WorldWideScience

Sample records for sutured posterior chamber

  1. Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

    Science.gov (United States)

    Parekh, Parag; Green, W Richard; Stark, Walter J; Akpek, Esen Karamursel

    2007-02-01

    To report the occurrence of subluxation of suture-fixated posterior chamber (PC) intraocular lenses (IOL) and elucidate the mechanisms involved. Prospective clinicopathologic study. A single 10-0 Prolene suture explanted from a patient who experienced subluxation of his PC-IOL, 11.5 years after placement. Furthermore, multiple 10-0 Prolene sutures and PC-IOLs used for iris fixation were studied as controls. Scanning electron microscopy (SEM) was used to analyze the surface of the explanted suture. In addition, randomly selected 10-0 Prolene sutures cut with Vannas scissors and cut with the positioning holes of a randomly selected PC-IOL identical to that implanted in the patient's eye were examined as controls. Finally, the positioning holes of several randomly selected, iris-fixated PC-IOLs were studied using SEM with particular attention to surface quality and edge finish. Presence of any signs of suture degradation, the character of the cut edge of the suture, as well as the characteristics of the positioning holes of the PC-IOLs. Scanning electron microscopy of the explanted suture revealed sharply cut edges, without significant degradation of the suture, and no intact loop. Scanning electron microscopy of the control suture cut with a PC-IOL demonstrated a similarly cut edge. The positioning holes of the examined PC-IOLs had a sharp edge, and some also had an imperfect finish. We conclude that the surface properties of the positioning holes lead to cutting of the suture, and subsequent subluxation of the PC-IOL.

  2. Implantation of scleral fixated sutured posterior chamber lenses: a retrospective analysis of 119 cases.

    Science.gov (United States)

    Krause, Lothar; Bechrakis, Nikolaos E; Heimann, Heinrich; Salditt, Stefan; Foerster, Michael H

    2009-08-01

    The implantation of scleral fixated sutured posterior chamber lenses enables lens implantation in the absence of adequate lens capsule support. Anterior chamber lenses and their side effects can also be avoided, particularly in cases of unilateral aphakia and contact lens incompatibility. This study is a retrospective analysis of 119 scleral fixated sutured posterior chamber lenses implanted in 115 patients. Seventy-nine cases of damaged zonula or damaged lens capsule and 17 cases of corneal decompensation secondary to anterior chamber lenses were the main indications for the suture fixation. The mean follow-up was 23 months (6-83 months). In 50% of all cases, improved visual acuity was achieved. Twenty-four percent of patients showed unchanged visual acuity, while 26% had poorer vision postoperatively, mainly because of corneal decompensation following anterior chamber lens explantation. The main postoperative complication was transient rise of intraocular pressure, occurring in 44% of the cases. In most cases improved or comparable postoperative visual acuity was achieved. The main complication observed was postoperative glaucoma, especially in patients with pre-existing glaucoma.

  3. Results and complications of scleral fixated (Sutured posterior chamber intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Amoozadeh J

    2001-08-01

    Full Text Available Optical rehabilitation of the patient with aphakia who cannot tolerate contact lenses present a therapeutic challenge. In the absence of capsular support, anterior chamber lenses have been widely used. On the other hand intraocular lens implantation of scleral sutured posterior chamber intraocular lens during penterating keratoplasty or insufficient iris support is recommended. The purpose of this study is to evaluate the clinical outcome and complication in 17 patients who underwent scleral-fixation of an intraocular lens.We studied prospectively the results of posterior chamber intraocular lens implantation by scleral fixation in 17 eyes of 17 patients without a complete posterior lens capsule support at farabi Eye Hospital. Uncorrected visual acuity improved from counting finger to 20/40 or better in 9 eyes (53 percent. The following complications were observed during the mean postoperative follow-up of 7.2 (range 3-12 months; increased intraocular pressure in 5 eyes, vitreous hemorrhage and icr hyphema in 2 eyes, cystoid macular edema (CME and vitritis in one eye, and endophthalmitis and retinal detachment in one eye. Posterior chamber intraocular lens implantation by scleral fixation is a relatively safe procedure and can be recommended for many patients

  4. PARS PLANA VITRECTOMY WITH ANTERIOR CHAMBER VERSUS GORE-TEX SUTURED POSTERIOR CHAMBER INTRAOCULAR LENS PLACEMENT: LONG-TERM OUTCOMES.

    Science.gov (United States)

    Khan, M Ali; Gupta, Omesh P; Pendi, Kasim; Chiang, Allen; Vander, James; Regillo, Carl D; Hsu, Jason

    2018-01-16

    To compare clinical outcomes of combined pars plana vitrectomy (PPV) with anterior chamber intraocular lens (ACIOL) placement versus scleral fixation of a posterior chamber intraocular lens (PCIOL) using Gore-Tex suture. Retrospective, interventional case series of eyes undergoing combined PPV and IOL placement for retained lens material, aphakia, or dislocated IOL. Eyes with history of amblyopia, corneal opacity, retinal, or optic nerve disease were excluded. Outcome measures were change in visual acuity and occurrence of postoperative complications with minimum follow-up of 1 year. Sixty-three eyes of 60 patients were identified. Thirty-three eyes underwent combined PPV and ACIOL placement and 30 eyes underwent combined PPV and scleral fixation of a PCIOL using Gore-Tex suture. Mean follow-up was 502 ± 165 days (median 450, range 365-1,095 days). In the ACIOL group, mean visual acuity improved from 20/914 preoperatively to 20/50 postoperatively (P Gore-Tex suture were well tolerated. The techniques resulted in similar visual outcomes at minimum follow-up of 1 year.

  5. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  6. Operating microscope light-induced phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens implantation.

    Science.gov (United States)

    Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun

    2009-01-01

    The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.

  7. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  8. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman’s Knot

    Directory of Open Access Journals (Sweden)

    Yong Un Shin

    2017-01-01

    Full Text Available Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL using a single fisherman’s knot (SFK. Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  9. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot.

    Science.gov (United States)

    Shin, Yong Un; Seong, Mincheol; Cho, Hee Yoon; Kang, Min Ho

    2017-01-01

    To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  10. [Endoscopically controlled optimization of trans-scleral suture fixation of posterior chamber lenses in the ciliary sulcus].

    Science.gov (United States)

    Althaus, C; Sundmacher, R

    1993-08-01

    Two technical difficulties have to be overcome in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration through the sulcus, and second, exact positioning of the PCL haptics in the sulcus. Incongruence of the two may lead to long-term complications by compression or even strangulation of ciliary processes. Intraocular endoscopy was used intraoperatively to visualize the site of needle penetration and the final location of the haptics in patients. It turned out that with our previously described standard techniques the precision was far less than anticipated. Thus, new technical ways had to be sought to improve the precision of positioning. In secondary implantation without perforating keratoplasty we achieved the best results when the needle was passed ab externo before opening the eye and before anterior vitrectomy, taking advantage of a precisely prepared sclerocorneal zone. Passing the needle ab externo in an already hypotonic eyeball gives much less precise results. In combination with perforating keratoplasty with an open-sky approach, needle penetration ab interno is reliable. Correct positioning of the PCL haptics is at least as difficult as correct needle penetration, a fact which up to now has mostly been ignored. In 33 consecutively operated eyes the technique of implantation and PCL design was varied under endoscopical control.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries

    Directory of Open Access Journals (Sweden)

    Xiangjia Zhu

    2017-01-01

    Full Text Available Purpose. To evaluate the tilt, decentration, and internal higher-order aberrations (HOAs of sutured posterior-chamber intraocular lenses (IOLs in patients with open globe injuries. Methods. 46 consecutive patients (47 eyes who underwent transsclerally sutured IOL implantation were enrolled in this prospective cohort study. Nineteen eyes had a history of open globe injury. The tilt and decentration of the IOLs and the visual quality were measured 1 month after surgery. Results. The horizontal tilt and decentration of the IOLs in the open-globe-injury group were significantly higher than those in the control group (both P<0.05. In the open-globe-injury group, the horizontal decentration was significantly greater in the limbus-sclera-involved group (n=11 than in the only-cornea-involved group (n=8, P=0.040. The internal coma, 3rd-order, and total HOA values at pupil sizes of 4 mm (P=0.006 and 6 mm (P=0.013 were significantly higher in the open-globe-injury group than in the controls. Consequently, the optical quality data for the modulation transfer function and the Strehl ratio (all P<0.05 were significantly poorer in the open-globe-injury group. Conclusions. Open globe injuries damage the structural integrity of the eyeball, resulting in more-misaligned sutured IOLs and poorer visual quality.

  12. Posterior Chamber Scleral Fixation of Intraocular Lenses in Post-Vitrectomised Aphakic Eyes.

    Science.gov (United States)

    Obeng, Francis Kwasi; Vig, Vipan Kumar; Singh, Preetam; Singh, Rajbir; Dhawan, Bodhraj; Sahajpal, Nikhil

    2017-03-01

    The best method of aphakia correction is in the bag implantation of Posterior Chamber Intraocular Lens (PCIOL). When this ideal procedure is not possible due to lack of integrity of posterior capsule or zonules, the other alternatives are broadly categorized into two: extraocular and intraocular. Whereas, the former includes contact lenses and aphakic glasses, the latter ones are further divided into anterior and posterior chamber methods. Anterior Chamber Intraocular Lenses (ACIOL) can be with or without iris claw. At the posterior chamber, fixation of the lenses can be with glue or sutures. When there is combined Pars Plana Vitrectomy (PPV) and lensectomy or if the indication of PPV is dropped nucleus or intraocular lens, a modality of aphakia correction should be devised. Posterior Chamber Scleral Fixation of Intraocular Lenses (PCSFIOL) with sutures is a preferred method because of its low complication profile. However, data on correction of aphakia after combined PPV and lensectomy is limited. To fill in this gap in knowledge, we evaluated the secondary PCSFIOL in aphakic eyes after previous PPV and lensectomy. To assess the outcome and complication profile of a large series of patients who underwent secondary PCSFIOL implantation with sutures after combined PPV and lensectomy. Records of all patients who had undergone secondary PCSFIOL implantation with sutures after combined PPV and lensectomy from 2010 to 2014 were reviewed retrospectively for visual outcomes and complications. Patients' demographic data, indication for PPV, best corrected preoperative and postoperative visual acuities, complications of surgery, and indications of PCSFIOL and length of follow up were collected and analyzed. A total of 148 eyes of 148 patients (127 males and 21 females) were identified. Mean age at surgery was 32.5±8 years (range 2.5-73 years) with a mean follow up 23±14 months (range 3-114 months). A total of 95.27%, 2.70% and 2.02% of patients had improvement

  13. Posterior Chamber Scleral Fixation of Intraocular Lenses in Post-Vitrectomised Aphakic Eyes

    Science.gov (United States)

    Vig, Vipan Kumar; Singh, Preetam; Singh, Rajbir; Dhawan, Bodhraj; Sahajpal, Nikhil

    2017-01-01

    Introduction The best method of aphakia correction is in the bag implantation of Posterior Chamber Intraocular Lens (PCIOL). When this ideal procedure is not possible due to lack of integrity of posterior capsule or zonules, the other alternatives are broadly categorized into two: extraocular and intraocular. Whereas, the former includes contact lenses and aphakic glasses, the latter ones are further divided into anterior and posterior chamber methods. Anterior Chamber Intraocular Lenses (ACIOL) can be with or without iris claw. At the posterior chamber, fixation of the lenses can be with glue or sutures. When there is combined Pars Plana Vitrectomy (PPV) and lensectomy or if the indication of PPV is dropped nucleus or intraocular lens, a modality of aphakia correction should be devised. Posterior Chamber Scleral Fixation of Intraocular Lenses (PCSFIOL) with sutures is a preferred method because of its low complication profile. However, data on correction of aphakia after combined PPV and lensectomy is limited. To fill in this gap in knowledge, we evaluated the secondary PCSFIOL in aphakic eyes after previous PPV and lensectomy. Aim To assess the outcome and complication profile of a large series of patients who underwent secondary PCSFIOL implantation with sutures after combined PPV and lensectomy. Materials and Methods Records of all patients who had undergone secondary PCSFIOL implantation with sutures after combined PPV and lensectomy from 2010 to 2014 were reviewed retrospectively for visual outcomes and complications. Patients’ demographic data, indication for PPV, best corrected preoperative and postoperative visual acuities, complications of surgery, and indications of PCSFIOL and length of follow up were collected and analyzed. Results A total of 148 eyes of 148 patients (127 males and 21 females) were identified. Mean age at surgery was 32.5±8 years (range 2.5-73 years) with a mean follow up 23±14 months (range 3-114 months). A total of 95.27%, 2

  14. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Scharioth, Gabor B; Prasad, Som; Georgalas, Ilias; Tataru, Calin; Pavlidis, Mitrofanis

    2010-02-01

    To report the intermediate multicenter results of a technique of sutureless intrascleral fixation of a standard 3-piece posterior chamber intraocular lens (PC IOL) in the ciliary sulcus. Four European ophthalmology centers. A technique for sutureless intrascleral fixation of the haptics of a standard 3-piece PC IOL was retrospectively evaluated. The technique uses standardized maneuvers to fixate the PC IOL without need for special haptic architecture or preparation or haptic suturing. All patients having IOL implantation by the technique were evaluated for preoperative status (visual acuity, refractive error, preexisting ocular conditions, optical biometry), postoperative status, complications, and need for further surgery. The study evaluated 63 consecutive patients from 4 institutions (4 surgeons). The median follow-up was 7 months. Two dislocated PC IOLs (3.6%) were decentered; the other 61 IOLs (96.8%) were stable and well centered. There were no cases of recurrent dislocation, endophthalmitis, retinal detachment, or glaucoma. Fixation of PC IOL haptics in a limbus-parallel scleral tunnel provided exact centration and axial stability of the IOL and prevented distortion and subluxation in most cases. Copyright 2010 ASCRS and ESCRS. All rights reserved.

  15. Initial Experience With Posterior Chamber Intraocular Lens Implant ...

    African Journals Online (AJOL)

    The results of extracapsular cataract extraction with posterior chamber intraocular lens implant at the Jos University Teaching Hospital are reviewed. The results suggest that despite lack of facilities to calculate the lens power for emmetropia, the use of a standard lens of about 19.0D will provide a good number of our ...

  16. Posterior chamber volume does not change significantly during dilation.

    Science.gov (United States)

    Dorairaj, S; Liebmann, J M; Tello, C; Barocas, V H; Ritch, R

    2009-11-01

    To determine whether the volume of the posterior chamber changes during pupillary dilation. Eyes with anatomically narrow angles underwent ultrasound biomicroscopy of the posterior chamber and pupillary margin under dark- and light-room conditions to assess changes in posterior chamber anatomy and volume. All examinations were stored as real-time video. A frame-by-frame analysis was performed using a macro written for the ImageJ image-processing software. Thirteen eyes were assessed. The mean patient age was 63.0 (SD 10.0) years, and the mean refractive error was 1.1 (1.9) dioptres. The horizontal mean pupillary diameter was 2.3 (0.6) mm and 3.5 (0.5) mm under light- and dark-room conditions, respectively (pchamber volumes were unchanged under light and dark conditions (3.76 (1.09) vs 3.63 (0.78) mm(3), p = 0.22, paired t test). Volumes were greater under light conditions in eight eyes and under dark conditions in five eyes. The volume of the posterior chamber does not change significantly during dilation.

  17. Deficient language acquisition in children with single suture craniosynostosis and deformational posterior plagiocephaly.

    Science.gov (United States)

    Korpilahti, Pirjo; Saarinen, Pia; Hukki, Jyri

    2012-03-01

    This study examined early language acquisition in children with single suture craniosynostosis (SSC) and in children with deformational posterior plagiocephaly. Our purpose was to determine whether infants with SSC have normal language acquisition at the age of 3 years, and whether infants with deformational posterior plagiocephaly demonstrate parallel development when compared with children with SSC. The study population includes 61 infants. Twenty of them had synostosis of the sagittal suture, 12 synostosis of other suture and 29 deformational posterior plagiocephaly. Forty-nine of them were operated on a mean age of 10.6 months, and 12 were non-operated children with deformational posterior plagiocephaly. Language skills of participants were prospectively evaluated at the mean age of 3 years 4 months. About one half of the subjects (49%) had normal linguistic development, 30% had slight developmental problems and 21% had severe disorders in speech-language-related skills. These figures showed the prevalence of severe language disorders to be three times higher in our study population when compared with the general population. Children with sagittal synostosis managed better in all language skills compared with other types of SSC. Defective language development was found in deformational posterior plagiocephaly, both operated and non-operated. We found a noticeable developmental risk for specific language impairment in children with nonsyndromic SSC, and that the deviant language development is observable already in early infancy. Contrary to previous beliefs, the developmental risk for defective language development in deformational posterior plagiocephaly was found in both operated and non-operated subjects.

  18. Evaluation of pars plana sclera fixation of posterior chamber intraocular lens

    Directory of Open Access Journals (Sweden)

    Fangju Han

    2014-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL implantation with transscleral fixation. Design and Setting: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People′s Hospital. Materials and Methods: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. Results: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05. No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. Conclusion: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support.

  19. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  20. The 'WiFi' otoplasty : Combined concentric posterior microchondrectomies and sutures for correction of prominent ears.

    Science.gov (United States)

    Hendrickx, Benoit I M M; Hamdi, Moustapha; Zeltzer, Assaf; Greensmith, Andrew

    2018-02-19

    Prominent ears are by far the most common congenital ear deformity. Many techniques have been described using one or a combination of 3 basic methods: cartilage cutting, cartilage weakening and pure cartilage shaping techniques. The ideal otoplasty technique should yield a natural correction of the deformity, with low recurrence rates and with little risk of complications. A new cartilage shaping technique using closing wedge concentric microchondrectomies through an entirely posterior approach is presented. Between 2006 and 2017, 200 bilateral otoplasties using this 'WiFi' pattern technique were performed. This technique combined with Mustarde sutures is based on the excision of concentric partial thickness cartilage wedges designed in the pattern of the WiFi symbol. There were no major complications such as anterior skin necrosis and no returns to theatre for infections or haematomas. 3 patients (1.5%) had complete recurrence of the deformity and 10 patients (5%) had to undergo a minor revision for recurrence at the upper pole. 5 patients have had exposure of the end of the permanent upper pole scapho-temporal suture more than 3 months after surgery requiring simple outpatient suture trimming/removal without any recurrence of results. Palpable or bridging sutures were present upon clinical examination in 10 patients (5%) but did not require revision surgery. Here, we describe a fast, safe and reliable technique for otoplasty with no need for extensive dissection, which is applicable to the full range of deformity. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  1. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  2. Glued intrascleral fixation of posterior chamber intraocular lens in children.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Prakash, Dimple; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya

    2012-04-01

    To evaluate the short-term results of glued intrascleral fixation of posterior chamber intraocular lens (glued IOL) in children without adequate capsular support. Noncomparative retrospective observational case series. Institutional practice. Forty-one eyes of 33 children who underwent glued IOL implantation were retrospectively evaluated. The indications were postsurgical aphakia, subluxated cataract, ectopia lentis, traumatic subluxation, and decentered IOL. Visual acuity (VA), endothelial cell changes, intraoperative and postoperative complications. The mean age at the time of glued IOL was 10.7±3.6 years (range 5-15). The mean duration of follow-up after surgery was 17.5±8.5 months (range 12-36). The mean postoperative best spectacle-corrected visual acuity (BCVA in decimal equivalent) was 0.43±0.33 and there was significant change noted (P20/60 BCVA was obtained in 17.1% and 46.3% of eyes respectively. BCVA improvement more than 1 line was seen in 22 eyes (53.6%). The mean postoperative refraction was myopic (-1.19±0.7 diopters [D]) in 19 eyes and hyperopic (+1.02±0.7 D) in 22 eyes. The mean endothelial loss was 4.13% (range 1.3%-5.94%). The 3 causes of reduced BCVA were the preexisting corneal, retinal pathology, and amblyopia. Postoperative complications included optic capture in 1 eye (2.4%), macular edema in 2 eyes (4.8%), and clinical decentration in 2 eyes (4.8%). There was no postoperative retinal detachment, IOL dislocation, endophthalmitis, or glaucoma. Short-term results in children after glued IOL were favorable, with a low rate of complications. However, regular follow-ups are required since long-term risks are unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Coaptive film versus subcuticular suture: comparing skin closure time after posterior spinal instrumented fusion in pediatric patients with spinal deformity.

    Science.gov (United States)

    Grottkau, Brian E; Rebello, Gleeson; Merlin, Gabriel; Winograd, Jonathan M

    2010-11-01

    A prospective, randomized trial comparing skin closure time between coaptive film and subcuticular Monocryl sutures in children undergoing posterior instrumented spinal fusion. To prospectively compare skin closure time, complication rate and cosmetic result between coaptive film and subcuticular Monocryl wound closures in pediatric spine surgery. Posterior instrumented spinal fusions for spinal deformity in children are time-consuming ventures that are demanding on both the patient and physician. Minimizing the time for skin closure at the end of prolonged surgery diminishes the physical burden on the surgeon, the operating room personnel, and reduces operating room costs. Twenty-five children (mean age, 14.1 year) underwent posterior instrumented spinal fusion. Twenty-five incisions in 25 patients (12 closed with 3-0 subcuticular Monocryl sutures, 13 closed with coaptive film [Steri Strip S; 3 M company]) were evaluated. The method of skin closure was randomized before beginning the procedure and the surgeon informed just before skin closure. Closure time was recorded. A blinded plastic surgeon using a visual analogue scale assessed the cosmetic results at a minimum 3-month follow-up. Incisions closed with coaptive film required less time to complete than incisions closed with subcuticular suture. The mean time for skin closure using coaptive film was 290.62 seconds compared to the mean time of 674.75 seconds using Monocryl sutures (P < 0.000001). The average length of incisions closed with coaptive film was similar to the corresponding incisions that were closed with subcuticular Monocryl sutures (30.8 and 34.0 cm, respectively, P = 0.22). There was no significant difference in the cosmetic results or the number of wound complications using either technique. Coaptive film is a time-saving option for skin closure following pediatric spine surgery with comparable cosmetic results and no difference in complication rates.

  4. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  5. Suture associated corneal abscess three years after cataract surgery ...

    African Journals Online (AJOL)

    We describe a case of corneal abscess presenting three years after uneventful cataract extraction with posterior chamber lens implantation through a limbal incision secured with threesutures placed in the clear cornea. After removing the abscess, a loose10/0 nylon suture was found at the base of an ulcer. The suture was ...

  6. Correction effect of phakic posterior chamber implantable contact lens implantation on high myopia

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2018-02-01

    Full Text Available AIM: To analyze the clinical efficacy of phakic posterior chamber implantable contact lens(ICLimplantation on high myopia patients. METHODS: Thirty-four patients(68 eyeswho checked and diagnosed as high myopia in our hospital from June 2014 to June 2015 were selected as the clinical research subjects, and all the patients were given phakic posterior chamber intraocular lens implantation treatment. The diopter, visual acuity recovery, central anterior chamber depth, corneal endothelial cell count, and intraocular pressure after treatment were observed. RESULTS: The equivalent spherical refraction, central anterior chamber depth, uncorrected visual acuity and best corrected visual acuity recovery at 1, 3 and 6mo, 1 and 2a after treatment were better than those before treatment, and the differences were statistically significant(PP>0.05. There were no significant differences in uncorrected visual acuity, best corrected visual acuity, equivalent spherical refraction and central anterior chamber depth at 1, 3mo and 1 and 2a after treatment(P>0.05. CONCLUSION: The application of phakic posterior chamber intraocular lens implantation for the treatment of high myopia patients can improve the equivalent spherical refraction and central anterior chamber depth, improve uncorrected visual acuity, meanwhile, it has less effect on the patient's intraocular pressure and corneal endometrial cells, the effect maintenance and safety is better which meet their expectations.

  7. Changes of anterior and posterior corneal curvature and anterior chamber depth after SMILE

    Directory of Open Access Journals (Sweden)

    Li Li

    2017-12-01

    Full Text Available AIM: To observe the changes of anterior and posterior corneal curvature and anterior chamber depth after small incision lenticule extraction(SMILEfor low and high myopic astigmatism. METHODS: Sixty-three cases(88 eyesundergone SMILE in our hospital were included. The patients were divided into two groups based on astigmatism degree: the Group A: -2.00D to -4.00D astigmatism, the Group B: -0.25D to -1.00D astigmatism. Patients were examined at 1wk, 1 and 3mo after operations. Visual acuity, intraocular pressure, refraction, corneal curvature and anterior chamber depth were recorded. The change of anterior and posterior corneal curvature and anterior chamber depth was compared. Spearman correlation analysis and independent t test were used for statistical analysis. RESULTS: Surgery was done well in all patients without complications. No statistically significant difference was found between the two groups in posterior corneal curvature and anterior chamber depth preoperatively, postoperatively 7d,1 and 3mo(P>0.05. One week postoperatively, the anterior corneal curvature was statistically significant from that of preoperative in both groups(PP>0.05. CONCLUSION: No significant change of anterior and posterior corneal curvature and anterior chamber depth was found after SMILE for correcting low and high myopic astigmatism. One week after SMILE the anterior corneal curvature become stable.

  8. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Repair of Unstable Posterior Sternoclavicular Dislocation Using Nonabsorbable Tape Suture and Tension Band Technique: A Case Report with Good Results

    Directory of Open Access Journals (Sweden)

    Ekrem Aydın

    2015-01-01

    Full Text Available Posterior sternoclavicular joint dislocation (PSCJD is quite a rare condition. Nearly half of the closed reduction attempts fail due to various reasons. In this paper, we present a 25-year-old male patient who was admitted to the emergency department in our hospital after having a motor-vehicle accident. It was decided to do PSCJD after physical and imaging studies. Following necessary preparations, closed reduction was attempted with abduction-traction maneuver under general anesthesia; however, adequate stabilization could not be achieved and redislocation was detected during control. Therefore, joint was stabilized with tension band technique using 6 mm polyamide nonabsorbable type suture during open reduction. Painless and complete range of motion in shoulder was achieved at the postoperative 10th week.

  10. The phakic intraocular lens implant: in-depth focus on posterior chamber phakic IOLs.

    Science.gov (United States)

    Zaldivar, R; Ricur, G; Oscherow, S

    2000-02-01

    Phakic Intraocular surgery has come a long way in the past 20 years, especially in the evolution of posterior chamber phakic intraocular lenses (PC PIOLs). Clinical trials worldwide are showing acceptable results concerning efficacy, predictability, stability, and safety. PC PIOLS are proving to be a promising option for patients with high and extreme ametropia who cannot benefit from conventional corneal refractive procedures. This article provides an in-depth examination of PC PIOLs, their origin and evolution, and the results of past and current clinical studies. Reports of historical importance and studies published since the 1990s in peer-reviewed journals, textbooks, and monthly eye magazines, as well as Food and Drug Administration preliminary clinical findings, are reviewed. Anterior chamber phakic intraocular lenses are mentioned briefly.

  11. [Subluxation of scleral-fixated PC IOL caused by polypropylene suture degradation--case report].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Czarnowska, Elzbieta; Zajaczkowska, Agnieszka

    2009-01-01

    The purpose of the study is to evaluate factors related to late-onset of lens subluxation in transscleral sutured posterior chamber IOL. We report a child, which required surgical treatment for dislocation of a scleral-sutured PC IOL. 11 years earlier the secondary lens implantation with scleral fixation was performed in 4 years old boy. The first surgical procedure included an anterior victrectomy and suturing a single- piece PMMA IOL under the scleral flaps with a 10-0 polipropylene suture. The second--included explantation of the dislocated lens. Optic and scanning electron microscopy was used to analyze the surface of the explanted remnants of the breakage suture. Microscopic findings indicate that the late suture breakage and subluxation of suture-fixated PC IOL was due to the degradation of polypropylene suture.

  12. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  13. Suture supported P C IOL in a homocystinuric child.

    Directory of Open Access Journals (Sweden)

    Bhatti S

    1996-01-01

    Full Text Available A homocystinuric child presented with a secondary pupillary block glaucoma due to anteriorly subluxated lens. After removal of the subluxated lens, a suture supported posterior chamber IOL was implanted. Postoperative complication of cerebral venous thrombosis following general anaesthesia was managed with high doses of pyridoxine special diet and drugs.

  14. Location of the popliteal artery and its relationship with the vascular risk in the suture of the posterior horn of the lateral meniscus.

    Science.gov (United States)

    Sanz-Pérez, M; García-Germán, D; Ruiz-Díaz, J; Navas-Pernía, I; Campo-Loarte, J

    2015-01-01

    The proximity of the posterior horn of the lateral meniscus to the popliteal artery determines a risk of vascular injury in its suture. The aim of this study is to determine the location of the popliteal artery, and to establish the minimal distance from the posterior wall of the lateral meniscus to the artery, the common peroneal nerve (CPN), and its correlation to other variables. A total of 102 magnetic resonance studies were retrospectively reviewed from patients undergoing surgery at our institution. The axial section where the lateral meniscus could be clearly defined was selected, and the measurements were performed. The artery lay laterally to the midline in 94% of the cases. The minimal mean distance from the posterior wall of the lateral meniscus to the popliteal artery was 1.01cm. (0.32-1.74, SD: 0.304). The minimal mean distance to the CPN was 1.74cm. (0.75-2.87, SD: 0.374). No association was found between the minimal mean distance from the posterior wall to the popliteal artery with the height, weight, BMI, the lateral meniscus diameter, or the tibial plateau diameter. An association was found between the distance from the posterior wall to the CPN with the weight and the BMI. The proximity of the posterior horn to the popliteal artery should be considered when performing sutures. This distance is within the recommended depth for all-inside meniscus repair devices. This distance is not related to height, weight, BMI, lateral meniscus nor tibial plateau diameters. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  15. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  16. Transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens in aphakic nonvitrectomized eyes

    Directory of Open Access Journals (Sweden)

    Siddharth Agrawal

    2015-01-01

    Full Text Available Purpose: To evaluate the outcome of transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens (PCIOL in aphakia in nonvitrectomized eyes. Materials and Methods: Patients with postcataract surgery aphakia, trauma with posterior capsule injury, subluxated crystalline lens, and per operative complications where sulcus implantation was not possible were included over a 1-year period. Scleral fixation of acrylic hydrophilic PCIOL was performed according to the described technique, and the patients were evaluated on the day 1, 3, 14, and at 3 and 12 months postoperatively for IOL centration, pseudophakodonesis, change in best-corrected visual acuity (BCVA, and any other complications. Results: Out of twenty-nine eyes of 24 patients, who completed the study, 25 (86.2% eyes had improved, 2 (6.9% eyes showed no change, and 2 (6.9% eyes had worsening of BCVA. Three (10.3% eyes developed postoperative complications. A significant improvement in mean BCVA (P < 0.0001 was observed after the procedure. Mean duration of follow-up was 26.2 months (range 22–35 months. Conclusion: The use of closed loop haptic acrylic IOL for scleral fixation appears to be safe and effective alternative to conventional scleral fixated polymethyl methacrylate intraocular lenses.

  17. [Edematous decompensation of the cornea after silicon implant of the posterior chamber in phakic eyes in myopia].

    Science.gov (United States)

    Marcon, G B; Galan, A; Rappo, G; Altafini, R; Zanotto, D; Carlentini, S

    1996-01-01

    The authors report a case of a girl operated with a silicon IOL in the posterior chamber for the correction of myopia in phakic eye. One year after surgery there was a total bilateral corneal decompensation which required corneal transplantation. The possible hypothesis of the damage are discussed.

  18. Air-Assisted Descemet Stripping Automated Endothelial Keratoplasty with Posterior Chamber Fixation of an Aphakic Iris‑Claw Lens

    Directory of Open Access Journals (Sweden)

    Farid Karimian

    2010-01-01

    Full Text Available Endothelial keratoplasty (EK is the most exciting recent development in corneal transplantation. It has experienced surprisingly rapid growth in a very short period of time. One of the indications for EK is pseudophakic bullous keratopathy. However, concomitant intraocular lens (IOL exchange, if indicated, may prove challenging. Some surgeons routinely perform IOL exchange with a scleral-fixated posterior chamber IOL, together with Descemet′s stripping endothelial keratoplasty (DSEK; however, this combined procedure is time-consuming, difficult and fraught with complications. Another option is aphakic Artisan IOL fixation, but this is usually not acceptable because of the increased risk of endothelial cell loss and difficulty in filling the anterior chamber with the air bubble. Herein, we introduce a new technique for IOL exchange with an aphakic Artisan IOL fixated posterior to the iris, combined with DSEK. This surgical technique was designed to preserve anterior segment anatomic features as much as possible.

  19. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  20. Subluxation of iris-sutured intraocular lenses and results of a closed chamber technique for repositioning after penetrating keratoplasty.

    Science.gov (United States)

    Jabbur, Nada S; Akpek, Esen Karamursel; Stark, Walter J

    2005-05-01

    To describe subluxation of iris-fixated intraocular lenses (IOLs) after penetrating keratoplasty (PK) as a postoperative complication and report the long-term outcomes of a closed-chamber refixation technique used in the management. This was a retrospective, noncomparative interventional case series in which 19 consecutive patient charts with a subluxated iris-fixated IOL after PK were retrospectively reviewed. Fourteen of the patients underwent surgery using a closed-chamber refixation technique. These patients were evaluated for visual outcome and surgical complications associated with the procedure. In 13 patients, postoperative follow-up was available. In all 13 cases, the fixated IOL appeared stable and remained well positioned during a follow-up period of 56 months (range, 6-122). All patients (100%) achieved improved uncorrected visual acuity. The postoperative visual acuity ranged from 20/20 to 20/100 with a mean of 20/40. Vitreous hemorrhage occurred in 1 patient, and an additional patient required a second surgery using the same technique. Both of these patients did well with a final visual acuity of 20/40 and 20/50, respectively. Subluxation of iris-fixated IOL after PK can occur as a postoperative complication. The technique that we herein describe enables secure refixation of subluxated IOLs and yields favorable long-term results.

  1. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes),

  2. Trabeculectomy combined with deep sclerectomy and scleral flap suture tension adjustment under an anterior chamber maintainer: a new modification of trabeculectomy.

    Science.gov (United States)

    Kayikcioglu, Ozcan R; Emre, Sinan; Kaya, Ziya

    2010-06-01

    The objective of this study was to investigate the efficacy and safety of trabeculectomy combined with deep sclerectomy in patients with primary open angled glaucoma (POAG) and to compare the results with those from conventional trabeculectomy. In the study 12 eyes of 10 patients operated with trabeculectomy combined with deep sclerectomy (Group I) and 16 eyes of 16 patients operated with conventional trabeculectomy surgery (Group II) were included. In the described form of combined deep sclerectomy with the trabeculectomy technique the superficial scleral flap was sutured with 10/0 monofilament, the number and tension of sutures were adjusted according to the outflow dynamics, under the scleral flap, of balanced salt solution (BSS) provided by an anterior chamber maintainer. In groups I and II all the patients were male POAG cases with mean ages of 60.0 +/- 19.4 and 67.0 +/- 7.1 years, respectively. The mean follow-up periods were 8.3 +/- 3.5 months for group I and 16.6 +/- 7.0 months for group II. Preoperative mean IOP were 29.7 +/- 8.3 and 29.1 +/- 12.8 mmHg mmHg, and average topical antiglaucomatous medications were 2.9 +/- 0.7 and 2.7 +/- 1.1 for groups I and II, respectively. Postoperatively mean IOP measurements were reduced in groups I and II to 10.5 +/- 2.9 vs. 9.6 +/- 4.8 mmHg at 1 week, 13.7 +/- 5.6 vs. 16.0 +/- 9.8 at 1st month, 12.3 +/- 6.4 vs. 17.3 +/- 8.0 at 3rd month, 11.0 +/- 4.1 vs. 15.3 +/- 5.8 at 6th month, 10.8 +/- 1.6 vs. 16.1 +/- 4.4 at 12th month, and 11.0 +/- 1.0 vs. 16.7 +/- 5.0 at 18th month. Statistical analysis revealed that mean postoperative IOP measurements for group I were significantly lower than for group II for all measurements except the first week (P < 0.05). At 12th month, the complete (IOP <22 mmHg without medication) and qualified (IOP <22 mmHg with medication) success rates were 83.3 and 100% for group I and 63.6 and 90.9% for group II. Postoperatively at 12th month, the mean number of antiglaucoma medications had fallen to

  3. Sutureless glueless intrascleral fixation of posterior chamber intraocular lens: Boon for aphakic

    Directory of Open Access Journals (Sweden)

    Nagendra Shekhawat

    2017-01-01

    Full Text Available Purpose: To report results of intrascleral fixation of 3-piece IOL without the help of suture and glue. Methods: Study included intrascleral fixation of haptic in 50 eyes by T-fixation technique. Preoperative and postoperative visual acuity, slit lamp and fundus examination, applanation tonometry, keratometry, biometry, optical coherence tomography, Scheimpflug imaging were done for extensive evaluation. Qualitative and quantitative data were summarized in the form of proportion and mean and standard deviation, respectively. The significance of difference was measured by Chi-square test or unpaired t-test or ANOVA whichever is appropriate. P < 0.05 was considered as statistically significant. Results: There was one case in which haptic broke during handshake maneuver and another IOL was required. Postoperative complications included corneal edema (4%, increased intraocular pressure (6%, cystoid macular edema (2%, decentration (4%, and dislocation (2%, which were all managed to the level of good visual recovery. There was no significant change in corneal astigmatism. There was significant change found in best-corrected visual acuity and uncorrected visual acuity after surgery. Conclusion: This modified technique seems to be a good alternative in IOL implantation in eyes with deficient capsules in view of the decrease in the learning time and surgical time and risk for complications.

  4. Low-cost high-volume extracapsular cataract extraction with posterior chamber intraocular lens implantation in Nepal.

    Science.gov (United States)

    Ruit, S; Tabin, G C; Nissman, S A; Paudyal, G; Gurung, R

    1999-10-01

    To improve current clinical practices and ways of thinking about the problem of curable Third-World blindness resulting from cataract. A two-site prospective, nonrandomized, comparative clinical trial. Patients from 2 distinct surgical venues underwent cataract surgery following the same carefully outlined protocol: 62 consecutive cases from the Tilganga Eye Centre in Katmandu, Nepal, and 207 cases from a remote eye camp in rural Chaughada, Nepal. Extracapsular cataract extraction with posterior chamber intraocular lens (IOL) implantation surgery using a technique developed by Dr. Sanduk Ruit of the Tilganga Eye Centre in conjunction with the Medical Directorate of the Fred Hollows Foundation of Australia. Also presented is the teaching method used to help make local doctors proficient in this technique. Visual acuity recorded at 2 months after surgery as well as surgical complications. Preoperative visual acuities for the 62 patients from the Tilganga Eye Centre ranged from 20/60 to light perception only (4 patients were untested). At 2 months after surgery, 87.1% had a best-corrected visual acuity of 20/60 or better. There were zero major surgical complications reported from the Tilganga group. Of the 207 patients at the Chaughada eye camp, preoperative visual acuities (recorded for 177 [85.5%]) ranged from 20/200 or greater to light perception only. One hundred eighty-nine (91.3%) of the patients returned for an examination at 2 months after surgery, at which time 54.5% had an uncorrected visual acuity of 20/60 or greater, improving to 74.1% with correction. There were six (2.9%) surgical complications documented at Chaughada. Because the average operative time using the technique presented here is less than 10 minutes per case and the cost per surgery is less than $20, the surgical results are significant in addressing the massive problem of cataract blindness in the Third World. With some changes in preoperative care, a simplified surgical technique, the

  5. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  6. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  7. HANGING BY A THREAD: THE LONG-TERM EFFICACY AND SAFETY OF TRANSSCLERAL SUTURED INTRAOCULAR LENSES IN CHILDREN (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    Science.gov (United States)

    Buckley, Edward G.

    2007-01-01

    Purpose To evaluate the long-term efficacy, safety, and advisability of using transscleral sutured posterior chamber intraocular lenses (IOLs) in pediatric patients with no capsular support and to determine whether 10-0 polypropylene suture should be used for this purpose. Methods A long-term retrospective interventional case series review of 33 eyes of 26 patients who had a sutured IOL at Duke University Eye Center were evaluated for the intraoperative surgical risks, postoperative visual and refractive outcomes, and the number, type, and severity of the postoperative complications. In addition, a survey of pediatric ophthalmologists’ experience with suture breakage was performed. Results Postoperative visual acuity was significantly improved after surgery (P subluxation of the IOL secondary to spontaneous 10-0 polypropylene suture breakage at 3.5, 8, and 9 years after surgery. A survey of pediatric ophthalmologists revealed 10 similar cases (mean, 5 years after surgery). Conclusion Transscleral fixation of an IOL in a child appears to be a safe and effective procedure provided that the suture material used is stable enough to resist significant degradation over time. Caution should be exercised in the use of 10-0 polypropylene suture to fixate an IOL to the sclera in children, and an alternative material or size should be considered. PMID:18427618

  8. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Shimizu, Kimiya

    2012-06-01

    A modified implantable collamer lens (ICL) with a central hole (diameter, 0.36 mm), a "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study was to investigate the fluid dynamic characteristics of aqueous humour in a Hole-ICL using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V5 (Mentor Graphics Corp.). For the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. Both ICLs were -9.0 diopters (D) and 12.0 mm in length, with an optic of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μl/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated, and trajectory analysis was performed. The flow velocity 0.25 mm in front of the centre of the crystalline lens was 1.52 × 10(-1) mm/sec for the Hole-ICL and 1.21 × 10(-5) mm/sec for the conventional ICL. Outward flow from the hole in the Hole-ICL was confirmed by trajectory analysis. These results suggest that Hole-ICLs improve the circulation of aqueous humour to the anterior surface of the crystalline lens.

  9. Nueva variante de abordaje al surco ciliar en la fijación transescleral de lentes de cámara posterior New variant of approach to the ciliary sulcus in the transcleral fixation of posterior chamber lens

    Directory of Open Access Journals (Sweden)

    Ileana Vila Dópico

    2002-06-01

    Full Text Available Se expone una variante de abordaje al surco ciliar para la fijación del lente intraocular de cámara posterior, que está a nuestro alcance, en pacientes en que no existe soporte capsular o este es insuficiente. Se describe la técnica. Se realizó en 17 pacientes de los que se obtuvo mejoría visual en todos los casos (20/50-20/20 con un seguimiento promedio de 12 meses. Esta variante tiene la ventaja de evitar el paso de la aguja por el surco ciliar a ciegas, pues se utiliza el abordaje a través de la esclera y con ello evitamos dañar estructuras oculares aledañas evitando el riesgo de complicaciones por lo que se logra la recuperación anatómica y funcional en todos los casos.A variant to approach the ciliary sulcus for fixating the posterior chamber intraocular lens, which is within our reach, in patients with insufficient or no capsular support, is explained. The technique is described here and it was applied to 17 patients. Visual improvement was obtained in all cases (20/50-20/20 with an average follow-up of 12 months. This variant allows to prevent the blind passage of the needle through the ciliary sulcus, since it is approached via the sclera, avoiding to damage adjoining ocular structures and to have complications, and making possible the anatomic and functional recovery of all patients.

  10. The hidden X suture: a technical note on a novel suture technique for alveolar ridge preservation.

    Science.gov (United States)

    Park, Jung-Chul; Koo, Ki-Tae; Lim, Hyun-Chang

    2016-12-01

    The present study investigated the impact of 2 different suture techniques, the conventional crossed mattress suture (X suture) and the novel hidden X suture, for alveolar ridge preservation (ARP) with an open healing approach. This study was a prospective randomized controlled clinical trial. Fourteen patients requiring extraction of the maxillary or mandibular posterior teeth were enrolled and allocated into 2 groups. After extraction, demineralized bovine bone matrix mixed with 10% collagen (DBBM-C) was grafted and the socket was covered by porcine collagen membrane in a double-layer fashion. No attempt to obtain primary closure was made. The hidden X suture and conventional X suture techniques were performed in the test and control groups, respectively. Cone-beam computed tomographic (CBCT) images were taken immediately after the graft procedure and before implant surgery 4 months later. Additionally, the change in the mucogingival junction (MGJ) position was measured and was compared after extraction, after suturing, and 4 months after the operation. All sites healed without any complications. Clinical evaluations showed that the MGJ line shifted to the lingual side immediately after the application of the X suture by 1.56±0.90 mm in the control group, while the application of the hidden X suture rather pushed the MGJ line slightly to the buccal side by 0.25±0.66 mm. It was demonstrated that the amount of keratinized tissue (KT) preserved on the buccal side was significantly greater in the hidden X suture group 4 months after the procedure ( P preserving horizontal width and minimizing vertical reduction in comparison to X suture ( P preserving the width of KT and the dimensions of the alveolar ridge after ARP.

  11. Suture midface suspension

    Directory of Open Access Journals (Sweden)

    Murthy Rachna

    2006-11-01

    Full Text Available Abstract Objective To describe a simple and effective facelift technique useful as an adjunct to other oculoplastic procedures Methods Retrospective, non-comparative case series. Thirty five patients undergoing suture midface suspension from 1998 to 2000. Suspension sutures were passed from the nasolabial fold to the temporalis fascia to elevate the midface and the corner of the mouth. Results A satisfactory and stable outcome is obtained in 2 years of follow up. Conclusion Suture midface suspension is a safe and effective technique for the management of midface descent.

  12. The Strength of Transosseous Medial Meniscal Root Repair Using a Simple Suture Technique Is Dependent on Suture Material and Position.

    Science.gov (United States)

    Robinson, James R; Frank, Evelyn G; Hunter, Alan J; Jermin, Paul J; Gill, Harinderjit S

    2018-03-01

    A simple suture technique in transosseous meniscal root repair can provide equivalent resistance to cyclic load and is less technically demanding to perform compared with more complex suture configurations, yet maximum yield loads are lower. Various suture materials have been investigated for repair, but it is currently not clear which material is optimal in terms of repair strength. Meniscal root anatomy is also complex; consisting of the ligamentous mid-substance (root ligament), the transition zone between the meniscal body and root ligament; the relationship between suture location and maximum failure load has not been investigated in a simulated surgical repair. (A) Using a knottable, 2-mm-wide, ultra-high-molecular-weight polyethylene (UHMWPE) braided tape for transosseous meniscal root repair with a simple suture technique will give rise to a higher maximum failure load than a repair made using No. 2 UHMWPE standard suture material for simple suture repair. (B) Suture position is an important factor in determining the maximum failure load. Controlled laboratory study. In part A, the posterior root attachment of the medial meniscus was divided in 19 porcine knees. The tibias were potted, and repair of the medial meniscus posterior root was performed. A suture-passing device was used to place 2 simple sutures into the posterior root of the medial meniscus during a repair procedure that closely replicated single-tunnel, transosseous surgical repair commonly used in clinical practice. Ten tibias were randomized to repair with No. 2 suture (Suture group) and 9 tibias to repair with 2-mm-wide knottable braided tape (Tape group). The repair strength was assessed by maximum failure load measured by use of a materials testing machine. Micro-computed tomography (CT) scans were obtained to assess suture positions within the meniscus. The wide range of maximum failure load appeared related to suture position. In part B, 10 additional porcine knees were prepared. Five

  13. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  14. Suture Coding: A Novel Educational Guide for Suture Patterns.

    Science.gov (United States)

    Gaber, Mohamed; Abdel-Wahed, Ramadan

    2015-01-01

    This study aims to provide a helpful guide to perform tissue suturing successfully using suture coding-a method for identification of suture patterns and techniques by giving full information about the method of application of each pattern using numbers and symbols. Suture coding helps construct an infrastructure for surgical suture science. It facilitates the easy understanding and learning of suturing techniques and patterns as well as detects the relationship between the different patterns. Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. The arrangement is fixed as 1-3-5-7 and a-c-e-g on one side (whether right or left) and as 2-4-6-8 and b-d-f-h on the other side. Needle placement must start from number 1 or letter "a" and continue to follow the code till the end of the stitching. Some rules are created to be adopted for the application of suture coding. A suture trainer containing guide points that simulate the coding process is used to facilitate the learning of the coding method. (120) Is the code of simple interrupted suture pattern; (ab210) is the code of vertical mattress suture pattern, and (013465)²/3 is the code of Cushing suture pattern. (0A1) Is suggested as a surgical suture language that gives the name and type of the suture pattern used to facilitate its identification. All suture patterns known in the world should start with (0), (A), or (1). There is a relationship between 2 or more surgical patterns according to their codes. It can be concluded that every suture pattern has its own code that helps in the identification of its type, structure, and method of application. Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. Coding methods facilitate suture patterns learning process. The use of suture coding can be a good

  15. Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

    Science.gov (United States)

    Kawamorita, Takushi; Shimizu, Kimiya; Shoji, Nobuyuki

    2016-04-01

    A modified implantable collamer lens (ICL) with a central hole with a diameter of 0.36 mm, referred to as a hole-ICL, was created to improve aqueous humour circulation. The aim of this study is to investigate the ideal hole size in a hole-ICL from the standpoint of the fluid dynamic characteristics of the aqueous humour using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V 12.2 (Mentor Graphics Corp.). In the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with a conventional ICL (Model ICM, Staar Surgical) and a hole-ICL were used. The hole-ICL was -9.0 dioptres (D) and 12.0 mm in length, with an optic zone of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μL/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was calculated, and trajectory analysis was performed. With an increase in the central hole size, the velocity of the aqueous humour increased, with the peak velocity occurring at a diameter of approximately 0.4 mm. Once the diameter had increased above 0.4 mm, the velocity then decreased. The velocity difference between the cases of a central hole size of 0.1 mm and 0.2 mm was significant. The desirable central hole size was 0.2 mm or larger in terms of flow dynamics. The current model, based on a central hole size of 0.36 mm, was close to ideal. The optimisation of the hole size should be performed based on results from a long-term clinical study so as to analyse the incidence rate of secondary cataract and optical performance.

  16. Replacement for sutures.

    Science.gov (United States)

    1989-07-08

    Davis and Geek has introduced a blue tissue adhesive, Histoacryl, for use as a gentle alternative to stitches for children who need treatment for minor skin wounds. The company says that accident and emergency departments have found it provides an excellent alternative to sutures because there is no need for an anaesthetic nor a return visit to have the stitches removed. It takes away some of the trauma for the young patients and parents as well as the staff who treat them.

  17. Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.

    Science.gov (United States)

    Kocabey, Yavuz; Taşer, Omer; Hapa, Onur; Güçlü, Aycan; Bozdag, Ergun; Sünbüloglu, Emin; Doral, Mahmutnedim

    2011-02-01

    the purpose of this study was to compare the mechanical characteristics of meniscal repair fixation using horizontal sutures and two different diameter sutures under submaximal cyclic and load to failure test conditions. a 2-cm long anteroposterior vertical longitudinal incision was created in two groups of bovine medial menisci. Lesions were repaired using either #2-0 (Group 1), or #2 (Group 2) Fiberwire suture. Following repair, the lesion was extended through the posterior and anterior meniscal horns so that no tissue secured the repair site. Specimens underwent submaximal cyclic (5-50 N at 1 Hz for 500 cycles) and load to failure testing (5 mm/min crosshead speed) in a servo hydraulic device. Specimen failure mode was verified by the primary investigator. An alpha level of P meniscal tissue. Larger diameter suture provided superior mechanical meniscal fixation. if horizontal suture would be used in meniscal repair, the most suitable larger diameter suture should be used.

  18. Unravelling the molecular control of calvarial suture fusion in children with craniosynostosis

    Directory of Open Access Journals (Sweden)

    Morris C Phillip

    2007-12-01

    the metopic suture being most disparate. Finally, although calvarial bones are generally thought to grow without a cartilage precursor, we show histologically and by identification of cartilage-specific gene expression that cartilage may be involved in the morphogenesis of lambdoid and posterior sagittal sutures. Conclusion This study has provided further insight into the complex signalling network which controls human calvarial suture morphogenesis and craniosynostosis. Identified genes are candidates for targeted therapeutic development and to screen for craniosynostosis-causing mutations.

  19. Optimal suture anchor direction in arthroscopic lateral ankle ligament repair.

    Science.gov (United States)

    Yoshimura, Ichiro; Hagio, Tomonobu; Noda, Masahiro; Kanazawa, Kazuki; Minokawa, So; Yamamoto, Takuaki

    2017-05-26

    In this study, the distance between the insertion point of the suture anchors and posterior surface of the fibula during arthroscopic lateral ankle ligament repair was investigated on computed tomography (CT) images. The hypothesis of this study was that there is an optimal insertional direction of the suture anchor to avoid anchor-related complications. One hundred eleven ankles of 98 patients who had undergone three-dimensional CT scans for foot or ankle disorders without deformity of the fibula were assessed (59 males, 52 females; median age 25.5 years; age range 12-78 years). The shortest distance from the insertion point of the suture anchor to the deepest point of the fossa/top of the convex aspect of the fibula was measured on the axial plane, tilting from the longitudinal axis of the fibula at 90°, 75°, 60°, and 45°. The distance from the insertion point of the suture anchor to the posterior surface of the fibula was also measured in a direction parallel to the sagittal plane of the lateral surface of the talus on the axial plane, tilting from the longitudinal axis of the fibula at 90°, 75°, 60°, and 45°. The posterior fossa was observed in all cases on the 90° and 75° images. The distance from the insertion point to the posterior surface of the fibula in the parallel direction was 15.0 ± 3.4 mm at 90°, 17.5 ± 3.2 mm at 75°, 21.7 ± 3.3 mm at 60°, and 25.7 ± 3.6 mm at 45°. The posterior points in the parallel direction were located on the posterior fossa in 36.0% of cases at 90°, in 12.6% at 75°, and in 0.0% at 60° and 45°. The suture anchor should be directed from anterior to posterior at an angle of <45° to the longitudinal axis of the fibula, parallel to the lateral surface of the talus, to avoid passing through the fibula. Cohort study, Level III.

  20. Force sensing in surgical sutures

    NARCIS (Netherlands)

    T. Horeman (Tim); E.-J. Meijer (Evert-Jan); J.J. Harlaar (Joris Jan); J.F. Lange (Johan); J.J. van den Dobbelsteen (John); J. Dankelman (Jenny)

    2013-01-01

    textabstractThe tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to

  1. Force sensing in surgical sutures

    NARCIS (Netherlands)

    Horeman, T.; Meijer, E.J.; Harlaar, J.J.; Lange, J.F.; Van den Dobbelsteen, J.J.; Dankelman, J.

    2013-01-01

    The tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to describe the

  2. Bacterial adherence to polymethylmethacrylate posterior chamber IOLs

    Directory of Open Access Journals (Sweden)

    Tyagi Shalini

    2001-01-01

    Full Text Available Purpose: Bacterial adherence to intraocular lenses (IOLs has been incriminated in the pathogenesis of postoperative endophthalmitis. Staphylococcus epidermidis is the most common organism isolated. We studied the in-vitro adhesion of Staphylococcus epidermidis to Polymethylmethacrylate (PMMA IOLs and the effect of duration of exposure to adherence. Methods: Two groups of 10 IOLs each were incubated in Staphylococcus epidermidis suspension for 2 minutes and 20 minutes respectively. Adhesion of bacterial cells was determined by counting the number of viable bacteria attached to IOLs. Results: The mean bacterial adherence with 2 minutes incubation was 12,889 ± 7,150 bacteria / IOL and with 20 minutes incubation was 84,226 ± 35,024 bacteria/IOL (P< 0.01. Conclusion: Our results show that Staphylococcus epidermidis adheres to PMMA IOLs in vitro and the degree of adherence is less for shorter duration of exposure. We conclude that viable bacteria irreversibly adherent to IOLs may play a role in the pathogenesis of postoperative endophthalmitis. Shorter duration of operative manipulation and exposure to contaminating sources may decrease the chances of postoperative endophthalmitis.

  3. Force sensing in surgical sutures.

    Directory of Open Access Journals (Sweden)

    Tim Horeman

    Full Text Available The tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to describe the design and evaluation of the Stitch Force (SF sensor and the Hook-In Force (HIF sensor. These sensors were developed to measure the force on a tensioned suture inside a closed incision and to measure the pulling force used to close the incision. The accuracy of both sensors is high enough to determine the relation between the force in the thread of a stitch and the pulling force applied on the suture by the physician. In a pilot study, a continuous suture of 7 stitches was applied on the fascia of the abdominal wall of multiple pigs to study this relationship. The results show that the max force in the thread of the second stitch drops from 3 (SD 1.2 to 1 (SD 0.3 newton after the 4(th stitch was placed. During placement of the 5(th, 6(th and 7(th stitch, the force in the 2(nd stitch was not influenced anymore. This study indicates that in a continuous suture the force in the thread remains constant up to more than 3 stiches away from the pulled loose end of the suture. When a force feedback tool is developed specially for suturing in surgery on patients, the proposed sensors can be used to determine safety threshold for different types of tissue and sutures.

  4. Force sensing in surgical sutures.

    Science.gov (United States)

    Horeman, Tim; Meijer, Evert-Jan; Harlaar, Joris J; Lange, Johan F; van den Dobbelsteen, John J; Dankelman, Jenny

    2013-01-01

    The tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to describe the design and evaluation of the Stitch Force (SF) sensor and the Hook-In Force (HIF) sensor. These sensors were developed to measure the force on a tensioned suture inside a closed incision and to measure the pulling force used to close the incision. The accuracy of both sensors is high enough to determine the relation between the force in the thread of a stitch and the pulling force applied on the suture by the physician. In a pilot study, a continuous suture of 7 stitches was applied on the fascia of the abdominal wall of multiple pigs to study this relationship. The results show that the max force in the thread of the second stitch drops from 3 (SD 1.2) to 1 (SD 0.3) newton after the 4(th) stitch was placed. During placement of the 5(th), 6(th) and 7(th) stitch, the force in the 2(nd) stitch was not influenced anymore. This study indicates that in a continuous suture the force in the thread remains constant up to more than 3 stiches away from the pulled loose end of the suture. When a force feedback tool is developed specially for suturing in surgery on patients, the proposed sensors can be used to determine safety threshold for different types of tissue and sutures.

  5. The history of barbed sutures.

    Science.gov (United States)

    Ruff, Gregory L

    2013-09-01

    Ligatures have been used for millennia to close wounds. Sterilization and synthetic polymers that degrade in a commensurate fashion with wound healing have been the most significant improvements in these age-old devices. However, the constricting loop of a traditional suture and subsequent ischemia ("approximate, don't strangulate") still account for the most common cause of wound dehiscence-necrosis. Inspired by the quill of the North American porcupine, I envisioned a bidirectional array of barbs that could secure tissue without relying on constricting loops. One set of barbs could anchor the other. In this article, I document the development process of these barbed sutures from concept to patent to manufacture and US Food and Drug Administration approval. Knotless, strong, and easy to place, barbed sutures could foreseeably supplant conventional sutures, particularly as endoscopic procedures become more common. They also offer the intriguing potential to suspend ptotic tissues without surgical intervention.

  6. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    1999-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  7. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  8. Longitudinal parallel compression suture to control postopartum hemorrhage due to placenta previa and accrete.

    Science.gov (United States)

    Li, Guang-Tai; Li, Xiao-Fan; Wu, Baoping; Li, Guangrui

    2016-04-01

    To assess the efficacy and safety of longitudinal parallel compression suture to control heavy postpartum hemorrhage (PPH) in patients with placenta previa/accreta. Fifteen women received a longitudinal parallel compression suture to stop life-threatening PPH due to placenta previa with or without accreta during cesarean section. The suture apposed the anterior and posterior walls of the lower uterine segment together using an absorbable thread A 70-mm round needle with a Number-1 absorbable thread was used. The point of needle entry was 1 cm above the upper margin of the cervix and 1 cm from the right lateral border of the lower segment of the anterior wall. The suture was threaded through the uterine cavity to the serosa of the posterior wall. Then, it was directed upward and threaded from the posterior to the anterior wall at ∼1-2 cm above the upper boundary of the lower uterine segment and 3-cm medial to the right margin of the uterus. Both ends of the suture were tied on the anterior aspect of uterus. The left side was sutured in the same way. The success rate of the procedure was 86.7% (13/15). Two of 15 cases were concurrently administered gauze packing and achieved satisfactory hemostasis. All patients resumed a normal menstrual flow, and no postoperative anatomical or physiological abnormalities related to the suture were observed. Three women achieved further pregnancies after the procedure. Longitudinal parallel compression suture is a safe, easy, effective, practical, and conservative surgical technique to stop intractable PPH from the lower uterine segment, particularly in women who have a cesarean scar and placenta previa/accreta. Copyright © 2016. Published by Elsevier B.V.

  9. Ameloblastin inhibits cranial suture closure by modulating MSX2 expression and proliferation.

    Directory of Open Access Journals (Sweden)

    Phimon Atsawasuwan

    Full Text Available Deformities of cranial sutures such as craniosynostosis and enlarged parietal foramina greatly impact human development and quality of life. Here we have examined the role of the extracellular matrix protein ameloblastin (Ambn, a recent addition to the family of non-collagenous extracellular bone matrix proteins, in craniofacial bone development and suture formation. Using RT-PCR, western blot and immunohistochemistry, Ambn was localized in mouse calvarial bone and adjacent condensed mesenchyme. Five-fold Ambn overexpression in a K14-driven transgenic mouse model resulted in delayed posterior frontal suture fusion and incomplete suture closure. Moreover, Ambn overexpressor skulls weighed 13.2% less, their interfrontal bones were 35.3% thinner, and the width between frontal bones plus interfrontal suture was 14.3% wider. Ambn overexpressing mice also featured reduced cell proliferation in suture blastemas and in mesenchymal cells from posterior frontal sutures. There was a more than 2-fold reduction of Msx2 in Ambn overexpressing calvariae and suture mesenchymal cells, and this effect was inversely proportionate to the level of Ambn overexpression in different cell lines. The reduction of Msx2 expression as a result of Ambn overexpression was further enhanced in the presence of the MEK/ERK pathway inhibitor O126. Finally, Ambn overexpression significantly reduced Msx2 down-stream target gene expression levels, including osteogenic transcription factors Runx2 and Osx, the bone matrix proteins Ibsp, ColI, Ocn and Opn, and the cell cycle-related gene CcnD1. Together, these data suggest that Ambn plays a crucial role in the regulation of cranial bone growth and suture closure via Msx 2 suppression and proliferation inhibition.

  10. Single-suture scleral fixation of subluxated foldable intraocular lenses.

    Science.gov (United States)

    Yarangumeli, Alper; Alp, Mehmet Numan; Kural, Gulcan

    2012-01-01

    To evaluate the results of single-suture scleral fixation of subluxated foldable intraocular lenses (IOL) in eyes with sufficient residual capsular support. The results of IOL repositioning by single-suture scleral fixation in 6 eyes of 6 patients with IOL subluxation were included. All subluxated IOLs were single-piece hydrophilic acrylic. Subluxation resulted from posterior capsule tears in 3 eyes, zonular dialyses in 2 eyes, and zonular dialysis with a capsulorhexis tear in 1 eye. A similar technique was used in all eyes in which one haptic was externalized through a superior clear corneal incision and tied with a Pair-PAK 10-0 polypropylene suture, and was finally retracted and fixated behind the iris close to the ciliary sulcus at the 12:00 meridian. All patients were followed up for at least 6 months. Best-corrected visual acuities ranged between finger counting and 20/70 (mean logMAR 1.02±0.64) preoperatively, and between 20/100 and 20/20 (mean logMAR 0.22±0.26) at the final postoperative visit. All IOLs remained centered and no significant postoperative complications were encountered except for an IOL tilt which resulted in a considerable oblique astigmatism in one eye. Subluxated foldable IOLs may safely be repositioned and secured with a single scleral fixation suture in selected cases with adequate amount of capsular remnants.

  11. Relationship of squamosal suture to asterion in pongids (Pan): relevance to early hominid brain evolution.

    Science.gov (United States)

    Holloway, R L; Shapiro, J S

    1992-11-01

    Based on 244 measurements of the relationship of the squamosal suture to the landmark asterion in 49 chimpanzee skulls, it is shown that in the normal lateral view the squamosal suture is very rarely inferior to asterion. In hominid crania, the squamosal suture is always well superior to asterion. Even in Pan, that part of the squamosal suture most homologous with the remnant found on the Hadar AL 162-28 Australopithecus afarensis hominid cranial fragment is very rarely inferior to asterion. Such variability suggests that Falk's (Nature 313:45-47, 1985) orientation of the Hadar specimen is incorrect; she places asterion superior to the position of the squamosal suture if projected endocranially. The implication for the brain endocast is that, however the fragment is oriented, the posterior aspect of the intraparietal (IP) sulcus is in a very posterior position relative to any chimpanzee brain. The distance from the posterior aspect of IP to occipital pole is twice as great in chimpanzee brain casts than on the Hadar AL 162-28 endocast, even though the chimpanzee brain casts are smaller in overall size. This suggests that brain reorganization, at least as exemplified as a reduction in primary visual striate cortex (area 17 of Brodmann), occurred early in hominid evolution, prior to any major brain expansion.

  12. Nonabsorbable versus absorbable sutures in large, hang-back medial rectus muscle recessions.

    Science.gov (United States)

    Awadein, Ahmed; Marsh, Justin D; Guyton, David L

    2016-06-01

    To investigate the value of nonabsorbable sutures in reducing the incidence of consecutive exotropia after large, "hang-back" medial rectus recessions. The medical records of patients who underwent medial rectus recession of ≥6.5 mm in individuals ≤2 years of age, or ≥7.0 mm in those >2 years were retrospectively reviewed. Patients were divided into two groups based on suture material used: absorbable, polyglactin 910 sutures (44 patients); nonabsorbable, polyester sutures (50 patients). Preoperative measurements, ductions, strabismus surgery, and postoperative results were analyzed. Inadequate anchoring of the medial rectus muscle was suspected when consecutive exotropia developed 4-7 weeks after surgery after initial satisfactory alignment and was confirmed if during reoperation the medial rectus muscle appeared recessed >2 mm beyond the originally intended recession. Consecutive exotropia due to inadequate anchoring of the medial rectus muscle occurred in 11 of 66 muscles (17%) in the absorbable suture group. The muscle was found 6-10 mm posterior to the intended recession. Limited duction in the field of action of the involved medial rectus muscle occurred in 9 of the 11 muscles (82%). None of the eyes with nonabsorbable sutures showed inadequate anchoring. The incidence of consecutive exotropia was higher in the absorbable suture group (30%) than in the nonabsorbable suture group (6%) (P < 0.005). Using nonabsorbable suture for large, hang-back medial rectus recessions greatly reduces the incidence of consecutive exotropia that can occur when absorbable suture dissolves. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  13. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber...

  14. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  15. Suture materials and suture techniques used in tendon repair.

    Science.gov (United States)

    Ketchum, L D

    1985-02-01

    Immediately after a tendon repair, the tendon contributes nothing to the strength of repair. During that time, the suture itself and suture technique are the sole contributors to the strength of repair. Although stainless steel is the strongest material that can be used at the time of repair, it has serious disadvantages. It is difficult to work with and makes a bulky knot. Conversely, all absorbable sutures become too weak too soon to be of value. At this time, nonabsorbable, synthetic fibers that are relatively strong, such as Supramid or prolene, are the most desirable materials available. Regarding suture techniques, the lateral trap and end-weave techniques produce the strongest repairs; however, the end-weave technique can only be used with tendon grafts and the lateral trap, though it can be used for end-to-end primary repairs. It is too bulky for use in the fingers and hand but is ideal for the forearm and wrist. In the hand and fingers, the strongest repair techniques available are the Bunnell, Kessler, and Mason-Allen; however, the Bunnell stitch is more strangulating to the microcirculation of the tendon than the latter two stitches; thus, it contributes to tendomalacia and gap formation. The simplest and least traumatic suture technique, though weakest at first, will allow tendon healing to proceed more rapidly. If such a repair is protected from tension by splinting the wrist and metacarpophalangeal joints in flexion during healing (while allowing controlled passive motion of the finger joints), there will be a rapid increase in tensile strength of the tendon juncture with minimal gap formation, as the repaired hand is progressively stressed up until about 90 days postrepair. At that point, strength plateaus and maximum stress can be applied to the repaired tendon. Somewhere between three and six weeks post-tendon repair, the suture material and technique become secondary to tendon healing as the primary provider of tensile strength to the tendon wound

  16. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture.

    LENUS (Irish Health Repository)

    Hennessey, D B

    2012-08-01

    A continuous running suture is the preferential method for abdominal closure. In this technique the suture is secured with an initial knot and successive tissue bites are taken. At each tissue bite, the needle is rotated through the tissue; in doing so, the suture can twist around the knot which acts as an anchor.

  17. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Graft Suturing for Lenticule Dislocation after Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Wai-Kwan Wu

    2011-01-01

    Full Text Available Purpose: To report the mid-term outcomes of graft suturing in a patient with lenticule dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK. Case Report: A 78-year old woman was found to have graft dislocation involving the nasal half of the cornea after uneventful DSAEK. Graft repositioning, refilling the anterior chamber with air, and placement of four full-thickness 10/0 nylon sutures over the detached area were performed two weeks after the initial surgery. The sutures were removed 6 weeks later. Serial specular microscopy and anterior segment optical coherence tomography were performed. At 18 months, there was good lenticule apposition and a clear graft. Conclusion: Anchoring sutures seem to be effective for management of graft detachment following DSAEK.

  19. Horizontal suture placement influences meniscal repair fixation strength.

    Science.gov (United States)

    Kocabey, Yavuz; Taser, Omer; Nyland, John; Ince, Haluk; Sahin, Feyzi; Sunbuloglu, Emin; Baysal, Gokhan

    2013-03-01

    This in vitro biomechanical study investigated the influence of horizontal suture placement distance from the medial meniscal lesion repair site on fixation characteristics during submaximal cyclic and load to failure test conditions. Eighteen cadaveric (20-45 years of age) medial menisci with intact joint capsules were harvested within 24-48 h after death and divided into two groups of 9 specimens each for biomechanical testing. A 2.0-cm-long antero-posterior vertical longitudinal lesion was created with a #15 scalpel 2.0-3.0 mm from the outer edge of each meniscus. Menisci were repaired using #2-0 suture material with two horizontal suture loops placed either 1.0 mm (Group 1) or 3.0 mm (Group 2) from the lesion site. Following repair, the lesion was extended completely through the meniscal horns so that no tissue secured the repair, only the two horizontal suture loops representing a "worst-case" testing scenario. Following repair, specimens were placed in a servo hydraulic device using a pair of 1.2-mm-diameter steel wire loops and underwent submaximal cyclic loading between 5 and 50 N (1 Hz) for 500 cycles prior to load to failure testing (5 mm/min crosshead speed, 20 Hz data collection). An alpha level of P lesion displayed superior repair fixation than sutures placed closer to the lesion. The superior biomechanical meniscal repair fixation provided by capturing greater tissue volume may enable safe earlier participation in functional exercise activities. Studies are needed to verify these findings in vivo.

  20. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  3. [Laparoscopic suture or open suture in perforated duodenal ulcer].

    Science.gov (United States)

    Nicolau, A E; Ionescu, G; Iordache, F; Mehic, R; Spătaru, A

    2002-01-01

    Between Nov. 1994-Jan. 2001 we performed laparoscopic suture with omentoplasty of perforated duodenal ulcer (PDU) in 51 patients out of 56 it was intended (this constituted the laparoscopic group--LG). The selection criteria were young patients, age < 40 years, no associated diseases, onset of the operation under 12 hours from the occurrence of the perforation, absence of clear ulcer history. In the same period, we performed an open suture based on the same criteria in 105 patients (open group--OP). The results showed a difference between needed analgesia (2.8 days for LG vs. 5.2 days for OG) and a hospital stay of 6.1 days in LG vs. 7.7 days in OG. The incidence of postoperative complications was 5.88% in the LG and 7.61% in the OG with 1.96% and respective 1.90% reoperation rate. In conclusion laparoscopic suture of PDU with associated postoperative modern therapy of ulcer disease could be the treatment of choice in young patients.

  4. Symbol "&" suture to control atonic postpartum hemorrhage with placenta previa accreta.

    Science.gov (United States)

    Li, Guang Tai; Li, Xiao Fan; Liu, Ya Jing; Li, Wei; Xu, Hong Mei

    2015-02-01

    To evaluate the efficacy and safety of a symbol "&" compression suture technique in controlling severe atonic postpartum hemorrhage with placenta previa accreta during cesarean delivery. Nine women with heavy postpartum bleeding from uterine inertia and placenta previa percret, which did not react to conventional initial management protocols, were underwent the suture in the shape of symbol "&" in China Meitan General Hospital. The suture procedure was to staple the anterior and posterior walls (of the lower uterine segment as well as corpus uterus) together using number 1 chromic catgut, with a cross at about 2 cm above the upper boundary of lower uterine segment. Symbol "&" compression suture was capable of stanching the postpartum hemorrhage immediately in all nine women. None of these patients developed complications related to this method. Subsequent pregnancies after the suture were occurred in two women and delivered with repeat cesarean section. Symbol "&" compression suture is a simple, safe and highly effective technique to control the treatment-resistant uterine atonic bleeding, particularly in previous cesarean scar at lower segment and placenta previa accreta.

  5. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. Posterior tibial tendon dysfunction by bone imprisonment | Zejjari ...

    African Journals Online (AJOL)

    The posterior tibial tendon showed longitudinal laceration was sutured and the internal retromalleolar canal was closed. The race and the freedom of the tendon were considered satisfactory by the end of surgery. The evolution was marked by the disappearance of pain, recovery of a satisfactory sport and professional ...

  10. Funnel compression suture: a conservative procedure to control postpartum bleeding from the lower uterine segment.

    Science.gov (United States)

    Li, G T; Li, G R; Li, X F; Wu, B P

    2016-07-01

    Bleeding from the lower uterine segment (LUS) during caesarean section remains a life-threatening obstetric problem, particularly in women with placenta praevia or partial placenta accreta in the LUS. Various conservative measures for the surgical treatment of postpartum haemorrhage have been studied for decades. In this paper we describe a funnel compression suture to staunch intractable bleeding from LUS for placenta praevia accreta. The suture brings the anterior and posterior walls of the LUS together using absorbable thread and was successful in the overwhelming majority of women. It is an easy, safe and effective conservative surgical treatment to stop severe bleeding of the LUS. © 2015 Royal College of Obstetricians and Gynaecologists.

  11. Robert Chambers

    NARCIS (Netherlands)

    K. Biekart (Kees); D.R. Gasper (Des)

    2013-01-01

    textabstractProfessor Robert Chambers is a Research Associate at the Institute of Development Studies (IDS), University of Sussex (Brighton, UK), where he has been based for the last 40 years, including as Professorial Research Fellow. He became involved in the field of development management in the

  12. Posterior ventricular anchoring neochordal repair of degenerative mitral regurgitation efficiently remodels and repositions posterior leaflet prolapse†

    Science.gov (United States)

    Woo, Y. Joseph; MacArthur, John W.

    2013-01-01

    OBJECTIVES Mitral valve repair techniques for degenerative disease typically entail leaflet resection or neochordal construction, which may require extensive resection, leaflet detachment/reattachment, reliance on diseased native chords or precise neochordal measuring. Occasionally, impaired leaflet mobility, reduced coaptation surface and systolic anterior motion (SAM) may result. We describe a novel technique for addressing posterior leaflet prolapse/flail, which both simplifies repair and addresses these issues. METHODS Fifty-four patients (age 62 ± 11 years) with degenerative MR underwent this new repair, 36 of whom minimally-invasively. A CV5 Gore-Tex suture was placed into the posterior left ventricular myocardium underneath the prolapsing segment as an anchor. This suture was then used to imbricate a portion of the prolapsed segment into the ventricle, creating a smooth, broad, non-prolapsed coapting surface on a leaflet with preserved mobility, additional neochordal support and posteriorly positioned enough to preclude SAM. RESULTS Repair was successful in all patients. The mean MR grade was reduced from +3.8 to +0.1 with 50 of 54 patients having zero MR and 4 of the 54 having trace or mild MR. All patients had proper antero-posterior location of the coaptation line of a mean length of 10.2 mm, and preserved posterior leaflet mobility. No patients had SAM or mitral stenosis. All patients were discharged and are currently doing well. CONCLUSION This new technique facilitated efficient single-suture repair of the prolapsed posterior leaflet mitral regurgitation without the need for resection or sliding annuloplasty. It precluded the need for precise neochordal measurement and preserved the leaflet coaptation surface. PMID:23449863

  13. Should nylon corneal sutures be routinely removed?

    Science.gov (United States)

    Jackson, H.; Bosanquet, R.

    1991-01-01

    Three groups of patients who had undergone cataract extraction through a corneal incision closed with 10/0 nylon sutures one, two, and three years previously were recalled to determine the incidence of suture related complications. Broken corneal sutures were found in 87.5% of patients after two years and 90% after three years and were causing symptoms in over half the patients. It is recommended that 10/0 nylon corneal sutures be routinely removed no later than one year after surgery. Images PMID:1751460

  14. Suppression chamber

    International Nuclear Information System (INIS)

    Goto, Hiroshi; Tsuji, Akio.

    1976-01-01

    Purpose: To miniaturize the storage tank of condensated water in BWR reactor. Constitution: A diaphragm is provided in a suppression chamber thereby to partition the same into an inner compartment and an outer compartment. In one of said compartments there is stored clean water to be used for feeding at the time of separating the reactor and for the core spray system, and in another compartment there is stored water necessary for accomplishing the depressurization effect at the time of coolant loss accident. To the compartment in which clean water is stored there is connected a water cleaning device for constantly maintaining water in clean state. As this cleaning device an already used fuel pool cleaning device can be utilized. Further, downcomers for accomplishing the depressurization function are provided in both inner compartment and outer compartment. The capacity of the storage tank can be reduced by the capacity of clean water within the suppression chamber. (Ikeda, J.)

  15. Allergy to Prolene Sutures in a Dural Graft for Chiari Decompression

    Directory of Open Access Journals (Sweden)

    Iahn Cajigas

    2015-01-01

    Full Text Available Allergy to Prolene suture is exceedingly rare with only 5 cases reported in the literature. There have been no such cases associated with neurosurgical procedures. Diagnosis is nearly always delayed in spite of persistent symptomatology. A 27-year-old girl with suspected Ehlers-Danlos, connective tissue disorder, underwent posterior fossa decompression for Chiari Type 1 malformation. One year later, the patient presented with urticarial rash from the neck to chest. Cerebrospinal fluid and blood testing, magnetic resonance imaging, and intraoperative exploration did not suggest allergic reaction. Eventually skin testing proved specific Prolene allergy. After suture material was removed, the patient no longer complained of pruritus or rash. This single case highlights the important entity of allergic reaction to suture material, namely, Prolene, which can present in a delayed basis. Symptomatology can be vague but has typical allergic characteristics. Multidisciplinary approach is helpful with confirmatory skin testing as a vital part of the workup.

  16. Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.

    Science.gov (United States)

    Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen

    2017-07-01

    Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P Screws in younger specimens (fewer than 70) resulted in significantly greater failure loads ( P screw fixation were either tunnel pullout (n = 6) or tendon rupture (n = 4). Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.

  17. Rupture of uterus treated with suture.

    Science.gov (United States)

    Klungsøyr, P; Kiserud, T

    1990-01-01

    Between August 1983 and August 1985, 63 patients in labor with uterine rupture were treated at Sidamo Regional Hospital, Yirgaalem, South Ethiopia, mainly by suture of the uterus. None of those operated on died. We recommend suturing as the treatment of choice. Hysterectomy is rarely indicated.

  18. Radiological assessment of skull base changes in children with syndromic craniosynostosis: role of ''minor'' sutures

    Energy Technology Data Exchange (ETDEWEB)

    Calandrelli, Rosalinda; D' Apolito, Gabriella; Gaudino, Simona; Stefanetti, Mariangela; Colosimo, Cesare [Universita Cattolica Sacro Cuore, Institute of Radiology, Rome (Italy); Massimi, Luca; Di Rocco, Concezio [Universita Cattolica Sacro Cuore, Institute of Neurosurgery, Rome (Italy)

    2014-10-15

    This study aims to identify the premature synostosis of ''major'' and ''minor'' sutures of the four ''sutural arches'' of the skull and to perform a morphometric analysis in children with syndromic craniosynostosis in order to evaluate changes in the skull base linked with premature suture synostosis. We reviewed multiplanar high-resolution CT images, implemented with 3D reconstructions, from 18 patients with complex syndromic craniosynostosis and compared them with 18 age-matched healthy subjects. We assessed the calvarial sutures and their extension to the skull base, and then we correlated specific types of synostosis with the size, shape and symmetry of the cranial fossae. We found a marked asymmetry of the skull base growth in all patients. The synostotic involvement around the coronal ring caused a reduction in the growth of the anterior and middle fossae. The size of the posterior cranial fossa was related not only to ''major'' but also to ''minor'' suture synostosis of the lambdoid and parieto-squamosal arches. Changes in the skull base and craniofacial axis symmetry are due to structural and functional relationships between ''major'' and ''minor'' skull sutures, suggesting a structural and functional relationship between the neurocranium and basicranium. The early recognition of prematurely closed skull base sutures may help clinicians and neurosurgeons to establish correct therapeutic approaches. (orig.)

  19. The Effect of Instrumentation on Suture Tensile Strength and Knot Pullout Strength of Common Suture Materials.

    Science.gov (United States)

    Johnson, Peter C; Roberts, Aaron D; Hire, Justin M; Mueller, Terry L

    2016-01-01

    To determine the effect of instrumentation of suture material on knot security and tensile strength. In all, 5 types of suture material were used; 10 knots were tied without any instrumentation and 10 knots were tied with a hemostat holding tension on the first throw while the second throw was made for each suture type. Each group was tested to failure with the maximum load and mode of failure recorded. The maximum load between groups of each suture type was compared; frequency of failure through knot slippage vs material fracture was also compared between groups. There was no significant difference observed in the maximum load to failure for any suture type between instrumented and noninstrumented groups. Additionally, there was no difference between any instrumented and noninstrumented groups for material failure vs failure due to knot slippage. Instrumentation of suture material during two-hand tying does not affect the strength of suture material or knot security. Published by Elsevier Inc.

  20. Comparison of Knotless Barbed Suture Versus Monofilament Suture in the Oral Cavity of Cats.

    Science.gov (United States)

    Durand, Corinne L

    2017-09-01

    The present study compares a knotless, barbed, absorbable suture material against a conventional monofilament absorbable suture material in oral mucosal wound closure. The parameters measured include time of closure and differences in healing at 2 and 4 weeks postoperatively. A prospective study comparing a knotless, barbed suture system with conventional absorbable sutures was undertaken in 19 cats. Nineteen cats had full mouth extractions performed. Following the extraction procedures, the incisions in the arcades (maxillary and mandibular) were apposed with the barbed, knotless suture system in a continuous pattern on one side and with a conventional smooth suture in an interrupted pattern on the other. Suturing times for each arcade were recorded. The material used to close the first side of each cat varied. Healing, dehiscence, and other complications were assessed at 2 and 4 weeks postoperatively. The average closure time (± standard deviation) per quadrant with conventional monofilament suture was 8.7 (±1.3) minutes, while barbed suture required an average of 5.1 (±1.1) minutes per quadrant to complete the suture. This difference (95% confidence interval) of 3.6 (±3.2-4.1) minutes per quadrant was statistically significant ( P < .001). Dehiscence and ranula-like swelling formation were noted as uncommon postoperative complications, but the differences were not significant between the groups. Barbed, knotless sutures resulted in faster closure times than conventional, simple interrupted, monofilament sutures with similar healing and complication rates. To the author's knowledge, there is no current literature comparing conventional absorbable monofilament sutures to a knotless, barbed, absorbable suture system for closure of oral mucosal incisions in cats.

  1. A new method for sex estimation from maxillary suture length in a Thai population

    Science.gov (United States)

    Sinthubua, Apichat; Ruengdit, Sittiporn; Das, Srijit

    2017-01-01

    Sex estimation is one of the crucial procedures in the biological profile identification of human skeletal remains. Knowing sex of unknown case can lead to accurate and appropriate methods for predicting age, stature, ancestry, or even personal identification. Skull is one of the most reliable one among other skeletons and it is usually retained for both archaeological and forensic contexts. Although many morphological features and metric measurements of skull have been studied for sexing, but to the best of our knowledge is no study on maxillary suture length for sex estimation. Therefore, this study aims to develop a new sex estimation method for a Thai population by determining three maxillary suture lengths: anterior, transverse, and posterior maxillary suture, by computerizing amount of pixel obtained from photographs of these sutures. The present study was conducted on 190 Thai bone samples of which 96 were males and 94 were females. Independent t test revealed statistically significant difference (P<0.01) between males and females in all maxillary suture measurements. Equations derived from prediction model, which required three maxillary suture lengths gave 76.8421% accuracy from the leave-one-out cross validation in estimating sex percentage accuracies in predicting sex from these equations, which were relatively moderate. This study provides a novel and objective sex estimation method for Thais. It suggests that maxillary suture length can be applied for sex estimation. The new computerized technique will contribute basis knowledge and method for sex estimation, especially when only base of skull is available in forensic circumstance. PMID:29354297

  2. Chamber transport

    International Nuclear Information System (INIS)

    Olson, Craig L.

    2001-01-01

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system

  3. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging.

    Science.gov (United States)

    Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won

    2017-11-01

    Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3-4.2%). Midpalatal suture was successfully split by MSE in late adolescents, and

  4. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging

    Directory of Open Access Journals (Sweden)

    Daniele Cantarella

    2017-11-01

    Full Text Available Abstract Background Mini-implant-assisted rapid palatal expansion (MARPE appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME. Maxillary Skeletal Expander (MSE is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Methods Fifteen subjects (mean age of 17.2 years; range, 13.9–26.2 years were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher’s exact test was used. Results Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS and at posterior nasal spine (PNS was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05. No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and

  5. A multicenter randomized controlled trial comparing absorbable barbed sutures versus conventional absorbable sutures for dermal closure in open surgical procedures.

    Science.gov (United States)

    Rubin, J Peter; Hunstad, Joseph P; Polynice, Alain; Gusenoff, Jeffrey A; Schoeller, Thomas; Dunn, Raymond; Walgenbach, Klaus J; Hansen, Juliana E

    2014-02-01

    Barbed sutures were developed to reduce operative time and improve security of wound closure. The authors compare absorbable barbed sutures (V-Loc, Covidien, Mansfield, Massachusetts) with conventional (smooth) absorbable sutures for soft tissue approximation. A prospective multicenter randomized study comparing barbed sutures with smooth sutures was undertaken between August 13, 2009, and January 31, 2010, in 241 patients undergoing abdominoplasty, mastopexy, and reduction mammaplasty. Each patient received barbed sutures on 1 side of the body, with deep dermal sutures eliminated or reduced. Smooth sutures with deep dermal and subcuticular closure were used on the other side as a control. The primary endpoint was dermal closure time. Safety was assessed through adverse event reporting through a 12-week follow-up. A total of 229 patients were ultimately treated (115 with slow-absorbing polymer and 114 with rapid-absorbing polymer). Mean dermal closure time was significantly quicker with the barbed suture compared with the smooth suture (12.0 vs 19.2 minutes; P<.001), primarily due to the need for fewer deep dermal sutures. The rapid-absorbing barbed suture showed a complication profile equivalent to the smooth suture, while the slow-absorbing barbed suture had a higher incidence of minor suture extrusion. Barbed sutures enabled faster dermal closure quicker than smooth sutures, with a comparable complication profile. 1.

  6. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    Science.gov (United States)

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.

  7. Sutural expansion osteogenesis for management of the bony-tissue defect in cleft palate repair: experimental studies in dogs.

    Science.gov (United States)

    Liu, C; Song, R; Song, Y

    2000-05-01

    A series of experimental studies on sutural expansion osteogenesis for management of the bony-tissue defect in cleft palate repair was performed between 1995 and 1997. Forty-five young dogs in weaning were used in four experiments that were divided into two parts. Part I probed the possibility of closing the surgically constructed hard palate cleft not only with mucoperiosteum but also with bony tissue by the technique of sutural expansion of lateral palatine sutures. Part II explored the possibility of pushing the palatine bone posteriorly and advancing the maxillary segment anteriorly by transverse palatine suture expansion. In Part I, a ring-shaped suture expander made of nickel-titanium shape memory alloy was used to expand the lateral suture of palatine bones. Expansion forces of 200 G, 360 G, and 480 G were used for the first experiment. A force of 360 G was chosen for two other experiments; this force is equivalent to the distraction rate of 0.5 mm per day of a jackscrew device. The ring-shaped suture expander was opened and its two feet were fixed in the medial sides of residual horizontal plates of the palatine bones immediately after a hard palate cleft was constructed surgically under endotracheal general anesthesia. At the eighth postoperative day, under the traction of 360 G, the two sides of the 8-mm-wide hard palate cleft were brought into contact with each other, and 8 or 9 days later the closed palatal cleft had healed completely with mucosal tissue. This experiment was repeated twice and yielded the same results. Sutural expansion osteogenesis was evaluated physically, fluorescently, histologically, and ultrastructurally to examine the deposition of the regenerated bone in the suture areas. Additionally, the influence of sutural expansion osteogenesis of the palatal bones on other facial bones was also studied cephalometrically. In Part II, a bow-shaped suture expander made of nickel-titanium shape memory alloy was applied to expand either the

  8. Maintenance of the anterior chamber during penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1976-01-01

    A description of the author's (S.G.K.) technique for penetrating keratoplasty is provided. The salient features include corneal removal, storage, and corneal graft cutting procedures of Kaufman and his co-workers. In addition, a specially designed suturing contact lens is described which allows maintenance of the anterior chamber during penetrating keratoplasty. It is suggested that trauma to the all-important cornea endothelium can be minimized by application of this technique, because it significantly reduces the likelihood of endothelial trauma induced by mechanical contact of the endothelium with intraocular recipient structures during suturing.

  9. Application analysis on different suture of scleral flap in trabeculectomy

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2014-05-01

    Full Text Available AIM: To research the application of scleral flap suture in trabeculectomy. METHODS: Totally 114 primary angle-closure glaucoma patients, aged from 36-72 years old, were selected as the objects, and randomly divided into research group and control group. The two groups received different administration methods. Traditional sewing method of sclera flap was used in research group and improved sewing method of sclera flap was used in control group. RESULTS: There was statistical differences between postoperative intraocular pressure of the patients in the observation group and the control group after 1d; 2wk; 1, 3mo(PPP>0.05.CONCLUSION: It is safe and effective that the improved sewing method of sclera flap for trabeculectomy of acute angle-closure glaucoma, and it is a better method to avoid the occurrence of shallow anterior chamber than the traditional sewing method in the early stage after operation.

  10. Functional implications of squamosal suture size in paranthropus boisei.

    Science.gov (United States)

    Dzialo, Christine; Wood, Sarah A; Berthaume, Michael; Smith, Amanda; Dumont, Elizabeth R; Benazzi, Stefano; Weber, Gerhard W; Strait, David S; Grosse, Ian R

    2014-02-01

    It has been hypothesized that the extensively overlapping temporal and parietal bones of the squamosal sutures in Paranthropus boisei are adaptations for withstanding loads associated with feeding. Finite element analysis (FEA) was used to investigate the biomechanical effects of suture size (i.e., the area of overlap between the temporal and parietal bones) on stress, strain energy, and strain ratio in the squamosal sutures of Pan troglodytes and P. boisei (specimen OH 5) during biting. Finite element models (FEMs) of OH 5 and a P. troglodytes cranium were constructed from CT scans. These models contain sutures that approximate the actual suture sizes preserved in both crania. The FEM of Pan was then modified to create two additional FEMs with squamosal sutures that are 50% smaller and 25% larger than those in the original model. Comparisons among the models test the effect of suture size on the structural integrity of the squamosal suture as the temporal squama and parietal bone move relative to each other during simulated premolar biting. Results indicate that with increasing suture size there is a decreased risk of suture failure, and that maximum stress values in the OH 5 suture were favorable compared to values in the Pan model with the normal suture size. Strain ratios suggest that shear is an important strain regime in the squamosal suture. This study is consistent with the hypothesis that larger sutures help reduce the likelihood of suture failure under high biting loads. Copyright © 2013 Wiley Periodicals, Inc.

  11. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  12. Modified method for bronchial suture by Ramirez Gama compared to separate stitches suture: experimental study

    Directory of Open Access Journals (Sweden)

    Vitor Mayer de Moura

    Full Text Available OBJECTIVE: To experimentally compare two classic techniques described for manual suture of the bronchial stump. METHODS: We used organs of pigs, with isolated trachea and lungs, preserved by refrigeration. We dissected 30 bronchi, which were divided into three groups of ten bronchi each, of 3mm, 5mm, and 7mm, respectively. In each, we performed the suture with simple, separated, extramucosal stitches in five other bronchi, and the technique proposed by Ramirez and modified by Santos et al in the other five. Once the sutures were finished, the anastomoses were tested using compressed air ventilation, applying an endotracheal pressure of 20mmHg. RESULTS: the Ramirez Gama suture was more effective in the bronchi of 3, 5 and 7 mm, and there was no air leak even after subjecting them to a tracheal pressure of 20mmHg. The simple interrupted sutures were less effective, with extravasation in six of the 15 tested bronchi, especially in the angles of the sutures. These figures were not significant (p = 0.08. CONCLUSION: manual sutures of the bronchial stumps were more effective when the modified Ramirez Gama suture was used in the caliber bronchi arms when tested with increased endotracheal pressure.

  13. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  14. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  15. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  16. Arthroscopic double-row suture anchor fixation of minimally displaced greater tuberosity fractures.

    Science.gov (United States)

    Ji, Jong-Hun; Kim, Weon-Yoo; Ra, Ki-Hang

    2007-10-01

    In cases of displaced greater tuberosity fractures, treatments by arthroscopic-assisted reduction and percutaneous screw fixation have been reported. However, in cases in which there is a comminuted fracture or a minimally displaced fracture combined with concomitant lesions such as rotator cuff tear or labral pathology, it is difficult to reduce the fracture and to treat other pathologies by use of a percutaneous screw. Recently, many surgeons have used the double-row repair method in rotator cuff repair, which provides a tendon-bone interface better suited for biologic healing and restoring normal anatomy. In accordance with this method, we used the arthroscopic technique of double-row suture anchor fixation for a minimally displaced greater tuberosity fracture without additional incision. Initially, debridement was performed on the fracture surface by use of a shaver, and the medial-row anchor was inserted through the anterior portal or the intact cuff. Two lateral-row anchors were inserted just anterior and posterior to the lower margin of the fractured fragment under C-arm guidance. The medial-row sutures and lateral-row sutures were then placed. Arthroscopic double-row suture anchor fixation of a displaced greater tuberosity fracture restores the original footprint of the rotator cuff and normal tendon-bone interface of the displaced greater tuberosity fracture.

  17. Experimental study of the characteristics of a novel mesh suture.

    Science.gov (United States)

    Dumanian, G A; Tulaimat, A; Dumanian, Z P

    2015-09-01

    The failure of sutures to maintain tissue in apposition is well characterized in hernia repairs. A mesh suture designed to facilitate tissue integration into and around the filaments may improve tissue hold and decrease suture pull-through. In vitro, the sutures were compared for resistance to pull-through in ballistics gel. In vivo, closure of midline laparotomy incisions was done with both sutures in 11 female pigs. Tissue segments were subsequently subjected to mechanical and histological testing. The mesh suture had tensile characteristics nearly identical to those of 0-polypropylene suture. Mesh suture demonstrated greater resistance to pull-through than standard suture (mean(s.d.) 4.27(0.42) versus 2.23(0.48) N; P tension closures. A new mesh suture design with a flexible macroporous outer wall and a hollow core allows the tissues to grow into the suture, improving early wound strength and decreasing suture pull-through. This technology may dramatically increase the reliability of high-tension closures, thereby preventing incisional hernia after laparotomy. As suture pull-through is a problem relevant to all surgical disciplines, numerous additional indications are envisioned with mesh suture formulations of different physical properties and materials. © 2015 The Authors. BJS published by John Wiley & Sons Ltd on behalf of BJS Society Ltd.

  18. A randomized clinical trial of knotless barbed suture vs conventional suture for closure of the uterine incision at cesarean delivery.

    Science.gov (United States)

    Peleg, David; Ahmad, Ronan Said; Warsof, Steven L; Marcus-Braun, Naama; Sciaky-Tamir, Yael; Ben Shachar, Inbar

    2018-03-01

    Knotless barbed sutures are monofilament sutures with barbs cut into them. These sutures self-anchor, maintaining tissue approximation without the need for surgical knots. The hypothesis of this study was that knotless barbed suture could be used on the myometrium to close the hysterotomy at cesarean delivery. The objective was to compare uterine closure time, need for additional sutures, and blood loss between this and a conventional suture. This was a prospective, unblinded, randomized controlled trial conducted at the Ziv Medical Center, Zefat, Israel. The primary outcome was the length of time needed to close the uterine incision, which was measured from the start of the first suture on the uterus until obtaining uterine hemostasis. To minimize provider bias, women were randomized by sealed envelopes that were opened in the operating room just prior to uterine closure with either a bidirectional knotless barbed suture or conventional suture. Secondary outcomes included the number of additional hemostatic sutures needed and blood loss during incision closure. Patients were enrolled from August 2016 until March 2017. One hundred two women were randomized. Fifty-one had uterine closure with knotless barbed suture and 51 with conventional suture. The groups were similar for demographics as well as number of previous cesarean deliveries. Uterine closure time using the knotless barbed suture was significantly shorter than the conventional suture by a mean of 1 minute 43 seconds (P barbed sutures were associated with a lower need for hemostatic sutures (median 0 vs 1, P barbed suture is a reasonable alternative to conventional sutures because it reduced the closure time of the uterine incision. There was also less need for additional hemostatic sutures and slightly reduced estimated blood loss. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Evaluation of absorbable and nonabsorbable sutures for repair of achilles tendon rupture with a suture-guiding device.

    Science.gov (United States)

    Kocaoglu, Baris; Ulku, Tekin Kerem; Gereli, Arel; Karahan, Mustafa; Turkmen, Metin

    2015-06-01

    The purpose of this study was to compare the functional and clinical results of Achilles tendon repairs with an Achilles tendon suture-guiding device using nonabsorbable versus absorbable sutures. We hypothesized that the absorbable suture would have clinical results comparable to those of the nonabsorbable suture for Achilles tendon repair with an Achilles tendon suture-guiding system. From January 2010 to September 2013, 48 consecutive patients who had sustained a spontaneous rupture of the Achilles tendon underwent operative repair with an Achilles tendon suture-guiding device using 2 different suture types. All ruptures were acute. The patients were divided equally into 2 groups according to suture type. In the nonabsorbable suture group, No. 2 braided nonabsorbable polyethylene terephthalate sutures were used, and in the absorbable suture group, braided absorbable polyglactin sutures were used. The average age of the patients was 38 years (range, 28-50 years). Functional outcome scores and complications were evaluated. All patients had an intact Achilles repair after surgery. The American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot clinical outcome scores were 98 (range, 90-100) in the nonabsorbable suture group and 96.8 (range, 87-100) in the absorbable suture group. All patients returned to their previous work. The absorbable suture group had fewer postoperative complications (0%) than the nonabsorbable suture group (12.5%) (P guiding system was associated with a lower incidence of suture reaction; however, functionally the results were not notably different from those using a traditional nonabsorbable suture. We conclude that repair with absorbable sutures is appropriate for Achilles tendon ruptures. Level II, prospective comparative study. © The Author(s) 2015.

  20. Mechanical performance of gamma irradiated surgical sutures

    Energy Technology Data Exchange (ETDEWEB)

    Pino, Eddy S.; Rela, Paulo P. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2000-07-01

    Surgical sutures are medical devices made of natural or synthetic polymeric materials that, due to its end-use, have to be sterilized. Historically, the sterilization by heat or using ethylene oxide had presented so numerous drawbacks that today the non-pollutant radiation sterilization has become a well established sterilization process, that brings, environmental, technical, and economical advantages. The amount of irradiation doses required for sterilization of health care products is 25 kGy in most instances to achieve the necessary sterility assurance level. As high energy radiation produces modifications in the molecular structure of organic materials with changes in its mechanical properties, the aim of this work was to evaluate the mechanical behavior of surgical sutures under irradiation. Silk, polyamide and catgut sutures were gamma irradiated up to doses of 50 kGy in an industrial irradiation sterilization plant. Afterwards, these sutures were mechanical tested for tensile strength under knot following the specifications of the NBR13904 draft standard, using the CTRD-INSTRON at IPEN. The mechanical lab results show that sutures made of Silk and Polyamide do not present any change in their mechanical performance up to the dose of 50 kGy. On the other hand, Catgut present mechanical stability up to 30 kGy and afterwards, a slight decrease in its tensile strength was detected. (author)

  1. Celebrity arcade suture blepharoplasty for double eyelid.

    Science.gov (United States)

    Liao, Wen-Chieh; Tung, Tung-Chain; Tsai, Tzong-Ru; Wang, Chia-Yi; Lin, Chiu-Hwa

    2005-01-01

    In Taiwan, double-eyelid surgery is the most popular cosmetic surgical procedure. The technique preferred by plastic surgeons is the incision method because it is believed that this method can provide stable double-eyelid results. It is the authors' observation that patients prefer an invagination fold rather than a significantly high fold. Suture blepharoplasty may create a relatively even and symmetric invagination fold. In the past, the major disadvantage of the suture technique has been the opinion that the double fold fades away. The celebrity arcade suture (CAS) technique was applied in double-eyelid operations. The CAS technique includes three major techniques: stabbing incision, transtarsal suture, and bridge connection. The whole procedure can be completed in 15 min. From June 2001 to November 2004, 312 patients underwent the CAS technique. Of the 312 patients who underwent the CAS technique, 5 required a revisit, with 3 of these returning patients reporting fold disappearance. These three patients received repeat suture procedures. The findings show that the CAS technique is a reliable method for establishing a smooth, constant, and symmetric double eyelid, and that CAS requires only a short recovery time.

  2. Posterior Cruciate Ligament Injury

    Science.gov (United States)

    ... the thighbone (femur) to the shinbone (tibia). The anterior and posterior cruciate ligaments form an "X" in the center of the knee. Although a posterior cruciate ligament injury generally causes less pain, disability and knee instability than does an ACL ...

  3. [Predictable tip suture techniques in rhinoplasty].

    Science.gov (United States)

    Papel, I D

    2010-09-01

    Recontouring the nasal tip in rhinoplastic procedures has generated a wide range of surgical techniques. These range from aggressive cartilage resection, division, grafting, or suture methods. Each of these categories contains many variations described in hundreds of publications. The goal of this communication is to describe a predictable, reproducible technique that can be used in a wide variety of rhinoplasty operations. Based on pre-existing anatomy variations of this technique can be adopted. The author described the basic technique in 2004 [1].The cornerstone of the technique is a predictable method of narrowing the interdomal space utilizing a suture technique. This procedure employs a pair of permanent sutures designed to minimize distortion, valve impingement and overcorrection. It can be performed through intranasal or external approaches. This paper will define the wide interdomal space, describe the technique, and demonstrate the efficacy of the technique in 250 rhinoplasty procedures. In addition, variations of the technique for specific goals will be shown.

  4. Intracorporal suturing--driving license necessary?

    Science.gov (United States)

    Romero, P; Brands, O; Nickel, F; Müller, B; Günther, P; Holland-Cunz, S

    2014-07-01

    Intracorporeal suturing and knot tying (ICKT) in minimal invasive surgery (MIS) represents a key skill for advanced procedures. Different methods exist for measuring knot quality and performance, but the heterogeneity of these methods makes direct comparisons difficult. The aim of this study is to compare the quality of a laparoscopic knot to one that is performed open. To compare open and laparoscopic knot-tying methods we used a surgeon's square knot. For laparoscopic knot tying we used a Pelvitrainer. The 32 participants were divided among 4 groups of different skill levels. Group 1 consisted of 6 senior physicians. Group 2 was made up of 10 first to fourth year interns. Groups 3 and 4 contained 16 medical students who had never performed either laparoscopic procedures or open sutures before. Group 3 participants received a 1-hour hands-on training in suturing, whereas group 4 participants received no prior training. Total time, knot quality, suture placement accuracy, and performance defined the parameters for assessment in this study. All participants, irrespective of education level were inferior in ICKT compared to open suturing. Only Group 1 showed no significant difference in knot quality and accuracy between the open and laparoscopic suture performance. It is well documented that psychomotor skills need to be developed before more advanced skills can be put into practice. Training centres for minimally invasive surgery should be an integral part of surgical education. The variables in our study are meaningful and easy to implement. They can be used to measure personal progress and as objective parameters in the development of laparoscopic trainee education. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Achondroplasia with multiple-suture craniosynostosis: a report of a new case of this rare association.

    Science.gov (United States)

    Bessenyei, Beáta; Nagy, Andrea; Balogh, Erzsébet; Novák, László; Bognár, László; Knegt, Alida C; Oláh, Eva

    2013-10-01

    We report on a female patient with an exceedingly rare combination of achondroplasia and multiple-suture craniosynostosis. Besides the specific features of achondroplasia, synostosis of the metopic, coronal, lambdoid, and squamosal sutures was found. Series of neurosurgical interventions were carried out, principally for acrocephaly and posterior plagiocephaly. The most common achondroplasia mutation, a p.Gly380Arg in the fibroblast growth factor receptor 3 (FGFR3) gene, was detected. Cytogenetic and array CGH analyses, as well as molecular genetic testing of FGFR1, 2, 3 and TWIST1 genes failed to identify any additional genetic alteration. It is suggested that this unusual phenotype is a result of variable expressivity of the common achondroplasia mutation. Copyright © 2013 Wiley Periodicals, Inc.

  6. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Science.gov (United States)

    2010-04-01

    ... polyamide surgical suture. (a) Identification. Nonabsorbable polyamide surgical suture is a nonabsorbable, sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and is...

  7. 21 CFR 878.4930 - Suture retention device.

    Science.gov (United States)

    2010-04-01

    ... button, or a suture bolster, intended to aid wound healing by distributing suture tension over a larger area in the patient. (b) Classification. Class I (general controls). The device is exempt from the...

  8. Comparison of suture types in the closure of scalp wounds.

    LENUS (Irish Health Repository)

    Bonham, Joseph

    2011-06-01

    Innovation in practice can benefit patients and healthcare providers but must be evidence based. This article describes a quantitative study of whether absorbable sutures are as beneficial as non-absorbable sutures in the management of simple scalp lacerations in adults. The results suggest that absorbable sutures can provide the same cosmetic and functional results as non-absorbable sutures. Their use can also reduce patient returns and save money and resources.

  9. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  10. Cranial suture complexity in white-tailed deer (Odocoileus virginianus).

    Science.gov (United States)

    Nicolay, Christopher W; Vaders, Mark J

    2006-07-01

    Neurocranial expansion and mastication are commonly implicated as the two major biomechanical factors affecting suture morphology. In deer the antlers provide an additional source of biomechanical stress acting on the skull. Equivalent stresses are not found in females, who lack antlers. We analyzed the complexity and interdigitation of the interfrontal and coronal sutures that surround the antler-bearing frontal bones of (n = 67) white-tailed deer (Odocoileus virginianus) to 1) evaluate changes in suture morphology throughout ontogeny, and 2) test the hypothesis that male deer have more complex sutures than females. Two methods were used to quantify suture morphology: fractal analysis and length-ratios (actual suture length divided by direct straightline length). Both techniques produced similar results, although the two methods cannot be considered equivalent. Suture complexity increases markedly throughout ontogeny, but appears to level off after animals have reached adulthood. Cranial size in males, but not females, continues to increase in adults. No significant increase in suture complexity with age in the adult cohort was detected. While deer are highly dimorphic in size and the presence of antlers, no significant differences existed between males and females for any measure of suture complexity. No consistent patterns emerged between suture complexity and skull size or antler characteristics. The presence of antlers appears to have a minimal effect on suture complexity in white-tailed deer. Factors that may contribute to the lack of dimorphism in suture complexity are discussed. (c) 2006 Wiley-Liss, Inc.

  11. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polypropylene surgical suture. 878... Nonabsorbable polypropylene surgical suture. (a) Identification. Nonabsorbable polypropylene surgical suture is... known as polypropylene and is indicated for use in soft tissue approximation. The polypropylene surgical...

  12. Three-Dimensional Analysis of Fibular Motion After Fixation of Syndesmotic Injuries With a Screw or Suture-Button Construct.

    Science.gov (United States)

    LaMothe, Jeremy M; Baxter, Josh R; Murphy, Conor; Gilbert, Susannah; DeSandis, Bridget; Drakos, Mark C

    2016-12-01

    observed in the intact specimen when subjected to an external rotation stress test and allowed significantly more posterior motion of the fibula than when fixed with a screw in simulated highly unstable injuries. Fixation of a syndesmotic injury with a single suture-button construct did not restore physiological fibular motion, which may have implications for postoperative care and clinical outcomes. © The Author(s) 2016.

  13. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

    Science.gov (United States)

    Lyu, J; Zhao, P-Q

    2016-05-01

    PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.

  14. Thyroid hormone action on rat calvarial sutures.

    Science.gov (United States)

    Akita, S; Nakamura, T; Hirano, A; Fujii, T; Yamashita, S

    1994-01-01

    To clarify the effect of thyroid hormone on the calvarial sutures, the morphology, histology, and bone mineral density were analyzed in thyroid hormone-injected rats. A total of 80 female Wistar rats at the age of 10 days were divided into 2 groups; the triiodothyronine (T3)-treated rats (n = 40, T3 100 micrograms/kg body weight/day) were maintained under the same conditions as controls (n = 40, saline-vehicle only), and both were sacrificed at 50, 80, and 200 experimental days, respectively. T3-treated animals showed smaller values of lambda-asterion and pterion-bregma distances at the various periods of examination, resulting in smaller sizes in right-left direction of the skull. The sagittal suture distance in the skull specimens observed by Goldner's staining (fibrous tissue content) appeared smaller and the osseous margin widths greatly increased in the T3-treated rats. Fluorescent microscopy revealed that the tetracycline-calcein double labelings were not interrupted from the periosteal to the endosteal areas in any specimens indicating the scantiness of osteoclastic activity in the suture areas. Mineral apposition rates at the osseous edges of the suture were significantly increased in the T3-treated rats (p < 0.01 at the age of 90 days). The distance between the second labels and the distance between the first labels were significantly larger in the T3-treated rats. Bone mineral density (BMD) measurement showed that the T3 administration decreased only the calvarial BMD at the age of 210 days (p < 0.01), but did not decrease lumbar or femur BMD. This experiment demonstrated clear evidence of excess thyroid hormone action on the early narrowing of the sagittal suture in infantile hyperthyroid rats, probably due to the enhanced osteogenic activity caused by the hormone.

  15. [A pancreas suture-less type II binding pancreaticogastrostomy].

    Science.gov (United States)

    Peng, Shu-you; Hong, De-fei; Liu, Ying-bin; Li, Jiang-tao; Tao, Feng; Tan, Zhi-jian

    2009-12-01

    To explore the feasibility and safety of type II binding pancreaticogastrostomy (BPG) in pancreaticoduodenectomy and mid-segmentectomy of pancreas. From November 2008 to May 2009, 26 patients underwent pancreaticoduodenectomy and mid-segmentectomy of pancreas with type II BPG reconstruction, including 13 cases of pancreatic head cancer, 3 cases of duodenal adenocarcinoma, 2 cases of ampullary carcinoma, 4 cases of cholangiocarcinoma, 1 case of bile duct cell severe atypical hyperplasia, and 1 case of stomach cancer. The process of type II BPG was described as the following: after pancreas remnant was mobilized for 2-3 cm, a piece of sero-muscular layer at the posterior gastric wall was excised and then a sero-muscular depth purse-suturing with 3-0 prolene was pre-placed (outer purse-string). Incising anterior gastric wall or opening part of the closed distal gastric stump, the mucosa layer at the sero-muscular defect was incised and then purse-suture at the mucosal tube was pre-placed (inner purse-string). Through the two pre-placed purse-strings, the pancreas remnant was pulled into the gastric lumen and then posterior gastric wall was pushed backward to keep it closely in contact with the retro-peritoneal wall. Thereafter, the outer purse-string was tied (outer binding) and then the inner purse-string was tied (inner binding). All cases underwent BPG of type II. The operative time ranged from 3 to 5.5 hours. The postoperative hospital stay ranged from 6 to 48 days. Postoperative complications included 1 case of ascites, 2 cases of delayed gastric emptying and 1 case of intra-abdominal bleeding. All cases with complications were cured after nonsurgical treatment. No mortality or pancreatic leakage occurred. Pancreaticogastrostomy is good for accommodating a large pancreas stump. Binding technique is very helpful in minimizing the leak rate of pancreaticogastrostomy. While type I BPG is safe and easy to perform, type II is even safer and easier to be done.

  16. Septal anchoring suture: a key suture to improve the nasolabial symmetry in unilateral cheiloplasty.

    Science.gov (United States)

    Lu, T-C; Filson, S; Yao, C-F; Chen, P K-T

    2018-04-03

    Since 2008, a septal anchoring suture has been used in unilateral cleft lip repair at Chang Gung Memorial Hospital in order to stabilize the lateral lip centrally. This study compared the symmetry of two groups of patients: those treated with and without an anchoring suture. Multiple standardized direct and photographic facial measurements were performed on the faces of all patients pre-cheiloplasty and at 5 years post-cheiloplasty. The degree of nasolabial symmetry was evaluated by comparing the ratios of measurements of the cleft vs. non-cleft sides. The ratio of change in these measurements was also compared postoperatively. The vertical lip length ratio approached 1 in the septal anchoring suture group, which differed significantly from the group without the suture (0.968 vs. 0.873, P<0.001). As expected, the horizontal lip length and central lip height ratios showed no statistically significant change. The ratio of change from pre- to postoperative also showed a significant improvement (P=0.028) in the vertical lip length of the group with the septal anchoring suture compared to the one without. The septal anchoring suture is a useful method to correct the tendency of the lip to shift to the cleft side. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Posterior muscolofascial reconstruction incorporated into urethrovescical anastomosis during robot-assisted radical prostatectomy.

    Science.gov (United States)

    Ficarra, Vincenzo; Gan, Melanie; Borghesi, Marco; Zattoni, Fabio; Mottrie, Alexandre

    2012-12-01

    The rationale of posterior musculofascial plate reconstruction during radical prostatectomy is to shorten the time to reach urinary continence recovery and to reduce the risk of bleeding and anastomosis leakage. We describe our original technique incorporating the posterior muscolofascial reconstruction into urethrovesical anastomosis using robot-assisted radical prostatectomy (RARP). For this reconstructive step, we use a 30-cm V-Loc 90 3-0 barbed suture (V-20 tapered needle). Specifically, the free edge of the posterior layer of the Denonvilliers fascia is approximated to the posterior part of the sphincteric apparatus in a running fashion from left to right. The musculature of the urethral wall is incorporated in this first layer of the running suture. This suture is then continued back to the left in a second layer incorporating the anterior layer of the Denonvilliers fascia (or prostatovesical muscle), the bladder neck, and again the urethra, this time also with urethral mucosa. The urethrovesical anastomosis is completed using a second running barbed suture (15-cm V-Loc 90 3-0 barbed suture, V-20 tapered needle). No intraoperative complications were observed during this step of the procedure. Anastomotic leakages were observed only in 2% of cases. Only 12.5% showed urinary incontinence after catheter removal (1-2 pads). At mean follow-up of 9 months, the urinary continence recovery was 95%, and an anastomosis stricture necessitating an endoscopic incision developed in only three (1.5%) patients. Recent systematic reviews of the literature showed only a minimal advantage in favor of posterior musculofascial reconstruction in terms of urinary continence recovery within 1 month after radical prostatectomy. We support the use of this step of RARP because it is simple, reproducible, with a very limited increase in operative time, and with only a slight risk of potential harm to the patient. Moreover, it could improve hemostasis and provide greater support for a

  18. Comparison of barbed unidirectional suture with figure-of-eight standard sutures in vaginal cuff closure in total laparoscopic hysterectomy.

    Science.gov (United States)

    Karacan, Tolga; Ozyurek, Eser; Usta, Taner; Odacilar, Eylem; Hanli, Ulviye; Kovalak, Ebru; Dayan, Huseyin

    2018-03-24

    The aim of the study was to compare postoperative vaginal cuff complications due to the use of barbed sutures (V-Loc™ 180 unidirectional suture; Covidien, Mansfield, MA) and standard braided sutures (Vicryl ® ; Ethicon Inc., Somerville, MA) during vaginal cuff closure of patients undergoing a total laparoscopic hysterectomy (TLH) due to benign diseases. Eighty-nine patients were in the standard suture group and 208 patients were included in the barbed suture group. Vaginal cuff dehiscence was identified in only three (3.3%) patients within the standard suture group and none in the barbed suture group. Five (5.6%) patients in the standard suture group and two (0.9%) patients in the barbed suture group developed postoperative cuff infection/cellulitis. Duration of the surgery was significantly shorter in the barbed suture group than in the standard suture group (p barbed suture, which is used during TLH for vaginal cuff closure, is an applicable, safe and tolerable alternative to a standard suture. IMPACT STATEMENT What is already known on this subject: Barbed sutures are a relatively new type of suture that include sharp barbs inserted on monofilament material in various configurations, and are used for approximating tissues without any need for surgical knotting. They have increasingly been used in obstetrics and gynaecology in recent years, particularly in total laparoscopic hysterectomy and laparoscopic myomectomy. At present, there are a limited number of studies of V-Loc™ suture in the literature. What the results of this study add: We demonstrated that barbed sutures used for enabling vaginal cuff integrity did not cause major morbidity and mortality for the patient. We suggest that V-Loc™ 180 barbed sutures offer a practical, safe and tolerable alternative for surgeons because they are easy to use, do not cause a significant increase in vaginal cuff complications, and shorten the operating time. Our study with V-Loc™ 180 unidirectional barbed

  19. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  20. Posterior labrocapsular periosteal sleeve avulsion complicating locked posterior shoulder dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Simons, P. [Department of Radiology, Onze Lieve Vrouwe Hospital, Aalst (Belgium)]|[Department of Radiology, Leiden University Medical Centre, Leiden (Netherlands); Joekes, E.; Bloem, J.L. [Department of Radiology, Leiden University Medical Centre, Leiden (Netherlands); Nelissen, R.G.H.H. [Department of Orthopaedic Surgery, Leiden University Medical Centre (Netherlands)

    1998-10-01

    This case presents the imaging features of a posterior shoulder dislocation complicated by a rare but surgically relevant lesion of the posterior labrum. Due to the attachment of the posterior capsule to the posterior portion of the labrum, which in itself is attached to the posterior scapular periosteum, stripping of the labrum by the posterior capsule resulted in a posterior labrocapsular periosteal sleeve avulsion. (orig.) With 4 figs., 5 refs.

  1. Biomechanical Dynamics of Cranial Sutures during Simulated Impulsive Loading

    Directory of Open Access Journals (Sweden)

    Z. Q. Zhang

    2015-01-01

    Full Text Available Background. Cranial sutures are deformable joints between the bones of the skull, bridged by collagen fibres. They function to hold the bones of the skull together while allowing for mechanical stress transmission and deformation. Objective. The aim of this study is to investigate how cranial suture morphology, suture material property, and the arrangement of sutural collagen fibres influence the dynamic responses of the suture and surrounding bone under impulsive loads. Methods. An idealized bone-suture-bone complex was analyzed using a two-dimensional finite element model. A uniform impulsive loading was applied to the complex. Outcome variables of von Mises stress and strain energy were evaluated to characterize the sutures’ biomechanical behavior. Results. Parametric studies revealed that the suture strain energy and the patterns of Mises stress in both the suture and surrounding bone were strongly dependent on the suture morphologies. Conclusions. It was concluded that the higher order hierarchical suture morphology, lower suture elastic modulus, and the better collagen fiber orientation must benefit the stress attenuation and energy absorption.

  2. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  3. Cost analysis of stapling versus suturing for skin closure.

    Science.gov (United States)

    Orlinsky, M; Goldberg, R M; Chan, L; Puertos, A; Slajer, H L

    1995-01-01

    A randomized, prospective study was performed to test the null hypothesis that there is no difference between the cost of stapling and suturing for skin closure of selected linear lacerations. Appropriate wounds were randomly assigned to be closed by staples or sutures. Wound lengths, skin closure times, and the number of staples or the number and types of sutures used were recorded. Costs for materials and labor were calculated. The average total cost per case was $17.69 (with suture kit) and $7.84 (without suture kit) for the staple Group compared with $21.58 for the suture Group (P = .0001 for each). It is concluded that stapling is less costly than suturing and that the advantage appears to increase as laceration length increases.

  4. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    haemorrhage >1000 ml, Diabetes, mental disorders. Both suture techniques were 2-layered using a polyglactin 910 multifilament suture (Vicryl Rapid or Vicryl). Treatment A was a continuous suture technique and treatment B was interrupted, inverted stitches. Primary outcomes: Perineal pain and wound healing......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time......-efficient suture technique which needed systematic evaluation. Objective To compare two standardized suture techniques for perineal repair of 2nd degree perineal lacerations or episiotomies. Design and setting A double-blind randomised clinical trial conducted in Aarhus University Hospital, Denmark. Initiated...

  5. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  6. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Devi, Dipali [Seri biotech laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Kalita, Dhaneswar [Government Ayurvedic College and Hospital, Jalukbari, Guwahati, Assam 781014 (India); Kalita, Kasturi [Department of Pathology, Hayat Hospital, Guwahati, Assam 781034 (India); Dash, Suvakanta [Girijananda Chowdhury Institute of pharmaceutical science, Azara, Guwahati, Assam 781017 (India); Kotoky, Jibon, E-mail: jkotoky@gmail.com [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India)

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  7. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    International Nuclear Information System (INIS)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-01-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  8. Tibial avulsion fracture of the posterior root of the medial meniscus in children

    DEFF Research Database (Denmark)

    Iversen, Jonas Vestergård; Krogsgaard, Michael Rindom

    2012-01-01

    Few reports have described avulsion fractures of the posterior root of the medial meniscus in skeletally immature patients. This lesion should not be overlooked as it damages the load absorptive (distributive) function of the meniscus, increasing the risk of cartilage degeneration. Two cases...... of displaced avulsion fractures of the posterior root of the medial meniscus in children are presented along with a concise report of the literature regarding avulsion fractures of the posterior root of the medial meniscus. Both avulsions were reattached arthroscopically by trans-tibial pull-out sutures...

  9. Achondroplasia and multiple-suture craniosynostosis.

    Science.gov (United States)

    Albino, Frank P; Wood, Benjamin C; Oluigbo, Chima O; Lee, Angela C; Oh, Albert K; Rogers, Gary F

    2015-01-01

    Genetic mutations in the fibroblast growth factor receptor 3 gene may lead to achondroplasia or syndromic forms of craniosynostosis. Despite sharing a common genetic basis, craniosynostosis has rarely been described in cases of confirmed achondroplasia. We report an infant with achondroplasia who developed progressive multiple-suture craniosynostosis to discuss the genetic link between these clinical entities and to describe the technical challenges associated with the operative management.

  10. Skin tension related to tension reduction sutures.

    Science.gov (United States)

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures.

  11. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  12. Posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Kushner, M.J.; Luken, M.G. III

    1983-01-01

    CT demonstrated posterior fossa epidural hematoma in three patients with head trauma in whom this diagnosis was not clinically apparent. No patient was in stupor or coma and no patient experienced a lucid interval. Only one patient had signs referable to the posterior fossa. Two patients had occipital skull fracture disclosed by plain radiographs. CT revealed a unilateral biconvex hematoma in two cases, and a bilateral hematoma with supratentorial extension in the third. All patients underwent suboccipital craniectomy and recovered. Therapeutic success in these cases was facilitated by early CT and the rapid disclosure of the unsuspected posterior fossa lesions. CT showing contiguous hematoma below and above the tentorium cerebelli after posterior head trauma is highly suggestive of epidural hematoma arising from the posterior fossa. (orig.)

  13. Blepharoptosis correction with buried suture method.

    Science.gov (United States)

    Park, Jang Woo; Kang, Moon Seok; Nam, Seung Min; Kim, Yong Bae

    2015-02-01

    Many surgical techniques have been developed to correct blepharoptosis, including the anterior levator resection or advancement, tarsoaponeurectomy, and Fasanella-Servat Müllerectomy. However, to minimize surgical scarring and reduce the postoperative recovery time, the procedure has been developed from a complete incision to a partial incision, which is appealing to patients. To aid the procedural development, this study describes a surgical technique in which the correction of blepharoptosis and a double eyelid fold operation are performed using a buried suture technique during the same operation. A retrospective review was conducted using the medical records and preoperative and postoperative photography of 121 patients who underwent simultaneous correction of blepharoptosis and had a double eyelid fold created between October 2010 and July 2011. All of the patients had mild (1-2 mm) or moderate (3-4 mm) bilateral blepharoptosis and excellent or good levator function (>8 mm). The average preoperative marginal reflex distance (MRD1) measured 1.174 (0.3) mm. No intraoperative complications occurred. The average postoperative MRD1 measured 3.968 (0.2) mm. There was statistical significance improvement between preoperative MRD1 and postoperative MRD1 (P<0.05). No symptomatic dry eye and exposure keratopathy were noted. Blepharoptosis correction using the buried suture technique is an effective technique for young patients experiencing mild to moderate blepharoptosis who want to have the double eyelid fold operation using the buried suture technique.

  14. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial.

    Science.gov (United States)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  15. Bidirectional Barbed Sutures for Wound Closure: Evolution and Applications

    Science.gov (United States)

    Paul, Malcolm D.

    2009-01-01

    Traditionally, wound closure sutures have in common the need to tie knots with the inherent risk of extrusion, palpability, microinfarcts, breakage, and slippage. Bidirectional barbed sutures have barbs arrayed in a helical fashion in opposing directions on either side of an unbarbed midsegment. This suture is inserted at the midpoint of a wound and pulled through till resistance is encountered from the opposing barbs; each half of the suture is then advanced to the lateral ends of the wound. This design provides a method of evenly distributing tension along the incision line, a faster suture placement and closure time with no need to tie knots, and the possibility of improved cosmesis. Bidirectional barbed sutures, which are available in both absorbable and nonabsorbable forms, can be used for simple closures, multilayered closures, and closure of high-tension wounds in a variety of surgical settings. PMID:24527114

  16. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  17. Automatic Detection of Wild-type Mouse Cranial Sutures

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Darvann, Tron Andre; Hermann, Nuno V.

    , automatic detection of the cranial sutures becomes important. We have previously built a craniofacial, wild-type mouse atlas from a set of 10 Micro CT scans using a B-spline-based nonrigid registration method by Rueckert et al. Subsequently, all volumes were registered nonrigidly to the atlas. Using...... these transformations, any annotation on the atlas can automatically be transformed back to all cases. For this study, two rounds of tracing seven of the cranial sutures, were performed on the atlas by one observer. The average of the two rounds was automatically propagated to all the cases. For validation......, the observer traced the sutures on each of the mouse volumes as well. The observer outperforms the automatic approach by approximately 0.1 mm. All mice have similar errors while the suture error plots reveal that suture 1 and 2 are cumbersome, both for the observer and the automatic approach. These sutures can...

  18. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  19. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  20. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  1. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  2. Refrigeration Test Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The enclosed and environmentally controlled chamber is able to test four units (single-phase) simultaneously at conditions ranging from tundra to desert temperatures...

  3. Role of the osteoclast in cranial suture waveform patterning.

    Science.gov (United States)

    Byron, Craig Daniel

    2006-05-01

    This study investigates the role of bone resorption in defining interdigitations characteristic of cranial suture waveform. Male mice from the CD-1 (ICR) background were analyzed at six age groups (n = 5 mice per group) in order to study the ontogenetic changes of osteoclast counts using tartrate-resistant acid phosphatase-stained histological sections of sagittal sutures. Additionally, the complexity of suture lines were measured ectocranially from the same age groups (n = 5 per group) using image capture and fractal geometry (ruler dimension method). The results suggest that osteoclast resorption is a contributor to suture patterning. Specifically, osteoclasts show the greatest activity along concave suture regions at 42 and 84 days (Kruskal-Wallis test statistic = 14.9; P weaning and the transition to a hard chow diet. These data demonstrate osteoclasts along the bone margin of the cranial suture and also indicate that sutures attain their complex shape at the same age when osteoclast number is highest along concave suture margins, underscoring the role of osteoclasts in generating the suture waveform pattern. 2006 Wiley-Liss, Inc.

  4. Sutural simplification in Physodoceratinae (Aspidoceratidae, Ammonitina

    Directory of Open Access Journals (Sweden)

    Checa, A.

    1987-08-01

    Full Text Available The estructural analysis of the shell septum interrelationship in sorne Jurassic ammonites allows us to conclude that sutural simplifications occurred throughout the phylogeny, were originated by alterations in the external morphology of the shell. In the case of Physodoceratinae the simplification observed in the morphology of the septal suture may have a double origin. First, an increase in the size of periumbilical tubercles may determine a shallowing of sutural elements and a shortening of saddle and lobe frilling. In other cases, shallowing is determined by a decrease in the whorl expansion rate, an apparent shortening of secondary branching not being observed.El análisis estructural de la interrelación concha-septo en algunos ammonites del Jurásico superior lleva a concluir que las simplificaciones suturales aparecidas a lo largo de la filogenia fueron originadas por alteraciones ocurridas en la morfología externa de la concha. En el caso concreto de la subfamilia Physodoceratinae, la simplificación observada en la morfología de la sutura puede tener un doble origen. En primer lugar, un incremento en el tamaño de los tubérculos periumbilicales puede determinar una pérdida de profundidad de los elementos de la sutura. siempre acompañada de una disminución en las indentaciones (frilling de sillas y lóbulos. En otros casos el acortamiento en profundidad está determinado por una disminución de la tasa de expansión de la espira, sin que se observe un acortamiento aparente de las ramificaciones secundarias.

  5. A Modified Fisherman's Knot for Laparoscopic Suturing.

    Science.gov (United States)

    Meylemans, Diederik; Handojo, Karen; Devroe, Kurt; Aelvoet, Chris; Vermeiren, Koen; Tollens, Tim

    2016-04-01

    Suturing is an essential surgical technique, because there is no resection without the need for reconstruction. Therefore, every surgeon should master a set of suturing techniques so he can adapt his approach to the specificity of the situation. The development of laparoscopic surgery poses a new challenge as not all open techniques are amendable for laparoscopic use. We would like to propose a modified fisherman's knot, which has been optimised in our center for laparoscopic use. The technique can be used with every monofilament non-braided wire. The needle is placed through the tissue to be sutured and both wires are externalised through the trocar. First, a simple knot is placed by crossing the left over the right wire. Next, the left is turned around the right wire four times proximal to the starting knot and crossed to the left wire where an additional two turns are made moving away from the trocar. The knot is closed gently, making sure not to lock the knot. Then the instrument of Drouard is used to gently glide the knot over the right wire back through the trocar into the abdomen. After making sure that adequate pressure has been delivered to the knot, to firmly close the tissue, the wire must be cut at a length of at least 3 mm. A new wire should be used for every knot and in this manner several knots can be delivered to make sure the tissue is adequately closed. In our center, no known complications due to loosening or failure of these knots have occurred since we incorporated this knotting technique into our daily practice more than 20 years ago.

  6. Bone suture and lateral sinus lift surgery

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2015-01-01

    Full Text Available Bone suture in lateral sinus lift has four indications. Three of them depend on creating a hole in the lateral maxillary sinus wall above the antrostomy window for securing the elevated medial maxillary sinus membrane to manage perforated Schneiderian membrane. Covering the buccal antrostomy window with the buccal fat pad (BFP for better nourishment of the inserted graft and as an alternative for bone tags in fixation of collagen membrane has been reported previously. A new indication for firmly anchoring the BFP to the medial maxillary sinus wall as the last resort for the management of perforated Schneiderian membrane is explained in this article.

  7. Evolution of Complexity in Paleozoic Ammonoid Sutures.

    Science.gov (United States)

    Saunders; Work; Nikolaeva

    1999-10-22

    The septal sutures of 588 genera of Paleozoic ammonoids showed a 1600 percent increase in mean complexity over 140 million years. Within 475 ancestor/descendant pairs, descendants were more than twice as likely to be more complex than their ancestors. Twelve subclades (373 genera) averaged 34 percent increased complexity. These patterns are compatible with an active or driven system of long-term bias for increased complexity. Mass extinctions acted in opposition to this long-term trend, tending to eliminate more-complex forms and resetting the trend with each extinction event.

  8. Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius H. de Carvalho

    Full Text Available Abstract Introduction: Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective: To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods: 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results: In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002. In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002. Intraluminal adhesive penetration has not been noticed. Conclusion: There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries.

  9. Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.; Eppard, M. B.; Cooke, Steven J.

    2013-10-01

    Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

  10. COMPARISON OF ABSORBABLE EXTRA LONG TERM POLY HYDROXY BUTYRATE SUTURE VS NON ABSORBABLE (POLYPROPYLENE SUTURE FOR ABDOMINAL WALL CLOSURE

    Directory of Open Access Journals (Sweden)

    Mallikarjun

    2015-07-01

    Full Text Available PURPOSE: The aim of study is to compare Continuous technique with non - absorbable sutures, Interrupted technique with non - absorbable sutures and Continuous technique with slowly absorbable sutures Focusing mainly on incidence of incisional hernias, burst abdomen, wound infections, chronic wound pain, suture sinus, stitch granuloma, time for rectus closure. METHODOLOGY : Study was conducted for a period of one year on 271 randomized patients with primary elective midline laparotomy in our hospital . patients are divided into group I includes 102 patients with continuous technique using non absorbable polypropylene, group II includes 91 patients with interrupted technique using non absorbable polypropylene and group III includes 78 patients with continuous slowly absorbable polyhydroxybutyrate. RESULTS: No significant difference observed in incidence of wound infections and burst abdomen in all the 3 groups but relatively higher incidence of wound infections in noted our hospital. Incidence of stich granuloma suture sinus and chronic wound pain is more with interrupted technique than continuous technique and are more with non - absor bable suture material. CONCLUSION: Incidence of incisional hernias, suture complications like suture sinus, stitch granuloma can be more effectively reduced with slowly absorbable continuous sutures.

  11. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  12. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  13. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  14. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  15. DELPHI time projection chamber

    CERN Document Server

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  16. Tensile strength and failure load of sutures for robotic surgery.

    Science.gov (United States)

    Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P

    2017-08-01

    Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety

  17. Geophysical exploration of the Kalahari Suture Zone

    Science.gov (United States)

    Brett, J. S.; Mason, R.; Smith, P. H.

    2000-04-01

    Fancamp Resources Limited of Montreal, Canada, commenced exploration of the Kalahari Suture Zone in southwest Botswana in 1996, following the interpretation of airborne magnetic surveys covering 400 km of strike along the Kalahari Suture Zone. Initial focus was on mafic/ultramafic intrusions associated with the Tshane Complex as potential targets for CuNiPGM mineralization, but these targets are now considered to be too deeply buried (> 700 m) to be of economic significance at this time. The exploration focus has been redirected to several prospective large coincident magnetic/gravity anomalies. These are considered prospective targets for Olympic Dam-type CuCo mineralisation associated with alkaline intrusive complexes, and/or NiCuCoPGM mineralisation associated with basic intrusive complexes. The two most important and prospective targets are the so-called 'Great Red Spot' and Tsetseng Complex. Additional ground geophysical surveys and deep drilling are planned for the next phase of exploration. These large targets are of high priority and represent tremendous potential for mineral development in the sparsely populated area of western Botswana.

  18. The malament suture: any role in transvesical prostatectomy ...

    African Journals Online (AJOL)

    Conclusion: From our study, the Malament suture does not increase the incidence of bladder neck stenosis; neither does it reduce the need for blood transfusion. Prospective studies are required to further investigate these and find out if the Malament suture reduces the volume of fluid required for irrigation or the need to ...

  19. Mechanical model of suture joints with fibrous connective layer

    Science.gov (United States)

    Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning

    2018-02-01

    A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.

  20. Punctal occlusion with Prolene suture material in the patients with ...

    African Journals Online (AJOL)

    Aim: To analyze the efficacy and outcomes of punctal occlusion with 5-0 Prolene suture material for the treatment of dry eye. Materials and. Methods: A total of 20 patients with moderate and severe dry eyes, recalcitrant to maximal medical therapy, underwent temporary punctal occlusion with 5-0 Prolene suture material.

  1. Suture associated corneal abscess three years after cataract surgery ...

    African Journals Online (AJOL)

    The abscess was carefully removed on slit lamp using blunt tipped forceps without breaking the thin membrane covering it. There was a deep corneal depression at the bottom of which was found a loose 10/0 nylon corneoscleral suture. Another loose suture was present at the 12 o'clock position surrounded by stromal ...

  2. Spondylolisthesis and Posterior Instability

    International Nuclear Information System (INIS)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D.; Simons, P.; Kuchta, J.

    2009-01-01

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI

  3. Spondylolisthesis and Posterior Instability

    Energy Technology Data Exchange (ETDEWEB)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D. (Privatpraxis fuer Upright MRT, Koeln (Germany)); Simons, P.; Kuchta, J. (Media Park Klinik, Koeln (Germany))

    2009-04-15

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI.

  4. Posterior Elbow Dislocation

    Directory of Open Access Journals (Sweden)

    Victoria Oppenheim

    2016-09-01

    Full Text Available History of present illness: A 15-year old female presented with left elbow pain. While competing in a high school wrestling match, she extended her left arm to brace a fall and had immediate onset of sharp pain. She denied weakness or numbness of her left arm. She had no past medical history. Significant findings: Elbow dislocations are classified by the position of the radio-ulnar joint relative to the humerus.1 Images 1, 2, and 3 show a left posterior elbow dislocation; the radius and ulna are displaced posteriorly with respect to the distal humerus. The lateral view of the elbow most clearly shows this: trochlear notch of the ulna is empty and displaced posteriorly relative to the trochlea. There is no associated fracture. Images 4 and 5 show the elbow status-post reduction, demonstrating proper alignment of the distal humerus with the radius and ulna. Discussion: Traumatic dislocations of the elbow are relatively uncommon in pediatric patients, with a peak incidence at 13 to 14 years.1 Dislocations are usually posterior and occur after forced abduction and extension of the elbow.1 It is important to evaluate for an associated fracture or avulsion, which occurs in over 50% of pediatric elbow dislocations. Fractures most commonly involve the medial epicondyle, radial head and neck, or coronoid process.1 One should also consider a neurovascular injury to the ulnar or median nerve or to the brachial artery or its branches.1 Posterior elbow dislocations should be reduced as soon as possible.1 Patients should receive adequate sedation and/or analgesia. One method of reduction is the “puller” technique, during which a practitioner stabilizes the humerus, while a second practitioner applies force against the anterior forearm, with gentle traction distally.1 Post-reduction neurovascular reassessment is important. After successful reduction, patients can be immobilized in a posterior long arm splint.

  5. Posterior tracheal diverticulosis.

    Science.gov (United States)

    Madan, Karan; Das, Chandan J; Guleria, Randeep

    2014-10-01

    Multiple tracheal diverticulosis is a rare clinical entity. Tracheal diverticula are usually recognized radiologically as solitary right paratracheal air collections on thoracic computed tomography examination. They are usually asymptomatic but can occasionally present with persistent symptoms. We herein report the case of a 50-year-old male patient who underwent extensive evaluation for persistent cough. Multiple posterior right paratracheal air collections were recognized on thoracic multidetector computed tomography examination, which was confirmed as multiple-acquired posterior upper tracheal diverticula on flexible bronchoscopy. The patient improved with conservative medical management.

  6. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  7. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve.

    Science.gov (United States)

    Khan, Jaffar M; Rogers, Toby; Schenke, William H; Greenbaum, Adam B; Babaliaros, Vasilis C; Paone, Gaetano; Ramasawmy, Rajiv; Chen, Marcus Y; Herzka, Daniel A; Lederman, Robert J

    2018-02-06

    Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm 2 to 3.8 ± 1.5 cm 2 (naïve) and 13.1 ± 1.5 cm 2 to 6.2 ± 1.0 cm 2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  9. A randomized trial comparing skin closure in cesarean section: interrupted suture with nylon vs subcuticular suture with No '1' polyfilament.

    Science.gov (United States)

    Shrestha, A; Napit, J; Neupane, B; Sedhai, L B

    2013-09-01

    Cesarean section is one of the most commonly performed operations in most countries of the world including Nepal. Hence there is a load on the financial resources of healthcare system. The rational of this study was to utilize the remaining No '1' polyfilament after closing rectus sheath to stitch skin. So, the primary objective was to determine the wound complication rates for subcuticular suture with No'1' petcryl (polyfilamentpolyglycolic acid) Vs intermittent suture with nylon 2-0 for skin closure at cesarean delivery and secondary objective was to compare postoperative pain and patient satisfaction about the scar. One hundred and thirty eight women undergoing cesarean section at Chitwan Medical College was randomized to either intermittent skin suture with nylon 2-0 or subcuticular with polyfilament No '1' (remaining suture after closing rectus sheath). Evidence of wound infection, pain and overall satisfaction were assessed postoperatively. The overall wound complications rate in subcuticular stitch with No'1' polyfilament suture were similar as in intermittent mattress stitch with nylon 2-0 (15.9% vs. 14.49%). Pain on postoperative third day and six weeks and overall satisfaction about wound were similar in both groups. Only prolong rupture of membrane >18 hours was found to be a significant risk factor of wound infection (OR: 3.4; p=0.04). The remaining no '1' polyfilament suture (petcryl) after suturing rectus sheath can be safely used to close skin suture in cesarean section.

  10. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  11. Meso-Tethyan oceanic sutures and their deformation

    Science.gov (United States)

    Burtman, V. S.

    1994-07-01

    On the basis of comparative stratigraphie and paleontologic analysis, supported by some key paleomagnetic data and interpretations, it is shown that during the Mesozoic and the Cenozoic the Eurasian continent grew by accretion of microcontinents. These microcontinents separated basins with oceanic crust from the main ocean. During the Late Cretaceous and the early Cenozoic the collision of the microcontinents with Eurasia resulted in the closure of the basins, and Meso-Tethyan oceanic sutures originated. In the region under consideration, from the Carpathians to Tibet, there are two main Meso-Tethyan sutures: the Carpathian-Lesser Caucasus and the Afghan-Tibet suture. The above-mentioned main structures also had branches, which remained as sutures of small basins: the Kamennopotock, Interpontide, Nain-Baft basins and others. In the West Carpathians the Carpathian-Lesser Caucasus suture is overlain by a widespread Gemeric-Tatric allochton. From the West Carpathians the suture passes through the Pannonian basin into the Vardar ophiolite zone and farther to the ophiolites of the Izmir-Ankara zone. Being displaced along the North Anatolian right-lateral strike-slip fault, the main suture passes from the Eastern Pontides into the Lesser Caucasus, where it is marked by ophiolites of the Amasia area, the Shirak, Bozum and Zangezur ridges. Sunsequently, it can be observed through the Iranian Qara Dagh mountains to Lake Urumiyeh and the North Anatolian strike-slip fault. Being again shifted along the strike-slip fault, the Carpathian-Lesser Caucasus Meso-Tethyan suture ends in the Western Zagros near the Cenozoic Neo-Tethyan suture. The Afghan-Tibet Meso-Tethyan suture is situated in the Pamirs in the Rushan-Pshart zone. The east prolongation of the suture has been displaced along the Pamir-Karakorum right-lateral strike-slip fault in Tibet. West of the Pamirs this suture is also displaced along strike-slip faults and continues in the Farahrud zone in Afghanistan, and than

  12. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  13. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  14. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  15. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  16. Cosmetic outcomes of cesarean section scar; subcuticular suture versus intradermal buried suture.

    Science.gov (United States)

    Yang, Juseok; Kim, Ki Hyung; Song, Yong Jung; Kim, Seung-Chul; Sung, Nayoung; Kim, Haneul; Lee, Dong Hyung

    2018-01-01

    The objective of the study was to compare cosmetic outcomes and overall satisfaction rate of cesarean section scar between conventional subcuticular suture and intradermal buried vertical mattress. Patients were enrolled to the study by chart review. A scar assessment was obtained retrospectively through a telephone survey. The patient component of the patient and observer scar assessment scale (POSAS) was utilized along with the overall satisfaction of the patient regarding their cesarean section scar and their willingness to choose the same skin closure technique when anticipating their next cesarean section. A total of 303 cases of cesarean section was recruited, 102 finished telephone surveys were calculated for the analyses. Subcuticular suture was regarded as control group (n=52) and intradermal buried suture as test group (n=50). The PSAS score of the test group (mean, 21.8) was lower than that of the control group (mean, 28), with a statistical significance ( P =0.02). Overall satisfaction rate did not differ between the two groups. Two parameters of the PSAS score and the level of overall satisfaction showed significant correlation (Pearson's r , -0.63; P cesarean sections over subcuticular stitch.

  17. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  18. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  19. [Cystourethroanastomosis in extended obliterations and strictures of the posterior urethra in men].

    Science.gov (United States)

    Mitusov, V V; Aboian, I A

    2005-01-01

    The authors review short- and long-term clinical results of surgical treatment of extended urethral strictures and obliterations. A new vesicourethral anastomosis was created by novel technique with longitudinal suturing of the neck of the urinary bladder. A scheme of the operation is presented. Causes necessitating this plastic intervention are analysed. Variants of possible urine incontinence after operation depending on etiological cause of the stricture or obliteration of the posterior urethra in males are considered.

  20. A Mechanical Evaluation of Zone II Flexor Tendon Repair Using a Knotless Barbed Suture Versus a Traditional Braided Suture.

    Science.gov (United States)

    Nayak, Aniruddh N; Nguyen, Dzi-Viet; Brabender, Robert C; Hiro, Matthew E; Miles, Jeremy J; Smithson, Ian R; Santoni, Brandon G; Stone, Jeffery D; Hess, Alfred V

    2015-07-01

    To determine repair site bulk, gliding resistance, work of flexion, and 1-mm gap formation force in zone II flexor tendon lacerations repaired with knotless barbed or traditional braided suture. Transverse zone II lacerations of the flexor digitorum profundus (FDP) tendon were created in 36 digits from 6 matched human cadaveric pairs. Repair was performed with 2-0 barbed suture (n = 18) or 3-0 polyethylene braided suture (n = 18). Pre- and postrepair cross-sectional area was measured followed by quantification of gliding resistance and work of flexion during cyclic flexion-extension loading at 10 mm/min. Thereafter, the repaired tendons were loaded to failure. The force at 1 mm of gap formation was recorded. Repaired FDP tendon cross-sectional area increased significantly from intact, with no difference noted between suture types. Gliding resistance and work of flexion were significantly higher for both suture repairs; however, we identified no significant differences in either nondestructive biomechanical parameters between repair types. Average 1-mm gap formation force with the knotless barbed suture (52 N) was greater than that of the traditional braided suture (43 N). We identified no significant advantage in using knotless barbed suture for zone II FDP repair in our primary, nondestructive mechanical outcomes in this in vitro study. In vivo studies may be warranted to determine if one suture method has an advantage with respect to the parameters tested at 4, 6, and 12 plus weeks postrepair and the degree of adhesion formation. The combined laboratory and clinical data, in additional to cost considerations, may better define the role of barbed knotless suture for zone II flexor tendon repair. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  2. Complications with mechanical suture use in colorectal surgery

    International Nuclear Information System (INIS)

    Bruno, G.; Ruso, L.; Gatti, A.; Quiros, F.; Balboa, O.

    1998-01-01

    The great development of mechanical suture and its qualitative impact in colorectal surgery has not been able to avoid persistent mortality due to suture failure which is still about 5% and rectal stenosis, which is significantly higher than with manual sutures.The present paper analyses 63 cases of colorrectal anastomosis performed of coordination with mechanical suture at CASMU, in a period of four years (1991-1995).There were 51 rectum resections and colorrectal anastomosis and 12 reconstruction of intestinal transit.There were 28 females and 35 males with and average age of 66 years.Three patients died (4,7%), 20 (31,7%) suffered various complications among which some are pointed out in relation to mechanical suture to suture failures(3,1%) who died and 8 rectal stenosis(12,9%)with favourable evolution after dilations.The authors analyse the issues that incide on the production of complications in colorrectal surgery and conclude that the incidence of global complications in their series is elevated, although mortality, suture failure and rectal stenosis figures are comparable to those in international literature analysed.The incidence of machine width proximal ostomies and radiotherapy on the development of stenosis in our milieu require a multicentric studie with a greater number of patients

  3. Arthroscopic Stabilization of Posterior Shoulder Instability Is Successful in American Football Players.

    Science.gov (United States)

    Arner, Justin W; McClincy, Michael P; Bradley, James P

    2015-08-01

    To evaluate subjective and objective clinical outcomes of arthroscopic posterior capsulolabral repair for the treatment of symptomatic unidirectional posterior shoulder instability in American football players. Fifty-six consecutive American football players with unidirectional posterior shoulder instability underwent an arthroscopic posterior capsulolabral repair with or without suture anchors. Patients were evaluated, with return to play as the primary outcome measure supplemented with the American Shoulder and Elbow Surgeons (ASES) scoring system. Stability, range of motion, strength, pain, and function were also assessed with subjective scales. At a mean follow-up of 44.7 months postoperatively, 93% returned to sport and 79% returned to sport at the same level. Significant improvements (P 60; stability American football players because it improves stability, pain, and joint function, which optimizes the likelihood of successful return to play. Case series; Level of evidence, IV. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Vertical muscle transposition augmented with lateral fixation (Foster) suture for Duane syndrome and sixth nerve palsy.

    Science.gov (United States)

    Akar, S; Gokyigit, B; Pekel, G; Demircan, A; Demirok, A

    2013-10-01

    To report the postoperative results of full-tendon vertical rectus transposition (VRT) augmented with lateral fixation suture for the treatment of type 1 Duane syndrome and sixth nerve palsy and to determine whether there was a decrease in the effect of the Foster suture over time. This retrospective, consecutive case series included patients who underwent a full-tendon VRT transposition with lateral fixation for type 1 Duane syndrome or sixth nerve palsy. The primary outcome measures included deviation, abnormal head posture(AHP), abduction deficiency, and postoperative binocular single visual field (BSVF). Eighty-seven patients (87 eyes: 40 eyes with Duane syndrome and 47 eyes with sixth nerve palsy) were included in this study. In Duane syndrome patients, the deviation was reduced by a mean of 95%, the AHP was eliminated in 86% of patients, the abduction was improved by 42%, and a useful BSVF of ≈ 67% of normal was achieved at 1 year post operation. In sixth nerve palsy patients, the deviation was reduced by 99%, the abduction was improved by 59%, and a useful BSVF of ≈ 71% of normal was achieved at 1 year post operation. In both groups, the improvements in deviation angle and abduction were stable postoperatively. Sixteen patients needed reoperation for undercorrection. VRT surgery with posterior fixation is an effective treatment method for complete sixth nerve palsy and Duane syndrome with esotropia, AHP, and abduction deficiency. The procedure carries a small risk of reoperation for undercorrection. The effect of the Foster suture did not decline over time.

  5. Posterior Reversible Encephalopathy (PRES)

    International Nuclear Information System (INIS)

    Moron E, Fanny E; Diaz Marchan, Pedro

    2005-01-01

    The Posterior Reversible Encephalopathy Syndrome (PRES) is a clinical Syndrome composed of cephalea, alteration in vision and convulsions, usually observed in patients with sudden elevation of arterial pressure. The imagenologic evidence shows reversible vasogenic brain edema without stroke. Its location is predominantly posterior; it affects the cortex and the subcortical white matter of the occipital, parietal and temporal lobes. The treatment with antihypertensive drugs and the removing of immunosupressor medication are generally associated with complete neurological recovery; this is reflected also in the images which return to their basal condition. The untreated hypertension, on the other side, can result in a progressive defect of the autoregulation system of the central nervous system with cerebral hemorrhage, irreversible brain stroke, coma and death

  6. Bacterial adhesion to suture material in a contaminated wound model: Comparison of monofilament, braided, and barbed sutures.

    Science.gov (United States)

    Dhom, Jonas; Bloes, Dominik A; Peschel, Andreas; Hofmann, Ulf K

    2017-04-01

    Contaminated suture material plays an important role in the physiopathology of surgical site infections. Recently, suture material has been developed characterized by barbs projecting from a monofilament base. Claimed advantages for barbed sutures are a shortened wound closure time and reduced maximum wound tension. It has also been suggested that these sutures would be advantageous microbiologically. The aim of this study was to test the microbiological characteristics of the barbed Quill in comparison to the monofilament Ethilon II and the braided sutures Vicryl and triclosan-coated Vicryl Plus. In our study, sutures were cultivated on color-change agar with Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, Escherichia coli, and Pseudomonas aeruginosa and the halo size was measured. In a second study arm with longer cultivation bacterial growth was followed by antibiotic treatment. Ethilon II and Quill showed good comparable results, whereas large halos were found around Vicryl. Vicryl Plus results depended on triclosan sensitivity. After longer bacterial cultivation and antibiotic treatment, halos were up to 3.6 times smaller on Quill than on Vicryl (p barbs on Quill. From a microbiological perspective, barbed sutures can be recommended in aseptic surgery, but should only be used carefully in septic surgery. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:925-933, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. MonoMax Suture: A New Long-Term Absorbable Monofilament Suture Made from Poly-4-Hydroxybutyrate

    Directory of Open Access Journals (Sweden)

    Erich K. Odermatt

    2012-01-01

    Full Text Available A long-term absorbable monofilament suture was developed using poly-4-hydroxybutyrate (P4HB made from a biosynthetically produced homopolymer of the natural metabolite 4-hydroxybutyrate. The suture, called MonoMax, has prolonged strength retention. At 12 weeks, a size 3-0 MonoMax suture retains approximately 50% of its initial tensile strength in vivo and is substantially degraded in one year with minimal tissue reaction. In contrast, PDS II monofilament suture (Ethicon, Inc., Somerville, NJ has no residual strength in vivo after 12 weeks. In vivo, the MonoMax suture is hydrolyzed primarily by bulk hydrolysis, and is then degraded via the Krebs cycle. MonoMax is substantially more compliant than other monofilament sutures, and incorporates an element of elasticity. Its tensile modulus of 0.48 GPa is approximately one-third of the value of the PDS II fiber providing an exceptionally flexible and pliable fiber with excellent knot strength and security. These features are further enhanced by the fiber's elasticity, which also improves knot security and may help prevent wound dehiscence. Because of its performance advantages, this suture may find clinical utility in applications where prolonged strength retention, and greater flexibility are required, particularly in procedures like abdominal wall closure where wound dehiscence is still a significant post-surgical complication.

  8. Target Chamber Manipulator

    Science.gov (United States)

    Tantillo, Anthony; Watson, Matthew

    2015-11-01

    A system has been developed to allow remote actuation of sensors in a high vacuum target chamber used with a particle accelerator. Typically, sensors of various types are placed into the target chamber at specific radial and angular positions relative to the beam line and target. The chamber is then evacuated and the experiments are performed for those sensor positions. Then, the chamber is opened, the sensors are repositioned to new angles or radii, and the process is repeated, with a separate pump-down cycle for each set of sensor positions. The new sensor positioning system allows scientists to pre-set the radii of up to a dozen sensors, and then remotely actuate their angular positions without breaking the vacuum of the target chamber. This reduces the time required to reposition sensors from 6 hours to 1 minute. The sensors are placed into one of two tracks that are separately actuated using vacuum-grade stepping motors. The positions of the sensors are verified using absolute optical rotary encoders, and the positions are accurate to 0.5 degrees. The positions of the sensors are electronically recorded and time-stamped after every change. User control is through a GUI using LabVIEW.

  9. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Science.gov (United States)

    Sánchez-Castro, Grimelda Yuriana; Hitos-Fájer, Alejandra; Mendoza-Schuster, Erick; Velez-Montoya, Raul; Velasco-Barona, Cecilio Francisco

    2008-01-01

    We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema. PMID:19668770

  10. Mixing processes in the vitreous chamber induced by eye rotations

    International Nuclear Information System (INIS)

    Stocchino, Alessandro; Repetto, Rodolfo; Siggers, Jennifer H

    2010-01-01

    In this paper, we study a model of flow in the vitreous humour in the posterior chamber of the human eye, induced by saccadic eye rotations. We concentrate on the effect of the shape of the chamber upon the mixing properties of the induced flows. We make particle image velocimetry measurements of the fluid velocity in a transparent plastic (Perspex) model of the posterior chamber during sinusoidal torsional oscillations about a vertical axis. We use a Newtonian fluid to model the vitreous humour, which is most realistic when either the vitreous humour is liquefied or has been replaced by purely viscous tamponade fluids. The model of the posterior chamber is a sphere with an indentation, representing the effect of the lens. In spite of the purely periodic forcing, a steady streaming flow is generated, which plays a fundamental role in the mixing processes in the domain. The streaming flow differs markedly from that in a perfect sphere, and its topological characteristics change substantially as the frequency of oscillation varies. We discuss the flow characteristics in detail and show that, for physiological parameter values, the Peclet number (based on a suitable measure of the steady streaming velocity) is large, suggesting that advection strongly dominates over diffusion for mass transport phenomena. We also compute particle trajectories based on the streaming velocity and use these to investigate the stirring properties of the flow.

  11. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  12. The KLOE drift chamber

    CERN Document Server

    Adinolfi, M; Ambrosino, F; Andryakov, A; Antonelli, A; Antonelli, M; Anulli, F; Bacci, C; Bankamp, A; Barbiellini, G; Bellini, F; Bencivenni, G; Bertolucci, Sergio; Bini, C; Bloise, C; Bocci, V; Bossi, F; Branchini, P; Bulychjov, S A; Cabibbo, G; Calcaterra, A; Caloi, R; Campana, P; Capon, G; Carboni, G; Cardini, A; Casarsa, M; Cataldi, G; Ceradini, F; Cervelli, F; Cevenini, F; Chiefari, G; Ciambrone, P; Conetti, S; Conticelli, S; Lucia, E D; Robertis, G D; Sangro, R D; Simone, P D; Zorzi, G D; Dell'Agnello, S; Denig, A; Domenico, A D; Donato, C D; Falco, S D; Doria, A; Drago, E; Elia, V; Erriquez, O; Farilla, A; Felici, G; Ferrari, A; Ferrer, M L; Finocchiaro, G; Forti, C; Franceschi, A; Franzini, P; Gao, M L; Gatti, C; Gauzzi, P; Giovannella, S; Golovatyuk, V; Gorini, E; Grancagnolo, F; Grandegger, W; Graziani, E; Guarnaccia, P; Von Hagel, U; Han, H G; Han, S W; Huang, X; Incagli, M; Ingrosso, L; Jang, Y Y; Kim, W; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Lomtadze, F; Luisi, C; Mao Chen Sheng; Martemyanov, M; Matsyuk, M; Mei, W; Merola, L; Messi, R; Miscetti, S; Moalem, A; Moccia, S; Moulson, M; Müller, S; Murtas, F; Napolitano, M; Nedosekin, A; Panareo, M; Pacciani, L; Pagès, P; Palutan, M; Paoluzi, L; Pasqualucci, E; Passalacqua, L; Passaseo, M; Passeri, A; Patera, V; Petrolo, E; Petrucci, Guido; Picca, D; Pirozzi, G; Pistillo, C; Pollack, M; Pontecorvo, L; Primavera, M; Ruggieri, F; Santangelo, P; Santovetti, E; Saracino, G; Schamberger, R D; Schwick, C; Sciascia, B; Sciubba, A; Scuri, F; Sfiligoi, I; Shan, J; Silano, P; Spadaro, T; Spagnolo, S; Spiriti, E; Stanescu, C; Tong, G L; Tortora, L; Valente, E; Valente, P; Valeriani, B; Venanzoni, G; Veneziano, Stefano; Wu, Y; Xie, Y G; Zhao, P P; Zhou, Y

    2001-01-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K sub L produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm sup 2 in size in the 12 innermost layers and 3x3 cm sup 2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented.

  13. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Adinolfi, M.; Aloisio, A.; Ambrosino, F.; Andryakov, A.; Antonelli, A.; Antonelli, M.; Anulli, F.; Bacci, C.; Bankamp, A.; Barbiellini, G.; Bellini, F.; Bencivenni, G.; Bertolucci, S.; Bini, C.; Bloise, C.; Bocci, V.; Bossi, F.; Branchini, P.; Bulychjov, S.A.; Cabibbo, G.; Calcaterra, A.; Caloi, R.; Campana, P.; Capon, G.; Carboni, G.; Cardini, A.; Casarsa, M.; Cataldi, G.; Ceradini, F.; Cervelli, F.; Cevenini, F.; Chiefari, G.; Ciambrone, P.; Conetti, S.; Conticelli, S.; Lucia, E. De; Robertis, G. De; Sangro, R. De; Simone, P. De; Zorzi, G. De; Dell'Agnello, S.; Denig, A.; Domenico, A. Di; Donato, C. Di; Falco, S. Di; Doria, A.; Drago, E.; Elia, V.; Erriquez, O.; Farilla, A.; Felici, G.; Ferrari, A.; Ferrer, M.L.; Finocchiaro, G.; Forti, C.; Franceschi, A.; Franzini, P.; Gao, M.L.; Gatti, C.; Gauzzi, P.; Giovannella, S.; Golovatyuk, V.; Gorini, E.; Grancagnolo, F.; Grandegger, W.; Graziani, E.; Guarnaccia, P.; Hagel, U.V.; Han, H.G.; Han, S.W.; Huang, X.; Incagli, M.; Ingrosso, L.; Jang, Y.Y.; Kim, W.; Kluge, W.; Kulikov, V.; Lacava, F.; Lanfranchi, G.; Lee-Franzini, J.; Lomtadze, F.; Luisi, C.; Mao, C.S.; Martemianov, M.; Matsyuk, M.; Mei, W.; Merola, L.; Messi, R.; Miscetti, S.; Moalem, A.; Moccia, S.; Moulson, M.; Mueller, S.; Murtas, F.; Napolitano, M.; Nedosekin, A.; Panareo, M.; Pacciani, L.; Pages, P.; Palutan, M.; Paoluzi, L.; Pasqualucci, E.; Passalacqua, L.; Passaseo, M.; Passeri, A.; Patera, V.; Petrolo, E.; Petrucci, G.; Picca, D.; Pirozzi, G.; Pistillo, C.; Pollack, M.; Pontecorvo, L.; Primavera, M.; Ruggieri, F.; Santangelo, P.; Santovetti, E.; Saracino, G.; Schamberger, R.D.; Schwick, C.; Sciascia, B.; Sciubba, A.; Scuri, F.; Sfiligoi, I.; Shan, J.; Silano, P.; Spadaro, T.; Spagnolo, S.; Spiriti, E.; Stanescu, C.; Tong, G.L.; Tortora, L.; Valente, E.; Valente, P.; Valeriani, B.; Venanzoni, G.; Veneziano, S.; Wu, Y.; Xie, Y.G.; Zhao, P.P.; Zhou, Y.

    2001-01-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K L produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm 2 in size in the 12 innermost layers and 3x3 cm 2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented

  14. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  15. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  16. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  17. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    Directory of Open Access Journals (Sweden)

    Swati R Yedke

    2013-01-01

    Full Text Available Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3 rd and 7 th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries.

  18. SUTURE NON-SUTSRE CIRCUMFERENTIAL REPAIR OF CAROTID ARTERY

    Directory of Open Access Journals (Sweden)

    Jafar Nader

    1969-01-01

    Full Text Available plastic adhesives, normal butyl cyanoacrylate monomer, isobutyl cyanoacrylate monomer and methyl 2 _ cyaooacrylate monomer, have been utilized in a comparative study with 5-{ silk suture in the repair of transected carotid arteries. Follow _ up arteriog ramS indicate isobutyl cyanoacrylate monomer and normal butyl cyanoacrylate monomer as having the most impressive rerults with only tWO thrombosis each. The silk suture had three thromboses and the adhesive methyl 2 _ cyanoacrylate monomer had nine, one of which a delayed

  19. The Efficacy of Polydioxanone Monofilament Absorbable Suture for Tracheal Anastomosis

    OpenAIRE

    Kawahara, Katsunobu; Yamasaki, Naoya; Yamamoto, Satoshi; Nagayasu, Takeshi; Kusano, Hiroyuki; Akamine, Shinji; Takahashi, Takao; Tomita, Masao

    1994-01-01

    To evaluate the efficacy of polydioxanon absorbable suture for tracheal anastomoses, we performed an experimental study using dose. Eight adult mongrel dogs underwent sleeve resection of the mediastinal trachea. A length of ten to twelve cartilage rings was resected. An end-to-end anastomosis was performed using either interrupted or continuous running 4-0 polydioxanone (PDS) suture. There was no detectable difference bronchoscopically, microangiografically, or histologically, in tracheal ana...

  20. Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.

    Science.gov (United States)

    Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher

    2016-03-01

    To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. [Clinical experience in using a metallic suture in eye microsurgery].

    Science.gov (United States)

    Kumar Vinod, Dushin N V

    2003-01-01

    The use of a metallic suture in eye microsurgery is described in the paper. The metallic suture made from a 0.05-0.05 mm vanadic stainless steel wire (corresponding to 8:0) was applied in 1202 cataract extractions, penetrating injuries, antiglaucomatous surgeries and in removal of pterygium at the medical-and-sanitary facility of steel works in the town of Bokaro (India). The observation period ranged, on the average, from 3 months to 3 years. There were no complications during the procedure of applying the suture. However, it caused a minor response in the ocular tissues during the early postoperative period. Small bullae were observed in the corneal surface near the suture in 7 cases (0.58%), which disappeared spontaneously in 3-4 days. Irritations inflicted by the suture ends were registered in 2.58% of cases (31 patients). The mean postoperative astigmatism was, 3 months after surgery, 1.65 diopters. The sutures were removed in 132 cases (10.98%), including in 16 patients with irritation, and in 116 patients for the purpose of correcting a high astigmatism. The share of patients with a visual acuity of 0.5 and higher was, in one week, 43.59% and went up, one month later, to 78.20%. The suture was well tolerated by patients, it was quickly covered by the corneal epithelium, there was no rejection and it can be easily manufactured. The suture is sterilized by routine techniques without need for any extra treatment before use; it is a reactive, biologically inactive, efficient, convenient and causes minimal operative and postoperative complications.

  2. A New Coating for Non-resorbable Surgical Suture

    Directory of Open Access Journals (Sweden)

    Ahmed Salah Hameed

    2017-12-01

    Full Text Available Suture is a biomaterial used to approximate wound edges to facilitate the healing process. This task could be compromised as a result of wound infection. Zinc is an element that has antibacterial action and can be a member of silicate glasses. The zinc-silicate glasses can be used as a coating for surgical suture to combat wound infection. However, zinc has a negative effect on glass degradation and its  antibacterial action is a pH sensitive. In this work, silicate glasseswith ZnO at 14 and 17 mole% were used as a coating for non-resorbable Mersilk suture using a slurry-dipping technique. The coating morphology was studied using SEM and itsanti-bacterial action was investigated in vitroagainstgram positive and negative bacteria at neutral and acidic conditions.The effect of the coating on tensile strength of the sutures wasstudied as well.The results revealed that the coatingwas well-adhered to the suture and had anti-bacterial action atacidic condition.The coating had no effect on the tensile strength of the surgical suture

  3. Suture techniques in nasal tip sculpture: current concepts.

    Science.gov (United States)

    Lo, S; Rowe-Jones, J

    2007-08-01

    The three-dimensional anatomy and conspicuous location of the nasal tip makes it one of the most challenging sites of facial plastic surgery. This article reviews literature on nasal tip sculpture using suture techniques, as well as the authors' own experience. A search was conducted using Pubmed, the Google internet search engine and the authors' files, using the keywords 'nasal tip', 'suture', 'rhinoplasty' and 'septorhinoplasty'. Common nasal tip suture techniques and suture algorithms are presented, along with a summary of the indications and side effects of each technique. Predictable long-term results are more likely to occur with minimal local tissue excision. Suture techniques remodel the shape of the nasal tip by altering the configuration of, and the relationship between, the tip cartilages and their supporting structures; they also preserve nasal tip anatomy and limit resection. Intra-operatively, the effects are immediately visible, and can be adjusted or reversed. Tip sutures should therefore be considered instead of tissue excision whenever possible.

  4. Development of braided drug-loaded nanofiber sutures

    International Nuclear Information System (INIS)

    Hu Wen; Huang Zhengming; Liu Xiangyang

    2010-01-01

    The objectives of this work are twofold. Firstly, while most work on electrospinning is limited to the development of only functional materials, a structural application of electrospun nanofibers is explored. Secondly, a drug-loaded tissue suture is fabricated and its various properties are characterized. Braided drug-loaded nanofiber sutures are obtained by combining an electrospinning process with a braiding technique followed by a coating procedure. Two different electrospinning techniques, i.e. blend and coaxial electrospinning, to incorporate a model drug cefotaxime sodium (CFX-Na) into poly(L-lactic acid) (PLLA) nanofibers have been applied and compared with each other. Properties of the braided drug-loaded sutures are characterized through a variety of methods including SEM, TEM and tensile testing. The results show that the nanofibers had a preferable micromorphology. The drug was incorporated into the polymer nanofibers homogeneously, with no cross-linking. The nanofibers maintained their fibrous structures. An in vitro release study indicates that the drug-loaded nanofibers fabricated by blend electrospinning and coaxial electrospinning had a different drug release behavior. An inhibition zone experiment shows that both sutures obtained from the nanofibers of the different electrospinning techniques had favorable antibacterial properties. The drug-loaded sutures had preferable histological compatibility performance compared with commercial silk sutures in an in vivo comparative study.

  5. Large planar drift chambers

    CERN Document Server

    Marel, Gérard; Bréhin, S; Devaux, B; Diamant-Berger, Alain M; Leschevin, C; Maillard, J; Malbequi, Y; Martin, H; Patoux, A; Pelle, J; Plancoulaine, J; Tarte, Gérard; Turlay, René

    1977-01-01

    The authors describe 14 m/sup 2/ hexagonal planar drift chambers designed for the neutrino experiment of the CERN-Dortmund-Heidelberg- Saclay Collaboration. Details on mechanical construction, electronic read-out, results on efficiency and accuracy are presented. (6 refs).

  6. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  7. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  8. Review of straw chambers

    International Nuclear Information System (INIS)

    Toki, W.H.

    1990-03-01

    This is a review of straw chambers used in the HRS, MAC, Mark III, CLEO, AMY, and TPC e + e - experiments. The straws are 6--8 mm in diameter, operate at 1--4 atmospheres and obtain resolutions of 45--100 microns. The designs and constructions are summarized and possible improvements discussed

  9. Heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The CERN Heavy liquid bubble chamber being installed in the north experimental hall at the PS. On the left, the 1180 litre body; in the centre the magnet, which can produce a field of 26 800 gauss; on the right the expansion mechanism.

  10. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  11. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  12. Scanning bubble chamber pictures

    CERN Multimedia

    1974-01-01

    These were taken at the 2 m hydrogen bubble chamber. The photo shows an early Shiva system where the pre-measurements needed to qualify the event were done manually (cf photo 7408136X). The scanning tables were located in bld. 12. Gilberte Saulmier sits on foreground, Inge Arents at centre.

  13. Chamber Profile Measurement System.

    Science.gov (United States)

    1980-10-01

    travel with the proper electronics. Other features of tihe gage assembly are: 1. Micrometer controlled down chamber positioning of the master template to...pressure sensitive "stiff stick" for infinitely varying the rate of travel from zero to maximum. A manual vernier control is incorporated to permit fine

  14. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  15. Drift Chambers detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez laso, L.

    1989-01-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs

  16. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Ferrari, A.

    2002-01-01

    The design and construction of the large drift chamber of the KLOE experiment is presented. The track reconstruction is described, together with the calibration method and the monitoring systems. The stability of operation and the performance are studied with samples of e + e - , K S K L and K + K - events

  17. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  18. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  19. Microbiological profile of anterior chamber aspirates following uncomplicated cataract surgery

    Directory of Open Access Journals (Sweden)

    Prajna N

    1998-01-01

    Full Text Available Anterior chamber aspirate cultures were done for 66 patients who underwent either an uncomplicated intracapsular cataract extraction, extracapsular cataract extraction with posterior-chamber intraocular lens implantation, or phacoemulsification with posterior-chamber intraocular lens implantation. The aspirate was obtained at the time of wound closure. The aspirates were immediately transferred to the microbiology laboratory where one drop of the aspirate was placed on a glass slide for gram stain, and the remainder was unequally divided and inoculated into blood agar, chocolate agar and thioglycolate broth. The cultures were incubated at 37° C with 5% CO2 and held for 5 days. Of 66 patients 4 (6%, had smear-positive anterior chamber aspirates. None of the aspirates showed any growth on any of the 3 culture media used. None of the eyes in the study developed endophthalmitis. This study concludes that there is no contamination of the anterior chamber by viable bacteria after cataract surgery, irrespective of the mode of intervention.

  20. Reversible posterior leukoencephalopathy syndrome

    International Nuclear Information System (INIS)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won; Song, Chang Joon; Song, Soon-Young; Koo, Ja Hong; Kim, Man Deuk

    2001-01-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  1. Posterior Urethral Strictures

    Directory of Open Access Journals (Sweden)

    Joel Gelman

    2015-01-01

    Full Text Available Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty.

  2. Posterior Urethral Strictures

    Science.gov (United States)

    Gelman, Joel; Wisenbaugh, Eric S.

    2015-01-01

    Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883

  3. Reversible posterior leukoencephalopathy syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won [The Catholic Univ. of Korea, Taejon (Korea, Republic of); Song, Chang Joon [Chungnam National Univ. School of Medicine, Cheonju (Korea, Republic of); Song, Soon-Young; Koo, Ja Hong [Kwandong Univ. College of Medicine, Myungji Hospital, Seoul (Korea, Republic of); Kim, Man Deuk [College of Medicine Pochon CHA Univ., Seoul (Korea, Republic of)

    2001-10-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  4. Why make monofilament sutures out of polyvinylidene fluoride?

    Science.gov (United States)

    Urban, E; King, M W; Guidoin, R; Laroche, G; Marois, Y; Martin, L; Cardou, A; Douville, Y

    1994-01-01

    In recent years some clinical reports have associated suture failures with polypropylene monofilaments. Therefore there is interest in developing an alternative suture material that is less thrombogenic than polyester and similar in handling characteristics but less prone to mechanical failure than polypropylene. To this end, Peters Laboratoire Pharmaceutique has developed a new monofilament suture material from polyvinylidene fluoride (PVDF), which has been subjected to a special treatment to modify its crystalline form and level of crystallinity. The purpose of this study was to evaluate its mechanical, chemical, and biologic properties and to compare its performance, in a peripheral vascular application, to that of a polypropylene control. A series of in vitro tests were performed to study the morphology, tensile properties, creep, surface chemistry, thermal characteristics, and resistance to iatrogenic trauma. In addition, an in vivo trial was undertaken in which vascular prostheses anastomosed with either PVDF or polypropylene sutures were implanted as a thoracoabdominal bypass for 6 months in the dog. Histologic and degradation analyses were performed on the explants. The results from the mechanical tests on 4-0, 5-0, and 6-0 PVDF and polypropylene sutures demonstrated that although both materials have similar breaking strengths, the PVDF has a higher extension at break, has less delayed extension when under tensile creep testing, and suffers less trauma than the polypropylene when compressed by a standard needle holder. While chemical analyses found evidence of surface oxidation on both types of sutures, thermal analysis confirmed that the level of crystallinity of the PVDF polymer is higher than that of the polypropylene control. During the pilot study in animals, PVDF sutures were found to have good handling and frictional characteristics that facilitated the tying of knots. Histologic analysis of the explants found no inflammatory cells in the tissue

  5. Novel Spiked-Washer Repair Is Biomechanically Superior to Suture and Bone Tunnels for Arcuate Fracture Repair.

    Science.gov (United States)

    Vojdani, Saman; Fernandez, Laviel; Jiao, Jian; Enders, Tyler; Ortiz, Steven; Lin, Liangjun; Qin, Yi-Xian; Komatsu, David E; Penna, James; Ruotolo, Charles J

    2017-03-01

    Injuries to the posterolateral corner of the knee can lead to chronic degenerative changes, external rotation instability, and varus instability if not repaired adequately. A proximal fibula avulsion fracture, referred to as an arcuate fracture, has been described in the literature, but a definitive repair technique has yet to be described. The objective of this study was to present a novel arcuate fracture repair technique, using a spiked-washer with an intramedullary screw, and to compare its biomechanical integrity to a previously described suture and bone tunnel method. Ten fresh-frozen cadaveric knees underwent a proximal fibula osteotomy to simulate a proximal fibula avulsion fracture. The lateral knee capsule and posterior cruciate ligament were also sectioned to create maximal varus instability. Five fibulas were repaired using a novel spiked-washer technique and the other 5 were repaired using the suture and bone tunnel method. The repaired knees were subjected to a monotonic varus load using a mechanical testing system instrument until failure of the repair or associated posterolateral corner structures. Compared with the suture repair group, the spiked-washer repair group demonstrated a 100% increase in stiffness, 100% increase in yield, 110% increase in failure force, and 108% increase in energy to failure. The spiked-washer technique offers superior quasi-static biomechanical performance compared with suture repair with bone tunnels for arcuate fractures of the proximal fibula. Further clinical investigation of this technique is warranted and the results of this testing may lead to improved outcomes and patient satisfaction for proximal fibula avulsion fractures.

  6. Arthroscopic Trapeziectomy With Suture Button Suspensionplasty

    Science.gov (United States)

    Landes, Genevieve; Gaspar, Michael P.; Goljan, Peter; Jacoby, Sidney M.; Bachoura, Abdo; Culp, Randall W.

    2016-01-01

    Background: Arthroscopic trapeziectomy with suture button suspensionplasty (ATBS) is a relatively new surgical option for the treatment of thumb carpometacarpal (CMC) osteoarthritis. Although ATBS has many potential benefits over alternative surgical treatments for CMC arthritis, little data exist regarding its safety and complication rates. The purpose of this study was to demonstrate that ATBS is associated with a low risk of complications within 1 year of surgery. Methods: A retrospective review of patients treated with ATBS by one senior hand surgeon over a span of 3 years was performed. Results: A total of 153 cases of ATBS were performed in 136 patients. Ninety-seven cases involved arthroscopic hemitrapeziectomies, and 56 involved arthroscopic complete trapeziectomies. There were 44 males and 92 females with a mean age of 62. Thirty-eight percent of the cases were graded as Eaton stage IV, 46% stage III, and 14% stage II CMC arthritis, while 3 cases (2%) were performed as revisions. Mean follow-up duration was 58 weeks. Mean preoperative key pinch strength of the affected versus the unaffected side was 92% compared with 95% postoperatively. Revision surgery was performed in 9 out of 153 cases (<6%). Of those 9 cases, 5 had additional minor bony debridement with subsequent improvement in pain, 3 had the implant repositioned due to button prominence, and 1 patient presented with osteomyelitis of the first and second metacarpals that was successfully treated with button removal and an antibiotic regimen. Conclusions: ATBS is a safe, minimally invasive procedure for treatment of symptomatic stages II through IV thumb CMC arthritis. PMID:27390569

  7. Outcomes of posterior-approach 'levatorpexy' in congenital ptosis repair.

    Science.gov (United States)

    Al-Abbadi, Zaid; Sagili, Suresh; Malhotra, Raman

    2014-12-01

    We describe a minimally invasive technique and report our experience of posterior approach levator plication ('levatorpexy') for congenital ptosis. Retrospective review. Consecutive series of 16 patients. Posterior approach levatorpexy was performed for congenital ptosis under general anaesthesia. This surgical procedure involves exposing the posterior surface of the levator muscle through a transconjunctival approach. The levator muscle is advanced and plicated using a suture passed through its posterior surface, partial-thickness, to tarsal plate and tied on the skin. No tissue (conjunctiva, Muller's muscle, levator) are excised during this procedure. Data collected included margin reflex distance (MRD1), symmetry of eyelid height, contour and complications. Surgery was considered successful if the following three criteria were simultaneously met: A postoperative MRD1 of ≥2 mm and ≤4.5 mm, inter-eyelid height asymmetry of ≤1 mm, and satisfactory eyelid contour. Mean age was 9.1 years (range 3-26 years). Mean postoperative follow-up was 8.1 months (4-24 months). Preoperative phenylephrine test was positive in 81% of patients. Mean levator function was 11 mm (5-15 mm). Mean preoperative MRD1 was 1.5 mm and the mean postoperative MRD1 was 2.6 mm. Fourteen patients (87%) achieved the desired eyelid height and fulfilled our criteria set for success. Posterior approach levatorpexy appears to be a safe and effective procedure for correction of congenital ptosis particularly with moderate or better levator function. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. [Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].

    Science.gov (United States)

    Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong

    2011-06-01

    For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.

  9. Inlay buccal mucosal graft for reoperative posterior urethroplasty

    Directory of Open Access Journals (Sweden)

    Shou-Hung Tang

    2012-04-01

    Full Text Available Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007–2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o’clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12–15 ml/seconds in all cases for a follow-up period of 18–30 months. The recurrence rate was 50% (2/4. Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases.

  10. Inlay buccal mucosal graft for reoperative posterior urethroplasty.

    Science.gov (United States)

    Tang, Shou-Hung; Kao, Chien-Chang; Wu, Seng-Tang; Meng, En; Cha, Tai-Lung

    2012-04-01

    Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007-2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o'clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12-15 ml/seconds in all cases for a follow-up period of 18-30 months. The recurrence rate was 50% (2/4). Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases. Copyright © 2012. Published by Elsevier B.V.

  11. Irreducible Traumatic Posterior Shoulder Dislocation

    Directory of Open Access Journals (Sweden)

    Blake Collier

    2017-01-01

    Full Text Available History of present illness: A 22-year-old male presented to the Emergency Department complaining of right shoulder pain after a motocross accident. He was traveling at approximately 10 mph around a turn when he lost control and was thrown over the handlebars, landing directly on his right shoulder. On arrival, he was holding his arm in adduction and internal rotation. An area of swelling was noted over his anterior shoulder. He was unable to abduct his shoulder. No humeral gapping was noted. He had normal neuro-vascular status distal to the injury. Significant findings: Radiographs demonstrated posterior displacement of the humeral head on the “Y” view (see white arrow and widening of the glenohumeral joint space on anterior-posterior view (see red arrow. The findings were consistent with posterior dislocation and a Hill-Sachs type deformity. Sedation was performed and reduction was attempted using external rotation, traction counter-traction. An immediate “pop” was felt during the procedure. Post-procedure radiographs revealed a persistent posterior subluxation with interlocking at posterior glenoid. CT revealed posterior dislocation with acute depressed impaction deformity medial to the biceps groove with the humeral head perched on the posterior glenoid, interlocked at reverse Hill-Sachs deformity (see blue arrow. Discussion: Posterior shoulder dislocations are rare and represent only 2% of all shoulder dislocations. Posterior shoulder dislocations are missed on initial diagnosis in more than 60% of cases.1 Posterior shoulder dislocations result from axial loading of the adducted and internally rotated shoulder, violent muscle contractions (resulting from seizures or electrocution, a direct posterior force applied to the anterior shoulder.1 Physical findings include decreased anterior prominence of the humeral head, increased palpable posterior prominence of the humeral head below the acromion, increased palpable prominence of the

  12. Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study.

    Directory of Open Access Journals (Sweden)

    Jia-Lin Wu

    Full Text Available Transtibial pullout suture (TPS repair of posterior medial meniscus root (PMMR tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG and conventional TPS repair. Twelve porcine tibiae (n = 6 each TG group: flexor digitorum profundus tendon was passed through an incision in the root area, created 5 mm postero-medially along the edge of the attachment area. TPS group: a modified Mason-Allen suture was created using no. 2 FiberWire. The tendon grafts and sutures were threaded through the bone tunnel and then fixed to the anterolateral cortex of the tibia. The two groups underwent cyclic loading followed by a load-to-failure test. Displacements of the constructs after 100, 500, and 1000 loading cycles, and the maximum load, stiffness, and elongation at failure were recorded. The TG technique had significantly lower elongation and higher stiffness compared with the TPS. The maximum load of the TG group was significantly lower than that of the TPS group. Failure modes for all specimens were caused by the suture or graft cutting through the meniscus. Lesser elongation and higher stiffness of the constructs in TG technique over those in the standard TPS technique might be beneficial for postoperative biological healing between the meniscus and tibial plateau. However, a slower rehabilitation program might be necessary due to its relatively lower maximum failure load.

  13. Prevention of Urethral Retraction with Stay Sutures (PURS) During Robot-Assisted Radical Prostatectomy Improves Early Urinary Control: A Prospective Cohort Study.

    Science.gov (United States)

    Argun, Omer Burak; Tuna, Mustafa Bilal; Doganca, Tunkut; Obek, Can; Mourmouris, Panagiotis; Tufek, Ilter; Erdogan, Sarper; Cetinel, Bulent; Kural, Ali Rıza

    2018-02-01

    To evaluate early continence rates with a novel modified vesicourethral anastomosis technique based on prevention of urethral retraction using anastomosis sutures as stay sutures (PURS) during robot-assisted radical prostatectomy. Sixty patients operated by a single surgeon were enrolled and data collected prospectively. This cohort was compared with another consecutive 60 patients operated with standard anastomosis. The new technique is based on preventing urethral retraction of the posterior urethra with two anastomosis sutures being used as stay sutures. The outcomes were prospectively followed and groups compared regarding early continence. International Consultation on Incontinence Questionnaire Short Form was used to assess incontinence and its impact on the quality of life. Pad use (yes or no pads) was evaluated as a more stringent criterion. Preoperative patient characteristics were similar between the two groups. Anastomosis was completed faster in PURS group (15.1 vs 18.5 min, p = 0.05). At postoperative week 1 and month 1, the severity and bother of incontinence were significantly less in the PURS group (12.7 vs 4.1 and 10.1 vs 2.6, p controlled studies would be required to further test the reproducibility of this technique.

  14. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  15. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  16. Mesh fixation with a barbed anchor suture results in significantly less strangulation of the abdominal wall.

    Science.gov (United States)

    Lyons, Calvin; Joseph, Rohan; Salas, Nilson; Reardon, Patrick R; Bass, Barbara L; Dunkin, Brian J

    2012-05-01

    Laparoscopic ventral hernia repair using an underlay mesh frequently requires suture fixation across the abdominal wall, which results in significant postoperative pain. This study investigates the utility of a novel mesh fixation technique to reduce the strangulation force on the abdominal wall. Multiple 2-cm(2) pieces of polyester mesh (Parietex Composite, Covidien) were placed as an underlay against a porcine abdominal wall. Fixation was accomplished using either the standard 0-polyglyconate or the 0-polyglyconate barbed anchor suture designed to hold in tissue without the need to tie a knot (V-Loc 180; Covidien). Suture fixation began with a stab wound incision in the skin. A suture-passing device then was used to pass the suture across the abdominal wall and through the mesh. The suture passer was removed and reintroduced through the same stab wound incision but at a different fascial entry point 1.5 cm away. The tail of the suture was grasped and pulled up through both the mesh and the abdominal wall, creating a full-thickness U-stitch. One tail of the suture was attached to a tensiometer, and the strangulation force on the abdominal wall was measured while the suture was tied (standard) or looped (barbed). To compare pullout force, the tensiometer was attached to either the mesh or the suture, and traction was applied until material failure or suture pull through. Results are expressed as mean ± standard deviation. Comparisons were performed using Student's t-test. Eight pieces of mesh were placed for each suture. The average force required to secure the barbed suture (0.59 ± 0.08 kg) was significantly less than the force needed to secure the standard suture (2.17 ± 0.58 kg) (P < 0.0001). Table 1 compares the suture pullout forces with the mesh failure forces. Although the pullout force for the standard suture is significantly greater than for the barbed suture, both sutures have a pullout strength significantly greater than the mesh failure force. Table

  17. Double chambered right ventricle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure.

  18. Double chambered right ventricle

    International Nuclear Information System (INIS)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung

    1983-01-01

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure

  19. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  20. Progressive posterior cortical dysfunction

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    Full Text Available Abstract Progressive posterior cortical dysfunction (PPCD is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal and ventral (occipito-temporal pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction, complete Balint's syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right . Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD.

  1. Positioning of the cross-stitch on the modified Kessler core tendon suture.

    Science.gov (United States)

    Gil-Santos, L; Monleón-Pradas, M; Gomar-Sancho, F; Más-Estellés, J

    2018-01-26

    Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral suture. An original mathematical model was employed to explain the mechanical behavior (strength, deformation, and distribution of load) of the different suture designs. The effect of the peripheral epitendinous suture, combined with the distance of the core suture, was evaluated. The variation of core suture distance had no relevant consequences on the overall resilience of the design. However, increasing the distance between the cross-stitches of the core suture reduces the deformation that is absorbed not only by the core suture itself but also by the peripheral suture. Adding a peripheral epitendinous suture to a 10-mm design almost doubles the breaking load in absolute values. The mathematical model predicts that the peripheral suture will support a greater load when the distance of the core suture cross-stitches is increased. The evidence level is II. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Endoscopic Management of Posterior Epistaxis

    OpenAIRE

    Paul, J.; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-01-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26–50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of ...

  3. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  4. Primary suture of amputation wound: pro et contra.

    Science.gov (United States)

    Muminagic, Sahib N

    2011-01-01

    During the First World War and the Second World War more than 80 % of wounded persons had injuries of upper or lower limbs. In the recent war in the Former Yugoslavia the percentage of persons with these injuries was above 80%. Each war is also characterized by the high percentage of wounded persons with amputations of upper or lower extremities. These amputations occurred mostly in the cases of polytrauma. In other cases we faced with severely wounded extremities with an extensive destruction of soft tissues, bones, blood vessels and joints, where the amputation is the only possible intervention to save the patient. In the previous World Wars, the surgeons have tried to shorten the time of treatment and to accept the surgical technique, by the application of primary suture of the wound. During the aggression on Bosnia and Herzegovina we were faced with a large number of wounded persons with amputations i.e. cases where we applied the primary suture. The results were still surprising and in many cases the wounds had primarily healed. The results were better when they were using primary suture on the upper extremities, measured at 61.9 % while the percentage of using the same suture on the lower limbs was of 48.8 %. The results of the war year 1995 were improved in comparison to the percentages listed above. The statistical analysis indicated that early application of the primary suture to the amputation wound was possible and largely successful, but, only when performed under certain conditions.

  5. EFFECTS OF DIFFERENT SUTURE MATERIALS ON TISSUE HEALING

    Directory of Open Access Journals (Sweden)

    Fırat SELVİ

    2016-01-01

    Full Text Available Purpose: The purpose of this study was to investigate the healing differences in between four different widely used suture materials in the oral surgery practice, including silk (Perma- Hand; Ethicon, INC., Somerville, NJ, USA, polypropylene (Prolene; Ethicon, INC., Somerville, NJ, USA, coated polyglactin 910 (Ethicon, INC., Somerville, NJ, USA. and polyglecaprone 25 (Ethicon, INC., Somerville, NJ, USA . Materials and Methods: 20 male rats were randomly allocated into two groups depending on their sacrification days (post-operative 1st and the 7th days. Four longitudinal incision wounds, each 1cm in size, were created on the dorsum of each animal which were then primarily closed with four different types of sutures. Results: The effects of these suture materials on soft tissue healing were compared histopathologically, by means of density of the cells, necrosis, fibrosis, foreign body reaction, the presence of cells of acute and chronic infection. No statistically significant difference was observed between the groups regarding the density of the cells, necrosis, fibrosis, foreign body reaction, and the presence of the cells of acute & chronic infections. Of note, propylene showed slightly less tissue reaction among the other materials. Conclusion: The results of our study showed that there is no only one ideal suture material for surgical practice. The factors related to the patient, the type of the surgery and the quality of the tissue are important to decide an appropriate suture material.

  6. A generalized mechanical model for suture interfaces of arbitrary geometry

    Science.gov (United States)

    Li, Yaning; Ortiz, Christine; Boyce, Mary C.

    2013-04-01

    Suture interfaces with a triangular wave form commonly found in nature have recently been shown to exhibit exceptional mechanical behavior, where geometric parameters such as amplitude, frequency, and hierarchy can be used to nonlinearly tailor and amplify mechanical properties. In this study, using the principle of complementary virtual work, we formulate a generalized, composite mechanical model for arbitrarily-shaped interdigitating suture interfaces in order to more broadly investigate the influence of wave-form geometry on load transmission, deformation mechanisms, anisotropy, and stiffness, strength, and toughness of the suture interface for tensile and shear loading conditions. The application of this suture interface model is exemplified for the case of the general trapezoidal wave-form. Expressions for the in-plane stiffness, strength and fracture toughness and failure mechanisms are derived as nonlinear functions of shape factor β (which characterizes the general trapezoidal shape as triangular, trapezoidal, rectangular or anti-trapezoidal), the wavelength/amplitude ratio, the interface width/wavelength ratio, and the stiffness and strength ratios of the skeletal/interfacial phases. These results provide guidelines for choosing and tailoring interface geometry to optimize the mechanical performance in resisting different loads. The presented model provides insights into the relation between the mechanical function and the morphological diversity of suture interface geometries observed in natural systems.

  7. Mechanical Behavior of Bio-inspired Model Suture Joints

    Science.gov (United States)

    Li, Yaning; Lin, Erica; Ortiz, Christine; Boyce, Mary

    2012-02-01

    Suture joints of varying degrees of geometric complexity are prevalent throughout nature as a means of joining structural elements while providing locally tailored mechanical performance. Here, micromechanical models of general trapezoidal waveforms of varying hierarchy are formulated to reveal the role of geometric complexity in governing stiffness, strength, toughness and corresponding deformation and failure mechanisms. Physical constructs of model composite suture systems are fabricated via multi-material 3D printing (Object Connex500). Tensile tests are conducted on samples covering a range in geometry, thus providing quantitative measures of stiffness, strength, and failure. The experiments include direct visualization of the deformation and failure mechanisms and their progression, as well as their dependence on suture geometry, showing the interplay between shear and tension/compression of the interfacial layers and tension of the skeletal teeth and the transition in failure modes with geometry. The results provide quantitative guidelines for the design and tailoring of suture geometry to achieve the desired mechanical properties and also facilitate understanding of suture growth and fusion, and evolutionary phenotype.

  8. 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification

    Directory of Open Access Journals (Sweden)

    Ying-Jie Lin

    2014-03-01

    Full Text Available AIM: To evaluate the efficacy and complications of 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification(PCO. METHODS: The 25G transconjunctival sutureless vitrectomy technique was performed in 48 cases(68 eyesof PCO eyes. The mean follow-up was 24mo. Best-corrected visual acuity(BCVA, intraocular pressure, anterior chamber reaction and complications during and after the operation were observed. RESULTS: 4mm diameter round holes were obtained at the center of the posterior capsule in all eyes. At 1d postoperative, uncorrected visual acuity(UCVAwas 0.70±0.12(0.5-1.0, and BCVA was 0.73±0.10(0.6-1.0. At 3mo postoperative, UCVA was 0.72±0.12(0.5-1.0, and BCVA was 0.74±0.10(0.6-1.0. It was statistical significance between preoperative and postoperative UCVA(t=-45.902, P=0.000. There were no complications during the postoperative follow-up period, such as dislocation or damage of the IOL, corneal edema, endoophthalmitis, pupil vitreous hernia, vitreous prolapse, retina detachment, intraocular hypertension and reocclusion of the visual axis, etc.CONCLUSION: The 25G transconjunctival sutureless vitrectomy technique to remove PCO is a safe and effective procedure with less complications, which can be an alternative treatment for PCO.

  9. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  10. Tensile strength of the pullout repair technique for the medial meniscus posterior root tear: a porcine study.

    Science.gov (United States)

    Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-10-01

    The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.

  11. Hand movements in laparoscopic suturing: a simple vector analysis.

    Science.gov (United States)

    Hansen, A J; Schlinkert, R T

    2005-03-01

    Laparoscopic suturing is a complex task that is vital to the performance of many advanced laparoscopic procedures. Mastery can be difficult and problematic for surgical trainees. We present a description of hand movements in laparoscopic suturing. Complex maneuvers are simplified into linear motions using vectors. The analysis is intended to be a tool for training in the art of laparoscopic surgery. Linear hand movements in the x and y axes produce opposite motions at the instrument tip. Position along the z axis influences the extent of hand movement relative to the instrument tip. Rotational movements of the hand produce an equal rotation of the instrument tip. Revolution is a complex motion that combines movements in x and y axes. Vector analysis reveals that the arc of revolution must be reversed to produce the desired needle motion. A conceptual understanding of hand-movement vectors facilitates the efficient mastery of the complex skills required for laparoscopic suturing.

  12. An absorbable thread suture technique to treat snoring.

    Science.gov (United States)

    Kwon, Jang-Woo; Kong, Tae-Hoon; Ha, Tae-Hyoung; Park, Dong-Joon

    2016-05-01

    We investigated a novel, minimally invasive surgery that uses an absorbable suture technique to treat snoring and mild obstructive sleep apnea. This simple procedure was developed to increase the stiffness of the soft palate and to promote uvula elevation with sutures. Thirty-five snorer and mild obstructive sleep apnea syndrome patients were included in this study. The palate was sutured with the newly developed technique. The results of our surgery were evaluated using polysomnography (PSG), the Epworth sleepiness scale (ESS), and a visual analogue scale (VAS) before surgery and 90 days after surgery. One year after surgery, telephone interviews were performed to assess patient satisfaction. Postoperative physical examinations of all patients showed increased stiffness of the soft palate and superiorly displaced uvula. These findings were consistent after the postoperative day 90. The patients' snoring symptoms and their bed partners' complaints, assessed by ESS and VAS, significantly improved compared to the pre-treatment value (p snoring and mild obstructive sleep apnea.

  13. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  14. Virtual interactive suturing for the Fundamentals of Laparoscopic Surgery (FLS).

    Science.gov (United States)

    Qi, Di; Panneerselvam, Karthikeyan; Ahn, Woojin; Arikatla, Venkata; Enquobahrie, Andinet; De, Suvranu

    2017-11-01

    Suturing with intracorporeal knot-tying is one of the five tasks of the Fundamentals of Laparoscopic Surgery (FLS), which is a pre-requisite for board certification in general surgery. This task involves placing a short suture through two marks in a penrose drain and then tying a double-throw knot followed by two single-throw knots using two needle graspers operated by both hands. A virtual basic laparoscopic skill trainer (VBLaST©) is being developed to represent the virtual versions of the FLS tasks, including automated, real time performance measurement and feedback. In this paper, we present the development of a VBLaST suturing simulator (VBLaST-SS©). Developing such a simulator involves solving multiple challenges associated with fast collision detection, response and force feedback. In this paper, we present a novel projection-intersection based knot detection method, which can identify the validity of different types of knots at haptic update rates. A simple and robust edge-edge based collision detection algorithm is introduced to support interactive knot tying and needle insertion operations. A bimanual hardware interface integrates actual surgical instruments with haptic devices enabling not only interactive rendering of force feedback but also realistic sensation of needle grasping, which realizes an immersive surgical suturing environment. Experiments on performing the FLS intracorporeal suturing task show that the simulator is able to run on a standard personal computer at interactive rates. VBLaST-SS© is a computer-based interactive virtual simulation system for FLS intracorporeal knot-tying suturing task that can provide real-time objective assessment for the user's performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Triclosan sutures for surgical site infection in colorectal cancer.

    Science.gov (United States)

    Yamashita, Kanefumi; Takeno, Shinsuke; Hoshino, Seiichiro; Shiwaku, Hironari; Aisu, Naoya; Yoshida, Yoichiro; Tanimura, Syu; Yamashita, Yuichi

    2016-11-01

    Among all procedures, surgical site infections (SSIs) in colorectal surgery continue to have the highest rate, accounting for 5%-45%. To prevent the bacterial colonization of suture material, which disables local mechanisms of wound decontamination, triclosan-coated sutures were developed. We assessed the effectiveness of triclosan-coated sutures used for skin closure on the rate of SSIs in colorectal cancer surgery. Until August 2012, we used conventional methods for skin closure in colorectal cancer surgery at the Department of Gastroenterological Surgery, Fukuoka University Faculty of Medicine. Therefore, for the control group, we retrospectively collected surveillance data over a 1.5-y period. From September 2012, we began using triclosan-coated polydioxanone antimicrobial sutures (PDS plus) for skin and fascia closure. Hence, we collected data for the study group from September 2012 to October 2013. Differences in baseline characteristics and selection bias were adjusted using the propensity score-matching method. A total of 399 patients who underwent colorectal surgery were included in this study. There were 214 patients in the control group and 185 patients in the study group. Baseline patient characteristics were similar between the propensity score-matched groups. The incidence of SSIs was less in the study group. Multivariate logistic regression analysis showed that the site of the procedure, laparoscopic surgery, and using triclosan-coated sutures remained the independent predictors of SSIs. The use of triclosan-coated sutures was advantageous for decreasing the risk of SSIs after colorectal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. EVALUATION OF ADJUSTABLE SUTURE TECHNIQUE IN OUTCOME OF PTOSIS SURGERY

    Directory of Open Access Journals (Sweden)

    Nagaraju

    2015-10-01

    Full Text Available AIM: To evaluate the outcome of adjustable suture technique in ptosis surgery. INTRODUCTION : Surgical management of blepharoptosis is indicated in multiple situations and the post - operative outcomes can be as variable as the indications for surgery. Adjustable suture techniques in ptosis repair have been introduced and variable efficacies have been reported. MATERIALS AND METHODS: A retrospective case review of medical records from June 2010 to May 2011 (12 months of 5 eyes of 5 consecutive patients operated by a single surgeon at a Tertiary Eye care center in South India were reviewed. The clinical profile of patients included was r ecorded and results of adjustable suture technique described by Borman and collegues for these patients was reported. RESULTS: 5 eyes of 5 patients underwent adjustable suture ptosis repair in the study duration. 4 patients with moderate and 1 with severe ptosis, all having good levator function were diagnosed to have c ongenital ptosis in 3 cases and a cquired involutional ptosis in 2 cases. All 5 cases had a satisfactory outcome at day 4 post - operative after adjustment of lid height in the out - patient clini c. 1 patient with acquired involutional ptosis, identified with levator dehiscence intra - operatively had overcorrection at 6 months warranting re - surgery while the other 4 patients had satisfactory cosmetic lid height and functional outcome at 6 months fol low up after the adjustable suture technique for ptosis repair. CONCLUSION: Use of adjustable sutures in ptosis surgery can eliminate the intraoperative lid factors that can lead to unpredictable results. The technique described is easy to adapt and perfor m and can give repeatable and well acceptable results in the properly selected cases

  17. Force Comparison of Commercially Available Transfascial Suture Passers.

    Science.gov (United States)

    Shope, Alexander J; Winder, Joshua S; Bliggenstorfer, Jonathan T; Crowell, Kristen T; Haluck, Randy S; Pauli, Eric M

    2017-06-01

    Transfascial suture passers (TSPs) are a commonly used surgical tool available in a wide array of tip configurations. We assessed the insertion force of various TSPs in an ex vivo porcine model. Uniform sections of porcine abdominal wall were secured to a 3D-printed platform. Nine TSPs were passed through the abdominal wall both without and with prolene suture under the following scenarios: abdominal wall only and abdominal wall plus underlay ePTFE or composite ePTFE/polypropylene mesh. Insertion forces were recorded in Newton (N). When passed without suture through the abdominal wall, smaller diameter TSPs required less insertional force (1.50 ± 0.17 N vs 9.68 ± 1.50 N [ P = 0.00072]). Through composite mesh, the solid tipped TSPs required less force than hollow tipped ones (3.87 ± 0.25 N vs 7.88 ± 0.20 N [ P = 0.00026]). Overall, smaller diameter TSPs required less force than the larger TSPs when passed through ePTFE empty (Gore 2.95 ± 0.83 N vs Carter-Thomason 16.07 ± 2.10 N [ P = .0005]) or with suture (Gore 8.37 ± 2.59 N vs Carter-Thomason 19.12 ± 1.10 N [ P = .003]). Diameter plays the greatest role in the force required for TSP penetration. However, when passed through underlay mesh or while holding suture, distal tip shape, the mechanism of suture holding, and shaft diameter all contribute to the forces necessary for penetration. These factors should be considered when choosing a TSP for intraoperative use.

  18. Hidroma subdural na fossa posterior

    Directory of Open Access Journals (Sweden)

    José Carlos Vasques

    1970-03-01

    Full Text Available Os autores relatam um caso de hidroma subdural na fossa craniana posterior conseqüente a traumatismo na região occipital. O paciente foi operado com pleno sucesso. A raridade da localização de hidroma na fossa posterior é salientada, sendo discutidos os possíveis mecanismos etio-patogênicos.

  19. Effect of robotic manipulation on unidirectional barbed suture integrity: evaluation of tensile strength and sliding force.

    Science.gov (United States)

    Kaushik, Dharam; Clay, Kevin; Hossain, S G M; Park, Eugene; Nelson, Carl A; LaGrange, Chad A

    2012-06-01

    One of the more challenging portions of robot-assisted radical prostatectomy (RARP) is the urethrovesical anastomosis. Because of this, a unidirectional absorbable barbed suture (V-Loc(™)) has been used to complete the anastomosis with better efficiency and less tension. The effect of robotic needle driver manipulation on barbed suture is unknown. Therefore, the aim of this study is to determine whether robotic manipulation decreases the tensile strength and peak sliding force of V-Loc barbed suture. Fifty-six V-Loc sutures were compared with 56 Maxon sutures. All sutures were 3-0 caliber. Half of the sutures in each group were manipulated with a da Vinci(®) robot large needle driver five times over a 5 cm length of suture. The other half was not manipulated. Breaking force was determined by placing sutures in a Bose ElectroForce load testing device. For sliding force testing, 28 V-Loc sutures were manipulated in the same fashion and compared with 28 nonmanipulated V-Loc sutures. Peak force needed to make the suture slip backward in porcine small intestine was determined to be the sliding force. Scanning electron microscopy of the barbs before and after robotic manipulation was also performed. The mean difference in breaking forces for manipulated vs nonmanipulated Maxon sutures was 4.52 N (P=0.004). The mean difference in breaking forces for manipulated vs nonmanipulated V-Loc sutures was 1.30 N (P=0.046). The manipulated V-Loc group demonstrated a lower peak sliding force compared with the nonmanipulated group (0.76 vs 0.88 N, P=0.199). Electron microscopy revealed minor structural damage to the barbs and suture. Tensile strength and peak sliding force of V-Loc suture is decreased by robotic manipulation. This is likely because of structural damage to the suture and barbs. This structural damage, however, is likely not clinically significant.

  20. The Stress Relaxation Process in Sutures Tied with a Surgeon's Knot in a Simulated Biological Environment.

    Science.gov (United States)

    Liber-Kneć, Aneta; Łagan, Sylwia

    2016-01-01

    The exact characteristics of sutures are not only the basis for selecting from among different types of suture, but also provide the necessary information for the design of new surgical sutures. Apart from information relating to the breaking load of a suture reported in pharmacopoeias, the viscoelastic properties of sutures can be an additional selection criterium - one that influences stitching quality, especially when there is a risk of wound dehiscence. The aim of the study was to assess the stress relaxation process for 3 polymeric sutures in an environment simulating the conditions in a living organism and (for comparison) in room conditions. Stress relaxation testing was carried out on 3 polymeric sutures: polypropylene (PP), polydioxanone (PDS) and polyglycolic acid (PGA). To identify the mechanical properties of the sutures, uniaxial tensile tests were conducted according to the Polish Pharmacopoeia. The relaxation test was carried out in room conditions and in the bath simulating a biological environment. The sutures being tested were tied with a surgeon's knot. The PP suture exhibited the greatest stress relaxation (18% of the initial stress in room conditions and 21% of the initial stress in the bath). The PGA suture exhibited the least stress relaxation (approximately 60% of the initial stress in room conditions and 59% of the initial stress in the bath). The PDS suture was tested at a lower strain level and showed stress relaxation similar to the PGA suture (approximately 63% of the initial stress in room conditions and 55% in the bath). Multifilament braided absorbable (PGA) sutures and monofilament absorbable (PDS) sutures had a higher stress relaxation ratio over time than monofilament non-absorbable (PP) sutures. These findings may indicate higher stress maintained over time in PDS and PGA sutures, and thus higher tension at wound edges, sufficient to resist wound dehiscence.

  1. Interrupted or continuous-intradermal suturing? Statistical analysis of postoperative scars

    Directory of Open Access Journals (Sweden)

    Elif Sarı

    2014-12-01

    Full Text Available Background and Design: Postoperative scar development is an important problem for patients treated in plastic surgery clinics. Most patients think that continuous intradermal suturing is superior to interrupted suturing because they assume that it creates less scarring. We evaluated scars that form following intradermal and interrupted suturing. This article presents our controlled study that objectively compared the scars on patients' faces using a wound evaluation scale. Materials and Methods: Thirty-five patients, who had undergone operations on the bilateral cheeks, were included in this study. Thirty patients were female; five patients were male. Their mean age was 40.05 years. The average scar evaluation time after surgery was 9.05 months. Elliptical excisions were made on the lesions under local anesthesia. The incisions on the right cheeks were sutured with 6/0 monofilament nonabsorbable sutures using the continuous intradermal suturing technique. The left cheek incisions were sutured with same sutures using the interrupted suturing method. Results: The patients were evaluated 7–11 months after operation (mean: 9.05 months using the Stony Brook Scar Evaluation Scale. A Related Samples T-test was used for statistical evaluation of the differences between the suturing techniques. No significant differences were noted in scar formation between the two suturing methods (p>0.05. Conclusion: We found no differences in scar formation between the two frequently used suturing techniques studied here. We believe that the suturing technique is a less important determinant of scar formation than are other factors.

  2. Space plasma simulation chamber

    International Nuclear Information System (INIS)

    1986-01-01

    Scientific results of experiments and tests of instruments performed with the Space Plasma Simulation Chamber and its facility are reviewed in the following six categories. 1. Tests of instruments on board rockets, satellites and balloons. 2. Plasma wave experiments. 3. Measurements of plasma particles. 4. Optical measurements. 5. Plasma production. 6. Space plasms simulations. This facility has been managed under Laboratory Space Plasma Comittee since 1969 and used by scientists in cooperative programs with universities and institutes all over country. A list of publications is attached. (author)

  3. Stability of Streamer Chamber

    Science.gov (United States)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi

    1982-08-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result.

  4. Stability of streamer chamber

    International Nuclear Information System (INIS)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi.

    1982-01-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result. (author)

  5. A reusable suture anchor for arthroscopy psychomotor skills training.

    Science.gov (United States)

    Tillett, Edward D; Rogers, Rainie; Nyland, John

    2003-03-01

    For residents to adequately develop the early arthroscopy psychomotor skills required to better learn how to manage the improvisational situations they will encounter during actual patient cases, they need to experience sufficient practice repetitions within a contextually relevant environment. Unfortunately, the cost of suture anchors can be a practice repetition-limiting factor in learning arthroscopic knot-tying techniques. We describe a technique for creating inexpensive reusable suture anchors and provide an example of their application to repair the anterior glenoid labrum during an arthroscopy psychomotor skills laboratory training session.

  6. Synchrotron-microcomputed tomography studies of normal and pathological cranial sutures: further insight.

    Science.gov (United States)

    Regelsberger, Jan; Schmidt, Tobias; Busse, Björn; Herzen, Julia; Tsokos, Michael; Amling, Michael; Beckmann, Felix

    2010-03-01

    Both CT and high-frequency ultrasound have been shown to be reliable diagnostic tools used to differentiate normal cranial sutures from suture synostosis. In nonsynostotic plagiocephaly, overlapping of the bony plates and the so-called "sticky suture" is still controversial and is believed to represent a pathological fusion process. Synchrotron-microcomputed tomography (SRmCT) studies were undertaken to determine whether positional head deformities can be assumed to be true suture pathologies. Morphological features and growth development of 6 normal cranial sutures between the ages of 3 and 12 months were analyzed histologically. Additionally 6 pathological sutures, including sagittal synostosis and nonsynostotic plagiocephaly (NSP), were compared with the group of normal sutures by histological and SRmCT studies. Synchrotron-microcomputed tomography is a special synchrotron radiation source with a high photon flux providing a monochromatic x-ray beam with a very high spatial resolution. Morphological characteristics of the different suture types were evaluated and bone density alongside the sutures was measured to compare the osseous structure of the adjacent bony plates of normal and pathological sutures. Histologically jointlike osseous edges of the normal sutures were seen in the 1st month of life and interlocking at the age of approximately 12 months. During this 1st year, bone thickness increases and suture width decreases. The SRmCT studies showed that: 1) sutures and adjacent bones in NSP are comparable to normal sutures in terms of their morphological aspects; 2) bone densities in the adjacent bony plates of NSP and normal sutures are not different; 3) thickening of the diploe with ridging of the bone in sagittal synostosis is associated with significantly higher bone density; 4) synostotic sutures are only partially fused but vary in their extent; and 5) nonfused sections in sagittal synostosis behave like normal sutures without any signs of pathological

  7. Posterior Scar Brachioplasty with Fascial Suspension: A Long-term Follow-up of a Modified Technique

    Directory of Open Access Journals (Sweden)

    Hamdy Elkhatib, MD

    2013-09-01

    Conclusions: The current posterior scar maneuver with fascial suspension prevented the tension on the suture line and consequently prevented the widening of the scar and facilitated the modeling procedure by removing the appropriate amount of skin and subcutaneous tissues. It creates a low-lying, posterior, well-hidden scar when viewed from the patient’s front or patient’s lateral. The scar is partially (upper third visible when viewed from patient’s back. The technique is avoiding injury to the sensory and motor nerves of the arm and decreases the insult to the lymphatic.

  8. through the posterior tympanotomy

    Directory of Open Access Journals (Sweden)

    Emilia B. Karchier

    2016-07-01

    Full Text Available Introduction : The anterior epitympanum recess (AER is a common place of the development of the cholesteatoma, which is why removal of the matrix from this area plays a key role in the surgical treatment of chronic otitis media. Aim : To evaluate the intraoperative visibility of AER in endoscopic optics in comparison to microscopic optics and to determine the prevalence of cholesteatoma in various types of construction of the AER. Study design: Retrospective analysis of intraoperative search. Material and methods : The study included 55 patients treated in the Department of Otolaryngology, Medical University of Warsaw within the years 2009–2011, who underwent endoscopy-assisted canal wall up tympanoplasty with posterior tympanotomy. The type of construction of the AER – cellular or dome-shaped – was determined. Results : Cellular type of recess was found intraoperatively in 32% of ears and dome-shaped in 68% of the study group. The population with chronic otitis media does not differ significantly compared to the general population in terms of the construction of the anterior epitympanum recess (p = 0.668108; χ 2 = 0.1838235, df = 1. Among the ears with cholesteatoma a cellular AER was found in 48.3% of cases and a dome-shaped AER was found in 51.7%. Conclusions : The cellular type of AER was significantly more frequent in ears with cholesteatoma (p < 0.01, χ 2 = 29.86492, df = 1. Level of evidence: 1b.

  9. Absorbable Polydioxanone (PDS) suture provides fewer wound complications than polyester (ethibond) suture in acute Tendo-Achilles rupture repair

    LENUS (Irish Health Repository)

    Baig, M N

    2017-05-01

    We prospectively studied acute Achilles tendon rupture in patients over a two 2-year period and reviewed the causes, outcome and complications. There were 53 patients included with acute Achilles rupture with minimum follow up period of 6 months. We compared the outcomes including infection rate and Boyden score between the two groups repaired by Polydioxanone and Polyester respectively. All infected cases had a suture repair using the polyester suture. The difference in the infection rate was highly significant between the 2 groups (p=0.001). All 34 patients (100%) in the PDS group had good \\/ excellent results based on the Boyden clinical assessment. Conversely, only 16 patients 9(68.4%) had good or excellent results IN Polyester repair group. Patients treated with a non- absorbable suture (ethibond) material for repair had a higher incidence infection and worse Boyden scores than the absorbable PDS group.

  10. Council Chamber exhibition

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    To complete the revamp of CERN’s Council Chamber, a new exhibition is being installed just in time for the June Council meetings.   Panels will showcase highlights of CERN’s history, using some of the content prepared for the exhibitions marking 50 years of the PS, which were displayed in the main building last November. The previous photo exhibition in the Council Chamber stopped at the 1970s. To avoid the new panels becoming quickly out of date, photos are grouped together around specific infrastructures, rather than following a classic time-line. “We have put the focus on the accelerators – the world-class facilities that CERN has been offering researchers over the years, from the well-known large colliders to the lesser-known smaller facilities,” says Emma Sanders, who worked on the content. The new exhibition will be featured in a future issue of the Bulletin with photos and an interview with Fabienne Marcastel, designer of the exhibit...

  11. Time projection chamber

    International Nuclear Information System (INIS)

    Kamae, Tsuneyoshi

    1984-01-01

    A time projection chamber (TPC) was developed at Lawrence Berkeley Laboratory to compensate the shortcoming of drift chambers. The characteristics of the TPC are the improvement of the distortion of the trace of particles in long drift, the improvement of particle identification by taking out the analog signal proportional to the number of electrons, and the improvement of the method to analyze the three-dimensional analog signal. Two large TPC's are designed and manufactured in Japan. The details of these TPC's are explained in this paper. The results of test experiment are as follows. The accuracy of the measurement of particle position was about 100 micrometer in the r-theta plane and about 340 micrometer in the Z-direction. The accuracy of the measurement of ionization loss (dE/dx) was less than 4.0 percent. The reconstruction of quark pair production can be made. At present, the identification of K-mesons in jet phenomena is possible, and the cross-sections of inclusive processes are easily obtained. (Kato, T.)

  12. Achondroplasia with multiple-suture craniosynostosis: a report of a new case of this rare association

    NARCIS (Netherlands)

    Bessenyei, Beáta; Nagy, Andrea; Balogh, Erzsébet; Novák, László; Bognár, László; Knegt, Alida C.; Oláh, Eva

    2013-01-01

    We report on a female patient with an exceedingly rare combination of achondroplasia and multiple-suture craniosynostosis. Besides the specific features of achondroplasia, synostosis of the metopic, coronal, lambdoid, and squamosal sutures was found. Series of neurosurgical interventions were

  13. Michigan ATLAS MDT Chamber Mass Production

    CERN Document Server

    Diehl, E; Levin, D; McKee, S; Neal, H; Schick, H; Tarle, G; Thun, R; Weaverdyck, C; Xu, Q; Zhao, Z; Zhou, B

    2001-01-01

    This paper describes the ATLAS MDT precision muon chamber construction at the University of Michigan. The chamber assembly facilities, the jigging set up, alignment procedures, and other measurements necessary for chamber assembly are described. The chamber quality assurance monitoring procedures and data for the first year mass production are presented. The chamber gas system assembly facilities, and the chamber leak test procedure together with data also reported. The chamber production database, which monitors chamber production, is also discussed.

  14. Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair.

    Science.gov (United States)

    Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J; Heard, Wendell M R; Savoie, Felix H; You, Zongbing

    2014-07-01

    The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord(™) suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire(®) suture (FiberWire(®), Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord(™) suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire(®) suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord(™) and FiberWire(®) sutures (P = 0.026), but not significant between Orthocord(™) and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire(®) sutures (P = 0.103). The cheese-wiring effect is less in the Orthocord(™) suture than in the FiberWire(®) suture in human cadaveric supraspinatus tendons. Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection.

  15. Polymeric Medical Sutures: An Exploration of Polymers and Green Chemistry

    Science.gov (United States)

    Knutson, Cassandra M.; Schneiderman, Deborah K.; Yu, Ming; Javner, Cassidy H.; Distefano, Mark D.; Wissinger, Jane E.

    2017-01-01

    With new K-12 national science standards emerging, there is an increased need for experiments that integrate engineering into the context of society. Here we describe a chemistry experiment that combines science and engineering principles while introducing basic polymer and green chemistry concepts. Using medical sutures as a platform for…

  16. Probing electrical conductivity of the Trans-European Suture Zone

    Czech Academy of Sciences Publication Activity Database

    Brasse, H.; Červ, Václav; Ernst, T.; Hoffmann, N.; Jankowski, J.; Józwiak, W.; Korja, T.; Kreutzmann, A.; Neska, A.; Palshin, N.; Pedersen, L. B.; Schwarz, G.; Smirnov, M.; Sokolova, E.; Varentsov, I. M.

    2006-01-01

    Roč. 87, č. 29 (2006), 281, 287 ISSN 0096-3941 R&D Projects: GA ČR GA205/04/0740 Institutional research plan: CEZ:AV0Z30120515 Keywords : electrical conductivity * Trans-European Suture Zone * EMTESZ-Pomerania Subject RIV: DE - Earth Magnetism, Geodesy, Geography

  17. Comparative study between purse–string suture and peritoneal ...

    African Journals Online (AJOL)

    Comparative study between purse–string suture and peritoneal disconnection with ligation techniques in the laparoscopic repair of inguinal hernia in infants and ... The main outcome measurement was recurrence, and secondary outcome measurements were operative time, hospital stay, intraoperative complications, ...

  18. Sterilization effects on tensile strength of non-conventional suture ...

    African Journals Online (AJOL)

    An experiment was carried out to determine the tensile strength of embroidery, braiding, cobbler's thread and nylon mono-filament fishing line (NMFL) use as non-conventional suture material. Their tensile strength were determined pre- sterilization using various calibrated weights (50gm, 100gm, 500gm).

  19. Outcome of Strabismus Surgery by Nonadjustable Suture among ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... Outcome of strabismus surgery by nonadjustable suture among adults attending a university hospital of. Saudi Arabia. Niger J Clin Pract 2017;20:335-40. This is an open access article distributed under the terms of the Creative Commons. Attribution-Non Commercial-Share Alike 3.0 License, which allows ...

  20. Outcome of strabismus surgery by nonadjustable suture among ...

    African Journals Online (AJOL)

    Objective: To describe the outcome and safety of surgical treatment of Saudi adult patients with strabismus by nonadjustable suture and to evaluate the prevalence of diplopia and binocularity after strabismus correction. Materials and Methods: Retrospective analysis of medical records of 96 patients above the age of ...

  1. Penile torsion correction by diagonal corporal plication sutures

    Directory of Open Access Journals (Sweden)

    Brent W. Snow

    2009-02-01

    Full Text Available Penile torsion is commonly encountered. It can be caused by skin and dartos adherence or Buck’s fascia attachments. The authors suggest a new surgical approach to solve both problems. If Buck’s fascia involvement is demonstrated by artificial erection then a new diagonal corporal plication suture is described to effectively solve this problem.

  2. Omental pedicle transposition and suture repair of peripheral nerve ...

    African Journals Online (AJOL)

    Abu wael

    immediately under a dissecting microscope (Kruss, Germany). Six equidistant epineurial simple interrupted sutures were ... strong, and muscle mass atrophy graded as severe, moderate, mild or normal. Sensory functions evaluation .... could secrete analgesic substances such as opioids, neurotransmitters including gamma ...

  3. non absorbable sutures in the urinary bladder resulting

    African Journals Online (AJOL)

    The vesical calculus. Urol Clin North AM. 2000, 27:333-346. 3. Evans JW, Chapple CR, Ralph DJ, Millory EJ: Bladder calculus formation as a complication of the Stamey procedure. Br J Urol 1990,. 65:580-582. 4. Sheng-Tsun Su, He-Fu Haung, Shu-Fen. Chang. Encrusted Bladder stone on Non- absorbable sutures after a ...

  4. Stress-Softening and Residual Strain Effects in Suture Materials

    Directory of Open Access Journals (Sweden)

    Alex Elías-Zúñiga

    2013-01-01

    Full Text Available This work focuses on the experimental characterization of suture material samples of MonoPlus, Monosyn, polyglycolic acid, polydioxanone 2–0, polydioxanone 4–0, poly(glycolide-co-epsilon-caprolactone, nylon, and polypropylene when subjected to cyclic loading and unloading conditions. It is found that all tested suture materials exhibit stress-softening and residual strain effects related to the microstructural material damage upon deformation from the natural, undistorted state of the virgin suture material. To predict experimental observations, a new constitutive material model that takes into account stress-softening and residual strain effects is developed. The basis of this model is the inclusion of a phenomenological nonmonotonous softening function that depends on the strain intensity between loading and unloading cycles. The theory is illustrated by modifying the non-Gaussian average-stretch, full-network model to capture stress-softening and residual strains by using pseudoelasticity concepts. It is shown that results obtained from theoretical simulations compare well with suture material experimental data.

  5. Healing of the suture line in the irradiated small intestine

    International Nuclear Information System (INIS)

    Da Costa, S.A.

    1989-01-01

    With the help of data from literature the author goes more deeply into the aetiology, treatment and possible prevention of lesions of the small intestine related to preceding irradiation. In a clinical retrospective study at twenty patients who, after irradiation of the abdominal and pelvic areas, have been submitted to abdominal surgery, the relation is studied between predistion factors for gastrointestinal complications after irradiation, the surgeries applied in case of small-intestine problems and postoperative complications. The third part of the thesis covers an experimental part in which the healing process of suture line in the terminal ileum has been studied after resection and reanastomosis in previously irradiated bowel of the rat. It was investigated whether differences occurred in the healing process of suture line after various periods - 4, 10 and 40 weeks, after irradiation. Also comparison took place with a control group which underwent a similar procedure with the exception of the radiation treatment, which was simulated in this group. In a second experiment it was investigated if the healing process of suture line depends on the type of anastomosis. An end-to-end anastomosis was chosen versus side-to-side anastomosis. Also in this experiment an irradiated group was compared with a control group. Furthermore a method was developed for performing micro-angiographies of the rat intestine in order to demonstrate obliteration of blood vessels in irradiated intestine and to assess neovascularization in the intestinal wall at the suture line. (author). 84 refs.; 18 figs.; 27 tabs

  6. Comparison of Subcuticular Suture Materials in Cesarean Skin Closure

    Directory of Open Access Journals (Sweden)

    Pınar Solmaz Hasdemir

    2015-01-01

    Full Text Available Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure.

  7. Punctal Occlusion with Prolene Suture Material in the Patients with ...

    African Journals Online (AJOL)

    polypropene, a synthetic linear polyolefin. This suture is pigment blue to enhance visibility. Prolene is neither absorbable nor elastic [Figure 9]. The size (such as the diameter of the cross-section and the thickness) of the Prolene material as measured with an optical microscope (Nikon Eclipse Me600) and a digital calliper.

  8. Classification of posterior vitreous detachment

    Science.gov (United States)

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2014-01-01

    Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography (OCT). By biomicroscopy, the vitreous condition is determined based on the presence or absence of a PVD. The PVD then is classified as either a complete posterior vitreous detachment (C-PVD) or a partial posterior vitreous detachment (P-PVD). A C-PVD is further divided into a C-PVD with collapse and a C-PVD without collapse, while a P-PVD is divided into a P-PVD with shrinkage of the posterior hyaloid membrane (P-PVD with shrinkage) and a P-PVD without shrinkage of the posterior hyaloid membrane (P-PVD without shrinkage). A P-PVD without shrinkage has a subtype characterized by vitreous gel attachment through the premacular hole in a posterior hyaloid membrane to the macula (P-PVD without shrinkage [M]). By OCT, a shallow PVD is classified as the absence of a shallow PVD or as a shallow PVD. A shallow PVD is then subclassified as a shallow PVD without shrinkage of the posterior vitreous cortex, a shallow PVD with shrinkage of the posterior vitreous cortex, and a peripheral shallow PVD. A shallow PVD without shrinkage of the posterior vitreous cortex has two subtypes: an age-related shallow PVD and a perifoveal PVD associated with a macular hole. PMID:24376338

  9. Nonsuturing or Skin Adhesives versus Suturing of the Perineal Skin After Childbirth: A Systematic Review

    NARCIS (Netherlands)

    Seijmonsbergen-Schermers, A.E.; Sahami, S.; Lucas, C.; de Jonge, A.

    2015-01-01

    Background: Suturing of perineal trauma after childbirth can cause problems such as pain, discomfort because of tight sutures, the need for suture removal, and dyspareunia. It is unclear whether leaving the perineal skin unsutured or using skin adhesives might prevent these problems. Methods:

  10. Nonsuturing or Skin Adhesives versus Suturing of the Perineal Skin After Childbirth: A Systematic Review

    NARCIS (Netherlands)

    Seijmonsbergen-Schermers, Anna E.; Sahami, Saloomeh; Lucas, Cees; Jonge, Ank de

    2015-01-01

    Suturing of perineal trauma after childbirth can cause problems such as pain, discomfort because of tight sutures, the need for suture removal, and dyspareunia. It is unclear whether leaving the perineal skin unsutured or using skin adhesives might prevent these problems. CENTRAL, MEDLINE, EMBASE,

  11. REACTION OF THE RABBIT CORNEAL ENDOTHELIUM TO NYLON SUTURES - A SEM STUDY

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; RIJNEVELD, WJ; HOUTMAN, WA; WORST, JGF

    1990-01-01

    Nylon and stainless steel sutures separately placed deeply into rabbit corneas by splitting the stroma for a few millimeters, without closing sutures, remained in the cornea for two, four and six weeks respectively. In contrast to the stainless steel sutures an extensive tissue reaction could be

  12. Microbial adherence on various intraoral suture materials in patients undergoing dental surgery.

    Science.gov (United States)

    Banche, Giuliana; Roana, Janira; Mandras, Narcisa; Amasio, Mario; Gallesio, Cesare; Allizond, Valeria; Angeretti, Alessandra; Tullio, Vivian; Cuffini, Anna Maria

    2007-08-01

    Sutures used in oral surgery should avoid or limit bacterial adhesion and proliferation to those parts exposed to oral fluids. Hence, microbial colonization on various intraoral suture materials from patients undergoing dental surgery was compared. During dentoalveolar surgery, various suture materials were used in 60 patients, who were randomly divided into 5 groups of 12. In each group, silk was placed intraorally in association with a different type of suture (ie, Supramid, Synthofil, Ethibond Excel, Ti-cron, Monocryl) at the same site to compare microbial colonization intraindividually. Eight days postoperatively, the sutures were removed, and adhered micro-organisms were isolated, counted, and identified through enzymatic activities and fermentation of sugars. In all 60 patients, silk sutures exhibited the smallest affinity toward the adhesion of bacteria compared with considerable proliferation with nonresorbable multifilament sutures (Supramid, Synthofil, Ethibond Excel, Ti-cron). On the contrary, the microbial load was significantly lower when absorbable monofilament Monocryl was used. A greater quantity of bacteria was found on nonresorbable sutures than on absorbable ones, and nearly 2 times more facultative anaerobic bacteria were isolated in total. Our results show that bacteria adhere with different affinity to various types of suture materials. Absorbable silk and Monocryl exhibited the smallest number of adherent bacteria. Colonization by pathogens on sutures leads to the recommendation that sutures should be removed as early as possible after surgery is performed, to eliminate or to limit the reservoir for oral pathogens. This recommendation is dependent on whether the suture is absorbable.

  13. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  14. Diogene pictorial drift chamber

    International Nuclear Information System (INIS)

    Gosset, J.

    1984-01-01

    A pictorial drift chamber, called DIOGENE, has been installed at Saturne in order to study central collisions of high energy heavy ions. It has been adapted from the JADE internal detector, with two major differences to be taken into account. First, the center-of-mass of these collisions is not identical to the laboratory reference frame. Second, the energy loss and the momentum ranges of the particles to be detected are different from the ones in JADE. It was also tried to keep the cost as small as possible, hence the choice of minimum size and minimum number of sensitive wires. Moreover the wire planes are shifted from the beam axis: this trick helps very much to quickly reject the bad tracks caused by the ambiguity of measuring drift distances (positive or negative) through times (always positive)

  15. How much do we need experts during laparoscopic suturing training?

    Science.gov (United States)

    Van Bruwaene, Siska; De Win, Gunter; Miserez, Marc

    2009-12-01

    Because of the complex nature of laparoscopic suturing, numerous curricula have been developed to overcome the steep learning curve in a patient-free environment. Distributed training leads to better acquisition and retention of skill compared with massed training. However, this requires considerable time commitment of experts that supervise these training sessions. This study investigates the possibility of replacing expert supervision by structured training with video demonstrations and peer feedback. The study population consisted of two balanced groups of ten senior medical students with minimal experience in laparoscopy. The control group trained with continuous expert feedback while for the experimental group only video demonstrations and external feedback from peers were available. Training was completed when a previously determined expert level was achieved on two consecutive attempts (proficiency criterion). Students were tested on their suturing skills 1 week after the training as well as after 4 months. A composite score assessing quality and quantity of suturing performance was used. Data are shown as median (interquartile range, IQR). Students' performance improved more than 200% after training. Learning curves did not differ between groups (p = 0.28). One week after training, scores were 192 s (IQR 65 s) for the control and 190 s (IQR 27 s) for the experimental group (p = 0.63). After 4 months this was 223 s (IQR 88 s) and 220 s (IQR 37 s), respectively (p = 0.60). Both training methods are very efficient at improving laparoscopic suturing skills and provide excellent skill retention. We therefore conclude that structured training with video demonstrations and peer feedback can replace expert supervision to teach laparoscopic suturing skills to novices. This will facilitate practical organization of skills training.

  16. Transvaginal bladder neck closure with posterior urethral flap for devastated urethra.

    Science.gov (United States)

    Rovner, Eric S; Goudelocke, Colin M; Gilchrist, Alienor; Lebed, Brett

    2011-07-01

    To present a modified transvaginal bladder neck closure (TV BNC) technique using a posterior urethral flap to minimize the potential risk of ureteral injury and fistula formation. Urethral and bladder neck destruction owing to chronic indwelling urethral catheters in female neurogenic patients is a devastating complication. A retrospective review was performed of all patients undergoing TV BNC at a single institution during a 3-year period. All patients had had a nonfunctional or destroyed urethra because of a long-term indwelling urethral catheter. In brief, the devastated outlet was closed using the dorsally bivalved urethra as a flap that was rotated cephalad onto the incised anterior bladder wall for closure, thereby rotating the suture line high into the retropubic space. A postoperative cystogram was obtained at 2-3 weeks. A total of 11 consecutive female patients with a devastated outlet underwent TV BNC, as described, with placement of a suprapubic tube. One patient experienced failure at 6 weeks postoperatively. The mean follow-up for the entire cohort was 9.6 months (range 1-36). Serial upper tract imaging at the last follow-up visit revealed no new hydroureteronephrosis. The results of our study have shown that TV BNC with a posterior urethral flap provides satisfactory early results. This technique creates a suture line far removed from the ureteral orifices, minimizing the risk of upper tract injury during closure. Also, the rotation of the posterior urethra onto the anterior bladder wall secures the suture line high into the retropubic space, minimizing the risk of failure and postoperative fistula formation. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  18. Recombination chambers for BNCT dosimetry

    International Nuclear Information System (INIS)

    Tulik, Piotr

    2006-01-01

    Parallel plate recombination ionization chambers are known as the detectors which can be used for determination of gamma and high-LET dose components and for characterization of radiation quality of mixed radiation fields. Specially designed chambers can operate correctly even at dose rates of therapeutic beams. In this work the investigations were extended to a set of cylindrical chambers including a TE chamber and three graphite chambers filled with different gases - CO 2 , N 2 and 10 BF 3 , in order to determine the thermal neutrons, 14 N capture, gamma, and fast neutron dose components. The separation of the dose components is based on differences of the shape of the saturation curve, in dependence on LET spectrum of the investigated radiation. The measurements using all the chambers and a parallel plate recombination chamber were performed in a reactor beam of NRI Rez (Czech Republic). The gamma component was determined with accuracy of about 5%, while the variations of its value could be monitored with accuracy of about 0.5%. Relative changes of the beam components could be detected with accuracy of about 5% using the parallel plate chamber. The use of the chambers filled with different gases considerably improved the resolution of the method. (author)

  19. Variations of posterior vitreous detachment

    OpenAIRE

    Kakehashi, A.; Kado, M.; Akiba, J.; Hirokawa, H.

    1997-01-01

    AIMS—To identify variations in posterior vitreous detachment (PVD) and establish a clinical classification system for PVD.
METHODS—400 consecutive eyes were examined using biomicroscopy and vitreous photography and classified the PVD variations—complete PVD with collapse, complete PVD without collapse, partial PVD with thickened posterior vitreous cortex (TPVC), or partial PVD without TPVC.
RESULTS—In each PVD type, the most frequently seen ocular pathologies were as follows: in complete PVD ...

  20. The Incidence and Topographic Distribution of Sutures Including Wormian Bones in Human Skulls.

    Science.gov (United States)

    Cirpan, Sibel; Aksu, Funda; Mas, Nuket

    2015-07-01

    The Wormian Bones are accessory bones located within the cranial sutures and fontanelles. The present article examines the incidence of Wormian Bones and compares the number and topographic distribution between the sutures including Wormian Bones in skulls of West Anatolian Population. One hundred fifty crania were examined. The parameters evaluated in the present study were as follows: the rate of skulls including Wormian Bones; the topographic distribution and frequencies of the sutures including Wormian Bones; the number of these sutures for each skull; the name and number of sutures that were bilaterally and symmetrically located on the right and left side of skull (paired sutures) and which coincidentally had Wormian Bones for each skull; the differences of frequencies between the paired sutures including Wormian Bones. The rate of skulls including Wormian Bones was determined as 59.3%. The maximum and minimum numbers of sutures, including Wormian Bones, were 6 in 1 skull and 1 in each of 30 skulls, respectively. The maximum and minimum rates of sutures that had Wormian Bones were found in left lambdoid 40.7% and right occipitomastoid 1.3% sutures, respectively. There was only a significant difference between the rate of right and left squamous sutures (P = 0.04). Forty-five skulls were including 55 pairs of bilaterally and symmetrically located sutures that coincidentally had Wormian Bones in each pair. Each of 35 skulls had 1 pair of sutures including Wormian Bones and each of 10 skulls had 2 pairs. In the present study, the rate of Wormian Bones was determined as 59.3% in West Anatolian Population. This incidence rate is considerably lower than the other reports, and it may be as a result of racial variations. These divergent bones were more frequently found in left lambdoid sutures (40.7%) and less frequently in right occipitomastoid sutures (1.3%). This study may guide the investigators dealing with the neurosurgery, orthopedy, radiology, anatomy, and

  1. [Posterior ventricular septal perforation successfully repaired through right ventricular approach].

    Science.gov (United States)

    Takeuchi, Kazuma; Morishige, N; Iwahashi, H; Hayashida, Y; Teshima, H; Ito, N; Tashiro, T

    2006-12-01

    A 65-year-old man underwent a successful repair of a posterior ventricular septal perforation (VSP) 9 days after suffering an acute inferior myocardial infarction. After hospitalization, his hemodynamic condition gradually worsened, in spite of administering intensive medical therapy. Emergent operation was performed on the 4th day after onset. An equine pericardial patch was sutured around the VSP through the right ventricular side of the septum using the double-patch repair method and the right ventricular wall was closed as using the standard extracorporeal perfusion technique. The dimensions of the VSP measured 5 mm in diameter. Transesophageal echocardiography was performed on the 14th postoperative day. Cardiac catheter examination was done on the 18th postoperative day. No residual shunt was recognized and cardiac function was good. He was discharged on the 20th postoperative day. The occurrence of a posterior VSP is comparatively rare, and repair of VSP is difficult to perform during an acute period. Therefore, the operative results of VSP cases remain poor.

  2. Is the asterion a reliable landmark for the lateral approach to posterior fossa?

    Science.gov (United States)

    Uz, A; Ugur, H C; Tekdemir, I

    2001-03-01

    An anatomical study was conducted to gain orientation regarding the posterolateral approaches. The asterion is defined as the junction of the lambdoid, parietomastoid, and occipitomastoid sutures. This anatomical point has been widely used as a landmark in lateral approaches to posterior fossa. Although there are many common practices in posterolateral approaches, studies providing accurate anatomical knowledge as to what is the correct point to start a craniotomy are limited in number. Therefore, this study was conducted in an attempt to determine the reliability of the asterion for the posterolateral approaches as surgical landmark.

  3. Case of colonic intussusception secondary to mobile cecum syndrome repaired by laparoscopic cecopexy using a barbed wound suture device.

    Science.gov (United States)

    Yamamoto, Tetsu; Tajima, Yoshitsugu; Hyakudomi, Ryoji; Hirayama, Takanori; Taniura, Takahito; Ishitobi, Kazunari; Hirahara, Noriyuki

    2017-09-21

    A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was compatible with the diagnosis of cecal intussusception. The intussusception was spontaneously resolved at that time, but it relapsed 6 mo later. The patient underwent a successful colonoscopic disinvagination; there was no evidence of neoplastic or inflammatory lesions in the colon and terminal ileum. The patient underwent laparoscopic surgery for recurring cecal intussusception. During laparoscopy, we observed an unfixed cecum on the posterior peritoneum (i.e. a mobile cecum). Thus, we performed laparoscopic appendectomy and cecopexy with a lateral peritoneal flap using a barbed wound suture device. The patient's post-operative course was uneventful, and he continued to do well without recurrence at 10 mo after surgery. Laparoscopic cecopexy using a barbed wound suture device is a simple and reliable procedure that can be the treatment of choice for recurrent cecal intussusception associated with a mobile cecum.

  4. Effects of three suture techniques on complications after choledochojejunostomy

    Directory of Open Access Journals (Sweden)

    ZHOU Jinhang

    2015-10-01

    Full Text Available ObjectiveTo observe the effects of different suture techniques on complications after choledochojejunostomy. MethodsA retrospective analysis was performed on the clinical data of 162 patients who underwent choledochojejunostomy from January 2005 to December 2014 in our hospital. The patients were divided into group A undergoing simple interrupted suture (n=68, group B undergoing simple continuous suture (n=45, and group C undergoing parachute type continuous suture (n=49. The intraoperative conditions and postoperative complications were compared between the three groups. Comparison of continuous data between the three groups was made by ANOVA and pairwise comparison between any two groups was made by LSD t-tests; comparison of categorical data between the groups was made by chi-square test. ResultsThe anastomosis time and the rate of T-tube insertion showed significant differences between the three groups (P<0.05. Groups B and C had significantly shorter anastomosis time than group A(P<0.001, but there was no significant difference in the anastomosis time between groups B and C (P>0.05. Among the three groups, group A had the highest rate of T-tube insertion; group B had the second highest rate; group C had the lowest rate. Significant differences were found between any two groups in the rate of T-tube insertion by pairwise comparison (P<0.05. However, there were no significant differences between the three groups in the incidence rates of postoperative bile leakage and choleperitonitis (P>0.05. There was significant difference in biliary stricture between the three groups in the follow-up examination 6 months after surgery (P<0.001 and the differences analyzed by pairwise comparison were also significant (P<0.05. Among the three groups, the degree of biliary stricture in the group A was the highest and that in the group C was the lowest. ConclusionParachute-type continuous suture is a fine suture technique for

  5. An implantable sensor device measuring suture tension dynamics: results of developmental and experimental work.

    Science.gov (United States)

    Schachtrupp, A; Wetter, O; Höer, J

    2016-08-01

    Knowledge about suture tension dynamics after laparotomy closure is limited due to the lack of adequate measurement tools. As a consequence, a miniaturized implantable sensor and data logger were developed and applied experimentally in a porcine model to measure suture tension dynamics after laparotomy closure. We developed an implantable device (6 × 3 × 1 mm) fitted with silicon strain gauges and an implantable data logger allowing long-term registration. In nine domestic pigs, sensors and loggers were implanted along the suture closing a median laparotomy registering suture tension over a period of 23 h. Fascial closure was achieved by a mean suture tension of 1.07 N. After 30 minutes, suture tension was reduced to 0.81N (-24.3 %, p = 0.0003). After 12 h, tension showed a further decrease to 0.69 N (-35.5 %, n.s.), after 23 h mean suture tension reached 0.56 N, (-47.7 %, p = 0.014). The aim to develop an implantable miniaturized sensor device registering long-term suture tension dynamics was achieved. The use in the animal experiment was feasible and safe. We observed a loss of almost 50 % of suture tension 23 h after fascial closure. This could mean that up to 50 % of initial suture tension may be an unnecessary surplus not contributing to tissue stability but to the risk of suture failure.

  6. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  7. Rupture pressure of the posterior lamella obtained during big-bubble deep anterior lamellar keratoplasty.

    Science.gov (United States)

    McKee, Hamish D; Barua, Ankur; Brahma, Arun K; Jhanji, Vishal; Carley, Fiona M

    2012-11-01

    To investigate the pressure required to rupture the posterior lamella obtained during the presumed Descemet membrane-baring big-bubble technique of deep anterior lamellar keratoplasty (DALK). DALK using the big-bubble technique was carried out on donor corneoscleral discs mounted on an artificial anterior chamber. Once the anterior lamella was removed, the chamber was connected to a mercury manometer. The pressure inside the chamber was increased until rupture occurred or the manometer reached its measurement limit. The deep lamella ruptured at 252 mm Hg in one cornea, at 270 mm Hg in another, and had not ruptured at 300 mm Hg (upper limit of the manometer) in the remaining 18 donor corneas. The posterior lamella of big-bubble DALK probably confers significant structural integrity on the globe.

  8. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  9. Sandwich wound closure reduces the risk of cerebrospinal fluid leaks in posterior fossa surgery

    Directory of Open Access Journals (Sweden)

    Verena Heymanns

    2016-07-01

    Full Text Available Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8% in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark, Gelfoam® (Pfizer Inc., New York, NY, USA and polymethylmethacrylate (osteoclastic craniotomy. The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

  10. Randomized clinical trial comparing manual suture and different models of mechanical suture in the mimicking of bariatric surgery in swine

    Directory of Open Access Journals (Sweden)

    Fernandes MA

    2014-02-01

    Full Text Available Marcos AP Fernandes,1 Bruno MT Pereira,2 Sandra M Guimarães,1 Aline Paganelli,3 Carlos Manoel CT Pereira,1 Claudio Sergio Batista4 1Institute of Obesity and Advanced Video Laparoscopic Surgery of Petropolis, Rio de Janeiro, Brazil; 2Division of Trauma, University of Campinas, São Paulo, Brazil; 3Laboratório de Patologia Micron Cell Diagnóstico, Rio de Janeiro, Brazil; 4Department of Gynecology and Obstetrics, Faculty of Medicine of Petropolis, Rio de Janeiro, Brazil Context and objective: Variations in the ability of surgeons served as motivation for the development of devices that, overcoming individual differences, allow the techniques to be properly performed, and of which the end result was the best possible. Every technique must be reproduced reliably by the majority of surgeons for their results to be adopted and recognized as effective. The aim of this study was to compare the results, from the point of view of anatomic pathology, of manual sutures versus mechanical sutures using different models of linear mechanical staplers, in the procedure of gastroenteroanastomosis and enteroanastomosis in swine. Methods: Thirty-six healthy, adult, male Sus scrofa domesticus pigs, weighing between 20.7 and 25.5 kg, were used. The swine were randomly divided into four groups of nine pigs, according to the type of suture employed: group A, manual suture with Polysorb® 3-0 wire; group B, 80-shear linear stapler (Covidien® Gia 8038-S; group C, 75-shear linear stapler (Ethicon® Tlc 75; and group D, 75-shear linear stapler (Resource® Yq 75-3. A temporal study was established on the seventh postoperative day for histopathological analysis, and the degree of inflammation, fibrosis, and newly formed vessels, as well as the presence or absence of granulation tissue, foreign body granuloma, and necrosis were all evaluated qualitatively and semiquantitatively. The results were analyzed statistically. Results: Observations during the histopathological

  11. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate patternvscircular pattern with vitreous strand cutting.

    Science.gov (United States)

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting. A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. In both groups, the BCVA improved significantly ( P pattern group, P =0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased ( P pattern group and P =0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  12. Syneture stainless STEEL suture. A collective review of its performance in surgical wound closure.

    Science.gov (United States)

    Edlich, Richard F; Drake, David B; Rodeheaver, George T; Winters, Kathryne L; Greene, Jill A; Gubler, K Dean; Long, William B; Britt, L D; Winters, Samuel P; Scott, Christine C; Lin, Kant Y

    2006-01-01

    Syneture (division of U.S. Surgical, division of Tyco Healthcare, Norwalk, Connecticut, USA) STEEL sutures are monofilament stainless steel sutures composed of 316L stainless steel conforming to ASTM Standard F138 grade 2 (" Stainless steel bar and wire for surgical implant"). STEEL sutures meet all requirements established by the United States Pharmacopeia (USP) for nonabsorbable surgical sutures. Steel sutures are for use in abdominal wound closure, intestinal anastomosis, hernia repair, sternal closure, and skin closure. They are attached to the following types of surgical needles: Roto-Grip Needles and SCC Needle. The sutures and needles are packaged in a Mylar/Tyvek outer envelope. The purposes of this clinical review are two fold. First, we will report the performance of the Syneture STEEL suture product in the largest studies of suture performance ever reported in the literature. In addition, we will provide comprehensive information from the surgical literature that highlights the unique benefits of stainless steel sutures for the following wound closure techniques: sternal fixation, abdominal wound repair, inguinal hernia repair, and skin wound closure. Consorta Inc. (Rolling Meadows, Illinois), a leading healthcare resource management group purchasing organization, and Syneture, jointly with a clinician task force, designed a reproducible surgical evaluation program for needles and sutures in a large cooperative of healthcare systems. Because of the subjective nature of the more commonly used suture selection techniques, a nonexperimental observational study approach was designed to replace perception of performance characteristics with actual clinical experience. In a report involving 19 Consorta shareholder hospitals, they discussed the preliminary part (Phase I) of a large nonexperimental observational study of the clinical performance of surgical needles and sutures. Performance characteristics of the sutures and needles produced by Syneture that were

  13. Endoscopic management of posterior epistaxis.

    Science.gov (United States)

    Paul, J; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-04-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26-50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of the bleeding vessel. Of these, in four cases unsuspected diagnosis was made. Of the remaining 19, in three patients, the bleeding point could not be localized accurately and these patients were managed by anteroposterior packing. The rest of the 16 patients were managed by endoscopic cauterization. In four patients, there was recurrence of bleeding within 24 h. In one of these, cauterization controlled the bleeding while in the rest nasal packing had to be resorted to. Thus, of the 23 patients of posterior epistaxis subjected to nasal endoscopy, we could avoid nasal packing in 17 (74%). To conclude, endoscopic nasal cauterization is recommended as the first line to treatment in all cases of posterior epistaxis. This will not only prevent the uncomfortable and potentially dangerous nasal packing but also help in finding the underlying pathology.

  14. The high momentum spectrometer drift chambers

    Science.gov (United States)

    Abbott, D.; Baker, O. K.; Beaufait, J.; Bennett, C.; Bryant, E.; Carlini, R.; Kross, B.; McCauley, A.; Naing, W.; Shin, T.; Vulcan, W.

    1992-12-01

    The High Momentum Spectrometer in Hall C will use planar drift chambers for charged particle track reconstruction. The chambers are constructed using well understood technology and a conventional gas mixture. Two (plus one spare) drift chambers will be constructed for this spectrometers. Each chamber will contain 6 planes of readout channels. This paper describes the chamber design and gas handling system used.

  15. Self-directed practice schedule enhances learning of suturing skills.

    Science.gov (United States)

    Safir, Oleg; Williams, Camille K; Dubrowski, Adam; Backstein, David; Carnahan, Heather

    2013-12-01

    Most preoperative surgical training programs experience challenges with the availability of expert surgeons to teach trainees. Some research suggests that trainees may benefit from being allowed to actively shape their learning environments, which could alleviate some of the time and resource pressures in surgical training. The purpose of this study was to investigate the effects of self-directed or prescribed practice schedules (random or blocked) on learning suturing skills. Participants watched an instructional video for simple interrupted, vertical mattress and horizontal mattress suturing then completed a pretest to assess baseline skills. Participants were assigned to 1 of 4 practice groups: self-directed practice schedule, prescribed blocked practice schedule, prescribed random practice schedule or matched to the self-directed group (control). Practice of the skill was followed by a delayed (1 h) posttest. Improvement from pretest to posttest was determined based on differences in performance time and expert-based assessments. Analyses revealed a significant effect of group for difference in performance time of the simple interrupted suture. Random practice did not show the expected advantage for skill learning, but there was an advantage of self-directed practice. Self-directed practice schedules may be desirable for optimal learning of simple technical skills, even when expert instruction is available. Instructors must also take into account the interaction between task difficulty and conditions of practice to develop ideal training environments.

  16. Intraoperative adjustable suture surgery for bilateral superior oblique palsy.

    Science.gov (United States)

    Ohtsuki, H; Hasebe, S; Hanabusa, K; Fujimoto, Y; Furuse, T

    1994-01-01

    The modified Harada-Ito procedure has been reported to be an effective treatment for correction of cyclotorsion in bilateral superior oblique palsy. However, there are no reports regarding its use in intraoperative adjustable suture surgery. The authors performed a retrospective study of 12 patients with traumatic bilateral superior oblique palsy who were classified as having either symmetric or asymmetric palsy according to the symmetry of the alternate hyperdeviation on side gazes. Cyclotorsion and vertical and horizontal deviation in the nine diagnostic positions were measured preoperatively and postoperatively. Of the 12 patients, 6 were determined to have symmetric palsy and 6 asymmetric palsy. Intraoperative adjustable suture surgery with the modified Harada-Ito procedure was performed bilaterally in the six patients with symmetric palsy and unilaterally in those with asymmetric palsy. The median measured value of extorsion in the primary position was reduced from 14.5 degrees to 2.5 degrees in patients with symmetric palsy and from 9.5 degrees to 2.0 degrees in those with asymmetric palsy. In downgaze, some degree of residual extorsion remained, and there was no significant change in esodeviation after surgery. In five patients with symmetric palsy and in all of those with asymmetric palsy, normal single binocular vision in the primary position but did not that in downgaze was restored after surgery. Intraoperative adjustable suture surgery is an effective treatment in correcting torsion, but may not be as effective for esodeviation in downgaze.

  17. Rethinking "posterior" tongue-tie.

    Science.gov (United States)

    Douglas, Pamela Sylvia

    2013-12-01

    Currently, many clinicians who help with breastfeeding problems are diagnosing "posterior" tongue-tie in infants and performing or referring for frenotomy. In this "Speaking Out" article, I argue that the diagnosis of "posterior" tongue-tie has successfully raised awareness of the importance of impaired tongue function in breastfeeding difficulty. However, the diagnosis of "posterior" tongue-tie also applies a reductionist, medicalized theoretical frame to the complex problem of impaired tongue function, risking unintended outcomes. Impaired tongue function arises out of multiple interacting and co-evolving factors, including the interplay between social behaviors concerning breastfeeding and mother-infant biology. Consideration of theoretical frames is vital if we are to build an evidence base through efficient use of the scarce resources available for clinical breastfeeding research and minimize unintended outcomes.

  18. Epidural hematomas of posterior fossa

    Directory of Open Access Journals (Sweden)

    Radulović Danilo

    2004-01-01

    Full Text Available Background. Posterior fossa epidural hematomas represent 7-14% of all traumatic intracranial epidural hematomas. They are most frequently encountered posttraumatic mass lesions in the posterior fossa. The aim of this study was to identify clinical features that could lead to the early diagnosis of posterior fossa epidural hematoma. Methods. Between 1980 and 2002, 28 patients with epidural hematoma of the posterior fossa were operated on at the Institute for Neurosurgery, Belgrade. Clinical course neuroradiological investigations, and the results of surgical treatment of the patients with posterior fossa epidural hematomas were analyzed retrospectively. Results. Almost two thirds of patients were younger than 16 years of age. In 20 cases injury was caused by a fall, in 6 cases by a traffic accident, and in 2 by the assault. Clinical course was subacute or chronic in two thirds of the patients. On the admission Glasgow Coma Scale was 7 or less in 9 injured, 8-14 in 14 injured, and 15 in 5 injured patients. Linear fracture of the occipital bone was radiographically evident in 19 patients, but was intraoperatively encountered in all the patients except for a 4-year old child. In 25 patients the diagnosis was established by computer assisted tomography (CAT and in 3 by vertebral angiography. All the patients were operated on via suboccipital craniotomy. Four injured patients who were preoperatively comatose were with lethal outcome. Postoperatively, 24 patients were with sufficient neurologic recovery. Conclusion. Posterior fossa epidural hematoma should be suspected in cases of occipital injury, consciousness disturbances, and occipital bone fracture. In such cases urgent CAT-scan is recommended. Early recognition early diagnosis, and prompt treatment are crucial for good neurological recovery after surgery.

  19. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  20. Neutron detection via bubble chambers.

    Science.gov (United States)

    Jordan, D V; Ely, J H; Peurrung, A J; Bond, L J; Collar, J I; Flake, M; Knopf, M A; Pitts, W K; Shaver, M; Sonnenschein, A; Smart, J E; Todd, L C

    2005-01-01

    Research investigating the application of pressure-cycled bubble chambers to fast neutron detection is described. Experiments with a Halon-filled chamber showed clear sensitivity to an AmBe neutron source and insensitivity to a (137)Cs gamma source. Bubble formation was documented using high-speed photography, and a ceramic piezo-electric transducer element registered the acoustic signature of bubble formation. In a second set of experiments, the bubble nucleation response of a Freon-134a chamber to an AmBe neutron source was documented with high-speed photography.

  1. Neutron detection via bubble chambers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, D.V. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States)]. E-mail: david.jordan@pnl.gov; Ely, J.H. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Peurrung, A.J. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Bond, L.J. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Collar, J.I. [Department of Physics and Enrico Fermi Institute, University of Chicago, 5640 S. Ellis Ave., LASR 214, Chicago, IL 60637 (United States); Flake, M. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Knopf, M.A. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Pitts, W.K. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Shaver, M. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Sonnenschein, A. [Department of Physics and Enrico Fermi Institute, University of Chicago, 5640 S. Ellis Ave., LASR 214, Chicago, IL 60637 (United States); Smart, J.E. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Todd, L.C. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States)

    2005-12-01

    Research investigating the application of pressure-cycled bubble chambers to fast neutron detection is described. Experiments with a Halon-filled chamber showed clear sensitivity to an AmBe neutron source and insensitivity to a {sup 137}Cs gamma source. Bubble formation was documented using high-speed photography, and a ceramic piezo-electric transducer element registered the acoustic signature of bubble formation. In a second set of experiments, the bubble nucleation response of a Freon-134a chamber to an AmBe neutron source was documented with high-speed photography.

  2. Pelletron general purpose scattering chamber

    International Nuclear Information System (INIS)

    Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh

    1993-01-01

    A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs

  3. The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair.

    Science.gov (United States)

    Wieskötter, B; Herbort, M; Langer, M; Raschke, M J; Wähnert, D

    2018-01-01

    Flexor tendon repair consists of circumferential peripheral sutures in combination with core sutures to avoid fraying and reduces the exposure of suture material on tendon surface. The peripheral suture adds up to a tenfold increase of the biomechanical stability compared to the core suture alone. The purpose of our study was to determine the most favourable peripheral repair technique for tendon repair. Seventy-two porcine flexor tendons underwent standardized tenotomy and repair using one of the following six methods (n = 12): simple-running (SR), simple-locking (SL), Halsted-mattress (HM), lin-locking (LL), Lembert-mattress (LM), and Silfverskiöld cross-stich (SCS) suture technique. The SL- suture was placed 2 mm; the HM, LM, SC, and LL suture were placed 5 mm from the tendon gap. The SR suture was placed 1, 2, and 3 mm from tendon ends; no additional core suture was applied. For cyclic testing (1000 cycles), elongation was calculated; for load to failure construct stiffness, yield load and maximum load were determined. The mean cyclic elongation for all tested suture techniques was less than 2 mm; there was no significant difference between the groups regarding elongation as well as yield load. The HM, LM, SCS, and LL suture techniques presented significantly higher maximum loads compared to the SR- and SL-sutures. The 3 mm SR showed significantly higher maximum loads compared to the 2 and 1 mm SR. Beside the distance from tendon gap, the type of linkage of the suture material across and beneath the epitendineum is important for biomechanical stability. Simple-running suture is easy to use, even with a slight increase of the distance from tendon gap significantly increases biomechanical strength. For future repairs of flexor tendon injuries, 3 mm stitch length is highly recommended for simple peripheral suture, while the Halsted-mattress suture unites the most important qualities: biomechanically strong, most part of suture material placed

  4. Posterior and anterior fixation of the urethra during robotic prostatectomy improves early continence rates.

    Science.gov (United States)

    Koliakos, Nikolaos; Mottrie, Alexandre; Buffi, Nicolo; De Naeyer, Geert; Willemsen, Pieter; Fonteyne, Etienne

    2010-02-01

    To investigate whether posterior and anterior fixation of the vesicourethral anastomosis during robotic radical prostatectomy (RRP) helps to establish continence earlier. Forty-seven consecutive patients undergoing RRP were randomized into two groups. The first group received a typical Van Velthoven vesicourethral anastomosis and the second group a modified anastomosis with posterior and anterior fixation. In this group the posterior fibrous tissues of the sphincter were sutured to the residual Denonvilliers' fascia. The anastomosis with two running sutures started at the 6 o'clock position on the bladder neck and continued upwards. Two-step stitching was done on the upper half of the anastomosis to ensure good stabilization of the bladder: a small portion of urethral stump followed by a deep haemostatic stitch on the plexus. Continence, as measured by patient self-reporting of the number of pads used per 24 h, was assessed 7 weeks after catheter removal, by telephone interview. The use of no pads or one pad was defined as "continent", two pads as "moderate incontinence" and more than two pads as "severe incontinence". At catheter removal, more patients in the fixation group were continent than in the Van Velthoven group [9/23 (39%) vs 3/24 (12.5%), p = 0.036]. At 7 weeks, continence was even better in the fixation group [15/23 (65%) vs 8/24 (33%), p = 0. 029]. The mean pad usage was less in the fixation group (1.43 vs 2.25, p = 0.032). The posterior and anterior fixation of the vesicourethral anastomosis during RRP results in an intact sphincteric mechanism, because no stretch is applied to the urethra, resulting in earlier continence.

  5. Evaluation of a novel suture material for closure of intestinal anastomoses in canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2012-11-01

    To compare leakage and maximum intraluminal pressures for a novel suture material with pressures for comparable suture material when used in closure of intestinal anastomoses in canine cadavers. Healthy intestines from cadavers of dogs euthanized for reasons unrelated to the study. 18 anastomoses were performed on intestinal sections within 72 hours after dogs were euthanized and intestinal samples collected. Anastomoses were performed with a simple continuous suture pattern. Leakage and maximum intraluminal pressures were measured and recorded for 6 control segments and 18 anastomosed sections. A barbed glycomer 631 suture (size 4-0 United States Pharmacopeia [USP]) was compared with glycomer 631 sutures (sizes 3-0 and 4-0 USP). Results for leakage and maximum intraluminal pressures were compared via an ANOVA. The barbed glycomer 631 suture material leaked at a significantly higher pressure than did the comparable glycomer 631 suture materials. Maximum intraluminal pressures were not significantly different among the suture materials. Barbed glycomer 631 4-0 USP suture material was as effective as glycomer 631 suture materials and may be a safe alternative for use in closure of enterectomies in dogs.

  6. Use of a barbed suture for laparoscopic closure of the internal inguinal rings in a horse.

    Science.gov (United States)

    Ragle, Claude A; Yiannikouris, Stavros; Tibary, Ahmed A; Fransson, Boel A

    2013-01-15

    A 4-year-old castrated Arabian horse was evaluated for a history of a right-sided nonstrangulating inguinal hernia that was manually reducable. Physical examination revealed a right-sided hydrocele and bilateral enlargement of the inguinal rings detectable by both external digital and rectal palpation. Biportal laparoscopic internal inguinal ring closure was performed with a continuous suture line of unidirectional barbed suture applied with a mechanical suturing instrument. The barbed suture contributed to a secure closure with the added benefit of not requiring knots to be tied at either the beginning or end of the suture line. Follow-up physical examination and laparoscopy confirmed healing of the surgical sites and a reduction in size of the inguinal rings. The horse exercised for 20 months following surgery without recurrence of the inguinal hernia. In horses, laparoscopic application of unidirectional barbed sutures should be considered among the treatment options for recurrent inguinal herniation. This technique was accomplished with only 2 portals/side, in contrast to the additional 3 to 4 portals that are most commonly required. The use of a barbed suture with a mechanical suturing instrument offered added security to the closure. The difficulties of dual instrument suturing and intracorporeal knot tying were eliminated, dramatically reducing the challenges of performing suture reduction of the internal inguinal ring.

  7. Skull morphometry and vault sutures of Myrmecophaga tridactyla and Tamandua tetradactyla

    Directory of Open Access Journals (Sweden)

    Camila M. de S. Hossotani

    2017-10-01

    Full Text Available ABSTRACT This study aimed to examine the relationship between skull size and the level of cranial vault suture closure. A total of 50 Myrmecophaga tridactyla Linnaeus, 1758 and 178 Tamandua tetradactyla Linnaeus, 1758 skulls were analyzed in relation to 18 skull dimensions. The skulls were grouped into three levels of suture closure: no sutures closed (level 0, one or all the fallowing sutures closed: interfrontalis, sagitalis and coronalis (level 1 and all sutures closed (level 2. The results indicated that among the 18 variables measured, 17 showed significant differences (p ≤ 0.01 between level 0 and level 1 skulls of T. tetradactyla; as well as between level 0 and level 1, and level 0 and level 2 skulls of M. tridactyla. M. tridactyla level 1 and level 2 had no significant difference among any of the 18 dimensions. The foramen magnum height in both species showed no significant difference (p > 0.05 among any suture categories. In principle, suture closure level and cranial dimensions are related. The specimens with larger cranial dimensions showed greater number of cranial vault sutures closed for both species of anteaters. Tamandua tetradactyla and M. tridactyla specimens with none of the cranial vault suture closed have a foramen magnum height similar to those with cranial vault suture closed.

  8. A National Survey of Undergraduate Suture and Local Anesthetic Training in the United Kingdom.

    Science.gov (United States)

    Rufai, Sohaib R; Holland, Luke C; Dimovska, Eleonora O F; Bing Chuo, Cher; Tilley, Simon; Ellis, Harold

    2016-01-01

    Suturing is a skill expected to be attained by all medical students on graduation, according to the General Medical Council's (GMC) Tomorrow's Doctors. There are no GMC recommendations for the amount of suture training required at medical school nor the level of competence to be achieved. This study examines the state of undergraduate suture training by surveying a sample of medical students across the United Kingdom. We distributed a survey to 17 medical schools to be completed by undergraduates who have undergone curricular suture training. The survey included questions relating to career intention, hours of curricular suture training, hours of additional paid training, confidence in performing various suture techniques and knowledge of their indications. We also asked about the students' perceived proficiency at injecting local anesthetic and their overall opinion of medical school suture training. We received responses from 705 medical students at 16 UK medical schools. A total of 607 (86.1%) medical students had completed their scheduled curricular suture training. Among them, 526 (86.5%) students reported inadequate suture training in medical school and 133 (21.9%) students had paid for additional training. Results for all competence markers were significantly lower than the required GMC standards (p Students who had paid for additional training were significantly more confident across all areas examined (p students surveyed. These findings suggest that medical schools should provide more opportunities for students to develop their suturing skills to achieve the GMC standard. Copyright © 2015. Published by Elsevier Inc.

  9. Suture compression induced midpalatal suture chondrocyte apoptosis with increased caspase-3, caspase-9, Bad, Bak, Bax and Bid expression.

    Science.gov (United States)

    Lan, Tingting; Zhao, Hanchi; Xiang, Bilu; Wang, Jun; Liu, Yang

    2017-07-22

    Previous studies found bone resorption and chondrocytes loss in mouse models of mid-palatal suture when given continuous compressive force, although chondrocytes response remained unknown. Herein, we design this study to determine how continuous compression force induces chondrocytes apoptosis. Thirty C57BL/6 male mice (aged 6 weeks) were randomly assigned into controls (not ligated to a spring), blank controls (ligated with no compression) and the compression group (ligated with 20-g compression). After 4 d, palatal tissues were sampled and stained by TB and safranin-O. Tunel staining measured the percentage of apoptotic chondrocytes, and immunohistochemistry was performed to label apoptosis-associated proteins (e.g., Bcl-2, Bcl-xl, Bax, Bak, Bid, Bad, caspase-3, caspase-8 and caspase-9). Intergroup comparison was made by the rank sum test, and P compression group was significantly decreased, while the control group remained largely unaltered. Tunel staining showed that apoptotic cell numbers in the mid-palatal suture were significantly higher than the control group. Immunohistochemistry showed that mice in the compression group had significantly increased expression of caspase-3, caspase-9, Bad, Bak, Bax and Bid; However, caspase-8 remained unaltered. No expression of Bcl-2 and Bcl-xl was detected. Continuous compression force induces chondrocytes apoptosis in the mid-palatal suture. This process might be associated with the mitochondrial pathway. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  11. Light diffusing fiber optic chamber

    Science.gov (United States)

    Maitland, Duncan J.

    2002-01-01

    A light diffusion system for transmitting light to a target area. The light is transmitted in a direction from a proximal end to a distal end by an optical fiber. A diffusing chamber is operatively connected to the optical fiber for transmitting the light from the proximal end to the distal end and transmitting said light to said target area. A plug is operatively connected to the diffusing chamber for increasing the light that is transmitted to the target area.

  12. Advances on fission chamber modelling

    International Nuclear Information System (INIS)

    Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob

    2013-06-01

    In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the

  13. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  14. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  15. Multiple Coronary Chamber Microfistulas or Persistent Thebesian Vessels?

    Directory of Open Access Journals (Sweden)

    Cernica Daniel

    2017-09-01

    Full Text Available Coronary fistulas are rare, not gender-specific congenital conditions, consisting of communications between the coronary arteries and either another coronary vessel or a cardiac chamber. In contrast to large fistulas, small fistulas, named “minimae cordis veneae” or the Thebesius venous system, are draining into heart chambers and form a vascular network in the cardiac lumen. In this article, we present the case of a 72-year-old female with a significant history of cardiovascular disease, admitted to our clinic because of rest dyspnea, fatigue, and minimal chest pain. The 12-lead electrocardiogram showed a trifascicular block (a second-degree atrioventricular block Mobitz II, associated with a right bundle branch block and left anterior fascicle block and negative T waves in DII, DIII, aVF, V4–V6 leads. An invasive coronary angiography was performed, which revealed no significant atherosclerotic lesions. However, a persistent capillary blush was present at the apex site of the left ventricular chamber, draining from the distal segments of both the anterior descending coronary artery and the posterior interventricular coronary artery. The intramural vascular network generating a left ventricle angiogram image of this kind was suggestive for persistent Thebesian vessels connecting the two coronaries with the left ventricular chamber.

  16. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    Directory of Open Access Journals (Sweden)

    Jeroni Nadal

    2015-01-01

    Full Text Available Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p=0.015 at 1 month, which persisted to 12 months (0.18 ± 0.60. Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%, vitreous hemorrhage in 2 eyes (8%, transient hypotony in 2 eyes (8%, and cystic macular edema in 1 eye (4%. No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  17. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach.

    Science.gov (United States)

    Nadal, Jeroni; Kudsieh, Bachar; Casaroli-Marano, Ricardo P

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA) LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p = 0.015) at 1 month, which persisted to 12 months (0.18 ± 0.60). Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%), vitreous hemorrhage in 2 eyes (8%), transient hypotony in 2 eyes (8%), and cystic macular edema in 1 eye (4%). No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  18. Posterior fossa meningioma (surgical experiences)

    African Journals Online (AJOL)

    Wael M. Moussa

    2012-08-27

    Aug 27, 2012 ... Abstract Introduction: Meningioma is a common tumor that represents about 30% of all intra- cranial tumors. Posterior fossa ... All patients had preoperative complete general and neurological examination, MRI of the brain with and without ..... in post-radiation nasopharyngeal carcinoma. Eur Radiol. 2009 ...

  19. A simple suture-retrieval device for the placement of u-stitches during laparoscopic gastrostomy.

    Science.gov (United States)

    Mattei, Peter

    2009-02-01

    During minimally invasive operations, it is sometimes necessary to retrieve the end of a suture or a suture needle and bring it out through the abdominal wall. Using a standard needle and a length of suture, we have developed a simple device that allows the retrieval of a suture end during minimally invasive operations that require the placement of U-or stay stitches. The author has used the device described during more than 100 laparoscopic gastrostomy placement procedures and other operations involving the placement of U- or stay stitches with excellent results and no complications. Using a beveled hollow-bore needle and a loop of polypropylene suture, one can construct a simple device that allows the retrieval of a suture from within a body cavity during minimally invasive surgery, making the placement of U- and stay stitches easier and more precise.

  20. Intraspecific variation of the interparietal suture closure in Siberian roe deer Capreolus pygargus from Jeju Island.

    Science.gov (United States)

    Oh, Jinwoo; Oh, Hong-Shik; Kimura, Junpei; Koyabu, Daisuke

    2017-12-22

    The sequence of cranial suture closure among cervids is reported to be generally species-specific and highly conservative within species. On the other hand, it is known that intraspecific variation often exists to some extent in other mammalian taxa. Here we studied the cranial suture closures of Capreolus pygargus from Jeju Island and compared it with other cervid species. We found that the timing of the interparietal suture closure is highly variable within C. pygargus. Capreolus capreolus similarly shows intraspecific variation of the interparietal suture closure, whereas other cervid species studied to date do not show any intraspecific variation in the sequence of cranial suture closure. Such high intraspecific variation of the interparietal suture may be a derived character for Capreolus.

  1. Quantitative physical and handling characteristics of novel antibacterial braided silk suture materials.

    Science.gov (United States)

    Chen, Xiaojie; Hou, Dandan; Tang, Xiaoqi; Wang, Lu

    2015-10-01

    Surgical braided silk sutures have been widely used because these materials exhibit good handling characteristics, ease of use, and ideal knot security. However, surgical silk sutures likely cause surgical site infections because these sutures are composed of natural protein materials with a braided structure. As such, antibacterial silk sutures for clinical wound closure should be developed. Braided silk suture could be treated and modified with antibacterial agent, provided that excellent physical and handling characteristics of this material should maximize maintained. This study aimed to quantitatively investigate the effect of antibacterial treatment with different parameters on physical and handling characteristics of novel antibacterial braided silk sutures. Physical and handling characteristics, including appearance, knot-pull tensile strength, pullout friction resistance, tissue drag friction resistance, and bending stiffness, were evaluated. After physical and handling tests were conducted, images showed morphological characteristics were obtained and evaluated to investigate the relationship between antibacterial treatment and physical and handling properties. Results showed that suture diameter increased and reached the nearest thick size specification; knot-pull tensile strength decreased but remained higher than the standard value by at least 40.73%. Fracture asynchronism during knot-pull tensile strength test suggested that the fineness ratio of shell and core strands may enhance knot-pull tensile strength. Static and dynamic frictions of suture-to-suture friction behavior were slightly affected by antibacterial treatment, and changed to less than 16.07% and 32.77%, respectively. Suture-to-tissue friction and bending stiffness increased by approximately 50%; the bending stiffness of the proposed suture remained efficient compared with that of synthetic sutures. Therefore, good physical and handling characteristics can be maintained by selecting

  2. Enterotomy closure using knotless and barbed suture in laparoscopic upper gastrointestinal surgeries.

    Science.gov (United States)

    Bautista, Therese; Shabbir, Asim; Rao, Jaideepraj; So, Jimmy; Kono, Koji; Durai, Pradeep

    2016-04-01

    Barbed sutures are recently being employed in intracorporeal suturing in various laparoscopic digestive surgeries. The purpose of this paper was to present our initial experience of enterotomy closure with barbed sutures in upper gastrointestinal and bariatric surgeries, and share optimal technique of using such sutures for enterotomy closure. Fifty patients who underwent laparoscopic closure of enterotomies using barbed sutures were identified in two institutions in Singapore from January 2012 to December 2013. Patient demographics, short-term operative outcomes including anastomotic time, onset of diet, hospital stay, and early post-operative complications are reported. In 50 patients a total of 62 anastomotic sites were closed with barbed sutures. The barbed sutures appear to reduce mean anastomotic suturing time of the Roux-en-Y gastrojejunal closure (17.34 vs 44.55 min, p value 0.0001) and jejunojejunal closure (19.46 vs 31.01 min, p value 0.0013) when compared to a subgroup of patients with the same anastomotic sites closed using the standard non-barbed suture. The mean onset to start on diet was 2 ± 1.5 days and mean duration of hospital stay is 7 + 5.3 days. One (1.6%) anastomotic leak was observed day 3 after a gastric bypass in the series. This leak was the result of a technical error due to inappropriate suturing technique. There were no mortalities, other complications or readmission. While applying traction on the suture brings two tissue edges closer, we observed that pushing the tissues toward each other provided more apposition and prevented unnecessary tearing of tissues that could potentially result in complications Barbed closure sutures appear to be safe and effective in laparoscopic upper gastrointestinal procedures for closing enterotomies provided appropriate technique is used. The potential benefit is simplifying intracorporeal enterotomy closure.

  3. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    Science.gov (United States)

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  4. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  5. Comparison of 10-0 polypropylene and 10-0 nylon sutures in rat arterial anastomosis.

    Science.gov (United States)

    Chen, L E; Seaber, A V; Urbaniak, J R

    1993-01-01

    The selection of suture materials is an important factor in further improving the results of microsurgical operations. In this study, two kinds of nonabsorbable suture materials, 10-0 polypropylene and 10-0 nylon monofilament, were compared in end-to-end anastomosis of 66 femoral arteries of adult rats. Both suture types were of identical size (70 microns needle/28 microns suture) and each artery received eight sutures. The vessels were harvested at various intervals from 2 hr to 180 days postoperatively and were evaluated by pathology, radiology, and tensile strength test. The results show that both sutures are capable of achieving excellent long-term patency (100%) of anastomosed sites. Polypropylene suture was equivalent to nylon in mechanical integrity of the anastomosis sites but was superior in handling, knotting, and biocompatibility. These physical and biological properties of polypropylene sutures may offer the benefits of diminished early and late complications at anastomosis sites and reduced operation time. Enhancement of contrast against surrounding tissue may make polypropylene a superior alternative to nylon sutures for microsurgical use.

  6. Risk factors for suture requirement and early hypotony in 23-gauge vitrectomy for complex vitreoretinal diseases.

    Science.gov (United States)

    Küçük, Erkut; Yılmaz, Uğur; Zor, Kürşad Ramazan; Kalaycı, Defne; Sarıkatipoğlu, Hikmet

    2017-08-01

    To find out the rate of suture requirement and post-operative hypotony in a series of 23-gauge pars plana vitrectomy cases and analyze the factors affecting post-operative hypotony and leakage of sclerotomy leading to suture placement. This is a single-center retrospective interventional case series. Eighty-four eyes underwent 23-gauge vitrectomy. Primary endpoint measures were rate of leakage of 23-gauge sclerotomies requiring suture placement at the end of surgery and rate of early post-operative hypotony. Secondary endpoint measures were risk factors for early hypotony and leakage requiring suture placement at the end of surgery. Suture placement in at least one sclerotomy because of sclerotomy leakage was required in 28.6 % (24 of 84) of eyes at the end of surgery. Early post-operative hypotony was seen in 14.3 % (12 of 84). Silicone oil endotamponade and single-step surgery were found as factors increasing the risk of sclerotomy leakage leading to suture placement. Suture placement was the only significant factor increasing the risk of early post-operative hypotony. Sclerotomy sutures may be required in 23-gauge surgery, more frequently in cases of single-step sclerotomy and/or silicone oil endotamponade. Meticulous suturation of leaking sclerotomies may decrease the rate of post-operative hypotony.

  7. Osteoprotegerin deficiency results in disruption of posterofrontal suture closure in mice: implications in nonsyndromic craniosynostosis.

    Science.gov (United States)

    Beederman, Maureen; Kim, Stephanie H; Rogers, M Rose; Lyon, Sarah M; He, Tong-Chuan; Reid, Russell R

    2015-06-01

    Little is known about the role of osteoclasts in cranial suture fusion. Osteoclasts are predominantly regulated by receptor activator of nuclear factor kappa B and receptor activator of nuclear factor kappa B ligand, both of which lead to osteoclast differentiation, activation, and survival; and osteoprotegerin, a soluble inhibitor of receptor activator of nuclear factor kappa B. The authors' work examines the role of osteoprotegerin in this process using knockout technology. Wild-type, osteoprotegerin-heterozygous, and osteoprotegerin-knockout mice were imaged by serial micro-computed tomography at 3, 5, 7, 9, and 16 weeks. Suture density measurements and craniometric analysis were performed at these same time points. Posterofrontal sutures were harvested from mice after the week-16 time point and analyzed by means of histochemistry. Micro-computed tomographic analysis of the posterofrontal suture revealed reduced suture fusion in osteoprotegerin-knockout mice compared with wild-type and heterozygous littermates. Osteoprotegerin deficiency resulted in a statistically significant decrease in suture bone density in knockout mice. There was no reduction in the density of non-suture-containing calvarial bone between wild-type and osteoprotegerin-knockout mice. Histochemistry of suture sections supported these micro-computed tomographic findings. Finally, osteoprotegerin-knockout mice had reduced anteroposterior skull distance at all time points and an increased interorbital distance at the week-16 time point. The authors' data suggest that perturbations in the expression of osteoprotegerin and subsequent changes in osteoclastogenesis lead to alterations in murine cranial and posterofrontal suture morphology.

  8. Surgical sutures filled with adipose-derived stem cells promote wound healing.

    Directory of Open Access Journals (Sweden)

    Ann Katharin Reckhenrich

    Full Text Available Delayed wound healing and scar formation are among the most frequent complications after surgical interventions. Although biodegradable surgical sutures present an excellent drug delivery opportunity, their primary function is tissue fixation. Mesenchymal stem cells (MSC act as trophic mediators and are successful in activating biomaterials. Here biodegradable sutures were filled with adipose-derived mesenchymal stem cells (ASC to provide a pro-regenerative environment at the injured site. Results showed that after filling, ASCs attach to the suture material, distribute equally throughout the filaments, and remain viable in the suture. Among a broad panel of cytokines, cell-filled sutures constantly release vascular endothelial growth factor to supernatants. Such conditioned media was evaluated in an in vitro wound healing assay and showed a significant decrease in the open wound area compared to controls. After suturing in an ex vivo wound model, cells remained in the suture and maintained their metabolic activity. Furthermore, cell-filled sutures can be cryopreserved without losing their viability. This study presents an innovative approach to equip surgical sutures with pro-regenerative features and allows the treatment and fixation of wounds in one step, therefore representing a promising tool to promote wound healing after injury.

  9. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Sutker, Michael J

    2009-09-01

    To evaluate the biomechanical characteristics of current meniscal repair techniques containing ultra high-molecular weight polyethylene (UHMWPE) suture with and without cyclic loading. Vertical longitudinal cuts made in porcine menisci were secured with a single repair device. Noncycled and cycled (500 cycles) biomechanical tests were performed on the following groups: group 1, No. 2-0 Mersilene vertical suture (Ethicon, Somerville, NJ); group 2, No. 2-0 Orthocord vertical suture (DePuy Mitek, Westwood, MA); group 3, No. 0 Ultrabraid vertical suture (Smith & Nephew Endoscopy, Andover, MA); group 4, No. 2-0 FiberWire vertical suture (Arthrex, Naples, FL); group 5, vertically oriented mattress suture by use of an Ultra FasT-Fix device (Smith & Nephew Endoscopy) with No. 0 Ultrabraid; group 6, vertically oriented mattress suture by use of a RapidLoc A2 device (DePuy Mitek) with No. 2-0 Orthocord suture; group 7, vertically oriented stitch by use of a MaxFire device with MaxBraid PE suture (Biomet Sports Medicine, Warsaw, IN); and group 8, an obliquely oriented stitch of No. 0 UHMWPE suture inserted by use of a CrossFix device (Cayenne Medical, Scottsdale, AZ). Endpoints were failure loads, failure modes, stiffness, and cyclic displacement. Mean single-pull loads were calculated for Ultra FasT-Fix (121 N), FiberWire (110 N), MaxFire (130 N), Mersilene (84 N), Orthocord (124 N), RapidLoc A2 (86 N), CrossFix (77 N), and Ultrabraid (109 N). After 500 cyclic loads, the Orthocord (222 N) repair was stronger than the others: Ultra FasT-Fix (110 N), FiberWire (117 N), MaxFire (132 N), Mersilene (89 N), RapidLoc A2 (108 N), CrossFix (95 N), and Ultrabraid (126 N) (P Fix, RapidLoc A2, and MaxFire) were comparable to the isolated UHMWPE-containing suture repairs on single-failure load testing. UHMWPE-containing suture repairs are stronger than braided polyester suture repairs, but pure UHMWPE suture (Ultrabraid) elongated more during cycling. Orthocord suture is significantly

  10. Rhinoplasty: a simplified, three-stitch, open tip suture technique. Part I: primary rhinoplasty.

    Science.gov (United States)

    Daniel, R K

    1999-04-01

    Tip suture techniques offer a reliable and dramatic method of tip modification without needing to interrupt the alar rim strip or add tip grafts. The present simplified three-stitch technique consists of the following: (1) a strut suture to fix the columella strut between the crura, (2) bilateral domal creation sutures to create tip definition, and (3) a domal equalization suture to narrow and align the domes. If required, columella septal sutures can be added; either a dorsal rotational suture or a transfixion projection suture can be used. This simplified method represents a refinement based on more than 13 years of experience with tip suture techniques. It does not require a complex operative sequence or specialized sutures. Primary indications are moderate tip deformities of inadequate definition and excessive width and certain specific tip deformities, including the parenthesis tip and nostril/tip disproportion. The primary contraindications are for patients with minor tip deformities that are best done through a closed approach and those with severe tip deformities requiring an open structure graft. The technique is simple, efficacious, and easily learned.

  11. Median sternotomy: comparative testing of braided superelastic and monofilament stainless steel sternal sutures.

    Science.gov (United States)

    Baril, Y; Brailovski, V; Chartrand, M; Terriault, P; Cartier, R

    2009-04-01

    A new device to reduce the risk of post-operative complications following median sternotomy is proposed, made of a superelastic shape memory alloy and called a braided tubular superelastic (BTS) suture. This study compares the viability of the BTS suture with that of the standard monofilament stainless steel (MSS) suture. A custom test bench was developed to perform comparative testing of the two sternal closure systems. Sternal models made of polyurethane were closed using common wiring configurations. Static and dynamic tensile separation forces, up to a maximum of 1200 N, were then applied to the closed sternums. The MSS and BTS sutures are compared in terms of the force required to open completely the sternum, the compression force at the sternum midline, and the permanent sternum opening. With a smaller sternum opening and a higher tensile separation force, the MSS suture showed greater rigidity than the BTS suture. The BTS suture, however, displayed a better capacity to reapply compression forces at the sternum midline following the repetitive application and release of tensile separation forces. These results confirm the potential of the BTS suture technology, but further studies using cadaveric sterna are needed to attest definitely to the benefits of using the BTS suture to improve bone healing.

  12. Extrusion of bone anchor suture following flexor digitorum profundus tendon avulsion injury repair.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2011-09-01

    Flexor digitorum profundus (FDP) zone I tendon avulsion injury is traditionally repaired with a pullout suture technique. More recently, bone anchor sutures have been used as a viable alternative and have largely replaced areas in hand surgery where pullout suture technique was once required. To date, there have been very few complications reported related to bone anchor suture use in FDP tendon reattachment to the bone. We report a very unusual case of extrusion of bone anchor through the nailbed, 6 years after zone I FDP tendon avulsion injury repair and a brief review of literature.

  13. Hysteresis of a biomaterial: influence of sutures and biological adhesives.

    Science.gov (United States)

    García Páez, J M; Carrera, A; Jorge, E; Millán, I; Cordón, A; Rocha, A; Maestro, M; Castillo-Olivares, J L

    2007-05-01

    We studied the changes in energy consumption of samples of calf pericardium, when joined or not joined by sutures and adhesives, by means of hysteretic cycles. Sixty-four samples were subsequently subjected to tensile stress until rupture. An overlapping suture sewn in the form of a rectangle presented an acceptable mean resistance to rupture of over 10 MPa, although lower than the mean values in an unsutured control series where the mean resistance surpassed 15 MPa. The contribution of an acrylic adhesive to the resistance to rupture was negligible. The sutured samples that were reinforced with adhesives and had not been subjected to hysteretic cycles prior to rupture showed an anisotropic behavior. This behavior appeared to be lost in all the samples that underwent hysteretic cycles. We found an inflection point in the stress/strain curve following the stepwise increase in the load, with a value greater than and proximate to the final load applied. This inflection should be analyzed by means of microscopy. Finally, the mathematical relationship between the energy consumed and the stress applied, the strain or deformation produced and the number of cycles of hysteresis to which the samples were subjected was established as the ultimate objective of this study. The bonding systems provoked a greater consumption of energy, with the greatest consumption corresponding to the first cycle in all the series assayed. An equation relating the energy consumption in a sample to the number of hysteretic cycles to which it was subjected was obtained. Its asymptote on the x-axis indicates the energy consumption for a theoretical number of cycles, making it possible to estimate the durability of the sample.

  14. Mini-open Subpectoral Biceps Tenodesis Using a Suture Anchor.

    Science.gov (United States)

    Arena, Christopher; Dhawan, Aman

    2017-10-01

    The long head of the biceps (LHB) tendon is a potential source of shoulder pain encountered by orthopaedic surgeons. A multitude of approaches to addressing LHB tendinopathy have been described. These include various surgical techniques such as tenodesis versus tenotomy, an arthroscopic versus an open approach, and differing methods of tenodesis fixation. Our preferred approach to addressing LHB tendinopathy is through a mini-open approach using a double-loaded 4.5-mm suture anchor. This Technical Note with accompanying video describes our technique for performing this procedure, as well as supporting clinical evidence and technical pearls.

  15. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  16. Neutron Detection via Bubble Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Ely, James H.; Peurrung, Anthony J.; Bond, Leonard J.; Collar, J. I.; Flake, Matthew; Knopf, Michael A.; Pitts, W. K.; Shaver, Mark W.; Sonnenschein, Andrew; Smart, John E.; Todd, Lindsay C.

    2005-10-06

    The results of a Pacific Northwest National Laboratory (PNNL) exploratory research project investigating the feasibility of fast neutron detection using a suitably prepared and operated, pressure-cycled bubble chamber are described. The research was conducted along two parallel paths. Experiments with a slow pressure-release Halon chamber at the Enrico Fermi Institute at the University of Chicago showed clear bubble nucleation sensitivity to an AmBe neutron source and insensitivity to the 662 keV gammas from a 137Cs source. Bubble formation was documented via high-speed (1000 frames/sec) photography, and the acoustic signature of bubble formation was detected using a piezo-electric transducer element mounted on the base of the chamber. The chamber’s neutron sensitivity as a function of working fluid temperature was mapped out. The second research path consisted of the design, fabrication, and testing of a fast pressure-release Freon-134a chamber at PNNL. The project concluded with successful demonstrations of the PNNL chamber’s AmBe neutron source sensitivity and 137Cs gamma insensitivity. The source response tests of the PNNL chamber were documented with high-speed photography.

  17. Visual attention in posterior stroke

    DEFF Research Database (Denmark)

    Fabricius, Charlotte; Petersen, Anders; Iversen, Helle K

    Objective: Impaired visual attention is common following strokes in the territory of the middle cerebral artery, particularly in the right hemisphere. However, attentional effects of more posterior lesions are less clear. The aim of this study was to characterize visual processing speed...... and apprehension span following posterior cerebral artery (PCA) stroke. We also relate these attentional parameters to visual word recognition, as previous studies have suggested that reduced visual speed and span may explain pure alexia. Methods: Nine patients with MR-verified focal lesions in the PCA......-territory (four left PCA; four right PCA; one bilateral, all >1 year post stroke) were compared to 25 controls using single case statistics. Visual attention was characterized by a whole report paradigm allowing for hemifield-specific speed and span measurements. We also characterized visual field defects...

  18. Classification of posterior vitreous detachment

    OpenAIRE

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2013-01-01

    Akihiro Kakehashi,1 Mikiko Takezawa,1 Jun Akiba21Department of Ophthalmology, Jichi Medical University, Saitama Medical Center, Saitama, 2Kanjodori Eye Clinic, Asahikawa, JapanAbstract: Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography...

  19. Posterior reversible encephalopathy syndrome in the emergency ...

    African Journals Online (AJOL)

    Posterior reversible encephalopathy syndrome in the emergency service. ... The most common etiologies of PRES are hypertension and renal failure, and the most frequent pathophysiology is hyperperfusion. PRES is ... Keywords: Emergency service, hyperperfusion, posterior reversible encephalopathy, vasogenic edema ...

  20. Nanotherapy for posterior eye diseases.

    Science.gov (United States)

    Kaur, Indu Pal; Kakkar, Shilpa

    2014-11-10

    It is assumed that more than 50% of the most enfeebling ocular diseases have their origin in the posterior segment. Furthermore, most of these diseases lead to partial or complete blindness, if left untreated. After cancer, blindness is the second most dreaded disease world over. However, treatment of posterior eye diseases is more challenging than the anterior segment ailments due to a series of anatomical barriers and physiological constraints confronted for delivery to this segment. In this regard, nanostructured drug delivery systems are proposed to defy ocular barriers, target retina, and act as permeation enhancers in addition to providing a controlled release. Since an important step towards developing effective treatment strategies is to understand the course or a route a drug molecule needs to follow to reach the target site, the first part of the present review discusses various pathways available for effective delivery to and clearance from the posterior eye. Promise held by nanocarrier systems, viz. liposomes, nanoparticles, and nanoemulsion, for effective delivery and selective targeting is also discussed with illustrative examples, tables, and flowcharts. However, the applicability of these nanocarrier systems as self-administration ocular drops is still an unrealized dream which is in itself a huge technological challenge. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. The CLAS drift chamber system

    CERN Document Server

    Mestayer, M D; Asavapibhop, B; Barbosa, F J; Bonneau, P; Christo, S B; Dodge, G E; Dooling, T; Duncan, W S; Dytman, S A; Feuerbach, R; Gilfoyle, G P; Gyurjyan, V; Hicks, K H; Hicks, R S; Hyde-Wright, C E; Jacobs, G; Klein, A; Klein, F J; Kossov, M; Kuhn, S E; Magahiz, R A; Major, R W; Martin, C; McGuckin, T; McNabb, J; Miskimen, R A; Müller, J A; Niczyporuk, B B; O'Meara, J E; Qin, L M; Raue, B A; Robb, J; Roudot, F; Schumacher, R A; Tedeschi, D J; Thompson, R A; Tilles, D; Tuzel, W; Vansyoc, K; Vineyard, M F; Weinstein, L B; Wilkin, G R; Yegneswaran, A; Yun, J

    2000-01-01

    Experimental Hall B at Jefferson Laboratory houses the CEBAF Large Acceptance Spectrometer, the magnetic field of which is produced by a superconducting toroid. The six coils of this toroid divide the detector azimuthally into six sectors, each of which contains three large multi-layer drift chambers for tracking charged particles produced from a fixed target on the toroidal axis. Within the 18 drift chambers are a total of 35,148 individually instrumented hexagonal drift cells. The novel geometry of these chambers provides for good tracking resolution and efficiency, along with large acceptance. The design and construction challenges posed by these large-scale detectors are described, and detailed results are presented from in-beam measurements.

  2. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  3. Holography in small bubble chambers

    International Nuclear Information System (INIS)

    Lecoq, P.

    1984-01-01

    This chapter reports on an experiment to determine the total charm cross section at different incident momenta using the small, heavy liquid bubble chamber HOBC. Holography in liquid hydrogen is also tested using the holographic lexan bubble chamber HOLEBC with the aim of preparing a future holographic experiment in hydrogen. The high intensity tests show that more than 100 incident tracks per hologram do not cause a dramatic effect on the picture quality. Hydrogen is more favorable than freon as the bubble growth is much slower in hydrogen. An advantage of holography is to have the maximum resolution in the full volume of the bubble chamber, which allows a gain in sensitivity by a factor of 10 compared to classical optics as 100 tracks per hologram look reasonable. Holograms are not more difficult to analyze than classical optics high-resolution pictures. The results show that holography is a very powerful technique which can be used in very high resolution particle physics experiments

  4. Inhibition of bone resorption by bisphosphonates interferes with orthodontically induced midpalatal suture expansion in mice.

    Science.gov (United States)

    Koehne, Till; Kahl-Nieke, Bärbel; Amling, Michael; Korbmacher-Steiner, Heike

    2018-01-18

    Craniofacial sutures are important growth sites for skull development and are sensitive to mechanical stress. In order to determine the role of bone resorption in stress-mediated sutural bone growth, midpalatal suture expansion was performed in mice receiving alendronate, an anti-resorptive bisphosphonate. The midpalatal sutures of 8-week-old C57BL/6 mice were expanded by orthodontic wires over the period of 2 weeks. Mice with maxillary expansion without drug treatment as well as untreated animals served as controls. Skulls were analyzed with micro-computed tomography (micro-CT), immunohistochemistry and histology. Maxillary expansion in mice without drug treatment resulted in an increase of TRAP-positive osteoclasts. In contrast, no increase in osteoclasts was observed in expanded sutures of mice with bisphosphonate treatment. Double calcein labeling demonstrated rapid bone formation on the oral edges of the expanded sutures in mice without bisphosphonate treatment. Less bone formation was observed in bisphosphonate-treated mice after expansion. Histology revealed that the sutural architecture was reestablished in expanded sutures of mice without bisphosphonate treatment. In contrast, the sutural architecture was disorganized and the cartilage had an irregular form, following expansion in bisphosphonate-treated mice. Finally, micro-CT imaging demonstrated that the total amount of maxillary expansion was significantly lower in mice with bisphosphonate treatment as compared to those of mice without drug treatment. In conclusion, our results indicate that osteoclast-mediated bone resorption is needed for maxillary suture expansion and reorganization of sutural architecture. Orthodontic palatal expansion can be complicated in patients with inherited or drug-induced diseases of osteoclast dysfunction.

  5. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    2010-01-01

    resolution and high sensitivity are necessary. For exact dosimetry which is done using ionization chambers (ICs), the recombination taking place in the IC has to be known. Up to now, recombination is corrected phenomenologically and more practical approaches are currently used. Nevertheless, Jaff´e's theory...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  6. Laboratory Course on Drift Chambers

    International Nuclear Information System (INIS)

    Garcia-Ferreira, Ix-B.; Garcia-Herrera, J.; Villasenor, L.

    2006-01-01

    Drift chambers play an important role in particle physics experiments as tracking detectors. We started this laboratory course with a brief review of the theoretical background and then moved on to the the experimental setup which consisted of a single-sided, single-cell drift chamber. We also used a plastic scintillator paddle, standard P-10 gas mixture (90% Ar, 10% CH4) and a collimated 90Sr source. During the laboratory session the students performend measurements of the following quantities: a) drift velocities and their variations as function of the drift field; b) gas gains and c) diffusion of electrons as they drifted in the gas

  7. Assessing suturing techniques using a virtual reality surgical simulator.

    Science.gov (United States)

    Kazemi, Hamed; Rappel, James K; Poston, Timothy; Hai Lim, Beng; Burdet, Etienne; Leong Teo, Chee

    2010-09-01

    Advantages of virtual-reality simulators surgical skill assessment and training include more training time, no risk to patient, repeatable difficulty level, reliable feedback, without the resource demands, and ethical issues of animal-based training. We tested this for a key subtask and showed a strong link between skill in the simulator and in reality. Suturing performance was assessed for four groups of participants, including experienced surgeons and naive subjects, on a custom-made virtual-reality simulator. Each subject tried the experiment 30 times using five different types of needles to perform a standardized suture placement task. Traditional metrics of performance as well as new metrics enabled by our system were proposed, and the data indicate difference between trained and untrained performance. In all traditional parameters such as time, number of attempts, and motion quantity, the medical surgeons outperformed the other three groups, though differences were not significant. However, motion smoothness, penetration and exit angles, tear size areas, and orientation change were statistically significant in the trained group when compared with untrained group. This suggests that these parameters can be used in virtual microsurgery training.

  8. Concanavalin A-induced posterior subcapsular cataract: a new model of cataractogenesis.

    Science.gov (United States)

    Gwon, A; Mantras, C; Gruber, L; Cunanan, C

    1993-12-01

    To evaluate the effect of Concanavalin A (Con A) on cataract formation in New Zealand Albino rabbits. Uveitis is a chronic inflammatory condition of the eye involving the anterior and/or posterior segments. It may be acute or chronic and is associated with the development of posterior subscapular cataract over time. Con A is a nonspecific inflammatory agent and mitogen for T cells and some B cells. Used extensively in immunogenic studies Con A has been shown to induce uveitis after intravitreal injection in New Zealand Albino rabbits. In two separate studies, Con A was injected intracamerally or intravitreally into one eye of 12 New Zealand Albino rabbits and an equal volume of balanced salt solution was injected into the opposite eye as a control. In a third study, the effect of topical steroids after intravitreal injection of Con A was evaluated. In all studies, anterior and posterior inflammation and the development of cataract was monitored by slit lamp biomicroscopy and photography. Cataract formation was also studied histopathologically. Initially, all eyes treated with Con A demonstrated moderate anterior chamber inflammation while eyes treated with balanced salt solution showed no inflammation. Three months after treatment, posterior subcapsular cataracts were present in all rabbit eyes treated with intravitreal Con A. In the third study, topical steroid treatment of Con A-induced inflammation significantly reduced anterior chamber inflammation but had no effect on vitreous humor and posterior subcapsular cataract formation. This experimental model was the first to demonstrate the development of posterior subcapsular cataracts after Con-A induced inflammation. The cataract was clinically and histologically similar to human posterior subscapular cataracts.

  9. [Prevention of surgical infection using reabsorbable antibacterial suture (Vicryl Plus) versus reabsorbable conventional suture in hernioplasty. An experimental study in animals].

    Science.gov (United States)

    Suárez Grau, Juan Manuel; De Toro Crespo, María; Docobo Durántez, Fernando; Rubio Chaves, Carolina; Martín Cartes, Juan Antonio; Docobo Pérez, Fernando

    2007-06-01

    Surgical site infections are frequent in daily surgical practice. One of the main challenges currently facing surgeons is the prevention and treatment of infections, especially those involving prosthetic material. A new suture (Vicryl Plus) has become available. In vitro studies and experimental models have demonstrated the ability of this suture to inhibit bacterial growth and consequently prevent postsurgical infection. To compare infections provoked in prosthetic implants fixed with reabsorbable conventional sutures with those in meshes fixed with reabsorbable sutures with antiseptic impregnation. Twenty white Wistar rats were used. In each rat, two hernioplasties were performed: one fixed with Vicryl Plus and the other with normal Vicryl. Subsequently, each polypropylene mesh was infected with S. aureus, and the rats remained in individual cages for a week. After 1 week, the rats were sacrificed and the meshes were extracted for macroscopic, microscopic and microbiologic study. Most of the meshes fixed with the new suture (Vicryl Plus) showed macroscopically fewer infections than those fixed with conventional suture, without abscesses and without dehiscence of the hernioplasty. In the microbiological quantitative bacterial study, the number of bacteria quantified per gram of sample was also lower in prostheses fixed with Vicryl Plus. Pathological analysis showed lesser colonization of the mesh and lower inflammatory response with Vicryl Plus than with normal Vicryl. In the statistical analysis, comparison of the medians of both groups and the interquartile ranges of microbial quantification revealed a lower infection rate in the Vicryl Plus group. The infection rate in the surgical site can be reduced by mesh fixation using the new antimicrobial suture (Vicryl Plus). We believe that this type of suture constitutes a new weapon in the fight against postoperative infection, especially in hernioplasty, emergency surgery, and dirty or potentially contaminated

  10. Pars plana vitrectomy for retinal detachment due to internal posterior ophthalmomyiasis after cataract extraction.

    Science.gov (United States)

    Billi, B; Lesnoni, G; Audisio, P; Giuliano, M A; Rossi, T; Costi, E; Stirpe, M

    1997-04-01

    The authors report a case of posterior internal ophthalmomyiasis causing vitreous haemorrhage and retinal detachment after uncomplicated cataract extraction. The patient suffered an abrupt vitreous haemorrhage 9 days after ECCE and posterior chamber IOL implantation. After 2 months the haemorrhage did not clear up and a retinal detachment arose. The patient underwent encircling scleral buckle, pars plana vitrectomy and fluid-gas exchange. In course of intervention the surgeon removed from the vitreous chamber a 14-mm-long round worm subsequently identified as a dipterous larva of the Sarcophagidae family. The patient showed no sign of subretinal tracking or retinal breaks or holes. The sclerocorneal surgical wound seems the most likely site of entrance of the parasite, and this would then be the first reported case of myiasis with no RPE tracking.

  11. Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine

    Science.gov (United States)

    Staton, Amy J.; Boyd, Christine B.

    2013-01-01

    This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…

  12. Critical Anatomy Relative to the Sacral Suture: A Postoperative Imaging Study After Robotic Sacrocolpopexy.

    Science.gov (United States)

    Crisp, Catrina C; Herfel, Charles V; Pauls, Rachel N; Westermann, Lauren B; Kleeman, Steven D

    2016-01-01

    This study aimed to characterize pertinent anatomy relative to the sacral suture placed at time of robotic sacrocolpopexy using postoperative computed tomography and magnetic resonance imaging. A vascular clip was placed at the base of the sacral suture at the time of robotic sacrocolpopexy. Six weeks postoperatively, subjects returned for a computed tomography scan and magnetic resonance imaging. Ten subjects completed the study. The middle sacral artery and vein coursed midline or to the left of midline in all the subjects. The left common iliac vein was an average of 26 mm from the sacral suture. To the right of the suture, the right common iliac artery was 18 mm away. Following the right common iliac artery to its bifurcation, the right internal iliac was on average 10 mm from the suture. The bifurcations of the inferior vena cava and the aorta were 33 mm and 54 mm further cephalad, respectively.The right ureter, on average, was 18 mm from the suture. The thickness of the anterior longitudinal ligament was 2 mm.The mean angle of descent of the sacrum was 70 degrees. Lastly, we found that 70% of the time, a vertebral body was directly below the suture; the disc was noted in 30%. We describe critical anatomy surrounding the sacral suture placed during robotic sacrocolpopexy. Proximity of both vascular and urologic structures within 10 to 18 mm, as well as anterior ligament thickness of only 2 mm highlights the importance of adequate exposure, careful dissection, and surgeon expertise.

  13. Early secondary suture versus healing by second intention of incisional abscesses

    DEFF Research Database (Denmark)

    Hermann, G G; Bagi, P; Christoffersen, I

    1988-01-01

    A controlled trial was set up to compare the treatment of wound abscesses, occurring after laparotomy, with either early secondary suture combined with cefuroxime and metronidazole given intravenously or by healing by second intention. The secondary suture was performed two days after wound...... drainage and resulted in a significant reduction (p less than 0.01) in healing time without complications. No reinfections occurred....

  14. Antibacterial-Coated Suture in Reducing Surgical Site Infection in Breast Surgery: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Enora Laas

    2012-01-01

    Full Text Available Background. To reduce the incidence of microbial colonization of suture material, Triclosan- (TC-coated suture materials have been developed. The aim of this study was to assess the incidence of suture-related complications (SRC in breast surgery with and without the use of TC-coated sutures. Methods. We performed a study on two consecutive periods: 92 patients underwent breast surgery with conventional sutures (Group 1 and 98 with TC-coated sutures (Group 2. We performed subgroups analyses and developed a model to predict SRC in Group 1 and tested its clinical efficacy in Group 2 using a nomogram-based approach. Results. The SRC rates were 13% in Group 1 and 8% in Group 2. We found that some subgroups may benefit from TC-coated sutures. The discrimination obtained from a logistic regression model developed in Group 1 and based on multifocality, age and axillary lymphadenectomy was 0.88 (95% CI 0.77–0.95 (. There was a significant difference in Group 2 between predicted probabilities and observed percentages (. The predicted and observed proportions of complications in the high-risk group were 38% and 13%, respectively. Conclusion. This study used individual predictions of SRC and showed that using TC-coated suture may prevent SRC. This was particularly significant in high-risk patients.

  15. end-to-side nerve suture - a technique to repair peripheral nerve injury

    African Journals Online (AJOL)

    Raubenheimer, Head of the Department of Oral Pathology and. Oral Biology, Faculty of Dentistry, MEDUNSA, for the meticulous histology investigations. References. 1. Mennen U. End-lo-side nerve suture in the non-human primate. Hand Surgery 1998; 3(1): 1-6. 2. Mennen U. End-to-side nerve suture in the human patient.

  16. DELPHI's Ring Imaging Cherenkov Chamber

    CERN Multimedia

    1989-01-01

    The hundreds of mirrors around this Ring Imaging Cherenkov Chamber reflect cones of light created by fast moving particles to a detector. The velocity of a particle can be measured by the size of the ring produced on the detector. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  17. Bubble chamber: colour enhanced tracks

    CERN Document Server

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  18. Testing an hydrogen streamer chamber

    CERN Multimedia

    1975-01-01

    A 2x10 cm gap streamer chamber, 35x55 cm2 in surface, was built and tested at CERN. Good tracks of cosmic rays were obtained up to atmospheric pressure, see F. Rohrbach et al, CERN-LAL (Orsay) Collaboration, Nucl. Instr. Methods 141 (1977) 229. Michel Cathenoz stand on the center.

  19. Chamber Music for Every Instrumentalist.

    Science.gov (United States)

    Latten, James E.

    2001-01-01

    Discusses why students who play musical instruments should participate in a chamber music ensemble. Provides rationale for using small ensembles in the high school band curriculum. Focuses on the topic of scheduling, illustrating how to insert small ensembles into the lesson schedule, and how to set up a new schedule. (CMK)

  20. A dual deformable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    There is disclosed an arrangement for measuring the effectiveness of a shielding material against electromagnetic fields. The arrangement comprises a first and a second reverberation chamber sharing a common wall. The common wall is partly made of the shielding material. A first antenna is arranged

  1. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  2. The Roman Bridge: a "double pulley – suture bridges" technique for rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Maffulli Nicola

    2007-12-01

    Full Text Available Abstract Background With advances in arthroscopic surgery, many techniques have been developed to increase the tendon-bone contact area, reconstituting a more anatomic configuration of the rotator cuff footprint and providing a better environment for tendon healing. Methods We present an arthroscopic rotator cuff repair technique which uses suture bridges to optimize rotator cuff tendon-footprint contact area and mean pressure. Results Two medial row 5.5-mm Bio-Corkscrew suture anchors (Arthrex, Naples, FL, which are double-loaded with No. 2 FiberWire sutures (Arthrex, Naples, FL, are placed in the medial aspect of the footprint. Two suture limbs from a single suture are both passed through a single point in the rotator cuff. This is performed for both anchors. The medial row sutures are tied using the double pulley technique. A suture limb is retrieved from each of the medial anchors through the lateral portal, and manually tied as a six-throw surgeon's knot over a metal rod. The two free suture limbs are pulled to transport the knot over the top of the tendon bridge. Then the two free suture limbs that were used to pull the knot down are tied. The end of the sutures are cut. The same double pulley technique is repeated for the other two suture limbs from the two medial anchors, but the two free suture limbs are used to produce suture bridges over the tendon, by means of a Pushlock (Arthrex, Naples, FL, placed 1 cm distal to the lateral edge of the footprint. Conclusion This technique maximizes the advantages of two techniques. On the one hand, the double pulley technique provides an extremely secure fixation in the medial aspect of the footprint. On the other hand, the suture bridges allow to improve pressurized contact area and mean footprint pressure. In this way, the bony footprint in not compromised by the distal-lateral fixation, and it is thus possible to share the load between fixation points. This maximizes the strength of the repair

  3. Hydrostatic Hyperbaric Chamber Ventilation System

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware

  4. Intracorporeal suture closure of the internal inguinal and vaginal rings in foals and horses.

    Science.gov (United States)

    Caron, John P; Brakenhoff, Jeffrey

    2008-02-01

    To report a technique for repair or prevention of inguinal hernia in horses using intracorporeal suture closure of the internal inguinal and vaginal rings. Case series. Foals (n=6) and geldings (n=2). After selection of a peri-umbilical telescope portal, instrument portals were made unilaterally or bilaterally, as needed. Herniated viscera was reduced, castration (foals) or spermatic cord remnant transection at the internal inguinal ring (adults) performed, and then simple interrupted intracorporeal sutures of synthetic absorbable suture material were used to close the internal inguinal and vaginal rings. There was no recurrence of inguinal hernia. Postoperative morbidity was minimal and cosmetic outcome was comparable to that achieved with conventional, open techniques. Laparoscopic, primary closure of the internal inguinal ring by use of intracorporeal sutures provides a secure barrier to herniation and costs considerably less than using endoscopic staples. Laparoscopic suture closure of the internal inguinal and vaginal rings provides safe and effective repair of inguinal hernia in horses.

  5. Sutures coated with antiseptic pomade to prevent bacterial colonization: a randomized clinical trial.

    Science.gov (United States)

    Cruz, Fernando; Leite, Fabiola; Cruz, Gustavo; Cruz, Silvia; Reis, Juarez; Pierce, Matthew; Cruz, Mauro

    2013-08-01

    The aim of this study was to assess if an antiseptic pomade could reduce the bacterial colonization on multifilament sutures. A randomized clinical trial was conducted with 40 volunteer patients of both sexes aged 18-70, randomly separated into experimental (n = 20) and control (n = 20) groups. The experimental group received pomade-coated sutures (iodoform + calendula) and the control group uncoated sutures. Two millimeters of the suture was harvested from each patient from the 1st to the 15th postoperative day. The bacteria that had adhered to them were cultured. The number of colony-forming units per milliliter (CFU/mL) was determined and the groups were compared using the Mann-Whitney statistical test (P antiseptic pomade was effective in reducing bacterial colonization on silk braided sutures. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Nonabsorbable-Suture-Induced Osteomyelitis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cheng Hong Yeo

    2012-01-01

    Full Text Available We are reporting a case of nonabsorbable suture-induced osteomyelitis in patient who had an open rotator cuff repair with nonabsorbable Ethibond anchor suture. Patient in this case presented with very subtle clinical features of osteomyelitis of the left proximal humerus 15 years after initial rotator cuff repair surgery. Literature had shown that deep infection following rotator cuff repairs, although rare, can be easily missed and can cause severe complications. Absorbable suture had been demonstrated to be more superior, in terms of rate of deep infection, as compared to nonabsorbable suture when used in rotator cuff repair surgery. Both absorbable and nonabsorbable suture had been demonstrated to have similar mechanical properties by several different studies. The case demonstrated that initial presentation of deep infection can be subtle and easily missed by clinicians and leads to further complications.

  7. Influence of knot configuration and tying technique on the mechanical performance of sutures.

    Science.gov (United States)

    Zimmer, C A; Thacker, J G; Powell, D M; Bellian, K T; Becker, D G; Rodeheaver, G T; Edlich, R F

    1991-01-01

    The purpose of this investigation was to determine the influence of knot configuration and tying technique on the mechanical performance of surgical sutures. Multifilament and monofilament nylon sutures were selected for this evaluation because they are commonly used in wound closure. The mechanical performance of these sutures was judged by the following parameters: knot breakage force, configuration of secure knots, and knot run down force. During each test, tension was applied at either rapid or slow rates, which correlates with the physician's speed of tying knots. On the basis of these mechanical performance tests, four throw square (1 = 1 = 1 =1) knots and five throw square (1 = 1 = 1 = 1 = 1) knots are recommended for monofilament nylon and multifilament nylon sutures, respectively, in which the speed of application of forces to the knots is relatively slow. Because these tests can easily be replicated in any laboratory, manufacturers now have a scientific basis for recommending specific tying techniques for their surgical sutures.

  8. SR and LR Union Suture for the Treatment of Myopic Strabismus Fixus: Is Scleral Fixation Necessary?

    Directory of Open Access Journals (Sweden)

    Carol P. S. Lam

    2015-01-01

    Full Text Available Purpose. To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. Methods. Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR and lateral rectus (LR with or without scleral fixation, and follow-up longer than 6 months at Hong Kong Eye Hospital from 2006 to 2013. Surgical techniques and outcomes in terms of ocular alignment are analyzed. Results. There is significant overall improvement both in postoperative angle of esodeviation (P0.05. Conclusions. Union suture of SR and LR is an effective procedure in correcting myopic strabismus fixus. Fixation of the union suture to the sclera does not improve surgical outcome.

  9. Comparison of antibacterial-coated and non-coated suture material in intraoral surgery by isolation of adherent bacteria

    Directory of Open Access Journals (Sweden)

    Klaus Pelz

    2015-09-01

    In terms of the total number of oral bacteria, and especially oral pathogens, that adhered to suture material, no reduction was demonstrated for Vicryl Plus. The use of triclosan-coated suture material offers no advantage in intraoral surgery.

  10. Huge interparietal posterior fontanel meningohydroencephalocele

    OpenAIRE

    Jorge Félix Companioni Rosildo; Manuel Filipe Dias dos Santos; Rita de Cassia de Santa Barbara

    2015-01-01

    Congenital encephalocele is a neural tube defect characterized by a sac-like protrusion of the brain, meninges, and other intracranial structures through the skull, which is caused by an embryonic development abnormality. The most common location is at the occipital bone, and its incidence varies according to different world regions. We report a case of an 1-month and 7-day-old male child with a huge interparietal-posterior fontanel meningohydroencephalocele, a rare occurrence. Physical exami...

  11. Biomechanical performance of a collagen meniscus implant with regard to suture material and irrigation fluid.

    Science.gov (United States)

    Gwinner, Clemens; von Roth, Philipp; Schmidt, Sebastian; Ode, Jan-Erik; Wulsten, Dag; Hoburg, Arnd

    2017-08-01

    The role of meniscus scaffolds remains controversial as failure rates remain high. The aim of this study was to evaluate the pullout strength of different suture materials used for fixation of the Collagen Meniscus Implant (CMI) regarding different suture materials, and type or temperature of irrigation fluid. One-hundred and twelve specimens were utilized with horizontal sutures and mounted to a dedicated test device. Loads were applied perpendicular to the CMI, until failure. Two differing suture materials - polydioxanone (PDS) and non-absorbable, braided polyester sutures (NABP) - were evaluated. Additionally, two common irrigation fluids - lactated Ringer's and electrolyte-free, hypotonic Mannitol-Sorbitol solution - were evaluated. Specimens were further evaluated according to different temperatures of the irrigation fluid. Half of the constructs were tested at room temperature (20°C) and half were evaluated at near-core body temperature (37°C). PDS sutures showed a significantly higher load-to-failure compared to NABP sutures (P=0.0008). Regarding the type of irrigation fluid, the electrolyte-free Mannitol-Sorbitol solution showed a significantly higher load-to-failure compared to the overall Ringer group (P b 0.0001). This was equivalent for both the PDS (P=0.015) and for the NABP sutures (P b 0.0001). The temperature of the irrigation fluid did not significantly influence load-to-failure. PDS sutures and electrolyte-free Mannitol-Sorbitol irrigation fluid provided the best biomechanical properties regarding load-to-failure testing. This study underlines the potential to improve construct stability for the CMI by alteration of the suture material and the type of irrigation fluid, which should be considered whenever scaffold fixation is conducted. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Mitral annuloplasty ring suture forces: Impact of surgeon, ring, and use conditions.

    Science.gov (United States)

    Pierce, Eric L; Bloodworth, Charles H; Siefert, Andrew W; Easley, Thomas F; Takayama, Tetsushi; Kawamura, Tomonori; Gorman, Robert C; Gorman, Joseph H; Yoganathan, Ajit P

    2018-01-01

    The study objective was to quantify the effect of ring type, ring-annulus sizing, suture position, and surgeon on the forces required to tie down and constrain a mitral annuloplasty ring to a beating heart. Physio (Edwards Lifesciences, Irvine, Calif) or Profile 3D (Medtronic, Dublin, Ireland) annuloplasty rings were instrumented with suture force transducers and implanted in ovine subjects (N = 23). Tie-down forces and cyclic contractile forces were recorded and analyzed at 10 suture positions and at 3 levels of increasing peak left ventricular pressure. Across all conditions, tie-down force was 2.7 ± 1.4 N and cyclic contractile force was 2.0 ± 1.2 N. Tie-down force was not meaningfully affected by any factor except surgeon. Significant differences in overall and individual tie-down forces were observed between the 2 primary implanting surgeons. No other factors were observed to significantly affect tie-down force. Contractile suture forces were significantly reduced by ring-annulus true sizing. This was driven almost exclusively by Physio cases and by reduction along the anterior aspect, where dehiscence is less common clinically. Contractile suture forces did not differ significantly between ring types. However, when undersizing, Profile 3D forces were significantly more uniform around the annular circumference. A suture's tie-down force did not correlate to its eventual contractile force. Mitral annuloplasty suture loading is influenced by ring type, ring-annulus sizing, suture position, and surgeon, suggesting that reports of dehiscence may not be merely a series of isolated errors. When compared with forces known to cause suture dehiscence, these in vivo suture loading data aid in establishing potential targets for reducing the occurrence of ring dehiscence. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Absorbable versus silk sutures for surgical treatment of trachomatous trichiasis in Ethiopia: a randomised controlled trial.

    Directory of Open Access Journals (Sweden)

    Saul N Rajak

    2011-12-01

    Full Text Available Trachoma causes blindness through an anatomical abnormality called trichiasis (lashes touching the eye. Trichiasis can recur after corrective surgery. We tested the hypothesis that using absorbable sutures instead of silk sutures might reduce the risk of recurrent disease among patients with major trichiasis in a randomised trial.1,300 individuals with major trichiasis from rural villages in the Amhara Region of Ethiopia were recruited and assigned (1:1 by computer-generated randomisation sequence to receive trichiasis surgery using either an absorbable suture (polyglactin-910 or silk sutures (removed at 7-10 days in an otherwise identical surgical technique. Participants were examined every 6 months for 2 years by clinicians masked to allocation. The primary outcome measure was recurrent trichiasis (≥one lash touching the eye at 1 year. There was no difference in prevalence of recurrent trichiasis at 1 year (114 [18.2%] in the absorbable suture group versus 120 [19.7%] in the silk suture group; odds ratio = 0.90, 95% CI 0.68-1.20. The two groups also did not differ in terms of corneal opacification, visual acuity, conjunctival inflammation, and surgical complications.There was no evidence that use of absorbable polyglactin-910 sutures was associated with a lower prevalence of trichiasis recurrence at 1 year postsurgery than silk sutures. However, from a programmatic perspective, polyglactin-910 offers the major advantage that patients do not have to be seen soon after surgery for suture removal. The postoperative review after surgery using absorbable polyglactin-910 sutures can be delayed for 3-6 months, which might allow us to better determine whether a patient needs additional surgery.ClinicalTrials.gov NCT00522860.

  14. A 3-D CT Analysis of Screw and Suture-Button Fixation of the Syndesmosis.

    Science.gov (United States)

    Schon, Jason M; Williams, Brady T; Venderley, Melanie B; Dornan, Grant J; Backus, Jonathon D; Turnbull, Travis Lee; LaPrade, Robert F; Clanton, Thomas O

    2017-02-01

    Historically, syndesmosis injuries have been repaired with screw fixation; however, some suggest that suture-button constructs may provide a more accurate anatomic and physiologic reduction. The purpose of this study was to compare changes in the volume of the syndesmotic space following screw or suture-button fixation using a preinjury and postoperative 3-D computed tomography (CT) model. The null hypothesis was that no difference would be observed among repair techniques. Twelve pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury and were subsequently repaired using 1 of 3 randomly assigned techniques: (a) one 3.5-mm cortical screw, (b) 1 suture-button, and (c) 2 suture-buttons. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were calculated to assess restoration of the native syndesmosis. Analysis of variance and Tukey's method were used to compare least squares mean differences from the intact syndesmosis among repair techniques. For each of the 3 fixation methods, the total postoperative syndesmosis volume was significantly decreased relative to the intact state. The total mean decreases in volume compared with the intact state for the 1-suture-button construct, 2-suture-button construct, and syndesmotic screw were -561 mm 3 (95% CI, -878 to -244), -964 mm 3 (95% CI, -1281 to -647) and -377 mm 3 (95% CI, -694 to -60), respectively. All repairs notably reduced the volume of the syndesmosis beyond the intact state. Fixation with 1 suture-button was not significantly different from screw or 2-suture-button fixation; however, fixation with 2 suture-buttons resulted in significantly decreased volume compared with screw fixation. The results of this study suggest that the 1-suture-button repair technique and the screw fixation repair technique were comparable for reduction of syndesmosis

  15. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    Science.gov (United States)

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P footprint displacements in group 1 (1.6 mm and 1.4 mm, respectively) were less than those in group 2 (both 3.6 mm) (P = .007 and P = .004, respectively). Mean displacement after 100 cycles for group 1 and group 2 was 2.0 mm and 3.2 mm, respectively, and at 200 cycles, mean displacement was 2.5 mm and 4.2 mm, respectively (P = .02). The mean ultimate failure load in group 1 (586 N) was greater than that in group 2 (393 N) (P = .02). The suture-tendon interface was the site of most construct failures. The suture-tape, rip-stop, double-row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or

  16. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  17. Alterações do segmento posterior na microftalmia: relato de casos Posterior segment changes in microphthalmic eyes: case report

    Directory of Open Access Journals (Sweden)

    Fernando José De Novelli

    2009-10-01

    Full Text Available Microftalmia é a alteração de desenvolvimento caracterizada pela redução do tamanho do bulbo ocular. Pode estar associada a manifestações estruturais do segmento anterior e posterior. As alterações mais comuns do segmento anterior são as opacidades corneanas, o estreitamento e fechamento do ângulo da câmara anterior e a catarata, e as mais frequentes no segmento posterior são a efusão uveal, as dobras de retina, a alteração da vascularização capilar macular, a ausência de depressão foveal e a retinosquise periférica. Este estudo descreve o caso de três pacientes com microftalmo e manifestações no segmento posterior documentadas com tomografia de coerência óptica. O primeiro caso apresentou a síndrome de efusão uveal, com descolamento de coróide e de retina, tratada com cirurgia de esclerectomia parcial nos quatro quadrantes. No segundo caso, havia a dobra retiniana neurossensorial na fóvea e feixe papilomacular em ambos os olhos sem o envolvimento de epitélio pigmentado retiniano e coriocapilar. No terceiro paciente, o microftalmo estava acompanhado de ausência da depressão foveal, cujo principal diagnóstico diferencial é a hipoplasia foveal.Microphthalmos is a developmental ocular disorder defined as a small eyeball. The condition can be associated with abnormalities of anterior and posterior segments. The most common anterior characteristics include corneal opacities, angle-closure and a shallow anterior chamber and cataract. The main findings of posterior segment are uveal effusion, retinal folds, abnormalities of macular capillar vascularization, absence of foveal depression and peripheral retinoschisis. Three patients with microphthalmos were assisted and their OCT features of posterior segment were analyzed. The first case had uveal effusion syndrome, choroidal and retinal detachment treated with parcial sclerectomy at the four quadrants. The other case presented with neurosensory retinal fold at fovea

  18. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  19. Single-incision laparoscopic splenectomy with innovative gastric traction suture

    Directory of Open Access Journals (Sweden)

    Srikanth G

    2011-01-01

    Full Text Available Laparoscopic splenectomy is now the gold standard for patients with idiopathic thrombocytopenic purpura (ITP undergoing splenectomy. There are a few reports in literature on single-incision laparoscopic (SIL splenectomy. Herein, we describe a patient undergoing SIL splenectomy for ITP without the use of a disposable port device. We report a 20-year-old female patient with steroid-refractory ITP having a platelet count of 14,000/cmm who underwent a SIL splenectomy. Dissection was facilitated by the use of a single articulating grasper and a gastric traction suture and splenic vessels were secured at the hilum with an endo-GIA stapler. She made an uneventful postoperative recovery and was discharged on the second postoperative day. She is doing well with no visible scar at 8-month follow-up.

  20. [Animal experiment study of healing of the sutured flexor tendon].

    Science.gov (United States)

    Martini, A K; Blimke, B

    1992-01-01

    The purpose of the present study was to determine whether tendons contain intrinsic cells capable of repair. To accomplish this, rabbit flexor tendons were exposed microsurgically, cut through, resutured and transferred as free transplant into the knee-joint. Immobilisation of the knee-joint will cause progressive formation of adhesions permitting neovascularisation of the transplant. Both is not observed when sutured flexor tendons were put in a knee articulation with full range of joint motion. Transmission electron micrography revealed up to 8 weeks after implantation vital cells and incidences of collagen neosynthesis independently whether adhesions existed or not. Histologically intrinsic repair was confirmed in mobile transplants and mainly initiated by cells of the visceral synovial sheet which form an anatomic-surgical unity with the tendon. In conclusion the importance of the synovial fluid for the tendon nutrition is underlined by the fact that an intrinsic healing of flexor tendon is possible without formation of adhesions.

  1. Huge interparietal posterior fontanel meningohydroencephalocele

    Directory of Open Access Journals (Sweden)

    Jorge Félix Companioni Rosildo

    2015-03-01

    Full Text Available Congenital encephalocele is a neural tube defect characterized by a sac-like protrusion of the brain, meninges, and other intracranial structures through the skull, which is caused by an embryonic development abnormality. The most common location is at the occipital bone, and its incidence varies according to different world regions. We report a case of an 1-month and 7-day-old male child with a huge interparietal-posterior fontanel meningohydroencephalocele, a rare occurrence. Physical examination and volumetric computed tomography were diagnostic. The encephalocele was surgically resected. Intradural and extradural approaches were performed; the bone defect was not primarily closed. Two days after surgery, the patient developed hydrocephaly requiring ventriculoperitoneal shunting. The surgical treatment of the meningohydroencephalocele of the interparietal-posterior fontanel may be accompanied by technical challenges and followed by complications due to the presence of large blood vessels under the overlying skin. In these cases, huge sacs herniate through large bone defects including meninges, brain, and blood vessels. The latter present communication with the superior sagittal sinus and ventricular system. A favorable surgical outcome generally follows an accurate strategy taking into account individual features of the lesion.

  2. Identification of IGF-I in the calvarial suture of young rats: histochemical analysis of the cranial sagittal sutures in a hyperthyroid rat model.

    Science.gov (United States)

    Akita, S; Hirano, A; Fujii, T

    1996-01-01

    Premature closure of cranial sutures has been known as one of the complications of juvenile or congenital hyperthyroidism. Thyroid hormone is an anabolic agent for bone formation in the early stages of childhood development. In children, excess thyroid hormone acts as an acceleration factor for the skeletal bone, whereas in adult hyperthyroidism, it causes bone mineral loss due to the high turnover rate of bone formation and consequently bone resorption. In addition, there are numerous literature descriptions concerning the interactions among bone metabolism, hormones, and growth factors, among which insulin-like growth factor I (IGF-I) is the most abundantly found growth factor in osteoblasts and in bone models in vivo. We therefore investigated whether or not the cranial sutures show accelerated closure and how the local growth factors or cytokines participate and function in local bone metabolism after administration of exogenous excess thyroid hormone in a rat model. A total of 60 female Wistar rats, aged 10 days, were divided into two groups, the triiodothyronine (T3)-treated group (n = 30, T3 0.1 microgram/gm of body weight per day) and the control group (n = 30, saline vehicle only), and were maintained and subsequently sacrificed at 15, 30, and 60 days. The parameters of cranial width derived from the morphologic measurements of the skull indicated that the lambda-asterion distance at 30 days and the pterion-bregma distance at 60 days in the T3-treated group were significantly decreased compared with those of the control group. Furthermore, the fluorescent histologic findings showed fluorescent labeling with no interruption along the suture edges, suggesting continuous bone formation, and displayed narrowing of the suture gap of the sagittal suture in the T3-treated group. Tartrate resistant acid phosphatase staining showed very little osteoclastic activity in the sagittal suture, especially in the T3-treated group. The intensity of immunohistochemical

  3. The Role of Epimysium in Suturing Skeletal Muscle Lacerations

    Science.gov (United States)

    2005-01-01

    repair.12 Longer immobiliza- tion leads to inferior healing, atrophy , scarring, longer recovery times, and increased risk of rerupture.12 A bet- ter...Wien) 1995;133:195– 200. 24. Lin JT, Nagler W. Partial tear of the posterior deltoid muscle in an elderly woman. Clin J Sport Med 2003;13:120–121. 25

  4. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting

    Directory of Open Access Journals (Sweden)

    Jin-Soo Kim

    2018-02-01

    Full Text Available AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG laser posterior capsulotomy with vitreous strand cutting METHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern. The best corrected visual acuity (BCVA, intraocular pressure (IOP, refractive error, endothelial cell count (ECC, anterior segment parameters, including anterior chamber depth (ACD and anterior chamber angle (ACA were measured before and 1mo after the laser posterior capsulotomy. RESULTS: In both groups, the BCVA improved significantly (P<0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group; the IOP and ECC did not significantly change. The ACD significantly decreased (P<0.001 for both and the ACA significantly increased (P=0.001 for the modified round pattern group and P=0.034 for the cruciate group. The extent of changes in these parameters was not significantly different between the groups. CONCLUSION: Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  5. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  6. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  7. Development of multiwire proportional chambers

    CERN Document Server

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  8. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  9. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material.

    Science.gov (United States)

    Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M

    2008-11-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.

  10. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London......-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were...

  11. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  12. GBO RF Anechoic Chamber & Antenna Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  13. Displaced avulsion fractures of the posterior cruciate ligament: Treated by stellate steel plate fixation.

    Science.gov (United States)

    Li, Lijun; Tian, Wei

    2015-01-01

    The open reduction with internal fixation is an effective approach for treatment of avulsion fracture of posterior cruciate ligament. The previously used internal fixation materials including hollow screws, absorbable screw, tension bands and sutures have great defects such as insufficient fixation strength, susceptibility to re-fracture, etc. Stellate steel plate is novel material for internal fixation which has unique gear-like structure design. We used stellate steel plate for treatment of displaced avulsion fractures of posterior cruciate ligament in this study. 14 patients (9 men, 5 women; aged, 19-35 years; mean age, 28 years) with displaced avulsion fractures of the tibial insertion of the posterior cruciate ligament were retrospectively analyzed between June 2009 and June 2011. The mean duration from injury to the operation was 8.3 days (range 6-15 days). All the patients were treated with open reduction and internal fixation of a stellate steel plate (DePuy, Raynham, MA 02767, USA). The Lysholm-Tegner knee function score criteria were used to analyze results. The mean followup was 24.6 months (range 18-32 months). After 6 months, all the fractures healed and knee joint activity was normal, with no knee stiffness or instability. The Lysholm-Tegner scores were 97.1 ± 1.7 points at the final followup. Owing to its unique gear structure, the stellate steel plate design can effectively fix an avulsion fracture block and it is a simple operation with short postoperative rehabilitation time and firm fixation.

  14. Comparison of two different suture-passing techniques with different suture materials and thicknesses: Biomechanical study of flexor tendons for yield points, gap formation and early post-operative status

    Directory of Open Access Journals (Sweden)

    Volkan Ergan

    2016-12-01

    Conclusion: The yield points with higher forces is expected to be preferred, but their thicknesses can be 3-0 or 4-0. Oblique suture passing should be preferred rather than longitudinal passing. Obviously, suture strengthening methods, like epitendineous running sutures and core sutures, should be used. Without these measures, even passive wrist motion can result in gap formation at the repair site. The results of this study showed that tensile properties of the repaired vary considerably with differences in suture material and design. [Hand Microsurg 2016; 5(3.000: 130-136

  15. Basic interrupted versus continuous suturing techniques in bronchial anastomosis following sleeve lobectomy in dogs.

    Science.gov (United States)

    Bayram, Ahmet Sami; Erol, Mehmet Muharrem; Salci, Hakan; Ozyiğit, Ozgür; Görgül, Sacit; Gebitekin, Cengiz

    2007-12-01

    Sleeve resection with or without lung resection is a valid conservative operation for patients with benign or malignant tumors; it enables the preservation of lung parenchyma. The aim of this prospective randomized study was to compare complications, operating time, and bronchial healing between the techniques of interrupted and continuous suturing for bronchial anastomosis in dogs. Twenty adult mongrel dogs each weighing 18-22 kg (average: 20 kg) were divided into two groups according to the anastomosis technique performed: group A, interrupted suturing and group B, continuous suturing. Each group comprised of 10 dogs. Following right thoracotomy, sleeve resection of the right cranial lobe was performed in all dogs. Basic interrupted sutures using 4/0 Vicryl (Ethicon, USA) were used in group A, and continuous sutures were used in group B. The median anastomosis time was 15.2 min (range: 13-21 min) in group A and 9.6 min (range: 8-13 min) in group B. In all dogs, the anastomosis line was resected via right pneumonectomy for histopathological investigation 1 month after sleeve resection. Histopathological examination revealed that the healing of the anastomosis was not affected by the suturing technique applied. One dog from each group died on the fourth postoperative day; Fisher's exact test, p=0.763. Our research revealed that the healing of the anastomosis was not affected by the suturing technique performed.

  16. Effectiveness of ultrasonographic evaluation of the cranial sutures in children with suspected craniosynostosis

    International Nuclear Information System (INIS)

    Simanovsky, Natalia; Hiller, Nurith; Koplewitz, Benjamin; Rozovsky, Katya

    2009-01-01

    Computed tomography (CT) is the 'gold standard' for evaluation of the cranial sutures. While prenatal cranial suture evaluation with ultrasound (US) is common, US has not been established as a postnatal screening tool. We evaluated the effectiveness of US for diagnosis of craniosynostosis (CS). During 2006, 24 infants with questionable CS were assessed with US of the sagittal, metopic, and bilateral coronal and lambdoid sutures. US findings and clinical records were reviewed retrospectively. Sixteen boys and eight girls (ages 1-11 months, mean 4.3) underwent US. The correct diagnosis was provided in 23 (95%), with equivocal findings in one patient. Cranial sutures appeared normal in 15 infants, who had normal clinical presentation at mean 5.8 months follow-up; CT confirmation was obtained in two. In eight children, US identified premature closure of one or more cranial sutures. Three-dimensional CT was performed as a preparation for surgery in four, with classical CS findings. In one case with inconclusive US findings, CT showed narrow but open sutures. Sonographic examination of cranial sutures may serve as a first imaging tool for evaluation of craniosynostosis. CT may be reserved for children with abnormal or equivocal ultrasound and for preoperative planning. (orig.)

  17. Effectiveness of ultrasonographic evaluation of the cranial sutures in children with suspected craniosynostosis

    Energy Technology Data Exchange (ETDEWEB)

    Simanovsky, Natalia; Hiller, Nurith; Koplewitz, Benjamin; Rozovsky, Katya [Hadassah Hebrew University Medical Center, Department of Medical Imaging, Mount, Scopus, P.O. Box 24035, Jerusalem (Israel)

    2009-03-15

    Computed tomography (CT) is the 'gold standard' for evaluation of the cranial sutures. While prenatal cranial suture evaluation with ultrasound (US) is common, US has not been established as a postnatal screening tool. We evaluated the effectiveness of US for diagnosis of craniosynostosis (CS). During 2006, 24 infants with questionable CS were assessed with US of the sagittal, metopic, and bilateral coronal and lambdoid sutures. US findings and clinical records were reviewed retrospectively. Sixteen boys and eight girls (ages 1-11 months, mean 4.3) underwent US. The correct diagnosis was provided in 23 (95%), with equivocal findings in one patient. Cranial sutures appeared normal in 15 infants, who had normal clinical presentation at mean 5.8 months follow-up; CT confirmation was obtained in two. In eight children, US identified premature closure of one or more cranial sutures. Three-dimensional CT was performed as a preparation for surgery in four, with classical CS findings. In one case with inconclusive US findings, CT showed narrow but open sutures. Sonographic examination of cranial sutures may serve as a first imaging tool for evaluation of craniosynostosis. CT may be reserved for children with abnormal or equivocal ultrasound and for preoperative planning. (orig.)

  18. Immunostimulatory sutures that treat local disease recurrence following primary tumor resection

    Energy Technology Data Exchange (ETDEWEB)

    Intra, Janjira; Zhang Xueqing; Salem, Aliasger K [Division of Pharmaceutics, College of Pharmacy, University of Iowa, Iowa City, IA 52242 (United States); Williams, Robin L; Zhu Xiaoyan [Department of Surgery, Roy J and Lucille Carver College of Medicine, University of Iowa, Iowa City, IA 52242 (United States); Sandler, Anthony D, E-mail: aliasger-salem@uiowa.edu [Department of Surgery and Center for Cancer and Immunology Research, Children' s National Medical Center, Washington DC 20010 (United States)

    2011-02-15

    Neuroblastoma is a common childhood cancer that often results in progressive minimal residual disease after primary tumor resection. Cytosine-phosphorothioate-guanine oligonucleotides (CpG ODN) have been reported to induce potent anti-tumor immune responses. In this communication, we report on the development of a CpG ODN-loaded suture that can close up the wound following tumor excision and provide sustained localized delivery of CpG ODN to treat local disease recurrence. The suture was prepared by melt extruding a mixture of polylactic acid-co-glycolic acid (PLGA 75:25 0.47 dL g{sup -1}) pellets and CpG ODN 1826. Scanning electron microscopy images showed that the sutures were free of defects and cracks. UV spectrophotometry measurements at 260 nm showed that sutures provide sustained release of CpG ODN over 35 days. Syngeneic female A/J mice were inoculated subcutaneously with 1 x 10{sup 6} Neuro-2a murine neuroblastoma wild-type cells and tumors were grown between 5 to 10 mm before the tumors were excised. Wounds from the tumor resection were closed using CpG ODN-loaded sutures and/or polyglycolic acid Vicryl suture. Suppression of neuroblastoma recurrence and mouse survival were significantly higher in mice where wounds were closed using the CpG ODN-loaded sutures relative to all other groups. (communication)

  19. Mechanical properties of commercially available nylon sutures in the United States.

    Science.gov (United States)

    Callahan, Travis L; Lear, William; Kruzic, Jamie J; Maughan, Cory B

    2017-05-01

    Surgeons can choose from a wide selection of commercially available suture brands, which come at a range of prices. There is currently limited evidence in the literature to guide this selection process. This investigation examined the breaking force, stress, and elongation of a variety of commercially available nylon sutures compared to their relative prices. Seven 5-0, nonabsorbable, nylon suture brands were tensile tested in straight, knotted and knot-security configurations according to the procedures outlined by the United States Pharmacopeia for the tensile testing of sutures. Covidien, the cheapest brand tested, had the highest failure load of straight and knot-security tests. Dafilon was found to have the highest breaking force and percent elongation of knot-pull tests. J&J Ethicon and Supramid had the highest percent elongation to failure for straight-pull and knot-security tests, respectively. This study was limited to specific in vitro tensile properties of nylon suture. Other factors affecting suture quality and price, such as needle properties, were not investigated. The data presented in the study provide information for guiding the selection and purchase of sutures according to tensile properties. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 815-819, 2017. © 2016 Wiley Periodicals, Inc.

  20. Introduction of a New Suture Method in Repair of Peripheral Nerves Injured with a Sharp Mechanism

    Directory of Open Access Journals (Sweden)

    Alireza Saied

    2015-09-01

    Full Text Available Background: The standard method for repair of an injured peripheal nerve is epineural repair with separate sutures. Herein we describe a method in which the nerve is sutured with continous sutures. In fact this method has not been utilized for nerve repair previously and our purpose was to compare it to the standard method. If it proved to be successful it would replace the standard method in certain circumstances. Methods: The proposal of the clinical trial was given a reference number form the ethics comitee. 25 dogs in which the scaitic nerve was cut by a sharp blade under genaeral anesthesia were divided randomly into three groups: control (5 dogs, repair of sciatic nerve with simple sutures (10 and repair with continous sutures (10. In the control group the nerve was not repaired at all. After 6 weeks the dogs were killed and the nerve was studied by light and electronic microscopes. The amount of consumed suture material, time of repair, myelin thickness and axon diiameter were examined. Ultrastructural studies were performed to assess degeneration and regeneration findings. Results: Time of repair and the amount of consumed suture material were significantly lower in the continous group (P

  1. [An experimental assessment of methods for applying intestinal sutures in intestinal obstruction].

    Science.gov (United States)

    Akhmadudinov, M G

    1992-04-01

    The results of various methods used in applying intestinal sutures in obturation were studied. Three series of experiments were conducted on 30 dogs--resection of the intestine after obstruction with the formation of anastomoses by means of double-row suture (Albert--Shmiden--Lambert) in the first series (10 dogs), by a single-row suture after V. M. Mateshchuk [correction of Mateshuku] in the second series, and bu a single-row stretching suture suggested by the author in the third series. The postoperative complications and the parameters of physical airtightness of the intestinal anastomosis were studied in dynamics in the experimental animals. The results of the study: incompetence of the anastomosis sutures in the first series 6, in the second 4, and in the third series one. Adhesions occurred in all animals of the first and second series and in 2 of the third series. Six dogs of the first series died, 4 of the second, and one of the third. Study of the dynamics of the results showed a direct connection of the complications with the parameters of the physical airtightness of the anastomosis, and the last-named with the method of the intestinal suture. Relatively better results were noted in formation of the anastomosis by means of our suggested stretshing continuous suture passed through the serous, muscular, and submucous coats of the intestine.

  2. Triclosan-coated sutures and sternal wound infections: a prospective randomized clinical trial.

    Science.gov (United States)

    Steingrimsson, S; Thimour-Bergström, L; Roman-Emanuel, C; Scherstén, H; Friberg, Ö; Gudbjartsson, T; Jeppsson, A

    2015-12-01

    Surgical site infection is a common complication following cardiac surgery. Triclosan-coated sutures have been shown to reduce the rate of infections in various surgical wounds, including wounds after vein harvesting in coronary artery bypass grafting patients. Our purpose was to compare the rate of infections in sternotomy wounds closed with triclosan-coated or conventional sutures. A total of 357 patients that underwent coronary artery bypass grafting were included in a prospective randomized double-blind single-center study. The patients were randomized to closure of the sternal wound with either triclosan-coated sutures (Vicryl Plus and Monocryl Plus, Ethicon, Inc., Somerville, NJ, USA) (n = 179) or identical sutures without triclosan (n = 178). Patients were followed up after 30 days (clinical visit) and 60 days (telephone interview). The primary endpoint was the prevalence of sternal wound infection according to the Centers for Disease Control and Prevention (CDC) criteria. The demographics in both groups were comparable, including age, gender, body mass index, and rate of diabetes and smoking. Sternal wound infection was diagnosed in 43 patients; 23 (12.8%) sutured with triclosan-coated sutures compared to 20 (11.2%) sutured without triclosan (p = 0.640). Most infections were superficial (n = 36, 10.1%), while 7 (2.0%) were deep sternal wound infections. There were 16 positive cultures in the triclosan group and 17 in the non-coated suture group (p = 0.842). The most commonly identified main pathogens were Staphylococcus aureus (45.4%) and coagulase-negative staphylococci (36.4%). Skin closure with triclosan-coated sutures did not reduce the rate of sternal wound infection after coronary artery bypass grafting. (clinicaltrials.gov: NCT01212315).

  3. Triclosan-coated sutures reduce wound infections after spinal surgery: a retrospective, nonrandomized, clinical study.

    Science.gov (United States)

    Ueno, Masaki; Saito, Wataru; Yamagata, Megumu; Imura, Takayuki; Inoue, Gen; Nakazawa, Toshiyuki; Takahira, Naonobu; Uchida, Kentaro; Fukahori, Nobuko; Shimomura, Kiyomi; Takaso, Masashi

    2015-05-01

    Surgical site infection (SSI) is a serious postoperative complication. The incidence of SSIs is lower in clean orthopedic surgery than in other fields, but it is higher after spinal surgery, reaching 4.15% in high-risk patients. Several studies reported that triclosan-coated polyglactin 910 sutures (Vicryl Plus; Ethicon, Inc., Somerville, NJ, USA) significantly reduced the infection rate in the general surgical, neurosurgical, and thoracic surgical fields. However, there have been no studies on the effects of such coated sutures on the incidence of SSIs in orthopedics. To compare the incidence of wound infections after spinal surgery using triclosan-coated suture materials with that of noncoated ones. A retrospective, nonrandomized, and clinical study. From May 2010 to April 2012, 405 patients underwent a spinal surgical procedure in the Department of Orthopedic Surgery of two university hospitals. The primary outcome was the number of wound infections and dehiscences. Two hundred five patients had a conventional wound closure with polyglactin 910 suture (Vicryl) between May 2010 and April 2011 (Time Period 1 [TP1]), and 200 patients underwent wound closure with triclosan-coated polyglactin 910 suture (Vicryl Plus) between May 2011 and April 2012 (TP2). Statistical comparisons of wound infections, dehiscence, and risk factors for poor wound healing or infection were performed. None of the authors has any conflict of interest associated with this study. There were two cases of wound dehiscence in TP1 and one in TP2 (p=.509). Using noncoated sutures in TP1, eight patients (3.90%) had wound infections, whereas one patient (0.50%) had wound infections in TP2 (using triclosan-coated sutures); the difference was significant (p=.020). The use of triclosan-coated polyglactin 910 sutures instead of polyglactin 910 sutures may reduce the number of wound infections after spinal surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  5. Vacuum chamber at intersection I-6

    CERN Multimedia

    1971-01-01

    The vacuum chamber at intersection region I-6, one of these where experiments in colliding-beam physics will be taking place. The "wheels" prevent the thin wall (1.5 mm) of the chamber from collapsing. The chamber is equipped with heating tapes and its wrapped in thermal insulation. Residual gas pressure at this and other similar regions is around 10_11.

  6. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  7. Vacuum chamber for an undulator straight section

    International Nuclear Information System (INIS)

    Kim, S.; Wehrle, R.; Genens, L.

    1987-01-01

    A prototype aluminum extruded vacuum chamber for an undulator straight section of the Advanced Photon Source is described. The 52.-m long vacuum system is designed so that the undulator gap variation does not interfere with it. The chamber is gripped in a stiff close toleranced mounting structure to insure dimensional tolerance of the chamber height

  8. Posterior ankle impingement in the dancer.

    Science.gov (United States)

    Moser, Brad R

    2011-01-01

    Dancers spend a lot of time in the relevé position in demi-pointe and en pointe in their training and their careers. Pain from both osseous and soft tissue causes may start to occur in the posterior aspect of their ankle. This article reviews the potential causes of posterior ankle impingement in dancers. It will discuss the clinical evaluation of a dancer and the appropriate workup and radiographic studies needed to further evaluate a dancer with suspected posterior ankle impingement.

  9. Proportional chambers and multiwire drift chambers at high rates

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1977-01-01

    The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem

  10. Pterygoid implant for atrophic posterior maxilla

    Directory of Open Access Journals (Sweden)

    V R Balaji

    2017-01-01

    Full Text Available Replacement of missing teeth in the posterior maxilla is always a challenge for the treating implant surgeon as the posterior maxilla has several obstacles in the form of quality, quantity, the anatomy of the maxillary sinus, and inaccessibility. To overcome these deficiencies, several surgical procedures such as sinus lift, bone augmentation, tilted implants, short implants, and zygomatic implants were tried. Since these procedures have their own limitations, pterygomaxillary region provides us an excellent place for placement of implant and rehabilitation of posterior maxilla. This case report describes the usage of the pterygomaxillary region for placement of the implant to restore atrophic posterior maxilla, without any additional surgical procedures.

  11. Brief communication: age and fractal dimensions of human sagittal and coronal sutures

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Jacobsen, Jens Christian Brings

    2003-01-01

    The fractal dimensions of human sagittal and coronal sutures were calculated on 31 complete skulls from the Terry Collection. The aim was to investigate whether the fractal dimension, relying on the whole sutural length, might yield a better description of age-related changes in sutural morphology......, as opposed to other methods of quantification, which generally rely on more arbitrary scoring systems. However, the fractal dimension did not yield better age correlations than other previously described methods. At best, the results reflected the general observation that young adults below age 40 years...

  12. Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor

    Science.gov (United States)

    Erickson, John; Chiarappa, Frank; Haskel, Jonathan; Rice, Justin; Hyatt, Adam; Monica, James; Dhawan, Aman

    2017-01-01

    Background: All–soft tissue suture anchors provide advantages of decreased removal of bone and decreased glenoid volume occupied compared with traditional tap or screw-in suture anchors. Previous published data have led to biomechanical concerns with the use of first-generation all-soft suture anchors. Purpose/Hypothesis: The purpose of this study was to evaluate the load to 2-mm displacement and ultimate load to failure of a second-generation all-soft suture anchor, compared with a first-generation anchor and a traditional PEEK (polyether ether ketone) anchor. The null hypothesis was that the newer second-generation anchor will demonstrate no difference in loads to 2-mm displacement after cycling compared with first-generation all-soft suture anchors. Study Design: Controlled laboratory study. Methods: Twenty human cadaveric glenoids were utilized to create 97 total suture anchor sites, and 1 of 3 anchors were randomized and placed into each site: (1) first-generation all-soft suture anchor (Juggerknot; Biomet), (2) second-generation all-soft suture anchor (Suturefix; Smith & Nephew), and (3) a control PEEK anchor (Bioraptor; Smith & Nephew). After initial cyclic loading, load to 2 mm of displacement and ultimate load to failure were measured for each anchor. Results: After cyclic loading, the load to 2-mm displacement was significantly less in first-generation anchors compared with controls (P .05). Conclusion: The newer generation all-soft suture anchors with a theoretically more rigid construct and deployment configuration demonstrate biomechanical characteristics (specifically, with load to 2-mm displacement after cyclic loading) that are improved over first-generation all-soft suture anchors and similar to a traditional solid tap-in anchor. The configuration of these newer generation all-soft suture anchors appears to mitigate the biomechanical concerns of decreased load to failure with first-generation all–soft tissue suture anchors. Clinical Relevance

  13. A new, removable, sliding noose for adjustable-suture strabismus surgery.

    Science.gov (United States)

    Deschler, Emily K; Irsch, Kristina; Guyton, Kristina L; Guyton, David L

    2013-10-01

    We describe a new removable sliding polyglactin 910 suture noose for postoperative suture adjustment following extraocular muscle surgery. No excess suture material remains after adjustment has been completed, helping to reduce discomfort, inflammation, and scarring. We have used this noose with the cul-de-sac conjunctival incision in approximately 360 patients over a period of 18 months. This report details how to fashion, use, and remove the noose. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  14. Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses.

    Science.gov (United States)

    Baumgartner, N; Dobrin, P B; Morasch, M; Dong, Q S; Mrkvicka, R

    1996-05-01

    Experiments were performed in dogs to evaluate the mechanics of 26 end-to-end and 42 end-to-side artery-vein graft anastomoses constructed with continuous polypropylene sutures (Surgilene; Davis & Geck, Division of American Cyanamid Co., Danbury, Conn.), continuous polybutester sutures (Novafil; Davis & Geck), and interrupted stitches with either suture material. After construction, the grafts and adjoining arteries were excised, mounted in vitro at in situ length, filled with a dilute barium sulfate suspension, and pressurized in 25 mm Hg steps up to 200 mm Hg. Radiographs were obtained at each pressure. The computed cross-sectional areas of the anastomoses were compared with those of the native arteries at corresponding pressures. Results showed that for the end-to-end anastomoses at 100 mm Hg the cross-sectional areas of the continuous Surgilene anastomoses were 70% of the native artery cross-sectional areas, the cross-sectional areas of the continuous Novafil anastomoses were 90% of the native artery cross-sectional areas, and the cross-sectional areas of the interrupted anastomoses were 107% of the native artery cross-sectional areas (p anastomoses demonstrated no differences in cross-sectional areas or compliance for the three suture techniques. This suggests that, unlike with end-to-end anastomoses, when constructing an end-to-side anastomosis in patients any of the three suture techniques may be acceptable.

  15. Occiput posterior position diagnosis: vaginal examination or intrapartum sonography? A clinical review.

    Science.gov (United States)

    Malvasi, A; Tinelli, A; Barbera, A; Eggebø, T M; Mynbaev, O A; Bochicchio, M; Pacella, E; Di Renzo, G C

    2014-03-01

    The occiput posterior (OP) position is one of the most frequent malposition during labor. During the first stage of labor, the fetal head may stay in the OP position in 30% of the cases, but of these only 5-7% remains as such at time of delivery. The diagnosis of OP position in the second stage of labor is made difficult by the presence of the caput succedaneum or scalp hair, both of which may give some problem in the identification of fetal head sutures and fontanels and their location in relationship to maternal pelvic landmarks. The capability of diagnosing a fetus in OP position by digital examination has been extremely inaccurate, whereas an ultrasound approach, transabdominal, transperineal and transvaginal, has clearly shown its superior diagnostic accuracy. This is true not only for diagnosis of malpositions, detected in both first and second stage of labor, but also in cases of marked asynclitism.

  16. The use of veritas collagen matrix to reconstruct the posterior chest wall after costovertebrectomy.

    Science.gov (United States)

    Rocco, Gaetano; Serra, Luca; Fazioli, Flavio; Mori, Stefano; Mehrabi-Kermani, Farrokh; Capasso, Agostino; Martucci, Nicola; La Rocca, Antonello; Apice, Gaetano

    2011-07-01

    Among the new materials introduced for chest wall reconstruction, the use of collagen matrix is gaining increasing favor for its biomechanical properties. We describe the reconstruction of the chest wall with Veritas (Synovis, St Paul, MN) collagen matrix of a posterior chest wall defect after costovertebrectomy for Ewing's sarcoma. En bloc resection was performed, including partial D7 through D9 vertebrectomy along with the posterolateral segments of corresponding ribs. The collagen matrix patch was sutured to the spine stabilizer and the surrounding rib segments and was covered by previously raised latissimus dorsi and trapezius muscle flaps. Excellent stabilization was obtained. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Study on the tribological behavior of surgical suture interacting with a skin substitute by using a penetration friction apparatus.

    Science.gov (United States)

    Zhang, Gangqiang; Ren, Tianhui; Zhang, Sheng; Zeng, Xiangqiong; van der Heide, Emile

    2018-02-01

    Surgical sutures have different sizes, structures, whereas they are being used for various surgeries. The high friction performance of surgical sutures in the suturing process may cause inflammation and pain, leading to a longer recovery time. This paper presents an understanding of the tribological behavior of surgical suture with monofilament and multifilament structures, by means of a penetration friction apparatus (PFA). The results indicated that structure and surface topography of the surgical suture had a pronounced effect on the tribological interactions. It was found that the friction force and abrasion area of skin substitute with the penetration of polyglycolic acid (PGA) multifilament surgical suture were larger than that of Nylon monofilament surgical suture. Meanwhile, more abrasion at the pull-in boundary of skin substitute was observed compared with that at the pull-out boundary. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Fixation in laparoscopic incisional hernia repair: Suture versus tacks

    Directory of Open Access Journals (Sweden)

    Adil Bangash

    2013-01-01

    Full Text Available Aims and Objectives: To compare the frequency of complications of laparoscopic repair of incisional hernia using fixation of mesh with transabdominal sutures tacks. Materials and Methods: This study was conducted as part of an interventional multicenter trial at the Rehman Medical Institute, Peshawar, Peshawar Institute of Medical Sciences, and Pakistan Institute of Medical Science, Islamabad, from the 1 st of November 2008 till 31 st October 2011. The frequency of complications was calculated as the measure of comparing two methods of fixation in laparoscopic repair of incisional hernia using the IPOM technique. These patients were admitted via the outpatient department and their demographic data were collected on a pro forma basis. Forty-five patients were alternately placed in either group, and group I comprised patients with a ventral hernia that was fixed using spiral tacks whereas the other group was fixed with transabdominal sutures. A polytetraflouroethylene (Dual R mesh was applied in all cases. All data were collected onthe individual pro forma of each patient and was loaded on the SPSS R version 13.0. Results: The BMI in both groups was similar (P=0.94 The mean hospital stay was higher in the PTFE mesh group but the values were not significant (P=1.22.No perioperative death was observed in either group. One patient (2.2% from group I was readmitted with varying complaints and was diagnosed as having subacute intestinal obstruction (P>0.05. A higher but insignificant recurrence rate was observed in the polyester group over a one-year period of follow-up. Three patients (6.6% were diagnosed with recurrences in group I. Instead the PTFE group had a similar recurrence rate recurrence (P=1.00. Conclusion: The rate of recurrence in this study showed no significant difference by either mode of fixation. But statistically significant pain scores and increased operative time to fixation favors the use of tacks that limits to the few inner

  19. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  20. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    conditions, and the environment can be carefully controlled and easily changed. The protocols in this unit include construction of the flow chamber and the bubble trap, assembly and sterilization of the flow chamber system, inoculation of the flow chambers, running of the system, image capture and analysis......This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  1. TRU waste characterization chamber gloveboxes

    International Nuclear Information System (INIS)

    Duncan, D. S.

    1998-01-01

    Argonne National Laboratory-West (ANL-W) is participating in the Department of Energy's (DOE) National Transuranic Waste Program in support of the Waste Isolation Pilot Plant (WIPP). The Laboratory's support currently consists of intrusive characterization of a selected population of drums containing transuranic waste. This characterization is performed in a complex of alpha containment gloveboxes termed the Waste Characterization Gloveboxes. Made up of the Waste Characterization Chamber, Sample Preparation Glovebox, and the Equipment Repair Glovebox, they were designed as a small production characterization facility for support of the Idaho National Engineering and Environmental Laboratory (INEEL). This paper presents salient features of these gloveboxes

  2. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    1979-05-01

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  3. Gnathostomiasis of the anterior chamber

    Directory of Open Access Journals (Sweden)

    Barua P

    2007-01-01

    Full Text Available Ocular involvement with Gnathostoma spinigerum occurs years after the initial infection that is acquired by ingestion of poorly cooked, pickled seafood or water contaminated with third stage larvae. Here we report a case of gnathostomiasis of the left eye of a 32-year-old lady hailing from Meghalaya, India. Her vision had deteriorated to hand movement. Slit lamp examination revealed a live, actively motile worm in the anterior chamber, which was extracted by supra temporal limbal incision and visual acuity was restored.

  4. Experimental work on drift chambers

    International Nuclear Information System (INIS)

    Alcaraz, J.; Duran, I.; Gonzalez, E.; Martinez-Laso, L.; Olmos, P.

    1989-01-01

    An experimental work made on drift chambers is described in two chapters. In the firt chapter we present the description of the experimental installation used, as well as some details on the data adquisition systems and the characteristics on three ways used for calibration proposes (cosmic muons, β radiation and test beam using SPS at CERN facilities). The second chapter describes the defferent prototypes studied. The experimental set up and the analysis are given. Some results are discussed. The magnetic field effect is also studied. (Author)

  5. Comparison of surgical time and complication rate of subcutaneous and skin closure using barbed suture or traditional knotted suture in dogs.

    Science.gov (United States)

    Nutt, Laura K; Wilson, Megan L; Sakals, Sherisse

    2017-12-01

    This prospective study evaluated the handling, intraoperative and postoperative complication rates of a barbed knotless suture for closure of subcutaneous tissue and skin in 17 client-owned dogs (group A) following a tibial plateau leveling osteotomy procedure. Clinical characteristics, surgical time, and complication rates were compared to a control group of 17 client-owned dogs (group B) with subcutaneous tissue and skin closure using traditional suture material. Signalment was not significantly different between groups and did not have an effect on complication rates. Surgical times were not significantly different for subcutaneous tissue or skin closure between the 2 groups. There were significantly more intraoperative complications in the barbed suture group (A: 4/17; B: 0/17; P = 0.033) but no difference in minor or major postoperative complication rates (minor A: 2/16; B: 1/14; P = 0.626, major A: 2/16; B: 0/14; P = 0.171).

  6. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  7. Shape memory alloy fixator system for suturing tissue in minimal access surgery.

    Science.gov (United States)

    Xu, W; Frank, T G; Stockham, G; Cuschieri, A

    1999-01-01

    A new technique for suturing human tissue is described in which tissue closure is achieved by means of small fixators made from shape memory alloy. The aim of the development is to provide an alternative to thread suturing in minimal access surgery, which is quicker and requires less skill to achieve the required suturing quality. The design of the fixators is described in terms of the thermal shape recovery of shape memory alloy and a novel form of finite element analysis, which uses a nonlinear elastic element for the material property. Thermal analysis of the fixators and surrounding tissue is used to predict the temperature distribution during and after the application of electric current heating. This was checked in an in vitro experiment, which confirmed that deployment caused no detectable collateral damage to surrounding tissue. In vivo animal studies on the use of the shape memory alloy fixator for suturing tissue are ongoing to establish safety and healing effects.

  8. An automated interrupted suturing device for coronary artery bypass grafting: automated coronary anastomosis.

    Science.gov (United States)

    Shennib, H; Korkola, S J; Bousette, N; Giaid, A

    2000-09-01

    The purpose of this study was to have a preliminary assessment of the safety and efficacy of an automated vascular suturing device. The device (Heartflo, Perclose/Abbott Labs, Redwood City, CA), which delivers 10 interrupted 7-0 polypropylene sutures between side-to-side arteriotomies, was evaluated in animals (8 Yorkshire pigs). Tissue edge capture and quality of anastomosis were highly rated. Time of anastomoses averaged 22 minutes. This time was prolonged primarily due to suture management, tying of interrupted sutures, and learning curve effects. Six of the anastomoses were hemostatic and two required an additional stitch each. Angiography and histology of the anastomosis confirmed patency and quality of the anastomosis. Our preliminary results indicate that the Heartflo automated anastomotic device is safe and effective. Preclinical and clinical studies to validate its acute and long-term effectiveness will commence shortly.

  9. Safety and efficacy of unidirectional barbed suture in mini-laparotomy myomectomy

    Directory of Open Access Journals (Sweden)

    Ming-Chao Huang

    2013-03-01

    Conclusion: The unidirectional knotless barbed suture may facilitate the repair of uterine defects during mini-laparotomy myomectomy by significantly lowering operative time. It may also reduce the intraoperative blood loss.

  10. Evaluation of Polybutylate-Coated Braided Polyester (Ethibond) Sutures for Levator-Advancement Blepharoptosis Repair

    Science.gov (United States)

    Yulish, Michael; Pikkel, Joseph

    2012-01-01

    Purpose. To evaluate the efficacy and safety of polybutylate-coated braided polyester (Ethibond* 5-0) suture for levator aponeurosis suturing to the anterior tarsal surface in involutional blepharoptosis repair surgery. Methods. Ten consecutive patients (16 eyes) with acquired blepharoptosis which resulted from levator aponeurosis dehiscence with good levator function had gone through surgery and were followed up for, at least, one year. Results. There was no significant change between postoperative MRD1 measurements. No serious complications, such as infection of the sutures, inflammation, granuloma formation or ptosis recurrence, were registered. Conclusion. Polybutylate-coated braided polyester (Ethibond* 5-0) suture is a safe and effective material for involutional blepharoptosis repair surgery. PMID:24558592

  11. Evaluation of endoscopic laser excision of polypropylene mesh/sutures following anti-incontinence procedures.

    LENUS (Irish Health Repository)

    Davis, N F

    2012-11-01

    We reviewed our experience with and outcome of the largest series to our knowledge of patients who underwent endoscopic laser excision of eroded polypropylene mesh or sutures as a complication of previous anti-incontinence procedures.

  12. Successful term delivery after Khairy’s modified B-lynch suture technique: First case rep

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abbas

    2017-03-01

    Full Text Available Postpartum hemorrhage (PPH is a life-threatening obstetric complication. Uterine atony is the most common cause presenting in approximately 80% of cases. As regards management options, B-lynch brace suture, and its modifications have been used for more than a decade with a great success as a substitution for hysterectomy. Their efficiency in preserving future fertility is not well-established. This case reports the first successful pregnancy and delivery after one of the recent B-lynch suture modifications “Khairy’s modification” for control of atonic PPH during cesarean delivery. The patient got pregnant two months after the surgery. The course of pregnancy was smooth and she was delivered by Repeat cesarean section with no deformities of uterine cavity or contour. Khairy’s modified B-lynch suture is an effective technique that has no reported complications of the classic B-lynch suture or affection of subsequent fertility.

  13. Posterior Surgical Approach to Tuberculous Spondylitis | Shehu ...

    African Journals Online (AJOL)

    Objectives: Foraminotomy is a simple posterior surgical approach useful for treatment of radicular (nerve root) pain in TB spondylitis. It doesn't affect the stability of the facet joint, requires neither fusion nor implants. It is therefore cheap and affordable for patients with low income. We describe a simple form of posterior spinal ...

  14. Cervical disc hernia operations through posterior laminoforaminotomy

    OpenAIRE

    Yolas, Coskun; Ozdemir, Nuriye Guzin; Okay, Hilmi Onder; Kanat, Ayhan; Senol, Mehmet; Atci, Ibrahim Burak; Yilmaz, Hakan; Coban, Mustafa Kemal; Yuksel, Mehmet Onur; Kahraman, Umit

    2016-01-01

    Objective: The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. Materials and Methods: We retrospectively evaluated 35 patients ...

  15. Oxymetazoline in the treatment of posterior epistaxis.

    Science.gov (United States)

    Doo, G; Johnson, D S

    1999-08-01

    In this retrospective study, 36 patients were given oxymetazoline as a first step in treatment for posterior epistaxis. In 75% of the cases, epistaxis was effectively treated with oxymetazoline with no recurrent bleeding. All cases with recurrence resolved with continued administration of oxymetazoline. The results of this study propose a pharmacologic intervention for the treatment of posterior epistaxis.

  16. Posterior atlantooccipital subluxation in Down syndrome.

    Science.gov (United States)

    El-Khoury, G Y; Clark, C R; Dietz, F R; Harre, R G; Tozzi, J E; Kathol, M H

    1986-05-01

    Three Down syndrome patients with posterior atlantooccipital (AO) subluxation are described. All are asymptomatic. The subluxation becomes manifest during active extension of the neck and reduces in flexion. Methods of assessing posterior AO subluxation are discussed. The abnormality is attributed to ligamentous laxity in patients with Down syndrome.

  17. Stretch force guides finger-like pattern of bone formation in suture.

    Science.gov (United States)

    Wu, Bo-Hai; Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng

    2017-01-01

    Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction

  18. Posterior atlantooccipital membrane for duraplasty. Technical note.

    Science.gov (United States)

    Tubbs, R Shane; Wellons, John C; Blount, Jeffrey P; Oakes, W Jerry

    2002-09-01

    The authors describe the use of autogenetic posterior atlantooccipital (PAO) membrane for duraplasty following after posterior cranial fossa surgery. The PAO membrane is routinely exposed for procedures of the posterior cranial fossa and merely needs to be dissected free of the underlying dura mater. Recently this membrane was obtained in several pediatric patients following procedures of the posterior cranial fossa such as duraplasty in case of Chiari I malformation. No postoperative complications were found at 6-month follow-up examination. The advantages of this intervention include less manipulation of muscle and fascia than that involved in other procedures and, therefore, seemingly less postoperative pain and the negation of issues inherent with foreign-body graft sources. The authors believe this structure to be of use as a dural substitute in small dural openings of the posterior cranial fossa.

  19. A single centre comparative study of laparoscopic mesh rectopexy versus suture rectopexy

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Aim: The aim of our study is to compare the results of laparoscopic mesh vs. suture rectopexy. Materials and Methods: In this retrospective study, 70 patients including both male and female of age ranging between 20 years and 65 years (mean 42.5 yrs were subjected to laparoscopic rectopexy during the period between March 2007 and June 2012, of which 38 patients underwent laparoscopic mesh rectopexy and 32 patients laparoscopic suture rectopexy. These patients were followed up for a mean period of 12 months assessing first bowel movement, hospital stay, duration of surgery, faecal incontinence, constipation, recurrence and morbidity. Results: Duration of surgery was 100.8 ± 12.4 minutes in laparoscopic suture rectopexy and 120 ± 10.8 min in laparoscopic mesh rectopexy. Postoperatively, the mean time for the first bowel movement was 38 hrs and 40 hrs, respectively, for suture and mesh rectopexy. Mean hospital stay was five (range: 4-7 days. There was no significant postoperative complication except for one port site infection in mesh rectopexy group. Patients who had varying degree of incontinence preoperatively showed improvement after surgery. Eleven out of 18 (61.1% patients who underwent laparoscopic suture rectopexy as compared to nine of 19 (47.3% patients who underwent laparoscopic mesh rectopexy improved as regards constipation after surgery. Conclusion: There were no significant difference in both groups who underwent surgery except for patients undergoing suture rectopexy had better symptomatic improvement of continence and constipation. Also, cost of mesh used in laparoscopic mesh rectopexy is absent in lap suture rectopexy group. To conclude that laparoscopic suture rectopexy is a safe and feasible procedure and have comparable results as regards operative time, morbidity, bowel function, cost and recurrence or even slightly better results than mesh rectopexy.

  20. Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    Desire Abellán

    2016-04-01

    Full Text Available The aim of this study was to evaluate and compare the mechanical properties of five suture materials on three knot configurations when subjected to different physical conditions. Five 5-0 (silk, polyamide 6/66, polyglycolic acid, glycolide-e-caprolactone copolymer, polytetrafluoroethylene suture materials were used. Ten samples per group of each material were used. Three knot configurations were compared A.2=1=1 (forward–forward–reverse, B.2=1=1 (forward–reverse–forward, C.1=2=1 (forward–forward–reverse. Mechanical properties (failure load, elongation, knot slippage/breakage were measured using a universal testing machine. Samples were immersed in three different pH concentrations (4,7,9 at room temperature for 7 and 14 days. For the thermal cycle process, sutures were immersed in two water tanks at different temperatures (5 and 55 °C. Elongation and failure load were directly dependent on the suture material. Polyglycolic acid followed by glycolide-e-caprolactone copolymer showed the most knot failure load, while polytetrafluoroethylene showed the lowest (P < 0.001. Physical conditions had no effect on knot failure load (P = 0.494. Statistically significant differences were observed between knot configurations (P = 0.008. Additionally, individual assessment of suture material showed statistically significant results for combinations of particular knot configurations. Physical conditions, such as pH concentration and thermal cycle process, have no influence on suture mechanical properties. However, knot failure load depends on the suture material and knot configuration used. Consequently, specific suturing protocols might be recommended to obtain higher results of knot security.

  1. Assessment of the role of sutures in a lizard skull: a computer modelling study

    OpenAIRE

    Moazen, Mehran; Curtis, Neil; O'Higgins, Paul; Jones, Marc E.H; Evans, Susan E; Fagan, Michael J

    2008-01-01

    Sutures form an integral part of the functioning skull, but their role has long been debated among vertebrate morphologists and palaeontologists. Furthermore, the relationship between typical skull sutures, and those involved in cranial kinesis, is poorly understood. In a series of computational modelling studies, complex loading conditions obtained through multibody dynamics analysis were imposed on a finite element model of the skull of Uromastyx hardwickii, an akinetic herbivorous lizard. ...

  2. [Mechanical suture during resection of the rectum through the abdomen (author's transl)].

    Science.gov (United States)

    Gauthier-Benoît, C; Prat, A

    1979-01-01

    A mechanical suture using the URSS PKZ 28 or SPTU stapler was used in 30 low colo-rectal anastomoses. There were two deaths related to anastomotic complications. It is safe to establish a colostomy when the colon is not well prepared. Fistulae are frequent after palliative operations: this is a poor indication. Local recurrences are no more frequent with stapling than with manual suture.

  3. Single Incision Distal Biceps Repair With Hemi-Krackow Suture Technique: Surgical Technique and Early Outcomes

    OpenAIRE

    Goljan, Peter; Patel, Nimit; Stull, Justin D.; Donnelly, Brandon P.; Culp, Randall W.

    2016-01-01

    Background: Many surgical methods exist for distal biceps repair. We present the technique and early outcomes of a series of distal biceps repairs completed with a novel suturing technique utilizing a hemi-Krackow locking stitch at the tendon-bone interface. Methods: A retrospective review was performed of patients who underwent primary distal biceps repair using a single anterior incision with 2 suture anchors utilizing a hemi-Krackow stitch. With both anchors, a locking stitch along the ten...

  4. Clinical inquiries. How does tissue adhesive compare with suturing for superficial lacerations?

    Science.gov (United States)

    Aukerman, Douglas F; Sebastianelli, Wayne J; Nashelsky, Joan

    2005-04-01

    Tissue adhesives are effective and yield results comparable to those with conventional suturing of superficial, linear, and low-tension lacerations. The cosmetic outcome is similar; wound complications, such as infection and dehiscence, may be lower with tissue adhesives. Wound closure of superficial lacerations by tissue adhesives is quicker and less painful compared with conventional suturing (strength of recommendation: A, systematic reviews of randomized trials).

  5. Limits to Drift Chamber Resolution

    CERN Document Server

    Riegler, Werner

    1998-01-01

    ATLAS (A Large Toroidal LHC Apparatus) will be a general-purpose experiment at the Large Hadron Collider that will be operational at CERN in the year 2004. The ATLAS muon spectrometer aims for a momentum resolution of 10% for a transverse momentum of pT=1TeV. The precision tracking devices in the muon system will be high pressure drift tubes (MDTs) with a single wire resolution of 1100 chambers covering an area of ≈ 2500m2. The high counting rates in the spectrometer as well as the aim for excellent spatial resolution and high efficiency put severe constraints on the MDT operating parameters. This work describes a detailed study of all the resolution limiting factors in the ATLAS environment. A ’full chain’ simulation of the MDT response to photons and charged particles as well as quantitative comparisons with measurements was performed. The good agreement between simulation and measurements resulted in a profound understanding of the drift chamber processes and the individual contributions to the spat...

  6. Neutron Detection with Bubble Chambers

    Science.gov (United States)

    Ghilea, M. C.; Lerche, R. A.; Disdier, L.

    2005-10-01

    To improve neutron imaging resolution, we have developed a general imaging design tool for inertial confinement fusion facilities that can simulate aperture errors, generate arbitrary neutron source distributions, simulate arbitrary aperture shapes, calculate point-spread functions using ray tracing, and reconstruct source images using a variety of filter functions. Predicted system performance can be compared to various concepts before construction. This software design tool is being developed for the UR/LLE OMEGA laser and the NIF as part of a process to design and build an imaging system based on a bubble chamber detectorootnotetextR. A. Lerche et al., Rev. Sci. Instrum. 74, 1709 (2003). for the UR/LLE OMEGA laser. This talk will present the latest results on aperture contributions to system performance and review the conceptual design of the bubble chamber-based imaging system, its conceptual design being reviewed in the second part of the presentation. This work was supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC52-92SF19460.

  7. Physicist makes muon chamber sing

    CERN Multimedia

    2007-01-01

    This Monitored Drift Tube detector, consisting of argon-CO2-filled aluminium tubes with a wire down the centre of each, will track muons in ATLAS; Tiecke used a single tube from one of these detectors to create the pipes in his organ. Particle physicists can make good musicians; but did you know particle detectors can make good music? That's what NIKHEF physicist Henk Tiecke learned when he used pipes cut from the ATLAS Monitored Drift Tube detector (MDT) to build his own working Dutch-style barrel organ in the autumn of 2005. 'I like to work with my hands,' said Tiecke, who worked as a senior physicist at NIKHEF, Amsterdam, on ZEUS until his retirement last summer. Tiecke had already constructed his barrel organ when he visited some colleagues in the ATLAS muon chambers production area at Nikhef in 2005. He noticed that the aluminium tubes they were using to build the chambers were about three centimetres in diameter-just the right size for a pipe in a barrel organ. 'The sound is not as nice as from wooden...

  8. Morphology of cranial sutures and radiologic evaluation of the variations of intersutural bones.

    Science.gov (United States)

    Çalışkan, Selma; Oğuz, Kader Karlı; Tunalı, Selçuk; Aldur, Muhammed Mustafa; Erçakmak, Burcu; Sargon, Mustafa Fevzi

    2018-03-23

    As far as our literature searches showed us, morphological characteristics of cranium such as sutures, sutural bones and fontanelles had been examined from the skulls in the museums and dry specimens until now. As a modern method, 3D virtual remodeling of cranial bones by using MDCT-CTA can display in vivo morphological characteristics. In our study, we aimed to determine the presence and incidence of these morphological characteristics that can be clinically significant in our population, by using radiologic methods. We examined head and neck regions of 185 patients via MDCT-CTA. We evaluated radiologically detectable variations of the metopic sutures, lambda, bregma, asterion and pterion, which can be very easily confused with fractures. Additionally, the differences between the genders and incidence of coexistence of these variations were evaluated. According to our study, the incidence of persistent metopic suture was 8.1% and the incidence of lambda variations was 5.9%. Variations were most commonly encountered on the left asterion, and least commonly on the bregma and left pterion. In the evaluation of the coexistence of the parameters and combinations; the wormian bones located at the right and left asterions were detected. There were no statistically significant differences between genders. Variations of the sutures and sutural bones can be easily misdiagnosed with the fractures of related bony regions in unconscious patients with multiple traumas. During surgical interventions in these type of patients; surgeons must take this fact into consideration in order to make differential diagnosis of fractures and intersutural bone variations.

  9. Closure of round cutaneous defects progressively with the purse string suture technique.

    Science.gov (United States)

    Küçükdurmaz, Fatih; Agir, Ismail; Gümüstas, Seyitali; Kivilcim, Hakan; Tetik, Cihangir

    2015-01-01

    There are many closure techniques available to cutaneous surgeons. One of them is the purse-string suture which is used to provide complete or partial closure of round skin defects. In our animal study; we closed skin defects with using subcuticular purse string suture technique by progressively cinching wound and we aim to more rapidly healing according to secondary healing. After anaesthetize, we created a 4 cm diameter circular full thickness skin defect on dorsal area of rats. In group 1, subcuticular purse string suture was applied by using a nonabsorbable and monofilament suture and a sliding arthroscopic knot was applied to both ends. Arthroscopic suture was shift 1 cm forward every day. In group 2 skin defect was leaved open and daily dressing was made and in both group defect diameters were measured every day and noted. The skin defects were closed totally after 15 days in group 1 but in group 2 defects were reduced but still had a mean 1,5-cm diameter sircular defect. Closing large circular wound with purse string suture and gradual tightening decreases the healing time and expand the skin tissue without using any tissue expander.

  10. Instructional PowerPoint presentations for cutaneous wound healing and tissue response to sutures.

    Science.gov (United States)

    Stroncek, John D; Bell, Nicole; Reichert, W Monty

    2009-09-15

    Wound healing is an intricate process involving the interaction of cells and molecules, resulting in a complex series of events that change the morphology and characteristics of the wounded area. Interactive animations are useful for illustrating challenging concepts, helping students learn and retain new material. Instructional PowerPoint presentations describing the basic elements of cutaneous wound healing and the response of cutaneous tissue to sutures were developed by seven biomedical engineering students at Duke University. "Cutaneous Wound Healing.ppt" is an interactive presentation reviewing the four phases of wound healing (hemostasis, inflammation, repair, and remodeling) as well as the major molecular and cellular mechanisms that comprise these processes for cutaneous tissue. "Tissue Response to Sutures.ppt" is an interactive presentation that uses sutures to illustrate the foreign body response to biomaterials in cutaneous tissue. The tissue response program reviews the basics of suturing, common suture materials, and the tissue, cellular, and molecular responses to absorbable and nonabsorbable sutures. This manuscript provides a brief overview of the programs that are freely available on the Duke Center for Biomolecular and Tissue Engineering web site at http://bte.egr.duke.edu. Copyright 2008 Wiley Periodicals, Inc.

  11. Augmentation of tendon healing with butyric acid-impregnated sutures: biomechanical evaluation in a rabbit model.

    Science.gov (United States)

    Leek, Bryan T; Tasto, James P; Tibor, Lisa M; Healey, Robert M; Freemont, Anthony; Linn, Michael S; Chase, Derek E; Amiel, David

    2012-08-01

    Butyric acid (BA) has been shown to be angiogenic and to enhance transcriptional activity in tissue. These properties of BA have the potential to augment biological healing of a repaired tendon. To evaluate this possibility both biomechanically and histologically in an animal tendon repair model. Controlled laboratory study. A rabbit Achilles tendon healing model was used to evaluate the biomechanical strength and histological properties at 6 and 12 weeks after repair. Unilateral tendon defects were created in the middle bundle of the Achilles tendon of each rabbit, which were repaired equivalently with either Ultrabraid BA-impregnated sutures or control Ultrabraid sutures. After 6 weeks, BA-impregnated suture repairs had a significantly increased (P Tendons repaired with BA-impregnated sutures demonstrated improved biomechanical properties at 6 weeks relative to control sutures, suggesting a neoangiogenic mechanism of enhanced healing through an increased myofibroblast presence. These findings demonstrate that a relatively simple alteration of suture material may augment early tendon healing to create a stronger repair construct during this time.

  12. Tarsal platform show after upper eyelid blepharoplasty with or without brassiere sutures

    Directory of Open Access Journals (Sweden)

    Marisa Novaes de Figueiredo

    Full Text Available ABSTRACT Purpose: Increased tarsal platform show (TPS and decreased brow fat span (BFS are associated with favorable results in women undergoing cosmetic blepharoplasty. We conducted a study to evaluate the efficacy of upper blepharoplasty with or without a technique (brassiere sutures to increase TPS and decrease BFS. Methods: This is a prospective, randomized, comparative, case series study of 100 eyelids (50 consecutive women patients treated with cosmetic upper blepharoplasty performed by a single surgeon. Patients were randomized to receive traditional upper blepharoplasty with a single running suture skin closure versus orbicularis oculi muscle fixation to the periosteum (brassiere sutures prior to skin closure. Data on patient age, duration of follow-up, complications, and treatment were analyzed. The mean TPS, mean BFS, and mean TPS/BFS ratio were measured at three anatomic landmarks before and after surgery. Results: Fifty-six eyelids (28 patients were treated with traditional single suture blepharoplasty, and 44 eyelids (22 patients had brassiere sutures. In both groups, paired t-tests indicate significant differences between preoperative and postoperative evaluations (p0.05. Conclusions: Brassiere sutures during upper blepharoplasty and traditional blepharoplasty were associated with postoperative increase in TPS, decrease in BFS, and increase in TPS/BFS, without statistically significant differences between these surgeries.

  13. Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.

    Science.gov (United States)

    Geiger, Madeleine; Haussman, Sinah

    2016-04-01

    Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. © 2016 Wiley Periodicals, Inc.

  14. Bile duct stone formation around a nylon suture after gastrectomy: a case report.

    Science.gov (United States)

    Maeda, Chiyo; Yokoyama, Naoyuki; Otani, Tetsuya; Katada, Tomohiro; Sudo, Natsuru; Ikeno, Yoshinobu; Matsuura, Fumiaki; Iwaya, Akira; Yamazaki, Toshiyuki; Kuwabara, Shirou; Katayanagi, Norio

    2013-03-22

    Many cases of choledocholiths formed around sutures and clips used during cholecystectomy have been reported. We describe a case of gallstone formation around a nylon suture after non-biliary surgery. To the best of our knowledge, this is the first report of such a case. A 75-year-old Japanese man, who had undergone distal gastrectomy for gastric cancer and reconstruction with the Billroth II method 8 years earlier, presented with gastric discomfort. Abdominal ultrasonography was conducted and we diagnosed cholecysto-choledocholithiasis with dilatation of the intrahepatic bile duct. He underwent cholecystectomy and cholangioduodenostomy for choledocholith removal. Gallstones, which had formed around a nylon suture used during the previous gastrectomy, were found in the bile duct. Sutures of the same material had also been placed on the duodenum. Chemical analysis revealed that the stones were composed of calcium bilirubinate. The patient was discharged on postoperative day 19, and choledocholithiasis has not recurred thus far. The findings from this case suggest that standard, non-resorbable sutures used in gastrectomy may be associated with the formation of bile duct stones; therefore, absorbable suture material may be required to avert gallstone formation even in the case of gastrectomy.

  15. A clinical study on the influence of suturing material on oral wound healing

    Directory of Open Access Journals (Sweden)

    Gazivoda Dragan

    2015-01-01

    Full Text Available Background/Aim. Suture materials play an important role in healing, enabling reconstruction and reassembly of tissue separated by the surgical procedure or trauma, and at the same time facilitating and promoting healing and hemostasis. Suture materials are used daily in oral surgery, and are considered to be substances most commonly implanted in human body. The aim of this clinical study was to examine the speed of wound healing and complications incidence, after the use of three different absorbable synthetic suture materials in oral surgery (catgut, Dexon and Vicryl rapide, and to ascertain which one is the most suitable for oral surgery. Methods. The study was conducted on 96 patients undergoing root resection or surgical extraction of third molars. Each of the suture materials (catgut, Dexon and Vicryl rapide was used for 8 root resections and 8 surgical third molar extractions in the maxilla, as well as in the mandible (a total of 32 surgical interventions for each suture material. Results. The faster wound healing was obtained with Vicryl rapide compared to other two suturing material tested. There was no significant difference regarding the presence of local reaction in all the three groups of patients on the 21st postoperative day. Conclusion. The results of our clinical study point out that Vycrilrapid contributes more than catgut or Dexon to faster healing of human wounds, with fewer incidences of wound dehiscence and milder local reactions.

  16. Investigation of the best suture pattern to close a stuffed Christmas turkey.

    Science.gov (United States)

    Verwilghen, D; Busoni, V; van Galen, G; Wilke, M

    Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.

  17. Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing

    Science.gov (United States)

    Malik, I. A.; Mirkhalaf, M.; Barthelat, F.

    2017-05-01

    Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.

  18. Sutura palatina mediana: avaliação do grau de ossificação em crânios humanos Mid-palatal suture: evaluation of the ossification degree in human skulls

    Directory of Open Access Journals (Sweden)

    Jussara Ennes

    2004-10-01

    Full Text Available OBJETIVOS: Avaliar o grau de ossificação da sutura palatina mediana em crânios humanos de diferentes grupos etários. AMOSTRA: Crânios humanos (28 divididos em quatro grupos de acordo com a fase do desenvolvimento cronológico: crianças, adultos jovens, adultos e idosos. MATERIAL: Radiografias Oclusais Totais da Maxila dos crânios dos diferentes grupos (28. Imagens digitalizadas das Radiografias Oclusais Totais da Maxila (28. MÉTODOS: A presença de pontes de ossificação na sutura palatina mediana foi identificada macroscópica e estereomicroscopicamente, registrada e quantificada. Os crânios foram radiografados pela Técnica Oclusal total da Maxila, com modificação na posição do filme, no eixo horizontal. As imagens radiográficas obtidas foram digitalizadas e submetidas à variação de tons claros e escuros e ao ajuste de contraste e brilho para a investigação do grau de ossificação da sutura palatina mediana. CONCLUSÃO: Concluiu-se que a ossificação da sutura palatina mediana inicia-se principalmente na fase adulta e no segmento posterior. A técnica Radiográfica Oclusal Total da Maxila não proporciona imagem adequada à identificação do grau de ossificação na sutura palatina mediana.OBJECTIVES: To analyze the mid-palatal suture ossification rate on human skulls. SAMPLE: Human skulls (28 divided among four groups according to chronological developmental phases: child, teen-ager, adult and elderly. MATERIAL: Maxillary Total Occlusal radiographs from different groups of skulls (28. Digitalized images from Maxillary Total Occlusal radiographs (28. METHODS: The presence of ossification bridges on the mid-palatal suture were identified, registered and qualified. The radiographs of the skulls were taken using the Maxillary Total Occlusal technique, modifying the horizontal position of the film. These radiograph images were digitalized and submitted to brightness and contrast adjustments to investigate mid-palatal suture

  19. Fusion Patterns in the Skulls of Modern Archosaurs Reveal That Sutures Are Ambiguous Maturity Indicators for the Dinosauria.

    Directory of Open Access Journals (Sweden)

    Alida M Bailleul

    Full Text Available The sutures of the skulls of vertebrates are generally open early in life and slowly close as maturity is attained. The assumption that all vertebrates follow this pattern of progressive sutural closure has been used to assess maturity in the fossil remains of non-avian dinosaurs. Here, we test this assumption in two members of the Extant Phylogenetic Bracket of the Dinosauria, the emu, Dromaius novaehollandiae and the American alligator, Alligator mississippiensis, by investigating the sequence and timing of sutural fusion in their skulls. As expected, almost all the sutures in the emu skull progressively close (i.e., they get narrower and then obliterate during ontogeny. However, in the American alligator, only two sutures out of 36 obliterate completely and they do so during embryonic development. Surprisingly, as maturity progresses, many sutures of alligators become wider in large individuals compared to younger, smaller individuals. Histological and histomorphometric analyses on two sutures and one synchondrosis in an ontogenetic series of American alligator confirmed our morphological observations. This pattern of sutural widening might reflect feeding biomechanics and dietary changes through ontogeny. Our findings show that progressive sutural closure is not always observed in extant archosaurs, and therefore suggest that cranial sutural fusion is an ambiguous proxy for assessing maturity in non-avian dinosaurs.

  20. Swimming mechanics and propulsive efficiency in the chambered nautilus

    Science.gov (United States)

    Neil, Thomas R.

    2018-01-01

    The chambered nautilus (Nautilus pompilius) encounters severe environmental hypoxia during diurnal vertical movements in the ocean. The metabolic cost of locomotion (Cmet) and swimming performance depend on how efficiently momentum is imparted to the water and how long on-board oxygen stores last. While propulsive efficiency is generally thought to be relatively low in jet propelled animals, the low Cmet in Nautilus indicates that this is not the case. We measured the wake structure in Nautilus during jet propulsion swimming, to determine their propulsive efficiency. Animals swam with either an anterior-first or posterior-first orientation. With increasing swimming speed, whole cycle propulsive efficiency increased during posterior-first swimming but decreased during anterior-first swimming, reaching a maximum of 0.76. The highest propulsive efficiencies were achieved by using an asymmetrical contractile cycle in which the fluid ejection phase was relatively longer than the refilling phase, reducing the volume flow rate of the ejected fluid. Our results demonstrate that a relatively high whole cycle propulsive efficiency underlies the low Cmet in Nautilus, representing a strategy to reduce the metabolic demands in an animal that spends a significant part of its daily life in a hypoxic environment. PMID:29515819