.R.; Starick, E.; Ziller, M.; Harder, T.C.; Unger, H.; Hamilton, K.; Globig, A.

    2016-01-01

    Full text: RNA extraction and purification is a fundamental step that allows for highly sensitive amplification of specific RNA targets in PCR applications. However, commercial extraction kits that are broadly used because of their robustness and high yield of purified RNA are expensive and labor-intensive. In this study, boiling in distilled water or a commerical lysis buffer of different sample matrices containing avian or porcine influenza viruses was tested as an alternative. Real-time PCR (RTaPCR) for nucleoprotein gene fragment was used as read out. Results were compared with freshly extracted RNA by use of a commercial extraction kit. Different batches of virus containing material materials, including diluted virus positive allontoic fluid or cell culture supernatnat, and avian faecal, cloacal or oropharyngeal swab samples were used in this study. Simple boiling of samples without any additional purification steps can be used as an alternative RNA preparation method to detect influenza A virus nucleoprotein RNA in oropharyngeal swab samples, allantoic fluid or cell-culture supernatant. The boiling method is not applicable for sample matrices containing faecal material. (author)

  6. Development and Validation of a Real-Time PCR Assay for Rapid Detection of Candida auris from Surveillance Samples.

    Science.gov (United States)

    Leach, L; Zhu, Y; Chaturvedi, S

    2018-02-01

    Candida auris is an emerging multidrug-resistant yeast causing invasive health care-associated infection with high mortality worldwide. Rapid identification of C. auris is of primary importance for the implementation of public health measures to control the spread of infection. To achieve these goals, we developed and validated a TaqMan-based real-time PCR assay targeting the internal transcribed spacer 2 ( ITS 2) region of the ribosomal gene. The assay was highly specific, reproducible, and sensitive, with the detection limit of 1 C. auris CFU/PCR. The performance of the C. auris real-time PCR assay was evaluated by using 623 surveillance samples, including 365 patient swabs and 258 environmental sponges. Real-time PCR yielded positive results from 49 swab and 58 sponge samples, with 89% and 100% clinical sensitivity with regard to their respective culture-positive results. The real-time PCR also detected C. auris DNA from 1% and 12% of swab and sponge samples with culture-negative results, indicating the presence of dead or culture-impaired C. auris The real-time PCR yielded results within 4 h of sample processing, compared to 4 to 14 days for culture, reducing turnaround time significantly. The new real-time PCR assay allows for accurate and rapid screening of C. auris and can increase effective control and prevention of this emerging multidrug-resistant fungal pathogen in health care facilities. Copyright © 2018 Leach et al.

  7. Multiplex PCR-based assay for detection of Bordetella pertussis in nasopharyngeal swab specimens.

    Science.gov (United States)

    Wadowsky, R M; Michaels, R H; Libert, T; Kingsley, L A; Ehrlich, G D

    1996-11-01

    A multiplex PCR-based assay was developed for the detection of Bordetella pertussis in nasopharyngeal swab specimens. The assay simultaneously amplified two separate DNA targets (153 and 203 bp) within a B. pertussis repetitive element and a 438-bp target within the beta-actin gene of human DNA (PCR amplification control). PCR products were detected by a sensitive and specific liquid hybridization gel retardation assay. A total of 496 paired nasopharyngeal swab specimens were tested by both the PCR-based assay and culture. Although 30 (6%) of the specimens inhibited the amplification of the beta-actin target, in all 29 specimens studied, the inhibition disappeared on repeat testing or was easily overcome with a 1:8 dilution or less of specimen digest. Of the 495 specimen pairs yielding a final evaluable result by the PCR-based assay, 19.0% were positive by the PCR-based assay, whereas 13.9% were positive by culture (P < 0.0001). After resolving the PCR-positive, culture-negative results by testing an additional aliquot from these specimens by the multiplex PCR-based assay, the PCR-based assay had a sensitivity and specificity of 98.9 and 99.7%, respectively, compared with values of 73.4 and 100%, respectively, for culture. In comparison with patients with culture-confirmed pertussis, those with PCR-positive, culture-negative results were older and more likely to have had prolonged cough, immunization with pertussis vaccine, or treatment with erythromycin. This multiplex PCR-based assay is substantially more sensitive than culture and identifies specimens that contain inhibitors of PCR.

  8. Analysis of microbial diversity on deli slicers using polymerase chain reaction and denaturing gradient gel electrophoresis technologies.

    Science.gov (United States)

    Koo, O K; Mertz, A W; Akins, E L; Sirsat, S A; Neal, J A; Morawicki, R; Crandall, P G; Ricke, S C

    2013-02-01

    Cross-contamination of pathogenic and spoilage bacteria from food-contact surfaces to food products is a serious public health issue. Bacteria may survive and attach to food-contact surfaces by residual food components and/or background bacteria which may subsequently transfer to other food products. Deli slicers, generally used for slicing ready-to-eat products, can serve as potential sources for considerable bacterial transfer. The objective of this study was to assess the extent and distribution of microbial diversity of deli slicers by identification of pathogenic and background bacteria. Slicer-swab samples were collected from restaurants in Arkansas and Texas in the United States. Ten surface areas for each slicer were swabbed using sterile sponges. Denaturing gradient gel electrophoresis (DGGE) was applied to investigate the fingerprint of samples, and each band was further identified by sequence analysis. Pseudomonads were identified as the dominant bacteria followed by Enterobacteriaceae family, and lactic acid bacteria such as Lactococcus lactis and Streptococcus thermophilus were also found. Bacterial distribution was similar for all surface areas, while the blade guard exhibited the greatest diversity. This study provides a profile of the microbial ecology of slicers using DGGE to develop more specific sanitation practices and to reduce cross-contamination during slicing. © 2012 The Society for Applied Microbiology.

  9. ARCTOX: a pan-Arctic sampling network to track mercury contamination across Arctic marine food webs

    DEFF Research Database (Denmark)

    Fort, Jerome; Helgason, Halfdan; Amelineau, Francoise

    and is still a source of major environmental concerns. In that context, providing a large-scale and comprehensive understanding of the Arctic marine food-web contamination is essential to better apprehend impacts of anthropogenic activities and climate change on the exposure of Arctic species and humans to Hg....... In 2015, an international sampling network (ARCTOX) has been established, allowing the collection seabird samples all around the Arctic. Seabirds are indeed good indicators of Hg contamination of marine food webs at large spatial scale. Gathering researchers from 10 countries, ARCTOX allowed......Arctic marine ecosystems are threatened by new risks of Hg contamination under the combined effects of climate change and human activities. Rapid change of the cryosphere might for instance release large amounts of Hg trapped in sea-ice, permafrost and terrestrial glaciers over the last decades...

  10. OCCURRENCE OF LISTERIA MONOCYTOGENES IN READY TO EAT FOOD SAMPLES COLLECTED BY LOMBARDY REGION HEALTH AUTHORITIES IN 2009-2010

    Directory of Open Access Journals (Sweden)

    E. Oliverio

    2012-08-01

    Full Text Available The study provides data on the prevalence of Listeria monocytogenes in ready-to-eat food samples collected by Lombardy region health authorities and analyzed by Department of Food Microbiology, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia Romagna. From the total of 503 food samples analyzed, the pathogen was detected in 85 (16,9%. In particular it was highlighted in 8/152 (5,3% meat products, in 5/245 (2% dairy products and in 42/106 (39,6% fishery products. Given the considerable public health implications, the study confirms that a well-planned program of listeriosis surveillance should be enforced to suitably estimate the burden of disease and to prevent foodborne outbreaks.

  11. "On-off" switchable tool for food sample preparation: merging molecularly imprinting technology with stimuli-responsive blocks. Current status, challenges and highlighted applications.

    Science.gov (United States)

    Garcia, Raquel; Gomes da Silva, Marco D R; Cabrita, Maria João

    2018-01-01

    Sample preparation still remains a great challenge in the analytical workflow representing the most time-consuming and laborious step in analytical procedures. Ideally, sample pre-treatment procedures must be more selective, cheap, quick and environmental friendly. Molecular imprinting technology is a powerful tool in the development of highly selective sample preparation methodologies enabling to preconcentrate the analytes from a complex food matrix. Actually, the design and development of molecularly imprinted polymers-based functional materials that merge an enhancement of selectivity with a controllable and switchable mode of action by means of specific stimulus constitutes a hot research topic in the field of food analysis. Thus, combining the stimuli responsive mechanism and imprinting technology a new generation of materials are emerging. The application of these smart materials in sample preparation is in early stage of development, nevertheless new improvements will promote a new driven in the demanding field of food sample preparation. The new trends in the advancement of food sample preparation using these smart materials will be presented in this review and highlighted the most relevant applications in this particular area of knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Microbiological hazard analysis of ready-to-eat meats processed at a food plant in Trinidad, West Indies

    Directory of Open Access Journals (Sweden)

    Stacey-Marie Syne

    2013-07-01

    Full Text Available Background: A bacteriological assessment of the environment and food products at different stages of processing was conducted during the manufacture of ready-to-eat (RTE chicken franks, chicken bologna and bacon at a large meat processing plant in Trinidad, West Indies. Methods: Samples of air, surfaces (swabs, raw materials, and in-process and finished food products were collected during two separate visits for each product type and subjected to qualitative or quantitative analysis for bacterial zoonotic pathogens and fecal indicator organisms. Results: Staphylococcus aureus was the most common pathogen detected in pre-cooked products (mean counts = 0.66, 1.98, and 1.95 log10CFU/g for franks, bologna, and bacon, respectively. This pathogen was also found in unacceptable levels in 4 (16.7% of 24 post-cooked samples. Fifty percent (10 of 20 of pre-cooked mixtures of bacon and bologna were contaminated with Listeria spp., including four with L. monocytogenes. Pre-cooked mixtures of franks and bologna also contained E. coli (35 and 0.72 log10 CFU/g, respectively while 5 (12.5% of 40 pre-cooked mixtures of chicken franks had Salmonella spp. Aerobic bacteria exceeded acceptable international standards in 46 (82.1% of 56 pre-cooked and 6 (16.7% of 36 post-cooked samples. Both pre-and post-cooking air and surfaces had relatively high levels of aerobic bacteria, Staphylococcus aureus and coliforms, including equipment and gloves of employees. A drastic decrease in aerobic counts and Staphylococcus aureus levels following heat treatment and subsequent increase in counts of these bacteria are suggestive of post-cooking contamination. Conclusion: A relatively high level of risk exists for microbial contamination of RTE meats at the food plant investigated and there is a need for enhancing the quality assurance programs to ensure the safety of consumers of products manufactured at this plant.

  13. Seven-hour fluorescence in situ hybridization technique for enumeration of Enterobacteriaceae in food and environmental water sample.

    Science.gov (United States)

    Ootsubo, M; Shimizu, T; Tanaka, R; Sawabe, T; Tajima, K; Ezura, Y

    2003-01-01

    A fluorescent in situ hybridization (FISH) technique using an Enterobacteriaceae-specific probe (probe D) to target 16S rRNA was improved in order to enumerate, within a single working day, Enterobacteriaceae present in food and environmental water samples. In order to minimize the time required for the FISH procedure, each step of FISH with probe D was re-evaluated using cultured Escherichia coli. Five minutes of ethanol treatment for cell fixation and hybridization were sufficient to visualize cultured E. coli, and FISH could be performed within 1 h. Because of the difficulties in detecting low levels of bacterial cells by FISH without cultivation, a FISH technique for detecting microcolonies on membrane filters was investigated to improve the bacterial detection limit. FISH with probe D following 6 h of cultivation to grow microcolonies on a 13 mm diameter membrane filter was performed, and whole Enterobacteriaceae microcolonies on the filter were then detected and enumerated by manual epifluorescence microscopic scanning at magnification of x100 in ca 5 min. The total time for FISH with probe D following cultivation (FISHFC) was reduced to within 7 h. FISHFC can be applied to enumerate cultivable Enterobacteriaceae in food (above 100 cells g-1) and environmental water samples (above 1 cell ml-1). Cultivable Enterobacteriaceae in food and water samples were enumerated accurately within 7 h using the FISHFC method. A FISHFC method capable of evaluating Enterobacteriaceae contamination in food and environmental water within a single working day was developed.

  14. Application of immunoaffinity columns for different food item samples preparation in micotoxins determination

    Directory of Open Access Journals (Sweden)

    Ćurčić Marijana

    2016-01-01

    Full Text Available In analytical methods used for monitoring of what special attention is paid to sample preparation. Therefore, the objective of this study was testing the efficiency of immunoaffinity columns (IAC that are based on solid phase extraction principles used for samples preparation in determining aflatoxins and ochratoxins. Aflatoxins and ochratoxins concentrations were determined in totally 56 samples of food items: wheat, corn, rice, barley and other grains (19 samples, flour and flour products from grain and additives for the bakery industry (7 samples, fruits and vegetables (3 samples, hazelnut, walnut, almond, coconut flour (4 samples, roasted cocoa beans, peanuts, tea, coffee (16 samples, spices (4 samples and meat and meat products (4 samples. Obtained results indicate advantage of IAC use for sample preparation based on enhanced specificity due to binding of extracted molecules to incorporated specific antibodies and rinsing the rest molecules from sample which could interfere with further analysis. Additional advantage is the usage of small amount of organic solvents and consequently decreased exposure of staff who conduct micotoxins determination. Of special interest is increase in method sensitivity since limit of quantification for aflatoxins and ochratoxins determination method is lower than maximal allowed concentration of these toxines prescribed by national rule book.

  15. The Effect of Asymmetrical Sample Training on Retention Functions for Hedonic Samples in Rats

    Science.gov (United States)

    Simmons, Sabrina; Santi, Angelo

    2012-01-01

    Rats were trained in a symbolic delayed matching-to-sample task to discriminate sample stimuli that consisted of the presence of food or the absence of food. Asymmetrical sample training was provided in which one group was initially trained with only the food sample and the other group was initially trained with only the no-food sample. In…

  16. Combined method for the fast determination of pure beta emitting radioisotopes in food samples

    International Nuclear Information System (INIS)

    Kabai, Eva; Savkin, Birgit; Mehlsam, Isabell; Poppitz-Spuhler, Angela

    2017-01-01

    Fast radioanalytical methods are essential for a rapid response of decision makers. A fast method for the simultaneous determination of the pure beta emitting radionuclides 89 Sr/ 90 Sr and 99 Tc in food samples was developed. It includes the precipitation of fat and proteins with trichloroacetic acid for milk and dairy products and microwave digestion for other food products, followed by an anion exchange step to separate strontium from technetium. The purification steps for strontium and technetium are done using Sr-resin and TEVA-resin, respectively. Typical chemical yields are around 70 % for both radionuclides. The whole determination takes only around 20 h. (author)

  17. Concentrations of bisphenol A in the composite food samples from the 2008 Canadian total diet study in Quebec City and dietary intake estimates.

    Science.gov (United States)

    Cao, X-L; Perez-Locas, C; Dufresne, G; Clement, G; Popovic, S; Beraldin, F; Dabeka, R W; Feeley, M

    2011-06-01

    A total of 154 food composite samples from the 2008 total diet study in Quebec City were analysed for bisphenol A (BPA), and BPA was detected in less than half (36%, or 55 samples) of the samples tested. High concentrations of BPA were found mostly in the composite samples containing canned foods, with the highest BPA level being observed in canned fish (106 ng g(-1)), followed by canned corn (83.7 ng g(-1)), canned soups (22.2-44.4 ng g(-1)), canned baked beans (23.5 ng g(-1)), canned peas (16.8 ng g(-1)), canned evaporated milk (15.3 ng g(-1)), and canned luncheon meats (10.5 ng g(-1)). BPA levels in baby food composite samples were low, with 2.75 ng g(-1) in canned liquid infant formula, and 0.84-2.46 ng g(-1) in jarred baby foods. BPA was also detected in some foods that are not canned or in jars, such as yeast (8.52 ng g(-1)), baking powder (0.64 ng g(-1)), some cheeses (0.68-2.24 ng g(-1)), breads and some cereals (0.40-1.73 ng g(-1)), and fast foods (1.1-10.9 ng g(-1)). Dietary intakes of BPA were low for all age-sex groups, with 0.17-0.33 µg kg(-1) body weight day(-1) for infants, 0.082-0.23 µg kg(-1) body weight day(-1) for children aged from 1 to 19 years, and 0.052-0.081 µg kg(-1) body weight day(-1) for adults, well below the established regulatory limits. BPA intakes from 19 of the 55 samples account for more than 95% of the total dietary intakes, and most of the 19 samples were either canned or in jars. Intakes of BPA from non-canned foods are low.

  18. The major types of added sugars and non-nutritive sweeteners in a sample of Australian packaged foods.

    Science.gov (United States)

    Probst, Yasmine C; Dengate, Alexis; Jacobs, Jenny; Louie, Jimmy Cy; Dunford, Elizabeth K

    2017-12-01

    Limiting the intake of added sugars in the diet remains a key focus of global dietary recommendations. To date there has been no systematic monitoring of the major types of added sugars used in the Australian food supply. The present study aimed to identify the most common added sugars and non-nutritive sweeteners in the Australian packaged food supply. Secondary analysis of data from the Australian FoodSwitch database was undertaken. Forty-six added sugars and eight non-nutritive sweetener types were extracted from the ingredient lists of 5744 foods across seventeen food categories. Australia. Not applicable. Added sugar ingredients were found in 61 % of the sample of foods examined and non-nutritive sweetener ingredients were found in 69 %. Only 31 % of foods contained no added sugar or non-nutritive sweetener. Sugar (as an ingredient), glucose syrup, maple syrup, maltodextrin and glucose/dextrose were the most common sugar ingredient types identified. Most Australian packaged food products had at least one added sugar ingredient, the most common being 'sugar'. The study provides insight into the most common types of added sugars and non-nutritive sweeteners used in the Australian food supply and is a useful baseline to monitor changes in how added sugars are used in Australian packaged foods over time.

  19. Electromembrane extraction of tartrazine from food samples: Effects of nano-sorbents on membrane performance.

    Science.gov (United States)

    Yaripour, Saeid; Mohammadi, Ali; Nojavan, Saeed

    2016-07-01

    In the present study, for the first time electromembrane extraction followed by high-performance liquid chromatography coupled with ultraviolet detection was developed and validated for the determination of tartrazine in some food samples. The parameters influencing electromembrane extraction were evaluated and optimized. The membrane consists of 1-octanol immobilized in the pores of a hollow fiber. As a driving force, a 30 V electrical field was applied to make the analyte migrate from sample solution with pH 3, through the supported liquid membrane into an acceptor solution with pH 10. Best preconcentration (enrichment factor >21) was obtained in extraction duration of 15 min. Effects of some solid nano-sorbents like carbon nanotubes and molecularly imprinted polymers on membrane performance and electromembrane extraction efficiency were evaluated. The method provided the linearity in the range 25-1000 ng/mL for tartrazine (R(2) > 0.9996) with repeatability range (RSD) between 3.8 and 8.5% (n = 3). The limits of detection and quantitation were 7.5 and 25 ng/mL, respectively. Finally, the method was applied to the determination and quantification of tartrazine from some food samples with relative recoveries in the range between 90 and 98%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Anatomical characteristics of teats and premilking bacterial counts of teat skin swabs of primiparous cows exposed to different types of bedding.

    Science.gov (United States)

    Guarín, J F; Baumberger, C; Ruegg, P L

    2017-02-01

    Bacterial populations of teat skin are associated with risk of intramammary infection and may be influenced by anatomical characteristics of teats. The objective of this study was to evaluate associations of selected anatomical characteristics of teats with bacterial counts of teat skin of cows exposed to different types of bedding. Primarily primiparous Holstein cows (n = 128) were randomly allocated to 4 pens within a single barn. Each pen contained 1 type of bedding [new sand (NES), recycled sand (RS), deep-bedded manure solids (DBMS), and shallow-bedded manure solids over foam core mattresses (SBMS)]. During a single farm visit udders (n = 112) were scored for hygiene and 1 front (n = 112) and 1 rear teat (n = 111) of each enrolled cow were scored for hyperkeratosis (HK). Teat length, teat barrel diameter, and teat apex diameter were measured and teat skin swabs were systematically collected for microbiological analysis. Linear type evaluation data for udders of each cow were retrieved for each cow. Teat position (front or rear) was associated with occurrence of clinical mastitis during the 12 mo before the farm visit and more cases occurred in front quarters. The proportion of udders that were classified as clean (score 1 or 2) was 68, 82, 54, and 95% for cows housed in pens containing NES, RS, SBMS, and DBMS, respectively. No association was found between HK score and teat position and no association was found between HK score and teat skin bacterial count. Bacterial counts of teat skin swabs from front teats of cows in pens containing RS and SBMS were significantly less than those of rear teats of cows in pens containing DBMS or NES. Teat skin bacterial counts were significantly greater for swabs obtained from teats of cows with udder hygiene scores of 3 and 4 as compared with swabs obtained from cows with cleaner udders. Of all udder conformation traits evaluated, only narrower rear teat placement was positively associated with bacterial counts on teat skin

  1. Comparison of green sample preparation techniques in the analysis of pyrethrins and pyrethroids in baby food by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Petrarca, Mateus Henrique; Ccanccapa-Cartagena, Alexander; Masiá, Ana; Godoy, Helena Teixeira; Picó, Yolanda

    2017-05-12

    A new selective and sensitive liquid chromatography triple quadrupole mass spectrometry method was developed for simultaneous analysis of natural pyrethrins and synthetic pyrethroids residues in baby food. In this study, two sample preparation methods based on ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) and salting-out assisted liquid-liquid extraction (SALLE) were optimized, and then, compared regarding the performance criteria. Appropriate linearity in solvent and matrix-based calibrations, and suitable recoveries (75-120%) and precision (RSD values≤16%) were achieved for selected analytes by any of the sample preparation procedures. Both methods provided the analytical selectivity required for the monitoring of the insecticides in fruit-, cereal- and milk-based baby foods. SALLE, recognized by cost-effectiveness, and simple and fast execution, provided a lower enrichment factor, consequently, higher limits of quantification (LOQs) were obtained. Some of them too high to meet the strict legislation regarding baby food. Nonetheless, the combination of ultrasound and DLLME also resulted in a high sample throughput and environmental-friendly method, whose LOQs were lower than the default maximum residue limit (MRL) of 10μgkg -1 set by European Community for baby foods. In the commercial baby foods analyzed, cyhalothrin and etofenprox were detected in different samples, demonstrating the suitability of proposed method for baby food control. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Efficient recovery of fluoroquinolone-susceptible and fluoroquinolone-resistant Escherichia coli strains from frozen samples.

    Science.gov (United States)

    Lautenbach, Ebbing; Santana, Evelyn; Lee, Abby; Tolomeo, Pam; Black, Nicole; Babson, Andrew; Perencevich, Eli N; Harris, Anthony D; Smith, Catherine A; Maslow, Joel

    2008-04-01

    We assessed the rate of recovery of fluoroquinolone-resistant and fluoroquinolone-susceptible Escherichia coli isolates from culture of frozen perirectal swab samples compared with the results for culture of the same specimen before freezing. Recovery rates for these 2 classes of E. coli were 91% and 83%, respectively. The majority of distinct strains recovered from the initial sample were also recovered from the frozen sample. The strains that were not recovered were typically present only in low numbers in the initial sample. These findings emphasize the utility of frozen surveillance samples.

  3. Direct determination of cadmium in foods by solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry using a tungsten coil trap

    Science.gov (United States)

    Zhang, Ying; Mao, Xuefei; Liu, Jixin; Wang, Min; Qian, Yongzhong; Gao, Chengling; Qi, Yuehan

    2016-04-01

    In this work, a solid sampling device consisting of a tungsten coil trap, porous carbon vaporizer and on-line ashing furnace of a Ni-Cr coil was interfaced with inductively coupled plasma mass spectrometry (ICP-MS). A modified double gas circuit system was employed that was composed of carrier and supplemental gas lines controlled by separate gas mass flow controllers. For Cd determination in food samples using the assembled solid sampling ICP-MS, the optimal ashing and vaporization conditions, flow rate of the argon-hydrogen (Ar/H2) (v:v = 24:1) carrier gas and supplemental gas, and minimum sampling mass were investigated. Under the optimized conditions, the limit of quantification was 0.5 pg and the relative standard deviation was within a 10.0% error range (n = 10). Furthermore, the mean spiked recoveries for various food samples were 99.4%-105.9% (n = 6). The Cd concentrations measured by the proposed method were all within the certified values of the reference materials or were not significantly different (P > 0.05) from those of the microwave digestion ICP-MS method, demonstrating the good accuracy and precision of the solid sampling ICP-MS method for Cd determination in food samples.

  4. Diagnosis of canine visceral leishmaniasis with radiolabelled probes: comparison of the kDNA PCR-hybridization with three molecular methods in different clinical samples

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Aline Leandra C.; Ferreira, Sidney A.; Carregal, Virginia M.; Andrade, Antero Silva R., E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia; Melo, Maria N., E-mail: melo@icb.ufmg.br [Departamento de Parasitologia. Instituto de Ciencias Biologicas. Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2011-07-01

    Leishmania (Leishmania) chagasi is responsible for visceral leishmaniasis (VL) in Brazil and the dog is the main domestic reservoir. Disease control is based on the elimination of infected animals and the use of a sensitive and specific diagnostic test is necessary. The Brazilian VL control program emphasizes serologic surveys, mainly using the enzyme-linked immunosorbent assay (ELISA) and the immunofluorescence antibody test (IFAT), followed by the elimination of the seropositive dogs. However, these techniques present limitations in terms of sensitivity and specificity. The Polymerase Chain Reaction (PCR) associated to hybridization with DNA probes labeled with {sup 32}P has been recognized as a valuable tool for Leishmania identification. In this study, the sensitivity of kDNA PCR hybridization method was compared with three other molecular methods: Internal Transcribed Spacer 1 Nested PCR (ITS-1nPCR), Leishmania nested PCR (LnPCR) and Seminested kDNA PCR (kDNA snPCR). The comparison was performed in different clinical specimens: conjunctival swab, skin, blood and bone marrow. A group of thirty symptomatic dogs, positive in the parasitological and serological tests, was used. When. The techniques targeting kDNA mini-circles (kDNA snPCR and KDNA PCR-hybridization) showed the worst result for blood samples. The KDNA-PCR hybridization showed the best sensitivity for conjunctival swab. By comparing the samples on the basis of positivity obtained by the sum of all methods, the blood showed the worst outcome (71/120).The bone marrow showed the highest positivity (106/120), followed by conjunctival swab (100/120) and skin (89/120). Since the bone marrow samples are unsuitable for routine epidemiological surveys, the conjunctival swab was recommended because it allows high sensitivity, especially when associated with kDNA PCR hybridization method, and is a noninvasive sampling method. (author)

  5. Diagnosis of canine visceral leishmaniasis with radiolabelled probes: comparison of the kDNA PCR-hybridization with three molecular methods in different clinical samples

    International Nuclear Information System (INIS)

    Ferreira, Aline Leandra C.; Ferreira, Sidney A.; Carregal, Virginia M.; Andrade, Antero Silva R.

    2011-01-01

    Leishmania (Leishmania) chagasi is responsible for visceral leishmaniasis (VL) in Brazil and the dog is the main domestic reservoir. Disease control is based on the elimination of infected animals and the use of a sensitive and specific diagnostic test is necessary. The Brazilian VL control program emphasizes serologic surveys, mainly using the enzyme-linked immunosorbent assay (ELISA) and the immunofluorescence antibody test (IFAT), followed by the elimination of the seropositive dogs. However, these techniques present limitations in terms of sensitivity and specificity. The Polymerase Chain Reaction (PCR) associated to hybridization with DNA probes labeled with 32 P has been recognized as a valuable tool for Leishmania identification. In this study, the sensitivity of kDNA PCR hybridization method was compared with three other molecular methods: Internal Transcribed Spacer 1 Nested PCR (ITS-1nPCR), Leishmania nested PCR (LnPCR) and Seminested kDNA PCR (kDNA snPCR). The comparison was performed in different clinical specimens: conjunctival swab, skin, blood and bone marrow. A group of thirty symptomatic dogs, positive in the parasitological and serological tests, was used. When. The techniques targeting kDNA mini-circles (kDNA snPCR and KDNA PCR-hybridization) showed the worst result for blood samples. The KDNA-PCR hybridization showed the best sensitivity for conjunctival swab. By comparing the samples on the basis of positivity obtained by the sum of all methods, the blood showed the worst outcome (71/120).The bone marrow showed the highest positivity (106/120), followed by conjunctival swab (100/120) and skin (89/120). Since the bone marrow samples are unsuitable for routine epidemiological surveys, the conjunctival swab was recommended because it allows high sensitivity, especially when associated with kDNA PCR hybridization method, and is a noninvasive sampling method. (author)

  6. [Optimizing antibiotics policy in the Netherlands. VI. SWAB advice: no selective decontamination of intensive care patients on mechanical ventilation

    NARCIS (Netherlands)

    Bonten, M.J.; Kullberg, B.J.; Filius, P.M.

    2001-01-01

    The Working Party on Antibiotic Policy (Dutch acronym is SWAB) has issued a guideline in which the pro and cons of the routine use of selective decontamination (SD) in patients in intensive care (IC) on mechanical ventilation are compared in order to decide whether SD is indicated. The effectiveness

  7. A new approach to the investigation of sexual offenses-cytoskeleton analysis reveals the origin of cells found on forensic swabs.

    Science.gov (United States)

    Schulz, Martin M; Buschner, Maximilian G D; Leidig, Richard; Wehner, Heinz-D; Fritz, Peter; Häbig, Karina; Bonin, Michael; Schütz, Monika; Shiozawa, Thomas; Wehner, Frank

    2010-03-01

    There are forensic inquiries in which an identification of epithelial cell types would provide important probative evidence. In cancer diagnosis, this information is yielded by histological examination of cytokeratin (Ck). Therefore, we tested 19 antibodies against different Cks (Ck1, Ck2e, Ck4, Ck5-6, Ck7, Ck8, Ck9, CK10, Ck13, Ck14, Ck15, Ck16, Ck17, Ck18, Ck19, Ck20, Ck903, PanCkAE1_3, and CAM5-2) on histological sections of epidermis, buccal mucosa, vaginal mucosa, penis, urogenital tract, and rectum and could identify two antigens unique to buccal-cell and vaginal-cell (Ck4) and skin epithelial-cell (Ck10) cytokeratin. Subsequently, we developed an immunocytological technique for distinguishing swabbed skin and mucosal cells up to at least 1 year after sampling. By the detection of the Ck4 and Ck10 mRNAs in biopsy and laser capture microdissection collected samples via quantitative real-time polymerase chain reaction, we were able to confirm our immunological findings. Hence, this study offers techniques to discriminate between skin and mucosal cells (buccal and vaginal) in forensic casework.

  8. Aluminium content of foods originating from aluminium-containing food additives.

    Science.gov (United States)

    Ogimoto, Mami; Suzuki, Kumi; Haneishi, Nahoko; Kikuchi, Yuu; Takanashi, Mayu; Tomioka, Naoko; Uematsu, Yoko; Monma, Kimio

    2016-09-01

    Aluminium (Al) levels of 90 food samples were investigated. Nineteen samples contained Al levels exceeding the tolerable weekly intake (TWI) for young children [body weight (bw): 16 kg] when consuming two servings/week. These samples were purchased multiple times at specific intervals and were evaluated for Al levels. Al was detected in 27 of the 90 samples at levels ranging from 0.01 (limit of quantitation) to 1.06 mg/g. Of these, the Al intake levels in two samples (cookie and scone mix, 1.3 and 2 mg/kg bw/week, respectively) exceeded the TWI as established by European Food Safety Authority, although the level in the scone mix was equivalent to the provisional TWI (PTWI) as established by Joint Food and Agriculture Organization of the United Nations/World Health Organization Expert Committee on Food Additives. The Al levels markedly decreased in 14 of the 19 samples with initially high Al levels. These results indicated reductions in the Al levels to below the PTWI limits in all but two previously identified food samples.

  9. Measuring the gut microbiome in birds: Comparison of faecal and cloacal sampling.

    Science.gov (United States)

    Videvall, Elin; Strandh, Maria; Engelbrecht, Anel; Cloete, Schalk; Cornwallis, Charlie K

    2018-05-01

    The gut microbiomes of birds and other animals are increasingly being studied in ecological and evolutionary contexts. Numerous studies on birds and reptiles have made inferences about gut microbiota using cloacal sampling; however, it is not known whether the bacterial community of the cloaca provides an accurate representation of the gut microbiome. We examined the accuracy with which cloacal swabs and faecal samples measure the microbiota in three different parts of the gastrointestinal tract (ileum, caecum, and colon) using a case study on juvenile ostriches, Struthio camelus, and high-throughput 16S rRNA sequencing. We found that faeces were significantly better than cloacal swabs in representing the bacterial community of the colon. Cloacal samples had a higher abundance of Gammaproteobacteria and fewer Clostridia relative to the gut and faecal samples. However, both faecal and cloacal samples were poor representatives of the microbial communities in the caecum and ileum. Furthermore, the accuracy of each sampling method in measuring the abundance of different bacterial taxa was highly variable: Bacteroidetes was the most highly correlated phylum between all three gut sections and both methods, whereas Actinobacteria, for example, was only strongly correlated between faecal and colon samples. Based on our results, we recommend sampling faeces, whenever possible, as this sample type provides the most accurate assessment of the colon microbiome. The fact that neither sampling technique accurately portrayed the bacterial community of the ileum nor the caecum illustrates the difficulty in noninvasively monitoring gut bacteria located further up in the gastrointestinal tract. These results have important implications for the interpretation of avian gut microbiome studies. © 2017 John Wiley & Sons Ltd.

  10. Comparison of Lateral Flow Assay, Kidney Inhibition Swab, and Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Penicillin G Residues in Sow Urine.

    Science.gov (United States)

    Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J

    2017-03-01

    Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.

  11. Characteristics of cytotoxic necrotizing factor and cytolethal distending toxin producing Escherichia coli strains isolated from meat samples in Northern Ireland.

    Science.gov (United States)

    Kadhum, H J; Ball, H J; Oswald, E; Rowe, M T

    2006-08-01

    Swabs collected from pig, lamb and beef carcasses and samples of pork, lamb and beef mince were cultured for Escherichia coli strains. Strains harbouring cytotoxic necrotizing factors (CNF1 and 2) and cytolethal distending toxins (CDT-I,-II,-III and -IV) were identified in plate cultures of the isolates by colony hybridization with labelled probes and multiplex PCR assays. Simplex and multiplex PCR assays were used to further characterize the isolates to determine the presence of P, S and F17 fimbriae as well as afimbrial adhesins and haemolysin. The serotype was also determined where possible. Thirty strains with the capacity to code for CNF (4), CDT (24) or both (2) were isolated and characterized, and a wide range of associated factor patterns was observed. The methods utilized were successful in demonstrating the detection of viable strains with potentially significant pathogenic factors from human food sources.

  12. The high vaginal swab in general practice: clinical correlates of possible pathogens.

    Science.gov (United States)

    Dykhuizen, R S; Harvey, G; Gould, I M

    1995-06-01

    Clinical features, diagnosis and treatment of 286 women whose high vaginal swabs (HVS) submitted by their general practitioners showed pure, heavy growth of Staphylococcus aureus, beta haemolytic streptococci groups A, C or G, Streptococcus milleri, Streptococcus pneumoniae or Haemophilus influenzae were analysed. Women with group A, C and G streptococci frequently had clinical vulvovaginitis and although the numbers were too small for statistical confirmation, S. pneumoniae and H. influenzae appeared to cause clinical disease as well. The association of S. aureus or S. milleri with clinical vulvovaginitis was much less convincing. It seems relevant for laboratories to report sensitivities for group A, C and G streptococci. Further research is needed to determine the pathogenicity of S. pneumoniae and H. influenzae.

  13. Development of a non-thermal accelerated pulsed UV photolysis assisted digestion method for fresh and dried food samples

    International Nuclear Information System (INIS)

    Solis, C.; Lagunas-Solar, M.C.; Perley, B.P.; Pina, C.; Aguilar, L.F.; Flocchini, R.G.

    2002-01-01

    A simple, fast digestion procedure for fresh and dried foods, using high-power pulsed UV photolysis in the presence of hydrogen peroxide, is being developed. The homogenized food samples were mixed with H 2 O 2 or with a mixture of H 2 O 2 and HNO 3 , and irradiated for short times with a 248-nm UV excimer laser. After centrifugation, a clear, colorless solution was obtained and aliquots were deposited on Teflon filters for XRF and/or PIXE analyses. Standard reference materials (NIST Peach Leaves; Typical Diet) were also analyzed to compare recoveries and detection limits. Improvements in detection limits were observed, but a few trace elements (<1 ppm) were not reproducibly detected (Fe, Sr). This method proved to be practical for the accelerated digestion of food samples and preparing analytes in short-time intervals. In combination with PIXE and XRF, it allows high-sensitivity multi-elemental analyses for screening the nutritional elements and for food safety purposes regarding the potential presence of toxic elements. Further development to optimize and validate this procedure for a broader range of analytes is in progress

  14. Food Sample Preparation for the Determination of Sulfonamides by High-Performance Liquid Chromatography: State-of-the-Art

    Directory of Open Access Journals (Sweden)

    Dimitrios Bitas

    2018-06-01

    Full Text Available Antibiotics are a common practice in veterinary medicine, mainly for therapeutic purposes. Sectors of application include livestock farming, aquacultures, and bee-keeping, where bacterial infections are frequent and can be economically damaging. However, antibiotics are usually administered in sub-therapeutic doses as prophylactic and growth promoting agents. Due to their excessive use, antibiotic residues can be present in foods of animal origin, which include meat, fish, milk, eggs, and honey, posing health risks to consumers. For this reason, authorities have set maximum residue limits (MRLs of certain antibiotics in food matrices, while analytical methods for their determination have been developed. This work focuses on antibiotic extraction and determination, part of which was presented at the “1st Conference in Chemistry for Graduate, Postgraduate Students and PhD Candidates at the Aristotle University of Thessaloniki”. Taking a step further, this paper is a review of the most recent sample preparation protocols applied for the extraction of sulfonamide antibiotics from food samples and their determination with high-performance liquid chromatography (HPLC, covering a five-year period.

  15. ELISA AND SOL-GEL BASED IMMUNOAFFINITY PURIFICATION OF THE PYRETHROID BIOALLETHRIN IN FOOD AND ENVIRONMENTAL SAMPLES

    Science.gov (United States)

    The peer-reviewed article describes the development of a new sol-gel based immunoaffinity purification procedure and an immunoassay for the pyrethroid bioallethrin. The immunoaffinity chromatography procedure was applied to food samples providing an efficient cleanup prior to im...

  16. Determination of penicillin-G procaine in kidney, muscle, serum, and urine of heavy sows after intramuscular administration

    Science.gov (United States)

    The United States Department of Agriculture Food Safety and Inspection Service (FSIS) recently adapted the use of the Charm Kidney Inhibition Swab (KIS) test for screening antibiotics on-site, along with a LC-MS/MS method for confirmation of KIS-positive samples. A study with 126 heavy sows (227.0 ...

  17. Application of kidney inhibition swab tests to evaluate penicillin-G residues in sow tissues and body fluids following intramuscular injection

    Science.gov (United States)

    Kidney inhibition swab (KIS) tests, recently adapted by the US FSIS for antibiotics on-site screening, were employed to evaluate the depletion of penicillin-G residues from kidney, liver, muscle, serum, and urine of sows after intramuscular (IM) penicillin-G procaine administration. Sows (n=130; 22...

  18. Application of the neutron activation analysis method for determing trace elements in Brazilian food sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1988-01-01

    Recently there has been an increase of consciousness about the importance of trace elements in human health and disease as well as rising concern about food contamination. The development of sensitive, accurate and price methods is one of the most important of the knowledge of trace elements contents in foods and in biological samples. Neutron activation analysis is one of the most suitable tecniques because a great number of elements can be determined in concentrations in the range of μg/g to ng/g. The present work is a part of an AIEA Co-ordinated Research Programme on the applications of nuclear techniques for toxic elements in foodstuffs. Neutron activation analysis is applied to analysis of bread, milk powder and rice that are considered essential foods in the Brazilian diet. Some aspects of the activation analysis of biological matrices are discussed. (author) [pt

  19. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  20. Trace determination of 10 beta-lactam antibiotics in environmental and food samples by capillary liquid chromatography.

    Science.gov (United States)

    Bailón-Pérez, M I; García-Campaña, A M; del Olmo-Iruela, M; Gámiz-Gracia, L; Cruces-Blanco, C

    2009-11-20

    A sensitive and reliable method using capillary HPLC with UV-diode array detection (DAD) has been developed and validated for the trace determination of residues of 10 beta-lactam antibiotics of human and veterinary use, in milk, chicken meat and environmental water samples. The analytes included ampicillin, amoxicillin, penicillin V, penicillin G, cloxacillin, oxacillin, dicloxacillin, nafcillin, piperacillin and clavulanic acid. Legal levels are regulated by the EU Council regulation 2377/90 in animal edible tissues for these compounds. For food analysis, a solid-phase extraction (SPE) procedure consisting in a tandem of Oasis HLB and Alumina N cartridges was applied for off-line preconcentration and cleanup. For water analysis, the first step was only necessary. The limits of detection for the studied compounds were between 0.04-0.06 microg l(-1) for water samples and 0.80-1.40 microg l(-1) (or microg kg(-1)) in the case of foods derived from animals. Average recoveries for fortified samples at different concentration levels ranged between 82.9% and 98.2%, with relative standard deviations (RSDs) lower than 9%. The method showed the advantages of capillary HPLC for the detection of these widely applied antibiotics in different samples at very low concentration levels.

  1. Separation and characterization of nanoparticles in complex food and environmental samples by field-flow fractionation

    DEFF Research Database (Denmark)

    Kammer, Frank von der; Legros, Samuel; Hofmann, Thilo

    2011-01-01

    The thorough analysis of natural nanoparticles (NPs) and engineered NPs involves the sequence of detection, identification, quantification and, if possible, detailed characterization. In a complex or heterogeneous sample, each step of this sequence is an individual challenge, and, given suitable...... has been applied for separation of various types of NP (e.g., organic macromolecules, and carbonaceous or inorganic NPs) in different types of media (e.g., natural waters, soil extracts or food samples).FFF can be coupled to different types of detectors that offer additional information...... conditions on all types of NP in the sample. A holistic methodological approach is preferable to a technique-focused one....

  2. Numerical model for surge and swab pressures on wells with cross-section variation

    Energy Technology Data Exchange (ETDEWEB)

    Fedevjcyk, Joao Victor; Junqueira, Silvio Luiz de Mello; Negrao, Cezar Otaviano Ribeiro [UTFPR - Federal University of Technology - Parana - Curitiba, PR (Brazil)], e-mails: silvio@utfpr.edu.br, negrao@utfpr.edu.br

    2010-07-01

    Drilling is one of the most complex steps in petroleum exploration. The process is accomplished by rotating a drill bit to compress the rock formation. During drilling, a fluid is pumped into the well to lubricate and cool down the drill bit, to clean up the well, to avoid the formation fluid influx to the well and also to stabilize the borehole walls. Fluid circulation, however, can be interrupted for maintenance reasons and the drill pipe can be moved to remove the drill bit. The downward or upward movement of the drill pipe displaces the fluid within the well causing either under pressure (swab) or over pressure (surge), respectively. If the pressure at the well bore overcomes the formation fracture pressure, a loss of circulation can take place. On the other way round, the upward movement may reduce the pressure below the pore pressure and an inflow of fluid to the well (kick) can occur. An uncontrolled kick may cause a blowout with serious damages. The transient flow induced by the axial movement of the drill pipe is responsible for the pressure changes at the well bore. Nevertheless, the well bore cross section variation may modify the pressure change within the pipe. In this paper, the effects of diameter variation of the drilling well on the surge and swab pressures are investigated. The equations that represent the phenomenon (mass and momentum conservation) are discretized by the finite volume method. Despite its non-Newtonian properties, the fluid is considered Newtonian in this first work. The drill pipe is considered closed and the flow is assumed as single-phased, one-dimensional, isothermal, laminar, compressible and transient. A sensitivity analysis of the flow parameters is carried out. The cross-section changes cause the reflection of the pressure wave, and consequently pressure oscillations. (author)

  3. Comparison of room temperature and cyrogenic sample processing in the analysis of chemical contaminants in foods

    Science.gov (United States)

    In this study, analytical results were compared when using different approaches to bulk food sample comminution, consisting of a vertical chopper (Blixer) at room temperature and at dry ice cryogenic conditions, followed by further subsample processing (20 g) using liquid nitrogen cryogenic conditio...

  4. PTSD, food addiction, and disordered eating in a sample of primarily older veterans: The mediating role of emotion regulation.

    Science.gov (United States)

    Mitchell, Karen S; Wolf, Erika J

    2016-09-30

    Posttraumatic stress disorder (PTSD) has been associated with eating disorders (EDs) and addictive behaviors, including the relatively new construct food addiction. However, few studies have investigated mechanisms that account for these associations, and men are underrepresented in studies of EDs and food addiction. We examined whether lifetime PTSD symptoms were associated with current food addiction and ED symptoms, and whether emotion regulation (expressive suppression and cognitive reappraisal), which has been associated with both PTSD and EDs, mediated these relations, in a sample of trauma-exposed, male (n=642) and female (n=55) veterans. Participants were recruited from the Knowledge Networks-GfK Research Panel and completed an online questionnaire. Structural equation modeling revealed that PTSD was directly associated with ED symptoms, food addiction, expressive suppression, and cognitive reappraisal in the full sample and with all constructs except cognitive reappraisal in the male subsample. Expressive suppression was significantly associated with ED symptoms and mediated the PTSD-ED relation. These results highlight the importance of investigating PTSD as a risk factor for food addiction and ED symptoms and the potential mediating role of emotion regulation in the development of PTSD and EDs in order to identify targets for treatments. Published by Elsevier Ireland Ltd.

  5. Rapid detection of Van genes in rectal swabs by real time PCR in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Vlademir Cantarelli

    2011-10-01

    Full Text Available INTRODUCTION: Laboratory-based surveillance is an important component in the control of vancomycin resistant enterococci (VRE. METHODS: The study aimed to evaluate real-time polymerase chain reaction (RT-PCR (genes vanA-vanB for VRE detection on 115 swabs from patients included in a surveillance program. RESULTS: Sensitivity of RT-PCR was similar to primary culture (75% and 79.5%, respectively when compared to broth enriched culture, whereas specificity was 83.1%. CONCLUSIONS: RT-PCR provides same day results, however it showed low sensitivity for VRE detection.

  6. Microorganisms as an Indicator of Hygiene Status Among Migrant Food Handlers in Peninsular Malaysia.

    Science.gov (United States)

    Woh, Pei Yee; Thong, Kwai Lin; Lim, Yvonne Ai Lian; Behnke, Jerzy Marian; Lewis, John Watkin; Mohd Zain, Siti Nursheena

    2017-10-01

    This study used microbial indicators to assess the hygiene status of 383 migrant food handlers from 3 urban cities in Peninsular Malaysia. Microbiological analysis revealed that all the hand swabs tested 99.5% positive for aerobic plate counts (mean [M] ± standard deviation [SD] = 3.57 ± 0.83 log 10 CFU [colony forming unit]), 20.8% positive for total coliform/ Escherichia coli (M ± SD = 0.30 ± 0.67 log 10 CFU), and 63.4% positive for Staphylococcus aureus (M ± SD = 1.38 ± 1.26 log 10 CFU). In addition, aerobic plate counts and Staphylococcus aureus counts exceeded the acceptable standard levels. Bacterial counts were found to be significantly associated with subjects' country of origin ( P = .019) and working responsibilities ( P = .001). Our findings indicate high probability of transmission of pathogenic bacteria from the food handlers' hands to customers during meal preparation and serving. This calls for improvements in personal hygiene and sanitation standards by the relevant health authorities among migrant food handlers.

  7. Low-calorie sweeteners in food and food supplements on the Italian market.

    Science.gov (United States)

    Janvier, Steven; Goscinny, Séverine; Le Donne, Cinzia; Van Loco, Joris

    2015-01-01

    This study determines the occurrence and concentration levels of artificial low-calorie sweeteners (LCSs) in food and food supplements on the Italian market. The analysed sample set (290 samples) was representative of the Italian market and comprised of beverages, jams, ketchups, confectionery, dairy products, table-top sweeteners and food supplements. All samples were analysed via UPLC-MS/MS. The method was in-house validated for the analysis of seven LCSs (aspartame, acesulfame-K, saccharin, sucralose, cyclamate, neotame and neohesperidin dihydrochalcone) in food and for five LCSs (aspartame, acesulfame-K, saccharin, cyclamate and sucralose) in food supplements. Except for cyclamate in one beverage which exceeded the maximum level (ML) with 13%, all concentrations measured in food were around or below the ML. In food supplements, 40 of the 52 samples (77%) were found to be above the ML, with exceedances of up to 200% of the ML.

  8. Multiplex real-time PCR assays for detection of eight Shiga toxin-producing Escherichia coli in food samples by melting curve analysis.

    Science.gov (United States)

    Singh, Prashant; Mustapha, Azlin

    2015-12-23

    Shiga toxin-producing Escherichia coli (STEC) are pathogenic strains of E. coli that can cause bloody diarrhea and kidney failure. Seven STEC serogroups, O157, O26, O45, O103, O111, O121 and O145 are responsible for more than 71% of the total infections caused by this group of pathogens. All seven serogroups are currently considered as adulterants in non-intact beef products in the U.S. In this study, two multiplex melt curve real-time PCR assays with internal amplification controls (IACs) were standardized for the detection of eight STEC serogroups. The first multiplex assay targeted E. coli serogroups O145, O121, O104, and O157; while the second set detected E. coli serogroups O26, O45, O103 and O111. The applicability of the assays was tested using 11 different meat and produce samples. For food samples spiked with a cocktail of four STEC serogroups with a combined count of 10 CFU/25 g food, all targets of the multiplex assays were detected after an enrichment period of 6h. The assays also worked efficiently when 325 g of food samples were spiked with 10 CFU of STECs. The assays are not dependent on fluorescent-labeled probes or immunomagnetic beads, and can be used for the detection of eight STEC serogroups in less than 11h. Routine preliminary screening of STECs in food samples is performed by testing for the presence of STEC virulence genes. The assays developed in this study can be useful as a first- or second-tier test for the identification of the eight O serogroup-specific genes in suspected food samples. Copyright © 2015. Published by Elsevier B.V.

  9. Simultaneous determination of caffeine, theophylline and theobromine in food samples by a kinetic spectrophotometric method.

    Science.gov (United States)

    Xia, Zhenzhen; Ni, Yongnian; Kokot, Serge

    2013-12-15

    A novel kinetic spectrophotometric method was developed for the simultaneous determination of caffeine, theobromine and theophylline in food samples. This method was based on the different kinetic characteristics between the reactions of analytes with cerium sulphate in sulphuric acid and the associated change in absorbance at 320 nm. Experimental conditions, the effects of sulphuric acid, cerium sulphate and temperature, were optimised. Linear ranges (0.4-8.4 μg mL(-1)) for all three analytes were established, and the limits of detection were: 0.30 μg mL(-1) (caffeine), 0.33 μg mL(-1) (theobromine) and 0.16 μg mL(-1) (theophylline). The recorded data were processed by partial least squares and artificial neural network, and the developed mathematical models were then used for prediction. The proposed, novel method was applied to determine the analytes in commercial food samples, and there were no significant differences between the results from the proposed method and those obtained by high-performance liquid chromatography. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Determination of haemolytic and non haemolytic genes profiles of Bacillus cereus strains isolated from food samples by polymerase chain reaction (pcr) technique

    Science.gov (United States)

    Jawad, Nisreen; Ahemd, Asmat; Abdullah, Aminah

    2018-04-01

    The aim of this study was to investigate the presence of Bacillus cereus and detection of enterotoxigenic genes in food samples by utilizing a Polymerase Chain Reaction technique (PCR). In this study the providence of B. cereus was carried out to food samples. The B. cereus isolates were investigated for enterotoxigenic gene. The cooked seafood, and raw milk samples were purchased from several restaurants and market in the area of (Bangi, Kajang, Serdang and UKM) Selangor, Malaysia. A total of 60 samples have been analyzed. B. cereus contamination has been formed between 1.4×105 - 3×105 cfu/mL of cooked seafood and raw milk samples. Five colonies have been detected as B. cereus using biochemical test. All B. cereus isolates named BC1 to BC27, were characterized for haemolytic enterotoxin (HBL) complex encoding genes (hblA), non-haemolytic enterotoxin encoding gene (NheA). 10 isolates have been reported to be positive towards hblA and 12 isolates were positive towards NheA. The presence of B. cereus and their enterotoxigenic genes in cooked seafood and raw milk from to food samples obtained may pose a potential risk for public health.

  11. Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples

    Science.gov (United States)

    Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...

  12. Detection of Small Numbers of Campylobacter jejuni and Campylobacter coli Cells in Environmental Water, Sewage, and Food Samples by a Seminested PCR Assay

    Science.gov (United States)

    Waage, Astrid S.; Vardund, Traute; Lund, Vidar; Kapperud, Georg

    1999-01-01

    A rapid and sensitive assay was developed for detection of small numbers of Campylobacter jejuni and Campylobacter coli cells in environmental water, sewage, and food samples. Water and sewage samples were filtered, and the filters were enriched overnight in a nonselective medium. The enrichment cultures were prepared for PCR by a rapid and simple procedure consisting of centrifugation, proteinase K treatment, and boiling. A seminested PCR based on specific amplification of the intergenic sequence between the two Campylobacter flagellin genes, flaA and flaB, was performed, and the PCR products were visualized by agarose gel electrophoresis. The assay allowed us to detect 3 to 15 CFU of C. jejuni per 100 ml in water samples containing a background flora consisting of up to 8,700 heterotrophic organisms per ml and 10,000 CFU of coliform bacteria per 100 ml. Dilution of the enriched cultures 1:10 with sterile broth prior to the PCR was sometimes necessary to obtain positive results. The assay was also conducted with food samples analyzed with or without overnight enrichment. As few as ≤3 CFU per g of food could be detected with samples subjected to overnight enrichment, while variable results were obtained for samples analyzed without prior enrichment. This rapid and sensitive nested PCR assay provides a useful tool for specific detection of C. jejuni or C. coli in drinking water, as well as environmental water, sewage, and food samples containing high levels of background organisms. PMID:10103261

  13. Multicenter validation of PCR-based method for detection of Salmonella in chicken and pig samples

    DEFF Research Database (Denmark)

    Malorny, B.; Cook, N.; D'Agostino, M.

    2004-01-01

    As part of a standardization project, an interlaboratory trial including 15 laboratories from 13 European countries was conducted to evaluate the performance of a noproprietary polymerase chain reaction (PCR)-based method for the detection of Salmonella on artificially contaminated chicken rinse...... or positive. Outlier results caused, for example, by gross departures from the experimental protocol, were omitted from the analysis. For both the chicken rinse and the pig swab samples, the diagnostic sensitivity was 100%, with 100% accordance (repeatability) and concordance (reproducibility). The diagnostic...... specificity was 80.1% (with 85.7% accordance and 67.5% concordance) for chicken rinse, and 91.7% (with 100% accordance and 83.3% concordance) for pig swab. Thus, the interlaboratory variation due to personnel, reagents, thermal cyclers, etc., did not affect the performance of the method, which...

  14. Concentrations of bisphenol A in the composite food samples from the 2008 Canadian total diet study in Quebec City and dietary intake estimates

    OpenAIRE

    Cao, X.-L.; Perez-Locas, C.; Dufresne, G.; Clement, G.; Popovic, S.; Beraldin, F.; Dabeka, R.W.; Feeley, M.

    2011-01-01

    A total of 154 food composite samples from the 2008 total diet study in Quebec City were analysed for bisphenol A (BPA), and BPA was detected in less than half (36%, or 55 samples) of the samples tested. High concentrations of BPA were found mostly in the composite samples containing canned foods, with the highest BPA level being observed in canned fish (106 ng g−1), followed by canned corn (83.7 ng g−1), canned soups (22.2–44.4 ng g−1), canned baked beans (23.5 ng g−1), canned peas (16.8 ng ...

  15. Executive control resources and frequency of fatty food consumption: findings from an age-stratified community sample.

    Science.gov (United States)

    Hall, Peter A

    2012-03-01

    Fatty foods are regarded as highly appetitive, and self-control is often required to resist consumption. Executive control resources (ECRs) are potentially facilitative of self-control efforts, and therefore could predict success in the domain of dietary self-restraint. It is not currently known whether stronger ECRs facilitate resistance to fatty food consumption, and moreover, it is unknown whether such an effect would be stronger in some age groups than others. The purpose of the present study was to examine the association between ECRs and consumption of fatty foods among healthy community-dwelling adults across the adult life span. An age-stratified sample of individuals between 18 and 89 years of age attended two laboratory sessions. During the first session they completed two computer-administered tests of ECRs (Stroop and Go-NoGo) and a test of general cognitive function (Wechsler Abbreviated Scale of Intelligence); participants completed two consecutive 1-week recall measures to assess frequency of fatty and nonfatty food consumption. Regression analyses revealed that stronger ECRs were associated with lower frequency of fatty food consumption over the 2-week interval. This association was observed for both measures of ECR and a composite measure. The effect remained significant after adjustment for demographic variables (age, gender, socioeconomic status), general cognitive function, and body mass index. The observed effect of ECRs on fatty food consumption frequency was invariant across age group, and did not generalize to nonfatty food consumption. ECRs may be potentially important, though understudied, determinants of dietary behavior in adults across the life span.

  16. Prevalence of 'Food Addiction' as Measured with the Yale Food Addiction Scale 2.0 in a Representative German Sample and Its Association with Sex, Age and Weight Categories.

    Science.gov (United States)

    Hauck, Carolin; Weiß, Annegret; Schulte, Erica Marla; Meule, Adrian; Ellrott, Thomas

    2017-01-01

    To assess the prevalence and correlates of addictive-like eating behavior in Germany. The German version of the Yale Food Addiction Scale (YFAS) 2.0 was used to investigate, for the first time, the prevalence of 'food addiction' in a representative sample aged 18-65 years (N = 1,034). The prevalence of 'food addiction' measured by the YFAS 2.0 was 7.9%. Individuals meeting criteria for 'food addiction' had higher BMI and were younger than individuals not meeting the threshold. Underweight (15.0%) and obese (17.2%) individuals exhibited the highest prevalence rate of 'food addiction'. Addictive-like eating was not associated with sex, education level, or place of residence. YFAS 2.0 'food addiction' was met by nearly 8% of the population. There is a non-linear relationship between addictive-like eating and BMI, with the highest prevalence among underweight and obese persons. These findings suggest that 'food addiction' may be a contributor to overeating but may also reflect a distinct phenotype of problematic eating behavior not synonymous with obesity. Further, the elevated prevalence of YFAS 2.0 'food addiction' among underweight individuals may reflect an overlap with eating disorders and warrants attention in future research. © 2017 The Author(s) Published by S. Karger GmbH, Freiburg.

  17. Comparison between the efficacy of two cleanup methods for the 1H NMR analysis of food samples contaminated with Cypermethrin

    International Nuclear Information System (INIS)

    Silva, M.M.; Figueroa-Villar, J.D.; Aguiar, A.P.; Riehl, C.A.S.

    2004-01-01

    This work aimed to study the use of 1 H NMR for the identification of cypermethrin in cooked foods. 1 H NMR is not commonly used in these cases, because food samples ready for consumption have complex substances, mainly lipids, which usually interfere with the identification of cypermethrin. Thus, we drew a comparison between the most applied method for the treatment of those samples and an alternative route that made possible the use of 1 H NMR in the identification of cypermethrin in a matrix consisting of rice, bean, and chicken, which allows the Forensic work for such cases.(author)

  18. Automated extraction of DNA from reference samples from various types of biological materials on the Qiagen BioRobot EZ1 Workstation

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Jørgensen, Mads; Hansen, Anders Johannes

    2009-01-01

    , and muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpFlSTR« Identifiler« and AmpFlSTR« Yfiler« (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types......We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs...... of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025...

  19. Healthy food choices are happy food choices: Evidence from a real life sample using smartphone based assessments.

    Science.gov (United States)

    Wahl, Deborah R; Villinger, Karoline; König, Laura M; Ziesemer, Katrin; Schupp, Harald T; Renner, Britta

    2017-12-06

    Research suggests that "healthy" food choices such as eating fruits and vegetables have not only physical but also mental health benefits and might be a long-term investment in future well-being. This view contrasts with the belief that high-caloric foods taste better, make us happy, and alleviate a negative mood. To provide a more comprehensive assessment of food choice and well-being, we investigated in-the-moment eating happiness by assessing complete, real life dietary behaviour across eight days using smartphone-based ecological momentary assessment. Three main findings emerged: First, of 14 different main food categories, vegetables consumption contributed the largest share to eating happiness measured across eight days. Second, sweets on average provided comparable induced eating happiness to "healthy" food choices such as fruits or vegetables. Third, dinner elicited comparable eating happiness to snacking. These findings are discussed within the "food as health" and "food as well-being" perspectives on eating behaviour.

  20. Quantification of total aluminium concentrations in food samples at trace levels by INAA and PIGE methods

    International Nuclear Information System (INIS)

    Nanda, Braja B.; Acharya, R.

    2017-01-01

    Total aluminium contents in various food samples were determined by Instrumental Neutron Activation Analysis (INAA) and Particle Induced Gamma-ray Emission (PIGE) methods. A total of 16 rice samples, collected from the field, were analyzed by INAA using reactor neutrons from Dhruva reactor. Whereas a total 17 spices collected from market, were analyzed by both INAA and PIGE methods in conjunction with high resolution gamma-ray spectrometry. Aluminium concentration values were found to be in the range of 19-845 mg kg -1 for spices and 15-104 mg kg -1 for rice samples. The methods were validated by analyzing standard reference materials (SRMs) form NIST. (author)

  1. "Doing Difference" and Fast Food Consumption: Patterns Among a Sample of White and African American Emerging Adults.

    Science.gov (United States)

    Wade, Jeannette M

    2018-04-01

    Previous research has demonstrated that frequent consumption of fast food is linked to obesity and that trends in both are disparate across race and sex categories. Contextualizing race- and sex-related factors that structure fast food consumption in emerging adulthood is a much-needed contribution to social research. Specifically, this study uses the "doing difference" framework, to examine the frequency of fast food consumption in a sample of White and African American (18-25 years old). According to the framework, social inequalities are reproduced through dramaturgical performances of race, class, and gender. Results of this suggest that feminine gender orientation and education serve as protective factors, while African American race and male sex serve as risk factors. African American women emerged as especially high risk given their higher prevalence of traditionally masculine traits.

  2. Colorimetric DNAzyme Biosensor for Convenience Detection of Enterotoxin B Harboring Staphylococcus aureus from Food Samples.

    Science.gov (United States)

    Mondal, Bhairab; N, Bhavanashri; Ramlal, Shylaja; Kingston, Joseph

    2018-02-14

    In the present study, a colorimetric DNAzymes biosensor strategy was devised in combination with immunomagnetic separation for rapid and easy detection of enterotoxin B harboring Staphylococcus aureus from food and clinical samples. The method employs immunocapture of S. aureus and amplification of seb gene by DNAzyme complementary sequence integrated forward primer and with specific reverse primer. The DNAzyme sequence integrated dsDNA PCR products when treated with hemin and TMB (3,3',5,5'-tetramethylbenzidine) in the presence of H 2 O 2 produce colorimetric signal. A linear relationship of optical signal with the initial template of seb was obtained which could be monitored by visually or spectrophotrometrically for qualitative and quantitative detection. The limit of detection for the assay was approximately 10 2 CFU/mL of seb gene harboring target. This method is convenient compared to gel based and ELISA systems. Further, spiking studies and analysis on natural samples emphasized the robustness and applicability of developed method. Altogether, the established assay could be a reliable alternative, low-cost, viable detection tool for the routine investigation of seb from food and clinical sources.

  3. [Trends and factors associated with food insecurity in Brazil: the National Household Sample Survey, 2004, 2009, and 2013].

    Science.gov (United States)

    Santos, Taíse Gama Dos; Silveira, Jonas Augusto Cardoso da; Longo-Silva, Giovana; Ramires, Elyssia Karine Nunes Mendonça; Menezes, Risia Cristina Egito de

    2018-03-29

    The aim of this study was to analyze trends and factors associated with food insecurity in Brazil in 2004, 2009, and 2013, using microdata from the National Household Sample Survey (PNAD). Food insecurity was assessed using the Brazilian Food Insecurity Scale. Independent variables were selected from a conceptual model of determination of food insecurity, which was also used in the elaboration of multiple generalized linear models. The results show a downward trend in food insecurity prevalence from 2004 to 2013, especially for moderate and severe food insecurity, from 17% in 2004 (95%CI: 15.7-18.4) to 7.9% in 2013 (95%CI: 7.2-8.7). Despite important decreases in the prevalence of moderate and severe food insecurity, regardless of the level of determination, the population strata with the lowest prevalence in 2004 showed the largest relative reduction. As for factors associated with moderate and severe food insecurity, they remained the same in the ten years covered by the PNAD survey, namely: the North and Northeast regions, urban areas with inadequate sanitation, household density > 2 persons per bedroom, ≤ 4 household durable consumer goods, and households headed by females, individuals insecurity dropped by half, but from the perspective of equity the advances occurred unequally and were lower in strata with greater social, economic, and demographic vulnerability.

  4. Attitudes toward health and taste of food among women with bulimia nervosa and women of a non-clinical sample.

    Science.gov (United States)

    Koritar, Priscila; Philippi, Sonia Tucunduva; Alvarenga, Marle Dos Santos

    2017-06-01

    Taste preferences and health concerns play important roles in determining eating attitudes, thus influencing food choices. Disordered eating attitudes are common among women, and can lead to the development and maintenance of eating disorders (ED). Attitudes toward health and taste of food among ED patients and its comparison with non-clinical women are not well known, and this knowledge could improve eating interventions. In this study, we compared taste preferences and health concerns in 27 women with diagnosis of bulimia nervosa (BN) and 216 women of a non-clinical sample. All participants completed the Health and Taste Attitude Scale (HTAS). Using analysis of covariance we compared the HTAS scores of the BN patients with those of the college students. Risk behaviors for ED (assessed by the Eating Attitudes Test) were identified in 54 (25%) of the non-clinical sample, all of whom were therefore excluded in comparison of BN patients. Non-clinical sample, compared to patients, scored higher on the HTAS Taste domain (p Health domain (p attitudes of women of non-clinical sample are related to taste and pleasure, whereas women with BN are concerned with adopting a diet regarded as healthy, thus increasing their interest in "light" products. Therefore, the taste and health concerns must be considered in nutrition interventions for women in general, and prevention and treatment of ED as determinants of food choice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Pre-exposure to food temptation reduces subsequent consumption: A test of the procedure with a South-African sample.

    Science.gov (United States)

    Duh, Helen Inseng; Grubliauskiene, Aiste; Dewitte, Siegfried

    2016-01-01

    It has been suggested that the consumption of unhealthy Westernized diet in a context of poverty and resultant food insecurity may have contributed to South-Africa's status of the third fattest country in the World. Considering that a number of South-Africans are reported to have experienced, or are still experiencing food insecurity, procedures which have been shown to reduce the consumption of unhealthy food in higher income countries may be ineffective in South-Africa. We thus tested the robustness of the so called pre-exposure procedure in South-Africa. We also tested the moderating role of childhood poverty in the pre-exposure procedure. With the pre-exposure procedure, a respondent is exposed to a tempting unhealthy food (e.g. candy) in a context that is designed such that eating the food interferes with a task goal. The typical result is that this procedure spills over and reduces consumption of similar tempting food later on. An experimental study conducted in a South-African laboratory showed that the pre-exposure effect is robust even with a sample, where food insecurity prevails. Childhood poverty did not moderate the effect. This study proves that behavioral procedures aimed at reducing the consumption of unhealthy food would be valuable in less rich non-Western countries. Further testing of the robustness of the pre-exposure effect is however recommended in other poorer food insecure countries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Sampling methods for the study of pneumococcal carriage: a systematic review.

    Science.gov (United States)

    Gladstone, R A; Jefferies, J M; Faust, S N; Clarke, S C

    2012-11-06

    Streptococcus pneumoniae is an important pathogen worldwide. Accurate sampling of S. pneumoniae carriage is central to surveillance studies before and following conjugate vaccination programmes to combat pneumococcal disease. Any bias introduced during sampling will affect downstream recovery and typing. Many variables exist for the method of collection and initial processing, which can make inter-laboratory or international comparisons of data complex. In February 2003, a World Health Organisation working group published a standard method for the detection of pneumococcal carriage for vaccine trials to reduce or eliminate variability. We sought to describe the variables associated with the sampling of S. pneumoniae from collection to storage in the context of the methods recommended by the WHO and those used in pneumococcal carriage studies since its publication. A search of published literature in the online PubMed database was performed on the 1st June 2012, to identify published studies that collected pneumococcal carriage isolates, conducted after the publication of the WHO standard method. After undertaking a systematic analysis of the literature, we show that a number of differences in pneumococcal sampling protocol continue to exist between studies since the WHO publication. The majority of studies sample from the nasopharynx, but the choice of swab and swab transport media is more variable between studies. At present there is insufficient experimental data that supports the optimal sensitivity of any standard method. This may have contributed to incomplete adoption of the primary stages of the WHO detection protocol, alongside pragmatic or logistical issues associated with study design. Consequently studies may not provide a true estimate of pneumococcal carriage. Optimal sampling of carriage could lead to improvements in downstream analysis and the evaluation of pneumococcal vaccine impact and extrapolation to pneumococcal disease control therefore

  7. A new approach for the determination of sulphur in food samples by high-resolution continuum source flame atomic absorption spectrometer.

    Science.gov (United States)

    Ozbek, N; Baysal, A

    2015-02-01

    The new approach for the determination of sulphur in foods was developed, and the sulphur concentrations of various fresh and dried food samples determined using a high-resolution continuum source flame atomic absorption spectrometer with an air/acetylene flame. The proposed method was optimised and the validated using standard reference materials, and certified values were found to be within the 95% confidence interval. The sulphur content of foods ranged from less than the LOD to 1.5mgg(-1). The method is accurate, fast, simple and sensitive. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Evaluation of the HB&L carbapenemase and extended spectrum beta lactamase-AmpC automated screening kits for the rapid detection of resistant Enterobacteriaceae in rectal swabs

    Directory of Open Access Journals (Sweden)

    Sara Marani

    2017-03-01

    Full Text Available Background. In the past two decades, a rapid increase of infections due to multidrug-resistant Enterobacteriaceae was reported worldwide, including in Italy. These bacteria express genes encoding for extended-spectrum β-lactamases (ESBL or bear a plasmid-mediated AmpC that induce phenotypically a resistance to the last-generation cephalosporins; even more worrying is the rapid increase of Enterobacteriaceae carrying genes conferring resistance to carbapenems (CPE. Materials and methods. The gut may serve as reservoir for these antibiotic drug-resistant bacteria: as a consequence, the rapid detection of drug resistant Enterobacteriaceae from rectal swabs is an important tool to identify rectal carriage of resistant bacteria. This procedure is the basic tool to successfully implement the infection control measures in the hospital wards. The study evaluated the capability of the HB&L ESBL/AmpC and CARBAPENEMASE screening kit (Alifax, Padua, Italy to rapidly identify the drug resistant enterobacteriaceae from rectal swabs: the performance was compared with the conventional method. Results and conclusions. The overall agreement was very good (91% for the detection of ESBL-AmpC, and 96.2% for the identification of CPE; this method is thus an efficient tool to quickly report positive multidrug resistant bacteria in rectal swabs.

  9. Evaluation of a PCR Assay for Detection of Streptococcus pneumoniae in Respiratory and Nonrespiratory Samples from Adults with Community-Acquired Pneumonia

    Science.gov (United States)

    Murdoch, David R.; Anderson, Trevor P.; Beynon, Kirsten A.; Chua, Alvin; Fleming, Angela M.; Laing, Richard T. R.; Town, G. Ian; Mills, Graham D.; Chambers, Stephen T.; Jennings, Lance C.

    2003-01-01

    Streptococcus pneumoniae is the most common cause of community-acquired pneumonia, but it is undoubtedly underdiagnosed. We used a nested PCR assay (targeting the pneumolysin gene) to detect S. pneumoniae DNA in multiple sample types from 474 adults with community-acquired pneumonia and 183 control patients who did not have pneumonia. Plasma or buffy coat samples were PCR positive in only 6 of the 21 patients with positive blood cultures for S. pneumoniae and in 12 other patients (4 of whom had no other laboratory evidence of S. pneumoniae infection). Buffy coat samples from two control patients (neither having evidence of S. pneumoniae infection), but no control plasma samples, were PCR positive. Although pneumococcal antigen was detected in the urine from 120 of 420 (29%) patients, only 4 of 227 (2%) urine samples tested were PCR positive. Overall, 256 of 318 (81%) patients had PCR-positive sputum samples, including 58 of 59 samples from which S. pneumoniae was cultured. Throat swab samples from 229 of 417 (55%) patients were PCR positive and, in those who produced sputum, 96% also had positive PCR results from sputum. Throat swabs from 73 of 126 (58%) control patients were also PCR positive. We conclude that the pneumolysin PCR assay adds little to existing diagnostic tests for S. pneumoniae and is unable to distinguish colonization from infection when respiratory samples are tested. PMID:12517826

  10. Comparison between the efficacy of two cleanup methods for the {sup 1}H NMR analysis of food samples contaminated with Cypermethrin

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.M.; Figueroa-Villar, J.D.; Aguiar, A.P. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Dept. de Quimica; Riehl, C.A.S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Quimica. Dept. de Quimica Analitica]. E-mail: riehl@iq.ufrj

    2004-07-01

    This work aimed to study the use of {sup 1}H NMR for the identification of cypermethrin in cooked foods. {sup 1}H NMR is not commonly used in these cases, because food samples ready for consumption have complex substances, mainly lipids, which usually interfere with the identification of cypermethrin. Thus, we drew a comparison between the most applied method for the treatment of those samples and an alternative route that made possible the use of {sup 1}H NMR in the identification of cypermethrin in a matrix consisting of rice, bean, and chicken, which allows the Forensic work for such cases.(author)

  11. Determination of Antimicrobial Activity of Sorrel (Hibiscus sabdariffa) on Esherichia coli O157:H7 Isolated from Food, Veterinary, and Clinical Samples

    Science.gov (United States)

    Fullerton, Marjorie; Khatiwada, Janak; Johnson, Jacqueline U.; Davis, Shurrita

    2011-01-01

    Abstract The use of medicinal plants as natural antimicrobial agents is gaining popularity. Sorrel (Hibiscus sabdariffa) is widely used for the treatment of diseases. The objective of this study was to investigate the antimicrobial activity of sorrel on Escherichia coli O157:H7 isolates from food, veterinary, and clinical samples. Phenolics of the calyces were extracted from 10 g of ground, freeze-dried samples using 100 mL of 80% aqueous methanol. Concentrations of 10%, 5%, and 2.5% methanol extract of sorrel were investigated for its antimicrobial activity. Inhibition zones were indicated by a lack of microbial growth due to inhibitory concentrations of sorrel diffused into semisolid culture medium beneath the sorrel-impregnated disk. The results of this experiment showed that the most potent sorrel concentration was 10%, then 5%, and finally 2.5%. The overall mean zone of inhibition for the sorrel extract was 12.66 mm for 10%, 10.75 mm for 5%, and 8.9 mm for 2.5%. The highest inhibition zones (11.16 mm) were observed in veterinary samples, and the lowest (10.57 mm) in the food samples. There were significant (P<.05) differences among mean zones of inhibition found in the food, veterinary, and clinical sources. Based on the source of samples and concentration of sorrel extract, the lowest mean inhibition was 7.00±0.04 mm from clinical samples, and the highest was 15.37±0.61 mm from a food source. These findings indicated that sorrel was effective at all levels in inhibiting E. coli O157:H7; thus it possesses antimicrobial activity and hold great promise as an antimicrobial agent. PMID:21548802

  12. Salmonella detection in poultry samples. Comparison of two commercial real-time PCR systems with culture methods for the detection of Salmonella spp. in environmental and fecal samples of poultry.

    Science.gov (United States)

    Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M

    2012-01-01

    The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.

  13. Risk assessment of cooking utensils role of the bacterial contamination in the hospital kitchen

    Directory of Open Access Journals (Sweden)

    Monireh Majlesi Nasr

    2014-08-01

    Full Text Available Background: Food contact surfaces are a major concern for food services facilities in controlling the spread of food borne pathogens. This study was aimed to investigate roles of food utensils in transmission of the most important bacteria associated with nosocomial infections and hospital food borne diseases in one hospital in Tehran. Materials and methods: During the three independent sampling processes, samples of common used utensils were analyzed for bacterial contamination. Through a sterile swab the samples were collected in sterile tubes and after transferring, were immediately subjected to culture on gram negative specific and general media for bacteria. Total bacterial counts of each sample were determined and their characterizations were performed by biochemical diagnostic tests according to standards methods. Results: Among the studied cooking utensils’ and food samples, the most contaminated samples were determined as samples from board and blender as 38% and 35%, respectively. The most bacteria isolated from these samples were related to species of Enterobacteriaceae, Staphylococcus aureus, Klebsiella pneumoniae and Bacillus species that were similar to the isolates from studied food samples. Conclusion: Results of this study, in addition to high contamination rates of medical foods and utensils in their contact showed that there are significant weaknesses in proper cooking and utensils hygiene conditions in preparation and distribution of medical food in the studied hospital’s samples.

  14. Enzyme sensor array for the determination of biogenic amines in food samples

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Jana [University of Greifswald, Institute for Chemistry and Biochemistry (Germany); Wittmann, Christine [Fachhochschule Neubrandenburg, Department of Technology (Germany)

    2002-01-01

    An enzyme sensor array for the simultaneous determination of the three biogenic amines (histamine, tyramine and putrescine) by pattern recognition using an artificial neural network and its application to different food samples is described. A combination of a monoamine oxidase, a tyramine oxidase and a diamine oxidase (with specific activities sufficient for rapid detection) are immobilised each on a separate screen-printed thick-film electrode via transglutaminase and glutaraldehyde to compare these cross-linking reagents with regard to their suitability. To calculate the amount of a specific biogenic amine, the raw data from multichannel software were transferred to a neural network. The sensor array takes 20 min to complete (excluding statistical data analysis) with only one extraction and subsequent neutralisation step required prior to sensor measurement. The lower detection limits with the enzyme sensor were 10 mg/kg for histamine and tyramine, and 5 mg/kg for putrescine with a linear range up to 200 mg/kg for histamine and tyramine and 100 mg/kg for putrescine. The application area of the enzyme sensor array was tested from fish to meat products, sauerkraut, beer, dairy products, wine and further fermented foods and compared with the data of conventional LC analyses (mean correlation coefficient: 0.854). (orig.)

  15. Technical note: Discard the specimen collection swab directly at point of care to improve extensive automated processing in clinical microbiology laboratories.

    Science.gov (United States)

    Avolio, Manuela; Grosso, Shamanta; Bruschetta, Graziano; Camporese, Alessandro

    2016-10-01

    We compared, in terms of microorganisms recovery, the discard of specimen collection swab, after swirling into its medium, directly at point of care, with its placing into the medium and vortexing on arrival in the laboratory. Our results show that these two procedures are overlapped in terms of bacterial recovery. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Multidimensional analysis of food-allergic children and adolescents' self-concept: A comparison with a healthy matched sample.

    Science.gov (United States)

    Polloni, Laura; Baldi, Ileana; Lazzarotto, Francesca; Bonaguro, Roberta; Toniolo, Alice; Gregori, Dario; Muraro, Antonella

    2015-06-01

    The study investigated self-concept in food-allergic youths and matched healthy controls. Global and domain-specific self-concepts were assessed in 154 participants (9-19 years) using the Multidimensional Self-Concept Scale. Statistical analysis assessed differences between the two samples and effects of asthma, dermatitis, age, and gender among patients. Significant differences were found for Total Scale score and for Competence and Physical scores. Patients showed clinically problematic self-concepts in Global, Competence, and Family domains. Age was found to be associated with the Total score. Health professionals should consider food-allergic patients' personality development. Further studies could examine disease-specific consequences and interventions. © The Author(s) 2015.

  17. Safety Evaluation of Oil Samples Collected from Different Food Points of Multan City of Pakistan

    Directory of Open Access Journals (Sweden)

    Saeed Akhtar

    2018-05-01

    Full Text Available Cooking oil has become a part and parcel of modern food system and therefore its safety is of prime significance for health agencies around the globe to ensure good health among the community. Current study was designed to investigate the physicochemical properties including free fatty acids, peroxide value and conjugated dienes; minerals (nickel & cobalt and heavy metals (lead and cadmium in oil samples collected from different areas of Multan city of Pakistan. The findings of this study revealed that free fatty acid percentages, conjugated dienes, cobalt and nickel concentrations were in normal ranges while the peroxide values, lead and cadmium concentrations were recorded above the norms. Strict regulatory measures need to be adopted to ensure good quality oil supply and to protect the people from health implications of physicochemical and metallic hazards prevailing in fried oils and fried foods.

  18. Behavioral Contexts, Food-Choice Coping Strategies, and Dietary Quality of a Multiethnic Sample of Employed Parents

    Science.gov (United States)

    Blake, Christine E.; Wethington, Elaine; Farrell, Tracy J.; Bisogni, Carole A.; Devine, Carol M.

    2012-01-01

    Employed parents’ work and family conditions provide behavioral contexts for their food choices. Relationships between employed parents’ food-choice coping strategies, behavioral contexts, and dietary quality were evaluated. Data on work and family conditions, sociodemographic characteristics, eating behavior, and dietary intake from two 24-hour dietary recalls were collected in a random sample cross-sectional pilot telephone survey in the fall of 2006. Black, white, and Latino employed mothers (n=25) and fathers (n=25) were recruited from a low/moderate income urban area in upstate New York. Hierarchical cluster analysis (Ward’s method) identified three clusters of parents differing in use of food-choice coping strategies (ie, Individualized Eating, Missing Meals, and Home Cooking). Cluster sociodemographic, work, and family characteristics were compared using χ2 and Fisher’s exact tests. Cluster differences in dietary quality (Healthy Eating Index 2005) were analyzed using analysis of variance. Clusters differed significantly (P≤0.05) on food-choice coping strategies, dietary quality, and behavioral contexts (ie, work schedule, marital status, partner’s employment, and number of children). Individualized Eating and Missing Meals clusters were characterized by nonstandard work hours, having a working partner, single parenthood and with family meals away from home, grabbing quick food instead of a meal, using convenience entrées at home, and missing meals or individualized eating. The Home Cooking cluster included considerably more married fathers with nonemployed spouses and more home-cooked family meals. Food-choice coping strategies affecting dietary quality reflect parents’ work and family conditions. Nutritional guidance and family policy needs to consider these important behavioral contexts for family nutrition and health. PMID:21338739

  19. Accuracy of reported food intake in a sample of 7-10 year-old children in Serbia.

    Science.gov (United States)

    Šumonja, S; Jevtić, M

    2016-09-01

    Children's ability to recall and report dietary intake is affected by age and cognitive skills. Dietary intake reporting accuracy in children is associated with age, weight status, cognitive, behavioural, social factors and dietary assessment techniques. This study analysed accuracy of 7-10 year-old children's reported food intake for one day. Validation study. Sample included 94 children aged 7-10 years (median = 9 years) from two elementary schools in a local community in Serbia. 'My meals for one day' questionnaire was a combination of 24-h recall and food recognition form. It included recalls for five meals: breakfast at home; snack at home; lunch at home; snack at school and dinner at home. Parental reports were used as reference information about children's food intake for meals obtained at home and observation was used to gain reference information for school meal. Observed and reported amounts were used to calculate omission rate, intrusion rate, corresponding, over-reported and unreported amounts of energy, correspondence rate and inflation ratio. Overall omission rate (37.5%) was higher than overall intrusion rate (36.7%). The same food item (bread) has been the most often correctly reported and omitted food item for breakfast, lunch and dinner. Snack at school had the greatest mean correspondence rate (79.6%) and snack at home the highest mean inflation ratio (90.7%). Most errors in children's recalls were incorrectly reported amounts and not the food items. The questionnaire should be improved to facilitate accurate reports of the amounts. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  20. Detection of Methicillin Resistant Staphylococcus aureus and Determination of Minimum Inhibitory Concentration of Vancomycin for Staphylococcus aureus Isolated from Pus/Wound Swab Samples of the Patients Attending a Tertiary Care Hospital in Kathmandu, Nepal

    Directory of Open Access Journals (Sweden)

    Raghabendra Adhikari

    2017-01-01

    Full Text Available The present study was conducted to evaluate the performance of cefoxitin disc diffusion method and oxacillin broth microdilution method for detection of methicillin resistant S. aureus (MRSA, taking presence of mecA gene as reference. In addition, inducible clindamycin resistance and beta-lactamase production were studied and minimum inhibitory concentration (MIC of vancomycin for S. aureus isolates was determined. A total of 711 nonrepeated pus/wound swab samples from different anatomic locations were included in the study. The Staphylococcus aureus was identified on the basis of colony morphology, Gram’s stain, and biochemical tests. A total of 110 (15.47% S. aureus isolates were recovered, of which 39 (35.50% isolates were identified as MRSA by cefoxitin disc diffusion method. By oxacillin broth microdilution method, 31.82% of the Staphylococcus aureus isolates were found to be MRSA. However, mecA gene was present in only 29.1% of the isolates. Further, beta-lactamase production was observed in 71.82% of the isolates, while inducible clindamycin resistance was found in 10% of S. aureus isolates. The MIC value of vancomycin for S. aureus ranged from 0.016 μg/mL to 1 μg/mL. On the basis of the absolute sensitivity (100%, both phenotypic methods could be employed for routine diagnosis of MRSA in clinical microbiology laboratory; however cefoxitin disc diffusion could be preferred over MIC method considering time and labour factor.

  1. Association between junk food consumption and mental health in a national sample of Iranian children and adolescents: the CASPIAN-IV study.

    Science.gov (United States)

    Zahedi, Hoda; Kelishadi, Roya; Heshmat, Ramin; Motlagh, Mohammad Esmaeil; Ranjbar, Shirin Hasani; Ardalan, Gelayol; Payab, Moloud; Chinian, Mohammad; Asayesh, Hamid; Larijani, Bagher; Qorbani, Mostafa

    2014-01-01

    The consumption of high energy and low nutritional content foods, which are known as junk foods, has increased. The aim of this study was to evaluate the association between junk food intake and mental health in a national sample of Iranian children and adolescents. Data were obtained from a surveillance system entitled CASPIAN-IV (Childhood and Adolescence Surveillance and Prevention of Adult Non communicable Disease) study of school students, ages 6 to 18 y in Iran. The students and their parents completed two sets of reliable questionnaires obtained from Global School Health Survey translated to Persian. The student questionnaire comprised several questions such as psychiatric distress (worry, depression, confusion, insomnia, anxiety, aggression, and worthless) and violent behaviors (physical fighting, being a victim, and bullying). The junk foods consisted of sweets, sweetened beverages, fast foods, and salty snacks. In the sample of 13 486 children and adolescents, the frequency of junk food consumption was significantly associated with psychiatric distress (P junk foods (P 0.05). Additionally, the results of logistic regression showed that daily consumption of sweetened beverages and snacks significantly increased the odds of self-reported psychiatric distress. Also, daily consumption of salty snacks was significantly associated with violent behavior, including physical fighting (odds ratio [OR], 1.39; 95% confidence interval [CI], 1.21-1.60), being a victim (OR, 1.19; 95% CI, 1.04-1.37), and bullying (OR, 1.55; 95% CI, 1.32-1.82). Junk food consumption may increase the risk for psychiatric distress and violent behaviors in children and adolescents. Improvement of eating habits toward healthier diets may be an effective approach for improving mental health. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Prevalence and Molecular Detection of Quinolone-Resistant E. coli in Rectal Swab of Apparently Healthy Cattle in Bangladesh

    OpenAIRE

    Md. Montasir Mamun; Jayedul Hassan; K. H. M. Nazmul Hussain Nazir; Md. Alimul Islam; Khalada Zesmin; Md. Bahanur Rahman; Md. Tanvir Rahman

    2017-01-01

    Emergence of antibiotic resistance is a serious health problem both in human and animal all over the world. In this study, we investigated the prevalence of quinolone-resistant E. coli isolated from apparently healthy cattle in Mymensingh district, Bangladesh. A total of 137 rectal swabs was screened among which 95 was found positive for E. coli. Confirmation of isolation of E. coli was done by PCR targeting 16S rRNA gene of E. coli (prevalence 69.3%). Resistance against quinolone is primaril...

  3. Rapid Analysis of U isotopic ratios in Food Stuff samples using Fusion and ICP-MS measurement: For radiation monitoring program in the vicinity of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong Myoung; Park, Ji Young; Jung, Yoon Hee; Kim, Hyun Cheol; Kim, Won Young; Chung, Gun Ho; Kang, Mun Ja [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, a rapid digestion and separation method for U isotopes was developed in food stuff matrix such as cabbage and rice. As an attempt to reduce social costs and apprehension arising from the radioactivity in food, an accurate and rapid assessment of radioactivity is highly desirable. Hence, it is very important to develop a series of evaluation of rapid procedures for efficient radioactivity management in food. Contrary to the α-spectrometry method, a measurement technique using ICP-MS with an advanced sample introduction and mass counting system allows radioactivity in many samples to be measured with a short time period with a high degree of accuracy and precision. In order to satisfy the method detectable activity (MDA) for the regulation of radioactivity monitoring program the analysis of U isotopes always require the extremely large sample amount. These procedures make usually the food stuff sample to carbonize during dry ashing process. The ashed residues have been especially complicated into a liquid phase because of their carbonization. This process are very time consuming and not fully recovered target isotopes.

  4. Core food of the French food supply: second Total Diet Study.

    Science.gov (United States)

    Sirot, V; Volatier, J L; Calamassi-Tran, G; Dubuisson, C; Menard, C; Dufour, A; Leblanc, J C

    2009-05-01

    As first described in the 1980s, the core food intake model allows a precise assessment of dietary nutrient intake and dietary exposure to contaminants insofar as it reflects the eating habits of a target population and covers the most important foods in terms of consumption, selected nutrient and contaminant contribution. This model has been used to set up the sampling strategy of the second French Total Diet Study (TDS) with the aim of obtaining a realistic panorama of nutrient intakes and contaminant exposure for the whole population, useful for quantitative risk assessment. Data on consumption trends and eating habits from the second French individual food consumption survey (INCA2) as well as data from a 2004 purchase panel of French households (SECODIP) were used to identify the core foods to be sampled. A total of 116 core foods on a national scale and 70 core foods on a regional scale were selected according to (1) the consumption data for adults and children, (2) their consumer rates, and (3) their high contribution to exposure to one or more contaminants of interest. Foods were collected in eight French regions (36 cities) and prepared 'as consumed' to be analysed for their nutritional composition and contamination levels. A total of 20 280 different food products were purchased to make up the 1352 composite samples of core foods to be analysed for additives, environmental contaminants, pesticide residues, trace elements and minerals, mycotoxins and acrylamide. The establishment of such a sampling plan is essential for effective, high-quality monitoring of dietary exposure from a public health point of view.

  5. Improved diagnosis of Trichomonas vaginalis infection by PCR using vaginal swabs and urine specimens compared to diagnosis by wet mount microscopy, culture, and fluorescent staining

    NARCIS (Netherlands)

    C. van der Schee (Cindy); A.F. van Belkum (Alex); L. Zwijgers (Lisette); E. van der Brugge; E.L. O'Neill; A. Luijendijk (Ad); T. van Rijsoort-Vos; W.I. van der Meijden (Willem); J.F. Sluiters (Hans); H.A. Verbrugh (Henri)

    1999-01-01

    textabstractFour vaginal cotton swab specimens were obtained from each of 804 women visiting the outpatient sexually transmitted disease clinic of the Erasmus University Medical Center Rotterdam, Rotterdam, The Netherlands, for validation of various forms of Trichomonas

  6. Quantification of hygiene indicators and Salmonella in the tonsils, oral cavity and rectal content samples of pigs during slaughter.

    Science.gov (United States)

    Van Damme, Inge; Mattheus, Wesley; Bertrand, Sophie; De Zutter, Lieven

    2018-05-01

    The tonsils, oral cavity and faeces of 94 pigs at slaughter were sampled to assess the numbers of total aerobic bacteria, Enterobacteriaceae and Escherichia coli in the rectal content, tonsils and oral cavity of pigs at time of evisceration. Moreover, the prevalence, numbers and types of Salmonella spp. were determined. Mean numbers of Enterobacteriaceae in tonsils and the oral cavity differed between slaughterhouses. The proportion of Enterobacteriaceae relative to total aerobic bacteria differed between the different tissues, though large variations were observed between animals. Salmonella spp. were mostly detected in oral cavity swabs (n = 51, 54%), of which six samples were contaminated in numbers over 2.0 log CFU/100 cm 2 . Salmonella spp. were also recovered from 17 tonsillar tissue samples (18%) and 12 tonsillar swabs (13%). Out of the 29 rectal content samples from which Salmonella was recovered (31%), most were lowly contaminated, in the range between -1 and 0 log CFU/g. The predominant serotypes were S. Typhimurium and its monophasic variant, which were recovered from 33 and 13 pigs, respectively. In most cases, the same serotypes and MLVA profiles were found in pigs slaughtered during the same day, thus suggesting a common source of contamination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. La variedad, diversidad y características de la dieta en muestras de conveniencia de mujeres guatemaltecas Food variety, dietary diversity, and food characteristics among convenience samples of Guatemalan women

    Directory of Open Access Journals (Sweden)

    María José Soto-Méndez

    2011-08-01

    Full Text Available OBJETIVO: Comparar patrones y características de diversidad y variedad de la dieta de mujeres guatemaltecas. MATERIEL Y MÉTODOS: Se realizaron dos recordatorios de 24-horas en una muestra de conveniencia de 20 mujeres rurales y 20 estudiantes urbanas. Se calcularon puntajes de diversidad usando tres sistemas de grupos alimentarios. La variedad y diversidad, así como el origen y características de la dieta, se compararon entre ambos sitios. RESULTADOS: La variedad y diversidad en general fueron mayores en la muestra urbana en comparación con la muestra rural, dependiendo del número de días y del sistema de grupos de alimentos utilizados para la evaluación. La dieta rural fue predominantemente vegetal y compuesta de alimentos tradicionales no procesados. La dieta urbana estaba basada primordialmente en alimentos procesados. CONCLUSIÓN: Las consideraciones para crear estrategias de intervención para el mejoramiento de la dieta en el área rural dependen de la conservación de la selección de alimentos tradicionales.OBJECTIVE: To compare variety and diversity patterns and dietary characteristics in Guatemalan women. MATERIAL AND METHODS: Two non-consecutive 24-h recalls were conducted in convenience samples of 20 rural Mayan women and 20 urban students. Diversity scores were computed using three food-group systems.Variety and diversity scores and dietary origin and characteristics were compared between settings using independent t-test or Mann-Whitney-U-test. RESULTS: Dietary variety and diversity were generally greater in the urban sample when compared to the rural sample, depending on the number of days and food-group system used for evaluation.The diet was predominantly plant-based and composed of non-fortified food items in both areas.The rural diet was predominantly composed of traditional,non-processed foods. The urban diet was mostly based on non-traditional and processed items. CONCLUSION: Considerations of intervention strategies

  8. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Relationship between arsenic content of food and water applied for food processing.

    Science.gov (United States)

    Sugár, Eva; Tatár, Enikő; Záray, Gyula; Mihucz, Victor G

    2013-12-01

    As part of a survey conducted by the Central Agricultural Office of Hungary, 67 food samples including beverages were taken from 57 food industrial and catering companies, 75% of them being small and medium-sized enterprises (SMEs). Moreover, 40% of the SMEs were micro entities. Water used for food processing was simultaneously sampled. The arsenic (As) content of solid food stuff was determined by hydride generation atomic absorption spectrometry after dry ashing. Food stuff with high water content and water samples were analyzed by inductively coupled plasma mass spectrometry. The As concentration exceeded 10 μg/L in 74% of the water samples taken from SMEs. The As concentrations of samples with high water content and water used were linearly correlated. Estimated As intake from combined exposure to drinking water and food of the population was on average 40% of the daily lower limit of WHO on the benchmark dose for a 0.5% increased incidence of lung cancer (BMDL0.5) for As. Five settlements had higher As intake than the BMDL0.5. Three of these settlements are situated in Csongrád county and the distance between them is less than 55 km. The maximum As intake might be 3.8 μg/kg body weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Microbiologia de swabs retais e otológicos em carnívoros silvestres do zoológico do Parque Estadual de Dois Irmãos, Pernambuco

    Directory of Open Access Journals (Sweden)

    Débora Costa Viegas de Lima

    2012-02-01

    Full Text Available O estudo epidemiológico de patógenos em populações selvagens no ambiente in situ e ex situ é fundamental para implementação de programas de prevenção, controle e monitoramento de enfermidades e para elaboração de políticas públicas de saúde pública e animal. O estudo foi realizado no zoológico do Parque Estadual de Dois Irmãos no período de janeiro a julho de 2011 onde foram coletados swabs anais e otológicos referentes a 29 carnívoros silvestres cativos do zoológico. Dos swabs otológicos analisados, 1/29 (3,4% foi positivo para Malassezia pachy dermatis no exame direto. No exame microbiológico dos swabs otológicos, observou-se maior freqüência para bactérias do gênero Bacillus 16/29 (55,2%, seguida de Sta phylococcus 15/29 (51,7%, Escherichia coli 7/29 (24,1%, Streptobacillus 1/29 (3,4%, Micrococcus 1/29 (3,4% e Klebsiella 1/29 (3,4%. Com relação ao exame presuntivo para o gênero Salmonella a partir das amostras de swab retal, observou-se positividade para seis raposas (Cerdocyon thous e um guaxinim (Procyon cancrivorus. O isolamento de Salmonella spp. em C. thous e em P. cancrivorus indica um risco à saúde pública, principalmente para os profissionais do zoológico que trabalham diretamente com esses animais. Essa pesquisa reforça a importância da criação de estratégias de vigilância epidemiológica voltadas para a prevenção, controle e monitoramento de potenciais reservatórios de agentes etiológicos de doenças infecciosas e parasitárias no ambiente dos zoológicos.

  11. A Sensitive Assay for Virus Discovery in Respiratory Clinical Samples

    Science.gov (United States)

    de Vries, Michel; Deijs, Martin; Canuti, Marta; van Schaik, Barbera D. C.; Faria, Nuno R.; van de Garde, Martijn D. B.; Jachimowski, Loes C. M.; Jebbink, Maarten F.; Jakobs, Marja; Luyf, Angela C. M.; Coenjaerts, Frank E. J.; Claas, Eric C. J.; Molenkamp, Richard; Koekkoek, Sylvie M.; Lammens, Christine; Leus, Frank; Goossens, Herman; Ieven, Margareta; Baas, Frank; van der Hoek, Lia

    2011-01-01

    In 5–40% of respiratory infections in children, the diagnostics remain negative, suggesting that the patients might be infected with a yet unknown pathogen. Virus discovery cDNA-AFLP (VIDISCA) is a virus discovery method based on recognition of restriction enzyme cleavage sites, ligation of adaptors and subsequent amplification by PCR. However, direct discovery of unknown pathogens in nasopharyngeal swabs is difficult due to the high concentration of ribosomal RNA (rRNA) that acts as competitor. In the current study we optimized VIDISCA by adjusting the reverse transcription enzymes and decreasing rRNA amplification in the reverse transcription, using hexamer oligonucleotides that do not anneal to rRNA. Residual cDNA synthesis on rRNA templates was further reduced with oligonucleotides that anneal to rRNA but can not be extended due to 3′-dideoxy-C6-modification. With these modifications >90% reduction of rRNA amplification was established. Further improvement of the VIDISCA sensitivity was obtained by high throughput sequencing (VIDISCA-454). Eighteen nasopharyngeal swabs were analysed, all containing known respiratory viruses. We could identify the proper virus in the majority of samples tested (11/18). The median load in the VIDISCA-454 positive samples was 7.2 E5 viral genome copies/ml (ranging from 1.4 E3–7.7 E6). Our results show that optimization of VIDISCA and subsequent high-throughput-sequencing enhances sensitivity drastically and provides the opportunity to perform virus discovery directly in patient material. PMID:21283679

  12. A sensitive assay for virus discovery in respiratory clinical samples.

    Directory of Open Access Journals (Sweden)

    Michel de Vries

    Full Text Available In 5-40% of respiratory infections in children, the diagnostics remain negative, suggesting that the patients might be infected with a yet unknown pathogen. Virus discovery cDNA-AFLP (VIDISCA is a virus discovery method based on recognition of restriction enzyme cleavage sites, ligation of adaptors and subsequent amplification by PCR. However, direct discovery of unknown pathogens in nasopharyngeal swabs is difficult due to the high concentration of ribosomal RNA (rRNA that acts as competitor. In the current study we optimized VIDISCA by adjusting the reverse transcription enzymes and decreasing rRNA amplification in the reverse transcription, using hexamer oligonucleotides that do not anneal to rRNA. Residual cDNA synthesis on rRNA templates was further reduced with oligonucleotides that anneal to rRNA but can not be extended due to 3'-dideoxy-C6-modification. With these modifications >90% reduction of rRNA amplification was established. Further improvement of the VIDISCA sensitivity was obtained by high throughput sequencing (VIDISCA-454. Eighteen nasopharyngeal swabs were analysed, all containing known respiratory viruses. We could identify the proper virus in the majority of samples tested (11/18. The median load in the VIDISCA-454 positive samples was 7.2 E5 viral genome copies/ml (ranging from 1.4 E3-7.7 E6. Our results show that optimization of VIDISCA and subsequent high-throughput-sequencing enhances sensitivity drastically and provides the opportunity to perform virus discovery directly in patient material.

  13. DNA-based culture-independent analysis detects the presence of group a streptococcus in throat samples from healthy adults in Japan.

    Science.gov (United States)

    Kulkarni, Tejaswini; Aikawa, Chihiro; Nozawa, Takashi; Murase, Kazunori; Maruyama, Fumito; Nakagawa, Ichiro

    2016-10-11

    Group A Streptococcus (GAS; Streptococcus pyogenes) causes a range of mild to severe infections in humans. It can also colonize healthy persons asymptomatically. Therefore, it is important to study GAS carriage in healthy populations, as carriage of it might lead to subsequent disease manifestation, clonal spread in the community, and/or diversification of the organism. Throat swab culture is the gold standard method for GAS detection. Advanced culture-independent methods provide rapid and efficient detection of microorganisms directly from clinical samples. We investigated the presence of GAS in throat swab samples from healthy adults in Japan using culture-dependent and culture-independent methods. Two throat swab samples were collected from 148 healthy volunteers. One was cultured on selective medium, while total DNA extracted from the other was polymerase chain reaction (PCR) amplified with two GAS-specific primer pairs: one was a newly designed 16S rRNA-specific primer pair, the other a previously described V-Na + -ATPase primer pair. Although only 5 (3.4 %) of the 148 samples were GAS-positive by the culture-dependent method, 146 (98.6 %) were positive for the presence of GAS DNA by the culture-independent method. To obtain serotype information by emm typing, we performed nested PCR using newly designed emm primers. We detected the four different emm types in 25 (16.9 %) samples, and these differed from the common emm types associated with GAS associated diseases in Japan. The different emm types detected in the healthy volunteers indicate that the presence of unique emm types might be associated with GAS carriage. Our results suggest that culture-independent methods should be considered for profiling GAS in the healthy hosts, with a view to obtaining better understanding of these organisms. The GAS-specific primers (16S rRNA and V-Na + -ATPase) used in this study can be used to estimate the maximum potential GAS carriage in people.

  14. Crave, like, eat: determinants of food intake in a sample of children and adolescents with a wide range in body mass

    Directory of Open Access Journals (Sweden)

    Johannes Hofmann

    2016-09-01

    Full Text Available Obesity is heterogeneous condition with obese individuals displaying different eating patterns. Growing evidence suggests that there is a subgroup of obese adults that is marked by frequent and intense food cravings and addiction-like consumption of high-calorie foods. Little is known, however, about such a subgroup of obese individuals in childhood and adolescence. In the present study, a sample of children and adolescents with a wide range in body mass was investigated and trait food craving, liking for and intake of high- and low-calorie foods was measured. One-hundred and forty-two children and adolescents (51.4% female, n = 73; Mage = 13.7 years, SD = 2.25; MBMI-SDS = 1.26, SD = 1.50 completed the Food Cravings Questionnaire - Trait, then viewed pictures of high- and low-calorie foods and rated their liking for them, and subsequently consumed some of these foods in a bogus taste test. Contrary to expectations, higher body mass was associated with lower consumption of high-calorie foods. However, there was an interaction between body mass and trait food craving when predicting food consumption: in obese participants, higher trait food craving was associated with higher consumption of high-calorie foods and this association was not found in normal-weight participants. The relationship between trait food craving and high-calorie food consumption within obese individuals was mediated by higher liking for high-calorie foods (but not by liking for low-calorie foods. Thus, similar to adults, a subgroup of obese children and adolescents - characterized by high trait food craving - seems to exist, calling for specific targeted treatment strategies.

  15. Biophysical Evaluation of Food Decontamination Effects on Tissue and Bacteria

    DEFF Research Database (Denmark)

    Andersen, Ann Zahle; Duelund, Lars; Brewer, Jonathan

    2011-01-01

    Traditionally, the effects and efficiency of food surface decontamination processes, such as chlorine washing, radiation, or heating, have been evaluated by sensoric analysis and colony-forming unit (CFU) counts of surface swabs or carcass rinses. These methods suffice when determining probable...... consumer responses or meeting legislative contamination limits. However, in the often very costly, optimization process of a new method, more quantitative and unbiased results are invaluable. In this study, we employed a biophysical approach for the investigation of qualitative and quantitative changes...... that there are no contradictions between data obtained by either approach. However, the biophysical methods draw a much more nuanced picture of the effects and efficiency of the investigated decontamination method, revealing, e.g., an exponential dose/response relationship between SonoSteam® treatment time and changes in collagen...

  16. Healthy food choices are happy food choices : evidence from a real life sample using smartphone based assessments

    OpenAIRE

    Wahl, Deborah R.; Villinger, Karoline; König, Laura M.; Ziesemer, Katrin; Schupp, Harald T.; Renner, Britta

    2017-01-01

    Research suggests that "healthy" food choices such as eating fruits and vegetables have not only physical but also mental health benefits and might be a long-term investment in future well-being. This view contrasts with the belief that high-caloric foods taste better, make us happy, and alleviate a negative mood. To provide a more comprehensive assessment of food choice and well-being, we investigated in-the-moment eating happiness by assessing complete, real life dietary behaviour across ei...

  17. Lead in Danish Food-Stuffs

    DEFF Research Database (Denmark)

    Aarkrog, Asker; Solgaard, Per Bent; Fenger, J.

    1979-01-01

    A long-term study (1962-1976) of the Pb content of food has been performed using samples of Danish food substances collected annually at the Riso National Laboratory. Samples so far investigated are: 150 samples of dried milk from 7 factories; 500 samples of Danish cereals (spring and winter whea...

  18. Comparison of different sampling techniques and of different culture methods for detection of group B streptococcus carriage in pregnant women

    Directory of Open Access Journals (Sweden)

    Verhelst Rita

    2010-09-01

    Full Text Available Abstract Background Streptococcus agalactiae (group B streptococcus; GBS is a significant cause of perinatal and neonatal infections worldwide. To detect GBS colonization in pregnant women, the CDC recommends isolation of the bacterium from vaginal and anorectal swab samples by growth in a selective enrichment medium, such as Lim broth (Todd-Hewitt broth supplemented with selective antibiotics, followed by subculture on sheep blood agar. However, this procedure may require 48 h to complete. We compared different sampling and culture techniques for the detection of GBS. Methods A total of 300 swabs was taken from 100 pregnant women at 35-37 weeks of gestation. For each subject, one rectovaginal, one vaginal and one rectal ESwab were collected. Plating onto Columbia CNA agar (CNA, group B streptococcus differential agar (GBSDA (Granada Medium and chromID Strepto B agar (CA, with and without Lim broth enrichment, were compared. The isolates were confirmed as S. agalactiae using the CAMP test on blood agar and by molecular identification with tDNA-PCR or by 16S rRNA gene sequence determination. Results The overall GBS colonization rate was 22%. GBS positivity for rectovaginal sampling (100% was significantly higher than detection on the basis of vaginal sampling (50%, but not significantly higher than for rectal sampling (82%. Direct plating of the rectovaginal swab on CNA, GBSDA and CA resulted in detection of 59, 91 and 95% of the carriers, respectively, whereas subculturing of Lim broth yielded 77, 95 and 100% positivity, respectively. Lim broth enrichment enabled the detection of only one additional GBS positive subject. There was no significant difference between GBSDA and CA, whereas both were more sensitive than CNA. Direct culture onto GBSDA or CA (91 and 95% detected more carriers than Lim broth enrichment and subculture onto CNA (77%. One false negative isolate was observed on GBSDA, and three false positives on CA. Conclusions In

  19. Green Synthesis of Fluorescent Carbon Dots for Selective Detection of Tartrazine in Food Samples.

    Science.gov (United States)

    Xu, Hua; Yang, Xiupei; Li, Gu; Zhao, Chuan; Liao, Xiangjun

    2015-08-05

    A simple, economical, and green method for the preparation of water-soluble, high-fluorescent carbon quantum dots (C-dots) has been developed via hydrothermal process using aloe as a carbon source. The synthesized C-dots were characterized by atomic force microscope (AFM), transmission electron microscopy (TEM), fluorescence spectrophotometer, UV-vis absorption spectra as well as Fourier transform infrared spectroscopy (FTIR). The results reveal that the as-prepared C-dots were spherical shape with an average diameter of 5 nm and emit bright yellow photoluminescence (PL) with a quantum yield of approximately 10.37%. The surface of the C-dots was rich in hydroxyl groups and presented various merits including high fluorescent quantum yield, excellent photostability, low toxicity and satisfactory solubility. Additionally, we found that one of the widely used synthetic food colorants, tartrazine, could result in a strong fluorescence quenching of the C-dots through a static quenching process. The decrease of fluorescence intensity made it possible to determine tartrazine in the linear range extending from 0.25 to 32.50 μM, This observation was further successfully applied for the determination of tartrazine in food samples collected from local markets, suggesting its great potential toward food routine analysis. Results from our study may shed light on the production of fluorescent and biocompatible nanocarbons due to our simple and environmental benign strategy to synthesize C-dots in which aloe was used as a carbon source.

  20. Application of the WHO five keys of food safety to improve food ...

    African Journals Online (AJOL)

    Aim: To apply the WHO five keys of food safety in evidence based training programme for food vendors to improve the handling of street food. Methods: A total of 127 food vendors in Accra, the capital city of Ghana were sampled for interviews. Data collection from the vendors focused on (i) food handling practices (ii) ...

  1. A Decision-Making Model for Deterring Food Vendors from Selling Harmless Low-Quality Foods as High-Quality Foods to Consumers

    Directory of Open Access Journals (Sweden)

    Po-Yu Chen

    2017-01-01

    Full Text Available For certain types of foods, food vendors often label low-quality foods that are harmless to human health as foods of excellent quality and sell these falsely labeled products to consumers. Because this type of food poses no harm to human health, when public health units discover their act of false labeling or food adulteration, vendors are only penalized with a fine rather than having them assume criminal liability. Upon discovering vendors act of falsely labeling food, public health units typically punish the involved parties according to the extent of false labeling. Such static protective measure is ineffective. Instead, the extent of punishment should be based not only on the extent of false labeling, but also on the frequency of food sampling as well as the number of samples obtained for food inspections. Only through this dynamic approach can food adulteration or false labeling be effectively prevented. Adopting the standpoint of the public sector in food safety management, this study developed a mathematical model that facilitates discussion on the aforementioned problems. Furthermore, we discussed how the supply-demand environmental factors of the food market are influenced by the administrative means that the public health units have used to prevent food false labeling.

  2. Remifentanil maintains lower initial delayed nonmatching-to-sample accuracy compared to food pellets in male rhesus monkeys.

    Science.gov (United States)

    Hutsell, Blake A; Banks, Matthew L

    2017-12-01

    Emerging human laboratory and preclinical drug self-administration data suggest that a history of contingent abused drug exposure impairs performance in operant discrimination procedures, such as delayed nonmatching-to-sample (DNMTS), that are hypothesized to assess components of executive function. However, these preclinical discrimination studies have exclusively used food as the reinforcer and the effects of drugs as reinforcers in these operant procedures are unknown. The present study determined effects of contingent intravenous remifentanil injections on DNMTS performance hypothesized to assess 1 aspect of executive function, working memory. Daily behavioral sessions consisted of 2 components with sequential intravenous remifentanil (0, 0.01-1.0 μg/kg/injection) or food (0, 1-10 pellets) availability in nonopioid dependent male rhesus monkeys (n = 3). Remifentanil functioned as a reinforcer in the DNMTS procedure. Similar delay-dependent DNMTS accuracy was observed under both remifentanil- and food-maintained components, such that higher accuracies were maintained at shorter (0.1-1.0 s) delays and lower accuracies approaching chance performance were maintained at longer (10-32 s) delays. Remifentanil maintained significantly lower initial DNMTS accuracy compared to food. Reinforcer magnitude was not an important determinant of DNMTS accuracy for either remifentanil or food. These results extend the range of experimental procedures under which drugs function as reinforcers. Furthermore, the selective remifentanil-induced decrease in initial DNMTS accuracy is consistent with a selective impairment of attentional, but not memorial, processes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Molecular and epidemiological characterization of staphylococcal foodborne outbreak of Staphylococcus aureus harboring seg, sei, sem, sen, seo, and selu genes without production of classical enterotoxins.

    Science.gov (United States)

    Umeda, Kaoru; Nakamura, Hiromi; Yamamoto, Kaori; Nishina, Nobuko; Yasufuku, Kiyoshi; Hirai, Yuki; Hirayama, Teruo; Goto, Kaoru; Hase, Atsushi; Ogasawara, Jun

    2017-09-01

    Staphylococcal food poisoning is the result of consumption of food contaminated with staphylococcal enterotoxins (SEs) produced by Staphylococcus aureus. To date, 23 SEs and SE-like enterotoxins (SEls) have been described in the literature. They are divided into classical SEs (SEA-SEE) and new SE/SEls (SEG-SElX). Some have proved to be foodborne-inducible, but others remain unidentified. In May 2016, at an elderly group home in Osaka city, Japan, an outbreak from foodborne pathogens occurred among lunch party participants. Within 2h 30min to 4h 40min, 15 of 53 participants presented gastrointestinal symptoms of vomiting, diarrhea, and nausea. A subsequent laboratory investigation detected S. aureus from most stool samples from patients, several left-over food items, a kitchen swab, and hand swabs from two food handlers. Classical SEs was not detected from S. aureus isolates or left-over food items. From examination for the presence of SE/SEl genes of 20 kinds by PCR, seg, sei, sem, sen, seo, and selu genes were detected in almost all isolates. These isolates exhibited identical or closely related types by coagulase type (type VII), Sma I digested pulsed-field gel electrophoresis analysis and multi-locus sequence typing (MLST-CC45 lineage). These results suggest that the foodborne outbreak was caused by S. aureus harboring seg, sei, sem, sen, seo, and selu genes without production of classical SEs. Additionally, some S. aureus isolates from human nasal swabs and healthy human feces harboring seg, sei, sem, sen, seo, and selu genes without production of classical SEs were classified into CC45 lineage using MLST. These findings suggest new SE/SEls as a potential cause of foodborne outbreaks. Copyright © 2017. Published by Elsevier B.V.

  4. Comparison of R5 and G12 Antibody-Based ELISA Used for the Determination of the Gluten Content in Official Food Samples

    Directory of Open Access Journals (Sweden)

    Rupert Hochegger

    2015-11-01

    Full Text Available Celiac Disease (CD is one of the most common food intolerances. It comes along with serious damage of the mucosa in the small intestine and is caused by the storage proteins—termed “gluten”—of wheat, rye, barley and possibly oats. Sensitive individuals need to stick to a strict gluten-free diet. The gluten level in food products labeled as “gluten-free”, must not exceed 20 mg/kg. It is obvious that effective test methods are needed to accurately determine the gluten concentration in foods. The determination of the presence of gluten in foodstuffs is mainly done by means of an immunochemical method called ELISA (enzyme-linked immunosorbent assay. To check the suitability of a G12 antibody-based gluten detection kit for its use in official control systems a number of routine samples were tested in parallel with two different test kits, as would be done in a routine lab. The determination of the gluten content was performed on samples entering the official laboratory including samples from official control plans, commercially available and private samples to request gluten-free labels. The results obtained with the G12 antibody ELISA assay were comparable to the official R5 method. A validation of the two different methods was not part of this study.

  5. Iodine Contents in Baby Food Consumed in Japan

    Directory of Open Access Journals (Sweden)

    Yoshida M.

    2013-04-01

    Full Text Available To evaluate iodine intake in Japanese infants, iodine contents were determined in both commercial and homemade baby food samples consumed in Japan. Fifty-three samples of commercial bottled or retort baby food and 25 samples of homemade baby food for one day were collected and their iodine contents were determined by inductively coupled plasma mass spectrometry after an extraction with 0.5% tetramethylammonium hydroxide. Among the commercial baby food samples, 35 samples showed low iodine values ( 1000 ng/g wet weight. Significantly higher iodine values were observed in 15 samples composed of dishes cooked using kombu (a kind of kelp than other samples. Among the homemade baby food samples, 12 samples brought very low iodine intake (< 1- 24 μg/d, while 5 samples brought very high iodine intake (283-978 μg/d. These results indicate that intermittent high iodine baby food including dishes cooked using kombu contributes to sufficient iodine intake in Japanese infants.

  6. Ultrasensitive determination of formaldehyde in environmental waters and food samples after derivatization and using silver nanoparticle assisted SERS

    International Nuclear Information System (INIS)

    Ma, Pinyi; Wang, Di; Yang, Qingqing; Song, Daqian; Wang, Xinghua; Liang, Fanghui; Ding, Yaying; Yu, Yong; Gao, Dejiang

    2015-01-01

    A selective and ultrasensitive surface-enhanced Raman spectroscopy (SERS) method was developed for the determination of formaldehyde (HCHO) in environmental waters and food samples. It is based on derivatization of HCHO with 4-amino-5-hydrazino-3-mercapto-1,2,4-triazole (AHMT) with HCHO. One of the products of the derivative reaction, 6-mercapto-5-triazolo[4,3-b]-s-tetrazine (MTT), can be quantified by SERS at 832 cm −1 using silver nanoparticles (AgNPs) as substrates. The incubation time for derivatization, the volume of reagents and the mixing times were optimized. The peak areas of the SERS are linearly related to the concentration of HCHO in the 1 − 1,000 μg L −1 range, the limit of detection is 0.15 μg L −1 , and the limit of quantification is 0.45 μg L −1 . Recoveries obtained by analyzing two spiked samples of environmental water and two spiked food samples were in the range between 91.0 and 108.7 %. There is no significant difference between the results obtained by the present method and the liquid chromatographic method (Chinese industrial standard method, SN/T 1547-2011). (author)

  7. Methods for Recovering Microorganisms from Solid Surfaces Used in the Food Industry: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Perrine Gay-Perret

    2013-11-01

    Full Text Available Various types of surfaces are used today in the food industry, such as plastic, stainless steel, glass, and wood. These surfaces are subject to contamination by microorganisms responsible for the cross-contamination of food by contact with working surfaces. The HACCP-based processes are now widely used for the control of microbial hazards to prevent food safety issues. This preventive approach has resulted in the use of microbiological analyses of surfaces as one of the tools to control the hygiene of products. A method of recovering microorganisms from different solid surfaces is necessary as a means of health prevention. No regulation exists for surface microbial contamination, but food companies tend to establish technical specifications to add value to their products and limit contamination risks. The aim of this review is to present the most frequently used methods: swabbing, friction or scrubbing, printing, rinsing or immersion, sonication and scraping or grinding and describe their advantages and drawbacks. The choice of the recovery method has to be suitable for the type and size of the surface tested for microbiological analysis. Today, quick and cheap methods have to be standardized and especially easy to perform in the field.

  8. Fast Food Jobs. National Study of Fast Food Employment.

    Science.gov (United States)

    Charner, Ivan; Fraser, Bryna Shore

    A study examined employment in the fast-food industry. The national survey collected data from employees at 279 fast-food restaurants from seven companies. Female employees outnumbered males by two to one. The ages of those fast-food employees in the survey sample ranged from 14 to 71, with fully 70 percent being in the 16- to 20-year-old age…

  9. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  10. Evaluation of hygienic quality and labelling of fish distributed in public canteens of Northeast Italy

    Directory of Open Access Journals (Sweden)

    Mariachiara Armani

    2016-09-01

    Full Text Available Over the past few years, the demand for the introduction of fish products in public canteens (schools, hospitals and nursing-homes has grown due to their good nutritional proprieties. The particular health conditions and sensitivity of some groups of consumers exposes them to greater risks of food poisoning. It is therefore important to monitor the raw materials that end up in mass catering implementing strategies of mass catering control, both with self-monitoring strategies and with regular controls performed by the competent health authorities. The purpose of this study is to assess the overall quality of seafood dealt out from public catering services located in Northeast Italy. In this paper we illustrate the results of microbiological analysis performed on 135 fish samples (58% of samples were raw fishes, 27% cooked fishes, 6% raw fish products, 9% cooked fish products and species identification performed on 102 fish samples. Additionally, 135 environmental swabs were collected to determine the effectiveness of cleaning and sanitation of food contact (cutting boards, cooking equipment and food processing surfaces and non-contact (refrigerator wall and handle, tap lever surfaces. Of raw seafood samples, 24% had total aerobic mesophilic bacteria count >105 CFU/g and for Enterobacteriaceae the faecal contamination was excluded since no Salmonella spp. and Escherichia coli were isolated. Just 3.8% of raw seafood samples resulted positive for Listeria monocytogenes. The results of swab samples of cooking utensils and surfaces showed that sanitation practices should be improved. Molecular analysis for fish species identification revealed a mislabelling for 25% of sampled fishes. The results of this survey can provide valuable information for monitoring and surveillance programmes for the control of quality of fish and fish products.

  11. A lab-on-a-chip system with integrated sample preparation and loop-mediated isothermal amplification for rapid and quantitative detection of Salmonella spp. in food samples

    DEFF Research Database (Denmark)

    Sun, Yi; Than Linh, Quyen; Hung, Tran Quang

    2015-01-01

    was capable to detect Salmonella at concentration of 50 cells per test within 40 min. The simple design, together with high level of integration, isothermal amplification, and quantitative analysis of multiple samples in short time will greatly enhance the practical applicability of the LOC system for rapid...... amplification (LAMP) for rapid and quantitative detection of Salmonella spp. in food samples. The whole diagnostic procedures including DNA isolation, isothermal amplification, and real-time detection were accomplished in a single chamber. Up to eight samples could be handled simultaneously and the system...... and usually take a few hours to days to complete. In response to the demand for rapid on line or at site detection of pathogens, in this study, we describe for the first time an eight-chamber lab-on-a-chip (LOC) system with integrated magnetic beads-based sample preparation and loop-mediated isothermal...

  12. Validation of High Resolution Melting Analysis (HRM of the Amplified ITS2 Region for the Detection and Identification of Yeasts from Clinical Samples: Comparison with Culture and MALDI-TOF Based Identification.

    Directory of Open Access Journals (Sweden)

    Hans Duyvejonck

    Full Text Available Candida species are known as opportunistic pathogens, and a possible cause of invasive infections. Because of their species-specific antimycotic resistance patterns, reliable techniques for their detection, quantification and identification are needed. We validated a DNA amplification method for direct detection of Candida spp. from clinical samples, namely the ITS2-High Resolution Melting Analysis (direct method, by comparing it with a culture and MALDI-TOF Mass Spectrometry based method (indirect method to establish the presence of Candida species in three different types of clinical samples.A total of 347 clinical samples, i.e. throat swabs, rectal swabs and vaginal swabs, were collected from the gynaecology/obstetrics, intensive care and haematology wards at the Ghent University Hospital, Belgium. For the direct method, ITS2-HRM was preceded by NucliSENS easyMAG DNA extraction, directly on the clinical samples. For the indirect method, clinical samples were cultured on Candida ID and individual colonies were identified by MALDI-TOF.For 83.9% of the samples there was complete concordance between both techniques, i.e. the same Candida species were detected in 31.1% of the samples or no Candida species were detected in 52.8% of the samples. In 16.1% of the clinical samples, discrepant results were obtained, of which only 6.01% were considered as major discrepancies. Discrepancies occurred mostly when overall numbers of Candida cells in the samples were low and/or when multiple species were present in the sample.Most of the discrepancies could be decided in the advantage of the direct method. This is due to samples in which no yeast could be cultured whereas low amounts could be detected by the direct method and to samples in which high quantities of Candida robusta according to ITS2-HRM were missed by culture on Candida ID agar. It remains to be decided whether the diagnostic advantages of the direct method compensate for its disadvantages.

  13. Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction.

    Science.gov (United States)

    Deng, Fenfang; Yu, Hong; Pan, Xinhong; Hu, Guoyuan; Wang, Qiqin; Peng, Rongfei; Tan, Lei; Yang, Zhicong

    2018-02-23

    This paper demonstrated the development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of five glycopeptide antibiotics in food and biological samples. The target glycopeptide antibiotics were isolated from the samples by solvent extraction, and the extracts were cleaned with a tandem solid-phase extraction step using mixed strong cation exchange and hydrophilic/lipophilic balance cartridges. Subsequently, the analytes were eluted with different solvents, and then quantified by UHPLC-MS/MS in the positive ionization mode with multiple reaction monitoring. Under optimal conditions, good linear correlations were obtained for the five glycopeptide antibiotics in the concentration range of 1.0 μg/L to 20.0 μg/L, and with linear correlation coefficients >0.998. Employing this method, the target glycopeptide antibiotics in food and biological samples were identified with a recovery of 83.0-102%, and a low quantitation limit of 1.0 μg/kg in food and 2.0 μg/L in biological samples with low matrix effects. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Focusing and non-focusing modulation strategies for the improvement of on-line two-dimensional hydrophilic interaction chromatography × reversed phase profiling of complex food samples.

    Science.gov (United States)

    Montero, Lidia; Ibáñez, Elena; Russo, Mariateresa; Rastrelli, Luca; Cifuentes, Alejandro; Herrero, Miguel

    2017-09-08

    Comprehensive two-dimensional liquid chromatography (LC × LC) is ever gaining interest in food analysis, as often, food-related samples are too complex to be analyzed through one-dimensional approaches. The use of hydrophilic interaction chromatography (HILIC) combined with reversed phase (RP) separations has already been demonstrated as a very orthogonal combination, which allows attaining increased resolving power. However, this coupling encompasses different analytical challenges, mainly related to the important solvent strength mismatch between the two dimensions, besides those common to every LC × LC method. In the present contribution, different strategies are proposed and compared to further increase HILIC × RP method performance for the analysis of complex food samples, using licorice as a model sample. The influence of different parameters in non-focusing modulation methods based on sampling loops, as well as under focusing modulation, through the use of trapping columns in the interface and through active modulation procedures are studied in order to produce resolving power and sensitivity gains. Although the use of a dilution strategy using sampling loops as well as the highest possible first dimension sampling rate allowed significant improvements on resolution, focusing modulation produced significant gains also in peak capacity and sensitivity. Overall, the obtained results demonstrate the great applicability and potential that active modulation may have for the analysis of complex food samples, such as licorice, by HILIC × RP. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. 21 CFR 211.170 - Reserve samples.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Reserve samples. 211.170 Section 211.170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL... of deterioration unless visual examination would affect the integrity of the reserve sample. Any...

  16. Magnetically separable polymer (Mag-MIP) for selective analysis of biotin in food samples.

    Science.gov (United States)

    Uzuriaga-Sánchez, Rosario Josefina; Khan, Sabir; Wong, Ademar; Picasso, Gino; Pividori, Maria Isabel; Sotomayor, Maria Del Pilar Taboada

    2016-01-01

    This work presents an efficient method for the preparation of magnetic nanoparticles modified with molecularly imprinted polymers (Mag-MIP) through core-shell method for the determination of biotin in milk food samples. The functional monomer acrylic acid was selected from molecular modeling, EGDMA was used as cross-linking monomer and AIBN as radical initiator. The Mag-MIP and Mag-NIP were characterized by FTIR, magnetic hysteresis, XRD, SEM and N2-sorption measurements. The capacity of Mag-MIP for biotin adsorption, its kinetics and selectivity were studied in detail. The adsorption data was well described by Freundlich isotherm model with adsorption equilibrium constant (KF) of 1.46 mL g(-1). The selectivity experiments revealed that prepared Mag-MIP had higher selectivity toward biotin compared to other molecules with different chemical structure. The material was successfully applied for the determination of biotin in diverse milk samples using HPLC for quantification of the analyte, obtaining the mean value of 87.4% recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Uranium analysis in some food samples collected from Bathinda area of Punjab, India

    Science.gov (United States)

    Kumar, Mukesh; Prasher, Sangeeta; Singh, Surinder

    2009-07-01

    To strengthen the radiation protection infrastructure in Bathinda, the uranium concentration in daily diet of the residents has been measured and its associated radiation risks were estimated for the adult population. Food samples were collected from major cancer prone areas of the district, from which daily diets were prepared. These diet samples were analyzed using fission track technique. The measured values of the uranium content were found to vary from 0.38 mBq/g in mustard seeds to 4.60 mBq/g in wheat. In case of milk the uranium content is found to vary from 28.57-213.36 mBq/ℓ with mean concentration of 61.35 mBq/ℓ. This leads to a daily dietary intake of 0.90 Bq/day. The measured value of 0.90 Bq d-1, contributes to 1.12 mSv to the cumulative effective dose to the population. This dose is much large than the International Commission for Radiological Protection (ICRP) annual effective dose limit of 1 mSv for the general public [1]. Therefore, it would pose significant health hazard.

  18. The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.

    Science.gov (United States)

    Pugajeva, Iveta; Rozentale, Irina; Viksna, Arturs; Bartkiene, Elena; Bartkevics, Vadims

    2016-12-01

    Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Simulation of surge and swab pressures in well drilling operations; Simulacao do problema de 'surge' e 'swab' em atividades de perfuracao de pocos de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Fernando T.G.M.C. de; Kimura, Hudson Faglioni; Ramalho, Vanessa; Negrao, Cezar O. Ribeiro; Junqueira, Silvio L.M. [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Martins, Andre Leibsohn [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The movements of the well drilling pipe, known as trips, cause variations in the well inner pressure. When the pipe is moving downwards, in an operation called 'running', the pressure increases and is known as surge pressure and, when it is moving upwards, in an operation called 'pulling', the pressure decreases and it is so called a swab pressure. The study of this phenomenon is of great importance not only due to financial reasons but also for the determination of speeds and accelerations which should be used in running and pulling operations. Among the researchers have studied this problem, Fontenot and Clark are two of the most important. They formulated the problem solution through considerations about the friction factor. The present work's target is to develop a computational program which allows the calculus of those pressures, according to previous investigations and models found in the literature and for different types of fluids as well, such as Bingham fluid and Power Law fluid. (author)

  20. Food and farm products surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Poston, T.M.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the radiological analyses performed on food and farm samples collected during 1994. The food and farm sampling design addresses the potential influence of Hanford Site releases. Details of the sampling design and radionuclides analyzed are included in this section.

  1. Food and farm products surveillance

    International Nuclear Information System (INIS)

    Poston, T.M.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the radiological analyses performed on food and farm samples collected during 1994. The food and farm sampling design addresses the potential influence of Hanford Site releases. Details of the sampling design and radionuclides analyzed are included in this section

  2. Neighborhood fast food restaurants and fast food consumption: A national study

    OpenAIRE

    Richardson, Andrea S; Boone-Heinonen, Janne; Popkin, Barry M; Gordon-Larsen, Penny

    2011-01-01

    Abstract Background Recent studies suggest that neighborhood fast food restaurant availability is related to greater obesity, yet few studies have investigated whether neighborhood fast food restaurant availability promotes fast food consumption. Our aim was to estimate the effect of neighborhood fast food availability on frequency of fast food consumption in a national sample of young adults, a population at high risk for obesity. Methods We used national data from U.S. young adults enrolled...

  3. A simple method for determination of carmine in food samples based on cloud point extraction and spectrophotometric detection.

    Science.gov (United States)

    Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz

    2015-01-01

    In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Are Food Advertisements Promoting More Unhealthy Foods and Beverages over Time? Evidence from Three Swedish Food Magazines, 1995-2014.

    Science.gov (United States)

    Håkansson, Andreas

    2017-01-01

    Unhealthy food in advertising has been suggested as a mediator for the increase in diet-related illness. This study quantitatively investigates changes in food advertising between 1995 and 2014 in terms of food categories promoted, macronutrient content, and percentage of foods classified as heathy or unhealthy from a sample of 7,199 ads from three Swedish food magazines. With the exception of increased alcoholic beverage and decreased carbohydrate-rich-food promotion, no monotonic trends of increasingly unhealthy food advertisement are found. From these findings, it is argued that food magazine advertising is not a mediator of the adverse dietary trend.

  5. Implementation of Competitive Food and Beverage Standards in a Sample of Massachusetts Schools: The NOURISH Study (Nutrition Opportunities to Understand Reforms Involving Student Health).

    Science.gov (United States)

    Hoffman, Jessica A; Rosenfeld, Lindsay; Schmidt, Nicole; Cohen, Juliana F W; Gorski, Mary; Chaffee, Ruth; Smith, Lauren; Rimm, Eric B

    2015-08-01

    During 2012, Massachusetts adopted comprehensive school competitive food and beverage standards that closely align with Institute of Medicine recommendations and Smart Snacks in School national standards. We examined the extent to which a sample of Massachusetts middle schools and high schools sold foods and beverages that were compliant with the state competitive food and beverage standards after the first year of implementation, and complied with four additional aspects of the regulations. Observational cohort study with data collected before implementation (Spring 2012) and 1 year after implementation (Spring 2013). School districts (N=37) with at least one middle school and one high school participated. Percent of competitive foods and beverages that were compliant with Massachusetts standards and compliance with four additional aspects of the regulations. Data were collected via school site visits and a foodservice director questionnaire. Multilevel models were used to examine change in food and beverage compliance over time. More products were available in high schools than middle schools at both time points. The number of competitive beverages and several categories of competitive food products sold in the sample of Massachusetts schools decreased following the implementation of the standards. Multilevel models demonstrated a 47-percentage-point increase in food and 46-percentage-point increase in beverage compliance in Massachusetts schools from 2012 to 2013. Overall, total compliance was higher for beverages than foods. This study of a group of Massachusetts schools demonstrated the feasibility of schools making substantial changes in response to requirements for healthier competitive foods, even in the first year of implementation. Copyright © 2015 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  6. Sampling And Identifying Of Mould In The Library Building

    Directory of Open Access Journals (Sweden)

    Abdul Wahab Suriani Ngah

    2016-01-01

    Full Text Available Despite the growing concern over mould and fungi infestations on library building, little has been reported in the literature on the development of an objective tool and criteria for measuring and characterising the mould and fungi. In this paper, an objective based approach to mould and fungi growth assessment using various sampling techniques and its identification using microscopic observation are proposed. This study involved three library buildings of Higher Institution Educational in Malaysia for data collection purpose and study of mould growth. The mould sampling of three libraries was collected using Coriolis air sampler, settling plate air sampling using Malt Extract Agar (MEA, IAQ MOLD Alexeter IAQ-Pro Asp/Pen® Test and swab sampling techniques. The IAQ MOLD Alexeter IAQ-Pro Asp/Pen® Test and traditional method technique identified various mould species immediately on the site, and the microscopic observation identifies common types of the mould such as Aspergillus, Penicillium and Stachybotrys’s. The sample size and particular characteristics of each library will result in the mould growth pattern and finding.

  7. A novel derivation of a within-batch sampling plan based on a Poisson-gamma model characterising low microbial counts in foods.

    Science.gov (United States)

    Gonzales-Barron, Ursula; Zwietering, Marcel H; Butler, Francis

    2013-02-01

    This study proposes a novel step-wise methodology for the derivation of a sampling plan by variables for food production systems characterised by relatively low concentrations of the inspected microorganism. After representing the universe of contaminated batches by modelling the between-batch and within-batch variability in microbial counts, a tolerance criterion defining batch acceptability (i.e., up to a tolerance percentage of the food units having microbial concentrations lower or equal to a critical concentration) is established to delineate a limiting quality contour that separates satisfactory from unsatisfactory batches. The problem consists then of finding the optimum decision criterion - arithmetic mean of the analytical results (microbiological limit, m(L)) and the sample size (n) - that satisfies a pre-defined level of confidence measured on the samples' mean distributions from all possible true within-batch distributions. This is approached by obtaining decision landscape curves representing collectively the conditional and joint producer's and consumer's risks at different microbiological limits along with confidence intervals representing uncertainty due to the propagated between-batch variability. Whilst the method requires a number of risk management decisions to be made such as the objective of the sampling plan (GMP-based or risk-based), the modality of derivation, the tolerance criterion or level of safety, and the statistical level of confidence, the proposed method can be used when past monitoring data are available so as to produce statistically-sound dynamic sampling plans with optimised efficiency and discriminatory power. For the illustration of Enterobacteriaceae concentrations on Irish sheep carcasses, a sampling regime of n=10 and m(L)=17.5CFU/cm(2) is recommended to ensure that the producer has at least a 90% confidence of accepting a satisfactory batch whilst the consumer at least a 97.5% confidence that a batch will not be

  8. A simultaneous derivatization of 3-monochloropropanediol and 1,3-dichloropropane with hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate at room temperature for efficient analysis of food sample analysis.

    Science.gov (United States)

    Lee, Bai Qin; Wan Mohamed Radzi, Che Wan Jasimah Bt; Khor, Sook Mei

    2016-02-05

    This paper reports the application of hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate (HMDS-TMSOTf) for the simultaneous silylation of 3-monochloro-1,2-propanediol (3-MCPD) and 1,3-dicholoropropanol (1,3-DCP) in solid and liquid food samples. 3-MCPD and 1,3-DCP are chloropropanols that have been established as Group 2B carcinogens in clinical testing. They can be found in heat-processed food, especially when an extended high-temperature treatment is required. However, the current AOAC detection method is time-consuming and expensive. Thus, HMDS-TMSOTf was used in this study to provide a safer, and cost-effective alternative to the HFBI method. Three important steps are involved in the quantification of 3-MCPD and 1,3-DCP: extraction, derivatization and quantification. The optimization of the derivatization process, which involved focusing on the catalyst volume, derivatization temperature, and derivatization time was performed based on the findings obtained from both the Box-Behnken modeling and a real experimental set up. With the optimized conditions, the newly developed method was used for actual food sample quantification and the results were compared with those obtained via the standard AOAC method. The developed method required less samples and reagents but it could be used to achieve lower limits of quantification (0.0043mgL(-1) for 1,3-DCP and 0.0011mgL(-1) for 3-MCPD) and detection (0.0028mgL(-1) for 1,3-DCP and 0.0008mgL(-1) for 3-MCPD). All the detected concentrations are below the maximum tolerable limit of 0.02mgL(-1). The percentage of recovery obtained from food sample analysis was between 83% and 96%. The new procedure was validated with the AOAC method and showed a comparable performance. The HMDS-TMSOTf derivatization strategy is capable of simultaneously derivatizing 1,3-DCP and 3-MCPD at room temperature, and it also serves as a rapid, sensitive, and accurate analytical method for food samples analysis. Copyright © 2015 Elsevier B

  9. 21 CFR 1.90 - Notice of sampling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Notice of sampling. 1.90 Section 1.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GENERAL ENFORCEMENT REGULATIONS Imports and Exports § 1.90 Notice of sampling. When a sample of an article offered for import has...

  10. Contamination of food samples from Malaysia with polychlorinated dibenzo-p-dioxins and dibenzofurans and estimation of human intake.

    Science.gov (United States)

    Leong, Yin-Hui; Chiang, Pui-Nyuk; Jaafar, Hajjaj Juharullah; Gan, Chee-Yuen; Majid, Mohamed Isa Abdul

    2014-04-01

    A total of 126 food samples, categorised into three groups (seafood and seafood products, meat and meat products, as well as milk and dairy products) from Malaysia were analysed for polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). The concentration of PCDD/Fs that ranged from 0.16 to 0.25 pg WHO05-TEQ g(-1) fw was found in these samples. According to the food consumption data from the Global Environment Monitoring System (GEMS) of the World Health Organization (WHO), the dietary exposures to PCDD/F from seafood and seafood products, meat and meat products, as well as milk and dairy products for the general population in Malaysia were 0.064, 0.183 and 0.736 pg WHO05-TEQ kg(-1) bw day(-1), respectively. However, the exposure was higher in seafood and seafood products (0.415 pg WHO05-TEQ kg(-1) bw day(-1)) and meat and meat products (0.317 pg WHO05-TEQ kg(-1) bw day(-1)) when the data were estimated using the Malaysian food consumption statistics. The lower exposure was observed in dairy products with an estimation of 0.365 pg WHO05-TEQ kg(-1) bw day(-1). Overall, these dietary exposure estimates were much lower than the tolerable daily intake (TDI) as recommended by WHO. Thus, it is suggested that the dietary exposure to PCDD/F does not represent a risk for human health in Malaysia.

  11. Does food aid disrupt local food market?

    OpenAIRE

    Ferrière, Nathalie; Suwa-Eisenmann, Akiko

    2014-01-01

    This paper analyses empirically the impact of food aid on production, sales and purchases. We estimate the discrete choice and the level choice using the Ethiopian rural household survey. The panel dimension allows us to deal with food aid selection. Running a panel Tobit with sample selection and endogeneity we find that food aid reduces the probability of being a producer. It increases the one of being a seller and decreases the one of being a buyer only after 2004 that corresponds to chang...

  12. The use of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of toxic and essential elements in different types of food samples

    Science.gov (United States)

    Voica, C.; Dehelean, A.; Kovacs, M. H.

    2012-02-01

    Food is the primary source of essential elements for humans and it is an important source of exposure to toxic elements. In this context, levels of essential and toxic elements must be determined routinely in consumed food products. The content of trace elements (As, Pb, Cu, Cd, Zn, Sn, Hg) in different types of food samples (e.g. rice, bread, sugar, cheese, milk, butter, wheat, coffee, chocolate, biscuits pasta, etc.) was determined, using inductively coupled plasma mass spectrometry (ICP-MS). Trace element contents in some foods were higher than maximum permissible levels of toxic metals in human food (Cd in bread, Zn in cheese, Cu in coffee, Hg in carrots and peppers).

  13. Monitoring occurrence and persistence of Listeria monocytogenes in foods and food processing environments in the Republic of Ireland

    Directory of Open Access Journals (Sweden)

    Dara eLeong

    2014-08-01

    Full Text Available Although rates of listeriosis are low in comparison to other foodborne pathogenic illnesses, listeriosis poses a significant risk to human health as the invasive form can have a mortality rate as high as 30%. Food processors, especially those who produce ready-to-eat products, need to be vigilant against Listeria monocytogenes, the causative pathogen of listeriosis, and as such, the occurrence of L. monocytogenes in food and in the food processing environment needs to be carefully monitored. To examine the prevalence and patterns of contamination in food processing facilities in Ireland, 48 food processors submitted 8 samples every 2 months from March 2013 to March 2014 to be analyzed for L. monocytogenes. No positive samples were detected for 38% of the processing facilities tested. Isolates found at the remaining 62% of facilities were characterized by serotyping and Pulsed Field Gel Electrophoresis (PFGE. A general L. monocytogenes prevalence of 4.6% was seen in all samples analyzed with similar rates seen in food and environmental samples. Differences in prevalence were seen across different food processors, food sectors, sampling months etc. and PFGE analysis allowed for the examination of contamination patterns and for the identification of several persistent strains. Seven of the food processing facilities tested showed contamination with persistent strains and evidence of bacterial transfer from the processing environment to food (the same pulsotype found in both was seen in four of the food processing facilities tested.

  14. Monitoring occurrence and persistence of Listeria monocytogenes in foods and food processing environments in the Republic of Ireland.

    Science.gov (United States)

    Leong, Dara; Alvarez-Ordóñez, Avelino; Jordan, Kieran

    2014-01-01

    Although rates of listeriosis are low in comparison to other foodborne pathogenic illness, listeriosis poses a significant risk to human health as the invasive form can have a mortality rate as high as 30%. Food processors, especially those who produce ready-to-eat (RTE) products, need to be vigilant against Listeria monocytogenes, the causative pathogen of listeriosis, and as such, the occurrence of L. monocytogenes in food and in the food processing environment needs to be carefully monitored. To examine the prevalence and patterns of contamination in food processing facilities in Ireland, 48 food processors submitted 8 samples every 2 months from March 2013 to March 2014 to be analyzed for L. monocytogenes. No positive samples were detected at 38% of the processing facilities tested. Isolates found at the remaining 62% of facilities were characterized by serotyping and Pulsed Field Gel Electrophoresis (PFGE). A general L. monocytogenes prevalence of 4.6% was seen in all samples analyzed with similar rates seen in food and environmental samples. Differences in prevalence were seen across different food processors, food sectors, sampling months etc. and PFGE analysis allowed for the examination of contamination patterns and for the identification of several persistent strains. Seven of the food processing facilities tested showed contamination with persistent strains and evidence of bacterial transfer from the processing environment to food (the same pulsotype found in both) was seen in four of the food processing facilities tested.

  15. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry

    International Nuclear Information System (INIS)

    Lin Zhichao; Wu Zhongyu

    2009-01-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of 210 Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  16. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry.

    Science.gov (United States)

    Lin, Zhichao; Wu, Zhongyu

    2009-05-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of (210)Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  17. Food Technology. Specification for Irradiated Food

    International Nuclear Information System (INIS)

    2007-01-01

    This Ghana Standard specifies the requirements and methods of sampling and testing for foods processed by irradiation for sprout inhibition, insect disinfestation, microbial decontamination, delaying ripening, shelf-life extension and general phytosanitary treatment. The absorbed dose range covered by this guide is between 0.2kGy and 10kGy. The practical minimum or maximum dose of a treatment may be lower or higher than this range, depending on the purpose of irradiation and the radiation tolerance of the particular type of food. This standard does not apply to foods exposed to radiation imparted by measuring instruments used for inspection purposes

  18. Evaluation of the efficacy of real-time polymerase chain reaction for the routine early detection of Pseudomonas aeruginosa in cystic fibrosis sputum and throat swab specimens.

    LENUS (Irish Health Repository)

    Logan, Catriona

    2012-02-01

    A longitudinal study of 2099 sputa and throat swabs received from 183 pediatric cystic fibrosis patients over a 29-month period was used to evaluate the efficacy of real-time polymerase chain reaction (PCR) for the early detection of Pseudomonas aeruginosa as compared to microbiologic culture. Real-time PCR resulted in an increased number of specimens identified as P. aeruginosa positive. The sensitivity of culture was 82% (373\\/453) and of PCR was 93% (420\\/453) when considering both positive culture and PCR results as true positives. Of the 80 specimens identified as PCR positive\\/culture negative for P. aeruginosa, the subsequent patient sample in 32.5% (26\\/80) of specimens concerned was identified as P. aeruginosa culture positive, suggesting that PCR has the potential to detect P. aeruginosa earlier than the microbiologic culture. Real-time PCR analysis found no evidence of the Liverpool and Manchester epidemic P. aeruginosa strains in the cohort examined. The findings of this study highlight the importance of specimen collection protocols to ensure that adequate samples are received at the laboratory for testing, thereby minimizing the potential for reporting of false-negative P. aeruginosa culture results.

  19. Assessment of the microbial parameters along the production phases at a dairy plant

    Directory of Open Access Journals (Sweden)

    Angelovski Ljupco

    2012-01-01

    Full Text Available The main objective of this paper was to detect the prevalence of pathogenic bacteria (Listeria monocytogenes, Campylobacter spp., Salmonella spp., Staphylococcus aureus and Escherichia coli in raw milk, to assess the hygiene parameters during the milk processing and to evaluate the safety of the fi nal dairy products using standard ISO methods. Staphylococcus aureus showed highest prevalence of the pathogen microorganisms (85%, followed by Escherichia coli (46% and Listeria monocytogenes (9.8 in bulk tank milk samples. Campylobacter spp. and Salmonella spp. were not detected in any of the tested samples.The swab samples taken from employees and working surfaces, water samples and pasteurized milk samples detected inadequate sanitary procedures during the phase of milk processing. Analysis of the swabs from employees hands revealed 1 positive sample for enumeration for Enterobacteriaceae and 7 samples with higher total viable count that did not comply withthe legislative, while the analysis of the swabs from working surfaces detected 5 samples positive for Enterobacteriaceae and 4 samples with higher total viable count that did not comply with the same legislative. The analysis of the water samples detected 2 samples with higher total viable count on 22°C, 2 samples for total viable count on 37°C and 1 sample for coliform bacteria that did not comply with the national legislative. None of the samples showed presence of Pseudomonas aeruginosa, Escherichia coli, sulphite reducing clostridia and intestinal enterococci. The analysis ofthe pasteurized milk confi rmed 3 samples with presence of Enterobacteriacae, 1 sample for coagulase-positive staphylococci and 2 samples with high total viable count at 30°C that did not comply with the national legislative. The analysis of fermented milk products and cheese samples confirmed the need for immediate corective measures and subsequently, improved sanitation procedures. The testing detected 9 samples of

  20. On-farm comparisons of different cleaning protocols in broiler houses.

    Science.gov (United States)

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  1. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hong-geller, Elizabeth [Los Alamos National Laboratory; Valdez, Yolanda E [Los Alamos National Laboratory; Shou, Yulin [Los Alamos National Laboratory; Yoshida, Thomas M [Los Alamos National Laboratory; Marrone, Babetta L [Los Alamos National Laboratory; Dunbar, John [Los Alamos National Laboratory

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  2. EVALUATION OF THE DISINFECTION EFFECTIVENESS AT MEAT PROCESSING BY THE TWO METHODS

    Directory of Open Access Journals (Sweden)

    Simona Kunová,Miroslava Kačániová

    2015-06-01

    Full Text Available The aim of this article was the control of disinfection in selected meat processing-plant by two methods – swabbing method and The 3M™ Petrifilm™ plates. Samples were collected within three months (September, October, November 2014. Together 54 samples selected surfaces were collected. Each month six samples were collected using imprint method with Petrifilm plates on total count of microorganisms, 6 samples using imprint method with Petrifilm plates on the number of coliforms and 6 samples using sterile swab method. Samples were collected from the workbench, conveyor belt, cutting blades, meat grinder, wall and knife. Total viable counts (TVC and coliform bacteria (CB were determined in samples. The values of TVC in September obtained by swabbing method were higher than allowable limit in sample no. 1 (3.70×102 CFU.cm-2 and in sample no. 4 (3.35×101 KTJ.cm-2. The values of TVC obtained by Petrifilm plates were lower than 10 CFU.cm-2 in all samples. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm-2 in all samples, CB obtained by swabbing method was 1.6×101 CFU.cm-2 in sample no. 6. Values of TVC obtained in October by Petrifilm plates and also by swabbing method were higher than permissible limit (< 10 CFU.cm-2 in sample no. 2 and sample no. 4. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm-2 in all samples, CB obtained by swabbing method was 3,65×101 CFU.cm-2 in sample no. 3, value of CB obtained by swab method in sample no. 3 does not meet requirements of internal company standards. Values of TVC obtained in November by Petrifilm plates were lower than 10 CFU.cm-2 in all samples. TVC otained by swab method were 1,25×101 CFU.cm-2 in sample no. 3 and 3,25×101 CFU.cm-2 in sample no. 4. Samples were not in accordance with requirements of internal company standards. Values of CB obtained in November by Petrifilm plates and by swabbing method were after disinfection lower than 1 CFU.cm-2 in all

  3. Cesium-137 in various Chicago foods

    International Nuclear Information System (INIS)

    Karttunen, J.O.

    1979-01-01

    Since April 1961, the 137 Cs and potassium content of the Chicago portion of the Tri-City Diet Sampling Program has been determined in bulk food samples by gamma-ray spectrometry using a 4'' x 4'' NaI (TI) crystal. Each variety of food (all fresh vegetables, all fresh fruit, etc.) is composited before measurement, and each sample is counted 400 to 1000 minutes. From these measurements composite daily and yearly food intakes are obtained. The results for the October 1978 semi-annual sampling are tabulated

  4. Monitoring radioactivity in food and actions of the Ministry in charge of food

    International Nuclear Information System (INIS)

    Grastilleur, Ch.

    2010-01-01

    French ministry of food, agriculture and fisheries (general directorate for food) is involved in all aspects of food safety and food controls As such, MAAP guarantees both the quality and safety of food products radioactivity controls in food participate to this global aim. Since 1987 and following the accident on Tchernobyl nuclear plant, regulations and monitoring-control programmes have been implemented by MAPP, mainly based on Cs 134 and 137 and Sr 90 researches in raw products such as game, milk and dairy products and honey A new monitoring and control programme has been implemented as from 2009, with the help of IRSN and thanks to the work on management during post-accidental phases initiated in 2005 by ASN. Mainly the activity of Cs is determined but also other parameters are measured such as Ca, K and l 131 activities in the samples analysed by IRSN. In 2009, 812 samples were programmed and all of them have proven to be conform. During the year 2010, 725 samples will be collected, Global exposure to radioactivity in France is estimated at 4000 μSv per year, food and water contributing to 6% (that is about 250 μSv) mainly due to K and Ca (natural radioactive components of the regime). (author)

  5. Food adulteration analysis without laboratory prepared or determined reference food adulterant values.

    Science.gov (United States)

    Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A

    2014-04-01

    Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Magnetic stirrer induced dispersive ionic-liquid microextraction for the determination of vanadium in water and food samples prior to graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Naeemullah; Kazi, Tasneem Gul; Tuzen, Mustafa

    2015-04-01

    A new dispersive liquid-liquid microextraction, magnetic stirrer induced dispersive ionic-liquid microextraction (MS-IL-DLLME) was developed to quantify the trace level of vanadium in real water and food samples by graphite furnace atomic absorption spectrometry (GFAAS). In this extraction method magnetic stirrer was applied to obtained a dispersive medium of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] in aqueous solution of (real water samples and digested food samples) to increase phase transfer ratio, which significantly enhance the recovery of vanadium - 4-(2-pyridylazo) resorcinol (PAR) chelate. Variables having vital role on desired microextraction methods were optimised to obtain the maximum recovery of study analyte. Under the optimised experimental variables, enhancement factor (EF) and limit of detection (LOD) were achieved to be 125 and 18 ng L(-1), respectively. Validity and accuracy of the desired method was checked by analysis of certified reference materials (SLRS-4 Riverine water and NIST SRM 1515 Apple leaves). The relative standard deviation (RSD) for 10 replicate determinations at 0.5 μg L(-1) of vanadium level was found to be <5.0%. This method was successfully applied to real water and acid digested food samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Survey of nasal carriage of Staphylococcus aureus and intestinal parasites among food handlers working at Gondar University, Northwest Ethiopia.

    Science.gov (United States)

    Dagnew, Mulat; Tiruneh, Moges; Moges, Feleke; Tekeste, Zinaye

    2012-10-02

    Food borne disease are major health problems in developing countries like Ethiopia. Food handlers with poor personal hygiene working in food establishments could be potential sources of disease due to pathogenic organisms. However; information on disease prevalence among food handlers working in University of Gondar cafeterias are very scarce. The aim of this study is to assess the prevalence of nasal carriage of Staphylococcus aureus, their drug resistance pattern and prevalence of intestinal parasites among food handlers working in University of Gondar student's cafeterias. A cross sectional study was conducted among food handlers working in University of Gondar student's cafeterias. A pretested structured questionnaire was used for collecting data. Nasal swab and stool were investigated for S. aureus and intestinal parasites; respectively as per the standard of the laboratory methods. Among 200 food handlers, females comprised 171(85.5%). The majority (67.5%) of the food-handlers were young adults aged 18-39 years. One hundred ninety four (97%) of the food handlers were not certified as a food handler. Forty one (20.5%) food handlers were positive for nasal carriage of S. aureus, of these 4(9.8%) was resistant for methicilin. Giardia lamblia was the most prevalent parasites 22 (11%), followed by Ascaris lumbricoides 13(6.5%), Entamoeba histolytica 12 (6%), Strongyloides stercolaris (0.5), Taenia species 1(0.5%) and Schistosoma mansoni 1(0.5%). The finding stressed that food handlers with different pathogenic micro organisms may pose significant risk on the consumers. Higher officials should implement food handler's training on food safety, periodic medical checkup and continuous monitoring of personal hygiene of food handlers.

  8. Visual illusion in mass estimation of cut food.

    Science.gov (United States)

    Wada, Yuji; Tsuzuki, Daisuke; Kobayashi, Naoki; Hayakawa, Fumiyo; Kohyama, Kaoru

    2007-07-01

    We investigated the effect of the appearance of cut food on visual mass estimation. In this experiment, we manipulated the shape (e.g., a block, fine strips, or small cubes) of food samples of various masses, and presented them on a CRT display as stimuli. Eleven subjects participated in tasks to choose the picture of the food sample which they felt indicated a target mass. We used raw carrots and surimi (ground fish) gel as hard and soft samples, respectively. The results clearly confirm an existence of an illusion, and this indicates that the appearance of food interferes with visual mass estimation. Specifically, participants often overestimated the mass of finely cut food, especially fine strips, whereas they could accurately estimate the mass of block samples, regardless of the physical characteristics of the foods. The overestimation of the mass of cut food increased with the food's actual mass, and was particularly obvious with increases of apparent volume when cut into fine strips. These results suggest that the apparent volume of a food sample effects the visual estimation of its mass. Hence we can conclude that there are illusions associated with the visual presentation of food that may influence various food impressions, including satisfaction and eating behaviour.

  9. Evaluation of different methods to recover methicillin-resistant Staphylococcus aureus from hospital environmental surfaces.

    LENUS (Irish Health Repository)

    Dolan, A

    2011-11-01

    The environment is implicated as a source of healthcare-associated infections (HAIs) and there is a need for evidence-based approaches to environmental sampling to assess cleanliness and improve infection prevention and control. We assessed, in vitro, different approaches to sampling the environment for meticillin-resistant Staphylococcus aureus (MRSA). In a laboratory-based investigation, the recovery of MRSA from two common hospital environments using six different sampling methods was evaluated, with a wild-type strain of MRSA. A 100 cm(2) section of mattress and a laboratory bench surface were contaminated with known inocula of MRSA. Bacteria were recovered by sampling at 30 min after inoculation, using either saline-moistened cotton swabs, neutralising buffer swabs, eSwabs or macrofoam swabs, which were all enriched in tryptone soya broth, or by sampling with direct contact plates or chromogenic \\'sweep\\' plates. The sensitivity (i.e. the minimum number of bacteria inoculated on to a surface which subsequently produced a positive result) of each method was determined for each surface. The most sensitive methods were eSwabs and macrofoam swabs, requiring 6.1 × 10(-1) and 3.9 × 10(-1) MRSA\\/cm(2), respectively, to produce a positive result from the bench surface. The least sensitive swabbing method was saline-moistened cotton swabs, requiring 1.1 × 10(3) MRSA\\/cm(2) of mattress. The recovery of bacteria from environmental samples varies with the swabs and methodology used and negative culture results do not exclude a pathogen-free environment. Greater standardisation is required to facilitate the assessment of cleanliness of healthcare environments.

  10. Science.gov (United States)

    MOSUGU, J.I.; ADESOKAN, H.K.

    2016-01-01

    Summary Introduction. Food contamination with Listeria monocytogenes is on the increase posing threats to public health with growing trends in food products recalls due to suspected Listeria contamination. Methods. We conducted a cross-sectional study to determine the prevalence and antibiotic susceptibility profiles of Listeria monocytogenes (Lm) among 71 randomly selected poultry farms in Oyo State, Nigeria. A total of 450 samples comprising cloacal swabs (426) and randomly selected dressed chicken meat (24) were cultured for Lm isolation using BrillianceTM Selective Listeria Agar with antibiotics and microbial load count with Nutrient Agar. Further identification was done using microscopic, biochemical characterization and antibiotic sensitivity tests. Data were analysed using bivariate analysis and student t-test. Results. An overall prevalence of 91.8% Lm contamination was obtained comprising 91.5% (390/426) in cloacal swabs and 95.8% (23/24) in meat. The prevalence of Lm in cloacal samples was significantly associated with poultry type (p = 0.008) and breed (p = 0.000. In addition, all the flocks had at least one positive sample yielding 100% flock prevalence. Antibiotic sensitivity test revealed that most of the isolates were resistant to common antibiotics like Ampicillin-cloxacillin and cefuroxime. Conclusions. The results revealed a high level of contamination with Lm in the poultry flock and meat and the observed resistance to most common antibiotics has implications for future disease control as well as public health. There is need to step up routine screening of food animal products for Listeria contamination as well as measures towards reducing such contaminations. PMID:27980380

  11. Prevalence and antibiotic susceptibility profiles of Listeria monocytogenes contamination of chicken flocks and meat in Oyo State, south-western Nigeria: Public health implications.

    Science.gov (United States)

    Ishola, O O; Mosugu, J I; Adesokan, H K

    2016-09-01

    Food contamination with Listeria monocytogenes is on the increase posing threats to public health with growing trends in food products recalls due to suspected Listeria contamination. We conducted a cross-sectional study to determine the prevalence and antibiotic susceptibility profiles of Listeria monocytogenes (Lm) among 71 randomly selected poultry farms in Oyo State, Nigeria. A total of 450 samples comprising cloacal swabs (426) and randomly selected dressed chicken meat (24) were cultured for Lm isolation using BrillianceTM Selective Listeria Agar with antibiotics and microbial load count with Nutrient Agar. Further identification was done using microscopic, biochemical characterization and antibiotic sensitivity tests. Data were analysed using bivariate analysis and student t-test. An overall prevalence of 91.8% Lm contamination was obtained comprising 91.5% (390/426) in cloacal swabs and 95.8% (23/24) in meat. The prevalence of Lm in cloacal samples was significantly associated with poultry type (p = 0.008) and breed (p = 0.000. In addition, all the flocks had at least one positive sample yielding 100% flock prevalence. Antibiotic sensitivity test revealed that most of the isolates were resistant to common antibiotics like Ampicillin-cloxacillin and cefuroxime. The results revealed a high level of contamination with Lm in the poultry flock and meat and the observed resistance to most common antibiotics has implications for future disease control as well as public health. There is need to step up routine screening of food animal products for Listeria contamination as well as measures towards reducing such contaminations.

  12. Association between traditional food consumption and motives for food choice in six European countries.

    Science.gov (United States)

    Pieniak, Zuzanna; Verbeke, Wim; Vanhonacker, Filiep; Guerrero, Luis; Hersleth, Margrethe

    2009-08-01

    This study investigates the association between traditional food consumption and motives for food choice in six European countries. Cross-sectional data were collected through the TRUEFOOD pan-European consumer survey (n = 4828) with samples representative for age, gender and region in Belgium, France, Italy, Norway, Poland and Spain. Importance attached to familiarity with a product is found to be strongly and positively associated with general attitude toward traditional food as well as traditional food consumption. The importance attached to convenience was negatively related to both general attitude toward traditional food and traditional food consumption, while the importance of weight control negatively influenced the general attitude. Natural content of food was positively associated with the attitude toward traditional food and traditional food consumption. The importance of price when purchasing food failed to be significantly related with general attitude and traditional food consumption both for the pooled sample as well as within each country except in Spain. The proposed model contributes to a better understanding of factors shaping the image and influencing the consumption of traditional foods in Europe. General attitude toward traditional foods, familiarity, and importance of food naturalness emerged as drivers for traditional food consumption. Importance attached to convenience and health acted as direct barriers to traditional food consumption, whereas importance of weight control emerged as an indirect barrier through lowering general attitude toward traditional foods.

  13. Household income differences in food sources and food items purchased.

    Science.gov (United States)

    French, Simone A; Wall, Melanie; Mitchell, Nathan R

    2010-10-26

    The present study examined income-related household food purchases among a sample of 90 households from the community. Annotated food purchase receipts were collected for a four-week period by the primary household shopper. Receipt food source and foods items were classified into specific categories, and food quantities in ounces were recorded by research staff. For home sources, a limited number of food/beverage categories were recorded. For eating out sources, all food/beverage items were recorded. Median monthly per person dollars spent and per person ounces purchased were computed. Food sources and food categories were examined by household income tertile. A community-based sample of 90 households. Higher income households spent significantly more dollars per person per month from both home and eating out sources compared with lower income households ($163 versus $100, p income households, higher income households spent significantly more home source dollars on both fruits/vegetables (21.5 versus 10.2, p income households (45% versus 26%, p sources, lower income households spent a significantly greater percent of dollars per person at carry out places (54% versus 37%, p income differences were observed for dollars spent at discount grocery stores, small grocery stores or convenience stores. Higher income households spent more money on both healthy and less healthy foods from a wide range of sources. Lower income households spent a larger proportion of their eating out dollars at carry out places, and a larger proportion of their home beverage purchases were sugar sweetened beverages.

  14. Sample preparation for arsenic speciation analysis in baby food by generation of substituted arsines with atomic absorption spectrometry detection.

    Science.gov (United States)

    Huber, Charles S; Vale, Maria Goreti R; Dessuy, Morgana B; Svoboda, Milan; Musil, Stanislav; Dědina, Jiři

    2017-12-01

    A slurry sampling procedure for arsenic speciation analysis in baby food by arsane generation, cryogenic trapping and detection with atomic absorption spectrometry is presented. Several procedures were tested for slurry preparation, including different reagents (HNO 3 , HCl and tetramethylammonium hydroxide - TMAH) and their concentrations, water bath heating and ultrasound-assisted agitation. The best results for inorganic arsenic (iAs) and dimethylarsinate (DMA) were reached when using 3molL -1 HCl under heating and ultrasound-assisted agitation. The developed method was applied for the analysis of five porridge powder and six baby meal samples. The trueness of the method was checked with a certified reference material (CRM) of total arsenic (tAs), iAs and DMA in rice (ERM-BC211). Arsenic recoveries (mass balance) for all samples and CRM were performed by the determination of the tAs by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted digestion and its comparison against the sum of the results from the speciation analysis. The relative limits of detection were 0.44, 0.24 and 0.16µgkg -1 for iAs, methylarsonate and DMA, respectively. The concentrations of the most toxic arsenic species (iAs) in the analyzed baby food samples ranged between 4.2 and 99µgkg -1 which were below the limits of 300, 200 and 100µgkg -1 set by the Brazilian, Chinese and European legislation, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Detection of ionized foods

    International Nuclear Information System (INIS)

    Beerens, H.

    1986-01-01

    Irradiated foods and feed might be identified with two kinds of tests: 1. biochemical: detection of specific products are not yet available 2. microbiological: when a microbial species dissapears from a sample of food i.e. it is not detectable after enrichment (for instance Coliforms in hamburgers) it is likely that the sample has been ionized [fr

  16. Control of food irradiation in Denmark

    International Nuclear Information System (INIS)

    Leth, T.

    1996-01-01

    In Denmark food irradiation is not allowed. However, with the consideration within EEC about directives regulating food irradiation and the development of methods for detection, it has been found necessary to ascertain that illegally irradiated foods are not found on the Danish market. Irradiation of spices is allowed in many countries even without being declared in the foods. It thus seemed logical to begin the control of food irradiation by screening a number of spices. This resulted in 1992 in the assessment of 105 samples and in 1993 of 48 samples. (author)

  17. 21 CFR 1005.10 - Notice of sampling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Notice of sampling. 1005.10 Section 1005.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH IMPORTATION OF ELECTRONIC PRODUCTS Inspection and Testing § 1005.10 Notice of sampling...

  18. Total arsenic in selected food samples from Argentina: Estimation of their contribution to inorganic arsenic dietary intake.

    Science.gov (United States)

    Sigrist, Mirna; Hilbe, Nandi; Brusa, Lucila; Campagnoli, Darío; Beldoménico, Horacio

    2016-11-01

    An optimized flow injection hydride generation atomic absorption spectroscopy (FI-HGAAS) method was used to determine total arsenic in selected food samples (beef, chicken, fish, milk, cheese, egg, rice, rice-based products, wheat flour, corn flour, oats, breakfast cereals, legumes and potatoes) and to estimate their contributions to inorganic arsenic dietary intake. The limit of detection (LOD) and limit of quantification (LOQ) values obtained were 6μgkg(-)(1) and 18μgkg(-)(1), respectively. The mean recovery range obtained for all food at a fortification level of 200μgkg(-)(1) was 85-110%. Accuracy was evaluated using dogfish liver certified reference material (DOLT-3 NRC) for trace metals. The highest total arsenic concentrations (in μgkg(-)(1)) were found in fish (152-439), rice (87-316) and rice-based products (52-201). The contribution to inorganic arsenic (i-As) intake was calculated from the mean i-As content of each food (calculated by applying conversion factors to total arsenic data) and the mean consumption per day. The primary contributors to inorganic arsenic intake were wheat flour, including its proportion in wheat flour-based products (breads, pasta and cookies), followed by rice; both foods account for close to 53% and 17% of the intake, respectively. The i-As dietary intake, estimated as 10.7μgday(-)(1), was significantly lower than that from drinking water in vast regions of Argentina. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Autoinducer-2-like activity associated with foods and its interaction with food additives.

    Science.gov (United States)

    Lu, Lingeng; Hume, Michael E; Pillai, Suresh D

    2004-07-01

    The autoinducer-2 (AI-2) molecule produced by bacteria as part of quorum sensing is considered to be a universal inducer signal in bacteria because it reportedly influences gene expression in a variety of both gram-negative and gram-positive bacteria. The objective of this study was to determine whether selected fresh produce and processed foods have AI-2-like activity and whether specific food additives can act as AI-2 mimics and result in AI-2-like activity. The luminescence-based response of the reporter strain Vibrio harveyi BB170 was used as the basis for determining AI-2 activity in the selected foods and food ingredients. Maximum AI-2 activity was seen on the frozen fish sample (203-fold, compared with the negative control) followed by tomato, cantaloupe, carrots, tofu, and milk samples. Interestingly, some samples were capable of inhibiting AI-2 activity. Turkey patties showed the highest inhibition (99.8% compared with the positive control) followed by chicken breast (97.5%), homemade cheeses (93.7%), beef steak (90.6%), and beef patties (84.4%). AI-2 activity was almost totally inhibited by sodium propionate, whereas sodium benzoate caused 93.3% inhibition, compared with 75% inhibition by sodium acetate. Sodium nitrate did not have any appreciable effect, even at 200 ppm. Understanding the relationships that exist between AI-2 activity on foods and the ecology of pathogens and food spoilage bacteria on foods could yield clues about factors controlling food spoilage and pathogen virulence.

  20. Food Insecurity, Poor Diet Quality, and Obesity among Food Pantry Participants in Hartford, CT

    Science.gov (United States)

    Robaina, Kate A.; Martin, Katie S.

    2013-01-01

    Objective: Examine relationships between food security, diet quality, and body mass index (BMI) among food pantry users. Methods: Convenience sample of 212 food pantry clients in Hartford, CT from June, 2010 to May, 2011. Main outcomes included food security (United States Department of Agriculture module), fruit and vegetable consumption (Block…