  1. Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

    Science.gov (United States)

    Parekh, Parag; Green, W Richard; Stark, Walter J; Akpek, Esen Karamursel

    2007-02-01

    To report the occurrence of subluxation of suture-fixated posterior chamber (PC) intraocular lenses (IOL) and elucidate the mechanisms involved. Prospective clinicopathologic study. A single 10-0 Prolene suture explanted from a patient who experienced subluxation of his PC-IOL, 11.5 years after placement. Furthermore, multiple 10-0 Prolene sutures and PC-IOLs used for iris fixation were studied as controls. Scanning electron microscopy (SEM) was used to analyze the surface of the explanted suture. In addition, randomly selected 10-0 Prolene sutures cut with Vannas scissors and cut with the positioning holes of a randomly selected PC-IOL identical to that implanted in the patient's eye were examined as controls. Finally, the positioning holes of several randomly selected, iris-fixated PC-IOLs were studied using SEM with particular attention to surface quality and edge finish. Presence of any signs of suture degradation, the character of the cut edge of the suture, as well as the characteristics of the positioning holes of the PC-IOLs. Scanning electron microscopy of the explanted suture revealed sharply cut edges, without significant degradation of the suture, and no intact loop. Scanning electron microscopy of the control suture cut with a PC-IOL demonstrated a similarly cut edge. The positioning holes of the examined PC-IOLs had a sharp edge, and some also had an imperfect finish. We conclude that the surface properties of the positioning holes lead to cutting of the suture, and subsequent subluxation of the PC-IOL.

  2. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  3. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    Directory of Open Access Journals (Sweden)

    Ertugrul Can

    2016-01-01

    Full Text Available Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL. Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes.

  4. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  5. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman’s Knot

    Directory of Open Access Journals (Sweden)

    Yong Un Shin

    2017-01-01

    Full Text Available Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL using a single fisherman’s knot (SFK. Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  6. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot.

    Science.gov (United States)

    Shin, Yong Un; Seong, Mincheol; Cho, Hee Yoon; Kang, Min Ho

    2017-01-01

    To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  7. [Endoscopically controlled optimization of trans-scleral suture fixation of posterior chamber lenses in the ciliary sulcus].

    Science.gov (United States)

    Althaus, C; Sundmacher, R

    1993-08-01

    Two technical difficulties have to be overcome in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration through the sulcus, and second, exact positioning of the PCL haptics in the sulcus. Incongruence of the two may lead to long-term complications by compression or even strangulation of ciliary processes. Intraocular endoscopy was used intraoperatively to visualize the site of needle penetration and the final location of the haptics in patients. It turned out that with our previously described standard techniques the precision was far less than anticipated. Thus, new technical ways had to be sought to improve the precision of positioning. In secondary implantation without perforating keratoplasty we achieved the best results when the needle was passed ab externo before opening the eye and before anterior vitrectomy, taking advantage of a precisely prepared sclerocorneal zone. Passing the needle ab externo in an already hypotonic eyeball gives much less precise results. In combination with perforating keratoplasty with an open-sky approach, needle penetration ab interno is reliable. Correct positioning of the PCL haptics is at least as difficult as correct needle penetration, a fact which up to now has mostly been ignored. In 33 consecutively operated eyes the technique of implantation and PCL design was varied under endoscopical control.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries

    Directory of Open Access Journals (Sweden)

    Xiangjia Zhu

    2017-01-01

    Full Text Available Purpose. To evaluate the tilt, decentration, and internal higher-order aberrations (HOAs of sutured posterior-chamber intraocular lenses (IOLs in patients with open globe injuries. Methods. 46 consecutive patients (47 eyes who underwent transsclerally sutured IOL implantation were enrolled in this prospective cohort study. Nineteen eyes had a history of open globe injury. The tilt and decentration of the IOLs and the visual quality were measured 1 month after surgery. Results. The horizontal tilt and decentration of the IOLs in the open-globe-injury group were significantly higher than those in the control group (both P<0.05. In the open-globe-injury group, the horizontal decentration was significantly greater in the limbus-sclera-involved group (n=11 than in the only-cornea-involved group (n=8, P=0.040. The internal coma, 3rd-order, and total HOA values at pupil sizes of 4 mm (P=0.006 and 6 mm (P=0.013 were significantly higher in the open-globe-injury group than in the controls. Consequently, the optical quality data for the modulation transfer function and the Strehl ratio (all P<0.05 were significantly poorer in the open-globe-injury group. Conclusions. Open globe injuries damage the structural integrity of the eyeball, resulting in more-misaligned sutured IOLs and poorer visual quality.

  9. Craniosynostosis of coronal suture in Twist1+/- mice occurs through endochondral ossification recapitulating the physiological closure of posterior frontal suture

    Directory of Open Access Journals (Sweden)

    Bjorn eBehr

    2011-07-01

    Full Text Available Craniosynostosis, the premature closure of cranial suture, is a pathologic condition that affects 1/2000 live births. Saethre-Chotzen syndrome is a genetic condition characterized by craniosynostosis. The Saethre-Chotzen syndrome, which is defined by loss-of-function mutations in the TWIST gene, is the second most prevalent craniosynostosis. Although much of the genetics and phenotypes in craniosynostosis syndromes is understood, less is known about the underlying ossification mechanism during suture closure. We have previously demonstrated that physiological closure of the posterior frontal (PF suture occurs through endochondral ossification. Moreover, we revealed that antagonizing canonical Wnt signaling in the sagittal suture leads to endochondral ossification of the suture mesenchyme and sagittal synostosis, presumably by inhibiting Twist1. Classic Saethre-Chotzen syndrome is characterized by coronal synostosis, and the haploinsufficient Twist1+/- mice represents a suitable model for studying this syndrome. Thus, we seeked to understand the underlying ossification process in coronal craniosynostosis in Twist1+/- mice. Our data indicate that coronal suture closure in Twist1+/- mice occurs between postnatal day 9 to 13 by endochondral ossification, as shown by histology, gene expression analysis and immunohistochemistry. In conclusion, this study reveals that coronal craniosynostosis in Twist1+/- mice occurs through endochondral ossification. Moreover, it suggests that haploinsufficency of Twist1 gene, a target of canonical Wnt-signaling, and inhibitor of chondrogenesis, mimics conditions of inactive canonical Wnt-signaling leading to craniosynostosis.

  10. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Scharioth, Gabor B; Prasad, Som; Georgalas, Ilias; Tataru, Calin; Pavlidis, Mitrofanis

    2010-02-01

    To report the intermediate multicenter results of a technique of sutureless intrascleral fixation of a standard 3-piece posterior chamber intraocular lens (PC IOL) in the ciliary sulcus. Four European ophthalmology centers. A technique for sutureless intrascleral fixation of the haptics of a standard 3-piece PC IOL was retrospectively evaluated. The technique uses standardized maneuvers to fixate the PC IOL without need for special haptic architecture or preparation or haptic suturing. All patients having IOL implantation by the technique were evaluated for preoperative status (visual acuity, refractive error, preexisting ocular conditions, optical biometry), postoperative status, complications, and need for further surgery. The study evaluated 63 consecutive patients from 4 institutions (4 surgeons). The median follow-up was 7 months. Two dislocated PC IOLs (3.6%) were decentered; the other 61 IOLs (96.8%) were stable and well centered. There were no cases of recurrent dislocation, endophthalmitis, retinal detachment, or glaucoma. Fixation of PC IOL haptics in a limbus-parallel scleral tunnel provided exact centration and axial stability of the IOL and prevented distortion and subluxation in most cases. Copyright 2010 ASCRS and ESCRS. All rights reserved.

  11. The efficiacy of anterior and posterior archs suturation at inferior tonsillar pole for posttonsillectomy pain control.

    Science.gov (United States)

    Sakallioğlu, Oner; Düzer, Sertaç; Kapusuz, Zeliha

    2014-01-01

    The aim of our study was to investigate the efficiacy of the suturation technique after completing the tonsillectomy procedure for posttonsillectomy pain control in adult patients. August 2010-February 2011, 44 adult patients, ages ranged from 16 to 41 years old who underwent tonsillectomy at Elaziğ Training and Research Hospital Otorhinolaryngology Clinic were included to the study. After tonsillectomy procedure, anterior and posterior tonsillar archs were sutured each other and so, the area of tonsillectomy lodges which covered with mucosa were increased. Twenty two patients who applied posttonsillectomy suturation were used as study group and remnant 22 patients who did not applied posttonsillectomy suturation were used as control group. The visual analogue score (VAS) was used to evaluate the postoperative pain degree (0 no pain, 10 worst pain). ANOVA test (two ways classification with repeated measures) was used for statistical analysis of VAS values. P < 0.05 was accepted as statistically significant. The effect of time (each post-operative day) on VAS values was significant. The mean VAS values between study and control group on post-operative day 1st, 3rd, 7th, and 10th were statistically significant (P < 0.05). The severity of posttonsillectomy pain was less in study group patients than control group patients. The suturation of anterior and posterior tonsillar archs after tonsillectomy procedure was found effective to alleviate the posttonsillectomy pain in adult patients.

  12. Evaluation of pars plana sclera fixation of posterior chamber intraocular lens

    Directory of Open Access Journals (Sweden)

    Fangju Han

    2014-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL implantation with transscleral fixation. Design and Setting: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People′s Hospital. Materials and Methods: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. Results: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05. No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. Conclusion: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support.

  13. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  14. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  15. Glued intrascleral fixation of posterior chamber intraocular lens in children.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Prakash, Dimple; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya

    2012-04-01

    To evaluate the short-term results of glued intrascleral fixation of posterior chamber intraocular lens (glued IOL) in children without adequate capsular support. Noncomparative retrospective observational case series. Institutional practice. Forty-one eyes of 33 children who underwent glued IOL implantation were retrospectively evaluated. The indications were postsurgical aphakia, subluxated cataract, ectopia lentis, traumatic subluxation, and decentered IOL. Visual acuity (VA), endothelial cell changes, intraoperative and postoperative complications. The mean age at the time of glued IOL was 10.7±3.6 years (range 5-15). The mean duration of follow-up after surgery was 17.5±8.5 months (range 12-36). The mean postoperative best spectacle-corrected visual acuity (BCVA in decimal equivalent) was 0.43±0.33 and there was significant change noted (P20/60 BCVA was obtained in 17.1% and 46.3% of eyes respectively. BCVA improvement more than 1 line was seen in 22 eyes (53.6%). The mean postoperative refraction was myopic (-1.19±0.7 diopters [D]) in 19 eyes and hyperopic (+1.02±0.7 D) in 22 eyes. The mean endothelial loss was 4.13% (range 1.3%-5.94%). The 3 causes of reduced BCVA were the preexisting corneal, retinal pathology, and amblyopia. Postoperative complications included optic capture in 1 eye (2.4%), macular edema in 2 eyes (4.8%), and clinical decentration in 2 eyes (4.8%). There was no postoperative retinal detachment, IOL dislocation, endophthalmitis, or glaucoma. Short-term results in children after glued IOL were favorable, with a low rate of complications. However, regular follow-ups are required since long-term risks are unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  17. Anterior capsular support for posterior chamber intraocular lenses following vitreous loss in endocapsular surgery

    Directory of Open Access Journals (Sweden)

    Jacob Pushpa

    1993-01-01

    Full Text Available We used anterior capsular support for posterior chamber intraocular lenses (PC IOLs in fourteen eyes with large posterior capsular ruptures. An endocapsular technique preserved the anterior capsule and facilitated implantation. With a median follow up of 8.5 months, all patients had a visual acuity of 6/9 or better. One lens was lost in the vitreous and one patient had a clinically significant cystoid macular edema. In the event of a posterior capsular rupture we suggest this technique as an alternative to anterior chamber or scleral-fixated lenses

  18. Repair of Unstable Posterior Sternoclavicular Dislocation Using Nonabsorbable Tape Suture and Tension Band Technique: A Case Report with Good Results

    Directory of Open Access Journals (Sweden)

    Ekrem Aydın

    2015-01-01

    Full Text Available Posterior sternoclavicular joint dislocation (PSCJD is quite a rare condition. Nearly half of the closed reduction attempts fail due to various reasons. In this paper, we present a 25-year-old male patient who was admitted to the emergency department in our hospital after having a motor-vehicle accident. It was decided to do PSCJD after physical and imaging studies. Following necessary preparations, closed reduction was attempted with abduction-traction maneuver under general anesthesia; however, adequate stabilization could not be achieved and redislocation was detected during control. Therefore, joint was stabilized with tension band technique using 6 mm polyamide nonabsorbable type suture during open reduction. Painless and complete range of motion in shoulder was achieved at the postoperative 10th week.

  19. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Comparação entre os resultados pós-operatórios de pacientes submetidos ao procedimento tríplice e transplante de córnea combinado a fixação secundária de lente intra-ocular Comparison between the postoperative results of triple procedure and combined penetrating keratoplasty/ transsclerally sutured posterior chamber lens implantation

    Directory of Open Access Journals (Sweden)

    Daniela Maggioni Pereira Leão

    2006-08-01

    Full Text Available OBJETIVO: Comparar os resultados pós-operatórios de 2 grupos de pacientes submetidos a transplante de córnea com técnicas e tempo cirúrgico diferentes, em relação à abordagem do cristalino e/ou lente intra-ocular. MÉTODOS: Neste estudo retrospectivo foram analisados 37 olhos de pacientes divididos em 2 grupos: extração de catarata, implante de lentes intra-oculares (LIO e transplante de córnea no mesmo tempo cirúrgico - grupo 1 (G1 e extração de catarata sem implante de lentes intra-oculares no primeiro tempo cirúrgico e fixação secundária de lentes intra-oculares associada a transplante de córnea no segundo tempo cirúrgico - grupo 2 (G2. As variáveis estudadas foram: acuidade visual, pressão intra-ocular (PIO, astigmatismo refracional, astigmatismo ceratométrico e complicações pós-operatórias. RESULTADOS: Foi observado melhora da acuidade visual nos 2 grupos (G1 pPURPOSE: To compare the outcomes of two surgical techniques of penetrating keratoplasty with different surgical time, regarding the crystalline and the intraocular lens. METHODS: This retrospective study included 37 patients' eyes divided into 2 groups: extracapsular cataract extraction, posterior chamber intraocular lens implantation and penetrating keratoplasty (Group 1, G1 and transscleral fixation of posterior chamber lens and penetrating keratoplasty (Group 2, G2. The following parameters were recorded: visual acuity, intraocular pressure, refractive astigmatism, complication and keratometric astigmatism. RESULTS: Visual acuity improved in the two groups (G1 p<0.001 and G2 p=0.008. In G2 a significant change for the worse of intraocular pressure outcome was observed when compared with the other group (p=0.014. Regarding refractive and keratometric astigmatism no significant differences between the groups were found. The follow-up was 11 months. CONCLUSION: The most important negative prognostic factor affecting visual acuity was the postkeratoplasty

  1. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  2. [Subluxation of scleral-fixated PC IOL caused by polypropylene suture degradation--case report].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Czarnowska, Elzbieta; Zajaczkowska, Agnieszka

    2009-01-01

    The purpose of the study is to evaluate factors related to late-onset of lens subluxation in transscleral sutured posterior chamber IOL. We report a child, which required surgical treatment for dislocation of a scleral-sutured PC IOL. 11 years earlier the secondary lens implantation with scleral fixation was performed in 4 years old boy. The first surgical procedure included an anterior victrectomy and suturing a single- piece PMMA IOL under the scleral flaps with a 10-0 polipropylene suture. The second--included explantation of the dislocated lens. Optic and scanning electron microscopy was used to analyze the surface of the explanted remnants of the breakage suture. Microscopic findings indicate that the late suture breakage and subluxation of suture-fixated PC IOL was due to the degradation of polypropylene suture.

  3. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  4. Suture supported P C IOL in a homocystinuric child.

    Directory of Open Access Journals (Sweden)

    Bhatti S

    1996-01-01

    Full Text Available A homocystinuric child presented with a secondary pupillary block glaucoma due to anteriorly subluxated lens. After removal of the subluxated lens, a suture supported posterior chamber IOL was implanted. Postoperative complication of cerebral venous thrombosis following general anaesthesia was managed with high doses of pyridoxine special diet and drugs.

  5. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  6. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  7. Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis

    Directory of Open Access Journals (Sweden)

    Huang J

    2015-02-01

    Full Text Available Jane Huang,1 Eiichi Uchio,1 Satoru Goto2 1Department of Ophthalmology, Fukuoka University School of Medicine, Fukuoka, 2Nihon ESI KK Technical Division, Tokyo, Japan Purpose: To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL.Materials and methods: Simulations in a model human eye were performed with a computer using a finite element analysis program created by Nihon, ESI Group. The airbag was set to be deployed at five different velocities and to impact on eyes with three different axial lengths. These eyes were set to have transsclerally fixated PC IOL by a 10-0 polypropylene possessing a tensile force limit of 0.16 N according to the United States Pharmacopeia XXII.Results: The corneoscleral opening was observed at a speed of 40 m/second or more in all model eyes. Eyes with the longest axial length of 25.85 mm had the greatest extent of deformity at any given impact velocity. The impact force exceeded the tensile force of 10-0 polypropylene at an impact velocity of 60 m/second in all eyes, causing breakage of the suture. Conclusion: Eyes with transsclerally fixated PC IOL could rupture from airbag impact at high velocities. Eyes with long axial lengths experienced a greater deformity upon airbag impact due to a thinner eye wall. Further basic research on the biomechanical response for assessing eye injuries could help in developing a better airbag and in the further understanding of ocular traumas. Keywords: airbag, ocular trauma, computer simulation, transsclerally fixated posterior chamber intraocular lens, finite element analysis

  8. [Postoperative ultrasound biomicroscopic evaluation of the tangible position of black diaphragm posterior chamber lenses in congenital and traumatic aniridia in comparison with gonioscopy].

    Science.gov (United States)

    Schweykart, N; Reinhard, T; Engelhardt, S; Sundmacher, R

    1999-06-01

    Ultrasound biomicroscopy (UBM) allows to determine the haptic position of posterior chamber lenses (PCL) in relation to adjacent structures. In transsclerally sutured PCLs, the comparison between intraoperatively endoscopically and postoperatively localized haptic positions via UBM showed a correspondence of only 81%. The different localisation of 19% of the examined haptic positions was explained with postoperative dislocation without any proof for this assumption. The purpose of this study therefore was the correlation of UBM results with simultaneously determined haptic positions via gonioscopy in aniridia after black diaphragm PCL implantation. The haptic positions of black diaphragm PCL implants in 20 patients with congenital and 13 patients with traumatic aniridia were determined via UBM (50-MHz-probe) and gonioscopy 44.4 (6-75) months postoperatively. 39/66 haptic positions could be localized in gonioscopy as well as in UBM. 38 haptics (97.4%) showed the same position in both examination techniques. Determination of the haptic position through one of the two examination techniques was impossible in 27/66 haptics (11 haptics in gonioscopy, 16 haptics in UBM). Reasons for this were primarily haptic position behind iris remnants and corneal opacities in gonioscopy and scarring of the ciliary body in UBM. The validity of UBM in localization of PCLs was confirmed gonioscopically, which also confirms our prior assumption of postoperative displacement of IOL-haptics after transscleral suturing in about 20% of cases. Scarring of the ciliary body was the most important obstacle in the determination of PCL haptic positions in relation to adjacent structures.

  9. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  10. Serial corneal endothelial cell loss with lathe-cut and injection-molded posterior chamber intraocular lenses.

    Science.gov (United States)

    Kraff, M C; Sanders, D R; Lieberman, H L

    1983-01-01

    We compared endothelial cell loss of patients implanted with lathe-cut posterior chamber lenses and those implanted with injection-molded lenses over a three-year postoperative period. Results were based on more than 2,500 measurements of corneal endothelial density. Although the technique of cataract extraction (anterior chamber phacoemulsification, posterior chamber phacoemulsification, or planned extracapsular extraction) significantly affected cell loss (P less than .01), the type of implant (lathe-cut or injection-molded) did not. Significant continuing endothelial cell loss did not occur during the first three postoperative years with injection-molded lenses. There was, however, a statistically significant 7% to 15% additional cell loss after surgery over the first two to three postoperative years with lathe-cut implants. There have been no cases of corneal endothelial decompensation developing after implantation of injection-molded or lathe-cut lenses. Because a standard field clinical specular microscope was used in this study, cell counting errors cannot be ruled out as a cause of these findings.

  11. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients.

    Science.gov (United States)

    Tong, Nianting; Liu, Fuling; Zhang, Ting; Wang, Liangyu; Zhou, Zhanyu; Gong, Huimin; Yuan, Fuxiang

    2017-05-01

    To describe secondary pigment dispersion syndrome (PDS) and pigmentary glaucoma after secondary sulcus transscleral fixation of 1-piece hydrophobic acrylic foldable posterior chamber intraocular lenses (PC IOLs) in aphakic patients in a Chinese population. Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao, China. Retrospective case series. This chart review included eyes that had secondary sulcus transscleral fixation of a 1-piece hydrophobic acrylic foldable PC IOL (Tecnis ZCB00) between March 2011 and March 2014. The patients' demographic data, clinical data, postoperative complications, intervals between initial surgery and the onset of PDS, pigmentary glaucoma occurrences, and findings on slitlamp biomicroscopy, gonioscopy, and ultrasound biomicroscopy (UBM) were recorded. The study comprised 23 consecutive eyes of 21 patients. Seventeen eyes of 16 patients were diagnosed with PDS, and 7 eyes of 6 patients were diagnosed with pigmentary glaucoma. The slitlamp examination and UBM showed that the location between the IOL optic and the posterior surface of the iris was very close. Slitlamp examination of the anterior chamber angle using a gonioscope showed dense pigment deposition on the IOL surfaces. A reverse pupillary block was found in 10 eyes of 9 patients. Other postoperative complications included intraocular hemorrhage, pupillary capture of the IOL optic, IOL tilt, IOL decentration, IOL dislocation, and suture erosion. The 1-piece hydrophobic acrylic foldable PC IOL was not suitable for sulcus transscleral fixation because of a high incidence of PDS and pigmentary glaucoma after surgery in a Chinese population. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Subluxation of iris-sutured intraocular lenses and results of a closed chamber technique for repositioning after penetrating keratoplasty.

    Science.gov (United States)

    Jabbur, Nada S; Akpek, Esen Karamursel; Stark, Walter J

    2005-05-01

    To describe subluxation of iris-fixated intraocular lenses (IOLs) after penetrating keratoplasty (PK) as a postoperative complication and report the long-term outcomes of a closed-chamber refixation technique used in the management. This was a retrospective, noncomparative interventional case series in which 19 consecutive patient charts with a subluxated iris-fixated IOL after PK were retrospectively reviewed. Fourteen of the patients underwent surgery using a closed-chamber refixation technique. These patients were evaluated for visual outcome and surgical complications associated with the procedure. In 13 patients, postoperative follow-up was available. In all 13 cases, the fixated IOL appeared stable and remained well positioned during a follow-up period of 56 months (range, 6-122). All patients (100%) achieved improved uncorrected visual acuity. The postoperative visual acuity ranged from 20/20 to 20/100 with a mean of 20/40. Vitreous hemorrhage occurred in 1 patient, and an additional patient required a second surgery using the same technique. Both of these patients did well with a final visual acuity of 20/40 and 20/50, respectively. Subluxation of iris-fixated IOL after PK can occur as a postoperative complication. The technique that we herein describe enables secure refixation of subluxated IOLs and yields favorable long-term results.

  13. Lente fácica de câmara posterior para correção da miopia Posterior chamber phakic lens for the correction of myopia

    Directory of Open Access Journals (Sweden)

    Ricardo Queiroz Guimarães

    2001-02-01

    Full Text Available Objetivo: Avaliar a eficácia, previsibilidade e segurança do implante de lente intra-ocular de câmara posterior em pacientes com miopia moderada e elevada. Métodos: Analisamos os resultados das cirurgias realizadas em 93 olhos de 54 pacientes para implante de lente fácica de câmara posterior com a finalidade de corrigir miopia moderada e elevada. O objetivo da cirurgia era a emetropia. O acompanhamento médio foi de 9 meses, variando de 1 a 38 meses (desvio padrão 10,45. Resultados: O equivalente esférico médio pré-operatório era -13,56 D (variando de -5,75 a -20,38 D e o equivalente esférico médio pós-operatório no último exame foi -0,92 D (variando de -3,88 a +1,00 D. No último exame, 39 olhos (41,9% se encontravam entre ±0,50 D da emetropia, 64 olhos (68,8% estavam entre ±1,00 D e 88 olhos (94,6% estavam entre ±2,00 D da emetropia. Um ganho de duas ou mais linhas de visão foi observado em 45,17% (42 olhos. Em 15 olhos (16,1% ocorreu algum tipo de complicação: em 2 olhos (2,2% houve perda de células endoteliais, em 2 olhos (2,2% ocorreu bloqueio pupilar e em 11 olhos (11,8% houve alterações de transparência lenticular, assintomática em 5 olhos (5,4% e sintomática em 6 olhos (6,5%. Conclusão: O implante de lente fácica de câmara posterior para correção de miopia moderada e alta é um método eficaz, previsível e seguro. O significativo ganho de linhas de visão é uma observação freqüente nesta técnica. Um acompanhamento pós-operatório mais prolongado em um maior número de pacientes é necessário para confirmar a estabilidade dos resultados a longo prazo.Purpose: To examine the efficacy, predictability and safety of posterior chamber phakic intraocular lens implantation in patients with moderate and high myopia. Methods: We analyzed the results of 93 eyes of 54 patients who were submitted to the implantation of a posterior chamber phakic lens for the correction of their myopia. The target postoperative

  14. Sutureless glueless intrascleral fixation of posterior chamber intraocular lens: Boon for aphakic

    Directory of Open Access Journals (Sweden)

    Nagendra Shekhawat

    2017-01-01

    Full Text Available Purpose: To report results of intrascleral fixation of 3-piece IOL without the help of suture and glue. Methods: Study included intrascleral fixation of haptic in 50 eyes by T-fixation technique. Preoperative and postoperative visual acuity, slit lamp and fundus examination, applanation tonometry, keratometry, biometry, optical coherence tomography, Scheimpflug imaging were done for extensive evaluation. Qualitative and quantitative data were summarized in the form of proportion and mean and standard deviation, respectively. The significance of difference was measured by Chi-square test or unpaired t-test or ANOVA whichever is appropriate. P < 0.05 was considered as statistically significant. Results: There was one case in which haptic broke during handshake maneuver and another IOL was required. Postoperative complications included corneal edema (4%, increased intraocular pressure (6%, cystoid macular edema (2%, decentration (4%, and dislocation (2%, which were all managed to the level of good visual recovery. There was no significant change in corneal astigmatism. There was significant change found in best-corrected visual acuity and uncorrected visual acuity after surgery. Conclusion: This modified technique seems to be a good alternative in IOL implantation in eyes with deficient capsules in view of the decrease in the learning time and surgical time and risk for complications.

  15. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  16. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  17. HANGING BY A THREAD: THE LONG-TERM EFFICACY AND SAFETY OF TRANSSCLERAL SUTURED INTRAOCULAR LENSES IN CHILDREN (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    Science.gov (United States)

    Buckley, Edward G.

    2007-01-01

    Purpose To evaluate the long-term efficacy, safety, and advisability of using transscleral sutured posterior chamber intraocular lenses (IOLs) in pediatric patients with no capsular support and to determine whether 10-0 polypropylene suture should be used for this purpose. Methods A long-term retrospective interventional case series review of 33 eyes of 26 patients who had a sutured IOL at Duke University Eye Center were evaluated for the intraoperative surgical risks, postoperative visual and refractive outcomes, and the number, type, and severity of the postoperative complications. In addition, a survey of pediatric ophthalmologists’ experience with suture breakage was performed. Results Postoperative visual acuity was significantly improved after surgery (P subluxation of the IOL secondary to spontaneous 10-0 polypropylene suture breakage at 3.5, 8, and 9 years after surgery. A survey of pediatric ophthalmologists revealed 10 similar cases (mean, 5 years after surgery). Conclusion Transscleral fixation of an IOL in a child appears to be a safe and effective procedure provided that the suture material used is stable enough to resist significant degradation over time. Caution should be exercised in the use of 10-0 polypropylene suture to fixate an IOL to the sclera in children, and an alternative material or size should be considered. PMID:18427618

  18. Nueva variante de abordaje al surco ciliar en la fijación transescleral de lentes de cámara posterior New variant of approach to the ciliary sulcus in the transcleral fixation of posterior chamber lens

    Directory of Open Access Journals (Sweden)

    Ileana Vila Dópico

    2002-06-01

    Full Text Available Se expone una variante de abordaje al surco ciliar para la fijación del lente intraocular de cámara posterior, que está a nuestro alcance, en pacientes en que no existe soporte capsular o este es insuficiente. Se describe la técnica. Se realizó en 17 pacientes de los que se obtuvo mejoría visual en todos los casos (20/50-20/20 con un seguimiento promedio de 12 meses. Esta variante tiene la ventaja de evitar el paso de la aguja por el surco ciliar a ciegas, pues se utiliza el abordaje a través de la esclera y con ello evitamos dañar estructuras oculares aledañas evitando el riesgo de complicaciones por lo que se logra la recuperación anatómica y funcional en todos los casos.A variant to approach the ciliary sulcus for fixating the posterior chamber intraocular lens, which is within our reach, in patients with insufficient or no capsular support, is explained. The technique is described here and it was applied to 17 patients. Visual improvement was obtained in all cases (20/50-20/20 with an average follow-up of 12 months. This variant allows to prevent the blind passage of the needle through the ciliary sulcus, since it is approached via the sclera, avoiding to damage adjoining ocular structures and to have complications, and making possible the anatomic and functional recovery of all patients.

  19. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Shimizu, Kimiya

    2012-06-01

    A modified implantable collamer lens (ICL) with a central hole (diameter, 0.36 mm), a "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study was to investigate the fluid dynamic characteristics of aqueous humour in a Hole-ICL using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V5 (Mentor Graphics Corp.). For the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. Both ICLs were -9.0 diopters (D) and 12.0 mm in length, with an optic of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μl/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated, and trajectory analysis was performed. The flow velocity 0.25 mm in front of the centre of the crystalline lens was 1.52 × 10(-1) mm/sec for the Hole-ICL and 1.21 × 10(-5) mm/sec for the conventional ICL. Outward flow from the hole in the Hole-ICL was confirmed by trajectory analysis. These results suggest that Hole-ICLs improve the circulation of aqueous humour to the anterior surface of the crystalline lens.

  20. Mechanics of Suture Joints

    Science.gov (United States)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  1. Cranial suture biology of the Aleutian Island inhabitants.

    Science.gov (United States)

    Cray, James; Mooney, Mark P; Siegel, Michael I

    2011-04-01

    Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. Copyright © 2011 Wiley-Liss, Inc.

  2. Ectocranial suture fusion in primates: pattern and phylogeny.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2014-03-01

    Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.

  3. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  4. Suture Coding: A Novel Educational Guide for Suture Patterns.

    Science.gov (United States)

    Gaber, Mohamed; Abdel-Wahed, Ramadan

    2015-01-01

    This study aims to provide a helpful guide to perform tissue suturing successfully using suture coding-a method for identification of suture patterns and techniques by giving full information about the method of application of each pattern using numbers and symbols. Suture coding helps construct an infrastructure for surgical suture science. It facilitates the easy understanding and learning of suturing techniques and patterns as well as detects the relationship between the different patterns. Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. The arrangement is fixed as 1-3-5-7 and a-c-e-g on one side (whether right or left) and as 2-4-6-8 and b-d-f-h on the other side. Needle placement must start from number 1 or letter "a" and continue to follow the code till the end of the stitching. Some rules are created to be adopted for the application of suture coding. A suture trainer containing guide points that simulate the coding process is used to facilitate the learning of the coding method. (120) Is the code of simple interrupted suture pattern; (ab210) is the code of vertical mattress suture pattern, and (013465)²/3 is the code of Cushing suture pattern. (0A1) Is suggested as a surgical suture language that gives the name and type of the suture pattern used to facilitate its identification. All suture patterns known in the world should start with (0), (A), or (1). There is a relationship between 2 or more surgical patterns according to their codes. It can be concluded that every suture pattern has its own code that helps in the identification of its type, structure, and method of application. Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. Coding methods facilitate suture patterns learning process. The use of suture coding can be a good

  5. A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: correlation between ocular biometric parameters.

    Science.gov (United States)

    Ghoreishi, Mohammad; Abdi-Shahshahani, Mehdi; Peyman, Alireza; Pourazizi, Mohsen

    2018-02-21

    The aim of this study was to determine the correlation between ocular biometric parameters and sulcus-to-sulcus (STS) diameter. This was a cross-sectional study of preoperative ocular biometry data of patients who were candidates for phakic intraocular lens (IOL) surgery. Subjects underwent ocular biometry analysis, including refraction error evaluation using an autorefractor and Orbscan topography for white-to-white (WTW) corneal diameter and measurement. Pentacam was used to perform WTW corneal diameter and measurements of minimum and maximum keratometry (K). Measurements of STS and angle-to-angle (ATA) were obtained using a 50-MHz B-mode ultrasound device. Anterior optical coherence tomography was performed for anterior chamber depth measurement. Pearson's correlation test and stepwise linear regression analysis were used to find a model to predict STS. Fifty-eight eyes of 58 patients were enrolled. Mean age ± standard deviation of sample was 28.95 ± 6.04 years. The Pearson's correlation coefficient between STS with WTW, ATA, mean K was 0.383, 0.492, and - 0.353, respectively, which was statistically significant (all P correlation of STS with WTW and mean K and potential of direct and essay measurement of WTW and mean K, it seems that current IOL sizing protocols could be estimating with WTW and mean K.

  6. Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

    Science.gov (United States)

    Kawamorita, Takushi; Shimizu, Kimiya; Shoji, Nobuyuki

    2016-04-01

    A modified implantable collamer lens (ICL) with a central hole with a diameter of 0.36 mm, referred to as a hole-ICL, was created to improve aqueous humour circulation. The aim of this study is to investigate the ideal hole size in a hole-ICL from the standpoint of the fluid dynamic characteristics of the aqueous humour using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V 12.2 (Mentor Graphics Corp.). In the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with a conventional ICL (Model ICM, Staar Surgical) and a hole-ICL were used. The hole-ICL was -9.0 dioptres (D) and 12.0 mm in length, with an optic zone of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μL/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was calculated, and trajectory analysis was performed. With an increase in the central hole size, the velocity of the aqueous humour increased, with the peak velocity occurring at a diameter of approximately 0.4 mm. Once the diameter had increased above 0.4 mm, the velocity then decreased. The velocity difference between the cases of a central hole size of 0.1 mm and 0.2 mm was significant. The desirable central hole size was 0.2 mm or larger in terms of flow dynamics. The current model, based on a central hole size of 0.36 mm, was close to ideal. The optimisation of the hole size should be performed based on results from a long-term clinical study so as to analyse the incidence rate of secondary cataract and optical performance.

  7. Optimal suture anchor direction in arthroscopic lateral ankle ligament repair.

    Science.gov (United States)

    Yoshimura, Ichiro; Hagio, Tomonobu; Noda, Masahiro; Kanazawa, Kazuki; Minokawa, So; Yamamoto, Takuaki

    2017-05-26

    In this study, the distance between the insertion point of the suture anchors and posterior surface of the fibula during arthroscopic lateral ankle ligament repair was investigated on computed tomography (CT) images. The hypothesis of this study was that there is an optimal insertional direction of the suture anchor to avoid anchor-related complications. One hundred eleven ankles of 98 patients who had undergone three-dimensional CT scans for foot or ankle disorders without deformity of the fibula were assessed (59 males, 52 females; median age 25.5 years; age range 12-78 years). The shortest distance from the insertion point of the suture anchor to the deepest point of the fossa/top of the convex aspect of the fibula was measured on the axial plane, tilting from the longitudinal axis of the fibula at 90°, 75°, 60°, and 45°. The distance from the insertion point of the suture anchor to the posterior surface of the fibula was also measured in a direction parallel to the sagittal plane of the lateral surface of the talus on the axial plane, tilting from the longitudinal axis of the fibula at 90°, 75°, 60°, and 45°. The posterior fossa was observed in all cases on the 90° and 75° images. The distance from the insertion point to the posterior surface of the fibula in the parallel direction was 15.0 ± 3.4 mm at 90°, 17.5 ± 3.2 mm at 75°, 21.7 ± 3.3 mm at 60°, and 25.7 ± 3.6 mm at 45°. The posterior points in the parallel direction were located on the posterior fossa in 36.0% of cases at 90°, in 12.6% at 75°, and in 0.0% at 60° and 45°. The suture anchor should be directed from anterior to posterior at an angle of <45° to the longitudinal axis of the fibula, parallel to the lateral surface of the talus, to avoid passing through the fibula. Cohort study, Level III.

  8. Outcomes Associated With Concurrent Iris-Sutured Intraocular Lens Placement and Subluxated Crystalline Lens Extraction.

    Science.gov (United States)

    McClellan, Scott F; Soiberman, Uri; Gehlbach, Peter L; Murakami, Peter N; Stark, Walter J

    2015-08-01

    We have developed a novel surgical technique, to our knowledge, for the management of subluxated crystalline lenses involving preplacement of an iris-sutured posterior chamber intraocular lens (PCIOL) before pars plana vitrectomy and lensectomy. To investigate the outcomes of eyes with subluxated crystalline lenses, predominantly a result of Marfan syndrome (14 eyes [58%]) or trauma (5 eyes [21%]), that underwent pars plana vitrectomy and lensectomy with placement of an iris-sutured PCIOL. We performed a retrospective, noncomparative case series of 24 eyes from 17 consecutive adult patients with surgically treated subluxated crystalline lenses presenting to the Wilmer Eye Institute at Johns Hopkins Hospital from October 6, 2006, through May 1, 2013. The mean (SD) postoperative follow-up was 24.4 (20.5) months for eyes with at least 6 months of follow-up (last date, October 13, 2014). We performed the analysis from January 21, 2014, through January 3, 2015. Improvement in best-corrected visual acuity using an automated Snellen chart and induction of astigmatism for eyes with at least 6 months of follow-up (n = 18) and IOL stability during follow-up for all eyes (n = 24). The mean (SD) age at surgery was 49.4 (10.7 [range, 29-67]) years. We found an improvement in mean (SD [95% CI]) best-corrected visual acuity from 0.66 (0.71 [0.30-1.02]) logMAR preoperatively (Snellen equivalent, approximately 20/90; range, 20/30 to hand motions) to 0.07 (0.11 [95% CI, 0.01-0.12]) logMAR postoperatively (Snellen equivalent, approximately 20/23; range, 20/15 to 20/50). We found little change in astigmatism postoperatively (mean change, -0.1 [95% CI, -0.5 to 0.13] diopters). Postoperative complications included retinal detachment (1 eye [4%]), retained cortical fragment (1 [4%]), cystoid macular edema (2 [8%]), and IOL subluxation (3 [13%]) owing to haptic slippage within 3 months of the procedure. The overall probability of successfully achieving placement of a centered iris-sutured

  9. Bacterial adherence to polymethylmethacrylate posterior chamber IOLs

    Directory of Open Access Journals (Sweden)

    Tyagi Shalini

    2001-01-01

    Full Text Available Purpose: Bacterial adherence to intraocular lenses (IOLs has been incriminated in the pathogenesis of postoperative endophthalmitis. Staphylococcus epidermidis is the most common organism isolated. We studied the in-vitro adhesion of Staphylococcus epidermidis to Polymethylmethacrylate (PMMA IOLs and the effect of duration of exposure to adherence. Methods: Two groups of 10 IOLs each were incubated in Staphylococcus epidermidis suspension for 2 minutes and 20 minutes respectively. Adhesion of bacterial cells was determined by counting the number of viable bacteria attached to IOLs. Results: The mean bacterial adherence with 2 minutes incubation was 12,889 ± 7,150 bacteria / IOL and with 20 minutes incubation was 84,226 ± 35,024 bacteria/IOL (P< 0.01. Conclusion: Our results show that Staphylococcus epidermidis adheres to PMMA IOLs in vitro and the degree of adherence is less for shorter duration of exposure. We conclude that viable bacteria irreversibly adherent to IOLs may play a role in the pathogenesis of postoperative endophthalmitis. Shorter duration of operative manipulation and exposure to contaminating sources may decrease the chances of postoperative endophthalmitis.

  10. The history of barbed sutures.

    Science.gov (United States)

    Ruff, Gregory L

    2013-09-01

    Ligatures have been used for millennia to close wounds. Sterilization and synthetic polymers that degrade in a commensurate fashion with wound healing have been the most significant improvements in these age-old devices. However, the constricting loop of a traditional suture and subsequent ischemia ("approximate, don't strangulate") still account for the most common cause of wound dehiscence-necrosis. Inspired by the quill of the North American porcupine, I envisioned a bidirectional array of barbs that could secure tissue without relying on constricting loops. One set of barbs could anchor the other. In this article, I document the development process of these barbed sutures from concept to patent to manufacture and US Food and Drug Administration approval. Knotless, strong, and easy to place, barbed sutures could foreseeably supplant conventional sutures, particularly as endoscopic procedures become more common. They also offer the intriguing potential to suspend ptotic tissues without surgical intervention.

  11. Ameloblastin inhibits cranial suture closure by modulating MSX2 expression and proliferation.

    Directory of Open Access Journals (Sweden)

    Phimon Atsawasuwan

    Full Text Available Deformities of cranial sutures such as craniosynostosis and enlarged parietal foramina greatly impact human development and quality of life. Here we have examined the role of the extracellular matrix protein ameloblastin (Ambn, a recent addition to the family of non-collagenous extracellular bone matrix proteins, in craniofacial bone development and suture formation. Using RT-PCR, western blot and immunohistochemistry, Ambn was localized in mouse calvarial bone and adjacent condensed mesenchyme. Five-fold Ambn overexpression in a K14-driven transgenic mouse model resulted in delayed posterior frontal suture fusion and incomplete suture closure. Moreover, Ambn overexpressor skulls weighed 13.2% less, their interfrontal bones were 35.3% thinner, and the width between frontal bones plus interfrontal suture was 14.3% wider. Ambn overexpressing mice also featured reduced cell proliferation in suture blastemas and in mesenchymal cells from posterior frontal sutures. There was a more than 2-fold reduction of Msx2 in Ambn overexpressing calvariae and suture mesenchymal cells, and this effect was inversely proportionate to the level of Ambn overexpression in different cell lines. The reduction of Msx2 expression as a result of Ambn overexpression was further enhanced in the presence of the MEK/ERK pathway inhibitor O126. Finally, Ambn overexpression significantly reduced Msx2 down-stream target gene expression levels, including osteogenic transcription factors Runx2 and Osx, the bone matrix proteins Ibsp, ColI, Ocn and Opn, and the cell cycle-related gene CcnD1. Together, these data suggest that Ambn plays a crucial role in the regulation of cranial bone growth and suture closure via Msx 2 suppression and proliferation inhibition.

  12. Single-suture scleral fixation of subluxated foldable intraocular lenses.

    Science.gov (United States)

    Yarangumeli, Alper; Alp, Mehmet Numan; Kural, Gulcan

    2012-01-01

    To evaluate the results of single-suture scleral fixation of subluxated foldable intraocular lenses (IOL) in eyes with sufficient residual capsular support. The results of IOL repositioning by single-suture scleral fixation in 6 eyes of 6 patients with IOL subluxation were included. All subluxated IOLs were single-piece hydrophilic acrylic. Subluxation resulted from posterior capsule tears in 3 eyes, zonular dialyses in 2 eyes, and zonular dialysis with a capsulorhexis tear in 1 eye. A similar technique was used in all eyes in which one haptic was externalized through a superior clear corneal incision and tied with a Pair-PAK 10-0 polypropylene suture, and was finally retracted and fixated behind the iris close to the ciliary sulcus at the 12:00 meridian. All patients were followed up for at least 6 months. Best-corrected visual acuities ranged between finger counting and 20/70 (mean logMAR 1.02±0.64) preoperatively, and between 20/100 and 20/20 (mean logMAR 0.22±0.26) at the final postoperative visit. All IOLs remained centered and no significant postoperative complications were encountered except for an IOL tilt which resulted in a considerable oblique astigmatism in one eye. Subluxated foldable IOLs may safely be repositioned and secured with a single scleral fixation suture in selected cases with adequate amount of capsular remnants.

  13. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  14. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  15. Radiological assessment of skull base changes in children with syndromic craniosynostosis: role of ''minor'' sutures

    International Nuclear Information System (INIS)

    Calandrelli, Rosalinda; D'Apolito, Gabriella; Gaudino, Simona; Stefanetti, Mariangela; Colosimo, Cesare; Massimi, Luca; Di Rocco, Concezio

    2014-01-01

    This study aims to identify the premature synostosis of ''major'' and ''minor'' sutures of the four ''sutural arches'' of the skull and to perform a morphometric analysis in children with syndromic craniosynostosis in order to evaluate changes in the skull base linked with premature suture synostosis. We reviewed multiplanar high-resolution CT images, implemented with 3D reconstructions, from 18 patients with complex syndromic craniosynostosis and compared them with 18 age-matched healthy subjects. We assessed the calvarial sutures and their extension to the skull base, and then we correlated specific types of synostosis with the size, shape and symmetry of the cranial fossae. We found a marked asymmetry of the skull base growth in all patients. The synostotic involvement around the coronal ring caused a reduction in the growth of the anterior and middle fossae. The size of the posterior cranial fossa was related not only to ''major'' but also to ''minor'' suture synostosis of the lambdoid and parieto-squamosal arches. Changes in the skull base and craniofacial axis symmetry are due to structural and functional relationships between ''major'' and ''minor'' skull sutures, suggesting a structural and functional relationship between the neurocranium and basicranium. The early recognition of prematurely closed skull base sutures may help clinicians and neurosurgeons to establish correct therapeutic approaches. (orig.)

  16. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture.

    LENUS (Irish Health Repository)

    Hennessey, D B

    2012-08-01

    A continuous running suture is the preferential method for abdominal closure. In this technique the suture is secured with an initial knot and successive tissue bites are taken. At each tissue bite, the needle is rotated through the tissue; in doing so, the suture can twist around the knot which acts as an anchor.

  17. Treatment of chronic deltoid ligament injury using suture anchors.

    Science.gov (United States)

    Wang, Xu; Ma, Xin; Zhang, Chao; Wang, Chen; Huang, Jia-zhang

    2014-08-01

    To explore the efficacy of overlapping suture-anchor fixation for treatment of chronic deltoid ligament injury. Seventeen patients (11 men, 6 women of mean age 32.1 years [range, 18-58 years]) who had undergone surgery for chronic deltoid ligament injury from January 2007 to December 2011 were retrospectively analyzed. Preoperatively, they had undergone bilateral weight-bearing posterior-anterior radiographs, (MRI) and ultrasound examinations of the ankle. Ankle arthroscopy was performed to confirm the diagnosis, followed by surgery to clear intra-articular proliferating synovial tissues and remove cartilage debris and scar tissue. The deep layer of the deltoid ligament was sutured onto the tip of the medial malleolus and its superficial layer sutured onto its periosteum and fixed with suture anchors. American Orthopedic Foot and Ankle Society (AOFAS) scoring system for the ankle-hindfoot was used to evaluate the ankles pre- and post-operatively. The 17 patients were followed up for 12-34 months (mean 20.1 months). The angle between the long axes of the talus and first metatarsal and the hindfoot angle measured in a hindfoot alignment view (as described by Saltzman) were reduced from 5.4° ± 1.8° and 8.2° ± 2.6° preoperatively to 4.0° ± 0.9° and 5.3° ± 1.3° postoperatively, respectively. The mean AOFAS ankle-hindfoot score was 76.8 ± 7.0 preoperatively and 94.1 ± 3.3 at the last follow-up visit. Ten patients were scored as excellent, six as good, and one as fair. Pain was relieved in all patients and no patients had recurrent deltoid ligament injury. Using suture anchors to treat chronic deltoid ligament injury has relatively satisfactory outcomes. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  18. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. [Laparoscopic suture or open suture in perforated duodenal ulcer].

    Science.gov (United States)

    Nicolau, A E; Ionescu, G; Iordache, F; Mehic, R; Spătaru, A

    2002-01-01

    Between Nov. 1994-Jan. 2001 we performed laparoscopic suture with omentoplasty of perforated duodenal ulcer (PDU) in 51 patients out of 56 it was intended (this constituted the laparoscopic group--LG). The selection criteria were young patients, age < 40 years, no associated diseases, onset of the operation under 12 hours from the occurrence of the perforation, absence of clear ulcer history. In the same period, we performed an open suture based on the same criteria in 105 patients (open group--OP). The results showed a difference between needed analgesia (2.8 days for LG vs. 5.2 days for OG) and a hospital stay of 6.1 days in LG vs. 7.7 days in OG. The incidence of postoperative complications was 5.88% in the LG and 7.61% in the OG with 1.96% and respective 1.90% reoperation rate. In conclusion laparoscopic suture of PDU with associated postoperative modern therapy of ulcer disease could be the treatment of choice in young patients.

  20. [Bases and methods of suturing].

    Science.gov (United States)

    Vogt, P M; Altintas, M A; Radtke, C; Meyer-Marcotty, M

    2009-05-01

    If pharmaceutic modulation of scar formation does not improve the quality of the healing process over conventional healing, the surgeon must rely on personal skill and experience. Therefore a profound knowledge of wound healing based on experimental and clinical studies supplemented by postsurgical means of scar management and basic techniques of planning incisions, careful tissue handling, and thorough knowledge of suturing remain the most important ways to avoid abnormal scarring. This review summarizes the current experimental and clinical bases of surgical scar management.

  1. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  2. [Suture simulator - Cleft palate surgery].

    Science.gov (United States)

    Devinck, F; Riot, S; Qassemyar, A; Belkhou, A; Wolber, A; Martinot Duquennoy, V; Guerreschi, P

    2017-04-01

    Cleft palate requires surgery in the first years of life, furthermore repairing anatomically the soft and hard palate is complex on a surgical level because of the fine tissues and the local intraoral configuration. It is valuable to train first on simulators before going to the operating room. However, there is no material dedicated to learning how to perform intraoral sutures in cleft palate surgery. We made one, in an artisanal manner, in order to practice before the real surgical gesture. The simulator was designed based on precise anatomical data. A steel pipe, fixed on a rigid base represented the oral cavity. An adapted split spoon represented the palate. All pieces could be removed in order to apply a hydrocellular dressing before training for sutures. Our simulator was tested by 3 senior surgeons in our department in close to real-life conditions in order to evaluate its anatomical accuracy. It is valuable to have a simulator to train on cleft palate sutures within teaching university hospitals that manage this pathology. Our simulator has a very low cost, it is easy to make and is anatomically accurate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  4. Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

    Science.gov (United States)

    Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric

    2013-08-01

    The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.

  5. Tibial avulsion fracture of the posterior root of the medial meniscus in children

    DEFF Research Database (Denmark)

    Iversen, Jonas Vestergård; Krogsgaard, Michael Rindom

    2012-01-01

    of displaced avulsion fractures of the posterior root of the medial meniscus in children are presented along with a concise report of the literature regarding avulsion fractures of the posterior root of the medial meniscus. Both avulsions were reattached arthroscopically by trans-tibial pull-out sutures...

  6. Symbol "&" suture to control atonic postpartum hemorrhage with placenta previa accreta.

    Science.gov (United States)

    Li, Guang Tai; Li, Xiao Fan; Liu, Ya Jing; Li, Wei; Xu, Hong Mei

    2015-02-01

    To evaluate the efficacy and safety of a symbol "&" compression suture technique in controlling severe atonic postpartum hemorrhage with placenta previa accreta during cesarean delivery. Nine women with heavy postpartum bleeding from uterine inertia and placenta previa percret, which did not react to conventional initial management protocols, were underwent the suture in the shape of symbol "&" in China Meitan General Hospital. The suture procedure was to staple the anterior and posterior walls (of the lower uterine segment as well as corpus uterus) together using number 1 chromic catgut, with a cross at about 2 cm above the upper boundary of lower uterine segment. Symbol "&" compression suture was capable of stanching the postpartum hemorrhage immediately in all nine women. None of these patients developed complications related to this method. Subsequent pregnancies after the suture were occurred in two women and delivered with repeat cesarean section. Symbol "&" compression suture is a simple, safe and highly effective technique to control the treatment-resistant uterine atonic bleeding, particularly in previous cesarean scar at lower segment and placenta previa accreta.

  7. Suture spanning augmentation of single-row rotator cuff repair: a biomechanical analysis.

    Science.gov (United States)

    Early, Nicholas A; Elias, John J; Lippitt, Steven B; Filipkowski, Danielle E; Pedowitz, Robert A; Ciccone, William J

    2017-02-01

    This in vitro study evaluated the biomechanical benefit of adding spanning sutures to single-row rotator cuff repair. Mechanical testing was performed to evaluate 9 pairs of cadaveric shoulders with complete rotator cuff repairs, with a single-row technique used on one side and the suture spanning technique on the other. The spanning technique included sutures from 2 lateral anchors securing tendon near the musculotendinous junction, spanning the same anchor placement from single-row repair. The supraspinatus muscle was loaded to 100 N at 0.25 Hz for 100 cycles, followed by a ramp to failure. Markers and a video tracking system measured anterior and posterior gap formation across the repair at 25-cycle intervals. The force at which the stiffness decreased by 50% and 75% was determined. Data were compared using paired t-tests. One single-row repair failed at row repairs than for the suture spanning technique. The difference was statistically significant at all cycles for the posterior gap formation (P ≤ .02). The trends were not significant for the anterior gap (P ≥ .13). The loads at which the stiffness decreased by 50% and 75% did not differ significantly between the 2 types of repair (P ≥ .10). The suture spanning technique primarily improved posterior gap formation. Decreased posterior gap formation could reduce failure rates for rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Drift chamber

    International Nuclear Information System (INIS)

    Inagaki, Yosuke

    1977-01-01

    Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)

  9. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. The suspension (Frost) suture: experience and applications.

    Science.gov (United States)

    Connolly, Karen L; Albertini, John G; Miller, Christopher J; Ozog, David M

    2015-03-01

    The Frost suture is a well-known surgical technique for providing upward tension on the lower lid to prevent or correct ectropion after surgical interventions in the periorbital area. Despite its relatively common use, comprehensive information on executing this technique is not readily available. To review eyelid anatomy, indications, and proper technique for performing the Frost suture, as well as potential complications. A review of the literature on Frost sutures was performed. Cadaveric dissection was performed to demonstrate placement of the Frost suture. The Frost suture is a useful method to reduce the risk of ectropion after surgery near the lower eyelid. Downward pull on the lid can occur with normal wound contracture even if ectropion is not present with the initial repair, reinforcing the need for preventive measures. Potential complications of this technique include superficial skin erosion of the upper lid, corneal abrasion, and blockage of the field of vision while the suture is in place.

  12. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  13. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  14. Comparison between suture anchor and transosseous suture for the modified-Broström procedure.

    Science.gov (United States)

    Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin

    2012-06-01

    This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.

  15. Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.

    Science.gov (United States)

    Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen

    2017-07-01

    Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.

  16. Radiological assessment of skull base changes in children with syndromic craniosynostosis: role of ''minor'' sutures

    Energy Technology Data Exchange (ETDEWEB)

    Calandrelli, Rosalinda; D' Apolito, Gabriella; Gaudino, Simona; Stefanetti, Mariangela; Colosimo, Cesare [Universita Cattolica Sacro Cuore, Institute of Radiology, Rome (Italy); Massimi, Luca; Di Rocco, Concezio [Universita Cattolica Sacro Cuore, Institute of Neurosurgery, Rome (Italy)

    2014-10-15

    This study aims to identify the premature synostosis of ''major'' and ''minor'' sutures of the four ''sutural arches'' of the skull and to perform a morphometric analysis in children with syndromic craniosynostosis in order to evaluate changes in the skull base linked with premature suture synostosis. We reviewed multiplanar high-resolution CT images, implemented with 3D reconstructions, from 18 patients with complex syndromic craniosynostosis and compared them with 18 age-matched healthy subjects. We assessed the calvarial sutures and their extension to the skull base, and then we correlated specific types of synostosis with the size, shape and symmetry of the cranial fossae. We found a marked asymmetry of the skull base growth in all patients. The synostotic involvement around the coronal ring caused a reduction in the growth of the anterior and middle fossae. The size of the posterior cranial fossa was related not only to ''major'' but also to ''minor'' suture synostosis of the lambdoid and parieto-squamosal arches. Changes in the skull base and craniofacial axis symmetry are due to structural and functional relationships between ''major'' and ''minor'' skull sutures, suggesting a structural and functional relationship between the neurocranium and basicranium. The early recognition of prematurely closed skull base sutures may help clinicians and neurosurgeons to establish correct therapeutic approaches. (orig.)

  17. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...

  18. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  19. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Post thyroidectomy suture granuloma: a cytological diagnosis.

    Science.gov (United States)

    Javalgi, Anita P; Arakeri, Surekha U

    2013-04-01

    There are known post thyroidectomized complications, a suture granuloma being less frequent, with its late complication mimicking recurrent thyroid cancer. A suture granuloma is a benign, granulomatous inflammatory reaction that occurs due to the use of non absorbable suture. It constitutes one of the late complications which altogether make up less than 2% of its incidence. A suture granuloma is similar to a foreign body reaction and it usually develops slowly as a painless, palpable asymptomatic mass over the years. It mimics a cancer recurrence or a lymph node metastasis. Here, we are reporting a case of a post thyroidectomy suture granuloma in a 46 years old lady who presented with a painless swelling in the lateral neck, with a past history of thyroidectomy 5 years back.

  3. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging

    Directory of Open Access Journals (Sweden)

    Daniele Cantarella

    2017-11-01

    Full Text Available Abstract Background Mini-implant-assisted rapid palatal expansion (MARPE appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME. Maxillary Skeletal Expander (MSE is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Methods Fifteen subjects (mean age of 17.2 years; range, 13.9–26.2 years were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher’s exact test was used. Results Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS and at posterior nasal spine (PNS was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05. No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and

  4. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging.

    Science.gov (United States)

    Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won

    2017-11-01

    Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05). No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0

  5. A multicenter randomized controlled trial comparing absorbable barbed sutures versus conventional absorbable sutures for dermal closure in open surgical procedures.

    Science.gov (United States)

    Rubin, J Peter; Hunstad, Joseph P; Polynice, Alain; Gusenoff, Jeffrey A; Schoeller, Thomas; Dunn, Raymond; Walgenbach, Klaus J; Hansen, Juliana E

    2014-02-01

    Barbed sutures were developed to reduce operative time and improve security of wound closure. The authors compare absorbable barbed sutures (V-Loc, Covidien, Mansfield, Massachusetts) with conventional (smooth) absorbable sutures for soft tissue approximation. A prospective multicenter randomized study comparing barbed sutures with smooth sutures was undertaken between August 13, 2009, and January 31, 2010, in 241 patients undergoing abdominoplasty, mastopexy, and reduction mammaplasty. Each patient received barbed sutures on 1 side of the body, with deep dermal sutures eliminated or reduced. Smooth sutures with deep dermal and subcuticular closure were used on the other side as a control. The primary endpoint was dermal closure time. Safety was assessed through adverse event reporting through a 12-week follow-up. A total of 229 patients were ultimately treated (115 with slow-absorbing polymer and 114 with rapid-absorbing polymer). Mean dermal closure time was significantly quicker with the barbed suture compared with the smooth suture (12.0 vs 19.2 minutes; P<.001), primarily due to the need for fewer deep dermal sutures. The rapid-absorbing barbed suture showed a complication profile equivalent to the smooth suture, while the slow-absorbing barbed suture had a higher incidence of minor suture extrusion. Barbed sutures enabled faster dermal closure quicker than smooth sutures, with a comparable complication profile. 1.

  6. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    Science.gov (United States)

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.

  7. On the roentgenomorphological correlations of cranial sutures

    International Nuclear Information System (INIS)

    Verkhoglyadova, T.P.; Koval', G.Yu.; Shuaa, T.I.

    1986-01-01

    The authors explain the essence of the zone of excessive transparence along the cranial sutures visualized on the X-ray pictures during the first year of life by presence of large number of rough-fiber bone in the marginal regions. The zone of ''physiological sclerosis'' is postulated as a result of summation of the bone margin shadows consisting of compact substance (osteones). Microscopic examination of skull in brain tumors revealed a delay in the formation of bone margins in the suture region with an excessive amount of connective and osteoid tissue while in craniostenosis closure of cranial sutures being with intensive bone formation as well as by closure of the bone margins by newly formed bone tissue around the vessels of the connective layer of the suture

  8. Application analysis on different suture of scleral flap in trabeculectomy

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2014-05-01

    Full Text Available AIM: To research the application of scleral flap suture in trabeculectomy. METHODS: Totally 114 primary angle-closure glaucoma patients, aged from 36-72 years old, were selected as the objects, and randomly divided into research group and control group. The two groups received different administration methods. Traditional sewing method of sclera flap was used in research group and improved sewing method of sclera flap was used in control group. RESULTS: There was statistical differences between postoperative intraocular pressure of the patients in the observation group and the control group after 1d; 2wk; 1, 3mo(PPP>0.05.CONCLUSION: It is safe and effective that the improved sewing method of sclera flap for trabeculectomy of acute angle-closure glaucoma, and it is a better method to avoid the occurrence of shallow anterior chamber than the traditional sewing method in the early stage after operation.

  9. Modified method for bronchial suture by Ramirez Gama compared to separate stitches suture: experimental study

    Directory of Open Access Journals (Sweden)

    Vitor Mayer de Moura

    Full Text Available OBJECTIVE: To experimentally compare two classic techniques described for manual suture of the bronchial stump. METHODS: We used organs of pigs, with isolated trachea and lungs, preserved by refrigeration. We dissected 30 bronchi, which were divided into three groups of ten bronchi each, of 3mm, 5mm, and 7mm, respectively. In each, we performed the suture with simple, separated, extramucosal stitches in five other bronchi, and the technique proposed by Ramirez and modified by Santos et al in the other five. Once the sutures were finished, the anastomoses were tested using compressed air ventilation, applying an endotracheal pressure of 20mmHg. RESULTS: the Ramirez Gama suture was more effective in the bronchi of 3, 5 and 7 mm, and there was no air leak even after subjecting them to a tracheal pressure of 20mmHg. The simple interrupted sutures were less effective, with extravasation in six of the 15 tested bronchi, especially in the angles of the sutures. These figures were not significant (p = 0.08. CONCLUSION: manual sutures of the bronchial stumps were more effective when the modified Ramirez Gama suture was used in the caliber bronchi arms when tested with increased endotracheal pressure.

  10. Chamber transport

    International Nuclear Information System (INIS)

    Olson, Craig L.

    2001-01-01

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system

  11. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  12. A randomized clinical trial of knotless barbed suture vs conventional suture for closure of the uterine incision at cesarean delivery.

    Science.gov (United States)

    Peleg, David; Ahmad, Ronan Said; Warsof, Steven L; Marcus-Braun, Naama; Sciaky-Tamir, Yael; Ben Shachar, Inbar

    2018-03-01

    Knotless barbed sutures are monofilament sutures with barbs cut into them. These sutures self-anchor, maintaining tissue approximation without the need for surgical knots. The hypothesis of this study was that knotless barbed suture could be used on the myometrium to close the hysterotomy at cesarean delivery. The objective was to compare uterine closure time, need for additional sutures, and blood loss between this and a conventional suture. This was a prospective, unblinded, randomized controlled trial conducted at the Ziv Medical Center, Zefat, Israel. The primary outcome was the length of time needed to close the uterine incision, which was measured from the start of the first suture on the uterus until obtaining uterine hemostasis. To minimize provider bias, women were randomized by sealed envelopes that were opened in the operating room just prior to uterine closure with either a bidirectional knotless barbed suture or conventional suture. Secondary outcomes included the number of additional hemostatic sutures needed and blood loss during incision closure. Patients were enrolled from August 2016 until March 2017. One hundred two women were randomized. Fifty-one had uterine closure with knotless barbed suture and 51 with conventional suture. The groups were similar for demographics as well as number of previous cesarean deliveries. Uterine closure time using the knotless barbed suture was significantly shorter than the conventional suture by a mean of 1 minute 43 seconds (P barbed sutures were associated with a lower need for hemostatic sutures (median 0 vs 1, P barbed suture is a reasonable alternative to conventional sutures because it reduced the closure time of the uterine incision. There was also less need for additional hemostatic sutures and slightly reduced estimated blood loss. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Cauterization technique for suture erosion in transscleralfixation of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Xu-Ting Hu

    2013-12-01

    Full Text Available Transscleral suturing is a commonly applied technique to fix intraocular implants in the sulcus. A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result in an increased incidence of endophthalmitis. Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation. This is a simple, quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.

  14. Achondroplasia with multiple-suture craniosynostosis: a report of a new case of this rare association.

    Science.gov (United States)

    Bessenyei, Beáta; Nagy, Andrea; Balogh, Erzsébet; Novák, László; Bognár, László; Knegt, Alida C; Oláh, Eva

    2013-10-01

    We report on a female patient with an exceedingly rare combination of achondroplasia and multiple-suture craniosynostosis. Besides the specific features of achondroplasia, synostosis of the metopic, coronal, lambdoid, and squamosal sutures was found. Series of neurosurgical interventions were carried out, principally for acrocephaly and posterior plagiocephaly. The most common achondroplasia mutation, a p.Gly380Arg in the fibroblast growth factor receptor 3 (FGFR3) gene, was detected. Cytogenetic and array CGH analyses, as well as molecular genetic testing of FGFR1, 2, 3 and TWIST1 genes failed to identify any additional genetic alteration. It is suggested that this unusual phenotype is a result of variable expressivity of the common achondroplasia mutation. Copyright © 2013 Wiley Periodicals, Inc.

  15. Characterization of the bending strength of craniofacial sutures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Whyne, Cari M

    2013-03-15

    The complex, thin and irregular bones of the human craniofacial skeleton (CFS) are connected together through bony articulations and connective tissues. These articulations are known as sutures and are commonly divided into two groups, facial and cranial sutures, based on their location in the CFS. CFS sutures can exhibit highly variable degrees of interdigitation and complexity and are believed to play a role in accommodating the mechanical demands of the skull. This study aimed to evaluate the mechanical behavior of CFS bone samples with and without sutures and to determine the effect of sutural interdigitations on mechanical strength. Sagittal, coronal, frontozygomatic and zygomaticotemporal sutures along with adjacent bone samples not containing sutures were excised from six fresh-frozen cadaveric heads. The interdigitation of the sutures was quantified through μCT based analysis. Three-point bending to failure was performed on a total of 29 samples. The bending strength of bone samples without sutures demonstrated a non-significant increase of 14% as compared to samples containing sutures (P=0.2). The bending strength of bones containing sutures was positively correlated to the sutural interdigitation index (R=0.701, P=0.002). The higher interdigitation indices found in human cranial vs. facial sutures may be present to resist bending loads as a functional requirement in protecting the brain. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Palatoplasty: suturing the mucoperiosteal flaps to the hard palate through hole.

    Science.gov (United States)

    Hwang, Kun; Lee, Ji Hun; Kim, Yu Jin; Le, Se Il

    2009-05-01

    We satisfactorily repaired a wide cleft palate using a method of V-Y pushback and anchoring the oral mucoperiosteal flap onto the bony ridge of the cleft. An 8-year-old Vietnamese girl had a wide incomplete bilateral posterior cleft palate associated with congenital cardiac malformations. The gap of the posterior cleft was 2.5 cm, which exceeded the total widths of the palatal shelves. We applied V-Y pushback and used a vomer flap to close the wide cleft palate. The posterior two thirds of the nasal mucosae from the cleft margins were sutured to the vomer flap. The nasal side of the anterior one third of the bony cleft was uncovered. The elevated bilateral mucoperiosteal flaps were brought together to the midline and sutured to the anterior triangular flap in a V-Y pushback fashion. Four holes were drilled 5 mm lateral to each bony cleft margin. The lateral sides of the mucoperiosteal flaps were fixed to the palate bone with 3-0 Vicryl through the hole. This method reduces the tension of the flap which might frequently cause oronasal fistula and also improve viability.

  17. Comparison of suture types in the closure of scalp wounds.

    LENUS (Irish Health Repository)

    Bonham, Joseph

    2011-06-01

    Innovation in practice can benefit patients and healthcare providers but must be evidence based. This article describes a quantitative study of whether absorbable sutures are as beneficial as non-absorbable sutures in the management of simple scalp lacerations in adults. The results suggest that absorbable sutures can provide the same cosmetic and functional results as non-absorbable sutures. Their use can also reduce patient returns and save money and resources.

  18. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  19. Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model.

    Science.gov (United States)

    Goschka, Andrew M; Hafer, Jason S; Reynolds, Kirk A; Aberle, Nicholas S; Baldini, Todd H; Hawkins, Monica J; McCarty, Eric C

    2015-10-01

    To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomechanical performance of supraspinatus repairs using an all-suture anchor when compared to traditional solid-body suture anchors. Using nine shoulders per group, the supraspinatus tendon was dissected from the greater tuberosity. The four different double row repairs tested were (medial row/lateral row): A: ICONIX2/ICONIX2; B: ICONIX2/Stryker ReelX 3.9mm; C: ICONIX2/Stryker ReelX 4.5mm; D: Arthrex BioComposite CorkScrew FT 4.5mm/Arthrex BioComposite SwiveLock 4.75mm. The ICONIX2 was the only all-suture anchor tested. Tendons underwent cyclic loading from 10 to 100N for 500 cycles, followed by load-to-failure. Data was collected at cycles 5, 100, 200, 300, 400, and 500. One-way ANOVA analysis was used to assess significance (P≤0.05). The anchor combinations tested did not differ significantly in anterior (P>0.4) or posterior (P>0.3) gap formation, construct stiffness (P>0.7), ultimate load (P=0.06), or load to 5mm gap formation (P=0.84). The all-suture anchor demonstrated comparable biomechanical performance in multiple double-row anchor combinations to a combination of traditional solid-body anchors. Thus it may be an attractive option to further reduce the invasiveness of rotator cuff repairs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Posterior muscolofascial reconstruction incorporated into urethrovescical anastomosis during robot-assisted radical prostatectomy.

    Science.gov (United States)

    Ficarra, Vincenzo; Gan, Melanie; Borghesi, Marco; Zattoni, Fabio; Mottrie, Alexandre

    2012-12-01

    The rationale of posterior musculofascial plate reconstruction during radical prostatectomy is to shorten the time to reach urinary continence recovery and to reduce the risk of bleeding and anastomosis leakage. We describe our original technique incorporating the posterior muscolofascial reconstruction into urethrovesical anastomosis using robot-assisted radical prostatectomy (RARP). For this reconstructive step, we use a 30-cm V-Loc 90 3-0 barbed suture (V-20 tapered needle). Specifically, the free edge of the posterior layer of the Denonvilliers fascia is approximated to the posterior part of the sphincteric apparatus in a running fashion from left to right. The musculature of the urethral wall is incorporated in this first layer of the running suture. This suture is then continued back to the left in a second layer incorporating the anterior layer of the Denonvilliers fascia (or prostatovesical muscle), the bladder neck, and again the urethra, this time also with urethral mucosa. The urethrovesical anastomosis is completed using a second running barbed suture (15-cm V-Loc 90 3-0 barbed suture, V-20 tapered needle). No intraoperative complications were observed during this step of the procedure. Anastomotic leakages were observed only in 2% of cases. Only 12.5% showed urinary incontinence after catheter removal (1-2 pads). At mean follow-up of 9 months, the urinary continence recovery was 95%, and an anastomosis stricture necessitating an endoscopic incision developed in only three (1.5%) patients. Recent systematic reviews of the literature showed only a minimal advantage in favor of posterior musculofascial reconstruction in terms of urinary continence recovery within 1 month after radical prostatectomy. We support the use of this step of RARP because it is simple, reproducible, with a very limited increase in operative time, and with only a slight risk of potential harm to the patient. Moreover, it could improve hemostasis and provide greater support for a

  1. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... surgical gut suture. (a) Identification. An absorbable surgical gut suture, both plain and chromic, is an...

  2. Tutoring Trainees to Suture: An Alternative Method for Learning How to Suture and a Way to Compensate for a Lack of Suturing Cases.

    Science.gov (United States)

    Wongkietkachorn, Apinut; Rhunsiri, Peera; Boonyawong, Pangpoom; Lawanprasert, Attaporn; Tantiphlachiva, Kasaya

    2016-01-01

    Tutoring in suturing was developed to compensate for a shortage of suturing cases. The objective of this study was to compare ideal suturing score (ISS; 9 points), suturing time (min:sec), and suture placement error (mm) between medical students completing the suturing tutoring program and medical students attending ordinary medical school training program. Participants consisted of 2 groups of medical students who had never performed suturing. The study group had the role of suturing tutor to teach interested high school students. The control group consisted of volunteers from the ordinary medical school program. Skills measurement was performed by having students from both the groups perform 3 vertical mattress sutures on a model. The study group was tested at weeks 1, 9, and 10 to assess improvement. Both the groups were tested at week 10 to compare final learning outcome. There were 41 and 40 participants in the study group and the control group, respectively. ISS was significantly improved in the study group from week 1-week 10 (7.0 ± 1.3 vs. 8.2 ± 0.9, p = 0.01). At week 10, the study group had a higher mean ISS than the control group (8.2 ± 0.9 vs. 7.8 ± 1.1, p = 0.68). Mean suturing time and mean placement error were also lower in the study group at the end of suturing training (5:1 ± 1:0 vs. 5:2 ± 1:2, p = 0.13; 7.4 ± 7.4 vs. 8.0 ± 10.8, p = 0.44). Tutoring trainees to suture can improve a student's ability to learn how to suture. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  4. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  5. Posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Kushner, M.J.; Luken, M.G. III

    1983-01-01

    CT demonstrated posterior fossa epidural hematoma in three patients with head trauma in whom this diagnosis was not clinically apparent. No patient was in stupor or coma and no patient experienced a lucid interval. Only one patient had signs referable to the posterior fossa. Two patients had occipital skull fracture disclosed by plain radiographs. CT revealed a unilateral biconvex hematoma in two cases, and a bilateral hematoma with supratentorial extension in the third. All patients underwent suboccipital craniectomy and recovered. Therapeutic success in these cases was facilitated by early CT and the rapid disclosure of the unsuspected posterior fossa lesions. CT showing contiguous hematoma below and above the tentorium cerebelli after posterior head trauma is highly suggestive of epidural hematoma arising from the posterior fossa. (orig.)

  6. Deployment and testing of a second prototype expandable surgical chamber in microgravity

    Science.gov (United States)

    Markham, Sanford M.; Rock, John A.

    1991-01-01

    During microgravity exposure, two separate expandable surgical chambers were tested. Both chambers had been modified to fit the microgravity work station without extending over the sides of the table. Both chambers were attached to a portable laminar flow generator which served two purposes: to keep the chambers expanded during use; and to provide an operative area environment free of contamination. During the tests, the chambers were placed on various parts of a total body moulage to simulate management of several types of trauma. The tests consisted of cleansing contusions, debridement of burns, and suturing of lacerations. Also, indigo carmine dye was deliberately injected into the chamber during the tests to determine the ease of cleansing the chamber walls after contamination by escaping fluids. Upon completion of the tests, the expandable surgical chambers were deflated, folded, and placed in a flattened state back into their original containers for storage and later disposal. Results are briefly discussed.

  7. Comparison of barbed unidirectional suture with figure-of-eight standard sutures in vaginal cuff closure in total laparoscopic hysterectomy.

    Science.gov (United States)

    Karacan, Tolga; Ozyurek, Eser; Usta, Taner; Odacilar, Eylem; Hanli, Ulviye; Kovalak, Ebru; Dayan, Huseyin

    2018-03-24

    The aim of the study was to compare postoperative vaginal cuff complications due to the use of barbed sutures (V-Loc™ 180 unidirectional suture; Covidien, Mansfield, MA) and standard braided sutures (Vicryl ® ; Ethicon Inc., Somerville, MA) during vaginal cuff closure of patients undergoing a total laparoscopic hysterectomy (TLH) due to benign diseases. Eighty-nine patients were in the standard suture group and 208 patients were included in the barbed suture group. Vaginal cuff dehiscence was identified in only three (3.3%) patients within the standard suture group and none in the barbed suture group. Five (5.6%) patients in the standard suture group and two (0.9%) patients in the barbed suture group developed postoperative cuff infection/cellulitis. Duration of the surgery was significantly shorter in the barbed suture group than in the standard suture group (p barbed suture, which is used during TLH for vaginal cuff closure, is an applicable, safe and tolerable alternative to a standard suture. IMPACT STATEMENT What is already known on this subject: Barbed sutures are a relatively new type of suture that include sharp barbs inserted on monofilament material in various configurations, and are used for approximating tissues without any need for surgical knotting. They have increasingly been used in obstetrics and gynaecology in recent years, particularly in total laparoscopic hysterectomy and laparoscopic myomectomy. At present, there are a limited number of studies of V-Loc™ suture in the literature. What the results of this study add: We demonstrated that barbed sutures used for enabling vaginal cuff integrity did not cause major morbidity and mortality for the patient. We suggest that V-Loc™ 180 barbed sutures offer a practical, safe and tolerable alternative for surgeons because they are easy to use, do not cause a significant increase in vaginal cuff complications, and shorten the operating time. Our study with V-Loc™ 180 unidirectional barbed

  8. Automatic Detection of Wild-type Mouse Cranial Sutures

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Darvann, Tron Andre; Hermann, Nuno V.

    , automatic detection of the cranial sutures becomes important. We have previously built a craniofacial, wild-type mouse atlas from a set of 10 Micro CT scans using a B-spline-based nonrigid registration method by Rueckert et al. Subsequently, all volumes were registered nonrigidly to the atlas. Using......, the observer traced the sutures on each of the mouse volumes as well. The observer outperforms the automatic approach by approximately 0.1 mm. All mice have similar errors while the suture error plots reveal that suture 1 and 2 are cumbersome, both for the observer and the automatic approach. These sutures can...

  9. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  10. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Double-arm-bar Suturing System (with video).

    Science.gov (United States)

    Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu

    2014-02-01

    Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.

  11. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Devi, Dipali [Seri biotech laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Kalita, Dhaneswar [Government Ayurvedic College and Hospital, Jalukbari, Guwahati, Assam 781014 (India); Kalita, Kasturi [Department of Pathology, Hayat Hospital, Guwahati, Assam 781034 (India); Dash, Suvakanta [Girijananda Chowdhury Institute of pharmaceutical science, Azara, Guwahati, Assam 781017 (India); Kotoky, Jibon, E-mail: jkotoky@gmail.com [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India)

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  12. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    International Nuclear Information System (INIS)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-01-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  13. Achondroplasia and multiple-suture craniosynostosis.

    Science.gov (United States)

    Albino, Frank P; Wood, Benjamin C; Oluigbo, Chima O; Lee, Angela C; Oh, Albert K; Rogers, Gary F

    2015-01-01

    Genetic mutations in the fibroblast growth factor receptor 3 gene may lead to achondroplasia or syndromic forms of craniosynostosis. Despite sharing a common genetic basis, craniosynostosis has rarely been described in cases of confirmed achondroplasia. We report an infant with achondroplasia who developed progressive multiple-suture craniosynostosis to discuss the genetic link between these clinical entities and to describe the technical challenges associated with the operative management.

  14. A previously unreported variant of the synostotic sagittal suture: Case report and review of salient literature

    Directory of Open Access Journals (Sweden)

    Madison Budinich

    2016-12-01

    Full Text Available Introduction: Sagittal synostosis is a rare congenital disease caused by the premature fusion of the sagittal suture. Craniosynostosis occurs for a variety of reasons, different for every case, and often the etiology is unclear but the anomaly can frequently be seen as part of Crouzon's or Apert's syndromes. Herein, we discuss a rare case of craniosynostosis where the patient presented with a, to our knowledge, a previously undescribed variant of sagittal synostosis. Case report: A 3-month-old female infant presented to a craniofacial clinic for a consultation regarding an abnormal head shape. Images of the skull were performed, demonstrating that the patient had craniosynostosis. The patient displayed no other significant symptoms besides abnormalities in head shape. The sagittal suture was found to extend into the occipital bone where it was synostotic. Conclusion: To our knowledge, a synostotic sagittal suture has not been reported that extended posteriorly it involve the occipital bone. Those who interpret imaging or operate on this part of the skull should consider such a variation. Keywords: Anatomy, Craniosynostosis, Skull, Malformation, Pediatrics

  15. The biomechanical role of the chondrocranium and sutures in a lizard cranium.

    Science.gov (United States)

    Jones, Marc E H; Gröning, Flora; Dutel, Hugo; Sharp, Alana; Fagan, Michael J; Evans, Susan E

    2017-12-01

    The role of soft tissues in skull biomechanics remains poorly understood. Not least, the chondrocranium, the portion of the braincase which persists as cartilage with varying degrees of mineralization. It also remains commonplace to overlook the biomechanical role of sutures despite evidence that they alter strain distribution. Here, we examine the role of both the sutures and the chondrocranium in the South American tegu lizard Salvator merianae We use multi-body dynamics analysis (MDA) to provide realistic loading conditions for anterior and posterior unilateral biting and a detailed finite element model to examine strain magnitude and distribution. We find that strains within the chondrocranium are greatest during anterior biting and are primarily tensile; also that strain within the cranium is not greatly reduced by the presence of the chondrocranium unless it is given the same material properties as bone. This result contradicts previous suggestions that the anterior portion (the nasal septum) acts as a supporting structure. Inclusion of sutures to the cranium model not only increases overall strain magnitudes but also leads to a more complex distribution of tension and compression rather than that of a beam under sagittal bending. © 2017 The Authors.

  16. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  17. Subcuticular Suture Technique: Alternative to Frost Suture to Prevent Ectropion After Transcutaneous Incision of Lower Eyelid.

    Science.gov (United States)

    Kudva, Adarsh; Kamath, Abhay; Cariappa, K M; Gadicherla, Srikanth; Dhara, B Vasantha

    2017-12-01

    An ectropion is a complication that can arise from reconstruction in the infraorbital region. Often, this complication occurs despite proper positioning of the lower lid at the time of closure. Various transcutaneous approaches to orbit skeleton have investigated in view of complication arising from them. A subtarsal approach with a postoperative Frost suture gives an advantage to reduce the occurrence of ectropion especially after treatment of orbital floor fractures. This case describes a method of subcuticular suturing technique for subtarsal incision of lower lid which can be used to support the lid during healing period, thus decreasing the rate of ectropion. The technique described here is an alterative method for frost suturing with certain advantages.

  18. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  19. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  20. Bidirectional Barbed Sutures for Wound Closure: Evolution and Applications

    Science.gov (United States)

    Paul, Malcolm D.

    2009-01-01

    Traditionally, wound closure sutures have in common the need to tie knots with the inherent risk of extrusion, palpability, microinfarcts, breakage, and slippage. Bidirectional barbed sutures have barbs arrayed in a helical fashion in opposing directions on either side of an unbarbed midsegment. This suture is inserted at the midpoint of a wound and pulled through till resistance is encountered from the opposing barbs; each half of the suture is then advanced to the lateral ends of the wound. This design provides a method of evenly distributing tension along the incision line, a faster suture placement and closure time with no need to tie knots, and the possibility of improved cosmesis. Bidirectional barbed sutures, which are available in both absorbable and nonabsorbable forms, can be used for simple closures, multilayered closures, and closure of high-tension wounds in a variety of surgical settings. PMID:24527114

  1. The frontosphenoidal suture: fetal development and phenotype of its synostosis

    Energy Technology Data Exchange (ETDEWEB)

    Mathijssen, Irene M.J.; Meulen, Jacques J.N.M. van der; Adrichem, Leon N.A. van; Vaandrager, J.M.; Vermeij-Keers, Christl [Erasmus MC, University Medical Centre, Department of Plastic and Reconstructive Surgery, Rotterdam (Netherlands); Hulst, Rene R.W.J. van der [University Hospital Maastricht, Department of Plastic and Reconstructive Surgery, Maastricht (Netherlands); Lequin, Maarten H. [Erasmus MC, University Medical Centre, Department of Radiology, Rotterdam (Netherlands)

    2008-04-15

    Isolated synostosis of the frontosphenoidal suture is very rare and difficult to diagnose. Little has been reported on the clinical presentation and fetal development of this suture. To understand the development of the frontosphenoidal suture and the outcome of its synostosis. We studied the normal fetal development of the frontosphenoidal suture in dry human skulls and the clinical features of four patients with isolated synostosis of the frontosphenoidal suture. The frontosphenoidal suture develops relatively late during the second trimester of pregnancy, which explains the mild phenotype when there is synostosis. This rare craniosynostosis results in a deformity that causes recession of the lateral part of the frontal bone and supraorbital rim, with minimal facial asymmetry. Three-dimensional CT is the best examination to confirm the diagnosis. Isolated frontosphenoidal synostosis should be considered in patients with unilateral flattening of the forehead at birth that does not improve within the first few months of life. (orig.)

  2. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  3. Spondylolisthesis and Posterior Instability

    International Nuclear Information System (INIS)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D.; Simons, P.; Kuchta, J.

    2009-01-01

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI

  4. Spondylolisthesis and Posterior Instability

    Energy Technology Data Exchange (ETDEWEB)

    Niggemann, P.; Beyer, H.K.; Frey, H.; Grosskurth, D. (Privatpraxis fuer Upright MRT, Koeln (Germany)); Simons, P.; Kuchta, J. (Media Park Klinik, Koeln (Germany))

    2009-04-15

    We present the case of a patient with a spondylolisthesis of L5 on S1 due to spondylolysis at the level L5/S1. The vertebral slip was fixed and no anterior instability was found. Using functional magnetic resonance imaging (MRI) in an upright MRI scanner, posterior instability at the level of the spondylolytic defect of L5 was demonstrated. A structure, probably the hypertrophic ligament flava, arising from the spondylolytic defect was displaced toward the L5 nerve root, and a bilateral contact of the displaced structure with the L5 nerve root was shown in extension of the spine. To our knowledge, this is the first case described of posterior instability in patients with spondylolisthesis. The clinical implications of posterior instability are unknown; however, it is thought that this disorder is common and that it can only be diagnosed using upright MRI.

  5. Sutural simplification in Physodoceratinae (Aspidoceratidae, Ammonitina

    Directory of Open Access Journals (Sweden)

    Checa, A.

    1987-08-01

    Full Text Available The estructural analysis of the shell septum interrelationship in sorne Jurassic ammonites allows us to conclude that sutural simplifications occurred throughout the phylogeny, were originated by alterations in the external morphology of the shell. In the case of Physodoceratinae the simplification observed in the morphology of the septal suture may have a double origin. First, an increase in the size of periumbilical tubercles may determine a shallowing of sutural elements and a shortening of saddle and lobe frilling. In other cases, shallowing is determined by a decrease in the whorl expansion rate, an apparent shortening of secondary branching not being observed.El análisis estructural de la interrelación concha-septo en algunos ammonites del Jurásico superior lleva a concluir que las simplificaciones suturales aparecidas a lo largo de la filogenia fueron originadas por alteraciones ocurridas en la morfología externa de la concha. En el caso concreto de la subfamilia Physodoceratinae, la simplificación observada en la morfología de la sutura puede tener un doble origen. En primer lugar, un incremento en el tamaño de los tubérculos periumbilicales puede determinar una pérdida de profundidad de los elementos de la sutura. siempre acompañada de una disminución en las indentaciones (frilling de sillas y lóbulos. En otros casos el acortamiento en profundidad está determinado por una disminución de la tasa de expansión de la espira, sin que se observe un acortamiento aparente de las ramificaciones secundarias.

  6. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time-efficien......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time...

  7. Visual Measurement of Suture Strain for Robotic Surgery

    Directory of Open Access Journals (Sweden)

    John Martell

    2011-01-01

    Full Text Available Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

  8. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  9. Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius H. de Carvalho

    Full Text Available Abstract Introduction: Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective: To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods: 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results: In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002. In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002. Intraluminal adhesive penetration has not been noticed. Conclusion: There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries.

  10. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  11. COMPARISON OF ABSORBABLE EXTRA LONG TERM POLY HYDROXY BUTYRATE SUTURE VS NON ABSORBABLE (POLYPROPYLENE SUTURE FOR ABDOMINAL WALL CLOSURE

    Directory of Open Access Journals (Sweden)

    Mallikarjun

    2015-07-01

    Full Text Available PURPOSE: The aim of study is to compare Continuous technique with non - absorbable sutures, Interrupted technique with non - absorbable sutures and Continuous technique with slowly absorbable sutures Focusing mainly on incidence of incisional hernias, burst abdomen, wound infections, chronic wound pain, suture sinus, stitch granuloma, time for rectus closure. METHODOLOGY : Study was conducted for a period of one year on 271 randomized patients with primary elective midline laparotomy in our hospital . patients are divided into group I includes 102 patients with continuous technique using non absorbable polypropylene, group II includes 91 patients with interrupted technique using non absorbable polypropylene and group III includes 78 patients with continuous slowly absorbable polyhydroxybutyrate. RESULTS: No significant difference observed in incidence of wound infections and burst abdomen in all the 3 groups but relatively higher incidence of wound infections in noted our hospital. Incidence of stich granuloma suture sinus and chronic wound pain is more with interrupted technique than continuous technique and are more with non - absor bable suture material. CONCLUSION: Incidence of incisional hernias, suture complications like suture sinus, stitch granuloma can be more effectively reduced with slowly absorbable continuous sutures.

  12. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  13. Geophysical exploration of the Kalahari Suture Zone

    Science.gov (United States)

    Brett, J. S.; Mason, R.; Smith, P. H.

    2000-04-01

    Fancamp Resources Limited of Montreal, Canada, commenced exploration of the Kalahari Suture Zone in southwest Botswana in 1996, following the interpretation of airborne magnetic surveys covering 400 km of strike along the Kalahari Suture Zone. Initial focus was on mafic/ultramafic intrusions associated with the Tshane Complex as potential targets for CuNiPGM mineralization, but these targets are now considered to be too deeply buried (> 700 m) to be of economic significance at this time. The exploration focus has been redirected to several prospective large coincident magnetic/gravity anomalies. These are considered prospective targets for Olympic Dam-type CuCo mineralisation associated with alkaline intrusive complexes, and/or NiCuCoPGM mineralisation associated with basic intrusive complexes. The two most important and prospective targets are the so-called 'Great Red Spot' and Tsetseng Complex. Additional ground geophysical surveys and deep drilling are planned for the next phase of exploration. These large targets are of high priority and represent tremendous potential for mineral development in the sparsely populated area of western Botswana.

  14. Tensile strength and failure load of sutures for robotic surgery.

    Science.gov (United States)

    Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P

    2017-08-01

    Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety

  15. Characterization of craniofacial sutures using the finite element method.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Wagner, Diane; Whyne, Cari M

    2014-01-03

    Characterizing the biomechanical behavior of sutures in the human craniofacial skeleton (CFS) is essential to understand the global impact of these articulations on load transmission, but is challenging due to the complexity of their interdigitated morphology, the multidirectional loading they are exposed to and the lack of well-defined suture material properties. This study aimed to quantify the impact of morphological features, direction of loading and suture material properties on the mechanical behavior of sutures and surrounding bone in the CFS. Thirty-six idealized finite element (FE) models were developed. One additional specimen-specific FE model was developed based on the morphology obtained from a µCT scan to represent the morphological complexity inherent in CFS sutures. Outcome variables of strain energy (SE) and von Mises stress (σvm) were evaluated to characterize the sutures' biomechanical behavior. Loading direction was found to impact the relationship between SE and interdigitation index and yielded varied patterns of σvm in both the suture and surrounding bone. Adding bone connectivity reduced suture strain energy and altered the σvm distribution. Incorporating transversely isotropic material properties was found to reduce SE, but had little impact on stress patterns. High-resolution µCT scanning of the suture revealed a complex morphology with areas of high and low interdigitations. The specimen specific suture model results were reflective of SE absorption and σvm distribution patterns consistent with the simplified FE results. Suture mechanical behavior is impacted by morphologic factors (interdigitation and connectivity), which may be optimized for regional loading within the CFS. © 2013 Elsevier Ltd. All rights reserved.

  16. Posterior microphthalmos pigmentary retinopathy syndrome.

    Science.gov (United States)

    Pehere, Niranjan; Jalali, Subhadra; Deshmukh, Himanshu; Kannabiran, Chitra

    2011-04-01

    Posterior Microphthalmos Pigmentary Retinopathy Syndrome (PMPRS). Posterior microphthalmos (PM) is a relatively infrequent type of microphthalmos where posterior segment is predominantly affected with normal anterior segment measurements. Herein, we report two siblings with posterior microphthalmos retinopathy syndrome with postulated autosomal recessive mode of inheritance. A 13-year-old child had PM and retinitis pigmentosa (RP) and his 7-year-old sister had PM, RP, and foveoschisis. The genetics of this syndrome and variable phenotype is discussed. Importance of being aware of posterior microphthalmos and its posterior segment associations is highlighted.

  17. Bridge Suture for Successful McDonald Emergency Cerclage.

    Science.gov (United States)

    Tanaka, Masaaki; Hori, Yoshiaki; Shirafuji, Aya; Kato, Mitsunori; Kato, Jyun; Kobayashi, Hiroto; Tsuchida, Toru; Fukae, Tsukasa

    2017-01-01

    To create awareness about a surgical technique termed bridge suture, which is performed as a pretreatment before a McDonald cerclage is performed on an emergency to treat severe cervical insufficiency. Procedures for bridge suture were reviewed in detail and outcomes of 16 patients treated with bridge suture followed by McDonald cerclage were evaluated retrospectively. Using the bridge suture, the edges of uterine cervix were temporarily sutured and the external uterine os was closed, while the hourglass-shaped fetal membranes were concomitantly confined within the cervix; subsequently, a McDonald cerclage was performed. Over a 22-year period, 16 patients with a dilated cervix and bulging fetal membranes were treated using the technique of bridge suture followed by an emergency cerclage. The mean gestational age at cerclage was 22.5 weeks; the mean gestational age at delivery was 30.7 weeks; and the mean interval between cerclage and delivery was 8.2 weeks. In 15 out of 16 cases, cerclage was performed without encountering any complications. No maternal complications, including cervical laceration, were observed. The mean body weight of 17 neonates, including that of a twin, was 1,516 g and of them, 15 neonates survived. The important outcome of bridge suture is the replacement of fetal membranes back into the uterine cavity before McDonald's cerclage is performed. Pretreatment with bridge suture may facilitate the performance of a successful emergency cerclage and contribute to good maternal and neonatal outcomes. © 2016 S. Karger AG, Basel.

  18. Arthroscopic Hip Labral Repair: The Iberian Suture Technique

    OpenAIRE

    Stubbs, Allston J.; Andersen, Jason S.; Mannava, Sandeep; Wooster, Benjamin M.; Howse, Elizabeth A.; Winter, S. Bradley

    2014-01-01

    Arthroscopic hip labral repair has beneficial short-term outcomes; however, debate exists regarding ideal surgical labral repair technique. This technical note presents an arthroscopic repair technique that uses intrasubstance labral suture passage to restore the chondrolabral interface. This “Iberian suture technique” allows for an anatomic repair while posing minimal risk of damage to the labral and chondral tissues.

  19. Robot-assisted bronchoplasty using continuous barbed sutures.

    Science.gov (United States)

    Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc

    2018-01-01

    We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.

  20. Mechanical model of suture joints with fibrous connective layer

    Science.gov (United States)

    Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning

    2018-02-01

    A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.

  1. Suture associated corneal abscess three years after cataract surgery ...

    African Journals Online (AJOL)

    The abscess was carefully removed on slit lamp using blunt tipped forceps without breaking the thin membrane covering it. There was a deep corneal depression at the bottom of which was found a loose 10/0 nylon corneoscleral suture. Another loose suture was present at the 12 o'clock position surrounded by stromal ...

  2. [Cystourethroanastomosis in extended obliterations and strictures of the posterior urethra in men].

    Science.gov (United States)

    Mitusov, V V; Aboian, I A

    2005-01-01

    The authors review short- and long-term clinical results of surgical treatment of extended urethral strictures and obliterations. A new vesicourethral anastomosis was created by novel technique with longitudinal suturing of the neck of the urinary bladder. A scheme of the operation is presented. Causes necessitating this plastic intervention are analysed. Variants of possible urine incontinence after operation depending on etiological cause of the stricture or obliteration of the posterior urethra in males are considered.

  3. Posterior Reversible Encephalopathy (PRES)

    International Nuclear Information System (INIS)

    Moron E, Fanny E; Diaz Marchan, Pedro

    2005-01-01

    The Posterior Reversible Encephalopathy Syndrome (PRES) is a clinical Syndrome composed of cephalea, alteration in vision and convulsions, usually observed in patients with sudden elevation of arterial pressure. The imagenologic evidence shows reversible vasogenic brain edema without stroke. Its location is predominantly posterior; it affects the cortex and the subcortical white matter of the occipital, parietal and temporal lobes. The treatment with antihypertensive drugs and the removing of immunosupressor medication are generally associated with complete neurological recovery; this is reflected also in the images which return to their basal condition. The untreated hypertension, on the other side, can result in a progressive defect of the autoregulation system of the central nervous system with cerebral hemorrhage, irreversible brain stroke, coma and death

  4. Robotic posterior retroperitoneal adrenalectomy.

    Science.gov (United States)

    Okoh, Alexis Kofi; Yigitbas, Hakan; Berber, Eren

    2015-09-01

    Since its initial description by Mercan et al. laparoscopic posterior retroperitoneal (PR) adrenalectomy has served as an alternaltive to the transabdominal (TL) approach for the treatment of adrenal pathologies. Robotic adrenal surgery has been reported to improve surgeon ergonomics and facilitate dissection. In patients with bilateral adrenal masses, PR adrenalectomy may be the approach of choice. We herein describe the technique, discuss its limitations and present a critical review of the current literature. © 2015 Wiley Periodicals, Inc.

  5. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve.

    Science.gov (United States)

    Khan, Jaffar M; Rogers, Toby; Schenke, William H; Greenbaum, Adam B; Babaliaros, Vasilis C; Paone, Gaetano; Ramasawmy, Rajiv; Chen, Marcus Y; Herzka, Daniel A; Lederman, Robert J

    2018-02-06

    Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm 2 to 3.8 ± 1.5 cm 2 (naïve) and 13.1 ± 1.5 cm 2 to 6.2 ± 1.0 cm 2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P PASTA reduces annular dimensions and tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  6. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  7. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  8. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  9. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  10. Gas microstrip chambers

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  11. A new surgical technique for traumatic dislocation of posterior tibial tendon with avulsion fracture of medial malleolus.

    Science.gov (United States)

    Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol

    2015-01-01

    We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.

  12. Complications with mechanical suture use in colorectal surgery

    International Nuclear Information System (INIS)

    Bruno, G.; Ruso, L.; Gatti, A.; Quiros, F.; Balboa, O.

    1998-01-01

    The great development of mechanical suture and its qualitative impact in colorectal surgery has not been able to avoid persistent mortality due to suture failure which is still about 5% and rectal stenosis, which is significantly higher than with manual sutures.The present paper analyses 63 cases of colorrectal anastomosis performed of coordination with mechanical suture at CASMU, in a period of four years (1991-1995).There were 51 rectum resections and colorrectal anastomosis and 12 reconstruction of intestinal transit.There were 28 females and 35 males with and average age of 66 years.Three patients died (4,7%), 20 (31,7%) suffered various complications among which some are pointed out in relation to mechanical suture to suture failures(3,1%) who died and 8 rectal stenosis(12,9%)with favourable evolution after dilations.The authors analyse the issues that incide on the production of complications in colorrectal surgery and conclude that the incidence of global complications in their series is elevated, although mortality, suture failure and rectal stenosis figures are comparable to those in international literature analysed.The incidence of machine width proximal ostomies and radiotherapy on the development of stenosis in our milieu require a multicentric studie with a greater number of patients

  13. Reversible posterior leukoencephalopathy syndrome

    International Nuclear Information System (INIS)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won; Song, Chang Joon; Song, Soon-Young; Koo, Ja Hong; Kim, Man Deuk

    2001-01-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  14. Reversible posterior leukoencephalopathy syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ja; Yu, Won Jong; Ahn, Kook Jin; Jung, So Lyung; Lee, Yeon Soo; Kim, Ji Chang; Kang, Si Won [The Catholic Univ. of Korea, Taejon (Korea, Republic of); Song, Chang Joon [Chungnam National Univ. School of Medicine, Cheonju (Korea, Republic of); Song, Soon-Young; Koo, Ja Hong [Kwandong Univ. College of Medicine, Myungji Hospital, Seoul (Korea, Republic of); Kim, Man Deuk [College of Medicine Pochon CHA Univ., Seoul (Korea, Republic of)

    2001-10-01

    To review reversible posterior leukoencephalopathy syndrome. We reviewed 22 patients (M:F=3:19; age, 17-46 years) with the characteristic clinical and imaging features of reversible posterior leukoencephalopathy syndrome. All underwent brain MRI, and in three cases both CT and MRI were performed. In one, MRA was obtained, and in eleven, follow-up MR images were obtained. We evaluated the causes of this syndrome, its clinical manifestations, and MR findings including the locations of lesions, the presence or absence of contrast enhancement, and the changes seen at follow-up MRI. Of the 22 patients, 13 had eclampsia (six during pregnancy and seven during puerperium). Four were receiving immunosuppressive therapy (three, cyclosporine ; one, FK 506). Four suffered renal failure and one had complicated migraine. The clinical manifestations included headache (n=12), visual disturbance (n=13), seizure (n=15), focal neurologic sign (n=3), and altered mental status (n=2). Fifteen patients had hypertension and the others normotension. MRI revealed that lesions were bilateral (n=20) or unilateral (n=2). In all patients the lesion was found in the cortical and subcortical areas of the parieto-occipital lobes ; other locations were the basal ganglia (n=9), posterior temporal lobe (n=8), frontal lobe (n=5), cerebellum (n=5), pons (n=2), and thalamus (n=1). All lesions were of high signal intensity on T2-weighted images, and of iso to low intensity on T1-weighted images. One was combined with acute hematoma in the left basal ganglia. In eight of 11 patients who underwent postcontrast T1-weighted MRI, there was no definite enhancement ; in one, enhancement was mild, and in tow, patchy. CT studies showed low attenuation, and MRA revealed mild vasospasm. The symptoms of all patients improved. Follow-up MRI in nine of 11 patients depicted complete resolution of the lesions ; in two, small infarctions remained but the extent of the lesions had decreased. Reversible posterior

  15. Posterior Urethral Strictures

    Directory of Open Access Journals (Sweden)

    Joel Gelman

    2015-01-01

    Full Text Available Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty.

  16. Posterior Urethral Strictures

    Science.gov (United States)

    Gelman, Joel; Wisenbaugh, Eric S.

    2015-01-01

    Pelvic fracture urethral injuries are typically partial and more often complete disruptions of the most proximal bulbar and distal membranous urethra. Emergency management includes suprapubic tube placement. Subsequent primary realignment to place a urethral catheter remains a controversial topic, but what is not controversial is that when there is the development of a stricture (which is usually obliterative with a distraction defect) after suprapubic tube placement or urethral catheter removal, the standard of care is delayed urethral reconstruction with excision and primary anastomosis. This paper reviews the management of patients who suffer pelvic fracture urethral injuries and the techniques of preoperative urethral imaging and subsequent posterior urethroplasty. PMID:26691883

  17. An electrodeless drift chamber

    International Nuclear Information System (INIS)

    Allison, J.; Barlow, R.J.; Bowdery, C.K.; Duerdoth, I.; Rowe, P.G.

    1982-01-01

    We describe a chamber in which the drift field is controlled by the deposition of electrostatic charge on an insulating surface. The chamber operates with good efficiency and precision for observed drift distances of up to 45 cm, promises to be extremely robust and adaptable and offers a very cheap way of making particle detectors. (orig.)

  18. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  19. Plastic flashtube chambers

    International Nuclear Information System (INIS)

    Frisken, W.R.

    1977-01-01

    A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber

  20. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  1. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  2. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  3. DELPHI time projection chamber

    CERN Multimedia

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  4. Bacterial adhesion to suture material in a contaminated wound model: Comparison of monofilament, braided, and barbed sutures.

    Science.gov (United States)

    Dhom, Jonas; Bloes, Dominik A; Peschel, Andreas; Hofmann, Ulf K

    2017-04-01

    Contaminated suture material plays an important role in the physiopathology of surgical site infections. Recently, suture material has been developed characterized by barbs projecting from a monofilament base. Claimed advantages for barbed sutures are a shortened wound closure time and reduced maximum wound tension. It has also been suggested that these sutures would be advantageous microbiologically. The aim of this study was to test the microbiological characteristics of the barbed Quill in comparison to the monofilament Ethilon II and the braided sutures Vicryl and triclosan-coated Vicryl Plus. In our study, sutures were cultivated on color-change agar with Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, Escherichia coli, and Pseudomonas aeruginosa and the halo size was measured. In a second study arm with longer cultivation bacterial growth was followed by antibiotic treatment. Ethilon II and Quill showed good comparable results, whereas large halos were found around Vicryl. Vicryl Plus results depended on triclosan sensitivity. After longer bacterial cultivation and antibiotic treatment, halos were up to 3.6 times smaller on Quill than on Vicryl (p barbs on Quill. From a microbiological perspective, barbed sutures can be recommended in aseptic surgery, but should only be used carefully in septic surgery. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:925-933, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. MonoMax Suture: A New Long-Term Absorbable Monofilament Suture Made from Poly-4-Hydroxybutyrate

    Directory of Open Access Journals (Sweden)

    Erich K. Odermatt

    2012-01-01

    Full Text Available A long-term absorbable monofilament suture was developed using poly-4-hydroxybutyrate (P4HB made from a biosynthetically produced homopolymer of the natural metabolite 4-hydroxybutyrate. The suture, called MonoMax, has prolonged strength retention. At 12 weeks, a size 3-0 MonoMax suture retains approximately 50% of its initial tensile strength in vivo and is substantially degraded in one year with minimal tissue reaction. In contrast, PDS II monofilament suture (Ethicon, Inc., Somerville, NJ has no residual strength in vivo after 12 weeks. In vivo, the MonoMax suture is hydrolyzed primarily by bulk hydrolysis, and is then degraded via the Krebs cycle. MonoMax is substantially more compliant than other monofilament sutures, and incorporates an element of elasticity. Its tensile modulus of 0.48 GPa is approximately one-third of the value of the PDS II fiber providing an exceptionally flexible and pliable fiber with excellent knot strength and security. These features are further enhanced by the fiber's elasticity, which also improves knot security and may help prevent wound dehiscence. Because of its performance advantages, this suture may find clinical utility in applications where prolonged strength retention, and greater flexibility are required, particularly in procedures like abdominal wall closure where wound dehiscence is still a significant post-surgical complication.

  6. Posterior glenoid rim deficiency in recurrent (atraumatic) posterior shoulder instability

    International Nuclear Information System (INIS)

    Weishaupt, D.; Zanetti, M.; Hodler, J.; Nyffeler, R.W.; Gerber, C.

    2000-01-01

    Objective. To assess the shape of the posterior glenoid rim in patients with recurrent (atraumatic) posterior instability.Design and patients. CT examinations of 15 shoulders with recurrent (atraumatic) posterior instability were reviewed in masked fashion with regard to abnormalities of the glenoid shape, specifically of its posterior rim. The glenoid version was also assessed. The findings were compared with the findings in 15 shoulders with recurrent anterior shoulder instability and 15 shoulders without instability. For all patients, surgical correlation was available.Results. Fourteen of the 15 (93%) shoulders with recurrent (atraumatic) posterior shoulder instability had a deficiency of the posteroinferior glenoid rim. In patients with recurrent anterior instability or stable shoulders such deficiencies were less common (60% and 73%, respectively). The craniocaudal length of the deficiencies was largest in patients with posterior instability. When a posteroinferior deficiency with a craniocaudal length of 12 mm or more was defined as abnormal, sensitivity and specificity for diagnosing recurrent (atraumatic) posterior instability were 86.7% and 83.3%, respectively. There was a statistically significant difference in glenoid version between shoulders with posterior instability and stable shoulders (P=0.01).Conclusion. Recurrent (atraumatic) posterior shoulder instability should be considered in patients with a bony deficiency of the posteroinferior glenoid rim with a craniocaudal length of more than 12 mm. (orig.)

  7. Isolated posterior capsular rupture following blunt head trauma

    Directory of Open Access Journals (Sweden)

    Mansour AM

    2014-11-01

    Full Text Available Ahmad M Mansour, Mahmoud O Jaroudi, Rola N Hamam, Fadi C Maalouf Department of Ophthalmology, American University of Beirut, Beirut, Lebanon Abstract: Closed-globe traumatic cataract is not uncommon in males in the pediatric age group. However, there is a relative paucity of literature on isolated posterior lens capsule rupture associated with closed-globe traumatic cataract. We report a case of a 6-year-old boy who presented with white cataract 1 day after blunt trauma to the forehead associated with posterior capsular rupture that was detected by B-scan ultrasonography preoperatively. No stigmata of trauma outside the posterior capsule could be detected by slit-lamp exam, funduscopy, and optical coherence tomography. Phacoemulsification with posterior chamber intraocular lens implant was performed 24 hours after trauma, with the patient achieving 6/6 visual acuity 1 week and 6 months after surgery. Our case is unique, being the youngest (amblyogenic age to be reported, with prompt surgical intervention, and with no signs of trauma outside the posterior capsule. Keywords: posterior capsule rupture, forehead trauma, traumatic cataract, pediatric cataract

  8. Outcome of Strabismus Surgery by Nonadjustable Suture among ...

    African Journals Online (AJOL)

    2017-03-06

    years old with strabismus seen ... adult with nonadjustable suture is safe and effective procedure with low risk of ... Strabismus or misalignment of the eyes is a condition that ... with Log MAR, type of refractive error, auto-refraction,.

  9. Outcome of strabismus surgery by nonadjustable suture among ...

    African Journals Online (AJOL)

    Outcome of strabismus surgery by nonadjustable suture among adults attending a ... postoperative residual deviation, 83 patients (86%) had defective vision with amblyopia. ... Conclusion: Surgical treatment of strabismus in Saudi adult with ...

  10. Irreducible Traumatic Posterior Shoulder Dislocation

    Directory of Open Access Journals (Sweden)

    Blake Collier

    2017-01-01

    Full Text Available History of present illness: A 22-year-old male presented to the Emergency Department complaining of right shoulder pain after a motocross accident. He was traveling at approximately 10 mph around a turn when he lost control and was thrown over the handlebars, landing directly on his right shoulder. On arrival, he was holding his arm in adduction and internal rotation. An area of swelling was noted over his anterior shoulder. He was unable to abduct his shoulder. No humeral gapping was noted. He had normal neuro-vascular status distal to the injury. Significant findings: Radiographs demonstrated posterior displacement of the humeral head on the “Y” view (see white arrow and widening of the glenohumeral joint space on anterior-posterior view (see red arrow. The findings were consistent with posterior dislocation and a Hill-Sachs type deformity. Sedation was performed and reduction was attempted using external rotation, traction counter-traction. An immediate “pop” was felt during the procedure. Post-procedure radiographs revealed a persistent posterior subluxation with interlocking at posterior glenoid. CT revealed posterior dislocation with acute depressed impaction deformity medial to the biceps groove with the humeral head perched on the posterior glenoid, interlocked at reverse Hill-Sachs deformity (see blue arrow. Discussion: Posterior shoulder dislocations are rare and represent only 2% of all shoulder dislocations. Posterior shoulder dislocations are missed on initial diagnosis in more than 60% of cases.1 Posterior shoulder dislocations result from axial loading of the adducted and internally rotated shoulder, violent muscle contractions (resulting from seizures or electrocution, a direct posterior force applied to the anterior shoulder.1 Physical findings include decreased anterior prominence of the humeral head, increased palpable posterior prominence of the humeral head below the acromion, increased palpable prominence of the

  11. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  12. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Integral Suture-Handling Techniques for Arthroscopic Sliding Knots

    OpenAIRE

    Kanchanatawan, Wichan; Kongtharvonskul, Jatupon; Dorjiee, Gem; Suppauksorn, Sunikom; Pornvoranunt, Umpire; Karchana, Pongsakorn

    2016-01-01

    In arthroscopic tissue repair, the final step is achieving adequate tissue approximation with a secure knot. The sliding knot is widely preferred over the nonsliding knot, with numerous publications describing knot configurations. However, in the literature there are few published descriptions of suture-handling techniques, even though they are fundamental to arthroscopic knot tying. We describe integral suture-handling techniques for arthroscopic sliding knots to improve the surgeon's perfor...

  14. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    Directory of Open Access Journals (Sweden)

    Swati R Yedke

    2013-01-01

    Full Text Available Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3 rd and 7 th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries.

  15. SUTURE NON-SUTSRE CIRCUMFERENTIAL REPAIR OF CAROTID ARTERY

    Directory of Open Access Journals (Sweden)

    Jafar Nader

    1969-01-01

    Full Text Available plastic adhesives, normal butyl cyanoacrylate monomer, isobutyl cyanoacrylate monomer and methyl 2 _ cyaooacrylate monomer, have been utilized in a comparative study with 5-{ silk suture in the repair of transected carotid arteries. Follow _ up arteriog ramS indicate isobutyl cyanoacrylate monomer and normal butyl cyanoacrylate monomer as having the most impressive rerults with only tWO thrombosis each. The silk suture had three thromboses and the adhesive methyl 2 _ cyanoacrylate monomer had nine, one of which a delayed

  16. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  17. The Efficacy of Polydioxanone Monofilament Absorbable Suture for Tracheal Anastomosis

    OpenAIRE

    Kawahara, Katsunobu; Yamasaki, Naoya; Yamamoto, Satoshi; Nagayasu, Takeshi; Kusano, Hiroyuki; Akamine, Shinji; Takahashi, Takao; Tomita, Masao

    1994-01-01

    To evaluate the efficacy of polydioxanon absorbable suture for tracheal anastomoses, we performed an experimental study using dose. Eight adult mongrel dogs underwent sleeve resection of the mediastinal trachea. A length of ten to twelve cartilage rings was resected. An end-to-end anastomosis was performed using either interrupted or continuous running 4-0 polydioxanone (PDS) suture. There was no detectable difference bronchoscopically, microangiografically, or histologically, in tracheal ana...

  18. Progressive posterior cortical dysfunction

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    Full Text Available Abstract Progressive posterior cortical dysfunction (PPCD is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal and ventral (occipito-temporal pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction, complete Balint's syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right . Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD.

  19. Progressive posterior cortical dysfunction

    Science.gov (United States)

    Porto, Fábio Henrique de Gobbi; Machado, Gislaine Cristina Lopes; Morillo, Lilian Schafirovits; Brucki, Sonia Maria Dozzi

    2010-01-01

    Progressive posterior cortical dysfunction (PPCD) is an insidious syndrome characterized by prominent disorders of higher visual processing. It affects both dorsal (occipito-parietal) and ventral (occipito-temporal) pathways, disturbing visuospatial processing and visual recognition, respectively. We report a case of a 67-year-old woman presenting with progressive impairment of visual functions. Neurologic examination showed agraphia, alexia, hemispatial neglect (left side visual extinction), complete Balint’s syndrome and visual agnosia. Magnetic resonance imaging showed circumscribed atrophy involving the bilateral parieto-occipital regions, slightly more predominant to the right. Our aim was to describe a case of this syndrome, to present a video showing the main abnormalities, and to discuss this unusual presentation of dementia. We believe this article can contribute by improving the recognition of PPCD. PMID:29213665

  20. A comparison of lateral ankle ligament suture anchor strength.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Crates, John M

    2013-06-01

    Lateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction. In porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10N and 60N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded. PushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (panchors completing 200 cycles was 86.5N (PushLock) and 252.1N (Morphix) (panchor breaking and suture breakage. The knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  1. Endoscopic Management of Posterior Epistaxis

    OpenAIRE

    Paul, J.; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-01-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26–50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of ...

  2. Inlay buccal mucosal graft for reoperative posterior urethroplasty

    Directory of Open Access Journals (Sweden)

    Shou-Hung Tang

    2012-04-01

    Full Text Available Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007–2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o’clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12–15 ml/seconds in all cases for a follow-up period of 18–30 months. The recurrence rate was 50% (2/4. Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases.

  3. Inlay buccal mucosal graft for reoperative posterior urethroplasty.

    Science.gov (United States)

    Tang, Shou-Hung; Kao, Chien-Chang; Wu, Seng-Tang; Meng, En; Cha, Tai-Lung

    2012-04-01

    Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007-2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o'clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12-15 ml/seconds in all cases for a follow-up period of 18-30 months. The recurrence rate was 50% (2/4). Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases. Copyright © 2012. Published by Elsevier B.V.

  4. Acoustic-Levitation Chamber

    Science.gov (United States)

    Barmatz, M. B.; Granett, D.; Lee, M. C.

    1984-01-01

    Uncontaminated environments for highly-pure material processing provided within completely sealed levitation chamber that suspends particles by acoustic excitation. Technique ideally suited for material processing in low gravity environment of space.

  5. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  6. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  7. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  8. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  9. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  10. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  11. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  12. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  13. A combination of subcuticular suture and sterile Micropore tape compared with conventional interrupted sutures for skin closure. A controlled trial.

    Science.gov (United States)

    Taube, M.; Porter, R. J.; Lord, P. H.

    1983-01-01

    We have conducted a controlled trial to compare skin closure using conventional interrupted sutures with a combination of subcuticular suture and sterile Micropore tape in 169 patients undergoing appendicectomy, inguinal herniorrhaphy, or saphenofemoral ligation. We have found that the combination technique consistently gives a better cosmetic result and that the tape acts well as a dressing, is convenient, and is well tolerated by patients. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6344732

  14. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  15. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material

    OpenAIRE

    Baums, M. H.; Buchhorn, G. H.; Spahn, G.; Poppendieck, B.; Schultz, W.; Klinger, H.-M.

    2008-01-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-...

  16. Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study.

    Directory of Open Access Journals (Sweden)

    Jia-Lin Wu

    Full Text Available Transtibial pullout suture (TPS repair of posterior medial meniscus root (PMMR tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG and conventional TPS repair. Twelve porcine tibiae (n = 6 each TG group: flexor digitorum profundus tendon was passed through an incision in the root area, created 5 mm postero-medially along the edge of the attachment area. TPS group: a modified Mason-Allen suture was created using no. 2 FiberWire. The tendon grafts and sutures were threaded through the bone tunnel and then fixed to the anterolateral cortex of the tibia. The two groups underwent cyclic loading followed by a load-to-failure test. Displacements of the constructs after 100, 500, and 1000 loading cycles, and the maximum load, stiffness, and elongation at failure were recorded. The TG technique had significantly lower elongation and higher stiffness compared with the TPS. The maximum load of the TG group was significantly lower than that of the TPS group. Failure modes for all specimens were caused by the suture or graft cutting through the meniscus. Lesser elongation and higher stiffness of the constructs in TG technique over those in the standard TPS technique might be beneficial for postoperative biological healing between the meniscus and tibial plateau. However, a slower rehabilitation program might be necessary due to its relatively lower maximum failure load.

  17. Bilateral Posterior Tibial Tendon and Flexor Digitorum Longus Dislocations.

    Science.gov (United States)

    Padegimas, Eric M; Beck, David M; Pedowitz, David I

    2017-04-01

    The authors present a case of a previously healthy and athletic 17-year-old female who presented with a 3.5-year history of medial left ankle pain after sustaining an inversion injury while playing basketball. Prior to presentation, she had failed prior immobilization and physical therapy for a presumed ankles sprain. Physical examination revealed a dislocated posterior tibial tendon (PTT) that was temporarily reducible, but would spontaneously dislocate immediately after reduction. She had pain and snapping of the PTT with resisted ankle plantar flexion and resisted inversion as well as 4/5 strength in ankle inversion. The diagnosis of dislocated PTT was confirmed on magnetic resonance imaging (MRI). The patient underwent suture anchor repair of the medial retinaculum of the left ankle. At the time of surgery both the PTT and flexor digitorum longus (FDL) were dislocated. Three months postoperatively, the patient represented with PTT dislocation of the right (nonoperative) ankle confirmed by MRI. After failure of immobilization, physical therapy, and oral anti-inflammatory medications, the patient underwent suture anchor repair of the medial retinaculum of the right ankle. At 6 months postoperatively, the patient has 5/5 strength inversion bilaterally, no subluxation of either PTT, and has returned to all activities without limitation. The authors present this unique case of bilateral PTT dislocation and concurrent PTT/FDL dislocation along with review of the literature for PTT dislocation. The authors highlight the common misdaiganosis of this injury and highlight the successful results of surgical intervention. Level V: Case report.

  18. Mixing processes in the vitreous chamber induced by eye rotations

    Energy Technology Data Exchange (ETDEWEB)

    Stocchino, Alessandro [Department of Civil, Environmental and Architectural Engineering, University of Genoa (Italy); Repetto, Rodolfo [Department of Engineering of Structures, Water and Soil, University of L' Aquila (Italy); Siggers, Jennifer H [Department of Bioengineering, Imperial College London, London SW7 2AZ (United Kingdom)], E-mail: jorma@diam.unige.it

    2010-01-21

    In this paper, we study a model of flow in the vitreous humour in the posterior chamber of the human eye, induced by saccadic eye rotations. We concentrate on the effect of the shape of the chamber upon the mixing properties of the induced flows. We make particle image velocimetry measurements of the fluid velocity in a transparent plastic (Perspex) model of the posterior chamber during sinusoidal torsional oscillations about a vertical axis. We use a Newtonian fluid to model the vitreous humour, which is most realistic when either the vitreous humour is liquefied or has been replaced by purely viscous tamponade fluids. The model of the posterior chamber is a sphere with an indentation, representing the effect of the lens. In spite of the purely periodic forcing, a steady streaming flow is generated, which plays a fundamental role in the mixing processes in the domain. The streaming flow differs markedly from that in a perfect sphere, and its topological characteristics change substantially as the frequency of oscillation varies. We discuss the flow characteristics in detail and show that, for physiological parameter values, the Peclet number (based on a suitable measure of the steady streaming velocity) is large, suggesting that advection strongly dominates over diffusion for mass transport phenomena. We also compute particle trajectories based on the streaming velocity and use these to investigate the stirring properties of the flow.

  19. Mixing processes in the vitreous chamber induced by eye rotations

    International Nuclear Information System (INIS)

    Stocchino, Alessandro; Repetto, Rodolfo; Siggers, Jennifer H

    2010-01-01

    In this paper, we study a model of flow in the vitreous humour in the posterior chamber of the human eye, induced by saccadic eye rotations. We concentrate on the effect of the shape of the chamber upon the mixing properties of the induced flows. We make particle image velocimetry measurements of the fluid velocity in a transparent plastic (Perspex) model of the posterior chamber during sinusoidal torsional oscillations about a vertical axis. We use a Newtonian fluid to model the vitreous humour, which is most realistic when either the vitreous humour is liquefied or has been replaced by purely viscous tamponade fluids. The model of the posterior chamber is a sphere with an indentation, representing the effect of the lens. In spite of the purely periodic forcing, a steady streaming flow is generated, which plays a fundamental role in the mixing processes in the domain. The streaming flow differs markedly from that in a perfect sphere, and its topological characteristics change substantially as the frequency of oscillation varies. We discuss the flow characteristics in detail and show that, for physiological parameter values, the Peclet number (based on a suitable measure of the steady streaming velocity) is large, suggesting that advection strongly dominates over diffusion for mass transport phenomena. We also compute particle trajectories based on the streaming velocity and use these to investigate the stirring properties of the flow.

  20. [Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].

    Science.gov (United States)

    Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong

    2011-06-01

    For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.

  1. Tensile strength of the pullout repair technique for the medial meniscus posterior root tear: a porcine study.

    Science.gov (United States)

    Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-10-01

    The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.

  2. Effects of UV-B radiation on a hereditary suture cataract in mice

    International Nuclear Information System (INIS)

    Forker, Carina; Wegener, Alfred

    1997-01-01

    UV-B (290-320 nm, λ max = 305 nm) radiation and the Cat2 ns (suture cataract) mutation in mice affect both the anterior lens epithelium and the formation of the suture. A low dose of UV-B radiation (2.2 Jcm -2 ) induces similar anterior subcapsular and cortical lens opacities in wild type as in heterozygous mutant mice. The UV-B treatment of the mutant lenses, however, leads to an increase in the number of epithelial cell layers in the anterior central part as compared to the wild type indicating a more severe form of the cataract formation in mutants. In addition, mutants demonstrate a predisposition for a rupture of the posterior lens capsule, because from 2.9 Jcm -2 and higher, this phenomenon could always be observed in the UV-B treated mutants, but never in the treated wild type mice. The protein biochemical analyses were performed by gel electrophoresis and isoelectric focusing of extracts of total lenses or from defined areas of the lens (lens slice technique). These covered the patterns of those proteins already synthesized before irradiation, which in irradiated lenses in no case evidenced a difference to the untreated control, neither in the wild type nor in the mutants. In contrast, by analysing specifically those proteins, which are synthesized after irradiation, in both treated groups a protein with a molecular mass of about 31 kDa becomes discernable in both treated groups. In addition, the cataractous lenses demonstrate a significantly enhanced overall synthesis of water-soluble proteins after irradiation, which might promote the rupture of the posterior capsule at the posterior pole. The present study offers for the first time the possibility to discriminate between endogeneous (genetic) effects and exogeneous (environmental) effects in cataractogenesis and to study their interactive effects. The first set of experiments demonstrated a clear intensification of the hereditary cataract by the UV-B treatment. The study supports the hypothesis that

  3. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  4. Local Delivery of Growth Factors Using Coated Suture Material

    Directory of Open Access Journals (Sweden)

    T. F. Fuchs

    2012-01-01

    Full Text Available The optimization of healing processes in a wide range of tissues represents a central point for surgical research. One approach is to stimulate healing processes with growth factors. These substances have a short half-life and therefore it seems useful to administer these substances locally rather than systemically. One possible method of local delivery is to incorporate growth factors into a bioabsorbable poly (D, L-lactide suspension (PDLLA and coat suture material. The aim of the present study was to establish a procedure for the local delivery of growth factors using coated suture material. Sutures coated with growth factors were tested in an animal model. Anastomoses of the colon were created in a rat model using monofilament sutures. These were either untreated or coated with PDLLA coating alone or coated with PDLLA incorporating insulin—like growth factor-I (IGF-I. The anastomoses were subjected to biomechanical, histological, and immunohistochemical examination. After 3 days the treated groups showed a significantly greater capacity to withstand biomechanical stress than the control groups. This finding was supported by the results of the histomorphometric. The results of the study indicate that it is possible to deliver bioactive growth factors locally using PDLLA coated suture material. Healing processes can thus be stimulated locally without subjecting the whole organism to potentially damaging high systemic doses.

  5. Selective laser vaporization of polypropylene sutures and mesh

    Science.gov (United States)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  6. EFFECTS OF DIFFERENT SUTURE MATERIALS ON TISSUE HEALING

    Directory of Open Access Journals (Sweden)

    Fırat SELVİ

    2016-01-01

    Full Text Available Purpose: The purpose of this study was to investigate the healing differences in between four different widely used suture materials in the oral surgery practice, including silk (Perma- Hand; Ethicon, INC., Somerville, NJ, USA, polypropylene (Prolene; Ethicon, INC., Somerville, NJ, USA, coated polyglactin 910 (Ethicon, INC., Somerville, NJ, USA. and polyglecaprone 25 (Ethicon, INC., Somerville, NJ, USA . Materials and Methods: 20 male rats were randomly allocated into two groups depending on their sacrification days (post-operative 1st and the 7th days. Four longitudinal incision wounds, each 1cm in size, were created on the dorsum of each animal which were then primarily closed with four different types of sutures. Results: The effects of these suture materials on soft tissue healing were compared histopathologically, by means of density of the cells, necrosis, fibrosis, foreign body reaction, the presence of cells of acute and chronic infection. No statistically significant difference was observed between the groups regarding the density of the cells, necrosis, fibrosis, foreign body reaction, and the presence of the cells of acute & chronic infections. Of note, propylene showed slightly less tissue reaction among the other materials. Conclusion: The results of our study showed that there is no only one ideal suture material for surgical practice. The factors related to the patient, the type of the surgery and the quality of the tissue are important to decide an appropriate suture material.

  7. Mechanical Behavior of Bio-inspired Model Suture Joints

    Science.gov (United States)

    Li, Yaning; Lin, Erica; Ortiz, Christine; Boyce, Mary

    2012-02-01

    Suture joints of varying degrees of geometric complexity are prevalent throughout nature as a means of joining structural elements while providing locally tailored mechanical performance. Here, micromechanical models of general trapezoidal waveforms of varying hierarchy are formulated to reveal the role of geometric complexity in governing stiffness, strength, toughness and corresponding deformation and failure mechanisms. Physical constructs of model composite suture systems are fabricated via multi-material 3D printing (Object Connex500). Tensile tests are conducted on samples covering a range in geometry, thus providing quantitative measures of stiffness, strength, and failure. The experiments include direct visualization of the deformation and failure mechanisms and their progression, as well as their dependence on suture geometry, showing the interplay between shear and tension/compression of the interfacial layers and tension of the skeletal teeth and the transition in failure modes with geometry. The results provide quantitative guidelines for the design and tailoring of suture geometry to achieve the desired mechanical properties and also facilitate understanding of suture growth and fusion, and evolutionary phenotype.

  8. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  9. Radon diffusion chamber

    International Nuclear Information System (INIS)

    Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.

    1986-01-01

    The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4

  10. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  11. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  12. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  14. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  15. Classification of posterior vitreous detachment

    Science.gov (United States)

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2014-01-01

    Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography (OCT). By biomicroscopy, the vitreous condition is determined based on the presence or absence of a PVD. The PVD then is classified as either a complete posterior vitreous detachment (C-PVD) or a partial posterior vitreous detachment (P-PVD). A C-PVD is further divided into a C-PVD with collapse and a C-PVD without collapse, while a P-PVD is divided into a P-PVD with shrinkage of the posterior hyaloid membrane (P-PVD with shrinkage) and a P-PVD without shrinkage of the posterior hyaloid membrane (P-PVD without shrinkage). A P-PVD without shrinkage has a subtype characterized by vitreous gel attachment through the premacular hole in a posterior hyaloid membrane to the macula (P-PVD without shrinkage [M]). By OCT, a shallow PVD is classified as the absence of a shallow PVD or as a shallow PVD. A shallow PVD is then subclassified as a shallow PVD without shrinkage of the posterior vitreous cortex, a shallow PVD with shrinkage of the posterior vitreous cortex, and a peripheral shallow PVD. A shallow PVD without shrinkage of the posterior vitreous cortex has two subtypes: an age-related shallow PVD and a perifoveal PVD associated with a macular hole. PMID:24376338

  16. Water-tight knee arthrotomy closure: comparison of a novel single bidirectional barbed self-retaining running suture versus conventional interrupted sutures.

    Science.gov (United States)

    Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred

    2011-03-01

    Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.

  17. Primary Posterior Mediastinum Hydatid Cyst

    International Nuclear Information System (INIS)

    Ahmed, M.; Eid, A. F.; Sheikh, M. Y.; Yiannakou, N.

    2014-01-01

    Primary posterior mediastinal hydatid cyst is a serious health problem for the Mediterranean countries. We diagnosed a case of a 46-year-old female with a primary posterior mediastinum hydatid cyst on CT and MRI. It was provisionally identified as either a hydatid cyst or bronchogenic cyst or neuroenteric cyst. CT guided aspiration with 18 gauge needle confirmed as hydatid sand. This is very rare in this population but it should be kept in mind when one is looking at any cyst in the posterior mediastinum. (author)

  18. EVALUATION OF ADJUSTABLE SUTURE TECHNIQUE IN OUTCOME OF PTOSIS SURGERY

    Directory of Open Access Journals (Sweden)

    Nagaraju

    2015-10-01

    Full Text Available AIM: To evaluate the outcome of adjustable suture technique in ptosis surgery. INTRODUCTION : Surgical management of blepharoptosis is indicated in multiple situations and the post - operative outcomes can be as variable as the indications for surgery. Adjustable suture techniques in ptosis repair have been introduced and variable efficacies have been reported. MATERIALS AND METHODS: A retrospective case review of medical records from June 2010 to May 2011 (12 months of 5 eyes of 5 consecutive patients operated by a single surgeon at a Tertiary Eye care center in South India were reviewed. The clinical profile of patients included was r ecorded and results of adjustable suture technique described by Borman and collegues for these patients was reported. RESULTS: 5 eyes of 5 patients underwent adjustable suture ptosis repair in the study duration. 4 patients with moderate and 1 with severe ptosis, all having good levator function were diagnosed to have c ongenital ptosis in 3 cases and a cquired involutional ptosis in 2 cases. All 5 cases had a satisfactory outcome at day 4 post - operative after adjustment of lid height in the out - patient clini c. 1 patient with acquired involutional ptosis, identified with levator dehiscence intra - operatively had overcorrection at 6 months warranting re - surgery while the other 4 patients had satisfactory cosmetic lid height and functional outcome at 6 months fol low up after the adjustable suture technique for ptosis repair. CONCLUSION: Use of adjustable sutures in ptosis surgery can eliminate the intraoperative lid factors that can lead to unpredictable results. The technique described is easy to adapt and perfor m and can give repeatable and well acceptable results in the properly selected cases

  19. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  20. Heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The CERN Heavy liquid bubble chamber being installed in the north experimental hall at the PS. On the left, the 1180 litre body; in the centre the magnet, which can produce a field of 26 800 gauss; on the right the expansion mechanism.

  1. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Ferrari, A.

    2002-01-01

    The design and construction of the large drift chamber of the KLOE experiment is presented. The track reconstruction is described, together with the calibration method and the monitoring systems. The stability of operation and the performance are studied with samples of e + e - , K S K L and K + K - events

  2. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  3. Drift Chambers detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez laso, L.

    1989-01-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs

  4. OPAL Muon Chamber

    CERN Multimedia

    OPAL was one of the 4 experiments installed at the LEP particle accelerator from 1989 to 2000. This is a slice of the outermost layer of OPAL : the muon chambers. This outside layer detects particles which are not stopped by the previous layers. These are mostly muons.

  5. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  6. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  7. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  8. Ion chamber instrument

    International Nuclear Information System (INIS)

    Stephan, D.H.

    1975-01-01

    An electrical ionization chamber is described having a self-supporting wall of cellular material which is of uniform areal density and formed of material, such as foamed polystyrene, having an average effective atomic number between about 4 and about 9, and easily replaceable when on the instrument. (auth)

  9. Review of straw chambers

    International Nuclear Information System (INIS)

    Toki, W.H.

    1990-03-01

    This is a review of straw chambers used in the HRS, MAC, Mark III, CLEO, AMY, and TPC e + e - experiments. The straws are 6--8 mm in diameter, operate at 1--4 atmospheres and obtain resolutions of 45--100 microns. The designs and constructions are summarized and possible improvements discussed

  10. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  11. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  12. A reusable suture anchor for arthroscopy psychomotor skills training.

    Science.gov (United States)

    Tillett, Edward D; Rogers, Rainie; Nyland, John

    2003-03-01

    For residents to adequately develop the early arthroscopy psychomotor skills required to better learn how to manage the improvisational situations they will encounter during actual patient cases, they need to experience sufficient practice repetitions within a contextually relevant environment. Unfortunately, the cost of suture anchors can be a practice repetition-limiting factor in learning arthroscopic knot-tying techniques. We describe a technique for creating inexpensive reusable suture anchors and provide an example of their application to repair the anterior glenoid labrum during an arthroscopy psychomotor skills laboratory training session.

  13. Extensile posterior approach to the ankle with detachment of the achilles tendon for oncologic indications.

    Science.gov (United States)

    Maheshwari, Aditya V; Walters, Jason A; Henshaw, Robert M

    2012-05-01

    We describe an extensile posterior approach to the ankle with detachment of the Achilles tendon for resection of extensive tumors involving the posterior ankle. To the best of our knowledge, this approach and its results have not been reported for oncologic indications. The surgical technique involved detachment of the Achilles tendon, tumor resection and reconstruction of the Achilles tendon with anchor sutures, and was used in six patients. The diagnosis was pigmented villonodular synovitis (5) and chondroblastoma (1). At a mean of 6 (range, 2 to 10) years followup, all patients were free from tumor. All patients could walk an unlimited amount without any support. There were no problems with Achilles incompetence. The mean Musculoskeletal Tumor Society score was 97 ± 4.2% (range, 90 to 100) and the mean Achilles Tendon Total Rupture Score was 95 ± 5.7 (range, 87 to 100). One patient with screwed suture anchors had backing out of two anchors along with deep infection, requiring surgical debridement and anchor removal. One other patient had a post-traumatic small wound dehiscence which responded to local wound care. Excellent exposure, tumor control and patient function were achieved by this approach in a select group of patients. The surgical technique described in this report offers another alternative for an extensile posterior approach to the ankle and/or subtalar joints.

  14. Effect of robotic manipulation on unidirectional barbed suture integrity: evaluation of tensile strength and sliding force.

    Science.gov (United States)

    Kaushik, Dharam; Clay, Kevin; Hossain, S G M; Park, Eugene; Nelson, Carl A; LaGrange, Chad A

    2012-06-01

    One of the more challenging portions of robot-assisted radical prostatectomy (RARP) is the urethrovesical anastomosis. Because of this, a unidirectional absorbable barbed suture (V-Loc(™)) has been used to complete the anastomosis with better efficiency and less tension. The effect of robotic needle driver manipulation on barbed suture is unknown. Therefore, the aim of this study is to determine whether robotic manipulation decreases the tensile strength and peak sliding force of V-Loc barbed suture. Fifty-six V-Loc sutures were compared with 56 Maxon sutures. All sutures were 3-0 caliber. Half of the sutures in each group were manipulated with a da Vinci(®) robot large needle driver five times over a 5 cm length of suture. The other half was not manipulated. Breaking force was determined by placing sutures in a Bose ElectroForce load testing device. For sliding force testing, 28 V-Loc sutures were manipulated in the same fashion and compared with 28 nonmanipulated V-Loc sutures. Peak force needed to make the suture slip backward in porcine small intestine was determined to be the sliding force. Scanning electron microscopy of the barbs before and after robotic manipulation was also performed. The mean difference in breaking forces for manipulated vs nonmanipulated Maxon sutures was 4.52 N (P=0.004). The mean difference in breaking forces for manipulated vs nonmanipulated V-Loc sutures was 1.30 N (P=0.046). The manipulated V-Loc group demonstrated a lower peak sliding force compared with the nonmanipulated group (0.76 vs 0.88 N, P=0.199). Electron microscopy revealed minor structural damage to the barbs and suture. Tensile strength and peak sliding force of V-Loc suture is decreased by robotic manipulation. This is likely because of structural damage to the suture and barbs. This structural damage, however, is likely not clinically significant.

  15. Interrupted or continuous-intradermal suturing? Statistical analysis of postoperative scars

    Directory of Open Access Journals (Sweden)

    Elif Sarı

    2014-12-01

    Full Text Available Background and Design: Postoperative scar development is an important problem for patients treated in plastic surgery clinics. Most patients think that continuous intradermal suturing is superior to interrupted suturing because they assume that it creates less scarring. We evaluated scars that form following intradermal and interrupted suturing. This article presents our controlled study that objectively compared the scars on patients' faces using a wound evaluation scale. Materials and Methods: Thirty-five patients, who had undergone operations on the bilateral cheeks, were included in this study. Thirty patients were female; five patients were male. Their mean age was 40.05 years. The average scar evaluation time after surgery was 9.05 months. Elliptical excisions were made on the lesions under local anesthesia. The incisions on the right cheeks were sutured with 6/0 monofilament nonabsorbable sutures using the continuous intradermal suturing technique. The left cheek incisions were sutured with same sutures using the interrupted suturing method. Results: The patients were evaluated 7–11 months after operation (mean: 9.05 months using the Stony Brook Scar Evaluation Scale. A Related Samples T-test was used for statistical evaluation of the differences between the suturing techniques. No significant differences were noted in scar formation between the two suturing methods (p>0.05. Conclusion: We found no differences in scar formation between the two frequently used suturing techniques studied here. We believe that the suturing technique is a less important determinant of scar formation than are other factors.

  16. Posterior fossa meningioma (surgical experiences)

    African Journals Online (AJOL)

    Wael M. Moussa

    2012-08-27

    Aug 27, 2012 ... of the CNS, representing about a third of brain tumors. They arise from the ... subtypes based on cell structure.1–4 In 1979, the World Health. Organization .... anterior or posterior to the internal auditory meatus), petrocli-.

  17. Variations of posterior vitreous detachment

    OpenAIRE

    Kakehashi, A.; Kado, M.; Akiba, J.; Hirokawa, H.

    1997-01-01

    AIMS—To identify variations in posterior vitreous detachment (PVD) and establish a clinical classification system for PVD.
METHODS—400 consecutive eyes were examined using biomicroscopy and vitreous photography and classified the PVD variations—complete PVD with collapse, complete PVD without collapse, partial PVD with thickened posterior vitreous cortex (TPVC), or partial PVD without TPVC.
RESULTS—In each PVD type, the most frequently seen ocular pathologies were as follows: in complete PVD ...

  18. Absorbable Polydioxanone (PDS) suture provides fewer wound complications than polyester (ethibond) suture in acute Tendo-Achilles rupture repair

    LENUS (Irish Health Repository)

    Baig, M N

    2017-05-01

    We prospectively studied acute Achilles tendon rupture in patients over a two 2-year period and reviewed the causes, outcome and complications. There were 53 patients included with acute Achilles rupture with minimum follow up period of 6 months. We compared the outcomes including infection rate and Boyden score between the two groups repaired by Polydioxanone and Polyester respectively. All infected cases had a suture repair using the polyester suture. The difference in the infection rate was highly significant between the 2 groups (p=0.001). All 34 patients (100%) in the PDS group had good \\/ excellent results based on the Boyden clinical assessment. Conversely, only 16 patients 9(68.4%) had good or excellent results IN Polyester repair group. Patients treated with a non- absorbable suture (ethibond) material for repair had a higher incidence infection and worse Boyden scores than the absorbable PDS group.

  19. Biomechanical Comparison of Modified Suture Bridge Using Rip-Stop versus Traditional Suture Bridge for Rotator Cuff Repair

    Directory of Open Access Journals (Sweden)

    ZiYing Wu

    2016-01-01

    Full Text Available Purpose. To compare the biomechanical properties of 3 suture-bridge techniques for rotator cuff repair. Methods. Twelve pair-matched fresh-frozen shoulder specimens were randomized to 3 groups of different repair types: the medially Knotted Suture Bridge (KSB, the medially Untied Suture Bridge (USB, and the Modified Suture Bridge (MSB. Cyclic loading and load-to-failure test were performed. Parameters of elongation, stiffness, load at failure, and mode of failure were recorded. Results. The MSB technique had the significantly greatest load to failure (515.6±78.0 N, P=0.04 for KSB group; P<0.001 for USB group, stiffness (58.0±10.7 N/mm, P=0.005 for KSB group; P<0.001 for USB group, and lowest elongation (1.49±0.39 mm, P=0.009 for KSB group; P=0.001 for USB group among 3 groups. The KSB repair had significantly higher ultimate load (443.5±65.0 N than USB repair (363.5±52.3 N, P=0.024. However, there was no statistical difference in stiffness and elongation between KSB and USB technique (P=0.396 for stiffness and P=0.242 for elongation, resp.. The failure mode for all specimens was suture pulling through the cuff tendon. Conclusions. Our modified suture bridge technique (MSB may provide enhanced biomechanical properties when compared with medially knotted or knotless repair. Clinical Relevance. Our modified technique may represent a promising alternative in arthroscopic rotator cuff repair.

  20. Transvaginal bladder neck closure with posterior urethral flap for devastated urethra.

    Science.gov (United States)

    Rovner, Eric S; Goudelocke, Colin M; Gilchrist, Alienor; Lebed, Brett

    2011-07-01

    To present a modified transvaginal bladder neck closure (TV BNC) technique using a posterior urethral flap to minimize the potential risk of ureteral injury and fistula formation. Urethral and bladder neck destruction owing to chronic indwelling urethral catheters in female neurogenic patients is a devastating complication. A retrospective review was performed of all patients undergoing TV BNC at a single institution during a 3-year period. All patients had had a nonfunctional or destroyed urethra because of a long-term indwelling urethral catheter. In brief, the devastated outlet was closed using the dorsally bivalved urethra as a flap that was rotated cephalad onto the incised anterior bladder wall for closure, thereby rotating the suture line high into the retropubic space. A postoperative cystogram was obtained at 2-3 weeks. A total of 11 consecutive female patients with a devastated outlet underwent TV BNC, as described, with placement of a suprapubic tube. One patient experienced failure at 6 weeks postoperatively. The mean follow-up for the entire cohort was 9.6 months (range 1-36). Serial upper tract imaging at the last follow-up visit revealed no new hydroureteronephrosis. The results of our study have shown that TV BNC with a posterior urethral flap provides satisfactory early results. This technique creates a suture line far removed from the ureteral orifices, minimizing the risk of upper tract injury during closure. Also, the rotation of the posterior urethra onto the anterior bladder wall secures the suture line high into the retropubic space, minimizing the risk of failure and postoperative fistula formation. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Achondroplasia with multiple-suture craniosynostosis: a report of a new case of this rare association

    NARCIS (Netherlands)

    Bessenyei, Beáta; Nagy, Andrea; Balogh, Erzsébet; Novák, László; Bognár, László; Knegt, Alida C.; Oláh, Eva

    2013-01-01

    We report on a female patient with an exceedingly rare combination of achondroplasia and multiple-suture craniosynostosis. Besides the specific features of achondroplasia, synostosis of the metopic, coronal, lambdoid, and squamosal sutures was found. Series of neurosurgical interventions were

  2. Healing of the suture line in the irradiated small intestine

    International Nuclear Information System (INIS)

    Da Costa, S.A.

    1989-01-01

    With the help of data from literature the author goes more deeply into the aetiology, treatment and possible prevention of lesions of the small intestine related to preceding irradiation. In a clinical retrospective study at twenty patients who, after irradiation of the abdominal and pelvic areas, have been submitted to abdominal surgery, the relation is studied between predistion factors for gastrointestinal complications after irradiation, the surgeries applied in case of small-intestine problems and postoperative complications. The third part of the thesis covers an experimental part in which the healing process of suture line in the terminal ileum has been studied after resection and reanastomosis in previously irradiated bowel of the rat. It was investigated whether differences occurred in the healing process of suture line after various periods - 4, 10 and 40 weeks, after irradiation. Also comparison took place with a control group which underwent a similar procedure with the exception of the radiation treatment, which was simulated in this group. In a second experiment it was investigated if the healing process of suture line depends on the type of anastomosis. An end-to-end anastomosis was chosen versus side-to-side anastomosis. Also in this experiment an irradiated group was compared with a control group. Furthermore a method was developed for performing micro-angiographies of the rat intestine in order to demonstrate obliteration of blood vessels in irradiated intestine and to assess neovascularization in the intestinal wall at the suture line. (author). 84 refs.; 18 figs.; 27 tabs

  3. Comparison of Subcuticular Suture Materials in Cesarean Skin Closure

    Directory of Open Access Journals (Sweden)

    Pınar Solmaz Hasdemir

    2015-01-01

    Full Text Available Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure.

  4. non absorbable sutures in the urinary bladder resulting

    African Journals Online (AJOL)

    The vesical calculus. Urol Clin North AM. 2000, 27:333-346. 3. Evans JW, Chapple CR, Ralph DJ, Millory EJ: Bladder calculus formation as a complication of the Stamey procedure. Br J Urol 1990,. 65:580-582. 4. Sheng-Tsun Su, He-Fu Haung, Shu-Fen. Chang. Encrusted Bladder stone on Non- absorbable sutures after a ...

  5. Polymeric Medical Sutures: An Exploration of Polymers and Green Chemistry

    Science.gov (United States)

    Knutson, Cassandra M.; Schneiderman, Deborah K.; Yu, Ming; Javner, Cassidy H.; Distefano, Mark D.; Wissinger, Jane E.

    2017-01-01

    With new K-12 national science standards emerging, there is an increased need for experiments that integrate engineering into the context of society. Here we describe a chemistry experiment that combines science and engineering principles while introducing basic polymer and green chemistry concepts. Using medical sutures as a platform for…

  6. Hyperammonemic encephalopathy due to suture line breakdown after bladder operation.

    Science.gov (United States)

    Boogerd, W; Zoetmulder, F A; Moffie, D

    1990-01-01

    A patient is described with a severe encephalopathy and hyperammonemia in absence of liver dysfunction, attributed to urine absorption into the systemic circulation due to suture line breakdown after bladder dome resection. At autopsy characteristic Alzheimer type II astrocytes were found in the basal ganglia.

  7. A Simple Suturing Technique for Laparoscopic Ligation of Vascular Pedicles

    Directory of Open Access Journals (Sweden)

    Keith A. Aqua

    1996-01-01

    Full Text Available We report on the performance of 348 adnexectomies and 35 uterine artery ligations for both benign and malignant disease using a simple laparoscopic suturing technique. Only 5-mm ports are required, and there was no morbidity directly associated with this approach. The procedure can be performed quickly, is relatively inexpensive, and allows hysterectomy and oophorectomy to be performed without bipolar electrocautery.

  8. Stress-Softening and Residual Strain Effects in Suture Materials

    Directory of Open Access Journals (Sweden)

    Alex Elías-Zúñiga

    2013-01-01

    Full Text Available This work focuses on the experimental characterization of suture material samples of MonoPlus, Monosyn, polyglycolic acid, polydioxanone 2–0, polydioxanone 4–0, poly(glycolide-co-epsilon-caprolactone, nylon, and polypropylene when subjected to cyclic loading and unloading conditions. It is found that all tested suture materials exhibit stress-softening and residual strain effects related to the microstructural material damage upon deformation from the natural, undistorted state of the virgin suture material. To predict experimental observations, a new constitutive material model that takes into account stress-softening and residual strain effects is developed. The basis of this model is the inclusion of a phenomenological nonmonotonous softening function that depends on the strain intensity between loading and unloading cycles. The theory is illustrated by modifying the non-Gaussian average-stretch, full-network model to capture stress-softening and residual strains by using pseudoelasticity concepts. It is shown that results obtained from theoretical simulations compare well with suture material experimental data.

  9. Multiwire proportional chamber development

    Science.gov (United States)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  10. Radial semiconductor drift chambers

    International Nuclear Information System (INIS)

    Rawlings, K.J.

    1987-01-01

    The conditions under which the energy resolution of a radial semiconductor drift chamber based detector system becomes dominated by the step noise from the detector dark current have been investigated. To minimise the drift chamber dark current attention should be paid to carrier generation at Si/SiO 2 interfaces. This consideration conflicts with the desire to reduce the signal risetime: a higher drift field for shorter signal pulses requires a larger area of SiO 2 . Calculations for the single shaping and pseudo Gaussian passive filters indicate that for the same degree of signal risetime sensitivity in a system dominated by the step noise from the detector dark current, the pseudo Gaussian filter gives only a 3% improvement in signal/noise and 12% improvement in rate capability compared with the single shaper performance. (orig.)

  11. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  12. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  13. Double chambered right ventricle

    International Nuclear Information System (INIS)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung

    1983-01-01

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure

  14. Double chambered right ventricle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure.

  15. Argus drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Danilov, M; Nagovizin, V; Hasemann, H; Michel, E; Schmidt-Parzefall, W; Wurth, R; Kim, P

    1983-11-15

    The ARGUS detector came into operation at the DORIS-II e/sup +/s/sup -/ storage ring at the end of 1982. Its two meter long drift chamber contains 5940 sense and 24588 field wires organized in uniform 18x18.8 mm/sup 2/ drift cells filling the whole volume. These cells form 36 layers, 18 of which provide stereo views. Each sense wire is equipped with a single hit TDC and ADC for coordinate and dE/dx measurements. The chamber is operated with propane to improve momentum and dE/dx resolution. The drift chamber design and initial performance are presented. With a very crude space-time relation approximation and without all the necessary corrections applied a spatial resolution of about 200 ..mu..m was obtained for half of the drift cell volume. Further corrections should improve this result. An intrinsic dE/dx resolution of 4.2% and an actual resolution of 5% were obtained for cosmic muons and also for Bhabha scattered electrons. An actual dE/dx resolution of 5.6% was obtained for pions from e/sup +/e/sup -/ annihilation data with almost no track selection. A relativistic rise of 30% was observed in good agreement with theory. The long-term stability is still to be investigated.

  16. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  17. Nonsuturing or Skin Adhesives versus Suturing of the Perineal Skin After Childbirth: A Systematic Review

    NARCIS (Netherlands)

    Seijmonsbergen-Schermers, A.E.; Sahami, S.; Lucas, C.; de Jonge, A.

    2015-01-01

    Background: Suturing of perineal trauma after childbirth can cause problems such as pain, discomfort because of tight sutures, the need for suture removal, and dyspareunia. It is unclear whether leaving the perineal skin unsutured or using skin adhesives might prevent these problems. Methods:

  18. Nonsuturing or Skin Adhesives versus Suturing of the Perineal Skin After Childbirth: A Systematic Review

    NARCIS (Netherlands)

    Seijmonsbergen-Schermers, Anna E.; Sahami, Saloomeh; Lucas, Cees; Jonge, Ank de

    2015-01-01

    Suturing of perineal trauma after childbirth can cause problems such as pain, discomfort because of tight sutures, the need for suture removal, and dyspareunia. It is unclear whether leaving the perineal skin unsutured or using skin adhesives might prevent these problems. CENTRAL, MEDLINE, EMBASE,

  19. Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin.

    Science.gov (United States)

    Li, Haidong; Song, Tao

    2018-01-29

    To introduce nickel-titanium wire as suture material for closure of incisions in cleft lip procedures. Closure of skin incisions using nickel-titanium wire as suture material, with postoperative follow-up wound evaluation. There was excellent patient satisfaction and good cosmetic outcome. Nickel-titanium wire is an excellent alternative for suture closure of cleft lip surgical incisions.

  20. Development of a penetration friction apparatus (PFA) to measure the frictional performance of surgical suture

    NARCIS (Netherlands)

    Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile

    2017-01-01

    Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their

  1. Caudal Septal Stabilization Suturing Technique to Treat Crooked Noses.

    Science.gov (United States)

    Baykal, Bahadir; Erdim, Ibrahim; Guvey, Ali; Oghan, Fatih; Kayhan, Fatma Tulin

    2016-10-01

    To rotate the nasal axis and septum to the midline using an L-strut graft and a novel caudal septal stabilization suturing technique to treat crooked noses. Thirty-six patients were included in the study. First, an L-strut graft was prepared by excising the deviated cartilage site in all patients. Second, multiple stabilization suturing, which we describe as a caudal septal stabilization suturing technique with a "fishing net"-like appearance, was applied between the anterior nasal spine and caudal septum in all patients. This new surgical technique, used to rotate the caudal septum, was applied to 22 I-type and 14 C-type crooked noses. Correction rates for the crooked noses were compared between the 2 inclination types with angular estimations. Deviation angles were measured using the AutoCAD 2012 software package and frontal (anterior) views, with the Frankfurt horizontal line parallel to the ground. Nasal axis angles showing angle improvement graded 4 categories as excellent, good, acceptable, and unsuccessful for evaluations at 6 months after surgery in the study. The success rate in the C-type nasal inclination was 86.7% (±21.9) and 88% (±16.7) in the I-type. The overall success rate of L-strut grafting and caudal septal stabilization suturing in crooked nose surgeries was 87.5% (±18.6). "Unsuccessful" results were not reported in any of the patients. L-strut grafting and caudal septal stabilization suturing techniques are efficacious in crooked noses according to objective measurement analysis results. However, a longer follow-up duration in a larger patient population is needed.

  2. Arthroscopic repair of lateral ankle ligament complex by suture anchor.

    Science.gov (United States)

    Wang, Jingwei; Hua, Yinghui; Chen, Shiyi; Li, Hongyun; Zhang, Jian; Li, Yunxia

    2014-06-01

    Arthroscopic repair of the lateral ligament complex with suture anchors is increasingly used to treat chronic ankle instability (CAI). Our aims are (1) to analyze and evaluate the literature on arthroscopic suture anchor repair of the anterior talofibular ligament and (2) to conduct a systematic review of the clinical evidence on the reported outcomes and complications of treating CAI with this technique. We performed a systematic review of the literature using PubMed, Ovid, Elsevier ScienceDirect, Web of Science-Conference Proceedings Citation Index, and the Cochrane Database of Systematic Reviews from 1987 to September 2013. Clinical studies using the arthroscopic suture anchor technique to treat CAI were included. Outcome measures consisted of clinical assessment of postoperative ligament stability and complications. In addition, the methodologic quality of the included studies was assessed by use of the modified Coleman Methodology Score. After reviewing 371 studies, we identified 6 studies (5 retrospective case series and 1 prospective case series, all Level IV) that met the inclusion criteria, with a mean Coleman Methodology Score of 71.8 ± 7.52 (range, 63 to 82). In these studies 178 patients (179 ankles) underwent arthroscopic suture anchor repair of the anterior talofibular ligament with a mean follow-up period of 38.9 months (range, 6 to 117.6 months). All patients were reported to have subjective improvement of their ankle instability, with complications in 31 cases. Studies of arthroscopic suture anchor technique to treat CAI are sparse, with moderate mean methodologic quality. The included studies suggest that the arthroscopic technique is a feasible procedure to restore ankle stability; however, on the basis of our review, this technique seems to be associated with a relatively high complication rate. Extensive cadaveric studies, clinical trials, and comparative studies comparing arthroscopic and open repair should be performed in the future. Level

  3. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  4. Endoscopic management of posterior epistaxis.

    Science.gov (United States)

    Paul, J; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-04-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26-50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of the bleeding vessel. Of these, in four cases unsuspected diagnosis was made. Of the remaining 19, in three patients, the bleeding point could not be localized accurately and these patients were managed by anteroposterior packing. The rest of the 16 patients were managed by endoscopic cauterization. In four patients, there was recurrence of bleeding within 24 h. In one of these, cauterization controlled the bleeding while in the rest nasal packing had to be resorted to. Thus, of the 23 patients of posterior epistaxis subjected to nasal endoscopy, we could avoid nasal packing in 17 (74%). To conclude, endoscopic nasal cauterization is recommended as the first line to treatment in all cases of posterior epistaxis. This will not only prevent the uncomfortable and potentially dangerous nasal packing but also help in finding the underlying pathology.

  5. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  6. Sandwich wound closure reduces the risk of cerebrospinal fluid leaks in posterior fossa surgery

    Directory of Open Access Journals (Sweden)

    Verena Heymanns

    2016-07-01

    Full Text Available Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8% in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark, Gelfoam® (Pfizer Inc., New York, NY, USA and polymethylmethacrylate (osteoclastic craniotomy. The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

  7. The Incidence and Topographic Distribution of Sutures Including Wormian Bones in Human Skulls.

    Science.gov (United States)

    Cirpan, Sibel; Aksu, Funda; Mas, Nuket

    2015-07-01

    The Wormian Bones are accessory bones located within the cranial sutures and fontanelles. The present article examines the incidence of Wormian Bones and compares the number and topographic distribution between the sutures including Wormian Bones in skulls of West Anatolian Population. One hundred fifty crania were examined. The parameters evaluated in the present study were as follows: the rate of skulls including Wormian Bones; the topographic distribution and frequencies of the sutures including Wormian Bones; the number of these sutures for each skull; the name and number of sutures that were bilaterally and symmetrically located on the right and left side of skull (paired sutures) and which coincidentally had Wormian Bones for each skull; the differences of frequencies between the paired sutures including Wormian Bones. The rate of skulls including Wormian Bones was determined as 59.3%. The maximum and minimum numbers of sutures, including Wormian Bones, were 6 in 1 skull and 1 in each of 30 skulls, respectively. The maximum and minimum rates of sutures that had Wormian Bones were found in left lambdoid 40.7% and right occipitomastoid 1.3% sutures, respectively. There was only a significant difference between the rate of right and left squamous sutures (P = 0.04). Forty-five skulls were including 55 pairs of bilaterally and symmetrically located sutures that coincidentally had Wormian Bones in each pair. Each of 35 skulls had 1 pair of sutures including Wormian Bones and each of 10 skulls had 2 pairs. In the present study, the rate of Wormian Bones was determined as 59.3% in West Anatolian Population. This incidence rate is considerably lower than the other reports, and it may be as a result of racial variations. These divergent bones were more frequently found in left lambdoid sutures (40.7%) and less frequently in right occipitomastoid sutures (1.3%). This study may guide the investigators dealing with the neurosurgery, orthopedy, radiology, anatomy, and

  8. Epidural hematomas of posterior fossa

    Directory of Open Access Journals (Sweden)

    Radulović Danilo

    2004-01-01

    Full Text Available Background. Posterior fossa epidural hematomas represent 7-14% of all traumatic intracranial epidural hematomas. They are most frequently encountered posttraumatic mass lesions in the posterior fossa. The aim of this study was to identify clinical features that could lead to the early diagnosis of posterior fossa epidural hematoma. Methods. Between 1980 and 2002, 28 patients with epidural hematoma of the posterior fossa were operated on at the Institute for Neurosurgery, Belgrade. Clinical course neuroradiological investigations, and the results of surgical treatment of the patients with posterior fossa epidural hematomas were analyzed retrospectively. Results. Almost two thirds of patients were younger than 16 years of age. In 20 cases injury was caused by a fall, in 6 cases by a traffic accident, and in 2 by the assault. Clinical course was subacute or chronic in two thirds of the patients. On the admission Glasgow Coma Scale was 7 or less in 9 injured, 8-14 in 14 injured, and 15 in 5 injured patients. Linear fracture of the occipital bone was radiographically evident in 19 patients, but was intraoperatively encountered in all the patients except for a 4-year old child. In 25 patients the diagnosis was established by computer assisted tomography (CAT and in 3 by vertebral angiography. All the patients were operated on via suboccipital craniotomy. Four injured patients who were preoperatively comatose were with lethal outcome. Postoperatively, 24 patients were with sufficient neurologic recovery. Conclusion. Posterior fossa epidural hematoma should be suspected in cases of occipital injury, consciousness disturbances, and occipital bone fracture. In such cases urgent CAT-scan is recommended. Early recognition early diagnosis, and prompt treatment are crucial for good neurological recovery after surgery.

  9. Unsuccessful outcomes after posterior urethroplasty.

    Science.gov (United States)

    Engel, Oliver; Fisch, Margit

    2015-03-01

    Posterior urethroplasty is the most common strategy for the treatment of post-traumatic urethral injuries. Especially in younger patients, post-traumatic injuries are a common reason for urethral strictures caused by road traffic accidents, with pelvic fracture or direct trauma to the perineum. In many cases early endoscopic realignment is the first attempt to restore the junction between proximal and distal urethra, but in some cases primary realignment is not possible or not enough to treat the urethral injury. In these cases suprapubic cystostomy alone and delayed repair by stricture excision and posterior urethroplasty is an alternative procedure to minimise the risk of stricture recurrence.

  10. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  11. Case of colonic intussusception secondary to mobile cecum syndrome repaired by laparoscopic cecopexy using a barbed wound suture device.

    Science.gov (United States)

    Yamamoto, Tetsu; Tajima, Yoshitsugu; Hyakudomi, Ryoji; Hirayama, Takanori; Taniura, Takahito; Ishitobi, Kazunari; Hirahara, Noriyuki

    2017-09-21

    A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was compatible with the diagnosis of cecal intussusception. The intussusception was spontaneously resolved at that time, but it relapsed 6 mo later. The patient underwent a successful colonoscopic disinvagination; there was no evidence of neoplastic or inflammatory lesions in the colon and terminal ileum. The patient underwent laparoscopic surgery for recurring cecal intussusception. During laparoscopy, we observed an unfixed cecum on the posterior peritoneum (i.e. a mobile cecum). Thus, we performed laparoscopic appendectomy and cecopexy with a lateral peritoneal flap using a barbed wound suture device. The patient's post-operative course was uneventful, and he continued to do well without recurrence at 10 mo after surgery. Laparoscopic cecopexy using a barbed wound suture device is a simple and reliable procedure that can be the treatment of choice for recurrent cecal intussusception associated with a mobile cecum.

  12. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  13. Space plasma simulation chamber

    International Nuclear Information System (INIS)

    1986-01-01

    Scientific results of experiments and tests of instruments performed with the Space Plasma Simulation Chamber and its facility are reviewed in the following six categories. 1. Tests of instruments on board rockets, satellites and balloons. 2. Plasma wave experiments. 3. Measurements of plasma particles. 4. Optical measurements. 5. Plasma production. 6. Space plasms simulations. This facility has been managed under Laboratory Space Plasma Comittee since 1969 and used by scientists in cooperative programs with universities and institutes all over country. A list of publications is attached. (author)

  14. Stability of Streamer Chamber

    Science.gov (United States)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi

    1982-08-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result.

  15. Stability of streamer chamber

    International Nuclear Information System (INIS)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi.

    1982-01-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result. (author)

  16. Development of a penetration friction apparatus (PFA) to measure the frictional performance of surgical suture.

    Science.gov (United States)

    Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile

    2017-10-01

    Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Timing of ectocranial suture activity in Gorilla gorilla as related to cranial volume and dental eruption.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2011-05-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.

  18. Randomized clinical trial comparing manual suture and different models of mechanical suture in the mimicking of bariatric surgery in swine

    Directory of Open Access Journals (Sweden)

    Fernandes MA

    2014-02-01

    Full Text Available Marcos AP Fernandes,1 Bruno MT Pereira,2 Sandra M Guimarães,1 Aline Paganelli,3 Carlos Manoel CT Pereira,1 Claudio Sergio Batista4 1Institute of Obesity and Advanced Video Laparoscopic Surgery of Petropolis, Rio de Janeiro, Brazil; 2Division of Trauma, University of Campinas, São Paulo, Brazil; 3Laboratório de Patologia Micron Cell Diagnóstico, Rio de Janeiro, Brazil; 4Department of Gynecology and Obstetrics, Faculty of Medicine of Petropolis, Rio de Janeiro, Brazil Context and objective: Variations in the ability of surgeons served as motivation for the development of devices that, overcoming individual differences, allow the techniques to be properly performed, and of which the end result was the best possible. Every technique must be reproduced reliably by the majority of surgeons for their results to be adopted and recognized as effective. The aim of this study was to compare the results, from the point of view of anatomic pathology, of manual sutures versus mechanical sutures using different models of linear mechanical staplers, in the procedure of gastroenteroanastomosis and enteroanastomosis in swine. Methods: Thirty-six healthy, adult, male Sus scrofa domesticus pigs, weighing between 20.7 and 25.5 kg, were used. The swine were randomly divided into four groups of nine pigs, according to the type of suture employed: group A, manual suture with Polysorb® 3-0 wire; group B, 80-shear linear stapler (Covidien® Gia 8038-S; group C, 75-shear linear stapler (Ethicon® Tlc 75; and group D, 75-shear linear stapler (Resource® Yq 75-3. A temporal study was established on the seventh postoperative day for histopathological analysis, and the degree of inflammation, fibrosis, and newly formed vessels, as well as the presence or absence of granulation tissue, foreign body granuloma, and necrosis were all evaluated qualitatively and semiquantitatively. The results were analyzed statistically. Results: Observations during the histopathological

  19. Prevention of posterior capsular opacification

    NARCIS (Netherlands)

    Nibourg, Lisanne M; Gelens, Edith; Kuijer, Roelof; Hooymans, Johanna Mm; van Kooten, Theo G; Koopmans, Steven A

    Posterior capsular opacification (PCO) is a common complication of cataract surgery. The development of PCO is due to a combination of the processes of proliferation, migration, and transdifferentiation of residual lens epithelial cells (LECs) on the lens capsule. In the past decades, various forms

  20. The ectopic posterior pituitary gland

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... crinology with short stature, delayed bone age and biochemical features suggestive of hypo pituitarism. Magnetic resonance imaging of the brain demonstrated a flattened anterior pituitary gland within the sella, associated with absence of the infundibular stalk and an ectopic posterior pituitary gland (Fig.

  1. [Posterior ceramic bonded partial restorations].

    Science.gov (United States)

    Mainjot, Amélie; Vanheusden, Alain

    2006-01-01

    Posterior ceramic bonded partial restorations are conservative and esthetic approaches for compromised teeth. Overlays constitute a less invasive alternative for tooth tissues than crown preparations. With inlays and onlays they are also indicated in case of full arch or quadrant rehabilitations including several teeth. This article screens indications and realization of this type of restorations.

  2. Council Chamber exhibition

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    To complete the revamp of CERN’s Council Chamber, a new exhibition is being installed just in time for the June Council meetings.   Panels will showcase highlights of CERN’s history, using some of the content prepared for the exhibitions marking 50 years of the PS, which were displayed in the main building last November. The previous photo exhibition in the Council Chamber stopped at the 1970s. To avoid the new panels becoming quickly out of date, photos are grouped together around specific infrastructures, rather than following a classic time-line. “We have put the focus on the accelerators – the world-class facilities that CERN has been offering researchers over the years, from the well-known large colliders to the lesser-known smaller facilities,” says Emma Sanders, who worked on the content. The new exhibition will be featured in a future issue of the Bulletin with photos and an interview with Fabienne Marcastel, designer of the exhibit...

  3. Cardiac chamber scintiscanning

    International Nuclear Information System (INIS)

    Goretzki, G.

    1981-01-01

    The two methods of cardiac chamber scintiscanning, i.e. 'first pass' and 'ECG-triggered' examinations, are explained and compared. Two tables indicate the most significant radiation doses of the applied radio tracers, i.e. 99m-Tc-pertechnetate and 99m-Tc-HSA, to which a patient is exposed. These averaged values are calculated from various data given in specialised literature. On the basis of data given in literature, an effective half-life of approximately 5 hours in the intravascular space was calculated for the erythrocytes labelled with technetium 99m. On this basis, the radiation doses for the patients due to 99m-Tc-labelled erythrocytes are estimated. The advantages and disadvantages of the two methods applied for cardiac chamber scintiscanning are put into contrast and compared with the advantages and disadvantages of the quantitative X-ray cardiography of the left heart. The still existing problems connected with the assessment of ECG-triggered images are discussed in detail. The author performed investigations of his own, which concerned the above-mentioned problems. (orig./MG) [de

  4. Posterior and anterior fixation of the urethra during robotic prostatectomy improves early continence rates.

    Science.gov (United States)

    Koliakos, Nikolaos; Mottrie, Alexandre; Buffi, Nicolo; De Naeyer, Geert; Willemsen, Pieter; Fonteyne, Etienne

    2010-02-01

    To investigate whether posterior and anterior fixation of the vesicourethral anastomosis during robotic radical prostatectomy (RRP) helps to establish continence earlier. Forty-seven consecutive patients undergoing RRP were randomized into two groups. The first group received a typical Van Velthoven vesicourethral anastomosis and the second group a modified anastomosis with posterior and anterior fixation. In this group the posterior fibrous tissues of the sphincter were sutured to the residual Denonvilliers' fascia. The anastomosis with two running sutures started at the 6 o'clock position on the bladder neck and continued upwards. Two-step stitching was done on the upper half of the anastomosis to ensure good stabilization of the bladder: a small portion of urethral stump followed by a deep haemostatic stitch on the plexus. Continence, as measured by patient self-reporting of the number of pads used per 24 h, was assessed 7 weeks after catheter removal, by telephone interview. The use of no pads or one pad was defined as "continent", two pads as "moderate incontinence" and more than two pads as "severe incontinence". At catheter removal, more patients in the fixation group were continent than in the Van Velthoven group [9/23 (39%) vs 3/24 (12.5%), p = 0.036]. At 7 weeks, continence was even better in the fixation group [15/23 (65%) vs 8/24 (33%), p = 0. 029]. The mean pad usage was less in the fixation group (1.43 vs 2.25, p = 0.032). The posterior and anterior fixation of the vesicourethral anastomosis during RRP results in an intact sphincteric mechanism, because no stretch is applied to the urethra, resulting in earlier continence.

  5. Efficacy of b-lynch brace suture in postpartum haemorrhage

    International Nuclear Information System (INIS)

    Tarique, S.; Wazir, S.; Moeen, G.

    2011-01-01

    Massive uncontrolled haemorrhage after childbirth is the leading cause of maternal death in developing countries. Postpartum haemorrhage is traditionally defined as blood loss of more than 500 ml after vaginal delivery and more than 1000 ml after caesarean section, but intraoperative estimation of blood loss is inaccurate. Uterine atony alone accounts for 75 - 90% of PPH. To estimate the effectiveness and safety of B-Lynch brace Suture in the management of primary postpartum haemorrhage (PPH). (author)

  6. Suture, synthetic, or biologic in contaminated ventral hernia repair.

    Science.gov (United States)

    Bondre, Ioana L; Holihan, Julie L; Askenasy, Erik P; Greenberg, Jacob A; Keith, Jerrod N; Martindale, Robert G; Roth, J Scott; Liang, Mike K

    2016-02-01

    Data are lacking to support the choice between suture, synthetic mesh, or biologic matrix in contaminated ventral hernia repair (VHR). We hypothesize that in contaminated VHR, suture repair is associated with the lowest rate of surgical site infection (SSI). A multicenter database of all open VHR performed at from 2010-2011 was reviewed. All patients with follow-up of 1 mo and longer were included. The primary outcome was SSI as defined by the Centers for Disease Control and Prevention. The secondary outcome was hernia recurrence (assessed clinically or radiographically). Multivariate analysis (stepwise regression for SSI and Cox proportional hazard model for recurrence) was performed. A total of 761 VHR were reviewed for a median (range) follow-up of 15 (1-50) mo: there were 291(38%) suture, 303 (40%) low-density and/or mid-density synthetic mesh, and 167(22%) biologic matrix repair. On univariate analysis, there were differences in the three groups including ethnicity, ASA, body mass index, institution, diabetes, primary versus incisional hernia, wound class, hernia size, prior VHR, fascial release, skin flaps, and acute repair. The unadjusted outcomes for SSI (15.1%; 17.8%; 21.0%; P = 0.280) and recurrence (17.8%; 13.5%; 21.5%; P = 0.074) were not statistically different between groups. On multivariate analysis, biologic matrix was associated with a nonsignificant reduction in both SSI and recurrences, whereas synthetic mesh associated with fewer recurrences compared to suture (hazard ratio = 0.60; P = 0.015) and nonsignificant increase in SSI. Interval estimates favored biologic matrix repair in contaminated VHR; however, these results were not statistically significant. In the absence of higher level evidence, surgeons should carefully balance risk, cost, and benefits in managing contaminated ventral hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Hematomas na fossa craniana posterior Haematomata in the posterior fossa

    Directory of Open Access Journals (Sweden)

    Mário S. Cademartori

    1969-09-01

    Full Text Available São relatados 6 casos de hematomas sub-tentorias (um de hematoma subdural crônico, quatro de hematomas intra-cerebelares, um de hematoma extra-dural. Salientando a pequena freqüência dos hematomas da fossa craniana posterior, o autor mostra a necessidade de vários exames complementares para o diagnóstico exato, indispensável para a aplicação de terapêutica cirúrgica adequada.Six cases of sub-tentorial haematomata (one chronic sub-dural, four intra-cerebellar, one extra-dural are reported. Emphasizing the relative rarity of haematomata in the posterior cranial fossa, the author claims the necessity of complementary examinations for proper diagnosis, indispensable for adequate surgical treatment.

  8. Subgaleal Retention Sutures: Internal Pressure Dressing Technique for Dolenc Approach.

    Science.gov (United States)

    Burrows, Anthony M; Rayan, Tarek; Van Gompel, Jamie J

    2017-08-01

    Extradural approach to the cavernous sinus, the "Dolenc" approach recognizing its developing Dr. Vinko Dolenc, is a critically important skull base approach. However, resection of the lateral wall of the cavernous sinus, most commonly for cavernous sinus meningiomas, results commonly in a defect that often cannot be reconstructed in a water-tight fashion. This may result in troublesome pseudomeningocele postoperatively. To describe a technique designed to mitigate the development of pseudomeningocele. We found the Dolenc approach critical for resection of cavernous lesions. However, a number of pseudomeningoceles were managed with prolonged external pressure wrapping in the early cohort. Therefore, we incorporated subgaleal to muscular sutures, which were designed to close this potential space and retrospectively analyzed our results. Twenty-one patients treated with a Dolenc approach and resection of the lateral wall of the cavernous sinus over a 2-year period were included. Prior to incorporation of this technique, 12 patients were treated and 3 (25%) experienced postoperative pseudomeningoceles requiring multiple clinic visits and frequent dressing. After incorporation of subgaleal retention sutures, no patient (0%) experienced this complication. Although basic, subgaleal to temporalis muscle retention sutures likely aid in eliminating this potential dead space, thereby preventing patient distress postoperatively. This technique is simple and further emphasizes the importance of dead space elimination in complex closures. Copyright © 2017 by the Congress of Neurological Surgeons

  9. A Comfortable Solution To Tracheal Anastomosis Protection: Tracheal Retention Sutures.

    Science.gov (United States)

    Karapolat, Sami; Turkyilmaz, Atila; Seyis, Kubra Nur; Tekinbas, Celal

    2018-04-01

    Fixation of the chin to the anterior chest wall is the most commonly used method of reducing anastomotic tension following a segmental resection of the trachea and reconstruction with primary anastomosis. However, the sutures required for this method may lead to various organic and psychological problems. In five patients who underwent tracheal resection and primary anastomosis, retention sutures were placed on the proximal and distal-lateral edges of the anastomotic line rather than placing a Guardian chin stitch. All patients were mobilised in the early postoperative period and were able to perform their routine daily activities without restrictions. During their average 14.4 months of follow-up, no complications were found in their anastomotic lines during their clinical, radiological, and bronchoscopic assessments. The placement of tracheal retention sutures proved an inexpensive and reliable method to reduce anastomotic tension without additional surgical burden, and was effective in terms of patient comfort. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  10. Traction suture modification to tongue-in-groove caudal septoplasty.

    Science.gov (United States)

    Indeyeva, Y A; Lee, T S; Gordin, E; Chan, D; Ducic, Y

    2018-02-01

    Caudal septal deviation leads to unfavorable esthetic as well as functional effects on the nasal airway. A modification to the tongue-in-groove (TIG) technique to correct these caudal septal deformities is described. With placement of a temporary suspension suture to the caudal septum, manual traction is applied, assuring that the caudal septum remains in the midline position while it is being secured with multiple through-and-through, trans-columellar and trans-septal sutures. From 2003 to 2016, 148 patients underwent endonasal septoplasty using this modified technique, with excellent functional and cosmetic outcomes and a revision rate of 1.4%. This modified TIG technique replaces the periosteal suture that secures the caudal septum to the midline nasal crest in the original TIG technique. This simplifies the procedure and minimizes the risk of securing the caudal septum off-midline when used in endonasal septoplasty. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    Directory of Open Access Journals (Sweden)

    Jeroni Nadal

    2015-01-01

    Full Text Available Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p=0.015 at 1 month, which persisted to 12 months (0.18 ± 0.60. Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%, vitreous hemorrhage in 2 eyes (8%, transient hypotony in 2 eyes (8%, and cystic macular edema in 1 eye (4%. No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  12. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach.

    Science.gov (United States)

    Nadal, Jeroni; Kudsieh, Bachar; Casaroli-Marano, Ricardo P

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA) LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p = 0.015) at 1 month, which persisted to 12 months (0.18 ± 0.60). Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%), vitreous hemorrhage in 2 eyes (8%), transient hypotony in 2 eyes (8%), and cystic macular edema in 1 eye (4%). No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  13. Central posterior capsule pigmentation in a patient with pigment dispersion and previous ocular trauma: a case report.

    Science.gov (United States)

    Al-Mezaine, Hani S

    2010-01-01

    We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg's spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger's from the posterior chamber.

  14. Central posterior capsule pigmentation in a patient with pigment dispersion and previous ocular trauma: A case report

    Directory of Open Access Journals (Sweden)

    Al-Mezaine Hani

    2010-01-01

    Full Text Available We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg′s spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger′s from the posterior chamber.

  15. Diogene pictorial drift chamber

    International Nuclear Information System (INIS)

    Gosset, J.

    1984-01-01

    A pictorial drift chamber, called DIOGENE, has been installed at Saturne in order to study central collisions of high energy heavy ions. It has been adapted from the JADE internal detector, with two major differences to be taken into account. First, the center-of-mass of these collisions is not identical to the laboratory reference frame. Second, the energy loss and the momentum ranges of the particles to be detected are different from the ones in JADE. It was also tried to keep the cost as small as possible, hence the choice of minimum size and minimum number of sensitive wires. Moreover the wire planes are shifted from the beam axis: this trick helps very much to quickly reject the bad tracks caused by the ambiguity of measuring drift distances (positive or negative) through times (always positive)

  16. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  17. Simulation of chamber experiments

    International Nuclear Information System (INIS)

    Ivanov, V.G.

    1981-01-01

    The description of the system of computer simulation of experiments conducted by means of track detectors with film data output is given. Considered is the principle of organization of computer model of the chamber experiment comprising the following stages: generation of events, generation of measurements, ge-- neration of scanning results, generation of distorbions, generated data calibration, filtration, events reconstruction, kinematic identification, total results tape formation, analysis of the results. Generation programs are formed as special RAM-files, where the RAM-file is the text of the program written in FORTRAN and divided into structural elements. All the programs are a ''part of the ''Hydra'' system. The system possibilities are considered on the base of the CDSC-6500 computer. The five-beam event generation, creation data structure for identification and calculation by the kinematic program take about 1s of CDC-6500 computer time [ru

  18. Nucleation in bubble chambers

    International Nuclear Information System (INIS)

    Harigel, G.G.

    1988-01-01

    Various sources and mechanisms for bubble formation in superheated liquids are discussed. Bubble chambers can be filled with a great variety of liquids, such as e.g. the cryogenic liquids hydrogen, deuterium, neon, neon/hydrogen mixtures, argon, nitrogen, argon/nitrogen mixtures, or the warm liquids propane and various Freon like Freon-13B1. The superheated state is normally achieved by a rapid movement of an expansion piston or membrane, but can also be produced by standing ultrasonic waves, shock waves, or putting liquids under tension. Bubble formation can be initiated by ionizing particles, by intense (laser) light, or on rough surfaces. The creation of embryonic bubbles is not completely understood, but the macroscopic growth and condensation can be calculated, allowing to estimate the dynamic heat load [fr

  19. Tissue reactions of abdominal integuments to surgical sutures in sonography

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2014-03-01

    Full Text Available Classical abdominal surgeries usually require long incisions of the abdominal integuments followed by tight closure with adequate suturing material. Nonabsorbable sutures may cause various reactions, including granuloma reactions, both sterile and inflammatory. The aim of the study was to analyze prospective ultrasound examinations of the abdominal integuments in order to detect tissue reactions to surgical sutures. Material and methods: For 10 years, ultrasound examinations of the abdominal integuments involved the assessment of surgical scars in all patients who underwent open or closed surgeries for various reasons (in total 2254 patients. Ultrasound examinations were performed only with the use of linear probes with the frequency ranging from 7 to 12 MHz. Each scar in the abdominal integuments was scanned in at least two planes. When a lesion was detected, the image was enlarged and the transducer was rotated by approximately 180° in order to capture the dimensions of the granuloma and the most characteristic image of the suture. Moreover, vascularization of the lesion was also assessed with the use of color Doppler mode set to detect the lowest flows. Results: All granulomas (19 lesions, two in one patient created hypoechoic oval or round nodules, were relatively well-circumscribed and their size ranged from 8 × 4 mm to 40 × 14 mm. In the center of the lesion, it was possible to notice a thread that was coiled to various degrees and presented itself as a double, curved hyperechoic line. In 9 out of 19 granulomas, slight peripheral vascularization was observed. The substantial majority of the lesions (n = 15 were in contact with the fascia. In seven patients, compression with the transducer induced known local pain (n = 4 or intensified pain that had already been present (n = 3; all of these granulomas infiltrated the fascia and showed slight peripheral vascularization. Cutaneous fistulae developed in two patients with purulent

  20. Laser tissue welding in genitourinary reconstructive surgery: assessment of optimal suture materials.

    Science.gov (United States)

    Poppas, D P; Klioze, S D; Uzzo, R G; Schlossberg, S M

    1995-02-01

    Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P welding appears to be between 60 degrees and 80 degrees C. Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.

  1. Evaluation of a novel suture material for closure of intestinal anastomoses in canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2012-11-01

    To compare leakage and maximum intraluminal pressures for a novel suture material with pressures for comparable suture material when used in closure of intestinal anastomoses in canine cadavers. Healthy intestines from cadavers of dogs euthanized for reasons unrelated to the study. 18 anastomoses were performed on intestinal sections within 72 hours after dogs were euthanized and intestinal samples collected. Anastomoses were performed with a simple continuous suture pattern. Leakage and maximum intraluminal pressures were measured and recorded for 6 control segments and 18 anastomosed sections. A barbed glycomer 631 suture (size 4-0 United States Pharmacopeia [USP]) was compared with glycomer 631 sutures (sizes 3-0 and 4-0 USP). Results for leakage and maximum intraluminal pressures were compared via an ANOVA. The barbed glycomer 631 suture material leaked at a significantly higher pressure than did the comparable glycomer 631 suture materials. Maximum intraluminal pressures were not significantly different among the suture materials. Barbed glycomer 631 4-0 USP suture material was as effective as glycomer 631 suture materials and may be a safe alternative for use in closure of enterectomies in dogs.

  2. Skull morphometry and vault sutures of Myrmecophaga tridactyla and Tamandua tetradactyla

    Directory of Open Access Journals (Sweden)

    Camila M. de S. Hossotani

    2017-10-01

    Full Text Available ABSTRACT This study aimed to examine the relationship between skull size and the level of cranial vault suture closure. A total of 50 Myrmecophaga tridactyla Linnaeus, 1758 and 178 Tamandua tetradactyla Linnaeus, 1758 skulls were analyzed in relation to 18 skull dimensions. The skulls were grouped into three levels of suture closure: no sutures closed (level 0, one or all the fallowing sutures closed: interfrontalis, sagitalis and coronalis (level 1 and all sutures closed (level 2. The results indicated that among the 18 variables measured, 17 showed significant differences (p ≤ 0.01 between level 0 and level 1 skulls of T. tetradactyla; as well as between level 0 and level 1, and level 0 and level 2 skulls of M. tridactyla. M. tridactyla level 1 and level 2 had no significant difference among any of the 18 dimensions. The foramen magnum height in both species showed no significant difference (p > 0.05 among any suture categories. In principle, suture closure level and cranial dimensions are related. The specimens with larger cranial dimensions showed greater number of cranial vault sutures closed for both species of anteaters. Tamandua tetradactyla and M. tridactyla specimens with none of the cranial vault suture closed have a foramen magnum height similar to those with cranial vault suture closed.

  3. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  4. Glue versus suture for mesh fixation in inguinal hernia repair.

    Science.gov (United States)

    Chandrasekar, Shruthi; Jeyakumar, S; Ganapathy, Tharun

    2018-03-22

    Inguinal hernia is one of the most common surgical problem presenting to the surgical OPD. Surgery is the mainstay of treatment for inguinal hernia today. Surgery for inguinal hernia has undergone a great evolution over a period of several centuries. Lichenstein's tension free hernioplasty is the one of the first surgeries taught to a surgical resident. The main aim of surgeries in this era is to give the best possible results with the least possible pain, scar and time. This has given rise to so many modifications to the classical Lichenstein's procedure and also to laparoscopic hernioplasty. Pain after inguinal hernia surgery is found to be debilitating and altering the quality of life in several patients, which has been attributed to the traumatic fixation of the mesh with sutures. This has paved way to the development of various atraumatic methods of fixation, tissue glue is one such development. Hence this study, to compare traumatic and atraumatic methods of mesh fixation in inguinal hernia repair. The aim of this study was to compare suture fixation versus tissue glue fixation of the mesh in inguinal hernia repair. Primary objective was to compare the immediate and chronic post-operative pain. Secondary objective was to compare the time taken for the procedure by the two methods in use and also to compare the presence of any complications. and methodology: This study was done in the General Surgery department of XXX hospital, medical college and research centre, kattangulathur after Ethics committee clearance. It is a single blinded study. The study was done on 51 patients consenting for the study and meeting the inclusion criterias from the period of March 2016 to August 2017 out of which 26 were selected for glue mesh fixation and 25 for suture mesh fixation according to simple randomization. The suture group patients underwent classical Lichenstein's tension free hernioplasty and the glue group underwent Lichenstein's hernioplasty with glue where dots of

  5. Visual attention in posterior stroke

    DEFF Research Database (Denmark)

    Fabricius, Charlotte; Petersen, Anders; Iversen, Helle K

    Objective: Impaired visual attention is common following strokes in the territory of the middle cerebral artery, particularly in the right hemisphere. However, attentional effects of more posterior lesions are less clear. The aim of this study was to characterize visual processing speed...... and apprehension span following posterior cerebral artery (PCA) stroke. We also relate these attentional parameters to visual word recognition, as previous studies have suggested that reduced visual speed and span may explain pure alexia. Methods: Nine patients with MR-verified focal lesions in the PCA......-territory (four left PCA; four right PCA; one bilateral, all >1 year post stroke) were compared to 25 controls using single case statistics. Visual attention was characterized by a whole report paradigm allowing for hemifield-specific speed and span measurements. We also characterized visual field defects...

  6. Classification of posterior vitreous detachment

    OpenAIRE

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2013-01-01

    Akihiro Kakehashi,1 Mikiko Takezawa,1 Jun Akiba21Department of Ophthalmology, Jichi Medical University, Saitama Medical Center, Saitama, 2Kanjodori Eye Clinic, Asahikawa, JapanAbstract: Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography...

  7. Bundles of spider silk, braided into sutures, resist basic cyclic tests: potential use for flexor tendon repair.

    Directory of Open Access Journals (Sweden)

    Kathleen Hennecke

    Full Text Available Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.

  8. Traumatic posterior fossa epidural hematoma

    International Nuclear Information System (INIS)

    Ikeda, Yukio; Nakazawa, Shozo; Yamakawa, Kazuomi; Kobayashi, Shiro; Tsuji, Yukihide

    1981-01-01

    In this paper three acute cases and two subacute cases are reported. CT findings in acute cases show two different types. ''Type I'' shows crescent or lenticular high density area which is not enhanced after contrast infusion. ''Type II'' shows lenticular low density area with membranous high density region in its medial side after contrast infusion. In subacute cases plain CT scan shows lenticular iso or low density area with membranous high density region in its medial side. Forty five cases of posterior fossa epidural hematoma in the review of literature of this country are discussed. Disturbances of the consciousness are the most predominant symptoms in acute cases, while in subacute cases cerebellar signs, vomiting, headache and choked disc are noted. Angiographical examinations may not always be valuable in collecting the direct information of the existence of the epidural hematoma. Liquor cavity in the posterior fossa which is thought to serve as a buffer action of hematoma is about 20 ml, so we discuss about the volume of hematoma, especially of 20 ml, associated with clinical course and prognosis. Volume of epidural hematoma is one of the most important factors affecting clinical course and prognosis. In summary of these our experiences, we again emphasize the value of CT scan as the rapid, noninvasive, accurate radiological examination in the diagnosis of traumatic posterior fossa epidural hematoma. (author)

  9. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  10. A simple suture-retrieval device for the placement of u-stitches during laparoscopic gastrostomy.

    Science.gov (United States)

    Mattei, Peter

    2009-02-01

    During minimally invasive operations, it is sometimes necessary to retrieve the end of a suture or a suture needle and bring it out through the abdominal wall. Using a standard needle and a length of suture, we have developed a simple device that allows the retrieval of a suture end during minimally invasive operations that require the placement of U-or stay stitches. The author has used the device described during more than 100 laparoscopic gastrostomy placement procedures and other operations involving the placement of U- or stay stitches with excellent results and no complications. Using a beveled hollow-bore needle and a loop of polypropylene suture, one can construct a simple device that allows the retrieval of a suture from within a body cavity during minimally invasive surgery, making the placement of U- and stay stitches easier and more precise.

  11. The little holographic bubble chambers

    International Nuclear Information System (INIS)

    Herve, A.

    1983-01-01

    The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr

  12. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  13. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  14. A simple method to take urethral sutures for neobladder reconstruction and radical prostatectomy

    Directory of Open Access Journals (Sweden)

    B Satheesan

    2007-01-01

    Full Text Available For the reconstruction of urethra-vesical anastamosis after radical prostatectomy and for neobladder reconstruction, taking adequate sutures to include the urethral mucosa is vital. Due to the retraction of the urethra and unfriendly pelvis, the process of taking satisfactory urethral sutures may be laborious. Here, we describe a simple method by which we could overcome similar technical problems during surgery using Foley catheter as the guide for the suture.

  15. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    Science.gov (United States)

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  16. Surgical sutures filled with adipose-derived stem cells promote wound healing.

    Directory of Open Access Journals (Sweden)

    Ann Katharin Reckhenrich

    Full Text Available Delayed wound healing and scar formation are among the most frequent complications after surgical interventions. Although biodegradable surgical sutures present an excellent drug delivery opportunity, their primary function is tissue fixation. Mesenchymal stem cells (MSC act as trophic mediators and are successful in activating biomaterials. Here biodegradable sutures were filled with adipose-derived mesenchymal stem cells (ASC to provide a pro-regenerative environment at the injured site. Results showed that after filling, ASCs attach to the suture material, distribute equally throughout the filaments, and remain viable in the suture. Among a broad panel of cytokines, cell-filled sutures constantly release vascular endothelial growth factor to supernatants. Such conditioned media was evaluated in an in vitro wound healing assay and showed a significant decrease in the open wound area compared to controls. After suturing in an ex vivo wound model, cells remained in the suture and maintained their metabolic activity. Furthermore, cell-filled sutures can be cryopreserved without losing their viability. This study presents an innovative approach to equip surgical sutures with pro-regenerative features and allows the treatment and fixation of wounds in one step, therefore representing a promising tool to promote wound healing after injury.

  17. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Sutker, Michael J

    2009-09-01

    To evaluate the biomechanical characteristics of current meniscal repair techniques containing ultra high-molecular weight polyethylene (UHMWPE) suture with and without cyclic loading. Vertical longitudinal cuts made in porcine menisci were secured with a single repair device. Noncycled and cycled (500 cycles) biomechanical tests were performed on the following groups: group 1, No. 2-0 Mersilene vertical suture (Ethicon, Somerville, NJ); group 2, No. 2-0 Orthocord vertical suture (DePuy Mitek, Westwood, MA); group 3, No. 0 Ultrabraid vertical suture (Smith & Nephew Endoscopy, Andover, MA); group 4, No. 2-0 FiberWire vertical suture (Arthrex, Naples, FL); group 5, vertically oriented mattress suture by use of an Ultra FasT-Fix device (Smith & Nephew Endoscopy) with No. 0 Ultrabraid; group 6, vertically oriented mattress suture by use of a RapidLoc A2 device (DePuy Mitek) with No. 2-0 Orthocord suture; group 7, vertically oriented stitch by use of a MaxFire device with MaxBraid PE suture (Biomet Sports Medicine, Warsaw, IN); and group 8, an obliquely oriented stitch of No. 0 UHMWPE suture inserted by use of a CrossFix device (Cayenne Medical, Scottsdale, AZ). Endpoints were failure loads, failure modes, stiffness, and cyclic displacement. Mean single-pull loads were calculated for Ultra FasT-Fix (121 N), FiberWire (110 N), MaxFire (130 N), Mersilene (84 N), Orthocord (124 N), RapidLoc A2 (86 N), CrossFix (77 N), and Ultrabraid (109 N). After 500 cyclic loads, the Orthocord (222 N) repair was stronger than the others: Ultra FasT-Fix (110 N), FiberWire (117 N), MaxFire (132 N), Mersilene (89 N), RapidLoc A2 (108 N), CrossFix (95 N), and Ultrabraid (126 N) (P Fix, RapidLoc A2, and MaxFire) were comparable to the isolated UHMWPE-containing suture repairs on single-failure load testing. UHMWPE-containing suture repairs are stronger than braided polyester suture repairs, but pure UHMWPE suture (Ultrabraid) elongated more during cycling. Orthocord suture is significantly

  18. Rhinoplasty: a simplified, three-stitch, open tip suture technique. Part I: primary rhinoplasty.

    Science.gov (United States)

    Daniel, R K

    1999-04-01

    Tip suture techniques offer a reliable and dramatic method of tip modification without needing to interrupt the alar rim strip or add tip grafts. The present simplified three-stitch technique consists of the following: (1) a strut suture to fix the columella strut between the crura, (2) bilateral domal creation sutures to create tip definition, and (3) a domal equalization suture to narrow and align the domes. If required, columella septal sutures can be added; either a dorsal rotational suture or a transfixion projection suture can be used. This simplified method represents a refinement based on more than 13 years of experience with tip suture techniques. It does not require a complex operative sequence or specialized sutures. Primary indications are moderate tip deformities of inadequate definition and excessive width and certain specific tip deformities, including the parenthesis tip and nostril/tip disproportion. The primary contraindications are for patients with minor tip deformities that are best done through a closed approach and those with severe tip deformities requiring an open structure graft. The technique is simple, efficacious, and easily learned.

  19. Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).

    Science.gov (United States)

    Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao

    2008-07-01

    The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.

  20. Elasticity and breaking strength of synthetic suture materials incubated in various equine physiological and pathological solutions.

    Science.gov (United States)

    Kearney, C M; Buckley, C T; Jenner, F; Moissonnier, P; Brama, P A J

    2014-07-01

    Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. In vitro material testing. Suture materials were exposed in vitro to physiological fluid, followed by biomechanical analysis. Three absorbable suture materials, glycolide/lactide copolymer, polyglactin 910 and polydioxanone were incubated at 37°C for 7, 14 or 28 days in phosphate-buffered saline, equine serum, equine urine and equine peritoneal fluid from an animal with peritonitis. Five strands of each suture material type were tested to failure in a materials testing machine for each time point and each incubation medium. Yield strength, strain and Young's modulus were calculated, analysed and reported. For all suture types, the incubation time had a significant effect on yield strength, percentage elongation and Young's modulus in all culture media (Ptype was also shown significantly to influence changes in each of yield strength, percentage elongation and Young's modulus in all culture media (Ptype of fluid have significant effects on the biomechanical properties of various suture materials. These findings are important for evidence-based selection of suture material in clinical cases. © 2013 EVJ Ltd.

  1. Extrusion of bone anchor suture following flexor digitorum profundus tendon avulsion injury repair.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2011-09-01

    Flexor digitorum profundus (FDP) zone I tendon avulsion injury is traditionally repaired with a pullout suture technique. More recently, bone anchor sutures have been used as a viable alternative and have largely replaced areas in hand surgery where pullout suture technique was once required. To date, there have been very few complications reported related to bone anchor suture use in FDP tendon reattachment to the bone. We report a very unusual case of extrusion of bone anchor through the nailbed, 6 years after zone I FDP tendon avulsion injury repair and a brief review of literature.

  2. Effects of diode laser welding with dye-enhanced glue on tensile strength of sutures commonly used in urology.

    Science.gov (United States)

    Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W

    1996-01-01

    Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.

  3. Hematomas na fossa craniana posterior

    Directory of Open Access Journals (Sweden)

    Mário S. Cademartori

    1969-09-01

    Full Text Available São relatados 6 casos de hematomas sub-tentorias (um de hematoma subdural crônico, quatro de hematomas intra-cerebelares, um de hematoma extra-dural. Salientando a pequena freqüência dos hematomas da fossa craniana posterior, o autor mostra a necessidade de vários exames complementares para o diagnóstico exato, indispensável para a aplicação de terapêutica cirúrgica adequada.

  4. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  5. Pelletron general purpose scattering chamber

    International Nuclear Information System (INIS)

    Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh

    1993-01-01

    A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs

  6. Huge interparietal posterior fontanel meningohydroencephalocele

    Directory of Open Access Journals (Sweden)

    Jorge Félix Companioni Rosildo

    2015-03-01

    Full Text Available Congenital encephalocele is a neural tube defect characterized by a sac-like protrusion of the brain, meninges, and other intracranial structures through the skull, which is caused by an embryonic development abnormality. The most common location is at the occipital bone, and its incidence varies according to different world regions. We report a case of an 1-month and 7-day-old male child with a huge interparietal-posterior fontanel meningohydroencephalocele, a rare occurrence. Physical examination and volumetric computed tomography were diagnostic. The encephalocele was surgically resected. Intradural and extradural approaches were performed; the bone defect was not primarily closed. Two days after surgery, the patient developed hydrocephaly requiring ventriculoperitoneal shunting. The surgical treatment of the meningohydroencephalocele of the interparietal-posterior fontanel may be accompanied by technical challenges and followed by complications due to the presence of large blood vessels under the overlying skin. In these cases, huge sacs herniate through large bone defects including meninges, brain, and blood vessels. The latter present communication with the superior sagittal sinus and ventricular system. A favorable surgical outcome generally follows an accurate strategy taking into account individual features of the lesion.

  7. Orthodontic treatment for posterior crossbites.

    Science.gov (United States)

    Agostino, Paola; Ugolini, Alessandro; Signori, Alessio; Silvestrini-Biavati, Armando; Harrison, Jayne E; Riley, Philip

    2014-08-08

    A posterior crossbite occurs when the top back teeth bite inside the bottom back teeth. When it affects one side of the mouth, the lower jaw may have to move to one side to allow the back teeth to meet together. Several treatments have been recommended to correct this problem. Some treatments widen the upper teeth while others are directed at treating the cause of the posterior crossbite (e.g. breathing problems or sucking habits). Most treatments have been used at each stage of dental development. This is an update of a Cochrane review first published in 2001. To assess the effects of orthodontic treatment for posterior crossbites. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 21 January 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 1), MEDLINE via OVID (1946 to 21 January 2014), and EMBASE via OVID (1980 to 21 January 2014). We searched the US National Institutes of Health Trials Register and the World Health Organization (WHO) Clinical Trials Registry Platform for ongoing trials. We placed no restrictions on the language or date of publication when searching the electronic databases. Randomised controlled trials (RCTs) of orthodontic treatment for posterior crossbites in children and adults. Two review authors, independently and in duplicate, screened the results of the electronic searches, and extracted data and assessed the risk of bias of the included studies. We attempted to contact the first named authors of the included studies for missing data and for clarification. We used risk ratios (RR) and 95% confidence intervals (CIs) to summarise dichotomous (event) data, and mean differences (MD) with 95% CIs to summarise continuous data. We performed meta-analyses using fixed-effect models (we would have used random-effects models if we had included four or more studies in a meta-analysis) when comparisons and outcomes were sufficiently similar. We

  8. Assessing suturing techniques using a virtual reality surgical simulator.

    Science.gov (United States)

    Kazemi, Hamed; Rappel, James K; Poston, Timothy; Hai Lim, Beng; Burdet, Etienne; Leong Teo, Chee

    2010-09-01

    Advantages of virtual-reality simulators surgical skill assessment and training include more training time, no risk to patient, repeatable difficulty level, reliable feedback, without the resource demands, and ethical issues of animal-based training. We tested this for a key subtask and showed a strong link between skill in the simulator and in reality. Suturing performance was assessed for four groups of participants, including experienced surgeons and naive subjects, on a custom-made virtual-reality simulator. Each subject tried the experiment 30 times using five different types of needles to perform a standardized suture placement task. Traditional metrics of performance as well as new metrics enabled by our system were proposed, and the data indicate difference between trained and untrained performance. In all traditional parameters such as time, number of attempts, and motion quantity, the medical surgeons outperformed the other three groups, though differences were not significant. However, motion smoothness, penetration and exit angles, tear size areas, and orientation change were statistically significant in the trained group when compared with untrained group. This suggests that these parameters can be used in virtual microsurgery training.

  9. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  10. Glaucoma anterior chamber morphometry based on optical Scheimpflug images.

    Science.gov (United States)

    Alonso, Ruiz Simonato; Ambrósio Junior, Renato; Paranhos Junior, Augusto; Sakata, Lisandro Massanori; Ventura, Marcelo Palis

    2010-01-01

    To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.

  11. Multiple Coronary Chamber Microfistulas or Persistent Thebesian Vessels?

    Directory of Open Access Journals (Sweden)

    Cernica Daniel

    2017-09-01

    Full Text Available Coronary fistulas are rare, not gender-specific congenital conditions, consisting of communications between the coronary arteries and either another coronary vessel or a cardiac chamber. In contrast to large fistulas, small fistulas, named “minimae cordis veneae” or the Thebesius venous system, are draining into heart chambers and form a vascular network in the cardiac lumen. In this article, we present the case of a 72-year-old female with a significant history of cardiovascular disease, admitted to our clinic because of rest dyspnea, fatigue, and minimal chest pain. The 12-lead electrocardiogram showed a trifascicular block (a second-degree atrioventricular block Mobitz II, associated with a right bundle branch block and left anterior fascicle block and negative T waves in DII, DIII, aVF, V4–V6 leads. An invasive coronary angiography was performed, which revealed no significant atherosclerotic lesions. However, a persistent capillary blush was present at the apex site of the left ventricular chamber, draining from the distal segments of both the anterior descending coronary artery and the posterior interventricular coronary artery. The intramural vascular network generating a left ventricle angiogram image of this kind was suggestive for persistent Thebesian vessels connecting the two coronaries with the left ventricular chamber.

  12. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  13. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  14. A small flat fission chamber

    International Nuclear Information System (INIS)

    Li Yijun; Wang Dalun; Chen Suhe

    1999-01-01

    With fission materials of depleted uranium, natural uranium, enriched uranium, 239 Pu, and 237 Np, the authors have designed and made a series of small flat fission chamber. The authors narrated the construction of the fission chamber and its technological process of manufacture, and furthermore, the authors have measured and discussed the follow correct factor, self-absorption, boundary effect, threshold loss factor, bottom scatter and or so

  15. Advances on fission chamber modelling

    International Nuclear Information System (INIS)

    Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob

    2013-06-01

    In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the

  16. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  17. The OPAL vertex drift chamber

    International Nuclear Information System (INIS)

    Carter, J.R.; Elcombe, P.A.; Hill, J.C.; Roach, C.M.; Armitage, J.C.; Carnegie, R.K.; Estabrooks, P.; Hemingway, R.; Karlen, D.; McPherson, A.; Pinfold, J.; Roney, J.M.; Routenburg, P.; Waterhouse, J.; Hargrove, C.K.; Klem, D.; Oakham, F.G.; Carter, A.A.; Jones, R.W.L.; Lasota, M.M.B.; Lloyd, S.L.; Pritchard, T.W.; Wyatt, T.R.

    1990-01-01

    A high precision vertex drift chamber has been installed in the OPAL experiment at LEP. The design of the chamber and the associated readout electronics is described. The performance of the system has been studied using cosmic ray muons and the results of these studies are presented. A space resolution of 50 μm in the drift direction is obtained using the OPAL central detector gas mixture at 4 bar. (orig.)

  18. Biomechanical comparison of an all-soft suture anchor with a modified Broström-Gould suture repair for lateral ligament reconstruction.

    Science.gov (United States)

    Brown, Christopher A; Hurwit, Daniel; Behn, Anthony; Hunt, Kenneth J

    2014-02-01

    Anatomic repair is indicated for patients who have recurrent lateral ankle instability despite nonoperative measures. There is no difference in repair stiffness, failure torque, or failure angle between specimens repaired with all-soft suture anchors versus the modified Broström-Gould technique with sutures only. Controlled laboratory study. In 10 matched pairs of human cadaveric ankles, the anterior talofibular ligament (ATFL) was incised from its origin on the fibula. After randomization, 1 ankle was repaired to its anatomic insertion using two 1.4-mm JuggerKnot all-soft suture anchors; the other ankle was repaired with a modified Broström-Gould technique using 2-0 FiberWire. All were augmented using the inferior extensor retinaculum. All ankles were mounted to the testing machine in 20° of plantar flexion and 15° of internal rotation and loaded to failure after the repair. Stiffness, failure torque, and failure angle were recorded and compared using a paired Student t test with a significance level set at P anchors pulled out of bone. The primary mode of failure was pulling through the ATFL tissue. There was no statistical difference in strength or stiffness between a 1.4-mm all-soft suture anchor and a modified Broström-Gould repair with 2-0 FiberWire. The primary mode of failure was at the tissue level rather than knot failure or anchor pullout. The particular implant choice (suture only, tunnel, anchor) in repairing the lateral ligament complex may not be as important as the time to biological healing. The suture-only construct as described in the Broström-Gould repair was as strong as all-soft suture anchors, and the majority of the ankles failed at the tissue level. For those surgeons whose preference is to use anchor repair, this novel all-soft suture anchor may be an alternative to other larger anchors, as none failed by pullout.

  19. PEP quark search proportional chambers

    Energy Technology Data Exchange (ETDEWEB)

    Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)

    1981-04-01

    Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.

  20. A case of laparoscopy-assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Tomoatsu Jimi

    Full Text Available Introduction: Vaginal cuff dehiscence after hysterectomy is a rare complication and occurs in less than 1% of patients. It can present with serious complications, such as bowel evisceration and peritonitis. Presentation of case: A 51-year-old multigravida Korean woman underwent total laparoscopic hysterectomy for leiomyoma. Six months later, she reported lower abdominal pain and vaginal bleeding. Physical examination revealed rebound tenderness in the lower abdomen, and pelvic examination showed a small amount of vaginal bleeding with an evisceration of the small intestine through the vagina that exhibited healthy peristalsis. The eviscerated bowel, which seemed to be a part of the ileum, was carefully manually reduced transvaginally into the abdominal cavity. Laparoscopic observation revealed adhesions between the omentum, small intestine, and the peritoneum. Specifically, the small intestine was adhered around the vaginal cuff. An abdominal abscess was found in the left lower abdominal cavity. An adhesiotomy was performed and the abdominal abscess was removed and irrigated. Complete separation of the anterior and posterior vaginal cuff edges was obtained. The vaginal cuff was closed with interrupted 0-polydioxanone absorbable sutures without bowel injury. A 6-month follow-up examination revealed complete healing of the vaginal cuff. Discussion: In this case, we were able to make use of both laparoscopic and transvaginal methods to perform a successful repair with a minimally invasive and safe technique. Conclusion: Laparoscopically assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy was found to be effective, safe, and minimally invasive. Keywords: Vaginal cuff dehiscence, Vaginal cuff repair, Vaginal cuff evisceration, Laparoscopic hysterectomy, Complication

  1. Genipin crosslinker releasing sutures for improving the mechanical/repair strength of damaged connective tissue.

    Science.gov (United States)

    Sundararaj, Sharath; Slusarewicz, Paul; Brown, Matt; Hedman, Thomas

    2017-11-01

    The most common mode of surgical repair of ruptured tendons and ligaments involves the use of sutures for reattachment. However, there is a high incidence of rerupture and repair failure due to pulling out of the suture material from the damaged connective tissue. The main goal of this research was to achieve a localized delivery of crosslinking agent genipin (GP) from rapid-release biodegradable coatings on sutures, for strengthening the repair of ruptured connective tissue. Our hypothesis is that GP released from the suture coating will lead to exogenous crosslinking of native connective tissue resulting in beneficial effects on clinically relevant mechanical parameters such as tear resistance, tissue strength, and energy required to rupture the tissue (toughness). Sutures were successfully coated with a biodegradable polymer layer loaded with the crosslinking agent genipin, without compromising the mechanical properties of the suture. The rapid-release of genipin was achieved under both in vitro and ex vivo conditions. Exogenous crosslinking using these genipin releasing sutures was demonstrated using equine tendons. The tendons treated with genipin releasing sutures showed significant improvement in failure load, energy required for pull-out failure, and stiffness. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2199-2205, 2017. © 2016 Wiley Periodicals, Inc.

  2. Critical Anatomy Relative to the Sacral Suture: A Postoperative Imaging Study After Robotic Sacrocolpopexy.

    Science.gov (United States)

    Crisp, Catrina C; Herfel, Charles V; Pauls, Rachel N; Westermann, Lauren B; Kleeman, Steven D

    2016-01-01

    This study aimed to characterize pertinent anatomy relative to the sacral suture placed at time of robotic sacrocolpopexy using postoperative computed tomography and magnetic resonance imaging. A vascular clip was placed at the base of the sacral suture at the time of robotic sacrocolpopexy. Six weeks postoperatively, subjects returned for a computed tomography scan and magnetic resonance imaging. Ten subjects completed the study. The middle sacral artery and vein coursed midline or to the left of midline in all the subjects. The left common iliac vein was an average of 26 mm from the sacral suture. To the right of the suture, the right common iliac artery was 18 mm away. Following the right common iliac artery to its bifurcation, the right internal iliac was on average 10 mm from the suture. The bifurcations of the inferior vena cava and the aorta were 33 mm and 54 mm further cephalad, respectively.The right ureter, on average, was 18 mm from the suture. The thickness of the anterior longitudinal ligament was 2 mm.The mean angle of descent of the sacrum was 70 degrees. Lastly, we found that 70% of the time, a vertebral body was directly below the suture; the disc was noted in 30%. We describe critical anatomy surrounding the sacral suture placed during robotic sacrocolpopexy. Proximity of both vascular and urologic structures within 10 to 18 mm, as well as anterior ligament thickness of only 2 mm highlights the importance of adequate exposure, careful dissection, and surgeon expertise.

  3. Early secondary suture versus healing by second intention of incisional abscesses

    DEFF Research Database (Denmark)

    Hermann, G G; Bagi, P; Christoffersen, I

    1988-01-01

    A controlled trial was set up to compare the treatment of wound abscesses, occurring after laparotomy, with either early secondary suture combined with cefuroxime and metronidazole given intravenously or by healing by second intention. The secondary suture was performed two days after wound...... drainage and resulted in a significant reduction (p less than 0.01) in healing time without complications. No reinfections occurred....

  4. Antibacterial-Coated Suture in Reducing Surgical Site Infection in Breast Surgery: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Enora Laas

    2012-01-01

    Full Text Available Background. To reduce the incidence of microbial colonization of suture material, Triclosan- (TC-coated suture materials have been developed. The aim of this study was to assess the incidence of suture-related complications (SRC in breast surgery with and without the use of TC-coated sutures. Methods. We performed a study on two consecutive periods: 92 patients underwent breast surgery with conventional sutures (Group 1 and 98 with TC-coated sutures (Group 2. We performed subgroups analyses and developed a model to predict SRC in Group 1 and tested its clinical efficacy in Group 2 using a nomogram-based approach. Results. The SRC rates were 13% in Group 1 and 8% in Group 2. We found that some subgroups may benefit from TC-coated sutures. The discrimination obtained from a logistic regression model developed in Group 1 and based on multifocality, age and axillary lymphadenectomy was 0.88 (95% CI 0.77–0.95 (. There was a significant difference in Group 2 between predicted probabilities and observed percentages (. The predicted and observed proportions of complications in the high-risk group were 38% and 13%, respectively. Conclusion. This study used individual predictions of SRC and showed that using TC-coated suture may prevent SRC. This was particularly significant in high-risk patients.

  5. Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine

    Science.gov (United States)

    Staton, Amy J.; Boyd, Christine B.

    2013-01-01

    This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…

  6. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    Science.gov (United States)

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or single-row constructs showed 5 mm of displacement after the first 100 cycles. The most common failure mode for both constructs was suture tearing through the tendon. Differences in cuff fixation influence rotational tendon movement and may influence postoperative healing. Stronger repair constructs still fail at the suture-tendon interface. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Comparison of clinical outcomes of multi-point umbrella suturing and single purse suturing with two-point traction after procedure for prolapse and hemorrhoids (PPH) surgery.

    Science.gov (United States)

    Jiang, Huiyong; Hao, Xiuyan; Xin, Ying; Pan, Youzhen

    2017-11-01

    To compare the clinical outcomes of multipoint umbrella suture and single-purse suture with two-point traction after procedure for prolapse and hemorrhoids surgery (PPH) for the treatment of mixed hemorrhoids. Ninety patients were randomly divided into a PPH plus single-purse suture group (Group A) and a PPH plus multipoint umbrella suture (Group B). All operations were performed by an experienced surgeon. Operation time, width of the specimen, hemorrhoids retraction extent, postoperative pain, postoperative bleeding, and length of hospitalization were recorded and compared. Statistical analysis was conducted by t-test and χ2 test. There were no significant differences in sex, age, course of disease, and degree of prolapse of hemorrhoids between the two groups. The operative time in Group A was significantly shorter than that in Group B (P hemorrhoid core retraction were significantly lower in Group B (P  0.05 for all comparisons) was observed. The multipoint umbrella suture showed better clinical outcomes because of its targeted suture according to the extent of hemorrhoid prolapse. Copyright © 2017. Published by Elsevier Ltd.

  8. SR and LR Union Suture for the Treatment of Myopic Strabismus Fixus: Is Scleral Fixation Necessary?

    Directory of Open Access Journals (Sweden)

    Carol P. S. Lam

    2015-01-01

    Full Text Available Purpose. To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. Methods. Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR and lateral rectus (LR with or without scleral fixation, and follow-up longer than 6 months at Hong Kong Eye Hospital from 2006 to 2013. Surgical techniques and outcomes in terms of ocular alignment are analyzed. Results. There is significant overall improvement both in postoperative angle of esodeviation (P0.05. Conclusions. Union suture of SR and LR is an effective procedure in correcting myopic strabismus fixus. Fixation of the union suture to the sclera does not improve surgical outcome.

  9. Sutures coated with antiseptic pomade to prevent bacterial colonization: a randomized clinical trial.

    Science.gov (United States)

    Cruz, Fernando; Leite, Fabiola; Cruz, Gustavo; Cruz, Silvia; Reis, Juarez; Pierce, Matthew; Cruz, Mauro

    2013-08-01

    The aim of this study was to assess if an antiseptic pomade could reduce the bacterial colonization on multifilament sutures. A randomized clinical trial was conducted with 40 volunteer patients of both sexes aged 18-70, randomly separated into experimental (n = 20) and control (n = 20) groups. The experimental group received pomade-coated sutures (iodoform + calendula) and the control group uncoated sutures. Two millimeters of the suture was harvested from each patient from the 1st to the 15th postoperative day. The bacteria that had adhered to them were cultured. The number of colony-forming units per milliliter (CFU/mL) was determined and the groups were compared using the Mann-Whitney statistical test (P antiseptic pomade was effective in reducing bacterial colonization on silk braided sutures. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Nonabsorbable-Suture-Induced Osteomyelitis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cheng Hong Yeo

    2012-01-01

    Full Text Available We are reporting a case of nonabsorbable suture-induced osteomyelitis in patient who had an open rotator cuff repair with nonabsorbable Ethibond anchor suture. Patient in this case presented with very subtle clinical features of osteomyelitis of the left proximal humerus 15 years after initial rotator cuff repair surgery. Literature had shown that deep infection following rotator cuff repairs, although rare, can be easily missed and can cause severe complications. Absorbable suture had been demonstrated to be more superior, in terms of rate of deep infection, as compared to nonabsorbable suture when used in rotator cuff repair surgery. Both absorbable and nonabsorbable suture had been demonstrated to have similar mechanical properties by several different studies. The case demonstrated that initial presentation of deep infection can be subtle and easily missed by clinicians and leads to further complications.

  11. The primary factor for suture configuration at rotator cuff repair: Width of mattress or distance from tear edge

    Directory of Open Access Journals (Sweden)

    Onur Hapa

    2016-08-01

    Conclusion: Bite size from the edge of the tendon seems to be more important than the width of the mattress. The curve of the suture passing device may also have an effect on the strength of the suture tendon interface.

  12. BILATERAL SIMULTANEOUS ANTERIOR AND POSTERIOR LENTICONUS WITHOUT SYSTEMIC SIGNS

    Directory of Open Access Journals (Sweden)

    Hima Bindu

    2015-02-01

    Full Text Available A 21 year male came for eye checkup with a refractive error OD - 12.00 sph, - 2.25 @ 160° cyl and OS - 15.00 sph, - 2.50 @ 5°cyl and was referred to department of refractive surgery for opinion His BCVA in OD 6 / 18, OS 6/ 24. Slit lamp examination under dilation with phenylephrine plus tropic amide revealed the abnormal contour of the anterior and posterior lens capsule. Rest of the findings were normal with clear cornea, Von Herricks grade 3 deep anterior chamber, open angles in Gonioscopy. Retro illumination showed the typical’ oil droplet configuration’ in the lens. Retinal examination with the 90 D lens was otherwise normal except of the peculiar ‘OMEGA' shaped curving of the slit beam over the retina which occurred due the difference in the refractive power of the lens in the axial and paraxial zones of the lens

  13. Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study.

    Science.gov (United States)

    Gartsman, Gary M; Drake, Gregory; Edwards, T Bradley; Elkousy, Hussein A; Hammerman, Steven M; O'Connor, Daniel P; Press, Cyrus M

    2013-11-01

    The purpose of this study was to compare the structural outcomes of a single-row rotator cuff repair and double-row suture bridge fixation after arthroscopic repair of a full-thickness supraspinatus rotator cuff tear. We evaluated with diagnostic ultrasound a consecutive series of ninety shoulders in ninety patients with full-thickness supraspinatus tears at an average of 10 months (range, 6-12) after operation. A single surgeon at a single hospital performed the repairs. Inclusion criteria were full-thickness supraspinatus tears less than 25 mm in their anterior to posterior dimension. Exclusion criteria were prior operations on the shoulder, partial thickness tears, subscapularis tears, infraspinatus tears, combined supraspinatus and infraspinatus repairs and irreparable supraspinatus tears. Forty-three shoulders were repaired with single-row technique and 47 shoulders with double-row suture bridge technique. Postoperative rehabilitation was identical for both groups. Ultrasound criteria for healed repair included visualization of a tendon with normal thickness and length, and a negative compression test. Eighty-three patients were available for ultrasound examination (40 single-row and 43 suture-bridge). Thirty of 40 patients (75%) with single-row repair demonstrated a healed rotator cuff repair compared to 40/43 (93%) patients with suture-bridge repair (P = .024). Arthroscopic double-row suture bridge repair (transosseous equivalent) of an isolated supraspinatus rotator cuff tear resulted in a significantly higher tendon healing rate (as determined by ultrasound examination) when compared to arthroscopic single-row repair. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  14. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  15. Load response and gap formation in a single-row cruciate suture rotator cuff repair.

    Science.gov (United States)

    Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C

    2017-06-01

    Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.

  16. Pullout strength of cement-augmented and wide-suture transosseous fixation in the greater tuberosity.

    Science.gov (United States)

    Shi, Brendan Y; Diaz, Miguel; Belkoff, Stephen M; Srikumaran, Uma

    2017-12-01

    Obtaining strong fixation in low-density bone is increasingly critical in surgical repair of rotator cuff tears because of the aging population. To evaluate two new methods of improving pullout strength of transosseous rotator cuff repair in low-density bone, we analyzed the effects of 1) using 2-mm suture tape instead of no. 2 suture and 2) augmenting the lateral tunnel with cement. Eleven pairs of osteopenic or osteoporotic cadaveric humeri were identified by dual-energy x-ray absorptiometry. One bone tunnel and one suture were placed in the heads of 22 specimens. Five randomly selected pairs were repaired with no. 2 suture; the other six pairs were repaired with 2-mm suture tape. One side of each pair received lateral tunnel cement augmentation. Specimens were tested to suture pullout. Data were fitted to multivariate models that accounted for bone mineral density and other specimen characteristics. Two specimens were excluded because of knot-slipping during testing. Use of suture tape versus no. 2 suture conferred a 75-N increase (95% CI: 37, 113) in pullout strength (PCement augmentation conferred a 42-N improvement (95% CI: 10, 75; P=0.011). Other significant predictors of pullout strength were age, sex, and bone mineral density. We show two methods of improving the fixation strength of transosseous rotator cuff repairs in low-density bone: using 2-mm suture tape instead of no. 2 suture and augmenting the lateral tunnel with cement. These methods may improve the feasibility of transosseous repairs in an aging patient population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.

    Science.gov (United States)

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-09-01

    In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.

  18. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting.

    Science.gov (United States)

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting. A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. In both groups, the BCVA improved significantly ( P <0.001 for the modified round pattern group, P =0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased ( P <0.001 for both) and the ACA significantly increased ( P =0.001 for the modified round pattern group and P =0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  19. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting

    Directory of Open Access Journals (Sweden)

    Jin-Soo Kim

    2018-02-01

    Full Text Available AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG laser posterior capsulotomy with vitreous strand cutting METHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern. The best corrected visual acuity (BCVA, intraocular pressure (IOP, refractive error, endothelial cell count (ECC, anterior segment parameters, including anterior chamber depth (ACD and anterior chamber angle (ACA were measured before and 1mo after the laser posterior capsulotomy. RESULTS: In both groups, the BCVA improved significantly (P<0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group; the IOP and ECC did not significantly change. The ACD significantly decreased (P<0.001 for both and the ACA significantly increased (P=0.001 for the modified round pattern group and P=0.034 for the cruciate group. The extent of changes in these parameters was not significantly different between the groups. CONCLUSION: Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  20. The internalization of posterior subcapsular cataracts (PSCs) in Royal College of Surgeons (RCS) rats. II. The inter-relationship of optical quality and structure as a function of age.

    Science.gov (United States)

    Kuszak, J R; Al-Ghoul, K J; Novak, L A; Peterson, K L; Herbert, K L; Sivak, J G

    1999-05-06

    The Royal College of Surgeons (RCS) rat is an animal model for human retinal degenerative disease and posterior subcapsular cataracts (PSCs). The purpose of this study was to correlate the structure and optical quality of RCS lenses with PSCs as a function of their internalization, with normal, non-cataractous, age-matched control lenses. Correlative light (LM), scanning electron microscopic (SEM), three-dimensional computer assisted drawings (3D-CADs) and low power helium-neon laser scan analysis were used to examine the structure and function of lenses. The optical properties (average focal length variability; sharpness of focus) of RCS rat lenses are quantitatively compromised by PSCs. Correlative LM and SEM analysis of RCS lenses at various stages of PSC internalization (1.5, 3, 6, 9, 12 and 15 months of age), revealed that the sutures formed by additional fiber growth were progressively more abnormal. During PSC internalization, two to nine small suture branches were formed and arranged in modified line to multiple y configurations rather than the normal three branch y sutures. These temporal changes were also chronicled in animated 3D-CAD videos derived from lens reconstructions based on LM and SEM micrographs from the selected time points stated above. However, laser scan analysis also revealed that as the PSCs of RCS rat lenses were progressively internalized, there was a steady improvement in total sharpness of focus that reached normal levels by 12 months of age. The correlation of laser scan and structural data from specific regions of lenses revealed the following: 1. The abnormal posterior sutures of RCS rats with internalized PSCs effect a greater reduction in optical quality than normal posterior sutures of age-matched controls; 2. However, the resulting abnormal suture plane area was cumulatively similar to that of age-matched controls; 3. Thus, total optical quality was similar between RCS lenses with internalized PSCs and age-matched controls by

  1. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  2. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    Science.gov (United States)

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  3. Automatically rating trainee skill at a pediatric laparoscopic suturing task.

    Science.gov (United States)

    Oquendo, Yousi A; Riddle, Elijah W; Hiller, Dennis; Blinman, Thane A; Kuchenbecker, Katherine J

    2018-04-01

    Minimally invasive surgeons must acquire complex technical skills while minimizing patient risk, a challenge that is magnified in pediatric surgery. Trainees need realistic practice with frequent detailed feedback, but human grading is tedious and subjective. We aim to validate a novel motion-tracking system and algorithms that automatically evaluate trainee performance of a pediatric laparoscopic suturing task. Subjects (n = 32) ranging from medical students to fellows performed two trials of intracorporeal suturing in a custom pediatric laparoscopic box trainer after watching a video of ideal performance. The motions of the tools and endoscope were recorded over time using a magnetic sensing system, and both tool grip angles were recorded using handle-mounted flex sensors. An expert rated the 63 trial videos on five domains from the Objective Structured Assessment of Technical Skill (OSATS), yielding summed scores from 5 to 20. Motion data from each trial were processed to calculate 280 features. We used regularized least squares regression to identify the most predictive features from different subsets of the motion data and then built six regression tree models that predict summed OSATS score. Model accuracy was evaluated via leave-one-subject-out cross-validation. The model that used all sensor data streams performed best, achieving 71% accuracy at predicting summed scores within 2 points, 89% accuracy within 4, and a correlation of 0.85 with human ratings. 59% of the rounded average OSATS score predictions were perfect, and 100% were within 1 point. This model employed 87 features, including none based on completion time, 77 from tool tip motion, 3 from tool tip visibility, and 7 from grip angle. Our novel hardware and software automatically rated previously unseen trials with summed OSATS scores that closely match human expert ratings. Such a system facilitates more feedback-intensive surgical training and may yield insights into the fundamental

  4. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  5. Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairs.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H

    2010-03-01

    To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P row repair (P row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures

  6. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material.

    Science.gov (United States)

    Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M

    2008-11-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P row specimens was significantly higher than in others (P 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.

  7. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  8. An experimental propane bubble chamber

    International Nuclear Information System (INIS)

    Rogozinski, A.

    1957-01-01

    Describes a propane bubble chamber 10 cm in diameter and 5 cm deep. The body of the chamber is in stainless steel, and it has two windows of polished hardened glass. The compression and decompression of the propane are performed either through a piston in direct contact with the liquid, or by the action on the liquid, through a triple-mylar-Perbunan membrane, of a compressed gas. The general and also optimum working conditions of the chamber are described, and a few results are given concerning, in particular, the tests of the breakage-resistance of the windows and the measurements of the thermal expansion of the compressibility isotherm for the propane employed. (author) [fr

  9. Equipment for handling ionization chamber

    International Nuclear Information System (INIS)

    Altmann, J.

    1988-01-01

    The device consists of an ionization channel with an ionization chamber, of a support ring, axial and radial bearings, a sleeve, a screw gear and an electric motor. The ionization chamber is freely placed on the bottom of the ionization channel. The bottom part of the channel deviates from the vertical axis. The support ring propped against the axial bearing in the sleeve is firmly fixed to the top part of the ionization channel. The sleeve is fixed to the reactor lid. Its bottom part is provided with a recess for the radial bearing which is propped against a screw wheel firmly connected to the ionization channel. In measuring neutron flux, the screw wheel is rotated by the motor, thus rotating the whole ionization channel such that the ionization chamber is displaced into the reactor core.(J.B.). 1 fig

  10. General purpose nuclear irradiation chamber

    International Nuclear Information System (INIS)

    Nurul Fadzlin Hasbullah; Nuurul Iffah Che Omar; Nahrul Khair Alang Md Rashid; Jaafar Abdullah

    2013-01-01

    Nuclear technology has found a great need for use in medicine, industry, and research. Smoke detectors in our homes, medical treatments and new varieties of plants by irradiating its seeds are just a few examples of the benefits of nuclear technology. Portable neutron source such as Californium-252, available at Industrial Technology Division (BTI/ PAT), Malaysian Nuclear Agency, has a 2.645 year half-life. However, 252 Cf is known to emit gamma radiation from the source. Thus, this chamber aims to provide a proper gamma shielding for samples to distinguish the use of mixed neutron with gamma-rays or pure neutron radiation. The chamber is compatible to be used with other portable neutron sources such as 241 Am-Be as well as the reactor TRIGA PUSPATI for higher neutron dose. This chamber was designed through a collaborative effort of Kulliyyah Engineering, IIUM with the Industrial Technology Division (BTI) team, Malaysian Nuclear Agency. (Author)

  11. Holography in small bubble chambers

    International Nuclear Information System (INIS)

    Lecoq, P.

    1984-01-01

    This chapter reports on an experiment to determine the total charm cross section at different incident momenta using the small, heavy liquid bubble chamber HOBC. Holography in liquid hydrogen is also tested using the holographic lexan bubble chamber HOLEBC with the aim of preparing a future holographic experiment in hydrogen. The high intensity tests show that more than 100 incident tracks per hologram do not cause a dramatic effect on the picture quality. Hydrogen is more favorable than freon as the bubble growth is much slower in hydrogen. An advantage of holography is to have the maximum resolution in the full volume of the bubble chamber, which allows a gain in sensitivity by a factor of 10 compared to classical optics as 100 tracks per hologram look reasonable. Holograms are not more difficult to analyze than classical optics high-resolution pictures. The results show that holography is a very powerful technique which can be used in very high resolution particle physics experiments

  12. Cisternography of the posterior fossa with metrizamide

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, N.; Saito, Y.; Miyashita, T.; Tajika, Y.

    1981-12-01

    Nine patients underwent metrizamide cisternography of the posterior fossa. Excellent opacification of the fourth ventricle resulted when the patient's head was suitably positioned and the contrast material was introduced via a C1-2 puncture. With this technique, a benign aqueductal stenosis can be readily identified and the posterior fossa and fourth ventricle can be studied easily.

  13. Selective posterior lumbosacral rhizotomy for the management ...

    African Journals Online (AJOL)

    tion in 95% of cases. The majority showed ... selective posterior rhizotomy technique whereby the cauda equina ... assessed pre- and postoperatively by means of clinical examination ... were attending cerebral palsy schools and receiving spe- cialised ... root sections on cats demonstrated clearly that posterior root section ...

  14. Evaluation of the outcomes after posterior urethroplasty.

    Science.gov (United States)

    Liberman, Daniel; Pagliara, Travis J; Pisansky, Andrew; Elliott, Sean P

    2015-03-01

    Posterior urethral injury is a clinically significant complication of pelvic fractures. The management is complicated by the associated organ injuries, distortion of the pelvic anatomy and the ensuing fibrosis that occurs with urethral injury. We report a review of the outcomes after posterior urethroplasty in the context of pelvic fracture urethral injury.

  15. Effectiveness of ultrasonographic evaluation of the cranial sutures in children with suspected craniosynostosis

    Energy Technology Data Exchange (ETDEWEB)

    Simanovsky, Natalia; Hiller, Nurith; Koplewitz, Benjamin; Rozovsky, Katya [Hadassah Hebrew University Medical Center, Department of Medical Imaging, Mount, Scopus, P.O. Box 24035, Jerusalem (Israel)

    2009-03-15

    Computed tomography (CT) is the 'gold standard' for evaluation of the cranial sutures. While prenatal cranial suture evaluation with ultrasound (US) is common, US has not been established as a postnatal screening tool. We evaluated the effectiveness of US for diagnosis of craniosynostosis (CS). During 2006, 24 infants with questionable CS were assessed with US of the sagittal, metopic, and bilateral coronal and lambdoid sutures. US findings and clinical records were reviewed retrospectively. Sixteen boys and eight girls (ages 1-11 months, mean 4.3) underwent US. The correct diagnosis was provided in 23 (95%), with equivocal findings in one patient. Cranial sutures appeared normal in 15 infants, who had normal clinical presentation at mean 5.8 months follow-up; CT confirmation was obtained in two. In eight children, US identified premature closure of one or more cranial sutures. Three-dimensional CT was performed as a preparation for surgery in four, with classical CS findings. In one case with inconclusive US findings, CT showed narrow but open sutures. Sonographic examination of cranial sutures may serve as a first imaging tool for evaluation of craniosynostosis. CT may be reserved for children with abnormal or equivocal ultrasound and for preoperative planning. (orig.)

  16. Effectiveness of ultrasonographic evaluation of the cranial sutures in children with suspected craniosynostosis

    International Nuclear Information System (INIS)

    Simanovsky, Natalia; Hiller, Nurith; Koplewitz, Benjamin; Rozovsky, Katya

    2009-01-01

    Computed tomography (CT) is the 'gold standard' for evaluation of the cranial sutures. While prenatal cranial suture evaluation with ultrasound (US) is common, US has not been established as a postnatal screening tool. We evaluated the effectiveness of US for diagnosis of craniosynostosis (CS). During 2006, 24 infants with questionable CS were assessed with US of the sagittal, metopic, and bilateral coronal and lambdoid sutures. US findings and clinical records were reviewed retrospectively. Sixteen boys and eight girls (ages 1-11 months, mean 4.3) underwent US. The correct diagnosis was provided in 23 (95%), with equivocal findings in one patient. Cranial sutures appeared normal in 15 infants, who had normal clinical presentation at mean 5.8 months follow-up; CT confirmation was obtained in two. In eight children, US identified premature closure of one or more cranial sutures. Three-dimensional CT was performed as a preparation for surgery in four, with classical CS findings. In one case with inconclusive US findings, CT showed narrow but open sutures. Sonographic examination of cranial sutures may serve as a first imaging tool for evaluation of craniosynostosis. CT may be reserved for children with abnormal or equivocal ultrasound and for preoperative planning. (orig.)

  17. FGFR2c-mediated ERK-MAPK activity regulates coronal suture development

    Science.gov (United States)

    Pfaff, Miles J.; Xue, Ke; Li, Li; Horowitz, Mark C.; Steinbacher, Derek M.; Eswarakumar, Jacob V.P.

    2017-01-01

    Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor’s gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. PMID:27034231

  18. Anatomy-Based navigation for ventriculostomy: Nasion-coronal suture distance measurement

    Directory of Open Access Journals (Sweden)

    Mevci Özdemir

    2014-09-01

    Full Text Available Objective: In this study we aimed to determine a landmark that can be measured through the skin with nasal mid-point (bregma to coronal suture, and additionally an average value was calculated. We report, to our knowledge, the distance between the nasion-coronal sutures is reported for the first time in Turkish population. Methods: The study included 30 craniums and 30 frontal bones. Each skull from midline nasal suture to coronal suture curved up at the distance was measured with tape measure. Results: Mean values were determined. Nasal suture between coronal suture distance average 12,2 cm (min10,3 cm, up to 13,5 cm were detected. Conclusion: Nasal suture is an easily palpable area through the skin. A small incision is carried down through skin to bone at the spot 12 cm back from the nasion 3 cm lateral to the midline for ventricular drainage operation. This data provide practical information for neurosurgeon and is available everywhere. J Clin Exp Invest 2014; 5 (3: 368-370

  19. Immunostimulatory sutures that treat local disease recurrence following primary tumor resection

    Energy Technology Data Exchange (ETDEWEB)

    Intra, Janjira; Zhang Xueqing; Salem, Aliasger K [Division of Pharmaceutics, College of Pharmacy, University of Iowa, Iowa City, IA 52242 (United States); Williams, Robin L; Zhu Xiaoyan [Department of Surgery, Roy J and Lucille Carver College of Medicine, University of Iowa, Iowa City, IA 52242 (United States); Sandler, Anthony D, E-mail: aliasger-salem@uiowa.edu [Department of Surgery and Center for Cancer and Immunology Research, Children' s National Medical Center, Washington DC 20010 (United States)

    2011-02-15

    Neuroblastoma is a common childhood cancer that often results in progressive minimal residual disease after primary tumor resection. Cytosine-phosphorothioate-guanine oligonucleotides (CpG ODN) have been reported to induce potent anti-tumor immune responses. In this communication, we report on the development of a CpG ODN-loaded suture that can close up the wound following tumor excision and provide sustained localized delivery of CpG ODN to treat local disease recurrence. The suture was prepared by melt extruding a mixture of polylactic acid-co-glycolic acid (PLGA 75:25 0.47 dL g{sup -1}) pellets and CpG ODN 1826. Scanning electron microscopy images showed that the sutures were free of defects and cracks. UV spectrophotometry measurements at 260 nm showed that sutures provide sustained release of CpG ODN over 35 days. Syngeneic female A/J mice were inoculated subcutaneously with 1 x 10{sup 6} Neuro-2a murine neuroblastoma wild-type cells and tumors were grown between 5 to 10 mm before the tumors were excised. Wounds from the tumor resection were closed using CpG ODN-loaded sutures and/or polyglycolic acid Vicryl suture. Suppression of neuroblastoma recurrence and mouse survival were significantly higher in mice where wounds were closed using the CpG ODN-loaded sutures relative to all other groups. (communication)

  20. Popularity of suture materials among residents and faculty members of a postdoctoral periodontology program.

    Science.gov (United States)

    Maksoud, Mohamed; Koo, Samuel; Barouch, Kasumi; Karimbux, Nadeem

    2014-02-01

    The aim of the present study was to determine the favoritism of suture materials among a group of clinicians at a teaching institution. The surveys included 11 absorbable and nine non-absorbable sutures. The surveyor was asked to select his or her suture preferences when it comes to using it in 13 different, commonly-performed surgical procedures. The surveys showed overall preferences for non-absorbable versus absorbable sutures. Chromic Gut with a 4-0 diameter thread reverse cutting FS2 needle was the most favored suture. For periodontal bone grafts and hard tissue ridge augmentation, polytetrafluoroethylene with a 4-0 thread and FS2 needle was preferred. For autogenous gingival grafts, gingival allografts, connective tissue grafts, frenectomy and frenoplasty, Chromic Gut with 5-0 diameter thread reverse cutting P3 needle was favored. For extraction socket preservation, soft tissue canine exposure, ridge augmentation, and dental implants, Chromic Gut with 4-0 diameter thread reverse cutting FS2 needle was preferred, and for sinus augmentation, Vicryl with a 4-0 diameter thread reverse cutting FS2 needle was favored. Absorbable sutures were preferred in the majority of periodontal procedures; however, non-absorbable sutures were favored in procedures that required longer healing or better stability of the flap edges in cases of periodontal and ridge augmentation. © 2013 Wiley Publishing Asia Pty Ltd.

  1. Basic interrupted versus continuous suturing techniques in bronchial anastomosis following sleeve lobectomy in dogs.

    Science.gov (United States)

    Bayram, Ahmet Sami; Erol, Mehmet Muharrem; Salci, Hakan; Ozyiğit, Ozgür; Görgül, Sacit; Gebitekin, Cengiz

    2007-12-01

    Sleeve resection with or without lung resection is a valid conservative operation for patients with benign or malignant tumors; it enables the preservation of lung parenchyma. The aim of this prospective randomized study was to compare complications, operating time, and bronchial healing between the techniques of interrupted and continuous suturing for bronchial anastomosis in dogs. Twenty adult mongrel dogs each weighing 18-22 kg (average: 20 kg) were divided into two groups according to the anastomosis technique performed: group A, interrupted suturing and group B, continuous suturing. Each group comprised of 10 dogs. Following right thoracotomy, sleeve resection of the right cranial lobe was performed in all dogs. Basic interrupted sutures using 4/0 Vicryl (Ethicon, USA) were used in group A, and continuous sutures were used in group B. The median anastomosis time was 15.2 min (range: 13-21 min) in group A and 9.6 min (range: 8-13 min) in group B. In all dogs, the anastomosis line was resected via right pneumonectomy for histopathological investigation 1 month after sleeve resection. Histopathological examination revealed that the healing of the anastomosis was not affected by the suturing technique applied. One dog from each group died on the fourth postoperative day; Fisher's exact test, p=0.763. Our research revealed that the healing of the anastomosis was not affected by the suturing technique performed.

  2. Introduction of a New Suture Method in Repair of Peripheral Nerves Injured with a Sharp Mechanism

    Directory of Open Access Journals (Sweden)

    Alireza Saied

    2015-09-01

    Full Text Available Background: The standard method for repair of an injured peripheal nerve is epineural repair with separate sutures. Herein we describe a method in which the nerve is sutured with continous sutures. In fact this method has not been utilized for nerve repair previously and our purpose was to compare it to the standard method. If it proved to be successful it would replace the standard method in certain circumstances. Methods: The proposal of the clinical trial was given a reference number form the ethics comitee. 25 dogs in which the scaitic nerve was cut by a sharp blade under genaeral anesthesia were divided randomly into three groups: control (5 dogs, repair of sciatic nerve with simple sutures (10 and repair with continous sutures (10. In the control group the nerve was not repaired at all. After 6 weeks the dogs were killed and the nerve was studied by light and electronic microscopes. The amount of consumed suture material, time of repair, myelin thickness and axon diiameter were examined. Ultrastructural studies were performed to assess degeneration and regeneration findings. Results: Time of repair and the amount of consumed suture material were significantly lower in the continous group (P

  3. [An experimental assessment of methods for applying intestinal sutures in intestinal obstruction].

    Science.gov (United States)

    Akhmadudinov, M G

    1992-04-01

    The results of various methods used in applying intestinal sutures in obturation were studied. Three series of experiments were conducted on 30 dogs--resection of the intestine after obstruction with the formation of anastomoses by means of double-row suture (Albert--Shmiden--Lambert) in the first series (10 dogs), by a single-row suture after V. M. Mateshchuk [correction of Mateshuku] in the second series, and bu a single-row stretching suture suggested by the author in the third series. The postoperative complications and the parameters of physical airtightness of the intestinal anastomosis were studied in dynamics in the experimental animals. The results of the study: incompetence of the anastomosis sutures in the first series 6, in the second 4, and in the third series one. Adhesions occurred in all animals of the first and second series and in 2 of the third series. Six dogs of the first series died, 4 of the second, and one of the third. Study of the dynamics of the results showed a direct connection of the complications with the parameters of the physical airtightness of the anastomosis, and the last-named with the method of the intestinal suture. Relatively better results were noted in formation of the anastomosis by means of our suggested stretshing continuous suture passed through the serous, muscular, and submucous coats of the intestine.

  4. Normal Development of Sutures and synchondroses in the central skull base : CT study

    International Nuclear Information System (INIS)

    Roh, Hong Gee; Kim, Hyung Jin; Kang, Jee Hee; Lee, Kyung Hee; Lim, Myung Kwan; Cho, Young Kuk; Ok, Cheol Su; Suh, Chang Hae

    2000-01-01

    To evaluate the developmental patterns of the sutures and synchondroses in the central skull base. We evaluated the CT scans of 109 children (age range 29 days to 15 years) with no skull base abnormality who had undergone axial CT of the skull base with 1-mm collimation. Using a five-tier scheme, we analyzed the developmental patterns of the 18 sutures and synchondroses related to the sphenoid and occipital bones. Fusion of the sutures and synchondroses related to the sphenoid bone progressed rapidly during the first two years. Thereafter, changes in the sphenoid bone were dominated by pneumatization of the sphenoid sinus. Fusion of the synchondroses within the sphenoid body, including intersphenoidal, intrapresphenoidal, intrapostsphenoidal synchondrosis occurred early and in most cases was graded ≥3D4. Fusion of the sphenosquamosal, sphenoethmoidal, and frontosphenoidal sutures was delayed, and residual sclerosis was a common finding. Except for Kerckring-supraoccipital synchondrosis, fusion of the six sutures and synchondroses related to the occipital bone occurred more gradually than that of those related to the sphenoid bone. Among these, fusion of the occipitomastoidal suture and petro-occipital synchondrosis was the last to occur. A knowledge of the developmental patterns of sutures and synchondroses can help differentiate normal conditions from those such as fracture, osseous dysplasia, or congenital malformation, which are abnormal. Our results provide certain basic information about skull base maturity in children. (author)

  5. Test chamber for alpha spectrometry

    Science.gov (United States)

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  6. Laboratory Course on Drift Chambers

    International Nuclear Information System (INIS)

    Garcia-Ferreira, Ix-B.; Garcia-Herrera, J.; Villasenor, L.

    2006-01-01

    Drift chambers play an important role in particle physics experiments as tracking detectors. We started this laboratory course with a brief review of the theoretical background and then moved on to the the experimental setup which consisted of a single-sided, single-cell drift chamber. We also used a plastic scintillator paddle, standard P-10 gas mixture (90% Ar, 10% CH4) and a collimated 90Sr source. During the laboratory session the students performend measurements of the following quantities: a) drift velocities and their variations as function of the drift field; b) gas gains and c) diffusion of electrons as they drifted in the gas

  7. The knife-edge chamber

    International Nuclear Information System (INIS)

    Barasch, E.F.; Bowcock, T.J.V.; Drew, M.M.; Elliott, S.M.; Lee, B.; McIntyre, P.M.; Pang, Y.; Popovic, M.; Smith, D.D.

    1990-01-01

    In this paper the design for a new technology for particle track detectors is described. Using standard IC fabrication techniques, a pattern of microscopic knife edges and field-shaping electrodes can be fabricated on a silicon substrate. The knife-edge chamber uniquely offers attractive performance for the track chambers required for SSC detectors, for which no present technology is yet satisfactory. Its features include: excellent radiation hardness (10 Mrad), excellent spatial resolution (∼20 μm), short drift time (20 ns), and large pulse height (1 mV)

  8. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    2010-01-01

    resolution and high sensitivity are necessary. For exact dosimetry which is done using ionization chambers (ICs), the recombination taking place in the IC has to be known. Up to now, recombination is corrected phenomenologically and more practical approaches are currently used. Nevertheless, Jaff´e's theory...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  9. The Mark III vertex chamber

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.

    1987-07-01

    The design and construction of the new Mark III vertex chamber is described. Initial tests with cosmic rays prove the ability of track reconstruction and yield triplet resolutions below 50 μm at 3 atm using argon/ethane (50:50). Also performed are studies using a prototype of a pressurized wire vertex chamber with 8 mm diameter straw geometry. Spatial resolution of 35mm was obtained using dimethyl ether (DME) at 1 atm and 30 μm using argon/ethane (50/50 mixture) at 4 atm. Preliminary studies indicate the DME to adversely affect such materials as aluminized Mylar and Delrin

  10. Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses.

    Science.gov (United States)

    Baumgartner, N; Dobrin, P B; Morasch, M; Dong, Q S; Mrkvicka, R

    1996-05-01

    Experiments were performed in dogs to evaluate the mechanics of 26 end-to-end and 42 end-to-side artery-vein graft anastomoses constructed with continuous polypropylene sutures (Surgilene; Davis & Geck, Division of American Cyanamid Co., Danbury, Conn.), continuous polybutester sutures (Novafil; Davis & Geck), and interrupted stitches with either suture material. After construction, the grafts and adjoining arteries were excised, mounted in vitro at in situ length, filled with a dilute barium sulfate suspension, and pressurized in 25 mm Hg steps up to 200 mm Hg. Radiographs were obtained at each pressure. The computed cross-sectional areas of the anastomoses were compared with those of the native arteries at corresponding pressures. Results showed that for the end-to-end anastomoses at 100 mm Hg the cross-sectional areas of the continuous Surgilene anastomoses were 70% of the native artery cross-sectional areas, the cross-sectional areas of the continuous Novafil anastomoses were 90% of the native artery cross-sectional areas, and the cross-sectional areas of the interrupted anastomoses were 107% of the native artery cross-sectional areas (p anastomoses demonstrated no differences in cross-sectional areas or compliance for the three suture techniques. This suggests that, unlike with end-to-end anastomoses, when constructing an end-to-side anastomosis in patients any of the three suture techniques may be acceptable.

  11. Interfascicular suture with nerve autografts for median, ulnar and radial nerve lesions.

    Science.gov (United States)

    Pluchino, F; Luccarelli, G

    1981-05-01

    Interfascicular nerve suture with autografts is the operation of choice for repairing peripheral nerve injuries because it ensures more precise alignment of the fasciculi and so better chances of reinnervation of the sectioned nerve. The procedure as described by Millesi et al has been used at the Istituto Neurologico di Milano in 30 patients with traumatic lesions of the median, ulnar and radial nerves. All have been followed up for 2 to 7 years since operation. The results obtained are compared with those of other series obtained with interfascicular suture and with epineural suture. Microsurgery is essential. The best time to operate is discussed.

  12. Brief communication: age and fractal dimensions of human sagittal and coronal sutures

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Jacobsen, Jens Christian Brings

    2003-01-01

    The fractal dimensions of human sagittal and coronal sutures were calculated on 31 complete skulls from the Terry Collection. The aim was to investigate whether the fractal dimension, relying on the whole sutural length, might yield a better description of age-related changes in sutural morphology......, as opposed to other methods of quantification, which generally rely on more arbitrary scoring systems. However, the fractal dimension did not yield better age correlations than other previously described methods. At best, the results reflected the general observation that young adults below age 40 years...

  13. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  14. Celastrol nanoparticles inhibit corneal neovascularization induced by suturing in rats

    Directory of Open Access Journals (Sweden)

    Li ZR

    2012-03-01

    Full Text Available Zhanrong Li1, Lin Yao1, Jingguo Li2, Wenxin Zhang1, Xianghua Wu1, Yi Liu1, Miaoli Lin1, Wenru Su1, Yongping Li1, Dan Liang11State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, 2School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou, People's Republic of ChinaPurpose: Celastrol, a traditional Chinese medicine, is widely used in anti-inflammation and anti-angiogenesis research. However, the poor water solubility of celastrol restricts its further application. This paper aims to study the effect of celastrol nanoparticles (CNPs on corneal neovascularization (CNV and determine the possible mechanism.Methods: To improve the hydrophilicity of celastrol, celastrol-loaded poly(ethylene glycol-block-poly(ε-caprolactone nanopolymeric micelles were developed. The characterization of CNPs was measured by dynamic light scattering and transmission electron microscopy analysis. Celastrol loading content and release were assessed by ultraviolet-visible analysis and high performance liquid chromatography, respectively. In vitro, human umbilical vein endothelial cell proliferation and capillary-like tube formation were assayed. In vivo, suture-induced CNV was chosen to evaluate the effect of CNPs on CNV in rats. Immunohistochemistry for CD68 assessed the macrophage infiltration of the cornea on day 6 after surgery. Real-time quantitative reverse transcription-polymerase chain reaction and enzyme-linked immunosorbent assay were used to evaluate the messenger ribonucleic acid and protein levels, respectively, of vascular endothelial growth factor, matrix metalloproteinase 9, and monocyte chemoattractant protein 1 in the cornea.Results: The mean diameter of CNPs with spherical shape was 48 nm. The celastrol loading content was 7.36%. The release behavior of CNPs in buffered solution (pH 7.4 showed a typical two-phase release profile. CNPs inhibited the proliferation of human umbilical vein endothelial

  15. Testing an hydrogen streamer chamber

    CERN Multimedia

    1975-01-01

    A 2x10 cm gap streamer chamber, 35x55 cm2 in surface, was built and tested at CERN. Good tracks of cosmic rays were obtained up to atmospheric pressure, see F. Rohrbach et al, CERN-LAL (Orsay) Collaboration, Nucl. Instr. Methods 141 (1977) 229. Michel Cathenoz stand on the center.

  16. Bubble chamber: colour enhanced tracks

    CERN Multimedia

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  17. A rare case of persistent metopic suture in an elderly individual: Incidental autopsy finding with clinical implications

    Directory of Open Access Journals (Sweden)

    S Vikram

    2014-01-01

    Full Text Available Metopic suture is a dense fibrous joint extending from the nasion to the bregma. Normally, closure of this suture takes place between 1-8 years of age. Failure of this closure beyond 8 years leads to persistent metopic suture. A rare case of persistent metopic suture in a 60-year-old male is documented, who committed suicide by alleged consumption of organophosphorous compound at District Govt. Wenlock Hospital, Mangalore, Karnataka, India. Metopic suture may mimic skull fracture and may mislead an inexperienced forensic expert. Neurosurgeon should also be aware of this anatomical variation while performing frontal craniotomy, as the persistent metopic suture may mimic vertical fracture of the skull. Hence, in this case report, the clinical and medico-legal implications of the persistent metopic sutures have been discussed.

  18. Posterior labral injury in contact athletes.

    Science.gov (United States)

    Mair, S D; Zarzour, R H; Speer, K P

    1998-01-01

    Nine athletes (seven football offensive linemen, one defensive lineman, and one lacrosse player) were found at arthroscopy to have posterior labral detachment from the glenoid. In our series, this lesion is specific to contact athletes who engage their opponents with arms in front of the body. All patients had pain with bench pressing and while participating in their sport, diminishing their ability to play effectively. Conservative measures were ineffective in relieving their symptoms. Examination under anesthesia revealed symmetric glenohumeral translation bilaterally, without evidence of posterior instability. Treatment consisted of glenoid rim abradement and posterior labral repair with a bioabsorbable tack. All patients returned to complete at least one full season of contact sports and weightlifting without pain (minimum follow-up, > or = 2 years). Although many injuries leading to subluxation of the glenohumeral joint occur when an unanticipated force is applied, contact athletes ready their shoulder muscles in anticipation of impact with opponents. This leads to a compressive force at the glenohumeral joint. We hypothesize that, in combination with a posteriorly directed force at impact, the resultant vector is a shearing force to the posterior labrum and articular surface. Repeated exposure leads to posterior labral detachment without capsular injury. Posterior labral reattachment provides consistently good results, allowing the athlete to return to competition.

  19. Treatment implications of posterior fossa ependymoma subgroups.

    Science.gov (United States)

    Ramaswamy, Vijay; Taylor, Michael D

    2016-11-15

    Posterior fossa ependymoma comprises two distinct molecular entities, ependymoma_posterior fossa A (EPN_PFA) and ependymoma_posterior fossa B (EPN_PFB), with differentiable gene expression profiles. As yet, the response of the two entities to treatment is unclear. To determine the relationship between the two molecular subgroups of posterior fossa ependymoma and treatment, we studied a cohort of 820 patients with molecularly profiled, clinically annotated posterior fossa ependymomas. We found that the strongest predictor of poor outcome in patients with posterior fossa ependymoma across the entire age spectrum was molecular subgroup EPN_PFA, which was recently reported in the paper entitled "Therapeutic impact of cytoreductive surgery and irradiation of posterior fossa ependymoma in the molecular era: a retrospective multicohort analysis" in the Journal of Clinical Oncology. Patients with incompletely resected EPN_PFA tumors had a very poor outcome despite receiving adjuvant radiation therapy, whereas a substantial proportion of patients with EPN_PFB tumors can be cured with surgery alone.

  20. Posterior encephalopathy with vasospasm: MRI and angiography

    International Nuclear Information System (INIS)

    Weidauer, S.; Gaa, J.; Lanfermann, H.; Zanella, F.E.; Sitzer, M.; Hefner, R.

    2003-01-01

    Posterior encephalopathy is characterised by headache, impairment of consciousness, seizures and progressive visual loss. MRI shows bilateral, predominantly posterior, cortical and subcortical lesions with a distribution. Our aim was to analyse the MRI lesion pattern and angiographic findings because the pathophysiology of posterior encephalopathy is incompletely understood. We report three patients with clinical and imaging findings consistent with posterior encephalopathy who underwent serial MRI including diffusion-weighted imaging (DWI) and construction of apparent diffusion coefficient (ADC) maps, and four-vessel digital subtraction angiography (DSA). DWI revealed symmetrical subcortical and cortical parieto-occipital high signal. High and also low ADCs indicated probable vasogenic and cytotoxic oedema. On follow-up there was focal cortical laminar necrosis, while the white-matter lesions resolved almost completely, except in the arterial border zones. DSA revealed diffuse arterial narrowing, slightly more marked in the posterior circulation. These findings suggest that posterior encephalopathy may in some cases be due to diffuse, severe vasospasm affecting especially in the parieto-occipital grey matter, with its higher vulnerability to ischemia. Cerebral vasospasm due to digitoxin intoxication, resulting in posterior encephalopathy, has not yet been described previously. (orig.)

  1. Fixation in laparoscopic incisional hernia repair: Suture versus tacks

    Directory of Open Access Journals (Sweden)

    Adil Bangash

    2013-01-01

    Full Text Available Aims and Objectives: To compare the frequency of complications of laparoscopic repair of incisional hernia using fixation of mesh with transabdominal sutures tacks. Materials and Methods: This study was conducted as part of an interventional multicenter trial at the Rehman Medical Institute, Peshawar, Peshawar Institute of Medical Sciences, and Pakistan Institute of Medical Science, Islamabad, from the 1 st of November 2008 till 31 st October 2011. The frequency of complications was calculated as the measure of comparing two methods of fixation in laparoscopic repair of incisional hernia using the IPOM technique. These patients were admitted via the outpatient department and their demographic data were collected on a pro forma basis. Forty-five patients were alternately placed in either group, and group I comprised patients with a ventral hernia that was fixed using spiral tacks whereas the other group was fixed with transabdominal sutures. A polytetraflouroethylene (Dual R mesh was applied in all cases. All data were collected onthe individual pro forma of each patient and was loaded on the SPSS R version 13.0. Results: The BMI in both groups was similar (P=0.94 The mean hospital stay was higher in the PTFE mesh group but the values were not significant (P=1.22.No perioperative death was observed in either group. One patient (2.2% from group I was readmitted with varying complaints and was diagnosed as having subacute intestinal obstruction (P>0.05. A higher but insignificant recurrence rate was observed in the polyester group over a one-year period of follow-up. Three patients (6.6% were diagnosed with recurrences in group I. Instead the PTFE group had a similar recurrence rate recurrence (P=1.00. Conclusion: The rate of recurrence in this study showed no significant difference by either mode of fixation. But statistically significant pain scores and increased operative time to fixation favors the use of tacks that limits to the few inner

  2. Hydrostatic Hyperbaric Chamber Ventilation System

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware

  3. Overcoming the learning curve of single-port total laparoscopic hysterectomy with barbed suture: a single surgeon's initial experience.

    Science.gov (United States)

    Lee, Yoon Hee; Chong, Gun Oh; Kim, Mi Ju; Gy Hong, Dae; Lee, Yoon Soon

    2017-09-01

    Single-port total laparoscopic hysterectomy (TLH) has not been widely used because of its technical difficulty and steep learning curve, especially the laparoscopic suturing of the vaginal stump. Barbed suturing is a new technology that has the potential to greatly facilitate laparoscopic suturing. To compare surgical outcomes and vaginal vault healing between barbed sutures and traditional sutures in the repair of the vaginal vault during single-port TLH. Between August 2013 and June 2015, we performed single-port TLH in 85 consecutive patients for benign or premalignant gynecological conditions. The first 48 patients underwent single-port TLH with traditional interrupted sutures, and the next 37 patients underwent single-port TLH with absorbable unidirectional knotless barbed sutures for repair of the vaginal vault. The patient characteristics (age, body mass index), procedures performed, uterine weight, and uterine disease were similar between the groups. There were no differences in blood loss, hemoglobin change, length of hospital stay, or perioperative complications. Operative time and the time required for vaginal cuff suturing were significantly shorter in the barbed suture group than in the traditional suture group (57.8 ±13.5 vs. 80.1 ±18.7 min, p < 0.001; 5.5 ±1.7 vs. 12.9 ±3.5 min, p < 0.001). Moreover, the use of barbed sutures significantly reduced the incidence of vaginal granulation tissue formation (2.7% vs. 35.4%, p < 0.001). Use of barbed sutures in single-port TLH reduced the operative time, suturing time of the vaginal vault, and formation of vaginal granulation tissue. Barbed suturing may help overcome surgical difficulties and vaginal cuff complications.

  4. Shyok Suture Zone, N Pakistan: late Mesozoic Tertiary evolution of a critical suture separating the oceanic Ladakh Arc from the Asian continental margin

    Science.gov (United States)

    Robertson, Alastair H. F.; Collins, Alan S.

    2002-02-01

    The Shyok Suture Zone (Northern Suture) of North Pakistan is an important Cretaceous-Tertiary suture separating the Asian continent (Karakoram) from the Cretaceous Kohistan-Ladakh oceanic arc to the south. In previously published interpretations, the Shyok Suture Zone marks either the site of subduction of a wide Tethyan ocean, or represents an Early Cretaceous intra-continental marginal basin along the southern margin of Asia. To shed light on alternative hypotheses, a sedimentological, structural and igneous geochemical study was made of a well-exposed traverse in North Pakistan, in the Skardu area (Baltistan). To the south of the Shyok Suture Zone in this area is the Ladakh Arc and its Late Cretaceous, mainly volcanogenic, sedimentary cover (Burje-La Formation). The Shyok Suture Zone extends northwards (ca. 30 km) to the late Tertiary Main Karakoram Thrust that transported Asian, mainly high-grade metamorphic rocks southwards over the suture zone. The Shyok Suture Zone is dominated by four contrasting units separated by thrusts, as follows: (1). The lowermost, Askore amphibolite, is mainly amphibolite facies meta-basites and turbiditic meta-sediments interpreted as early marginal basin rift products, or trapped Tethyan oceanic crust, metamorphosed during later arc rifting. (2). The overlying Pakora Formation is a very thick (ca. 7 km in outcrop) succession of greenschist facies volcaniclastic sandstones, redeposited limestones and subordinate basaltic-andesitic extrusives and flow breccias of at least partly Early Cretaceous age. The Pakora Formation lacks terrigenous continental detritus and is interpreted as a proximal base-of-slope apron related to rifting of the oceanic Ladakh Arc; (3). The Tectonic Melange (ocean ridge-type volcanics and recrystallised radiolarian cherts, interpreted as accreted oceanic crust. (4). The Bauma-Harel Group (structurally highest) is a thick succession (several km) of Ordovician and Carboniferous to Permian-Triassic, low

  5. Comparison of surgical time and complication rate of subcutaneous and skin closure using barbed suture or traditional knotted suture in dogs.

    Science.gov (United States)

    Nutt, Laura K; Wilson, Megan L; Sakals, Sherisse

    2017-12-01

    This prospective study evaluated the handling, intraoperative and postoperative complication rates of a barbed knotless suture for closure of subcutaneous tissue and skin in 17 client-owned dogs (group A) following a tibial plateau leveling osteotomy procedure. Clinical characteristics, surgical time, and complication rates were compared to a control group of 17 client-owned dogs (group B) with subcutaneous tissue and skin closure using traditional suture material. Signalment was not significantly different between groups and did not have an effect on complication rates. Surgical times were not significantly different for subcutaneous tissue or skin closure between the 2 groups. There were significantly more intraoperative complications in the barbed suture group (A: 4/17; B: 0/17; P = 0.033) but no difference in minor or major postoperative complication rates (minor A: 2/16; B: 1/14; P = 0.626, major A: 2/16; B: 0/14; P = 0.171).

  6. The suture provides a niche for mesenchymal stem cells of craniofacial bones

    Science.gov (United States)

    Zhao, Hu; Feng, Jifan; Ho, Thach-Vu; Grimes, Weston; Urata, Mark; Chai, Yang

    2015-01-01

    Bone tissue undergoes constant turnover supported by stem cells. Recent studies showed that perivascular mesenchymal stem cells (MSCs) contribute to the turnover of long bones. Craniofacial bones are flat bones derived from a different embryonic origin than the long bones. The identity and regulating niche for craniofacial bone MSCs remain unknown. Here, we identify Gli1+ cells within the suture mesenchyme as the major MSC population for craniofacial bones. They are not associated with vasculature, give rise to all craniofacial bones in the adult and are activated during injury repair. Gli1+ cells are typical MSCs in vitro. Ablation of Gli1+ cells leads to craniosynostosis and arrest of skull growth, indicating these cells are an indispensible stem cell population. Twist1+/− mice with craniosynostosis show reduced Gli1+ MSCs in sutures, suggesting that craniosynostosis may result from diminished suture stem cells. Our study indicates that craniofacial sutures provide a unique niche for MSCs for craniofacial bone homeostasis and repair. PMID:25799059

  7. Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing.

    Science.gov (United States)

    Brand, Jefferson C

    2017-06-01

    Barber's biomechanical work is well known to Arthroscopy's readers as thorough, comprehensive, and inclusive of new designs as they become available. In "All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode," the latest iteration, Barber and Herbert test all-suture anchors in both porcine femurs and biphasic foam. While we await in vivo clinical trials that compare all-suture anchors to currently used anchors, Barber and Herbert have provided data to inform anchor choice, and using their biomechanical data at time zero from all-suture anchor trials in an animal model, we can determine the anchors' feasibility for human clinical investigations. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Gonioscopy-assisted Transluminal Trabeculotomy (GATT): Thermal Suture Modification With a Dye-stained Rounded Tip.

    Science.gov (United States)

    Grover, Davinder S; Fellman, Ronald L

    2016-06-01

    To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.

  9. Shape memory alloy fixator system for suturing tissue in minimal access surgery.

    Science.gov (United States)

    Xu, W; Frank, T G; Stockham, G; Cuschieri, A

    1999-01-01

    A new technique for suturing human tissue is described in which tissue closure is achieved by means of small fixators made from shape memory alloy. The aim of the development is to provide an alternative to thread suturing in minimal access surgery, which is quicker and requires less skill to achieve the required suturing quality. The design of the fixators is described in terms of the thermal shape recovery of shape memory alloy and a novel form of finite element analysis, which uses a nonlinear elastic element for the material property. Thermal analysis of the fixators and surrounding tissue is used to predict the temperature distribution during and after the application of electric current heating. This was checked in an in vitro experiment, which confirmed that deployment caused no detectable collateral damage to surrounding tissue. In vivo animal studies on the use of the shape memory alloy fixator for suturing tissue are ongoing to establish safety and healing effects.

  10. Evaluation of endoscopic laser excision of polypropylene mesh/sutures following anti-incontinence procedures.

    LENUS (Irish Health Repository)

    Davis, N F

    2012-11-01

    We reviewed our experience with and outcome of the largest series to our knowledge of patients who underwent endoscopic laser excision of eroded polypropylene mesh or sutures as a complication of previous anti-incontinence procedures.

  11. Safety and efficacy of unidirectional barbed suture in mini-laparotomy myomectomy

    Directory of Open Access Journals (Sweden)

    Ming-Chao Huang

    2013-03-01

    Conclusion: The unidirectional knotless barbed suture may facilitate the repair of uterine defects during mini-laparotomy myomectomy by significantly lowering operative time. It may also reduce the intraoperative blood loss.

  12. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  13. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  14. Comparable biomechanical results for a modified single-row rotator cuff reconstruction using triple-loaded suture anchors versus a suture-bridging double-row repair.

    Science.gov (United States)

    Lorbach, Olaf; Kieb, Matthias; Raber, Florian; Busch, Lüder C; Kohn, Dieter; Pape, Dietrich

    2012-02-01

    To compare the biomechanical properties and footprint coverage of a single-row (SR) repair using a modified suture configuration versus a double-row (DR) suture-bridge repair in small to medium and medium to large rotator cuff tears. We created 25- and 35-mm artificial defects in the rotator cuff of 24 human cadaveric shoulders. The reconstructions were performed as either an SR repair with triple-loaded suture anchors (2 to 3 anchors) and a modified suture configuration or a modified suture-bridge DR repair (4 to 6 anchors). Reconstructions were cyclically loaded from 10 to 60 N. The load was increased stepwise up to 100, 180, and 250 N. Cyclic displacement and load to failure were determined. Furthermore, footprint widths were quantified. In the 25-mm rupture, ultimate load to failure was 533 ± 107 N for the SR repair and 681 ± 250 N for the DR technique (P ≥ .21). In the 35-mm tear, ultimate load to failure was 792 ± 122 N for the SR reconstruction and 891 ± 174 N for the DR reconstruction (P ≥ .28). There were no statistically significant differences for both tested rupture sizes. Cyclic displacement showed no significant differences between the tested configurations at 60 N (P = .563), 100 N (P = .171), 180 N (P = .211), and 250 N (P = .478) for the 25-mm tear. For the 35-mm tear, cyclic displacement showed significantly lower gap formation for the SR reconstruction at 180 N (P = .037) and 250 N (P = .020). No significant differences were found at 60 N (P = .296) and 100 N (P = .077). A significantly greater footprint width (P = .028) was seen for the DR repair (16.2 mm) compared with the SR repair (13.8 mm). However, both reconstructions were able to achieve complete footprint coverage compared with the initial footprint. The tested SR repair using a modified suture configuration was similar in load to failure and cyclic displacement to the DR suture-bridge technique independent of the tested initial sizes of the rupture. The tested DR repair

  15. Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

    Science.gov (United States)

    Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D

    2011-10-01

    To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.

  16. A single centre comparative study of laparoscopic mesh rectopexy versus suture rectopexy

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Aim: The aim of our study is to compare the results of laparoscopic mesh vs. suture rectopexy. Materials and Methods: In this retrospective study, 70 patients including both male and female of age ranging between 20 years and 65 years (mean 42.5 yrs were subjected to laparoscopic rectopexy during the period between March 2007 and June 2012, of which 38 patients underwent laparoscopic mesh rectopexy and 32 patients laparoscopic suture rectopexy. These patients were followed up for a mean period of 12 months assessing first bowel movement, hospital stay, duration of surgery, faecal incontinence, constipation, recurrence and morbidity. Results: Duration of surgery was 100.8 ± 12.4 minutes in laparoscopic suture rectopexy and 120 ± 10.8 min in laparoscopic mesh rectopexy. Postoperatively, the mean time for the first bowel movement was 38 hrs and 40 hrs, respectively, for suture and mesh rectopexy. Mean hospital stay was five (range: 4-7 days. There was no significant postoperative complication except for one port site infection in mesh rectopexy group. Patients who had varying degree of incontinence preoperatively showed improvement after surgery. Eleven out of 18 (61.1% patients who underwent laparoscopic suture rectopexy as compared to nine of 19 (47.3% patients who underwent laparoscopic mesh rectopexy improved as regards constipation after surgery. Conclusion: There were no significant difference in both groups who underwent surgery except for patients undergoing suture rectopexy had better symptomatic improvement of continence and constipation. Also, cost of mesh used in laparoscopic mesh rectopexy is absent in lap suture rectopexy group. To conclude that laparoscopic suture rectopexy is a safe and feasible procedure and have comparable results as regards operative time, morbidity, bowel function, cost and recurrence or even slightly better results than mesh rectopexy.

  17. Experimental studies on the influence of irradiation (60Co) on wound healing of colonic suture

    International Nuclear Information System (INIS)

    Shoji, Munehiro

    1980-01-01

    Effects of preoperative 60 Co irradiation on wound healing of colonic suture in adult dogs of mixed breed were discussed. Wound healing 7 days after colonic suture was compared among dogs which received colonic suture immediately, or 3 days, or 7 days after the 60 Co irradiation. As a result, there was not a big difference in their wound healing among these dogs, and disorders of wound healing were not found. Bursting pressure at sutured sites was always lower in irradiated dogs than controls. Recovery of the bursting pressure was 2 days slower in irradiated dogs than non-irradiated dogs for 7 days after the suture. Bursting pressure was the lowest on the 3rd day after the suture in both groups. As to fine changes in irradiated dogs, appearance of recommunicating phenomena in blood vessels, delay of a decrease in avascular regions, delay of granulation, and hypertrophy of vascular walls seemed to be influenced by 60 Co irradiation, but there was not a big difference in these results between irradiated and non-irradiated dogs. An increase in postoperative concentration of hydroproline tended to be little lower in irradiated dogs than controls, which seemed to be influenced by the 60 Co irradiation. This result was also suggested from delay of granulation and remaining inflammations. Effects of 60 Co irradiation on wound healing of colonic suture seemed to be slight generally, because ruptured suture scarecely occurred in the irradiated dogs. When doses used in this experiment were calculated roughly by Ellis's method, irradiation of 60 Co seemed not to influence seriously wound healing if the total of 2,000 to 2,500 rad was irradiated in 8 to 10 doses to human colon. (Tsunoda, M.)

  18. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  19. Posterior alien hand syndrome: case report

    International Nuclear Information System (INIS)

    Rohde, S.; Weidauer, S.; Lanfermann, H.; Zanella, F.

    2002-01-01

    The alien hand syndrome (AHS) is involuntary uncontrolled movement of an arm with a sense of estrangement from the limb itself. AHS was initially used to describe interhemispheric disconnection phenomena in patients with lesions in the anterior corpus callosum, but it has been found in patients with posterior cerebral lesions without involvement of the corpus callosum, for example parietal infarcts or corticobasal degeneration. The posterior alien hand syndrome is less frequent and presents with nonpurposive behaviour like lifting the arm or writhing fingers. We report an 80-year-old woman with a posterior AHS of the dominant right hand. MRI showed atrophy of the pre- and postcentral gyri without involvement of the corpus callosum. We discuss the aetiology of the posterior AHS and the differences from the anterior varieties. (orig.)

  20. Posterior reversible encephalopathy syndrome: Some novel ...

    African Journals Online (AJOL)

    The third, a thalassaemic child receiving regular blood transfusions, had PRES ... anterior brain instead of the classically described posterior parts of .... 7 months. 3 years. 5 years. 4 years. Gender. Female. Male. Female. Female ... Developed.

  1. Congenital abnormalities of the posterior fossa.

    Science.gov (United States)

    Bosemani, Thangamadhan; Orman, Gunes; Boltshauser, Eugen; Tekes, Aylin; Huisman, Thierry A G M; Poretti, Andrea

    2015-01-01

    The frequency and importance of the evaluation of the posterior fossa have increased significantly over the past 20 years owing to advances in neuroimaging. Nowadays, conventional and advanced neuroimaging techniques allow detailed evaluation of the complex anatomic structures within the posterior fossa. A wide spectrum of congenital abnormalities has been demonstrated, including malformations (anomalies due to an alteration of the primary developmental program caused by a genetic defect) and disruptions (anomalies due to the breakdown of a structure that had a normal developmental potential). Familiarity with the spectrum of congenital posterior fossa anomalies and their well-defined diagnostic criteria is crucial for optimal therapy, an accurate prognosis, and correct genetic counseling. The authors discuss the spectrum of posterior fossa malformations and disruptions, with emphasis on neuroimaging findings (including diagnostic criteria), neurologic presentation, systemic involvement, prognosis, and risk of recurrence. RSNA, 2015

  2. POSTERIOR APPROACH FOR HIP ARTHROPLASTY: A SINGLE ...

    African Journals Online (AJOL)

    postulated advantages and disadvantages. Objective: Presentation of a case series of primary and revision arthroplasty utilizing the posterior approach. ... Centre over a period of one year were queried and data extracted and recorded.

  3. Posterior Fossa Tumors and Intellectual Impairment

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2005-01-01

    Full Text Available The effect of cerebellar damage on intellectual function in 76 children treated surgically for malignant posterior fossa tumor was investigated at the Gustave Roussy Institute, Villejuif, and the Department of Pediatric Neurosurgery, Necker Hospital, Paris, France.

  4. Sutura palatina mediana: avaliação do grau de ossificação em crânios humanos Mid-palatal suture: evaluation of the ossification degree in human skulls

    Directory of Open Access Journals (Sweden)

    Jussara Ennes

    2004-10-01

    Full Text Available OBJETIVOS: Avaliar o grau de ossificação da sutura palatina mediana em crânios humanos de diferentes grupos etários. AMOSTRA: Crânios humanos (28 divididos em quatro grupos de acordo com a fase do desenvolvimento cronológico: crianças, adultos jovens, adultos e idosos. MATERIAL: Radiografias Oclusais Totais da Maxila dos crânios dos diferentes grupos (28. Imagens digitalizadas das Radiografias Oclusais Totais da Maxila (28. MÉTODOS: A presença de pontes de ossificação na sutura palatina mediana foi identificada macroscópica e estereomicroscopicamente, registrada e quantificada. Os crânios foram radiografados pela Técnica Oclusal total da Maxila, com modificação na posição do filme, no eixo horizontal. As imagens radiográficas obtidas foram digitalizadas e submetidas à variação de tons claros e escuros e ao ajuste de contraste e brilho para a investigação do grau de ossificação da sutura palatina mediana. CONCLUSÃO: Concluiu-se que a ossificação da sutura palatina mediana inicia-se principalmente na fase adulta e no segmento posterior. A técnica Radiográfica Oclusal Total da Maxila não proporciona imagem adequada à identificação do grau de ossificação na sutura palatina mediana.OBJECTIVES: To analyze the mid-palatal suture ossification rate on human skulls. SAMPLE: Human skulls (28 divided among four groups according to chronological developmental phases: child, teen-ager, adult and elderly. MATERIAL: Maxillary Total Occlusal radiographs from different groups of skulls (28. Digitalized images from Maxillary Total Occlusal radiographs (28. METHODS: The presence of ossification bridges on the mid-palatal suture were identified, registered and qualified. The radiographs of the skulls were taken using the Maxillary Total Occlusal technique, modifying the horizontal position of the film. These radiograph images were digitalized and submitted to brightness and contrast adjustments to investigate mid-palatal suture

  5. Investigation of the best suture pattern to close a stuffed Christmas turkey.

    Science.gov (United States)

    Verwilghen, D; Busoni, V; van Galen, G; Wilke, M

    Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.

  6. Identification and dynamics of a cryptic suture zone in tropical rainforest

    Science.gov (United States)

    Moritz, C.; Hoskin, C.J.; MacKenzie, J.B.; Phillips, B.L.; Tonione, M.; Silva, N.; VanDerWal, J.; Williams, S.E.; Graham, C.H.

    2009-01-01

    Suture zones, shared regions of secondary contact between long-isolated lineages, are natural laboratories for studying divergence and speciation. For tropical rainforest, the existence of suture zones and their significance for speciation has been controversial. Using comparative phylogeographic evidence, we locate a morphologically cryptic suture zone in the Australian Wet Tropics rainforest. Fourteen out of 18 contacts involve morphologically cryptic phylogeographic lineages, with mtDNA sequence divergences ranging from 2 to 15 per cent. Contact zones are significantly clustered in a suture zone located between two major Quaternary refugia. Within this area, there is a trend for secondary contacts to occur in regions with low environmental suitability relative to both adjacent refugia and, by inference, the parental lineages. The extent and form of reproductive isolation among interacting lineages varies across species, ranging from random admixture to speciation, in one case via reinforcement. Comparative phylogeographic studies, combined with environmental analysis at a fine-scale and across varying climates, can generate new insights into suture zone formation and to diversification processes in species-rich tropical rainforests. As arenas for evolutionary experimentation, suture zones merit special attention for conservation. PMID:19203915

  7. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    Science.gov (United States)

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Augmentation of tendon healing with butyric acid-impregnated sutures: biomechanical evaluation in a rabbit model.

    Science.gov (United States)

    Leek, Bryan T; Tasto, James P; Tibor, Lisa M; Healey, Robert M; Freemont, Anthony; Linn, Michael S; Chase, Derek E; Amiel, David

    2012-08-01

    Butyric acid (BA) has been shown to be angiogenic and to enhance transcriptional activity in tissue. These properties of BA have the potential to augment biological healing of a repaired tendon. To evaluate this possibility both biomechanically and histologically in an animal tendon repair model. Controlled laboratory study. A rabbit Achilles tendon healing model was used to evaluate the biomechanical strength and histological properties at 6 and 12 weeks after repair. Unilateral tendon defects were created in the middle bundle of the Achilles tendon of each rabbit, which were repaired equivalently with either Ultrabraid BA-impregnated sutures or control Ultrabraid sutures. After 6 weeks, BA-impregnated suture repairs had a significantly increased (P Tendons repaired with BA-impregnated sutures demonstrated improved biomechanical properties at 6 weeks relative to control sutures, suggesting a neoangiogenic mechanism of enhanced healing through an increased myofibroblast presence. These findings demonstrate that a relatively simple alteration of suture material may augment early tendon healing to create a stronger repair construct during this time.

  9. A technique for the quantification of the 3D connectivity of thin articulations in bony sutures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Hojjat, Seyed-Parsa; Whyne, Cari M

    2010-04-19

    The anatomy and development of cranial and facial sutures have been studied in detail using histological sections, 2D radiographs and more recently CT imaging. However, little attention has been paid to evaluating and quantifying the connectivity of these thin cortical bone articulations. More recent technological advances such as micro-CT imaging has the potential to be used to provide quantitative measurements of 3D connectivity in bony articulations. This study presents a new technique for quantifying the connectivity of bony projections inside cranial and facial sutures using a combination of skeletonization, thinning algorithms and 3D intensity mapping. The technique is demonstrated in five sutures through semi-automated analysis and image processing of microCT scans. In the sagittal, coronal and frontozygomatic sutures an average bone connectivity of 6.6-11.6% was found with multiple bony projections providing an interlocking structure between adjacent bones. Much higher bone connectivity was present in the zygomaticotemporal and zygomaticomaxillary sutures (22.7-37.4%) with few bony projections. This method combining microCT scanning and image processing techniques was successfully used to quantify the connectivity of thin bone articulations and allowed detailed assessment of sutural fusion in 3D. The wider application of this technique may allow quantification of connectivity in other structures, in particular fracture healing of long bones. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.

    Science.gov (United States)

    Geiger, Madeleine; Haussman, Sinah

    2016-04-01

    Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. © 2016 Wiley Periodicals, Inc.

  11. Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing

    Science.gov (United States)

    Malik, I. A.; Mirkhalaf, M.; Barthelat, F.

    2017-05-01

    Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.

  12. Posterior atlantoaxial dislocation without odontoid fracture

    International Nuclear Information System (INIS)

    Chaudhary, Reema; Raut, Abhijit; Chaudhary, Kshitij; Metkar, Umesh; Rathod, Ashok; Sanghvi, Darshana

    2008-01-01

    We report a case of posterior atlantoaxial dislocation without a fracture of the odontoid in a 35-year-old woman. There have been nine reported cases of similar injury in the English literature. The integrity of the transverse ligament following posterior atlantoaxial dislocations has not been well documented in these reports. In the present case, MRI revealed an intact transverse ligament, which probably contributed to the stability of the C1-C2 complex following closed reduction. (orig.)

  13. Posterior amorphous corneal dystrophy: case report

    OpenAIRE

    Oliveira, Lauro Augusto de [UNIFESP; Vieira, Luiz Antônio [UNIFESP; Freitas, Denise de [UNIFESP; Sousa, Luciene Barbosa de [UNIFESP

    2006-01-01

    O objetivo deste trabalho é alertar o oftalmologista da possibilidade de se deparar com casos raros de distrofias corneanas. Neste caso correlacionamos os achados clínicos da distrofia amorfa posterior com refração, topografia e biomicroscopia ultra-sônica.The purpose of this paper is to warn the ophthalmologist about the possibility of facing rare cases of corneal dystrophies. Clinical findings of a case of posterior amorphous dystrophy were correlated with refraction, topography, and ultras...

  14. Vermian agenesis without posterior fossa cyst

    International Nuclear Information System (INIS)

    Adamsbaum, C.; Moreau, V.; Bulteau, C.; Burstyn, J.; Lair Milan, F.; Kalifa, G.

    1994-01-01

    We report 11 cases of vermian partial agenesis without posterior fossa cyst or hemispheric abnormalities. Characteristic MR signs were: absence of the posterior lobe, hypoplasia of the anterior lobe, a narrow sagittal cleft separating the hemispheres (''buttocks sign'') and fourth ventricle deformity. The main clinical signs were complex oculomotor dysfunction and developmental delay. None of the patients had respiratory symptoms. Consideration is given to the relationship between Joubert syndrome and this entity as well as to embroyological data. (orig.)

  15. Mature teratoma of the posterior mediastinum

    Energy Technology Data Exchange (ETDEWEB)

    Kurosaki, Y.; Tanaka, Y.O.; Itai, Y. [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki-ken 305 (Japan)

    1998-02-01

    The vast majority of germ cell tumors in the thorax arise at or near the thymus. We report a case of a 41-year-old man with mature teratoma of the posterior mediastinum. He was asymptomatic and was incidentally found to have a posterior mediastinal mass. Computed tomography was helpful in suggesting a diagnosis of mature teratoma by demonstrating the presence of fat and calcification. The differential diagnosis included neurogenic tumors, liposarcoma, and extramedullary hematopoiesis. (orig.) With 2 figs., 18 refs.

  16. Mature teratoma of the posterior mediastinum

    International Nuclear Information System (INIS)

    Kurosaki, Y.; Tanaka, Y.O.; Itai, Y.

    1998-01-01

    The vast majority of germ cell tumors in the thorax arise at or near the thymus. We report a case of a 41-year-old man with mature teratoma of the posterior mediastinum. He was asymptomatic and was incidentally found to have a posterior mediastinal mass. Computed tomography was helpful in suggesting a diagnosis of mature teratoma by demonstrating the presence of fat and calcification. The differential diagnosis included neurogenic tumors, liposarcoma, and extramedullary hematopoiesis. (orig.)

  17. An unusual cause of posterior mediastinal cyst

    Directory of Open Access Journals (Sweden)

    Sahajal Dhooria

    2015-01-01

    Full Text Available Cystic lesions of the mediastinum may be congenital or acquired. The differential diagnosis depends on their location in the mediastinum. Cysts in the posterior mediastinum are generally developmental cysts and are neurogenic or of foregut origin. We report the case of a 14-year-old boy, who presented with dry cough and progressively increasing breathlessness, and was found to have a cystic lesion in the posterior mediastinum. Fine needle aspiration from the cyst helped make a diagnosis of tuberculosis.

  18. Analytic posteriors for Pearson's correlation coefficient.

    Science.gov (United States)

    Ly, Alexander; Marsman, Maarten; Wagenmakers, Eric-Jan

    2018-02-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open-source software package JASP.

  19. Analytic posteriors for Pearson's correlation coefficient

    OpenAIRE

    Ly, A.; Marsman, M.; Wagenmakers, E.-J.

    2018-01-01

    Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open‐source software package JASP.

  20. Post-partum posterior reversible encephalopathy syndrome

    OpenAIRE

    B. V. Triveni; Salman Mohammed Sheikh; Deepak Shedde

    2014-01-01

    Posterior Reversible Encephalopathy Syndrome (PRES) is a clinicopathological syndrome associated with various clinical conditions presenting with headache, encephalopathy, seizure and cortical visual disturbances. Radiological findings in PRES are thought to be due to vasogenic edema predominantly in posterior cerebral hemispheres and are reversible with appropriate management. We present a case of post partum PRES,A 29 year old primigravida of 33 weeks 3 days period of gestation who prese...

  1. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  2. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  3. Single wire drift chamber design

    International Nuclear Information System (INIS)

    Krider, J.

    1987-01-01

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 μm rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles

  4. Delayed Single Stage Perineal Posterior Urethroplasty

    International Nuclear Information System (INIS)

    Ali, S.; Shahnawaz; Shahzad, I.; Baloch, M. U.

    2015-01-01

    Objective: To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Study Design: Descriptive case series. Place and Duration of Study: Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Methodology: Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Results: Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patients age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3 percentage) experienced recurrent stricture during first 10 months. Five (16.6 percentage) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6 percentage) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3 percentage with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Conclusion: Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures. (author)

  5. Delayed Single Stage Perineal Posterior Urethroplasty.

    Science.gov (United States)

    Ali, Shahzad; Shahnawaz; Shahzad, Iqbal; Baloch, Muhammad Umar

    2015-06-01

    To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Descriptive case series. Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patient's age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3%) experienced recurrent stricture during first 10 months. Five (16.6%) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6%) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3% with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures.

  6. Early endoscopic realignment in posterior urethral injuries.

    Science.gov (United States)

    Shrestha, B; Baidya, J L

    2013-01-01

    Posterior urethral injury requires meticulous tertiary care and optimum expertise to manage successfully. The aim of our study is to describe our experiences with pelvic injuries involving posterior urethra and their outcome after early endoscopic realignment. A prospective study was carried out in 20 patients with complete posterior urethral rupture, from November 2007 till October 2010. They presented with blunt traumatic pelvic fracture and underwent primary realignment of posterior urethra in our institute. The definitive diagnosis of urethral rupture was made after retrograde urethrography and antegrade urethrography where applicable. The initial management was suprapubic catheter insertion after primary trauma management in casualty. After a week of conservative management with intravenous antibiotics and pain management, patients were subjected to the endoscopic realignment. The follow up period was at least six months. The results were analyzed with SPSS software. After endoscopic realignment, all patients were advised CISC for the initial 3 months. All patients voided well after three months of CISC. However, 12 patients were lost to follow up by the end of 6 postoperative months. Out of eight remaining patients, two had features of restricture and were managed with DVU followed by CISC again. One patient with restricture had some degree of erectile dysfunction who improved significantly after phospodiesterase inhibitors. None of the patients had features of incontinence. Early endoscopic realignment of posterior urethra is a minimally invasive modality in the management of complete posterior urethral injury with low rates of incontinence and impotency.

  7. Traumatic lesions of the posterior urethra.

    Science.gov (United States)

    Velarde-Ramos, L; Gómez-Illanes, R; Campos-Juanatey, F; Portillo-Martín, J A

    2016-11-01

    The posterior urethral lesions are associated with pelvis fractures in 5-10% of cases. The posterior urethra is attached to the pelvis bone by puboprostatic ligaments and the perineal membrane, which explains why disruption of the pelvic ring can injure the urethra at this level. To identify suspected cases of posterior urethral trauma and to perform the diagnosis and its immediate or deferred management. Search in PubMed of articles related to traumatic posterior urethral lesions, written in English or Spanish. We reviewed the relevant publications including literature reviews and chapters from books related to the topic. With patients with pelvis fractures, we must always rule out posterior urethral lesions. The diagnostic examination of choice is retrograde urethrography, which, along with the severity of the condition, will determine the management in the acute phase and whether the treatment will be performed immediately or deferred. Early diagnosis and proper acute management decrease the associated complications, such as strictures, urinary incontinence and erectile dysfunction. Despite the classical association between posterior urethral lesions and pelvic fractures, the management of those lesions (whether immediate or deferred) remains controversial. Thanks to the growing interest in urethral disease, there are an increasing number of studies that help us achieve better management of these lesions. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. MPS II drift chamber system

    International Nuclear Information System (INIS)

    Platner, E.D.

    1982-01-01

    The MPS II detectors are narrow drift space chambers designed for high position resolution in a magnetic field and in a very high particle flux environment. Central to this implementation was the development of 3 multi-channel custom IC's and one multi-channel hybrid. The system is deadtimeless and requires no corrections on an anode-to-anode basis. Operational experience and relevance to ISABELLE detectors is discussed

  9. Short- and long-term results of chordal reconstruction using artificial suture material (polytetrafluoroethylene and polypropylene in the dog

    Directory of Open Access Journals (Sweden)

    Isamu Kanemoto

    2017-04-01

    Full Text Available No previous reports have compared the suitability of expanded polytetrafluoroethylene (ePTFE and polypropylene as artificial suture materials for chordal reconstruction in mitral valve plasty (MVP in the dog. Twelve normal dogs were subjected to MVP using surfaceinduced deep hypothermia. In the short-term group (1.5-4 months after surgery, all ePTFE sutures were covered by a tissue sheath including the paired suture arms, which gave the appearance of native chordae from 2 months after surgery. In contrast, all polypropylene sutures were not covered by tissue, and appeared the same as the paired polypropylene suture arms at the operation. In the long-term group (12 months after surgery, all ePTFE sutures were covered by a tissue sheath, which appeared the same as that in the short-term group, and had flexibility without increased thickness with time. In contrast, although the polypropylene suture was covered completely by a tissue sheath in 1 dog, all the other polypropylene sutures were exposed except for both ends of the suture. ePTFE may be superior to polypropylene as an artificial suture material for chordal reconstruction in MVP.

  10. GBO RF Anechoic Chamber & Antenna Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  11. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  12. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  13. Echocardiographic Wall Motion Abnormality in Posterior Myocardial Infarction: The Diagnostic Value of Posterior Leads

    Directory of Open Access Journals (Sweden)

    A Darehzereshki

    2008-06-01

    Full Text Available Background: For the purpose of ascertaining myocardial infarction (MI and ischemia, the sensitivity of the initial 12-lead ECG is inadequate. It is risky to diagnose posterior MI using only precordial reciprocal changes, since the other leads may be more optimally positioned for the identification of electrocardiographic changes. In this study, we evaluated the relationship between electrocardiography changes and wall motion abnormalities in patients with posterior MI for earlier and better diagnosis of posterior MI.Methods: In this prospective cross-sectional study, we enrolled patients with posterior MI who had come to the Emergency Department of Shariati Hospital with their first episode of chest pain. A 12-lead surface electrocardiogram using posterior leads (V7-V9 was performed for all participants. Patients with ST elevation >0.05 mV or pathologic Q wave in the posterior leads, as well as those with specific changes indicating posterior MI in V1-V2, were evaluated by echocardiography in terms of wall motion abnormalities. All data were analyzed using SPSS and p<0.05 were considered statistically significant.Results: Of a total 79 patients enrolled, 48 (60.8% were men, and the mean age was 57.35±8.22 years. Smoking (54.4% and diabetes (48% were the most prevalent risk factors. In the echocardiographic evaluation, all patients had wall motion abnormalities in the left ventricle and 19 patients (24.1% had wall motion abnormalities in the right ventricle. The most frequent segment with motion abnormality among the all patients was the mid-posterior. The posterior leads showed better positive predictive value than the anterior leads for posterior wall motion abnormality.Conclusion: Electrocardiography of the posterior leads in patients with acute chest pain can help in earlier diagnosis and in time treatment of posterior MI.

  14. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  15. Percutaneous suprapubic stone extraction for posterior urethral stones in children: efficacy and safety.

    Science.gov (United States)

    Safwat, Ahmed S; Hameed, Diaa A; Elgammal, Mohamed A; Abdelsalam, Yasser M; Abolyosr, Ahmad

    2013-08-01

    To evaluate the safety and efficacy of percutaneous suprapubic stone extraction (PSPSE) for pediatric posterior urethral stones. Between July 2007 and June 2010, 54 boys presenting with acute urinary retention due to posterior urethral stones underwent PSPSE. Patients were a mean age of 66.4 months (range, 8-180 months). The stone size was 0.7-1.9 cm. Patients were placed under general anesthesia, and a 7F urethroscope was used to pushback the stone to the bladder. A 3-mm suprapubic puncture with a scalpel was performed, followed by insertion of a straight narrow hemostat through the puncture aided with cystoscopic guidance. The stone was grasped with the hemostat in its narrowest diameter and was extracted percutaneously or crushed if friable. The suprapubic puncture was closed with a single 4-0 Vicryl (Ethicon) suture. Intact stone retrieval was achieved in 45 patients, and the stone was crushed into minute fragments in 9 patients. Intraperitoneal extravasation developed in 1 patient that required open surgical intervention. Mean operative time was 22 minutes. Patients were monitored for up to 17 months, with complete resolution of symptoms and stone clearance. PSPSE provides a minimally invasive approach for the extraction of urethral and bladder stones in the pediatric population. The use of a straight hemostat for suprapubic stone extraction or crushing is a good alternative to suprapubic tract dilation, with minimal morbidity. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  17. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  18. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  19. Sensitivity of gaseous xenon ionisation chambers (1961)

    International Nuclear Information System (INIS)

    Schuhl, C.

    1960-01-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [fr

  20. Comparison of Tibiofemoral Contact Mechanics After Various Transtibial and All-Inside Fixation Techniques for Medial Meniscus Posterior Root Radial Tears in a Porcine Model.

    Science.gov (United States)

    Chung, Kyu Sung; Choi, Choong Hyeok; Bae, Tae Soo; Ha, Jeong Ku; Jun, Dal Jae; Wang, Joon Ho; Kim, Jin Goo

    2018-04-01

    To compare tibiofemoral contact mechanics after fixation for medial meniscus posterior root radial tears (MMPRTs). Seven fresh knees from mature pigs were used. Each knee was tested under 5 conditions: normal knee, MMPRT, pullout fixation with simple sutures, fixation with modified Mason-Allen sutures, and all-inside fixation using Fastfix 360. The peak contact pressure and contact surface area were evaluated using a capacitive sensor positioned between the meniscus and tibial plateau, under a 1,000-N compression force, at different flexion angles (0°, 30°, 60°, and 90°). The peak contact pressure was significantly higher in MMPRTs than in normal knees (P = .018). Although the peak contact pressure decreased significantly after fixation at all flexion angles (P = .031), it never recovered to the values noted in the normal meniscus. No difference was observed among fixation groups (P = .054). The contact surface area was significantly lower in MMPRTs than in the normal meniscus (P = .018) and increased significantly after fixation at all flexion angles (P = .018) but did not recover to within normal limits. For all flexion angles except 60°, the contact surface area was significantly higher for fixation with Mason-Allen sutures than for fixation with simple sutures or all-inside fixation (P = .027). At 90° of flexion, the contact surface area was significantly better for fixation with simple sutures than for all-inside fixation (P = .031). The peak contact pressure and contact surface area improved significantly after fixation, regardless of the fixation method, but did not recover to the levels noted in the normal meniscus after any type of fixation. Among the fixation methods evaluated in this time 0 study, fixation using modified Mason-Allen sutures provided a superior contact surface area compared with that noted after fixation using simple sutures or all-inside fixation, except at 60° of flexion. However, this study had insufficient power to

  1. Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.

    Science.gov (United States)

    Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D

    We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Proportional chambers and multiwire drift chambers at high rates

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1977-01-01

    The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem

  3. Outcomes of the modified Brostrom procedure using suture anchors for chronic lateral ankle instability--a prospective, randomized comparison between single and double suture anchors.

    Science.gov (United States)

    Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin

    2013-01-01

    The present prospective, randomized study was conducted to compare the clinical outcomes of the modified Brostrom procedure using single and double suture anchors for chronic lateral ankle instability. A total of 50 patients were followed up for more than 2 years after undergoing the modified Brostrom procedure. Of the 50 procedures, 25 each were performed using single and double suture anchors by 1 surgeon. The Karlsson scale had improved significantly to 89.8 points and 90.6 points in the single and double anchor groups, respectively. Using the Sefton grading system, 23 cases (92%) in the single anchor group and 22 (88%) in the double anchor group achieved satisfactory results. The talar tilt angle and anterior talar translation on stress radiographs using the Telos device had improved significantly to an average of 5.7° and 4.6 mm in the single anchor group and 4.5° and 4.3 mm in the double anchor group, respectively. The double anchor technique was superior with respect to the postoperative talar tilt. The single and double suture anchor techniques produced similar clinical and functional outcomes, with the exception of talar tilt as a reference of mechanical stability. The modified Brostrom procedure using both single and double suture anchors appears to be an effective treatment method for chronic lateral ankle instability. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Towards a viscoelastic model for the unfused midpalatal suture: development and validation using the midsagittal suture in New Zealand white rabbits.

    Science.gov (United States)

    Romanyk, D L; Liu, S S; Lipsett, M G; Toogood, R W; Lagravère, M O; Major, P W; Carey, J P

    2013-06-21

    Maxillary expansion treatment is a commonly used procedure by orthodontists to widen a patient's upper jaw. As this is typically performed in adolescent patients, the midpalatal suture, connective tissue adjoining the two maxilla halves, remains unfused. Studies that have investigated patient response to expansion treatment, generally through finite element analysis, have considered this suture to behave in a linear elastic manner or it was left vacant. The purpose of the study presented here was to develop a model that could represent the midpalatal suture's viscoelastic behavior. Quasilinear viscoelastic, modified superposition, Schapery's, and Burgers modeling approaches were all considered. Raw data from a previously published study using New Zealand White Rabbits was utilized for model parameter estimation and validation. In this study, Sentalloy(®) coil springs at load levels of 0.49N (50g), 0.98N (100g), and 1.96N (200g) were used to widen the midsagittal suture of live rabbits over a period of 6 weeks. Evaluation was based on a models ability to represent experimental data well over all three load sets. Ideally, a single set of model constants could be used to represent data over all loads tested. Upon completion of the analysis it was found that the modified superposition method was able to replicate experimental data within one standard deviation of the means using a single set of constants for all loads. Future work should focus on model improvement as well as prediction of treatment outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Biomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Virk, Mandeep S; Bruce, Benjamin; Hussey, Kristen E; Thomas, Jacqueline M; Luthringer, Tyler A; Shewman, Elizabeth F; Wang, Vincent M; Verma, Nikhil N; Romeo, Anthony A; Cole, Brian J

    2017-02-01

    To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row sutures were passed either near the MTJ (MTJ group) or 10 mm lateral to the MTJ (rotator cuff tendon [RCT] group). After the supraspinatus repair, the specimens underwent cyclic loading and load to failure tests. The localized displacement of the markers affixed to the tendon surface was measured with an optical tracking system. The MTJ group showed a significantly higher (P = .03) medial row failure (5/9; 3 during cyclic testing and 2 during load to failure testing) compared with the RCT group (0/9). The mean number of cycles completed during cyclic testing was lower in the MTJ group (77) compared with the RCT group (100; P = .07) because 3 specimens failed in the MTJ group during cyclic loading. There were no significant differences between the 2 study groups with respect to biomechanical properties during the load to failure testing. In a cadaveric TOE-SB DR RCR model, medial row sutures through the MTJ results in a significantly higher rate of medial row failure. In rotator cuff tears with tendon tissue loss, passage of medial row sutures through the MTJ should be avoided in a TOE-SB RCR technique because of the risk of medial row failure. Copyright © 2016. Published by Elsevier Inc.

  6. The B-Lynch uterine brace suture, and a bit of this and a bit of that...

    Science.gov (United States)

    Karoshi, Mahantesh

    2010-03-01

    The widespread application of the B-Lynch brace suture to control postpartum hemorrhage has sparked interest in a variety of adjunctive methods, used alone or in combination, to control uterine bleeding. Although the B-Lynch brace suture has been used with good results throughout the world, failures can and do occur in rare instances, especially when the suture is incorrectly placed for use for an inappropriate indication. Four reports of additional methods to control postpartum hemorrhage are published in this issue of IJGO. Three use the B-Lynch brace suture combined with other techniques. The need for additional techniques reminds the reader of the importance of proper suture application for proper indication. Potential reasons for failure of the B-Lynch suture are provided.

  7. Influence of suturing material on wound healing: Experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Gazivoda Dragan

    2015-01-01

    Full Text Available Background/Aim. The most common materials implanted in the human organism are suture materials that are classified on the basis of several criteria, usually the origin, structure, and properties. The properties of suture materials are related to its absorbability and non-absorbability. When using resorbable materials it is of great importance to determine whether its absorbability and tensile strength help wound healing in function of time. Sutures themselves can become a source of inflammation, that may reduce or compromise the potential of reparation and regeneration. The aim of this experimental study on dogs was to ascertain whether the absorption rate and the degree of local tissue reactions differ from information provided by the manufacturers, whether there are differences between the applied suture materials and which of the used suture materials have better effect on wound healing. Methods. Experimental testing of the selected suture materials basic characteristics was performed on 6 German Shepherd dogs, which, after induction of general anesthesia, were made 3 identical incisions each in all 4 quadrants (left and right side of the upper and lower jaws, so that 12 horizontal incisions were formed, 10 mm long, 20-25 mm distant from one another, on each animal. Randomly, incisions were stitched up in the following order, starting from back to front: catgut, Dexon®, Vicryl-Rapid®. The experiment was terminated by histopathological examination of tissue samples, taken on postoperative day 3, 7, 14 and 21 in order to identify the effect of healing and the degree of local reaction. Results. The obtained results suggest that catgut has the highest absorption rate, while Dexon® the lowest. Vicryl-Rapid® causes the lowest level of local reactions, while Dexon® the highest. Conclusion. There is no ideal suture material because various patient factors also influence the wound healing process.

  8. Biomechanical analysis of suture locations of the distal plantar fascia in partial foot.

    Science.gov (United States)

    Guo, Jun-Chao; Wang, Li-Zhen; Mo, Zhong-Jun; Chen, Wei; Fan, Yu-Bo

    2015-12-01

    The aim of this study was to evaluate the rationality of the suture locations of distal plantar fascia (DPF) after foot amputation to avoid the risk factors of re-amputation or plantar fasciitis. The tensile strain of plantar fascia (PF) in the different regions was measured by uni-axial tensile experiment. A three-dimensional (3D) finite element model was also developed to simulate tensile behaviour of PF in weight bearing conditions. The model includes 12 bones, ligaments, PF, cartilage and soft tissues. Four suture location models for the DPF were considered: the fourth and fifth DPF were sutured on the third metatarsal, the cuboid, and both the third metatarsal and the cuboid, and one un-sutured model. The peak tensile strain of the first, second and third PF was 0.134, 0.128 and 0.138 based on the mechanical test, respectively. The fourth and fifth DPF sutured at the cuboid and the third metatarsal could offer more favourable outcomes. The peak strain of 4.859 × 10(-2), 2.347 × 10(-2) and 1.364 × 10(-2) in the first, second and third PF showed the least outcomes in stance phase. Also, peak strain and stress of the residual PF reduced to 4.859 × 10(-2) and 1.834 MPa, respectively. The stress region was redistributed on the mid-shaft of the first and third PF and the peak stress of medial cuneiform bone evidently decreased. The fourth and fifth DPF suture at the third metatarsal and cuboid was appropriate for the partial foot. The findings are expected to suggest optimal surgical plan of the DPF suture and guide further therapeutic planning of partial foot patients.

  9. Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth.

    Directory of Open Access Journals (Sweden)

    R Nicole Howie

    Full Text Available Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs. Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day. Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic. High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology.

  10. Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth.

    Science.gov (United States)

    Howie, R Nicole; Durham, Emily L; Black, Laurel; Bennfors, Grace; Parsons, Trish E; Elsalanty, Mohammed E; Yu, Jack C; Weinberg, Seth M; Cray, James J

    2016-01-01

    Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease) are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures) prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs). Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day). Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic). High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology.

  11. Comparison of efficacy of polypropylene with chromic catgut suture in stitching paediatric facial lacerations

    International Nuclear Information System (INIS)

    Hussain, A.; Ahmed, R.; Aziz, O.B.A.; Aamir, M.

    2016-01-01

    Objective: The objective of this study was to compare 5/0 polypropylene suture with 5/0 chromic catgut in small clean pediatric facial laceration repair in terms of cosmetic outcome. Study Design: Randomized controlled trial.Place and Duration of Study: Combined Military Hospital, Rawalpindi from 26th May 2012 to 25th Nov 2012.Patients and Methods: A total of 300 patients of both gender under 12 years of age, with small clean facial lacerations were selected and divided in two equal groups using random number tables. All the patients underwent suturing in minor operating theater of trauma centre CMH Rawalpindi as day care cases, under local anesthesia and aseptic measures. In group 1, polypropylene 5/0 suture was used where as in group 2 chromic catgut 5/0 was used for suturing. Aseptic dressing was applied. All patients were reviewed on 5th day (for stitch removal in polypropylene group) and 3 months post-operatively to establish cosmetic outcome which was determined by scar visual analog score both by parents of the child and consultant surgeon. Results: The mean VAS (visual analog score) as observed by Consultant surgeon was 79.14 and 78.63 for polypropylene and chromic catgut groups respectively. The mean VAS observed by the parents of the child for respective groups was 76.67 and 76.03. The significance value was 0.961 for parental VAS and 0.988 for surgeons VAS depicting insignificant difference in both suture groups.Conclusion: There is no long-term difference in cosmetic outcomes of both the sutures in the repair of facial lacerations in the pediatric population. No difference in complication rate of wound was observed. In addition, the parents of the children in absorbable suture group expressed satisfaction over prevention of psychological trauma of stitch removal. (author)

  12. Randomized clinical trial comparing cold knife conization of the cervix with and without lateral hemostatic sutures.

    Science.gov (United States)

    Bueno, Letícia Rossi; Binda, Marcia; Monego, Heleusa; Scherer, Roberta Luísa; Rolim, Karen Machado; Bottini, Alessandra Leal; Fregnani, José H T G; dos Reis, Ricardo

    2015-06-01

    Compare blood loss during cold knife conization of the cervix with and without lateral hemostatic sutures in the cervical branches of the uterine arteries. Randomized clinical trial. Hospital de Clínicas de Porto Alegre (HCPA). 102 patients that underwent cold knife conization. Women that underwent cold knife conization of the cervix were randomized to undergo the procedure with or without lateral hemostatic sutures. blood loss measured in grams. operative time and postoperative intervention. Only the participants were blinded to group assignment. From March 2009 to August 2012, patients were randomly assigned to one of the study groups. There were no differences in amount of blood loss between patients that underwent the procedure with and without sutures (p = 0.39). Operative time was shorter in the group without suture (p = 0.020). There were no differences in intervention due to bleeding (p = 0.20). Blood loss was greater among menstruating women than for menopausal women (p = 0.011). There were no differences in amount of blood lost between smoking and nonsmoking patients (p = 0.082). Lateral hemostatic sutures do not affect the amount of intraoperative bleeding or the number of postoperative interventions. Their use is not necessary because they result in longer operative time, have a higher cost due to the use of suture material and pose the risk of ureter lesion in case the sutures are not placed at a lower position in the cervix. ClinicalTrials. gov identifier: NCT02184975. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  13. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London...

  14. Proceedings of workshop on streamer chamber

    International Nuclear Information System (INIS)

    Itoh, Hidihiko; Takahashi, Kaoru; Hirose, Tachishige; Masaike, Akira

    1978-08-01

    For high accuracy observation of multiple-body reactions, a vertex detector of high efficiency is essential. A bubble chamber, though excellent for tracks detection, is problematic in statistics accuracy. The vertex detector with a wire chamber, while better in this respect, difficult in multiple-particle detection etc. The workshop has had several meetings on a streamer chamber as a detector combining features of both bubble chamber and counter, with emphasis on tracks observation in avalanche mode and recordings not using films. Contents are on streamer chamber gas, analytical photography, data processing, simulation program, etc. (Mori, K.)

  15. Management of posterior urethral disruption injuries.

    Science.gov (United States)

    Myers, Jeremy B; McAninch, Jack W

    2009-03-01

    Posterior urethral disruption is a traumatic injury to the male urethra, which most often results from pelvic fracture. After trauma, the distraction defect between the two ends of the urethra often scars and becomes fibrotic, blocking the urethra and bladder emptying. Increasing evidence suggests that many posterior urethral disruptions occur at the junction between the membranous urethra and the bulbar urethra, which is distal to the rhabdosphincter. In the acute setting, when a posterior urethral disruption is suspected, retrograde urethrography should be performed. Posterior urethral disruptions can be managed acutely by realignment of the urethra over a urethral catheter or by placement of a suprapubic catheter for bladder drainage only. Once fibrosis has stabilized, the patient can undergo posterior urethroplasty. In most cases, this procedure can be performed via a perineal approach in a single-stage surgery. The results of this single-stage perineal urethroplasty are excellent, and a patent urethra can be re-established in the majority of men who undergo surgery.

  16. A prospective outcome and cost-effectiveness comparison between two ligament reattachment techniques using suture anchors for chronic ankle instability.

    Science.gov (United States)

    Cho, Byung-Ki; Kim, Yong-Min; Park, Kyoung-Jin; Park, Ji-Kang; Kim, Do-Kyoon

    2015-02-01

    There are various ligament reattachment techniques for the modified Brostrom procedure. There have been few comparative studies on recently developed techniques. This prospective study was performed to compare the functional outcomes of 2 different ligament reattachment techniques using suture anchors. We furthermore evaluated the cost-effectiveness of the suture bridge technique. Forty-five amateur athletes under 30 years of age were followed for more than 2 years. Twenty-four procedures with the suture anchor technique and 21 procedures with the suture bridge technique were performed by one surgeon. The functional evaluation consisted of the American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Outcome Score (FAOS), Karlsson score, Sefton grading system, and the period to return to various forms of exercise (jogging, spurt running, jumping, one leg standing for >1 minute, walking on uneven ground, and going down stairs). Measurement of talar tilt angle and anterior talar translation was obtained from stress radiographs to evaluate mechanical stability. There were no significant differences on AOFAS score, FAOS, Karlsson score, Sefton grade, and stress radiographs. There were no significant differences on the return to exercises, except for jumping. As the most common complication, there were 3 cases of skin irritation by suture materials in the suture anchor group and 2 cases of intraoperative breakage of the suture anchor in suture bridge group. Both ligament reattachment techniques using suture anchors showed similar functional outcomes. Considering the additional medical expenses incurred by more suture anchors, the modified Brostrom procedure using the suture bridge technique had low cost-effectiveness. Proper indication and clinical usefulness of suture bridge technique for chronic ankle instability will be addressed in further studies. Level II, prospective comparative study. © The Author(s) 2014.

  17. The efficacy of laparoscopic intracorporeal linear suture technique as a strategy for reducing recurrences in pediatric inguinal hernia.

    Science.gov (United States)

    Lee, S R; Choi, S B

    2017-06-01

    Pediatric laparoscopic herniorrhaphy has rare complications, but recurrence might occur. The purpose of this manuscript is to evaluate the efficacy of linear suture technique of laparoscopic pediatric herniorrhaphy in reducing recurrences. Laparoscopic surgery was performed on 2223 pediatric patients (under 10 years old) from September 2012 to December 2014 in Damsoyu Hospital, Seoul, Republic of Korea. The causes of recurrence were investigated case by case. The patients were categorized into two groups according to the suture method used in closing the hernia orifice: Group 1 (purse-string suture, 1009 patients) and Group 2 (linear suture, 1214 patients). There were 1413 (63.6%) male and 810 (36.4%) female patients. Mean age was 30.5 ± 29.2 months. A significantly higher proportion of male patients, contralateral patent processus vaginalis, and less proportion of recurrence were observed in Group 2. There were ten cases of recurrence in Group 1 because the internal ring suture could not endure the tension. One recurrence occurred in Group 2. The suture technique and age were found to be a significant risk factor for recurrence. Linear suture technique had a lower recurrence rate (odds ratio = 0.07, with 95% confidence interval 0.01-0.53, and p = 0.004). Purse-string suture technique causes significantly higher occurrence of hernia recurrences than linear suture technique. Linear suture technique can reduce recurrence by increasing the endurance to tension around the internal ring by distributing pressure to a wider area along the linear suture line. Linear suture technique can effectively reduce recurrence in pediatric inguinal herniorrhaphy.

  18. Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).

    Science.gov (United States)

    von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel

    2008-04-01

    The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.

  19. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1995-01-01

    Chamber transport is an important area of study for heavy ion fusion. Final focus and chamber-transport are high leverage areas providing opportunities to significantly decrease the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (approx-lt 0.003 torr), ballistic or nearly-ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (approx-gt.1 torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber then transporting it at small radius (∼ 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity

  20. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1996-01-01

    Chamber transport is a key area of study for heavy ion fusion. Final focus and chamber transport are high leverage areas providing opportunities to decrease significantly the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (below about 0.003 Torr), ballistic or nearly ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (above about 0.1 Torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber and then transporting it at small radius (about 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity. (orig.)

  1. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  2. TRU waste characterization chamber gloveboxes

    International Nuclear Information System (INIS)

    Duncan, D. S.

    1998-01-01

    Argonne National Laboratory-West (ANL-W) is participating in the Department of Energy's (DOE) National Transuranic Waste Program in support of the Waste Isolation Pilot Plant (WIPP). The Laboratory's support currently consists of intrusive characterization of a selected population of drums containing transuranic waste. This characterization is performed in a complex of alpha containment gloveboxes termed the Waste Characterization Gloveboxes. Made up of the Waste Characterization Chamber, Sample Preparation Glovebox, and the Equipment Repair Glovebox, they were designed as a small production characterization facility for support of the Idaho National Engineering and Environmental Laboratory (INEEL). This paper presents salient features of these gloveboxes

  3. Experimental work on drift chambers

    International Nuclear Information System (INIS)

    Alcaraz, J.; Duran, I.; Gonzalez, E.; Martinez-Laso, L.; Olmos, P.

    1989-01-01

    An experimental work made on drift chambers is described in two chapters. In the firt chapter we present the description of the experimental installation used, as well as some details on the data adquisition systems and the characteristics on three ways used for calibration proposes (cosmic muons, β radiation and test beam using SPS at CERN facilities). The second chapter describes the defferent prototypes studied. The experimental set up and the analysis are given. Some results are discussed. The magnetic field effect is also studied. (Author)

  4. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    1979-05-01

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  5. Gnathostomiasis of the anterior chamber

    Directory of Open Access Journals (Sweden)

    Barua P

    2007-01-01

    Full Text Available Ocular involvement with Gnathostoma spinigerum occurs years after the initial infection that is acquired by ingestion of poorly cooked, pickled seafood or water contaminated with third stage larvae. Here we report a case of gnathostomiasis of the left eye of a 32-year-old lady hailing from Meghalaya, India. Her vision had deteriorated to hand movement. Slit lamp examination revealed a live, actively motile worm in the anterior chamber, which was extracted by supra temporal limbal incision and visual acuity was restored.

  6. Late presentation of posterior urethral valves.

    Science.gov (United States)

    Jalbani, Imran Khan; Biyabani, Syed Raziuddin

    2014-05-01

    Presence of posterior urethral valves (PUV) is the most common cause of urinary tract obstruction in the male neonate. Late presentation occurs in 10% of cases. We present a case of PUVs in an adult male who presented with history of obstructive lower urinary tract symptoms and hematuria. On evaluation, he was found to have raised serum creatinine level. A voiding cystourethrogram (VCUG) could not be completely performed because of narrowing in the posterior urethra. A rigid urethrocystoscopy was performed at which he was found to have type-I posterior urethral valve which were fulgurated. A repeat uroflowmetry revealed maximum flow rate of 12 ml/second. This case highlights that PUVs is not solely a disease of infancy but may also present late. VCUG is the radiological investigation of choice but the diagnosis may be missed. A urethrocystoscopy is advised if there is a high index of suspicion.

  7. The bihemispheric posterior inferior cerebellar artery

    International Nuclear Information System (INIS)

    Cullen, Sean P.; Ozanne, Augustin; Alvarez, Hortensia; Lasjaunias, Pierre

    2005-01-01

    Rarely, a solitary posterior inferior cerebellar artery (PICA) will supply both cerebellar hemispheres. We report four cases of this variant. We present a retrospective review of clinical information and imaging of patients undergoing angiography at our institution to identify patients with a bihemispheric PICA. There were four patients: three males and one female. One patient presented with a ruptured arteriovenous malformation, and one with a ruptured aneurysm. Two patients had normal angiograms. The bihemispheric PICA was an incidental finding in all cases. The bihemispheric vessel arose from the dominant left vertebral artery, and the contralateral posterior inferior cerebellar artery was absent or hypoplastic. In all cases, contralateral cerebellar supply arose from a continuation of the ipsilateral PICA distal to the choroidal point and which crossed the midline dorsal to the vermis. We conclude that the PICA may supply both cerebellar hemispheres. This rare anatomic variant should be considered when evaluating patients with posterior fossa neurovascular disease. (orig.)

  8. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  9. Swimming mechanics and propulsive efficiency in the chambered nautilus

    Science.gov (United States)

    Neil, Thomas R.; Askew, Graham N.

    2018-02-01

    The chambered nautilus (Nautilus pompilius) encounters severe environmental hypoxia during diurnal vertical movements in the ocean. The metabolic cost of locomotion (Cmet) and swimming performance depend on how efficiently momentum is imparted to the water and how long on-board oxygen stores last. While propulsive efficiency is generally thought to be relatively low in jet propelled animals, the low Cmet in Nautilus indicates that this is not the case. We measured the wake structure in Nautilus during jet propulsion swimming, to determine their propulsive efficiency. Animals swam with either an anterior-first or posterior-first orientation. With increasing swimming speed, whole cycle propulsive efficiency increased during posterior-first swimming but decreased during anterior-first swimming, reaching a maximum of 0.76. The highest propulsive efficiencies were achieved by using an asymmetrical contractile cycle in which the fluid ejection phase was relatively longer than the refilling phase, reducing the volume flow rate of the ejected fluid. Our results demonstrate that a relatively high whole cycle propulsive efficiency underlies the low Cmet in Nautilus, representing a strategy to reduce the metabolic demands in an animal that spends a significant part of its daily life in a hypoxic environment.

  10. Planned posterior assisted levitation in severe subluxated cataract: Surgical technique and clinical results

    Directory of Open Access Journals (Sweden)

    Tova Lifshitz

    2012-01-01

    Full Text Available We report the surgical technique and outcome of planned posterior assisted levitation (P-PAL in four cases of subluxated cataract. P-PAL was planned as the preferred approach in all cases. A spatula was inserted via the pars plana, the whole lens was lifted to the anterior chamber and then removed through a scleral tunnel incision. Anterior chamber intraocular lenses were implanted in all cases. All four eyes had severe subluxation of the crystalline lenses with marked phacodonesis. Two eyes had history of blunt trauma, and the other two eyes had severe pseudoexfoliation with spontaneous lens subluxation. Follow-up ranged from 1 to 2 years in three cases. The postoperative visual acuity was 20/80 or better. No intraoperative complications were observed. In conclusion, the P-PAL technique was successfully performed during cataract surgery in four eyes with severe subluxated cataracts. There were no complications over the long-term follow-up.

  11. Creep rupture behavior of polypropylene suture material and its applications as a time-release mechanism

    International Nuclear Information System (INIS)

    Kusy, R.P.; Whitley, J.Q.

    1983-01-01

    The controlled failure of polypropylene (PP) sutures is studied via creep rupture tests. From plots of log time (tB) vs. stress (sigma), linear relationships are generated over the failure times of 1-1000 h. Results show that as a function of stress, the time dependence varies with irradiation dose (15, 20, 25, and 50 Mrad), irradiation atmosphere (air and vacuum), suture diameter (7-0, 6-0, 5-0, and 4-0), and test temperature (26 and 37 degrees C). For a given stress, the time to failure is least for the greatest dose in the presence of air and at the highest temperature. When suture loops are wrapped around a small wire sheave, however, failure occurs in the largest suture as much as two decades sooner than the smallest suture studied. Within the limitations stated herein, they are independent of test method, loop diameter, aging, and humidity. Consequently, after irradiation in vacuum and postirradiation heat treatment, the processed material may be stored at room temperature for at least 1 month. Such materials are advocated when the time release of a dental or medical device is required, for example, in the self-activating cleft palate appliance

  12. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    Science.gov (United States)

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  13. Effect of the use of carprofen in dogs undergoing intense rehabilitation after lateral fabellar suture stabilization.

    Science.gov (United States)

    Gordon-Evans, Wanda J; Dunning, Diane; Johnson, Ann L; Knap, Kim E

    2011-07-01

    To determine whether carprofen, a commercially available NSAID, would decrease perceived exertion and signs of pain in dogs and therefore increase muscle mass and hind limb function without decreasing range of motion after lateral fabellar suture stabilization. Randomized, blinded, controlled clinical trial. 35 dogs with cranial cruciate ligament rupture and lateral fabellar suture stabilization followed by rehabilitation. All dogs underwent surgical stabilization of cranial cruciate ligament rupture by placement of a lateral fabellar suture. Dogs received carprofen (2.2 mg/kg [1 mg/lb], PO, q 12 h) for the first 7 days after surgery and underwent concentrated rehabilitation exercises during weeks 3, 5, and 7 after surgery. Eighteen dogs also received carprofen (2.2 mg/kg, PO, q 12 h) during the weeks of concentrated rehabilitation. Outcomes were measured by a single investigator, who was blinded to group assignments, using pressure platform gait analysis, goniometry, thigh circumference, and mean workout speed at a consistent level of exertion. There were no differences between the 2 groups in ground reaction forces, thigh circumference, or exertion (mean workout speed) over time or at any individual time point. However, both groups improved significantly over time for all outcome measures. Providing carprofen to dogs during concentrated rehabilitation after lateral fabellar suture stabilization did not improve hind limb function, range of motion, or thigh circumference, nor did it decrease perceived exertion, compared with control dogs. Carprofen was not a compulsory component of a physical therapy regimen after lateral fabellar suture stabilization.

  14. The use of quilting suture in abdominoplasty does not require aspiratory drainage for prevention of seroma.

    Science.gov (United States)

    Arantes, Henrique Lopes; Rosique, Rodrigo Gouvêa; Rosique, Marina Junqueira Ferreira; Mélega, Jose Marcos

    2010-02-01

    The formation of seromas after abdominoplasty is a highly prevalent complication that disturbs both the patient and the surgeon. Aspiratory drainage and adhesion sutures (Baroudi suture) are widely used to prevent this complication. This study evaluated the effectiveness of drains in preventing seromas. This retrospective study investigated women submitted to classic abdominoplasty with adhesion sutures. The women were divided into two groups. Group 1 comprised 28 individuals who received no drains, and group 2 consisted of 32 patients that had drains placed. Clinical evaluation of the patients was performed 7 days, 14 days, 1 month, 2 months, 4 months, and 6 months postoperatively. Statistical analysis was accomplished via Fisher's exact test. Group 1 had one case of seroma (3.5%), clinically detected between the first and second postoperative months, whereas group 2 had one case (3.12%) detected 14 days postoperatively. Fisher's test showed a P value of 1.000 (not statistically significant), for a 95% confidence interval of 0.05 to 14.08 and an odds ratio of 0.8387. Clinical evaluation showed no statistical difference in the incidence of seromas after abdominoplasty with adhesion sutures between the patients who received drains and those who did not. The use of adhesion sutures is an effective measure for preventing seromas with no need for additional surgical measures.

  15. Single-layer versus double-layer laparoscopic intracorporeally sutured gastrointestinal anastomoses in the canine model.

    Science.gov (United States)

    Tavakoli, Azine; Bakhtiari, Jalal; Khalaj, Ali Reza; Gharagozlou, Mohammad Javad; Veshkini, Abbas

    2010-01-01

    The objective of this study was to compare the gross and histopathologic changes following 1- versus 2-layer hand-sewn suture techniques in laparoscopic gastrointestinal anastomosis in dogs. This was an experimental prospective study of 16 healthy mixed breed male and female dogs. Animals were randomly divided into 2 groups. Two-layer side-to-side hand-sewn laparoscopic gastrojejunostomies were performed in group A, so that simple interrupted sutures were placed in the outer layer and simple continuous suture was used in the inner layer. The 1-layer simple continuous anastomosis between the stomach and jejunum was done in group B precisely. Specimen were collected from the sites of anastomosis, and H&E statining was performed for light microscopic studies. All animals survived the surgery. There was no gross inflammation, ischemia, apparent granulation tissue, abscess or fistula formation, leakage or stricture formation, and all sites of anastomosis were patent. Several adhesion formations were found in the abdomen with the higher incidence in the control group. Mean scores of leukocyte infiltration and granulation tissue formation at the sites of anastomosis were statistically insignificant between groups (P>0.05). Gross and histopathologic findings revealed that hand-sewn laparoscopic gastrointestinal anastomosis with the 1-layer suture technique is comparable to the 2-layer suture technique.

  16. Long-term efficacy of anchored barbed sutures in the face and neck.

    Science.gov (United States)

    Kaminer, Michael S; Bogart, Megan; Choi, Christine; Wee, Sue Ann

    2008-08-01

    The thread lift is a minimally invasive procedure that uses barbed sutures, inserted subcutaneously, to produce lifting of ptotic tissue of the face and neck. There are currently very limited data on longevity and patient satisfaction following barbed suture lifting procedures. The purpose of this study was to assess long-term efficacy following the use of barbed sutures. A satisfaction survey was mailed to 20 patients who were a minimum of 6 months (range, 6 to 16 months) postprocedure. Physician assessment of pre- and postprocedure photographs was also performed. At an average of 11.5 months postprocedure, patients felt that the barbed suture lift met their expectations, rating their satisfaction a 6.9 on a scale of 1 to 10. Independent physicians rated the overall improvement an average of 4.6 of 10. Higher scores were noted in Zone 1 (tear trough/malar fat pad and nasolabial folds) compared to Zone 2 (marionette lines, jowls, and jawline definition) and Zone 3 (platysmal bands and neck contour). The barbed suture lift procedure provides moderate long-term and sustained improvement for facial laxity, with most improvement seen in the tear trough/malar fat pads and nasolabial folds. In this study, clinical efficacy was seen up to 16 months postprocedure.

  17. Efficacy of silver coated surgical sutures on bacterial contamination, cellular response and wound healing

    International Nuclear Information System (INIS)

    Gallo, Anna Lucia; Paladini, Federica; Romano, Alessandro; Verri, Tiziano; Quattrini, Angelo; Sannino, Alessandro; Pollini, Mauro

    2016-01-01

    The resistance demonstrated by many microorganisms towards conventional antibiotics has stimulated the interest in alternative antimicrobial agents and in novel approaches for prevention of infections. Silver, a natural braod-spectrum antimicrobial agent known since antiquity, has been widely employed in biomedical field due to its recognized antibacterial, antifungal and antiviral properties. In this work, antibacterial silver coatings were deposited on absorbable surgical sutures through the in situ photo-chemical deposition of silver clusters. Scanning electron microscopy (SEM), Energy dispersive X-ray spectroscopy (EDX) and thermo-gravimetric analysis (TGA) were performed in order to investigate the presence and distribution of the silver clusters on the substrate. The amounts of silver deposited and released by the silver treated sutures were calculated through Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS), and the results were related to the biodegradation of the material. The microbiological properties and the potential cytotoxicity of the silver-treated sutures were investigated in relation with hydrolysis experiments, in order to determine the effect of the degradation on antibacterial properties and biocompatibility. - Highlights: • The in situ photo-deposition of silver nano-coatings was used to develop silver treated PGLA sutures. • The silver particles deposited had good distribution and strong adhesion to the substrate. • The silver treated sutures demonstrated good biocompatibility and antibacterial capability. • The presence of silver promoted cell migration and proliferation in the wound area.

  18. The Effect of Suture Anchor Insertion Angle on Calcaneus Pullout Strength: Challenging the Deadman's Angle.

    Science.gov (United States)

    Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K

    2017-10-01

    Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.

  19. Visibility of sutures of the orbit and periorbital region using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gufler, Hubert; Preis, Markus; Koesling, Sabrina [Dept. of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Halle (Germany)

    2014-12-15

    Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube current from 25 to 370 mAs, depending on the CT indication. The visibility of sutures was estimated according to a 4-point scale from 'not visible to well visible' The chi-squared test was used to test the association of the visibility of sutures with the slice thickness, tube current, and age of patients. Statistical significance was assumed at p < 0.05. Overall, best visibility was found for the sutura frontozygomatica (98%), sutura frontonasalis (88.5%), and sutura sphenozygomatica (71.5%), followed by the sutura zygomaticomaxillaris (65.8%), sutura temporozygomatica (41.8%), sutura frontomaxillaris (44.5%), and sutura sphenofrontalis (31%). Poor visibility was found for the sutura frontolacrimalis (16.8%) and sutura frontoethmoidalis (1.3%). The sutura ethmoidomaxillaris, sutura lacrimomaxillaris, and sutura ethmoidolacrimalis were not visible. Although the sutures of the superior, lateral, and inferior orbit are well visible, those of the medial orbit are poorly visible on CT scans.

  20. Comparative Study Between Coaptive Film Versus Suture For Wound Closure After Long Bone Fracture Fixation

    Directory of Open Access Journals (Sweden)

    IM Anuar Ramdhan

    2013-03-01

    Full Text Available INTRODUCTION: Coaptive film (i.e., Steri-StripsTM is an adhesive tape used to replace sutures in wound closure. The use of coaptive film for wound closure after long bone fracture fixation has not been well documented in the literature. METHODS: The aim of this prospective, randomized controlled trial comparing coaptive film with sutures for wound closure after long bone fracture fixation was skin closure time, incidence of wound complications and scar width at 12 week follow-up. Forty-five patients underwent femur fracture fixation (22 patients’ wound closed with sutures, 23 with coaptive film. RESULTS: The mean time for skin closure using coaptive film was 171.13 seconds compared to 437.27 seconds using suture. The mean wound lengths in the coaptive film group and suture group were 187.65 mm and 196.73 mm, respectively. One patient in each group had wound complications. CONCLUSION: Coaptive film is a time-saving procedure for skin closure following long bone fracture fixation. There is no difference in the incidence of wound complications and scar width between these two methods of skin closure.