WorldWideScience

Sample records for suspension metered dose

  1. Inhaled corticosteroid metered-dose inhalers: how do variations in technique for solutions versus suspensions affect drug distribution?

    Science.gov (United States)

    Robinson, Christie A; Tsourounis, Candy

    2013-03-01

    To assess the literature that evaluates how variations in metered-dose inhaler (MDI) technique affect lung distribution for inhaled corticosteroids (ICSs) formulated as MDI suspensions and solutions. PubMed (up to November 2012) and Cochrane Library (up to November 2012) were searched using the terms metered-dose inhalers, HFA 134a, Asthma/*drug therapy, and inhaled corticosteroids. In addition, reference citations from publications identified were reviewed. All articles in English from the data sources that assessed MDI technique comparing total lung distribution (TLD) of MDI solutions or suspensions formulated with ICSs were included in the review. Five relevant studies were identified. Five controlled studies compared how variations in MDI technique affect TLD for ICS MDI solutions with suspensions. MDI solutions resulted in greater TLD compared with larger particle MDI suspensions. Delayed or early inspiration upon device actuation of MDI solutions resulted in less TLD than coordinated actuation, but with a 3- to 4-times greater TLD than MDI suspensions inhaled using a standard technique. A sixth study evaluated inspiratory flow rates (IFR) for small, medium, and large particles. Rapid and slow IFRs resulted in similar TLD for small particles, while far fewer particles reached the airways with medium and large particles at rapid, rather than slow, IFRs. Based on the literature evaluated, standard MDI technique should be used for ICS suspensions. ICS MDI solutions can provide a higher average TLD than larger-particle ICS suspensions using standard technique, discoordinated inspiration and medication actuation timing, or rapid and slow IFRs. ICS MDI solutions allow for a more forgiving technique, which makes them uniquely suitable options for patients with asthma who have difficultly with MDI technique.

  2. Comparative study of budesonide as a nebulized suspension vs pressurized metered-dose inhaler in adult asthmatics

    DEFF Research Database (Denmark)

    Bisgaard, H; Nikander, K; Munch, E

    1998-01-01

    The study objective was to compare the effect of budesonide administered as a nebulized suspension as compared to a spray with a spacer in adult asthmatics. In a double-blind, double-dummy crossover study, 26 adult patients with moderately severe unstable asthma were randomized to three 4-week...... treatment periods with budesonide 0.8 mg b.i.d. administered by a pressurized metered-dose inhaler (pMDI) with spacer (Nebuhaler) and budesonide 1 mg and 4 mg b.i.d. administered by a Pari Inhalier Boy jet nebulizer. The nebulizer was activated only during inspiration. The total mass output was similar from...... the two devices but their fraction of small particles differed by a factor of 2 in favour of pMDI. Effect was evaluated from daily home measurements of peak expiratory flow (PEF), need of beta 2-agonist and symptom scores. Plasma cortisol and budesonide levels were measured in a subgroup of 10 patients...

  3. Radiation dose rate meter

    International Nuclear Information System (INIS)

    Kronenberg, S.; Siebentritt, C.R.

    1981-01-01

    A combined dose rate meter and charger unit therefor which does not require the use of batteries but on the other hand produces a charging potential by means of a piezoelectric cylinder which is struck by a manually triggered hammer mechanism. A tubular type electrometer is mounted in a portable housing which additionally includes a geiger-muller (Gm) counter tube and electronic circuitry coupled to the electrometer for providing multi-mode operation. In one mode of operation, an rc circuit of predetermined time constant is connected to a storage capacitor which serves as a timed power source for the gm tube, providing a measurement in terms of dose rate which is indicated by the electrometer. In another mode, the electrometer indicates individual counts

  4. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  5. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  6. Calibration of dose meters used in radiotherapy

    International Nuclear Information System (INIS)

    1979-01-01

    This manual is a practical guide, not a comprehensive textbook, to the instrumentation and procedures necessary to calibrate a radiation dose meter used in clinical practice against a secondary standard dose meter

  7. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  8. Properties of cellulose triacetate dose meter

    International Nuclear Information System (INIS)

    Tamura, N.; Tanaka, R.; Mitomo, S.; Matsuda, K.; Nagai, S.

    1981-01-01

    Several clear plastics and dyed plastics are commercially available for dosimetry in intense radiation field, especially for radiation processing applications. Among these dose meters cellulose triacetate (CTA) dose meter has two advantages for routine uses; (1) it has linear response in mega-rad dose region and (2) the main product form is long tape. However, the manufacture of Numelec CTA film so far used had been discontinued, and for this reason we developed a new film for dosimetry uses. To determine the manufacturing conditions of the film, we examined the influence of additives, triphenylphosphate (TPP) and others, and film thickness on the dosimetric properties, since these two conditions remarkably influence the sensitivity of the dose meter. It is necessary for the reliability of plastic dose meters that the radiation induced colorations should be understood as radiation chemical processes. In this paper we describe the determination of the manufacturing conditions of the new film, the feature of the new dose meter, and the coloration mechanism. (author)

  9. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  10. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  11. Understanding pressurized metered dose inhaler performance.

    Science.gov (United States)

    Ivey, James W; Vehring, Reinhard; Finlay, Warren H

    2015-06-01

    Deepening the current understanding of the factors governing the performance of the pressurized metered dose inhaler (pMDI) has the potential to benefit patients by providing improved drugs for current indications as well as by enabling new areas of therapy. Although a great deal of work has been conducted to this end, our knowledge of the physical mechanisms that drive pMDI performance remains incomplete. This review focuses on research into the influence of device and formulation variables on pMDI performance metrics. Literature in the areas of dose metering, atomization and aerosol evolution and deposition is covered, with an emphasis on studies of a more fundamental nature. Simple models which may be of use to those developing pMDI products are summarized. Although researchers have had good success utilizing an empirically developed knowledge base to predict pMDI performance, such knowledge may not be applicable when pursuing innovations in device or formulation technology. Developing a better understanding of the underlying mechanisms is a worthwhile investment for those working to enable the next generation of pMDI products.

  12. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  13. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    1990-08-21

    Aug 21, 1990 ... Two methods of administration of ipratropium bromide. (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (I) the conventional nebulisa- tion (15 children); and (iI) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant ...

  14. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    Two methods of administration of ipratropium bromide (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (i) the conventional nebulisation (15 children); and (ii) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant and similar fall in ...

  15. An alternative arrangement of metered dosing fluid using centrifugal pump

    Science.gov (United States)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  16. Nuclear Enterprises portable dose rate meter type PDR 2

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a portable battery powered dose rate meter covering the dose rate range from 0.05 to 500 mrad h -1 . It is designed to measure X- and γ-radiation dose rates over the energy range from 35 keV to 3 MeV. The radiation detector is an MX 164/S GM tube provided with a compensation sheath. The report describes the instrument under the headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  17. Absorbed dose rate meter for β-ray

    International Nuclear Information System (INIS)

    Bingo, K.

    1977-01-01

    The absorbed dose of β-ray depends on the energy of β-rays and the epidermal thickness of tissue in interest. In order to measure the absorbed dose rate at the interested tissue directly, the ratio of counting rate to absorbed dose should be constant independent of β-ray energy. In this purpose, a thin plastic scintillator was used as a detector with a single channel analyzer. The pulse height distribution, obtained using the scintillator whose thickness is less than the range of β-rays, shows a peak at a particular pulse height depending on the thickness of scintillator used. This means an increase of the number of pulses at lower pulse height. The lower level of discrimination and window width of the single channel analyzer are chosen according to the epidermal thickness of the tissue. In the experiment, scintillators of 0.5, 1, 2, 3, 5 and 10 mm thick were tested. It was found that desirable pulse height distribution, to obtain a constant dose sensitivity, could be obtained using the 2 mm thick scintillator. The sensitivity of the absorbed dose rate meter is constant within +-15% for β-ray with maximum energy from 0.4 to 3.5 MeV, when the absorbed dose rate for skin (epidermal thickness 7mg/cm 2 ) is measured. In order to measure the dose rate for a hand (epithermal thickness 40mg/cm 2 ) the lower level of discrimination is changed to be higher and at the same time the window width is also changed. Combining these techniques, one can get an absorbed dose rate meter for the tissue dose of various thickness, which has the constant dose sensitivity within +-15% for β-rays with maximum energy from 0.4 to 3.5 MeV

  18. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  19. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  20. Formulation and Development of Metered Dose Inhalations of Salbutamol in Solution Form

    Science.gov (United States)

    Khale, Anubha; Bajaj, Amrita

    2011-01-01

    In the present study attempts were made to prepare metered dose inhalation of salbutamol in solution form and compared it with the marketed metered dose inhalation in suspension form. Solution form of the drug was found better than marketed suspension formulation with respect to homogeneity and content uniformity. Propellant blend P-11 and P-12 in the proportion 30:70 was selected as it gave optimum vapour pressure. Surfactant oleic acid in concentration 10 mg per can was selected as it gave best results with clarity, spray pattern, vapour pressure, content per spray and rate of evaporation. Ethyl alcohol 2 ml per can was used as a cosolvent to give a clear solution, optimum vapour pressure, maximum content per spray and fair rate of evaporation. The selected formulation was subjected to the physico-chemical evaluation tests as per the standard pharmacopoeial procedures and the characteristics of the formulations were further compared with a conventional marketed formulation. In vitro study reveled the net respirable fraction was better than marketed preparation. PMID:22923867

  1. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    Directory of Open Access Journals (Sweden)

    Ashutosh Kale

    2010-01-01

    Full Text Available We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  2. Development of dose equivalent meters based on microdosimetric principles

    International Nuclear Information System (INIS)

    Booz, J.

    1984-01-01

    In this paper, the employment of microdosimetric dose-equivalent meters in radiation protection is described considering the advantages of introducing microdosimetric methods into radiation protection, the technical suitability of such instruments for measuring dose equivalent, and finally technical requirements, constraints and solutions together with some examples of instruments and experimental results. The advantage of microdosimetric methods in radiation protection is illustrated with the evaluation of dose-mean quality factors in radiation fields of unknown composition and with the methods of evaluating neutron- and gamma-dose fractions. - It is shown that there is good correlation between dose-mean lineal energy, anti ysub(anti D), and the ICRP quality factor. - Neutron- and gamma-dose fractions of unknown radiation fields can be evaluated with microdosimetric proportional counters without recurrence to other instruments and methods. The problems of separation are discussed. The technical suitability of microdosimetric instruments for measuring dose equivalent is discussed considering the energy response to neutrons and photons and the sensitivity in terms of dose-equivalent rate. Then, considering technical requirements, constraints, and solutions, the problem of the large dynamic range in LET, the large dynamic range in pulse rate, geometry of sensitive volume and electrodes, evaluation of dose-mean quality factors, calibration methods, and uncertainties are discussed. (orig.)

  3. Pharmaceutical Product Development: Intranasal Scopolamine (INSCOP) Metered Dose Spray

    Science.gov (United States)

    Putcha, Lakshmi; Crady, Camille; Putcha, Lakshmi

    2012-01-01

    Motion sickness (MS) has been a problem associated with space flight, the modern military and commercial air and water transportation for many years. Clinical studies have shown that scopolamine is the most effective medication for the prevention of motion sickness (Dornhoffer et al, 2004); however, the two most common methods of administration (transdermal and oral) have performance limitations that compromise its utility. Intranasal administration offers a noninvasive treatment modality, and has been shown to counter many of the problems associated with oral and transdermal administration. With the elimination of the first pass effect by the liver, intranasal delivery achieves higher and more reliable bioavailability than an equivalent oral dose. This allows for the potential of enhanced efficacy at a reduced dose, thus minimizing the occurrence of untoward side effects. An Intranasal scopolamine (INSCOP) gel formulation was prepared and tested in four ground-based clinical trials under an active Investigational New Drug (IND) application with the Food and Drug Administration (FDA). Although there were early indicators that the intranasal gel formulation was effective, there were aspects of formulation viscosity and the delivery system that were less desirable. The INSCOP gel formulation has since been reformulated into an aqueous spray dosage form packaged in a precise, metered dose delivery system; thereby enhancing dose uniformity, increased user satisfaction and palatability, and a potentially more rapid onset of action. Recent reports of new therapeutic indications for scopolamine has prompted a wide spread interest in new scopolamine dosage forms. The novel dosage form and delivery system of INSCOP spray shows promise as an effective treatment for motion sickness targeted at the armed forces, spaceflight, and commercial sea, air, and space travel markets, as well as prospective psychotherapy for mental and emotional disorders.

  4. Creation and clinical application of real-time dose monitor using dose area product meter

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Uoyama, Yoshinori; Iida, Hiroji; Mizushima, Takashi

    2004-01-01

    The management of patient dose has become more of an issue in recent years. Dose can be determined non-invasively and in real time through the use of a dose area product meter, but it is the area dose value that is obtained. Therefore, we created a program that estimates entrance skin dose (ESD) in real time from area dose values obtained during procedures. We used Microsoft Visual C++ 6.0 (Standard Edition) for the programming language and C language for the programming environment. The value was a maximum 285.4 mGy at ileus tube insertion when measuring ESD for radiography of the digestive organ and non-vascular type interventional radiology (IVR) using the created program and seeking the average according to the procedures. The program that we created can be considered valid for monitoring ESD correctly and in real time. (author)

  5. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  6. An energy-independent dose rate meter for beta and gamma radiation

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Keller, M.

    1986-01-01

    An easy to handle dose rate meter has been developed at the Juelich Nuclear Research Centre with a small probe for the energy-independent determination of the dose rate in mixed radiation fields. The dose rate meter contains a small ionisation chamber with a volume of 15.5 cm 3 . The window of the ionisation chamber consists of an aluminised plastic foil of 7 mg.cm -2 . The dose rate meter is suitable for determining the dose rate in skin. With a supplementary depth dose cap, the dose rate can be determined in tissue at a depth of 1 cm. The dose rate meter is energy-independent within +-20% for 147 Pm, 204 Tl and 90 Sr/ 90 Y beta radiation and for gamma radiation in the energy range above 35 keV. (author)

  7. The Design of a γ-dose rate monitoring meter Based on C8051F020

    International Nuclear Information System (INIS)

    Tan Wei; Liu Chong; Wu Longxiong; Yang Binhua

    2009-01-01

    This paper presents the design of γ-dose-rate monitoring meter based on C8051F020 single chip microcomputer (SCM), and also describes the solution of hardware and software. The peripheral circuit of USB is also included. This meter can rapidly measure γ-dose-rate and store more data in power failure. In addition, it is featured with low power, small size, strong anti-interference and accurate measurement. (authors)

  8. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    OpenAIRE

    Mingrong Zhang; Songhao Wang; Yu-Ching Yang

    2016-01-01

    The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-de...

  9. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  10. Problems Associated with the Use of the Radiochromic Dye Film as a Radiation Dose Meter

    DEFF Research Database (Denmark)

    Hansen, Johnny; Wille, Mads; Olsen, Kjeld J.

    1984-01-01

    of coloration. The dose response has been found to depend strongly on: the time span between irradiation and measurement; the irradiation temperature; and the dose rate at doses above 50 kGy for low-LET radiation. Irradiation in vacuum (right-pointing angle bracket1 Pa) and in air produced the same dose......A thorough investigation has been made of the problems involved in using a dye film dose meter for precision dosimetry at high doses, using both low- and high-LET radiation. The study includes: time course of coloration following irradiation at various dose levels; dose response after irradiation...

  11. Calibration and quality control for personnel dose meter

    International Nuclear Information System (INIS)

    Wu Rongtao; Zhang Dianqin

    1999-01-01

    Calibration and quality control are the important aspects to assure thermoluminescence dose measurement compliance with the technical standards. The author discussed some problems to implement technical standards and regulations

  12. Study on method of dose estimation for the Dual-moderated neutron survey meter

    International Nuclear Information System (INIS)

    Zhou, Bo; Li, Taosheng; Xu, Yuhai; Gong, Cunkui; Yan, Qiang; Li, Lei

    2013-01-01

    In order to study neutron dose measurement in high energy radiation field, a Dual-moderated survey meter in the range from 1 keV to 300 MeV mean energies spectra has been developed. Measurement results of some survey meters depend on the neutron spectra characteristics in different neutron radiation fields, so the characteristics of the responses to various neutron spectra should be studied in order to get more reasonable dose. In this paper the responses of the survey meter were calculated under different neutron spectra data from IAEA of Technical Reports Series No. 318 and other references. Finally one dose estimation method was determined. The range of the reading per H*(10) for the method estimated is about 0.7–1.6 for the neutron mean energy range from 50 keV to 300 MeV. -- Highlights: • We studied a novel high energy neutron survey meter. • Response characteristics of the survey meter were calculated by using a series of neutron spectra. • One significant advantage of the survey meter is that it can provide mean energy of radiation field. • Dose estimate deviation can be corrected. • The range of corrected reading per H*(10) is about 0.7–1.6 for the neutron fluence mean energy range from 0.05 MeV to 300 MeV

  13. The development of BH3105E type neutron dose-equivalent meter

    International Nuclear Information System (INIS)

    Ji Changsong; Wang Tingting; Zhang Shuheng; Tan Baozeng

    2011-01-01

    A new BH3105E Type Neutron Dose-equivalent Meter has been developed. The 'multi-stick' ab- sorption method is used for thermal -14 MeV neutron equal dose-equivalent detection, what gives a high neutron sensitivity of 5 cps/μSv · h-1. RS-232 interface is accepted for signal communication (authors)

  14. A wide range survey meter for estimating γ- and β-dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-09-01

    A survey meter has been developed to measure β-dose rates in the range 0.1 - 100 rad/h (1 mGy/h - 1 Gy/h) and γ-dose rates in the range 1 mrad/h - 100 rad/h (10 μGy/h-1 Gy/h). It also provides an audible warning of high γ-dose rates and an audible and visible warning when a predetermined γ-dose is exceeded. The report describes the design of the survey meter and presents data measured on the performance of an engineering prototype. Factors which affect performance and have been investigated are temperature, battery voltage (and type of battery), GM counter counting loss, direction of incident radiation, and energy of γ-rays. Finally, the application and calibration of the survey meter are discussed. (auth)

  15. Bone-and-muscle-equivalent solid chemical dose meters for photon and electron doses above one kilorad

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Rosenstein, M.; Levine, H.

    1975-01-01

    Conventional solid dose meters, such as plastic films, powders, emulsions, glasses, ceramics and gels, have a response to ionizing photons and electrons that varies markedly over a broad spectrum when compared with the absorption characteristics of biological tissues. New radiochromic dyed plastic dose meters have been developed with X- and gamma ray and electron energy absorption cross-sections (calculated) and radiation energy responses (experimental) corresponding approximately to those for human muscle and bone, for a spectrum from a few keV to at least 10 MeV. Three-dimensional solid dose meters useful over the absorbed dose range of 10 3 to 10 6 rad are formed by thermosetting a selected combination of monomers containing the radiochromic dye in solution. Thin-film dose meters for the dose range 10 5 to 10 7 rad are formed by casting on optically flat surfaces strippable layers of special combinations of polymers and dyes in solution. The response of these systems to X- and gamma rays and electrons has been studied over various radiation spectra, dose-rates and temperatures during irradiation. (author)

  16. Comparative investigation of three dose rate meters for their viability in pulsed radiation fields

    International Nuclear Information System (INIS)

    Gotz, M; Karsch, L; Pawelke, J

    2015-01-01

    Pulsed radiation fields, characterized by microsecond pulse duration and correspondingly high pulse dose rates, are increasingly used in therapeutic, diagnostic and research applications. Yet, dose rate meters which are used to monitor radiation protection areas or to inspect radiation shielding are mostly designed, characterized and tested for continuous fields and show severe deficiencies in highly pulsed fields. Despite general awareness of the problem, knowledge of the specific limitations of individual instruments is very limited, complicating reliable measurements. We present here the results of testing three commercial dose rate meters, the RamION ionization chamber, the LB 1236-H proportional counter and the 6150AD-b scintillation counter, for their response in pulsed radiation fields of varied pulse dose and duration. Of these three the RamION proved reliable, operating in a pulsed radiation field within its specifications, while the other two instruments were only able to measure very limited pulse doses and pulse dose rates reliably. (paper)

  17. Passive Rn dose meters - measuring methods appropriate for large measurement series

    International Nuclear Information System (INIS)

    Urban, M.; Kiefer, H.

    1985-01-01

    Passive integrating measuring methods can be classified in several groups by their functioning principle, e.g. spray chambers or open chambers with nuclear trace detectors or TL detectors, open detectors, activated carbon dose meters with or without TL detectors. According to the functioning principle, only radon or radon and fission products can be detected. The lecture gives a survey of the present state of development of passive Rn dose meters. By the example of the Ra dose meter developed at Karlsruhe which was used in inquiry measurements carried out in Germany, Switzerland, the Netherlands, Belgium and Austria, etching technology, estimation of measuring uncertainties, reproducibility and fading behaviour shall be discussed. (orig./HP) [de

  18. Evaluation of energy responses for neutron dose-equivalent meters made in Japan

    International Nuclear Information System (INIS)

    Saegusa, J.; Yoshizawa, M.; Tanimura, Y.; Yoshida, M.; Yamano, T.; Nakaoka, H.

    2004-01-01

    Energy responses of three types of Japanese neutron dose-equivalent (DE) meters were evaluated by Monte Carlo simulations and measurements. The energy responses were evaluated for thermal neutrons, monoenergetic neutrons with energies up to 15.2 MeV, and also for neutrons from such radionuclide sources as 252 Cf and 241 Am-Be. The calculated results were corroborated with the measured ones. The angular dependence of the response and the DE response were also evaluated. As a result, reliable energy responses were obtained by careful simulations of the proportional counter, moderator and absorber of the DE meters. Furthermore, the relationship between pressure of counting gas and response of the DE meter was discussed. By using the obtained responses, relations between predicted readings of the DE meters and true DE values were studied for various workplace spectra

  19. Comparative in vitro evaluation of four corticosteroid metered dose inhalers : Consistency of delivered dose and particle size distribution

    NARCIS (Netherlands)

    de Vries, Tjalling W; Rottier, Bart L; Gjaltema, Doetie; Hagedoorn, Paul; Frijlink, Henderik W; de Boer, Anne H

    2009-01-01

    Introduction: Recent developments concerning pressurized metered dose inhalers (pMDIs) with inhaled corticosteroids (ICS) are the introduction of ciclesonide and the replacement of propellants. As the results of in vivo studies depend on pMDI performance, it is necessary to evaluate pMDIs in vitro

  20. High-voltage power supply of ND6 portable dose rate meter

    International Nuclear Information System (INIS)

    Wang Shaling

    2001-01-01

    Portable dose rate meter needs to be equipped with a set of high-voltage power supply which is supplied by batteries and has characteristic of high quality, low energy expense and small size. The author introduces application conditions and performance guide line

  1. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  2. Performance evaluation of domestic prototype dose area product meter SFT-1

    International Nuclear Information System (INIS)

    Lee, Ho Sun; Han, Seong Gyu; Roh, Young Roh; Lim, Hyun Jong; Kim, Jung Min; Kim, Jong Uk; Chae, Hyun Sik; Yoon, Yong Su

    2016-01-01

    The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R and BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product. Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatabilit y coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria

  3. Instrument evaluation no. 9. Mini-instruments dose rate meter type 5 - 1OR

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered dose rate meter covering the dose rate range from 0 to 200 mrad h -1 . The instrument is designed to measure X- and γ-radiation dose rates over the energy range from 45 keV to 3 MeV. The radiation detector of the instrument is a GM tube with a specially designed energy compensation sheath. This detector is incorporated in a probe connected to the rate meter by an extensible cable which may be either hand-held or clipped on to the top of the instrument case. All the measurements in this report have been taken with the long axis of the probe normal to the direction of the incident radiation, the orientation recommended by the manufacturer. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; effect of ambient temperature; mechanical characteristics; summary of performance; conclusions. (U.K.)

  4. Fundamental studies on miniature dose meter using variable capacitance Si-diode

    International Nuclear Information System (INIS)

    Inoue, Yoshio

    1976-01-01

    The results of fundamental studies on development of a miniature dose meter using a semiconductor applicable for dosimetry in both intracavitary and external radiotherapy are described. Many different instruments have been applied in clinical dosimetry for regional lesions, mostly in phantom studies, e. g. the small sized ionization chamber, the fluoroluminescence glass dose meter and the thermoluminescence dose meter. However, there are considerable problems regarding safety, reproducibility, and simplicity for regional dosimetry of intracavitary lesions, such as genitourinary, gastrointestinal and respiratory malignancies. To overcome these problems, an attempt was made to develop a miniature catheter type detector using a variable capacitance Si-diode for gamma ray dosimetry. The newly developed miniature dose meter using a semiconductor has the following characteristics. As the tip of detector (23mm long and 3mm in diameter) is very small, the apparatus unit is easy to manipulate in the dosimetry of intracavitary lesions. As no voltage is supplied to the detector, there is no danger of electric shock from in vivo studies. A strict linearity existed between the radiation dose rate and the generated voltage even when the range of experimental irradiation dose rate was extremely wide. The sensitivity of the detector was affected by the environmental temperature, but it was easy to correct the sensitivity by applying a special calibration chart to the value derived from a thermister enclosed in the detector. Even with the experimental irradiation of more than 50,000R, no changes in the sensitivity of the detector were observed. Thus, the durability of the apparatus was shown to be excellent. (auth.)

  5. Instrument evaluation no. 8. Nuclear Enterprises beta/gamma dose rate meter type 0500

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered survey meter covering the dose rate range from 0 to 10,000 mrad h -1 and the dose range 0 to 1000 mrad. The instrument was designed to measure X and γ-radiation dose and dose rate over a wide energy range, and also β-radiation dose and dose rate. An unsealed ionisation chamber is used as the detector. The aluminised melinex thin end window of the chamber is provided with a detachable plastic end cap. The calibration plane of the chamber is indicated by a cross on the side of the instrument. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; conclusions. (U.K.)

  6. A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    A patient dose survey was carried out for femoral arteriogram procedures at the Sir Charles Gairdner Hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. A dose-area product meter was used to determine the dose-area product delivered to patients. Radiographic and patient details were logged with dose-area product for each part of each procedure. Mean energy imparted, mean effective dose and effective dose equivalent are calculated for the examinations. Calculated effective doses are shown to produce results consistent with those of other authors. We present a method for dealing with a complex radiographic procedure including multiple radiographs and fluoroscopy in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. The effective dose varies considerably from examination to examination due to the large range in the number of radiographs taken in any one procedure. A useful index can be obtained by logging the number of radiographs in each region, and fluoroscopy time, from which the effective dose may be easily calculated. These measurements extend a continuing survey of doses for common diagnostic radiographic examinations which previously included the simple examinations: lumbar spine, abdoment and pelvis. (author)

  7. Evaluation of patient radiation doses using DAP meter in interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Sam [Dept. of Radiological Technology. Shingu University, Sungnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu Univeristy, Kyushu (Japan)

    2017-03-15

    The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipment in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effective of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were 237.7 Gy·cm{sup 2} in TACE, 17.3 Gy·cm{sup 2} in AVF, 114.1 Gy·cm{sup 2} in LE PTA and STENT, 188.5 Gy·cm{sup 2} in TFCA, 383.5 Gy·cm{sup 2} in Aneurysm Coil, 64.6 Gy·cm{sup 2} in PTBD, 64.6 Gy·cm{sup 2} in Biliary Stent, 22.4 Gy·cm{sup 2} in PCN, 4.3 Gy·cm{sup 2} in Hickman, 2.8 Gy·cm{sup 2} in Chemo-port, 4.4 Gy·cm{sup 2} in Perm-Cather, 17.1 Gy·cm{sup 2} in PCD, and 357.9 Gy·cm{sup 2} in Vis, EMB. Dose reference level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipment and procedures in the interventional radiology procedures, further studies and monitoring are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

  8. Conceptual basis for the radiometric dye film dose meter as a test of particle track theory

    International Nuclear Information System (INIS)

    Hansen, J.W.

    1980-05-01

    This report is a summary of a lecture held at the Danish-Polish Symposium on Radiation Chemistry in Warsaw, October 1979, describing an initiated work connected to the particle track theory worked out by R. Katz and coworkers. A short description is given of the theory and the applicability of the theory in the use of the radiometric dye cyanide film dose meter as a detector in radiation of different qualities. A few experimental results are given. (author)

  9. A study of the responses of neutron dose equivalent survey meters with computer codes

    International Nuclear Information System (INIS)

    Sartori, D.E.; Beer, G.P. de

    1983-01-01

    The ANISN and DOT discrete-ordinates radiation transport codes for one and two dimensions have been proved as effective and simple techniques to study the response of dose equivalent neutron detectors. Comparisons between results of an experimental calibration of the Harwell 95/0075 survey meter and calculated results rendered satisfactory agreement, considering the different techniques and sources of error involved. Possible improvements in the methods and designs and causes of error are discussed. (author)

  10. Low dose creatine supplementation enhances sprint phase of 400 meters swimming performance.

    Science.gov (United States)

    Anomasiri, Wilai; Sanguanrungsirikul, Sompol; Saichandee, Pisut

    2004-09-01

    This study demonstrated the effect of low dose creatine supplement (10 g. per day) on the sprinting time in the last 50 meters of 400 meters swimming competition, as well as the effect on exertion. Nineteen swimmers in the experimental group received creatine monohydrate 5 g with orange solution 15 g, twice per day for 7 days and nineteen swimmers in the control group received the same quantity of orange solution. The results showed that the swimmers who received creatine supplement lessened the sprinting time in the last 50 meters of 400 meters swimming competition than the control group. (p<0.05). The results of Wingate test (anaerobic power, anaerobic capacity and fatigue index) compared between pre and post supplementation. There was significant difference at p<0.05 in the control group from training effect whereas there was significant difference at p<0.000 from training effect and creatine supplement in the experiment group. Therefore, the creatine supplement in amateur swimmers in the present study enhanced the physical performance up to the maximum capacity.

  11. In vitro performance of three combinations of spacers and pressurized metered dose inhalers for treatment in children

    DEFF Research Database (Denmark)

    Berg, E; Madsen, J; Bisgaard, H

    1998-01-01

    The performance of pressurized metered dose inhalers (pMDIs) and spacers in correct dose recommendations is important, but limited information on dose delivery and fine-particle dose from different combinations of spacers and pMDIs is available. In this study, three combinations of spacers and p...... and spacers, with the NebuChamber giving the highest dose, both as delivered dose and in droplets account for these differences....

  12. The radiochromic dye film dose meter as a possible test of particle track theory

    International Nuclear Information System (INIS)

    Hansen, J.W.; Jensen, M.; Katz, R.

    1980-09-01

    The response characteristic of the thin-film radiometric dye cyanide plastic dose meter to ionizing radiation of electrons and heavy charged particles is investigated as a possible test of the particle track theory worked out by Robert Katz and coworkers. Dose response curves for low-LET radiation have been investigated and are used for a quality estimation of the response for protons and oxygen ions at 16 and 4 MeV/amu, respectively. A bleaching effect on the colouration at high doses intimates that the target cannot be interpreted lieerally, but it might still be possinle to transfer the function of the macroscopic dose response to a theoretical dose response curve in a microscopic scale for a single ion. From this relation the macroscopic dose response curve can be determined qhen the film is irradiated with heavy ions. It will be shown theoretically that for protons there is no saturation in the track core, whereas calculations for oxygen ions show a heavy saturation in the track core, which means that a part of the ions loose their energy ineffectively. We can conclude that itis possible qualitatively to predict the dose response curve for high-LET particles by means of the dose response curve for low-LET radiation. (author)

  13. Measuring set: Reactor Power Meter (type of SG-8), Reactor Energy Meter (type of SG-11) and Digital Dose Meter (type of SG-9) for reactor rigs operation. Zestaw pomiarowy: miernik mocy reaktora (typ SG-8), miernik energii reaktora (typ SG-11) oraz cyfrowy miernik dawki (typ SG-9) dla potrzeb eksploatacji sond reaktorowych

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1982-01-01

    A measuring set consisting of the Reactor Power Meter, Reactor Energy Meter and Digital Dose Meter is described. The gamma radiation of water in the reactor primary cooling circuit reaches the ionisation chamber and involves the output current, driving the Reactor Power Meter and Reactor Energy Meter. The Digital Dose Meter is controlled by the output current of the self-powered detector mounted inside the reactor rig.

  14. Two survey meters for measuring low γ-ray dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1979-01-01

    Two low-level survey meters have been developed which have numerical displays. The first is of the light-emitting diode (LED) type. The second is a liquid crystal display (LCD). The design of both instruments is described and results of measurements of performance are presented. They measure γ dose rates from background up to 2 mrad/h (20 μGy/h) for γ-rays in the energy range 0.05-1.25 MeV. They can be used at temperatures between -20 deg C and +50 deg C. Statistical accuracy and battery life both depend upon a number of factors and this dependence is shown. A later section describes the intended application of the survey meters. An appendix describes the circuit adjustments which are necessary and when they must be made. (author)

  15. Formulation design of oral pediatric Acetazolamide suspension: dose uniformity and physico-chemical stability study.

    Science.gov (United States)

    Santoveña, Ana; Suárez-González, Javier; Martín-Rodríguez, Cristina; Fariña, José B

    2017-03-01

    The formulation of an active pharmaceutical ingredient (API) as oral solution or suspension in pediatrics is a habitual practice, due to the non-existence of many commercialized medicines in pediatric doses. It is also the simplest way to prepare and administer them to this vulnerable population. The design of a formulation that assures the dose and the system stability depends on the physico-chemical properties of the API. In this study, we formulate a class IV API, Acetazolamide (AZM) as suspension for oral administration to pediatric population. The suspension must comply attributes of quality, safety and efficacy for this route of administration. We use simple compounding procedures, as well as fewer pure excipients, as recommended for children. Mass and uniformity content assays and physical and chemical stability studies were performed. To quantify the API an UPLC method was used. We verified the physico-chemical stability of the suspensions and that they passed the mass test of the European Pharmacopeia (EP), but not the dose uniformity test. This reveals that AZM must be formulated as liquid forms with a more complex system of excipients (not usually indicated in pediatrics), or otherwise solid forms capable of assuring uniformity of mass and dose for every dosage unit.

  16. Preparation and the Biopharmaceutical Evaluation for the Metered Dose Transdermal Spray of Dexketoprofen

    Science.gov (United States)

    Luo, Huafei; Zhu, Zhuangzhi; Wu, Yubo; Luo, Jing; Wang, Hao

    2014-01-01

    The objective of the present work was to develop a metered dose transdermal spray (MDTS) formulation for transdermal delivery of dexketoprofen (DE). DE release from a series of formulations was assessed in vitro. Various qualitative and quantitative parameters like spray pattern, pump seal efficiency test, average weight per metered dose, and dose uniformity were evaluated. The optimized formulation with good skin permeation and an appropriate drug concentration and permeation enhancer (PE) content was developed incorporating 7% (w/w, %) DE, 7% (v/v, %) isopropyl myristate (IPM), and 93% (v/v, %) ethanol. In vivo pharmacokinetic study indicated that the optimized formulation showed a more sustainable plasma-concentration profile compared with the Fenli group. The antiinflammatory effect of DE MDTS was evaluated by experiments involving egg-albumin-induced paw edema in rats and xylene-induced ear swelling in mice. Acetic acid-induced abdominal constriction was used to evaluate the anti-nociceptive actions of DE MDTS. Pharmacodynamic studies indicated that the DE MDTS has good anti-inflammatory and anti-nociceptive activities. Besides, skin irritation studies were performed using rat as an animal model. The results obtained show that the MDTS can be a promising and innovative therapeutic system used in transdermal drug delivery for DE. PMID:24660066

  17. Preparation and the Biopharmaceutical Evaluation for the Metered Dose Transdermal Spray of Dexketoprofen

    Directory of Open Access Journals (Sweden)

    Wangding Lu

    2014-01-01

    Full Text Available The objective of the present work was to develop a metered dose transdermal spray (MDTS formulation for transdermal delivery of dexketoprofen (DE. DE release from a series of formulations was assessed in vitro. Various qualitative and quantitative parameters like spray pattern, pump seal efficiency test, average weight per metered dose, and dose uniformity were evaluated. The optimized formulation with good skin permeation and an appropriate drug concentration and permeation enhancer (PE content was developed incorporating 7% (w/w, % DE, 7% (v/v, % isopropyl myristate (IPM, and 93% (v/v, % ethanol. In vivo pharmacokinetic study indicated that the optimized formulation showed a more sustainable plasma-concentration profile compared with the Fenli group. The antiinflammatory effect of DE MDTS was evaluated by experiments involving egg-albumin-induced paw edema in rats and xylene-induced ear swelling in mice. Acetic acid-induced abdominal constriction was used to evaluate the anti-nociceptive actions of DE MDTS. Pharmacodynamic studies indicated that the DE MDTS has good anti-inflammatory and anti-nociceptive activities. Besides, skin irritation studies were performed using rat as an animal model. The results obtained show that the MDTS can be a promising and innovative therapeutic system used in transdermal drug delivery for DE.

  18. An In Vitro Aerosolization Efficiency Comparison of Generic and Branded Salbutamol Metered Dose Inhalers

    Directory of Open Access Journals (Sweden)

    Sara Rahimkhani, Saeed Ghanbarzadeh, Ali Nokhodchi, Hamed Hamishehkar

    2017-03-01

    Full Text Available Background: Due to the high rate of pulmonary diseases, respiratory drug delivery systems have been attracted excessive attention for the past decades. Because of limitations and growing drug bill, physicians are encouraged to prescribe generically whenever possible. The purpose of this study was to evaluate whether there was any significant difference in aerosolization performance between a reference brand Salbutamol (A Metered Dose Inhalers (MDIs and two generic products (B and C. Methods: The aerosolization performance of MDIs was evaluated by calculating aerosolization indexes including fine particle fraction (FPF, fine particle dose (FPD, geometric standard deviation (GSD and mass median aerodynamic diameters (MMAD by using the next generation impactor. Results: Although aerosolization indexes of MDI A were superior than the Iranian brands, but the differences were not statistically significant. Conclusion: These results verified that generic MDIs deliver similar quantities of Salbutamol to the reference brand and aerosolization performance parameters of generic Salbutamol MDIs did not differ significantly from the reference brand.

  19. Double ionization chamber survey meter for the separate measurement of penetrating and non-penetrating dose

    International Nuclear Information System (INIS)

    Lucas, A.C.

    1987-01-01

    The full capabilities of an advanced 8-bit microprocessor have been utilized in construction of a wide range, multiplexing survey meter based on dual electrometers and ionization chambers. The ionization chambers are constructed of modular conducting and non-conducting parts in such a way that the angular dependence for measurement of beta radiation is controlled by design. Display functions for the high range instrument include logarithmic or linear analog display, digital display of rate or dose, SI or English units, optionally for either total, penetrating, or non-penetrating dose. The instrument is presently configured to operate in the range 0.1 R/hr to 50,000 R/hr in support of the requirements of Regulatory Guide 19.7

  20. Solution or suspension - Does it matter for lipid based systems? In vivo studies of chase dosing lipid vehicles with aqueous suspensions of a poorly soluble drug.

    Science.gov (United States)

    Larsen, A T; Holm, R; Müllertz, A

    2017-08-01

    In this study, the potential of co-administering an aqueous suspension with a placebo lipid vehicle, i.e. chase dosing, was investigated in rats relative to the aqueous suspension alone or a solution of the drug in the lipid vehicle. The lipid investigated in the present study was Labrafil M2125CS and three evaluated poorly soluble model compounds, danazol, cinnarizine and halofantrine. For cinnarizine and danazol the oral bioavailability in rats after chase dosing or dosing the compound dissolved in Labrafil M21515CS was similar and significantly higher than for the aqueous suspension. For halofantrine the chase dosed group had a tendency towards a low bioavailability relative to the Labrafil M2125CS solution, but still a significant higher bioavailability relative to the aqueous suspension. This could be due to factors such as a slower dissolution rate in the intestinal phase of halofantrine or a lower solubility in the colloidal structures formed during digestion, but other mechanisms may also be involved. The study thereby supported the potential of chase dosing as a potential dosing regimen in situations where it is beneficial to have a drug in the solid state, e.g. due to chemical stability issues in the lipid vehicle. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Economics of "essential use exemptions" for metered-dose inhalers under the Montreal Protocol.

    Science.gov (United States)

    DeCanio, Stephen J; Norman, Catherine S

    2007-10-01

    The Montreal Protocol on Substances that Deplete the Ozone Layer has led to rapid reductions in the use of ozone-depleting substances worldwide. However, the Protocol provides for "essential use exemptions" (EUEs) if there are no "technically and economically feasible" alternatives. An application that might qualify as an "essential use" is CFC-powered medical metered-dose inhalers (MDIs) for the treatment of asthma and chronic obstructive pulmonary disease (COPD), and the US and other nations have applied for exemptions in this case. One concern is that exemptions are necessary to ensure access to medications for low-income uninsureds. We examine the consequences of granting or withholding such exemptions, and conclude that government policies and private-sector programs are available that make it economically feasible to phase out chlorofluorocarbons (CFCs) in this application, thereby furthering the global public health objectives of the Montreal Protocol without compromising the treatment of patients who currently receive medication by means of MDIs.

  2. Humidity affects the morphology of particles emitted from beclomethasone dipropionate pressurized metered dose inhalers.

    Science.gov (United States)

    Ivey, James W; Bhambri, Pallavi; Church, Tanya K; Lewis, David A; McDermott, Mark T; Elbayomy, Shereen; Finlay, Warren H; Vehring, Reinhard

    2017-03-30

    The effects of propellant type, cosolvent content, and air humidity on the morphology and solid phase of the particles produced from solution pressurized metered dose inhalers containing the corticosteroid beclomethasone dipropionate were investigated. The active ingredient was dissolved in the HFA propellants 134a and 227ea with varying levels of the cosolvent ethanol and filled into pressurized metered dose inhalers. Inhalers were actuated into an evaporation chamber under controlled temperature and humidity conditions and sampled using a single nozzle, single stage inertial impactor. Particle morphology was assessed qualitatively using field emission scanning electron microscopy and focused ion beam-helium ion microscopy. Drug solid phase was assessed using Raman microscopy. The relative humidity of the air during inhaler actuation was found to have a strong effect on the particle morphology, with solid spheroidal particles produced in dry air and highly porous particles produced at higher humidity levels. Air humidification was found to have no effect on the solid phase of the drug particles, which was predominantly amorphous for all tested formulations. A critical level of air relative humidity was required to generate porous particles for each tested formulation. This critical relative humidity was found to depend on the amount of ethanol used in the inhaler, but not on the type of propellant utilized. The results indicate that under the right circumstances water vapor saturation followed by nucleated water condensation or ice deposition occurs during particle formation from evaporating propellant-cosolvent-BDP droplets. This finding reveals the importance of condensed water or ice as a templating agent for porosity when particle formation occurs at saturated conditions, with possible implications on the pharmacokinetics of solution pMDIs and potential applications in particle engineering for drug delivery. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Mobile-Dose: A Dose-Meter Designed for Use in Automatic Machineries for Dose Manipulation in Nuclear Medicine

    Science.gov (United States)

    de Asmundis, Riccardo; Boiano, Alfonso; Ramaglia, Antonio

    2008-06-01

    Mobile-Dose has been designed for a very innovative use: the integration in a robotic machinery for automatic preparation of radioactive doses, to be injected to patients in Nuclear Medicine Departments, with real time measurement of the activity under preparation. Mobile-Dose gives a constant measurement of the dose during the filling of vials or syringes, triggering the end of the filling process based on a predefined dose limit. Several applications of Mobile-Dose have been delivered worldwide, from Italian hospitals and clinics to European and Japanese ones. The design of such an instrument and its integration in robotic machineries, was required by an Italian company specialised in radiation protection tools for nuclear applications, in the period 2001-2003. At the time of its design, apparently no commercial instruments with a suitable interfacing capability to the external world existed: we designed it in order to satisfy all the strict requirements coming from the medical aspects (precision within 10%, repeatability, stability, time response) and from the industrial conceiving principles that are mandatory to ensure a good reliability in such a complicated environment. The instrument is suitable to be used in standalone mode too, thanks to its portability and compactness and to the intelligent operator panel programmed for this purpose.

  4. Development of a hotspot detector with an acrylic filter and dose rate survey meters

    International Nuclear Information System (INIS)

    Shirakawa, Yoshiyuki; Yamano, Toshiya; Kobayashi, Yusuke; Hara, Masaki

    2013-01-01

    Fukushima and adjacent regions still have a large number of high dose rate areas called hotspots. It is necessary to know these hotspots for efficient decontamination of radioactive substances such as 137 Cs and for relief of residents coming home. To find the hotspots rapidly, we have to specify the direction of the area where the dose rate is at least 1μSv/h higher than those of surroundings. We have developed a detector that consists of an acrylic filter and three NaI(Tl) scintillation survey meters, and the detector can be expected to indicate the direction of the hotspot in the short time. A basic performance of the detector was examined by using acrylic filters of 10, 15, 20 and 25cm diameter and a tiny sealed 137 Cs source of 3 MBq as the alternative of a hotspot. It demonstrated the possibility of identifying the direction of γ-rays emitted from the source in 90 seconds. (author)

  5. Impact of droplet evaporation rate on resulting in vitro performance parameters of pressurized metered dose inhalers.

    Science.gov (United States)

    Sheth, Poonam; Grimes, Matthew R; Stein, Stephen W; Myrdal, Paul B

    2017-08-07

    Pressurized metered dose inhalers (pMDIs) are widely used for the treatment of pulmonary diseases. The overall efficiency of pMDI drug delivery may be defined by in vitro parameters such as the amount of drug that deposits on the model throat and the proportion of the emitted dose that has particles that are sufficiently small to deposit in the lung (i.e., fine particle fraction, FPF). The study presented examines product performance of ten solution pMDI formulations containing a variety of cosolvents with diverse chemical characteristics by cascade impaction with three inlets (USP induction port, Alberta Idealized Throat, and a large volume chamber). Through the data generated in support of this study, it was demonstrated that throat deposition, cascade impactor deposition, FPF, and mass median aerodynamic diameter of solution pMDIs depend on the concentration and vapor pressure of the cosolvent, and the selection of model throat. Theoretical droplet lifetimes were calculated for each formulation using a discrete two-stage evaporation process model and it was determined that the droplet lifetime is highly correlated to throat deposition and FPF indicating that evaporation kinetics significantly influences pMDI drug delivery. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. EVALUATION OF THE METERED-DOSE INHALER TECHNIQUE AMONG HEALTHCARE PROVIDERS

    Directory of Open Access Journals (Sweden)

    E. Nadi F. Zeraati

    2005-07-01

    Full Text Available Poor inhaler technique is a common problem both in asthmatic patients and healthcare providers, which contributes to poor asthma control. This study was performed to evaluate the adequacy of metered-dose inhaler (MDI technique in a sample of physicians and nurses practicing in hospitals of Hamadan University of Medical Sciences. A total of 173 healthcare providers voluntary participated in this study. After the participants answered a questionnaire aimed at identifying their involvement in MDI prescribing and counseling, a trained observer assessed their MDI technique using a checklist of nine steps. Of the 173 participants, 35 (20.2% were physicians and 138 (79.8% were nurses. Only 12 participants (6.93% performed all steps correctly. Physicians performed essential steps significantly better than nurses (85.7% vs. 63.8%, P < 0.05. The majority of healthcare providers responsible for instructing patients on the correct MDI technique were unable to perform this technique correctly, indicating the need for regular formal training programs on inhaler techniques.

  7. Generalization of cavity theory for the case of neutrons. Application to the calculation of the sensitivity of a dose meter

    International Nuclear Information System (INIS)

    Simoen, J.P.

    1981-01-01

    When a heterogeneous dose meter is used - i.e. a dose meter in which the wall and the detector medium are not of identical composition - it is possible to establish a general link between the information collected and the absorbed dose sought only on the basis of a measurement theory. For electrons, a cavity theory was progressively developed (Bragg, Gray, Burlin) and at present represents a model making possible the interpretation of measurements of doses due to photons. Regarding neutrons, only a number of special cases have been handled; as far as we are aware, no general theory similar to that of Burlin has been put forward. It is, however, possible, to generalize the cavity theory by using Burlin's analysis as a starting point and taking into account the variety of secondary charged particles brought into motion by the neutrons, particularly when the dimensions of the cavity are of the same order as, or are large in respect to, the range of the secondary charged particles. The present paper therefore proposes an analytical expression for the absorbed dose sought as a function of the data collected. This relationship involves two components, one relating to directly ionizing particles generated in the dose meter wall and the other to particles generated in the detector medium; it also takes account of the variation in the radiometrological ''constant'' associated with the detector medium as a function of the type and energy of the secondary particles. Burlin's theory then constitutes a special case of this general theory. The general relationship established makes it possible to express the response of a dose meter in terms of the various parameters relating to the characteristics of the instrument and to the primary and secondary particles concerned. (author)

  8. Calculation of radiation dose to infants from radioactive breast milk and suspensions necessary to constrain dose

    International Nuclear Information System (INIS)

    Cormack, J.; Shearer, J.

    2000-01-01

    Full text: For nuclear medicine patients who are breast feeding an infant, special radiation safety precautions may need to be taken. An estimate of the potential radiation dose to the child from ingested milk must be made, and breast-feeding may need to be suspended until levels of radioactivity in the breast-milk have fallen to acceptable levels. The risk of radiation to the child must be weighed against the benefits of breast-feeding and the possible trauma to both mother and child arising from interruption or cessation of the milk supply. In the United States, the Nuclear Regulatory Commission (NRC) has already published regulations which will necessitate an estimate of the infant's dose from breast milk to be made, in principle, for every breast-feeding patient. There is obviously, therefore, a need to provide a rapid and reliable means of estimating such doses. A spreadsheet template which automatically calculates the cumulative dose to breast feeding infants based on any multi-exponential clearance of activity from the breast milk, and any pattern of feeding, has been developed by the authors. The time (post administration) for which breast-feeding should be interrupted in order to constrain the radiation dose to a selected limit is also calculated along with the concentration of activity in breast milk at which feeding can resume. The effect of changing dose limits, feeding patterns and using individually derived breast milk clearance rates may be readily modelled using this spreadsheet template. Data has been included for many of the most commonly used radiopharmaceuticals and new data can readily be incorporated as it becomes available. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Effect of Pressurized Metered Dose Inhaler Spray Characteristics and Particle Size Distribution on Drug Delivery Efficiency.

    Science.gov (United States)

    Yousefi, Morteza; Inthavong, Kiao; Tu, Jiyuan

    2017-10-01

    A key issue in pulmonary drug delivery is improvement of the delivery device for effective and targeted treatment. Pressurized metered dose inhalers (pMDIs) are the most popular aerosol therapy device for treating lung diseases. This article studies the effect of spray characteristics: injection velocity, spray cone angle, particle size distribution (PSD), and its mass median aerodynamic diameter (MMAD) on drug delivery. An idealized oral airway geometry, extending from mouth to the main bronchus, was connected to a pMDI device. Inhalation flow rates of 15, 30, and 60 L/min were used and drug particle tracking was a one-way coupled Lagrangian model. The results showed that most particles deposited in the pharynx, where the airway has a reduced cross-sectional area. Particle deposition generally decreased with initial spray velocity and with increased spray cone angle for 30 and 60 L/min flow rates. However, for 15 L/min flow rate, the deposition increased slightly with an increase in the spray velocity and cone angle. The effect of spray cone angle was more significant than the initial spray velocity on particle deposition. When the MMAD of a PSD was reduced, the deposition efficiency also reduces, suggesting greater rates of particle entry into the lung. The deposition rate showed negligible change when the MMAD was more than 8 μm. Spray injection angle and velocity change the drug delivery efficacy; however, the efficiency shows more sensitivity to the injection angle. The 30 L/min airflow rate delivers spray particles to the lung more efficiently than 15 and 60 L/min airflow rate, and reducing MMAD can help increase drug delivery to the lung.

  10. Characterization of the spray velocities from a pressurized metered-dose inhaler.

    Science.gov (United States)

    Crosland, Brian Michael; Johnson, Matthew Ronald; Matida, Edgar Akio

    2009-06-01

    Pressurized metered dose inhalers (pMDIs) are widely used to deliver aerosolized medications to the lungs, most often to relieve the symptoms of asthma. Over the past decade, pMDIs have been modified in several ways to eliminate the use of chlorofluorocarbons in their manufacture while increasing efficacy. Numerical simulations are being used more frequently to predict the flow and deposition of particles at various locations, both inside the respiratory tract as well as in pMDIs and add-on devices. These simulations require detailed information about the spray generated by a pMDI to ensure the validity of their results. This paper presents detailed, spatially resolved velocity measurements of the spray emitted from salbutamol sulfate pMDIs obtained using optically triggered particle image velocimetry (PIV). Instantaneous planar velocity measurements were taken and ensemble-averaged at nine different times during the spray event ranging from 1.3 to 100 msec after a pneumatically controlled actuation. The mean spray velocities were shown to be bimodal in time, with two velocity peaks and velocity magnitudes found to be much lower than published data from instantaneous single point measurements. Planar velocity data at each time step were analyzed to produce prescriptive velocity profiles suitable for use in numerical simulations. Spray geometry data are also reported. Statistical comparisons from several thousand individual spray events indicate that there is no significant difference in measured velocity among (1) two brands of pMDI canisters, (2) two pMDIs of the same brand but having different lot numbers, and (3) a full pMDI versus an almost empty pMDI. The addition of a secondary air flow of 30 SLPM (to represent simultaneous inhalation and spray actuation) deflected the spray downward but did not have a significant effect on flow velocity. Further experiments with an added cylindrical spacer revealed that within the spacer, the spray direction and cone angle

  11. Effect of InspirEase on the deposition of metered-dose aerosols in the human respiratory tract

    International Nuclear Information System (INIS)

    Newman, S.P.; Woodman, G.; Clarke, S.W.; Sackner, M.A.

    1986-01-01

    A radiotracer technique has been used to assess the effects of a 700-ml collapsible holding chamber (InspirEase, Key Pharmaceuticals Inc.) on the deposition of metered-dose aerosols in ten patients with obstructive airways disease (mean forced expiratory volume in one second [FEV1], 64.5 percent of predicted). Patterns of deposition obtained by patients' usual techniques with the metered-dose inhaler (MDI) were compared with those by correct MDI technique (actuation coordinated with slow deep inhalation and followed by ten seconds of breath-holding) and with those by InspirEase. Deposition of aerosol was assessed by placing Teflon particles labelled with 99mTc inside placebo canisters, and inhaling maneuvers were monitored by respiratory inductive plethysmography (Respitrace). Nine of the ten patients had imperfect technique with the MDI, the most prevalent errors being rapid inhalation and failure to hold their breath adequately. With patients' usual MDI techniques, 6.5 +/- 1.2 percent (mean +/- SE) of the dose reached the lungs. This was increased to 11.2 +/- 1.3 percent (p less than 0.02) with correct technique and increased further to 14.8 +/- 1.4 percent (p less than 0.05) with InspirEase. Oropharyngeal deposition exceeded 80 percent of the dose for the MDI alone but was only 9.5 +/- 0.9 percent with InspirEase (p less than 0.01); 59.2 +/- 2.1 percent of the dose was retained within InspirEase itself. It is concluded that InspirEase gives whole lung deposition of metered-dose aerosols greater than that from a correctly used MDI, while oropharyngeal deposition is reduced approximately nine times

  12. Dry powder dosing in liquid vehicles: ocular tolerance and scintigraphic evaluation of a perfluorocarbon suspension.

    Science.gov (United States)

    Zhu, Y; Wilson, C G; Meadows, D; Olejnik, O; Frier, M; Washington, N; Musson, R

    1999-11-30

    The ocular tolerance and precorneal disposition of 99mTc-labelled sterile carbon-perfluorodecalin (PFD) and carbon-aqueous suspensions were examined in a cohort of healthy volunteers. Formulations were prepared in PFD or saline using charcoal particles, radiolabelled with [99mTc]diethylenetriaminepentaacetic acid (DTPA) under GMP conditions. Colloidal silicon dioxide was used as a suspending agent. Ocular tolerance was examined following the instillation of each formulation to the eyes of 12 volunteers. The precorneal distribution of both formulations in man was monitored using gamma scintigraphy. Dynamic and static data acquisitions were taken over a period of 150 min after dosing. Carbon particulates suspended in PFD did not show any irritation to the eye. Administration of PFD formulation in man produced a significant increase in ocular retention over a saline formulation (mean residence time (MRT)=157+/-42 and 0.29+/-0.08 min, respectively, P=0.0001). Distribution of the carbon in man followed the same pattern as in a previous reported study in animals. The carbon deposited uniformly along the lid margin in the case of the PFD vehicle, whereas it agglomerated following dosing in the saline vehicle and was ejected from the eye. The novel non-aqueous vehicle system is able to significantly improve the ocular retention of charcoal particles in man and provides a unique distribution of the particles in the eye, which suggests a potential for the PFD system for the treatment of periocular diseases.

  13. Development of 'Dose Rate Meter' android app for radiation detection using camera of smartphones and tablet

    International Nuclear Information System (INIS)

    Shaikh, Aatef; Sharma, M.K.; Kulkarni, M.S.; Romal, Jis; Gupta, A.; Chaudhury, P.

    2018-01-01

    An android app 'Dose Rate Meter' for gamma radiation field measurement over wide range using smart phone has been developed. The android app implements the cluster counting and high delta algorithm. The high delta algorithm processes multiple images captured by the camera. It is more sensitive at lower dose rates but it saturates at higher dose rates of the order of 1Gy/h and its response starts decreasing. Since, this algorithm analyses a number of images to compute the dose rate, it takes few minutes to process on a typical smart phone with 1 GB RAM, dual core processor and a clock in the range of 1GHz. However, the cluster count algorithm computes the results in a few seconds only as it operates on a single image but it can be used to measure dose rate only in the range of 5 mGy/h and above. Therefore, we have implemented the two algorithms in such a way that initially, the control goes to the cluster count algorithm and in case the dose rate is below 5mGy/h, it has provision to invoke the high delta algorithm, thereby covering a dose rate measurement range from μGy/h to Gy/h

  14. Competence in metered dose inhaler technique among community pharmacy professionals in Gondar town, Northwest Ethiopia: Knowledge and skill gap analysis.

    Science.gov (United States)

    Belachew, Sewunet Admasu; Tilahun, Fasil; Ketsela, Tirsit; Achaw Ayele, Asnakew; Kassie Netere, Adeladlew; Getnet Mersha, Amanual; Befekadu Abebe, Tamrat; Melaku Gebresillassie, Begashaw; Getachew Tegegn, Henok; Asfaw Erku, Daniel

    2017-01-01

    When compared to systemic administration, if used correctly inhalers deliver a smaller enough percent of the drug right to the site of action in the lungs, with a faster onset of effect and with reduced systemic availability that minimizes adverse effects. However, the health professionals' and patients' use of metered dose inhaler is poor. This study was aimed to explore community pharmacy professionals' (pharmacists' and druggists') competency on metered dose inhaler (MDI) technique. A cross sectional study was employed on pharmacy professionals working in community drug retail outlets in Gondar town, northwest Ethiopia from March to May 2017. Evaluation tool was originally taken and adapted from the National Asthma Education and Prevention Programmes of America (NAEPP) step criteria for the demonstration of a metered dose inhaler to score the knowledge/proficiency of using the inhaler. Among 70 community pharmacy professionals approached, 62 (32 pharmacists and 30 druggists/Pharmacy technicians) completed the survey with a response rate of 85.6%. Only three (4.8%) respondents were competent by demonstrating the vital steps correctly. Overall, only 13 participants got score seven or above, but most of them had missed the essential steps which included steps 1, 2, 5, 6, 7 or 8. There was a significant difference (P = 0.015) in competency of demonstrating adequate inhalational technique among respondents who took training on basic inhalational techniques and who did not. This study shown that, community pharmacy professionals' competency of MDI technique was very poor. So as to better incorporate community pharmacies into future asthma illness management and optimize the contribution of pharmacists, interventions would emphasis to improve the total competence of community pharmacy professionals through establishing and providing regular educational programs.

  15. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5% compared with branded and generic prednisolone acetate ophthalmic suspension (1%

    Directory of Open Access Journals (Sweden)

    Marlowe ZT

    2013-12-01

    Full Text Available Zora T Marlowe, Stephen R DavioPharmaceutical Product Development, Global Pharmaceutical Research and Development, Bausch and Lomb, Inc, Rochester, NY, USAIntroduction: Loteprednol etabonate (LE ophthalmic gel 0.5% (Lotemax® is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte® and a generic prednisolone acetate suspension 1% were used as comparators.Methods: Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing – consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC method and reported as a percentage of the declared (labeled concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity.Results: Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD] percent declared concentration of 102% (1.92% over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively, with mean concentrations for both falling significantly

  16. Variation in hepatitis B immunization coverage rates associated with provider practices after the temporary suspension of the birth dose

    Directory of Open Access Journals (Sweden)

    Mullooly John P

    2006-11-01

    Full Text Available Abstract Background In 1999, the American Academy of Pediatrics and U.S. Public Health Service recommended suspending the birth dose of hepatitis B vaccine due to concerns about potential mercury exposure. A previous report found that overall national hepatitis B vaccination coverage rates decreased in association with the suspension. It is unknown whether this underimmunization occurred uniformly or was associated with how providers changed their practices for the timing of hepatitis B vaccine doses. We evaluate the impact of the birth dose suspension on underimmunization for the hepatitis B vaccine series among 24-month-olds in five large provider groups and describe provider practices potentially associated with underimmunization following the suspension. Methods Retrospective cohort study of children enrolled in five large provider groups in the United States (A-E. Logistic regression was used to evaluate the association between the birth dose suspension and a child's probability of being underimmunized at 24 months for the hepatitis B vaccine series. Results Prior to July 1999, the percent of children who received a hepatitis B vaccination at birth varied widely (3% to 90% across the five provider groups. After the national recommendation to suspend the hepatitis B birth dose, the percent of children who received a hepatitis B vaccination at birth decreased in all provider groups, and this trend persisted after the policy was reversed. The most substantial decreases were observed in the two provider groups that shifted the first hepatitis B dose from birth to 5–6 months of age. Accounting for temporal trend, children in these two provider groups were significantly more likely to be underimmunized for the hepatitis B series at 24 months of age if they were in the birth dose suspension cohort compared with baseline (Group D OR 2.7, 95% CI 1.7 – 4.4; Group E OR 3.1, 95% CI 2.3 – 4.2. This represented 6% more children in Group D and 9

  17. Oronasal and Tracheostomy Delivery of Soft Mist and Pressurized Metered-Dose Inhalers With Valved Holding Chamber.

    Science.gov (United States)

    Berlinski, Ariel; Cooper, Brandy

    2016-07-01

    Some pediatric tracheostomized patients who receive inhaled drugs undergo decannulation, and it is unknown whether the dose has to be adjusted. Pressurized metered-dose inhalers (pMDIs) and soft mist inhalers (SMIs) used with valved holding chambers (VHCs) made of non-electrostatic material are available. We hypothesized that using an SMI and changing the delivery route from tracheostomy to oronasal would increase lung dose. Four units of a metallic VHC were studied with albuterol hydrofluoroalkane (pMDI) and albuterol/ipratropium bromide with an SMI using an anatomically correct in vitro model of a 5-y-old spontaneously breathing tracheostomized child. The drug was captured in a filter and was termed lung dose. We tested breathing patterns with tidal volumes of 50, 155, and 300 mL. A mask and a special adapter were used as interfaces for oronasal and tracheostomy delivery, respectively. Spectrophotometry (276 nm) was used to determine albuterol concentration. The use of SMI resulted in a higher lung dose than the pMDI for all tested conditions except delivery through tracheostomy with tidal volume of 155 mL (P = .69). Switching from oronasal to tracheostomy delivery increased the lung dose for all tested conditions except for the pMDI with the 300-mL tidal volume (P = .83). The use of SMI resulted in higher deposition in the tracheostomy tube than the pMDI. In general, an SMI delivers a higher lung dose than a pMDI when using a metallic spacer during oronasal and tracheostomy route with the latter providing a higher lung dose. Copyright © 2016 by Daedalus Enterprises.

  18. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5%) compared with branded and generic prednisolone acetate ophthalmic suspension (1%).

    Science.gov (United States)

    Marlowe, Zora T; Davio, Stephen R

    2014-01-01

    Loteprednol etabonate (LE) ophthalmic gel 0.5% (Lotemax®) is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte®) and a generic prednisolone acetate suspension 1% were used as comparators. Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing - consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC) method and reported as a percentage of the declared (labeled) concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity. Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD]) percent declared concentration of 102% (1.92%) over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively), with mean concentrations for both falling significantly below the declared concentration for drops expressed at the beginning of the 2-week dosing regimen and significantly above the declared concentration for drops expressed near the end of the dosing

  19. A patient dose survey or femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    We present a method for dealing with a complex radiographic procedure (which involves multiple radiographs and fluoroscopy) in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. A useful index of harm can be obtained by recording the number of radiographs in each region, and the fluoroscopy time, from which the effective dose may be easily calculated. A patient dose survey was carried out using a PTW diamentor for femoral arteriogram procedures in a large teaching hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. The measurements extend a continuing survey of doses for common diagnostic radiographic examinations which have previously included the simple examinations of lumbar spine, abdomen and pelvis. (Author)

  20. Evaluation of the Metered-Dose Inhaler Technique among Health Care Providers Practicing in Hamadan University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    E. Nadi

    2004-07-01

    Full Text Available Poor inhaler technique is a common problem both in asthma patients and health care providers , which contributes to poor asthma control. The aim of this study was to evaluate the correctness of metered-dose inhaler (MDI technique in a sample of physicians , pharmacists and nurses practicing in Hamadan University hospitals. A total of 176 healthcare providers (35 internists and general physicians , 138 nurses and 3 pharmacists were participated voluntary in this study. After the participants answered a questionnaire aimed at identifying their involvement in MDI prescribing and counseling , a trained observer assessed their MDI technique using a checklist of ten steps.Of the 176 participants , 35(20% were physician , and 3 subjects (2% were pharmacists , and 138 (78% were nurses. However only 6 participants (3.4% performed all steps correctly. Physicians performed significantly better than non-physicians (8.6% vs. 2.13%.The majority of healthcare providers responsible for instructing patients on the correct MDI technique were unable to perform this technique correctly ‘indicating the need for regular formal training programmes on inhaler techniques.

  1. Factors affecting the efficiency of aerosolized salbutamol delivery via a metered dose inhaler and equine spacer device.

    Science.gov (United States)

    Pirie, R S; McGorum, B C; Owen, C; Carr, O; Oakley, H; McLachlan, G

    2017-06-01

    Despite frequent use of metered dose inhalers (MDIs) and spacers in equine practice, limited information exists on the efficiency of aerosol delivery using such devices. We determined the particle size distribution within an MDI-generated salbutamol aerosol delivered via an equine spacer using 'best practice' delivery technique and assessed the effect of variations in MDI use technique (shaking prior to each actuation, rapid repetitive actuations, and MDI angulation) on aerosol delivery efficiency. Under optimal conditions, only 53(±18) μg salbutamol per 100 μg actuation was delivered beyond the spacer. Although this aerosol had a high [89.6% (±2.4)] fine particle (aerodynamic diameter [2.52 (±0.29) μm], and particle size variability [geometric SD - 1.66 (±0.16) μm], within all particle size fractions, there was a high coefficient of variance (31-79%) of the percentage salbutamol delivered between experimental runs, thus impeding any effort to predict drug delivery to the patient during equine inhalation therapy. Despite observable trends and with the exception of minor statistically significant changes in the least abundant particle sizes, none of the deviations from a 'best practice' delivery technique significantly altered the relative salbutamol delivery beyond the spacer, a finding which has potential relevance with regard to maintaining user compliance. © 2016 John Wiley & Sons Ltd.

  2. The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols.

    Science.gov (United States)

    Chen, Yang; Young, Paul M; Fletcher, David F; Chan, Hak Kim; Long, Edward; Lewis, David; Church, Tanya; Traini, Daniela

    2015-04-01

    To investigate the influence of different actuator nozzle designs on aerosol electrostatic charges and aerosol performances for pressurised metered dose inhalers (pMDIs). Four actuator nozzle designs (flat, curved flat, cone and curved cone) were manufactured using insulating thermoplastics (PET and PTFE) and conducting metal (aluminium) materials. Aerosol electrostatic profiles of solution pMDI formulations containing propellant HFA 134a with different ethanol concentration and/or model drug beclomethasone dipropionate (BDP) were studied using a modified electrical low-pressure impactor (ELPI) for all actuator designs and materials. The mass of the deposited drug was analysed using high performance liquid chromatography (HPLC). Both curved nozzle designs for insulating PET and PTFE actuators significantly influenced aerosol electrostatics and aerosol performance compared with conducting aluminium actuator, where reversed charge polarity and higher throat deposition were observed with pMDI formulation containing BDP. Results are likely due to the changes in plume geometry caused by the curved edge nozzle designs and the bipolar charging nature of insulating materials. This study demonstrated that actuator nozzle designs could significantly influence the electrostatic charges profiles and aerosol drug deposition pattern of pMDI aerosols, especially when using insulating thermoplastic materials where bipolar charging is more dominant.

  3. Effect of low-dose gamma radiation on individual phospholipids in aqueous suspension

    International Nuclear Information System (INIS)

    Tinsley, P.W.; Maerker, G.

    1993-01-01

    A series of individual phospholipids (phosphatidylcholines, phosphatidylethanolamines, phosphatidylserines and phosphatidylglycerols) containing either saturated or unsaturated fatty acid chains was irradiated at 9.66 kgy and 0.4 degree C in aqueous suspension. The phospholipids were analyzed by normal-phase high-performance liquid chromatography on a silica column with an evporative light scattering detector. Phospholipid disppearance and production of two radiolytic products, phosphatidic acid and the lysophospholipid, after irradiation were quantitated from calibration curves of synthetic standards. Dipalmitoylphosphatidic acid and monopalmitoylphosphatidylcholine from irradiated dipalmitoylphosphatidylcholine were identified by liquid secondary-ion mass spectrometry

  4. Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    Science.gov (United States)

    Alatrash, Abubaker; Matida, Edgar

    2016-12-01

    Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic obstructive pulmonary disease. Since their introduction in the field, and as a result of their effectiveness and simplicity of usage, pMDIs are considered to be the most widely prescribed medical aerosol delivery system. In the current study, particle velocity and size distribution were measured at three different locations along the centerline of a pMDI spray using Phase Doppler Anemometry. pMDIs from four different pharmaceutical companies were tested, each using salbutamol sulfate as the medication. Measurements along at the pMDI centerline (at 0, 75, and 100 mm downstream of the inhaler mouthpiece) showed that the spray velocities were bimodal in time for all four pMDI brands. The first peak occurred as the spray was leaving the mouthpiece, while the second peak (at the same location, 0 mm) occurred at around 60, 95, 95, and 115 milliseconds later, respectively, for the four tested inhalers, with a drop in the velocity between the two peaks. Three probability density functions (PDFs) were tested, and the Rosin-Rammler PDF best fit the empirical data, as determined using a chi-squared test. These results suggest that there is a difference in the mean particle velocities at the centerline for the tested pMDIs and the diameter of released particles varied statistically for each brand.

  5. Reverse water-in-fluorocarbon emulsions for use in pressurized metered-dose inhalers containing hydrofluoroalkane propellants.

    Science.gov (United States)

    Butz, N; Porté, C; Courrier, H; Krafft, M P; Vandamme, Th F

    2002-05-15

    Pulmonary administration of drugs has demonstrated numerous advantages in the treatment of pulmonary diseases due to direct targeting to the respiratory tract. It enables avoiding the first pass effect, reduces the amount of drugs administered, targets drugs to specific sites and reduces their side effects. Reverse water-in-fluorocarbon (FC) emulsions are potential drug delivery systems for pulmonary administration using pressurized metered-dose inhalers (pMDI). The external phase of these emulsions consists of perfluorooctyl bromide (PFOB, perflubron), whereas their internal phase contains the drugs solubilized or dispersed in water. These emulsions are stabilized by a perfluoroalkylated dimorpholinophosphate (F8H11DMP), i.e. a fluorinated surfactant. This study demonstrates the possibility of delivering a reverse fluorocarbon emulsion via the pulmonary route using a CFC-free pMDI. Two hydrofluoroalkanes (HFAs) (Solkane(R) 134a and Solkane(R) 227) were used as propellants, and various solution (or emulsion)/propellant ratios (1/3, 1/2, 2/3, 1/1, 3/2, 3/1 v/v) were investigated. The insolubility of water (with or without the fluorinated surfactant F8H11DMP) in both HFA 227 and HFA 134a was demonstrated. PFOB and the reverse emulsion were totally soluble or dispersible in all proportions in both propellants. This study demonstrated also that the reverse FC emulsion can be successfully used to deliver caffeine in a homogeneous and reproducible way. The mean diameter of the emulsion water droplets in the pressured canister was investigated immediately after packaging and after 1 week of storage at room temperature. Best results were obtained with emulsion/propellant ratios comprised between 2/3 and 3/2, and with HFA 227 as propellant.

  6. The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

    Science.gov (United States)

    Chen, Yang; Young, Paul M; Fletcher, David F; Chan, Hak Kim; Long, Edward; Lewis, David; Church, Tanya; Traini, Daniela

    2014-05-01

    To investigate the influence of different actuator materials and nozzle designs on the electrostatic charge properties of a series of solution metered dose inhaler (pMDI) aerosols. Actuators were manufactured with flat and cone nozzle designs using five different materials from the triboelectric series (Nylon, Polyethylene terephthalate, Polyethylene-High density, Polypropylene copolymer and Polytetrafluoroethylene). The electrostatic charge profiles of pMDI containing beclomethasone dipropionate (BDP) as model drug in HFA-134a propellant, with different concentrations of ethanol were studied. Electrostatic measurements were taken using a modified electrical low-pressure impactor (ELPI) and the deposited drug mass assayed chemically using HPLC. The charge profiles of HFA 134a alone have shown strong electronegativity with all actuator materials and nozzle designs, at an average of -1531.34 pC ± 377.34. The presence of co-solvent ethanol significantly reduced the negative charge magnitude. BDP reduced the suppressing effect of ethanol on the negative charging of the propellant. For all tested formulations, the flat nozzle design showed no significant differences in net charge between different actuator materials, whereas the charge profiles of cone designs followed the triboelectric series. The electrostatic charging profiles from a solution pMDI containing BDP and ethanol can be significantly influenced by the actuator material, nozzle design and formulation components. Ethanol concentration appears to have the most significant impact. Furthermore, BDP interactions with ethanol and HFA have an influence on the electrostatic charge of aerosols. By choosing different combinations of actuator materials and orifice design, the fine particle fractions of formulations can be altered.

  7. Potential radiation doses likely to be received by the radiologists and paramedical staff in typical hospital in Pakistan (GM counter, survey meter measurements) (abstract)

    International Nuclear Information System (INIS)

    Ali, A.; Zeb, J.; Iqbal, S.; Orfi, S.D.

    1998-01-01

    Potential radiation doses likely to be received by the radiologists and para medical staff in a typical hospital in Pakistan have been measured using a very sensitive radiation survey meter (FAG FH40F2) employing a Geiger Muller counter (FHZ120) as a probe which is a probe extend able up to 4 meters in length. These measurements have been compared with internationally accepted Maximum Permissible Radiation Dose Level (MPDL). Radiation dose rates measured on the hands of two radiologists during fluoroscopy examination of the patient were of the order of 1mSv.h/sup -1/ and 540 mu Sv.h/sup -1/ which were 400% to 216% times higher than the MPDL (250 mu Sv.h/sup -1/). Radiation dose rates measured on the chest and neck were 300 and 50 mu Sv.h/sup -1/, which were 3000% to 500% times higher than those of MPDL (10 mu Sv.h/sup -1/. Such high dose rates present a serious situation and deserve attention of the hospital management and of national regulatory authority so as to minimize the potential radiation doses to the radiologists and para medical staff. As Low As Reasonably Achievable (ALARA) concept should be implemented in the health sector. (author)

  8. Nuclear Enterprises portable dose rate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The performance characteristics of Nuclear Enterprises Portable Dose Rate Meter Type PDR4 are evaluated under the headings: general description, facilities and controls, radiation characteristics, electrical characteristics, environmental characteristics, mechanical characteristics, the manual, summary of performance, and conclusions. Results of an investigation of the radiation characteristics of the external probes Type BP1/1, Type BP8, and Type GP9 are also detailed. (U.K.)

  9. Potential radiation doses likely to be received by the radiologists and para medical staff in an hospital in Pakistan. (G. M. counter, survey meter measurements )

    International Nuclear Information System (INIS)

    Ali, A.; Zeb, J.; Iqbal, S.; Orfi, S.D.

    1999-01-01

    Potential radiation doses likely to received by the radiologists and paramedical staff in a typical hospital in Pakistan have been measured using a very sensitive radiation survey meter (FAG FH40F2) employing in Geiger Muller counter (FHZ 120] as a role which is extendable up to 4 meters in length. The measurements have been compared with internationally accepted Maximum Permissible Radiation Dos Level (MPDL). Radiation dose rates measured on the hands of two radiologist during fluoroscopy examination of the patient were of the order of 1 m Sv.h/sup -1/ and 540 u Sv. h/sup -1/ which were 400% to 21% higher than the MPDL (250 u Sv. h/sup -1/). Radiation dose rates measured on the chest of the nurses were 300 and 50 u Sv. h/sup -1/, which were 3000% to 500% higher than those of MPDL(10 u Sv. h/sup -1/). Such high dose rates present a serious situation from radiation damage point of view and deserve attention of the hospital management and of national regulatory authority so as to minimize the potential radiation doses to the radiologists and paramedical staff. As Low As Reasonably Achievable (ALARA) concept should be implemented in the health sector. (author)

  10. Deposition and transport of linezolid mediated by a synthetic surfactant Synsurf® within a pressurized metered dose inhaler: a Calu-3 model

    Science.gov (United States)

    van Rensburg, Lyné; van Zyl, Johann M; Smith, Johan

    2018-01-01

    Background Previous studies in our laboratory demonstrated that a synthetic peptide containing lung surfactant enhances the permeability of chemical compounds through bronchial epithelium. The purpose of this study was to test two formulations of Synsurf® combined with linezolid as respirable compounds using a pressurized metered dose inhaler (pMDI). Methods Aerosolization efficiency of the surfactant-drug microparticles onto Calu-3 monolayers as an air interface culture was analyzed using a Next Generation Impactor™. Results The delivered particles and drug dose showed a high dependency from the preparation that was aerosolized. Scanning electron microscopy imaging allowed for visualization of the deposited particles, establishing them as liposomal-type structures (diameter 500 nm to 2 μm) with filamentous features. Conclusion The different surfactant drug combinations allow for an evaluation of the significance of the experimental model system, as well as assessment of the formulations providing a possible noninvasive, site-specific, delivery model via pMDI.

  11. Flattening the Energy Response of a Scintillator Based Gamma Dose Rate Meter Coupled to SiPM

    International Nuclear Information System (INIS)

    Knafo, Y.; Manor, A.; Ginzburg, D.; Ellenbogen, M.; Osovizky, A.; Wengrowicz, U.; Ghelman, M.; Seif, R.; Mazor, T.; Kadmon, Y.; Cohen, Y.

    2014-01-01

    Among the newest emerging technologies that are used in the design of personal gamma radiation detection instruments, the silicon photomultiplier (SiPM) light sensor is playing an important role. This type of photo sensor is characterized by low power consumption, small dimensions and high gain. These special characteristics present applicable alternatives for the replacement of traditional gamma sensors based on scintillator coupled to Photomultiplier tubes (PMT) or on Geiger-Muller(G.M.) sensors. For health physics applications, flat energy response is required for a wide range of radio-nuclides emitting gamma rays of different energies. Scintillation based radiation instrumentation provides count rate and amplitude of the measured pulses. These pulses can be split in different bins corresponding to the energy of the measured isotopes and their intensity. The count rate and the energy of the measured events are related to the dose rate. The conversion algorithm applys a different calibration factor for each energy bin in order to provide an accurate dose rate response for a wide range of gamma energies. This work describes the utilization of an innovative approach for dose rate conversion by using the abilities of newest 32-bit microcontroller based ARM core architecture

  12. Cost-effectiveness of fluticasone propionate administered via metered-dose inhaler plus babyhaler spacer in the treatment of asthma in preschool-aged children

    DEFF Research Database (Denmark)

    Bisgaard, H; Price, M J; Maden, Christian Nicolai

    2001-01-01

    a metered-dose inhaler and a Babyhaler (Glaxo Wellcome; Middlesex, UK) spacer device. MEASUREMENTS: Effectiveness in terms of asthma exacerbations, control of cough and wheeze symptoms, symptom-free days, overall direct costs of asthma management in Danish kroner at 1999 prices, and mean and incremental......STUDY OBJECTIVES: To evaluate the cost-effectiveness of inhaled fluticasone propionate (FP) in children aged 12 to 47 months with asthma symptoms. DESIGN: A retrospective economic analysis conducted from the perspective of the Danish health-care system, based on clinical data from a 12-week study...... cost-effectiveness ratios. RESULTS: FP, 200 microg/d, was significantly more effective than placebo treatment in terms of the proportion of exacerbation-free patients (73.7% vs 59.8%; p = 0.025) and patients experiencing a > or = 25% improvement in cough symptoms (57.9% vs 39.0%; p = 0.018). The costs...

  13. Specific activities and the relevant gamma ray dose rates at 1 meter from radioisotopes and isomers following thermal neutron capture reaction

    International Nuclear Information System (INIS)

    Eissa, E.A.; Aly, R.A.; Gomaa, M.A.; Hassan, A.M.

    1995-01-01

    Calculations were performed for the specific activity of 245 gamma-ray emitting radioisotopes and isomers produced in 48, 72 and 96 hour irradiation periods of the natural isotopic mixture of their 77 elements with thermal neutron flux 1.0 E + 13 n/cm 2 .5, at the core of the (ET-R R-1) reactor. The relevant gamma-ray dose rate at a point 1 meter apart from each radioisotope or isomer was evaluated whenever the specific gamma-ray dose rate constant is available. The irradiation time factor (ITF) for the irradiation periods 24, 48, 72 and 96 hours are reported for each of the 248 gamma-ray emitters. The average of (ITF) over these 248 radionuclides for each irradiation period is taken as a measure of the feasibility of the irradiation time. The results favour the increase of the irradiation period from the conventional 48 to 72 hours but not to 96 hours. A programme was established in the VAX computer to carry out the above mentioned calculations. Tables of the present work are very useful for isotope production and reactor safety. 1 fig., 2 tabs

  14. Charge Meter

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 4. Charge Meter: Easy Way to Measure Charge and Capacitance: Some Interesting Electrostatic Experiments. M K Raghavendra V Venkataraman. Classroom Volume 19 Issue 4 April 2014 pp 376-390 ...

  15. Solid state semiconductor detectorized survey meter

    International Nuclear Information System (INIS)

    Okamoto, Eisuke; Nagase, Yoshiyuki; Furuhashi, Masato

    1987-01-01

    Survey meters are used for measurement of gamma ray dose rate of the space and the surface contamination dencity that the atomic energy plant and the radiation facility etc. We have recently developed semiconductor type survey meter (Commercial name: Compact Survey Meter). This survey meter is a small-sized dose rate meter with excellent function. The special features are using semiconductor type detector which we have developed by our own technique, stablar wide range than the old type, long life, and easy to carry. Now we introduce the efficiency and the function of the survey meter. (author)

  16. Efficacy and safety of ipratropium bromide/salbutamol sulphate administered in a hydrofluoroalkane metered-dose inhaler for the treatment of COPD

    Directory of Open Access Journals (Sweden)

    Bhattacharya A

    2016-06-01

    Full Text Available Amal Bhattacharya,1 Salil Bhargava,2 Virendra Singh,3 Deepak Talwar,4 Jagdeep Whig,5 Juliet Rebello,6 Shrinivas Purandare,6 Jaideep Gogtay6 1Department of Medicine, MP Shah Medical College, Jamnager, Gujarat, 2Tuberculosis and Chest Diseases, MGM Medical College, Indore, Madhya Pradesh, 3Pulmonary Division, SMS Hospital, Jaipur, Rajasthan, 4Respiratory Diseases, Metro Hospital and Heart Institute, Noida, Uttar Pradesh, 5Department of Medicine, Dayanand Medical College & Hospital, Ludhiana, Punjab, 6Clinical Research Department, Cipla Ltd, Mumbai, Maharashtra, India Background: The use of chlorofluorocarbons (CFCs has contributed to the depletion of the stratospheric ozone layer resulting in serious health concerns. Ipratropium bromide/salbutamol sulphate CFC-pressurized metered-dose inhalers (IB/SAL-CFC pMDI have been in widespread use for many years without any apparent ill consequences. This combination has now been reformulated using the hydrofluoroalkane (HFA propellant. This study sought to establish the clinical noninferiority of a new HFA-containing IB/SAL pMDI to the conventional IB/SAL-CFC pMDI in subjects with mild/moderate COPD.Methods: This was a randomized, double-blind, parallel-group, multicenter study in two consecutive periods: a 14-day run-in period followed by a 85-day treatment period. Eligible mild-to-moderate stable COPD subjects aged 40-75 years were enrolled into the study and entered the run-in period during which subjects withdrew all the bronchodilators, except for salbutamol as rescue medication. Subjects were randomized to 85 days treatment with either IB/SAL-HFA or IB/SAL-CFC, 20 µg qid.Results: Of the 290 randomized patients, 249 completed the study. The primary efficacy variable was the change in forced expiratory volume in one second from predose to 60 minutes after dosing on day 85. At the end of the treatment period, the adjusted mean change in forced expiratory volume in one second at 60 minutes was 123

  17. Effect of different single-session educational modalities on improving medical students' ability to demonstrate proper pressurized metered dose inhaler technique.

    Science.gov (United States)

    Dominelli, Giulio S; Dominelli, Paolo B; Rathgeber, Steven L; Webster, Sheila B

    2012-05-01

    Pressurized metered dose inhalers (pMDIs) remain important therapeutic options for obstructive lung diseases. The ability to instruct and evaluate inhaler technique is a crucial skill that all medical professionals should possess; unfortunately, many professionals lack proficiency with pMDIs. We aimed to determine if brief education interventions of differing modalities can positively affect medical students' skills over the long term. The baseline ability of medical students and first year residents to use pMDIs was scored via a 10-point scoring system. Students were randomized to receive no education, one-on-one instruction, or video instruction. Students were then retested immediately after the education and at the 3-month mark for retention of acquired skills. Video, one-on-one and the placebo groups modalities statistically improved the average medical student's score in the immediate retesting (7.5 and 7.4 vs. 4.7, p grades at the immediate recall significantly improved for both modalities. During retention testing, only video education had a statistically significant improvement in pass rate over the control group, as defined by an average score of 7 or better (8 vs. 1, p improve medical students' ability to use pMDIs in short-term testing. However, only video education retained significant improvement compared with control after 3 months. This suggests that compared with traditional one-on-one teaching, video education is an effective means of teaching medical students how to improve their pMDI technique.

  18. The effect of ethanol on the formation and physico-chemical properties of particles generated from budesonide solution-based pressurized metered-dose inhalers.

    Science.gov (United States)

    Zhu, Bing; Traini, Daniela; Chan, Hak-Kim; Young, Paul M

    2013-11-01

    The aerosol performance of budesonide solution-based pressurized metered-dose inhalers (HFA 134a), with various amounts of ethanol (5-30%, w/w) as co-solvents, was evaluated using impaction and laser diffraction techniques. With the increase of ethanol concentration in a formulation, the mass median aerodynamic diameter was increased and the fine particle fraction showed a significant decline. Although data obtained from laser diffraction oversized that of the impaction measurements, good correlations were established between the two sets of data. Particles emitted from all the five formulations in this study were amorphous, with two different types of morphology - the majority had a smooth surface with a solid core and the others were internally porous with coral-like surface morphology. The addition of ethanol in the formulation decreased the percentage of such irregular-shape particles from 52% to 2.5% approximately, when the ethanol concentration was increased from 5% to 30%, respectively. A hypothesis regarding the possible particle formation mechanisms was also established. Due to the difference of droplet composition from the designed formulation during the atomization process, the two types of particle may have gone through distinct drying processes: both droplets will have a very short period of co-evaporation, droplets with less ethanol may be dried during such period; while the droplets containing more ethanol will undergo an extra condensation stage before the final particle formation.

  19. Metered dose inhaler use - slideshow

    Science.gov (United States)

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  20. Treatment with budesonide/formoterol pressurized metered-dose inhaler in patients with asthma: a focus on patient-reported outcomes

    Directory of Open Access Journals (Sweden)

    Richard D O'Connor

    2011-01-01

    Full Text Available Richard D O'ConnorSharp Rees-Stealy Medical Group, San Diego, CA, USAAbstract: In the United States, budesonide/formoterol pressurized metered-dose inhaler (pMDI is approved for treatment of asthma in patients aged ≥12 years whose asthma is not adequately controlled with an inhaled corticosteroid (ICS or whose disease severity clearly warrants treatment with an ICS and a long-acting β2-adrenergic agonist. This article reviews studies of budesonide/formoterol pMDI in patients with persistent asthma, with a particular focus on patient-reported outcomes (eg, perceived onset of effect, patient satisfaction with treatment, health-related quality of life [HRQL], global assessments, sleep quality and quantity, as these measures reflect patient perceptions of asthma control and disease burden. A search of PubMed and respiratory meetings was performed to identify relevant studies. In two pivotal budesonide/formoterol pMDI studies in adolescents and adults, greater efficacy and similar tolerability were shown with budesonide/formoterol pMDI 160/9 µg and 320/9 µg twice daily versus its monocomponents or placebo. In those studies, improvements in HRQL, patient satisfaction, global assessments of asthma control, and quality of sleep also favored budesonide/formoterol pMDI compared with one or both of its monocomponents or placebo. Budesonide/formoterol pMDI has a rapid onset of effect (within 15 minutes that patients can feel, an attribute that may have benefits for treatment adherence. In summary, budesonide/formoterol pMDI is effective and well tolerated and has additional therapeutic benefits that may be important from the patient’s perspective.Keywords: budesonide, formoterol, patient-reported outcomes, efficacy, tolerability, onset of effect

  1. Relative bioavailability of single doses of prolonged-release tacrolimus administered as a suspension, orally or via a nasogastric tube, compared with intact capsules: a phase 1 study in healthy participants.

    Science.gov (United States)

    Undre, Nasrullah; Dickinson, James

    2017-04-04

    Tacrolimus, an immunosuppressant widely used in solid organ transplantation, is available as a prolonged-release capsule for once-daily oral administration. In the immediate postsurgical period, if patients cannot take intact capsules orally, tacrolimus therapy is often initiated as a suspension of the capsule contents, delivered orally or via a nasogastric tube. This study evaluated the relative bioavailability of prolonged-release tacrolimus suspension versus intact capsules in healthy participants. A phase 1, open-label, single-dose, cross-over study. A single clinical research unit. In total, 20 male participants, 18-55 years old, entered and completed the study. All participants received nasogastric administration of tacrolimus 10 mg suspension in treatment period 1, with randomisation to oral administration of suspension or intact capsules in periods 2 and 3. Blood concentration-time profile over 144 hours was used to estimate pharmacokinetic parameters. Primary end point: relative bioavailability of prolonged-release intact capsule versus oral or nasogastric administration of prolonged-release tacrolimus suspension (area under the concentration-time curve (AUC) from time 0 to infinity post-tacrolimus dose (AUC 0-∞ ); AUC measured until the last quantifiable concentration (AUC 0-tz ); maximum observed concentration (C max ); time to C max (T max )). Tolerability was assessed throughout the study. Relative bioavailability of prolonged-release tacrolimus suspension administered orally was similar to intact capsules, with a ratio of least-square means for AUC 0-tz and AUC 0-∞ of 1.05 (90% CI 0.96 to 1.14). Bioavailability was lower with suspension administered via a nasogastric tube versus intact capsules (17%; ratio 0.83; CI 0.76 to 0.92). C max was higher for oral and nasogastric suspension (30% and 28%, respectively), and median T max was shorter (difference 1.0 and 1.5 hours postdose, respectively) versus intact capsules (2.0 hours). Single 10

  2. Spectral correction factors for conventional neutron dose meters used in high-energy neutron environments improved and extended results based on a complete survey of all neutron spectra in IAEA-TRS-403

    International Nuclear Information System (INIS)

    Oparaji, U.; Tsai, Y. H.; Liu, Y. C.; Lee, K. W.; Patelli, E.; Sheu, R. J.

    2017-01-01

    This paper presents improved and extended results of our previous study on corrections for conventional neutron dose meters used in environments with high-energy neutrons (E n > 10 MeV). Conventional moderated-type neutron dose meters tend to underestimate the dose contribution of high-energy neutrons because of the opposite trends of dose conversion coefficients and detection efficiencies as the neutron energy increases. A practical correction scheme was proposed based on analysis of hundreds of neutron spectra in the IAEA-TRS-403 report. By comparing 252 Cf-calibrated dose responses with reference values derived from fluence-to-dose conversion coefficients, this study provides recommendations for neutron field characterization and the corresponding dose correction factors. Further sensitivity studies confirm the appropriateness of the proposed scheme and indicate that (1) the spectral correction factors are nearly independent of the selection of three commonly used calibration sources: 252 Cf, 241 Am-Be and 239 Pu-Be; (2) the derived correction factors for Bonner spheres of various sizes (6''-9'') are similar in trend and (3) practical high-energy neutron indexes based on measurements can be established to facilitate the application of these correction factors in workplaces. (authors)

  3. Field Evaluation of Low-Dose Metering and Polymer Endothall Applications and Comparison of Fluridone Degradation from Liquid and Slow-Release Pellet Applications

    National Research Council Canada - National Science Library

    Netherland, Michael

    1998-01-01

    ... vary greatly within a 24-hr period. In addition to metering technology, a new granular supersorbent polymer formulation of endothall that contains 61 percent active ingredient was evaluated in Lake Weohyapapka, Florida...

  4. Advanced Metering Infrastructure based on Smart Meters

    Science.gov (United States)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  5. Broncodilatadores en la crisis asmática: ¿Aerosol o nebulización? Bronchodilators in acute asthma: metered dose inhalers or wet nebulizations?

    Directory of Open Access Journals (Sweden)

    Dora M. Lombardi

    2006-12-01

    Full Text Available El número de consultas por asma aguda en el Hospital María Ferrer ha aumentado de 3300 consultas anuales en 1980 a 15364 en 2002. Los broncodilatadores de acción corta (salbutamol-ipratropio en nebulizaciones, procedimiento que consume tiempo y recursos humanos, eran el tratamiento inicial en 2002. Para tratar de mejorar el cumplimiento del tratamiento frente al aumento de la demanda, se reemplazaron las nebulizaciones por aerosoles dosificadores. El objetivo de este estudio es evaluar el impacto de este cambio. Comparamos 90 pacientes con crisis asmática tratados con aerosoles en diciembre del 2003 con igual número tratados con nebulizaciones en diciembre del 2002 pareados por sexo, edad, altura, VEF1 teórico y de ingreso. Con aerosoles se observó una reducción significativa del tiempo de permanencia en el Departamento de Emergencia (mediana 3 h (2-4.75 versus 4 h (1-6 p=0.01 y un número mayor de altas en las primeras 2 horas (48% vs. 31% p=0.03. Los pacientes tratados con aerosol recibieron el 87% de las dosis prescriptas, mientras que el otro grupo recibió sólo el 38%. El VEF1 mostró una tendencia a ser mayor al egreso en el grupo que recibió aerosoles, pero la diferencia no fue estadísticamente significativa (78% ± 17% vs. 73% ± 17% p=0.09. El porcentaje de alta final fue similar en los dos grupos (96% vs. 93%. El tratamiento con aerosoles produjo una mejoría más rápida y mejor cumplimiento de las normas de tratamiento indicadas.The number of patients attending our Emergency Department (ED with acute asthma has increased from 3300 patient/year in 1980 to 15364 in 2003. Short acting bronchodilators (albuterol/ipratropium administered in wet nebulizations, a resource consuming procedure, were our main initial treatment in 2002. To improve treatment goals, we switched the method of bronchodilator delivery to metered dose inhalers (MDI in 2003. The purpose of this study is to evaluate the impact of this change in the

  6. Randomized, open-label, single-dose, crossover, relative bioavailability study in healthy adults, comparing the pharmacokinetics of rabeprazole granules administered using soft food or infant formula as dosing vehicle versus suspension.

    Science.gov (United States)

    Thyssen, An; Solanki, Bhavna; Treem, William

    2012-07-01

    A sprinkle capsule formulation containing enteric-coated, delayed-release rabeprazole granules is being developed for the treatment of children with gastrointestinal reflux disease. The granules are designed to be mixed with vehicles that facilitate delivery to children, who may be unable to swallow solid formulations. The primary objective of this study-conducted on the sponsor's initiative-was to compare the bioavailability of rabeprazole granules when mixed with various dosing vehicles (small amount of soft food or infant formula) with that of a rabeprazole suspension with inactive vehicle granules (reference), to determine which dosing vehicle can be used to deliver rabeprazole in children. Tolerability was also assessed. This single-center, single-dose, randomized, open-label, 5-period crossover study was conducted in 35 healthy adult subjects. In a randomized sequence, fasting subjects received a single dose of 10-mg rabeprazole granules per treatment period, mixed with small amounts of 1 of 5 dosing vehicles (a strawberry-flavored suspension of rabeprazole granules with inactive vehicle granules reconstituted with water, yogurt [1 tablespoon], applesauce [1 tablespoon], or infant formula [5 mL], or a suspension of rabeprazole granules with inactive vehicle tablet reconstituted with water). Full plasma pharmacokinetic (PK) profiles of rabeprazole and its thioether metabolite were collected; concentrations were estimated via LC-MS/MS. PK properties were estimated using noncompartmental methods; 90% CIs around least squares mean test-to-reference ratios were calculated for C(max) and AUC values. All treatment-emergent adverse events (TEAEs) were recorded and assessed for severity (mild, moderate, or severe) and relationship to study drug. A total of 35 subjects were enrolled (mean age, 38 years; 54.3% female; 100% white; mean weight, 71.4 kg). Thirty-four subjects completed the study. Rabeprazole and rabeprazole thioether plasma PK properties were comparable

  7. TPP-dendrimer nanocarriers for siRNA delivery to the pulmonary epithelium and their dry powder and metered-dose inhaler formulations.

    Science.gov (United States)

    Bielski, Elizabeth; Zhong, Qian; Mirza, Hamad; Brown, Matthew; Molla, Ashura; Carvajal, Teresa; da Rocha, Sandro R P

    2017-07-15

    The regulation of genes utilizing the RNA interference (RNAi) mechanism via the delivery of synthetic siRNA has great potential in the treatment of a variety of lung diseases. However, the delivery of siRNA to the lungs is challenging due to the poor bioavailability of siRNA when delivered intraveneously, and difficulty in formulating and maintaining the activity of free siRNA when delivered directly to the lungs using inhalation devices. The use of non-viral vectors such as cationic dendrimers can help enhance the stability of siRNA and its delivery to the cell cytosol. Therefore, in this work, we investigate the ability of a triphenylphosphonium (TPP) modified generation 4 poly(amidoamine) (PAMAM) dendrimer (G4NH 2 -TPP) to enhance the in vitro transfection efficiency of siRNA in a model of the pulmonary epithelium and their aerosol formulations in pressurized metered dose inhalers (pMDIs) and dry powder inhalers (DPIs). Complexes of siRNA and G4NH 2 -TPP were prepared with varying TPP densities and increasing N/P ratios. The complexation efficiency was modulated by the presence of the TPP on the dendrimer surface, allowing for a looser complexation compared to unmodified dendrimer as determined by gel electrophoresis and polyanion competition assay. An increase in TPP density and N/P ratio led to an increase in the in vitro gene knockdown of stably green fluorescent protein (eGFP) expressing lung alveolar epithelial (A549) cells. G4NH 2 -12TPP dendriplexes (G4NH 2 PAMAM dendrimers containing 12 TPP molecules on the surface complexed with siRNA) at N/P ratio 30 showed the highest in vitro gene knockdown efficiency. To assess the potential of TPP-dendriplexes for pulmonary use, we also developed micron particle technologies for both pMDIs and DPIs and determined their aerosol characteristics utilizing an Andersen Cascade Impactor (ACI). Mannitol microparticles encapsulating 12TPP-dendriplexes were shown to be effective in producing aerosols suitable for deep lung

  8. Cellular internalization and transport of biodegradable polyester dendrimers on a model of the pulmonary epithelium and their formulation in pressurized metered-dose inhalers.

    Science.gov (United States)

    Heyder, Rodrigo S; Zhong, Qian; Bazito, Reinaldo C; da Rocha, Sandro R P

    2017-03-30

    The purpose of this study was to evaluate the effect of generation and surface PEGylation of degradable polyester-based dendrimers nanocarriers on their interactions with an in vitro model of the pulmonary epithelium as well as to assess the ability to formulate such carriers in propellant-based, portable oral-inhalation devices to determine their potential for local and systemic delivery of drugs to and through the lungs. Hydroxyl (-OH) terminated polyester dendrimers of generation 3 and 4 (G3, and G4) were synthesized using a divergent approach. G4 was surface-modified with PEG (1,000Da). All dendrimers and their building blocks were determined to be highly compatible with the model pulmonary epithelium, with toxicity profiles much more favorable than non-degradable polyamidoamine dendrimers (PAMAM). The transport of the species from the apical to basolateral side across polarized Calu-3 monolayers showed to be generation and surface-chemistry (PEGylation) dependent. The extent of the transport is modulated by their interaction with the polarized epithelium and their transient opening of the tight junctions. G3 was the one most efficiently internalized by the epithelium, and had a small impact on the integrity of the monolayer. On the other hand, the PEGylated G4 was the one least internalized by the polarized epithelium, and at the same time had a more pronounced transient impact on the cellular junctions, resulting in more efficient transport across the cell monolayer. PEGylation of the dendrimer surface played other roles as well. PEGylation modulated the degradation profile of the dendrimer, slowing the process in a step-wise fashion - first the PEG layer is shed and then the dendrimer starts degrading. PEGylation also helped increase the solvation of the nanocarriers by the hydrofluoroalkane propellant used in pressurized metered-dose inhalers, resulting in formulations with excellent dispersibility and aerosol quality (deep lung deposition of 88

  9. Radiation meter

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1990-05-30

    Measuring means comprising first and second silicon PIN diode detectors both being covered with a thin layer of conducting material and the second detector being additionally covered with a relatively thick layer of material, the thickness being chosen such that beta radiation dose rate can be measured in beta radiation fields of high or medium energy, and in the presence of X and gamma radiation. (author). 2 figs.

  10. Efficacy and Safety of Multiple Doses of Exenatide Once-Monthly Suspension in Patients With Type 2 Diabetes: A Phase II Randomized Clinical Trial.

    Science.gov (United States)

    Wysham, Carol H; MacConell, Leigh; Hardy, Elise

    2016-10-01

    This study investigated the efficacy and safety of multiple exenatide once-monthly suspension (QMS) doses of exenatide-containing microspheres in Miglyol referenced against the clinical dose of exenatide once-weekly (QW) microspheres in aqueous solution. In this phase II, randomized, controlled, single-blind study, 121 adults (∼30/arm) with type 2 diabetes and HbA1c 7.1-11.0% (54-97 mmol/mol) were randomized 1:1:1:1 to subcutaneous exenatide QW 2 mg (self-administered) or exenatide QMS 5, 8, or 11 mg (caregiver-administered) for 20 weeks. The primary end point was change in HbA1c. At baseline, mean age was 50 years, HbA1c was 8.5% (69 mmol/mol), fasting plasma glucose (FPG) was 184 mg/dL, and body weight was 98 kg. At week 20, mean ± SD HbA1c reductions were -1.54% ± 1.26% with exenatide QW and -1.29% ± 1.07%, -1.31% ± 1.66%, and -1.45% ± 0.93% with exenatide QMS 5, 8, and 11 mg, respectively (evaluable population: n = 110). There were no significant differences in HbA1c reductions among the exenatide QMS doses. FPG reductions were -34 ± 48 mg/dL with exenatide QW and -25 ± 43, -30 ± 52, and -49 ± 49 mg/dL with exenatide QMS 5, 8, and 11 mg, respectively. Weight decreased with all treatments. For exenatide QMS, nausea (16.7-23.3%) and headache (16.7-26.7%) were the most common adverse events. No major or minor hypoglycemia occurred. All doses of exenatide QMS resulted in efficacy and tolerability profiles consistent with exenatide QW. These results combined with pharmacokinetic and pharmacodynamic modeling could inform dose selection for further development. © 2016 by the American Diabetes Association.

  11. Doses monitoring in radiology: calibration of air kerma-area product (P{sub KA}) meters; Monitoracao de doses em radiologia: a calibracao de medidores do produto kerma-area (P{sub KA})

    Energy Technology Data Exchange (ETDEWEB)

    Terini, Ricardo Andrade; Campelo, Maria Carolina de Santana; Almeida Junior, Jose Neres de, E-mail: rterini@pucsp.br [Pontificia Universidade Catolica de Sao Paulo (PUC-SP), SP (Brazil); Herdade, Silvio Bruni; Pereira, Marco Aurelio Guedes [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Instituto de Energia e Ambiente

    2013-11-15

    Materials and methods: different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm{sup 3} cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results: the lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion: the calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference. (author)

  12. Arduino based radiation survey meter

    International Nuclear Information System (INIS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee; Muzakkir, Amir

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr −1 ). Conversion factor (CF) value for conversion of CPM to μSvhr −1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr

  13. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  14. Asthma control in patients receiving inhaled corticosteroid and long-acting beta2-agonist fixed combinations. A real-life study comparing dry powder inhalers and a pressurized metered dose inhaler extrafine formulation

    Directory of Open Access Journals (Sweden)

    Nicolini Gabriele

    2011-07-01

    Full Text Available Abstract Background Although patients have more problems using metered dose inhalers, clinical comparisons suggest they provide similar control to dry powder inhalers. Using real-life situations this study was designed to evaluate asthma control in outpatients with moderate to severe persistent asthma and to compare efficacy of fixed combinations of inhaled corticosteroids (ICS and long acting beta-agonists (LABA. Methods This real-life study had a cross-sectional design. Patients using fixed combinations of ICS and LABA had their asthma control and spirometry assessed during regular visits. Results 111 patients were analyzed: 53 (47.7% received maintenance therapy of extrafine beclomethasone-formoterol (BDP/F pressurized metered dose inhaler (pMDI, 25 (22.5% fluticasone-salmeterol (FP/S dry powder inhaler (DPI, and 33 (29.7% budesonide-formoterol (BUD/F DPI. Severity of asthma at time of diagnosis, assessed by the treating physician, was comparable among groups. Asthma control was achieved by 45.9% of patients; 38.7% were partially controlled and 15.3% were uncontrolled. In the extrafine BDF/F group, asthma control total score, daytime symptom score and rescue medication use score were significantly better than those using fixed DPI combinations (5.8 ± 6.2 vs. 8.5 ± 6.8; 1.4 ± 1.8 vs. 2.3 ± 2.1; 1.8 ± 2.2 vs. 2.6 ± 2.2; p = 0.0160; p = 0.012 and p = 0.025, respectively and the mean daily ICS dose were significantly lower. Conclusions pMDI extrafine BDP/F combination demonstrated better asthma control compared to DPIs formulated with larger particles. This could be due to the improved lung deposition of the dose or less reliance on the optimal inhalation technique or both.

  15. Area monitoring of ambient dose rates in parts of South-Western Nigeria using a GPS-integrated radiation survey meter

    International Nuclear Information System (INIS)

    Okeyode, I.C.; Rabiu, J.A.; Alatise, O.O.; Makinde, V.; Akinboro, F.G.; Mustapha, A.O.; Al-Azmi, D.

    2017-01-01

    A radiation monitoring system comprising a Geiger-Muller counter connected to a smart phone via Bluetooth was used for a dose rate survey in some parts of south-western Nigeria. The smart phone has the Geographical Positioning System, which provides the navigation information and saves it along with the dose rate data. A large number of data points was obtained that shows the dose rate distribution within the region. The results show that the ambient dose rates in the region range from 60 to 520 nSv -1 and showed a bias that is attributable to the influence of geology on the ambient radiation dose in the region. The geology influence was demonstrated by superimposing the dose rate plot and the geological map of the area. The potential applications of the device in determining baseline information and in area monitoring, e.g. for lost or abandoned sources, radioactive materials stockpiles, etc., were discussed in the article, particularly against the background of Nigeria's plan to develop its nuclear power program. (authors)

  16. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation in soils

    CERN Document Server

    Yoshimura, E M; Okuno, E

    2002-01-01

    Those who work in radiation protection are faced with various quantities that were created to account for the effects of ionizing radiation in the human body. As far as the experimental point of view is concerned, each available equipment is planned to measure a distinct quantity, for a specific radiation protection application, and it is not always clear which one it is. This paper shows a series of tests, planned and applied to a portable gamma ray spectrometer, in order to assure that the monitoring low dose levels of radiation with it is reliable. The equipment is fully automated and does not allow modifications of the conversion factors from counts to ambient dose equivalent. It is therefore necessary to assure that the values provided by the equipment are correct and refer to the actual situation one expects to find in practice. The system is based on an NaI(Tl) scintillation detector, mounted with its electronics in a portable case, suitable for field measurements. It measures ambient dose equivalent r...

  17. Regional deposition of mometasone furoate nasal spray suspension in humans.

    Science.gov (United States)

    Shah, Samir A; Berger, Robert L; McDermott, John; Gupta, Pranav; Monteith, David; Connor, Alyson; Lin, Wu

    2015-01-01

    Nasal deposition studies can demonstrate whether nasal sprays treating allergic rhinitis and polyposis reach the ciliated posterior nasal cavity, where turbinate inflammation and other pathology occurs. However, quantifying nasal deposition is challenging, because in vitro tests do not correlate to human nasal deposition; gamma scintigraphy studies are thus used. For valid data, the radiolabel must distribute, as the drug, into different-sized droplets, remain associated with the drug in the formulation after administration, and not alter its deposition. Some nasal deposition studies have demonstrated this using homogenous solutions. However, most commercial nasal sprays are heterogeneous suspensions. Using mometasone furoate nasal suspension (MFS), we developed a technique to validate radiolabel deposition as a surrogate for nasal cavity drug deposition and characterized regional deposition and nasal clearance in humans. Mometasone furoate (MF) formulation was spiked with diethylene triamine pentacaetic acid. Both unlabeled and radiolabeled formulations (n = 3) were sprayed into a regionally divided nasal cast. Drug deposition was quantified by high pressure liquid chromatography within each region; radiolabel deposition was determined by gamma camera. Healthy subjects (n = 12) were dosed and imaged for six hours. Scintigraphic images were coregistered with magnetic resonance imaging scans to quantify anterior and posterior nasal cavity deposition and mucociliary clearance. The ratio of radiolabel to unlabeled drug was 1.05 in the nasal cast and regionally appeared to match, indicating that in vivo radiolabel deposition could represent drug deposition. In humans, MFS delivered 86% (9.2) of metered dose to the nasal cavity, approximately 60% (9.1) of metered dose to the posterior nasal cavity. After 15 minutes, mucociliary clearance removed 59% of the initial radiolabel in the nasal cavity, consistent with clearance rates from the ciliated posterior surface. MFS

  18. Status of neutron monitoring meters for radiation protection purpose

    International Nuclear Information System (INIS)

    Li Taosheng

    2003-01-01

    The status of and trends towards the development of neutron monitoring meters, such as dose survey meter, workplace (ambient) spectrometer and individual dosimeters, are discussed in the present paper from the perspectives of workplace and individual dose monitoring. Over the past 4 decades, both neutron dose survey meter and workplace spectrometer have declined to be more reasonable in design of their probes, with more broaden applications. With the development of electronic technology, there is a trend towards being more small-compacted and smart. Although many technical difficulties in the practical measurement, some significant progresses have be made in the development and research of these kinds of meters. (authors)

  19. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  20. Radioisotope conveyor ash meter

    International Nuclear Information System (INIS)

    Savelov, V.D.

    1994-01-01

    Radioisotope conveyor ash meter realizes persistent measuring of ashiness of coal and products of its enrichment on the belt conveyor without contact. The principle of ash meter acting is based on functional dependence of the gamma radiation flows backscattering intensity of radioisotope sources from the ash volume content in the controlled fuel. Facility consists from the ashiness transducer and the processing and control device

  1. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured t...

  2. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  3. Your Glucose Meter

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... 164KB) En Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter ...

  4. Hydrogen meter prooftesting

    International Nuclear Information System (INIS)

    McCown, J.J.; Mettler, G.W.

    1976-04-01

    Two diffusion type hydrogen meters have been tested on the Prototype Applications Loop (PAL). The ANL designed unit was used to monitor hydrogen in sodium during FFTF startup and over a wide range of hydrogen concentrations resulting from chemical additions to the sodium and cover gas. A commercially available meter was added and its performance compared with the ANL unit. Details of the test work are described

  5. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

    1996-12-31

    Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

  6. Guidance on the Use of Hand-Held Survey Meters for radiological Triage: Time-Dependent Detector Count Rates Corresponding to 50, 250, and 500 mSv Effective Dose for Adult Males and Adult Females

    International Nuclear Information System (INIS)

    Bolch, W.E.; Hurtado, J.L.; Lee, C.; Manger, Ryan P.; Hertel, Nolan; Burgett, E.; Dickerson, W.

    2012-01-01

    In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially larger numbers of individuals (100 s to 1,000 s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated by the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (G50, 50Y250, 250Y500, and 9500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances. Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be

  7. EDITORIAL: Colloidal suspensions Colloidal suspensions

    Science.gov (United States)

    Petukhov, Andrei; Kegel, Willem; van Duijneveldt, Jeroen

    2011-05-01

    Special issue in honour of Henk Lekkerkerker's 65th birthday Professor Henk N W Lekkerkerker is a world-leading authority in the field of experimental and theoretical soft condensed matter. On the occasion of his 65th birthday in the summer of 2011, this special issue celebrates his many contributions to science. Henk Lekkerkerker obtained his undergraduate degree in chemistry at the University of Utrecht (1968) and moved to Calgary where he received his PhD in 1971. He moved to Brussels as a NATO fellow at the Université Libre de Bruxelles and was appointed to an assistant professorship (1974), an associate professorship (1977) and a full professorship (1980) in physical chemistry at the Vrije Universiteit Brussel. In 1985 he returned to The Netherlands to take up a professorship at the Van 't Hoff Laboratory, where he has been ever since. He has received a series of awards during his career, including the Onsager Medal (1999) of the University of Trondheim, the Bakhuys Roozeboom Gold Medal (2003) of the Royal Dutch Academy of Arts and Sciences (KNAW), the ECIS-Rhodia European Colloid and Interface Prize (2003), and the Liquid Matter Prize of the European Physical Society (2008). He was elected a member of KNAW in 1996, was awarded an Academy Chair position in 2005, and has held several visiting lectureships. Henk's work focuses on phase transitions in soft condensed matter, and he has made seminal contributions to both the theoretical and experimental aspects of this field. Here we highlight three major themes running through his work, and a few selected publications. So-called depletion interactions may lead to phase separation in colloid-polymer mixtures, and Henk realised that the partitioning of polymer needs to be taken into account to describe the phase behaviour correctly [1]. Colloidal suspensions can be used as model fluids, with the time- and length-scales involved leading to novel opportunities, notably the direct observation of capillary waves at a

  8. Calibration of ionization chamber and GM counter survey meters, (1)

    International Nuclear Information System (INIS)

    Bingo, Kazuyoshi; Kajimoto, Yoichi; Suga, Shin-ichi

    1978-01-01

    Three types of ionization chamber survey meters and a type of GM counter survey meter were calibrated for measuring the β-ray absorbed dose rate in a working area. To estimate the β-ray absorbed dose rate, a survey meter was used without and with a filter. A reading of survey meter's indicator measured with the filter was subtracted from a reading measured without the filter, and then the absorbed dose rate was obtained by multiplying this remainder by a conversion coefficient. The conversion coefficients were roughly constant with distance more than 8 cm (ionization chamber survey meters) and with distance more than 5 cm (GM counter survey meter). The conversion coefficient was dependent on β-ray energies. In order to measure the absorbed dose rate of tissue whose epidermal thickness is 40 mg/cm 2 , the constant value, 4 (mrad/h)/(mR/h), was chosen independently of β-ray energies as the conversion coefficient of three types of ionization chamber survey meters. The conversion coefficient of the GM counter survey meter was more energy dependent than that of every type of ionization chamber survey meter. (author)

  9. Which inhaled corticosteroid and long-acting β-agonist combination is better in patients with moderate-to-severe asthma, a dry powder inhaler or a pressurized metered-dose inhaler?

    Science.gov (United States)

    Muraki, Masato; Gose, Kyuya; Hanada, Soichiro; Sawaguchi, Hirochiyo; Tohda, Yuji

    2017-11-01

    Two main types of devices are used to facilitate the administration of inhaled corticosteroid (ICS) and long-acting β-agonist (LABA) in combination, dry powder inhalers (DPIs) and pressurized metered-dose inhalers (pMDIs). There are few reports comparing the effects of the two devices, and it is unknown which should be recommended for asthma patients with given sets of characteristics. In the current study, the beneficial effects and side effects associated with DPIs and pMDIs were compared, and the question of which device should be recommended for asthma patients was investigated. A prospective, randomized, crossover, comparative study in adult outpatients with asthma was conducted using salmeterol/fluticasone propionate combination (SFC) 50 μg/250 μg, one inhalation of Adoair ® 250 Diskus ® twice daily or two inhalations of Adoair ® 125 Aerosol twice daily, for 8 weeks. Questionnaires, exhaled nitric oxide (FeNO) tests and pulmonary function tests were administered after the use of each device for 8 weeks, and the results derived from each device were compared. Sixty-eight subjects were included in the final analysis. There were no significant differences between quality-of-life scores, FeNO, spirometry test results and forced oscillation results. With regard to patient preferences, 57.4% preferred the Adoair ® Aerosol and 35.3% preferred the Adoair ® Diskus ® , as determined via the comparative evaluation questionnaire. Although DPI prescription accounts for the predominant market share of combined ICS/LABA in Japan, patients preferred a pMDI device to a DPI device. Compared to DPIs, pMDIs may be the preferential choice for patients with asthma.

  10. Digital reactivity meter

    International Nuclear Information System (INIS)

    Jiang Zongbing

    1996-02-01

    The importance and the usual methods of reactivity measurement in a nuclear reactor are presented. Emphasis is put upon the calculation principle, software and hardware components, main specifications, application, as well as the features of the digital reactivity meter. The test results of operation in various reactors shown that the meter possess the following features: high accuracy, short response time, low output noise, high resolution, wide measuring range, simple and flexible to operate, high stability and reliability. In addition, the reactivity meter can save the measuring data automatically and have a perfect capability of self-verifying. It not only meet the requirement of the reactivity measurement in nuclear power plant, but also can be applied to various types of reactors. (1 tab.)

  11. Digital reactivity meter

    International Nuclear Information System (INIS)

    Akkus, B.; Anac, H.; Alsan, S.; Erk, S.

    1991-01-01

    Nowadays, various digital methods making use of microcomputers for neutron detector signals and determining the reactivity by numerical calculations are used in reactor control systems in place of classical reactivity meters. In this work, a calculation based on the ''The Time Dependent Transport Equation'' has been developed for determining the reactivity numerically. The reactivity values have been obtained utilizing a computer-based data acquisition and control system and compared with the analog reactivity meter values as well as the values calculated from the ''Inhour Equation''

  12. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  13. Water velocity meter

    Science.gov (United States)

    Roberts, C. W.; Smith, D. L.

    1970-01-01

    Simple, inexpensive drag sphere velocity meter with a zero to 6 ft/sec range measures steady-state flow. When combined with appropriate data acquisition system, it is suited to applications where large numbers of simultaneous measurements are needed for current mapping or velocity profile determination.

  14. Carbon activity meter

    International Nuclear Information System (INIS)

    Roy, P.; Krankota, J.L.

    1975-01-01

    A carbon activity meter utilizing an electrochemical carbon cell with gaseous reference electrodes having particular application for measuring carbon activity in liquid sodium for the LMFBR project is described. The electrolyte container is electroplated with a thin gold film on the inside surface thereof, and a reference electrode consisting of CO/CO 2 gas is used. (U.S.)

  15. Knowledge of spacer device, peak flow meter and inhaler technique ...

    African Journals Online (AJOL)

    Background: Metered dose inhalers are cornerstone in effective management of bronchial asthma when correctly used. Most studies hitherto have focused on assessing patient's knowledge of inhaler technique. We sought to assess the knowledge of inhaler technique, spacer device and peak flow meter among doctors and ...

  16. Digital Receiver Phase Meter

    Science.gov (United States)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  17. Effect of budesonide/formoterol pressurized metered-dose inhaler on exacerbations versus formoterol in chronic obstructive pulmonary disease: The 6-month, randomized RISE (Revealing the Impact of Symbicort in reducing Exacerbations in COPD) study.

    Science.gov (United States)

    Ferguson, Gary T; Tashkin, Donald P; Skärby, Tor; Jorup, Carin; Sandin, Kristina; Greenwood, Michael; Pemberton, Kristine; Trudo, Frank

    2017-11-01

    Prevention of exacerbations is a primary goal for chronic obstructive pulmonary disease (COPD) therapy. This randomized, double-blind, double-dummy, parallel-group, multicenter study evaluated the effect of budesonide/formoterol pressurized metered-dose inhaler (pMDI) versus formoterol dry powder inhaler (DPI) on reducing COPD exacerbations. 1219 patients aged ≥40 years with moderate-to-very-severe COPD (per lung function) and a history of ≥1 COPD exacerbation received budesonide/formoterol pMDI 320/9 μg twice daily (BID) during a 4-week run-in. Patients were then randomized 1:1 to receive budesonide/formoterol pMDI 320/9 μg BID (n = 606) or formoterol DPI 9 μg BID (n = 613) for 26 weeks. Exacerbations were identified using predefined criteria for symptom worsening and treatment with systemic corticosteroids and/or antibiotics and/or hospitalization. The primary endpoint was annual rate of exacerbations. Budesonide/formoterol pMDI resulted in a 24% reduction in annual rate of exacerbations (0.85 vs 1.12; rate ratio: 0.76 [95% CI: 0.62, 0.92]; P = 0.006), and a significant risk reduction for time to first exacerbation (hazard ratio: 0.78 [95% CI: 0.64, 0.96]; P = 0.016) versus formoterol DPI. The most commonly reported adverse events (AEs; ≥3%) in budesonide/formoterol and formoterol groups were COPD (4.5% vs 8.6%) and nasopharyngitis (5.0% vs 5.2%). Pneumonia AEs were reported in 0.5% and 1.0% of budesonide/formoterol-treated and formoterol-treated patients, respectively. Budesonide/formoterol pMDI is an effective treatment option for reducing exacerbation rates in COPD patients with moderate-to-very-severe airflow limitation and history of exacerbations. No increase in pneumonia was observed with budesonide/formoterol; safety data were consistent with its established profile. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Hidrofluoralcano como propelente dos aerossóis pressurizados de dose medida: histórico, deposição pulmonar, farmacocinética, eficácia e segurança Hydrofluoroalkane as a propellant for pressurized metered-dose inhalers: history, pulmonary deposition, pharmacokinetics, efficacy and safety

    Directory of Open Access Journals (Sweden)

    Cássio C. Ibiapina

    2004-12-01

    Full Text Available OBJETIVO: Rever a literatura sobre o hidrofluoralcano como propelente dos inaladores de dose medida contendo medicamentos empregados na asma. FONTES DOS DADOS: O levantamento bibliográfico foi realizado em bancos de dados eletrônicos - MEDLINE, MDConsult, HighWire, Medscape e LILACS - e por pesquisa direta - referentes aos últimos 15 anos -, utilizando-se as seguintes palavras-chaves: hidrofluoralcano, asma e infância. SÍNTESE DOS DADOS: Foram selecionados 43 artigos originais abordando a questão da substituição do clorofluorcarbono pelo hidrofluoralcano. Este gás mostrou-se como uma alternativa de propelente segura, com deposição pulmonar de 50 a 60% e eficácia significativa quando comparado com placebo (p OBJECTIVE: To review the literature about hydrofluoroalkane as a propellent of pressurized metered-dose inhalers containing anti-asthma drugs. SOURCES OF DATA: Bibliographic search in electronic databases (MEDLINE, MDConsult, HighWire, Medscape and LILACS and direct search referring to the past 15 years, using the key words hydrofluoroalkane, asthma and childhood were carried out. SUMMARY OF THE FINDINGS: 43 original articles on the replacement of clorofluorcarbon by hydrofluoralkane were selected. Hydrofluoralkane showed to be a safe propellent, with pulmonary deposition ranging from 50 to 60%, and to have significant efficacy, when compared with placebo (p < 0.003 in controlled clinical trials. Most works using hydrofluoralkane included beclomethasone diproprionate. Approximate annual cost of a treatment with beclomethasone diproprionate/hydrofluoralkane was lower than with beclomethasone diproprionate/clorofluorcarbon. Some studies assessed salbutamol, fluticasone, flunisolide and the association fluticasone-salmeterol, with hydrofluoralkane as propellent in pressurized metered-dose inhalers. CONCLUSIONS: Efficacy and safety of hydrofluoralkane as propellent of bronchodilators and inhaled corticosteroids in adults was evidenced

  19. Gamma absorption meter

    International Nuclear Information System (INIS)

    Dincklage, R.D. von.

    1984-01-01

    The absorption meter consists of a radiation source, a trough for the absorbing liquid and a detector. It is characterized by the fact that there is a foil between the detector and the trough, made of a material whose binding energy of the K electrons is a little greater than the energy of the photons emitted by the radiation source. The source of radiation and foil are replaceable. (orig./HP) [de

  20. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters

    International Nuclear Information System (INIS)

    Hetland, Per O.; Friberg, Eva G.; Oevreboe, Kirsti M.; Bjerke, Hans H.

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, PKA, is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the PKA indicated by the x-ray equipment out in the clinics. Material and methods. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). Results. The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. Discussion. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the PKA calibration in hospitals. The obtained uncertainty in the PKA readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures

  1. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  2. Reassessment and suspension of the nuclear power plant design requirement of the constraint of collective dose per unit of practice. (Requirement 6 (b), Standard AR 3.1.2)

    International Nuclear Information System (INIS)

    Amado, Valeria A.; Canoba, Analia C.; Curti, Adriana R.; Biaggio, Alfredo L.

    2009-01-01

    By the middle of 2005, the Nuclear Regulatory Authority (ARN) decided to re-assess the basis of a design requirement applicable to the limitation of nuclear power reactor radioactive discharges. Such requirement, aimed at restricting the discharge of globally dispersed long-lived radionuclides, was in force in Argentina since 1979 and was expressed as a limitation of the collective dose commitment per unit of electrical energy generated. The practical result of such regulatory action was the need to retain C-14 in the Atucha II power reactor under construction as well as in future heavy water reactors to be built in the country, and, later on, to manage it as to assure its isolation from the biosphere during an appropriate period of time. For the above-mentioned reassessment, an ad hoc task group was created and an internal report was presented to the Board of Directors by the middle of 2007. Because of such report the ARN decided to suspend the application of the requirement (i.e. it is not more mandatory, even for Atucha II). The present work presents the main aspects of that report. In particular, it explains the basis of the design requirement and the most important assumptions that triggered it. The differences between the assumptions made at that time and the reality of nuclear power generation at the beginning of the 21st Century, as well as their implications in relation to the requirement are described, including the Suess effect and its impact in the total dose due to C-14. Finally, after explaining in detail the facts that made no longer reasonable to keep in force the above mentioned requirement, the work presents the conclusions that lead the ARN to the suspension of this requirement. (author) [es

  3. MULTICHANNEL DISTRIBUTION METER: A VERITABLE ...

    African Journals Online (AJOL)

    eobe

    Usually, commercial home owners preferred the installation of one or few .... communication (GSM) based solution were presented. The authors ... meters. The proposed meters in their work uses .... The most probable data entry component to ...

  4. Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems

    Energy Technology Data Exchange (ETDEWEB)

    Pope, Jason E.

    2016-07-27

    The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that we make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but

  5. Streamlining Smart Meter Data Analytics

    OpenAIRE

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, ...

  6. Smart meter incorporating UWB technology

    NARCIS (Netherlands)

    Khan, T.A.; Khan, A.B.; Babar, M.; Taj, T.A.

    2014-01-01

    Smart Meter is a key element in the evolving concept of Smart Grid, which plays an important role in interaction between the consumer and the supplier. In general, the smart meter is an intelligent digital energy meter that measures the consumption of electrical energy and provides other additional

  7. Smart metering design and applications

    CERN Document Server

    Weranga, K S K; Chandima, D P

    2013-01-01

    Taking into account the present day trends and the requirements, this Brief focuses on smart metering of electricity for next generation energy efficiency and conservation. The contents include discussions on the smart metering concepts and existing technologies and systems as well as design and implementation of smart metering schemes together with detailed examples.

  8. Net metering: zero electricity bill

    International Nuclear Information System (INIS)

    Mangi, A.; Khan, Z.

    2011-01-01

    Worldwide move towards renewable energy sources, environmental concerns and decentralization of the power sector have made net metering an attractive option for power generation at small scale. This paper discusses the net metering, economical issues of renewable sources in Pakistan, technical aspects, installation suitability according to varying terrain, existing utility rules and formulation of legislation for net metering making it economically attractive. (author)

  9. Good standards for smart meters

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Huitema, G.B.

    2012-01-01

    This paper examines what lessons can be learned from the rollout of smart meters in the Netherlands to improve the European smart meter standardization. This study is based on the case of the Dutch meter rollout which preparations started in 2005 but finally was delayed until 2011 by governmental

  10. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  11. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  12. A radon meter chamber

    International Nuclear Information System (INIS)

    Carlsson, R.

    1990-01-01

    The meter consists of a cylindrical house with two openings, at the ends, one of which is equipped with an alpha particle detector and the other covered with a metal net. The house is manufactured in an isolating material e.g. plastic, with a metallic layer applied to all internal surfaces. The metallic layer and net are kept at a positive electric potential, compared to the alpha detector, in order to attract the radon daughters to the detector and achieve a high efficiency. (L.E.)

  13. Suspension trauma; Le traumatisme de suspension

    Energy Technology Data Exchange (ETDEWEB)

    Trudel, S. [Le Centre de sante et de services sociaux du rocher Perce, Chandler, PQ (Canada)

    2010-07-01

    This presentation discussed the precautions that should be taken to avoid falls from wind turbines or transmission towers. Suspension trauma was explained by a medical doctor in terms of physiology and the body's normal circulation and the elements that disturb normal physiology when in suspension. The trauma occurs following a fall, which carries the risk of 1or more disorders, such as massive hemorrhage, high cardiac pulse, and constriction of blood vessels. Nausea, vertigo, cardiac arrhythmia and sweating occur 15 to 20 minutes following the fall. The presentation emphasized the importance of having qualified personnel at the site and wearing proper harnesses and equipment that supports the neck. figs.

  14. Solution or suspension - Does it matter for lipid based systems?

    DEFF Research Database (Denmark)

    Larsen, A T; Holm, R; Müllertz, A

    2017-01-01

    In this study, the potential of co-administering an aqueous suspension with a placebo lipid vehicle, i.e. chase dosing, was investigated in rats relative to the aqueous suspension alone or a solution of the drug in the lipid vehicle. The lipid investigated in the present study was Labrafil M2125CS...... and three evaluated poorly soluble model compounds, danazol, cinnarizine and halofantrine. For cinnarizine and danazol the oral bioavailability in rats after chase dosing or dosing the compound dissolved in Labrafil M21515CS was similar and significantly higher than for the aqueous suspension....... For halofantrine the chase dosed group had a tendency towards a low bioavailability relative to the Labrafil M2125CS solution, but still a significant higher bioavailability relative to the aqueous suspension. This could be due to factors such as a slower dissolution rate in the intestinal phase of halofantrine...

  15. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L

    1996-12-31

    Electric utilities often face situations where conventional distribution station billing meters have been removed from service. This paper presents an innovative alternative to traditional solutions to the temporary billing situation such as the use of clamp-on devices called electronic recording ammeters. It examines how Ontario Hydro is measuring current, voltage, and power factor at a distribution station to calculate kilowatts and kVAR using an easy-to-install product that communicates its live readings directly to an existing billing system. The devices used for the measurements can be easily attached to a power line with a hotstick and contain a special core which senses current flow and powers appropriate electronics, which digitizes voltage and current data and transmits it via low-power FM radio for subsequent data storage and processing. The paper includes results of field trials and outlines the advantages of using the device.

  16. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  17. Determining the ash content of coal flotation tailings using an MPOF optical ash meter

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, T; Sliwa, J

    1982-01-01

    The block layout, a description of the design and principles of operation of an automatic optical, continuous action MPOF type ash meter are presented. The difference in the optical properties of coal and rock is used in the ash meter. The identification of the ash content is conducted on the basis of the spectral characteristics of reflection of a finely dispersed aqueous coal and rock suspension.

  18. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  19. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  20. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  1. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter... conformance test requirements for the firmware upgradeability process for the Advanced Metering Infrastructure...

  2. Metering apparatus and tariffs for electricity supply

    International Nuclear Information System (INIS)

    1990-01-01

    Conference papers presented cover system economies and tariff structure with papers on pricing of electricity and new metering technologies. Other topics reviewed include metering apparatus design, electronic metering apparatus and solid phase metering technology. Meter data retrieval, bulk supply metering, test equipment and maintenance, and legal requirements and standards are discussed. (author)

  3. Rheology of organoclay suspension

    CSIR Research Space (South Africa)

    Hato, MJ

    2011-05-01

    Full Text Available The authors have studied the rheological properties of clay suspensions in silicone oil, where clay surfaces were modified with three different types of surfactants. Dynamic oscillation measurements showed a plateau-like behavior for all...

  4. Hydropneumatic suspension systems

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Wolfgang

    2011-07-01

    Hydropneumatic suspensions systems combine the excellent properties of gas springs with the favourable damping properties of hydraulic fluids. The advantages of these systems are particularly appropriate for automotive applications, such as passenger cars, trucks and agricultural equipment. In this book, Dr. Bauer provides an extensive overview of hydropneumatic suspension systems. Starting with a comparison of different types of suspension systems, the author subsequently describes the theoretical background associated with spring and damping characteristics of hydropneumatic systems and furthermore explains the design of the most important system components. Additionally he gives an overview of level control systems and various special functions. Finally the technology is illustrated by design examples and the outlook for future hydropneumatic suspensions is discussed. (orig.)

  5. Suspension Trauma / Orthostatic Intolerance

    Science.gov (United States)

    ... Suspension Trauma/Orthostatic Intolerance Safety and Health Information Bulletin SHIB 03-24-2004, updated 2011 This Safety ... the harness, the environmental conditions, and the worker's psychological state all may increase the onset and severity ...

  6. Digital reactivity meter

    International Nuclear Information System (INIS)

    Copie, M.; Valantic, B.

    1978-01-01

    Digital reactivity meters (DRM) are mostly used as measuring instruments, e.g. for calibration of control rods, and there are only a few cases of their incorporation into the control systems of the reactors. To move in this direction there is more development work needed. First of all, fast algorithms are needed for inverse kinetics equations to relieve the computer for more important tasks of reactor model solving in real time. The next problem, currently under investigation, is the incorporation of the reactor thermal-hydraulic model into the DRM so that it can be used in the power range. Such an extension of DHM allows presentation not only of the instantaneous reactivity of the system, but also the inserted reactivity can be estimated from the temperature reactivity feed-backs. One of the applications of this concept is the anomalous digital reactivity monitor (ADRN) as part of the reactor protection system. As a solution of the first problem, a fast algorithm for solving the inverse kinetics equations has been implemented in the off-line program RODCAL on CDC 1700 computer and tested for its accuracy by performing different control rod calibrations on the reactor TRIGA

  7. Gamin partable radiation meter with alarm threshold

    International Nuclear Information System (INIS)

    Payat, Rene.

    1981-10-01

    The Gamin Radiation meter is a direct reading, portable, battery-powered gamma doserate meter featuring alarm thresholds. Doserate is read on a micro-ammeter with a millirad-per-hour logarithmic scale, covering a range of 0,1 to 1000 millirads/hour. The instrument issues an audible warning signal when dose-rate level exceeds a threshold value, which can be selected. The detector tube is of the Geiger-Muller counter, energy compensated type. Because of its low battery drain, the instrument can be operated continously for 1000 hours. It is powered by four 1.5 volt alcaline batteries of the R6 type. The electronic circuitry is housed in a small lightweight case made of impact resistant plastic. Applications of the Gamin portable radiation monitor are found in health physics, safety departments, medical facilities, teaching, civil defense [fr

  8. The Mystical Suspension

    Directory of Open Access Journals (Sweden)

    Héctor Santiesteban Oliva

    2016-11-01

    Full Text Available Mistical suspension, silence, time, absolute, ontology, ineffability, aletheiaIn the mystical ecstasy there is a sensorial and intellectual suspension when contemplating the absolute, the ontological Being. Silence is not only significant: it is revealing. The greatest expression of experience inner silence . The word is insufficient when the ontological reality is revealed. Revelation or truth , the Greek concept of aletheia, takes on greater significance in that transcendental experience. It is also suspended phenomenological time and remains eternity open.

  9. 77 FR 7586 - Draft Guidance for Industry on Bioequivalence Recommendation for Nitroglycerin Metered Spray...

    Science.gov (United States)

    2012-02-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2007-D-0369... metered spray/sublingual products: An in vivo fasting study, an in vitro study of unit dose and uniformity... metered aerosol/sublingual products: An in vivo fasting study, an in vitro study of unit dose and...

  10. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing......Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social......-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...

  11. Development of a contour meter

    International Nuclear Information System (INIS)

    Andrada C, F.A.; Sanz, D.E.

    2006-01-01

    The dosimetric calculation in patients that receive radiotherapy treatment it requires the one knowledge of the geometry of some anatomical portions, which differs from a patient to another. Making reference to the specific case of mammary neoplasia, one of the measurements that is carried out on the patient is the acquisition of the contour of the breast, which is determined from a point marked on the breastbone until another point marked on the lateral of the thorax, below the armpit, with the patient located in the irradiation position. This measurement is carried out with the help of a mechanical contour meter that is a device conformed by a series of wires with a polymeric coating, which support on the breast of the patient and it reproduces its form. Then it is transported in the more careful possible form on a paper and the contour is traced with a tracer one. The geometric error associated to this procedure is of ±1 cm, which is sensitive of being reduced. The present work finds its motivation in the patient's radiological protection radiotherapy. The maximum error in dose allowed in radiotherapeutic treatments is 5%. It would be increase the precision and with it to optimize the treatment received by the patient, reducing the error in the acquisition process of the mammary contour. With this objective, a digital device is designed whose operation is based in the application of a spatial transformation on a picture of the mammary contour, which corrects the geometric distortion introduced in the process of the photographic acquisition. An algorithm that allows to obtain a front image (without distortion) of the plane of the contour was developed. A software tool especially developed carries out the processing of the digital images. The maximum geometric error detected in the validation process is 2 mm located on a small portion of the contour. (Author)

  12. Smart metering - energy data management at every meter point; Smart Metering - Energiedatenmanagement an jedem Zaehlpunkt

    Energy Technology Data Exchange (ETDEWEB)

    Keller-Giessbach, D.; Kiel, E. [LogicaCMG, Muenchen (Germany)

    2007-09-15

    The demise of monopolistic structures in the German energy market has also led to a change of perspective on metering. New requirements have to be met. Even in mass processing jobs such as meter reading it is no longer sufficient to simply read consumption data off a technically reliable meter or have customers do this themselves in preparation of billing. Currently used meters were not designed with a mind to demand management, environmental protection through energy conservation, changes in consumer behaviour or new service offers. This has been recognised in many European countries since the beginning of the present decade. The traditional task of metering is developing into a more comprehensive energy data management that takes account of the needs of customers, energy suppliers and regulatory requirements.

  13. Beyond revenue metering -- a new age for automatic meter reading

    Energy Technology Data Exchange (ETDEWEB)

    Chebra, R. J. [RJC Consulting L.L.C., PQ (Canada)

    2002-10-01

    Advanced metering, data management, and communications possibilities of automated meter reading are explored. Applications in the area of demand side management, including load reduction, peak shaving and load shifting, new tariff structures based on the 'time of use incentive/penalty' approach, and information grade metering are emphasized. Based on trends and expectations, it is predicted that AMR will continue to experience rapid growth and deployment as new services are made available to the mass market. For example, technological advances will enable the industry to make 'time of use metering ' more attractive and beneficial to residential consumers, and embedded intelligence will make it possible to achieve more holistic energy environments.

  14. Hybrid superconducting magnetic suspensions

    International Nuclear Information System (INIS)

    Tixador, P.; Hiebel, P.; Brunet, Y.; Chaud, X.; Gautier-Picard, P.

    1996-01-01

    Superconductors, especially high T c ones, are the most attractive materials to design stable and fully passive magnetic suspensions which have to control five degrees of freedom. The hybrid superconducting magnetic suspensions present high performances and a simple cooling mode. They consist of a permanent magnet bearing, stabilized by a suitable magnet-superconductor structure. Several designs are given and compared in terms of forces and stiffnesses. The design of the magnet bearing plays an important part. The superconducting magnetic bearing participates less in levitation but must provide a high stabilizing stiffness. This is achieved by the magnet configuration, a good material in term of critical current density and field cooling. A hybrid superconducting suspension for a flywheel is presented. This system consists of a magnet thrust bearing stabilized by superconductors interacting with an alternating polarity magnet structure. First tests and results are reported. Superconducting materials are magnetically melt-textured YBaCuO

  15. Magnetic Suspension Technology Workshop

    International Nuclear Information System (INIS)

    Keckler, C.R.; Groom, N.J.; Britcher, C.P.

    1993-01-01

    In order to identify the state of magnetic suspension technology in such areas as rotating systems, pointing of experiments or subsystems, payload isolation, and superconducting materials, a workshop on Magnetic Suspension Technology was held at the Langley Research Center in Hampton, Virginia, on 2-4 Feb. 1988. The workshop included five technical sessions in which a total of 24 papers were presented. The technical sessions covered the areas of pointing, isolation, and measurement, rotating systems, modeling and control, and superconductors. A list of attendees is provided. Separate abstracts have been prepared for articles from this report

  16. Automated borehole gravity meter system

    International Nuclear Information System (INIS)

    Lautzenhiser, Th.V.; Wirtz, J.D.

    1984-01-01

    An automated borehole gravity meter system for measuring gravity within a wellbore. The gravity meter includes leveling devices for leveling the borehole gravity meter, displacement devices for applying forces to a gravity sensing device within the gravity meter to bring the gravity sensing device to a predetermined or null position. Electronic sensing and control devices are provided for (i) activating the displacement devices, (ii) sensing the forces applied to the gravity sensing device, (iii) electronically converting the values of the forces into a representation of the gravity at the location in the wellbore, and (iv) outputting such representation. The system further includes electronic control devices with the capability of correcting the representation of gravity for tidal effects, as well as, calculating and outputting the formation bulk density and/or porosity

  17. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  18. Multiobjective suspension control problem

    NARCIS (Netherlands)

    Jager, de A.G.

    1995-01-01

    The paper describes a (controller) design problem in the field of suspension systems for transport vehicles. A ten degrees-of-freedom model for a tractor-semitrailer vehicle is presented, using parameters derived from a real vehicle, which should be used for design and verification purposes. Road

  19. Calibration for radiation protection survey meter SSM1

    International Nuclear Information System (INIS)

    Jin Hua.

    1992-03-01

    The calibration functions for the Radiation Protection Survey Meter SSM1 built-in Geiger Mueller measuring tubes of the type ZP 1201 (low dose rate tube) and ZP 1313 (high dose rate tube) are given in the present study. Six dose rate points are proposed as the calibration points of covering the range from 500 nSv/h up to 5 Sv/h. The difference between the true dose rate and the values calculated with the method in this paper for No. 382 SSM1 is less than ±2%. (author)

  20. Chlorophyll meter reading and total nitrogen content applied as ...

    African Journals Online (AJOL)

    The present study was aimed to assess the relationship between the reading of the chlorophyll meter and the total nitrogen (N) content in the leaf in different parts of the crambe plant, depending on the doses of nitrogen applied to the canopy. Randomized block design in a split plot experimental design was used. The plots ...

  1. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  2. Low Cost Digital Vibration Meter.

    Science.gov (United States)

    Payne, W Vance; Geist, Jon

    2007-01-01

    This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibration of the device in the plane perpendicular to the cantilever beam causes it to bend, which produces a measurable change in the resistance of a piezoresistor. These changes in resistance along with a unique signal-processing scheme are used to determine an approximation to the RMS acceleration sensed by the device.

  3. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    suppliers, but they can also play a big role in the control of the Microgrid since the recorded power and energy profiles can be integrated in energy management systems (EMS). In addition, basic power quality (PQ) disturbance can de detected and reported by some advanced metering systems. Thus, this paper...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  4. Metering in the gas supply sector; Metering in der Gasversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Wernekinck, U. [RWE Westfalen-Weser-Ems, Recklinghausen (Germany)

    2007-10-15

    The new conditions of competition in the gas supply sector have strongly increased the requirements on gas grid operators. Mainly an exact gas metering and -accouting will become more and more important. The systems and procedures are presented in detail in this contribution. (GL)

  5. Microprocessor controlled digital period meter

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1980-01-01

    A microprocessor controlled digital period meter has been developed and tested operationally on a reactor at Argonne National Laboratory. The principle of operation is the mathematical relationship between asymptotic periods and pulse counting circuitry. This relationship is used to calculate and display the reactor periods over a range of /plus or minus/1 second to /plus or minus/999 seconds. The time interval required to update each measurement automatically varies from 8 seconds at the lowest counting rates to 2 seconds at higher counting rates. The paper will describe hardware and software design details and show the advantages of this type of Period Meter over the conventional circuits. 1 ref

  6. Dosis elevada en el dosímetro personal de una auxiliar de enfermería en Electrofisiología A high dose in the personal dosage meter of nursing assistant in Electrophysiology field

    Directory of Open Access Journals (Sweden)

    Raquel Barquero Sanz

    2012-03-01

    Full Text Available En una sala de Electrofisiología del Servicio de Cardiología en donde se efectúan procedimientos guiados con rayos X de ablación con radiofrecuencia y de implantes de desfibrilador biventricular, se registraron dosis mensuales anormalmente elevadas en el dosímetro personal de solapa de una auxiliar de enfermería que trabaja en la misma, con valores de dosis equivalente personal, Hp(10, de 125 mSv y de dosis equivalente personal superficial, Hp(0.07 de 128.1 mSv. Ante la ansiedad producida en la trabajadora al conocer las lecturas de su dosímetro, y dado que no se dispone de precedentes investigados en la instalación, se ha realizado un estudio para dilucidar si la dosis registrada ha podido ser recibida por la trabajadora o si solo ha sido recibida por el dosímetro. Se hacen medidas con un monitor ambiental en condiciones simuladas de los procedimientos, para estimar las dosis reales que pueda recibir el personal de la sala. Se comparan estos valores con los del rendimiento del equipo de RX en haz directo medidos durante la revisión anual de control de calidad del mismo, concluyéndose que ha sido el dosímetro, y no la trabajadora, el que se ha expuesto a radiación directa, siendo la situación más probable la de que dicho dosímetro cayó sobre el tubo de RX, normalmente orientado hacia el techo, un tiempo del orden de 1 minuto. Paralelamente a estas estimaciones dosimétricas, el Servicio de Prevención de Riesgos Laborales realizó la vigilancia de la salud, concluyendo que la trabajadora no tenía ningún indicio de haber recibido dosis de la magnitud registrada por su dosímetro.In a room of electrophysiology from the cardiology service where procedures are made guided with X-Rays of ablation with radiofrequency and from implants ventricular defibrillation; there were registered monthly doses usually high in the same personal dosimeter flap of a nursing assistant who works there with values of equivalent personal doses, Hp (10

  7. Arrival metering fuel consumption analysis

    Science.gov (United States)

    2011-01-01

    Arrival metering is a method of time-based traffic management that is used by the Federal Aviation Administration to plan and manage streams of arrival traffic during periods of : high demand at busy airports. The Traffic Management Advisor is an aut...

  8. The Thirty-Meter Telescope

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The Thirty-Meter Telescope international observatory will enable transformational observations over the full cosmic timeline all the way from the first luminous objects in the Universe to the planets and moons of our own solar system. To realize its full scientific potential, TMT will be equipped with a powerful ...

  9. Rate meter design and construction

    International Nuclear Information System (INIS)

    Peon Aguirre, R.; Fonseca Araujo, W.H.

    1989-01-01

    An electric diagram is proposed to build a geiger detector Rate Meter, to count gamma radiation and X ray. This idea was made up with the prototype construction which has a five scales analogue display (100, 300, 1000, 3000 and 10000 c/s). (Author)

  10. Particle interactions in concentrated suspensions

    International Nuclear Information System (INIS)

    Mondy, L.A.; Graham, A.L.; Abbott, J.R.; Brenner, H.

    1993-01-01

    An overview is presented of research that focuses on slow flows of suspensions in which colloidal and inertial effects are negligibly small. The authors describe nuclear magnetic resonance imaging experiments to quantitatively measure particle migration occurring in concentrated suspensions undergoing a flow with a nonuniform shear rate. These experiments address the issue of how the flow field affects the microstructure of suspensions. In order to understand the local viscosity in a suspension with such a flow-induced, spatially varying concentration, one must know how the viscosity of a homogeneous suspension depends on such variables as solids concentration and particle orientation. The authors suggest the technique of falling ball viscometry, using small balls, as a method to determine the effective viscosity of a suspension without affecting the original microstructure significantly. They also describe data from experiments in which the detailed fluctuations of a falling ball's velocity indicate the noncontinuum nature of the suspension and may lead to more insights into the effects of suspension microstructure on macroscopic properties. Finally, they briefly describe other experiments that can be performed in quiescent suspensions (in contrast to the use of conventional shear rotational viscometers) in order to learn more about boundary effects in concentrated suspensions

  11. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  12. REM meter for pulsed sources of neutrons

    International Nuclear Information System (INIS)

    Thorngate, J.E.; Hunt, G.F.; Rueppel, D.W.

    1980-01-01

    A rem meter was constructed specifically for measuring neutrons produced by fusion experiments for which the source pulses last 10 ms or longer. The detector is a 6 Li glass scintillator, 25.4 mm in diameter and 3.2 mm thick, surrounded by 11.5 cm of polyethylene. This detector has a sensitivity of 8.5 x 10 4 counts/mrem. The signals from this fast scintillator are shaped using a shorted delay line to produce pulses that are only 10 ns long so that dose equivalent rates up to 12 mrem/s can be measured with less than a 1% counting loss. The associated electronic circuits store detector counts only when the count rate exceeds a preset level. When the count rate returns to background, a conversion from counts to dose equivalent is made and the results are displayed. As a means of recording the number of source pulses that have occurred, a second display shows how many times the preset count rate has been exceeded. Accumulation of detector counts and readouts can also be controlled manually. The unit will display the integrated dose equilavent up to 200 mrem in 0.01 mrem steps. A pulse-height discriminator rejects gamma-ray interactions below 1 MeV, and the detector size limits the response above that energy. The instrument can be operated from an ac line or will run on rechargeable batteries for up to 12 hours

  13. Administrative license suspension: Does length of suspension matter?

    Science.gov (United States)

    Fell, James C; Scherer, Michael

    2017-08-18

    Administrative license revocation (ALR) laws, which provide that the license of a driver with a blood alcohol concentration at or over the illegal limit is subject to an immediate suspension by the state department of motor vehicles, are an example of a traffic law in which the sanction rapidly follows the offense. The power of ALR laws has been attributed to how swiftly the sanction is applied, but does the length of suspension matter? Our objectives were to (a) determine the relationship of the ALR suspension length to the prevalence of drinking drivers relative to sober drivers in fatal crashes and (b) estimate the extent to which the relationship is associated to the general deterrent effect compared to the specific deterrent effect of the law. Data comparing the impact of ALR law implementation and ALR law suspension periods were analyzed using structural equation modeling techniques on the ratio of drinking drivers to nondrinking drivers in fatal crashes from the Fatality Analysis Reporting System (FARS). States with an ALR law with a short suspension period (1-30 days) had a significantly lower drinking driver ratio than states with no ALR law. States with a suspension period of 91-180 days had significantly lower ratios than states with shorter suspension periods, while the three states with suspension lengths of 181 days or longer had significantly lower ratios than states with shorter suspension periods. The implementation of any ALR law was associated with a 13.1% decrease in the drinking/nondrinking driver fatal crash ratio but only a 1.8% decrease in the intoxicated/nonintoxicated fatal crash ratio. The ALR laws and suspension lengths had a significant general deterrent effect, but no specific deterrent effect. States might want to keep (or adopt) ALR laws for their general deterrent effects and pursue alternatives for specific deterrent effects. States with short ALR suspension periods should consider lengthening them to 91 days or longer.

  14. Squid based beam current meter

    International Nuclear Information System (INIS)

    Kuchnir, M.

    1983-01-01

    A SQUID based beam current meter has the capability of measuring the current of a beam with as little as 30 x 155 antiprotons (with a signal to noise ratio of 2). If low noise dc current is used to cancel most of the beam or an up-down counter is used to count auto-resets this sensitivity will be available at any time in the acumulation process. This current meter will therefore be a unique diagnostic tool for optimizing the performance of several Tev I components. Besides requiring liquid helium it seems that its only drawback is not to follow with the above sensitivity a sudden beam change larger than 16 μA, something that could be done using a second one in a less sensitive configuration

  15. Federal Building Metering Guidance (per 42 U.S.C. 8253(e), Metering of Energy Use)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    Guidance defines which federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans to the U.S. Department of Energy.

  16. Elimination of acute muelogenous leukemic cells from marrow and tumor suspensions in the rat with 4-hydroperoxycyclophosphamide

    International Nuclear Information System (INIS)

    Sharkis, S.J.; Santos, G.W.; Colvin, M.

    1980-01-01

    Cell suspensions of normal rat marrow mixed with rat acute myelogenous leukemic cells were prepared and incubated in vitro with graded doses of 4-hydroperoxycyclophosphamide (4HC). The cell suspensions were injected into rats prepared with a lethal dose of total body irradiation. Animals injected with these cells survived fatal irradiation induced aplasia. In a dose related manner 4HC was able to purge tumor cells from the cell mixtures. Thus, animals given cell suspensions incubated with the lower doses of 4HC showed prolonged survived before death from leukemia and animals given cell suspensions incubated with higher doses of 4HC survival lethal irradiation without the subsequent appearance of leukemia. These studies clearly establish that tumor cells may be eliminated from normal marrow suspensions without completely destroying the pluripotent stem cells

  17. Inalador dosimetrado com espaçador artesanal versus nebulizador no tratamento da crise de sibilância na criança Metered-dose inhaler with home-made spacer versus nebulizers to treat moderate wheezing attacks in children

    Directory of Open Access Journals (Sweden)

    Liana Consuelo Santana Vilarinho

    2003-10-01

    oximetria. A comparação dos parâmetros clínicos e de saturação de oxigênio, entre os grupos, não mostrou diferença significativa após as doses de salbutamol, havendo equivalência clínica entre doses diferentes (três vezes menor no grupo IDE, em relação ao grupo NEB; os tempos de preparo e administração da medicação e o custo do tratamento foram significativamente menores no grupo IDE. O grau de satisfação das famílias foi semelhante nos dois grupos. CONCLUSÃO: O inalador dosimetrado com espaçador artesanal pode ser utilizado na admini stração de salbutamol a crianças em crise de sibilância, com algumas vantagens em relação ao nebulizador.OBJECTIVE: To compare the effectiveness of salbutamol administration by metered-dose inhaler with a home-made spacer versus jet nebulizer in children with moderate wheezing attacks. MATERIAL AND METHODS: A randomized, single-blinded trial was performed with a convenience sample of children presenting wheezing. The children were enrolled in an emergency room and randomly assigned to one of two treatment groups: home-made spacer group or nebulizer group. Clinical scores and oxygen saturation were recorded at baseline and 15 minutes after salbutamol administration. Treatment with salbutamol (100 µg/3 kg in the spacer group, and 250 µg/3 kg in the nebulizer group was repeated at 20-minute intervals, until the child was considered to have improved significantly, with no need of any further dose, or until three doses were delivered. Treatment cost, time spent to prepare and deliver the drug, and level of parental satisfaction with the treatment were recorded. RESULTS: Fifty-four children with age between 22 days and 11.7 years were enrolled - 27 in each group. Baseline and demographic characteristics were similar for both groups. The spacer was as effective as the nebulizer in terms of clinical score and oxygen saturation. The different doses (100 µg/3 kg with the spacer, and 250 µg/3 kg with the nebulizer were

  18. Calibration of PKA meters against ion chambers of two geometries

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Pereira, Marco A.G.; Herdade, Silvio B.

    2011-01-01

    Kerma-area product (KAP or PKA) is a quantity that is independent of the distance to the X-ray tube focal spot and that can be used in radiological exams to assess the effective dose in patients. Clinical KAP meters are generally fixed in tube output and they are usually calibrated on-site by measuring the air kerma with an ion chamber and by evaluating the irradiated area by means of a radiographic image. Recently, a device was marketed (PDC, Patient Dose Calibrator, Radcal Co.), which was designed for calibrating clinical KAP meters with traceability to a standard laboratory. This paper presents a metrological evaluation of two methods that can be used in standard laboratories for the calibration of this device, namely, against a reference 30 cc ionization chamber or a reference parallel plates monitor chamber. Lower energy dependence was also obtained when the PDC calibration was made with the monitor chamber. Results are also shown of applying the PDC in hospital environment to the cross calibration of a clinical KAP meter from a radiology equipment. Results confirm lower energy dependence of the PDC relatively to the tested clinical meter. (author)

  19. Evaluating Suspension Formulations of Theophylline Cocrystals With Artificial Sweeteners.

    Science.gov (United States)

    Aitipamula, Srinivasulu; Wong, Annie B H; Kanaujia, Parijat

    2018-02-01

    Pharmaceutical cocrystals have garnered significant interest as potential solids to address issues associated with formulation development of drug substances. However, studies concerning the understanding of formulation behavior of cocrystals are still at the nascent stage. We present results of our attempts to evaluate suspension formulations of cocrystals of an antiasthmatic drug, theophylline, with 2 artificial sweeteners. Stability, solubility, drug release, and taste of the suspension formulations were evaluated. Suspension that contained cocrystal with acesulfame showed higher drug release rate, while a cocrystal with saccharin showed a significant reduction in drug release rate. The cocrystal with saccharin was found stable in suspension for over 9 weeks at accelerated test condition; in contrast, the cocrystal with acesulfame was found unstable. Taste analysis using an electronic taste-sensing system revealed improved sweetness of the suspension formulations with cocrystals. Theophylline has a narrow therapeutic index with a short half-life which necessitates frequent dosing. This adversely impacts patient compliance and enhances risk of gastrointestinal and cardiovascular adverse effects. The greater thermodynamic stability, sweetness, and sustained drug release of the suspension formulation of theophylline-saccharin could offer an alternative solution to the short half-life of theophylline and make it a promising formulation for treating asthmatic pediatric and geriatric patients. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  20. Cross-cultural differences in meter perception.

    Science.gov (United States)

    Kalender, Beste; Trehub, Sandra E; Schellenberg, E Glenn

    2013-03-01

    We examined the influence of incidental exposure to varied metrical patterns from different musical cultures on the perception of complex metrical structures from an unfamiliar musical culture. Adults who were familiar with Western music only (i.e., simple meters) and those who also had limited familiarity with non-Western music were tested on their perception of metrical organization in unfamiliar (Turkish) music with simple and complex meters. Adults who were familiar with Western music detected meter-violating changes in Turkish music with simple meter but not in Turkish music with complex meter. Adults with some exposure to non-Western music that was unmetered or metrically complex detected meter-violating changes in Turkish music with both simple and complex meters, but they performed better on patterns with a simple meter. The implication is that familiarity with varied metrical structures, including those with a non-isochronous tactus, enhances sensitivity to the metrical organization of unfamiliar music.

  1. Net metering in British Columbia : white paper

    International Nuclear Information System (INIS)

    Berry, T.

    2003-01-01

    Net metering was described as being the reverse registration of an electricity customer's revenue meter when interconnected with a utility's grid. It is a provincial policy designed to encourage small-distributed renewable power generation such as micro-hydro, solar energy, fuel cells, and larger-scale wind energy. It was noted that interconnection standards for small generation is an important issue that must be addressed. The British Columbia Utilities Commission has asked BC Hydro to prepare a report on the merits of net metering in order to support consultations on a potential net metering tariff application by the utility. This report provides information on net metering with reference to experience in other jurisdictions with net metering, and the possible costs and benefits associated with net metering from both a utility and consumer perspective. Some of the barriers and policy considerations for successful implementation of net metering were also discussed. refs., tabs., figs

  2. Versatile operation meter for nuclear information

    International Nuclear Information System (INIS)

    Huang Yong; Xiao Yabin; Wang Shuyuan; Shu Jingfang; Di Shaoliang; Wu Hongbin

    1995-01-01

    This paper states a low-cost, small-volume, multi-function, reproducible and new model intelligent nuclear electronic meter. It's hardware and Software were detailed and the 137 Cs spectrum with this meter was presented

  3. Hardware Design of a Smart Meter

    OpenAIRE

    Ganiyu A. Ajenikoko; Anthony A. Olaomi

    2014-01-01

    Smart meters are electronic measurement devices used by utilities to communicate information for billing customers and operating their electric systems. This paper presents the hardware design of a smart meter. Sensing and circuit protection circuits are included in the design of the smart meter in which resistors are naturally a fundamental part of the electronic design. Smart meters provides a route for energy savings, real-time pricing, automated data collection and elimina...

  4. Intelligent Metering for Urban Water: A Review

    OpenAIRE

    Rodney Stewart; Stuart White; Candice Moy; Ariane Liu; Pierre Mukheibir; Damien Giurco; Thomas Boyle

    2013-01-01

    This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering) has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been ...

  5. Development of a CONTOUR-METER

    International Nuclear Information System (INIS)

    Andrada Contardi, F.A.

    2004-01-01

    Dose calculation in patients undergoing radiotherapy treatments requires the knowledge of their anatomical geometry.Making reference to the specific case of breast cancer, one of the measurement that are made on the patients is the acquisition of the breast's contour, determined in an axial plane from a point marked on the breastbone until another point marked on the thorax side under the armpit.This measurement is normally made with a mechanic contour-meter: a device formed by a series of plastic-covered wires designed to be applied on the patient's skin copying the breast contour after it deformation.The geometrical error associated with this procedure is ± 1 cm. The precision of the dose calculation could be increased acquiring a breast contour more accurate.This objective was achieved developing a method based on breast images from a digital camera.The algorithms to obtain an axial-plane image of the contour from digital photographs taken from arbitrary positions were developed.A geometric transformation is applied to the photograph to correct for perspective distortions, obtaining a frontal - undistorted image (axial-plane image).A software tool to make all the image processing was developed under MatLab.The maximum geometrical error detected during the validation of the process was 2 mm [es

  6. Analysis of nano-meter structure in Ti implanted polymers

    International Nuclear Information System (INIS)

    Zhou Gu; Wu Yuguang; Zhang Tonghe; Zhao Xinrong

    2001-01-01

    Polyethylene terephthalate (PET) is modified with Ti ion implantation to a dose of 1x10 17 to 2 x 10 17 cm -2 by using a metal vapor vacuum arc(MEVVA)source. Nano-meter structures in the implanted sample are observed by means of transmission electron microscope (TEM). The influence of ion dose on the structure is indicated. The results show that dense nano-meter phases are dispersed uniformly in the implanted layer. TEM cross section indicates that there is a three-layer structure in the implanted PET. It is found that a metallurgical surface is formed. Therefore the hardness, wear resistance and conductive properties of PET are improved after metal ion implantation. The mechanism of electrical conduction will be discussed

  7. Magnetorheological suspension electromagnetic brake

    International Nuclear Information System (INIS)

    Bica, Ioan

    2004-01-01

    The magnetorheological suspension (MRS) brake is of the monoblock type. The main part of the electromagnetic brake is an electromagnet, between whose poles two MRS disks are placed. For distances between disks of 0.65x10 -3 m±10%, revolutions of the electric motor, coupled to the electromagnetic brake, ranging between 200 and 1600 rev/min and braking powers of up to 85 W, there are no differences in revolutions between the disks of the electromagnetic brake. For fixed revolutions of the electric motor, the revolution of the parallel disk can be modified continuously by means of the intensity of the magnetic field. In all cases, the quantity of MRS is of 0.35x10 -3 kg

  8. Smart Metering. Technological, economic and legal aspects. 2. ed.; Smart Metering. Technologische, wirtschaftliche und juristische Aspekte des Smart Metering

    Energy Technology Data Exchange (ETDEWEB)

    Koehler-Schute, Christiana (ed.)

    2010-07-01

    Smart metering comprises more than just meter technology, and the use of information and communication technologies is indispensable. Processes, roles and business models must be reconsidered as further challenges arise in the context of smart metering. For one, there is the operator of the metering points. Secondly, there is the end user who is in the role of an active market partner. Further, there is smart metering as a basic technology, e.g. for smart grids and smart homes. In spite of the need for action, many utilities are reluctant to introduce smart metering. Reasons for this are the cost, a lack of defined standards, and an unclear legal situation. On the other hand, smart metering offers potential for grids and distribution that should be made use of. The authors discuss all aspects of the subject. The point out the chances and limitations of smart metering and present their own experience. [German] Smart Metering geht weit ueber die Zaehlertechnologie hinaus und der Einsatz von Informations- und Kommunikationstechnologien ist unabdingbar. Damit einhergehend muessen Prozesse, Rollen und auch Geschaeftsmodelle neu durchdacht werden. Denn weitere Herausforderungen stehen im direkten Zusammenhang mit Smart Metering. Das ist zum einen die Rolle des Messstellenbetreibers / Messdienstleisters. Das ist zum anderen der Endnutzer, dem die Rolle des aktiven Marktpartners zugedacht wird. Das ist des Weiteren das Smart Metering als Basistechnologie beispielsweise fuer Smart Grid und Smart Home. Trotz des Handlungsdrucks stehen viele Unternehmen der Energiewirtschaft dem Smart Metering zurueckhaltend gegenueber. Drei gewichtige Gruende werden ins Feld gefuehrt: die Kostenfrage, nicht definierte Standards und die in vielen Bereichen ungeklaerte Gesetzeslage. Demgegenueber bietet das Smart Metering Potenziale fuer Netz und Vertrieb, die es zu nutzen gilt. Die Autoren setzen sich in ihren Beitraegen mit diesen Themen auseinander, zeigen Chancen, aber auch Grenzen des

  9. Fundamental principles of rotary displacement meters

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J. [Schlumberger Industries, Owenton, KY (United States)

    1995-12-01

    The gas meter exists to continually and accurately measure the volume of gas supplied over the complete flow range of the load. In effect the gas meter serves as the {open_quotes}cash register{close_quotes} of the gas industry; its accurate and dependable performance ensures fair dealings for both the supplier and the user. An investment both in and of itself, the gas meter should be chosen as a function of its usefullness both over the short term and the long term. Thus in addition to initial cost, one must take into account various associated factors, costs and benefits, including the following: Design Characteristics Application, suitability, Meter features and options, Operation constraints, Installation, Service and maintenance, Repair and replacement, Life expectancy, Compatibility with complimentary products, Correcting devices, Remote reading capabilities, Data generation and gathering, Upgradeabilty. This paper will look at one positive displacement meter, the Rotary meter, and address the fundamentals principals of the technology as well as looking at some of the benefits derived from its application. Rotary positive displacement meters were introduced at the end of last century. Used primarily for metering transmission sized loads, the meters` measuring capabilities have extended to cover nearly all areas of distribution with exception of domestic applications. Rotary meters are available in rated capacities from 800 cfh to 102,000 cfh and operating pressures from 175 PSIG to 1440 PSIG. The use of rotary meters on load ranges in the 800 to 10,000 cfh category has increased and is replacing the use of diaphragm meters because of the smaller relative size of rotaries, and improvements in rangeabilities in the last few years. Turbine meters are usually the meter of choice on loads over 16,000 cfh unless a meter with high rangeability is required because of varying load characteristics, in which case a large foot mounted rotary might still be selected.

  10. Smart meter status report from Toronto

    International Nuclear Information System (INIS)

    O'Brien, D.

    2006-01-01

    An update of Toronto Hydro's smart metering program was presented. Electricity demand is expected to keep increasing, and there is presently insufficient generation to match supply needs in Ontario. The smart metering program was introduced to aid in the Ontario government's energy conservation strategy, as well as to address peak supply problems that have led to power outages. It is expected that the smart metering program will reduce provincial peak supply by 5 per cent, as the meters support both time-of-use rates and critical peak pricing. Over 800,000 smart meters will be supplied to customers by 2007, and all 4.3 million homes in Toronto will have a smart meter by 2010. In order to meet targets for 2010, the utility will continue to install more 15,000 meters each month for the next 4 years. While the Ontario government has planned and coordinated the rollout and developed smart metering specifications and standards, Toronto Hydro is responsible for the purchase, installation, operation and maintenance of the meters. Advance testing of each meter is needed to ensure billing accuracy, and customer education on meter use is also. The complexity of the metering program has led the utility to establish a rigid project management process. Customer education pilot program are currently being conducted. Experience gained during the earlier phases of the program have enabled the utility to select appropriate metering systems based on density, topography and physical conditions. Project expenditures have been within budget due to improved project estimating and planning. The metering program has been conducted in tandem with the utility's peakSAVER program, a residential and small commercial load control program that has been successful in reducing summer peak demand by cycling air conditioners without causing discomfort. It was concluded that the utility will continue with its mass deployment of smart meters, and is currently preparing its call center to handled

  11. Optimization of a neutron ambient dose equivalent rate meter

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Fieg, G.; Piesch, E.; Klett, A.; Maushart, R.

    1994-01-01

    Co-operating in a technology transfer project, the Karlsruhe Nuclear Research Center and EG and G Berthold have developed a neutron equivalent doserate probe with high sensitivity and an energy dependent detection efficiency in accordance with the ICRP60 requirements. The special features of this probe were realized, on the one hand, by optimizing the moderator and absorber geometry through simulation calculations with the neutron transport code MCNP, and, on the other hand, by using a newly designed 3 He-methane proportional counter tube. The measurements were not yet completed when this paper went to press, however, it is to be expected that the response sensitivity will be more than 3 counts/nSv. (orig.) [de

  12. Development of slow neutron dose meter by track counting

    International Nuclear Information System (INIS)

    Nozaki, Tetsuya; Takeuchi, Hiroshi; Hasnel, S.; Honda, Teruyuki; Harasawa, Susumu.

    1993-01-01

    Prototypes of a plate type and two types of semispherical dosemeter were manufactured and their performances were tested. Polyallyl diglycol carbonate (PADC) was employed as neutron detector and covered with natural LiF and 6 Li-enriched LiF ceramics. They were irradiated in the TRIGA II Reactor of the Rikkyo University, and the sensitivity characteristics for incident angles and neutron energies were analyzed. It is concluded that it may be possible to manufacture small sized neutron dosemeter of flat response to wide energy range from thermal neutrons to epithermal neutrons with sufficient sensitivity for personal monitoring, using LiF ceramic as neutron filters and neutron converters. However the following issues are to be solved: the optimization of thickness of the LiF filter, the effects of albedo of the human body, and the applicability to the intermediate neutrons. (A.Y.)

  13. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  14. The 59 meter dash - automatic rapid meter reading in Ronneby

    Energy Technology Data Exchange (ETDEWEB)

    Ottosson, Hans [Enersearch (Sweden); Selander, Lars [Linkoeping Univ. (Sweden); Bergstroem, Ulrika [Sydkraft (Sweden)

    1999-02-01

    As a result of deregulation of the telecommunications and energy markets, the utilities in Sweden see opportunities to use power lines for additional profitable applications such as transmission of data; the technology is called Power Line Telecommunications (PLT). The potential advantages are said to be 'massive'. The potential applications include remote security, automatic meter reading, load management and 'smart' home automation. A small scale feasibility study has been carried out in Ronneby in Sweden where it was shown that load management and efficiency improvements can reduce the costs of supplying the town with heat and electricity by about 3%. The Ronneby trial is described in detail. Since Scandinavia makes use of weather-dependent renewables for much of its power generation, load management is an attractive potential application of PLT. (UK)

  15. Development of a calibration methodology and tests of kerma area product meters

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida

    2013-01-01

    The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient's skin doesn't exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter. (author)

  16. Too cheap to meter what?

    International Nuclear Information System (INIS)

    Wedekind, Lothar

    2004-01-01

    Full text: 50 years ago, at 17:30 hours, 26 June 1954, in the town of Obninsk, near Moscow, the first nuclear power plant sent electricity to residences and businesses. Atomic energy had crossed the divide from military uses to peaceful ones, demonstrating the potential to fuel civilian electric power plants. The milestone is being marked this year at an IAEA international nuclear power conference in Obninsk. Past experience will be reviewed, but the focus is on meeting future challenges. Though it has come a long way in 50 years, nuclear energy today finds itself in a struggle of the fittest to carve a niche over the next fifty - in the marketplace and in the public eye. Cliches and sound bites tell part of the nuclear story. Visionary talk by nuclear proponents in 1954 was about future energy sources that would be 'too cheap to meter', a phrase critics pounced upon. Today in 2004 the 'too cheap to meter' phrase occasionally haunts the atom, but pops up more often than not in promotional ads for anything from wind power to web sites. Talk of nuclear energy now is of a 'renaissance' and 'second wind.' New nuclear plants are most attractive where energy demand is growing and resources are scarce, and where energy security, air pollution and greenhouse gases are priorities, IAEA Director General Mohamed ElBaradei points out. In cities, towns, and villages, reality is different, or too much the same, depending how you see and live it. Cheap or not, nuclear energy today supplies one-sixth of the world's electricity in some 30 countries. Still, it does not produce enough power. Neither does any other energy source. More than 1.5 billion people have no electricity to meter whatsoever - not from renewables, solar, nuclear, biomass, wind, coal, oil, gas, firewood, or hydrogen, the publicized promise of tomorrow. So what will it take? Maybe bigger blackouts or hotter days than the world has seen. Certainly needed are more attention, action, and money. In dollar terms

  17. A glucose meter evaluation co-designed with both health professional and consumer input.

    Science.gov (United States)

    Thompson, Harmony; Chan, Huan; Logan, Florence J; Heenan, Helen F; Taylor, Lynne; Murray, Chris; Florkowski, Christopher M; Frampton, Christopher M A; Lunt, Helen

    2013-11-22

    Health consumer's input into assessment of medical device safety is traditionally given either as part of study outcome (trial participants) or during post marketing surveillance. Direct consumer input into the methodological design of device assessment is less common. We discuss the difference in requirements for assessment of a measuring device from the consumer and clinician perspectives, using the example of hand held glucose meters. Around 80,000 New Zealanders with diabetes recently changed their glucose meter system, to enable ongoing access to PHARMAC subsidised meters and strips. Consumers were most interested in a direct comparison of their 'old' meter system (Accu-Chek Performa) with their 'new' meter system (CareSens brand, including the CareSens N POP), rather than comparisons against a laboratory standard. This direct comparison of meter/strip systems showed that the CareSens N POP meter read around 0.6 mmol/L higher than the Performa system. Whilst this difference is unlikely to result in major errors in clinical decision making such as major insulin dosing errors, this information is nevertheless of interest to consumers who switched meters so that they could maintain access to PHARMAC subsidised meters and strips. We recommend that when practical, the consumer perspective be incorporated into study design related to medical device assessment.

  18. Controlling active cabin suspensions in commercial vehicles

    NARCIS (Netherlands)

    Evers, W.J.E.; Besselink, I.J.M.; Teerhuis, A.P.; Knaap, van der A.C.M.; Nijmeijer, H.

    2009-01-01

    The field of automotive suspensions is changing. Semi-active and active suspensions are starting to become viable options for vehicle designers. Suspension design for commercial vehicles is especially interesting given its potential. An active cabin suspension for a heavy-duty truck is considered,

  19. ATD-2 Surface Scheduling and Metering Concept

    Science.gov (United States)

    Coppenbarger, Richard A.; Jung, Yoon Chul; Capps, Richard Alan; Engelland, Shawn A.

    2017-01-01

    This presentation describes the concept of ATD-2 tactical surface scheduling and metering. The concept is composed of several elements, including data exchange and integration; surface modeling; surface scheduling; and surface metering. The presentation explains each of the elements. Surface metering is implemented to balance demand and capacity• When surface metering is on, target times from surface scheduler areconverted to advisories for throttling demand• Through the scheduling process, flights with CTOTs will not get addedmetering delay (avoids potential for ‘double delay’)• Carriers can designate certain flights as exempt from metering holds• Demand throttle in Phase 1 at CLT is through advisories sent to rampcontrollers for pushback instructions to the flight deck– Push now– Hold for an advised period of time (in minutes)• Principles of surface metering can be more generally applied to otherairports in the NAS to throttle demand via spot-release times (TMATs Strong focus on optimal use of airport resources• Flexibility enables stakeholders to vary the amount of delay theywould like transferred to gate• Addresses practical aspects of executing surface metering in aturbulent real world environment• Algorithms designed for both short term demand/capacityimbalances (banks) or sustained metering situations• Leverage automation to enable surface metering capability withoutrequiring additional positions• Represents first step in Tactical/Strategic fusion• Provides longer look-ahead calculations to enable analysis ofstrategic surface metering potential usage

  20. "Point de suspension"

    CERN Multimedia

    2004-01-01

    CERN - Globe of Science and Innovation 20 and 21 October Acrobatics, mime, a cappella singing, projections of images, a magical setting... a host of different tools of a grandeur matching that of the Universe they relate. A camera makes a massive zoom out to reveal the multiple dimensions of Nature. Freeze the frame: half way between the infinitesimally small and the infinitesimally large, a man suspends his everyday life (hence the title "Point de Suspension", which refers to the three dots at the end of an uncompleted sentence) to take a glimpse of the place he occupies in the great history of the Universe. An unusual perspective on what it means to be a human being... This wondrous show in the Globe of Science and Innovation, specially created by the Miméscope* company for the official ceremony marking CERN's fiftieth anniversary, is a gift from the Government of the Republic and Canton of Geneva, which also wishes to share this moment of wonder with the local population. There will be three perfo...

  1. "Point de suspension"

    CERN Multimedia

    2004-01-01

    http://www.cern.ch/cern50/ CERN - Globe of Science and Innovation 20 and 21 October Acrobatics, mime, a cappella singing, projections of images, a magical setting... a host of different tools of a grandeur matching that of the Universe they relate. A camera makes a massive zoom out to reveal the multiple dimensions of Nature. Freeze the frame: half way between the infinitesimally small and the infinitesimally large, a man suspends his everyday life (hence the title "Point de Suspension", which refers to the three dots at the end of an uncompleted sentence) to take a glimpse of the place he occupies in the great history of the Universe. An unusual perspective on what it means to be a human being... This wondrous show in the Globe of Science and Innovation, specially created by the Miméscope* company for the official ceremony marking CERN's fiftieth anniversary, is a gift from the Government of the Republic and Canton of Geneva, which also wishes to share this moment of wonder with the local pop...

  2. "Point de suspension"

    CERN Multimedia

    2004-01-01

    CERN - Globe of Science and Innovation 20 and 21 October Acrobatics, mime, a cappella singing, projections of images, a magical setting... a host of different tools of a grandeur matching that of the Universe they relate. A camera makes a massive zoom out to reveal the multiple dimensions of Nature. Freeze the frame: half way between the infinitesimally small and the infinitesimally large, a man suspends his everyday life (hence the title "Point de Suspension", which refers to the three dots at the end of an uncompleted sentence) to take a glimpse of the place he occupies in the great history of the Universe. An unusual perspective on what it means to be a human being... This spectacle in the Globe of Science and Innovation, specially created by the Miméscope* company for the official ceremony marking CERN's fiftieth anniversary, is a gift from the Government of the Republic and Canton of Geneva, which also wishes to share this moment of wonder with the local population. There will be three performances for...

  3. Comparison of cortisol exposures and pharmacodynamic adrenal steroid responses to hydrocortisone suspension vs. commercial tablets.

    Science.gov (United States)

    Sarafoglou, Kyriakie; Gonzalez-Bolanos, Maria T; Zimmerman, Cheryl L; Boonstra, Timothy; Yaw Addo, O; Brundage, Richard

    2015-04-01

    The Endocrine Society Clinical Practice Guidelines on congenital adrenal hyperplasia (CAH) recommend against using hydrocortisone suspension based on a study that examined a commercial suspension. Our objective was to examine the absorption of an extemporaneously prepared hydrocortisone suspension and compare it to tablets. Secondary objectives were to evaluate the 17-hydroxyprogesterone and androstenedione adrenal steroid responses. Using a parallel design, 34 children diagnosed with CAH received either suspension (n = 9; median age 1.8 years) or tablets (n = 25; median age 7.5 years). Patients were given their usual morning hydrocortisone formulation and dose; 12 serial blood samples were obtained and the area under the curve (AUC) was calculated. The mg/m(2) dose-normalized cortisol AUCs were no different in the suspension and tablet groups (P = ·06), nor was there a significant difference in the C(max) or T(max) (P = .08 and P = .41, respectively). Although there were no differences in the 17-hydroxyprogesterone change-from-baseline AUCs, baseline concentrations, or the nadir concentrations when comparing suspension and tablet formulations, the androstenedione values were significantly lower as expected in the younger aged suspension group. Our results offer compelling evidence that an extemporaneously prepared hydrocortisone suspension provides comparable cortisol exposures to commercially available tablet formulations in children and can be used to safely and effectively treat CAH. © 2014, The American College of Clinical Pharmacology.

  4. Balanced Flow Meters without Moving Parts

    Science.gov (United States)

    Kelley, Anthony R.; VanBuskirk, Paul

    2008-01-01

    Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced

  5. RFID-BASED Prepaid Power Meter

    OpenAIRE

    Teymourzadeh, Rozita

    2013-01-01

    An Electric power meter is an important component in electric energy service. In the past, many consumers have complained about reading inaccurate of the electric meter. This research presents the development of an electrical power meter equipped with RFID reader. The RFID reader reads a valid RFID card and activates the power meter so that it can supply electricity. When the credit is about low or before the electricity is auto cut off, an SMS message will be sent to the user’s handphone to ...

  6. Cancer-meter: measure and cure.

    Science.gov (United States)

    Kashyap, Sunil Kumar; Sharma, Birendra Kumar; Banerjee, Amitabh

    2017-05-01

    This paper presents a theory and system on "Cancer-Meter'. This idea came through the statement that "cancer is curable if it is measurable". The Cancer-Meter proves that it is possible. This paper proposes the cancer-meter in two ways, theoretical and electronically, as per the measurement and treatment. By the mathematics, first part is defined but the second part is based on computer programming, electrical and electronics. Thus, the cancer-meter is a programmed-electrical-electronic device which measures and cures the cancer both.

  7. Study of the indirect calibration of clinical air kerma-area meters

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Herdade, Silvio B.

    2011-01-01

    Kerma-area product (P KA ) is a quantity which is independent of the distance to the X-ray tube focal spot and that can be used to assess the effective dose in patients. Clinical P KA meters are usually calibrated on-site by measuring the air kerma with an ion chamber and evaluating the irradiated area by means of a radiographic image. This work presents a preliminary metrological evaluation of the calibration of a device marketed recently (PDC, Patient Dose Calibrator, Radcal), designed for calibrating clinical P KA meters. Results are also shown of applying the PDC to the cross calibration of a clinical P KA meter from a radiology equipment. Results confirm a lower energy dependence of the PDC relative to the tested clinical meter. (author)

  8. An accurate and portable solid state neutron rem meter

    Energy Technology Data Exchange (ETDEWEB)

    Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Myers, E.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Fronk, R.G.; Cooper, B.W [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, KS (United States); Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Ugorowski, P.; McGregor, D.S; Shultis, J.K. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2013-08-11

    Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may be classified as a moderating type neutron spectrometer, based on an adaptation to the classical Bonner sphere and position sensitive long counter, which, simultaneously counts thermalized neutrons by high thermal efficiency solid state neutron detectors. The use of multiple detectors and moderator arranged along an axis of symmetry (e.g., long axis of a cylinder) with known neutron-slowing properties allows for the construction of a linear combination of responses that approximate the ambient neutron dose equivalent. Variations on the detector configuration are investigated via Monte Carlo N-Particle simulations to minimize the total instrument mass while maintaining acceptable response accuracy—a dose error less than 15% for bare {sup 252}Cf, bare AmBe, an epi-thermal and mixed monoenergetic sources is found at less than 4.5 kg moderator mass in all studied cases. A comparison of the energy dependent dose equivalent response and resultant energy dependent dose equivalent error of the present dosimeter to commercially-available portable rem meters and the prior art are presented. Finally, the present design is assessed by comparison of the simulated output resulting from applications of several known neutron sources and dose rates.

  9. The investigation in radiation protection of γ-rays material position meter in Guizhou Province

    International Nuclear Information System (INIS)

    Wei Fuxing

    1997-01-01

    The paper investigates the protective property of 38 γ-rays material position meters used in machine vertical kilns by 36 cement factories in Guizhou. Model FLW-II material position meter use the least radioactive source activity and the air absorption dose rate about one meter is equal to the natural background. For model FWJ-77A, the air absorption dose rate around one meter was 1.1-5.3 μGY/h and the average value is 2.1 +- 0.7 μGY/h; for Model LF-I, they are respectively 0.42-6.4 μGY/h and 2.4 +- 0.6 μGY/h. These value are lower than or near to the dose limit value which state stipulated. The biggest dose equivalent that maintenance workers accepted per year is only equal to 1/2∼1/3 of the dose limit value which state stipulated. Some management suggestions for the production, sellment and use of γ-rays material position meter were presented

  10. Relative bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension.

    Science.gov (United States)

    Clemens, Pamela L; Cloyd, James C; Kriel, Robert L; Remmel, Rory P

    2007-01-01

    Maintenance of effective drug concentrations is essential for adequate treatment of epilepsy. Some antiepileptic drugs can be successfully administered rectally when the oral route of administration is temporarily unavailable. Oxcarbazepine is a newer antiepileptic drug that is rapidly converted to a monohydroxy derivative, the active compound. This study aimed to characterise the bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension using a randomised, crossover design in ten healthy volunteers. Two subjects received 300 mg doses of oxcarbazepine suspension via rectal and oral routes and eight received 450 mg doses. A washout period of at least 2 weeks elapsed between doses. The rectal dose was diluted 1:1 with water. Blood samples and urine were collected for 72 hours post-dose. Adverse effects were assessed at each blood collection time-point using a self-administered questionnaire. Plasma was assayed for oxcarbazepine and monohydroxy derivative; urine was assayed for monohydroxy derivative and monohydroxy derivative-glucuronide. Maximum plasma concentration (C(max)) and time to reach C(max) (t(max)) were obtained directly from the plasma concentration-time curves. The areas under the concentration-time curve (AUCs) were determined via non-compartmental analysis. Relative bioavailability was calculated and the C(max) and AUCs were compared using Wilcoxon signed-rank tests. Mean relative bioavailability calculated from plasma AUCs was 8.3% (SD 5.5%) for the monohydroxy derivative and 10.8% (SD 7.3%) for oxcarbazepine. Oxcarbazepine and monohydroxy derivative C(max) and AUC values were significantly lower following rectal administration (p effects were headache and fatigue with no discernible differences between routes. Monohydroxy derivative bioavailability following rectal administration of oxcarbazepine suspension is significantly lower than following oral administration, most likely because of poor oxcarbazepine water

  11. Calculations of dosimetric parameter and REM meter response for BE(d, n) source

    International Nuclear Information System (INIS)

    Chen Changmao

    1988-01-01

    Based on the recent data about neutron spectra, the average energy, effictive energy and conversion coefficient of fluence to dose equivalent are calculated for some Be (α, n) neutron sources which have differene types and structures. The responses of 2202D and 0075 REM meter for thses spectral neutrons are also estimated. The results indicate that the relationship between average energy and conversion coefficient or REM meter responses can be described by simple functions

  12. Testing of Prototype Magnetic Suspension Cryogenic Transfer Line

    Science.gov (United States)

    Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.

    2006-04-01

    A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.

  13. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  14. ORNL Pocket Meter Program: internal operating procedures

    International Nuclear Information System (INIS)

    Berger, C.D.; Miller, J.H.; Dunsmore, M.R.

    1984-12-01

    The ORNL Pocket Meter Program is designed for auditing the approximate photon radiation exposure of Oak Ridge National Laboratory (ORNL) radiation workers. Although pocket meters are considered to be a secondary personnel dosimetry system at ORNL, they are valuable indicators of unplanned exposures if proper procedures are followed for testing, calibrating, deploying, wearing, processing, and recording data. 4 figures, 1 table

  15. Adjustment equipment for reactor radioactivity meter

    International Nuclear Information System (INIS)

    Denisov, V.P.; Malishev, A.N.; Shebanova, L.E.; Kirilyuk, N.A.; Maksimov, Yu.N.; Bessalov, G.G.; Vikhorev, Yu.V.; Lukyanov, M.A.

    1978-01-01

    An activity meter is described movably located in a channel placed in the peripheral biological shielding of a nuclear reactor. It is connected to a weight moving in a second channel by means of a pulley. This arrangement allows locating the radioactivity meter drive on the outer side of the biological shield and vacating space above the reactor body. (Ha)

  16. 10 CFR 451.7 - Metering requirements.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Metering requirements. 451.7 Section 451.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.7 Metering requirements. The net electric energy generated and sold (kilowatt-hours) by the owner or operator of a qualified...

  17. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  18. The reactivity meter and core reactivity

    International Nuclear Information System (INIS)

    Siltanen, P.

    1999-01-01

    This paper discussed in depth the point kinetic equations and the characteristics of the point kinetic reactivity meter, particularly for large negative reactivities. From a given input signal representing the neutron flux seen by a detector, the meter computes a value of reactivity in dollars (ρ/β), based on inverse point kinetics. The prompt jump point of view is emphasised. (Author)

  19. Fatigue Life Prediction of Package of Suspension Automotive Under Random Vibration Based on Road Roughness

    Directory of Open Access Journals (Sweden)

    Kazem Reza Kashyzadeh

    2015-09-01

    Full Text Available The impact of a suitable suspension system for passenger comfort and vehicle steering is an obvious order and direct impact on the safety of passengers must be considered, to do so different kinds of tests must be exerted, one of these is fatigue testing which is one of the most significant ones. Another issue is the high cost in practical ways, and to cope with this issue various ways must be assessed and analyzed, one of the best and the most efficient ways is modelling and testing in virtual software environments. In the present paper, predict fatigue life of suspension component and package of automotive suspension are the main purposes. First, using MATLAB software, road roughness according to the intercity roads for constant vehicle velocity (100 Km/h has been studied. After that frequency response of components has been analysed, its critical points determined to calculate the fatigue life of the part, and the amount of critical stress obtained based on Von Misses, Tresca and Max Principle criterion for a quarter car model (passive suspension System in 206 Peugeot. Fatigue life of the vehicle components are calculated in terms of kilo-Meters in specialized fatigue software such as 116944, 92638.9, 46388.9 and 191388.9 Km respectively wheel hub, pitman arm, suspension arm and package of suspension. Finally, to prove the given results of the finite element method compared with reported results by other researchers and the results match very well with those.

  20. Ambiguity effects of rhyme and meter.

    Science.gov (United States)

    Wallot, Sebastian; Menninghaus, Winfried

    2018-04-23

    Previous research has shown that rhyme and meter-although enhancing prosodic processing ease and memorability-also tend to make semantic processing more demanding. Using a set of rhymed and metered proverbs, as well as nonrhymed and nonmetered versions of these proverbs, the present study reveals this hitherto unspecified difficulty of comprehension to be specifically driven by perceived ambiguity. Roman Jakobson was the 1st to propose this hypothesis, in 1960. He suggested that "ambiguity is an intrinsic, inalienable feature" of "parallelistic" diction of which the combination of rhyme and meter is a pronounced example. Our results show that ambiguity indeed explains a substantial portion of the rhyme- and meter-driven difficulty of comprehension. Longer word-reading times differentially reflected ratings for ambiguity and comprehension difficulty. However, the ambiguity effect is not "inalienable." Rather, many rhymed and metered sentences turned out to be low in ambiguity. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  1. Hydro Ottawa achieves Smart Meter milestone

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    As Ontario's second largest municipal electricity company, Hydro Ottawa serves more than 285,000 residential and business customers in the city of Ottawa and the village of Casselman. Since 2006, the utility has installed more than 230,000 Smart Meters throughout its service territory in an effort to provide better services to its customers. This initiative represents the largest operational advanced metering infrastructure network in Canada. This move was necessary before time-of-use rates can be implemented in Ottawa. The Smart Meters deliver data wirelessly to Hydro Ottawa's Customer Information System for billing and eliminating manual readings. The Smart Meters are designed to promote more efficient use of electricity. The Government of Ontario has passed legislation requiring the installation of Smart Meters throughout the province by the end of 2010

  2. Active Control of Suspension Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper some recent research on active control of very long suspension bridges, is presented. The presentation is based on research work at Aalborg University, Denmark. The active control system is based on movable flaps attached to the bridge girder. Wind load on bridges with or without...... flaps attached to the girder is briefly presented. A simple active control system is discussed. Results from wind tunnel experiments with a bridge section show that flaps can be used effectively to control bridge girder vibrations. Flutter conditions for suspension bridges with and without flaps...

  3. Digital Survey Meter based on PIC16F628 Microcontroller

    International Nuclear Information System (INIS)

    Al-Mohamad, A.; Shliwitt, J.

    2010-01-01

    A Digital Survey Meter based on PIC16F628 Microcontroller was designed using simple Geiger-Muller Counter ZP1320 made by Centronic in the UK as detector. The sensitivity of this tube is about 9 counts/s at 10μGy/h. It is sensitive to gamma and beta particles over 0.25 MeV. It has a sensitive length of 28mm. Count rate versus dose rate is quite linear up to about 10 4 counts/s. Indication is given by a speaker which emits one click for each count. In addition to the acoustic alarm, the meter works according one of three different measurement modes selected using appropriate 3 states switch: 1- Measurement of Dose rate ( in μGy/h) and counting rate ( in CPS) , for High counting rates. 2- Measurement of Dose rate ( in μGy/h) and counting rate ( in CPM), for Low counting rates. 3- Accumulated Counting with continues display for No. of Counts and Counting Time with a period of 2 Sec. The results are Displayed on an Alphanumerical LCD Display, and the circuit will give many hours of operation from a single 9V PP3 battery. The design of the circuit combines between accuracy, simplicity and low power consumption. We built 2 Models of this design, the first only with an internal detector, and the second is equipped with an External Detector. (author)

  4. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    In the later years, there has been an increased focus on new valve types, which yield the possibility to do Separate Meter-In Separate Meter-Out (SMISMO) control. This includes both digital valves, but proportional valves with separate metering spools and build in pressure sensors are also emerging....... The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...

  5. Sector smart meter audit review report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-03-31

    This paper presented the results of an electricity distributor sector smart meter audit review conducted by the Ontario Energy Board (OEB) for the period of January 1, 2006 to September 30, 2009. The review summarized the results of a questionnaire related to distributors' smart meter regulatory accounting treatment. Seventy-eight distributors responded to the survey. The review included details of: (1) total investments in smart metering initiative for capital expenditures (CAPEX) and operating maintenance and administrative expenses (OM and A), (2) funding dollars received by the distributors, (3) board-approved recoveries for CAPEX and OM and A, (4) recorded stranded meter costs, and (5) number of smart meters installed in the review period. The audit review demonstrated that some distributors incorrectly recorded carrying charges related to smart meter OM and A expenses, and that some smart meter transactions were recorded in accounts other than OEB established accounts in the general ledger. Results of the audit will be used to provide further accounting assistance to electricity distributors. 7 tabs.

  6. Four-Wheel Vehicle Suspension System

    Science.gov (United States)

    Bickler, Donald B.

    1990-01-01

    Four-wheel suspension system uses simple system of levers with no compliant components to provide three-point suspension of chassis of vehicle while maintaining four-point contact with uneven terrain. Provides stability against tipping of four-point rectangular base, without rocking contact to which rigid four-wheel frame susceptible. Similar to six-wheel suspension system described in "Articulated Suspension Without Springs" (NPO-17354).

  7. Heavy vehicle pitch dynamics and suspension tuning

    OpenAIRE

    Cao, Dongpu; Rakheja, Subhash; Su, Chun-Yi

    2008-01-01

    The influence of suspension tuning of passenger cars on bounce and pitch ride performance has been explored in a number of studies, while only minimal efforts have been made for establishing similar rules for heavy vehicles. This study aims to explore pitch dynamics and suspension tunings of a two-axle heavy vehicle with unconnected suspension, which could also provide valuable information for heavy vehicles with coupled suspensions. Based on a generalised pitch-plane model of a two-axle heav...

  8. Water metering in England and Wales

    Directory of Open Access Journals (Sweden)

    David Zetland

    2016-02-01

    Full Text Available The transformation of water services that began with the privatisation of water companies in 1989 extended to households with the implementation of water metering. Meters 'privatised' water and the cost of provision by allocating to individual households costs that had previously been shared within the community. This (ongoing conversion of common pool to private good has mostly improved economic, environmental and social impacts, but the potential burden of metering on poorer households has slowed the transition. Stronger anti-poverty programmes would be better at addressing this poverty barrier than existing coping mechanisms reliant on subsidies from other water consumers.

  9. Hydrogen meter for service in liquid sodium

    International Nuclear Information System (INIS)

    McCown, J.J.

    1983-11-01

    This standard establishes the requirements for the design, materials, fabrication, quality assurance, examination, and acceptance testing of a hydrogen meter and auxiliary equipment for use in radioactive or nonradioactive liquid sodium service. The meter shall provide a continuous and accurate indication of the hydrogen impurity concentration over the range 0.03 to 10 ppM hydrogen in sodium at temperatures between 800 and 1000 0 F (427 and 538 0 C). The meter may also be used to rapidly monitor changes in hydrogen concentration, over the same concentration range, and, therefore can be used as a sensor for sodium-water reactions in LMFBR steam generators

  10. Suspension-Firing of Biomass

    DEFF Research Database (Denmark)

    Shafique Bashir, Muhammad; Jensen, Peter Arendt; Frandsen, Flemming

    2012-01-01

    This paper is the second of two papers, describing probe measurements of deposit buildup and removal (shedding), conducted in a 350 MWth suspension-fired boiler, firing straw and wood. Investigations of deposit buildup and shedding have been made by use of an advanced online deposit probe and a s...

  11. Suspension-Firing of Biomass

    DEFF Research Database (Denmark)

    Bashir, Muhammad Shafique; Jensen, Peter Arendt; Frandsen, Flemming

    2012-01-01

    This paper is Part 1 in a series of two describing probe measurements of deposit build-up and removal (shedding) in a 350 MWth suspension boiler, firing straw and wood. The influence of fuel type (straw share in wood), probe exposure time, probe surface temperature (500, 550, and 600 °C), and flu...

  12. Nonlinear models of suspension bridges

    Czech Academy of Sciences Publication Activity Database

    Malík, Josef

    2006-01-01

    Roč. 321, č. 2 (2006), s. 828-850 ISSN 0022-247X Institutional research plan: CEZ:AV0Z30860518 Keywords : suspension bridges * principle of minimum energy Subject RIV: BA - General Mathematics Impact factor: 0.758, year: 2006

  13. Fracture in Kaolinite clay suspensions

    Science.gov (United States)

    Kosgodagan Acharige, Sebastien; Jerolmack, Douglas J.; Arratia, Paulo E.

    2017-11-01

    Clay minerals are involved in many natural (landslides, river channels) and industrial processes (ceramics, cosmetics, oil recovery). They are plate shaped charged colloids and exhibit different flow properties than simpler colloids when suspended in a liquid such as thixotropy and shear-banding. kaolinite platelets are non-swelling, meaning that the stacks formed by the platelets do not have water layers, and thus the suspension does not have a sol-gel transition. However, it has been shown that kaolinite suspensions possesses a non-zero yield stress even at low concentrations, indicating that the particles arrange themselves in a structure through attractive interactions. Here, we experimentally investigate the sedimentation of kaolinite suspensions in a Hele-Shaw cell. The sedimentation of these dilute suspensions can display solid behavior like fracture, revealed in cross-polarized light, which is linked to the failure of the weakly-bonded structure (typical yield stress 10-2 Pa). By changing the interaction potential of the particles (by sonication or introducing salts), we show through these sedimentation experiments, how the fracture pattern can be avoided. Research was sponsored by the Army Research Laboratory and was accomplished under Grant Number 569074.

  14. Preparation of 0.05% FK506 suspension eyedrops and its pharmacokinetics after topical ocular administration.

    Science.gov (United States)

    Yuan, Jin; Zhai, Jia-jie; Chen, Jia-qi; Ye, Cheng-tian; Zhou, Shi-you

    2009-08-01

    To investigate the stability of FK506 eye suspension and its pharmacokinetics in rabbit aqueous humor, as well as its distribution in eye tissues. Sedimentation rate, flocculation value, redispersion time, rheological study, and accelerated experiment were determined for evaluating the stability of FK506 suspension. In a single-dose pharmacokinetic study, six rabbits were instilled a 25-microL drop of 0.05% FK506 suspension and aqueous humor samples were collected at different intervals after administration. In a multiple-dose pharmacokinetic study, a 25-microL drop of FK506 suspension was instilled into the right eye of six rabbits four times a day for 7 days. On the eighth day, aqueous humor samples were collected before the administration of the first, second, third dose, and at different checkpoints after the third dose. For tissue distribution study, six eyes per time points (18 rabbits in total) were treated with single dose of FK506 suspension, and the eyes were enucleated at 60, 100, and 240 min after treatment, then eye tissues were collected. The concentrations of FK506 in all samples were determined by LC-MS/MS. The preliminary results indicated that the stability of FK506 suspension was in accord with the standards of Chinese pharmacopoeia. The maximum concentrations of aqueous humor after single dose and multiple dose administrations were 31.40 +/- 9.32 ng/mL and 37.73 +/- 11.25 ng/mL, respectively. The concentration of FK506 in cornea at 60, 100, and 240 min after a single dose were 402.0 +/- 96.8 ng/g, 363.8 +/- 84.5 ng/g, and 220 +/- 62.3 ng/g, respectively. Determination of pharmacokinetic parameters of single-dose and multiple-dose administration, as well as the FK506 concentrations in eye tissues, showed that the FK506 formulation and the dosing regimen ensured the therapeutic concentration of FK506 for treating corneal allograft rejection. Based on the stability, single-dose and multiple-dose pharmacokinetics, and tissue distribution, FK506

  15. Net metering study of switching effects on electromechanical meters[Report prepared for the Measurement Canada Electricity Net Metering Project

    Energy Technology Data Exchange (ETDEWEB)

    Van Overberghe, L. [Measurement Canada, London, ON (Canada)

    2006-03-03

    The feasibility of introducing net metering in the electricity sector was evaluated with particular reference to a project administered by Measurement Canada and Electro-Federation Canada (MicroPower Connect) in collaboration with Natural Resources Canada. The objective of the Measurement Canada Electricity Net Metering Project is to identify and eliminate the barriers introduced by the Electricity and Gas Inspection Act regarding the introduction of net metering. The purpose was to design a device that would allow rotation reversal in a residential electromechanical single phase meter. The device should approximate any fluctuations found in a typical net metering system. A series of tests were conducted to understand the influences, on errors, of forward-to-reverse and reverse-to-forward transitions, specifically to find evidence of error migration and mechanical stress. The project was designed to find and measure the effects of forward reverse switching on an electromechanical meter resulting from a change in energy flow. Twenty metres were calibrated in the forward direction in series from light load to high load. Power factor was not adjustable. Test points were then applied in both the forward and reverse directions. The exercise yielded individual errors which were aggregated to show average found errors after 3,000 transitions. Small shifts in errors were apparent and there was no evidence to support a disk flutter theory. refs., tabs., figs.

  16. 49 CFR 570.8 - Suspension systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Suspension systems. 570.8 Section 570.8 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Pounds or Less § 570.8 Suspension systems. (a) Suspension condition. Ball joint seals shall not be cut or...

  17. 49 CFR 570.61 - Suspension system.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Suspension system. 570.61 Section 570.61... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION VEHICLE IN USE INSPECTION STANDARDS Vehicles With GVWR of More Than 10,000 Pounds § 570.61 Suspension system. (a) Suspension condition. Ball joint seals shall not be cut...

  18. Bandwidth Analysis of Smart Meter Network Infrastructure

    DEFF Research Database (Denmark)

    Balachandran, Kardi; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2014-01-01

    Advanced Metering Infrastructure (AMI) is a net-work infrastructure in Smart Grid, which links the electricity customers to the utility company. This network enables smart services by making it possible for the utility company to get an overview of their customers power consumption and also control...... devices in their costumers household e.g. heat pumps. With these smart services, utility companies can do load balancing on the grid by shifting load using resources the customers have. The problem investigated in this paper is what bandwidth require-ments can be expected when implementing such network...... to utilize smart meters and which existing broadband network technologies can facilitate this smart meter service. Initially, scenarios for smart meter infrastructure are identified. The paper defines abstraction models which cover the AMI scenarios. When the scenario has been identified a general overview...

  19. USGS Digital Orthophoto Quad (DOQ) - 3 meter

    Data.gov (United States)

    Minnesota Department of Natural Resources — These data files are a collection of the USGS standard DOQs that have been resampled to a 3-meter cell resolution and mosaiced into quad format vs quarter quad...

  20. A simple reactivity-meter system

    International Nuclear Information System (INIS)

    Ferreira, P.S.B.

    1992-01-01

    This paper describes a new version of a reactivity meter developed at the Institute of Nuclear Energy Research (IPEN) (Brazil). The reactivity meter computes the reactor reactivity utilizing a programmable electrometer that performs the data aquisition. The software commands the main functions of the electrometer, the data acquisition, data transfer, and reactivity calculation. The necessary hardware for this reactivity meter are a programmable electrometer, a microcomputer, and interfaces for the microcomputer to communicate with the electrometer. If it is necessary, it is possible to connect a graphic register to the microcomputer. With this conventional hardware, available in any nuclear reactor facility, one can build a powerful reactivity meter. Adding to these advantages, one can use the microcomputer on-line to analyze the data, store the data on diskettes, or create graphics

  1. New consumer services provided by smart metering

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2015-01-01

    Full Text Available This paper focuses on the issues of smart metering market and considers different services provided by smart metering from consumer point of view. Firstly, smart metering deployment challenges emerging and conventional tariffs, which modify a consumer behavior and thus, the entire electric energy market can be optimized since the customer is motivated to consume less energy. Secondly, the authors illustrate changes in electricity quality, which have an impact on consumer relations with utility. Additionally, two main indices of grid resilience – SAIDI and SAIFI – are exemplified to reveal the improvement potential of smart metering implementation in certain regions of Russia that also influence the consumer. Finally, in-home display and privacy problem directly reflect the consumer’s behavior, thus the private life rights should not be violated as they are guaranteed by law.

  2. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Directory of Open Access Journals (Sweden)

    Zhi-Ting Lin

    2010-06-01

    Full Text Available Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  3. EMMNet: sensor networking for electricity meter monitoring.

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  4. Opportunities for smart meters in Germany

    International Nuclear Information System (INIS)

    Wolff, J.

    2010-10-01

    Germany has the ambitious goal of lowering its CO2 emission with 80 percent until 2050 as compared to 1990. Sustainable energy and the deployment of smart meters are starting to play increasingly important roles. [nl

  5. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  6. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  7. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  8. Intelligent Metering for Urban Water: A Review

    Directory of Open Access Journals (Sweden)

    Rodney Stewart

    2013-07-01

    Full Text Available This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been driven by the desire for increased data regarding time of use and end-use (such as use by shower, toilet, garden, etc. as well as by the ability of the technology to reduce labour costs for meter reading. Technology development in the water sector generally lags that seen in the electricity sector. In the coming decade, the deployment of intelligent water metering will transition from being predominantly “pilot or demonstration scale” with the occasional city-wide roll-out, to broader mainstream implementation. This means that issues which have hitherto received little focus must now be addressed, namely: the role of real-time data in customer engagement and demand management; data ownership, sharing and privacy; technical data management and infrastructure security, utility workforce skills; and costs and benefits of implementation.

  9. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  10. Suspensions with reduced violin string modes

    International Nuclear Information System (INIS)

    Lee, B H; Ju, L; Blair, D G

    2006-01-01

    We discuss the possibility of significantly reducing the number and Q-factor of violin string modes in the mirror suspension. Simulations of a bar-flexure suspension and an orthogonal ribbon have shown a reduction in the number of violin string modes when compared to a normal ribbon suspension. By calculating the expected suspension thermal noise, we find that the orthogonal ribbon provides a promising suspension alternative. A lower number of violin modes oscillating in the direction of the laser and a reduction in violin mode peak values of at least 23dB can be achieved with a slight increase in thermal noise above 40Hz

  11. Suspensions with reduced violin string modes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B H; Ju, L; Blair, D G [School of Physics, University of Western Australia, Crawley 6009, WA (Australia)

    2006-03-02

    We discuss the possibility of significantly reducing the number and Q-factor of violin string modes in the mirror suspension. Simulations of a bar-flexure suspension and an orthogonal ribbon have shown a reduction in the number of violin string modes when compared to a normal ribbon suspension. By calculating the expected suspension thermal noise, we find that the orthogonal ribbon provides a promising suspension alternative. A lower number of violin modes oscillating in the direction of the laser and a reduction in violin mode peak values of at least 23dB can be achieved with a slight increase in thermal noise above 40Hz.

  12. Characteristic tests of ionization chamber and GM counter survey meters for beta-rays, (2)

    International Nuclear Information System (INIS)

    Suga, Shin-ichi; Bingo, Kazuyoshi; Kajimoto, Yoichi

    1979-03-01

    To estimate a beta-ray absorbed dose rate of contaminated skin, measurements were done twice by a survey meter without and with a filter, keeping the distance from the contaminated skin surface to the survey meter at 10 mm. The absorbed dose rate was obtained multiplying a net reading (equals a reading of survey meter's indicator measured without the filter minus that measured with the filter) by a multiplying factor. Calibrations were made with reference plane sources of natural uranium, 198 Au and 204 Tl, varying their area. The five types of ionization chamber survey meters had nearly same multiplying factors when the diameter of source was larger than the diameter of the chamber cylinder. Estimation of the absorbed doses due to beta-emitting nuclides was possible when the measured value without filter was larger by 20% or more than that of with filter. In the case of small sources, the multiplying factor varied significantly with area of the source. The multiplying factors agreed within +-30% in the respective types i.e. manufacturers and in maximum beta-ray energies from 0.7 up to 2.5 MeV. In the source to detector distance of 1 cm +-0.2 cm, the multiplying factor varied within +-20%. The multiplying factor of a GM counter survey meter varied with beta-ray energy, the multiplying factor for uranium was 1/3 that of 204 Tl. (author)

  13. Smart meters. Smart metering. A solution module for a future-oriented energy system; Intelligente Zaehler. Smart Metering. Ein Loesungsbaustein fuer ein zukunftsfaehiges Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Nadia; Seidl, Hans [comps.

    2011-12-15

    The German Energy Agency GmbH (Berlin, Federal Republic of Germany) reports on smart metering as a solution module for a future-oriented energy system by means of the following contributions: (1) Key role for smart meters; (2) What is smart metering? (3) Implementation of smart metering in Europe; (4) The market development to date in Germany; (5) Practical experiences with smart metering in Germany; (6) Frequently asked questions; (7) Smart metering in intelligent networks; (8) Legal framework conditions; (9) Data security and data protection in the utilisation of smart meters; (10) Ongoing information; (11) Efficient energy systems.

  14. Calibration methodology application of kerma area product meters in situ: Preliminary results

    Science.gov (United States)

    Costa, N. A.; Potiens, M. P. A.

    2014-11-01

    The kerma-area product (KAP) is a useful quantity to establish the reference levels of conventional X-ray examinations. It can be obtained by measurements carried out with a KAP meter on a plane parallel transmission ionization chamber mounted on the X-ray system. A KAP meter can be calibrated in laboratory or in situ, where it is used. It is important to use one reference KAP meter in order to obtain reliable quantity of doses on the patient. The Patient Dose Calibrator (PDC) is a new equipment from Radcal that measures KAP. It was manufactured following the IEC 60580 recommendations, an international standard for KAP meters. This study had the aim to calibrate KAP meters using the PDC in situ. Previous studies and the quality control program of the PDC have shown that it has good function in characterization tests of dosimeters with ionization chamber and it also has low energy dependence. Three types of KAP meters were calibrated in four different diagnostic X-ray equipments. The voltages used in the two first calibrations were 50 kV, 70 kV, 100 kV and 120 kV. The other two used 50 kV, 70 kV and 90 kV. This was related to the equipments limitations. The field sizes used for the calibration were 10 cm, 20 cm and 30 cm. The calibrations were done in three different cities with the purpose to analyze the reproducibility of the PDC. The results gave the calibration coefficient for each KAP meter and showed that the PDC can be used as a reference instrument to calibrate clinical KAP meters.

  15. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  16. KFM: a homemade yet accurate and dependable fallout meter

    International Nuclear Information System (INIS)

    Kearny, C.H.; Barnes, P.R.; Chester, C.V.; Cortner, M.W.

    1978-01-01

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of +-25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The step-by-step illustrated instructions for making and using a KFM are presented. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM

  17. Tunable, Quantitative Fenton-RAFT Polymerization via Metered Reagent Addition.

    Science.gov (United States)

    Nothling, Mitchell D; McKenzie, Thomas G; Reyhani, Amin; Qiao, Greg G

    2018-05-10

    A continuous supply of radical species is a key requirement for activating chain growth and accessing quantitative monomer conversions in reversible addition-fragmentation chain transfer (RAFT) polymerization. In Fenton-RAFT, activation is provided by hydroxyl radicals, whose indiscriminate reactivity and short-lived nature poses a challenge to accessing extended polymerization times and quantitative monomer conversions. Here, an alternative Fenton-RAFT procedure is presented, whereby radical generation can be finely controlled via metered dosing of a component of the Fenton redox reaction (H 2 O 2 ) using an external pumping system. By limiting the instantaneous flux of radicals and ensuring sustained radical generation over tunable time periods, metered reagent addition reduces unwanted radical "wasting" reactions and provides access to consistent quantitative monomer conversions with high chain-end fidelity. Fine tuning of radical concentration during polymerization is achieved simply via adjustment of reagent dose rate, offering significant potential for automation. This modular strategy holds promise for extending traditional RAFT initiation toward more tightly regulated radical concentration profiles and affords excellent prospects for the automation of Fenton-RAFT polymerization. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Robust Meter Network for Water Distribution Pipe Burst Detection

    OpenAIRE

    Donghwi Jung; Joong Hoon Kim

    2017-01-01

    A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal me...

  19. Chain Dynamics in Magnetorheological Suspensions

    Science.gov (United States)

    Gast, A. P.; Furst, E. M.

    1999-01-01

    Magnetorheological (MR) suspensions are composed of colloidal particles which acquire dipole moments when subjected to an external magnetic field. At sufficient field strengths and concentrations, the dipolar particles rapidly aggregate to form long chains. Subsequent lateral cross-linking of the dipolar chains is responsible for a rapid liquid-to-solid-like rheological transition. The unique, magnetically-activated rheological properties of MR suspensions make them ideal for interfacing mechanical systems to electronic controls. Additionally, the ability to experimentally probe colloidal suspensions interacting through tunable anisotropic potentials is of fundamental interest. Our current experimental work has focused on understanding the fluctuations of dipolar chains. It has been proposed by Halsey and Toor (HT) that the strong Landau-Peierls thermal fluctuations of dipolar chains could be responsible for long-range attractions between chains. Such interactions will govern the long-time relaxation of MR suspensions. We have synthesized monodisperse neutrally buoyant MR suspensions by density matching stabilized ferrofluid emulsion droplets with D2O. This allows us to probe the dynamics of the dipolar chains using light scattering without gravitational, interfacial, and polydispersity effects to resolve the short-wavelength dynamics of the dipolar chains. We used diffusing wave spectroscopy to measure these dynamics. The particle displacements at short times that show an independence to the field strength, but at long times exhibit a constrained, sub-diffusive motion that slows as the dipole strength is increased. The experiments are in good qualitative agreement with Brownian dynamics simulations of dipolar chains. Although there have been several important and detailed studies of the structure and interactions in MR suspensions, there has not been conclusive evidence that supports or contradicts the HT model prediction that long-range interactions exist between

  20. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  1. Particle Suspension Mechanisms - Supplemental Material

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, M B

    2011-03-03

    This supplemental material provides a brief introduction to particle suspension mechanisms that cause exfoliated skin cells to become and remain airborne. The material presented here provides additional context to the primary manuscript and serves as background for designing possible future studies to assess the impact of skin cells as a source of infectious aerosols. This introduction is not intended to be comprehensive and interested readers are encouraged to consult the references cited.

  2. Robust Tensioned Kevlar Suspension Design

    Science.gov (United States)

    Young, Joseph B.; Naylor, Bret J.; Holmes, Warren A.

    2012-01-01

    One common but challenging problem in cryogenic engineering is to produce a mount that has excellent thermal isolation but is also rigid. Such mounts can be achieved by suspending the load from a network of fibers or strings held in tension. Kevlar fibers are often used for this purpose owing to their high strength and low thermal conductivity. A suite of compact design elements has been developed to improve the reliability of suspension systems made of Kevlar.

  3. Polymorphism in Bacterial Flagella Suspensions

    Science.gov (United States)

    Schwenger, Walter J.

    Bacterial flagella are a type of biological polymer studied for its role in bacterial motility and the polymorphic transitions undertaken to facilitate the run and tumble behavior. The naturally rigid, helical shape of flagella gives rise to novel colloidal dynamics and material properties. This thesis studies methods in which the shape of bacterial flagella can be controlled using in vitro methods and the changes the shape of the flagella have on both single particle dynamics and bulk material properties. We observe individual flagellum in both the dilute and semidilute regimes to observe the effects of solvent condition on the shape of the filament as well as the effect the filament morphology has on reptation through a network of flagella. In addition, we present rheological measurements showing how the shape of filaments effects the bulk material properties of flagellar suspensions. We find that the individual particle dynamics in suspensions of flagella can vary with geometry from needing to reptate linearly via rotation for helical filaments to the prevention of long range diffusion for block copolymer filaments. Similarly, for bulk material properties of flagella suspensions, helical geometries show a dramatic enhancement in elasticity over straight filaments while block copolymers form an elastic gel without the aid of crosslinking agents.

  4. Multiphase flow metering: 4 years on

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, G.; Hewitt, G.F.; Alimonti, C.; Harrison, B.

    2005-07-01

    Since the authors' last review in 2001 [1], the use of Multiphase Flow Metering (MFM) within the oil and gas industry continues to grow apace, being more popular in some parts of the world than others. Since the early 1990's, when the first commercial meters started to appear, there have been more than 1,600 field applications of MFM for field allocation, production optimisation and mobile well testing. As the authors predicted, wet gas metering technology has improved to such an extent that its use has rapidly increased worldwide. A ''who's who'' of the MFM sector is provided, which highlights the mergers in the sector and gives an insight into the meters and measurement principles available today. Cost estimates, potential benefits and reliability in the field of the current MFM technologies are revisited and brought up to date. Several measurements technologies have resurfaced, such as passive acoustic energy patterns, infrared wavelengths, Nuclear Magnetic Resonance (NMR) and Electrical Capacitance Tomography (ECT), and they are becoming commercial. The concept of ''virtual metering'', integrated with ''classical MFM'', is now widely accepted. However, sometimes the principles of the MFM measurements themselves are forgotten, submerged in the sales and marketing hype. (author) (tk)

  5. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  6. Privacy friendly aggregation of smart meter readings, even when meters crash

    NARCIS (Netherlands)

    Hoepman, J.H.

    2017-01-01

    A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with

  7. Simple meters get smart? Cost benefit analysis of smart metering infrastructure

    International Nuclear Information System (INIS)

    Van Gerwen, R.J.F.; Jaarsma, S.A.; Koenis, F.T.C.

    2005-08-01

    The Dutch Ministry of Economic Affairs requested a cost-benefit analysis of the large scale introduction of a smart meter infrastructure for gas and electricity consumption by small consumers. The questions asked in the study need to be answered in order to enable a well-founded evaluation of the implementation of smart meters. [mk] [nl

  8. Household Classification Using Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Carroll Paula

    2018-03-01

    Full Text Available This article describes a project conducted in conjunction with the Central Statistics Office of Ireland in response to a planned national rollout of smart electricity metering in Ireland. We investigate how this new data source might be used for the purpose of official statistics production. This study specifically looks at the question of determining household composition from electricity smart meter data using both Neural Networks (a supervised machine learning approach and Elastic Net Logistic regression. An overview of both classification techniques is given. Results for both approaches are presented with analysis. We find that the smart meter data alone is limited in its capability to distinguish between household categories but that it does provide some useful insights.

  9. Implementation plan for smart meters in Ontario

    International Nuclear Information System (INIS)

    2004-01-01

    This paper presents Ontario Energy Board's implementation plan to install 800,000 smart meters by December 31, 2007. The objective is to help consumers control their electricity bills through conservation and demand response. The three conditions that will change power consumption habits are price changes in response to demand and supply forces; the ability of consumers to see and respond to the price signals; and, a measurement of the response so that consumers get credit for their actions. This paper identifies the mandatory technical requirements for smart meters and the support operations of distributors. It sets priorities, identifies barriers and regulatory mechanisms for cost recovery. It also discusses options for ownership of the meters. 18 refs., 1 tab., 2 figs

  10. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  11. Reactor Power Meter type SG-8

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The report describes the principle and electronic circuits of the Reactor Power Meter type SG-8. The gamma radiation caused by the activity of the reactor first cooling circuit affectes the ionization chamber being the detector of the instrument. The output detector signal direct current is converted into the frequency of electric pulses by means of the current-to-frequency converter. The output converter frequency is measured by the digital frequency meter: the number of measured digits in time unit is proportional to the reactor power.

  12. Liquid metal Flow Meter - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  13. Simple, inexpensive computerized rodent activity meters.

    Science.gov (United States)

    Horton, R M; Karachunski, P I; Kellermann, S A; Conti-Fine, B M

    1995-10-01

    We describe two approaches for using obsolescent computers, either an IBM PC XT or an Apple Macintosh Plus, to accurately quantify spontaneous rodent activity, as revealed by continuous monitoring of the spontaneous usage of running activity wheels. Because such computers can commonly be obtained at little or no expense, and other commonly available materials and inexpensive parts can be used, these meters can be built quite economically. Construction of these meters requires no specialized electronics expertise, and their software requirements are simple. The computer interfaces are potentially of general interest, as they could also be used for monitoring a variety of events in a research setting.

  14. Portable digital reactivity meter for power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, G [Nuklear-Ingenieur Service G.m.b.H., Hanau (Germany, F.R.)

    1977-07-01

    A digital reactivity meter has been developed, which can be used for all kinds of kinetic reactivity measurements in PWR's and BWR's. The input signals may be supplied by standard neutron detectors of the reactor. The hardware configuration consists of a minicomputer with ADC and DAC, a 'Silent' terminal and a high speed paper tape reader/punch. It is easily transportable. The reactivity meter solves the inverse kinetics equations for 6 delayed neutron groups, simultaneously for up to 8 logarithmic or linear neutron flux signals. It has been successfully tested at Biblis A PWR and the KRB BWR.

  15. Development of the impedance void meter

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Moon Ki; Song, Chul Hwa; Won, Soon Yeon; Kim, Bok Deuk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    An impedance void meter is developed to measure the area-averaged void fraction. Its basic principle is based on the difference in the electrical conductivity between phases. Several methods of measuring void fraction are briefly reviewed and the reason why this type of void meter is chosen to develop is discussed. Basic principle of the measurement is thoroughly described and several design parameters to affect the overall function are discussed in detail. As example of applications is given for vertical air-water flow. It is shown that the current design has good dynamic response as well as very fine spatial resolution. (Author) 47 refs., 37 figs.

  16. Two-channel neutron boron meter

    International Nuclear Information System (INIS)

    Chen Yongqing; Yin Guowei; Chai Songshan; Deng Zhaoping; Zhou Bin

    1993-09-01

    The two-channel neutron boron meter is a continuous on-line measuring device to measure boron concentration of primary cooling liquid of reactors. The neutron-leakage-compensation method is taken in the measuring mechanism. In the primary measuring configuration, the mini-boron-water annulus and two-channel and central calibration loop are adopted. The calibration ring and constant-temperature of boron-water can be remotely controlled by secondary instruments. With the microcomputer data processing system the boron concentration is automatically measured and calibrated in on-line mode. The meter has many advantages such as high accuracy, fast response, multi-applications, high reliability and convenience

  17. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography

    International Nuclear Information System (INIS)

    Malusek, A.; Sandborg, M.; Alm Carlsson, G.

    2016-01-01

    Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q 0 , to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q 1 , to beam quality, Q. Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography. (authors)

  18. Testing and performance of electrolytic oxygen meters for use in liquid sodium

    International Nuclear Information System (INIS)

    Taylor, R.G.; Thompson, R.

    1983-01-01

    The performance of yttria-doped thoria ceramic electrochemical oxygen meters in liquid sodium is described. Tests were carried out using laboratory loops. Temperature coefficients of the oxygen meters have been measured between 380 0 C and 480 0 C, and the response to changes in oxygen level using cold-trap temperatures from 125 0 C to 250 0 C was determined. The ceramic has been shown to give good performance over lifetimes exceeding 400 days in some cases. The temperature coefficients and response to oxygen level changes are in good agreement with thermodynamic predictions. The effect of running the meters in high-oxygen sodium has been studied and a general mode of failure has been shown to be grain-boundary attack by oxygen/sodium solutions. The effect of #betta#-radiation on the meters has been studied. The meters with a metal/metal oxide reference electrode were unaffected by dose rates up to 52860 mGy h - 1 . Meters with an air reference electrode do show an effect as a voltage reduction at levels down to 2420 mGy h - 1 . This effect was temperature-dependent and was insignificant at 500 0 C. (orig.)

  19. A Probabilistic Model of Meter Perception: Simulating Enculturation

    NARCIS (Netherlands)

    van der Weij, B.; Pearce, M.T.; Honing, H.

    Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter

  20. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  1. 18 CFR 367.9020 - Account 902, Meter reading expenses.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 902, Meter... GAS ACT Operation and Maintenance Expense Chart of Accounts § 367.9020 Account 902, Meter reading... customer meters, and determining consumption when performed by employees engaged in reading meters. (b...

  2. Attractive and repulsive magnetic suspension systems overview

    Science.gov (United States)

    Cope, David B.; Fontana, Richard R.

    1992-01-01

    Magnetic suspension systems can be used in a wide variety of applications. The decision of whether to use an attractive or repulsive suspension system for a particular application is a fundamental one which must be made during the design process. As an aid to the designer, we compare and contrast attractive and repulsive magnetic suspension systems and indicate whether and under what conditions one or the other system is preferred.

  3. Introducing Dual Suspension System in Road Vehicles

    OpenAIRE

    Imtiaz Hussain; Jawaid Daudpoto; Ali Asghar Memon

    2013-01-01

    The main objective of suspension system is to reduce the motions of the vehicle body with respect to road disturbances. The conventional suspension systems in road vehicles use passive elements such as springs and dampers to suppress the vibrations induced by the irregularities in the road. But these conventional suspension systems can suppress vibrations to a certain limit. This paper presents a novel idea to improve the ride quality of roads vehicles without compromising vehicle?s stability...

  4. Assessment of a new p-Mosfet usable as a dose rate insensitive gamma dose sensor

    International Nuclear Information System (INIS)

    Vettese, F.; Donichak, C.; Bourgeault, P.

    1995-01-01

    Dosimetric response of unbiased MOS devices has been assessed at dose rates greater than 2000 cGy/h. Application have been made to a personal dosemeter / dose rate meter to measure the absorbed tissue dose received in the case of acute external irradiation. (D.L.)

  5. Time Varying Behavior of the Loudspeaker Suspension

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2007-01-01

    The suspension part of the electrodynamic loudspeaker is often modelled as a simple linear spring with viscous damping, however the dynamic behaviour of the suspension is much more complicated than predicted by such a simple model. At higher levels the compliance becomes non-linear and often chan...... changes during excitation at high levels. This paper investigates how the compliance of the suspension depends on the excitation, i.e. level and frequency content. The measurements are compared with other known measurement methods of the suspension....

  6. Introducing Dual Suspension System in Road Vehicles

    Directory of Open Access Journals (Sweden)

    Imtiaz Hussain

    2013-04-01

    Full Text Available The main objective of suspension system is to reduce the motions of the vehicle body with respect to road disturbances. The conventional suspension systems in road vehicles use passive elements such as springs and dampers to suppress the vibrations induced by the irregularities in the road. But these conventional suspension systems can suppress vibrations to a certain limit. This paper presents a novel idea to improve the ride quality of roads vehicles without compromising vehicle?s stability. The paper proposes the use of primary and secondary suspension to suppress the vibrations more effectively.

  7. An evaporation based digital microflow meter

    NARCIS (Netherlands)

    Nie, C; Frijns, A J H; Mandamparambil, R; Zevenbergen, M A G; den Toonder, J M J

    2015-01-01

    In this work, we present a digital microflow meter operating in the range 30-250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes

  8. An evaporation based digital microflow meter

    NARCIS (Netherlands)

    Nie, C.; Frijns, A.J.H.; Mandamparambil, R.; Zevenbergen, M.A.G.; Toonder, den J.M.J.

    2015-01-01

    In this work, we present a digital microflow meter operating in the range 30–250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes

  9. Water table and the neutron moisture meter

    Energy Technology Data Exchange (ETDEWEB)

    Visvalingam, M [Hull Univ. (UK). Geography Dept.

    1975-12-01

    Measurements with a neutron moisture meter at Westlands, near Hull, showed count rates at capillary saturation to be within the error limits of count rates at full saturation. However, the saturation profiles in themselves were interesting as they indicated not only the zonation of the soil but also differences in drainable porosity when compared to count-rate profiles at the end of November.

  10. Field test of coordinated ramp metering (CRM).

    Science.gov (United States)

    2017-03-15

    This project has focused on field implementation and testing of a Coordinated Ramp Metering (CRM) algorithm at California State Route 99 : Northbound corridor in Sacramento between Calvine Road and the SR50 interchange after 12th Ave. It is a 9 mile ...

  11. Smart meters and economies in energy use

    International Nuclear Information System (INIS)

    Zelem, Marie-Christine

    2014-01-01

    A central theme promoted by the government for the energy transition, the mastering of energy consumption features notably the setting up of intelligent electricity networks and the installation of what are known as smart meters. Yet will consumers actually be in a position to become proponents of more sober use of energy? (author)

  12. Smart wavelength meter for integrated photonics

    NARCIS (Netherlands)

    Benelajla, Meryem; Taballione, Caterina; Boller, Klaus J.

    2017-01-01

    Thermally tunable SiN waveguide microring resonators in connection with neural network readout algorithms appear promising for use as integrated optical wavelength meters. So far, we have observed long-term reliability and a temperature immunity of the readout across several degrees of ambient

  13. Weak measurements with a qubit meter

    DEFF Research Database (Denmark)

    Wu, Shengjun; Mølmer, Klaus

    2009-01-01

    We derive schemes to measure the so-called weak values of quantum system observables by coupling of the system to a qubit meter system. We highlight, in particular, the meaning of the imaginary part of the weak values, and show how it can be measured directly on equal footing with the real part...

  14. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  15. Wat maakt een slimme meter echt slim?

    NARCIS (Netherlands)

    Smit, Gerardus Johannes Maria; Kokkeler, Andre B.J.; Bakker, Vincent; Bosman, M.G.C.; Molderink, Albert; Croes, Roel

    In de Tweede Kamer laaide in 2008 een discussie op naar aanleiding van geluiden uit de samenleving over het wel of niet verplicht installeren van slimme meters in huizen. Voor- en tegenstanders van een verplichte invoer gebruiken ondertussen alle media om de algemene opinie te beïnvloeden.

  16. Optical system for a universal luminance meter

    NARCIS (Netherlands)

    Schreuder, D.A.

    1965-01-01

    There is a need for luminance meters in various fields of photometry having these characteristics: a- objective method of measurements. b. variable shape and size of measurement area. c- absence of parallax during aiming operations. d- Possibility of observing the part of the field of view to be

  17. Meter Designs Reduce Operation Costs for Industry

    Science.gov (United States)

    2013-01-01

    Marshall Space Flight Center collaborated with Quality Monitoring and Control (QMC) of Humble, Texas, through a Space Act Agreement to design a balanced flow meter for the Space Shuttle Program. QMC founded APlus-QMC LLC to commercialize the technology, which has contributed to 100 new jobs, approximately $250,000 in yearly sales, and saved customers an estimated $10 million.

  18. Cimetidine Pharmacodynamics and Pharmacokinetics in Healthy Subjects: A Comparison of Tablets and Suspension

    Directory of Open Access Journals (Sweden)

    ABR Thomson

    1994-01-01

    Full Text Available The objective of this study was to compare the effect of cimetidine 200 mg tablet with that of cimetidine suspension (200 mg/10 mL, a 20 mL suspension of 800 mg magnesium hydroxide and 912 mg aluminum hydroxide, and matching placebo on intragastric pH of healthy volunteers. There were 13 males and seven females, mean age 23 years (range 20 to 32 and mean weight 72 kg (range 55 to 89. The intragastric pH of each subject was measured over 6 h starting immediately before dosing on each of five study days. Cimetidine plasma levels were measured for 6 h after dosing on each of the cimetidine study days. Cimetidine tablet and suspension were superior to placebo tablet or suspension or to the magnesium hydroxide/aluminum hydroxide suspension in the area under the pH time curve from 0 to 6 h, percentage time pH of at least 3.5, change from pretreatment pH area under the pH time curve (0 to 6 h and maximum increase in pH. Mean plasma cimetidine levels were significantly and positively correlated to mean intragastric pH for both cimetidine tablets and cimetidine suspension. Comparing cimetidine concentration (Cmax and lower percentage time plasma cimetidine concentration was at least 0.5 μg/mL (the minimum therapeutic level. These pharmacokinetic variations between cimetidine suspension and tablets may have partially explained the pharmacodynamic differences of the lower area under the pH time curve (0 to 6 h. The results indicate that both cimetidine tablets and cimetidine suspension significantly increase intragastric pH relative to the magnesium hydroxide/aluminum hydroxide suspension, placebo tablets or placebo suspension. Based on the assumption that elevation of intragastric pH is an important factor for alleviation of the symptoms and for the healing of peptic disorders, the results of this study suggest that both cimetidine tablets and cimetidine suspension should be effective treatment.

  19. KVP meter errors induced by plastic wrap

    International Nuclear Information System (INIS)

    Jefferies, D.; Morris, J.W.; White, V.P.

    1991-01-01

    The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model number-sign 90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique

  20. BCM6: New Generation of Boron Meter

    International Nuclear Information System (INIS)

    Pirat, P.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of boron meter, based on more than 30 years of experience. The Rolls-Royce BCM6 boron meter provides Nuclear Power Plant (NPP) operators with the boron concentration of the primary circuit. The meter provides continuous and safe measurements with no manual sampling and no human contact. In this paper, technical features, advantages and customer benefits of the use of the new generation of Rolls-Royce BCM6 boron meter will be detailed. Values and associated alarms are provides over different media: 4-20 mA outputs, relays, displays in the main control room and in the chemical lab, and digital links. A special alarm avoids unexpected homogeneous dilution of the primary circuit, which is a critical operational parameter. The Rolls-Royce BCM6 boron meter is fully configurable over a set of parameters allowing adaptation to customer needs. It has a differential capability, thus eliminating neutronic noise and keeping measurements accurate, even in the case of fuel clad rupture. Measurements are accurate, reliable, and have a quick response time. Equipment meets state-of-the-art qualification requests. Designed in 2008, the BCM6 boron meter is the newest equipment of Rolls-Royce boron meters product line. It has been chosen to equip the French EPR NPP and complies with the state-of-the-art of the technology. Rolls-Royce has more than 30 years of experience in Instrumentation and Controls with more than 75 NPP units operating worldwide. All of this experience return has been put in this new generation of equipment to provide the customer with the best operation. About Rolls-Royce Rolls-Royce is a global business providing integrated power systems for use on land, at sea and in the air. The Group has a balanced business portfolio with leading market positions. Rolls-Royce has a broad range of civil nuclear expertise, including work related to licensing and safety reviews, engineering design

  1. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  2. Investigation of quality assurance routines of DAP-meters in Swedish hospitals; Kartlaeggning av kvalitetssaekringsrutiner foer DAP-maetare i svensk sjukvaard

    Energy Technology Data Exchange (ETDEWEB)

    Almen, Anja; Grindborg, Jan-Erik; Leitz, Wolfram

    2005-11-01

    The Swedish Radiation Protection Authority has investigated quality control of dose area product meters (DAP meters) used in x-ray diagnostics. A questionnaire was sent out to medical physics experts who are working with diagnostic radiology in Swedish hospitals. This report presents information about the routines practised and gives examples of measures to improve the quality of these practices.

  3. Revealing household characteristics from smart meter data

    International Nuclear Information System (INIS)

    Beckel, Christian; Sadamori, Leyna; Staake, Thorsten; Santini, Silvia

    2014-01-01

    Utilities are currently deploying smart electricity meters in millions of households worldwide to collect fine-grained electricity consumption data. We present an approach to automatically analyzing this data to enable personalized and scalable energy efficiency programs for private households. In particular, we develop and evaluate a system that uses supervised machine learning techniques to automatically estimate specific “characteristics” of a household from its electricity consumption. The characteristics are related to a household's socio-economic status, its dwelling, or its appliance stock. We evaluate our approach by analyzing smart meter data collected from 4232 households in Ireland at a 30-min granularity over a period of 1.5 years. Our analysis shows that revealing characteristics from smart meter data is feasible, as our method achieves an accuracy of more than 70% over all households for many of the characteristics and even exceeds 80% for some of the characteristics. The findings are applicable to all smart metering systems without making changes to the measurement infrastructure. The inferred knowledge paves the way for targeted energy efficiency programs and other services that benefit from improved customer insights. On the basis of these promising results, the paper discusses the potential for utilities as well as policy and privacy implications. - Highlights: • Many household characteristics can be automatically inferred from smart meter data. • We develop a system to infer employment status and number of occupants, for instance. • We evaluate our system analyzing data collected from 4232 households in Ireland. • The insights enable personalized and scalable efficiency campaigns for utilities. • Energy efficiency measures must be complemented by privacy protection

  4. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

    Science.gov (United States)

    Sussman, Allen; Taylor, Elizabeth J; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Lawrence, Andrew; Ng, Ronald

    2012-03-01

    Patients consider multiple parameters in adjusting prandial insulin doses for optimal glycemic control. Difficulties in calculations can lead to incorrect doses or induce patients to administer fixed doses, rely on empirical estimates, or skip boluses. A multicenter study was conducted with 205 diabetes subjects who were on multiple daily injections of rapid/ short-acting insulin. Using the formula provided, the subjects manually calculated two prandial insulin doses based on one high and one normal glucose test result, respectively. They also determined the two doses using the FreeStyle InsuLinx Blood Glucose Monitoring System, which has a built-in, automated bolus calculator. After dose determinations, the subjects completed opinion surveys. Of the 409 insulin doses manually calculated by the subjects, 256 (63%) were incorrect. Only 23 (6%) of the same 409 dose determinations were incorrect using the meter, and these errors were due to either confirmed or potential deviations from the study instructions by the subjects when determining dose with meter. In the survey, 83% of the subjects expressed more confidence in the meter-calculated doses than the manually calculated doses. Furthermore, 87% of the subjects preferred to use the meter than manual calculation to determine prandial insulin doses. Insulin-using patients made errors in more than half of the manually calculated insulin doses. Use of the automated bolus calculator in the FreeStyle InsuLinx meter minimized errors in dose determination. The patients also expressed confidence and preference for using the meter. This may increase adherence and help optimize the use of mealtime insulin. © 2012 Diabetes Technology Society.

  5. Cell suspension culture and mutants selection for resistance to PEG induced water stress in alfalfa (Medicago sativa L.)

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Lin Tingan

    1994-01-01

    Elements affecting suspension cell culture in alfalfa (Medicago sativa L.) were studied and a method of rapid establishment of embryogenic suspension cell lines was introduced. Effects of γ ray irradiation on the growth of suspension cells were studied, and the optimum dose of irradiation for inducing mutants from suspension cells was about 20 ∼ 60 Gy. Effects of PEG and NaCl induced water stress on the growth of suspension cells were also investigated, and the results showed that the congregants of preliminary suspension culture were more susceptible than the established suspension cell lines. With 20 Gy of γ ray irradiation on suspension cell line (JL416), six clones were obtained with 70 days of selection on medium of 15% PEG (about-11 bar). A number of regenerated plants were obtained from these clones. One clone was also gained from medium containing 20% PEG (about-15 bar). The selected mutant cell lines (JP15 and JP20) has strong resistances to high concentration of PEG and NaCl induced water stress

  6. 36 CFR 296.10 - Suspension and revocation of permits.

    Science.gov (United States)

    2010-07-01

    ... AGRICULTURE PROTECTION OF ARCHAEOLOGICAL RESOURCES: UNIFORM REGULATIONS § 296.10 Suspension and revocation of... correct the situation which led to suspension of the permit. (b) Suspension or revocation for management...

  7. Design analysis of formula student race car suspension system

    Science.gov (United States)

    Wirawan, Julian Wisnu; Ubaidillah, Aditra, Rama; Alnursyah, Rafli; Rahman, Rizki Abdul; Cahyono, Sukmaji Indro

    2018-02-01

    Design analysis of suspension especially for racecar suspension is very crucial to achieve maximum performance and handling. Suspension design may vary depending on the road terrain and the vehicle purpose itself, such as high speed or off-road vehicle. This paper focused on the suspension which used for racecar vehicle. The suspension type used was unequal double wishbone. This model is used because of its stability for high-speed usage compared to another kind of suspension. The suspension parameter was calculated to achieve desired performance. The result is the motion ratio of the designed suspension geometry. The obtained value of motion ratio was 1:2 for front suspension and 1:1 for the rear suspension. These calculation result the front suspension is still too soft, which the optimal motion ratio should be kept around 1:1 for better handling. This problem caused by the lack of space for suspension linkage.

  8. 39 CFR 320.9 - Revocation or amendment of suspensions.

    Science.gov (United States)

    2010-07-01

    ... SUSPENSION OF THE PRIVATE EXPRESS STATUTES § 320.9 Revocation or amendment of suspensions. These suspensions... of operations (in dollar or volume terms, whichever is larger) lower than that antedating the...

  9. Kineto-dynamic design optimisation for vehicle-specific seat-suspension systems

    Science.gov (United States)

    Shangguan, Wen-Bin; Shui, Yijie; Rakheja, Subhash

    2017-11-01

    Designs and analyses of seat-suspension systems are invariably performed considering effective vertical spring rate and damping properties, while neglecting important contributions due to kinematics of the widely used cross-linkage mechanism. In this study, a kineto-dynamic model of a seat-suspension is formulated to obtain relations for effective vertical suspension stiffness and damping characteristics as functions of those of the air spring and the hydraulic damper, respectively. The proposed relations are verified through simulations of the multi-body dynamic model of the cross-linkage seat-suspension in the ADAMS platform. The validity of the kineto-dynamic model is also demonstrated through comparisons of its vibration transmission response with the experimental data. The model is used to identify optimal air spring coordinates to attain nearly constant natural frequency of the suspension, irrespective of the seated body mass and seated height. A methodology is further proposed to identify optimal damping requirements for vehicle-specific suspension designs to achieve minimal seat effective amplitude transmissibility (SEAT) and vibration dose value (VDV) considering vibration spectra of different classes of earthmoving vehicles. The shock and vibration isolation performance potentials of the optimal designs are evaluated under selected vehicle vibration superimposed with shock motions. Results show that the vehicle-specific optimal designs could provide substantial reductions in the SEAT and VDV values for the vehicle classes considered.

  10. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    Science.gov (United States)

    2017-01-03

    following ocular surgery.1 They are available in different forms including emulsions , ointments, solutions, gels, and suspensions. The choice of...study done by Stringer and Bryant compared dose uniformity of difluprednate ophthalmic emulsion (Durezol®) with prednisolone acetate (brand name...topical ophthalmic corticosteroid suspensions. Am J Ophthalmol. 1979;87(2): 210- 214. 5 Flarex® [ package insert]. Fort Worth, TX: Alcon Laboratories Inc

  11. Linear viscoelastic properties of aging suspensions

    NARCIS (Netherlands)

    Purnomo, E.H.; Purnomo, E.H; van den Ende, Henricus T.M.; Mellema, J.; Mugele, Friedrich Gunther

    2006-01-01

    We have examined the linear viscoelastic behavior of poly-N-isopropylacrylamide (PNIPAM) microgel suspensions in order to obtain insight in the aging processes in these densely packed suspensions at various temperatures below the volume transition temperature. The system is found to display a strong

  12. 49 CFR 393.207 - Suspension systems.

    Science.gov (United States)

    2010-10-01

    ... braking system. The vehicle shall be level (not tilting to the left or right). Air leakage shall not be... 49 Transportation 5 2010-10-01 2010-10-01 false Suspension systems. 393.207 Section 393.207... NECESSARY FOR SAFE OPERATION Frames, Cab and Body Components, Wheels, Steering, and Suspension Systems § 393...

  13. 41 CFR 105-74.670 - Suspension.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Suspension. 105-74.670 Section 105-74.670 Public Contracts and Property Management Federal Property Management Regulations System...-GOVERNMENTWIDE REQUIREMENTS FOR DRUG-FREE WORKPLACE (FINANCIAL ASSISTANCE) Definitions § 105-74.670 Suspension...

  14. 36 CFR 25.3 - Supervision; suspensions.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Supervision; suspensions. 25.3 Section 25.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL MILITARY PARKS; LICENSED GUIDE SERVICE REGULATIONS § 25.3 Supervision; suspensions. (a) The guide service will operate under the direction...

  15. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  16. Radiochromic Plastic Films for Accurate Measurement of Radiation Absorbed Dose and Dose Distributions

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Fidan, S.

    1977-01-01

    of dose rate (1–1014 rad s−1). Upon irradiation of the film, the profile of the radiation field is registered as a permanent colored image of the dose distribution. Unlike most other types of dyed plastic dose meters, the optical density produced by irradiation is in most cases stable for periods...... of many polymeric systems in industrial radiation processing. The result is that errors due to energy dependence of response of the radiation sensor are effectively reduced, since the spectral sensitivity of the dose meter matches that of the polymer of interest, over a wide range of photon and electron...

  17. Osmotic consolidation of suspensions and gels

    International Nuclear Information System (INIS)

    Miller, K.T.; Zukoski, C.F.

    1994-01-01

    An osmotic method for the consolidation of suspensions of ceramic particles is demonstrated. Concentrated solutions of poly(ethylene oxide) are separated from a suspension of ceramic particles by a semipermeable membrane, creating a gradient in solvent chemical potential. Solvent passes from the suspension into the polymer solution, lowering its free energy and consolidating the suspension. Dispersions of stable 8-nm hydrous zirconia particles were consolidated to over 47% by volume. Suspensions of α-alumina in three states of aggregation (dispersed, weakly flocculated, and strongly flocculated) were consolidated to densities greater than or equal to those produced in conventional pressure filtration. Moreover, the as-consolidated alumina bodies were partially drained of fluid during the osmotic consolidation process, producing cohesive partially dried bodies with improved handling characteristics

  18. Stability of diclofenac sodium oral suspensions packaged in amber polyvinyl chloride bottles.

    Science.gov (United States)

    Donnelly, Ronald F; Pascuet, Elena; Ma, Carmen; Vaillancourt, Régis

    2010-01-01

    Prescribing of diclofenac for children usually involves a dose different from commercially available strengths. This drug is available only as tablets, which can be divided only so many times before the dose obtained becomes inaccurate. In addition, children may have difficulty swallowing tablets. For these reasons, a compounding formula for a liquid dosage form is essential to ensure effective delivery of the drug to pediatric patients. To develop a compounding formula for diclofenac sodium and to determine the extended physical and chemical stability of this compound when stored in amber polyvinyl chloride (PVC) prescription bottles under refrigeration and at room temperature. A suspension of diclofenac sodium (10 mg/mL) was prepared from commercially available diclofenac sodium tablets, with Ora-Blend as the suspending and flavouring agent. The suspension was packaged in 60-mL amber PVC prescription bottles and stored at either room temperature (23°C) or under refrigeration (5°C). Samples were collected on days 0, 7, 14, 21, 27, 56, and 93. Chemical stability was determined using a validated stability-indicating high-performance liquid chromatography method. At each sampling time, the suspensions were checked for changes in appearance (i.e., colour, layering, caking, ease of resuspension), odour, and pH. The diclofenac sodium suspensions were very stable, retaining at least 99.5% of the original concentration for up to 93 days, regardless of storage temperature. There were no apparent changes in the physical appearance of the suspensions, nor were there any substantial changes in odour or pH. Suspensions of diclofenac sodium (10 mg/mL) were quantitatively stable but difficult to prepare because of the enteric coating of the tablets. Therefore, it is recommended that diclofenac powder be used for the preparation of suspensions. For pediatric use, palatability is a consideration, and a masking agent should be added before administration. An expiry date of up to

  19. Community Net Energy Metering: How Novel Policies Expand Benefits of Net Metering to Non-Generators

    Energy Technology Data Exchange (ETDEWEB)

    Rose, James; Varnado, Laurel

    2009-04-01

    As interest in community solutions to renewable energy grows, more states are beginning to develop policies that encourage properties with more than one meter to install shared renewable energy systems. State net metering policies are evolving to allow the aggregation of multiple meters on a customer’s property and to dissolve conventional geographical boundaries. This trend means net metering is expanding out of its traditional function as an enabling incentive to offset onsite customer load at a single facility. This paper analyzes community net energy metering (CNEM) as an emerging vehicle by which farmers, neighborhoods, and municipalities may more easily finance and reap the benefits of renewable energy. Specifically, it aims to compare and contrast the definition of geographical boundaries among different CNEM models and examine the benefits and limitations of each approach. As state policies begin to stretch the geographic boundaries of net metering, they allow inventive solutions to encourage renewable energy investment. This paper attempts to initiate the conversation on this emerging policy mechanism and offers recommendations for further development of these policies.

  20. Fuel cell membrane hydration and fluid metering

    Science.gov (United States)

    Jones, Daniel O.; Walsh, Michael M.

    1999-01-01

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel in order to mix its respective portion of liquid water with the corresponding portion of the stream. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  1. Energy Theft in the Advanced Metering Infrastructure

    Science.gov (United States)

    McLaughlin, Stephen; Podkuiko, Dmitry; McDaniel, Patrick

    Global energy generation and delivery systems are transitioning to a new computerized "smart grid". One of the principle components of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters with computerized systems that report usage over digital communication interfaces, e.g., phone lines. However, with this infrastructure comes new risk. In this paper, we consider adversary means of defrauding the electrical grid by manipulating AMI systems. We document the methods adversaries will use to attempt to manipulate energy usage data, and validate the viability of these attacks by performing penetration testing on commodity devices. Through these activities, we demonstrate that not only is theft still possible in AMI systems, but that current AMI devices introduce a myriad of new vectors for achieving it.

  2. Analysis Balance Parameter of Optimal Ramp metering

    Science.gov (United States)

    Li, Y.; Duan, N.; Yang, X.

    2018-05-01

    Ramp metering is a motorway control method to avoid onset congestion through limiting the access of ramp inflows into the main road of the motorway. The optimization model of ramp metering is developed based upon cell transmission model (CTM). With the piecewise linear structure of CTM, the corresponding motorway traffic optimization problem can be formulated as a linear programming (LP) problem. It is known that LP problem can be solved by established solution algorithms such as SIMPLEX or interior-point methods for the global optimal solution. The commercial software (CPLEX) is adopted in this study to solve the LP problem within reasonable computational time. The concept is illustrated through a case study of the United Kingdom M25 Motorway. The optimal solution provides useful insights and guidances on how to manage motorway traffic in order to maximize the corresponding efficiency.

  3. Quality control of the activity meter

    International Nuclear Information System (INIS)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  4. From Smart Metering to Smart Grid

    Science.gov (United States)

    Kukuča, Peter; Chrapčiak, Igor

    2016-06-01

    The paper deals with evaluation of measurements in electrical distribution systems aimed at better use of data provided by Smart Metering systems. The influence of individual components of apparent power on the power loss is calculated and results of measurements under real conditions are presented. The significance of difference between the traditional and the complex evaluation of the electricity consumption efficiency by means of different definitions of the power factor is illustrated.

  5. Wanted: competitive metering infrastructure. Metering must be automated in a high grade; Gesucht: wettbewerbsfaehige Metering-Infrastruktur. Metering muss hochgradig automatisiert werden

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Elschner, C. [T-Systems Enterprise Services GmbH, Bonn (Germany). Business Development und Marketing

    2008-04-21

    Accurate on-time consumption metering and data transmission are increasingly important as energy markets are being deregulated. Measuring and information systems combine measurements with intelligent modules for automatic transmission of consumption information. A meaningful cost-benefit comparision results only when the total system is considered. Telecommunication companies as ICT service systems and service sectors can do a clear contribution to the total system. (orig./GL)

  6. Device Stores and Discharges Metered Fluid

    Science.gov (United States)

    Hooper, S. L.; Setzer, D.

    1983-01-01

    Hand-held container accepts measured amount of liquid from pressurized supply. Supply pressure drives spring-loaded piston that stores enough mechanical energy to discharge measured liquid into another container. Original application of container was to rehydrate sterilized pre-packaged food in zerogravity environment of space vehicles. Possible terrestrial applicatios include dispensing of toxic fluids or metering of fluids for household, commercial or laboratory uses.

  7. Clogging in constricted suspension flows

    Science.gov (United States)

    Marin, Alvaro; Lhuissier, Henri; Rossi, Massimiliano; Kähler, Christian J.

    2018-02-01

    The flow of a charged-stabilized suspension through a single constricted channel is studied experimentally by tracking the particles individually. Surprisingly, the behavior is found to be qualitatively similar to that of inertial dry granular systems: For small values of the neck-to-particle size ratio (D /d reported for granular systems and agree for moderate particle volume fraction (ϕ ≈20 % ) with a simple stochastic model for the number of particles at the neck. For larger neck sizes (D /d >3 ), even at the largest ϕ (≈60 %) achievable in the experiments, an uninterrupted particle flow is observed, which resembles that of an hourglass. This particularly small value of D /d (≃3 ) at the transition to a practically uninterrupted flow is attributed to the low effective friction between the particles, achieved by the particle's functionalization and lubrication.

  8. Next Generation Suspension Dynamics Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Schunk, Peter Randall [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Higdon, Jonathon [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Chen, Steven [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-12-01

    This research project has the objective to extend the range of application, improve the efficiency and conduct simulations with the Fast Lubrication Dynamics (FLD) algorithm for concentrated particle suspensions in a Newtonian fluid solvent. The research involves a combination of mathematical development, new computational algorithms, and application to processing flows of relevance in materials processing. The mathematical developments clarify the underlying theory, facilitate verification against classic monographs in the field and provide the framework for a novel parallel implementation optimized for an OpenMP shared memory environment. The project considered application to consolidation flows of major interest in high throughput materials processing and identified hitherto unforeseen challenges in the use of FLD in these applications. Extensions to the algorithm have been developed to improve its accuracy in these applications.

  9. Solid lipid nanoparticle suspension enhanced the therapeutic efficacy of praziquantel against tapeworm

    Directory of Open Access Journals (Sweden)

    Xie S

    2011-10-01

    Full Text Available Shuyu Xie1,*, Baoliang Pan1,*, Baoxin Shi2, Zhuangzhi Zhang2, Xu Zhang2, Ming Wang1, Wenzhong Zhou11Department of Preventive Veterinary Medicine, College of Veterinary Medicine, China Agricultural University, Beijing, People’s Republic of China; 2Veterinary Research Institute, Xinjiang Academy of Animal Science, Xinjiang, People’s Republic of China *These authors contributed equally to this study Abstract: Hydatid disease caused by tapeworm is an increasing public health and socioeconomic concern. In order to enhance the therapeutic efficacy of praziquantel (PZQ against tapeworm, PZQ-loaded hydrogenated castor oil solid lipid nanoparticle (PZQ-HCO-SLN suspension was prepared by a hot homogenization and ultrasonication method. The stability of the suspension at 4°C and room temperature was evaluated by the physicochemical characteristics of the nanoparticles and in-vitro release pattern of the suspension. Pharmacokinetics was studied after subcutaneous administration of the suspension in dogs. The therapeutic effect of the novel formulation was evaluated in dogs naturally infected with Echinococcus granulosus. The results showed that the drug recovery of the suspension was 97.59% ± 7.56%. Nanoparticle diameter, polydispersivity index, and zeta potential were 263.00 ± 11.15 nm, 0.34 ± 0.06, and -11.57 ± 1.12 mV, respectively and showed no significant changes after 4 months of storage at both 4°C and room temperature. The stored suspensions displayed similar in-vitro release patterns as that of the newly prepared one. SLNs increased the bioavailability of PZQ 5.67-fold and extended the mean residence time of the drug from 56.71 to 280.38 hours. Single subcutaneous administration of PZQ-HCO-SLN suspension obtained enhanced therapeutic efficacy against tapeworm in infected dogs. At the dose of 5 mg/kg, the stool-ova reduction and negative conversion rates and tapeworm removal rate of the suspension were 100%, while the native PZQ were 91

  10. Electricity Consumption Clustering Using Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Alexander Tureczek

    2018-04-01

    Full Text Available Electricity smart meter consumption data is enabling utilities to analyze consumption information at unprecedented granularity. Much focus has been directed towards consumption clustering for diversifying tariffs; through modern clustering methods, cluster analyses have been performed. However, the clusters developed exhibit a large variation with resulting shadow clusters, making it impossible to truly identify the individual clusters. Using clearly defined dwelling types, this paper will present methods to improve clustering by harvesting inherent structure from the smart meter data. This paper clusters domestic electricity consumption using smart meter data from the Danish city of Esbjerg. Methods from time series analysis and wavelets are applied to enable the K-Means clustering method to account for autocorrelation in data and thereby improve the clustering performance. The results show the importance of data knowledge and we identify sub-clusters of consumption within the dwelling types and enable K-Means to produce satisfactory clustering by accounting for a temporal component. Furthermore our study shows that careful preprocessing of the data to account for intrinsic structure enables better clustering performance by the K-Means method.

  11. The Gemini 8-Meter Telescopes Project

    Science.gov (United States)

    Boroson, Todd A.

    1995-05-01

    The Gemini 8-Meter Telescopes Project is an international partnership to build and operate two 8-meter telescopes, one on Mauna Kea, Hawaii, and one on Cerro Pachon, Chile. The telescopes will be international facilities, open to the scientific communities of the six member countries, the United States (50%), the United Kingdom (25%), Canada (15%), Chile (5%), Argentina (2.5%), and Brazil (2.5%). The telescopes are designed to exploit the best atmospheric conditions at these excellent sites. Near diffraction limited performance will be delivered at 2.2 microns and longward, with minimal degradation of the best seeing conditions at shorter wavelengths. The telescopes and facilities are designed to achieve emissivity opportunity. First light for the Mauna Kea telescope is expected in late 1998, and for the Cerro Pachon telescope in mid-2000. This talk will report on construction progress, the instrumental capabilities, and operations strategies being considered. The Gemini 8-meter Telescopes Project is managed by the Association of Universities for Research in Astronomy (AURA), Inc. under a cooperative agreement with the National Science Foundation which serves as executive agency for the Gemini partner countries. U.S. participation in the project is through the U.S. Gemini Program, a division of the National Optical Astronomy Observatories. NOAO is operated by AURA, Inc. under cooperative agreement with the National Science Foundation.

  12. Route Optimization for Offloading Congested Meter Fixes

    Science.gov (United States)

    Xue, Min; Zelinski, Shannon

    2016-01-01

    The Optimized Route Capability (ORC) concept proposed by the FAA facilitates traffic managers to identify and resolve arrival flight delays caused by bottlenecks formed at arrival meter fixes when there exists imbalance between arrival fixes and runways. ORC makes use of the prediction capability of existing automation tools, monitors the traffic delays based on these predictions, and searches the best reroutes upstream of the meter fixes based on the predictions and estimated arrival schedules when delays are over a predefined threshold. Initial implementation and evaluation of the ORC concept considered only reroutes available at the time arrival congestion was first predicted. This work extends previous work by introducing an additional dimension in reroute options such that ORC can find the best time to reroute and overcome the 'firstcome- first-reroute' phenomenon. To deal with the enlarged reroute solution space, a genetic algorithm was developed to solve this problem. Experiments were conducted using the same traffic scenario used in previous work, when an arrival rush was created for one of the four arrival meter fixes at George Bush Intercontinental Houston Airport. Results showed the new approach further improved delay savings. The suggested route changes from the new approach were on average 30 minutes later than those using other approaches, and fewer numbers of reroutes were required. Fewer numbers of reroutes reduce operational complexity and later reroutes help decision makers deal with uncertain situations.

  13. Graphite suspension in carbon dioxide

    International Nuclear Information System (INIS)

    Roche, R.

    1965-01-01

    Since 1963 the Atomic Division of SNECMA has been conducting, under a contract with the CEA, an experimental work with a two-component fluid comprised of carbon dioxide and small graphite particles. The primary purpose was the determination of basic engineering information pertaining to the stability and the flowability of the suspension. The final form of the experimental loop consists mainly of the following items: a light-phase compressor, a heavy-phase pump, an electrical-resistance type heater section, a cooling heat exchanger, a hairpin loop, a transparent test section and a separator. During the course of the testing, it was observed that the fluid could be circulated quite easily in a broad range of variation of the suspension density and velocity - density from 30 to 170 kg/m 3 and velocity from 2 to 24 m/s. The system could be restarted and circulation maintained without any difficulty, even with the heavy-phase pump alone. The graphite did not have a tendency to pack or agglomerate during operation. No graphite deposition was observed on the wall of the tubing. A long period run (250 hours) has shown the evolution of the particle dimensions. Starting with graphite of surface area around 20 m 2 /g (graphite particles about 1 μ), the powder surface area reaches an asymptotic value of 300 m 2 /g (all the particles less than 0.3 μ). Moisture effect on flow stability, flow distribution between two parallel channels, pressure drop in straight tubes, recompression ratio in diffusers were also investigated. (author) [fr

  14. Naratriptan hydrochloride in extemporaneosly compounded oral suspensions.

    Science.gov (United States)

    Zhang, Y P; Trissel, L A; Fox, J L

    2000-01-01

    The purpose of this study was to determine the pharmaceutical acceptability and chemical stability of naratriptan hydrochloride in three extemporaneously compounded suspension formulations. The naratriptan-hydrochloride oral suspensions were prepared from 2.5-mg commercial tablets yielding a nominal naratriptan concentration of 0.5 mg/mL. The suspension vehicles selected for testing were Syrpalta, an equal-parts mixture of Ora-Plus and Ora-Sweet, and an equal-parts mixture of Ora-Plus and Ora-Sweet SF. The tablets were crushed and thoroughly triturated to a fine powder using a porcelain mortar and pestle. The powder was incorporated into a portion of the Syrpalta or Ora-Plus suspension vehicle and mixed until homogeneous. The mixtures were then brought to volume with Syrpalta, Ora-Sweet or Ora-Sweet SF, as appropriate. The suspensions were packaged in amber, plastic, screw-cap prescription bottles and stored at 23 deg C for seven days and 4 deg C for 90 days. An adequate suspension was never achieved in Syrpalta. The crushed-tablet powder did not produce a uniformly dispersed mixture and exhibited clumping and a high rate of sedimentation. A distinct layer of the solid tablet material settled immediately after shaking. Over the next four hours, a densely packed, yellow, caked layer formed at the bottom of the containers, making resuspension difficult. During storage, the caking became worse. Chemical analysis was not performed. The Ora-Plus and Ora-Sweet or Ora-Sweet SF suspensions had a slight greenish cast and were resuspended without difficulty by shaking for approximately ten seconds, yielding easily poured and homogeneous mixtures throughout the study. Visible settling and layering did not begin for four hours with the Ora-Sweet suspension and 24 hours for the Ora-Sweet SF suspension. High pressure liquid chromatographic analysis found that the naratriptan concentration in both suspension-vehicle combinations exhibited little or no loss for seven days at 23

  15. Usefulness of oral loading of oxcarbazepine suspension in selected patients with epilepsy.

    Science.gov (United States)

    Kim, Dong Wook; Gu, Namyi; Lee, Howard; Jang, In-Jin; Chu, Kon; Yu, Kyung-Sang; Cho, Joo-Youn; Yoon, Seo Hyun; Na, Hyun Jeong; Lee, Sang Kun

    2013-10-01

    Oral loading of oxcarbazepine tablet is effective and well tolerated to adequately achieve the therapeutic levels of its active metabolite, 10,11-dihydro-10-hydroxy-carbazepine (monohydroxy derivative, MHD) in epilepsy patients. The present study was performed to investigate the safety, tolerability, and pharmacokinetic profiles of oral loading of oxcarbazepine suspension in epilepsy patients with a high risk of recurrent seizures. Oxcarbazepine suspension was administered orally at a single loading dose of 30 mg/kg to 38 adult patients with recurrent seizures, who required rapid seizure control or temporarily discontinued antiepileptic drugs for diagnostic or pre-surgical evaluation. Plasma concentrations of oxcarbazepine and MHD were determined, and adverse events were assessed at 2, 4, 6, 8, 10, 12, 14, 16, and 24 hours after oral loading of oxcarbazepine suspension. 30 patients experienced ≥ 1 adverse event during the first 24 hours after oral loading of oxcarbazepine (e.g., dizziness, transient diplopia, nausea or vomiting), most of which occurred within 4 hours after loading, suggesting no temporal association with MHD plasma levels. 35 (92.1%) patients were still compliant with a maintenance dose of oxcarbazepine after discharge from hospital. 34 (89.4%) patients reached the lower therapeutic level of MHD (12 mg/l) at 4 hours after oral loading of oxcarbazepine suspension, which lasted up to 24 hours in most patients. No patient reached the supratherapeutic levels of MHD (> 35 mg/l) during the study. The mean plasma concentration-time curves and pharmacokinetic profiles of oral loading of oxcarbazepine suspension were similar to those of oral loading of oxcarbazepine tablet. Oral loading of oxcarbazepine suspension followed by maintenance dosing is well tolerated and effective in steadily achieving the therapeutic level of MHD in selected patients with epilepsy.

  16. Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery.

    Science.gov (United States)

    Karon, Brad S; Meeusen, Jeffrey W; Bryant, Sandra C

    2015-08-25

    We retrospectively studied the impact of glucose meter error on the efficacy of glycemic control after cardiovascular surgery. Adult patients undergoing intravenous insulin glycemic control therapy after cardiovascular surgery, with 12-24 consecutive glucose meter measurements used to make insulin dosing decisions, had glucose values analyzed to determine glycemic variability by both standard deviation (SD) and continuous overall net glycemic action (CONGA), and percentage glucose values in target glucose range (110-150 mg/dL). Information was recorded for 70 patients during each of 2 periods, with different glucose meters used to measure glucose and dose insulin during each period but no other changes to the glycemic control protocol. Accuracy and precision of each meter were also compared using whole blood specimens from ICU patients. Glucose meter 1 (GM1) had median bias of 11 mg/dL compared to a laboratory reference method, while glucose meter 2 (GM2) had a median bias of 1 mg/dL. GM1 and GM2 differed little in precision (CV = 2.0% and 2.7%, respectively). Compared to the period when GM1 was used to make insulin dosing decisions, patients whose insulin dose was managed by GM2 demonstrated reduced glycemic variability as measured by both SD (13.7 vs 21.6 mg/dL, P meter error (bias) was associated with decreased glycemic variability and increased percentage of values in target glucose range for patients placed on intravenous insulin therapy following cardiovascular surgery. © 2015 Diabetes Technology Society.

  17. Self-powered suspension criterion and energy regeneration implementation scheme of motor-driven active suspension

    Science.gov (United States)

    Yan, Shuai; Sun, Weichao

    2017-09-01

    Active suspension systems have advantages on mitigating the effects of vehicle vibration caused by road roughness, which are one of the most important component parts in influencing the performances of vehicles. However, high amount of energy consumption restricts the application of active suspension systems. From the point of energy saving, this paper presents a self-powered criterion of the active suspension system to judge whether a motor-driven suspension can be self-powered or not, and then a motor parameter condition is developed as a reference to design a self-powered suspension. An energy regeneration implementation scheme is subsequently proposed to make the active suspension which has the potential to be self-powered achieve energy-saving target in the real application. In this implementation scheme, operating electric circuits are designed based on different working status of the actuator and power source and it is realizable to accumulate energy from road vibration and supply energy to the actuator by switching corresponding electric circuits. To apply the self-powered suspension criterion and energy regeneration implementation scheme, an active suspension system is designed with a constrained H∞ controller and calculation results indicate that it has the capability to be self-powered. Simulation results show that the performances of the self-powered active suspension are nearly the same as those of the active suspension with an external energy source and can achieve energy regeneration at the same time.

  18. Characterization of cell suspensions from solid tumors

    International Nuclear Information System (INIS)

    Pallavicini, M.

    1985-01-01

    The desirable features of cells in suspension will necessarily be dependent upon the use for which the cells were prepared. Adequate cell yield or recovery is defined by the measurement to be performed. Retention of cellular morphology is important for microscopic identification of cell types in a heterogenous cell suspension, and may be used to determine whether the cells in suspension are representative of those in the tumor in situ. Different dispersal protocols may yield cells with different degrees of clonogenicity, as well as altered biochemical features, such as loss of cellular proteins, surface antigens, nucleotide pools, etc. The quality of the cell suspension can be judged by the degree of cell clumping and level of cellular debris, both of which impact on flow cytometric measurements and studies in which the number of cells be known accurately. Finally, if the data measured on the cells in suspension are to be extrapolated to phenomena occurring in the tumor in situ, it is desirable that the cells in suspension are representative of those in the solid tumor in vivo. This report compares characteristics of tumor cell suspensions obtained by different types of selected disaggregation methods. 33 refs., 2 figs., 4 tabs

  19. Effect of previous irradiation of mineral powders on stability of suspensions

    International Nuclear Information System (INIS)

    Kazaryan, G.A.; Polushkin, V.A.; Vlasov, A.V.; Tsetlin, B.L.; Chakhoyan, P.A.; TsNII Khlopchatobumazhnoj Promyshlennosti, Moscow)

    1984-01-01

    One has investigated the influence of the previous irradiation (X-rays and gamma rays) in the viscosity and the aggregative stability of the suspensions of mineral powders (e. g. kaolin, MgO, TiO 2 ) in a number of organic liquids. It has been shown that when the powders have been irradiated at a dose of the order of 10 to 100 Gy, a considerable increase in the stability of suspensions in polar organic liquids is observed. The detected phenomenon is attributed to the formation of additional, positively charged centres on the surface of the particles of mineral substances under the effect of irradiation

  20. Stability of compounded trilostane suspension in cod liver oil.

    Science.gov (United States)

    Crosby, Jesse; Brown, Stacy

    2017-10-01

    Trilostane is a synthetic steroid analog used to treat canine hyperadrenocorticism. For small dogs, the dose found in commercially available dosage forms of trilostane is sometimes too high. Compounding trilostane in a liquid diluent provides an option for more precise dosing and adjustments, and can be easier to administer, versus a tablet or capsule. Trilostane suspends well in cod liver oil, which is generally palatable to dogs. The stability of a compounded trilostane suspension in cod liver oil stored at room temperature was investigated for 90 days. Compounded trilostane retained stability, defined as maintaining 90-105% labeled value, for 60 days when stored in amber glass bottles. However, drug potency fell >10% below the labeled value when stored in amber plastic bottles after 7 days. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  2. Real time Aanderaa current meter data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    AshokKumar, K.; Diwan, S.G.

    Aanderaa current meters are widely used for recording the current speed and such other 4 parameters by deploying them over extended period of time. Normally data are recorded on magnetic tape and after recovery of current meters, data are read...

  3. External dose distributions of exposure to natural uranium slab for calibration of beta absorbed dose

    International Nuclear Information System (INIS)

    Chen Lishu

    1987-01-01

    The depth dose distributions and uniformity of beta radiation fields from a natural uranium slab in equilibration were measured using a tissue equivalent extrapolation chamber and film dosimeter. The advantages for calibration of enviromental dose instument or survey meter and personal dosimeter, for routine monitoring in terms of directional dose equivalent and superficial individual dose equivalent were summarized. Finally, the values measured agree well with that of theoretical calculation

  4. External dose distributions of exposure to natural uranium slab for calibration of beta absorbed dose

    Energy Technology Data Exchange (ETDEWEB)

    Lishu, Chen

    1987-05-01

    The depth dose distributions and uniformity of beta radiation fields from a natural uranium slab in equilibration were measured using a tissue equivalent extrapolation chamber and film dosimeter. The advantages for calibration of enviromental dose instument or survey meter and personal dosimeter, for routine monitoring in terms of directional dose equivalent and superficial individual dose equivalent were summarized. Finally, the values measured agree well with that of theoretical calculation.

  5. Vehicle lateral dynamics stabilization using active suspension

    Directory of Open Access Journals (Sweden)

    Drobný V.

    2008-12-01

    Full Text Available The paper deals with the investigation of active nonlinear suspension control in order to stabilize the lateral vehicle motion in similar way as systems like ESP do. The lateral stabilization of vehicle based on braking forces can be alternatively provided by the different setting of suspension forces. The basis of this control is the nonlinear property of the tyres. The vehicle has at least four wheels and it gives one or more redundant vertical forces that can be used for the different distribution of vertical suspension forces in such a way that resulting lateral and/or longitudinal forces create the required correction moment for lateral dynamic vehicle stabilization.

  6. Suspension for the low frequency facility

    CERN Document Server

    Cella, G; Di Virgilio, A; Gaddi, A; Viceré, A

    2000-01-01

    We introduce the working principles of the VIRGO Low Frequency Facility (LFF), whose main aim is the measurement of the thermal noise in the VIRGO suspension system. We evaluate the displacement thermal noise of a mirror, which is an intermediate element of a double pendulum suspension system. This double pendulum will be suspended to the last stage of a VIRGO Super-Attenuator (SA), the prototype VIRGO suspension system being tested at the Pisa section of INFN. In the proposed configuration, we evaluate the spectrum of the thermal noise for different choices of the parameters: based on this study, we comment on the future directions to be undertaken in the LFF experiment.

  7. IMAGE TYPE WATER METER CHARACTER RECOGNITION BASED ON EMBEDDED DSP

    OpenAIRE

    LIU Ying; HAN Yan-bin; ZHANG Yu-lin

    2015-01-01

    In the paper, we combined DSP processor with image processing algorithm and studied the method of water meter character recognition. We collected water meter image through camera at a fixed angle, and the projection method is used to recognize those digital images. The experiment results show that the method can recognize the meter characters accurately and artificial meter reading is replaced by automatic digital recognition, which improves working efficiency.

  8. 49 CFR 192.357 - Customer meters and regulators: Installation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  9. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  10. 24 CFR 965.401 - Individually metered utilities.

    Science.gov (United States)

    2010-04-01

    ... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Individual Metering of Utilities for Existing PHA-Owned Projects § 965.401 Individually metered utilities. (a) All utility service shall be... supplier or through the use of checkmeters, unless: (1) Individual metering is impractical, such as in the...

  11. Integrating an embedded system in a microwave moisture meter

    Science.gov (United States)

    The conversion of a PC- or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter measures the attenuation and phase shift of low power microwaves traversing the sample, from which the dielectric properties are calculated. T...

  12. Integrating an Embedded System within a Microwave Moisture Meter

    Science.gov (United States)

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter uses low-power microwaves to measure the attenuation and phase shift of the sample, from which the dielectric properties are cal...

  13. HJD-I record and analysis meter for nuclear information

    International Nuclear Information System (INIS)

    Di Shaoliang; Huang Yong; Xiao Yanbin

    1992-01-01

    A low-cost, small-volume, multi-function and new model intelligent nuclear electronic meter HJD-I Record and Analysis Meter are stated for Nuclear Information. It's hardware and software were detailed and the 137 Cs spectrum with this meter was presented

  14. A Scalable Smart Meter Data Generator Using Spark

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Danalachi, Sergiu

    2017-01-01

    Today, smart meters are being used worldwide. As a matter of fact smart meters produce large volumes of data. Thus, it is important for smart meter data management and analytics systems to process petabytes of data. Benchmarking and testing of these systems require scalable data, however, it can ...

  15. The disc pasture meter: Possible applications in grazing management.

    African Journals Online (AJOL)

    The disc meter is a simple inexpensive instrument which may be used to make rapid yield estimates of standing forage. Linear regression relationships between meter reading and pasture dry matter yield are usually fairly good, but these may be affected by a number of different factors. The meter should therefore be ...

  16. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  17. Multichannel Distribution Meter: A Veritable Solution in Power ...

    African Journals Online (AJOL)

    Partitioned apartments in commercial buildings particularly in congested environments shares energy supply meters among several users. This often leads to disputes and results to power theft in the form of unpaid bills and meter tampering. This paper described how power from a single supply meter can be adequately ...

  18. Calibration and evaluation of neutron survey meters used at linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, A.P. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Fonseca, E.S. da; Patrao, K.C.S. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Batista, D.V.S. [Instituto Nacional do Cancer - INCa, Praca Cruz Vermelha, 23 - centro, CEP 20230-130 Rio de Janeiro (Brazil)

    2010-12-15

    Calibrated survey meters from the Neutron Laboratory of the Instituto de Radioprotecao e Dosimetria (IRD) were used to determine the ambient dose-equivalent rate in a 15 MV linear accelerator treatment room at the Instituto Nacional do Cancer (INCa). Three different models of neutron survey meters were calibrated using four neutron radionuclide neutron sources: {sup 241}AmBe({alpha},n), {sup 252}Cf(f,n), heavy-water moderated {sup 252}Cf(f,n), and {sup 238}PuBe({alpha},n). All neutron sources were standardized in a Manganese Sulphate Bath (MSB) absolute primary system. The response of each of these instruments was compared with reference values of ambient dose-equivalent rate. The results demonstrate the complexity of making measurements in the mixed neutron/photon field produced in electron linear accelerator radiotherapy treatment rooms.

  19. Investigating high-concentration monoclonal antibody powder suspension in nonaqueous suspension vehicles for subcutaneous injection.

    Science.gov (United States)

    Bowen, Mayumi; Armstrong, Nick; Maa, Yuh-Fun

    2012-12-01

    Developing high-concentration monoclonal antibody (mAb) liquid formulations for subcutaneous (s.c.) administration is challenging because increased viscosity makes injection difficult. To overcome this obstacle, we investigated a nonaqueous powder suspension approach. Three IgG1 mAbs were spray dried and suspended at different concentrations in Miglyol® 840, benzyl benzoate, or ethyl lactate. Suspensions were characterized for viscosity, particle size, and syringeability; physical stability was visually inspected. Suspensions generally outperformed liquid solutions for injectability despite higher viscosity at the same mAb concentrations. Powder formulations and properties had little effect on viscosity or injectability. Ethyl lactate suspensions had lowest viscosity (Miglyol® 840 improved overall performance in high mAb concentration suspensions. This study demonstrated the viability of high mAb concentration (>300 mg/mL) in suspension formulations for s.c. administration. Copyright © 2012 Wiley Periodicals, Inc.

  20. NUCLEAR MIXING METERS FOR CLASSICAL NOVAE

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Keegan J.; Iliadis, Christian; Downen, Lori; Champagne, Art [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); José, Jordi [Departament de Física i Enginyeria Nuclear, EUETIB, Universitat Politècnica de Catalunya, E-08036 Barcelona (Spain)

    2013-11-10

    Classical novae are caused by mass transfer episodes from a main-sequence star onto a white dwarf via Roche lobe overflow. This material possesses angular momentum and forms an accretion disk around the white dwarf. Ultimately, a fraction of this material spirals in and piles up on the white dwarf surface under electron-degenerate conditions. The subsequently occurring thermonuclear runaway reaches hundreds of megakelvin and explosively ejects matter into the interstellar medium. The exact peak temperature strongly depends on the underlying white dwarf mass, the accreted mass and metallicity, and the initial white dwarf luminosity. Observations of elemental abundance enrichments in these classical nova events imply that the ejected matter consists not only of processed solar material from the main-sequence partner but also of material from the outer layers of the underlying white dwarf. This indicates that white dwarf and accreted matter mix prior to the thermonuclear runaway. The processes by which this mixing occurs require further investigation to be understood. In this work, we analyze elemental abundances ejected from hydrodynamic nova models in search of elemental abundance ratios that are useful indicators of the total amount of mixing. We identify the abundance ratios ΣCNO/H, Ne/H, Mg/H, Al/H, and Si/H as useful mixing meters in ONe novae. The impact of thermonuclear reaction rate uncertainties on the mixing meters is investigated using Monte Carlo post-processing network calculations with temperature-density evolutions of all mass zones computed by the hydrodynamic models. We find that the current uncertainties in the {sup 30}P(p, γ){sup 31}S rate influence the Si/H abundance ratio, but overall the mixing meters found here are robust against nuclear physics uncertainties. A comparison of our results with observations of ONe novae provides strong constraints for classical nova models.

  1. Digital radioisotope moisture-density meter

    International Nuclear Information System (INIS)

    Bychvarov, N.; Vankov, I.; Dimitrov, L.

    1982-01-01

    The primary information from the detectors of a combined radioisotope moisture-density meter is obtained as pulses, their counting rate being functionally dependent on the humidity per unit volume and the wet density. However, most practical cases demand information on the moisture per unit weight and the mass density of the dry skeleton. The paper describes how the proposed electronic circuit processes the input primary information to obtain the moisture in weight % and the mass density of the dry skeleton in g/cm 3 . (authors)

  2. Ramp - Metering Algorithms Evaluated within Simplified Conditions

    Science.gov (United States)

    Janota, Aleš; Holečko, Peter; Gregor, Michal; Hruboš, Marián

    2017-12-01

    Freeway networks reach their limits, since it is usually impossible to increase traffic volumes by indefinitely extending transport infrastructure through adding new traffic lanes. One of the possible solutions is to use advanced intelligent transport systems, particularly ramp metering systems. The paper shows how two particular algorithms of local and traffic-responsive control (Zone, ALINEA) can be adapted to simplified conditions corresponding to Slovak freeways. Both control strategies are modelled and simulated using PTV Vissim software, including the module VisVAP. Presented results demonstrate the properties of both control strategies, which are compared mutually as well as with the initial situation in which no control strategy is applied

  3. Ramp - Metering Algorithms Evaluated within Simplified Conditions

    Directory of Open Access Journals (Sweden)

    Janota Aleš

    2017-12-01

    Full Text Available Freeway networks reach their limits, since it is usually impossible to increase traffic volumes by indefinitely extending transport infrastructure through adding new traffic lanes. One of the possible solutions is to use advanced intelligent transport systems, particularly ramp metering systems. The paper shows how two particular algorithms of local and traffic-responsive control (Zone, ALINEA can be adapted to simplified conditions corresponding to Slovak freeways. Both control strategies are modelled and simulated using PTV Vissim software, including the module VisVAP. Presented results demonstrate the properties of both control strategies, which are compared mutually as well as with the initial situation in which no control strategy is applied

  4. Victoreen panoramic 470 A survey meter

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-07-01

    This instrument is a portable, battery powered, survey meter covering an exposure rate range from 0 to 1000 R h -1 . and an exposure range of 0 to 1000 mR. It is designed to measure X- and γ-radiation over a wide range of energies and angular distributions, and also to detect alpha and beta radiation. The radiation detector is an unsealed ionisation chamber. The report describes the instrument under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  5. Dynamic range meter for radiofrequency amplifiers

    Directory of Open Access Journals (Sweden)

    Drozd S. S.

    2009-04-01

    Full Text Available The new measurement setup having increased on 20…30 dB the own dynamic range in comparison with the standard circuit of the dynamic range meter is offered and the rated value of an error bringing by setup in the worst case does not exceed ± 2,8 dB. The measurement setup can be applied also to determinate levels of intermodulation components average power amplifiers and powerful amplifiers of a low-frequency at replacement of the quartz filter on meeting low-frequency the LC-filter and the spectrum analyzer.

  6. EPA Region 1 - Valley Depth in Meters

    Science.gov (United States)

    Raster of the Depth in meters of EPA-delimited Valleys in Region 1.Valleys (areas that are lower than their neighbors) were extracted from a Digital Elevation Model (USGS, 30m) by finding the local average elevation, subtracting the actual elevation from the average, and selecting areas where the actual elevation was below the average. The landscape was sampled at seven scales (circles of 1, 2, 4, 7, 11, 16, and 22 km radius) to take into account the diversity of valley shapes and sizes. Areas selected in at least four scales were designated as valleys.

  7. A Course in Fluid Mechanics of Suspensions.

    Science.gov (United States)

    Davis, Robert H.

    1989-01-01

    Discusses a course focusing on fluid mechanics and physical chemistry of suspensions. Describes the main themes of the lectures and includes a list of course outlines. Possible textbooks and many journal articles are listed. (YP)

  8. Heat and mass transfer in particulate suspensions

    CERN Document Server

    Michaelides, Efstathios E (Stathis)

    2013-01-01

    Heat and Mass Transfer in Particulate Suspensions is a critical review of the subject of heat and mass transfer related to particulate Suspensions, which include both fluid-particles and fluid-droplet Suspensions. Fundamentals, recent advances and industrial applications are examined. The subject of particulate heat and mass transfer is currently driven by two significant applications: energy transformations –primarily combustion – and heat transfer equipment. The first includes particle and droplet combustion processes in engineering Suspensions as diverse as the Fluidized Bed Reactors (FBR’s) and Internal Combustion Engines (ICE’s). On the heat transfer side, cooling with nanofluids, which include nanoparticles, has attracted a great deal of attention in the last decade both from the fundamental and the applied side and has produced several scientific publications. A monograph that combines the fundamentals of heat transfer with particulates as well as the modern applications of the subject would be...

  9. Experimental Evaluation of Mountain Bike Suspension Systems

    Directory of Open Access Journals (Sweden)

    J. Titlestad

    2003-01-01

    Full Text Available A significant distinction between competitive mountain bikes is whether they have a suspension system. Research studies indicate that a suspension system gives advantages, but it is difficult to quantify the benefits because they depend on so many variables, including the physiology and psychology of the cyclist, the roughness of the track and the design of the suspension system. A laboratory based test rig has been built that allows the number of variables in the system to be reduced and test conditions to be controlled. The test rig simulates regular impacts of the rear wheel with bumps in a rolling road. The physiological variables of oxygen consumption and heart rate were measured, together with speeds and forces at various points in the system. Physiological and mechanical test results both confirm a significant benefit in using a suspension system on the simulated rough track, with oxygen consumption reduced by around 30 % and power transmitted through the pedals reduced by 30 % to 60 %.

  10. Crust formation in drying colloidal suspensions

    KAUST Repository

    Style, R. W.; Peppin, S. S. L.

    2010-01-01

    and the equations of poroelasticity, while the equations of colloid physics govern processes in the suspension. We derive new equations describing this process, including unique boundary conditions coupling the two regions, yielding a moving-boundary model

  11. Synergisms between smart metering and smart grid; Synergien zwischen Smart Metering und Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-04-15

    With the implementation of a smart metering solution, it is not only possible to acquire consumption data for billing but also to acquire relevant data of the distribution grid for grid operation. There is still a wide gap between the actual condition and the target condition. Synergies result from the use of a common infrastructure which takes account both of the requirements of smart metering and of grid operation. An open architecture also enables the future integration of further applications of the fields of smart grid and smart home. (orig.)

  12. Smart Metering. Synergies within medium voltage automation; Synergien durch Smart Metering. Automatisierung auf Mittelspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-11-15

    Transparent interdivisional system solutions are an indispensable and decisive precondition for the optimization of business processes. The implementation of a Smart Metering solution does not only provide data for billing purposes, but also renders important data for network operation. Synergies can be achieved through the use of a common infrastructure which covers both the needs of Smart Metering and network operation. An open architecture of the solution allows for the future integration of further services of the domains Smart Grid and Smart Home. (orig.)

  13. Energy saving by smart metering with consumption feedback; Energieeinsparung durch Smart Metering mit Verbrauchs-Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Patrick [Institut fuer ZukunftsEnergieSysteme (IZES), Saarbruecken (Germany); Friedrich, Malte [Institut fuer Soziologische Meinungsforschung (IsoMe), Berlin (Germany); Kerber-Clasen, Stefan [Institut fuer Sozialforschung und Sozialwirtschaft e.V., Saarbruecken (Germany); Frey, Guenther

    2012-08-15

    While the German legislative, e.g. in the EnWG (Power Industry Act) assumes that electricity consumption metering will contribute to energy conservation in any case, many studies have arrived at a different contribution: Only a combination of consumption metering and direct feedback methods will result in significant energy savings. A recent research project (''Moderne Energiesparsysteme fuer Haushalte'') analysed an energy conservation system of this type. The findings will provide socio-economic insight into the background of successful energy conservation, and they will show how feedback methods can be optimised.

  14. Increasing Possibilities of Nano suspension

    International Nuclear Information System (INIS)

    Sutradhar, K.B.; Khatun, S.; Luna, I.P.

    2013-01-01

    Nowadays, a very large proportion of new drug candidates emerging from drug discovery programmes are water insoluble and thus poorly bioavailable. To avoid this problem, nano technology for drug delivery has gained much interest as a way to improve the solubility problems. Nano refers to particles size range of 1-1000 nm. The reduction of drug particles into the submicron range leads to a significant increase in the dissolution rate and therefore enhances bioavailability. Nanosuspensions are part of nano technology. This interacts with the body at subcellular (i.e., molecular) scales with a high degree of specificity and can be potentially translated into targeted cellular and tissue-specific clinical applications designed to achieve maximal therapeutic efficacy with minimal side effects. Production of drugs as nanosuspensions can be developed for drug delivery systems as an oral formulation and no noral administration. Here, this review describes the methods of pharmaceutical nano suspension production including advantages and disadvantages, potential benefits, characterization tests, and pharmaceutical applications in drug delivery

  15. Suspension scheme for fuel pin

    International Nuclear Information System (INIS)

    Butts, C.E.; Gray, H.C.

    1975-01-01

    A description is presented of a nuclear fuel pin suspension arrangement comprising, in combination, a rod; a first beam member connected to said rod at one end; a plurality of parallel-spaced slidable fuel support plates attached to said first beam member, the longitudinal axis of first beam member being perpendicular to the longitudinal axis of each of said fuel support plates, a first coupling means disposed along the length of the first beam member for permitting slidable fuel support plates parallel movement with respect to the longitudinal axis of said first beam member, a second coupling means located at one end of each of slidable fuel plates for slidably engaging first coupling means of first beam member, a second beam member connected to the other end of each of parallel-spaced slidable fuel support plates and providing an extension, second beam member being provided with a third coupling means disposed along the length of second beam member at one end thereof; and a plurality of fuel pins provided with a fourth coupling means located at one end of each fuel pin for slidably engaging third coupling means of second beam member to permit each fuel pin parallel movement with respect to the longitudinal axis of second beam member. (U.S.)

  16. Characterization of Complex Colloidal Suspensions

    Science.gov (United States)

    Seaman, J. C.; Guerin, M.; Jackson, B. P.; Ranville, J. M.

    2003-04-01

    Surface chemical reactions play a major role in controlling contaminant fate and transport in the subsurface environment. Recent field and laboratory evidence suggests that mobile soil and groundwater colloids may facilitate the migration of sparingly soluble groundwater contaminants. Colloidal suspensions collected in the field or generated in laboratory column experiments tend to be fairly dilute in nature and comprised of relatively small particulates (reserved for studying ideal systems to the characterization of mobile colloids. However, many of these analytical techniques, including total/selective dissolution methods, dynamic light scattering, micro-electrophoresis, streaming potential, and even scanning electron microscopy (SEM), can be biased in of larger size fractions, and therefore, extremely sensitive to sampling, storage, and fractionation artifacts. In addition, surface modifiers such as sorbed oxides or organics can alter particulate appearance, composition, and behavior when compared to synthetic analogues or mineral standards. The current presentation will discuss the limitations and inherent biases associated with a number of analytical characterization techniques that are commonly applied to the study of mobile soil and groundwater colloids, including field flow fractionation (FFF) and acoustic based methods that have only recently become available.

  17. Compressed Air Production Using Vehicle Suspension

    OpenAIRE

    Ninad Arun Malpure; Sanket Nandlal Bhansali

    2015-01-01

    Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are co...

  18. Automatic ranging circuit for a digital panel meter

    International Nuclear Information System (INIS)

    Mueller, T.R.; Ross, H.H.

    1976-01-01

    This invention relates to a range changing circuit that operates in conjunction with a digital panel meter of fixed sensitivity. The circuit decodes the output of the panel meter and uses that information to change the gain of an input amplifier to the panel meter in order to ensure that the maximum number of significant figures is always displayed in the meter. The circuit monitors five conditions in the meter and responds to any of four combinations of these conditions by means of logic elements to carry out the function of the circuit. The system was designed for readout of a fluorescence analyzer for uranium analysis

  19. A convenient calibrator for tritium survey meters

    International Nuclear Information System (INIS)

    Cutler, J.M.; Janmohamed, S.R.; Surette, R.A.; Wood, M.J.

    1993-06-01

    Staff in Ontario Hydro's CANDU nuclear power stations were having difficulty calibrating their tritium-in-air survey meters. Chalk River Laboratories suggested using a standard silica gel collector loaded with tritiated water vapour as a radiation source. The collector is a polyethylene tube with a length of rubber tubing attached to each end. The plastic tube is filled with dry silica gel, and cotton wool is stuffed into each end to retain the gel. To load the source with tritiated vapour, a bubbler containing tritiated water is connected to the collector until the gel is completely pink. The end tubes of the source are then connected to each other to seal the source. To use the source, the rubber tubes are connected to the intake and exhaust fittings of the survey meter to be calibrated. No tritium vapour is released during loading or calibration. This source not only verifies that the ion chamber and electrometer are working, but also checks whether the air sample is reaching the detector. It is more direct and credible than a gamma source, and is inexpensive and convenient to construct and calibrate at the power station. 5 figs

  20. Calibration of ionization chamber survey meter

    International Nuclear Information System (INIS)

    Kadhim, A.K.; Kadni, T.B.

    2016-01-01

    Radiation measuring devices need to process calibration which lose their sensitivity and the extent of the response and the amount of stability under a changing conditions from time to time and this period depends on the nature and use of field in which used devices. A comparison study was done toa (45 I P) ( ionization chamber survey meter) and this showed the variation factor in five different years. This study also displayed the concept of radiation instrument calibration and necessity of every year calibration of them.In this project we used the five years calibration data for ionization chamber survey meter model Inspector (1/C F). the value deviation (∆ %) of Cfs for four years of calibration in comparison of C F for the year 2007 are very high and the device under research is not good to use in field and reliable because the ionization chamber is very sensitive to humidity and must calibrate a year or less, or due ing every two years and must maintain carefully to reduce the discarded effects the measurements.

  1. Smart meter users give a thumbs up

    International Nuclear Information System (INIS)

    Horne, D.

    2007-01-01

    The Ontario Energy Board conducted a pilot study with the support of Hydro Ottawa to better understand how consumers change their electricity consumption behaviour with smart meters and time-of-use (TOU) prices. The project enabled consumers to learn the most cost-effective times to use energy. Results from the Ontario Smart Price Pilot reveal that consumers like to have control over how much and when they use their electricity. Although the savings were only small for some clients involved in the study, they appreciated having their metering bills in greater detail. At the end of the pilot project, participants reduced electricity consumption by 6 per cent. Nearly 90 per cent of the participants paid lower energy bills and nearly 80 per cent indicated they would recommend TOU pricing to their friends because it motivated them to shift some of their electricity use away from peak hours. The average reduction in electricity demand among the two-thirds of participants on critical pricing plans was more than 20 per cent during high demand or critical peak hours in summer. Demand reduction on winter critical peak days was much lower for all participants. 1 fig

  2. Ultrasonic flow-meter test in sodium

    International Nuclear Information System (INIS)

    Ishii, Y.; Uno, O.; Kamei, M.

    1978-01-01

    As a part of the R and D programme for the prototype fast breeder reactor MONJU, an ultrasonic flow-meter (USFM) test is being carried out in sodium in the O-Arai Engineering Center of PNC. Prior to the present test, an in-water test was done at the manufacturer's as a preliminary investigation. The results reported here are the results up to the present. Calibration tests using the actual fluid were conducted on a 12-inch ultrasonic flow-meter with guide rods fabricated for sodium flow measurement. The test conditions in sodium were a temperature of 200 approximately 400 0 C and flow-rates of 0 approximately 6m/s. The main results are: (1) The linearity of output signal was good and accuracy was within 1%; (2) The alternating type of the USFM was much better than the fixed type in temperature change; (3) 2MHz of transducer frequency was better than 3MHz in sodium; (4) The S/N ratio of the ultrasonic signal and the length/diameter effect in a wide range in sodium surpassed the in-water test. (author)

  3. EOS suspension test for the assessment of spinal flexibility in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Hirsch, Caroline; Ilharreborde, Brice; Mazda, Keyvan

    2015-07-01

    The assessment of spinal flexibility is essential for the planning of adolescent idiopathic scoliosis (AIS) surgery. Various radiographic methods have been used but none of them has shown any superiority. The new low-dose stereography system EOS (EOS imaging, Paris, France) captures whole body images in a single scan without vertical distortion. EOS is now used in routine clinical use for AIS follow-up. The aim of this study was to prospectively evaluate the feasibility and the reproducibility of a new suspension test during the EOS imaging for the assessment of spinal flexibility in AIS. Fifty AIS patients scheduled for surgery were prospectively included. For each patient, a standard EOS radiograph was obtained, then a suspension test in the EOS and a classic traction test on the cotrel frame were performed. The examinations were compared in terms of radiation exposure, tolerance, mean traction force, and Cobb angle reduction for each curve. Axial and sagittal reductions during suspension were analyzed on three-dimensional EOS reconstructions. The tolerance of the suspension test was lower than the traction test but it was less operator dependent. Radiation exposure was 7 times lower during the suspension test. Cobb angle reductions achieved in the proximal and main curves by the two tests were similar. The traction test achieved greater reduction of the distal curve. Flexibility in the axial plane and in the sagittal plane was analyzed with the suspension test. The reduction in apical rotation was not correlated with the reduction in Cobb angle. The EOS suspension test can be used for the assessment of spinal flexibility in AIS. It gives a global vision of the deformity with new flexibility indices in the axial and sagittal planes.

  4. Flow-induced structure in colloidal suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Vermant, J [Department of Chemical Engineering, K U Leuven, W de Croylaan 46, B-3001 Leuven (Belgium); Solomon, M J [Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109-2136 (United States)

    2005-02-02

    We review the sequences of structural states that can be induced in colloidal suspensions by the application of flow. Structure formation during flow is strongly affected by the delicate balance among interparticle forces, Brownian motion and hydrodynamic interactions. The resulting non-equilibrium microstructure is in turn a principal determinant of the suspension rheology. Colloidal suspensions with near hard-sphere interactions develop an anisotropic, amorphous structure at low dimensionless shear rates. At high rates, clustering due to strong hydrodynamic forces leads to shear thickening rheology. Application of steady-shear flow to suspensions with repulsive interactions induces a rich sequence of transitions to one-, two-and three-dimensional order. Oscillatory-shear flow generates metastable ordering in suspensions with equilibrium liquid structure. On the other hand, short-range attractive interactions can lead to a fluid-to-gel transition under quiescent suspensions. Application of flow leads to orientation, breakup, densification and spatial reorganization of aggregates. Using a non-Newtonian suspending medium leads to additional possibilities for organization. We examine the extent to which theory and simulation have yielded mechanistic understanding of the microstructural transitions that have been observed. (topical review)

  5. Development of a calibration methodology and tests of kerma area product meters; Desenvolvimento de uma metodologia de calibracao e testes de medidores de produto Kerma-Area

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida

    2013-07-01

    The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient's skin doesn't exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter. (author)

  6. 21 CFR 1301.36 - Suspension or revocation of registration; suspension of registration pending final order...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Suspension or revocation of registration; suspension of registration pending final order; extension of registration pending final order. 1301.36... registration pending final order; extension of registration pending final order. (a) For any registration...

  7. Suspension, a Wake-Up Call: Rural Educators' Attitudes toward Suspension.

    Science.gov (United States)

    Henderson, Joan; Friedland, Billie

    Data from the West Virginia Department of Education reveals that from September 1991 to January 1992, school districts reported 18,915 out-of-school suspensions involving 12,997 students. In 1995, the West Virginia State Legislature enacted the Safe Schools Act, which specifically mandates suspension for no less than 12 consecutive months for…

  8. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  9. Logic elements for reactor period meter

    Science.gov (United States)

    McDowell, William P.; Bobis, James P.

    1976-01-01

    Logic elements are provided for a reactor period meter trip circuit. For one element, first and second inputs are applied to first and second chopper comparators, respectively. The output of each comparator is O if the input applied to it is greater than or equal to a trip level associated with each input and each output is a square wave of frequency f if the input applied to it is less than the associated trip level. The outputs of the comparators are algebraically summed and applied to a bandpass filter tuned to f. For another element, the output of each comparator is applied to a bandpass filter which is tuned to f to give a sine wave of frequency f. The outputs of the filters are multiplied by an analog multiplier whose output is 0 if either input is 0 and a sine wave of frequency 2f if both inputs are a frequency f.

  10. Aperture meter for the Large Hadron Collider

    International Nuclear Information System (INIS)

    Mueller, G.J.; Fuchsberger, K.; Redaelli, S.

    2012-01-01

    The control of the high intensity beams of the CERN Large Hadron Collider (LHC) is particular challenging and requires a good modeling of the machine and monitoring of various machine parameters. During operation it is crucial to ensure a minimal distance between the beam edge and the aperture of sensitive equipment, e.g. the superconducting magnets, which in all cases must be in the shadow of the collimator's that protect the machine. Possible dangerous situations must be detected as soon as possible. In order to provide the operator with information about the current machine bottlenecks an aperture meter application was developed based on the LHC online modeling tool-chain. The calculation of available free aperture takes into account the best available optics and aperture model as well as the relevant beam measurements. This paper describes the design and integration of this application into the control environment and presents results of the usage in daily operation and from validation measurements. (authors)

  11. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  12. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  13. Two laboratory methods for the calibration of GPS speed meters

    International Nuclear Information System (INIS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40–180 km h −1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology. (paper)

  14. A Probabilistic Model of Meter Perception: Simulating Enculturation

    Directory of Open Access Journals (Sweden)

    Bastiaan van der Weij

    2017-05-01

    Full Text Available Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter facilitates prediction of future onsets. Such prediction, we hypothesize, is based on previous exposure to rhythms. As such, predictive coding provides a possible explanation for the way meter perception is shaped by the cultural environment. Based on this hypothesis, we present a probabilistic model of meter perception that uses statistical properties of the relation between rhythm and meter to infer meter from quantized rhythms. We show that our model can successfully predict annotated time signatures from quantized rhythmic patterns derived from folk melodies. Furthermore, we show that by inferring meter, our model improves prediction of the onsets of future events compared to a similar probabilistic model that does not infer meter. Finally, as a proof of concept, we demonstrate how our model can be used in a simulation of enculturation. From the results of this simulation, we derive a class of rhythms that are likely to be interpreted differently by enculturated listeners with different histories of exposure to rhythms.

  15. Proceedings of the 2006 smart metering conference and expo

    International Nuclear Information System (INIS)

    2006-01-01

    Ontario's smart metering program was launched as part of a general demand response management strategy to improve energy conservation in the province. Smart metering will help consumers to control their electricity bills through conservation and demand response, and will allow consumers to better manage their energy consumption and use it more effectively during cheaper, off-peak times of day. Smart metering systems measure how much electricity a customer uses on an hourly basis, and data is transferred daily to local electricity distributors. Toronto Hydro will have close to 200,000 smart meters installed by the end of 2006. By 2010, Toronto will be North America's largest urban centre to have made the full transition to smart metering technology across its entire base. This conference provided an update of Toronto Hydro's smart metering project, as well as details of their demand response program. Presentations were given by a variety of experts in information technology as well as electric power industry leaders North American demand and response metering strategies were reviewed, as well as various initiatives in advanced metering infrastructure (AMI). Security risks associated with smart metering environments were reviewed. An evaluation of the current regulatory environment was presented along with a discussion of smart metering standards and compatibility issues. New metering technologies were presented as well as various associated demand side management tools. Smart metering pilot programs and initiatives were discussed, and best practices in smart metering were evaluated. Twenty-nine presentations were given at the conference, 13 of which have been indexed separately for inclusion in this database. refs., tabs., figs

  16. Radiofrequency energy exposure from the Trilliant smart meter.

    Science.gov (United States)

    Foster, Kenneth R; Tell, Richard A

    2013-08-01

    This paper reviews radiofrequency (RF) field levels produced by electric utility meters equipped with RF transceivers (so-called Smart Meters), focusing on meters from one manufacturer (Trilliant, Redwood City, CA, USA, and Granby, QC, Canada). The RF transmission levels are summarized based on publicly available data submitted to the U.S. Federal Communications Commission supplemented by limited independent measurements. As with other Smart Meters, this meter incorporates a low powered radiofrequency transceiver used for a neighborhood mesh network, in the present case using ZigBee-compliant physical and medium access layers, operating in the 2.45 GHz unlicensed band but with a proprietary network architecture. Simple calculations based on a free space propagation model indicate that peak RF field intensities are in the range of 10 mW m or less at a distance of more than 1-2 m from the meters. However, the duty cycle of transmission from the meters is very low (meter that were consistent with data reported by the vendor to the U.S. Federal Communications Commission. Limited measurements conducted in two houses with the meters were unable to clearly distinguish emissions from the meters from the considerable electromagnetic clutter in the same frequency range from other sources, including Wi-Fi routers and, when it was activated, a microwave oven. These preliminary measurements disclosed the difficulties that would be encountered in characterizing the RF exposures from these meters in homes in the face of background signals from other household devices in the same frequency range. An appendix provides an introduction to Smart Meter technology. The RF transmitters in wireless-equipped Smart Meters operate at similar power levels and in similar frequency ranges as many other digital communications devices in common use, and their exposure levels are very far below U.S. and international exposure limits.

  17. The decommissioning of the KEMA suspension test reactor

    International Nuclear Information System (INIS)

    Spruyt, A.; Peters, D.; Loon, W.M.G.M. van; Boekschoten, H.J.C.; Brugman, H.

    1991-01-01

    In this report the decommissioning of the KEMA Suspension Test Reactor (KSTR) is described. This reactor was a 1 MWth aqueous homo-geneous nuclear reactor in which a suspension of a mixed oxide UO 2 / ThO 2 in light water was circulated in a closed loop through a sphere-shaped core vessel. The reactor, located on KEMA premises, made 150 MW of heat during its critical periods. Dismantling of this reactor, with its many connected subsystems, meant the mastering of activated components which were also contaminated on inner surfaces caused by small fuel deposits (alpha contaminants) and fission products (beta, gamma contaminants). A description is given of the save removal of the fuel, the remote dismantling of systems and components and the disposal of steel scrap and other materials. Important features are the measures to be taken and provisions needed for safe handling, for the reduction of the radiation dose for the working team and the prevention of spreading of activity over the working area and the environment. It has been demonstrated that safe dismantling and disposal of such systems can be achieved. Experience gained at KEMA for the proper dismantling and for safety measures to be taken for workers and the environment can be made available for similar dismantling projects. A cost break-down is included in the report. (author). 22 refs.; 52 figs.; 12 tabs

  18. Monitoring the Inhalation Flow Rate of Nebulized Aerosols Using an Ultrasonic Flow Meter: In Vitro Assessment.

    Science.gov (United States)

    Yang, Michael Y; Chan, Hak-Kim

    2017-06-01

    The measurement of aerosol flow rates without obscuration of the flow is of particular concern with in vivo lung deposition studies, where precise knowledge of aerosol particle size distributions is a necessary requirement for the development of predictive correlations. This study examines the utility of an ultrasonic flow meter for such measurements and determines if a valved system can be attached to the flow meter for sampling exhaled aerosols. The flow rate across a D-30 flow meter was compared with and without nebulization of 0.9% saline aerosols from a PARI LC Sprint nebulizer. Particle size distributions of the nebulized aerosol before and after adding the D-30 flow meter and duckbill valve were measured using a Spraytec laser diffraction system. Finally, the ability of the Thor D-30 to capture a realistic breathing profile was assessed. The mean ± standard error flow rates measured by the D-30 flow meter with and without nebulization were 10.4 ± 0.1 versus 10.4 ± 0.1 L/min, 66.4 ± 0.1 versus 67.2 ± 0.1 L/min, and 89.9 ± 0.1 versus 91.4 ± 0.1 L/min. The D-30 flow meter did not considerably affect the volumetric median diameter (VMD) of the aerosols, while the VMD reduced slightly by 0.65 μm at 10 L/min and 0.69 μm at 72 L/min upon the inclusion of a duckbill valve. Time-weighted average inhalation flow rates measured by D-30 flow meters placed upstream and downstream of the one-way valve agreed well, 31.9 versus 32.6 L/min, respectively. The D-30 flow meter can be used to accurately measure inhalation flow rates of nebulized aerosols without significantly impacting particle size distributions, and one-way duckbill valves can be used to isolate the inhalation portion of a breathing pattern to facilitate collection of exhaled doses.

  19. Numerical study of suspensions of deformable particles.

    Science.gov (United States)

    Brandt, Luca; Rosti, Marco Edoardo

    2017-11-01

    We consider a model non-Newtonian fluid consisting of a suspension of deformable particles in a Newtonian solvent. Einstein showed in his pioneering work that the relative increase in effective viscosity is a linear function of the particle volume fraction for dilute suspensions of rigid particles. Inertia has been shown to introduce deviations from the behaviour predicted by the different empirical fits, an effect that can be related to an increase of the effective volume fraction. We here focus on the effect of elasticity, i.e. visco-elastic deformable particles. To tackle the problem at hand, we perform three-dimensional Direct Numerical Simulation of a plane Couette flow with a suspension of neutrally buoyant deformable viscous hyper-elastic particles. We show that elasticity produces a shear-thinning effect in elastic suspensions (in comparison to rigid ones) and that it can be understood in terms of a reduction of the effective volume fraction of the suspension. The deformation modifies the particle motion reducing the level of mutual interaction. Normal stress differences will also be considered. European Research Council, Grant No. ERC-2013-CoG- 616186, TRITOS; SNIC (the Swedish National Infrastructure for Computing).

  20. Minimally invasive brow suspension for facial paralysis.

    Science.gov (United States)

    Costantino, Peter D; Hiltzik, David H; Moche, Jason; Preminger, Aviva

    2003-01-01

    To report a new technique for unilateral brow suspension for facial paralysis that is minimally invasive, limits supraciliary scar formation, does not require specialized endoscopic equipment or expertise, and has proved to be equal to direct brow suspension in durability and symmetry. Retrospective survey of a case series of 23 patients between January 1997 and December 2000. Metropolitan tertiary care center. Patients with head and neck tumors and brow ptosis caused by facial nerve paralysis. The results of the procedure were determined using the following 3-tier rating system: outstanding (excellent elevation and symmetry); acceptable (good elevation and fair symmetry); and unacceptable (loss of elevation). The results were considered outstanding in 12 patients, acceptable in 9 patients, and unacceptable in only 1 patient. One patient developed a hematoma, and 1 patient required a secondary adjustment. The technique has proved to be superior to standard brow suspension procedures with regard to scar formation and equal with respect to facial symmetry and suspension. These results have caused us to abandon direct brow suspension and to use this minimally invasive method in all cases of brow ptosis due to facial paralysis.

  1. Pitched Blade Turbine Efficiency at Particle Suspension

    Directory of Open Access Journals (Sweden)

    D. Ceres

    2010-01-01

    Full Text Available Mixing suspensions is a very important hydraulic operation. The pitched six-blade turbine is a widely-used axial-flow impeller. This paper deals with effect relative impeller size and particle content on theefficiency of a pitched six-blade turbine at particle suspension. Two pitched six-blade turbines were used in model measurements of just suspension impeller speed. The ratios of the vessel to agitator diameter D/d were 3 and 4.5. The measurements were carried out in a dish-bottomed vessel 300 mm in diameter. The just suspension impeller speeds were measured using an electrochemical method, and were checked visually. A 2.5 % NaCl water solution was used as the liquid phase, and glass particles with four equivalent diameters between 0.18 and 0.89 mmand volumetric concentration from 2.5 % to 40% were usedasthesolid phase. The criterion values πs=Po√Fr'3(d/D7 were calculated from the particle suspension and power consumption measurements. The dependencies of πs on particle content cv show that larger agitators are more efficient for higher particle content.

  2. Compounding rifampin suspensions with improved injectability for nasogastric enteral feeding tube administration.

    Science.gov (United States)

    de Villiers, Melgardt M; Vogel, Laura; Bogenschutz, Monica C; Fingerhut, Bonnie J; D'Silva, Joseph B; Moore, Anne

    2010-01-01

    Often medications that have to be administered to patients via a nasogastric enteral feeding tubes are only available as tablets and capsules with no suitable commercial liquid alternatives. In such situations, pharmacists and nurses have to compound the tablets and capsule contents into liquid suspension formulations for dosing. The risk of occlusion of the enteral tubes during administration is reduced by employing liquid suspensions that are composed of small and uniform particles, not subject to rapid rates of settling, resistant to caking, and easily and uniformly re-suspended upon agitation. Present techniques often employ a manual process, such as a mortar and pestle, to accomplish the particle size reduction and subsequent incorporation into a suitable liquid diluent. A new compounding device has been invented that employs an automated wet-milling process in a single-use disposable plastic container to compound the suspensions. The two processes were compared using Rifampin capsules and various liquid diluents. A prototype version of the new device was employed in the experiments. The physical characteristics of the compounded suspensions were evaluated by determining sedimentation rate, sedimentation volume, and particle size and shape using laser light scattering, optical microscopy, and scanning electron microscopy techniques. The use characteristic of the compounded suspensions was evaluated using a nasogastric tube inject ability test. The results indicated that suspensions prepared using the new device were more resistant to sedimentation and caking and were easier to re-disperse into a uniform mixture by gentle shaking. The results were a consequence of the particles generated by the new device which were found to be smaller and more uniform in shape and size. The suspensions prepared using the new device did not cause blockage of the enteral feeding tubes in comparison to those prepared using a mortar and pastle. In conclusion, the results indicate

  3. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  4. De Minimis Thresholds for Federal Building Metering Appropriateness

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  5. Turbine flow meter response in two-phase flows

    International Nuclear Information System (INIS)

    Shim, W.J.; Dougherty, T.J.; Cheh, H.Y.

    1996-01-01

    The purpose of this paper is to suggest a simple method of calibrating turbine flow meters to measure the flow rates of each phase in a two-phase flow. The response of two 50.8 mm (2 inch) turbine flow meters to air-water, two-phase mixtures flowing vertically in a 57 mm I.D. (2.25 inch) polycarbonate tube has been investigated for both upflow and downflow. The flow meters were connected in series with an intervening valve to provide an adjustable pressure difference between them. Void fractions were measured by two gamma densitometers, one upstream of the flow meters and the other downstream. The output signal of the turbine flow meters was found to depend only on the actual volumetric flow rate of the gas, F G , and liquid, F L , at the location of the flow meter

  6. Research on Operation Assessment Method for Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  7. A Method of Evaluating Operation of Electric Energy Meter

    Science.gov (United States)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  8. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il [Health Physics Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a {sup 252}Californium ({sup 252}Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

  9. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    International Nuclear Information System (INIS)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il

    2015-01-01

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a 252 Californium ( 252 Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered

  10. FUSION OF VENTURI AND ULTRASONIC FLOW METER FOR ENHANCED FLOW METER CHARACTERISTICS USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    K.V. Santhosh

    2015-04-01

    Full Text Available This paper proposes a technique for measurement of liquid flow using venturi and ultrasonic flow meter(UFM to have following objectives a to design a multi-sensor data fusion (MSDF architecture for using both the sensors, b improve sensitivity and linearity of venturi and ultrasonic flow meter, and c detect and diagnosis of faults in sensor if any. Fuzzy logic algorithm is used to fuse outputs of both the sensor and train the fuzzy block to produces output which has an improved characteristics in terms of both sensitivity and linearity. For identification of sensor faults a comparative test algorithm is designed. Once trained proposed technique is tested in real life, results show successful implementation of proposed objectives.

  11. How today's USM diagnostics solve metering problems[Ultrasonic meters

    Energy Technology Data Exchange (ETDEWEB)

    Lansing, John

    2005-07-01

    This paper discusses both basic and advanced diagnostic features of gas ultrasonic meters (USM), and how capabilities built into today's electronics can identify problems that often may not have been identified in the past. It primarily discusses fiscal-quality, multi-path USMs and does not cover issues that may be different with non-fiscal meters. Although USMs basically work the same, the diagnostics for each manufacturer does vary. All brands provide basic features as discussed in AGA 9. However, some provide advanced features that can be used to help identify issues such as blocked flow conditioners and gas compositional errors. This paper is based upon the Daniel USM design and the information presented here may or may not be applicable to other manufacturers. (author) (tk)

  12. Established Designs For Advanced Ground Based Astronomical Telescopes In The 1-meter To 4-meter Domain

    Science.gov (United States)

    Hull, Anthony B.; Barentine, J.; Legters, S.

    2012-01-01

    The same technology and analytic approaches that led to cost-effective unmitigated successes for the spaceborne Kepler and WISE telescopes are now being applied to meter-class to 4-meter-class ground telescopes, providing affordable solutions to ground astronomy, with advanced features as needed for the application. The range of optical and mechanical performance standards and features that can be supplied for ground astronomy shall be described. Both classical RC designs, as well as unobscured designs are well represented in the IOS design library, allowing heritage designs for both night time and day time operations, the latter even in the proximity of the sun. In addition to discussing this library of mature features, we will also describe a process for working with astronomers early in the definition process to provide the best-value solution. Solutions can include remote operation and astronomical data acquisition and transmission.

  13. Activity meters: Calibration and quality assurance measures by the manufacturer

    International Nuclear Information System (INIS)

    Pychlau, P.

    1992-01-01

    A manufacturer of ionisation chambers gives a general idea of such quality assurance programs as may be implemented after an agreement has been reached at the EC level on a guideline for activity meters. Further issues discussed include the final controls, calibration of activity meters by the manufacturer and the advantages that the participation in cooperate tests would offer over a mandatory calibration of activity meters. (orig./DG) [de

  14. Optimization on Measurement Method for Neutron Moisture Meter

    International Nuclear Information System (INIS)

    Gong Yalin; Wu Zhiqiang; Li Yanfeng; Wang Wei; Song Qingfeng; Liu Hui; Wei Xiaoyun; Zhao Zhonghua

    2010-01-01

    When the water in the measured material is nonuniformity, the measured results of the neutron moisture meter in the field may have errors, so the measured errors of the moisture meter associated with the water nonuniformity in material were simulated by Monte Carlo method. A new measurement method of moisture meter named 'transmission plus scatter' was put forward. The experiment results show that the new measurement method can reduce the error even if the water in the material is nonuniformity. (authors)

  15. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  16. Comprehensive evaluation of the Berthold LB1200 survey meter

    International Nuclear Information System (INIS)

    Davis, M.W.

    1986-05-01

    The performance of two Berthod LB1200 survey meters was evaluated under the influence of a range of beta and photon radiation energies and environmental conditions likely to be encountered in the field. The survey meters responded satisfactorily to the range of beta particle and photon radiation energies emitted by most radioisotopes commonly used in Canada. The survey meters performed acceptably under most of the environmental conditions tested here with the exception of radiofrequency interference and electrostatic charge

  17. Modeling Suspension and Continuation of a Process

    Directory of Open Access Journals (Sweden)

    Oleg Svatos

    2012-04-01

    Full Text Available This work focuses on difficulties an analyst encounters when modeling suspension and continuation of a process in contemporary process modeling languages. As a basis there is introduced general lifecycle of an activity which is then compared to activity lifecycles supported by individual process modeling languages. The comparison shows that the contemporary process modeling languages cover the defined general lifecycle of an activity only partially. There are picked two popular process modeling languages and there is modeled real example, which reviews how the modeling languages can get along with their lack of native support of suspension and continuation of an activity. Upon the unsatisfying results of the contemporary process modeling languages in the modeled example, there is presented a new process modeling language which, as demonstrated, is capable of capturing suspension and continuation of an activity in much simpler and precise way.

  18. Phagocytosis in phosphate chromium (III) suspensions

    International Nuclear Information System (INIS)

    Cruz-Arencibia, Jorge; Fano Machín, Yoiz; Cruz-Morales, Ahmed; Tamayo Fuente, Radamés; Morín-Zorrilla, José

    2015-01-01

    Phagocytosis in vivo and in vitro of a suspension of chromic phosphate (III) labeled with 51 Cr and 32 P is studied. The radioactive particles dispersed in a media of 2 % gelatin in acetate buffer pH 4-4.5 have a predominant size of 0.8 μm and 5 μm. According with biodistribution experiments in rats after 30 minutes near the 80 % of radioactivity is registered in the liver, probably associated with phagocytosis of the particles by liver Kupffer cells. Is also showed that the suspension particles are phagocytized in vitro by mouse peritoneal macrophages. This facts indicate that the studied suspension have appropriate characteristics to be used in radiosynoviorthesis according to the principal action mechanism described for this procedure, particles phagocytosis by cells present in the inflamed synovium. (author)

  19. Crust formation in drying colloidal suspensions

    KAUST Repository

    Style, R. W.

    2010-06-30

    During the drying of colloidal suspensions, the desiccation process causes the suspension near the air interface to consolidate into a connected porous matrix or crust. Fluid transport in the porous medium is governed by Darcy\\'s law and the equations of poroelasticity, while the equations of colloid physics govern processes in the suspension. We derive new equations describing this process, including unique boundary conditions coupling the two regions, yielding a moving-boundary model of the concentration and stress profiles during drying. A solution is found for the steady-state growth of a nedimensional crust during constant evaporation rate from the surface. The solution is used to demonstrate the importance of the system boundary conditions on stress profiles and diffusivity in a drying crust. © 2011 The Royal Society.

  20. Pharmacokinetics of a porcine insulin zinc suspension in diabetic dogs.

    Science.gov (United States)

    Graham, P A; Nash, A S; McKellar, Q A

    1997-10-01

    Ten dogs with naturally occurring diabetes mellitus were injected with a highly purified porcine insulin zinc suspension at a dose according to their expected requirement. Plasma insulin and glucose concentrations were measured at two-hourly intervals over 24 hours following injection. There were either one or two peaks in plasma insulin concentration: one at about four hours (mean 4.3 +/- 1.3 [SD]) and another at about 11 hours (mean 11 +/- 1.85) after the injection. The second insulin peak was seen in only eight dogs. Persistence of elevated plasma insulin concentrations ranged from 14 to 24 hours (mean 17.4 +/- 3.65). These results compare favourably with those published for other intermediate-acting insulin preparations used to treat canine diabetes mellitus and suggest that this preparation has useful properties for the successful management of many canine diabetics.

  1. A Novel Smart Meter Controlling System with Dynamic IP Addresses

    DEFF Research Database (Denmark)

    Manembu, Pinrolinvic; Welang, Brammy; Kalua Lapu, Aditya

    2017-01-01

    Smart meters are the electronic devices for measuring energy consumption in real time. Usually, static public IP addresses are allocated to realize the point-to-point (P2P) communication and remote controlling for smart metering systems. This, however, restricts the wide deployment of smart meters......, due to the deficiency of public IP resources. This paper proposes a novel subscription-based communication architecture for the support of dynamic IP addresses and group controlling of smart meters. The paper evaluates the proposed architecture by comparing the traditional P2P architecture...

  2. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  3. Performance Testing of Suspension Plasma Sprayed Thermal Barrier Coatings Produced with Varied Suspension Parameters

    Directory of Open Access Journals (Sweden)

    Nicholas Curry

    2015-07-01

    Full Text Available Suspension plasma spraying has become an emerging technology for the production of thermal barrier coatings for the gas turbine industry. Presently, though commercial systems for coating production are available, coatings remain in the development stage. Suitable suspension parameters for coating production remain an outstanding question and the influence of suspension properties on the final coatings is not well known. For this study, a number of suspensions were produced with varied solid loadings, powder size distributions and solvents. Suspensions were sprayed onto superalloy substrates coated with high velocity air fuel (HVAF -sprayed bond coats. Plasma spray parameters were selected to generate columnar structures based on previous experiments and were maintained at constant to discover the influence of the suspension behavior on coating microstructures. Testing of the produced thermal barrier coating (TBC systems has included thermal cyclic fatigue testing and thermal conductivity analysis. Pore size distribution has been characterized by mercury infiltration porosimetry. Results show a strong influence of suspension viscosity and surface tension on the microstructure of the produced coatings.

  4. Suspension Hydrogen Reduction of Iron Oxide Concentrates

    Energy Technology Data Exchange (ETDEWEB)

    H.Y. Sohn

    2008-03-31

    The objective of the project is to develop a new ironmaking technology based on hydrogen and fine iron oxide concentrates in a suspension reduction process. The ultimate objective of the new technology is to replace the blast furnace and to drastically reduce CO2 emissions in the steel industry. The goals of this phase of development are; the performance of detailed material and energy balances, thermochemical and equilibrium calculations for sulfur and phosphorus impurities, the determination of the complete kinetics of hydrogen reduction and bench-scale testing of the suspension reduction process using a large laboratory flash reactor.

  5. Intelligent systems of the vehicles’ suspension

    Science.gov (United States)

    Yurlin, D.

    2018-02-01

    The article is devoted to the current condition of car’s active suspension system. It presents the tendencies in development of the active systems of suspension system, adjustable elements incorporated in them and the companies succeeded in designing such systems. It also mirrors the problem of impact of active systems on car’s safety and their importance for the driver. Advantages and disadvantages of the most common types of active elements are being described, analyzed and compared. The author concludes about the perspectives of these systems’ development.

  6. Unifying Suspension and Granular flows near Jamming

    Directory of Open Access Journals (Sweden)

    DeGiuli Eric

    2017-01-01

    Full Text Available Rheological properties of dense flows of hard particles are singular as one approaches the jamming threshold where flow ceases, both for granular flows dominated by inertia, and for over-damped suspensions. Concomitantly, the lengthscale characterizing velocity correlations appears to diverge at jamming. Here we review a theoretical framework that gives a scaling description of stationary flows of frictionless particles. Our analysis applies both to suspensions and inertial flows of hard particles. We report numerical results in support of the theory, and show the phase diagram that results when friction is added, delineating the regime of validity of the frictionless theory.

  7. Gravity Drainage Kinetics of Papermaking Fibrous Suspensions

    Directory of Open Access Journals (Sweden)

    Przybysz Piotr

    2014-12-01

    Full Text Available The study analyses application possibilities of filtration and thickening models in evaluation of papermaking suspension drainage rate. The authors proposed their own method to estimate the drainage rate on the basis of an existing Ergun capillary model of liquid flow through a granular material. The proposed model was less sensitive to porosity changes than the Ergun model. An empirical verification proved robustness of the proposed approach. Taking into account discrepancies in the published data concerning how the drainage velocity of papermaking suspension is defined, this study examines which of the commonly applied models matches experimental results the best.

  8. Survey meter using novel inorganic scintillators

    International Nuclear Information System (INIS)

    Yoshikawa, Akira; Fukuda, Kentaro; Kawaguchi, Noriaki; Kamada, Kei; Fujimoto, Yutaka; Yokota, Yuui; Kurosawa, Shunsuke; Yanagida, Takayuki

    2012-01-01

    Single crystal scintillator materials are widely used for detection of high-energy photons and particles. There is continuous demand for new scintillator materials with higher performance because of increasing number of medical, industrial, security and other applications. This article presents the recent development of three novel inorganic scintillators; Pr-doped Lu 3 Al 5 O 12 (Pr:LuAG), Ce doped Gd 3 (Al, Ga) 5 O 12 (Ce:GAGG) and Ce or Eu-doped 6 LiCaAlF 6 (Ce:LiCAF, Eu:LiCAF). Pr:LuAG shows very interesting scintillation properties including very fast decay time, high light yield and excellent energy resolution. Taking the advantage of these properties, positron emission mammography (PEM) equipped with Pr:LuAG were developed. Ce:GAGG shows very high light yield, which is much higher than that of Ce:LYSO. Survey meter using Ce:GAGG is developed using this scintillator. Ce:LiCAF and Eu:LiCAF were developed for neutron detection. The advantage and disadvantage are discussed comparing with halide scintillators. Eu-doped LiCAF indicated five times higher light yield than that of existing Li-glass. It is expected to be used as the alternative of 3 He. (author)

  9. Meter-wavelength VLBI. III. Pulsars

    International Nuclear Information System (INIS)

    Vandenberg, N.R.; Clark, T.A.; Clark, W.C.; Erickson, W.C.; Resch, G.M.; Broderick, J.J.

    1976-01-01

    The results and analysis of observations of pulsars, especially the Crab Nebula pulsar, taken during a series of meter-wavelength very long baseline interferometry (VLBI) experiments are discussed. Based on a crude 144 MHz visibility curve which is consistent with a Gaussian brightness distribution, the measured visibilities at 196, 111, and 74 MHz were interpreted to yield apparent angular diameters (at half-power) of 0 .03 +- 0 .01, 0 .07 +- 0 .01, and 0 .18 +- 0 .01, respectively. These sizes scale approximately as wavelength-squared, and the 74 MHz size agrees with recent observations using interplanetary scintillation techniques.The VLBI-measured total flux densities lie on the extrapolation from higher frequencies of the pulsing flux densities. Variations in the total flux density up to 25 percent were observed. A lack of fine structure other than the pulsar in the nebula is indicated by our simple visibility curves. The pulse shapes observed with the interferometer are similar to single-dish measurements at 196 MHz but reveal a steady, nonpulsing component at 111 MHz. The ratio of pulsing to total power was approximately equal to one-half but varied with time. No pulsing power was detected at 74 MHz. It was found that four strong, low-dispersion pulsars were only slightly resolved

  10. Two-Phase Quality/Flow Meter

    Science.gov (United States)

    Moerk, J. Steven (Inventor); Youngquist, Robert C. (Inventor); Werlink, Rudy J. (Inventor)

    1999-01-01

    A quality and/or flow meter employs a capacitance probe assembly for measuring the dielectric constant of flow stream, particularly a two-phase flow stream including liquid and gas components.ne dielectric constant of the flow stream varies depending upon the volume ratios of its liquid and gas components, and capacitance measurements can therefore be employed to calculate the quality of the flow, which is defined as the volume ratio of liquid in the flow to the total volume ratio of gas and liquid in the flow. By using two spaced capacitance sensors, and cross-correlating the time varying capacitance values of each, the velocity of the flow stream can also be determined. A microcontroller-based processing circuit is employed to measure the capacitance of the probe sensors.The circuit employs high speed timer and counter circuits to provide a high resolution measurement of the time interval required to charge each capacitor in the probe assembly. In this manner, a high resolution, noise resistant, digital representation of each of capacitance value is obtained without the need for a high resolution A/D converter, or a high frequency oscillator circuit. One embodiment of the probe assembly employs a capacitor with two ground plates which provide symmetry to insure that accurate measurements are made thereby.

  11. On Calibration of pH Meters

    Directory of Open Access Journals (Sweden)

    Da-Ming Zhu

    2005-04-01

    Full Text Available The calibration of pH meters including the pH glass electrode, ISE electrodes,buffers, and the general background for calibration are reviewed. Understanding of basicconcepts of pH, pOH, and electrode mechanism is emphasized. New concepts of pH, pOH,as well as critical examination of activity, and activity coefficients are given. Theemergence of new solid state pH electrodes and replacement of the salt bridge with aconducting wire have opened up a new horizon for pH measurements. A pH buffer solutionwith a conducting wire may be used as a stable reference electrode. The misleadingunlimited linear Nernstian slope should be discarded. Calibration curves with 3 nonlinearportions for the entire 0—14 pH range due to the isoelectric point change effect areexplained. The potential measurement with stirring or unstirring and effects by double layer(DL and triple layer (TL will be discussed.

  12. Rheological Properties of Aqueous Nanometric Alumina Suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chuanping [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    Colloidal processing is an effective and reliable approach in the fabrication of the advanced ceramic products. Successful colloidal processing of fine ceramic powders requires accurate control of the rheological properties. The accurate control relies on the understanding the influences of various colloidal parameters on the rheological properties. Almost all research done on the rheology paid less attention to the interactions of particle and solvent. However, the interactions of the particles are usually built up through the media in which the particles are suspended. Therefore, interactions of the particle with the media, the adsorbed layers on the particle surface, and chemical and physical properties of media themselves must influence the rheology of the suspension, especially for the dense suspensions containing nanosized particles. Relatively little research work has been reported in this area. This thesis addresses the rheological properties of nanometric alumina aqueous suspensions, and paying more attention to the interactions between particle and solvent, which in turn influence the particle-particle interactions. Dense nanometric alumina aqueous suspensions with low viscosity were achieved by environmentally-benign fructose additives. The rheology of nanometric alumina aqueous suspensions and its variation with the particle volume fraction and concentration of fructose were explored by rheometry. The adsorptions of solute (fructose) and solvent (water) on the nanometric alumina particle surfaces were measured and analyzed by TG/DSC, TOC, and NMR techniques. The mobility of water molecules in the suspensions and its variation with particle volume fractions and fructose additive were determined by the 17O NMR relaxation method. The interactions between the nanometric alumina particles in water and fructose solutions were investigated by AFM. The results indicated that a large number of water layers were physically bound on the particles

  13. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  14. Decoupling Suspension Controller Based on Magnetic Flux Feedback

    Directory of Open Access Journals (Sweden)

    Wenqing Zhang

    2013-01-01

    Full Text Available The suspension module control system model has been established based on MIMO (multiple input and multiple output state feedback linearization. We have completed decoupling between double suspension points, and the new decoupling method has been applied to CMS04 magnetic suspension vehicle in national mid-low-speed maglev experiment field of Tangshan city in China. Double suspension system model is very accurate for investigating stability property of maglev control system. When magnetic flux signal is taken back to the suspension control system, the suspension module’s antijamming capacity for resisting suspension load variety has been proved. Also, the external force interference has been enhanced. As a result, the robustness and stability properties of double-electromagnet suspension control system have been enhanced.

  15. On the Benefits of Semi-Active Suspensions with Inerters

    Directory of Open Access Journals (Sweden)

    Xin-Jie Zhang

    2012-01-01

    Full Text Available Inerters have become a hot topic in recent years especially in vehicle, train, building suspension systems, etc. Eight different layouts of suspensions were analyzed with a quarter-car model in this paper. Dimensionless root mean square (RMS responses of the sprung mass vertical acceleration, the suspension travel, and the tire deflection are derived which were used to evaluate the performance of the quarter-car model. The behaviour of semi-active suspensions with inerters using Groundhook, Skyhook, and Hybrid control has been evaluated and compared to the performance of passive suspensions with inerters. Sensitivity analysis was applied to the development of a high performance semi-active suspension with an inerter. Numerical simulations indicate that a semi-active suspension with an inerter has much better performance than the passive suspension with an inerter, especially with the Hybrid control method, which has the best compromise between comfort and road holding quality.

  16. Decoupling suspension controller based on magnetic flux feedback.

    Science.gov (United States)

    Zhang, Wenqing; Li, Jie; Zhang, Kun; Cui, Peng

    2013-01-01

    The suspension module control system model has been established based on MIMO (multiple input and multiple output) state feedback linearization. We have completed decoupling between double suspension points, and the new decoupling method has been applied to CMS04 magnetic suspension vehicle in national mid-low-speed maglev experiment field of Tangshan city in China. Double suspension system model is very accurate for investigating stability property of maglev control system. When magnetic flux signal is taken back to the suspension control system, the suspension module's antijamming capacity for resisting suspension load variety has been proved. Also, the external force interference has been enhanced. As a result, the robustness and stability properties of double-electromagnet suspension control system have been enhanced.

  17. Measurements on an electromagnetic active suspension system for automotive applications

    NARCIS (Netherlands)

    Gysen, B.L.J.; Paulides, J.J.H.; Lomonova, E.A.; Encica, L.; Gysen, B.L.J.; Jansen, J.W.; Krop, D.C.J.

    2008-01-01

    Abstract—This paper describes the specifications for active suspension systems and provides an electromagnetic solution. Electromagnetic actuation and preliminary control strategies are investigated in order to achieve a suspension system with the ability to absorb road irregularities and perform

  18. Fuzzy logic control of vehicle suspensions with dry friction nonlinearity

    Indian Academy of Sciences (India)

    Fuzzy logic control; active vehicle suspension; suspension space. 1. ... surface unevenness, stability and directional control during handling ..... Burton A W, Truscott A J, Wellstead P E 1995 Analysis, modeling and control of an advanced.

  19. Development of a novel vortex flow meter for downhole use

    NARCIS (Netherlands)

    Schiferli, W.; Cheng, L.K.

    2008-01-01

    Due to the increasing complexity of oil and gas wells, the demand for instrumentation to measure conditions inside well tubing below the surface is growing rapidly. A robust meter was designed to measure liquid flows at downhole conditions. The meter is based on a specially-designed bluff body to

  20. Analysis of a quantum nondemolition speed-meter interferometer

    International Nuclear Information System (INIS)

    Purdue, Patricia

    2002-01-01

    In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this--a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power

  1. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    High levels of water losses in distribution systems are the main challenge that water utilities in developing countries currently face. The water meter is an essential tool for both the utility and the customers to measure and monitor consumption. When metering is inefficient and coupled with low tariffs, the financial ...

  2. The Solar Energy Trifecta: Solar + Storage + Net Metering | State, Local,

    Science.gov (United States)

    and Tribal Governments | NREL The Solar Energy Trifecta: Solar + Storage + Net Metering The Solar Energy Trifecta: Solar + Storage + Net Metering February 12, 2018 by Benjamin Mow Massachusetts (DPU) seeking an advisory ruling on the eligibility of pairing solar-plus-storage systems with current

  3. 40 CFR 1065.230 - Raw exhaust flow meter.

    Science.gov (United States)

    2010-07-01

    ... the following cases, you may use a raw exhaust flow meter signal that does not give the actual value... dew and pressure, p total at the flow meter inlet. Use these values in emission calculations according... CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.230 Raw exhaust...

  4. Justification of the Utility of Introducing Smart Meters in Latvia

    Directory of Open Access Journals (Sweden)

    Kunickis M.

    2015-12-01

    Full Text Available Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale.

  5. Construction and calibration of high time resolution gas pressure meter

    International Nuclear Information System (INIS)

    Rossi, J.O.; Santos, C.; Ueda, M.

    1989-11-01

    In this report, the construction and calibration of a gas pressure meter with a time resolution better than 20 μs are described. The meter consists basically of a sensor of the FIG (Fast Ionization Gauge) type and an adequate electronic circuit. A 6AU6A pentode vacuum tube without the glass envelope is used as the sensor head. (author) [pt

  6. A wireless mesh communication protocol for smart-metering

    NARCIS (Netherlands)

    Geelen, D.J.M.; Kempen, van G.M.P.; Hoogstraten, van F.; Liotta, A.

    2012-01-01

    Worldwide there has been increasing interest over the past few years for so-called "Smart Meters", in academia, governments and in industry. Such smart-metering systems need a way to communicate the collected data reliably and cost efficiently to the back-office for analysis. Several competing

  7. Performance of a Tilt Current Meter in the Surf Zone

    DEFF Research Database (Denmark)

    Hansen, Asger Bendix; Carstensen, Stefan; Christensen, Drude Fritzbøger

    2017-01-01

    Tilt Current Meters (TCM’s) are relatively simple and inexpensive instruments for measuring currents in rivers and inthe sea. Their low cost and easy deployment means that a relatively large number of TCM’s can be deployed comparedto more conventional current meters such as Acoustic Doppler...

  8. 40 CFR 92.122 - Smoke meter calibration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Smoke meter calibration. 92.122 Section 92.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... meter calibration. The smokemeter shall be checked according to the following procedure prior to each...

  9. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    Today, in water and wastewater industry a lot of mechanical-volumetric flow meters are used for the navigation of the produced water and the data of these flow meters, due to use in a wide geographical range, is done physically and by in person presence. All this makes reading the data costly and, in some cases, due to ...

  10. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    Many patients were referred to Kololo polyclinic laboratory to have their blood glucose checked because the values obtained on the patients' glucose meter systems did not tally with familiar clinical signs and symptoms. This prompted an experimental set up to check glucose meter systems using a larger number of patients.

  11. Integration of auditory and tactile inputs in musical meter perception.

    Science.gov (United States)

    Huang, Juan; Gamble, Darik; Sarnlertsophon, Kristine; Wang, Xiaoqin; Hsiao, Steven

    2013-01-01

    Musicians often say that they not only hear but also "feel" music. To explore the contribution of tactile information to "feeling" music, we investigated the degree that auditory and tactile inputs are integrated in humans performing a musical meter-recognition task. Subjects discriminated between two types of sequences, "duple" (march-like rhythms) and "triple" (waltz-like rhythms), presented in three conditions: (1) unimodal inputs (auditory or tactile alone); (2) various combinations of bimodal inputs, where sequences were distributed between the auditory and tactile channels such that a single channel did not produce coherent meter percepts; and (3) bimodal inputs where the two channels contained congruent or incongruent meter cues. We first show that meter is perceived similarly well (70-85 %) when tactile or auditory cues are presented alone. We next show in the bimodal experiments that auditory and tactile cues are integrated to produce coherent meter percepts. Performance is high (70-90 %) when all of the metrically important notes are assigned to one channel and is reduced to 60 % when half of these notes are assigned to one channel. When the important notes are presented simultaneously to both channels, congruent cues enhance meter recognition (90 %). Performance dropped dramatically when subjects were presented with incongruent auditory cues (10 %), as opposed to incongruent tactile cues (60 %), demonstrating that auditory input dominates meter perception. These observations support the notion that meter perception is a cross-modal percept with tactile inputs underlying the perception of "feeling" music.

  12. Development and Testing of Infrared Water Current Meter | Ezenne ...

    African Journals Online (AJOL)

    Continuous monitoring of the river flow is essential for assessing water availability. River flow velocity is crucial to simulate discharge hydrographs of water in the hydrological system.This study developed a digital water current meter with infrared. The infrared current meter was tested using Ebonyi River at Obollo-Etiti and ...

  13. Attacks and their Defenses for Advanced Metering Infrastructure

    DEFF Research Database (Denmark)

    Lighari, Sheeraz Niaz; Hussain, Dil Muhammad Akbar; Bak-Jensen, Birgitte

    2014-01-01

    The smart grid is the digitized, modernized, updated version of archaic traditional electric grid. Advanced Metering Infrastructure (AMI) is an imperative part of the smart grid. It has replaced legacy metering, as it reports the energy consumption to the utility automatically through communicati...

  14. 7 CFR 801.6 - Tolerances for moisture meters.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for moisture meters. 801.6 Section 801.6 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD... FOR GRAIN INSPECTION EQUIPMENT § 801.6 Tolerances for moisture meters. (a) The maintenance tolerances...

  15. "Restorative Practices" Offer Alternatives to Suspension

    Science.gov (United States)

    Shah, Nirvi

    2012-01-01

    At City Springs and many other schools across the country, restorative practices are about holding students accountable and getting them to right a wrong. The approach is getting more notice than ever as criticism grows of zero-tolerance disciplinary policies that often require out-of-school suspension and expulsion. Educators are turning to…

  16. Mesoscopic electrohydrodynamic simulations of binary colloidal suspensions

    NARCIS (Netherlands)

    Rivas, Nicolas; Frijters, Stefan; Pagonabarraga, Ignacio; Harting, Jens

    2018-01-01

    A model is presented for the solution of electrokinetic phenomena of colloidal suspensions in fluid mixtures. We solve the discrete Boltzmann equation with a Bhatnagar-Gross-Krook collision operator using the lattice Boltzmann method to simulate binary fluid flows. Solvent-solvent and solvent-solute

  17. 75 FR 68704 - Suspension of Community Eligibility

    Science.gov (United States)

    2010-11-09

    ... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency 44 CFR Part 64 [Docket ID FEMA-2010-0003; Internal Agency Docket No. FEMA-8155] Suspension of Community Eligibility AGENCY: Federal.... Acadia Parish. Emerg; February 4, 1981, Reg; November 26, 2010, Susp. Iota, Town of, Acadia 220005...

  18. Suspension of Water Droplets on Individual Pillars

    DEFF Research Database (Denmark)

    Tóth, T.; Ferraro, D.; Chiarello, E.

    2011-01-01

    We report results of extensive experimental and numerical studies on the suspension of water drops deposited on cylindrical pillars having circular and square cross sections and different wettabilities. In the case of circular pillars, the drop contact line is pinned to the whole edge contour unt...

  19. ENHANCEMENT OF DURABILITY OF TRACTOR SUSPENSION AXLES

    Directory of Open Access Journals (Sweden)

    I. Doshchechkina

    2017-12-01

    Full Text Available The ‘soft’ nitriding of the suspension axle surface of the T150K tractor at the depth of 0.08 mm enables us to enhance its constructive strength, to increase its service life by 25 % and have a considerable economic effect.

  20. Pair-correlations in swimmer suspensions

    Science.gov (United States)

    Nambiar, Sankalp; Subramanian, Ganesh

    2017-11-01

    Suspensions of rear-actuated swimming microorganisms, such as E.coli, exhibit several interesting phenomena including spontaneous pattern formation above a critical concentration, novel rheological properties, shear-induced concentration banding etc. Explanations based on mean-field theory are only qualitative, since interactions between swimmers are important for typical experimental concentrations. We analytically characterize the hydrodynamic pair-interactions in a quiescent suspension of slender straight swimmers. The pair-correlation, calculated at leading order by integrating the swimmer velocity disturbances along straight trajectories, decays as 1/r2 for r >> L (L being the swimmer size). This allows us to characterize both polar and nematic correlations in an interacting swimmer suspension. In the absence of correlations, the velocity covariance asymptotes from a constant for r > L, the latter being characteristic of a suspension of non-interacting point force-dipoles. On including correlations, the slow decay of the pair-orientation correlation leads to an additional contribution to the velocity covariance that diverges logarithmically with system size.

  1. Baltimore District Tackles High Suspension Rates

    Science.gov (United States)

    Maxwell, Lesli A.

    2007-01-01

    This article reports on how the Baltimore District tackles its high suspension rates. Driven by an increasing belief that zero-tolerance disciplinary policies are ineffective, more educators are embracing strategies that do not exclude misbehaving students from school for offenses such as insubordination, disrespect, cutting class, tardiness, and…

  2. Absorption Spectra of Gold Nanoparticle Suspensions

    Science.gov (United States)

    Anan'eva, M. V.; Nurmukhametov, D. R.; Zverev, A. S.; Nelyubina, N. V.; Zvekov, A. A.; Russakov, D. M.; Kalenskii, A. V.; Eremenko, A. N.

    2018-02-01

    Three gold nanoparticle suspensions are obtained, and mean radii in distributions - (6.1 ± 0.2), (11.9 ± 0.3), and (17.3 ± 0.7) nm - are determined by the transmission electron microscopy method. The optical absorption spectra of suspensions are obtained and studied. Calculation of spectral dependences of the absorption index of suspensions at values of the gold complex refractive index taken from the literature showed a significant deviation of experimental and calculated data in the region of 450-800 nm. Spectral dependences of the absorption of suspensions are simulated within the framework of the Mie-Drude theory taking into account the interband absorption in the form of an additional term in the imaginary part of the dielectric permittivity of the Gaussian type. It is shown that to quantify the spectral dependences in the region of the plasmon absorption band of nanoparticles, correction of the parameters of the interband absorption is necessary in addition to the increase of the relaxation parameter of the Drude theory. Spectral dependences of the dielectric permittivity of gold in nanodimensional state are refined from the solution of the inverse problem. The results of the present work are important for predicting the special features of operation of photonic devices and optical detonators based on gold nanoparticles.

  3. Yield stress of alumina-zirconia suspensions

    International Nuclear Information System (INIS)

    Ramakrishnan, V.; Pradip; Malghan, S.G.

    1996-01-01

    The yield stress of concentrated suspensions of alumina, zirconia, and mixed alumina-zirconia powders was measured by the vane technique as a function of solids loading, relative amounts of alumina and zirconia, and pH. At the isoelectric point (IEP), the yield stress varied as the fourth power of the solids loading. The relative ratio of alumina and zirconia particles was important in determining the yield stress of the suspension at the IEP. The yield stress of single and mixed suspensions showed a marked variation with pH. The maximum value occurred at or near the IEP of the suspension. The effect of electrical double-layer forces on the yield stress can be described on the basis of the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory. A normalized yield stress--that is, the ratio of the yield stress at a given pH to the yield stress at the IEP predicted by this model--showed good correlation with experimental data

  4. Alternatives to School Disciplinary and Suspension Problems.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Div. of Instruction.

    Policies and procedures for disciplining students should be designed to teach them responsibility, rather than simply punish them. Providing educational opportunities to behavioral deviants is a problem that does not have a simple solution. However, alternatives to suspension or expulsion must be attempted before these disciplinary actions are…

  5. Metering instrument of quality factor Q of gravitational wave antenna

    International Nuclear Information System (INIS)

    Jia-yan, C.; Tong-ren, G.

    1982-01-01

    The quality factor, Q, of gravitational wave antenna depends on the material property as well as external conditions, such as temperature, residual pressure in vacuum tank, support type, additional loss from transducer on antenna, etc. In order to find out the relationship between the antenna Q and external conditions automatical operating in succession is required. The authors have designed and made a metering instrument for quality factor Q. The metering instrument of Q can measure Q of the metal cylinder and other bar of higher Q. It can give data of the measurement at regular intervals as desired. It can measure accurately the longitudinal fundamental mode frequency of the cylinder with a digital frequency meter record oscillating signal from metering instrument. Because the metering instrument excites free-vibration of the cylinder with free-running type and keep up the stationary amplitude for a long time. (Auth.)

  6. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  7. Electrostratic stabilization of suspensions in non-aqueous media

    NARCIS (Netherlands)

    Hoeven, van der P.C.

    1991-01-01

    Concentrated suspensions of detergent powder solids in a liquid nonionic surfactant are considered for practical application as liquid detergent products. If no precautions are taken, upon storage the viscosity of such suspensions increases and the pourability drops because the suspensions are

  8. Preview based control of suspension systems for commercial vehicles

    NARCIS (Netherlands)

    Muijderman, J.H.E.A.; Kok, J.J.; Huisman, R.G.M.; Veldpaus, F.E.; van Heck, J.G.A.M.

    1999-01-01

    An active suspension with preview is developed for the rear axle of a commercial vehicle. The obtained improvements are promising and justify further investigation of the more feasible semi-active suspensions with preview. The inherent non-linearity of semi-active suspensions with switching shock

  9. Professor Jesse W. Beams and the first practical magnetic suspension

    Science.gov (United States)

    Allaire, P. E.; Humphris, R. R.; Lewis, D. W.

    1992-01-01

    Dr. Jesse W. Beams developed the first practical magnetic suspension for high speed rotating devices. The devices included high speed rotating mirrors, ultracentrifuges, and high speed centrifugal field rotors. A brief biography of Dr. Beams is presented, and the following topics are discussed: (1) early axial magnetic suspension for ultracentrifuges; and (2) magnetic suspension for high centrifugal fields.

  10. Fuzzy logic control of vehicle suspensions with dry friction nonlinearity

    Indian Academy of Sciences (India)

    We design and investigate the performance of fuzzy logic-controlled (FLC) active suspensions on a nonlinear vehicle model with four degrees of freedom, without causing any degeneration in suspension working limits. Force actuators were mounted parallel to the suspensions. In this new approach, linear combinations of ...

  11. Behaviour of humic-bentonite aggregates in diluted suspensions ...

    African Journals Online (AJOL)

    Formation and disaggregation of micron-size aggregates in a diluted suspension made up of HSs and bentonite (B) were studied by tracing distribution of aggregate sizes and their counts in freshly prepared and aged suspensions, and at high (10 000) and low (1.0) [HS]/[B] ratios. Diluted HSB suspensions are unstable ...

  12. 15 CFR 2011.207 - Suspension of the certificate system.

    Science.gov (United States)

    2010-01-01

    ..., SYRUPS AND MOLASSES Specialty Sugar § 2011.207 Suspension of the certificate system. (a) Suspension. The.... Notice of such suspension and the effective date thereof shall be published in the Federal Register. (b... such reinstatement and the effective date thereof shall be published in the Federal Register. (c...

  13. 13 CFR 120.660 - Suspension or revocation.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Suspension or revocation. 120.660 Section 120.660 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Suspension Or Revocation of Participant in Secondary Market § 120.660 Suspension or revocation. (a...

  14. 39 CFR 3001.114 - Suspension pending review.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Suspension pending review. 3001.114 Section 3001... Suspension pending review. (a) Application. Application for suspension of a determination of the Postal Service to close or consolidate any post office pending the outcome of an appeal to the Postal Regulatory...

  15. 21 CFR 520.905a - Fenbendazole suspension.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Fenbendazole suspension. 520.905a Section 520.905a... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.905a Fenbendazole suspension. (a) Specifications. Each milliliter of suspension contains 100 milligrams (mg) fenbendazole. (b...

  16. Combining smart metering with successful marketing; Smart Metering mit erfolgreichem Marketing verbinden

    Energy Technology Data Exchange (ETDEWEB)

    Luckhardt, Sina [EVB Energie AG, Velbert (Germany)

    2009-07-15

    Smart metering can be implemented in various ways. Apart from data transmission via powerline cables, also teletransmission via GPRS may be advantageous. A current project investigates both communication strategies which can also be used in parallel, especially by major utilities with the appropriate infrastructure. In the case of concrete implementation, it has been found that the communication with users must be clear in order to give them an idea of the advantages of the new technologies, and that an appropriate marketing strategy must be developed for successful rollout. (orig.)

  17. A parametric comparative study of electrocoagulation and coagulation using ultrafine quartz suspensions.

    Science.gov (United States)

    Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde

    2009-11-15

    This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.

  18. Measurement of radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Helmrot, E.; Carlsson, G. A.

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs. (authors)

  19. EU data protection and smart metering. Legal boundary conditions; EU-Datenschutz und Smart Metering. Rechtliche Rahmenbedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Hladjk, Joerg [Praxisgruppe European Data Protection and Privacy, Hunton and Williams, Bruessel (Belgium)

    2011-07-01

    With the introduction of smart metering, the problem of data protection arises. The independent Article 29 Data Protection Group of the European Commission drew up an expert opinion with the intention of explaining the applicable EU data protection regulations for the smart metering technology in the power supply sector. (orig.)

  20. Calibration of a radiation survey meter using Cs-137 gamma source

    International Nuclear Information System (INIS)

    Khalid, R. O.

    2005-07-01

    The survey instrument smartIon was calibrated at the Secondary Standard Dosimetry Laboratory, Sudan Atomic Energy Commission, in terms of kerma, free in air using Cs-137 gamma radiation. All the calibrations were performed using the reference instrument spherical ionization chamber LS-01. This reference instrument has been calibrated at the International Atomic Energy Agency, Vienna for x-rays, 137 Cs and 60 Co gamma radiation. The air kerma calibration factors for the instrument were determined as the ratio of the dose rates obtained with the reference standard chamber LS-01 and the dose rates of the instrument under calibration. The uncertainties for the survey meter smartIon and another survey meter RADOS were obtained and the results compared with the uncertainty for the reference standard chamber. Also, the values of dose rates were obtained for various angles of the incident beam, by changing the angle by which the radiation was incident on the sensitive point of the instrument.(Author)