  1. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  2. Association of dynamic susceptibility contrast enhanced MR Perfusion parameters with prognosis in elderly patients with glioblastomas

    Energy Technology Data Exchange (ETDEWEB)

    Jabehdar Maralani, Pejman [University of Toronto, Department of Medical Imaging, Sunnybrook Health Sciences Center, Toronto, ON (Canada); Melhem, Elias R.; Herskovits, Edward H. [University of Maryland Medical Center, Department of Radiology, Baltimore, MD (United States); Wang, Sumei; Voluck, Matthew R.; Learned, Kim O.; Mohan, Suyash [Perelman School of Medicine at University of Pennsylvania, Department of Radiology, Division of Neuroradiology, Philadelphia, PA (United States); Kim, Sang Joon [University of Ulsan Asan Medical Center, Department of Radiology, Songpa-gu, Seoul (Korea, Republic of); O' Rourke, Donald M. [Perelman School of Medicine at University of Pennsylvania, Department of Surgery, Division of Neurosurgery, Philadelphia, PA (United States)

    2015-09-15

    We aimed to evaluate the prognostic value of dynamic susceptibility contrast (DSC) MR perfusion in elderly patients with glioblastomas (GBM). Thirty five patients aged ≥65 and 35 aged <65 years old, (referred to as elderly and younger, respectively) were included in this retrospective study. The median relative cerebral volume (rCBV) from the enhancing region (rCBV{sub ER-Med}) and immediate peritumoral region (rCBV{sub IPR-Med}) and maximum rCBV from the enhancing region of the tumor (rCBV{sub ER-Max}) were compared and correlated with survival data. Analysis was repeated after rCBVs were dichotomized into high and low values and after excluding elderly patients who did not receive postoperative chemoradiation (34.3 %). Kaplan-Meyer survival curves and parametric and semi-parametric regression tests were used for analysis. All rCBV parameters were higher in elderly compared to younger patients (p < 0.05). After adjustment for age, none were independently associated with shorter survival (p > 0.05). After rCBV dichotomization into high and low values, high rCBV in elderly was independently associated with shorter survival compared to low rCBV in elderly, or any rCBV in younger patients (p < 0.05). rCBV can be an imaging biomarker to identify a subgroup of GBM patients in the elderly with worse prognosis compared to others. (orig.)

  3. Application of dynamic susceptibility contrast-enhanced perfusion in temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Wu; Wang, Xiaoyi; Xie, Fangfang; Liao, Weihua [Dept. of Radiology, Xiangya Hospital of Central South Univ., Changsha (China)], e-mail: doctoring@sina.com

    2013-02-15

    Background: Accurately locatithe epileptogenic focus in temporal lobe epilepsy (TLE) is important in clinical practice. Single-photon emission computed tomography (SPECT) and positron-emission tomography (PET) have been widely used in the lateralization of TLE, but both have limitations. Magnetic resonance perfusion imaging can accurately and reliably reflect differences in cerebral blood flow and volume. Purpose: To investigate the diagnostic value of dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) in the lateralization of the epileptogenic focus in TLE. Material and Methods: Conventional MRI and DSC-MRI scanning was performed in 20 interictal cases of TLE and 20 healthy volunteers. The relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) of the bilateral mesial temporal lobes of the TLE cases and healthy control groups were calculated. The differences in the perfusion asymmetry indices (AIs), derived from the rCBV and rCBF of the bilateral mesial temporal lobes, were pared between the two groups. Results: In the control group, there were no statistically significant differences between the left and right sides in terms of rCBV (left 1.55 {+-} 0.32, right 1.57 {+-} 0.28) or rCBF (left 99.00 {+-} 24.61, right 100.38 {+-} 23.46) of the bilateral mesial temporal lobes. However, in the case group the ipsilateral rCBV and rCBF values (1.75 {+-} 0.64 and 96.35 {+-} 22.63, respectively) were markedly lower than those of the contralateral side (2.01 {+-} 0.79 and 108.56 {+-} 26.92; P < 0.05). Both the AI of the rCBV (AIrCBV; 13.03 {+-} 10.33) and the AI of the rCBF (AIrCBF; 11.24 {+-} 8.70) of the case group were significantly higher than that of the control group (AIrCBV 5.55 {+-} 3.74, AIrCBF 5.12 {+-} 3.48; P < 0.05). The epileptogenic foci of nine patients were correctly lateralized using the 95th percentile of the AIrCBV and AIrCBF of the control group as the normal upper limits. Conclusion: In

  4. Strategically acquired gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    Science.gov (United States)

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Mark Haacke, E

    2017-10-19

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times 3T) were used for both T1 mapping with radio frequency (RF) transmit field correction and creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases for the ten datasets compared to the single echo result of 17.5ms, and 80±36%, 59±29% and 108±37% CNR increases for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Copyright © 2017. Published by Elsevier Inc.

  5. Dynamic Susceptibility Contrast Enhanced (DSC) MRI Perfusion and Plasma Cytokine Levels in Patients after Tonic-clonic Seizures.

    Science.gov (United States)

    Filipovic, Tatjana; Popovic, Katarina Surlan; Ihan, Alojz; Vodusek, David Bozidar

    2017-09-01

    Inflammatory events in brain parenchyma and glial tissue are involved in epileptogenesis. Blood concentration of cytokines is shown to be elevated after tonic-clonic seizures. As a result of inflammation, blood-brain barrier leakage occurs. This can be documented by imaging techniques, such is dynamic susceptibility contrast enhanced (DSC) MRI perfusion. Our aim was to check for postictal brain inflammation by studying DSC MRI perfusion and plasma level of cytokines. We looked for correlations between number and type of introducing seizures, postictal plasma level of cytokines and parameters of DSC MRI perfusion. Furthermore, we looked for correlation of those parameters and course of the disease over one year follow up. We prospectively enrolled 30 patients, 8-24 hours after single or repeated tonic-clonic seizures. 25 of them had normal perfusion parameters, while 5 had hyperperfusion. Patients with hyperperfusion were tested again, 3 months later. Two of 5 had hyperperfusion also on control measurements. Number of index seizures negatively correlated with concentration of proinflammatory cytokines IL-10, IFN-ϒ and TNF-α in a whole cohort. In patients with hyperperfusion, there were significantly lower concentrations of antiinflammatory cytokine IL-4 and higher concentrations of proinflammatory TNF-a. Long lasting blood- brain barrier disruption may be crucial for epileptogenesis in selected patients.

  6. Reproducibility of dynamic contrast-enhanced MRI and dynamic susceptibility contrast MRI in the study of brain gliomas: a comparison of data obtained using different commercial software.

    Science.gov (United States)

    Conte, Gian Marco; Castellano, Antonella; Altabella, Luisa; Iadanza, Antonella; Cadioli, Marcello; Falini, Andrea; Anzalone, Nicoletta

    2017-04-01

    Dynamic susceptibility contrast MRI (DSC) and dynamic contrast-enhanced MRI (DCE) are useful tools in the diagnosis and follow-up of brain gliomas; nevertheless, both techniques leave the open issue of data reproducibility. We evaluated the reproducibility of data obtained using two different commercial software for perfusion maps calculation and analysis, as one of the potential sources of variability can be the software itself. DSC and DCE analyses from 20 patients with gliomas were tested for both the intrasoftware (as intraobserver and interobserver reproducibility) and the intersoftware reproducibility, as well as the impact of different postprocessing choices [vascular input function (VIF) selection and deconvolution algorithms] on the quantification of perfusion biomarkers plasma volume (Vp), volume transfer constant (K trans ) and rCBV. Data reproducibility was evaluated with the intraclass correlation coefficient (ICC) and Bland-Altman analysis. For all the biomarkers, the intra- and interobserver reproducibility resulted in almost perfect agreement in each software, whereas for the intersoftware reproducibility the value ranged from 0.311 to 0.577, suggesting fair to moderate agreement; Bland-Altman analysis showed high dispersion of data, thus confirming these findings. Comparisons of different VIF estimation methods for DCE biomarkers resulted in ICC of 0.636 for K trans and 0.662 for Vp; comparison of two deconvolution algorithms in DSC resulted in an ICC of 0.999. The use of single software ensures very good intraobserver and interobservers reproducibility. Caution should be taken when comparing data obtained using different software or different postprocessing within the same software, as reproducibility is not guaranteed anymore.

  7. Cerebral blood volume calculated by dynamic susceptibility contrast-enhanced perfusion MR imaging: preliminary correlation study with glioblastoma genetic profiles.

    Directory of Open Access Journals (Sweden)

    Inseon Ryoo

    Full Text Available To evaluate the usefulness of dynamic susceptibility contrast (DSC enhanced perfusion MR imaging in predicting major genetic alterations in glioblastomas.Twenty-five patients (M:F = 13∶12, mean age: 52.1±15.2 years with pathologically proven glioblastoma who underwent DSC MR imaging before surgery were included. On DSC MR imaging, the normalized relative tumor blood volume (nTBV of the enhancing solid portion of each tumor was calculated by using dedicated software (Nordic TumorEX, NordicNeuroLab, Bergen, Norway that enabled semi-automatic segmentation for each tumor. Five major glioblastoma genetic alterations (epidermal growth factor receptor (EGFR, phosphatase and tensin homologue (PTEN, Ki-67, O6-methylguanine-DNA methyltransferase (MGMT and p53 were confirmed by immunohistochemistry and analyzed for correlation with the nTBV of each tumor. Statistical analysis was performed using the unpaired Student t test, ROC (receiver operating characteristic curve analysis and Pearson correlation analysis.The nTBVs of the MGMT methylation-negative group (mean 9.5±7.5 were significantly higher than those of the MGMT methylation-positive group (mean 5.4±1.8 (p = .046. In the analysis of EGFR expression-positive group, the nTBVs of the subgroup with loss of PTEN gene expression (mean: 10.3±8.1 were also significantly higher than those of the subgroup without loss of PTEN gene expression (mean: 5.6±2.3 (p = .046. Ki-67 labeling index indicated significant positive correlation with the nTBV of the tumor (p = .01.We found that glioblastomas with aggressive genetic alterations tended to have a high nTBV in the present study. Thus, we believe that DSC-enhanced perfusion MR imaging could be helpful in predicting genetic alterations that are crucial in predicting the prognosis of and selecting tailored treatment for glioblastoma patients.

  8. Improved quantification of cerebral hemodynamics using individualized time thresholds for assessment of peak enhancement parameters derived from dynamic susceptibility contrast enhanced magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Christian Nasel

    Full Text Available Assessment of cerebral ischemia often employs dynamic susceptibility contrast enhanced magnetic resonance imaging (DSC-MRI with evaluation of various peak enhancement time parameters. All of these parameters use a single time threshold to judge the maximum tolerable peak enhancement delay that is supposed to reliably differentiate sufficient from critical perfusion. As the validity of this single threshold approach still remains unclear, in this study, (1 the definition of a threshold on an individual patient-basis, nevertheless (2 preserving the comparability of the data, was investigated.The histogram of time-to-peak (TTP values derived from DSC-MRI, the so-called TTP-distribution curve (TDC, was modeled using a double-Gaussian model in 61 patients without severe cerebrovascular disease. Particular model-based zf-scores were used to describe the arterial, parenchymal and venous bolus-transit phase as time intervals Ia,p,v. Their durations (delta Ia,p,v, were then considered as maximum TTP-delays of each phase.Mean-R2 for the model-fit was 0.967. Based on the generic zf-scores the proposed bolus transit phases could be differentiated. The Ip-interval reliably depicted the parenchymal bolus-transit phase with durations of 3.4 s-10.1 s (median = 4.3s, where an increase with age was noted (∼30 ms/year.Individual threshold-adjustment seems rational since regular bolus-transit durations in brain parenchyma obtained from the TDC overlap considerably with recommended critical TTP-thresholds of 4 s-8 s. The parenchymal transit time derived from the proposed model may be utilized to individually correct TTP-thresholds, thereby potentially improving the detection of critical perfusion.

  9. Improved Quantification of Cerebral Hemodynamics Using Individualized Time Thresholds for Assessment of Peak Enhancement Parameters Derived from Dynamic Susceptibility Contrast Enhanced Magnetic Resonance Imaging

    Science.gov (United States)

    Nasel, Christian; Kalcher, Klaudius; Boubela, Roland; Moser, Ewald

    2014-01-01

    Purpose Assessment of cerebral ischemia often employs dynamic susceptibility contrast enhanced magnetic resonance imaging (DSC-MRI) with evaluation of various peak enhancement time parameters. All of these parameters use a single time threshold to judge the maximum tolerable peak enhancement delay that is supposed to reliably differentiate sufficient from critical perfusion. As the validity of this single threshold approach still remains unclear, in this study, (1) the definition of a threshold on an individual patient-basis, nevertheless (2) preserving the comparability of the data, was investigated. Methods The histogram of time-to-peak (TTP) values derived from DSC-MRI, the so-called TTP-distribution curve (TDC), was modeled using a double-Gaussian model in 61 patients without severe cerebrovascular disease. Particular model-based zf-scores were used to describe the arterial, parenchymal and venous bolus-transit phase as time intervals Ia,p,v. Their durations (delta Ia,p,v), were then considered as maximum TTP-delays of each phase. Results Mean-R2 for the model-fit was 0.967. Based on the generic zf-scores the proposed bolus transit phases could be differentiated. The Ip-interval reliably depicted the parenchymal bolus-transit phase with durations of 3.4 s–10.1 s (median = 4.3s), where an increase with age was noted (∼30 ms/year). Conclusion Individual threshold-adjustment seems rational since regular bolus-transit durations in brain parenchyma obtained from the TDC overlap considerably with recommended critical TTP-thresholds of 4 s–8 s. The parenchymal transit time derived from the proposed model may be utilized to individually correct TTP-thresholds, thereby potentially improving the detection of critical perfusion. PMID:25521121

  10. Differentiation of brain abscesses from glioblastomas and metastatic brain tumors: comparisons of diagnostic performance of dynamic susceptibility contrast-enhanced perfusion MR imaging before and after mathematic contrast leakage correction.

    Science.gov (United States)

    Toh, Cheng Hong; Wei, Kuo-Chen; Chang, Chen-Nen; Ng, Shu-Hang; Wong, Ho-Fai; Lin, Ching-Po

    2014-01-01

    To compare the diagnostic performance of dynamic susceptibility contrast-enhanced perfusion MRI before and after mathematic contrast leakage correction in differentiating pyogenic brain abscesses from glioblastomas and/or metastatic brain tumors. Cerebral blood volume (CBV), leakage-corrected CBV and leakage coefficient K2 were measured in enhancing rims, perifocal edema and contralateral normal appearing white matter (NAWM) of 17 abscesses, 19 glioblastomas and 20 metastases, respectively. The CBV and corrected CBV were normalized by dividing the values in the enhancing rims or edema to those of contralateral NAWM. For each study group, a paired t test was used to compare the K2 of the enhancing rims or edema with those of NAWM, as well as between CBV and corrected CBV of the enhancing rims or edema. ANOVA was used to compare CBV, corrected CBV and K2 among three lesion types. The diagnostic performance of CBV and corrected CBV was assessed with receiver operating characteristic (ROC) curve analysis. The CBV and correction CBV of enhancing rim were 1.45±1.17 and 1.97±1.01 for abscesses, 3.85±2.19 and 4.39±2.33 for glioblastomas, and 2.39±0.90 and 2.97±0.78 for metastases, respectively. The CBV and corrected CBV in the enhancing rim of abscesses were significantly lower than those of glioblastomas and metastases (P = 0.001 and P = 0.007, respectively). In differentiating abscesses from glioblastomas and metastases, the AUC values of corrected CBV (0.822) were slightly higher than those of CBV (0.792). Mathematic leakage correction slightly increases the diagnostic performance of CBV in differentiating pyogenic abscesses from necrotic glioblastomas and cystic metastases. Clinically, DSC perfusion MRI may not need mathematic leakage correction in differentiating abscesses from glioblastomas and/or metastases.

  11. Cerebral blood volume analysis in glioblastomas using dynamic susceptibility contrast-enhanced perfusion MRI: a comparison of manual and semiautomatic segmentation methods.

    Directory of Open Access Journals (Sweden)

    Seung Chai Jung

    Full Text Available PURPOSE: To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV using dynamic susceptibility contrast-enhanced (DSC perfusion MR imaging in glioblastomas. MATERIALS AND METHODS: Twenty-two patients (11 male, 11 female; 27 tumors with histologically confirmed glioblastoma (WHO grade IV were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC, Bland-Altman plot, and coefficient of variation (CV were used to evaluate reproducibility. RESULTS: Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74-0.89 and CV of 20.39-36.83% in manual segmentation method, and ICC of 0.95-0.99 and CV of 8.53-16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86-0.94 and CV of 19.67-35.15% in manual segmentation method, and ICC of 0.74-1.0 and CV of 5.48-49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods. CONCLUSION: The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.

  12. Slice-accelerated gradient-echo echo planar imaging dynamic susceptibility contrast-enhanced MRI with blipped CAIPI: effect of increasing temporal resolution.

    Science.gov (United States)

    Takamura, Tomohiro; Hori, Masaaki; Kamagata, Koji; Kumamaru, Kanako K; Irie, Ryusuke; Hagiwara, Akifumi; Hamasaki, Nozomi; Aoki, Shigeki

    2018-01-01

    To assess the influence of high temporal resolution on the perfusion measurements and image quality of perfusion maps, by applying simultaneous-multi-slice acquisition (SMS) dynamic susceptibility contrast-enhanced (DSC) magnetic resonance imaging (MRI). DSC-MRI data using SMS gradient-echo echo planar imaging sequences in 10 subjects with no intracranial abnormalities were retrospectively analyzed. Three additional data sets with temporal resolution of 1.0, 1.5, and 2.0 s were created from the raw data sets of 0.5 s. Cerebral blood flow (CBF), cerebral blood volume, mean transit time (MTT), time to peak (TTP), and time to maximum tissue residue function (T max ) measurements were performed, as was visual perfusion map analysis. The perfusion parameter for temporal resolution of 0.5 s (reference) was compared with each synthesized perfusion parameter. CBF, MTT, and TTP values at temporal resolutions of 1.5 and 2.0 s differed significantly from the reference. The image quality of MTT, TTP, and T max maps deteriorated with decreasing temporal resolution. The temporal resolution of DSC-MRI influences perfusion parameters and SMS DSC-MRI provides better image quality for MTT, TTP, and T max maps.

  13. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hua-Feng [302 Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China); Chen, Zhi-Ye; Wang, Yu-Lin; Wang, Yan; Ma, Lin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); Lou, Xin [People' s Liberation Army General Hospital, Department of Radiology, Beijing (China); University of California, Department of Neurology, Los Angeles, CA (United States); Gui, Qiu-Ping [People' s Liberation Army General Hospital, Department of Pathology, Beijing (China); Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan [General Electric Healthcare (China) Co., Ltd., Beijing; Wang, Danny J.J. [University of California, Department of Neurology, Los Angeles, CA (United States)

    2015-12-15

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 x 10{sup -3} mm{sup 2}/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. (orig.)

  14. Discrimination between glioma grades II and III in suspected low-grade gliomas using dynamic contrast-enhanced and dynamic susceptibility contrast perfusion MR imaging: a histogram analysis approach

    Energy Technology Data Exchange (ETDEWEB)

    Falk, Anna; Fahlstroem, Markus; Morell, Arvid; Larsson, Elna-Marie [Uppsala University, Department of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden); Rostrup, Egill; Larsson, Henrik B.W. [University of Copenhagen, Functional Imaging Unit, Glostrup Hospital, Glostrup, Copenhagen (Denmark); Berntsson, Shala; Zetterling, Maria; Smits, Anja [Uppsala University, Department of Neuroscience, Neurology, Uppsala (Sweden)

    2014-12-15

    Perfusion magnetic resonance imaging (MRI) can be used in the pre-operative assessment of brain tumours. The aim of this prospective study was to identify the perfusion parameters from dynamic contrast-enhanced (DCE) and dynamic susceptibility contrast (DSC) perfusion imaging that could best discriminate between grade II and III gliomas. MRI (3 T) including morphological ((T2 fluid attenuated inversion recovery (FLAIR) and T1-weighted (T1W)+Gd)) and perfusion (DCE and DSC) sequences was performed in 39 patients with newly diagnosed suspected low-grade glioma after written informed consent in this review board-approved study. Regions of interests (ROIs) in tumour area were delineated on FLAIR images co-registered to DCE and DSC, respectively, in 25 patients with histopathological grade II (n = 18) and III (n = 7) gliomas. Statistical analysis of differences between grade II and grade III gliomas in histogram perfusion parameters was performed, and the areas under the curves (AUC) from the ROC analyses were evaluated. In DCE, the skewness of transfer constant (k{sub trans}) was found superior for differentiating grade II from grade III in all gliomas (AUC 0.76). In DSC, the standard deviation of relative cerebral blood flow (rCBF) was found superior for differentiating grade II from grade III gliomas (AUC 0.80). Histogram parameters from k{sub trans} (DCE) and rCBF (DSC) could most efficiently discriminate between grade II and grade III gliomas. (orig.)

  15. Contrasting Roles of the Apoplastic Aspartyl Protease APOPLASTIC, ENHANCED DISEASE SUSCEPTIBILITY1-DEPENDENT1 and LEGUME LECTIN-LIKE PROTEIN1 in Arabidopsis Systemic Acquired Resistance.

    Science.gov (United States)

    Breitenbach, Heiko H; Wenig, Marion; Wittek, Finni; Jordá, Lucia; Maldonado-Alconada, Ana M; Sarioglu, Hakan; Colby, Thomas; Knappe, Claudia; Bichlmeier, Marlies; Pabst, Elisabeth; Mackey, David; Parker, Jane E; Vlot, A Corina

    2014-06-01

    Systemic acquired resistance (SAR) is an inducible immune response that depends on ENHANCED DISEASE SUSCEPTIBILITY1 (EDS1). Here, we show that Arabidopsis (Arabidopsis thaliana) EDS1 is required for both SAR signal generation in primary infected leaves and SAR signal perception in systemic uninfected tissues. In contrast to SAR signal generation, local resistance remains intact in eds1 mutant plants in response to Pseudomonas syringae delivering the effector protein AvrRpm1. We utilized the SAR-specific phenotype of the eds1 mutant to identify new SAR regulatory proteins in plants conditionally expressing AvrRpm1. Comparative proteomic analysis of apoplast-enriched extracts from AvrRpm1-expressing wild-type and eds1 mutant plants led to the identification of 12 APOPLASTIC, EDS1-DEPENDENT (AED) proteins. The genes encoding AED1, a predicted aspartyl protease, and another AED, LEGUME LECTIN-LIKE PROTEIN1 (LLP1), were induced locally and systemically during SAR signaling and locally by salicylic acid (SA) or its functional analog, benzo 1,2,3-thiadiazole-7-carbothioic acid S-methyl ester. Because conditional overaccumulation of AED1-hemagglutinin inhibited SA-induced resistance and SAR but not local resistance, the data suggest that AED1 is part of a homeostatic feedback mechanism regulating systemic immunity. In llp1 mutant plants, SAR was compromised, whereas the local resistance that is normally associated with EDS1 and SA as well as responses to exogenous SA appeared largely unaffected. Together, these data indicate that LLP1 promotes systemic rather than local immunity, possibly in parallel with SA. Our analysis reveals new positive and negative components of SAR and reinforces the notion that SAR represents a distinct phase of plant immunity beyond local resistance. © 2014 American Society of Plant Biologists. All Rights Reserved.

  16. Differentiation of Primary Central Nervous System Lymphoma and High-Grade Glioma with Dynamic Susceptibility Contrast-Enhanced Perfusion Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Weihua Liao; Yunhai Liu; Xiaoyi Wang; Xinya Jiang; Beisha Tang; Jiasheng Fang; Changqing Chen; Zhongliang Hu (Dept.s of Radiology, Neurology, Neurosurgery, and Pathology, Xiangya Hospital, Central South Univ., Changsha, Hunan (China))

    2009-02-15

    Background: Preoperative differentiation of primary central nervous system lymphomas (PCNSLs) from other tumors is important for presurgical staging, intraoperative management, and postoperative treatment. Dynamic susceptibility contrast-enhanced perfusion magnetic resonance imaging (DSC perfusion MRI) can provide in vivo assessment of the microvasculature in intracranial mass lesions. Purpose: To determine the utility of DSC perfusion MRI in the differentiation of PCNSLs and high-grade gliomas, as well as their pathological and physiological differences. Material and Methods: Nine patients with pathologically proven PCNSLs and 11 patients with high-grade gliomas were examined using a 1.5T MRI scanner. DSC perfusion MRI was performed by gradient-echo echo-planar imaging (GE-EPI). The maximum rCBV ratio, the signal intensity-time curves, and the percentage of signal intensity recovery were obtained. The maximum relative cerebral blood volume (rCBV) ratio and the percentage of signal intensity recovery of PCNSLs were compared with those of high-grade gliomas by using Student's t test. Microvessel density (MVD) was evaluated using immunohistochemical staining of surgical specimens with anti-CD34, and MVDs of the two tumor groups were compared by using Student's t test. Results: The maximum rCBV ratio of primary intracranial lymphomas was 1.72+-0.59, while that of high-grade gliomas was 4.86+-2.18. PCNSLs tended to have relatively low perfusion compared to high-grade gliomas (P=0.001), and the MVD labeled by anti-CD34 of PCNSLs was much lower than that of gliomas (P<0.001). The signal intensity-time curve of primary intracranial lymphomas was different from that of high-grade gliomas. The percentage of signal intensity recovery was significantly greater in PCNSLs compared with that of high-grade gliomas (P<0.001). Conclusion: The difference in DSC perfusion MRI characteristics between PCNSLs and high-grade gliomas is determined by their different

  17. Astrocytic tumour grading: a comparative study of three-dimensional pseudocontinuous arterial spin labelling, dynamic susceptibility contrast-enhanced perfusion-weighted imaging, and diffusion-weighted imaging.

    Science.gov (United States)

    Xiao, Hua-Feng; Chen, Zhi-Ye; Lou, Xin; Wang, Yu-Lin; Gui, Qiu-Ping; Wang, Yan; Shi, Kai-Ning; Zhou, Zhen-Yu; Zheng, Dan-Dan; Wang, Danny J J; Ma, Lin

    2015-12-01

    We hypothesized that three-dimensional pseudocontinuous arterial spin labelling (pCASL) may have similar efficacy in astrocytic tumour grading as dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI), and the grading accuracy may be further improved when combined with apparent diffusion coefficient (ADC) values. Forty-three patients with astrocytic tumours were studied using diffusion weighted imaging (DWI), pCASL, and DSC-PWI. Histograms of ADC and normalized tumour cerebral blood flow values (nCBF on pCASL and nrCBF on DSC-PWI) were measured and analyzed. The mean 10 % ADC value was the DWI parameter that provided the best differentiation between low-grade astrocytoma (LGA) and high-grade astrocytoma (HGA). The nCBF and nrCBF (1.810 ± 0.979 and 2.070 ± 1.048) in LGA were significantly lower than those (4.505 ± 2.270 and 5.922 ± 2.630) in HGA. For differentiation between LGA and HGA, the cutoff values of 0.764 × 10(-3) mm(2)/s for mean 10 % ADC, 2.374 for nCBF, and 3.464 for nrCBF provided the optimal accuracy (74.4 %, 86.1 %, and 88.6 %, respectively). Combining the ADC values with nCBF or nrCBF could further improve the grading accuracy to 97.7 % or 95.3 %, respectively. pCASL is an alternative to DSC-PWI for astrocytic tumour grading. The combination of DWI and contrast-free pCASL offers a valuable choice in patients with risk factors. • pCASL shows positive correlation with DSC-PWI in astrocytic tumour grading. • ADC values based on ADC histograms can be an objective method. • Combination of DWI and pCASL or DSC-PWI can improve grading accuracy.

  18. The role of dynamic susceptibility contrast-enhanced perfusion MR imaging in differentiating between infectious and neoplastic focal brain lesions: results from a cohort of 100 consecutive patients.

    Directory of Open Access Journals (Sweden)

    Valdeci Hélio Floriano

    Full Text Available BACKGROUND AND PURPOSE: Differentiating between infectious and neoplastic focal brain lesions that are detected by conventional structural magnetic resonance imaging (MRI may be a challenge in routine practice. Brain perfusion-weighted MRI (PWI may be employed as a complementary non-invasive tool, providing relevant data on hemodynamic parameters, such as the degree of angiogenesis of lesions. We aimed to employ dynamic susceptibility contrast-enhanced perfusion MR imaging (DSC-MRI to differentiate between infectious and neoplastic brain lesions by investigating brain microcirculation changes. MATERIALS AND METHODS: DSC-MRI perfusion studies of one hundred consecutive patients with non-cortical neoplastic (n = 54 and infectious (n = 46 lesions were retrospectively assessed. MRI examinations were performed using a 1.5-T scanner. A preload of paramagnetic contrast agent (gadolinium was administered 30 seconds before acquisition of dynamic images, followed by a standard dose 10 seconds after starting imaging acquisitions. The relative cerebral blood volume (rCBV values were determined by calculating the regional cerebral blood volume in the solid areas of lesions, normalized to that of the contralateral normal-appearing white matter. Discriminant analyses were performed to determine the cutoff point of rCBV values that would allow the differentiation of neoplastic from infectious lesions and to assess the corresponding diagnostic performance of rCBV when using this cutoff value. RESULTS: Neoplastic lesions had higher rCBV values (4.28±2.11 than infectious lesions (0.63±0.49 (p<0.001. When using an rCBV value <1.3 as the parameter to define infectious lesions, the sensitivity of the method was 97.8% and the specificity was 92.6%, with a positive predictive value of 91.8%, a negative predictive value of 98.0%, and an accuracy of 95.0%. CONCLUSION: PWI is a useful complementary tool in distinguishing between infectious and neoplastic brain

  19. Fuzzy-Contextual Contrast Enhancement.

    Science.gov (United States)

    Parihar, Anil; Verma, Om; Khanna, Chintan

    2017-02-08

    This paper presents contrast enhancement algorithms based on fuzzy contextual information of the images. We introduce fuzzy similarity index and fuzzy contrast factor to capture the neighborhood characteristics of a pixel. A new histogram, using fuzzy contrast factor of each pixel is developed, and termed as the fuzzy dissimilarity histogram (FDH). A cumulative distribution function (CDF) is formed with normalized values of FDH and used as a transfer function to obtain the contrast enhanced image. The algorithm gives good contrast enhancement and preserves the natural characteristic of the image. In order to develop a contextual intensity transfer function, we introduce a fuzzy membership function based on fuzzy similarity index and coefficient of variation of the image. The contextual intensity transfer function is designed using the fuzzy membership function to achieve final contrast enhanced image. The overall algorithm is referred as the fuzzy contextual contrast-enhancement (FCCE) algorithm. The proposed algorithms are compared with conventional and state-of-art contrast enhancement algorithms. The quantitative and visual assessment of the results is performed. The results of quantitative measures are statistically analyzed using t-test. The exhaustive experimentation and analysis show the proposed algorithm efficiently enhances contrast and yields in natural visual quality images.

  20. Application of histogram analysis for the evaluation of vascular permeability in glioma by the K2 parameter obtained with the dynamic susceptibility contrast method: Comparisons with Ktrans obtained with the dynamic contrast enhance method and cerebral blood volume.

    Science.gov (United States)

    Taoka, Toshiaki; Kawai, Hisashi; Nakane, Toshiki; Hori, Saeka; Ochi, Tomoko; Miyasaka, Toshiteru; Sakamoto, Masahiko; Kichikawa, Kimihiko; Naganawa, Shinji

    2016-09-01

    The "K2" value is a factor that represents the vascular permeability of tumors and can be calculated from datasets obtained with the dynamic susceptibility contrast (DSC) method. The purpose of the current study was to correlate K2 with Ktrans, which is a well-established permeability parameter obtained with the dynamic contrast enhance (DCE) method, and determine the usefulness of K2 for glioma grading with histogram analysis. The subjects were 22 glioma patients (Grade II: 5, III: 6, IV: 11) who underwent DSC studies, including eight patients in which both DSC and DCE studies were performed on separate days within 10days. We performed histogram analysis of regions of interest of the tumors and acquired 20th percentile values for leakage-corrected cerebral blood volume (rCBV20%ile), K2 (K220%ile), and for patients who underwent a DCE study, Ktrans (Ktrans20%ile). We evaluated the correlation between K220%ile and Ktrans20%ile and the statistical difference between rCBV20%ile and K220%ile. We found a statistically significant correlation between K220%ile and Ktrans20%ile (r=0.717, p<0.05). rCBV20%ile showed a significant difference between Grades II and III and between Grades II and IV, whereas K220%ile showed a statistically significant (p<0.05) difference between Grades II and IV and between Grades III and IV. The K2 value calculated from the DSC dataset, which can be obtained with a short acquisition time, showed a correlation with Ktrans obtained with the DCE method and may be useful for glioma grading when analyzed with histogram analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    -state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged......In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast...... MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic...

  2. Contrast-enhanced digital mammography.

    Science.gov (United States)

    Jochelson, Maxine

    2014-05-01

    Mammography is the only technology documented to reduce breast cancer mortality. Its sensitivity, however, is 75% to 80% at best and reduced to 30% to 50% in women with dense breasts. MR imaging is a sensitive modality for the detection of breast cancer but cannot be used in all patients. Its sensitivity is due in large part to its ability to detect enhancement of tumor vascularity so cancers can be detected before a mass is present. Contrast-enhanced dual-energy mammography uses the same capability of vascular enhancement and has been demonstrated to be more sensitive than routine mammography. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging....

  4. Commercialization of vein contrast enhancement

    Science.gov (United States)

    Lovhoiden, Gunnar; Deshmukh, Harshal; Vrancken, Carlos; Zhang, Yong; Zeman, Herbert D.; Weinberg, Devin

    2003-07-01

    An ongoing clinical study of an experimental infrared (IR) device, the Vein Contrast Enhancer (VCE) that visualizes surface veins for medical access, indicates that a commercial device with the performance of the existing VCE would have significant clinical utility for even a very skilled phlebotomist. A proof-of-principle prototype VCE device has now been designed and constructed that captures IR images of surface veins with a commercial CCD camera, transfers the images to a PC for real-time software image processing to enhance the vein contrast, and projects the enhanced images back onto the skin with a modified commercial LCD projector. The camera and projector are mounted on precision slides allowing for precise mechanical alignment of the two optical axes and for measuring the effects of axes misalignment. Precision alignment of the captured and projected images over the entire field-of-view is accomplished electronically by software adjustments of the translation, scaling, and rotation of the enhanced images before they are projected back onto the skin. This proof-of-principle prototype will be clinically tested and the experience gained will lead to the development of a commercial device, OnTarget!, that is compact, easy to use, and will visualize accessible veins in almost all subjects needing venipuncture.

  5. Measurement of perfusion using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI in neurooncology. Physical basics and clinical applications; Perfusionsmessung mit der T2*-Kontrastmitteldynamik in der Neuroonkologie. Physikalische Grundlagen und klinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.-A.; Giesel, F.L.; Kauczor, H.-U.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Radiologie; Risse, F.; Schad, L.R. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Medizinische Physik in der Radiologie

    2005-07-01

    Perfusion imaging in the central nervous system (CNS) is mostly performed using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI. The first-pass of a contrast bolus in brain tissue is monitored by a series of T2*-weighted MR images. The susceptibility effect of the paramagnetic contrast agent leads to a signal loss that can be converted, using the principles of the indicator dilution theory, into an increase of the contrast agent concentration. From these data, parameter maps of cerebral blood volume (CBV) and flow (CBF) can be derived. Regional CBF and CBV values can be obtained by region-of-interest analysis. This review article describes physical basics of DSC MRI and summarizes the literature of DSC MRI in neurooncological issues. Studies, all with relatively limited patient numbers, report that DSC MRI is useful in the preoperative diagnosis of gliomas, CNS-lymphomas, and solitary metastases, as well as in the differentiation of these neoplastic lesions from infections and tumor-like manifestations of demyelinating disease. Additionally, DSC MRI is suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy. After therapy, DSC MRI helps better assessing the tumor response to therapy, residual tumor after therapy, and possible treatment failure and therapy-related complications, such as radiation necrosis. The preliminary results show that DSC MRI is a diagnostic tool depicting regional variations in microvasculature of normal and diseased brains. (orig.) [German] Die MRT-Perfusionsmessungen im Zentralnervensystem (ZNS) werden derzeit hauptsaechlich mit der kontrastmittelverstaerkten T2*-Dynamik durchgefuehrt, die die Passage eines schnellen Kontrastmittelbolus mit einer Serie von T2*-gewichteten MRT-Aufnahmen verfolgt und charakterisiert. Dabei wird der Signalabfall, bedingt durch den Suszeptibilitaetseffekt des paramagnetischen Kontrastmittels, mittels geeigneter

  6. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Server, Andres; Nakstad, Per H. [Oslo University Hospital-Ullevaal, Section of Neuroradiology, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Oslo (Norway); Orheim, Tone E.D. [Oslo University Hospital, Interventional Centre, Oslo (Norway); Graff, Bjoern A. [Oslo University Hospital-Ullevaal, Department of Radiology and Nuclear Medicine, Oslo (Norway); Josefsen, Roger [Oslo University Hospital-Ullevaal, Department of Neurosurgery, Oslo (Norway); Kumar, Theresa [Oslo University Hospital-Ullevaal, Department of Pathology, Oslo (Norway)

    2011-05-15

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  7. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...... and monitor the efficacy of antiangiogenic agents, to assist targeted drug delivery and allow molecular imaging....

  8. Dynamic contrast enhanced MRI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alonzi, Roberto [Marie Curie Research Wing, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom)], E-mail: robertoalonzi@btinternet.com; Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom); Synarc Inc. 575 Market Street, San Francisco, CA 94105 (United States)], E-mail: anwar.padhani@paulstrickland-scannercentre.org.uk; Allen, Clare [Department of Imaging, University College Hospital, London, 235 Euston Road, NW1 2BU (United Kingdom)], E-mail: clare.allen@uclh.nhs.uk

    2007-09-15

    Angiogenesis is an integral part of benign prostatic hyperplasia (BPH), is associated with prostatic intraepithelial neoplasia (PIN) and is key to the growth and for metastasis of prostate cancer. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) using small molecular weight gadolinium chelates enables non-invasive imaging characterization of tissue vascularity. Depending on the technique used, data reflecting tissue perfusion, microvessel permeability surface area product, and extracellular leakage space can be obtained. Two dynamic MRI techniques (T{sub 2}*-weighted or susceptibility based and T{sub 1}-weighted or relaxivity enhanced methods) for prostate gland evaluations are discussed in this review with reference to biological basis of observations, data acquisition and analysis methods, technical limitations and validation. Established clinical roles of T{sub 1}-weighted imaging evaluations will be discussed including lesion detection and localisation, for tumour staging and for the detection of suspected tumour recurrence. Limitations include inadequate lesion characterisation particularly differentiating prostatitis from cancer, and in distinguishing between BPH and central gland tumours.

  9. Contrast enhancement versus vasculature of uterine tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kormano, M.; Kiilholma, P.; Groenroos, M.

    1984-05-01

    The relative contrast enhancement of normal myometrium and small or medium size uterine fibroids and clinical stage I endometrial carcinomas were correlated to their microangiographically demonstrable vascularity. In four cases small uterine fibroids showed contrast enhancement equal to normal myometrium, independent of their vascularity in microangiography. In five, endometrial carcinomas contrast enhancement was always below that of the surrounding myometrium in CT. Intratumour vasculature showed great variability in microangiography. No correlation between the topographic variations in the arrangement or density of tumour blood vessels and the degree of contrast enhancement was found. Contrast enhancement of small uterine fibroids was greater than that of small adenocarcinomas. More contrast material accumulates into the extravascular space of the smooth muscle tissue of the fibroid than into the extravascular space of endometrial carcinoma.

  10. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  11. Stable spline deconvolution for dynamic susceptibility contrast MRI.

    Science.gov (United States)

    Peruzzo, Denis; Castellaro, Marco; Pillonetto, Gianluigi; Bertoldo, Alessandra

    2017-11-01

    To present the stable spline (SS) deconvolution method for the quantification of the cerebral blood flow (CBF) from dynamic susceptibility contrast MRI. The SS method was compared with both the block-circulant singular value decomposition (oSVD) and nonlinear stochastic regularization (NSR) methods. oSVD is one of the most popular deconvolution methods in dynamic susceptibility contrast MRI (DSC-MRI). NSR is an alternative approach that we proposed previously. The three methods were compared using simulated data and two clinical data sets. The SS method correctly reconstructed the dispersed residue function and its peak in presence of dispersion, regardless of the delay. In absence of dispersion, SS performs similarly to oSVD and does not correctly reconstruct the residue function and its peak. SS and NSR better differentiate healthy and pathologic CBF values compared with oSVD in all simulated conditions. Using acquired data, SS and NSR provide more clinically plausible and physiological estimates of the residue function and CBF maps compared with oSVD. The SS method overcomes some of the limitations of oSVD, such as unphysiological estimates of the residue function and NSR, the latter of which is too computationally expensive to be applied to large data sets. Thus, the SS method is a valuable alternative for CBF quantification using DSC-MRI data. Magn Reson Med 78:1801-1811, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Contrast-enhanced peripheral MRA. Technique and contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Yousef W. [Dept. of Radiology, Copenhagen Univ. Hospital Bispebjerg, Bispebjerg (Denmark)], e-mail: ywnielsen@gmail.com; Thomsen, Henrik S. [Dept. of Diagnostic Radiology, Copenhagen Univ. Hospital Herlev, Herlev (Denmark)

    2012-09-15

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  13. Quantitative contrast-enhanced mammography for contrast medium kinetics studies.

    Science.gov (United States)

    Arvanitis, C D; Speller, R

    2009-10-21

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm(-2) has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm(-2) within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  14. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  15. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, Francisco Jose [Departamento de Ciencia y Tecnologia de Materiales y Fluidos, Universidad de Zaragoza, 50018 Zaragoza (Spain) and Instituto de Nanociencia de Aragon, Universidad de Zaragoza, 50009 Zaragoza (Spain)]. E-mail: osoro@unizar.es; Gutierrez, Lucia [Departamento de Ciencia y Tecnologia de Materiales y Fluidos, Universidad de Zaragoza, 50018 Zaragoza (Spain); Rosa Abadia, Ana [Dept. Farmacologia y Fisiologia, Universidad de Zaragoza, 50013 Zaragoza (Spain); Soledad Romero, Maria [Dept. Medicina y Psiquiatria, Universidad de Zaragoza, 50009 Zaragoza (Spain); Lopez, Antonio [CNAM - Zaragoza, 50009 Zaragoza (Spain); Jesus Munoz, Maria [Dept. Farmacologia y Fisiologia, Universidad de Zaragoza, 50013 Zaragoza (Spain)

    2007-04-15

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem{sup (R)}), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers.

  16. Evaluation of contrast-enhanced digital mammography.

    Science.gov (United States)

    Diekmann, Felix; Freyer, Martin; Diekmann, Susanne; Fallenberg, Eva M; Fischer, Thomas; Bick, Ulrich; Pöllinger, Alexander

    2011-04-01

    The goal of this prospective study was to evaluate the possible diagnostic benefits of contrast-enhanced digital mammography (CEDM) over conventional mammography. Our analysis included data from 70 patients with a total of 80 lesions (30 malignant and 50 benign). A series of contrast-enhanced images was acquired from each patient using a modified imaging system (GE Senographe 2000D with copper filter) suitable for displaying iodine contrast medium. After the mask image had been taken, the contrast medium was administered using a dosage of 1ml/kg body weight at a rate of 4ml/s. Three contrast-enhanced images in the cranio-caudal projection plane were then captured at intervals of 60s. The mask image was logarithmically subtracted from the contrast-enhanced images. We performed a ROC analysis of diagnostic quality with three readers. On average, 5.66 more malignant lesions were detected with the addition of digital dynamic contrast mammography versus conventional mammography alone. The sensitivity was increased from an average of 0.43 in conventional mammography to an average of 0.62 with contrast mammography. Even in dense breast parenchyma, the sensitivity increased from an average of 0.35-0.59. In the multi-reader-ROC analyses of all readers, the differences in the AUC with p=0.02 (BI-RADS) proved statistically significant in all cases. The Wilcoxon test showed that Readers I and II primarily used the CEDM to upgrade enhancing lesions to a higher BI-RADS category or a higher probability of malignancy. These two readers benefited most from the CEDM in the ROC analysis. Overall, we conclude that the addition of dynamic digital subtraction mammography to conventional mammography can significantly improve diagnostic quality. The increased sensitivity is particularly pronounced in the case of dense breast tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Perceptual Contrast Enhancement with Dynamic Range Adjustment

    Science.gov (United States)

    Zhang, Hong; Li, Yuecheng; Chen, Hao; Yuan, Ding; Sun, Mingui

    2013-01-01

    Recent years, although great efforts have been made to improve its performance, few Histogram equalization (HE) methods take human visual perception (HVP) into account explicitly. The human visual system (HVS) is more sensitive to edges than brightness. This paper proposes to take use of this nature intuitively and develops a perceptual contrast enhancement approach with dynamic range adjustment through histogram modification. The use of perceptual contrast connects the image enhancement problem with the HVS. To pre-condition the input image before the HE procedure is implemented, a perceptual contrast map (PCM) is constructed based on the modified Difference of Gaussian (DOG) algorithm. As a result, the contrast of the image is sharpened and high frequency noise is suppressed. A modified Clipped Histogram Equalization (CHE) is also developed which improves visual quality by automatically detecting the dynamic range of the image with improved perceptual contrast. Experimental results show that the new HE algorithm outperforms several state-of-the-art algorithms in improving perceptual contrast and enhancing details. In addition, the new algorithm is simple to implement, making it suitable for real-time applications. PMID:24339452

  18. Post-traumatic contrast enhancing brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun [Eulji Hospital, Eulji University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  19. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Renal oncocytoma: contrast-enhanced sonographic features.

    Science.gov (United States)

    Wu, Ying; Du, Lianfang; Li, Fan; Zhang, Huiping; Cai, Yingyu; Jia, Xiao

    2013-03-01

    The purpose of this study was to illustrate the features of renal oncocytoma on contrast-enhanced sonography. Five cases of surgical pathologically proven renal oncocytoma were retrospectively reviewed and analyzed in this study. The 5 patients studied included 3 men and 2 women with a mean age of 52.3 years (range, 32-66 years). All patients underwent conventional and contrast-enhanced sonographic examinations before surgery. The sonographic features, enhancement pattern, and dynamic perfusion change of the tumors and renal parenchyma in vascular phases were evaluated and compared to computed tomography. On grayscale sonography, renal oncocytomas appeared as solitary hypoechoic or isoechoic masses originating from the renal cortex measuring 2 to 6 cm with a well-defined margin. Color Doppler flow imaging showed rich blood flow signals in the periphery and striplike blood flow signals within the masses. On contrast-enhanced sonography, the features of these tumors included early enhancement, hyperenhancement, and fast wash-out compared to the adjacent renal cortex. There were irregular nonenhanced areas seen in the center of the masses (n = 3) and nonenhanced thin rims seen in the periphery (n = 5). Macroscopically, the well-marginated tumors were yellowish brown with a tender texture and were located in the renal cortex. Central irregularly shaped fibrous scars were seen in 3 tumors, consistent with nonenhanced areas on contrast-enhanced imaging. Contrast-enhanced sonography can provide valuable hemodynamic information on renal oncocytoma, which may help in making a differential diagnosis of this benign renal tumor in clinical practice.

  1. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  2. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  3. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  4. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China)

    2010-08-15

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  5. Dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  6. Dynamic Contrast-Enhanced Digital Breast Tomosynthesis

    Science.gov (United States)

    2013-03-01

    500 or secretions due to pathological activity and can be precursors to breast cancers such as ductal carcinoma22, 23. Breast microcalcifications ... Breast Cancer Screening. Am J Med, in press. 650 2Gilles R, Meunier M, Lucidarme O, et al. (1996) Clustered breast microcalcifications : Evaluation... Breast Cancer , contrast-enhanced imaging, digital breast tomosynthesis, dynamic imaging, x-ray imaging 15. Number of Pages (count all pages

  7. Contrast-enhanced and targeted ultrasound

    Science.gov (United States)

    Postema, Michiel; Gilja, Odd Helge

    2011-01-01

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested. PMID:21218081

  8. Contrast-enhanced and targeted ultrasound.

    Science.gov (United States)

    Postema, Michiel; Gilja, Odd Helge

    2011-01-07

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested.

  9. Fast mutual-information-based contrast enhancement

    Science.gov (United States)

    Cao, Gang; Yu, Lifang; Tian, Huawei; Huang, Xianglin; Wang, Yongbin

    2017-07-01

    Recently, T. Celik proposed an effective image contrast enhancement (CE) method based on spatial mutual information and PageRank (SMIRANK). According to the state-of-the-art evaluation criteria, it achieves the best visual enhancement quality among existing global CE methods. However, SMIRANK runs much slower than the other counterparts, such as histogram equalization (HE) and adaptive gamma correction. Low computational complexity is also required for good CE algorithms. In this paper, we novelly propose a fast SMIRANK algorithm, called FastSMIRANK. It integrates both spatial and gray-level downsampling into the generation of pixel value mapping function. Moreover, the computation of rank vectors is speeded up by replacing PageRank with a simple yet efficient row-based operation of mutual information matrix. Extensive experimental results show that the proposed FastSMIRANK could accelerate the processing speed of SMIRANK by about 20 times, and is even faster than HE. Comparable enhancement quality is preserved simultaneously.

  10. Contrast enhancement for images in turbid water.

    Science.gov (United States)

    Lu, Huimin; Li, Yujie; Zhang, Lifeng; Serikawa, Seiichi

    2015-05-01

    Absorption, scattering, and color distortion are three major degradation factors in underwater optical imaging. Light rays are absorbed while passing through water, and absorption rates depend on the wavelength of the light. Scattering is caused by large suspended particles, which are always observed in an underwater environment. Color distortion occurs because the attenuation ratio is inversely proportional to the wavelength of light when light passes through a unit length in water. Consequently, underwater images are dark, low contrast, and dominated by a bluish tone. In this paper, we propose a novel underwater imaging model that compensates for the attenuation discrepancy along the propagation path. In addition, we develop a robust color lines-based ambient light estimator and a locally adaptive filtering algorithm for enhancing underwater images in shallow oceans. Furthermore, we propose a spectral characteristic-based color correction algorithm to recover the distorted color. The enhanced images have a reasonable noise level after the illumination compensation in the dark regions, and demonstrate an improved global contrast by which the finest details and edges are enhanced significantly.

  11. Contrast induced nephropathy following intravenous contrast enhanced computed tomography

    NARCIS (Netherlands)

    Moos, S.I.

    2015-01-01

    Contrast induced nephropathy (CIN) is often described as an acute increase in serum creatinine following intravascular contrast medium administration. CIN is associated with adverse events such as permanent renal failure, increased risk for renal replacement therapy and death. To prevent the above

  12. Osteoblastic Metastases Mimickers on Contrast Enhanced CT

    Directory of Open Access Journals (Sweden)

    Fahad Al-Lhedan

    2017-01-01

    Full Text Available Secondary osseous involvement in lymphoma is more common compared to primary bone lymphoma. The finding of osseous lesion can be incidentally discovered during the course of the disease. However, osseous metastases are infrequently silent. Detection of osseous metastases is crucial for accurate staging and optimal treatment planning of lymphoma. The aim of imaging is to identify the presence and extent of osseous disease and to assess for possible complications such as pathological fracture of the load-bearing bones and cord compression if the lesion is spinal. We are presenting two patients with treated lymphoma who were in complete remission. On routine follow-up contrast enhanced CT, there were new osteoblastic lesions in the spine worrisome for metastases. Additional studies were performed for further evaluation of both of them which did not demonstrate any corresponding suspicious osseous lesion. The patients have a prior history of chronic venous occlusive thrombosis that resulted in collaterals formation. Contrast enhancement of the vertebral body marrow secondary to collaterals formation and venous flow through the vertebral venous plexus can mimic the appearance of spinal osteoblastic metastases.

  13. Nonlinear contrast enhancement on subtraction images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keon Il; Jin, Yeun Hwa [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Wonkwang University, Yongin (Korea, Republic of)

    1997-08-15

    This study was performed to demonstrate the effect of linear or nonlinear contrast enhancement on subtraction images. Three different textures were radiographed on dental film. The first radiograph was taken without the presence of an object. The second, which showed trabucular bone, was taken of the molar area of a human. the third radiograph was taken of the coronal part of molars. Each film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-3510AF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh LC III computer(Apple Computer, Charlotte, N.C.). This resulted in three pairs of images, including different textures-plain, bone and enamel. Digital regular, linearly and nonlinearly enhanced subtraction was performed. Computer software was used to simulate lesions in the shape of a 2D-Gaussian curve on each of a pair of images. The each subtraction images were presented in a random sequence to two groups of 10 observers(students and dentists). ROC analysis was used to compare observer performance. The following results were obtained; 1. All of LCE subtraction, equalized subtraction and regular subtraction images of plain texture were diagnosed the best by far. 2. The data revealed a significant LCE effect in both the student group and the expert group. 3. Clinical expertise was a helpful factor for the observers in this study.

  14. Ultrafast 3D spin-echo acquisition improves Gadolinium-enhanced MRI signal contrast enhancement

    Science.gov (United States)

    Han, S. H.; Cho, F. H.; Song, Y. K.; Paulsen, J.; Song, Y. Q.; Kim, Y. R.; Kim, J. K.; Cho, G.; Cho, H.

    2014-01-01

    Long scan times of 3D volumetric MR acquisitions usually necessitate ultrafast in vivo gradient-echo acquisitions, which are intrinsically susceptible to magnetic field inhomogeneities. This is especially problematic for contrast-enhanced (CE)-MRI applications, where non-negligible T2* effect of contrast agent deteriorates the positive signal contrast and limits the available range of MR acquisition parameters and injection doses. To overcome these shortcomings without degrading temporal resolution, ultrafast spin-echo acquisitions were implemented. Specifically, a multiplicative acceleration factor from multiple spin echoes (×32) and compressed sensing (CS) sampling (×8) allowed highly-accelerated 3D Multiple-Modulation-Multiple-Echo (MMME) acquisition. At the same time, the CE-MRI of kidney with Gd-DOTA showed significantly improved signal enhancement for CS-MMME acquisitions (×7) over that of corresponding FLASH acquisitions (×2). Increased positive contrast enhancement and highly accelerated acquisition of extended volume with reduced RF irradiations will be beneficial for oncological and nephrological applications, in which the accurate in vivo 3D quantification of contrast agent concentration is necessary with high temporal resolution. PMID:24863102

  15. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance.

    Science.gov (United States)

    Hobbs, Max M; Taylor, Donna B; Buzynski, Sebastian; Peake, Rachel E

    2015-06-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  16. Lesion Contrast Enhancement in Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Stetson, Paul F.; Sommer, F.G.; Macovski, A.

    1997-01-01

    Methods for improving the contrast-to-noise ratio (CNR) of low-contrast lesions in medical ultrasound imaging are described. Differences in the frequency spectra and amplitude distributions of the lesion and its surroundings can be used to increase the CNR of the lesion relative to the background....... Automated graylevel mapping is used in combination with a contrast-weighted form of frequency-diversity speckle reduction. In clinical studies, the techniques have yielded mean CNR improvements of 3.2 dB above ordinary frequency-diversity imaging and 5.6 dB over sharper conventional images, with no post...

  17. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  18. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images

    OpenAIRE

    Suneet Gupta; Rabins Porwal

    2016-01-01

    Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests...

  19. Non-contrast-enhanced magnetic resonance angiography: techniques and applications.

    Science.gov (United States)

    Blankholm, Anne Dorte; Ringgaard, Steffen

    2012-01-01

    Non-contrast-enhanced magnetic resonance angiography has gained renewed interest since the discovery of the association between gadolinium-based contrast agents and nephrogenic systemic fibrosis. The following article is an overview of the different magnetic resonance angiography sequences, the technical possibilities and new developments. Clinical options and recent advancements will be highlighted, and recommendations for non-contrast-enhanced magnetic resonance angiography techniques in different anatomical regions will be given. Furthermore, the authors seek to predict the future of non-contrast-enhanced magnetic resonance angiography, with special focus on patients at risk.

  20. Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience1

    Science.gov (United States)

    Prionas, Nicolas D.; Ray, Shonket; Huang, Shih-Ying; Beckett, Laurel A.; Monsky, Wayne L.; Boone, John M.

    2010-01-01

    Purpose: To quantify contrast material enhancement of breast lesions scanned with dedicated breast computed tomography (CT) and to compare their conspicuity with that at unenhanced breast CT and mammography. Materials and Methods: Approval of the institutional review board and the Radiation Use Committee and written informed consent were obtained for this HIPAA-compliant study. Between September 2006 and April 2009, 46 women (mean age, 53.2 years; age range, 35–72 years) with Breast Imaging Reporting and Data System category 4 or 5 lesions underwent unenhanced breast CT and contrast material–enhanced breast CT before biopsy. Two radiologists independently scored lesion conspicuity for contrast-enhanced breast CT versus mammography and for contrast-enhanced breast CT versus unenhanced breast CT. Mean lesion voxel intensity was measured in Hounsfield units and normalized to adipose tissue intensity on manually segmented images obtained before and after administration of contrast material. Regression models focused on conspicuity and quantified enhancement were used to estimate the effect of pathologic diagnosis (benign vs malignant), lesion type (mass vs calcifications), breast density, and interradiologist variability. Results: Fifty-four lesions (25 benign, 29 malignant) in 46 subjects were analyzed. Malignant lesions were seen significantly better at contrast-enhanced breast CT than at unenhanced breast CT (P mammography (P contrast-enhanced breast CT than at unenhanced breast CT (P contrast-enhanced breast CT and mammography. Malignant lesions enhanced 55.9 HU ± 4.0 (standard error), whereas benign lesions enhanced 17.6 HU ± 6.1 (P contrast-enhanced breast CT. Quantifying lesion enhancement may aid in the detection and diagnosis of breast cancer. © RSNA, 2010 PMID:20720067

  1. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  2. Contrasting patterns of coral bleaching susceptibility in 2010 suggest an adaptive response to thermal stress.

    Science.gov (United States)

    Guest, James R; Baird, Andrew H; Maynard, Jeffrey A; Muttaqin, Efin; Edwards, Alasdair J; Campbell, Stuart J; Yewdall, Katie; Affendi, Yang Amri; Chou, Loke Ming

    2012-01-01

    Coral bleaching events vary in severity, however, to date, the hierarchy of susceptibility to bleaching among coral taxa has been consistent over a broad geographic range and among bleaching episodes. Here we examine the extent of spatial and temporal variation in thermal tolerance among scleractinian coral taxa and between locations during the 2010 thermally induced, large-scale bleaching event in South East Asia. Surveys to estimate the bleaching and mortality indices of coral genera were carried out at three locations with contrasting thermal and bleaching histories. Despite the magnitude of thermal stress being similar among locations in 2010, there was a remarkable contrast in the patterns of bleaching susceptibility. Comparisons of bleaching susceptibility within coral taxa and among locations revealed no significant differences between locations with similar thermal histories, but significant differences between locations with contrasting thermal histories (Friedman = 34.97; pBleaching was much less severe at locations that bleached during 1998, that had greater historical temperature variability and lower rates of warming. Remarkably, Acropora and Pocillopora, taxa that are typically highly susceptible, although among the most susceptible in Pulau Weh (Sumatra, Indonesia) where respectively, 94% and 87% of colonies died, were among the least susceptible in Singapore, where only 5% and 12% of colonies died. The pattern of susceptibility among coral genera documented here is unprecedented. A parsimonious explanation for these results is that coral populations that bleached during the last major warming event in 1998 have adapted and/or acclimatised to thermal stress. These data also lend support to the hypothesis that corals in regions subject to more variable temperature regimes are more resistant to thermal stress than those in less variable environments.

  3. CONTRAST ENHANCED SPECTRAL MAMMOGRAPHY (CESM (REVIEW

    Directory of Open Access Journals (Sweden)

    N. I. Rozhkova

    2015-01-01

    Full Text Available The problem of early diagnosis of a breast cancer is extremely actual. Growth of incidence at women from 19 to 39 years increased for 34% over the last 10 years. It defines need of acceleration of development and deployment of the latest technologies of identification of the earliest symptoms of diseases. The x-ray mammography is the conducting method among of all radiological methods of diagnostics. Nevertheless a number of restrictions of method reduces its efficiency. The technologies increasing informational content of x-ray mammography – the leading method of screening – due to use of artificial contrasting and advantages of digital technologies are constantly developed. In this review it is described works, in which the authors having clinical experience of application of CESM – contrastenhanced spectral mammography on representative group of women. Positive sides and restrictions of new technology in comparison with mammography, ultrasonography and MRT are shown in this article.

  4. Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    Science.gov (United States)

    Diekmann, Felix; Diekmann, Susanne; Jeunehomme, Fanny; Muller, Serge; Hamm, Bernd; Bick, Ulrich

    2005-07-01

    We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senographe 2000D, GE Healthcare, Buc, France) changed as required. The effect of the protocol parameters on imaging was investigated. Subsequently, 21 patients with 25 suspicious lesions of the breast (10 benign, 1 borderline, and 14 malignant) underwent mammography with administration of an iodine-based contrast medium (Ultravist 370, Schering AG, Berlin, Germany), after approval of ethical committee as well as permission of German federal office for Radiation protection, and informed consent from each patient was obtained. Three sequential digital mammographic images of the respective breast were acquired after administration of the contrast medium at a dose of 1 mL/kg body weight and a flow of 4 mL/s. The postcontrast images were acquired 60, 120, and 180 seconds after administration. Subsequently, the precontrast image was logarithmically subtracted from the postcontrast images. Enhancement of the lesions was measured in absolute terms as well as relative to the enhancement of the glandular tissue. The subtracted images were evaluated for lesion depiction and dynamic contrast enhancement. Lesion-enhancement kinetics were compared with the histologic findings. All malignant lesions were identified on the contrast-enhanced images of digital mammography. Three of the tumors (2 malignant, 1 benign) were detected only by contrast-enhanced mammography and not by standard mammography. Dynamic enhancement curves of benign and malignant tumors in contrast-enhanced mammography look similar to the curves known from gadolinium-enhanced magnetic resonance imaging. Nevertheless differentiation between malignant and benign tumors based on the enhancement patterns cannot be directly taken over from

  5. Temporal subtraction contrast-enhanced dedicated breast CT

    Science.gov (United States)

    Gazi, Peymon M.; Aminololama-Shakeri, Shadi; Yang, Kai; Boone, John M.

    2016-09-01

    The development of a framework of deformable image registration and segmentation for the purpose of temporal subtraction contrast-enhanced breast CT is described. An iterative histogram-based two-means clustering method was used for the segmentation. Dedicated breast CT images were segmented into background (air), adipose, fibroglandular and skin components. Fibroglandular tissue was classified as either normal or contrast-enhanced then divided into tiers for the purpose of categorizing degrees of contrast enhancement. A variant of the Demons deformable registration algorithm, intensity difference adaptive Demons (IDAD), was developed to correct for the large deformation forces that stemmed from contrast enhancement. In this application, the accuracy of the proposed method was evaluated in both mathematically-simulated and physically-acquired phantom images. Clinical usage and accuracy of the temporal subtraction framework was demonstrated using contrast-enhanced breast CT datasets from five patients. Registration performance was quantified using normalized cross correlation (NCC), symmetric uncertainty coefficient, normalized mutual information (NMI), mean square error (MSE) and target registration error (TRE). The proposed method outperformed conventional affine and other Demons variations in contrast enhanced breast CT image registration. In simulation studies, IDAD exhibited improvement in MSE (0-16%), NCC (0-6%), NMI (0-13%) and TRE (0-34%) compared to the conventional Demons approaches, depending on the size and intensity of the enhancing lesion. As lesion size and contrast enhancement levels increased, so did the improvement. The drop in the correlation between the pre- and post-contrast images for the largest enhancement levels in phantom studies is less than 1.2% (150 Hounsfield units). Registration error, measured by TRE, shows only submillimeter mismatches between the concordant anatomical target points in all patient studies. The algorithm was

  6. Enhancement of multispectral thermal infrared images - Decorrelation contrast stretching

    Science.gov (United States)

    Gillespie, Alan R.

    1992-01-01

    Decorrelation contrast stretching is an effective method for displaying information from multispectral thermal infrared (TIR) images. The technique involves transformation of the data to principle components ('decorrelation'), independent contrast 'stretching' of data from the new 'decorrelated' image bands, and retransformation of the stretched data back to the approximate original axes, based on the inverse of the principle component rotation. The enhancement is robust in that colors of the same scene components are similar in enhanced images of similar scenes, or the same scene imaged at different times. Decorrelation contrast stretching is reviewed in the context of other enhancements applied to TIR images.

  7. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images.

    Science.gov (United States)

    Gupta, Suneet; Porwal, Rabins

    2016-01-01

    Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests the most appropriate measures for two of the medical images, namely, brain cancer images and breast cancer images.

  8. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images

    Directory of Open Access Journals (Sweden)

    Suneet Gupta

    2016-01-01

    Full Text Available Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests the most appropriate measures for two of the medical images, namely, brain cancer images and breast cancer images.

  9. Contrast-enhanced ultrasound: clinical applications in patients with atherosclerosis

    NARCIS (Netherlands)

    A.F.L. Schinkel (Arend); M. Kaspar (Mathias); D. Staub (Daniel)

    2016-01-01

    textabstractContrast-enhanced ultrasound (CEUS) is increasingly being used to evaluate patients with known or suspected atherosclerosis. The administration of a microbubble contrast agent in conjunction with ultrasound results in an improved image quality and provides information that cannot be

  10. Dose optimization of contrast-enhanced carotid MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Unterweger, M.; Froehlich, J.M.; Kubik-Huch, R.A.; Seifert, B.; Birrer, M.; Huber, T.; Otto, R. [Institute of Radiology, Cantonal Hospital Baden, Baden (Switzerland)

    2005-09-01

    The purpose of this work was to compare the diagnostic performance of a single-contrast or a double-contrast dose of carotid contrast-enhanced MR angiography (MRA). One-hundred nineteen patients (mean age 65{+-}14.4 years) underwent carotid contrast-enhanced MRA with a standardized protocol (repetition time/echo 3.73 ms/1.38 ms, flip-angle 25 , acquisition-time 19 s, voxel size 1.2 x 1.2 x 0.9 mm{sup 3}) on a 1.5-T scanner (Sonata, Siemens-Medical-Systems) using a neck phased-array coil. Contrast agent was administered intravenously at a rate of 3.0 ml/s, either as a single dose (n=57; 0.1 mmol/kg body weight) or as a double dose (n=62; 0.2 mmol/kg body weight) of meglumine gadoterate (0.5 M/l), followed by 30 ml saline. Qualitative image analysis was performed on maximum intensity projections using a five-point scale. Signal intensities were measured at three different vascular levels on both sides to assess the contrast-to-noise ratios (CNRs). Image quality was rated as good or excellent in all cases. A double dose did not influence the efficacy of carotid enhancement (CNR single dose 69.12{+-}19.8; CNR double dose 70.01{+-}20.7; p=0.81) compared with a single dose. In both dose groups the mean CNRs were inversely related to bodyweight, despite adjusted contrast volumes (p=0.0005). Double-dose contrast-enhanced carotid MRA is not superior to single-dose MRA, as overall diagnostic performance and quantitative contrast enhancement are equal. Being more cost-efficient, a single-dose administration of contrast agent is recommended for MRA of the carotid arteries. (orig.)

  11. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chih-Chung Ting

    2015-07-01

    Full Text Available Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods.

  12. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Science.gov (United States)

    Ting, Chih-Chung; Wu, Bing-Fei; Chung, Meng-Liang; Chiu, Chung-Cheng; Wu, Ya-Ching

    2015-01-01

    Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE) because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA) based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods. PMID:26184219

  13. Quantitative flow phantom for contrast-enhanced breast tomosynthesis

    Science.gov (United States)

    Nock, Melissa L.; Kempston, Michael P.; Mainprize, James G.; Yaffe, Martin J.

    2007-03-01

    The use of contrast agents can help to overcome a lack of intrinsic radiographic contrast between malignant and benign breast tissue by taking advantage of the properties of tumour angiogenesis. Studies of contrast-enhanced mammography have demonstrated increased lesion conspicuity and have shown that this technique provides information on contrast uptake kinetics. It has been suggested that malignant and benign lesions can be differentiated in part by their uptake kinetics, so this additional data may lead to more accurate diagnoses. Tomosynthesis is a 3D x-ray imaging technique that permits lesion depth localization and increased conspicuity in comparison with 2D x-ray projection techniques. This modality, used in combination with contrast agents, promises to be a sensitive method of breast cancer detection. To develop the technique of contrast-enhanced breast tomosynthesis, a dynamic flow phantom has been constructed to provide the same types of imaging challenges anticipated in the clinical setting. These challenges include a low-contrast tumour space, relevant temporal contrast agent uptake and washout profiles, and a need for quantitative analysis of enhancement levels. The design of a flow phantom will be presented that includes a dynamic tumour space, a background that masks the tumour space in images without contrast enhancement, and flow characteristics that simulate tumour contrast agent uptake and washout kinetics. The system is calibrated to relate signal to concentration of the contrast agent using a well plate filled with iodinated water. Iodine detectability in the flow phantom is evaluated in terms of the signal-difference-to-noise ratio for various tomosynthesis image acquisition parameters including number of acquired angular views, angular extent, and reconstruction voxel size.

  14. Dynamic contrast enhanced magnetic resonance imaging in chronic Achilles tendinosis.

    Science.gov (United States)

    Gärdin, Anna; Brismar, Torkel B; Movin, Tomas; Shalabi, Adel

    2013-11-22

    Chronic Achilles tendinosis is a common problem. When evaluating and comparing different therapies there is a need for reliable imaging methods. Our aim was to evaluate if chronic Achilles tendinosis affects the dynamic contrast-enhancement in the tendon and its surroundings and if short-term eccentric calf-muscle training normalizes the dynamic contrast-enhancement. 20 patients with chronic Achilles tendinopathy were included. Median duration of symptoms was 31 months (range 6 to 120 months). Both Achilles tendons were examined with dynamic contrast enhanced MRI before and after a 12- week exercise programme of eccentric calf-muscle training. The dynamic MRI was evaluated in tendon, vessel and in fat ventrally of tendon. Area under the curve (AUC), time to peak of signal, signal increase per second (SI/s) and increase in signal between start and peak as a percentage (SI%) was calculated. Pain and performance were evaluated using a questionnaire. In the fat ventrally of the tendon, dynamic contrast enhancement was significantly higher in the symptomatic leg compared to the contralateral non-symptomatic leg before but not after treatment. Despite decreased pain and improved performance there was no significant change of dynamic contrast enhancement in symptomatic tendons after treatment. In Achilles tendinosis there is an increased contrast enhancement in the fat ventrally of the tendon. The lack of correlation with symptoms and the lack of significant changes in tendon contrast enhancement parameters do however indicate that dynamic enhanced MRI is currently not a useful method to evaluate chronic Achilles tendinosis.

  15. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  16. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  17. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    Science.gov (United States)

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  18. Contrast-enhanced ultrasound for molecular imaging of angiogenesis.

    Science.gov (United States)

    Eisenbrey, J R; Forsberg, F

    2010-08-01

    Molecular imaging of angiogenesis using contrast-enhanced ultrasound allows for functional, real-time, inexpensive imaging of angiogenesis. The addition of stabilized microbubbles as contrast agents greatly improves ultrasound signal to noise ratio/signal strength/image quality (up to 25 dB) and allows for imaging of angiogenic vasculature. In this article recent advances in the usage of contrast-enhanced ultrasound for molecular imaging of angiogenesis are reviewed. The usage of commercially available agents and correlations between their imaging parameters and molecular markers of angiogenesis are reviewed. Recent developments in ultrasound contrast agents targeted to angiogenic markers for both diagnosis and monitoring are discussed. Finally, a brief overview of the emerging field of chemotherapeutic-loaded agents, which can be used with ultrasound-triggered drug delivery, is provided.

  19. BLIND CONTRAST ENHANCEMENT ASSESSMENT BY GRADIENT RATIOING AT VISIBLE EDGES

    Directory of Open Access Journals (Sweden)

    Nicolas Hautière

    2011-05-01

    Full Text Available The contrast of outdoor images acquired under adverse weather conditions, especially foggy weather, is altered by the scattering of daylight by atmospheric particles. As a consequence, differentmethods have been designed to restore the contrast of these images. However, there is a lack of methodology to assess the performances of the methods or to rate them. Unlike image quality assessment or image restoration areas, there is no easy way to have a reference image, which makes the problem not straightforward to solve. In this paper, an approach is proposed which consists in computing the ratio between the gradient of the visible edges between the image before and after contrast restoration. In this way, an indicator of visibility enhancement is provided based on the concept of visibility level, commonly used in lighting engineering. Finally, the methodology is applied to contrast enhancement assessment and to the comparison of tone-mapping operators.

  20. Contrast enhanced ultrasound in the assessment of urogenital pathology

    Directory of Open Access Journals (Sweden)

    Libero Barozzi

    2014-12-01

    Full Text Available Contrast enhanced ultrasound (CEUS is an innovative technique that employs microbubble contrast agents to demonstrate parenchymal perfusion. Although initial clinical application was focused on the liver pathology, a wide variety of clinical conditions can be assessed now with CEUS. CEUS is a well-tolerated technique and is acquiring an increasing role in the assessment of renal pathology because contrast agents are not excreted by the kidney and do not affect the renal function. CEUS demonstrated an accuracy similar to contrast enhanced multi-detector computed tomography (CEMDCT in detecting focal lesions, with the advantage of the real-time assessment of microvascular perfusion by using time-intensity curves. The aim of this paper is to review the main indications of CEUS in the assessment of renal and urogenital pathology. Imaging examples are presented and described. Advantages and limitations of CEUS with reference to conventional US and CE-MDCT are discussed.

  1. Quantitative Nonlinear Contrast-Enhanced Ultrasound of the Breast.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Dave, Jaydev K; Forsberg, Flemming

    2016-08-01

    Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.

  2. Prolapsed cervical disc with diffuse contrast enhancement on CT

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Jun; Shinpo, Tomoyuki; Inoue, Kiyoharu; Shigeno, Taku; Ochiai, Chikayuki

    1985-04-01

    A 48-year-old woman with the C5/6 disc herniation was reported. She had noticed vague pains in the left shoulder a half year earlier. Neurological examination showed left lower cervical radicular pains and incomplete Brown-Sequard syndrome of the same side. The disc herniation was diagnosed by myelography and discography. On the CT examination, surprisingly, the prolapsed disc was homogenously enhanced after the administration of intravenous contrast medium. The vertebral angiography showed increased vascularity behind the C5/6 intervertebral space. At operation, a prolapsed nucleus pulposus with proliferated connective tissue was found and curetted. The etiology of contrast enhancement was discussed.

  3. Microbubble contrast-enhanced ultrasound in liver transplantation.

    Science.gov (United States)

    Berry, Jonathan D; Sidhu, Paul S

    2004-10-01

    The use of liver transplantation for treatment of end-stage liver disease is now commonplace. The accurate assessment of the pre-transplant candidate and long-term follow-up of the posttransplant patient is vital in ensuring that the limited resource of donor livers is appropriately used. Ultrasound is accepted as playing an important role in this process. The advent of microbubble contrast enhanced ultrasound provides new opportunities in terms of improving diagnostic accuracy and obviating more invasive investigations with their associated patient morbidity and mortality. We present the current and developing applications of microbubble contrast-enhanced ultrasound in the field of liver transplantation.

  4. Contrast Enhancement of Mammograms for Rapid Detection of Microcalcification Clusters

    Directory of Open Access Journals (Sweden)

    Hajar Moradmand

    2014-08-01

    Full Text Available Introduction Breast cancer is one of the most common types of cancer among women.  Early detection of breast cancer is the key to reducing the associated mortality rate. The presence of microcalcifications clusters (MCCs is one of the earliest signs of breast cancer. Due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially the presence of MCCs. In order to improve cancer detection, image enhancement methods are often used to aid radiologists. In this paper, a new enhancement method was presented for the accurate and early detection of MCCs in mammograms. Materials and Methods The proposed system consisted of four main steps including: 1 image scaling;2 breast region segmentation;3 noise cancellation using a filter, which is sensitive to MCCs; and 4 contrast enhancement of mammograms using Contrast-Limited Adaptive Histogram Equalization (CLAHE and wavelet transform. To evaluate this method, 120 clinical mammograms were used. Results To evaluate the performance of the image enhancement algorithm, contrast improvement index (CII was used. The proposed enhancement method in this research achieved the highest CII in comparison with other methods applied in this study. The Validity of the results was confirmed by an expert radiologist through visual inspection. Conclusion Detection of MCCs significantly improved in contrast-enhanced mammograms. The proposed method could be helpful for radiologists to easily detect MCCs; it could also decrease the number of biopsies and reduce the frequency of clinical misdiagnosis. Moreover, it could be useful prior to segmentation or classification stages.

  5. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soevik, Aaste; Skogmo, Hege K. (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)), E-mail: aste.sovik@nvh.no; Roedal, Jan (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)); Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway))

    2010-10-15

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  6. Ultrasonido con contraste de masas hepáticas Contrast-enhanced ultrasonography in hepatic masses

    Directory of Open Access Journals (Sweden)

    Hojun Yu

    2009-06-01

    Full Text Available El ultrasonido (US con contraste constituye una poderosa herramienta diagnóstica en la caracterización de masas hepáticas. Las modernas técnicas de ultrasonido con contraste presentan alta sensibilidad con dosis bajas de contraste, lo que juntamente con la técnica de supresión de ecos resulta en imágenes de muy alta resolución temporal y espacial, propiciando el resurgimiento de la ultrasonografía en la era de la tomografía computada (TC y de la resonancia magnética (RM. El agente de contraste utilizado es muy seguro, sin efectos de nefrotoxicidad y apropiado para pacientes con función renal disminuida. La posibilidad de utilizar múltiples inyecciones de micro burbujas y de realizar observaciones reiteradas de patrones de vascularización de las masas hepáticas, la convierten en una herramienta diagnóstica segura y confiable en la resolución de lesiones hepáticas indeterminadas previo a la TC y RM. En este artículo describimos los principios básicos del US con contraste, consideraciones prácticas en la realización de los estudios, debilidades y fortalezas del método en comparación con la TC y RM y patrones de vascularización en las cinco masas hepáticas más comunes: hemangioma, hiperplasia nodular focal, adenoma, carcinoma hepatocelular y metástasis.Contrast-enhanced ultrasonography (CEUS is a powerful tool in the characterization of various liver masses. Modern techniques of contrast ultrasonography are highly sensitive to minute doses of the contrast agent and with the suppression of background tissue echoes result in images with very high contrast resolution. Added to this advantage are the high temporal and spatial resolution intrinsic to sonography in general, which have resulted in a robust resurgence of sonography in this era of CT and MRI. The excellent safety profile of the contrast agent with no nephrotoxicity allows for multiple injections of microbubble in deciphering the vascular structure and enhancement

  7. Contrasting Susceptibilities to Flavescence Dorée in Vitis vinifera, Rootstocks and Wild Vitis Species

    Science.gov (United States)

    Eveillard, Sandrine; Jollard, Camille; Labroussaa, Fabien; Khalil, Dima; Perrin, Mireille; Desqué, Delphine; Salar, Pascal; Razan, Frédérique; Hévin, Cyril; Bordenave, Louis; Foissac, Xavier; Masson, Jean E.; Malembic-Maher, Sylvie

    2016-01-01

    Flavescence dorée (FD) is a quarantine disease of grapevine, involving interactions between the plants, leafhopper vectors, and FD phytoplasma. Characterizing the susceptibility of vine varieties could limit disease propagation. After extensive surveys in vineyards, we showed that Cabernet Sauvignon (CS) is highly susceptible, with a high proportion of symptomatic branches and phytoplasma titers, in contrast to Merlot (M). Localized insect transmissions and grafting showed that phytoplasma circulate in the whole plant in the CS cultivar, but in M they are restricted to the transmission point. Insect-mediated transmission under high confinement mimicking natural conditions confirmed these phenotypes and allowed the classification of 28 Vitis accessions into three distinct categories, according to the percentage of infected plants and their phytoplasma titers. Reduced symptoms, low phytoplasma titers, and low percentages of infected plants were found to be associated in the Vitis vinifera cultivars tested. Interestingly, the low susceptibility of M was observed for one of its parents, i.e., Magdeleine Noire des Charentes. Rootstocks and their Vitis parents, although having high percentages of infected plants and intermediate to high phytoplasma titers, shared a symptomless response. This is troubling, because rootstocks can constitute a silent reservoir of contamination in mother plants or when they grow wild nearby vineyards. Altogether, data suggest distribution of genetic traits within the Vitis genus involved in insect-mediated phytoplasma transmission, multiplication, circulation, and symptom development. PMID:27965681

  8. Contrast enhanced imaging with a stationary digital breast tomosynthesis system

    Science.gov (United States)

    Puett, Connor; Calliste, Jabari; Wu, Gongting; Inscoe, Christina R.; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping

    2017-03-01

    Digital breast tomosynthesis (DBT) captures some depth information and thereby improves the conspicuity of breast lesions, compared to standard mammography. Using contrast during DBT may also help distinguish malignant from benign sites. However, adequate visualization of the low iodine signal requires a subtraction step to remove background signal and increase lesion contrast. Additionally, attention to factors that limit contrast, including scatter, noise, and artifact, are important during the image acquisition and post-acquisition processing steps. Stationary DBT (sDBT) is an emerging technology that offers a higher spatial and temporal resolution than conventional DBT. This phantom-based study explored contrast-enhanced sDBT (CE sDBT) across a range of clinically-appropriate iodine concentrations, lesion sizes, and breast thicknesses. The protocol included an effective scatter correction method and an iterative reconstruction technique that is unique to the sDBT system. The study demonstrated the ability of this CE sDBT system to collect projection images adequate for both temporal subtraction (TS) and dual-energy subtraction (DES). Additionally, the reconstruction approach preserved the improved contrast-to-noise ratio (CNR) achieved in the subtraction step. Finally, scatter correction increased the iodine signal and CNR of iodine-containing regions in projection views and reconstructed image slices during both TS and DES. These findings support the ongoing study of sDBT as a potentially useful tool for contrast-enhanced breast imaging and also highlight the significant effect that scatter has on image quality during DBT.

  9. Efficient contrast enhancement through log-power histogram modification

    NARCIS (Netherlands)

    Wu, T.; Toet, A.

    2014-01-01

    A simple power-logarithm histogram modification operator is proposed to enhance digital image contrast. First a logarithm operator reduces the effect of spikes and transforms the image histogram into a smoothed one that approximates a uniform histogram while retaining the relative size ordering of

  10. Sentinel node detection in melanomas using contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Nielsen, K. Rue; Klyver, H.; Chakera, A. Hougaard

    2009-01-01

    BACKGROUND: Sentinel node (SN) biopsy has proven to be a useful clinical method based on the combination of radionuclide tracer principles and the dye technique. Contrast-enhanced ultrasound (CEUS) has been used successfully for detection of SN in animals, but the use of CEUS has not been reported...

  11. Contrast agent enhanced pQCT of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kallioniemi, A S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Jurvelin, J S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Nieminen, M T [Department of Diagnostic Radiology, POB 50, 90029 OYS, Oulu University Hospital, Oulu (Finland); Lammi, M J [Department of Anatomy, Institute of Biomedicine, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Toeyraes, J [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland)

    2007-02-21

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T{sub 1,Gd} and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  12. Contrast-enhanced endoscopic ultrasonography: advance and current status

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Sung Il [Dept. of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Lee, Dong Ki [Dept. of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review.

  13. Bayesian estimation of cerebral perfusion using reduced-contrast-dose dynamic susceptibility contrast perfusion at 3T.

    Science.gov (United States)

    Nael, K; Mossadeghi, B; Boutelier, T; Kubal, W; Krupinski, E A; Dagher, J; Villablanca, J P

    2015-04-01

    DSC perfusion has been increasingly used in conjunction with other contrast-enhanced MR applications and therefore there is need for contrast-dose reduction when feasible. The purpose of this study was to establish the feasibility of reduced-contrast-dose brain DSC perfusion by using a probabilistic Bayesian method and to compare the results with the commonly used singular value decomposition technique. Half-dose (0.05-mmol/kg) and full-dose (0.1-mmol/kg) DSC perfusion studies were prospectively performed in 20 patients (12 men; 34-70 years of age) by using a 3T MR imaging scanner and a gradient-EPI sequence (TR/TE, 1450/22 ms; flip angle, 90°). All DSC scans were processed with block circulant singular value decomposition and Bayesian probabilistic methods. SNR analysis was performed in both half-dose and full-dose groups. The CBF, CBV, and MTT maps from both full-dose and half-dose scans were evaluated qualitatively and quantitatively in both WM and GM on coregistered perfusion maps. Statistical analysis was performed by using a t test, regression, and Bland-Altman analysis. The SNR was significantly (P < .0001) lower in the half-dose group with 32% and 40% reduction in GM and WM, respectively. In the half-dose group, the image-quality scores were significantly higher in Bayesian-derived CBV (P = .02) and MTT (P = .004) maps in comparison with block circulant singular value decomposition. Quantitative values of CBF, CBV, and MTT in Bayesian-processed data were comparable and without a statistically significant difference between the half-dose and full-dose groups. The block circulant singular value decomposition-derived half-dose perfusion values were significantly different from those of the full-dose group both in GM (CBF, P < .001; CBV, P = .02; MTT, P = .02) and WM (CBF, P < .001; CBV, P = .003; MTT, P = .01). Reduced-contrast-dose (0.05-mmol/kg) DSC perfusion of the brain is feasible at 3T by using the Bayesian probabilistic method with quantitative results

  14. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    National Research Council Canada - National Science Library

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T; Ali, Jalil; Yupapin, Preecha P

    2014-01-01

    .... In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of "adequate contrast enhancement" to overcome sudden jump problem in knee magnetic resonance image...

  15. The Application of Contrast Enhanced Ultrasound in Molecular Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Chung, Jin Haeung; Hwang, Sung Il [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-09-15

    Microbubble contrast agent for ultrasound imaging has come of age, adding entirely new capabilities to real time ultrasound imaging. These new ultrasound imaging techniques exploit the nonlinear echoes that result from the unique interaction between ultrasound and microbubbles, which are readily distinguishable from the echoes of tissues. Contrast enhanced ultrasound can be used to quantify both flow rate and relative vascular volume of the microvasculature in solid lesions or organs, which makes it possible for it to be one of the modalities in molecular imaging. Angiogenesis is one of the important processes contributing to new blood vessel growth that occurs in a variety of physiologic and pathophysiologic states. It is essential for spread and growth of malignant tumors. The advantages of contrast enhanced ultrasound are that it is a noninvasive method for observing tumor angiogenesis. Sonoporation utilizes the interaction of ultrasound with ultrasound contrast agents to temporarily permeabilized the cell membrane allowing for the uptake of DNA, drugs, and other therapeutic compounds from the extracellular environment. Thus, sonoporation is a promising drug delivery and gene therapy technique, limited only by lack of understanding regarding the biophysical mechanism that results in the cell membrane permeability change. In conclusion, ultrasound contrast agent could have a role not only in the molecular imaging field with the advantage of noninvasive quantification of angiogenesis, but also in the field of drug treatment of cells using sonoporation

  16. Pancreatic splenosis demonstrated by contrast-enhanced sonography.

    Science.gov (United States)

    Rogers, Patrick; Williams, M P; Fernando, Rashika; Freeman, Simon

    2011-07-01

    Pancreatic splenosis is a very rare condition whose features on contrast-enhanced ultrasound (CEUS) have not, to our knowledge, been previously reported. We present the imaging findings in a case of pancreatic splenosis, in which a confident diagnosis was achieved with the use of CEUS and confirmed by a labeled heat denatured red cell scan. Accumulation of ultrasound contrast microbubbles in splenic tissue can be readily visualized on late-phase CEUS and this technique has already been used to confirm the nature of intrapancreatic accessory spleens. This case shows that it can also confirm the diagnosis of splenosis. Copyright © 2011 Wiley Periodicals, Inc.

  17. Contrast-enhanced ultrasonography revealed active thoracic bleeding.

    Science.gov (United States)

    Sugihara, Takaaki; Koda, Masahiko; Tokunaga, Shiho; Matono, Tomomitsu; Nagahara, Takakazu; Ueki, Masaru; Murawaki, Yoshikazu; Kaminou, Toshio

    2010-07-01

    A 61-year-old woman with a hepatocellular carcinoma located in the subphrenic region was treated by radiofrequency ablation (RFA) under artificial pleural effusion. During RFA, B-mode ultrasonography showed a swirling high echoic lesion in the artificial pleural effusion. A real-time scan performed using contrast-enhanced ultrasonography (CEUS) revealed a jet-like extravasation of contrast medium and pooling of microbubbles in the pleural cavity, which were confirmed by angiography. CEUS successfully identified the site of bleeding and can be regarded an effective tool for detecting active bleeding in an emergency.

  18. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound

    Directory of Open Access Journals (Sweden)

    John R. Eisenbrey

    2015-01-01

    Full Text Available Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency, subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  19. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  20. Artifacts in contrast-enhanced ultrasound: a pictorial essay.

    Science.gov (United States)

    Fetzer, David T; Rafailidis, Vasileios; Peterson, Cynthia; Grant, Edward G; Sidhu, Paul; Barr, Richard G

    2017-12-02

    Although contrast-enhanced ultrasound (CEUS) has become a widely utilized and accepted modality in much of the world, the associated contrast agents have only recently received approval in the United States. As with all radiological techniques, image artifacts are encountered in CEUS, some of which relate to commonly encountered ultrasound artifacts, while others are unique to this technique. Image artifacts must be recognized when performing and interpreting examinations to improve technique and diagnostic accuracy. In this article, we review artifacts that may be encountered in CEUS, and where possible discuss how to minimize them or mitigate their effect on image quality and interpretation.

  1. Contrast-enhanced Ultrasound for Non-tumor Liver Diseases

    Directory of Open Access Journals (Sweden)

    H Maruyama

    2012-03-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is a simple, safe and reliable technique for the clinical management of patients with various liver diseases. Although the major target of the technique may be focal hepatic lesions, it is also effective for the diagnosis of non-tumor liver diseases, such as grading hepatic fibrosis, characterization of chronic liver diseases and diagnosis of portal vein thrombosis. This review article aimed to overview the recent application of CEUS in the assessment of non-tumor liver diseases. Keywords: Cirrhosis, contrast agent, fibrosis, idiopathic portal hypertension, microbubble, portal vein thrombosis, ultrasound.

  2. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Davide [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)], E-mail: nappaje@yahoo.it; Bodin, Christiane [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Gandolfi, Silvia [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); De Gasperi, Werner [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Borghesi, Andrea; Maroldi, Roberto [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)

    2009-04-15

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  3. The forgotten organ: Contrast enhanced sonography of the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35043 Marburg/Lahn (Germany)], E-mail: goergc@med.uni-marburg.de

    2007-11-15

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration.

  4. A fuzzy approach for contrast enhancement of mammography breast images.

    Science.gov (United States)

    Sahba, Farhang; Venetsanopoulos, Anastasios

    2010-01-01

    This chapter presents a fuzzy-based method for contrast enhancement of mammography images. The selection of appropriate parameters for the required transformations is performed based on image-specific characteristics. The extraction of the breast border is the first step in this method. Images are then transformed to the fuzzy domain using a specific function. Next, an algorithm is applied for intensity adaptation where based on the amount of ambiguity, the proposed technique identifies the suitable form of modifications to enhance the image. Experimental results prove our method to be effective and hence of potential for use in computer-aided diagnosis systems.

  5. Angular compounded OCTA for flow contrast enhancement (Conference Presentation)

    Science.gov (United States)

    Li, Peng; Li, Pei; Cheng, Yuxuan; Zhou, Liping; Ding, Zhihua

    2017-02-01

    Optical coherence tomography angiography (OCTA) is a promising imaging modality that enables a label-free, high-resolution and high-contrast image of biological tissue microvasculature. Typically, the blood flow contrast is implemented by mathematically analyzing the temporal dynamics of light scattering, and setting a threshold to distinguish the dynamic blood flow from the static tissue bed. However, high flow contrast is degraded by the residual overlap that results in misclassification errors between dynamic and static signals. Our study has demonstrated that flow contrast can be enhanced using a single-shot angular compounded OCTA (AC-OCTA). Because a continuous modulation is induced by the offset that the probing beam is away from the beam center in the typical OCT sample arm, different incidence angles in the probing beam are encoded in B-scan modulation frequencies. The complex-valued spectral interferogram is reconstructed by removing the conjugate terms in the depth space and its Fourier transform along the transversal fast-scan direction generates a wide conjugate-free B-scan modulation spectrum in the full space of the spatial domain. By splitting the modulation spectrum, angle-resolved independent sub-angiograms are generated and then compounded to enhance the flow contrast. Both flow phantom and in vivo animal cerebral vascular imaging demonstrated that the proposed angular compounded OCTA can offer a 50% decrease of misclassification errors and an improved flow contrast and vessel connectivity. This AC-OCTA is beneficial to facilitating the interpretation of OCT angiograms in clinical applications.

  6. Vascular applications of contrast-enhanced ultrasound imaging.

    Science.gov (United States)

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf A; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Molecular imaging with dynamic contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A., E-mail: k.a.miles@bsms.ac.u [Clinical Imaging Sciences Centre, Brighton and Sussex Medical School, University of Sussex, Falmer, Brighton (United Kingdom)

    2010-07-15

    Dynamic contrast-enhanced computed tomography (DCE-CT) is a quantitative technique that employs rapid sequences of CT images after bolus administration of intravenous contrast material to measure a range of physiological processes related to the microvasculature of tissues. By combining knowledge of the molecular processes underlying changes in vascular physiology with an understanding of the relationship between vascular physiology and CT contrast enhancement, DCE-CT can be redefined as a molecular imaging technique. Some DCE-CT derived parameters reflect tissue hypoxia and can, therefore, provide information about the cellular microenvironment. DCE-CT can also depict physiological processes, such as vasodilatation, that represent the physiological consequences of molecular responses to tissue hypoxia. To date the main applications have been in stroke and oncology. Unlike some other molecular imaging approaches, DCE-CT benefits from wide availability and ease of application along with the use of contrast materials and software packages that have achieved full regulatory approval. Hence, DCE-CT represents a molecular imaging technique that is applicable in clinical practice today.

  8. Contrast enhanced ultrasound features of hepatic cystadenoma and hepatic cystadenocarcinoma.

    Science.gov (United States)

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Fan, Mei; Ignee, Andre; Serra, Carla; Sparchez, Zeno; Sporea, Ioan; Braden, Barbara; Dietrich, Christoph F

    2017-03-01

    Hepatic (biliary) cystic tumor (HBCT) is a rare focal cystic liver lesion, which has been rarely described in the literature. In our current multicenter, retrospective study, we aimed to analyze contrast enhanced ultrasound (CEUS) features and its diagnostic performance in histologically proved HBCT. Twenty-three patients with single HBCT were retrospectively analyzed. Histologically, 17 (73.9%) were benign hepatic (biliary) cystadenoma (HBCA), 6 (26.1%) were hepatic (biliary) cystadenocarcinoma (HBCAC). All CEUS examinations were assessed by two independent radiologists in consensus. Criteria of CEUS imaging evaluation included the contrast enhancement pattern of lesion (hypoenhancing, hyperenhancing, isoenhancing in comparison to the surrounding liver parenchyma) during the arterial, portal venous and late phases. After injection of ultrasound contrast agents, most of the HBCTs (78.3%, 18/23) had typical honeycomb enhancement pattern of the cystic wall, septa or mural nodules. Comparing between HBCA and HBCAC, hyperenhancement of the honeycomb septa during the arterial phase was more common in HBCA (p = .047). However, hypoenhancement during the portal venous and late phases was the characteristic of HBCAC (p = .041). The EFSUMB algorithm for CEUS for characterization of solid focal liver lesions is also applicable to HBCT. CEUS evaluation can avoid further diagnostic investigations or invasive biopsy procedure.

  9. Gold Nanoparticle-Based Fluorescent Contrast Agent with Enhanced Sensitivity.

    Science.gov (United States)

    Kang, Kyung Aih; Nguyen, Mai-Dung

    2017-01-01

    Gold nanoparticle (GNP) based contrast agents that are highly specific and sensitive for both optical and X-ray/CT imaging modalities are being developed for detecting the cancer expressing nucleolin and matrix metallo-proteinase 14 (MMP-14) on the cell membrane: Nucleolin is normally present in the nucleus. For many cancer cells, however, it is over-expressed on the cell membrane, having it to be a good cancer marker. Aptamer AS1411 is known to be an excellent target for nucleolin and also known to treat several cancer types; and MMP-14 in cancer is involved in tumor angiogenesis, blood vessel re-organization, and metastasis. In the proposed agent, AS1411 is selected as the cancer targeting molecule; and the unique property of GNPs of modulating fluorescence are utilized to allow the agent to trigger its fluorescence upon reacting with MMP-14, at an enhanced fluorescence level. GNPs are also natural X-ray/CT contrast agent. Here, as a part of on-going development of the dual-modality contrast agent, we report that conjugating a safe, NIR fluorophore Cypate at a precisely determined distance from the GNP enhanced the Cypate fluorescence up to two times. In addition, successful conjugation of the nucleolin target AS1411 onto the GNP was confirmed and among the GNPs size range 5-30 nm tested, 10 nm GNPs showed the highest X-ray/CT enhancement.

  10. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT.

    Science.gov (United States)

    Wang, Wei; Chen, Li-Da; Lu, Ming-De; Liu, Guang-Jian; Shen, Shun-Li; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao

    2013-09-01

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. • The confident diagnosis of focal nodular hyperplasia is important in liver imaging. • The centrifugal filling sign is useful for diagnosis of FNHs ≤3 cm. • Contrast-enhanced ultrasound and contrast-enhanced CT have similar diagnostic performance for FNH. • CEUS should be the first-line imaging technique for the diagnosis of FNH.

  11. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  12. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    Science.gov (United States)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-11-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization.

  13. Differentiation of breast cancer from fibroadenoma with dual-echo dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Wang, Shiwei; Delproposto, Zachary; Wang, Haoyu; Ding, Xuewei; Ji, Conghua; Wang, Bei; Xu, Maosheng

    2013-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) of the breast is a routinely used imaging method which is highly sensitive for detecting breast malignancy. Specificity, though, remains suboptimal. Dynamic susceptibility contrast magnetic resonance imaging (DSC MRI), an alternative dynamic contrast imaging technique, evaluates perfusion-related parameters unique from DCE MRI. Previous work has shown that the combination of DSC MRI with DCE MRI can improve diagnostic specificity, though an additional administration of intravenous contrast is required. Dual-echo MRI can measure both T1W DCE MRI and T2*W DSC MRI parameters with a single contrast bolus, but has not been previously implemented in breast imaging. We have developed a dual-echo gradient-echo sequence to perform such simultaneous measurements in the breast, and use it to calculate the semi-quantitative T1W and T2*W related parameters such as peak enhancement ratio, time of maximal enhancement, regional blood flow, and regional blood volume in 20 malignant lesions and 10 benign fibroadenomas in 38 patients. Imaging parameters were compared to surgical or biopsy obtained tissue samples. Receiver operating characteristic (ROC) curves and area under the ROC curves were calculated for each parameter and combination of parameters. The time of maximal enhancement derived from DCE MRI had a 90% sensitivity and 69% specificity for predicting malignancy. When combined with DSC MRI derived regional blood flow and volume parameters, sensitivity remained unchanged at 90% but specificity increased to 80%. In conclusion, we show that dual-echo MRI with a single administration of contrast agent can simultaneously measure both T1W and T2*W related perfusion and kinetic parameters in the breast and the combination of DCE MRI and DSC MRI parameters improves the diagnostic performance of breast MRI to differentiate breast cancer from benign fibroadenomas.

  14. Diffusion-weighted MRI, dynamic susceptibility contrast MRI and ultrasound perfusion quantification of denervated muscle in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Goyault, G.; Beregi, J.P. [University Hospital, Department of Cardiovascular imaging, Cardiologic Hospital, Lille (France); Bierry, G.; Holl, N.; Dietemann, J.L.; Kremer, S. [University Hospital, Department of Neuroradiology, Strasbourg (France); Lhermitte, B. [University Hospital, Department of Pathology, Strasbourg (France)

    2012-01-15

    The purpose of this study was to assess denervated muscle perfusion using dynamic susceptibility contrast MRI (DSCMRI) and contrast-enhanced ultrasound (CEUS), and to measure denervated muscle apparent diffusion coefficient (ADC) on b1000 diffusion-weighted MRI (DWMRI) at 3 T in order to clarify whether muscle denervation leads to an increase in the extracellular extravascular space, or an increase in blood flow - or both. Axotomy of the right sciatic nerve of six white rabbits was performed at day 0. At day 9, hind limb muscles MRI and CEUS were performed to assess the consequences of denervation and both semimembranosus muscles of each rabbit were explanted for histological studies. Signal intensity on T2- and T1-weighted MRI, ADC on DWMRI, maximum signal drop (MSD) on DSCMRI and the area under the curve (AUC) on CEUS were measured over circular regions of interest (ROI), in both semimembranosus muscles. Non-parametric Wilcoxon matched-pairs tests were used to assess the mean differences between denervated and normal muscles. T2 fat-saturated (FS) MRI studies showed a strong signal in the right semimembranosus muscles compared with the left side, and gadolinium enhancement was observed on T1 FS MRI. Denervated muscles show a significant increase in ADC on DWMRI (p < 0.01) and a significant signal enhancement on DSCMR imaging (p < 0.05) and on first-pass CEUS (p < 0.05). The results of this study - based on perfusion- and diffusion-weighted images - suggest that, after denervation, both increased blood flow through muscle tissue and expansion of the extracellular water volume are present. (orig.)

  15. Contrast-enhanced ultrasound for liver imaging: recent advances.

    Science.gov (United States)

    Salvatore, Veronica; Borghi, Alberto; Piscaglia, Fabio

    2012-01-01

    Contrast-enhanced ultrasonography (CEUS), providing relevant informations not available with non-enhanced ultrasonography, greatly impacted the practice of liver imaging. The characterization of focal liver lesions (FLLs), is obtained in a rapid, accurate and safe way and is considered the main hepatic indication; however CEUS offers other established or emergent relevant applications. Metastases detection and assessment of response to locoregional tumor treatment are accepted applications with specific indications. Needle guidance in case of poorly or non visible target lesions at conventional ultrasound is also accepted. The early assessment of response to systemic treatment, and in particular to antiangiogenic ones, by quantification software is an emergent application. The manageability of CEUS determined also its use in the operating theatre, improving the accuracy of intraoperatory US with a significant impact on final surgical strategy. In cirrhotic patients, the role of CEUS was proven highly accurate and sensitive in the characterization of portal vein thrombosis, by identification of contrast arterial enhancement inside the thrombus, that occurs only in case of neoplastic origin. In recent years microbubbles taken up by Kupffer cells, thus possessing a "postvascular" phase, were registered as ultrasound contrast agent in Japan (Sonazoid). During the post-vascular phase tumoral tissue tend to appear as a contrast defect image due to the lack of Kupffer cells, strongly contributing to tumor staging beside characterization. Newly developed techniques, such as fusion imaging or real-time three dimensional US, in addition to other applications of CEUS, in terms of post-transplantation or cholecystitis-related complications, have been recently proposed and will be discussed.

  16. Contrast-enhanced ultrasonographic findings of hepatic paragonimiasis.

    Science.gov (United States)

    Lu, Qiang; Ling, Wen-Wu; Ma, Lin; Huang, Zi-Xing; Lu, Chang-Li; Luo, Yan

    2013-04-07

    To investigate the features of hepatic paragonimiasis on contrast-enhanced ultrasound (CEUS) imaging. Fifteen patients with hepatic paragonimiasis who were admitted to our hospital between March 2008 and August 2012 were enrolled to this study. The conventional ultrasound and CEUS examinations were performed with a Philips IU22 scanner with a 1-5-MHz convex transducer. After conventional ultrasound scanning was completed, the CEUS study was performed. Pulse inversion harmonic imaging was used for CEUS. A bolus injection of 2.4 mL of a sulfur hexafluoride-filled microbubble contrast agent (SonoVue) was administered. CEUS features were retrospectively reviewed and correlated with pathological findings. In total, 16 lesions were detected on CEUS. The mean size of the lesions was 4.4 ± 1.6 cm (range, 1.7-6.6 cm). Subcapsular location was found in 12 lesions (75%). All the lesions were hypoechoic. Six lesions (37.5%) were of mixed content, seven (43.8%) were solid with small cystic areas, and the other three (18.8%) were completely solid. Ten lesions (62.5%) were rim enhanced with irregular tract-like nonenhanced internal areas. Transient wedge-shaped hyperenhancement of the surrounding liver parenchyma was seen in seven lesions (43.8%). Areas with hyper- or iso-enhancement in the arterial phase showed contrast wash-out and appeared hypoenhanced in the late phase. The main pathological findings included: (1) coagulative or liquefactive necrosis within the lesion, infiltration of a large number of eosinophils with the formation of chronic eosinophilic abscesses and sporadic distribution of Charcot-Leyden crystals; and (2) hyperplasia of granulomatous and fibrous tissue around the lesion. Subcapsular location, hypoechogenicity, rim enhancement and tract-like nonenhanced areas could be seen as the main CEUS features of hepatic paragonimiasis.

  17. Contrast-enhanced ultrasonographic findings of hepatic paragonimiasis

    Science.gov (United States)

    Lu, Qiang; Ling, Wen-Wu; Ma, Lin; Huang, Zi-Xing; Lu, Chang-Li; Luo, Yan

    2013-01-01

    AIM: To investigate the features of hepatic paragonimiasis on contrast-enhanced ultrasound (CEUS) imaging. METHODS: Fifteen patients with hepatic paragonimiasis who were admitted to our hospital between March 2008 and August 2012 were enrolled to this study. The conventional ultrasound and CEUS examinations were performed with a Philips IU22 scanner with a 1-5-MHz convex transducer. After conventional ultrasound scanning was completed, the CEUS study was performed. Pulse inversion harmonic imaging was used for CEUS. A bolus injection of 2.4 mL of a sulfur hexafluoride-filled microbubble contrast agent (SonoVue) was administered. CEUS features were retrospectively reviewed and correlated with pathological findings. RESULTS: In total, 16 lesions were detected on CEUS. The mean size of the lesions was 4.4 ± 1.6 cm (range, 1.7-6.6 cm). Subcapsular location was found in 12 lesions (75%). All the lesions were hypoechoic. Six lesions (37.5%) were of mixed content, seven (43.8%) were solid with small cystic areas, and the other three (18.8%) were completely solid. Ten lesions (62.5%) were rim enhanced with irregular tract-like nonenhanced internal areas. Transient wedge-shaped hyperenhancement of the surrounding liver parenchyma was seen in seven lesions (43.8%). Areas with hyper- or iso-enhancement in the arterial phase showed contrast wash-out and appeared hypoenhanced in the late phase. The main pathological findings included: (1) coagulative or liquefactive necrosis within the lesion, infiltration of a large number of eosinophils with the formation of chronic eosinophilic abscesses and sporadic distribution of Charcot-Leyden crystals; and (2) hyperplasia of granulomatous and fibrous tissue around the lesion. CONCLUSION: Subcapsular location, hypoechogenicity, rim enhancement and tract-like nonenhanced areas could be seen as the main CEUS features of hepatic paragonimiasis. PMID:23599629

  18. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging.

    Science.gov (United States)

    Fujii, Shinya; Kido, Aki; Baba, Tsukasa; Fujimoto, Koji; Daido, Sayaka; Matsumura, Noriomi; Konishi, Ikuo; Togashi, Kaori

    2015-04-01

    To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1-46.4%, 85.8-88.5%, 69.2-76.5%, and 84.4-87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p<0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p<0.05) and depth (p<0.01). Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the overestimation by strong focal enhancement of PTE Type 1. PTE Type 2 correlates both with the presence and depth of myometrial invasion and also may play an important role in the diagnosis of LVSI. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Applications of contrast-enhanced ultrasound in the kidney.

    Science.gov (United States)

    Kazmierski, Brittany; Deurdulian, Corinne; Tchelepi, Hisham; Grant, Edward G

    2017-08-30

    Incidental discovery of renal lesions on cross-sectional imaging studies performed for other indications is not uncommon. With the increased reliance on medical imaging, the number of incidentally detected renal lesions has also grown over time. While simple cysts account for the majority of these lesions, the presence of complex features within a cystic lesion, such as septations and solid components, can present a confusing picture. Solid lesions, too, can be indeterminate, and distinguishing between benign solid masses (like lipid-poor angiomyolipomas and oncocytomas) and renal cell carcinoma affects patient management and can prevent unnecessary interventions. Indeterminate renal lesions are traditionally further characterized by multiphase imaging, such as contrast-enhanced computed tomography and magnetic resonance imaging. Contrast-enhanced ultrasound (CEUS) is a new, relatively inexpensive technique that has become increasingly employed in the diagnostic workup of indeterminate renal lesions. With its lack of nephrotoxicity, the absence of ionizing radiation, and the ability to evaluate the enhancement pattern of renal lesions quickly and in real-time, CEUS has unique advantages over traditional imaging modalities. This article provides an overview of the current clinical applications of CEUS in characterizing renal lesions, both cystic and solid. Additional applications of CEUS in the kidney, including its roles in renal transplant evaluation and guidance for percutaneous biopsy, will also be briefly discussed.

  20. Automatic image equalization and contrast enhancement using Gaussian mixture modeling.

    Science.gov (United States)

    Celik, Turgay; Tjahjadi, Tardi

    2012-01-01

    In this paper, we propose an adaptive image equalization algorithm that automatically enhances the contrast in an input image. The algorithm uses the Gaussian mixture model to model the image gray-level distribution, and the intersection points of the Gaussian components in the model are used to partition the dynamic range of the image into input gray-level intervals. The contrast equalized image is generated by transforming the pixels' gray levels in each input interval to the appropriate output gray-level interval according to the dominant Gaussian component and the cumulative distribution function of the input interval. To take account of the hypothesis that homogeneous regions in the image represent homogeneous silences (or set of Gaussian components) in the image histogram, the Gaussian components with small variances are weighted with smaller values than the Gaussian components with larger variances, and the gray-level distribution is also used to weight the components in the mapping of the input interval to the output interval. Experimental results show that the proposed algorithm produces better or comparable enhanced images than several state-of-the-art algorithms. Unlike the other algorithms, the proposed algorithm is free of parameter setting for a given dynamic range of the enhanced image and can be applied to a wide range of image types.

  1. Contrast-Enhanced Ultrasound in Vascular Surgery: Review and Update

    DEFF Research Database (Denmark)

    Bredahl, Kim; Mestre, Xavier Marti; Coll, Ramon Vila

    2017-01-01

    are easy to use, manageable, and safe. This topical review attempts to summarize and highlight the current evidence and future prospects for contrast-enhanced ultrasound in vascular surgery, with a particular focus on opportunities in carotid and lower limb arteriosclerotic disease and surveillance after......Accurate imaging methods associated with minimum patient risk are important tools for clinical decision-making in vascular surgery. Today, traditional imaging methods, such as computed tomography angiography, magnetic resonance angiography, and digital subtraction angiography are the preferred...... modalities. Ultrasound has only challenged these methods in assessment of carotid disease, aortic aneurysms, venous insufficiency, and thromboembolism and in surveillance of in situ bypasses. These practice patterns may change with the introduction of second-generation ultrasound contrast agents which...

  2. Value of contrast-enhanced ultrasound in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Zordo, Tobias de; Mlekusch, Sabine P.; Feuchtner, Gudrun M. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Mur, Erich [Department of Internal Medicine, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Schirmer, Michael [Department of Internal Medicine, Hospital of the Elisabethines Klagenfurt, Voelkermarkter Strasse 15-19, 9020 Klagenfurt (Austria); Klauser, Andrea S. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: andrea.klauser@i-med.ac.at

    2007-11-15

    The purpose of this review is to describe the spectrum of sonographic findings in rheumatic diseases with respect to the diagnostic potential using US contrast media which prove activity or inactivity in synovial tissue where new treatment regimes target. Synovial activity can be found in non-erosive and erosive forms of primary and secondary osteoarthritis, and in inflammatory forms of joint diseases like rheumatoid arthritis and peripheral manifestations of spondyloarthritis including, ankylosing spondylitis, Reiter's syndrome, psoriatic arthritis and enteropathic arthritis. It can also be present in metabolic and endocrine forms of arthritis, in connective tissue arthropathies like systemic lupus erythematosus or scleroderma and in infectious arthritis. Ultrasound should be used as first-line imaging modality in suspected early cases of RA and other forms of arthritis, whereas contrast-enhanced ultrasound (CEUS) can further enable for sensitive assessment of vascularity which correlates with disease activity.

  3. Subendometrial enhancement and peritumoral enhancement for assessing endometrial cancer on dynamic contrast enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, Yonago (Japan); Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Kido, Aki, E-mail: akikido@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Baba, Tsukasa [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Fujimoto, Koji; Daido, Sayaka [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Matsumura, Noriomi; Konishi, Ikuo [Departments of Gynecology and Obstetrics, Graduate School of Medicine, Kyoto University, Kyoto (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto (Japan)

    2015-04-15

    Highlights: •We have assessed the peritumoral enhancement (PTE), which mimics SEE on DCE. •We evaluated the diagnostic accuracy of SEE for the myometrial invasion and the frequency of PTE. •We assessed the relationship between these enhancements and important pathologic factors. •PTE Type 1 is the main factor causing the overestimation of myometrial invasion using SEE on DCE. •PTE Type 2 correlates the myometrial invasion and may play an important role in the diagnosis of LVSI. -- Abstract: Objectives: To evaluate the diagnostic accuracy of subendometrial enhancement (SEE) in assessing the myometrial invasion in endometrial cancer, the frequency and clinical significance of peritumoral enhancement (PTE) on dynamic contrast enhanced (DCE) imaging. Materials and methods: MR images of 147 patients with endometrial cancer were retrospectively analyzed for intact SEE and PTEs: Type 1, a focal early enhancement peritumorally, and Type 2, an irregular thin-layered early intense enhancement peritumorally. Two radiologists independently assessed intact SEE and PTEs on DCE imaging and compared the lesions by the presence and depth of myometrial invasion, grade, lymphovascular space involvement (LVSI), and lymph node metastasis. The relationship between SEE, PTEs, and each factor was analyzed using univariate and multivariate analyses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for SEE. Results: The sensitivity, specificity, PPV, NPV and diagnostic accuracy for myometrial invasion based on SEE disruption on DCE were 96.6%, 32.1–46.4%, 85.8–88.5%, 69.2–76.5%, and 84.4–87.1%. According to multivariate analysis, SEE significantly predicted myometrial invasion (p < 0.0001). PTE Type 2 significantly predicted myometrial invasion presence (p < 0.05) and depth (p < 0.01). Conclusion: Diagnosis of myometrial invasion only by using SEE might be difficult on DCE-MRI due to the

  4. Assessment of mass detection performance in contrast enhanced digital mammography

    Science.gov (United States)

    Carton, Ann-Katherine; de Carvalho, Pablo M.; Li, Zhijin; Dromain, Clarisse; Muller, Serge

    2015-03-01

    We address the detectability of contrast-agent enhancing masses for contrast-agent enhanced spectral mammography (CESM), a dual-energy technique providing functional projection images of breast tissue perfusion and vascularity using simulated CESM images. First, the realism of simulated CESM images from anthropomorphic breast software phantoms generated with a software X-ray imaging platform was validated. Breast texture was characterized by power-law coefficients calculated in data sets of real clinical and simulated images. We also performed a 2-alternative forced choice (2-AFC) psychophysical experiment whereby simulated and real images were presented side-by-side to an experienced radiologist to test if real images could be distinguished from the simulated images. It was found that texture in our simulated CESM images has a fairly realistic appearance. Next, the relative performance of human readers and previously developed mathematical observers was assessed for the detection of iodine-enhancing mass lesions containing different contrast agent concentrations. A four alternative-forced-choice (4 AFC) task was designed; the task for the model and human observer was to detect which one of the four simulated DE recombined images contained an iodineenhancing mass. Our results showed that the NPW and NPWE models largely outperform human performance. After introduction of an internal noise component, both observers approached human performance. The CHO observer performs slightly worse than the average human observer. There is still work to be done in improving model observers as predictors of human-observer performance. Larger trials could also improve our test statistics. We hope that in the future, this framework of software breast phantoms, virtual image acquisition and processing, and mathematical observers can be beneficial to optimize CESM imaging techniques.

  5. Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.

    Science.gov (United States)

    Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Dynamic Contrast-Enhanced CT in Patients with Pancreatic Cancer

    DEFF Research Database (Denmark)

    Eriksen, Rie Ø; Strauch, Louise S; Sandgaard, Michael

    2016-01-01

    The aim of this systematic review is to provide an overview of the use of Dynamic Contrast-enhanced Computed Tomography (DCE-CT) in patients with pancreatic cancer. This study was composed according to the PRISMA guidelines 2009. The literature search was conducted in PubMed, Cochrane Library...... tissue, compared with measurements in pancreatic tissue outside of tumor, or normal pancreatic tissue in control groups of healthy volunteers. The studies were heterogeneous in the number of patients enrolled and scan protocols. Perfusion parameters measured and analyzed by DCE-CT might be useful...

  7. Contrast enhancing solution for use in confocal microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tannous, Zeina; Torres, Abel; Gonzalez, Salvador

    2006-10-31

    A method of optically detecting a tumor during surgery. The method includes imaging at least one test point defined on the tumor using a first optical imaging system to provide a first tumor image. The method further includes excising a first predetermined layer of the tumor for forming an in-vivo defect area. A predetermined contrast enhancing solution is disposed on the in-vivo defect area, which is adapted to interact with at least one cell anomaly, such as basal cell carcinoma, located on the in-vivo defect area for optically enhancing the cell anomaly. Thereafter the defect area can be optically imaged to provide a clear and bright representation of the cell anomaly to aid a surgeon while surgically removing the cell anomaly.

  8. Neuronavigation using susceptibility-weighted venography: application to deep brain stimulation and comparison with gadolinium contrast.

    Science.gov (United States)

    Bériault, Silvain; Sadikot, Abbas F; Alsubaie, Fahd; Drouin, Simon; Collins, D Louis; Pike, G Bruce

    2014-07-01

    Careful trajectory planning on preoperative vascular imaging is an essential step in deep brain stimulation (DBS) to minimize risks of hemorrhagic complications and postoperative neurological deficits. This paper compares 2 MRI methods for visualizing cerebral vasculature and planning DBS probe trajectories: a single data set T1-weighted scan with double-dose gadolinium contrast (T1w-Gd) and a multi-data set protocol consisting of a T1-weighted structural, susceptibility-weighted venography, and time-of-flight angiography (T1w-SWI-TOF). Two neurosurgeons who specialize in neuromodulation surgery planned bilateral STN DBS in 18 patients with Parkinson's disease (36 hemispheres) using each protocol separately. Planned trajectories were then evaluated across all vascular data sets (T1w-Gd, SWI, and TOF) to detect possible intersection with blood vessels along the entire path via an objective vesselness measure. The authors' results show that trajectories planned on T1w-SWI-TOF successfully avoided the cerebral vasculature imaged by conventional T1w-Gd and did not suffer from missing vascular information or imprecise data set registration. Furthermore, with appropriate planning and visualization software, trajectory corridors planned on T1w-SWI-TOF intersected significantly less fine vasculature that was not detected on the T1w-Gd (p < 0.01 within 2 mm and p < 0.001 within 4 mm of the track centerline). The proposed T1w-SWI-TOF protocol comes with minimal effects on the imaging and surgical workflow, improves vessel avoidance, and provides a safe cost-effective alternative to injection of gadolinium contrast.

  9. Optimum wavelet based masking for the contrast enhancement of medical images using enhanced cuckoo search algorithm.

    Science.gov (United States)

    Daniel, Ebenezer; Anitha, J

    2016-04-01

    Unsharp masking techniques are a prominent approach in contrast enhancement. Generalized masking formulation has static scale value selection, which limits the gain of contrast. In this paper, we propose an Optimum Wavelet Based Masking (OWBM) using Enhanced Cuckoo Search Algorithm (ECSA) for the contrast improvement of medical images. The ECSA can automatically adjust the ratio of nest rebuilding, using genetic operators such as adaptive crossover and mutation. First, the proposed contrast enhancement approach is validated quantitatively using Brain Web and MIAS database images. Later, the conventional nest rebuilding of cuckoo search optimization is modified using Adaptive Rebuilding of Worst Nests (ARWN). Experimental results are analyzed using various performance matrices, and our OWBM shows improved results as compared with other reported literature. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Chen, Li-Da; Liu, Guang-Jian; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao [The First Affiliated Hospital of Sun Yat-Sen University Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); Lu, Ming-De [The First Affiliated Hospital of Sun Yat-Sen University Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); The First Affiliated Hospital of Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China); Shen, Shun-Li [The First Affiliated Hospital of Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China)

    2013-09-15

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs {<=}3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs {>=}3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. (orig.)

  11. Contrast-Enhanced Ultrasound Imaging Based on Bubble Region Detection

    Directory of Open Access Journals (Sweden)

    Yurong Huang

    2017-10-01

    Full Text Available The study of ultrasound contrast agent imaging (USCAI based on plane waves has recently attracted increasing attention. A series of USCAI techniques have been developed to improve the imaging quality. Most of the existing methods enhance the contrast-to-tissue ratio (CTR using the time-frequency spectrum differences between the tissue and ultrasound contrast agent (UCA region. In this paper, a new USCAI method based on bubble region detection was proposed, in which the frequency difference as well as the dissimilarity of tissue and UCA in the spatial domain was taken into account. A bubble wavelet based on the Doinikov model was firstly constructed. Bubble wavelet transformation (BWT was then applied to strengthen the UCA region and weaken the tissue region. The bubble region was thereafter detected by using the combination of eigenvalue and eigenspace-based coherence factor (ESBCF. The phantom and rabbit in vivo experiment results suggested that our method was capable of suppressing the background interference and strengthening the information of UCA. For the phantom experiment, the imaging CTR was improved by 10.1 dB compared with plane wave imaging based on delay-and-sum (DAS and by 4.2 dB over imaging based on BWT on average. Furthermore, for the rabbit kidney experiment, the corresponding improvements were 18.0 dB and 3.4 dB, respectively.

  12. Image fusion for dynamic contrast enhanced magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Leach Martin O

    2004-10-01

    Full Text Available Abstract Background Multivariate imaging techniques such as dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI have been shown to provide valuable information for medical diagnosis. Even though these techniques provide new information, integrating and evaluating the much wider range of information is a challenging task for the human observer. This task may be assisted with the use of image fusion algorithms. Methods In this paper, image fusion based on Kernel Principal Component Analysis (KPCA is proposed for the first time. It is demonstrated that a priori knowledge about the data domain can be easily incorporated into the parametrisation of the KPCA, leading to task-oriented visualisations of the multivariate data. The results of the fusion process are compared with those of the well-known and established standard linear Principal Component Analysis (PCA by means of temporal sequences of 3D MRI volumes from six patients who took part in a breast cancer screening study. Results The PCA and KPCA algorithms are able to integrate information from a sequence of MRI volumes into informative gray value or colour images. By incorporating a priori knowledge, the fusion process can be automated and optimised in order to visualise suspicious lesions with high contrast to normal tissue. Conclusion Our machine learning based image fusion approach maps the full signal space of a temporal DCE-MRI sequence to a single meaningful visualisation with good tissue/lesion contrast and thus supports the radiologist during manual image evaluation.

  13. Optimal exposure techniques for iodinated contrast enhanced breast CT

    Science.gov (United States)

    Glick, Stephen J.; Makeev, Andrey

    2016-03-01

    Screening for breast cancer using mammography has been very successful in the effort to reduce breast cancer mortality, and its use has largely resulted in the 30% reduction in breast cancer mortality observed since 1990 [1]. However, diagnostic mammography remains an area of breast imaging that is in great need for improvement. One imaging modality proposed for improving the accuracy of diagnostic workup is iodinated contrast-enhanced breast CT [2]. In this study, a mathematical framework is used to evaluate optimal exposure techniques for contrast-enhanced breast CT. The ideal observer signal-to-noise ratio (i.e., d') figure-of-merit is used to provide a task performance based assessment of optimal acquisition parameters under the assumptions of a linear, shift-invariant imaging system. A parallel-cascade model was used to estimate signal and noise propagation through the detector, and a realistic lesion model with iodine uptake was embedded into a structured breast background. Ideal observer performance was investigated across kVp settings, filter materials, and filter thickness. Results indicated many kVp spectra/filter combinations can improve performance over currently used x-ray spectra.

  14. Influence of contrast-enhanced ultrasound administration setups on microbubble enhancement: a focus on pediatric applications.

    Science.gov (United States)

    Kramer, Michael R; Bhagat, Nishi; Back, Susan J; Poznick, Laura; Forsberg, Flemming; Darge, Kassa; Eisenbrey, John R

    2017-09-11

    In pediatrics, contrast-enhanced ultrasound offers high-quality imaging with an excellent safety profile. To investigate the effects of varying intravenous administration setups on in vitro enhancement and concentration of two commercially available ultrasound contrast agents, taking into consideration potential pediatric applications. We quantified in vitro enhancement using a flow phantom (ATS Laboratories, Bridgeport, CT) and Acuson S3000 ultrasound system (Siemens Healthineers, Mountain View, CA) with a 9L4 probe in Cadence pulse sequencing mode. We determined microbubble concentration with an LSRII flow cytometer (BD Biosciences, San Jose, CA). We investigated Optison (GE Healthcare, Princeton, NJ) and Lumason (Bracco, Geneva, Switzerland) ultrasound contrast agents. The ultrasound (US) contrast agent was injected via a 1 mL syringe and flushed with 5 mL of saline through a 22-gauge diffusion catheter (BD Medical, Franklin Lakes, NJ) with the following variations: in-line injection through a 3-way stopcock with and without a neutral displacement connector (ICU Medical, San Clemente, CA), perpendicular through a 3-way stopcock with and without a connector, and without a 3-way stopcock. We also conducted injections through a 22-gauge standard angiocatheter. Injection through the connector and perpendicular injection via the 3-way stopcock resulted in significant decreases in enhancement for both ultrasound contrast agents (P0.24) nor use of a pediatric diffusion catheter (P>0.28) affected the enhancement. Ultrasound contrast agent enhancement depends on the administration route, although some effects appear to be specific to the ultrasound contrast agent used. To avoid loss of enhancement, neutral displacement connectors and perpendicular injection should be avoided.

  15. Enhanced brain susceptibility to negative stimuli in adolescents: ERP evidences

    Directory of Open Access Journals (Sweden)

    Jiajin eYuan

    2015-04-01

    Full Text Available Background: previous studies investigated neural substrates of emotional face processing in adolescents and its comparison with adults. As emotional faces elicit more of emotional expression recognition rather than direct emotional responding, it remains undetermined how adolescents are different from adults in brain susceptibility to emotionally stressful stimuli. Methods: Event-Related Potentials were recorded for highly negative (HN, moderately negative (MN and Neutral pictures in 20 adolescents and 20 adults while subjects performed a standard/deviant distinction task by pressing different keys, irrespective of the emotionality of deviant stimuli. Results: Adolescents exhibited more negative amplitudes for HN versus neutral pictures in N1 (100-150ms, P2 (130-190ms, N2 (210-290ms and P3 (360-440ms components. In addition, adolescents showed more negative amplitudes for MN compared to neutral pictures in N1, P2 and N2 components. By contrast, adults exhibited significant emotion effects for HN stimuli in N2 and P3 amplitudes but not in N1 and P2 amplitudes, and they did not exhibit a significant emotion effect for MN stimuli at all these components. In the 210-290ms time interval, the emotion effect for HN stimuli was significant across frontal and central regions in adolescents, while this emotion effect was noticeable only in the central region for adults. Conclusions: Adolescents are more emotionally sensitive to negative stimuli compared to adults, regardless of the emotional intensity of the stimuli, possibly due to the immature prefrontal control system over the limbic emotional inputs during adolescence. Keywords: Event-Related Potentials (ERPs; Adolescence; Emotion intensity; Negative pictures; Emotional Susceptibility

  16. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, T.; Adachi, M.; Sugai, Y. [Dept. of Radiology, Yamagata University School of Medicine (Japan); Yamaguchi, K.; Yamaguchi, K. [Dept. of Ophthalmology, Yamagata University School of Medicine (Japan); Kato, T. [3. Dept. of Internal Medicine, Yamagata University School of Medicine (Japan)

    2001-04-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  17. Contrast-enhanced ultrasonography to diagnose complicated acute cholecystitis.

    Science.gov (United States)

    Sagrini, Elisabetta; Pecorelli, Anna; Pettinari, Irene; Cucchetti, Alessandro; Stefanini, Federico; Bolondi, Luigi; Piscaglia, Fabio

    2016-02-01

    Gangrenous cholecystitis and perforation are severe complications of acute cholecystitis, which have a challenging preoperative diagnosis. Early identification allows better surgical management. Contrast-enhanced computed tomography (ceCT) is the current diagnostic gold standard. Contrast-enhanced ultrasonography (CEUS) is a promising tool for the diagnosis of gallbladder perforation, but data from the literature concerning efficacy are sparse. The aim of the study was to evaluate CEUS findings in pathologically proven complicated cholecystitis (gangrenous, perforated gallbladder, pericholecystic abscess). A total of 8 patients submitted to preoperative CEUS, and with subsequent proven acute complicated cholecystitis at surgical inspection and pathological analysis, were retrospectively identified. The final diagnosis was gangrenous/phlegmonous cholecystitis (n. 2), phlegmonous/ulcerative changes plus pericholecystic abscess (n. 2), perforated plus pericholecystic abscess (n. 3), or perforated plus pericholecystic biliary collection (n. 1). Conventional US findings revealed irregularly thickened gallbladder walls in all 8 patients, with vaguely defined walls in 7 patients, four of whom also had striated wall thickening. CEUS revealed irregular enhancing gallbladder walls in all patients. A distinct wall defect was seen in six patients, confirmed as gangrenous/phlegmonous cholecystitis at pathology in all six, and in four as perforation at macroscopic surgical inspection. CEUS is a non-invasive easily repeatable technique that can be performed at the bedside, and is able to accurately diagnose complicated/perforated cholecystitis. Despite the limited sample size in the present case series, CEUS appears as a promising tool for the management of patients with the clinical possibility of having an acute complicated cholecystitis.

  18. Dynamic-contrast-enhanced-MRI with extravasating contrast reagent: Rat cerebral glioma blood volume determination

    Science.gov (United States)

    Li, Xin; Rooney, William D.; Várallyay, Csanád G.; Gahramanov, Seymur; Muldoon, Leslie L.; Goodman, James A.; Tagge, Ian J.; Selzer, Audrey H.; Pike, Martin M.; Neuwelt, Edward A.; Springer, Charles S.

    2010-10-01

    The accurate mapping of the tumor blood volume (TBV) fraction ( vb) is a highly desired imaging biometric goal. It is commonly thought that achieving this is difficult, if not impossible, when small molecule contrast reagents (CRs) are used for the T1-weighted (Dynamic-Contrast-Enhanced) DCE-MRI technique. This is because angiogenic malignant tumor vessels allow facile CR extravasation. Here, a three-site equilibrium water exchange model is applied to DCE-MRI data from the cerebrally-implanted rat brain U87 glioma, a tumor exhibiting rapid CR extravasation. Analyses of segments of the (and the entire) DCE data time-course with this "shutter-speed" pharmacokinetic model, which admits finite water exchange kinetics, allow TBV estimation from the first-pass segment. Pairwise parameter determinances were tested with grid searches of 2D parametric error surfaces. Tumor blood volume ( vb), as well as ve (the extracellular, extravascular space volume fraction), and Ktrans (a CR extravasation rate measure) parametric maps are presented. The role of the Patlak Plot in DCE-MRI is also considered.

  19. Endogenous contrast MRI of cardiac fibrosis: beyond late gadolinium enhancement.

    Science.gov (United States)

    van Oorschot, Joep W M; Gho, Johannes M I H; van Hout, Gerardus P J; Froeling, Martijn; Jansen Of Lorkeers, Sanne J; Hoefer, Imo E; Doevendans, Pieter A; Luijten, Peter R; Chamuleau, Steven A J; Zwanenburg, Jaco J M

    2015-05-01

    The aim of this review is to provide an overview of detection of cardiac fibrosis with MRI using current standards and novel endogenous MRI techniques. Assessment of cardiac fibrosis is important for diagnosis, prediction of prognosis and follow-up after therapy. During the past years, progress has been made in fibrosis detection using MRI. Cardiac infarct size can be assessed noninvasively with late gadolinium enhancement. Several methods for fibrosis detection using endogenous contrast have been developed, such as native T1 -mapping, T1ρ -mapping, Magnetization transfer imaging, and T2 *-mapping. Each of these methods will be described, providing the basic methodology, showing potential applications from applied studies, and discussing the potential and challenges or pitfalls. We will also identify future steps and developments that are needed for bringing these methods to the clinical practice. © 2014 Wiley Periodicals, Inc.

  20. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); O' Gorman, Ruth [University Children' s Hospital Zurich, Center for MR Research, Zurich (Switzerland); Khan, Nadia [University Children' s Hospital Zurich, Moyamoya Center, Division of Neurosurgery, Department of Surgery, Zurich (Switzerland); Kellenberger, Christian J.; Scheer, Ianina [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland)

    2013-05-15

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 {+-} 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement ({kappa} = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation ({rho} = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  1. Value of dynamic susceptibility contrast perfusion MRI in the acute phase of transient global amnesia.

    Directory of Open Access Journals (Sweden)

    Alex Förster

    Full Text Available Transient global amnesia (TGA is a transitory, short-lasting neurological disorder characterized by a sudden onset of antero- and retrograde amnesia. Perfusion abnormalities in TGA have been evaluated mainly by use of positron emission tomography (PET or single-photon emission computed tomography (SPECT. In the present study we explore the value of dynamic susceptibility contrast perfusion-weighted MRI (PWI in TGA in the acute phase.From a MRI report database we identified TGA patients who underwent MRI including PWI in the acute phase and compared these to control subjects. Quantitative perfusion maps (cerebral blood flow (CBF and volume (CBV were generated and analyzed by use of Signal Processing In NMR-Software (SPIN. CBF and CBV values in subcortical brain regions were assessed by use of VOI created in FIRST, a model-based segmentation tool in the Oxford Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB Software Library (FSL.Five TGA patients were included (2 men, 3 women. On PWI, no relevant perfusion alterations were found by visual inspection in TGA patients. Group comparisons for possible differences between TGA patients and control subjects showed significant lower rCBF values bilaterally in the hippocampus, in the left thalamus and globus pallidus as well as bilaterally in the putamen and the left caudate nucleus. Correspondingly, significant lower rCBV values were observed bilaterally in the hippocampus and the putamen as well as in the left caudate nucleus. Group comparisons for possible side differences in rCBF and rCBV values in TGA patients revealed a significant lower rCBV value in the left caudate nucleus.Mere visual inspection of PWI is not sufficient for the assessment of perfusion changes in TGA in the acute phase. Group comparisons with healthy control subjects might be useful to detect subtle perfusion changes on PWI in TGA patients. However, this should be confirmed in larger data sets and serial PWI

  2. Value of dynamic susceptibility contrast perfusion MRI in the acute phase of transient global amnesia.

    Science.gov (United States)

    Förster, Alex; Al-Zghloul, Mansour; Kerl, Hans U; Böhme, Johannes; Mürle, Bettina; Groden, Christoph

    2015-01-01

    Transient global amnesia (TGA) is a transitory, short-lasting neurological disorder characterized by a sudden onset of antero- and retrograde amnesia. Perfusion abnormalities in TGA have been evaluated mainly by use of positron emission tomography (PET) or single-photon emission computed tomography (SPECT). In the present study we explore the value of dynamic susceptibility contrast perfusion-weighted MRI (PWI) in TGA in the acute phase. From a MRI report database we identified TGA patients who underwent MRI including PWI in the acute phase and compared these to control subjects. Quantitative perfusion maps (cerebral blood flow (CBF) and volume (CBV)) were generated and analyzed by use of Signal Processing In NMR-Software (SPIN). CBF and CBV values in subcortical brain regions were assessed by use of VOI created in FIRST, a model-based segmentation tool in the Oxford Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB) Software Library (FSL). Five TGA patients were included (2 men, 3 women). On PWI, no relevant perfusion alterations were found by visual inspection in TGA patients. Group comparisons for possible differences between TGA patients and control subjects showed significant lower rCBF values bilaterally in the hippocampus, in the left thalamus and globus pallidus as well as bilaterally in the putamen and the left caudate nucleus. Correspondingly, significant lower rCBV values were observed bilaterally in the hippocampus and the putamen as well as in the left caudate nucleus. Group comparisons for possible side differences in rCBF and rCBV values in TGA patients revealed a significant lower rCBV value in the left caudate nucleus. Mere visual inspection of PWI is not sufficient for the assessment of perfusion changes in TGA in the acute phase. Group comparisons with healthy control subjects might be useful to detect subtle perfusion changes on PWI in TGA patients. However, this should be confirmed in larger data sets and serial PWI

  3. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    Energy Technology Data Exchange (ETDEWEB)

    Demi, Libertario, E-mail: l.demi@tue.nl; Sloun, Ruud J. G. van; Mischi, Massimo [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Wijkstra, Hessel [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Academic Medical Center, Urology Dept., University of Amsterdam (Netherlands)

    2015-10-28

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  4. Assessment of subclinical atherosclerosis using contrast-enhanced ultrasound.

    Science.gov (United States)

    van den Oord, Stijn C H; ten Kate, Gerrit L; Akkus, Zeynettin; Renaud, Guillaume; Sijbrands, Eric J G; ten Cate, Folkert J; van der Lugt, Aad; Bosch, Johan G; de Jong, Nico; van der Steen, Antonius F W; Schinkel, Arend F L

    2013-01-01

    The sensitivity of standard carotid ultrasound and colour Doppler for the detection of subclinical atherosclerotic plaques is suboptimal. The aim of this study is to assess whether contrast-enhanced ultrasound (CEUS) added to standard carotid ultrasound improves the detection of subclinical atherosclerosis. Carotid intima-media thickness (CIMT) measurement, standard carotid ultrasound including colour Doppler imaging, and CEUS were performed in 100 asymptomatic patients with one or more risk factors for atherosclerosis. CEUS was performed using intravenous administration of SonoVue™ contrast agent (Bracco S.p.A., Milan, Italy). CIMT, standard ultrasound, colour Doppler, and CEUS were reviewed by two independent observers. Standard ultrasound, colour Doppler, and CEUS were scored for the presence of atherosclerotic plaques. Subclinical atherosclerosis was diagnosed if patients had a CIMT above their age-corrected threshold value or if atherosclerotic plaques were present on standard carotid ultrasound clips or CEUS clips. McNemar's test was performed to compare between groups. Twenty-one patients (21%) had a thickened CIMT value and were considered to have subclinical atherosclerosis. Standard carotid ultrasound including colour Doppler demonstrated atherosclerotic plaques in 77 patients (77%). The addition of CEUS to the standard ultrasound protocol demonstrated atherosclerotic plaques in 88 patients (88%). The incorporation of CEUS into the standard carotid ultrasound protocol resulted in a significantly improved detection of patients with subclinical atherosclerosis (P subclinical atherosclerosis in the carotid arteries. Atherosclerotic plaques which were only detected with CEUS and not with standard carotid ultrasound and colour Doppler imaging were predominantly hypoechoic.

  5. Dual-mode registration of dynamic contrast-enhanced ultrasound combining tissue and contrast sequences.

    Science.gov (United States)

    Bouhlel, Nizar; Coron, Alain; Barrois, Guillaume; Lucidarme, Olivier; Bridal, S Lori

    2014-07-01

    This study proposes a new method for automatic, iterative image registration in the context of dynamic contrast-enhanced ultrasound (DCE-US) imaging. By constructing a cost function of image registration using a combination of the tissue and contrast-microbubble responses, this new method, referred to as dual-mode registration, performs alignment based on both tissue and vascular structures. Data from five focal liver lesions (FLLs) were used for the evaluation. Automatic registration based on the dual-mode registration technique and tissue-mode registration obtained using the linear response image sequence alone were compared to manual alignment of the sequence by an expert. Comparison of the maximum distance between the transformations applied by the automatic registration techniques and those from expert manual registration reference showed that the dual-mode registration provided better precision than the tissue-mode registration for all cases. The reduction of maximum distance ranged from 0.25 to 9.3mm. Dual-mode registration is also significantly better than tissue-mode registration for the five sequences with p-values lower than 0.03. The improved sequence alignment is also demonstrated visually by comparison of images from the sequences and the video playbacks of the motion-corrected sequences. This new registration technique better maintains a selected region of interest (ROI) within a fixed position of the image plane throughout the DCE-US sequence. This should reduce motion-related variability of the echo-power estimations and, thus, contribute to more robust perfusion quantification with DCE-US. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. The cerebral intravascular enhancement sign is not specific: a contrast-enhanced MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Bakshi, R.; Kinkel, W.R.; Bates, V.E.; Mechtler, L.L.; Kinkel, P.R. [Lucy Dent Imaging Center, University at Buffalo, NY (United States)

    1999-02-01

    The intravascular enhancement (IVE) sign, also known as the ``arterial enhancement sign``, is an abnormal finding in the brain on contrast-enhanced MRI studies. IVE has been described in arterial cerebrovascular disorders, most commonly in acute or subacute arterial ischemic infarcts. However, the specificity of this sign has not been established. We describe four patients with disorders other than arterial strokes in whom gadolinium-enhanced high-field (1.5 T) MRI suggested IVE. The conditions were herpes simplex viral encephalitis, idiopathic cerebellitis, pneumococcal meningitis, and superior sagittal sinus thrombosis with venous infarction. IVE in these cases may be due to multiple factors, including arterial, venous, perivascular, and leptomeningeal or sulcal contrast medium accumulation. Our observations suggest that arterial ischemia, previously described as the cardinal cause of IVE, probably does not explain all instances, and urge caution in interpreting this sign as a specific MRI manifestation of acute arterial infarction or ischemia. (orig.) With 4 figs., 1 tab., 44 refs.

  7. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Erlend K.F. [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Hole, Knut Hakon; Lund, Kjersti V. [Department of Radiology, Oslo University Hospital, Oslo (Norway); Sundfor, Kolbein [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Kristensen, Gunnar B. [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Institute for Medical Informatics, Oslo University Hospital, Oslo (Norway); Lyng, Heidi [Department of Radiation Biology, Oslo University Hospital, Oslo (Norway); Malinen, Eirik, E-mail: eirik.malinen@fys.uio.no [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Department of Physics, University of Oslo, Oslo (Norway)

    2012-03-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  8. Autoimmune pancreatitis: Assessment of the enhanced duct sign on multiphase contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Yuichi, E-mail: kawai.yuichi@a.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Suzuki, Kojiro, E-mail: kojiro@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Itoh, Shigeki, E-mail: shigeito@nagoya-1st.jrc.or.jp [Department of Diagnostic Radiology, Japan Red Cross Nagoya Daiichi Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya 453-8511 (Japan); Takada, Akira, E-mail: takadaa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Mori, Yoshine, E-mail: yoshine@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Naganawa, Shinji, E-mail: naganawa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)

    2012-11-15

    Purpose: To assess the usefulness of the computed tomography (CT) finding of main pancreatic duct (MPD) wall enhancement, termed the 'enhanced duct sign', for diagnosis of autoimmune pancreatitis (AIP) in comparison with diagnosis of pancreatic carcinoma and chronic pancreatitis. Materials and methods: Two radiologists independently evaluated the presence or absence of the enhanced duct sign on multiphase contrast-enhanced CT in patients with AIP (n = 55), pancreatic carcinoma (n = 50), and chronic pancreatitis (n = 50). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of AIP were calculated. In patients demonstrating the enhanced duct sign, additional findings were evaluated by consensus. Results: The enhanced duct sign was more frequently observed in patients with AIP (37/55, 67%) than in patients with pancreatic carcinoma (5/50, 10%) or chronic pancreatitis (0/50, 0%) (P < 0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the finding were 0.67, 0.95, 0.85, 0.88, and 0.84, respectively. In AIP, the lumen within the enhanced duct was completely or partially invisible in 29 of 37 (78%) patients, and the enhanced duct was observed within the affected pancreatic parenchyma in 35 of 37 (95%) patients. In pancreatic carcinoma, the lumen within the enhanced duct was visible in all patients (5/5, 100%), and the enhanced duct was observed downstream of the tumor (5/5, 100%). Conclusion: The enhanced duct sign is highly specific of AIP.

  9. Systematic review of the safety and efficacy of contrast injection via venous catheters for contrast-enhanced computed tomography

    Directory of Open Access Journals (Sweden)

    S.B. Buijs

    Full Text Available Objective: To examine the safety and efficacy of contrast injection through a central venous catheter (CVC for contrast-enhanced computed tomography (CECT. Methods: A systematic literature search was performed using PubMed. Studies were deemed eligible if they reported on the use of CVCs for contrast administration. Selected articles were assessed for their relevance and risk of bias. Articles with low relevance and high risk of bias or both were excluded. Data from included articles was extracted. Results: Seven studies reported on the use of CVCs for contrast administration. Catheter rupture did not occur in any study. The incidence of dislocation ranged from 2.2-15.4%. Quality of scans was described in three studies, with less contrast enhancement of pulmonary arteries and the thoracic aorta in two studies, and average or above average quality in one study. Four other studies used higher flowrates, but did not report quality of scans. Conclusion: Contrast injection via CVCs can be performed safely for CECT when using a strict protocol. Quality of scans depended on multiple factors like flow rate, indication of the scan, and cardiac output of the patient. In each patient, an individual evaluation whether to use the CVC as access for contrast media should be made, while bolus tracking may be mandatory in most cases. Keywords: Central venous catheter, CVC, Contrast, Contrast-enhanced, CT-scan

  10. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Cebeci, H, E-mail: hcebeci16@gmail.com [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Aydin, O [Department of Radiology, Uludag University Medical School, Bursa (Turkey); Ozturk-Isik, E; Gumus, C [Department of Biomedical Engineering, Yeditepe University, Istanbul (Turkey); Inecikli, F [Department of Radiology, Kanuni Sultan Suleyman Educational and Research Hospital, Istanbul (Turkey); Bekar, A; Kocaeli, H [Department of Neurosurgery, Uludag University Medical School, Bursa (Turkey); Hakyemez, B [Department of Radiology, Uludag University Medical School, Bursa (Turkey)

    2014-10-15

    Highlights: • We compared the perfusion parameters obtained with both DSC and ASL perfusion imaging methods. • In ASL perfusion imaging, we also created quantitative CBF maps. • All patients included in the study had histopathological diagnose. • All MR examinations are done with 3T MR imaging system. - Abstract: Purpose: Arterial spin labeling perfusion imaging (ASL-PI) is a non-invasive perfusion imaging method that can be used for evaluation and quantification of cerebral blood flow (CBF). Aim of our study was to evaluating the efficiency of ASL in histopathological grade estimation of glial tumors and comparing findings with dynamic susceptibility contrast perfusion imaging (DSC-PI) method. Methods: This study involved 33 patients (20 high-grade and 13 low-grade gliomas). Multiphase multislice pulsed ASL MRI sequence and a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence were acquired for all the patients. For each patient, perfusion relative signal intensity (rSI), CBF and relative CBF (rCBF) on ASL-PI and relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values on DSC-PI were determined. The relative signal intensity of each tumor was determined as the maximal SI within the tumor divided by SI within symetric region in the contralateral hemisphere on ASL-PI. rCBV and rCBF were calculated by deconvolution of an arterial input function. Relative values of the lesions were obtained by dividing the values to the normal appearing symmetric region on the contralateral hemisphere. For statistical analysis, Mann–Whitney ranksum test was carried out. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBF-ASL, rSI-ASL, rCBV and rCBF ratios and grade of gliomas. Their cut-off values permitting best discrimination was calculated. The correlation between rCBV, rCBF, rSI-ASL and rCBF-ASL and glioma grade was assessed using

  11. Crossed cerebellar diaschisis in acute isolated thalamic infarction detected by dynamic susceptibility contrast perfusion MRI.

    Directory of Open Access Journals (Sweden)

    Alex Förster

    Full Text Available PURPOSE: Crossed cerebellar diaschisis (CCD is a state of neural depression caused by loss of connections to injured neural structures remote from the cerebellum usually evaluated by positron emission tomography. Recently it has been shown that dynamic susceptibility contrast perfusion weighted MRI (PWI may also be feasible to detect the phenomenon. In this study we aimed to assess the frequency of CCD on PWI in patients with acute thalamic infarction. METHODS: From a MRI report database we identified patients with acute isolated thalamic infarction. Contralateral cerebellar hypoperfusion was identified by inspection of time to peak (TTP maps and evaluated quantitatively on TTP, mean transit time (MTT, cerebral blood flow and volume (CBF, CBV maps. A competing cerebellar pathology or an underlying vascular pathology were excluded. RESULTS: A total of 39 patients was included. Common symptoms were hemiparesis (53.8%, hemihypaesthesia (38.5%, dysarthria (30.8%, aphasia (17.9%, and ataxia (15.4%. In 9 patients (23.1% PWI showed hypoperfusion in the contralateral cerebellar hemisphere. All of these had lesions in the territory of the tuberothalamic, paramedian, or inferolateral arteries. Dysarthria was observed more frequently in patients with CCD (6/9 vs. 6/30; OR 8.00; 95%CI 1.54-41.64, p = 0.01. In patients with CCD, the median ischemic lesion volume on DWI (0.91 cm³, IQR 0.49-1.54 cm³ was larger compared to patients with unremarkable PWI (0.51 cm³, IQR 0.32-0.74, p = 0.05. The most pronounced changes were found in CBF (0.94±0.11 and MTT (1.06±0.13 signal ratios, followed by TTP (1.05±0.02. CONCLUSIONS: Multimodal MRI demonstrates CCD in about 20% of acute isolated thalamic infarction patients. Lesion size seems to be a relevant factor in its pathophysiology.

  12. Contrasting patterns of coral bleaching susceptibility in 2010 suggest an adaptive response to thermal stress

    National Research Council Canada - National Science Library

    Guest, James R; Baird, Andrew H; Maynard, Jeffrey A; Muttaqin, Efin; Edwards, Alasdair J; Campbell, Stuart J; Yewdall, Katie; Affendi, Yang Amri; Chou, Loke Ming

    2012-01-01

    Coral bleaching events vary in severity, however, to date, the hierarchy of susceptibility to bleaching among coral taxa has been consistent over a broad geographic range and among bleaching episodes...

  13. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  14. Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement.

    Science.gov (United States)

    Wu, Qiong; Wang, Yan; Li, Yi; Hu, Bing; He, Zhi-Yan

    2016-08-01

    We aimed to investigate different enhancement patterns of solid thyroid nodules on contrast-enhanced ultrasound (CEUS) and then to evaluate the corresponding diagnostic performance in the differentiation of benign and malignant nodules with and without enhancement. 229 solid thyroid nodules in 196 patients who had undergone both conventional ultrasound and CEUS examinations were classified into enhancement and non-enhancement groups. Besides, different enhancement patterns in the enhancement group were characterised with five indicators including arrival time, mode of entrance, echo intensity, homogeneity, and washout time. Then aforementioned indicators were compared between benign and malignant nodules of different sizes (10 mm), and diagnostic performance of significant enhancement indicators was calculated. As for the enhancement group, there were statistically significant differences of predictive value of non-enhancement were 95.51 and 95.83 %, respectively, with an accuracy of 77.29 %. CEUS is a very promising diagnostic technique that could improve the diagnostic accuracy of identifying benign thyroid lesions to spare a large number of patients an unnecessary invasive procedure.

  15. Enhancing contrast of magnetic resonance imaging in patients with ...

    African Journals Online (AJOL)

    DTPA), a recent magnetic resonance imaging (MRI) contrast agent, in hepatobiliary system of patients with liver cirrhosis. Methods: Liver cirrhosis patients that underwent contrast MRI examination at Renai Hospital, Taipei City, Taiwan were ...

  16. Comparison between breast MRI and contrast-enhanced spectral mammography.

    Science.gov (United States)

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-05-12

    The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.

  17. MR imaging of double-contrast enhanced porcine myocardial infarction. Correlation with microdialysis

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S. [Dept. of Diagnostic Radiology, Univ. Hospital, Uppsala (Sweden); Wikstroem, M. [Dept. of Diagnostic Radiology, Univ. Hospital, Uppsala (Sweden); Ericsson, A. [Dept. of Diagnostic Radiology, Univ. Hospital, Uppsala (Sweden); Wikstroem, G. [Dept. of Internal Medicine, Univ. Hospital, Uppsala (Sweden); Waldenstroem, A. [Dept. of Internal Medicine, Univ. Hospital, Uppsala (Sweden); Oeksendal, A. [Nycomed Imaging AS, Oslo (Norway); Hemmingsson, A. [Dept. of Diagnostic Radiology, Univ. Hospital, Uppsala (Sweden)

    1995-07-01

    MR imaging was performed to investigate whether Gd-DTPA-BMA-induced contrast enhancement of myocardial infarction is counteracted by Dy-DTPA-BMA. Myocardial infarction was induced in 5 pigs. Microdialysate probes were inserted in ischemic and nonischemic myocardium. Gd-DTPA-BMA (0.3 mmol/kg b.w.) and Dy-DTPA-BMA (1.0 mmol/kg b.w.) were administered i.v. 4 hours post occlusion. The microdialysate was collected every 10 min and measured for Gd and Dy using inductively coupled plasma atomic emission spectrometry. The pigs were sacrificed 2 hours after administration of contrast media. The concentration of both contrast agents was 3 times higher in infarcted myocardium than in nonischemic myocardium. The infarctions displayed high signal intensity in spin-echo sequences ex vivo. This lack of detectable susceptibility effects from Dy may be caused by loss of cell membrane integrity in infarcted tissue as shown by our microdialysate and biopsy data. (orig.).

  18. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    OpenAIRE

    Prionas, Nicolas D.; Aminololama-Shakeri, Shadi; Yang, Kai; Martinez, Steve R.; Lindfors, Karen K.; Boone, John M.

    2015-01-01

    Dedicated breast computed tomography (bCT) generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obta...

  19. CONTRAST

    DEFF Research Database (Denmark)

    Kristensen, Thomas Krogsgaard

    2007-01-01

    Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon.......Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon....

  20. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles.

    NARCIS (Netherlands)

    Gilad, A.A.; Laarhoven, H.W.M. van; McMahon, M.T.; Walczak, P.; Heerschap, A.; Neeman, M.; Zijl, P.C. van; Bulte, J.W.

    2009-01-01

    A major challenge for cellular and molecular MRI is to study interactions between two different cell populations or biological processes. We studied the possibility to simultaneously image contrast agents based on two different MRI contrast mechanisms: chemical exchange saturation transfer (CEST)

  1. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles

    NARCIS (Netherlands)

    Gilad, Assaf A.; van Laarhoven, Hanneke W. M.; McMahon, Michael T.; Walczak, Piotr; Heerschap, Arend; Neeman, Michal; van Zijl, Peter C. M.; Bulte, Jeff W. M.

    2009-01-01

    A major challenge for cellular and molecular MRI is to study interactions between two different cell populations or biological processes. We studied the possibility to simultaneously image contrast agents based on two different MRI contrast mechanisms: chemical exchange saturation transfer (CEST)

  2. Post-radiotherapy contrast enhancement changes in fast dynamic MRI of cervical carcinoma.

    NARCIS (Netherlands)

    Boss, E.A.; Massuger, L.F.A.G.; Pop, L.A.M.; Verhoef, C.G.; Huisman, H.J.; Boonstra, H.; Barentsz, J.O.

    2001-01-01

    This pilot study determines fast dynamic gadolinium enhanced MRI contrast enhancement parameters (onset of enhancement and time to peak enhancement) before and after radiotherapy in 10 cervical carcinoma patients. Before radiotherapy, onset of enhancement and time to peak enhancement were early,

  3. Negative mood state enhances the susceptibility to unpleasant events: neural correlates from a music-primed emotion classification task.

    Science.gov (United States)

    Yuan, Jiajin; Chen, Jie; Yang, Jiemin; Ju, Enxia; Norman, Greg J; Ding, Nanxiang

    2014-01-01

    Various affective disorders are linked with enhanced processing of unpleasant stimuli. However, this link is likely a result of the dominant negative mood derived from the disorder, rather than a result of the disorder itself. Additionally, little is currently known about the influence of mood on the susceptibility to emotional events in healthy populations. Event-Related Potentials (ERP) were recorded for pleasant, neutral and unpleasant pictures while subjects performed an emotional/neutral picture classification task during positive, neutral, or negative mood induced by instrumental Chinese music. Late Positive Potential (LPP) amplitudes were positively related to the affective arousal of pictures. The emotional responding to unpleasant pictures, indicated by the unpleasant-neutral differences in LPPs, was enhanced during negative compared to neutral and positive moods in the entire LPP time window (600-1000 ms). The magnitude of this enhancement was larger with increasing self-reported negative mood. In contrast, this responding was reduced during positive compared to neutral mood in the 800-1000 ms interval. Additionally, LPP reactions to pleasant stimuli were similar across positive, neutral and negative moods except those in the 800-900 ms interval. Negative mood intensifies the humans' susceptibility to unpleasant events in healthy individuals. In contrast, music-induced happy mood is effective in reducing the susceptibility to these events. Practical implications of these findings were discussed.

  4. Negative mood state enhances the susceptibility to unpleasant events: neural correlates from a music-primed emotion classification task.

    Directory of Open Access Journals (Sweden)

    Jiajin Yuan

    Full Text Available BACKGROUND: Various affective disorders are linked with enhanced processing of unpleasant stimuli. However, this link is likely a result of the dominant negative mood derived from the disorder, rather than a result of the disorder itself. Additionally, little is currently known about the influence of mood on the susceptibility to emotional events in healthy populations. METHOD: Event-Related Potentials (ERP were recorded for pleasant, neutral and unpleasant pictures while subjects performed an emotional/neutral picture classification task during positive, neutral, or negative mood induced by instrumental Chinese music. RESULTS: Late Positive Potential (LPP amplitudes were positively related to the affective arousal of pictures. The emotional responding to unpleasant pictures, indicated by the unpleasant-neutral differences in LPPs, was enhanced during negative compared to neutral and positive moods in the entire LPP time window (600-1000 ms. The magnitude of this enhancement was larger with increasing self-reported negative mood. In contrast, this responding was reduced during positive compared to neutral mood in the 800-1000 ms interval. Additionally, LPP reactions to pleasant stimuli were similar across positive, neutral and negative moods except those in the 800-900 ms interval. IMPLICATIONS: Negative mood intensifies the humans' susceptibility to unpleasant events in healthy individuals. In contrast, music-induced happy mood is effective in reducing the susceptibility to these events. Practical implications of these findings were discussed.

  5. Negative Mood State Enhances the Susceptibility to Unpleasant Events: Neural Correlates from a Music-Primed Emotion Classification Task

    Science.gov (United States)

    Yuan, Jiajin; Chen, Jie; Yang, Jiemin; Ju, Enxia; Norman, Greg J.; Ding, Nanxiang

    2014-01-01

    Background Various affective disorders are linked with enhanced processing of unpleasant stimuli. However, this link is likely a result of the dominant negative mood derived from the disorder, rather than a result of the disorder itself. Additionally, little is currently known about the influence of mood on the susceptibility to emotional events in healthy populations. Method Event-Related Potentials (ERP) were recorded for pleasant, neutral and unpleasant pictures while subjects performed an emotional/neutral picture classification task during positive, neutral, or negative mood induced by instrumental Chinese music. Results Late Positive Potential (LPP) amplitudes were positively related to the affective arousal of pictures. The emotional responding to unpleasant pictures, indicated by the unpleasant-neutral differences in LPPs, was enhanced during negative compared to neutral and positive moods in the entire LPP time window (600–1000 ms). The magnitude of this enhancement was larger with increasing self-reported negative mood. In contrast, this responding was reduced during positive compared to neutral mood in the 800–1000 ms interval. Additionally, LPP reactions to pleasant stimuli were similar across positive, neutral and negative moods except those in the 800–900 ms interval. Implications Negative mood intensifies the humans' susceptibility to unpleasant events in healthy individuals. In contrast, music-induced happy mood is effective in reducing the susceptibility to these events. Practical implications of these findings were discussed. PMID:24587070

  6. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Wiener, Edzard [Department of Radiology, Technical University Munich, Ismaninger Str. 22, D-81675 Munich (Germany)]. E-mail: ewiener@roe.med.tu-muenchen.de; Woertler, Klaus [Department of Radiology, Technical University Munich, Ismaninger Str. 22, D-81675 Munich (Germany); Weirich, Gregor [Institute of Pathology, Technical University Munich, Troger Str. 18, D-81675 Munich (Germany); Rummeny, Ernst J. [Department of Radiology, Technical University Munich, Ismaninger Str. 22, D-81675 Munich (Germany); Settles, Marcus [Department of Radiology, Technical University Munich, Ismaninger Str. 22, D-81675 Munich (Germany)

    2007-07-15

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T {sub 1} and T {sub 2} were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T {sub 1}, T {sub 2} and {delta}R {sub 1}, {delta}R {sub 2} profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute {delta}R {sub 2}-effect in cartilage is at least as large as the {delta}R {sub 1}-effect for all contrast agents. Maximum changes were 5-12 s{sup -1} for {delta}R {sub 1} and 8-15 s{sup -1} for {delta}R {sub 2}. This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, {delta}R {sub 2} can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than {delta}R {sub 1}.

  7. Evaluation of hepatic contrast enhancement with a hepatocyte-specific magnetic resonance imaging contrast agent (gadoxetic acid) in healthy dogs.

    Science.gov (United States)

    Bratton, Alexandra K; Nykamp, Stephanie G; Gibson, Thomas W G; Cruz-Arámbulo, Robert; Kruth, Stephen A

    2015-03-01

    To determine, by means of MRI, the time to maximal contrast enhancement in T1-weighted images following IV administration of gadoxetic acid in healthy dogs and assess the impact of gadoxetic acid on the signal intensity of T2-weighted images. 7 healthy dogs. No hepatic abnormalities were detected during ultrasonographic examination. Each dog was anesthetized and positioned in dorsal recumbency for MRI. Transverse T1- and T2-weighted images of the liver were acquired prior to and following (at 5-minute intervals) IV injection of 0.1 mL of gadoxetic acid/kg. Signal intensity of the liver parenchyma was measured in 3 regions of interest in the T1- and T2-weighted images before and at various times point after contrast agent administration. Time versus signal-to-noise ratio curves were plotted to determine time to maximal contrast enhancement and contrast agent-related changes in signal intensity in T2-weighted images. Analysis of T1-weighted images revealed that mean ± SD time to maximal enhancement after gadoxetic acid injection was 10.5 ± 3.99 minutes. Signal intensity of T2-weighted images was not significantly affected by gadoxetic acid administration. No injection-related adverse effects were observed in any dog. Results indicated that gadoxetic acid can be used for hepatic MRI in healthy dogs and the resultant hepatic enhancement patterns are similar to those described for humans. Maximal contrast enhancement occurred between 10 and 15 minutes after contrast agent injection; thus, T2-weighted images may be obtained in the interval between injection and maximal enhancement for a more time-efficient clinical protocol.

  8. Non-mass-like enhancement on contrast-enhanced breast MR imaging: lesion characterization using combination of dynamic contrast-enhanced and diffusion-weighted MR images.

    Science.gov (United States)

    Yabuuchi, Hidetake; Matsuo, Yoshio; Kamitani, Takeshi; Setoguchi, Taro; Okafuji, Takashi; Soeda, Hiroyasu; Sakai, Shuji; Hatakenaka, Masamitsu; Kubo, Makoto; Tokunaga, Eriko; Yamamoto, Hidetaka; Honda, Hiroshi

    2010-07-01

    To evaluate the diagnostic accuracy of a combination of dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted MR imaging (DWI) in characterization of lesions showing non-mass-like enhancement on breast MR imaging and to find the strongest discriminators between carcinoma and benignancy. We analyzed consecutive MR images in 45 lesions showing non-mass like enhancement in 41 patients. We analyzed lesion size, distribution, internal enhancement, kinetic curve pattern, and apparent diffusion coefficient (ADC) values. We applied univariate and multivariate analyses to find the strongest indicators for malignancy. In a validation study, 22 non-mass-like enhancement lesions in 21 patients were examined. We calculated diagnostic accuracy when we presume category 4b, 4c, and 5 lesions as malignant or high to moderate suspicion for malignancy, and category 4a and 3 as low suspicion for malignancy or benign. Segmental distribution (P=0.018), clumped internal enhancement (P=0.005), and ADC less than 1.3 x 10(-3) mm(2)/s (P=0.047) were the strongest MR indicators of malignancy. In a validation study, sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87% (13/15), 86% (6/7), 93% (13/14), 75% (6/8) and 86% (19/22), respectively. The combination of DCE-MRI and DWI showed high diagnostic accuracy in characterization of non-mass-like enhancement lesions on breast MR images. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  9. Effect of Mahanarva fimbriolata (Hemiptera: Cercopidae) Attack on Photosynthetic Parameters of Sugarcane Genotypes of Contrasting Susceptibility.

    Science.gov (United States)

    Soares, Bruno Oliveira; Chaves, Vinicius de Vicente; Tomaz, Adriano Cirino; Kuki, Kacilda Naomi; Peternelli, Luiz Alexandre; Barbosa, Márcio Henrique Pereira

    2017-12-05

    The aim of this study was to compare the effect of spittlebug Mahanarva fimbriolata Stål (Hemiptera: Cercopidae) on photosynthetic parameters of both a susceptible (SP81-3250) and a resistant (H.Kawandang) sugarcane genotype. In the first assay, the susceptibility level of genotypes to spittlebug was confirmed by comparing damage score and chlorophyll content of the plants. In the second assay, the effect of spittlebug nymphs on photosynthetic characteristics was assessed using the following parameters: Net photosynthetic rate (A), carboxylation efficiency (A/Ci), stomata conductance (gS), transpiration (E), electron transport rate (ETR), maximum quantum yield of Photosystem 2 (PSII) (FV/FM), effective quantum yield (Y(II)), photochemical quenching (Y(NPQ)), and nonphotochemical quenching (Y(NO)). Spittlebug nymphs affected the photosynthetic process of the susceptible genotype SP81-3250 by decreasing the Chl content, ETR, FV/FM, and Y(II). However, this genotype was able to maintain A probably due to its ability to maintain stomata aperture, increase the carboxylation efficiency of Rubisco, and dissipate excess energy through the xanthophyll cycle, as Y(NPQ) increased under the spittlebug attack. On the other hand, the spittlebug did not affect Chl content and FV/FM of the H.Kawandang genotype. Furthermore, H.Kawandang increased A to compensate for the sink demand by the spittlebug by increasing stomatal aperture and carboxylation efficiency and increasing efficiency of the photochemical apparatus in converting light energy into chemical products. We can conclude that the feeding habits of spittlebug nymphs have different impacts on photosynthesis of susceptible and resistant sugarcane genotypes. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  11. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Bin [Chung-Ang University Hospital, Chung-Ang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Moon, Min Hoan; Sung, Chang Kyu [Seoul National University College of Medicine, 41, Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Oh, Sohee [Seoul National University College of Medicine, 41, Department of Biostatistics, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Lee, Young Ho [Kwandong University College of Medicine, Department of Radiology, Cheil General Hospital and Women' s Healthcare Center, Seoul (Korea, Republic of)

    2014-11-15

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  12. Clinical Applications of Contrast-Enhanced Perfusion MRI Techniques in Gliomas: Recent Advances and Current Challenges.

    Science.gov (United States)

    Zhang, Junfeng; Liu, Heng; Tong, Haipeng; Wang, Sumei; Yang, Yizeng; Liu, Gang; Zhang, Weiguo

    2017-01-01

    Gliomas possess complex and heterogeneous vasculatures with abnormal hemodynamics. Despite considerable advances in diagnostic and therapeutic techniques for improving tumor management and patient care in recent years, the prognosis of malignant gliomas remains dismal. Perfusion-weighted magnetic resonance imaging techniques that could noninvasively provide superior information on vascular functionality have attracted much attention for evaluating brain tumors. However, nonconsensus imaging protocols and postprocessing analysis among different institutions impede their integration into standard-of-care imaging in clinic. And there have been very few studies providing a comprehensive evidence-based and systematic summary. This review first outlines the status of glioma theranostics and tumor-associated vascular pathology and then presents an overview of the principles of dynamic contrast-enhanced MRI (DCE-MRI) and dynamic susceptibility contrast-MRI (DSC-MRI), with emphasis on their recent clinical applications in gliomas including tumor grading, identification of molecular characteristics, differentiation of glioma from other brain tumors, treatment response assessment, and predicting prognosis. Current challenges and future perspectives are also highlighted.

  13. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI.

    Science.gov (United States)

    Iliff, Jeffrey J; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-03-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes to amyloid plaque deposition and Alzheimer's disease progression. Here we provide proof of concept that glymphatic pathway function can be measured using a clinically relevant imaging technique. Dynamic contrast-enhanced MRI was used to visualize CSF-ISF exchange across the rat brain following intrathecal paramagnetic contrast agent administration. Key features of glymphatic pathway function were confirmed, including visualization of para-arterial CSF influx and molecular size-dependent CSF-ISF exchange. Whole-brain imaging allowed the identification of two key influx nodes at the pituitary and pineal gland recesses, while dynamic MRI permitted the definition of simple kinetic parameters to characterize glymphatic CSF-ISF exchange and solute clearance from the brain. We propose that this MRI approach may provide the basis for a wholly new strategy to evaluate Alzheimer's disease susceptibility and progression in the live human brain.

  14. Use of contrast-enhanced ultrasonography to characterize adrenal gland tumors in dogs.

    Science.gov (United States)

    Pey, Pascaline; Rossi, Federica; Vignoli, Massimo; Duchateau, Luc; Marescaux, Laurent; Saunders, Jimmy H

    2014-10-01

    To describe the contrast-enhanced ultrasonographic characteristics and vascular patterns of adrenal gland tumors in dogs and determine whether those features are indicative of malignancy or histologic type of tumor. 14 dogs with 16 adrenal gland lesions (10 carcinomas [8 dogs], 3 adenomas [3 dogs], and 3 pheochromocytomas [3 dogs]). Unsedated dogs with adrenal gland lesions underwent B-mode ultrasonography and contrast-enhanced ultrasonography ≤ 48 hours before adrenalectomy; contrast-enhanced ultrasonographic examinations were video-recorded. Macroscopic evaluation of the adrenal gland lesions and histologic examination of removed adrenal gland tissues were subsequently performed. Surgical and histopathologic findings and the ultrasonographic and contrast-enhanced ultrasonographic characteristics were recorded for the various tumor types. Time-intensity curves were generated from the contrast-enhanced ultrasonographic recordings and used to calculate regional blood volume (value proportional to area under the curve) and mean transit time (time the lesion began to enhance to the half-peak intensity). In adrenal gland carcinomas, tortuous feeding vessels were noticeable during the arterial and venous phases of contrast enhancement. Heterogeneity of contrast enhancement was evident only in malignant tumors. Compared with adenomas, adrenal gland carcinomas and pheochromocytomas had significantly less regional blood volume. Mean transit times were significantly shorter in adrenal gland carcinomas and pheochromocytomas than in adenomas. For dogs, evaluation of the vascular pattern and contrast-enhancement characteristics of adrenal gland tumors by means of contrast-enhanced ultrasonography may be useful in assessment of malignancy and tumor type.

  15. Transmission grating stretcher for contrast enhancement of high power lasers.

    Science.gov (United States)

    Tang, Yunxin; Hooker, Chris; Chekhlov, Oleg; Hawkes, Steve; Collier, John; Rajeev, P P

    2014-12-01

    We propose, for the first time, a transmission grating stretcher for high power lasers and demonstrate its superiority over conventional, reflective gold grating stretchers in terms of pulse temporal quality. We show that, compared to a conventional stretcher with the same stretching factor, the transmission-grating based stretcher yields more than an order of magnitude improvement in the contrast pedestal. We have also quantitatively characterized the roughness of the grating surfaces and estimated its impact on the contrast pedestal.

  16. Effect of magnetic susceptibility contrast medium on myocardial signal intensity with fast gradient-recalled echo and spin-echo MR imaging: initial experience in humans.

    Science.gov (United States)

    Sakuma, H; O'Sullivan, M; Lucas, J; Wendland, M F; Saeed, M; Dulce, M C; Watson, A; Bleyl, K L; LaFrance, N D; Higgins, C B

    1994-01-01

    To show the effect of dysprosium diethylenetriaminepentaacetic acid bis-methylamine injection on the images of normal human myocardium. T2-sensitive fast gradient-recalled echo (GRE) (repetition time [TR], 10.8 msec; echo time [TE], 4.2 msec) and spin-echo (SE) (TR, three RR intervals; TE, 60 msec) magnetic resonance (MR) imaging with driven equilibrium-preparation pulse was used to produce T2 contrast material enhancement. The contrast agent was injected into 12 healthy subjects at doses of 0.05, 0.1, 0.2, 0.4, and 0.6 mmol/kg. Driven equilibrium-prepared GRE images showed a transient decrease of myocardial signal intensity at doses of 0.2-0.6 mmol/kg. Postcontrast T2-weighted SE images showed a myocardial signal attenuation (30%-45% decrease) at a dose of 0.4 mmol/kg or higher. Dynamic MR imaging with a magnetic susceptibility contrast medium can be used to monitor the first pass of contrast media through human myocardium with a conventional MR imager and a fast GRE sequence.

  17. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Yuko [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kawamoto, Hirofumi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan)]. E-mail: h-kawamo@md.okayama-u.ac.jp; Takaki, Akinobu [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Ishida, Etsuji [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Ogawa, Tsuneyoshi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kuwaki, Kenji [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kobayashi, Yoshiyuki [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Sakaguchi, Kohsaku [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Shiratori, Yasushi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan)

    2007-01-15

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase ({kappa} coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors.

  18. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yuexiang, E-mail: wangyuexiang1999@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Cheng Zhigang, E-mail: qlczg@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Li Junlai, E-mail: junlai555@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Tang Jie, E-mail: txiner@vip.sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2010-06-15

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  19. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

    Science.gov (United States)

    Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-11-01

    To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound

  20. Staging accuracy of pancreatic cancer: Comparison between non-contrast-enhanced and contrast-enhanced PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tomohiro [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Tateishi, Ukihide, E-mail: utateish@yokohama-cu.ac.jp [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Endo, Itaru [Department of Surgery, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Inoue, Tomio [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan)

    2014-10-15

    Purpose: Our aim was to clarify the diagnostic impact of contrast-enhanced (CE) {sup 18}F-fluorodeoxyglucose (FDG)–positron emission tomography (PET)/computed tomography (CT) for staging of pancreatic cancer compared to non-CE PET/CT. Method and materials: Between April 2006 and November 2009, a total of 95 patients (age range, 36–83 years [mean age, 67]) with primary pancreatic cancer underwent {sup 18}F-FDG PET/CT examinations. Diagnostic accuracy was compared between non-CE PET/CT and CE PET/CT. Images were analyzed visually and quantitatively by two blinded reviewers. Reference standard was histological examination in 48 patients (51%) and/or confirmation of an obvious progression in number and/or size of the lesions on follow-up CT examinations in 47 patients (49%). Results: For T-staging, invasion of duodenum (n = 20, 21%), mesentery (n = 12, 13%), and retroperitoneum (n = 13, 14%) was correctly diagnosed by both modalities. The ROC analyses revealed that the Az values of celiac artery (CA), common hepatic artery (CHA), splenic artery (SV), and superior mesenteric vein (SMV) invasion were significantly higher in the CE PET/CT group for both readers. Nodal metastasis was correctly diagnosed by CE PET/CT in 38 patients (88%) and by non-CE PET/CT in 45 patients (87%). Diagnostic accuracies of nodal metastasis in two modalities were similar. Using CE PET/CT, distant metastasis, scalene node metastasis, and peritoneal dissemination were correctly assigned in 39 patients (91%), while interpretation based on non-CE PET/CT revealed distant metastasis, scalene node metastasis, and peritoneal dissemination in 42 patients (81%). Diagnostic accuracy of distant metastasis, scalene node metastasis, and peritoneal dissemination with CE PET/CT was significantly higher than that of non-CE PET/CT (p < 0.05). Conclusion: CE PET/CT allows a more precise assessment of distant metastasis, scalene node metastasis, and peritoneal dissemination in patients with pancreatic cancer.

  1. Image contrast enhancement using adjacent-blocks-based modification for local histogram equalization

    Science.gov (United States)

    Wang, Yang; Pan, Zhibin

    2017-11-01

    Infrared images usually have some non-ideal characteristics such as weak target-to-background contrast and strong noise. Because of these characteristics, it is necessary to apply the contrast enhancement algorithm to improve the visual quality of infrared images. Histogram equalization (HE) algorithm is a widely used contrast enhancement algorithm due to its effectiveness and simple implementation. But a drawback of HE algorithm is that the local contrast of an image cannot be equally enhanced. Local histogram equalization algorithms are proved to be the effective techniques for local image contrast enhancement. However, over-enhancement of noise and artifacts can be easily found in the local histogram equalization enhanced images. In this paper, a new contrast enhancement technique based on local histogram equalization algorithm is proposed to overcome the drawbacks mentioned above. The input images are segmented into three kinds of overlapped sub-blocks using the gradients of them. To overcome the over-enhancement effect, the histograms of these sub-blocks are then modified by adjacent sub-blocks. We pay more attention to improve the contrast of detail information while the brightness of the flat region in these sub-blocks is well preserved. It will be shown that the proposed algorithm outperforms other related algorithms by enhancing the local contrast without introducing over-enhancement effects and additional noise.

  2. The intrusive complexof the Island of Giglio: geomagnetic characteristics of plutonic facies with low susceptibility contrast

    Directory of Open Access Journals (Sweden)

    R. Cavallini

    1998-06-01

    Full Text Available Two main plutonic facies characterize the intrusive complex of the Island of Giglio, and the trend of their contact at depth has been modelled using a 2D½ analysis based on a detailed geomagnetic survey in order to verify the geological hypothesis of the subsurface geometry of this contact. The magnetic anomaly connected with the discontinuity is quite low, due to the small difference between the magnetic susceptibilities of the two granitic facies. Development of this model of inversion of the magnetic field, which is in good agreement with the geological interpretation, was made possible by: 1 accurate control of the geomagnetic time variations and consequent temporal reduction, 2 a very low level of the artificial magnetic noise, 3 high density of the magnetic survey, 4 detailed knowledge of the mapped geologic contact between facies and of their petrologic characteristics, and 5 direct local measurements of the magnetic susceptibilities of the key lithologies. The model shows the trends of the geological contact, as projected in three E-W sections, that dips eastward in the range between 210 and 540, supporting the geologic hypothesis that the Pietrabona facies represents an external shell of the shallowly emplaced Giglio monzogranite intrusion.

  3. Temporal adaptation enhances efficient contrast gain control on natural images.

    Directory of Open Access Journals (Sweden)

    Fabian Sinz

    Full Text Available Divisive normalization in primary visual cortex has been linked to adaptation to natural image statistics in accordance to Barlow's redundancy reduction hypothesis. Using recent advances in natural image modeling, we show that the previously studied static model of divisive normalization is rather inefficient in reducing local contrast correlations, but that a simple temporal contrast adaptation mechanism of the half-saturation constant can substantially increase its efficiency. Our findings reveal the experimentally observed temporal dynamics of divisive normalization to be critical for redundancy reduction.

  4. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  5. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Science.gov (United States)

    Wu, Shibin; Xie, Yaoqin

    2013-01-01

    A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE) and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR), and contrast improvement index (CII). PMID:24416072

  6. Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    K. Heath Martin

    2014-11-01

    Full Text Available For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.

  7. Contrast-enhanced ultrasound of histologically proven hepatic epithelioid hemangioendothelioma

    DEFF Research Database (Denmark)

    Dong, Yi; Wang, Wen-Ping; Cantisani, Vito

    2016-01-01

    %) in the arterial phase and hypoenhancement (25/25, 100%) in the portal venous and late phases (PVLP), a sign of malignancy. Eighteen patients showed central unenhanced areas (18/25, 72%); in seven patients (7/25, 28%), more lesions were detected in the PVLP. In contrast, all patients with hemangioma and focal...

  8. Contrast enhanced ultrasound in CT-undetermined focal liver lesions

    DEFF Research Database (Denmark)

    Sandrose, Sebastian; Karstrup, S.; Gerke, Oke

    2016-01-01

    . A total of 78 patients were evaluated: 41 men and 37 women, mean age 61.8 years; age range 30–91 years. All patients were examined with GE LOGIQ 9E ultrasound scanners with contrast-specific software, and SonoVue intravenous bolus. The standard of reference was composite consisting of: percutaneous biopsy...

  9. Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography.

    Science.gov (United States)

    Dromain, Clarisse; Balleyguier, Corrine; Muller, Serge; Mathieu, Marie-Christine; Rochard, France; Opolon, Paule; Sigal, Robert

    2006-11-01

    The purpose of this article is to assess the accuracy of contrast-enhanced digital mammography in the detection of breast carcinoma and to correlate the findings on the images with those of histologic analysis using microvessel quantification. Twenty patients with a suspicious breast abnormality underwent contrast-enhanced digital mammography using a full-field digital mammography unit that was modified to detect iodinated enhancement. For each patient, a total of six contrast-enhanced craniocaudal views were acquired from 30 seconds to 7 minutes after the injection of a bolus of 100 mL of an iodinated contrast agent. Image processing included a logarithmic subtraction and the analysis of enhancement kinetic curves. Contrast-enhanced digital mammography findings were compared with histologic analysis of surgical specimens, including intratumoral microvessel density quantification evaluated on CD34-immunostained histologic sections obtained from all patients. An area of enhancement was depicted on contrast-enhanced digital mammograms in 16 of the 20 histologically proven breast carcinomas. Excellent correlation was seen between the size of enhancement and the histologic size of tumors, which ranged from 9 to 22 mm. Early enhancement with washout was observed in four cases, early enhancement followed by a plateau in four cases, gradual enhancement in seven cases, and unexpected decrease of enhancement in one case. Intratumoral microvessel density ranged from 11.7 to 216.6 microvessels per square millimeter. A poor correlation was found between data measured on contrast-enhanced digital mammography and intratumoral microvessel density measured on CD34-immunostained histologic sections. Contrast-enhanced digital mammography is able to depict angiogenesis in breast carcinoma. Breast compression and projective images acquisition alter the quantitative assessment of enhancement parameters.

  10. Modified Global and Modified Linear Contrast Stretching Algorithms: New Colour Contrast Enhancement Techniques for Microscopic Analysis of Malaria Slide Images

    Science.gov (United States)

    Abdul-Nasir, Aimi Salihah; Mashor, Mohd Yusoff; Mohamed, Zeehaida

    2012-01-01

    Malaria is one of the serious global health problem, causing widespread sufferings and deaths in various parts of the world. With the large number of cases diagnosed over the year, early detection and accurate diagnosis which facilitates prompt treatment is an essential requirement to control malaria. For centuries now, manual microscopic examination of blood slide remains the gold standard for malaria diagnosis. However, low contrast of the malaria and variable smears quality are some factors that may influence the accuracy of interpretation by microbiologists. In order to reduce this problem, this paper aims to investigate the performance of the proposed contrast enhancement techniques namely, modified global and modified linear contrast stretching as well as the conventional global and linear contrast stretching that have been applied on malaria images of P. vivax species. The results show that the proposed modified global and modified linear contrast stretching techniques have successfully increased the contrast of the parasites and the infected red blood cells compared to the conventional global and linear contrast stretching. Hence, the resultant images would become useful to microbiologists for identification of various stages and species of malaria. PMID:23082089

  11. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference standard. Methods. An HDI 5000 Phillips ultrasound scanner with microvascular imaging software and 2.5 ml SonoVue (Bracco ...

  12. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  13. Blood Pool Agent Contrast-Enhanced MRA: Level-Set Based Artery-Vein Separation

    NARCIS (Netherlands)

    van Bemmel, C.M.; Spreeuwers, Lieuwe Jan; Verdonck, B.; Viergever, M.A.; Niessen, W.J.

    2002-01-01

    Blood pool agents (BPAs) for contrast-enhanced magnetic resonance angiography (CE-MRA) allow prolonged imaging times for higher contrast and resolution by imaging during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous arterial and

  14. Contrast-enhanced ultrasound in non-operative management of pancreatic injury in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Massimo; Sartoni Galloni, Stefania; Rimondi, Maria Rita; Barozzi, Libero [University Hospital S. Orsola-Malpighi, Emergency Department, Bologna (Italy); Gentili, Andrea [University Hospital S. Orsola-Malpighi, Department of Anaesthesia and Intensive Care, Bologna (Italy); Lima, Mario [University Hospital S. Orsola-Malpighi, Department of Paediatrics, Bologna (Italy)

    2006-06-15

    We report a 5-year-old child with pancreatic trauma from a blunt abdominal injury that was monitored with contrast-enhanced sonography. Unenhanced US failed to demonstrate the abnormality that was recognized by CT and MRI. The injury was well demonstrated by contrast-enhanced US which was therefore used for follow-up until its healing. (orig.)

  15. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...

  16. An evaluation of contrast enhancement techniques for mammographic breast masses.

    Science.gov (United States)

    Singh, Sameer; Bovis, Keir

    2005-03-01

    The main aim of this paper is to propose a novel set of metrics that measure the quality of the image enhancement of mammographic images in a computer-aided detection framework aimed at automatically finding masses using machine learning techniques. Our methodology includes a novel mechanism for the combination of the metrics proposed into a single quantitative measure. We have evaluated our methodology on 200 images from the publicly available digital database for screening mammograms. We show that the quantitative measures help us select the best suited image enhancement on a per mammogram basis, which improves the quality of subsequent image segmentation much better than using the same enhancement method for all mammograms.

  17. Contrast-enhanced sonography for detection of secondary lymph nodes in a melanoma tumor animal model.

    Science.gov (United States)

    Liu, Ji-Bin; Merton, Daniel A; Berger, Adam C; Forsberg, Flemming; Witkiewicz, Agnieszka; Zhao, Hongjia; Eisenbrey, John R; Fox, Traci B; Goldberg, Barry B

    2014-06-01

    To investigate the use of contrast-enhanced ultrasound imaging (US) for detection of secondary lymph nodes (LNs) in a naturally occurring melanoma swine model compared to surgery and pathologic assessment. Twenty-seven Sinclair swine were studied. The perfluorobutane microbubble contrast agent Sonazoid (GE Healthcare, Oslo, Norway) was administered (1.0 mL total dose) around the melanoma, and contrast-enhanced US was used to localize contrast-enhanced sentinel lymph nodes (SLNs). Then Sonazoid (dose, 0.25-1.0 mL) was injected into the SLNs to detect contrast-enhanced efferent lymphatic channels and secondary LNs. After peritumoral injection of blue dye, a surgeon (blinded to the contrast-enhanced US results) performed a radical LN dissection. Contrast-enhanced US was used to guide removal of any enhanced secondary LNs left after radical LN dissection. Clustered conditional logistic regression analyzed the benefit of contrast-enhanced US-directed secondary LN dissection over radical LN dissection using pathologic findings as the reference standard. A total of 268 secondary LNs were resected, with 59 (22%) containing metastases. Contrast-enhanced US detected 92 secondary LNs; 248 were identified by radical LN dissection; and 68 were identified by both methods. Metastases were detected in 20% (51 of 248) and 40% (37 of 92) of the secondary LNs identified by radical LN dissection and contrast-enhanced US, respectively. Thus, secondary LNs detected by contrast-enhanced US were nearly 5 times more likely to contain metastases than secondary LNs removed by radical LN dissection (odds ratio, 4.8; P < .0001). Twenty-two of the 180 secondary LNs (12%) identified only by radical LN dissection contained metastases, whereas contrast-enhanced US identified 20 secondary LNs after the surgeon completed the radical LN dissection, of which 8 (40%) contained metastases. Secondary LNs can be detected by using contrast-enhanced US after injection of Sonazoid into SLNs. Secondary LNs

  18. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis

    Science.gov (United States)

    Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.

    2017-08-01

    Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.

  19. Contrast enhanced MR imaging of female pelvic cancers: Established methods and emerging applications

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit, E-mail: shonit.punwani@gmail.com [Department of Academic Radiology, 2nd Floor Podium, University College London Hospital, 235 Euston Road, London NW1 2BU (United Kingdom)

    2011-04-15

    Contrast enhanced magnetic resonance imaging of female pelvic cancers has been established for over 20 years. Conventional contrast enhanced imaging involves acquiring a set of pre-contrast T1 weighted images, followed by intravenous injection of an gadolinium based contrast agent and subsequent acquisition of a second set of contrast enhanced images. Developments in MR hardware and pulse sequences over the last 10 years have made dynamic contrast enhanced (DCE) protocols possible. DCE-MRI entails imaging of the same volume repeatedly prior to, during and following contrast injection. There have also been developments in image analysis methods and tools to reflect the increased data acquired. Qualitative analysis of contrast enhanced imaging (whether a single set or temporal series) by radiologists remains the mainstay for clinical reporting. Semi-quantitative assessment of signal intensity versus time curves and full pharmacokinetic modelling methods have emerged for evaluation of DCE-MRI data. DCE-MRI has found an established role in the detection, localisation and staging of female pelvic malignancies. Emerging applications of DCE-MRI include assessment of tumour grade, histology prior to and following treatment and prediction of individual and final treatment outcome. This article reviews the biophysical basis of contrast enhancement, the technical aspects of performance and analysis of DCE-MRI studies, and the established and emerging clinical utility of DCE-MRI in female pelvic malignancies.

  20. Evaluation of breast lesions with contrast-enhanced ultrasound using the microvascular imaging technique: initial observations.

    Science.gov (United States)

    Liu, He; Jiang, Yu-Xin; Liu, Ji-Bin; Zhu, Qing-Li; Sun, Qiang

    2008-10-01

    The objective of this study was to evaluate the usefulness of contrast-enhanced ultrasound using the microvascular imaging technique in the diagnosis of breast lesions. In 104 patients with 104 breast lesions scheduled for surgery, conventional and contrast-enhanced ultrasound using the microvascular imaging technique were performed after administration of SonoVue. The enhancement patterns of breast lesions were classified as no enhancement, peripheral enhancement, homogeneous enhancement, regional enhancement, or heterogeneous enhancement based on the morphologic features of enhancement. The diagnostic value of contrast-enhanced ultrasound using the microvascular imaging technique was analyzed with the observers blinded to the clinical data and pathology (which served as the gold standard). None of the enhancement patterns was suggestive of benignity, with a sensitivity of 18.3%, specificity of 97.7%, positive predictive value (PPV) of 91.7%, negative predictive value (NPV) of 46.2%, and accuracy of 51.5%. The peripheral enhancement pattern was suggestive of malignancy, with a sensitivity of 39.5%, specificity of 98.3%, PPV of 94.4%, NPV of 69.4%, and accuracy of 73.8%. Homogeneous, regional, and heterogeneous enhancement patterns did not show meaningful diagnostic information. Contrast-enhanced ultrasound using the microvascular imaging technique provides diagnostic information on breast lesions.

  1. Enhanced susceptibility to a chemical carcinogen in rats carrying MHC-linked genes influencing development (GRC).

    Science.gov (United States)

    Rao, K N; Shinozuka, H; Kunz, H W; Gill, T J

    1984-07-15

    In an approach to testing the possible relationship between embryogenesis and carcinogenesis, we examined the susceptibility of rats carrying the grc, which is an MHC-linked gene complex affecting growth and development, to the development of the cellular and biochemical changes known to be associated with the induction of cancer. Genetically related strains which differed mainly by the presence or absence of the grc were fed a diet containing 0.02% N-2-acetylaminofluorene (AAF), and the induction of gamma-glutamyltranspeptidase (GGT)-positive foci, bile-duct proliferation and oval-cell proliferation in the livers of the two groups of animals were scored. All of the rats homozygous for the grc displayed GGT-positive foci (from three to six per section) and extensive bile-duct and oval-cell proliferation. By contrast, only 27% of the animals which did not carry the grc had GGT-positive foci in the liver, and these were present in smaller numbers (from one to three per section); there was no bile-duct or oval-cell proliferation. Biochemical studies of the liver and testes showed that the grc homozygotes had the metabolic abnormalities associated with the development of cancer: increased cholesterol biosynthesis; increased DNA synthesis, as indicated by an enhanced incorporation of 3H-thymidine into DNA; stimulation of the hexose monophosphate (HMP) pathway, as indicated by increased levels of glucose-6-phosphate dehydrogenase (G6PD) and 6-phosphogluconate dehydrogenase (6PGD); and decreased levels of circulating lipoproteins. Both the morphological response of the rats carrying the grc to feeding AAF and the biochemical abnormalities that exist in these animal are consistent with the changes which eventually lead to cancer. Thus, there appears to be a relationship in rats between aberrations in the control of growth and development, susceptibility to the chemical induction of cancer and the control of cholesterol biosynthesis.

  2. High Atomic Number Contrast Media Offer Potential for Radiation Dose Reduction in Contrast-Enhanced Computed Tomography.

    Science.gov (United States)

    Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A

    2016-04-01

    Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.

  3. Anemia and the risk of contrast-induced nephropathy in patients with renal insufficiency undergoing contrast-enhanced MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Ryusuke, E-mail: rywakana@nms.ac.jp; Kumita, Shin-ichiro; Hayashi, Hiromitsu; Sugizaki, Ken-ichi; Okazaki, Emi; Kiriyama, Tomonari; Hakozaki, Kenta; Tani, Hitomi; Miki, Izumi; Takeda, Minako

    2013-10-01

    Purpose: The purpose of this study was to assess the effect of anemia on the incidence of contrast-induced nephropathy (CIN) in patients with renal impairment undergoing MDCT. Materials and methods: Institutional review board approval was waived for this retrospective review of 843 patients with stable renal insufficiency (eGFR between 15 and 60 mL/min) who had undergone contrast-enhanced MDCT. Baseline hematocrit and hemoglobin values were measured. Serum creatinine (SCr) was assessed at the baseline and at 48–72 h after contrast administration. Results: The overall incidence of CIN in the patient population with renal insufficiency was 6.9%. CIN developed in 7.8% (54 of 695) of anemic patients, and in 2.8% (4 of 148) of non-anemic patients (P = .027). After adjustment for confounders, low hemoglobin and low hematocrit values remained independent predictors of CIN (odds ratio 4.6, 95% CI 1.0–20.5, P = .046). Conclusions: Anemia is associated with a higher incidence of CIN in patients with renal insufficiency. Anemia is a potentially modifiable risk factor for CIN, and has an unfavorable impact on prognosis in patients with renal insufficiency undergoing contrast-enhanced MDCT.

  4. An Improved Local Equilibrium Contrast Enhancement Algorithm for Infrared Laser Images

    OpenAIRE

    Yuhong Li; Jianzhong Zhou; Wei Ding; Shan Ding

    2010-01-01

    An improved local equilibrium contrast enhancement algorithm based self-adaptive contrast enhancement algorithm is proposed for infrared laser images, in which the image pixel value histogram is divided into three parts: background and noise area, targets area, and uninterested area. The targets parts are highlighted, while the background and noise parts and the uninterested parts are restrained. A comprehensive qualitative and quantitative image enhancement performance evaluation is presente...

  5. Characterization of solitary pulmonary nodules: Use of washout characteristics at contrast-enhanced computed tomography

    OpenAIRE

    YE, XIAO-DAN; YE, JIAN-DING; YUAN, ZHENG; DONG, SHENG; XIAO, XIANG-SHENG

    2011-01-01

    The purpose of this study was to determine whether computed tomographic scans and attenuation measurements on contrast material-enhanced and non-enhanced computed tomographic scans could be used to characterize solitary pulmonary nodules and, in particular, to characterize these lesions using washout characteristics on contrast-enhanced computed tomography. A total of 63 patients (38 males, 25 females; age range, 21–80 years; mean age, 58±13.2 years) with pulmonary nodules revealed on contras...

  6. Identifying the association between contrast enhancement pattern, surgical resection, and prognosis in anaplastic glioma patients

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yinyan; Jiang, Tao [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Capital Medical University, Beijing Neurosurgical Institute, Beijing (China); Wang, Kai; Li, Shaowu; Ma, Jun [Capital Medical University, Department of Neuroradiology, Beijing Tiantan Hospital, Beijing (China); Wang, Jiangfei [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Dai, Jianping [Capital Medical University, Beijing Neurosurgical Institute, Beijing (China); Capital Medical University, Department of Neuroradiology, Beijing Tiantan Hospital, Beijing (China)

    2016-04-15

    Contrast enhancement observable on magnetic resonance (MR) images reflects the destructive features of malignant gliomas. This study aimed to investigate the relationship between radiologic patterns of tumor enhancement, extent of resection, and prognosis in patients with anaplastic gliomas (AGs). Clinical data from 268 patients with histologically confirmed AGs were retrospectively analyzed. Contrast enhancement patterns were classified based on preoperative T1-contrast MR images. Univariate and multivariate analyses were performed to evaluate the prognostic value of MR enhancement patterns on progression-free survival (PFS) and overall survival (OS). The pattern of tumor contrast enhancement was associated with the extent of surgical resection in AGs. A gross total resection was more likely to be achieved for AGs with focal enhancement than those with diffuse (p = 0.001) or ring-like (p = 0.024) enhancement. Additionally, patients with focal-enhanced AGs had a significantly longer PFS and OS than those with diffuse (log-rank, p = 0.025 and p = 0.031, respectively) or ring-like (log-rank, p = 0.008 and p = 0.011, respectively) enhanced AGs. Furthermore, multivariate analysis identified the pattern of tumor enhancement as a significant predictor of PFS (p = 0.016, hazard ratio [HR] = 1.485) and OS (p = 0.030, HR = 1.446). Our results suggested that the contrast enhancement pattern on preoperative MR images was associated with the extent of resection and predictive of survival outcomes in AG patients. (orig.)

  7. Facing Contrast-Enhancing Gliomas: Perfusion MRI in Grade III and Grade IV Gliomas according to Tumor Area

    Directory of Open Access Journals (Sweden)

    Anna Luisa Di Stefano

    2014-01-01

    Full Text Available Tumoral neoangiogenesis characterizes high grade gliomas. Relative Cerebral Blood Volume (rCBV, calculated with Dynamic Susceptibility Contrast (DSC Perfusion-Weighted Imaging (PWI, allows for the estimation of vascular density over the tumor bed. The aim of the study was to characterize putative tumoral neoangiogenesis via the study of maximal rCBV with a Region of Interest (ROI approach in three tumor areas—the contrast-enhancing area, the nonenhancing tumor, and the high perfusion area on CBV map—in patients affected by contrast-enhancing glioma (grades III and IV. Twenty-one patients were included: 15 were affected by grade IV and 6 by grade III glioma. Maximal rCBV values for each patient were averaged according to glioma grade. Although rCBV from contrast-enhancement and from nonenhancing tumor areas was higher in grade IV glioma than in grade III (5.58 and 2.68; 3.01 and 2.2, resp., the differences were not significant. Instead, rCBV recorded in the high perfusion area on CBV map, independently of tumor compartment, was significantly higher in grade IV glioma than in grade III (7.51 versus 3.78, P=0.036. In conclusion, neoangiogenesis encompasses different tumor compartments and CBV maps appear capable of best characterizing the degree of neovascularization. Facing contrast-enhancing brain tumors, areas of high perfusion on CBV maps should be considered as the reference areas to be targeted for glioma grading.

  8. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Lavini, Cristina; Hemke, Robert; Caan, Matthan W.A.; Maas, Mario [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Dolman, Koert M. [Sint Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands); Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Rossum, Marion A.J. van [Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Emma Children' s Hospital, Department of Pediatrics, Academic Medical Center, Amsterdam (Netherlands)

    2017-02-15

    Dynamic contrast-enhanced MRI provides information on the heterogeneity of the synovium, the primary target of disease in children with juvenile idiopathic arthritis (JIA). To evaluate the feasibility of dynamic contrast-enhanced MRI in the wrist of children with JIA using conventional descriptive measures and time-intensity-curve shape analysis. To explore the association between enhancement characteristics and clinical disease status. Thirty-two children with JIA and wrist involvement underwent dynamic contrast-enhanced MRI with movement-registration and were classified using validated criteria as clinically active (n = 27) or inactive (n = 5). Outcome measures included descriptive parameters and the classification into time-intensity-curve shapes, which represent the patterns of signal intensity change over time. Differences in dynamic contrast-enhanced MRI outcome measures between clinically active and clinically inactive disease were analyzed and correlation with the Juvenile Arthritis Disease Activity Score was determined. Comprehensive evaluation of disease status was technically feasible and the quality of the dynamic dataset was improved by movement registration. The conventional descriptive measure maximum enhancement differed significantly between clinically active and inactive disease (P = 0.019), whereas time-intensity-curve shape analysis showed no differences. Juvenile Arthritis Disease Activity Score correlated moderately with enhancing volume (P = 0.484). Dynamic contrast-enhanced MRI is a promising biomarker for evaluating disease status in children with JIA and wrist involvement. Conventional descriptive dynamic contrast-enhanced MRI measures are better associated with clinically active disease than time-intensity-curve shape analysis. (orig.)

  9. Effects of noradrenaline and adenosine triphosphate on the degree on contrast enhancement in a rabbit model of atherosclerosis during contrast-enhanced ultrasonography.

    Science.gov (United States)

    Sun, Jie; Deng, You-Bin; Liu, Kun; Wang, Yu-Bo

    2014-11-01

    The aim of the study is to assess the effects of vasoactive agents on the degree of contrast enhancement in experimental atherosclerotic plaque during contrast-enhanced ultrasonography (CEUS). Abdominal aortic atherosclerosis was induced in 25 New Zealand white rabbits by a combination of cholesterol-rich diet and balloon endothelial denudation. Standard ultrasonography and CEUS were performed at baseline and during intravenous infusion of noradrenaline or adenosine triphosphate (ATP). The degree of contrast enhancement of the plaque after injection of contrast material was quantified by calculating the enhanced intensity in the plaque. The infusion of noradrenaline induced significant increase in systolic blood pressure (84 ± 13 mm Hg vs. 112 ± 20 mm Hg, p = 0.011) and significant decrease in the enhanced intensity in the plaque (7.52 ± 1.32 dB vs. 5.88 ± 1.33 dB, p < 0.001) during CEUS. The infusion of ATP resulted in the significant decrease in systolic blood pressure (80 ± 13 mm Hg vs. 65 ± 11 mm Hg, p = 0.005) and increase in the enhanced intensity in the plaque (7.52 ± 1.32 dB vs. 8.84 ± 1.55 dB, p < 0.001) during CEUS. The degree of contrast enhancement within an experimental atherosclerotic plaque during CEUS can be influenced by vasoactive agents and hemodynamic status. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Rapid bacterial antibiotic susceptibility test based on simple surface-enhanced Raman spectroscopic biomarkers

    OpenAIRE

    Chia-Ying Liu; Yin-Yi Han; Po-Han Shih; Wei-Nan Lian; Huai-Hsien Wang; Chi-Hung Lin; Po-Ren Hsueh; Juen-Kai Wang; Yuh-Lin Wang

    2016-01-01

    Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploi...

  11. Host selection and probing behavior of the poplar aphid Chaitophorus leucomelas (Sternorrhyncha: Aphididae) on two poplar hybrids with contrasting susceptibility to aphids.

    Science.gov (United States)

    Barrios-San Martín, Joceline; Quiroz, Andrés; Verdugo, Jaime A; Parra, Leonardo; Hormazabal, Emilio; Astudillo, Luis A; Rojas-Herrera, Marcelo; Ramírez, Claudio C

    2014-02-01

    Poplars are frequently attacked by aphids. The differential susceptibility of poplar hybrids to the aphid Chaitophorus leucomelas Koch (Sternorrhyncha: Aphididae) has been described, but the mechanism underlying this pattern is unknown. This work tested the hypothesis that poplar resistance to this aphid is associated with the presence of volatiles and secondary plant compounds that affect host selection and feeding behavior. This hypothesis was tested by studying the host choice and feeding behavior of C. leucomelas on two poplar hybrids with contrasting susceptibilities to this aphid ([Populus trichocarpa Torrey & Gray x Populus deltoides Bartram ex Marshall] x P. deltoides [TD x D], and [P. trichocarpa x Populus maximowiczii Henry] x [P. trichocarpa x P. maximowiczii] [TM x TM]). The results showed that C. leucomelas rejected leaves of the TM x TM hybrid and did not prefer odors from either hybrid. Electronic monitoring of the probing behavior of C. leucomelas suggested the involvement of antifeedant factors in the TM x TM hybrid. In addition, the chemical characterization of volatiles, epicuticular waxes, and internal phenols of leaves from both poplar hybrids revealed that TM x TM had a higher abundance of monoterpenes, sesquiterpenes, n-alkanes, and phenols. These results are discussed in terms of their contribution to poplar breeding programs aimed at enhancing insect resistance.

  12. CT Angiography: Post-processed Contrast Enhancement for Improved Detection of Pulmonary Embolism.

    Science.gov (United States)

    Muenzel, Daniela; Fingerle, Alexander A; Zahel, Tina; Sauter, Andreas; Vlassenbroek, Alain; Dobritz, Martin; Rummeny, Ernst J; Noël, Peter B

    2017-02-01

    The study aimed to improve the detection of pulmonary embolism via an iodine contrast enhancement tool in patients who underwent suboptimal enhanced computed tomography angiography (CTA). We evaluated the CT examinations of 41 patients who underwent CTA for evaluation of the pulmonary arteries which suffered from suboptimal contrast enhancement. The contrast enhancement of the reconstructed images was increased via a post-processing tool (vContrast). Image noise and contrast-to-noise ratio (CNR) were assessed in eight different regions: main pulmonary artery, right and left pulmonary arteries, right and left segment arteries, muscle, subcutaneous fat, and bone. For subjective image assessment, three experienced radiologists evaluated the diagnostic quality. While employing the post-processing algorithm, the CNR for contrast-filled lumen and thrombus/muscle improves significantly by a factor of 1.7 (CNR without vContrast = 8.48 ± 6.79/CNR with vContrast = 14.46 ± 5.29) (P image analysis illustrated a significant improvement using post-processing for clinically relevant criteria such as diagnostic confidence. vContrast makes CT angiograms with inadequate contrast applicable for diagnostic evaluation, offering an improved visualization of the pulmonary arteries. In addition, vContrast can help in the significant reduction of the iodine contrast material. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. A comparative study on preprocessing techniques in diabetic retinopathy retinal images: illumination correction and contrast enhancement.

    Science.gov (United States)

    Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza

    2015-01-01

    To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.

  14. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  15. Comparison of Different Post-Processing Algorithms for Dynamic Susceptibility Contrast Perfusion Imaging of Cerebral Gliomas.

    Science.gov (United States)

    Kudo, Kohsuke; Uwano, Ikuko; Hirai, Toshinori; Murakami, Ryuji; Nakamura, Hideo; Fujima, Noriyuki; Yamashita, Fumio; Goodwin, Jonathan; Higuchi, Satomi; Sasaki, Makoto

    2017-04-10

    The purpose of the present study was to compare different software algorithms for processing DSC perfusion images of cerebral tumors with respect to i) the relative CBV (rCBV) calculated, ii) the cutoff value for discriminating low- and high-grade gliomas, and iii) the diagnostic performance for differentiating these tumors. Following approval of institutional review board, informed consent was obtained from all patients. Thirty-five patients with primary glioma (grade II, 9; grade III, 8; and grade IV, 18 patients) were included. DSC perfusion imaging was performed with 3-Tesla MRI scanner. CBV maps were generated by using 11 different algorithms of four commercially available software and one academic program. rCBV of each tumor compared to normal white matter was calculated by ROI measurements. Differences in rCBV value were compared between algorithms for each tumor grade. Receiver operator characteristics analysis was conducted for the evaluation of diagnostic performance of different algorithms for differentiating between different grades. Several algorithms showed significant differences in rCBV, especially for grade IV tumors. When differentiating between low- (II) and high-grade (III/IV) tumors, the area under the ROC curve (Az) was similar (range 0.85-0.87), and there were no significant differences in Az between any pair of algorithms. In contrast, the optimal cutoff values varied between algorithms (range 4.18-6.53). rCBV values of tumor and cutoff values for discriminating low- and high-grade gliomas differed between software packages, suggesting that optimal software-specific cutoff values should be used for diagnosis of high-grade gliomas.

  16. Non-enhanced MR angiography of renal arteries - Comparison with contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Angeretti, M. G.; Lumia, D.; Cani, A.; Barresi, M.; Cardim, L Nocchi; Piacentino, F.; Genovese, E. A.; Fugazzola, C. [Dept. of Radiology, Insubria Univ., Ospedale di Circolo e Fondazione Macchi, Varese (Italy)], e-mail: laranocchi@gmail.com; Maresca, A. M. [Dept. of Internal Medicine, Insubria Univ., Ospedale di Circolo e Fondazione Macchi, Varese (Italy); Novario, R. [Dept. of Medical Physics, Insubria Univ., Ospedale di Circolo e Fondazione Macchi, Varese (Italy)

    2013-09-15

    Background: The main causes of renal artery stenosis (RAS) are atherosclerosis and fibromuscular dysplasia. Despite contrast-enhanced magnetic resonance angiography (CE-MRA) being a safe and reliable method for diagnosis of RAS especially in young individuals, recently it has been possible to adopt innovative technologies that do not require paramagnetic contrast agents. Purpose: To assess the accuracy of steady-state free-precession (SSFP) non-contrast-enhanced magnetic resonance angiography (NC-MRA) by using a 1.5 T MR scanner for the detection of renal artery stenosis, in comparison with breath-hold CE-MRA as the reference standard. Material and Methods: Sixty-three patients (33 men, 30 women) with suspected renovascular hypertension (RVHT) were examined by a 1.5T MR scanner; NC-MRA with an electrocardiography (ECG)-gated SSFP sequence was performed in 58.7% (37/63) of patients; in 41.3% (26/63) of patients a respiratory trigger was used in addition to cardiac gating. CE-MRA, with a three-dimensional gradient echo (3D-GRE) T1-weighted sequence, was performed in all patients within the same session. Maximum intensity projection (MIP) image quality, number of renal arteries, and the presence of stenosis were assessed by two observers (independently for NC-MRA and together for CE-MRA). The agreement between NC-MRA and CE-MRA as well as the inter-observer reproducibility were calculated with Bland-Altman plots. Results: MIP image quality was considered better for NC-MRA. NC-MRA identified 143 of 144 (99.3%) arteries detected by CE-MRA (an accessory artery was not identified). Fourteen stenoses were detected by CE-MRA (11 atherosclerotic, 3 dysplastic) with four of 14 (28.5%) significant stenosis. Bland-Altman plot demonstrated an excellent concordance between NC-MRA and CE-MRA; particularly, the reader A evaluated correctly all investigated arteries, while over-estimation of two stenoses occurred for reader B. Regarding NC-MRA, inter-observer agreement was excellent

  17. Portal biliopathy diagnosed using color Doppler and contrast-enhanced ultrasound.

    Science.gov (United States)

    Nunoi, Hiroaki; Hirooka, Masashi; Ochi, Hironori; Koizumi, Yohei; Tokumoto, Yoshio; Abe, Masanori; Tada, Fujimasa; Ikeda, Yoshio; Matsuura, Bunzo; Tanaka, Hiroaki; Tsuda, Takaharu; Mochizuki, Teruhito; Hiasa, Yoichi; Onji, Morikazu

    2013-01-01

    Portal biliopathy is a morphological abnormality of the biliary ductal and gallbladder wall associated with portal hypertension. A patient with essential thrombocythemia was initially diagnosed with extrahepatic portal vein obstruction (EHPVO). The contrast-enhanced computed tomography (CT) findings were similar to those of cholangiocarcinoma or sclerosing cholangitis. However, color Doppler and contrast-enhanced ultrasound (US) were more specific. The paracholedocheal veins around the bile ducts appeared as beads soon after the injection of contrast medium, followed by linear enhancement of the epicholedochal veins and the gradual enhancement of the whole bile ducts. These findings led to a diagnosis of portal biliopathy, which prevented the patient from having to endure hazardous procedures such as bile duct biopsies. Color Doppler and contrast-enhanced US findings are useful for diagnosing or ruling out portal biliopathy in patients who present with EHPVO.

  18. Description of the use of contrast-enhanced ultrasonography in four dogs with pancreatic tumours.

    Science.gov (United States)

    Vanderperren, K; Haers, H; Van der Vekens, E; Stock, E; Paepe, D; Daminet, S; Saunders, J H

    2014-03-01

    Canine pancreatic tumours are rare compared to human medicine and the detection and differentiation of pancreatic neoplasia is challenging with B-mode ultrasonography, which often leads to late clinical diagnosis and poor prognosis. This case report describes the findings of contrast-enhanced ultrasonography in four dogs with pancreatic adenocarcinoma or insulinoma. B-mode ultrasonography of the pancreas revealed a hypoechoic nodule in three dogs and heterogenous tissue in one dog. Contrast-enhanced ultrasonography was able to differentiate between two tumour types: adenocarcinomas showed hypoechoic and hypovascular lesions, whereas insulinomas showed uniformly hypervascular lesions. Contrast-enhanced ultrasonography findings were confirmed by cytology and/or histopathology. The results demonstrated that contrast-enhanced ultrasonography was able to establish different enhancement patterns between exocrine (adenocarcinoma) and endocrine (insulinoma) tumours in dogs.

  19. Susceptibility-weighted imaging using inter-echo-variance channel combination for improved contrast at 7 tesla.

    Science.gov (United States)

    Hosseini, Zahra; Liu, Junmin; Solovey, Igor; Menon, Ravi S; Drangova, Maria

    2017-04-01

    To implement and optimize a new approach for susceptibility-weighted image (SWI) generation from multi-echo multi-channel image data and compare its performance against optimized traditional SWI pipelines. Five healthy volunteers were imaged at 7 Tesla. The inter-echo-variance (IEV) channel combination, which uses the variance of the local frequency shift at multiple echo times as a weighting factor during channel combination, was used to calculate multi-echo local phase shift maps. Linear phase masks were combined with the magnitude to generate IEV-SWI. The performance of the IEV-SWI pipeline was compared with that of two accepted SWI pipelines-channel combination followed by (i) Homodyne filtering (HPH-SWI) and (ii) unwrapping and high-pass filtering (SVD-SWI). The filtering steps of each pipeline were optimized. Contrast-to-noise ratio was used as the comparison metric. Qualitative assessment of artifact and vessel conspicuity was performed and processing time of pipelines was evaluated. The optimized IEV-SWI pipeline (σ = 7 mm) resulted in continuous vessel visibility throughout the brain. IEV-SWI had significantly higher contrast compared with HPH-SWI and SVD-SWI (P IEV-SWI pipeline processed a six-echo 16-channel dataset in under 10 min. IEV-SWI benefits from channel-by-channel processing of phase data and results in high contrast images with an optimal balance between contrast and background noise removal, thereby presenting evidence of importance of the order in which postprocessing techniques are applied for multi-channel SWI generation. 2 J. Magn. Reson. Imaging 2017;45:1113-1124. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Ablation zone visualization enhancement by periodic contrast-enhancement computed tomography during microwave ablation.

    Science.gov (United States)

    Wu, Po-Hung; Borden, Zachary; Brace, Christopher L

    2017-06-01

    Intra-procedural contrast-enhanced computed tomography (CECT) has been proposed to monitor the growth of thermal ablations. The primary challenge with multiple CT acquisitions is reducing radiation dose while maintaining sufficient image quality. The purpose of this study was to evaluate the feasibility of applying local highly constrained backprojection reconstruction (HYPR-LR) on periodic CECT images acquired with low-dose protocols, and to determine whether the ablations visible on CT were commensurate to gross pathology. Low-dose (CTDIvol≤1.49mGy), temporal CECT volumes were acquired during microwave ablation on normal porcine liver. HYPR processing was performed on each volume after image registration. Ablation signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were collected to evaluate the degree of enhancement of image quality and ablation zone visualization. Ablation zones were manually segmented on HYPR and non-HYPR images and compared spatially using Dice's coefficient. The dimensions of ablation zones were also compared to gross pathology by correlation and dimensional differences. The SNR and CNR of ablation zones were increased after HYPR processing. The manually segmented ablation zone was highly similar to gross pathology with a Dice coefficient of 0.81 ± 0.03, while the low-dose CECT had a smaller Dice coefficient of 0.72 ± 0.05. Both HYPR and low-dose CECT had high correlation to gross pathology (0.99 and 0.94, respectively), but the variance of measurements were lower after HYPR processing compared to unprocessed images. The relative difference in area, length of long axis, and length of short axis for HYPR image were 13.1 ± 5.6%, 9.7 ± 4.2%, and 15.2 ± 2.8%, which were lower than those for low-dose CECT at 37.5 ± 6.0%, 17.7 ± 2.8%, and 28.9 ± 5.4%. HYPR processing applied to periodic CECT images can enhance ablation zone visualization. HYPR processing may potentially enable CECT in real-time ablation monitoring under strict

  1. Contrast-Enhanced Sonography for Diagnosing Collateral Transformation of the Hepatic Artery After Liver Transplantation.

    Science.gov (United States)

    Lyu, Su-Qin; Ren, Jie; Zheng, Rong-Qin; Meng, Xiao-Chun; Huang, Ming-Sheng; Wang, Ping

    2015-09-01

    To determine the contrast-enhanced sonographic features of hepatic artery collateral transformation in patients with hepatic artery complications after liver transplantation. Ninety-nine liver transplant recipients who underwent contrast-enhanced sonography were recruited from April 2004 to May 2014. The reference standards were conventional angiography and computed tomographic angiography. The contrast-enhanced sonographic features of the hepatic artery in patients with and without collateral arteries were retrospectively analyzed. All 15 patients with hepatic artery collateral transformation had hepatic artery thrombosis (10 of 15) or hepatic artery stenosis (5 of 15). The collateral artery detection rate on contrast-enhanced sonography was 100%. The peripheral hepatic artery could not be visualized by contrast-enhanced sonography in most of the patients with hepatic artery collateral transformation (14 of 15). Additionally, many small tortuous collateral arteries in the porta hepatis region were visualized during the arterial and early portal phases, showing reticulated/patchy (15 of 15) and striped (3 of 15) enhancement patterns on contrast-enhanced sonography. Collateral transformation of the hepatic artery in patients with hepatic artery complications after liver transplantation appears to have characteristic features on contrast-enhanced sonography, especially a reticulated or patchy enhancement pattern in the porta hepatis region during the arterial and early portal phases combined with the absence of the peripheral hepatic artery. Contrast-enhanced sonography may be a novel method for diagnosing hepatic artery collateral transformation, which may be a highly specific sign of hepatic artery thrombosis or stenosis. © 2015 by the American Institute of Ultrasound in Medicine.

  2. Histological change and microcirculation in the contrast-enhancement region of cerebral infarction. An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Tetsuya; Takemura, Kiyoshi; Sakaki, Toshisuke; Hori, Yutaka (Nara National Hospital, Nara (Japan)); Yokoyama, Kazuhiro

    1983-08-01

    The purpose of this experiment is to reveal the microcirculation and blood-brain barrier by comparison with the histological findings in the contrast-enhancement region. The microcirculation is studied by carbon perfusion, and the function of the blood-brain barrier is studied by the intravenous administration of fluorescein. According to the carbon perfusion, carbon filling is impaired in the ischemic region of cerebral infarction. However, partially in the ischemic region, there is a good carbon-filling zone, called the carbon deposit, which indicates that the microcirculation develops better in this part of the ischemic region during the contrast-enhancement stage. From the histological point of view, the contrast-enhancement region contains capillaries and phagocytes and has a spongy appearance, an extravasation of red cells, and cavity formations. The density of capillaries might play the most important role in the microcirculation and the function of the blood-brain barrier. The fluorescein stain indicates the extent of the abnormally increased permeability of the capillaries. During the contrast-enhancement stage, the fluorescein stain is found not only in the contrast-enhacement region, but also in the surrounding zone around the contrast-enhancement region. There is an ischemic histological change, shown by the spongy appearance in this surrounding zone with the fluorescein stain. On a CT scan, this surrounding zone is seen as a normodensity area in most experimental models. These results indicate that, during the stage of the contrast-enhancement of cerebral infarction, a histologically evidenced ischemic area is detected not only as a contrast-enhancement region but also as a normodensity area around the contrast-enhancement region.

  3. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T.; Naganawa, S.; Fukatsu, H.; Sakurai, Y.; Ishigaki, T. [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, 466-8550, Shouwa-ku, Nagoya (Japan); Aoki, I.; Ninomiya, A. [Medical Systems Company, Toshiba Corporation, Nasu Operations, Otawara-shi, Tochigi (Japan); Nakashima, T. [Department of Otorhinolaryngology, Nagoya University School of Medicine, Shouwa-ku, Nagoya (Japan)

    2003-09-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  4. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    CERN Document Server

    Pavlicek, M

    2000-01-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time ...

  5. Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging.

    Directory of Open Access Journals (Sweden)

    Shailesh B Raval

    Full Text Available The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity].A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization].High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The

  6. Novel nano-sized MR contrast agent mediates strong tumor contrast enhancement in an oncogene-driven breast cancer model.

    Directory of Open Access Journals (Sweden)

    Per-Olof Eriksson

    Full Text Available The current study was carried out to test the potential of a new nanomaterial (Spago Pix as a macromolecular magnetic MR contrast agent for tumor detection and to verify the presence of nanomaterial in tumor tissue. Spago Pix, synthesized by Spago Nanomedical AB, is a nanomaterial with a globular shape, an average hydrodynamic diameter of 5 nm, and a relaxivity (r1 of approximately 30 (mM Mn-1 s-1 (60 MHz. The material consists of an organophosphosilane hydrogel with strongly chelated manganese (II ions and a covalently attached PEG surface layer. In vivo MRI of the MMTV-PyMT breast cancer model was performed on a 3 T clinical scanner. Tissues were thereafter analyzed for manganese and silicon content using inductively coupled plasma-atomic emission spectroscopy (ICP-AES. The presence of nanomaterial in tumor and muscle tissue was assessed using an anti-PEG monoclonal antibody. MR imaging of tumor-bearing mice (n = 7 showed a contrast enhancement factor of 1.8 (tumor versus muscle at 30 minutes post-administration. Contrast was retained and further increased 2-4 hours after administration. ICP-AES and immunohistochemistry confirmed selective accumulation of nanomaterial in tumor tissue. A blood pharmacokinetics analysis showed that the concentration of Spago Pix gradually decreased over the first hour, which was in good agreement with the time frame in which the accumulation in tumor occurred. In summary, we demonstrate that Spago Pix selectively enhances MR tumor contrast in a clinically relevant animal model. Based on the generally higher vascular leakiness in malignant compared to benign tissue lesions, Spago Pix has the potential to significantly improve cancer diagnosis and characterization by MRI.

  7. Contrast-enhanced cardiovascular magnetic resonance in primary and ischemic dilated cardiomyopathy.

    Science.gov (United States)

    Calore, Chiara; Cacciavillani, Luisa; Boffa, Giovanni Maria; Silva, Caterina; Tiso, Enrico; Marra, Martina Perazzolo; Bacchiega, Enrico; Corbetti, Francesco; Iliceto, Sabino

    2007-10-01

    Differentiation between primary dilated cardiomyopathy and ischemic cardiomyopathy has an important clinical significance. Contrast-enhanced cardiovascular magnetic resonance can play a role in this task, identifying myocardial scarring or fibrosis as presence of delayed enhancement. The aim of the present study was to evaluate the diagnostic potential of contrast-enhanced cardiovascular magnetic resonance in differentiating dilated cardiomyopathy from ischemic cardiomyopathy. Contrast-enhanced cardiovascular magnetic resonance was performed in 100 patients with left ventricular dilatation and reduced systolic function: 24 had normal coronary arteries (dilated cardiomyopathy group) and 76 had significant coronary artery disease (ischemic cardiomyopathy group), with or without previous myocardial infarction. In the dilated cardiomyopathy group, only seven (29%) patients showed delayed enhancement and its pattern was characterized by mid-wall, patchy or diffuse location. All patients with ischemic cardiomyopathy and prior myocardial infarction (54 subjects) showed delayed enhancement with subendocardial (n = 4) or transmural (n = 50) extension. Among the 22 patients with ischemic cardiomyopathy but without previous myocardial infarction, 13 (59%) showed either subendocardial (n = 4) or transmural (n = 9) delayed enhancement. Patterns of delayed enhancement are different in dilated cardiomyopathy and ischemic cardiomyopathy, reflecting the presence of scarring or various degrees of fibrosis in left ventricular myocardium. The presence of subendocardial or transmural delayed enhancement at contrast-enhanced cardiovascular magnetic resonance allowed distinction between dilated cardiomyopathy and ischemic cardiomyopathy with high sensitivity (88%) and specificity (100%). Integration of cardiovascular magnetic resonance results with angiographic information can be useful in the identification of pathogenic mechanisms underlying left ventricular dysfunction.

  8. Intravenous contrast-enhanced cone beam computed tomography (IVCBCT of intrahepatic tumors and vessels

    Directory of Open Access Journals (Sweden)

    Cynthia L. Eccles, BSc

    2016-01-01

    Conclusions: Intravenous-CBCT may enhance the visibility of hepatic vessels and tumor in CBCT scans obtained during breath hold. Optimization of IV contrast timing and reduction of artifacts to improve tumor visualization warrant further investigation.

  9. Biliary complications following orthotopic liver transplantation: May contrast-enhanced MR Cholangiography provide additional information?

    Directory of Open Access Journals (Sweden)

    Piero Boraschi

    2016-01-01

    Conclusions: Contrast-enhanced T1-weighted MR Cholangiography may improve the level of diagnostic confidence provided by conventional T2-weighted MR Cholangiography in the evaluation of biliary complications after orthotopic liver transplantation.

  10. Contrast-enhanced ultrasonographic findings in three dogs with lung lobe torsion.

    Science.gov (United States)

    Caivano, Domenico; Birettoni, Francesco; Bufalari, Antonello; De Monte, Valentina; Angeli, Giovanni; Giorgi, Maria Elena; Patata, Valentina; Porciello, Francesco

    2016-03-01

    Lung lobe torsion is rare but life-threatening condition in the dog. Thoracic radiographs and conventional ultrasonography cannot be conclusive for the diagnosis, and computed tomography is useful but is limited by cost and availability. This report describes the findings of contrast-enhanced ultrasonography in 3 dogs with lung lobe torsion. Contrast-enhanced ultrasonography showed the absence or reduction of pulmonary vascularization secondary to twisting of the lung lobe around its bronchovascular pedicle in all three dogs. Moreover, contrast-enhanced ultrasonography distinguished partial pulmonary atelectasis from a lung lobe torsion. These preliminary results suggest that contrast-enhanced ultrasonography can improve the accuracy of conventional ultrasonography for detection of pulmonary blood flow compromise in dogs with lung lobe torsion.

  11. ''Occult'' post-contrast signal enhancement in pediatric diffuse intrinsic pontine glioma is the MRI marker of angiogenesis?

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Ashley E.; Reddick, Wilburn E.; Li, Yimei; Yuan, Ying; Glass, John O.; Baker, Justin N.; Kun, Larry E.; Broniscer, Alberto; Patay, Zoltan [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States)

    2014-05-15

    In diffuse intrinsic pontine gliomas (DIPG), subtracting pre-contrast from post-contrast T1-weighted images (T1WI) occasionally reveals subtle, ''occult'' enhancement. We hypothesized that this represents intravascular enhancement related to angiogenesis and hence that these tumors should have greater blood volume fractions than do non-enhancing tumors. We retrospectively screened MR images of 66 patients initially diagnosed with DIPG and analyzed pretreatment conventional and dynamic susceptibility contrast (DSC) perfusion MRI studies of 61 patients. To determine the incidence of occult enhancement, cerebral blood volume (CBV) values were compared in areas of occult enhancement (OcE), no enhancement (NE), and normal-appearing deep cerebellar white matter (DCWM). Tumors of 10 patients (16.4 %) had occult enhancement; those of 6 patients (9.8 %) had no enhancement at all. The average CBV in areas of occult enhancement was significantly higher than that in non-enhancing areas of the same tumor (P =.03), within DCWM in the same patient (P =.03), and when compared to anatomically paired/similar regions of interest (ROI) in patients with non-enhancing tumors (P =.005). Areas of OcE correspond to areas of higher CBV in DIPG, which may be an MRI marker for angiogenesis, but larger scale studies may be needed to determine its potential relevance to grading by imaging, treatment stratification, biopsy guidance, and evaluation of response to targeted therapy. (orig.)

  12. Diagnosis of subdural haematoma by computed axial tomography: use of xenon inhalation for contrast enhancement.

    Science.gov (United States)

    Zilkha, E; Kendall, B E; Loh, L; Hayward, R; Radue, E W; ingram, G S

    1978-01-01

    A subdural haematoma is described in which a definite computed tomographic (CT) scan diagnosis was made only after contrast enhancement had been achieved by the inhalation of xenon. The different types of enhancement obtained with iodide containing contrast media and with xenon are discussed. The use of xenon to obtain further information in conditions which are inadequately elucidated by conventional CT must be balanced against its anaesthetic effects and relatively high cost. Images PMID:650246

  13. The MRI Contrast Agent Gadoteridol Enhances Distribution of rAAV1 in the Rat Hippocampus

    OpenAIRE

    Hullinger, Rikki; Ugalde, Jeanet; Purón-Sierra, Liliana; Osting, Sue; Burger, Corinna

    2013-01-01

    Contrast agents are commonly used in combination with magnetic resonance imaging (MRI) to monitor the distribution of molecules in the brain. Recent experiments conducted in our laboratory have shown that co-infusion of recombinant Adeno-associated virus serotype 5 (rAAV5) and the MRI contrast agent gadoteridol (Gd) enhances vector transduction of in the rat striatum. The goal of this study was to determine whether gadoteridol may also be used as a tool to enhance transduction efficiency of r...

  14. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    Energy Technology Data Exchange (ETDEWEB)

    Pescatori, Lorenzo Carlo [Postgraduate School in Radiodiagnostics, University Studi di Milano, Milan (Italy); Sconfienza, Luca Maria; Mauri, Giovanni [Radiology Unit, Policlinico San Donato Research Hospital, Milan (Italy)

    2016-01-15

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic.

  15. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    Science.gov (United States)

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA

  16. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    NARCIS (Netherlands)

    G. Renaud (G.); J.G. Bosch (Hans); E.J.G. Sijbrands (Eric); V. Shamdasani (V.); R. Entrekin (R.); N. de Jong (Nico); A.F.W. van der Steen (Ton)

    2012-01-01

    textabstractMost techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be

  17. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Science.gov (United States)

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T.; Yupapin, Preecha P.

    2014-01-01

    Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection. PMID:24977191

  18. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Directory of Open Access Journals (Sweden)

    Hong-Seng Gan

    2014-01-01

    Full Text Available Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image’s maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher’s Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.

  19. Saltiness enhancement by taste contrast in bread prepared with encapsulated salt

    NARCIS (Netherlands)

    Noort, M.W.J.; Bult, J.H.F.; Stieger, M.

    2012-01-01

    In this study, we investigate a technological approach to reduce the sodium content of bread whilst retaining its sensory profile by creating taste contrast using encapsulated salt. We demonstrate that sensory contrast in bread induced by encapsulated salt can enhance saltiness and allows for a salt

  20. Modeling Dynamic Contrast-Enhanced MRI Data with a Constrained Local AIF

    DEFF Research Database (Denmark)

    Duan, Chong; Kallehauge, Jesper F.; Pérez-Torres, Carlos J

    2017-01-01

    PURPOSE: This study aims to develop a constrained local arterial input function (cL-AIF) to improve quantitative analysis of dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) data by accounting for the contrast-agent bolus amplitude error in the voxel-specific AIF. PROCEDURES...

  1. Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mehrabian, Hatef; Chandrana, Chaitanya; Pang, Ian; Chopra, Rajiv; Martel, Anne L. [University of Toronto, Department of Medical Biophysics, Sunnybrook Research Institute, Toronto, ON (Canada)

    2012-08-15

    Developing a method of separating intravascular contrast agent concentration to measure the arterial input function (AIF) in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of tumours, and validating its performance in phantom and in vivo experiments. A tissue-mimicking phantom was constructed to model leaky tumour vasculature and DCE-MR images of this phantom were acquired. An in vivo study was performed using tumour-bearing rabbits. Co-registered DCE-MRI and contrast-enhanced ultrasound (CEUS) images were acquired. An independent component analysis (ICA)-based method was developed to separate the intravascular component from DCE-MRI. Results were validated by comparing the time-intensity curves with the actual phantom and in vivo curves. Phantom study: the AIF extracted using ICA correlated well with the true intravascular curve. In vivo study: the AIFs extracted from DCE-MRI using ICA were very close to the true AIF. Intravascular component images were very similar to the CEUS images. The contrast onset times and initial wash-in slope of the ICA-derived AIF showed good agreement with the CEUS curves. ICA has the potential to separate the intravascular component from DCE-MRI. This could eliminate the requirement for contrast medium uptake measurements in a major artery and potentially result in more accurate pharmacokinetic parameters. (orig.)

  2. A new hardware-efficient algorithm and reconfigurable architecture for image contrast enhancement.

    Science.gov (United States)

    Huang, Shih-Chia; Chen, Wen-Chieh

    2014-10-01

    Contrast enhancement is crucial when generating high quality images for image processing applications, such as digital image or video photography, liquid crystal display processing, and medical image analysis. In order to achieve real-time performance for high-definition video applications, it is necessary to design efficient contrast enhancement hardware architecture to meet the needs of real-time processing. In this paper, we propose a novel hardware-oriented contrast enhancement algorithm which can be implemented effectively for hardware design. In order to be considered for hardware implementation, approximation techniques are proposed to reduce these complex computations during performance of the contrast enhancement algorithm. The proposed hardware-oriented contrast enhancement algorithm achieves good image quality by measuring the results of qualitative and quantitative analyzes. To decrease hardware cost and improve hardware utilization for real-time performance, a reduction in circuit area is proposed through use of parameter-controlled reconfigurable architecture. The experiment results show that the proposed hardware-oriented contrast enhancement algorithm can provide an average frame rate of 48.23 frames/s at high definition resolution 1920 × 1080.

  3. Mouse Rad1 deletion enhances susceptibility for skin tumor development

    Directory of Open Access Journals (Sweden)

    Wang Xiangyuan

    2010-03-01

    Full Text Available Abstract Background Cells are constantly exposed to stresses from cellular metabolites as well as environmental genotoxins. DNA damage caused by these genotoxins can be efficiently fixed by DNA repair in cooperation with cell cycle checkpoints. Unrepaired DNA lesions can lead to cell death, gene mutation and cancer. The Rad1 protein, evolutionarily conserved from yeast to humans, exists in cells as monomer as well as a component in the 9-1-1 protein complex. Rad1 plays crucial roles in DNA repair and cell cycle checkpoint control, but its contribution to carcinogenesis is unknown. Results To address this question, we constructed mice with a deletion of Mrad1. Matings between heterozygous Mrad1 mutant mice produced Mrad1+/+ and Mrad1+/- but no Mrad1-/- progeny, suggesting the Mrad1 null is embryonic lethal. Mrad1+/- mice demonstrated no overt abnormalities up to one and half years of age. DMBA-TPA combinational treatment was used to induce tumors on mouse skin. Tumors were larger, more numerous, and appeared earlier on the skin of Mrad1+/- mice compared to Mrad1+/+ animals. Keratinocytes isolated from Mrad1+/- mice had significantly more spontaneous DNA double strand breaks, proliferated slower and had slightly enhanced spontaneous apoptosis than Mrad1+/+ control cells. Conclusion These data suggest that Mrad1 is important for preventing tumor development, probably through maintaining genomic integrity. The effects of heterozygous deletion of Mrad1 on proliferation and apoptosis of keratinocytes is different from those resulted from Mrad9 heterozygous deletion (from our previous study, suggesting that Mrad1 also functions independent of Mrad9 besides its role in the Mrad9-Mrad1-Mhus1 complex in mouse cells.

  4. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest of the p......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...... contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery...

  5. Contrast-enhanced MR imaging of the endolymphatic sac in patients with sudden hearing loss

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine (Japan); Nakashima, Tsutomu [Department of Otolayngology, Nagoya University School of Medicine (Japan); Ichinose, Nobuyasu [Toshiba Nasu Operations, Tochigi (Japan)

    2002-05-01

    Our objective was to evaluate the frequency of contrast enhancement of the endolymphatic sac in patients with sudden hearing loss. Forty consecutive patients with sudden sensorineural hearing loss (20 males and 20 females; age range 11-82 years), 40 age-matched control subjects, and 5 patients with Meniere's disease were examined using the same imaging protocol on a 1.5-T MR system. Pre- and post-contrast-enhanced T1-weighted 3D spoiled gradient-echo sequence (3D SPGR; TR/TE=23/10 ms, no. of excitations=1, flip angle=30 ) images were obtained using a voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Contrast enhancement in the area of the endolymphatic sac was assessed by two radiologists, and the frequency of contrast enhancement was compared between the three study groups. Enhancement of the ipsilateral endolymphatic sac was observed in 30 of the 40 patients with sudden hearing loss (75%). Twenty of these 30 patients also showed enhancement on the contralateral side, and 1 patient showed enhancement only on the contralateral side. Only 1 of the 5 patients with Meniere's disease showed enhancement. Nine of the 40 control subjects (22.5%) showed enhancement (bilateral enhancement in 5 subjects, unilateral in 4). The frequency of enhancement in patients with sudden hearing loss was significantly higher than that in control subjects (P<0.0001) or patients with Meniere's disease (P<0.05). The frequency of contrast enhancement of the endolymphatic sac is significantly increased in patients with sudden hearing loss, but further study is necessary to clarify the relationship between this finding and the pathophysiology of sudden hearing loss. (orig.)

  6. Herpes simplex virus type 2 enhances HIV-1 susceptibility by affecting langerhans cell function

    NARCIS (Netherlands)

    M.A.W.P. de Jong (Marein); L. de Witte (Lot); M.E. Taylor (Maureen); T.B.H. Geijtenbeek (Teunis)

    2010-01-01

    textabstractGenital herpes is the most prevalent viral sexually transmitted infection worldwide and is mainly caused by HSV type 2 (HSV-2). HSV-2 infection enhances HIV-1 susceptibility, even in the absence of clinical symptoms. In this study, we investigated the effect of HSV-2 on HIV-1

  7. Indeterminate breast lesions: Can contrast enhanced digital mammography change our decisions?

    OpenAIRE

    Samira Saraya; Lamia Adel; Asmaa Mahmoud

    2017-01-01

    Objective: To assess the efficiency of dual energy contrast enhanced mammography in the assessment of the indeterminate breast lesions (BIRADS 3 and BIRADS 4). Materials and methods: 34 female having 39 indeterminate breast lesions (BIRADS 3 and BIRADS 4) by digital mammography were further examined by dual energy contrast enhanced mammography. Two images were acquired at low and high energy in MLO view after 2 min and in CC view at 4 min post iodinated contrast injection (1.5 ml/kg with f...

  8. Contrast-enhanced dual-energy mammography: a promising new imaging tool in breast cancer detection.

    Science.gov (United States)

    Lalji, Ulrich; Lobbes, Marc

    2014-05-01

    Contrast-enhanced dual-energy mammography (CEDM) is a promising new breast imaging tool for breast cancer detection. In CEDM, an iodine-based contrast agent is intravenously administered and subsequently, dual-energy mammography is performed. This results in a set of images containing both a regular mammogram and an image that contains contrast enhancement information. Preliminary studies have indicated that CEDM is superior to conventional mammography and might even match the diagnostic performance of breast MRI. In this review, the imaging technique, protocol and patient handling of CEDM is presented. Furthermore, an overview of current results on CEDM and potential future indications are outlined.

  9. Quantitative evaluation of contrast agent uptake in standard fat-suppressed dynamic contrast-enhanced MRI examinations of the breast.

    Science.gov (United States)

    Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A

    2018-01-01

    To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The proposed quantitative approach is practical, enabled the detection of differences between

  10. Diagnostic accuracy of semiautomatic lesion detection plus quantitative susceptibility mapping in the identification of new and enhancing multiple sclerosis lesions.

    Science.gov (United States)

    Zhang, Shun; Nguyen, Thanh D; Zhao, Yize; Gauthier, Susan A; Wang, Yi; Gupta, Ajay

    2018-01-01

    To evaluate the diagnostic accuracy of a novel non-contrast brain MRI method based on semiautomatic lesion detection using T2w FLAIR subtraction image, the statistical detection of change (SDC) algorithm (T2w + SDC), and quantitative susceptibility mapping (QSM). This method identifies new lesions and discriminates between enhancing and nonenhancing lesions in multiple sclerosis (MS). Thirty three MS patients who had MRIs at two different time points with at least one new Gd-enhancing lesion on the 2nd MRI were included in the study. For a reference standard, new lesions were identified by two neuroradiologists on T2w and post-Gd T1w images with the help of T2w + SDC. The diagnostic accuracy of the proposed method based on QSM and T2w + SDC lesion detection (T2w + SDC + QSM) for assessing lesion enhancement status was determined. Receiver operating characteristic (ROC) analysis was performed to compute the optimal lesion susceptibility cutoff value. A total of 165 new lesions (54 enhancing, 111 nonenhancing) were identified. The sensitivity and specificity of T2w + SDC + QSM in predicting lesion enhancement status were 90.7% and 85.6%, respectively. For lesions ≥50 mm 3 , ROC analysis showed an optimal QSM cutoff value of 13.5 ppb with a sensitivity of 88.4% and specificity of 88.6% (0.93, 95% CI, 0.87-0.99). For lesions ≥15 mm 3 , the optimal QSM cutoff was 15.4 ppb with a sensitivity of 77.9% and specificity of 94.0% (0.93, 95% CI, 0.89-0.97). The proposed T2w + SDC + QSM method is highly accurate for identifying and predicting the enhancement status of new MS lesions without the use of Gd injection.

  11. Feasibility of Left Ventricular Global Longitudinal Strain Measurements from Contrast-Enhanced Echocardiographic Images.

    Science.gov (United States)

    Medvedofsky, Diego; Lang, Roberto M; Kruse, Eric; Guile, Brittney; Weinert, Lynn; Ciszek, Boguslawa; Jacobson, Zachary; Negron, Jacqueline; Volpato, Valentina; Prado, Aldo; Patel, Amit R; Mor-Avi, Victor

    2017-11-23

    Although left ventricular global longitudinal strain (GLS) is an index of systolic function recommended by the guidelines, poor image quality may hamper strain measurements. While contrast agents are commonly used to improve endocardial visualization, no commercial speckle-tracking software is able to measure strain in contrast-enhanced images. This study aimed to test the accuracy of speckle-tracking software when applied to contrast-enhanced images in patients with suboptimal image quality. We studied patients with a wide range of GLS values who underwent transthoracic echocardiography. Protocol 1 included 44 patients whose images justified use of contrast but still allowed noncontrast speckle-tracking echocardiography (STE), which was judged as accurate and used as a reference. Protocol 2 included 20 patients with poor image quality that precluded noncontrast STE; cardiac magnetic resonance- (CMR-) derived strain was used as the reference instead. Half the manufacturer recommended dose of a commercial contrast agent (Definity/Optison/Lumason) was used to provide partial contrast enhancement. Higher than normal mechanical indices (0.6-0.7) and lowest frequency range for maximal penetration settings were used for imaging. GLS was measured (Epsilon) with and without contrast-enhanced images and by CMR-derived feature tracking (TomTec). Comparisons included linear regression and Bland-Altman analyses. The contrast STE analysis failed in 4/64 patients (6%). Manual corrections were needed to optimize tracking with contrast in all patients. GLS measurements were in good agreement between contrast and noncontrast images (r = 0.85; mean GLS in the contrast images, -12.9% ± 4.7%; bias, 0.34% ± 2.4%). Good agreement was also noted between contrast STE- and CMR-derived strain (r = 0.83; mean, GLS -13.5% ± 4.0%; bias, 0.72% ± 2.5%). We found that GLS measurements from contrast-enhanced images are feasible and accurate in most patients, even in those with poor

  12. Pelvic congestion syndrome initially detected by contrast enhanced F 18 FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Weung; Kim, Myoung Hyoung; Kim, Woo Hyoung; Kim, Chang Guhn [Wonkwang Univ. School of Medicine, Iksan (Korea, Republic of)

    2012-03-15

    Pelvic congestion syndrome (PCS) is said to occur as a result of retrograde flow in an incompetent ovarian vein. Ovarian vein incompetence is seen in approximately 10% of women, and up to 60% with this abnormality can develop PCS. The etiology of PCS is poorly understood and is likely to be multifactorial. Absence of ovarian vein valves is an important factor in its development. The causes of ovarian varicoceles are multifactorial, involving both mechanical and hormonal factors. Dilatation of the ovarian veins can result in vascular incompetence and retrograde blood flow. On either CT or magnetic resonance (MR) imaging studies, pelvic varices in PCS appear as dilated, tortuous, enhancing tubular structures near the ovaries and uterus. In addition, the extension of varices to the broad ligament and paravaginal venous plexus can be appreciated. With CT, the tubular nature of these structures and the pattern of enhancement after intravenous contrast medium administration distinguish them from lymphadenopathy or adnexal masses. Unlike such masses, pelvic varices appear isodense with other veins after contrast enhancement. Contrast enhanced CT data as part of the combined PET/CT examination provide additional information when compared with non enhanced PET/CT. Because CT data supply the anatomic background for PET, the most important benefit relates to more precise anatomic localization of pathology by differentiation of the lesion from its surrounding structures. By supporting lesion detection and characterization, CT contrast agents can be of additional value in F 18 FDG non avid disease. As in the presented case, careful review of CT images in contrast enhanced PET/CT enables the detection of F 18 FDG non avid disease such as PCS. As contrast enhanced F 18 FDG PET/CT had been performed frequently, being familiar with the findings of PCS on the contrast enhanced CT images would have been helpful for the nuclear medicine physicians.

  13. Usefulness of dynamic contrast enhanced lumbar spine MR imaging postoperative herniated lumbar disc

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Eun; Chung, Tae Sub; Kim, Young Soo; Cho, Yong Eun; Park, Mi Suk [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To compare the usefulness of dynamic contrast enhanced lumbar spine MR imaging with that of conventional delayed contrast enhanced MR imaging in the assessment of postoperative herniated lumbar disc. Forty-one postoperative herniated lumbar disc (HLD) lesions of 32 patients with back pain were examined with MR imaging (1.5T, Vision, Siemens, Germany). Five-phase dynamic 2D FLASH sagittal images (TR/TE = 118.1msec/4.1msec) were obtained every 19 seconds with a 4 minutes delayed image after contrast injection. As seen on delayed images, the discs were assessed as recurred, fibrosis, or no change. On dynamic images, the pattern of enhancement was evaluated as follows : Type 1 (no change in peripheral disc enhancement between the early and late phases) ; or Type 2 (minimal internal extension of marginal smooth enhancement during the late phase) ; or Type 3 (marked internal extension of peripheral irregular enhancement). Dynamic and delayed imaging were compared, and early epidural space enhancement with rapid wash-out was also evaluated. Of 41 postoperative HLDs, 39 lesions showed peripheral contrast enhancement. Evaluation depended on delayed imaging, and was as follows : recurred HLD (n=27) ; fibrosis (n=5) ; no change in postoperative disc (n=7). On dynamic contrast-enhanced imaging, enhancement patterns were Type 1 (n=29), Type 2 (n=7), and Type 3 (n=3). In 29 Type 1 lesions, there were no significant differences in image findings between dynamic and delayed images. However, in ten lesions (type 2 : n=7, type 3 : n=3), findings additional to those revealed by delayed images were demonstrated by dynamic contrast-enhanced MR imaging. Nine of the ten Type 2 and 3 lesions were diagnosed as recurred HLD. On dynamic images, five lesions showed early epidural space enhancement. Dynamic contrast-enhanced lumbar spine MR imaging provided additional findings such as increased peripheral disc enhancement, and epidural space enhancement, which cannot be detected on

  14. Contrast-enhanced ultrasound in ovarian tumors – diagnostic parameters: method presentation and initial experience

    Science.gov (United States)

    MAXIM, ANITA-ROXANA; BADEA, RADU; TAMAS, ATILLA; TRAILA, ALEXANDRU

    2013-01-01

    The aim of this paper is to discuss and illustrate the use of contrast-enhanced ultrasound in evaluating ovarian tumors compared to conventional ultrasound, Doppler ultrasound and the histopathological analysis and suggest how this technique may best be used to distinguish benign from malignant ovarian masses. We present the method and initial experience of our center by analyzing the parameters used in contrast-enhanced ultrasound in 6 patients with ovarian tumors of uncertain etiology. For examination we used a Siemens ultrasound machine with dedicated contrast software and the contrast agent SonoVue, Bracco. The patients underwent conventional ultrasound, Doppler ultrasound and i.v. administration of the contrast agent. The parameters studied were: inflow of contrast (rise time), time to peak enhancement, mean transit time. The series of patients is part of an extensive prospective PhD study aimed at elaborating a differential diagnosis protocol for benign versus malignant ovarian tumors, by validating specific parameters for contrast-enhanced ultrasound. Although the method is currently used with great success in gastroenterology, urology and senology, its validation in gynecology is still in the early phases. Taking into consideration that the method is minimally invasive and much less costly that CT/MRI imaging, demonstrating its utility in oncologic gynecology would be a big step in preoperative evaluation of these cases. PMID:26527912

  15. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Characterizing EPR-mediated passive drug targeting using contrast-enhanced functional ultrasound imaging

    NARCIS (Netherlands)

    Theek, B.; Gremse, F.; Kunjachan, S.; Fokong, S.; Pola, R.; Pechar, M.; Deckers, R.; Storm, Gerrit; Ehling, J.; Kiessling, F.; Lammers, Twan Gerardus Gertudis Maria

    2014-01-01

    The Enhanced Permeability and Retention (EPR) effect is extensively used in drug delivery research. Taking into account that EPR is a highly variable phenomenon, we have here set out to evaluate if contrast-enhanced functional ultrasound (ceUS) imaging can be employed to characterize EPR-mediated

  17. Management of Indeterminate Cystic Kidney Lesions: Review of Contrast-enhanced Ultrasound as a Diagnostic Tool.

    Science.gov (United States)

    Chang, Emily H; Chong, Wui K; Kasoji, Sandeep K; Dayton, Paul A; Rathmell, W Kimryn

    2016-01-01

    Indeterminate cystic kidney lesions found incidentally are an increasingly prevalent diagnostic challenge. Standard workup includes Bosniak classification with contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI). However, these tests are costly and not without risks. Contrast-enhanced ultrasound (CEUS) is a relatively new technique with lower risk of adverse events than iodine-containing contrast or gadolinium. In our review of the evidence for characterization of cystic kidney lesions with CEUS, CEUS displayed sensitivity (89%-100%) and negative predictive value (86%-100%) comparable to contrast-enhanced CT or MRI, with no decrease in specificity compared with CT and only a slight decrease compared with MRI. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Contrast-enhanced digital mammography (CEDM): phantom experiment and first clinical results

    Science.gov (United States)

    Marx, Christiane; Facius, Mirijam; Muller, Serge L.; Benali, Karim; Malich, Ansgar; Kaiser, Werner

    2002-05-01

    The introduction of the Full Field Digital Mammography (FFDM) opens the way to a large range of future advanced applications. Among them, Contrast Enhanced Digital Mammography (CEDM) could be a fast and less expensive alternative to Magnetic Resonance Imaging (MRI) for breast lesion characterization. In this work, we have investigated, first on phantom then on patients, the capability of a modified FFDM system to show the contrast enhancement of lesions after intra-venous injection of iodine. The uptake has been estimated from the difference between pre- and post-contrast images. Phantom results showed that 1) detectability thresholds of the contrast media were compatible with clinical conditions; 2) breast radiological thickness has a low impact on uptake detectability; 3) spatial and temporal analysis showed delayed margin contrast uptake of the simulated lesion and slow increase of contrast in the background. Preliminary results on patients have confirmed the phantom results and have shown a contrast uptake in all malignant lesions despite the observed patient motion artifacts, and some moderate signal variability. This study demonstrated the feasibility of the Contrast Enhanced Digital Mammography technique. Further investigations and clinical validations will have to be completed before it can be widely used in a daily routine practice.

  19. Characterization of D-maltose as a T2-exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-01-25

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  20. [Quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography].

    Science.gov (United States)

    Hauth, E A M; Jaeger, H; Maderwald, S; Mühler, A; Kimmig, R; Forsting, M

    2008-06-01

    The aim of the study was an evaluation of the quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography. In 137 patients, 183 contrast-enhanced lesions were identified in dynamic MR mammography. In 82 lesions histopathology was performed and in 101 lesions follow-up MR mammography was carried out. The contrast kinetics of lesions was analyzed quantitatively, on a pixel-by-pixel basis. The initial signal enhancement was coded by color intensity (bright, medium, dark), the post-initial signal enhancement was coded by color hue (blue, green, red). ROC analysis and logistic regression were performed. Malignant lesions showed a significantly higher number of bright red, medium red and dark red, bright green and medium green pixels than benign lesions. Benign lesions showed a significantly higher number of bright blue, medium blue and dark blue pixels than malignant lesions. The highest areas under the ROC curves (AUC) were found for medium red (AUC = 0.782) and medium green pixels (AUC = 0.733). A regression model with medium red and medium green pixels allows diagnosis of malignant lesions with a sensitivity of 60.7% and a specificity of 83.6%. The quantification of contrast-enhanced lesions allows objective analysis of the signal intensities in malignant and benign lesions. Therefore, this method might increase the specificity of MR mammography. Further developments are necessary before this method can be used for routine analysis of contrast-enhancing lesions in MR mammography.

  1. [Properties of gas (CO2) microbubbles made by hand agitation and it's contrast enhancing effect].

    Science.gov (United States)

    Matsuda, Y; Yabuuchi, I; Ito, T

    1998-04-01

    The property of gas (CO2) microbubbles made by hand agitation and it's contrast enhancing effect of abdominal organs on gray scale ultrasound are here described. The size of microbubbles of CO2 gas adequately prepared with 5% human serum albumin was nearly 23 microns in mean diameter. However, the size and the density of gas microbubbles are affected with many factors, including mixing times, volume ratio of gas and liquid and the species of gas and liquid. On the other hand, contrast enhancing effect is determined by the size and the density of gas microbubbles. For the adequate evaluation of contrast enhancing effect of abdominal tumors by enhanced ultrasonography, the property of gas microbubbles described as above should be carefully considered.

  2. Real-time contrast enhanced ultrasound imaging of focal splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Wei [Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou (China); Liu, GuangJian, E-mail: liugj@mail.sysu.edu.cn [Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou (China); Wang, Wei; Wang, Zhu; Huang, Yang; Xu, ZuoFeng; Xie, XiaoYan [Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou (China); Lu, MingDe [Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou (China); Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China)

    2014-04-15

    Objective: To investigate the imaging features of focal splenic lesions (FSLs) on contrast-enhanced ultrasound (CEUS). Methods: Thirty two patients with FSLs proved by pathology were retrospectively analyzed. CEUS was performed using intravenous bolus injection of 2.4 ml sulfur hexafluoride-filled microbubble contrast agent and real time scanning. There were hemangioma (n = 7), lymphoma (n = 8), true cyst (n = 3), infarction (n = 4), hematolymphangioma (n = 2), metastasis tumor (n = 2), and one for each of the following entities extramedullary hemopoiesis, hamartoma, tuberculosis, Langerhans’ cell histiocytosis, inflammatory pseudotumor and myxofibrosarcoma. Results: Among 21 benign lesions, 4 infarctions and 3 cysts presented non-enhancement throughout CEUS scanning, and the other 14 lesions displayed various enhancement levels with 6 (42.9%) hyper-enhancement, 2 (14.3%) iso-enhancement and 6 (42.9%) hypo-enhancement in arterial phase and 11 (78.6%) hypo-enhancement, 1 (7.1%) iso-enhancement and 2 (14.3%) hyper-enhancement in late phase, respectively. The enhancement pattern included 9 (64.3%) homogeneous, 4 (28.6%) heterogeneous and 1 (7.1%) rim-like enhancement. As for the malignant FSLs, all the lesions became completely or extensively hypo-enhancement during the late phase no matter their vascularity during arterial phase. Conclusions: The CEUS features reported in this series may enrich the knowledge for CEUS characterization of FSLs.

  3. Automatic determination of the arterial input function in dynamic susceptibility contrast MRI: comparison of different reproducible clustering algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Jiandong; Yang, Jiawen; Guo, Qiyong [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang (China)

    2015-05-01

    Arterial input function (AIF) plays an important role in the quantification of cerebral hemodynamics. The purpose of this study was to select the best reproducible clustering method for AIF detection by comparing three algorithms reported previously in terms of detection accuracy and computational complexity. First, three reproducible clustering methods, normalized cut (Ncut), hierarchy (HIER), and fast affine propagation (FastAP), were applied independently to simulated data which contained the true AIF. Next, a clinical verification was performed where 42 subjects participated in dynamic susceptibility contrast MRI (DSC-MRI) scanning. The manual AIF and AIFs based on the different algorithms were obtained. The performance of each algorithm was evaluated based on shape parameters of the estimated AIFs and the true or manual AIF. Moreover, the execution time of each algorithm was recorded to determine the algorithm that operated more rapidly in clinical practice. In terms of the detection accuracy, Ncut and HIER method produced similar AIF detection results, which were closer to the expected AIF and more accurate than those obtained using FastAP method; in terms of the computational efficiency, the Ncut method required the shortest execution time. Ncut clustering appears promising because it facilitates the automatic and robust determination of AIF with high accuracy and efficiency. (orig.)

  4. Contrast-Enhancement of the Anterior Eye Segment in Patients with Retinoblastoma: Correlation between Clinical, MR Imaging, and Histopathologic Findings

    NARCIS (Netherlands)

    de Graaf, P.; van der Valk, P.; Moll, A. C.; Imhof, S. M.; Schouten-van Meeteren, A. Y. N.; Knol, D. L.; Castelijns, J. A.

    2010-01-01

    BACKGROUND AND PURPOSE: AES contrast-enhancement is recognized in a substantial number of retinoblastoma-affected eyes. We retrospectively investigated the histopathologic basis of AES contrast-enhancement on MR images in retinoblastoma. MATERIALS AND METHODS: Pretreatment contrast-enhanced MR

  5. Diagnostic Value of Contrast-Enhanced Ultrasound Evaluation of Malignant and Benign Solitary Thyroid Nodules

    Directory of Open Access Journals (Sweden)

    Priedītis Pēteris

    2016-02-01

    Full Text Available The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign, underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule and type of TIC curve rs = 0.38 (p = 0.021, as well as between mode of contrast enhancement rs = 0.39 (p = 0.022 and wash-out pattern rs =0.39 (p = 0.024. The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.

  6. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    Science.gov (United States)

    Renaud, G.; Bosch, J. G.; ten Kate, G. L.; Shamdasani, V.; Entrekin, R.; de Jong, N.; van der Steen, A. F. W.

    2012-11-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.

  7. Attenuation Correction and Normalisation for Quantification of Contrast Enhancement in Ultrasound Images of Carotid Arteries.

    Science.gov (United States)

    Cheung, Wing Keung; Gujral, Dorothy M; Shah, Benoy N; Chahal, Navtej S; Bhattacharyya, Sanjeev; Cosgrove, David O; Eckersley, Robert J; Harrington, Kevin J; Senior, Roxy; Nutting, Christopher M; Tang, Meng-Xing

    2015-07-01

    An automated attenuation correction and normalisation algorithm was developed to improve the quantification of contrast enhancement in ultrasound images of carotid arteries. The algorithm first corrects attenuation artefact and normalises intensity within the contrast agent-filled lumen and then extends the correction and normalisation to regions beyond the lumen. The algorithm was first validated on phantoms consisting of contrast agent-filled vessels embedded in tissue-mimicking materials of known attenuation. It was subsequently applied to in vivo contrast-enhanced ultrasound (CEUS) images of human carotid arteries. Both in vitro and in vivo results indicated significant reduction in the shadowing artefact and improved homogeneity within the carotid lumens after the correction. The error in quantification of microbubble contrast enhancement caused by attenuation on phantoms was reduced from 55% to 5% on average. In conclusion, the proposed method exhibited great potential in reducing attenuation artefact and improving quantification in contrast-enhanced ultrasound of carotid arteries. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Contrast-enhanced Magnetic Resonance Imaging in Pediatric Patients: Review and Recommendations for Current Practice

    Directory of Open Access Journals (Sweden)

    Ravi Bhargava

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI, frequently with contrast enhancement, is the preferred imaging modality for many indications in children. Practice varies widely between centers, reflecting the rapid pace of change and the need for further research. Guideline changes, for example on contrast-medium choice, require continued practice reappraisal. This article reviews recent developments in pediatric contrast-enhanced MRI and offers recommendations on current best practice. Nine leading pediatric radiologists from internationally recognized radiology centers convened at a consensus meeting in Bordeaux, France, to discuss applications of contrast-enhanced MRI across a range of indications in children. Review of the literature indicated that few published data provide guidance on best practice in pediatric MRI. Discussion among the experts concluded that MRI is preferred over ionizing-radiation modalities for many indications, with advantages in safety and efficacy. Awareness of age-specific adaptations in MRI technique can optimize image quality. Gadolinium-based contrast media are recommended for enhancing imaging quality. The choice of most appropriate contrast medium should be based on criteria of safety, tolerability, and efficacy, characterized in age-specific clinical trials and personal experience.

  9. Digital contrast enhancement of (18)Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    The role of (18)fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold "m" and slope "e"). The input parameters which resulted in an image having a high value of 2(nd) order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters "m" had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope "e" was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted.

  10. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  11. Morphological image processing for quantitative shape analysis of biomedical structures: effective contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Kimori, Yoshitaka, E-mail: kimori@orion.ac.jp [National Institutes of Natural Sciences, 5-1 Higashiyama, Myodaiji, Okazaki, Aichi 444-8787 (Japan)

    2013-11-01

    A contrast enhancement approach utilizing a new type of mathematical morphology called rotational morphological processing is introduced. The method is quantitatively evaluated and then applied to some medical images. Image processing methods significantly contribute to visualization of images captured by biomedical modalities (such as mammography, X-ray computed tomography, magnetic resonance imaging, and light and electron microscopy). Quantitative interpretation of the deluge of complicated biomedical images, however, poses many research challenges, one of which is to enhance structural features that are scarcely perceptible to the human eye. This study introduces a contrast enhancement approach based on a new type of mathematical morphology called rotational morphological processing. The proposed method is applied to medical images for the enhancement of structural features. The effectiveness of the method is evaluated quantitatively by the contrast improvement ratio (CIR). The CIR of the proposed method is 12.1, versus 4.7 and 0.1 for two conventional contrast enhancement methods, clearly indicating the high contrasting capability of the method.

  12. The clinical significance of persistent trigeminal nerve contrast enhancement in patients who undergo repeat radiosurgery.

    Science.gov (United States)

    Mousavi, Seyed H; Akpinar, Berkcan; Niranjan, Ajay; Agarwal, Vikas; Cohen, Jonathan; Flickinger, John C; Kondziolka, Douglas; Lunsford, L Dade

    2017-07-01

    OBJECTIVE Contrast enhancement of the retrogasserian trigeminal nerve on MRI scans frequently develops after radiosurgical ablation for the management of medically refractory trigeminal neuralgia (TN). The authors sought to evaluate the clinical significance of this imaging finding in patients who underwent a second radiosurgical procedure for recurrent TN. METHODS During a 22-year period, 360 patients underwent Gamma Knife stereotactic radiosurgery (SRS) as their first surgical procedure for TN at the authors' center. The authors retrospectively analyzed the data from 59 patients (mean age 72 years, range 33-89 years) who underwent repeat SRS for recurrent pain at a median of 30 months (range 6-146 months) after the first SRS. The isocenter was 4 mm, and the median maximum doses for the first and second procedures were 80 Gy and 70 Gy, respectively. A neuroradiologist and a neurosurgeon blinded to the treated side evaluated the presence of nerve contrast enhancement on MRI series at the time of the repeat procedure. The authors correlated the presence of this imaging change with clinical outcomes. Pain outcomes and development of trigeminal sensory dysfunction were evaluated with the Barrow Neurological Institute (BNI) Pain Scale and BNI Numbness Scale, respectively. The mean length of follow-up after the second SRS was 58 months (95% CI 49-68 months). RESULTS At the time of the repeat SRS, contrast enhancement of the trigeminal nerve on MRI scans was observed in 31 patients (53%). Five years after the SRS, patients with this enhancement had lower actuarial rates of complete pain relief after the repeat SRS (27% [95% CI 7%-47%]) than patients without the enhancement (76% [95% CI 58%-94%]) (p < 0.001). At the 5-year follow-up, patients with the contrast enhancement also had a higher risk for trigeminal sensory loss after repeat SRS (75% [95% CI 59%-91%]) than patients without contrast enhancement (26% [95% CI 10%-42%]) (p = 0.001). Dysesthetic pain after repeat SRS

  13. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  14. Rapid bacterial antibiotic susceptibility test based on simple surface-enhanced Raman spectroscopic biomarkers

    Science.gov (United States)

    Liu, Chia-Ying; Han, Yin-Yi; Shih, Po-Han; Lian, Wei-Nan; Wang, Huai-Hsien; Lin, Chi-Hung; Hsueh, Po-Ren; Wang, Juen-Kai; Wang, Yuh-Lin

    2016-03-01

    Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploited for rapid AST and MIC determination of methicillin-susceptible S. aureus and wild-type E. coli as well as clinical isolates. The results obtained by this SERS-AST method were consistent with that by the standard incubation-based method, indicating its high potential to supplement or replace existing time-consuming methods and help mitigate the challenge of drug resistance in clinical microbiology.

  15. Human visual system-based image enhancement and logarithmic contrast measure.

    Science.gov (United States)

    Panetta, Karen A; Wharton, Eric J; Agaian, Sos S

    2008-02-01

    Varying scene illumination poses many challenging problems for machine vision systems. One such issue is developing global enhancement methods that work effectively across the varying illumination. In this paper, we introduce two novel image enhancement algorithms: edge-preserving contrast enhancement, which is able to better preserve edge details while enhancing contrast in images with varying illumination, and a novel multihistogram equalization method which utilizes the human visual system (HVS) to segment the image, allowing a fast and efficient correction of nonuniform illumination. We then extend this HVS-based multihistogram equalization approach to create a general enhancement method that can utilize any combination of enhancement algorithms for an improved performance. Additionally, we propose new quantitative measures of image enhancement, called the logarithmic Michelson contrast measure (AME) and the logarithmic AME by entropy. Many image enhancement methods require selection of operating parameters, which are typically chosen using subjective methods, but these new measures allow for automated selection. We present experimental results for these methods and make a comparison against other leading algorithms.

  16. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Sung-Min; Kim, Young-Whan; Han, Seong-Wook [University of Keimyung College of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of); Seo, Joon-Beom [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast enhanced multidetector-row computed tomography (MDCT). Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI.

  17. Contrast-enhanced dynamic MR imaging of postmolar gestational trophoblastic disease

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Y. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Torashima, M. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Takahashi, M. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Mizutani, H. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Miyazaki, K. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Matsuura, K. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Okamura, H. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan)

    1995-03-01

    Conventional spin-echo (SE) and contrast-enhanced dynamic MR imaging were performed on a 1.5 T superconductive unit for evaluation of myometrial lesions in postmolar gestational trophoblastic disease (GTD) in 10 women. MR imaging was done at the time of the initial examination (n=10), during (n=6), and after repeated courses of chemotherapy (n=10). The T2-weighted SE image revealed an enlarged uterus (n=7), disappearance of zonal anatomy (n=6), and heterogeneous signal intensities (n=8) with prominent flow voids (n=7). However, these abnormalities remained after repeated courses of chemotherapy, when the S-{beta}-HCG level returned to the normal range. Myometrial lesions characteristically had marked enhancement with areas of unenhancement on dynamic MR images in patients with highly elevated S-{beta}-HCG. Areas of contrast enhancement correlated with changes in S-{beta}-HCG level. The enhancement was reduced with decrease in S-{beta}-HCG level after repeated courses of chemotherapy. Six of 8 masses seen on T2-weighted images proved to be active trophoblastic lesions and 2 masses proved to be hematoma or necrosis. In 2 patients, abnormal myometrial lesions were detected only on contrast-enhanced dynamic MR imaging. These preliminary data indicate that contrast-enhanced dynamic MR imaging more clearly demonstrates myometrial involvement of postmolar GTD than conventional SE imaging. (orig.).

  18. Spleen evaluation using contrast enhanced ultrasonography and Doppler in dogs with subclinical ehrlichiosis

    Directory of Open Access Journals (Sweden)

    M.C. Maronezi

    2015-12-01

    Full Text Available The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, was used in microbubble contrast-enhanced ultrasonography to determine wash in, wash out and peak enhancement time in the splenic tissue. B-mode ultrasonography revealed splenomegaly with rounded borders, heterogeneous echotexture and mixed echogenicity. The vascular indices of the splenic artery were: systolic velocity of 22.59±8.07cm/s, diastolic velocity of 5.25±4.66cm/s and resistance index of 0.71±0.14; values not yet reported in Veterinary Medicine. Contrast-enhanced ultrasonography recorded wash in time of 5.31±0.7s, peak enhancement time of 18.56±2.90s and wash out time of 94.56±35.21s. The combination of conventional ultrasonography of the spleen and hemodynamic evaluation by Doppler and contrast-enhanced ultrasonography is important for the diagnosis of canine ehrlichiosis and could help monitor the clinical evolution of subclinical cases.

  19. Contrast enhanced ultrasound for the diagnosis of liver hemangiomas - results of a Romanian multicentre study

    DEFF Research Database (Denmark)

    Sirli, Roxana; Sporea, Ioan; Săndulescu, Daniela Larisa

    2015-01-01

    BACKGROUND AND AIM: Contrast enhanced ultrasound (CEUS) has been proven to be a reliable method for the characterization of focal liver lesions (FLL). The aim of this paper was to evaluate the performance of CEUS for the diagnosis of liver hemangiomas in a large cohort of patients. MATERIAL...... for hemangioma if a typical pattern was present following contrast (centripetal fill in during the arterial phase, hyperenhanced lesion during venous and late phases). In all cases a reference method was available (contrast CT or MRI or biopsy). The trial was registered in clinicaltrials.gov (Identifier NCT......01329458). RESULTS: During February 2011 - May 2015, 1153 CEUS examinations were performed for the evaluation of de novo FLL. Out of the 1153 de novo FLL, 238 cases were diagnosed as hemangiomas by CEUS (typical enhancing pattern). Contrast CT/MRI and biopsy diagnosed additional 24 hemangiomas. From...

  20. Predicting IDH mutation status of intrahepatic cholangiocarcinomas based on contrast-enhanced CT features.

    Science.gov (United States)

    Zhu, Yong; Chen, Jun; Kong, Weiwei; Mao, Liang; Kong, Wentao; Zhou, Qun; Zhou, Zhengyang; Zhu, Bin; Wang, Zhongqiu; He, Jian; Qiu, Yudong

    2018-01-01

    To explore the difference in contrast-enhanced computed tomography (CT) features of intrahepatic cholangiocarcinomas (ICCs) with different isocitrate dehydrogenase (IDH) mutation status. Clinicopathological and contrast-enhanced CT features of 78 patients with 78 ICCs were retrospectively analysed and compared based on IDH mutation status. There were 11 ICCs with IDH mutation (11/78, 14.1%) and 67 ICCs without IDH mutation (67/78, 85.9%). IDH-mutated ICCs showed intratumoral artery more often than IDH-wild ICCs (p = 0.023). Most ICCs with IDH mutation showed rim and internal enhancement (10/11, 90.9%), while ICCs without IDH mutation often appeared diffuse (26/67, 38.8%) or with no enhancement (4/67, 6.0%) in the arterial phase (p = 0.009). IDH-mutated ICCs showed significantly higher CT values, enhancement degrees and enhancement ratios in arterial and portal venous phases than IDH-wild ICCs (all p IDH mutation, with an area under the curve of 0.798 (p = 0.002). ICCs with and without IDH mutation differed significantly in arterial enhancement mode, and the tumour enhancement degree on multiphase contrast-enhanced CT was helpful in predicting IDH mutation status. • IDH mutation occurred frequently in ICCs. • ICCs with and without IDH mutation differed significantly in arterial enhancement mode. • ICCs with IDH mutation enhanced more than those without IDH mutation. • Enhancement ratio and tumour CT value can predict IDH mutation status.

  1. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  2. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    Science.gov (United States)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg‑1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  3. CT contrast enhancement following renal cryoablation – artefact or treatment failure?

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Andersen, Gratien

    Introduction and objective: Renal cryoablation is a valid treatment option for localized pT1a renal cancer. Treatment success is typically defined as absence of contrast enhancement (CE) and a decrease in size of the cryoablated renal mass (i.e. cryolesion) on follow-up imaging. We investigated...... (LCA) or percutaneous cryoablation (PCA) from August 2005 to August 2012 at Aarhus University Hospital. Six patients were excluded from analysis due to MRI follow-up. During routine postoperative CT follow-up, contrast enhancement of the cryolesion was identified in 34 of the 107 patients (32......, PADUA- score and level of contrast enhancement was significantly (penhancement pattern and number of cryoprobes used were not significantly different between the two groups. In patients where...

  4. The clinical use of contrast-enhanced ultrasound in the kidney.

    Science.gov (United States)

    Tenant, Sean C; Gutteridge, Catherine M

    2016-05-01

    Traditional B-Mode and Doppler sonography have been the stalwart of renal tract imaging for many years, and indeed, are in daily use in most centres as the modality of choice for the initial assessment of renal pathology. However, traditional ultrasound scanning can be limited in its ability to accurately characterise renal pathology, and can be inaccurate at determining benign from malignant lesions. Contrast-enhanced ultrasound conveys many benefits, being safe (especially in patients with renal dysfunction), does not require the use of ionising radiation, is quick and relatively cheap and can help to establish whether a focal renal lesion is sinister. Furthermore, it is our experience that contrast-enhanced ultrasound is not a difficult technique to master for the experienced ultrasound practitioner. In this article, we discuss the technique, interpretation and value of contrast-enhanced ultrasound in renal imaging, and describe how we use it in our practice.

  5. Role of Contrast-Enhanced Ultrasound in the Follow-up of Kidney Transplant Patients.

    Science.gov (United States)

    Korda, D; Deák, P Á; Kozma, V; Kiss, G; Doros, A

    2016-09-01

    Contrast-enhanced ultrasound combines the advantages of native ultrasound and other contrast-enhanced imaging modalities. In selected cases it can be preferable to computerized tomographic scan among kidney transplant recipients. We performed a retrospective study involving patients of Semmelweis University Department of Transplantation and Surgery who underwent contrast-enhanced ultrasound examination from 2011 to 2015. During this period, 251 examinations were performed, including 45 on kidney transplant patients. A Toshiba Aplio XU ultrasound device was used, and 1-1.5 mL contrast agent (Sonovue) was administered intravenously for each patient. The indications of these evaluations can be divided into 3 groups: characterization of circumscribed kidney lesions, control after radiofrequency ablation therapy, and examination of graft perfusion. Fully 93% of the examinations were conclusive. In the 1st group of the 37 cases where tumor-suspect lesions were investigated, 13 examinations suggested the presence of a space-occupying lesion. Of those 13 cases, 2 patients had a negative biopsy, nephrectomy was performed in 11 cases, and histologic evaluation verified a tumor in 8 samples. In the 2nd group, the ablation control examination detected a residual tumor in none of the 6 cases. Finally, in 1 of the 2 grafts where the circulation was investigated, blood flow was satisfactory, and in the other it was low. The contrast-enhanced ultrasound examination was conclusive in most cases. The applied contrast material is not nephrotoxic, and the method uses nonionizing radiation. These features make contrast-enhanced ultrasound highly suitable for the examination of kidney transplant patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Contrast-enhanced ultrsonography advanced and currrent status in abdominal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chung Yong Eun; Kim Ki Whang [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    n the field of contrast-enhanced ultrasonography (US), contrast agents are classified as either first- or second-generation agents depending on the gas within the microbubbles. In the case of first-generation contrast agents, a high-mechanical-index technique is used and only intermittent scanning is possible due to the early destruction of the microbubbles during the scanning. The use of second-generation contrast agents in a low-mechanical-index technique enables continuous scanning. Besides the detection and characterization of focal liver lesions, contrastenhanced US is helpful in the monitoring of radiofrequency ablation therapy and in the targeting step of an US-guided biopsy. Recently, there has been a demand for new criteria to evaluate the treatment response obtained using anti-angiogenic agents because morphologic criteria alone may not reflect the treatment response of the tumor and contrast-enhanced US can provide quantitative markers of tissue perfusion. In spite of the concerns related to its cost-effectiveness, contrast-enhanced US has the potential to be more widely used as a complimentary tool or to substitute the current imaging modalities in some occasions.

  7. Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis

    Science.gov (United States)

    Lau, Kristen C.; Lee, Hyo Min; Singh, Tanushriya; Maidment, Andrew D. A.

    2015-03-01

    Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. Temporal subtraction of the post-contrast DE images from the pre-contrast DE image is performed to analyze iodine uptake. Our previous work investigated image registration methods to correct for patient motion, enhancing the evaluation of vascular kinetics. In this project we investigate a segmentation algorithm which identifies blood vessels in the breast from our temporal DE subtraction images. Anisotropic diffusion filtering, Gabor filtering, and morphological filtering are used for the enhancement of vessel features. Vessel labeling methods are then used to distinguish vessel and background features successfully. Statistical and clinical evaluations of segmentation accuracy in DE-CBT images are ongoing.

  8. Multiresolution Local Contrast Enhancement of X-Ray Images for Poultry Meat Inspection

    Science.gov (United States)

    Chen, Zikuan; Tao, Yang; Chen, Xin

    2001-03-01

    A multiresolution-analysis-based local contrast transform is proposed to enhance local structures in x-ray images. The local contrast is defined as a ratio of the local intensity variation to the local mean. With wavelet multiresolution decomposition, the detail coefficients and approximation coefficients are interpreted, respectively, as local variations and local averages in virtue of the localization property of wavelet transform. Based on the local contrast transform, an algorithm is developed to modify coefficients before wavelet synthesis. An across-scale local contrast is obtained when the scale associated with the local variation is different from that of the local mean. The nonlinearity and local adaptiveness properties of local contrast transform result in structural enhancement in local dark regions in the reconstructed images. We applied this technique to deboned poultry inspection using x-ray images. Because of its high x-ray absorption, a foreign inclusion appears as a low-intensity object in an x-ray image, thus resulting in contrast enhancement in the reconstructed multiresolution images.

  9. Thermal enhancement of AFM phase contrast for imaging diblock copolymer thin film morphology.

    Science.gov (United States)

    Fasolk, M J; Mayes, A M; Magonov, N

    2001-11-01

    A simple and effective means of increasing the morphological detail in AFM phase micrographs of microphase separated block copolymer films is presented. Effective AFM phase imaging of microphase separated systems hinges upon the existence of appropriate contrast mechanisms such as differences in elasticity between the microphase separated domains. For some systems, AFM phase imaging at room temperature results in low contrast images due to a paucity of differential mechanical behavior between the microphase domains, e.g. at room temperature both species are glassy. Through the use of a heating apparatus custom-designed for AFM, an elastic contrast mechanism can be created in some systems by raising the specimen to a temperature between the glass transitions of the constituent polymer species. This serves to preferentially soften one species with respect to the other, thus enhancing the phase contrast mechanism, which results in micrographs with superior detail. This simple technique is demonstrated using films of a series of polystyrene-b-poly(n-alkyl methacrylate) diblock copolymers and both commercial and custom-built heating stages. By choosing appropriate measurement temperatures, AFM phase contrast could be greatly enhanced, or indeed created, when compared to room temperature images of these specimens. For these materials, contrast enhancement required that the sample be heated roughly 20 degrees C above the glass transition of the lower-Tg species.

  10. Contrast-enhanced ultrasonographic findings in three dogs with pancreatic insulinoma.

    Science.gov (United States)

    Nakamura, Kensuke; Lim, Sue-Yee; Ochiai, Kenji; Yamasaki, Masahiro; Ohta, Hiroshi; Morishita, Keitaro; Takagi, Satoshi; Takiguchi, Mitsuyoshi

    2015-01-01

    Abdominal ultrasonography is one of the most common diagnostic imaging modalities used for dogs with suspected insulinoma; however, pancreatic masses are clearly identified in fewer than half of affected dogs and benign pancreatic nodules can be difficult to differentiate from malignant ones. The purpose of this prospective study was to describe contrast-enhanced ultrasonography (CEUS) characteristics of confirmed pancreatic insulinoma in a group of dogs. Inclusion criteria were as follows: (1) repeated hypoglycemia (blood glucose levels ultrasonography; and (4) histological confirmation of pancreatic islet cell carcinoma. Immediately following conventional ultrasonography of the entire abdomen, CEUS of the pancreatic nodule and adjacent parenchyma was performed using contrast-specific technology pulse inversion imaging and perflubutane microbubble contrast agent. Three dogs met inclusion criteria. Pancreatic nodules in all the three dogs became more clearly demarcated after injection of the contrast agent. Each nodule showed different enhancement patterns: markedly hyperechoic for 5 s, slightly hyperechoic for 1 s, and clearly hypoechoic for over 30 s. These results were not in complete agreement with previously reported CEUS findings in human patients with insulinoma. All nodules were surgically resected and histopathologically confirmed as malignant insulinomas. Findings from the current study indicated that contrast-enhanced ultrasound may help to increase conspicuity of pancreatic insulinomas in dogs and that enhancement characteristics may be more variable in dogs than in humans. © 2014 American College of Veterinary Radiology.

  11. Biomedical photoacoustics beyond thermal expansion using triggered nanodroplet vaporization for contrast-enhanced imaging.

    Science.gov (United States)

    Wilson, Katheryne; Homan, Kimberly; Emelianov, Stanislav

    2012-01-10

    Since being discovered by Alexander Bell, photoacoustics may again be seeing major resurgence in biomedical imaging. Photoacoustics is a non-ionizing, functional imaging modality capable of high contrast images of optical absorption at depths significantly greater than traditional optical imaging techniques. Optical contrast agents have been used to extend photoacoustics to molecular imaging. Here we introduce an exogenous contrast agent that utilizes vaporization for photoacoustic signal generation, providing significantly higher signal amplitude than that from the traditionally used mechanism, thermal expansion. Our agent consists of liquid perfluorocarbon nanodroplets with encapsulated plasmonic nanoparticles, entitled photoacoustic nanodroplets. Upon pulsed laser irradiation, liquid perfluorocarbon undergoes a liquid-to-gas phase transition generating giant photoacoustic transients from these dwarf nanoparticles. Once triggered, the gaseous phase provides ultrasound contrast enhancement. We demonstrate in phantom and animal studies that photoacoustic nanodroplets act as dual-contrast agents for both photoacoustic and ultrasound imaging through optically triggered vaporization.

  12. Adrenal glands in hypovolemic shock: preservation of contrast enhancement at dynamic computed tomography.

    Science.gov (United States)

    Ito, Katsuyoshi; Higashi, Hiroki; Kanki, Akihiko; Tamada, Tsutomu; Yamashita, Takenori; Yamamoto, Akira; Watanabe, Shigeru

    2010-07-01

    To evaluate contrast enhancement effects of the adrenal glands at dynamic computed tomography (CT) in adult severe trauma patients with hypovolemic shock in comparison with patients without hypovolemic shock. This study population included a total of 74 patients with (n = 24) and without (n = 50) blunt trauma and hypovolemic shock. Measurement of CT attenuation values of the adrenal gland and calculation of the enhancement washout percentages were performed. The mean +/- SD CT attenuation values of the adrenal glands in the arterial phase of dynamic CT in patients with hypovolemic shock (137.3 +/- 41.7 Hounsfield unit [HU]) were not significantly different (P = 0.16) from those in control subjects (127.3 +/- 19.6 HU). The mean CT attenuation values of the adrenal glands in the delayed phase of dynamic CT in patients with hypovolemic shock (82.0 +/- 14.7 HU) were also not significantly different (P = 0.89) from those in control subjects (82.4 +/- 10.0 HU). The mean percentage (35%) of enhancement washout of the adrenal glands in patients with hypovolemic shock was not significantly different (P = 0.81) from that (34%) in control subjects. Contrast enhancement effects of the adrenal glands at contrast-enhanced dynamic CT in patients with hypovolemic shock were similar to those in control subjects, indicating the preserved enhancement and perfusion of the adrenal gland rather than intense and persistent enhancement in patients with hypovolemic shock.

  13. Application of contrast-enhanced ultrasound after liver transplantation: Current status and perspectives.

    Science.gov (United States)

    Ren, Jie; Wu, Tao; Zheng, Bo-Wen; Tan, Ying-Yi; Zheng, Rong-Qin; Chen, Gui-Hua

    2016-01-28

    Liver transplantation is an effective treatment for patients with end-stage liver disease. Accurate imaging evaluation of the transplanted patient is critical for ensuring that the limited donor liver is functioning appropriately. Ultrasound contrast agents (UCAs), in combination with contrast-specific imaging techniques, are increasingly accepted in clinical use for the assessment of the hepatic vasculature, bile ducts and liver parenchyma in pre-, intra- and post-transplant patients. We describe UCAs, their technical requirements, the recommended clinical indications, image interpretation and the limitations for contrast-enhanced ultrasound applications in liver transplantation.

  14. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  15. Contrast Enhancement on CT Following Renal Cryoablation – Does It Represent Treatment Failure?

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Andersen, Gratien

    Aim: Renal cryoablation is a valid treatment option for localized pT1a renal cancer. Treatment success is typically defined as absence of contrast enhancement (CE) on follow-up imaging. We investigate the development of lesions that demonstrate CE on follow-up CT after renal cryoablation. Materials...... not uncommon. As there are no clear-cut criteria for monitoring treatment failure, careful evaluation by an experienced radiologist and urologist is recommend. The significance of delayed contrast enhancement is not clearly evident and needs further investigation....

  16. Practical method and device for enhancing pulse contrast ratio for lasers and electron accelerators

    Science.gov (United States)

    Zhang, Shukui; Wilson, Guy

    2014-09-23

    An apparatus and method for enhancing pulse contrast ratios for drive lasers and electron accelerators. The invention comprises a mechanical dual-shutter system wherein the shutters are placed sequentially in series in a laser beam path. Each shutter of the dual shutter system has an individually operated trigger for opening and closing the shutter. As the triggers are operated individually, the delay between opening and closing first shutter and opening and closing the second shutter is variable providing for variable differential time windows and enhancement of pulse contrast ratio.

  17. Contrast-enhanced Digital Mammography: A Single-Institution Experience of the First 208 Cases.

    Science.gov (United States)

    Lewis, Tiffany C; Pizzitola, Victor J; Giurescu, Marina E; Eversman, William G; Lorans, Roxanne; Robinson, Kristin A; Patel, Bhavika K

    2017-01-01

    Contrast-enhanced digital mammography (CEDM) is the only imaging modality that provides both (a) a high-resolution, low-energy image comparable to that of digital mammography and (b) a contrast-enhanced image similar to that of magnetic resonance imaging. We report the initial 208 CEDM examinations performed for various clinical indications and provide illustrative case examples. Given its success in recent studies and our experience of CEDM primarily as a diagnostic adjunct, CEDM can potentially improve breast cancer detection by combining the low-cost conclusions of screening mammography with the high sensitivity of magnetic resonance imaging. © 2016 Wiley Periodicals, Inc.

  18. Chronologic Evaluation of Cerebral Hemodynamics by Dynamic Susceptibility Contrast Magnetic Resonance Imaging After Indirect Bypass Surgery for Moyamoya Disease.

    Science.gov (United States)

    Ishii, Yosuke; Tanaka, Yoji; Momose, Toshiya; Yamashina, Motoshige; Sato, Akihito; Wakabayashi, Shinichi; Maehara, Taketoshi; Nariai, Tadashi

    2017-12-01

    Although indirect bypass surgery is an effective treatment option for patients with ischemic-onset moyamoya disease (MMD), the time point after surgery at which the patient's hemodynamic status starts to improve and the time point at which the improvement reaches a maximum have not been known. The objective of the present study is to evaluate the hemodynamic status time course after indirect bypass surgery for MMD, using dynamic susceptibility contrast-magnetic resonance imaging (DSC-MRI). We retrospectively analyzed the cases of 25 patients with MMD (37 sides; mean age, 14.7 years; range, 3-36 years) who underwent indirect bypass surgery and repeated DSC-MRI measurement within 6 months after the operation. The difference in the mean transit time (MTT) between the target regions and the control region (cerebellum) was termed the MTT delay, and we measured the MTT delay's chronologic changes after surgery. The postoperative MTT delay was 1.81 ± 1.16 seconds within 1 week after surgery, 1.57 ± 1.01 at weeks 1-2, 1.55 ± 0.68 at weeks 2-4, 1.32 ± 0.68 at months 1-2, 0.95 ± 0.32 at months 2-3, and 0.77 ± 0.33 at months 3-6. Compared with the preoperative value (2.11 ± 0.98 seconds), the MTT delay decreased significantly from 2 to 4 weeks after surgery (P < 0.05). The amelioration of cerebral hemodynamics by indirect bypass surgery began soon after surgery and gradually reached a maximum at 3 months after surgery. DSC-MRI detected small changes in hemodynamic improvement, which are suspected to be caused by the initiation of angiogenesis and arteriogenesis in the early postoperative period. Copyright © 2017. Published by Elsevier Inc.

  19. Comparison of dynamic susceptibility contrast-MRI perfusion quantification methods in the presence of delay and dispersion

    Science.gov (United States)

    Maan, Bianca; Simões, Rita Lopes; Meijer, Frederick J. A.; Klaas Jan Renema, W.; Slump, Cornelis H.

    2011-03-01

    The perfusion of the brain is essential to maintain brain function. Stroke is an example of a decrease in blood flow and reduced perfusion. During ischemic stroke the blood flow to tissue is hampered due to a clot inside a vessel. To investigate the recovery of stroke patients, follow up studies are necessary. MRI is the preferred imaging modality for follow up because of the absence of radiation dose concerns, contrary to CT. Dynamic Susceptibility Contrast (DSC) MRI is an imaging technique used for measuring perfusion of the brain, however, is not standard applied in the clinical routine due to lack of immediate patient benefit. Several post processing algorithms are described in the literature to obtain cerebral blood flow (CBF). The quantification of CBF relies on the deconvolution of a tracer concentration-time curve in an arterial and a tissue voxel. There are several methods to obtain this deconvolution based on singular-value decomposition (SVD). This contribution describes a comparison between the different approaches as currently there is no best practice for (all) clinical relevant situations. We investigate the influence of tracer delay, dispersion and recirculation on the performance of the methods. In the presence of negative delays, the truncated SVD approach overestimates the CBF. Block-circulant and reformulated SVD are delay-independent. Due to its delay dependent behavior, the truncated SVD approach performs worse in the presence of dispersion as well. However all SVD approaches are dependent on the amount of dispersion. Moreover, we observe that the optimal truncation parameter varies when recirculation is added to noisy data, suggesting that, in practice, these methods are not immune to tracer recirculation. Finally, applying the methods to clinical data resulted in a large variability of the CBF estimates. Block-circulant SVD will work in all situations and is the method with the highest potential.

  20. Rapid antimicrobial susceptibility testing with electrokinetics enhanced biosensors for diagnosis of acute bacterial infections.

    Science.gov (United States)

    Liu, Tingting; Lu, Yi; Gau, Vincent; Liao, Joseph C; Wong, Pak Kin

    2014-11-01

    Rapid pathogen detection and antimicrobial susceptibility testing (AST) are required in diagnosis of acute bacterial infections to determine the appropriate antibiotic treatment. Molecular approaches for AST are often based on the detection of known antibiotic resistance genes. Phenotypic culture analysis requires several days from sample collection to result reporting. Toward rapid diagnosis of bacterial infection in non-traditional healthcare settings, we have developed a rapid AST approach that combines phenotypic culture of bacterial pathogens in physiological samples and electrochemical sensing of bacterial 16S rRNA. The assay determines the susceptibility of pathogens by detecting bacterial growth under various antibiotic conditions. AC electrokinetic fluid motion and Joule heating induced temperature elevation are optimized to enhance the sensor signal and minimize the matrix effect, which improve the overall sensitivity of the assay. The electrokinetics enhanced biosensor directly detects the bacterial pathogens in blood culture without prior purification. Rapid determination of the antibiotic resistance profile of Escherichia coli clinical isolates is demonstrated.

  1. Clinical usefulness of contrast-enhanced MP-RAGE of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Hauwe, L. van den [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Parizel, P.M. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Goethem, J.W. van [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Schepper, A.M.A. de [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium)

    1996-05-01

    Our purpose was to evaluate the usefulness of a 3D T1-weighted gradient-echo sequence (MP-RAGE) in clinical practice. We prospectively examined 200 patients with a variety of neurological disorders and symptoms. We compared lesion conspicuity and contrast enhancement on MP-RAGE images with conventional gadolinium-enhanced spin-echo (SE) T1-weighted images. Both the original MP-RAGE data and the reformatted images were characterised by improved differentiation between grey and white matter. More lesions were found on the 3D series, in both patients with neoplastic and non-neoplastic disease. Contrast enhancement of small oedematous lesions affecting the white matter in demyelinating disease was less obvious. Multiplanar reformatting, which can be realised in any desired plane and surface rendering with sophisticated segmentation algorithms superbly displayed the underlying anatomical relationships between lesions and normal brain structures. Excellent spatial resolution, the absence of posterior fossa artefacts and equivalent contrast enhancement resulted in an increased number of space-occupying lesions being found on the MP-RAGE images. Thus contrast-enhanced MP-RAGE is an alternative to conventional SE imaging in the investigation of intracranial masses. Although the total number of lesions found in patients with demyelinating disease was significantly higher on MP-RAGE, demonstration of blood-brain-barrier breakdown in active lesions was less obvious. (orig.). With 5 figs., 2 tabs.

  2. Use of computational fluid dynamics in the design of dynamic contrast enhanced imaging phantoms.

    Science.gov (United States)

    Hariharan, Prasanna; Freed, Melanie; Myers, Matthew R

    2013-09-21

    Phantoms for dynamic contrast enhanced (DCE) imaging modalities such as DCE computed tomography (DCE-CT) and DCE magnetic resonance imaging (DCE-MRI) are valuable tools for evaluating and comparing imaging systems. It is important for the contrast-agent distribution within the phantom to possess a time dependence that replicates a curve observed clinically, known as the 'tumor-enhancement curve'. It is also important for the concentration field within the lesion to be as uniform as possible. This study demonstrates how computational fluid dynamics (CFD) can be applied to achieve these goals within design constraints. The distribution of the contrast agent within the simulated phantoms was investigated in relation to the influence of three factors of the phantom design. First, the interaction between the inlets and the uniformity of the contrast agent within the phantom was modeled. Second, pumps were programmed using a variety of schemes and the resultant dynamic uptake curves were compared to tumor-enhancement curves obtained from clinical data. Third, the effectiveness of pulsing the inlet flow rate to produce faster equilibration of the contrast-agent distribution was quantified. The models employed a spherical lesion and design constraints (lesion diameter, inlet-tube size and orientation, contrast-agent flow rates and fluid properties) taken from a recently published DCE-MRI phantom study. For DCE-MRI in breast cancer detection, where the target tumor-enhancement curve varies on the scale of hundreds of seconds, optimizing the number of inlet tubes and their orientation was found to be adequate for attaining concentration uniformity and reproducing the target tumor-enhancement curve. For DCE-CT in liver tumor detection, where the tumor-enhancement curve varies on a scale of tens of seconds, the use of an iterated inlet condition (programmed into the pump) enabled the phantom to reproduce the target tumor-enhancement curve within a few per cent beyond about 6

  3. Fluoxetine Hydrochloride Enhances In Vitro Susceptibility to Chloroquine in Resistant Plasmodium falciparum

    Science.gov (United States)

    1992-12-01

    directed synthesis of new antimalarial drugs. Malaria is a significant source of morbidity in the world, ity, desipramine (3) and chlorpromazine (12... Hydrochloride Enhances In Vitro Susceptibility to Chloroguine in Resistant Plasmodium falciparum 4. AUTHOR(S) Lucia Gerena, Glenn T. Bass, Sr., Dennis E. Kyle...current description of the chloroquine resistance phenotype and may provide additional insights into lead-directed synthesis of new antimalarial drugs

  4. Comparison between survey radiography, B-mode ultrasonography, contrast-enhanced ultrasonography and contrast-enhanced multi-detector computed tomography findings in dogs with acute abdominal signs.

    Science.gov (United States)

    Shanaman, Miriam M; Schwarz, Tobias; Gal, Arnon; O'Brien, Robert T

    2013-01-01

    Contrast-enhanced multi-detector computed tomography (CE-MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast-enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B-mode ultrasound, CEUS, and CE-MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non-surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non-surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B-mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE-MDCT. Contrast-enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE-MDCT failed to identify. Accuracy for differentiation of surgical vs. non-surgical conditions was high for all modalities; 100%, 94%, and 94% for CE-MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE-MDCT is an accurate screening test for differentiating surgical from non-surgical acute abdominal conditions in dogs. Focused CEUS following CE-MDCT or B-mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions. © 2013 Veterinary Radiology & Ultrasound.

  5. Impact of model-based iterative reconstruction on image quality of contrast-enhanced neck CT.

    Science.gov (United States)

    Gaddikeri, S; Andre, J B; Benjert, J; Hippe, D S; Anzai, Y

    2015-02-01

    Improved image quality is clinically desired for contrast-enhanced CT of the neck. We compared 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction algorithms for the assessment of image quality of contrast-enhanced CT of the neck. Neck contrast-enhanced CT data from 64 consecutive patients were reconstructed retrospectively by using 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction. Objective image quality was assessed by comparing SNR, contrast-to-noise ratio, and background noise at levels 1 (mandible) and 2 (superior mediastinum). Two independent blinded readers subjectively graded the image quality on a scale of 1-5, (grade 5 = excellent image quality without artifacts and grade 1 = nondiagnostic image quality with significant artifacts). The percentage of agreement and disagreement between the 2 readers was assessed. Compared with 30% adaptive statistical iterative reconstruction, model-based iterative reconstruction significantly improved the SNR and contrast-to-noise ratio at levels 1 and 2. Model-based iterative reconstruction also decreased background noise at level 1 (P = .016), though there was no difference at level 2 (P = .61). Model-based iterative reconstruction was scored higher than 30% adaptive statistical iterative reconstruction by both reviewers at the nasopharynx (P iterative reconstruction. Model-based iterative reconstruction offers improved subjective and objective image quality as evidenced by a higher SNR and contrast-to-noise ratio and lower background noise within the same dataset for contrast-enhanced neck CT. Model-based iterative reconstruction has the potential to reduce the radiation dose while maintaining the image quality, with a minor downside being prominent artifacts related to thyroid shield use on model-based iterative reconstruction. © 2015 by American Journal of Neuroradiology.

  6. Use of contrast-enhanced ultrasonography in chronic pathologic canine testes

    OpenAIRE

    Volta, A.; Manfredi, S; Vignoli, M.; Russo, M.; England, G. C. W.; Rossi, F; Bigliardi, E.; Di Ianni, F.; Parmigiani, E; Bresciani, C.; Gnudi, G.

    2014-01-01

    Contrast-enhanced ultrasound with sulphur hexafluoride microbubbles was performed in seven healthy dogs without a history of reproductive pathology and with histologically confirmed normal testes and in 42 dogs with chronic scrotal anomalies. All dogs underwent orchiectomy and histological examination. Enhancement patterns and perfusion parameters (peak intensity and regional blood flow) of testes of healthy dogs and testes with chronic lesions were compared. Fourteen non-pathologic and 60 pa...

  7. Local gray level S-curve transformation - A generalized contrast enhancement technique for medical images.

    Science.gov (United States)

    Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Hani, Ahmad Fadzil M; Kumar, Dileep

    2017-04-01

    Most medical images suffer from inadequate contrast and brightness, which leads to blurred or weak edges (low contrast) between adjacent tissues resulting in poor segmentation and errors in classification of tissues. Thus, contrast enhancement to improve visual information is extremely important in the development of computational approaches for obtaining quantitative measurements from medical images. In this research, a contrast enhancement algorithm that applies gray-level S-curve transformation technique locally in medical images obtained from various modalities is investigated. The S-curve transformation is an extended gray level transformation technique that results into a curve similar to a sigmoid function through a pixel to pixel transformation. This curve essentially increases the difference between minimum and maximum gray values and the image gradient, locally thereby, strengthening edges between adjacent tissues. The performance of the proposed technique is determined by measuring several parameters namely, edge content (improvement in image gradient), enhancement measure (degree of contrast enhancement), absolute mean brightness error (luminance distortion caused by the enhancement), and feature similarity index measure (preservation of the original image features). Based on medical image datasets comprising 1937 images from various modalities such as ultrasound, mammograms, fluorescent images, fundus, X-ray radiographs and MR images, it is found that the local gray-level S-curve transformation outperforms existing techniques in terms of improved contrast and brightness, resulting in clear and strong edges between adjacent tissues. The proposed technique can be used as a preprocessing tool for effective segmentation and classification of tissue structures in medical images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Contrast-enhanced harmonic endoscopic ultrasound imaging: basic principles, present situation and future perspectives.

    Science.gov (United States)

    Alvarez-Sánchez, María-Victoria; Napoléon, Bertrand

    2014-11-14

    Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound (EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS (CH-EUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration (EUS-FNA) can not only render EUS more accurate but may also assist physicians in making decisions when EUS-FNA is inconclusive, increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity. The development of CH-EUS has also opened up exciting possibilities in other research areas, including monitoring responses to anticancer chemotherapy or to ethanol-induced pancreatic tissue ablation, anticancer therapies based on ultrasound-triggered drug and gene delivery, and therapeutic adjuvants by contrast ultrasound-induced apoptosis. Contrast harmonic imaging is gaining popularity because of its efficacy, simplicity and non-invasive nature, and many expectations are currently resting on this technique. If its potential is confirmed in the near future, contrast harmonic imaging will become a standard practice in EUS.

  9. Within-lesion differences in quantitative MRI parameters predict contrast enhancement in multiple sclerosis.

    Science.gov (United States)

    Jurcoane, Alina; Wagner, Marlies; Schmidt, Christoph; Mayer, Christoph; Gracien, Rene-Maxime; Hirschmann, Marc; Deichmann, Ralf; Volz, Steffen; Ziemann, Ulf; Hattingen, Elke

    2013-12-01

    To investigate the relationship between quantitative magnetic resonance imaging (qMRI) and contrast enhancement in multiple sclerosis (MS) lesions. We compared maps of T1 relaxation time, proton density (PD), and magnetization transfer ratio (MTR) between lesions with and without contrast enhancement as quantified by the amount of T1 shortening postcontrast agent (CA). In 17 patients with relapsing-remitting MS (RRMS), 15 with progressive MS (PMS), and 17 healthy controls, T1, PD, and MTR were measured at 3T and T1-mapping was repeated after CA administration. Manually drawn MS-lesions (3D-FLAIR) were labeled as enhancing if post-CA T1-shortening exceeded mean T1-shortening in normal-appearing white matter (NAWM) by at least 2 standard deviations. Precontrast T1, PD, and MTR were compared in enhancing lesions, nonenhancing lesions, NAWM, and gray matter. Precontrast T1, PD, and MTR differed significantly between enhancing and nonenhancing lesions in RRMS and PMS patients (all P T1 of gray matter differed significantly from RRMS and controls. Only MTR of gray matter differed between RRMS and controls. Contrast enhancement in MS quantified by relative T1 shortening may be predicted by precontrast abnormalities of T1, PD, and MTR and likely represents blood-brain barrier damage. Copyright © 2013 Wiley Periodicals, Inc.

  10. [Evaluation of imaging parameters for T1 dynamic contrast enhanced MRI with fast spin-echo].

    Science.gov (United States)

    Kanazawa, Yuuki; Miyati, Tosiaki; Inoue, Yusuke; Sato, Osamu

    2007-10-20

    For the purpose of continual measurement of the T1 value using the FSE (fast spin-echo) sequence and evaluation of the hemodynamics, we assessed T1 values when the imaging parameters were changed. Moreover, with the imaging parameters derived from this study, dynamic contrast-enhanced MR imaging (MRI) was examined in prostatic disease. First, the T1 value before contrast agent injection was measured with imaging parameters that had different TR and fixed TE. Next, dynamic contrast-enhanced imaging data were acquired for the imaging parameters using TE and TR in the same way as before contrast agent injection, and the T1 value of the tissue at contrast enhancement was measured. In the phantom studies, the TSE imaging parameters with short TE, long TR, and few ETL were connected with the mixed sequence. In dynamic study of the prostate, the difference between normal prostate and prostate cancer became clearer with the time-relaxation rate curve than the time-signal curve. This method using TSE is able to evaluate in greater detail information on hemodynamics and to perform dynamic study with the spin-echo sequence in extensive tissues.

  11. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith, E-mail: j.kooiman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Pasha, Sharif M., E-mail: s.m.pasha@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Zondag, Wendy, E-mail: w.zondag@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Sijpkens, Yvo W.J., E-mail: ysijpens@bronovo.nl [Department of Nephrology, Bronovo Hospital, The Hague (Netherlands); Molen, Aart J. van der, E-mail: molen@lumc.nl [Department of Radiology, LUMC, Leiden (Netherlands); Huisman, Menno V., E-mail: m.v.huisman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Dekkers, Olaf M., E-mail: o.m.dekkers@lumc.nl [Department of Clinical Epidemiology and Department of Endocrinology, LUMC, Leiden (Netherlands)

    2012-10-15

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted.

  12. Contrast-enhanced ultrasonography to assess blood perfusion of skeletal muscles in normal dogs.

    Science.gov (United States)

    Oh, Juyeon; Jeon, Sunghoon; Choi, Jihye

    2015-07-01

    This study evaluated perfusion of skeletal muscle using contrast enhanced ultrasonography in humerus, radius, femur and tibia in normal dogs. Contrast enhanced ultrasonography for each region was performed after injecting 0.5 mL and 1 mL of contrast medium (SonoVue) in every dog. Blood perfusion was assessed quantitatively by measuring the peak intensity, time to the peak intensity and area under the curve from the time-intensity curve. Vascularization in skeletal muscle was qualitatively graded with a score of 0-3 according to the number of vascular signals. A parabolic shape of time-intensity curve was observed from muscles in normal dogs, and time to the peak intensity, the peak intensity and area under the curve of each muscle were not significantly different according to the appendicular regions examined and the dosage of contrast agent administered. This study reports that feasibility of contrast enhanced ultrasonography for assessment of the muscular perfusion in canine appendicular regions.

  13. Technical aspects of contrast-enhanced magnetic resonance imaging of the breast: literature review; Aspectos tecnicos da ressonancia magnetica de mama com meio de contraste: revisao da literatura

    Energy Technology Data Exchange (ETDEWEB)

    Leopoldino, Denise de Deus; Gracio, Tatiana Schiller [Hospital Sao Luiz, Sao Paulo, SP (Brazil). Setor de Tomografia e Ressonancia Magnetica]. E-mail: leopoldinod@yahoo.com; D' Ippolito, Giuseppe; Bezerra, Alexandre Sergio de Araujo; Gracio, Tatiana Schiller [Hospital Sao Luiz, Sao Paulo, SP (Brazil). Setor de Diagnostico por Imagem

    2005-07-15

    With the advances in surface coil technology and the development of new imaging protocols in addition to the increase of the use of contrast agents, contrast enhanced magnetic resonance imaging (MRI) has emerged as a promising modality for detection, diagnosis and staging of breast cancer. Despite these advances, there are some unresolved issues, including no defined standard technique for contrast-enhanced breast MRI and no standard criteria of interpretation for the evaluation of such studies. In this article, we review the literature and discuss the general requirements and recommendations for contrast agent-enhanced breast MRI, including image interpretation criteria, MR equipment, dedicated radiofrequency coils, use of paramagnetic contrast agents, fat-suppression techniques, planes of acquisition, pulse sequence specifications and artifact sources. (author)

  14. Automatic hyperspectral camera for latent fingerprint detection and contrast enhancement. Final report, September 2, 1998 - March 17, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Paul Shnitser

    1999-06-01

    Physical Optics Corporation demonstrated the feasibility of the contrast enhancement of the latent fingerprint by portable hyperspectral imaging camera. The demonstrated non-contact technology is applicable for observation of the low contrast laser excited fluorescence from latent fingerprints as well as for the contrast enhancement of chemically processed fingerprints. Experiments were conducted with fingerprints on various types of substrates.

  15. Prediction of aortic enhancement on coronary CTA images using a test bolus of diluted contrast material.

    Science.gov (United States)

    Masuda, Takanori; Funama, Yoshinori; Imada, Naoyuki; Sato, Tomoyasu; Yamagami, Takuji; Tatsugami, Fuminari; Awai, Kazuo

    2014-12-01

    The purpose of our study was to compare test bolus techniques using undiluted or diluted contrast material for their ability to predict aortic enhancement on coronary computed tomographic angiography (c-CTA) images. We divided 200 consecutive patients who underwent c-CTA on a 64-MDCT scanner into two groups. In group A (n = 100), we used a test bolus of undiluted contrast material and in group B (n = 100), the contrast material was diluted. The injection volume was body weight × 0.2 (contrast material 100%) in group A and body weight × 0.7 (contrast material 30%, saline 70%) in group B. We then compared the CT number in the ascending aorta on c-CTA images obtained with undiluted and diluted contrast media to the CT number on c-CTA images. The mean CT number in the ascending aorta was significantly higher in group B than group A (217.1 vs. 157.4 HU, P images and on images acquired with the test bolus using undiluted or diluted test bolus (P enhancement before c-CTA scanning. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  16. Optimization of scantiming in abdominal breathhold contrast-enhanced MRA : an empirical guideline

    NARCIS (Netherlands)

    Boeve, WJ; Sluiter, WJ; Kamman, RL

    The objective of this study to determine a suitable scan timing scheme in contrast enhanced MRA for the depiction of the arterial. the portal and the systemic venous system in the abdomen with maximum signal intensity in healthy subjects and in patients with cirrhosis. The signal intensity in the

  17. Dynamic contrast-enhanced MRI for monitoring response to neoadjuvant chemotherapy in breast cancer

    NARCIS (Netherlands)

    Loo, C.E.

    2016-01-01

    The general aim of this thesis is to investigate the role of dynamic contrast-enhanced MRI in monitoring response of breast cancer during neoadjuvant chemotherapy. The role of MRI with respect to achieving personalized breast cancer treatment by improving response monitoring is examined. Our

  18. Contrast-enhanced duplex scanning of crural arteries by means of continuous infusion of Levovist

    NARCIS (Netherlands)

    Coffi, Stephen B.; Ubbink, Dirk Th; Zwiers, Ineke; van Gurp, Johan A. M.; Hanson, Dianne; Legemate, Dink A.

    2004-01-01

    Objectives: To estimate the dosage needed for continuous infusion and to investigate whether continuous infusion of the ultrasound contrast-enhancing agent Levovist (SH U 508A) can improve duplex scanning of crural arteries in patients with peripheral arterial obstructive disease (PAOD) eligible for

  19. Dual-energy contrast-enhanced digital mammography in routine clinical practice in 2013.

    Science.gov (United States)

    Badr, S; Laurent, N; Régis, C; Boulanger, L; Lemaille, S; Poncelet, E

    2014-03-01

    To date, analysis of the vascularisation of breast lesions mainly relies on MR imaging. However, the accessibility of MRI is sometimes limited and has led to the development of new means of imaging, such as dual-energy contrast-enhanced mammography, which provides data on the vascularisation of the breast along with the usual morphological information. The purpose of this paper is to present this new imaging technique as well as the recent references, illustrated by clinical reports derived from our everyday practice to focus on the advantages and disadvantages of this new breast exploration. Dual-energy contrast-enhanced mammography is a recent, seemingly promising technique, in the management of breast cancer. The main advantages consist of its easy installation, the good tolerance and the comfort in the interpretation of difficult to read mammograms. However, the indications and the role of dual-energy contrast-enhanced mammography still have to be determined within the diagnostic strategy of breast tumours. New studies are expected, especially to compare dual-energy contrast-enhanced mammography with breast MRI. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  20. A novel approach to tracer-kinetic modeling for (macromolecular) dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Jacobs, Igor; Strijkers, Gustav J.; Keizer, Henk M.; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias C.

    2016-01-01

    To develop a novel tracer-kinetic modeling approach for multi-agent dynamic contrast-enhanced MRI (DCE-MRI) that facilitates separate estimation of parameters characterizing blood flow and microvascular permeability within one individual. Monte Carlo simulations were performed to investigate the

  1. Infrared Contrast Enhancement Through Log-Power Histogram Modification

    NARCIS (Netherlands)

    Toet, A.; Wu, T.

    2015-01-01

    A simple power-logarithm histogram modification operator is proposed to enhance infrared (IR) image contrast. The algorithm combines a logarithm operator that smoothes the input image histogram while retaining the relative ordering of the original bins, with a power operator that restores the

  2. Contrast enhanced digital mammography: Is it useful in detecting lesions in edematous breast?

    Directory of Open Access Journals (Sweden)

    Noha Abd ElShafy ElSaid

    2015-09-01

    Conclusion: Dual-energy contrast-enhanced digital mammography is a useful technique in identification of lesions in mammographically dense edematous breasts and proved to be a useful tool in the follow-up of cases presenting by edema after conservative breast surgery and chemotherapy.

  3. [Value of real-time contrast-enhanced ultrasound in diagnosis of renal solid renal lesions].

    Science.gov (United States)

    Li, Xin; Liang, Ping; Yu, Xiaoling; Yu, Jie; Cheng, Zhigang; Han, Zhiyu; Liu, Fangyi; Mu, Mengjuan

    2014-06-01

    To investigate the value of real-time contrast-enhanced ultrasound (CEUS) in the diagnosis and differential diagnosis of renal solid renal lesions (RSLs). We retrospectively analyzed 140 cases of 152 RSLs with a mean diameter 3.1∓1.9 cm. CEUS was performed and the perfusion characteristics were analyzed using contrast pulse sequences (CPS) technique. CEUS findings were compared with biopsy histopathologic findings. A total of 137 malignant lesions (including 127 renal clear cell carcinomas, 8 renal papillary carcinomas and 2 chromophobe cell carcinomas) and 15 benign lesions (13 angiomyolipomas and 2 renal oncocytomas) were detected. Of the 137 malignant lesions, 98 (71.5%) showed contrast agent fast perfusion and hyper-enhancement or iso-enhancement in cortical phase, 104 (75.9%) showed hypo-enhancement in later corticalmedullary and late phase, and 125 (91.2%) showed rim-like enhancement. Tumors with a diameter ≤2 cm presented with homogeneous enhancement, and those ranging from 2 to 4 cm showed heterogeneous enhancement with a honeycomb feature; tumors greater than 4 cm featured heterogeneous enhancement with large no-enhancement necrotic areas. Of the benign lesions, 13 angiomyolipomas and 2 renal oncocytomas showed slow wash-in and slow wash-out mode. The diagnostic specificity, accuracy and positive predictive value of CEUS for RSLs were 94.9%, 96.1%, and 73.7%, as compared to 72.3%, 71.1%, and 19.1% with conventional US, respectively (Ppredictive value of CEUS were 93.3% and 99.2%, respectively, significantly higher than those of conventional US (60% and 94.3%, P=0.084, and 0.062, respectively). Real-time CEUS can provide valuable information for improving the diagnosis and differential diagnosis of RSLs.

  4. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  5. Nonlinear contrast enhancement in photoacoustic molecular imaging with gold nanosphere encapsulated nanoemulsions

    Science.gov (United States)

    Wei, Chen-wei; Lombardo, Michael; Larson-Smith, Kjersta; Pelivanov, Ivan; Perez, Camilo; Xia, Jinjun; Matula, Thomas; Pozzo, Danilo; O'Donnell, Matthew

    2014-01-01

    A composite contrast agent, a nanoemulsion bead with assembled gold nanospheres at the interface, is proposed to improve the specific contrast of photoacoustic molecular imaging. A phase transition in the bead's core is induced by absorption of a nanosecond laser pulse with a fairly low laser fluence (˜3.5 mJ/cm2), creating a transient microbubble through dramatically enhanced thermal expansion. This generates nonlinear photoacoustic signals with more than 10 times larger amplitude compared to that of a linear agent with the same optical absorption. By applying a differential scheme similar to ultrasound pulse inversion, more than 40 dB contrast enhancement is demonstrated with suppression of background signals.

  6. Nonlinear contrast enhancement in photoacoustic molecular imaging with gold nanosphere encapsulated nanoemulsions

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Chen-wei; Lombardo, Michael; Larson-Smith, Kjersta; Perez, Camilo; Xia, Jinjun; Matula, Thomas; Pozzo, Danilo; O' Donnell, Matthew [Departments of Bioengineering and Chemical Engineering, and Applied Physics Lab, University of Washington, Seattle, Washington 98195 (United States); Pelivanov, Ivan [Departments of Bioengineering and Chemical Engineering, and Applied Physics Lab, University of Washington, Seattle, Washington 98195 (United States); International Laser Center, Moscow State University, Moscow (Russian Federation)

    2014-01-20

    A composite contrast agent, a nanoemulsion bead with assembled gold nanospheres at the interface, is proposed to improve the specific contrast of photoacoustic molecular imaging. A phase transition in the bead's core is induced by absorption of a nanosecond laser pulse with a fairly low laser fluence (∼3.5 mJ/cm{sup 2}), creating a transient microbubble through dramatically enhanced thermal expansion. This generates nonlinear photoacoustic signals with more than 10 times larger amplitude compared to that of a linear agent with the same optical absorption. By applying a differential scheme similar to ultrasound pulse inversion, more than 40 dB contrast enhancement is demonstrated with suppression of background signals.

  7. Comparison of contrast-enhanced ultrasound and contrast-enhanced computed tomography in evaluating the treatment response to transcatheter arterial chemoembolization of hepatocellular carcinoma using modified RECIST

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Lin, Man-xia; Xu, Zuo-feng; Wang, Wei; Xie, Xiao-yan [Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); Sun Yat-Sen University, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Guangzhou (China); Lu, Ming-de; Kuang, Ming [Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China); Sun Yat-Sen University, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Guangzhou (China); Zheng, Ke-guo [Sun Yat-Sen University, Department of Radiology, Guangzhou (China); Zhuang, Wen-quan [Sun Yat-Sen University, Department of Interventional Radiology, Guangzhou (China)

    2015-08-15

    We aimed to compare contrast-enhanced ultrasound (CEUS) with contrast-enhanced computed tomography (CECT) for evaluating the treatment response to transcatheter arterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). Treatment responses of 130 patients who underwent TACE were evaluated by CEUS and CECT. We initially compared the abilities of CEUS and CECT to detect residual tumour, which were confirmed by histology or angiography. Then, we compared the tumour response to TACE assessed by CEUS and CECT, according to Modified Response Evaluation Criteria in Solid Tumours (mRECIST). The sensitivity and accuracy of detecting residual tumour by CEUS vs. CECT were 95.9 % vs. 76.2 % (p < 0.001) and 96.2 % vs. 77.7 % (p < 0.001), respectively. For target lesions, 13 patients were observed as complete response (CR) by CEUS, compared to 36 by CECT (p < 0.001). For nontarget lesions, 12 patients were observed as CR by CEUS, compared to 22 by CECT (p = 0.006). For overall response, eight patients were observed as CR by CEUS, compared to 31 by CECT (p < 0.001). The diagnostic performance of CEUS was superior to CECT for detecting residual tumour after TACE. In clinical, CEUS should be recommended as an optional procedure for assessing the tumour response to TACE. (orig.)

  8. Distal aortic intramural hematoma: clinical importance of focal contrast enhancement on CT images.

    Science.gov (United States)

    Park, Gyung-Min; Ahn, Jung-Min; Kim, Dae-Hee; Kang, Joon-Won; Song, Jong-Min; Kang, Duk-Hyun; Lim, Tae-Hwan; Song, Jae-Kwan

    2011-04-01

    To investigate the prevalence, fate, and effect of focal contrast enhancement lesion within the hematoma on contrast material-enhanced computed tomographic (CT) images in patients with distal aortic intramural hematoma (IMH). This retrospective study was approved by the institutional review board; informed consent was waived. Clinical and CT data in 107 patients with distal IMH who received medical treatment were analyzed, including remodeling processes of IMH at follow-up CT. IMH progression was defined as development of aortic dissection (AD) and aneurysm or hematoma increase. The frequency of focal contrast enhancement was 39.3%, and hematoma was thicker in patients with focal contrast enhancement than in those without (12.3 mm ± 3.6 [standard deviation] vs 10.1 mm ± 4.1, P = .006). Although development of AD occurred more frequently in patients with focal contrast enhancement (21% vs 3%, P = .006), hematoma resorption (57% vs 71%) was the most common pattern of remodeling in both groups without any significant difference (P = .148). The frequency of development of aortic aneurysm (17% vs 14%, P = .690) and increase of hematoma (0% vs 5%, P = .278) was not significantly different between groups. The 1-, 3-, 5-, and 7-year survival rates were 96.3% ± 1.8, 95.2% ± 2.1, 87.9% ± 3.4, and 80.7% ± 4.4, respectively. Patients with IMH progression showed lower survival rates than those without (P = .028). While no significant difference in the overall survival rates could be demonstrated in patients with and those without focal contrast enhancement (P = .442), our study had only 17% power to detect a difference of 10%. Initial maximal aortic diameter was the only factor associated with survival rates (hazard ratio = 1.129; 95% confidence interval: 1.063, 1.199). The optimal cutoff for prediction of mortality within 7 years was 41 mm. Urgent intervention for patients with focal contrast enhancement is not necessary during the acute stage, and long-term close

  9. Contrast-Enhanced Subharmonic and Harmonic Ultrasound of Renal Masses Undergoing Percutaneous Cryoablation.

    Science.gov (United States)

    Eisenbrey, John R; Shaw, Colette M; Lyshchik, Andrej; Machado, Priscilla; Lallas, Costas D; Trabulsi, Edouard J; Merton, Daniel A; Fox, Traci B; Liu, Ji-Bin; Brown, Daniel B; Forsberg, Flemming

    2015-07-01

    The objective of this study was to evaluate and compare contrast-enhanced subharmonic and harmonic ultrasound as tools for characterizing solid renal masses and monitoring their response to cryoablation therapy. Sixteen patients undergoing percutaneous ablation of a renal mass provided informed consent to undergo ultrasound examinations the morning before and approximately 4 months after cryoablation. Ultrasound contrast parameters during pretreatment imaging were compared to biopsy results obtained during ablation (n = 13). Posttreatment changes were evaluated by a radiologist and compared to contrast-enhanced magnetic resonance imaging (MRI)/computed tomography (CT) follow-up. All masses initially showed heterogeneous enhancement with both subharmonic and harmonic ultrasound. Early contrast washout in the mass relative to the cortex was observed in 6 of 9 malignant and 0 of 4 benign lesions in subharmonic mode and 8 of 9 malignant and 1 of 4 benign lesions in harmonic imaging. In cases where the lesion was adequately visualized at follow-up (n = 12), subharmonic and harmonic ultrasound showed accuracies of 83% and 75%, respectively, in predicting treatment outcome. Although harmonic imaging showed less overall error, no significant differences (P > .29) in ablation cavity volumes were observed between MRI/CT and either contrast-imaging mode. Subharmonic and harmonic contrast-enhanced ultrasound may be a safe and accurate imaging alternative for characterizing renal masses and evaluating their response to cryoablation therapy. Although subharmonic imaging was more accurate in detecting effective cryoablation, harmonic imaging was superior in quantifying ablation cavity volumes. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  10. Blunt splenic trauma: can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Becker, Christoph D; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-11-01

    To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48-72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  12. Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Kakite, Suguru, E-mail: sugkaki@med.tottori-u.ac.jp [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kurosaki, Masamichi [Department of Neurosurgery, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kanasaki, Yoshiko; Matsusue, Eiji; Kaminou, Toshio; Ogawa, Toshihide [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan)

    2011-07-15

    Introduction: To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0 Tesla (T). Methods: We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0 T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality. Results: At 3.0 T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts. Conclusion: Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0 T.

  13. Contrast-enhanced endoscopic ultrasound in discrimination between benign and malignant mediastinal and abdominal lymph nodes.

    Science.gov (United States)

    Hocke, Michael; Menges, Markus; Topalidis, Theodor; Dietrich, Christoph F; Stallmach, Andreas

    2008-04-01

    Enlarged lymph nodes in the mediastinum reflect neoplastic, infectious or other diseases. The classification of these nodes is crucial in the management of the patient. Currently, only invasive measures obtaining tissue samples reach satisfying specificity. Contrast-enhanced endoscopic ultrasound (EUS) may offer a non-invasive alternative. A total of 122 patients (age: 63 +/- 15 years, 92 males, 30 females) with enlarged mediastinal and/or paraaortic lymph nodes diagnosed by CT scan were included in the study. EUS-guided fine needle aspiration was performed and cytologic specimens were diagnosed as representing a malignant or benign process in case of Papanicolau IV and V, or Papanicolau I and II, respectively. Based on cytology results, the investigated lymph nodes were classified as neoplastic (n = 48) or non-neoplastic lymph nodes. Using the B-mode criteria the preliminary diagnosis was confirmed in 64 out of 74 benign lymph nodes (specificity 86%). Regarding malignant lymph nodes 33 of 48 were confirmed (sensitivity 68%). Using the advanced contrast-enhanced EUS criteria the diagnosis was confirmed in 68 of 74 benign lymph nodes (specificity 91%). However, in case of malignant lymph nodes the number of correct diagnoses dropped to 29 of 48 lymph nodes (sensitivity 60%). The contrast-enhanced EUS criteria to identify benign lymph nodes and node enlargement in malignant lymphoma do not differ. If those ten patients with malignant lymphoma are excluded, the sensitivity of the contrast enhanced EUS for malignant lymph nodes rises to 73%. Contrast-enhanced EUS improves the specificity in diagnosing benign lymph nodes as compared to B-mode EUS. It does not improve the correct identification of malignant lymph nodes and cannot replace EUS-guided fine-needle aspiration.

  14. Glioblastoma Presenting with Steroid-Induced Pseudoregression of Contrast Enhancement on Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Marcus D. Mazur

    2012-01-01

    Full Text Available Corticosteroid-induced reduction in contrast enhancement on radiographic imaging is most commonly associated with lymphoma but has been reported in other entities, including glioma. This finding may represent a diagnostic dilemma. Concern that steroid-induced cytotoxicity obscures histological diagnosis of suspected lymphoma may lead to postponement of a biopsy. If glioma is not considered in the differential diagnosis, reduction in tumor contrast enhancement may be misinterpreted as disease regression rather than a transient radiographic change. We report a case of a patient with an enhancing right temporoparietal mass adjacent to the atrium of the lateral ventricle. After treatment with dexamethasone was started, the mass exhibited marked reduction in contrast enhancement, with symptom improvement. The clinical course suggested lymphoma, and surgery was not performed. Subsequent screening for extra-axial lymphoma was negative. Two weeks later, the patient developed worsening symptoms, and repeat T1-weighted imaging showed interval increase in size and enhancement. The findings suggested a possible diagnosis of malignant glioma. The patient underwent a stereotactic-guided craniotomy for excision of the right temporoparietal mass lesion. Final histological diagnosis was glioblastoma multiforme, World Health Organization grade IV.

  15. EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS.

    Science.gov (United States)

    Rossi, Federica; Fina, Caroline; Stock, Emmelie; Vanderperren, Katrien; Duchateau, Luc; Saunders, Jimmy H

    2016-05-01

    Contrast-enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast-enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast-enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross-over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m(2) IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (dogs. Short-term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding. © 2016 American College of Veterinary Radiology.

  16. Delayed contrast enhancement on MR images of myocardium: past, present, future.

    Science.gov (United States)

    Ordovas, Karen G; Higgins, Charles B

    2011-11-01

    Differential enhancement of myocardial infarction was first recognized on computed tomographic (CT) images obtained with iodinated contrast material in the late 1970s. Gadolinium enhancement of myocardial infarction was initially reported for T1-weighted magnetic resonance (MR) imaging in 1984. The introduction of an inversion-recovery gradient-echo MR sequence for accentuation of the contrast between normal and necrotic myocardium was the impetus for widespread clinical use for demonstrating the extent of myocardial infarction. This sequence has been called delayed-enhancement MR and MR viability imaging. The physiologic basis for differential enhancement of myocardial necrosis is the greater distribution volume of injured myocardium compared with that of normal myocardium. It is now recognized that delayed enhancement occurs in both acute and chronic (scar) infarctions and in an array of other myocardial processes that cause myocardial necrosis, infiltration, or fibrosis. These include myocarditis, hypertrophic cardiomyopathy, amyloidosis, sarcoidosis, and other myocardial conditions. In several of these diseases, the presence and extent of delayed enhancement has prognostic implications. Future applications of delayed enhancement with development of MR imaging and CT techniques will be discussed. RSNA, 2011

  17. Contrast Agent-Enhanced Computed Tomography of Articular Cartilage: Association with Tissue Composition and Properties

    Energy Technology Data Exchange (ETDEWEB)

    Silvast, T.S.; Jurvelin, J.S.; Aula, A.S.; Lammi, M.J.; Toeyraes, J. (Dept. of Clinical Neurophysiology, Kuopio Univ. Hospital, Kuopio (Finland))

    2009-01-15

    Background: Contrast agent-enhanced computed tomography may enable the noninvasive quantification of glycosaminoglycan (GAG) content of articular cartilage. It has been reported that penetration of the negatively charged contrast agent ioxaglate (Hexabrix) increases significantly after enzymatic degradation of GAGs. However, it is not known whether spontaneous degradation of articular cartilage can be quantitatively detected with this technique. Purpose: To investigate the diagnostic potential of contrast agent-enhanced cartilage tomography (CECT) in quantification of GAG concentration in normal and spontaneously degenerated articular cartilage by means of clinical peripheral quantitative computed tomography (pQCT). Material and Methods: In this in vitro study, normal and spontaneously degenerated adult bovine cartilage (n=32) was used. Bovine patellar cartilage samples were immersed in 21 mM contrast agent (Hexabrix) solution for 24 hours at room temperature. After immersion, the samples were scanned with a clinical pQCT instrument. From pQCT images, the contrast agent concentration in superficial as well as in full-thickness cartilage was calculated. Histological and functional integrity of the samples was quantified with histochemical and mechanical reference measurements extracted from our earlier study. Results: Full diffusion of contrast agent into the deep cartilage was found to take over 8 hours. As compared to normal cartilage, a significant increase (11%, P<0.05) in contrast agent concentration was seen in the superficial layer of spontaneously degenerated samples. Significant negative correlations were revealed between the contrast agent concentration and the superficial or full-thickness GAG content of tissue (|R|>0.5, P<0.01). Further, pQCT could be used to measure the thickness of patellar cartilage. Conclusion: The present results suggest that CECT can be used to diagnose proteoglycan depletion in spontaneously degenerated articular cartilage with a

  18. Visualisation of contrast-enhanced intraoperative optical coherence tomography with indocyanine green.

    Science.gov (United States)

    Ehlers, Justis P; McNutt, Stephen; Dar, Suhail; Tao, Yuankai K; Srivastava, Sunil K

    2014-11-01

    Optical coherence tomography (OCT)-based visualisation of ophthalmic anatomy has transformed the clinical practice of ophthalmology. The translation of OCT into the surgical theatre is currently being actively researched and may provide a paradigm shift in surgical practice. Enhanced visualisation of tissues and tissue planes may provide further iterative improvement in surgeon feedback. Contrast-enhanced intraoperative OCT (iOCT) has been previously described with triamcinolone. In this report, we describe the OCT features and contrast enhancement noted with indocyanine green using iOCT in human subjects as well as an ex vivo analysis in porcine eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Design and validation of a mathematical breast phantom for contrast-enhanced digital mammography

    Science.gov (United States)

    Hill, Melissa L.; Mainprize, James G.; Jong, Roberta A.; Yaffe, Martin J.

    2011-03-01

    In contrast-enhanced digital mammography (CEDM) an iodinated contrast agent is employed to increase lesion contrast and to provide tissue functional information. Here, we present the details of a software phantom that can be used as a tool for the simulation of CEDM images, and compare the degree of anatomic noise present in images simulated using the phantom to that associated with breast parenchyma in clinical CEDM images. Such a phantom could be useful for multiparametric investigations including characterization of CEDM imaging performance and system optimization. The phantom has a realistic mammographic appearance based on a clustered lumpy background and models contrast agent uptake according to breast tissue physiology. Fifty unique phantoms were generated and used to simulate regions of interest (ROI) of pre-contrast images and logarithmically subtracted CEDM images using monoenergetic ray tracing. Power law exponents, β, were used as a measure of anatomic noise and were determined using a linear least-squares fit to log-log plots of the square of the modulus of radially averaged image power spectra versus spatial frequency. The power spectra for ROI selected from regions of normal parenchyma in 10 pairs of clinical CEDM pre-contrast and subtracted images were also measured for comparison with the simulated images. There was good agreement between the measured β in the simulated CEDM images and the clinical images. The values of β were consistently lower for the logarithmically subtracted CEDM images compared to the pre-contrast images, indicating that the subtraction process reduced anatomical noise.

  20. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Giesel, F.L., E-mail: f.giesel@dkfz.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Kratochwil, C., E-mail: Clemens.kratochwil@t-online.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Mehndiratta, A., E-mail: dramit.mehndiratta@gmail.com [Keble College, Institute of Biomedical Engineering, University of Oxford, Parks Road, Oxford OX13PG (United Kingdom); Wulfert, S., E-mail: sarah.wulfert@googlemail.com [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Moltz, J.H., E-mail: Jan.Moltz@mevis.fraunhofer.de [Fraunhofer MEVIS, Bremen (Germany); Zechmann, C.M., E-mail: christian.zechmann@med.uni-heidelberg.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Kauczor, H.U., E-mail: Hans-ulrich.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, INF 110, 69120 Heidelberg (Germany); Haberkorn, U., E-mail: uwe.haberkorn@med.uni-heidelberg.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Ley, S., E-mail: ley@gmx.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, INF 110, 69120 Heidelberg (Germany); Department of Medical Imaging, Toronto General Hospital (Canada)

    2012-10-15

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs.

  1. Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom.

    Science.gov (United States)

    Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco

    2013-11-01

    Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that

  2. Contrast enhancement of bite mark images using the grayscale mixer in ACR in Photoshop®.

    Science.gov (United States)

    Evans, Sam; Noorbhai, Suzanne; Lawson, Zoe; Stacey-Jones, Seren; Carabott, Romina

    2013-05-01

    Enhanced images may improve bite mark edge definition, assisting forensic analysis. Current contrast enhancement involves color extraction, viewing layered images by channel. A novel technique, producing a single enhanced image using the grayscale mix panel within Adobe Camera Raw®, has been developed and assessed here, allowing adjustments of multiple color channels simultaneously. Stage 1 measured RGB values in 72 versions of a color chart image; eight sliders in Photoshop® were adjusted at 25% intervals, all corresponding colors affected. Stage 2 used a bite mark image, and found only red, orange, and yellow sliders had discernable effects. Stage 3 assessed modality preference between color, grayscale, and enhanced images; on average, the 22 survey participants chose the enhanced image as better defined for nine out of 10 bite marks. The study has shown potential benefits for this new technique. However, further research is needed before use in the analysis of bite marks. © 2013 American Academy of Forensic Sciences.

  3. [Efficacy of gadobenate dimeglumine vs gadopentetate dimeglumine in contrast- enhanced magnetic resonance imaging for diagnosis of solitary brain metastases].

    Science.gov (United States)

    Wang, Qing-jun; Wang, Yong; Xu, Xian; Xiao, Hui; Ma, Lin

    2011-12-01

    To compare gadobenate dimeglumine (Gd-BOPTA) and gadopentetate dimeglumine (Gd-DTPA) for their efficacy as contrast agents in contrast-enhanced magnetic resonance imaging (MRI) for diagnosis of solitary brain metastases (SBM). We conducted an intra-individual study of contrast-enhanced T1-weighted MRI (T(1)WI) data from 27 Chinese patients with suspected SBM to compare the enhancement findings of two different MRI contrast agents, Gd-BOPTA and Gd-DTPA (at equivalent doses of 0.1 mmol/kg), for the detection of SBM. All the patients underwent two identical MRI examinations on a 3.0-T MRI scanner first with Gd-DTPA and then with Gd-BOPTA. Evaluation of the contrast enhancement was performed qualitatively (border delineation, extent, internal morphology, and contrast enhancement) and quantitatively (lesion-to-brain ratio, contrast-to-noise ratio, and percent enhancement) by 3 independent, fully blinded, and highly experienced neuroradiologists. Qualitative assessment by readers revealed a significant overall preference (P<0.05) for Gd-BOPTA over Gd-DOTA in terms of lesion border delineation, extent, lesion internal morphology, and contrast enhancement. Quantitative assessment also revealed a significant better performance of Gd-BOPTA in light of lesion-to-brain ratio (P<0.05), contrast-to-noise ratio (P<0.05), and percent enhancement (P<0.05). At an equivalent dose, Gd-BOPTA allows better contrast enhancement of SBM than Gd-DTPA in MRI.

  4. Autoimmune pancreatitis: imaging findings on contrast-enhanced MR, MRCP and dynamic secretin-enhanced MRCP.

    Science.gov (United States)

    Carbognin, G; Girardi, V; Biasiutti, C; Camera, L; Manfredi, R; Frulloni, L; Hermans, J J; Mucelli, R Pozzi

    2009-12-01

    This study retrospectively determined magnetic resonance (MR), MR cholangiopancreatography (MRCP) and secretin-MRCP findings in patients with autoimmune pancreatitis (AIP). The MR examinations of 28 patients with histopathologically proven AIP were reviewed. In 14 cases, secretin-enhanced MRCP was performed. The observers evaluated pancreatic parenchymal enlargement, signal intensity abnormalities, enhancement, vascular involvement, bile-duct diameter and main pancreatic duct (MPD) narrowing (diffuse/focal/segmental). After secretin administration, the presence of the "duct-penetrating" sign was evaluated. MR imaging showed diffuse pancreatic enlargement in 8/28(29%) cases, focal pancreatic enlargement in 16/28 (57%) cases and no enlargement in 4/28 (14%) cases. The alteration of pancreatic signal intensity was diffuse in 8/28 (29%) cases (eight diffuse AIP) and focal in 20/28 (71%) cases (20 focal AIP). Delayed pancreatic enhancement was present in all AIP, with peripheral rim of enhancement in 8/28 (29%) AIP (1/8 diffuse, 7/20 focal); vascular encasement was present in 7/28 (25%) AIP (1/8 diffuse, 6/20 focal); distal common bile duct narrowing was present in 12/28(43%) AIP (5/8 diffuse, 7/20 focal). MRCP showed MPD narrowing in 17/28 (61%) AIP (4/8 diffuse, 15/20 focal), MPD dilation in 8/28(29%) AIP (3/8 diffuse, 5/20 focal) and normal MPD in 1/8 diffuse AIP. Secretin-MRCP showed the duct-penetrating sign in 6/14(43%) AIP (one diffuse AIP with MPD segmental narrowing, five focal AIP with MPD focal narrowing), demonstrating integrity of the MPD. Delayed enhancement and MPD stenosis are suggestive for AIP on MR and MRCP imaging. Secretin-enhanced MRCP is a problem-solving tool in the differential diagnosis between focal AIP and ductal adenocarcinoma.

  5. Microarray Gene Expression Analysis of Murine Tumor Heterogeneity Defined by Dynamic Contrast-Enhanced MRI

    Directory of Open Access Journals (Sweden)

    Nick G. Costouros

    2002-07-01

    Full Text Available Current methods of studying angiogenesis are limited in their ability to serially evaluate in vivo function throughout a target tissue. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI and pharmacokinetic modeling provide a useful method for evaluating tissue vasculature based on contrast accumulation and washout. While it is often assumed that areas of high contrast enhancement and washout comprise areas of increased angiogenesis and tumor activity, the actual molecular pathways that are active in such areas are poorly understood. Using DCE-MRI in a murine subcutaneous tumor model, we were able to perform pharmacokinetic functional analysis of a tumor, coregistration of MRI images with histological cross-sections, immunohistochemistry, laser capture microdissection, and genetic profiling of tumor heterogeneity based on pharmacokinetic parameters. Using imaging as a template for biologic investigation, we have not found evidence of increased expression of proangiogenic modulators at the transcriptional level in either distinct pharmacokinetic region. Furthermore, these regions show no difference on histology and CD31 immunohistochemistry. However, the expression of ribosomal proteins was greatly increased in high enhancement and washout regions, implying increased protein translation and consequent increased cellular activity. Together, these findings point to the potential importance of posttranscriptional regulation in angiogenesis and the need for the development of angiogenesis-specific contrast agents to evaluate in vivo angiogenesis at a molecular level.

  6. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    Energy Technology Data Exchange (ETDEWEB)

    Looe, H.K.; Uphoff, Y.; Poppe, B. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy; Carl von Ossietzky Univ., Oldenburg (Germany). WG Medical Radiation Physics; Harder, D. [Georg August Univ., Goettingen (Germany). Medical Physics and Biophysics; Willborn, K.C. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy

    2012-02-15

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  7. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

    Science.gov (United States)

    Looe, H K; Uphoff, Y; Harder, D; Poppe, B; Willborn, K C

    2012-02-01

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice.

  8. Non-Infectious Peri-Electrode Edema and Contrast Enhancement Following Deep Brain Stimulation Surgery.

    Science.gov (United States)

    Arocho-Quinones, Elsa V; Pahapill, Peter A

    2016-12-01

    Dramatic radiographic abnormalities seen after electrode placement (DRAAEP) in deep brain stimulation (DBS) surgery is rare and it has not been associated with infection or hemorrhage. It has consisted of peri-electrode low-attenuation signals on CT scans and extensive T2-hyperintense signals without associated contrast enhancement (CE) on MRI scans. Report on the management of a patient with Parkinson's disease (PD) presenting with a seizure and findings of DRAAEP with positive CE 12 days after the placement of a subthalamic nucleus (STN) DBS electrode. Head CT and contrasted brain MRI scans were completed on presentation. Standard laboratory work up was obtained to evaluate for infection. Operative exploration deep to the burr-hole site surrounding the electrode was performed and cultures were obtained. Serial contrasted MRI scans were completed to determine the abnormal signal duration. A MRI revealed extensive T2-hyperintensity and positive CE concentrated around the burr-hole site surrounding the electrode. Intraoperative exploration revealed no evidence of infection and electrode revision was avoided. There was near resolution of the abnormal T2 signal and CE at six weeks from detection. The patient remained without signs of intracranial infection and responded well to DBS. To our knowledge, this is the first reported case of DRAAEP with positive gadolinium enhancement. Despite the extensive contrast enhancement, these DRAAEP appear to remain benign transient events that, in the absence of clinical signs of infection or neurologic decline, may warrant no further aggressive intervention such as hardware removal. © 2016 International Neuromodulation Society.

  9. A new combined technique for automatic contrast enhancement of digital images

    Directory of Open Access Journals (Sweden)

    Ismail A. Humied

    2012-03-01

    Full Text Available Some low contrast images have certain characteristics makes it difficult to use traditional methods to improve it. An example of these characteristics, that the amplitudes of images histogram components are very high at one location on the gray scale and very small in the rest of the gray scale. In the present paper, a new method is described. It can deal with such cases. The proposed method is a combination of Histogram Equalization (HE and Fast Gray-Level Grouping (FGLG. The basic procedure of this method is segments the original histogram of a low contrast image into two sub-histograms according to the location of the highest amplitude of the histogram components, and achieving contrast enhancement by equalizing the left segment of the histogram components using (HE technique and using (FGLG technique to equalize the right segment of this histogram components. The results have shown that the proposed method does not only produce better results than each individual contrast enhancement technique, but it is also fully automated. Moreover, it is applicable to a broad variety of images that satisfy the properties mentioned above and suffer from low contrast.

  10. Preliminary studies of enhanced contrast radiography in anatomy and embryology of insects with Elettra synchrotron light

    Science.gov (United States)

    Hönnicke, M. G.; Foerster, L. A.; Navarro-Silva, M. A.; Menk, R.-H.; Rigon, L.; Cusatis, C.

    2005-08-01

    Enhanced contrast X-ray imaging is achieved by exploiting the real part of the refraction index, which is responsible for the phase shifts, in addition to the imaginary part, which is responsible for the absorption. Such techniques are called X-ray phase contrast imaging. An analyzer-based X-ray phase contrast imaging set-up with Diffraction Enhanced Imaging processing (DEI) were used for preliminary studies in anatomy and embryology of insects. Parasitized stinkbug and moth eggs used as control agents of pests in vegetables and adult stinkbugs and mosquitoes ( Aedes aegypti) were used as samples. The experimental setup was mounted in the SYRMEP beamline at ELETTRA. Images were obtained using a high spatial resolution CCD detector (pixel size 14×14 μm 2) coupled with magnifying optics. Analyzer-based X-ray phase contrast images (PCI) and edge detection images show contrast and details not observed with conventional synchrotron radiography and open the possibility for future study in the embryonic development of insects.

  11. Preliminary studies of enhanced contrast radiography in anatomy and embryology of insects with Elettra synchrotron light

    Energy Technology Data Exchange (ETDEWEB)

    Hoennicke, M.G. [Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba-PR (Brazil)]. E-mail: marcelo@fisica.ufpr.br; Foerster, L.A. [Departamento de Zoologia, Universidade Federal do Parana, Caixa Postal 19020, 81531-990 Curitiba-PR (Brazil); Navarro-Silva, M.A. [Departamento de Zoologia, Universidade Federal do Parana, Caixa Postal 19020, 81531-990 Curitiba-PR (Brazil); Menk, R.-H. [Sincrotrone Trieste SCpA, Strada Statale S.S. 14 km 163.5, 34012 Basovizza, Trieste (Italy); Rigon, L. [Dipartamento di Fisica, Universita di Trieste, Via Valerio 2, 34100, Trieste Italy (Italy); Cusatis, C. [Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba-PR (Brazil)

    2005-08-11

    Enhanced contrast X-ray imaging is achieved by exploiting the real part of the refraction index, which is responsible for the phase shifts, in addition to the imaginary part, which is responsible for the absorption. Such techniques are called X-ray phase contrast imaging. An analyzer-based X-ray phase contrast imaging set-up with Diffraction Enhanced Imaging processing (DEI) were used for preliminary studies in anatomy and embryology of insects. Parasitized stinkbug and moth eggs used as control agents of pests in vegetables and adult stinkbugs and mosquitoes (Aedes aegypti) were used as samples. The experimental setup was mounted in the SYRMEP beamline at ELETTRA. Images were obtained using a high spatial resolution CCD detector (pixel size 14x14{mu}m{sup 2}) coupled with magnifying optics. Analyzer-based X-ray phase contrast images (PCI) and edge detection images show contrast and details not observed with conventional synchrotron radiography and open the possibility for future study in the embryonic development of insects.

  12. A wavelet-based spatially adaptive method for mammographic contrast enhancement.

    Science.gov (United States)

    Sakellaropoulos, P; Costaridou, L; Panayiotakis, G

    2003-03-21

    A method aimed at minimizing image noise while optimizing contrast of image features is presented. The method is generic and it is based on local modification of multiscale gradient magnitude values provided by the redundant dyadic wavelet transform. Denoising is accomplished by a spatially adaptive thresholding strategy, taking into account local signal and noise standard deviation. Noise standard deviation is estimated from the background of the mammogram. Contrast enhancement is accomplished by applying a local linear mapping operator on denoised wavelet magnitude values. The operator normalizes local gradient magnitude maxima to the global maximum of the first scale magnitude subimage. Coefficient mapping is controlled by a local gain limit parameter. The processed image is derived by reconstruction from the modified wavelet coefficients. The method is demonstrated with a simulated image with added Gaussian noise, while an initial quantitative performance evaluation using 22 images from the DDSM database was performed. Enhancement was applied globally to each mammogram, using the same local gain limit value. Quantitative contrast and noise metrics were used to evaluate the quality of processed image regions containing verified lesions. Results suggest that the method offers significantly improved performance over conventional and previously reported global wavelet contrast enhancement methods. The average contrast improvement, noise amplification and contrast-to-noise ratio improvement indices were measured as 9.04, 4.86 and 3.04, respectively. In addition, in a pilot preference study, the proposed method demonstrated the highest ranking, among the methods compared. The method was implemented in C++ and integrated into a medical image visualization tool.

  13. Contrast enhancement for portal images by combination of subtraction and reprojection processes for Compton scattering.

    Science.gov (United States)

    Hariu, Masatsugu; Suda, Yuhi; Chang, Weishan; Myojoyama, Atsushi; Saitoh, Hidetoshi

    2017-11-01

    For patient setup of the IGRT technique, various imaging systems are currently available. MV portal imaging is performed in identical geometry with the treatment beam so that the portal image provides accurate geometric information. However, MV imaging suffers from poor image contrast due to larger Compton scatter photons. In this work, an original image processing algorithm is proposed to improve and enhance the image contrast without increasing the imaging dose. Scatter estimation was performed in detail by MC simulation based on patient CT data. In the image processing, scatter photons were eliminated and then they were reprojected as primary photons on the assumption that Compton interaction did not take place. To improve the processing efficiency, the dose spread function within the EPID was investigated and implemented on the developed code. Portal images with and without the proposed image processing were evaluated by the image contrast profile. By the subtraction process, the image contrast was improved but the EPID signal was weakened because 15.2% of the signal was eliminated due to the contribution of scatter photons. Hence, these scatter photons were reprojected in the reprojection process. As a result, the tumor, bronchi, mediastinal space and ribs were observed more clearly than in the original image. It was clarified that image processing with the dose spread functions provides stronger contrast enhancement while maintaining a sufficient signal-to-noise ratio. This work shows the feasibility of improving and enhancing the contrast of portal images. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. A wavelet-based spatially adaptive method for mammographic contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Sakellaropoulos, P; Costaridou, L; Panayiotakis, G [Department of Medical Physics, School of Medicine, University of Patras, Patras 26500 (Greece)

    2003-03-21

    A method aimed at minimizing image noise while optimizing contrast of image features is presented. The method is generic and it is based on local modification of multiscale gradient magnitude values provided by the redundant dyadic wavelet transform. Denoising is accomplished by a spatially adaptive thresholding strategy, taking into account local signal and noise standard deviation. Noise standard deviation is estimated from the background of the mammogram. Contrast enhancement is accomplished by applying a local linear mapping operator on denoised wavelet magnitude values. The operator normalizes local gradient magnitude maxima to the global maximum of the first scale magnitude subimage. Coefficient mapping is controlled by a local gain limit parameter. The processed image is derived by reconstruction from the modified wavelet coefficients. The method is demonstrated with a simulated image with added Gaussian noise, while an initial quantitative performance evaluation using 22 images from the DDSM database was performed. Enhancement was applied globally to each mammogram, using the same local gain limit value. Quantitative contrast and noise metrics were used to evaluate the quality of processed image regions containing verified lesions. Results suggest that the method offers significantly improved performance over conventional and previously reported global wavelet contrast enhancement methods. The average contrast improvement, noise amplification and contrast-to-noise ratio improvement indices were measured as 9.04, 4.86 and 3.04, respectively. In addition, in a pilot preference study, the proposed method demonstrated the highest ranking, among the methods compared. The method was implemented in C++ and integrated into a medical image visualization tool.

  15. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  16. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  17. Fusion of contrast-enhanced breast MR and mammographic imaging data.

    Science.gov (United States)

    Behrenbruch, Christian P; Marias, Kostas; Armitage, Paul A; Yam, Margaret; Moore, Niall; English, Ruth E; Clarke, Jane; Brady, Michael

    2003-09-01

    Increasing use is being made of Gd-DTPA contrast-enhanced magnetic resonance imaging for breast cancer assessment since it provides 3D functional information via pharmacokinetic interaction between contrast agent and tumour vascularity, and because it is applicable to women of all ages as well as patients with post-operative scarring. Contrast-enhanced MRI (CE-MRI) is complementary to conventional X-ray mammography, since it is a relatively low-resolution functional counterpart of a comparatively high-resolution 2D structural representation. However, despite the additional information provided by MRI, mammography is still an extremely important diagnostic imaging modality, particularly for several common conditions such as ductal carcinoma in situ (DCIS) where it has been shown that there is a strong correlation between microcalcification clusters and malignancy. Pathological indicators such as calcifications and fine spiculations are not visible in CE-MRI and therefore there is clinical and diagnostic value in fusing the high-resolution structural information available from mammography with the functional data acquired from MRI imaging. This paper presents a novel data fusion technique whereby medial-lateral oblique (MLO) and cranial-caudal (CC) mammograms (2D data) are registered to 3D contrast-enhanced MRI volumes. We utilise a combination of pharmacokinetic modelling, projection geometry, wavelet-based landmark detection and thin-plate spline non-rigid 'warping' to transform the coordinates of regions of interest (ROIs) from the 2D mammograms to the spatial reference frame of the contrast-enhanced MRI volume. Of key importance is the use of a flexible wavelet-based feature extraction technique that enables feature correspondences to be robustly determined between the very different image characteristics of X-ray mammography and MRI. An evaluation of the fusion framework is demonstrated with a series of clinical cases and a total of 14 patient examples.

  18. Reduced expression IRF7 in nasal epithelial cells from smokers as a potential mechanism mediating enhanced susceptibility to influenza

    Science.gov (United States)

    Rationale: Smokers are more susceptible to viral infections, including influenza virus, yet the mechanisms mediating this effect are not known. Methods: We have established an in vitro model of differentiated nasal epithelial cells from smokers, which maintain enhanced levels...

  19. Degree of Enhancement on Contrast Enhanced Spectral Mammography (CESM) and Lesion Type on Mammography (MG): Comparison Based on Histological Results.

    Science.gov (United States)

    Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz

    2016-10-21

    BACKGROUND Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. MATERIAL AND METHODS The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. RESULTS Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). CONCLUSIONS Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions.

  20. Do children enhance phonetic contrasts in speech directed to a hearing-impaired peer?

    OpenAIRE

    Granlund, S.; Hazan, V. L.; Mahon, M.

    2015-01-01

    This study examines whether normal-hearing (NH) children enhance phonetic contrasts when speaking to a hearing-impaired (HI) peer. A problem-solving ‘Grid’ task was developed to elicit frequent repetitions of /p/-/b/, /s/-/S/ and /i/-/I/ segmental contrasts and point vowels in communicative spontaneous speech. Eighteen NH children between 9 and 15 years old performed the task once with a NH friend and once with a HI friend. Both category means and within-speaker variability were analysed. Res...

  1. Contrast Enhanced Ultrasound of the Kidneys: What Is It Capable of?

    Directory of Open Access Journals (Sweden)

    Demosthenes D. Cokkinos

    2013-01-01

    Full Text Available One of the many imaging uses of contrast enhanced ultrasound (CEUS is studying a wide variety of kidney pathology, due to its ability to detect microvascular blood flow in real time without affecting renal function. CEUS enables dynamic assessment and quantification of microvascularisation up to capillary perfusion. The objective of this paper is to briefly refresh basic knowledge of ultrasound (US contrast agents’ physical properties, to study technical details of CEUS scanning in the kidneys, and to review the commonest renal indications for CEUS, with imaging examples in comparison to baseline unenhanced US and computed tomography when performed. Safety matters and limitations of CEUS of the kidneys are also discussed.

  2. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  3. Temporal change of enhancement after gadolinium injection on contrast-enhanced CMR in reperfused acute myocardial infarction.

    Science.gov (United States)

    Matsumoto, Hidenari; Matsuda, Tetsuya; Miyamoto, Kenichi; Shimada, Toshihiko; Ushimaru, Shunpei; Mikuri, Mikiko; Yamazaki, Taketoshi

    2015-01-01

    A recent report demonstrated that early enhancement on contrast-enhanced cardiac magnetic resonance (CE-CMR) correlated with myocardial edema detected by T2-weighted CMR in reperfused acute myocardial infarction (AMI). However, the time at which the enhancement in salvaged myocardium disappears is yet to be determined. We aimed to examine the time course of the enhancement with the use of different quantification techniques and to compare the extent of enhancement with the myocardial edema. CE-CMR was performed at 2-20 min after gadolinium administration in 32 AMI patients. The extent of enhancement (% myocardium) was quantified by manual delineation and the threshold methods of 2-5 SDs above remote myocardium. In subendocardial infarct, the enhancement was greatest at 2 min regardless of the quantification techniques and decreased with time, particularly in the first 6 min. In transmural infarct, the change in the size of enhancement was modest although the time course of enhancement varied according to the quantification techniques. The sizes of enhancement were not significantly different between 15 and 20 min regardless of the techniques and infarct transmurality. The best agreement with myocardial edema was found at 2 min with average differences of 0.5% and -1.2% and limits of agreement of ±20.2% and ±21.2% for the manual and 2-SD techniques, respectively. The optimal timing for delineation of salvaged myocardium on CE-CMR is at 2min when the manual or 2-SD technique was employed. Imaging needs to be completed in a short time (ideally within a minute) because of rapid reduction of enhancement in salvaged myocardium. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  4. Contrast-enhanced digital holographic imaging of cellular structures by manipulating the intracellular refractive index.

    Science.gov (United States)

    Rommel, Christina E; Dierker, Christian; Schmidt, Lisa; Przibilla, Sabine; von Bally, Gert; Kemper, Björn; Schnekenburger, Jürgen

    2010-01-01

    The understanding of biological reactions and evaluation of the significance for living cells strongly depends on the ability to visualize and quantify these processes. Digital holographic microscopy (DHM) enables quantitative phase contrast imaging for high resolution and minimal invasive live cell analysis without the need of labeling or complex sample preparation. However, due to the rather homogeneous intracellular refractive index, the phase contrast of subcellular structures is limited and often low. We analyze the impact of the specific manipulation of the intracellular refractive index by microinjection on the DHM phase contrast. Glycerol is chosen as osmolyte, which combines high solubility in aqueous solutions and biological compatibility. We show that the intracellular injection of glycerol causes a contrast enhancement that can be explained by a decrease of the cytosolic refractive index due to a water influx. The underlying principle is proven by experiments inducing cell shrinkage and with fixated cells. The integrity of the cell membrane is considered as a prerequisite and allows a reversible cell swelling and shrinking within a certain limit. The presented approach to control the intracellular phase contrast demonstrated for the example of DHM opens prospects for applications with other quantitative phase contrast imaging methods.

  5. Ordered k-space acquisition in contrast enhanced magnetic resonance angiography (CE-MRA)

    Science.gov (United States)

    Wu, B.; Maclaren, J. R.; Millane, R. P.; Watts, R.; Bones, P. J.

    2008-03-01

    A new way of performing contrast enhanced magnetic resonance angiography (CE-MRA) is presented, in which the entire k-space is decomposed into interlaced subsets that are acquired sequentially. Based on a new parallel imaging technique, Generalized Unaliasing Incorporating object Support constraint and sensitivity Encoding (GUISE), reconstructions can be made using different subsets of k-space to reveal the level of contrast agent in the corresponding data acquisition time period. A proof-of-concept study using a custom made phantom was carried out to examine the utility of the new method. A quantity of contrast agent (copper sulfate solution) was injected into water flowing within a tube while data was acquired using an 8-coil receiver and the modified MRI sequence. A sequence of images was successfully reconstructed at high temporal resolution. This eliminated the need to precisely synchronize data acquisition with contrast arrival. Furthermore, subtraction of a pre-contrast data set prior to reconstruction, which eliminates the need for recovering the static background signal, has proven to be an effective way to improve the SNR and allow a higher temporal resolution to be achieved in recovering the dynamic signal containing contrast level change. Acceptably good reconstruction results were obtained at a temporal resolution equivalent to a 16-fold speed up compared to the time taken to fully sample k-space.

  6. MRT Letter: Contrast-Enhanced Computed Tomographic Imaging of Soft Callus Formation in Fracture Healing

    Science.gov (United States)

    Hayward, Lauren Nicole Miller; De Bakker, Chantal Marie-Jeanne; Lusic, Hrvoje; Gerstenfeld, Louis Charles; Grinstaff, Mark W.; Morgan, Elise Feng-I

    2012-01-01

    Formation of a cartilaginous soft callus at the site of a bone fracture is a pivotal stage in the healing process. Noninvasive, or even nondestructive, imaging of soft callus formation can be an important tool in experimental and pre-clinical studies of fracture repair. However, the low X-ray attenuation of cartilage renders the soft callus nearly invisible in radiographs. This study utilized a recently developed, cationic, iodinated contrast agent in conjunction with micro-computed tomography to identify cartilage in fracture calluses in the femora of C57BL/6J and C3H/HeJ mice. Fracture calluses were scanned beforeand after incubation in the contrast agent. The set of pre-incubation images was registered against and then subtracted from the set of post-incubation images, resulting in a three-dimensional map of the locations of cartilage in the callus, as labeled by the contrast agent. This map was then compared to histology from a previous study. The results showed that the locations where the contrast agent collected in relatively high concentrationswere similar to those of the cartilage. The contrast agent also identified a significant difference between the two strains of mice in the percentage of the callus occupied by cartilage, indicating that this method of contrast-enhanced computed tomography may be an effective technique for nondestructive, early evaluation of fracture healing. PMID:22038692

  7. MRT letter: Contrast-enhanced computed tomographic imaging of soft callus formation in fracture healing.

    Science.gov (United States)

    Hayward, Lauren Nicole Miller; de Bakker, Chantal Marie-Jeanne; Lusic, Hrvoje; Gerstenfeld, Louis Charles; Grinstaff, Mark W; Morgan, Elise Feng-I

    2012-01-01

    Formation of a cartilaginous soft callus at the site of a bone fracture is a pivotal stage in the healing process. Noninvasive, or even nondestructive, imaging of soft callus formation can be an important tool in experimental and pre-clinical studies of fracture repair. However, the low X-ray attenuation of cartilage renders the soft callus nearly invisible in radiographs. This study utilized a recently developed, cationic, iodinated contrast agent in conjunction with micro-computed tomography to identify cartilage in fracture calluses in the femora of C57BL/6J and C3H/HeJ mice. Fracture calluses were scanned before and after incubation in the contrast agent. The set of pre-incubation images was registered against and then subtracted from the set of post-incubation images, resulting in a three-dimensional map of the locations of cartilage in the callus, as labeled by the contrast agent. This map was then compared to histology from a previous study. The results showed that the locations where the contrast agent collected in relatively high concentrations were similar to those of the cartilage. The contrast agent also identified a significant difference between the two strains of mice in the percentage of the callus occupied by cartilage, indicating that this method of contrast-enhanced computed tomography may be an effective technique for nondestructive, early evaluation of fracture healing. Copyright © 2011 Wiley Periodicals, Inc.

  8. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Yun [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, The Catholic University of Korea (Korea, Republic of); Cha, Eun Suk [Department of Radiology, Ewha Womans University, School of Medicine, Mokdong Hospital (Korea, Republic of); Kim, Ji Youn [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Song, Byung Joo [Department of Surgery, Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  9. Reliability and responsiveness of dynamic contrast-enhanced magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Axelsen, M.B.; Poggenborg, R.P.; Stoltenberg, M.

    2013-01-01

    Objectives: To investigate the responsiveness to treatment and the reliability of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in rheumatoid arthritis (RA) knee joints. Methods: DCE-MRI was performed in 12 clinically active RA knee joints before and 1, 7, 30, and 180 days after...... intraarticular injection with 80 mg methylprednisolone. Using semi-automated image processing software, DCE-MRI parameters, including the initial rate of enhancement (IRE) and maximal enhancement (ME), were generated for three regions of interest (ROIs): ‘Whole slice’, ‘Quick ROI’, and ‘Precise ROI...... semi-automatic software is a reliable and responsive tool for assessing treatment in RA knees joints. Rough manual delineation of the joint to omit enhancement artefacts is necessary....

  10. Estimation of enhancement in third-order nonlinear susceptibility induced by a sharpening absorption band

    Science.gov (United States)

    Yoshimura, Tetsuzo

    1989-04-01

    We derived an empirical relationship between |χ (3)| and absorption spectra based on a simple two-level model. We calculated third-order nonlinear susceptibility for a methanol solution of rose bengal (RB), a polydiacetylene thin film (PDA), and a GaAlAs/ GaAs multiple quantum well (MQW) using the relationship. The estimated values are of the same order as the experimental ones. We also investigated the effect of the sharpening absorption bandwidth on |χ (3)| enhancement, and found that |χ (3)| of 10 -6 esu can be expected if the width of the PDA absorption band is reduced by one order of magnitude.

  11. Contrast-enhanced ultrasound in the diagnosis of gallbladder diseases: a multi-center experience.

    Directory of Open Access Journals (Sweden)

    Lin-Na Liu

    Full Text Available OBJECTIVE: To assess the usefulness of contrast-enhanced ultrasound (CEUS in differentiating malignant from benign gallbladder (GB diseases. METHODS: This study had institutional review board approval. 192 patients with GB diseases from 9 university hospitals were studied. After intravenous bonus injection of a phospholipid-stabilized shell microbubble contrast agent, lesions were scanned with low acoustic power CEUS. A multiple logistic regression analysis was performed to identify diagnostic clues from 17 independent variables that enabled differentiation between malignant and benign GB diseases. Receiver operating characteristic (ROC curve analysis was performed. RESULTS: Among the 17 independent variables, multiple logistic regression analysis showed that the following 4 independent variables were associated with the benign nature of the GB diseases, including the patient age, intralesional blood vessel depicted on CEUS, contrast washout time, and wall intactness depicted on CEUS (all P53.5 yrs is also a clue for GB malignancy.

  12. Contrast enhanced ultrasound cholangiography via T-tube following liver transplantation.

    Science.gov (United States)

    Chopra, Sascha S; Eisele, Robert; Stelter, Lars; Seehofer, Daniel; Grieser, Christian; Warnick, Peter; Denecke, Timm

    2012-12-31

    The objective was to evaluate contrast enhanced ultrasound (CEUS) based cholangiography compared to conventional radiography as a reference method in patients after liver transplantation. Contrast agents were administered through T-tubes, which were placed during the operation. Twelve patients with side-to-side choledocho-choledochostomy and standardized intraoperative T-tube placement were investigated on the 5th postoperative day (POD 5) with both techniques. All images were digitally acquired and assessed in consensus by two investigators regarding complete anatomic visualization, depiction of pathology (e.g. delayed contrast outflow, stenosis and leakage) and general image quality. CEUS cholangiography showed comparable results in the detection of biliary pathology and overall image quality. Regarding the visualization of the extrahepatic bile duct CEUS produced limited results in 6 patients. In conclusion, CEUS cholangiography via T-tube represents a potential bedside test for visualization of intrahepatic bile ducts of transplanted livers; its diagnostic value remains to be determined in further studies.

  13. Physiological assessment of contrast-enhancing frequency shaping and multiband compression in hearing aids.

    Science.gov (United States)

    Bruce, Ian C

    2004-08-01

    Spectral enhancement is now being used in many hearing aids in an attempt to compensate for broadened cochlear filtering. However, spectral enhancement may be counteracted by multiband-compression algorithms designed to compensate for the reduced dynamic range of the impaired cochlea. An alternative scheme for spectral enhancement, contrast-enhancing frequency shaping (CEFS), has been proposed, which results in an improved neural representation of the first and second formants of voiced speech segments in the impaired ear. In this paper, models of the normal and impaired ear are used to assess the compatibility of CEFS with multiband compression. Model auditory nerve responses were assessed under four conditions: (1) unmodified speech presented to a normal ear; (2) amplified, unshaped speech presented to an impaired ear; (3) CEFS speech presented to an impaired ear; and (4) CEFS+multiband-compression speech presented to an impaired ear. The results show that multiband compression does not reduce the benefits of CEFS, and in some cases multiband compression assists in preventing distortion of the neural representation of formants. These results indicate that the combination of contrast-enhancing frequency shaping and multiband compression should lead to improved perception of voiced speech segments in hearing aid users.

  14. The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

    Science.gov (United States)

    Tirman, Phillip J.; Chang, Yongmin; Ryeom, Hun-Kyu; Lee, Sang-Kwon; Kim, Yong-Sun; Kang, Duk-Sik

    2000-01-01

    Objective To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method. PMID:11752945

  15. Automatic Contrast Enhancement of Brain MR Images Using Hierarchical Correlation Histogram Analysis.

    Science.gov (United States)

    Chen, Chiao-Min; Chen, Chih-Cheng; Wu, Ming-Chi; Horng, Gwoboa; Wu, Hsien-Chu; Hsueh, Shih-Hua; Ho, His-Yun

    Parkinson's disease is a progressive neurodegenerative disorder that has a higher probability of occurrence in middle-aged and older adults than in the young. With the use of a computer-aided diagnosis (CAD) system, abnormal cell regions can be identified, and this identification can help medical personnel to evaluate the chance of disease. This study proposes a hierarchical correlation histogram analysis based on the grayscale distribution degree of pixel intensity by constructing a correlation histogram, that can improves the adaptive contrast enhancement for specific objects. The proposed method produces significant results during contrast enhancement preprocessing and facilitates subsequent CAD processes, thereby reducing recognition time and improving accuracy. The experimental results show that the proposed method is superior to existing methods by using two estimation image quantitative methods of PSNR and average gradient values. Furthermore, the edge information pertaining to specific cells can effectively increase the accuracy of the results.

  16. Contrast enhanced CT-scan to diagnose intrahepatic cholangiocarcinoma in patients with cirrhosis.

    Science.gov (United States)

    Iavarone, Massimo; Piscaglia, Fabio; Vavassori, Sara; Galassi, Marzia; Sangiovanni, Angelo; Venerandi, Laura; Forzenigo, Laura Virginia; Golfieri, Rita; Bolondi, Luigi; Colombo, Massimo

    2013-06-01

    Contrast enhanced computed tomography (CT-scan) is a standard of care for the radiological diagnosis of hepatocellular carcinoma (HCC) in patients with cirrhosis. This technique, however, is not validated to exclude intrahepatic cholangiocarcinoma (ICC) which may develop in patients with cirrhosis, as well. To assess the features of contrast CT-scan in the diagnosis of ICC, we reviewed all CT-scan films obtained in cirrhotic patients with a histologically documented ICC, taking in consideration the pattern and dynamics of the arterial, portal venous and delayed phases of contrast uptake. Thirty-two patients had 40 nodules of ICC (22 male; median age 62years; 13 hepatitis C) that were identified either during surveillance with abdominal ultrasound (21 patients, 66%) or incidentally (11 patients, 34%). ICC was either multifocal or ≥ 30 mm in 11 of the former and 10 of the latter group (52% vs. 91%, pCT-scan, while the remaining 38 showed a heterogeneous contrast enhancement pattern, being the arterial peripheral-rim enhancement present in 19 (50%) cases and a progressive homogeneous contrast uptake in 16 (42%) cases during the three vascular phases, with no relation to tumor size. Importantly, all nodules lacked the radiological hallmark of HCC, the only ICC nodule showing a homogeneous wash-in during the arterial phase followed by a wash-out in the delayed venous phase, however showing a homogeneous wash-in during the portal phase too. ICC in cirrhotic patients displays distinct vascular patterns at CT-scan that allow for differentiation from HCC. Copyright © 2013 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  17. Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans

    Science.gov (United States)

    Shahzad, Rahil; Bos, Daniel; Budde, Ricardo P. J.; Pellikaan, Karlijn; Niessen, Wiro J.; van der Lugt, Aad; van Walsum, Theo

    2017-05-01

    Early structural changes to the heart, including the chambers and the coronary arteries, provide important information on pre-clinical heart disease like cardiac failure. Currently, contrast-enhanced cardiac computed tomography angiography (CCTA) is the preferred modality for the visualization of the cardiac chambers and the coronaries. In clinical practice not every patient undergoes a CCTA scan; many patients receive only a non-contrast-enhanced calcium scoring CT scan (CTCS), which has less radiation dose and does not require the administration of contrast agent. Quantifying cardiac structures in such images is challenging, as they lack the contrast present in CCTA scans. Such quantification would however be relevant, as it enables population based studies with only a CTCS scan. The purpose of this work is therefore to investigate the feasibility of automatic segmentation and quantification of cardiac structures viz whole heart, left atrium, left ventricle, right atrium, right ventricle and aortic root from CTCS scans. A fully automatic multi-atlas-based segmentation approach is used to segment the cardiac structures. Results show that the segmentation overlap between the automatic method and that of the reference standard have a Dice similarity coefficient of 0.91 on average for the cardiac chambers. The mean surface-to-surface distance error over all the cardiac structures is 1.4+/- 1.7 mm. The automatically obtained cardiac chamber volumes using the CTCS scans have an excellent correlation when compared to the volumes in corresponding CCTA scans, a Pearson correlation coefficient (R) of 0.95 is obtained. Our fully automatic method enables large-scale assessment of cardiac structures on non-contrast-enhanced CT scans.

  18. Detection of bleeding in patients with major pelvic fractures: value of contrast-enhanced CT.

    Science.gov (United States)

    Cerva, D S; Mirvis, S E; Shanmuganathan, K; Kelly, I M; Pais, S O

    1996-01-01

    We performed a retrospective review of trauma patients who had undergone both pelvic angiography and preangiographic i.v. contrast-enhanced CT to determine whether CT can accurately demonstrate the presence or absence of pelvic bleeding in patients with multisystem trauma and major pelvic fractures. We reviewed the medical records and imaging studies of all patients, identified through a trauma radiology database, who had undergone pelvic angiography and preangiographic contrast-enhanced CT during a 48-month period. Results of CT scans were recorded by consensus interpretation of three radiologists without knowledge of angiographic findings. Sites of contrast material extravasation seen on CT scans were noted and compared with sites of bleeding or vascular injury identified by selective pelvic angiography. Thirty patients with blunt trauma and pelvic fractures underwent both pelvic angiography and preangiographic CT studies. Findings on pelvic angiograms were positive at 26 sites in 19 patients and included contrast agent extravasation at 23 sites and vessel abnormalities without extravasation at three sites. Preangiographic pelvic CT scans showed contrast agent extravasation at 20 sites in 16 patients. Three patients had no contrast agent extravasation demonstrated by CT but had bleeding demonstrated by angiography. CT detected bleeding in 16 of 19 patients who had extravasation or vascular injury demonstrated by angiography, for a sensitivity of 84%. Results of pelvic angiography were negative in 11 patients, and none had evidence of bleeding on preangiographic CT scans. Two sites of contrast agent extravasation identified in two patients by CT did not show bleeding at angiography, for a specificity of 85% for the detection of bleeding. The overall accuracy of CT for determining the presence or absence of bleeding was 90%. Knowledge of sites of ongoing hemorrhage is crucial for optimizing the sequence of diagnostic and therapeutic studies in patients with blunt

  19. Comparing the diagnostic accuracy of contrast-enhanced computed tomographic angiography and gadolinium-enhanced magnetic resonance angiography for the assessment of hemodynamically significant transplant renal artery stenosis.

    Science.gov (United States)

    Gaddikeri, Santhosh; Mitsumori, Lee; Vaidya, Sandeep; Hippe, Daniel S; Bhargava, Puneet; Dighe, Manjiri K

    2014-01-01

    To compare diagnostic accuracy of contrast-enhanced computed tomographic angiography (CTA) and gadolinium-enhanced magnetic resonance angiography (MRA) for the assessment of hemodynamically significant transplant renal artery stenosis (TRAS). After institutional review board approval, records of 27 patients with TRAS confirmed on digital subtraction angiography (DSA) were retrospectively reviewed. A total of 13 patients had MRA and 14 had CTA before DSA. Two board-certified fellowship-trained radiologists, one each from interventional radiology and body imaging blindly reviewed the DSA and CTA or MRA data, respectively. Sensitivity (SN), specificity (SP), positive predictive value, and negative predictive value of MRA and CTA were estimated using 50% stenosis as the detection threshold for significant TRAS. These parameters were compared between modalities using the Fisher exact test. Bias between MRA or CTA imaging and DSA was tested using the Wilcoxon signed-rank test. Two patients were excluded from the MRA group owing to susceptibility artifacts obscuring the TRAS. The correlation between MRA and DSA measurements of stenosis was r = 0.57 (95% CI:-0.02, 0.87; P = 0.052) and between CTA and DSA measurements was r = 0.63 (95% CI: 0.14, 0.87; P = 0.015); the difference between the 2 techniques was not significant (P = 0.7). Both imaging modalities tended to underestimate the degree of stenosis when compared with DSA. MRA group (SN and SP: 56% and 100%, respectively) and CTA group (SN and SP: 81% and 67%, respectively). There were no significant differences in detection performance between modalities (P>0.3 for all measures). We did not find that either modality had any advantage over the other in terms of measuring or detecting significant stenosis. Accordingly, MRA may be preferred over CTA after positive color Doppler ultrasound screening when not contraindicated owing to lack of ionizing radiation or nephrotoxic iodinated contrast. However, susceptibility of

  20. High susceptibility of Bt maize to aphids enhances the performance of parasitoids of lepidopteran pests.

    Directory of Open Access Journals (Sweden)

    Cristina A Faria

    Full Text Available Concerns about possible undesired environmental effects of transgenic crops have prompted numerous evaluations of such crops. So-called Bt crops receive particular attention because they carry bacteria-derived genes coding for insecticidal proteins that might negatively affect non-target arthropods. Here we show a remarkable positive effect of Bt maize on the performance of the corn leaf aphid Rhopalosiphum maidis, which in turn enhanced the performance of parasitic wasps that feed on aphid honeydew. Within five out of six pairs that were evaluated, transgenic maize lines were significantly more susceptible to aphids than their near-isogenic equivalents, with the remaining pair being equally susceptible. The aphids feed from the phloem sieve element content and analyses of this sap in selected maize lines revealed marginally, but significantly higher amino acid levels in Bt maize, which might partially explain the observed increased aphid performance. Larger colony densities of aphids on Bt plants resulted in an increased production of honeydew that can be used as food by beneficial insects. Indeed, Cotesia marginiventris, a parasitoid of lepidopteran pests, lived longer and parasitized more pest caterpillars in the presence of aphid-infested Bt maize than in the presence of aphid-infested isogenic maize. Hence, depending on aphid pest thresholds, the observed increased susceptibility of Bt maize to aphids may be either a welcome or an undesirable side effect.

  1. Ileal Crohn disease: mural microvascularity quantified with contrast-enhanced US correlates with disease activity.

    Science.gov (United States)

    De Franco, Antonio; Di Veronica, Alessandra; Armuzzi, Alessandro; Roberto, Italia; Marzo, Manuela; De Pascalis, Barbara; De Vitis, Italo; Papa, Alfredo; Bock, Enrico; Danza, Francesco M; Bonomo, Lorenzo; Guidi, Luisa

    2012-02-01

    To quantitatively assess microvascular activation in the thickened ileal walls of patients with Crohn disease (CD) by using contrast-enhanced ultrasonography (US) and evaluate its correlation with widely used indexes of CD activity. This prospective study was approved by the ethics committee, and written informed consent was obtained from all patients. The authors examined 54 consecutively enrolled patients (mean age, 35.29 years; age range, 18-69 years; 39 men, 15 women) with endoscopically confirmed CD of the terminal ileum. Ileal wall segments thicker than 3 mm were examined with low-mechanical-index contrast-enhanced US and a second-generation US contrast agent. The authors analyzed software-plotted time-enhancement intensity curves to determine the maximum peak intensity (MPI) and wash-in slope coefficient (β) and evaluated their correlation with (a) the composite index of CD activity (CICDA), (b) the CD activity index (CDAI), and (c) the simplified endoscopic score for CD (SES-CD, evaluated in 37 patients) for the terminal ileum. Statistical analysis was performed with the Mann-Whitney test, Spearman rank test, and receiver operating characteristic (ROC) analysis. MPI and β coefficients were significantly increased in the 36 patients with a CICDA indicative of active disease (P<.0001 for both), the 33 patients with a CDAI of at least 150 (P<.032 and P<.0074, respectively), and the 26 patients with an SES-CD of at least 1 (P<.0001 and P<.002, respectively). ROC analysis revealed accurate identification (compared with CICDA) of active CD with an MPI threshold of 24 video intensity (VI) (sensitivity, 97%; specificity, 83%) and a β coefficient of 4.5 VI/sec (sensitivity, 86%; specificity, 83%). Contrast-enhanced US of the ileal wall is a promising method for objective, reproducible assessment of disease activity in patients with ileal CD. © RSNA, 2011

  2. Gadolinium Contrast Enhancement Improves Confidence in Diagnosing Recurrent Soft Tissue Sarcoma by MRI.

    Science.gov (United States)

    Chou, Shinn-Huey S; Hippe, Daniel S; Lee, Amie Y; Scherer, Kurt; Porrino, Jack A; Davidson, Darin J; Chew, Felix S; Ha, Alice S

    2017-05-01

    To determine how utilization of postgadolinium magnetic resonance imaging (MRI) influenced reader accuracy and confidence at identifying postoperative soft tissue sarcoma (STS) recurrence among readers with various levels of expertise. This retrospective study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Postoperative MRI from 26 patients with prior STS resection (13 patients with confirmed recurrence, 13 without recurrence) was reviewed. Four blinded readers of varying expertise (radiology resident, fellow, attending, and orthopedic oncologist) initially evaluated only the precontrast images and rated each MRI for recurrence on a 5-point confidence scale. Assessment was repeated with the addition of contrast-enhanced sequences. Diagnostic accuracy based on confidence ratings was evaluated using the area under the receiver operating characteristic curve (AUC). Changes in confidence ratings were calculated using Wilcoxon signed-rank test. All readers demonstrated good diagnostic accuracy both with and without contrast-enhanced images (AUC >0.98 for each reader). When contrast-enhanced images were made available, the resident recorded improved confidence with both assigning (P = 0.031) and excluding recurrence (P = 0.006); the fellow showed improved confidence only with assigning recurrence (P = 0.015); and the surgeon showed improved confidence in excluding recurrence (P = 0.003). The addition of contrast-enhanced images did not significantly influence the diagnostic confidence of the attending radiologist. Diagnostic accuracy of MRI was excellent in evaluating postoperative STS recurrence, and reader confidence improved depending on expertise when postgadolinium imaging was included in the assessment. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Diagnostic and prognostic values of contrast-enhanced ultrasound in breast cancer: a retrospective study

    OpenAIRE

    Zhao YX; Liu S.; Hu YB; Ge YY; Lv DM

    2017-01-01

    Yi-Xuan Zhao, Shuang Liu, Yan-Bing Hu, Yan-Yan Ge, Dong-Mei Lv Department of Ultrasound, Second Hospital, Jilin University, Changchun, People’s Republic of China Abstract: This study aimed to explore the diagnostic and prognostic values of contrast-enhanced ultrasound (CEUS) in breast cancer. Between September 2009 and October 2011, a total of 143 breast cancer patients and 161 healthy people were selected as case group and control group, respectively. After the identific...

  4. Contrast-enhanced magnetic resonance angiography for preoperative imaging in DIEP flap breast reconstruction.

    Science.gov (United States)

    Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; Perks, Graeme B; Akhtar, Nadeem; Rodrigues, Jeremy N; Benetatos, Konstantinos; Raurell, Anna; Rasheed, Tuabin; McCulley, Stephen J

    2011-07-01

    Contrast-enhanced magnetic resonance angiography has been shown to be very accurate for identifying the perforator size, location, and intramuscular course, and the associated venous system, without exposing the patient to ionizing radiation. This study reports the authors' experience using this imaging modality in a large patient series. A retrospective review of patients who had undergone preoperative contrast-enhanced magnetic resonance angiography followed by free abdominal flap breast reconstruction was conducted. The results of imaging were compared with intraoperative findings, and surgical outcomes were compared with scan data. The results were compared with control data in patients who did not undergo presurgical imaging. One hundred thirty-two patients underwent contrast-enhanced magnetic resonance angiography presurgical imaging, and the results were compared with 84 controls. The imaging was found to be accurate for evaluating the perforator anatomy for free abdominal flap planning, with a high concordance between imaging and intraoperative findings. Without presurgical angiography, the ratio of deep inferior epigastric perforator (DIEP) flap-to-free transverse rectus abdominis musculocutaneous flap harvest was 0.9:1; with presurgical imaging, the ratio was 1.6:1 (p angiography, there was a mean reduction in operating time of 26 minutes for unilateral DIEP flap harvest and 40 minutes for bilateral harvest, although these values were not significant. There was a significant reduction in the partial flap failure rate with preoperative imaging. Presurgical imaging using contrast-enhanced magnetic resonance angiography demonstrates a high concordance with intraoperative findings. In this series, the percentage of flaps that were raised as DIEP flaps was significantly increased in patients who underwent preoperative imaging, and the partial flap failure rate was significantly reduced. : Therapeutic, III.(Figure is included in full-text article.).

  5. A monte carlo comparison of three different media for contrast enhanced radiotherapy of the prostate.

    Science.gov (United States)

    Garnica-Garza, H M

    2010-06-01

    Contrast-enhanced radiotherapy makes use of a kilovoltage X-ray beam, either from a diagnostic X-ray tube or modified megavoltage linear accelerator, in conjunction with a high-Z contrast medium deposited into the target volume to enhance the absorption of radiation. In this work, using the Monte Carlo code PENELOPE and the voxelized Zubal phantom to model a prostate radiotherapy treatment, a comparison between the physical absorbed dose distributions rendered by three different enhancing agents namely bismuth, gadolinium, and iodine is performed. It is assumed that there exists a concentration of 10 mg of enhancing agent per 1 g of tissue in the target volume while in the background a concentration of 1.5 mg per 1 g of tissue is present. The X-ray beam energy spectrum was obtained by means of Monte Carlo simulation of a tungsten target upon which a 220 keV mono-energetic electron pencil beam is made to impinge, and the resultant photon beam is heavily filtrated by 0.2 cm of copper. The treatment delivery is simulated as a 3608 arc collimated to conform to the target from every direction. Cumulative dose-volume histograms and isodose curves are presented for the target as well as five organs-at-risk, namely rectal wall, bladder, femoral heads, skin, and bone marrow. It is shown that under these conditions clinically acceptable treatment plans are obtained for all three contrast agents. A 72 Gy dose to 100% of the target volume results in maximum absorbed doses to the above mentioned organs-at-risk of 65, 56, 44, 32 and 65 Gy respectively when bismuth is used as the contrast agent, but the results obtained with gadolinium follow closely.

  6. The clinical use of contrast-enhanced ultrasound in the kidney

    OpenAIRE

    Tenant, Sean C; Gutteridge, Catherine M

    2016-01-01

    Traditional B-Mode and Doppler sonography have been the stalwart of renal tract imaging for many years, and indeed, are in daily use in most centres as the modality of choice for the initial assessment of renal pathology. However, traditional ultrasound scanning can be limited in its ability to accurately characterise renal pathology, and can be inaccurate at determining benign from malignant lesions. Contrast-enhanced ultrasound conveys many benefits, being safe (especially in patients with ...

  7. Giant Congenital Intrapericardial Left Atrial Aneurysm Diagnosed by Contrast-Enhanced Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Taori, K.; Deshmukh, A.; Sanyal, R.; Saini, T.; Sheorain, V.; Rathod, J. [Government Medical College H, Nagpur (India). Dept. of Radiodiagnosis

    2006-07-15

    A left atrial aneurysm is a rare cardiac anomaly. The etiology is usually congenital, but it can also occur as an acquired pathology secondary to mitral valve disease or a degenerative process. We report a case which, on routine PA chest radiography, presented as cardiomegaly with a bulge on the left cardiac contour. Further evaluation by contrast-enhanced computed tomography proved it to be caused by a large left atrial aneurysm.

  8. Three-Dimensional Characterization of Tissue-Engineered Constructs by Contrast-Enhanced Nanofocus Computed Tomography

    OpenAIRE

    Papantoniou, Ioannis; Sonnaert, Maarten; Geris, Liesbet; Luyten, Frank P.; Schrooten, Jan; Kerckhofs, Greet

    2014-01-01

    To successfully implement tissue-engineered (TE) constructs as part of a clinical therapy, it is necessary to develop quality control tools that will ensure accurate and consistent TE construct release specifications. Hence, advanced methods to monitor TE construct properties need to be further developed. In this study, we showed proof of concept for contrast-enhanced nanofocus computed tomography (CE-nano-CT) as a whole-construct imaging technique with a noninvasive potential that enables th...

  9. Spleen evaluation using contrast enhanced ultrasonography and Doppler in dogs with subclinical ehrlichiosis

    OpenAIRE

    Maronezi,M.C.; Feliciano,M.A.R.; Crivellenti,L.Z.; Borin-Crivellenti,S.; Silva,P.E.S.; Zampolo,C.; Pavan,L.; Gasser,B.; Simões,A.P.R.; Maciel,G.S.; Canola,J.C.; Vicente,W.R.R.

    2015-01-01

    The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, ...

  10. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Science.gov (United States)

    Ilunga-Mbuyamba, Elisee; Avina-Cervantes, Juan Gabriel; Lindner, Dirk; Cruz-Aceves, Ivan; Arlt, Felix; Chalopin, Claire

    2016-01-01

    In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS) data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR) data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUSstart) and after (3D-iCEUSend) tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUSstart and 3D-iCEUSend data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation). Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified. PMID:27070610

  11. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Directory of Open Access Journals (Sweden)

    Elisee Ilunga-Mbuyamba

    2016-04-01

    Full Text Available In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUS s t a r t and after (3D-iCEUS e n d tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUS s t a r t and 3D-iCEUS e n d data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation. Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified.

  12. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography.

    Science.gov (United States)

    Diekmann, Felix; Bick, Ulrich

    2007-12-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation.

  13. Ultrasound elastography and contrast-enhanced ultrasound in infants, children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin, E-mail: martin.stenzel@med.uni-jena.de; Mentzel, Hans-Joachim

    2014-09-15

    Objective: To describe prerequisites, use, and safety of ultrasound elastography and contrast-enhanced ultrasound in infants, children, and adolescents. Method: This review deals with two latest developments in ultrasonography in children. The principle of strain elastography, transient elastography, and acoustic radiation force imaging is discussed, including limitations, and advantages of the different techniques in diagnosing focal and diffuse organ disease. The intravesical (contrast-enhanced voiding ultrasonography) and intravascular use of contrast-media to outline blood, and urinary flow is described, with special emphasis on indications, off-label use, and diagnostic gain. Examples of indications for performing the advanced ultrasound techniques are presented. Summary and conclusion: Latest developments in ultrasound machine engineering, and the availability of contrast-media that interact with ultrasound waves allow for assessment of tissue stiffness/elasticity properties, blood, and urinary flow. Thereby ultrasound is capable not only to depict morphology, but gives the additional information on organ, and focal lesion perfusion, and urinary flow dynamics. The information gap to other cross-sectional techniques such as magnetic resonance imaging, that make potential harmful sedation, and anaesthesia in the youngest children necessary, thereby gets closer.

  14. Adaptive luminance contrast for enhancing reading performance and visual comfort on smartphone displays

    Science.gov (United States)

    Na, Nooree; Suk, Hyeon-Jeong

    2014-11-01

    This study developed a model for setting the adaptive luminance contrast between text and background for enhancing reading performance and visual comfort on smartphone displays. The study was carried out in two experiments. In Experiment I, a user test was conducted to identify the optimal luminance contrast with regard to subjects' reading performance, measured by lines of text reading and visual comfort, assessed by self-report after the reading. Based on the empirical results of the test, an ideal adaptive model which decreases the luminance contrast gradually with passage of time was developed. In Experiment II, a validation test involving reading performance, visual comfort, and physiological stress measured by a brainwave analysis using an electroencephalogram confirmed that the proposed adaptive luminance contrast is adequate for prolonged text reading on smartphone displays. The developed model enhances both reading performance and visual comfort as well as reduces the energy consumption of a smartphone; hence, it is expected that this study will be applied to diverse kinds of visual display terminals.

  15. Reverse contrast enhancement in digital radiography in detection of vertical root fracture (in vitro

    Directory of Open Access Journals (Sweden)

    Sandra Mehralizadeh

    2015-07-01

    Full Text Available Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse contrast enhancement options in digital radiography, and to compare it with the original images to find a suitable method to detect vertical root fracture.   Materials and Methods: In this experimental study, digital radiography with phosphor plate detector was taken from 40 extracted single root teeth. From each intact and fractured tooth, the original and reverse contrast images captured and stored. Two expert observers viewed the images twice with an interval of two weeks. Diagnostic criteria (Accuracy, PPV, NPV, Specificity and Sensitivity in form of absolute and complete for each observer and each images was calculated. Inter and intra observer reliability was obtained using Mc-Nemar test.   Results: No significant differences in inter-observer reliability between the initial appearance and reverse contrast was observed (P>0.05, but in view of the intra-observer reliability in two cases, the difference was significant (P0.05, whereas significant difference between the two images was found in NPV index (P<0.05.   Conclusion: The use of reverse contrast enhancement option for detection of vertical root fracture did not show significant difference from initial view.

  16. Reversible and Asymptomatic Gyral and Subarachnoid Contrast Enhancement after Carotid Stenting

    Science.gov (United States)

    Vangosa, Alessandra Briatico; Tortora, Domenico; Modestino, Francesco; Cotroneo, Antonio R

    2015-01-01

    The presence of sulcal hyperdensity in patients after endovascular procedures is not necessarily attributable to hemorrhage. It may frequently indicate the absolute or concomitant extravasation of contrast material into the subarachnoid spaces. This case report describes the clinical case of an 84-year-old patient with 90% stenosis of the right internal carotid who presented with a diffuse gyral and sulcal hyperdensity in the right temporal-occipital and frontal lobes at routine post-carotid stenting (CAS) brain CT scan. The patient was asymptomatic and CT findings were interpreted as contrast enhancement hyperattenuation and no therapeutic decisions were made. A 24-hour follow-up brain CT demonstrated the complete resolution of the hyperdensity, confirming the diagnosis. In this patient we considered the concomitant presence of gyral and sulcal hyperdensity as the consequence of reversible damage to the blood-brain barrier (BBB) determining a transitory extravasation of contrast material. Asymptomatic gyral and subarachnoid contrast enhancement following CAS is generally indicative of benign and transitory damage to the BBB and is not to be misinterpreted as hemorrhage. PMID:25923674

  17. Method of Improved Fuzzy Contrast Combined Adaptive Threshold in NSCT for Medical Image Enhancement

    Directory of Open Access Journals (Sweden)

    Fei Zhou

    2017-01-01

    Full Text Available Noises and artifacts are introduced to medical images due to acquisition techniques and systems. This interference leads to low contrast and distortion in images, which not only impacts the effectiveness of the medical image but also seriously affects the clinical diagnoses. This paper proposes an algorithm for medical image enhancement based on the nonsubsampled contourlet transform (NSCT, which combines adaptive threshold and an improved fuzzy set. First, the original image is decomposed into the NSCT domain with a low-frequency subband and several high-frequency subbands. Then, a linear transformation is adopted for the coefficients of the low-frequency component. An adaptive threshold method is used for the removal of high-frequency image noise. Finally, the improved fuzzy set is used to enhance the global contrast and the Laplace operator is used to enhance the details of the medical images. Experiments and simulation results show that the proposed method is superior to existing methods of image noise removal, improves the contrast of the image significantly, and obtains a better visual effect.

  18. Method of Improved Fuzzy Contrast Combined Adaptive Threshold in NSCT for Medical Image Enhancement.

    Science.gov (United States)

    Zhou, Fei; Jia, ZhenHong; Yang, Jie; Kasabov, Nikola

    2017-01-01

    Noises and artifacts are introduced to medical images due to acquisition techniques and systems. This interference leads to low contrast and distortion in images, which not only impacts the effectiveness of the medical image but also seriously affects the clinical diagnoses. This paper proposes an algorithm for medical image enhancement based on the nonsubsampled contourlet transform (NSCT), which combines adaptive threshold and an improved fuzzy set. First, the original image is decomposed into the NSCT domain with a low-frequency subband and several high-frequency subbands. Then, a linear transformation is adopted for the coefficients of the low-frequency component. An adaptive threshold method is used for the removal of high-frequency image noise. Finally, the improved fuzzy set is used to enhance the global contrast and the Laplace operator is used to enhance the details of the medical images. Experiments and simulation results show that the proposed method is superior to existing methods of image noise removal, improves the contrast of the image significantly, and obtains a better visual effect.

  19. Evaluation of Feline Renal Perfusion with Contrast-Enhanced Ultrasonography and Scintigraphy

    Science.gov (United States)

    Vanderperren, Katrien; Bosmans, Tim; Dobbeleir, André; Duchateau, Luc; Hesta, Myriam; Lybaert, Lien; Peremans, Kathelijne; Vandermeulen, Eva; Saunders, Jimmy

    2016-01-01

    Contrast-enhanced ultrasound (CEUS) is an emerging technique to evaluate tissue perfusion. Promising results have been obtained in the evaluation of renal perfusion in health and disease, both in human and veterinary medicine. Renal scintigraphy using 99mTc-Mercaptoacetyltriglycine (MAG3) is another non-invasive technique that can be used to evaluate renal perfusion. However, no data are available on the ability of CEUS or 99mTc- MAG3 scintigraphy to detect small changes in renal perfusion in cats. Therefore, both techniques were applied in a normal feline population to evaluate detection possibilities of perfusion changes by angiotensin II (AT II). Contrast-enhanced ultrasound using a bolus injection of commercially available contrast agent and renal scintigraphy using 99mTc-MAG3 were performed in 11 healthy cats after infusion of 0,9% NaCl (control) and AT II. Angiotensin II induced changes were noticed on several CEUS parameters. Mean peak enhancement, wash-in perfusion index and wash-out rate for the entire kidney decreased significantly after AT II infusion. Moreover, a tendency towards a lower wash-in area-under-the curve was present. Renal scintigraphy could not detect perfusion changes induced by AT II. This study shows that CEUS is able to detect changes in feline renal perfusion induced by AT II infusion. PMID:27736928

  20. [Application of dynamic contrast enhancement MRI and post-processing technique for diagnosis of breast cancer].

    Science.gov (United States)

    Peng, Kang-Qiang; Huang, Zi-Lin; Xie, Chuan-Miao; Chen, Lin; Ouyang, Yi; Zheng, Qing-Sheng; Zhang, Yan; He, Hao-Qiang; Wu, Pei-Hong

    2009-05-01

    Magnetic resonance imaging (MRI), an advanced non-invasive technique, is regarded as one of the potential modalities in the diagnosis of breast cancer. This study was to investigate the application of dynamic contrast enhancement MRI and 3D reconstruction images in diagnosing breast tumors. From May 2006 to September 2007, 30 patients with breast diseases were scanned with MRI in Sun Yat-sen University Cancer Center. MR plain scans, dynamic contrast enhancement scans were performed, and 3D reconstruction images were obtained. The normal breast tissue was used as control, and the maximum slope ratio was calculated. Forty-nine lesions were found in 30 patients, with an accuracy rate of 93.3%. MRI scan is an effective and specific modality for the diagnosis of breast diseases with high sensitivity and accuracy. Dynamic contrast enhancement MRI, image subtraction, time-signal intensity curve, 3D reconstruction images and the maximum slope ratio are helpful to make the correct diagnosis of breast lesions.

  1. Visualization of thermal ablation lesions using cumulative dynamic contrast enhancement MRI.

    Science.gov (United States)

    Shmatukha, Andriy; Sethi, Benu; Shurrab, Mohammed; Ghate, Sudip; Qi, Xiuling; Barry, Jennifer; Wright, Graham; Crystal, Eugene

    2013-05-21

    A novel robust and user friendly method for post-processing dynamic contrast enhanced (DCE) MRI data is presented, which provides reliable real-time delineation of the borders of thermal ablation lesions on low SNR images shortly after contrast agent injection without any model-based curve fitting. Some simple descriptors of the DCE process are calculated in a time efficient recursive manner and combined into a single image reflecting both current and previous enhancement states of each pixel, which allows robust discrimination between tissue areas with different perfusion properties. The resulting cumulative DCE (CDCE) images are shown to exhibit a strong correlation with histopathology and late gadolinium enhancement representations of the thermal damage in soft tissue. It is shown that the outer border of the non-perfused ablation lesion core on CDCE MRI corresponds to the histopathological lesion border. The described method has a potential not only to facilitate thermal ablation outcome assessment, but also to improve detection of infiltrative tumours and reduce the administered contrast agent dose in any DCE scans.

  2. Breast contrast-enhanced MR imaging: semiautomatic detection of vascular map.

    Science.gov (United States)

    Fusco, Roberta; Sansone, Mario; Filice, Salvatore; Petrillo, Antonella

    2016-03-01

    The diagnostic value of breast vascular maps using contrast-enhanced MR imaging has recently been explored. We propose a semiautomatic method to obtain breast vascular maps and to measure the number of blood vessels in the breast. From January 2011 to December 2013, 188 patients underwent breast contrast-enhanced MRI; patients with unilateral and histopathologically confirmed breast lesions were included in this study; 123 patients had malignant lesions and 65 patients had benign tissue diagnoses. Breast semiautomatic vascular map detection was performed using Hessian matrix-based method and morphologic operators. Blood vessels detection was compared with radiologic interpretation findings to evaluate algorithm goodness. Increase in vascularity associated with ipsilateral cancer was also assessed. Chi square test was used to observe statistically significant difference. A total of 1315 blood vessels were identified using semiautomatic procedure; 1034 were correctly classified (78.7 %), 261 (19.8 %) were incorrectly classified, and 20 (1.5 %) were missing. A significant association was found between one-sided increased breast vascularity and ipsilateral malignancy (p breast cancer could be performed with semiautomatic vascular mapping of contrast-enhanced MR imaging.

  3. Leptomeningeal Contrast Enhancement Is Associated with Disability Progression and Grey Matter Atrophy in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gleb Makshakov

    2017-01-01

    Full Text Available Leptomeningeal contrast enhancement (LMCE on magnetic resonance imaging (MRI is a newly recognized possible biomarker in multiple sclerosis (MS, associated with MS progression and cortical atrophy. In this study, we aimed to assess the prevalence of LMCE foci and their impact on neurodegeneration and disability. Materials. 54 patients with MS were included in the study. LMCE were detected with a 3 Tesla scanner on postcontrast fluid-attenuated inversion-recovery (FLAIR sequence. Expanded Disability Status Scale (EDSS score, number of relapses during 5 years from MS onset, and number of contrast-enhancing lesions on T1 weighted MRI were counted. Results. LMCE was detected in 41% (22/54 of patients. LMCE-positive patients had longer disease duration (p=0,0098 and higher EDSS score (p=0,039, but not a higher relapse rate (p=0,091. No association of LMCE with higher frequency of contrast-enhancing lesions on T1-weighted images was detected (p=0,3842. Analysis of covariates, adjusted for age, sex, and disease duration, revealed a significant effect of LMCE on the cortex volume (p=0.043, F=2.529, the total grey matter volume (p=0.043, F=2.54, and total ventricular volume (p=0.039, F=2.605. Conclusions. LMCE was shown to be an independent and significant biomarker of grey matter atrophy and disability in MS.

  4. Statistical comparison of dynamic contrast-enhanced MRI pharmacokinetic models in human breast cancer.

    Science.gov (United States)

    Li, Xia; Welch, E Brian; Chakravarthy, A Bapsi; Xu, Lei; Arlinghaus, Lori R; Farley, Jaime; Mayer, Ingrid A; Kelley, Mark C; Meszoely, Ingrid M; Means-Powell, Julie; Abramson, Vandana G; Grau, Ana M; Gore, John C; Yankeelov, Thomas E

    2012-07-01

    By fitting dynamic contrast-enhanced MRI data to an appropriate pharmacokinetic model, quantitative physiological parameters can be estimated. In this study, we compare four different models by applying four statistical measures to assess their ability to describe dynamic contrast-enhanced MRI data obtained in 28 human breast cancer patient sets: the chi-square test (χ(2)), Durbin-Watson statistic, Akaike information criterion, and Bayesian information criterion. The pharmacokinetic models include the fast exchange limit model with (FXL_v(p)) and without (FXL) a plasma component, and the fast and slow exchange regime models (FXR and SXR, respectively). The results show that the FXL_v(p) and FXR models yielded the smallest χ(2) in 45.64 and 47.53% of the voxels, respectively; they also had the smallest number of voxels showing serial correlation with 0.71 and 2.33%, respectively. The Akaike information criterion indicated that the FXL_v(p) and FXR models were preferred in 42.84 and 46.59% of the voxels, respectively. The Bayesian information criterion also indicated the FXL_v(p) and FXR models were preferred in 39.39 and 45.25% of the voxels, respectively. Thus, these four metrics indicate that the FXL_v(p) and the FXR models provide the most complete statistical description of dynamic contrast-enhanced MRI time courses for the patients selected in this study. Copyright © 2011 Wiley Periodicals, Inc.

  5. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  6. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  7. The Effects of Applying Breast Compression in Dynamic Contrast Material–enhanced MR Imaging

    Science.gov (United States)

    Macura, Katarzyna J.; Kamel, Ihab R.; Bluemke, David A.; Jacobs, Michael A.

    2014-01-01

    Purpose To evaluate the effects of breast compression on breast cancer masses, contrast material enhancement of glandular tissue, and quality of magnetic resonance (MR) images in the identification and characterization of breast lesions. Materials and Methods This was a HIPAA-compliant, institutional review board–approved retrospective study, with waiver of informed consent. Images from 300 MR imaging examinations in 149 women (mean age ± standard deviation, 51.5 years ± 10.9; age range, 22–76 years) were evaluated. The women underwent diagnostic MR imaging (no compression) and MR-guided biopsy (with compression) between June 2008 and February 2013. Breast compression was expressed as a percentage relative to the noncompressed breast. Percentage enhancement difference was calculated between noncompressed- and compressed-breast images obtained in early and delayed contrast-enhanced phases. Breast density, lesion type (mass vs non-masslike enhancement [NMLE]), lesion size, percentage compression, and kinetic curve type were evaluated. Linear regression, receiver operating characteristic (ROC) curve analysis, and κ test were performed. Results Mean percentage compression was 31.3% ± 9.2 (range, 5.8%–53.2%). Percentage enhancement was higher in noncompressed- versus compressed-breast studies in early (146% ± 66 vs 107% ± 42, respectively; P breast lesions, 12% (seven of 59) were significantly smaller when compressed, which led to underestimation of TNM classification (P Breast masses (n = 35) showed significantly higher early percentage enhancement (157% ± 71) than lesions with NMLE (n = 15, 120% ± 40; P = .02) and a percentage enhancement difference (47.5% ± 64 vs 17% ± 28, respectively; P = .023). Kinetic curve performance for identifying invasive cancer decreased after compression (area under ROC curve = 0.53 vs 0.71, respectively; P = .02). Breast compression resulted in complete loss of enhancement of nine of 210 lesions (4%). Conclusion Breast

  8. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2007-01-15

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  9. CT findings in autoimmune pancreatitis: assessment using multiphase contrast-enhanced multisection CT

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K., E-mail: Kojiro@med.nagoya-u.ac.j [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Nagoya Hirokoji Clinic, Nagoya (Japan); Nagasaka, T. [Departments of Medical Technology, Nagoya University School of Health Science, Nagoya (Japan); Ogawa, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2010-09-15

    Aim: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). Materials and methods: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. Results: The pancreas showed diffuse enlargement (n = 16; 32%), focal enlargement (n = 18; 36%), or no enlargement (n = 16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n = 45; 90%) and hyperattenuation during the delayed phase (n = 39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n = 24; 48%); no visualization of the main pancreatic duct lumen (n = 48; 96%); ductal enhancement (n = 26; 52%); upstream dilatation of the main pancreatic duct (n = 27; 54%); upstream atrophy of the pancreatic parenchyma (n = 27; 54%); calcification (n = 7; 14%); and cysts (n = 5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n = 40; 80%); peripancreatic (n = 8; 16%) or para-aortic (n = 10; 20%) soft-tissue proliferation; and renal involvement (n = 15; 30%). Conclusion: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.

  10. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  11. Computed tomography angiography: the effect of different chaser flow rates, volumes, and fluids on contrast enhancement.

    Science.gov (United States)

    Behrendt, Florian F; Jost, Gregor; Pietsch, Hubertus; Keil, Sebastian; Mottaghy, Felix M; Günther, Rolf W; Mahnken, Andreas H

    2011-04-01

    The aim of this study was to intraindividually compare the effect of different chaser flow rates, volumes, and fluids on contrast enhancement in multidetector-row computed tomography. Multidetector-row computed tomography scanning of 5 dogs was performed under standardized conditions using an adapted injection protocol to ensure an identical iodine delivery rate of 1.0 gI/s and a total iodine dose of 300 mg/kg body weight (iopromide 300 and 370). The contrast medium application was followed by a 10-mL saline chaser at different injection rates (0, 2.7, 4, 6, and 8 mL/s) or by different saline chaser volumes (0, 5, 10, and 15 mL) at a flow rate of 4 mL/s. Furthermore, different chaser fluids (NaCl, hydroxyethyl starch 10%, and Dextran 1%) with different viscosities (hydroxyethyl starch 10% and dextran 1%: 3.28 and 5.98 mPa · s at 37°C) were tested (volume: 10 mL; flow rate: 6 mL/s). Each dog was examined with each protocol. The interval between each computed tomography scan session which included 2 measurements was at least 3 days. Dynamic computed tomography scans were acquired at the level of the cephalic vein, cranial vena cava, pulmonary artery, and ascending and descending aorta. Time-enhancement curves were computed, and pulmonary and aortic peak enhancements as well as time-to-peak were analyzed. Increased saline chaser flow rates or increased saline chaser volumes resulted in increased pulmonary and aortic peak contrast enhancement. Peak enhancement was highest and significantly greater compared with no saline chaser for a flow rate of 8 mL/s (pulmonary artery: 816.8 vs. 471.5 HU, P = 0.0079; ascending aorta: 578.7 vs. 384.1 HU, P = 0.0079; descending aorta: 581.4 HU vs. 390.6 HU, P = 0.0159) and a saline volume of 15 mL (pulmonary artery: 670.2 vs. 453.5 HU, P = 0.0079; ascending aorta: 512.1 vs. 370.6 HU, P = 0.0317; descending aorta: 504.0 HU vs. 394.4 HU, P = 0.0159). No significant differences between the peak times for different saline chasers were

  12. Equal pain – Unequal fear response: Enhanced susceptibility of tooth pain to fear conditioning

    Directory of Open Access Journals (Sweden)

    Michael Lukas Meier

    2014-07-01

    Full Text Available Experimental fear conditioning in humans is widely used as a model to investigate the neural basis of fear learning and to unravel the pathogenesis of anxiety disorders. It has been observed that fear conditioning depends on stimulus salience and subject vulnerability to fear. It is further known that the prevalence of dental-related fear and phobia is exceedingly high in the population. Dental phobia is unique as no other body part is associated with a specific phobia. Therefore, we hypothesized that painful dental stimuli exhibit an enhanced susceptibility to fear conditioning when comparing to equal perceived stimuli applied to other body sites. Differential susceptibility to pain-related fear was investigated by analyzing responses to an unconditioned stimulus (UCS applied to the right maxillary canine (UCS-c versus the right tibia (UCS-t. For fear conditioning, UCS-c and USC-t consisted of painful electric stimuli, carefully matched at both application sites for equal intensity and quality perception. UCSs were paired to simple geometrical forms which served as conditioned stimuli (CS+. Unpaired CS+ were presented for eliciting and analyzing conditioned fear responses. Outcome parameter were 1 skin conductance changes and 2 time-dependent brain activity (BOLD responses in fear-related brain regions such as the amygdala, anterior cingulate cortex, insula, thalamus, orbitofrontal cortex and medial prefrontal cortex.A preferential susceptibility of dental pain to fear conditioning was observed, reflected by heightened skin conductance responses and enhanced time-dependent brain activity (BOLD responses in the fear network. For the first time, this study demonstrates fear-related neurobiological mechanisms that point towards a superior conditionability of tooth pain. Beside traumatic dental experiences our results offer novel evidence that might explain the high prevalence of dental-related fears in the population.

  13. LTP3 contributes to disease susceptibility in Arabidopsis by enhancing abscisic acid (ABA) biosynthesis.

    Science.gov (United States)

    Gao, Shan; Guo, Wenya; Feng, Wen; Liu, Liang; Song, Xiaorui; Chen, Jian; Hou, Wei; Zhu, Hongxia; Tang, Saijun; Hu, Jian

    2016-04-01

    Several plant lipid transfer proteins (LTPs) act positively in plant disease resistance. Here, we show that LTP3 (At5g59320), a pathogen and abscisic acid (ABA)-induced gene, negatively regulates plant immunity in Arabidopsis. The overexpression of LTP3 (LTP3-OX) led to an enhanced susceptibility to virulent bacteria and compromised resistance to avirulent bacteria. On infection of LTP3-OX plants with Pseudomonas syringae pv. tomato, genes involved in ABA biosynthesis, NCED3 and AAO3, were highly induced, whereas salicylic acid (SA)-related genes, ICS1 and PR1, were down-regulated. Accordingly, in LTP3-OX plants, we observed increased ABA levels and decreased SA levels relative to the wild-type. We also showed that the LTP3 overexpression-mediated enhanced susceptibility was partially dependent on AAO3. Interestingly, loss of function of LTP3 (ltp3-1) did not affect ABA pathways, but resulted in PR1 gene induction and elevated SA levels, suggesting that LTP3 can negatively regulate SA in an ABA-independent manner. However, a double mutant consisting of ltp3-1 and silent LTP4 (ltp3/ltp4) showed reduced susceptibility to Pseudomonas and down-regulation of ABA biosynthesis genes, suggesting that LTP3 acts in a redundant manner with its closest homologue LTP4 by modulating the ABA pathway. Taken together, our data show that LTP3 is a novel negative regulator of plant immunity which acts through the manipulation of the ABA-SA balance. © 2015 BSPP and John Wiley & Sons Ltd.

  14. Association between Parenchymal Enhancement of the Contralateral Breast in Dynamic Contrast-enhanced MR Imaging and Outcome of Patients with Unilateral Invasive Breast Cancer

    NARCIS (Netherlands)

    van der Velden, Bas; Dmitriev, Ivan; Loo, C.E.; Pijnappel, Ruud; Gilhuijs, Kenneth

    2015-01-01

    Purpose To retrospectively investigate whether parenchymal enhancement in dynamic contrast material–enhanced magnetic resonance (MR) imaging of the contralateral breast in patients with unilateral invasive breast cancer is associated with therapy outcome. Materials and Methods After obtaining

  15. Enhancement of ultrasound reflectivity depends on the specific perfluorocarbons utilized to formulate nanoparticle emulsion contrast agents

    Science.gov (United States)

    Marsh, Jon N.; Hall, Christopher S.; Scott, Michael J.; Fuhrhop, Ralph J.; Gaffney, Patrick J.; Wickline, Samuel A.; Lanza, Gregory M.

    2000-04-01

    A nongaseous, ligand-targeted perfluorocarbon nanoparticle emulsion has been developed which can acoustically enhance the presence of molecular epitopes on tissue surfaces. We demonstrate the impact of incorporating perfluorocarbons with specific phase velocities into the emulsions on the acoustic reflectivity of plasma clots targeted using these nanoparticles. Porcine plasma clots were targeted in vitro with specific perfluorocarbon emulsions using anti-fibrin antibody solution (NIB 5F3). Five perfluorocarbons were investigated: perfluorohexane, perfluorooctyl-bromide, perfluorooctane, perfluorodichlorooctane, and perfluorodecalin. Ultrasonic backscatter (17 - 35 MHz) was measured at the front surface of the clots. Backscatter enhancement was determined by comparison with untreated clots. The magnitude of enhancement depended on the perfluorocarbon emulsion used. Perfluorohexane and perfluorooctane exhibited the greatest enhancement relative to untreated clots (23 dB) and perfluorodecalin the least (18 dB), consistent with predictions from a simple acoustic transmission-line model. We conclude that targeted, nongaseous perfluorocarbon contrast agents can significantly increase the sensitivity of ultrasonic detection of low-scattering biological media, and that further optimization of these contrast agents can be realized by judicious choice of the emulsified perfluorocarbon.

  16. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  17. Contrast-enhanced postmortem computed tomography in clinical pathology: enhanced value of 20 clinical autopsies.

    Science.gov (United States)

    Westphal, Saskia E; Apitzsch, Jonas C; Penzkofer, Tobias; Kuhl, Christiane K; Mahnken, Andreas H; Knüchel, Ruth

    2014-09-01

    Postmortem computed tomography (PMCT) is a modern tool that complements autopsy diagnostics. In clinical autopsies, a major cause of death is cardiovascular disease. To improve the performance of PMCT in cardiovascular disease, full body angiography was developed (PMCT angiography [PMCTA]). Twenty PMCTA scans generated before autopsy were compared with native PMCT and clinical autopsy. The objective of the study was to quantify the additional diagnostic value of adding angiography to native imaging and to compare PMCT and PMCTA findings to autopsy findings. The diagnosis of the cause of death was identical or overlapped in 80% of the cases that used PMCTA and 70% that used PMCT. The additional diagnostic yield given by PMCT and PMCTA in combination with autopsy was 55%. PMCT yielded additional diagnoses in the musculoskeletal system. The greatest additional diagnostic value of PMCTA was in association with cardiovascular diagnoses. The accuracy of PMCTA for cardiac causes of death was 80%, and the positive predictive value was 90%. The findings indicate that native PMCT cannot display the cardiovascular system sufficiently clearly for high-quality diagnostic assessment. However, PMCTA is a powerful tool in autopsy cases with a history of cardiovascular disease and/or a suspected cardiovascular cause of death. The combination of PMCTA and clinical autopsy enhances diagnostic quality and completeness of the autopsy report. Furthermore, in cases without consent or with a restricted consent for clinical autopsy, PMCTA has the potential to provide information on cardiovascular causes of death. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors☆

    Science.gov (United States)

    Sconfienza, L.M.; Perrone, N.; Delnevo, A.; Lacelli, F.; Murolo, C.; Gandolfo, N.; Serafini, G.

    2009-01-01

    Introduction Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. Materials and methods We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. Results In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. Conclusions CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%). PMID:23396092

  19. Interactive lesion segmentation on dynamic contrast enhanced breast MRI using a Markov model

    Science.gov (United States)

    Wu, Qiu; Salganicoff, Marcos; Krishnan, Arun; Fussell, Donald S.; Markey, Mia K.

    2006-03-01

    The purpose of this study is to develop a method for segmenting lesions on Dynamic Contrast-Enhanced (DCE) breast MRI. DCE breast MRI, in which the breast is imaged before, during, and after the administration of a contrast agent, enables a truly 3D examination of breast tissues. This functional angiogenic imaging technique provides noninvasive assessment of microcirculatory characteristics of tissues in addition to traditional anatomical structure information. Since morphological features and kinetic curves from segmented lesions are to be used for diagnosis and treatment decisions, lesion segmentation is a key pre-processing step for classification. In our study, the ROI is defined by a bounding box containing the enhancement region in the subtraction image, which is generated by subtracting the pre-contrast image from 1st post-contrast image. A maximum a posteriori (MAP) estimate of the class membership (lesion vs. non-lesion) for each voxel is obtained using the Iterative Conditional Mode (ICM) method. The prior distribution of the class membership is modeled as a multi-level logistic model, a Markov Random Field model in which the class membership of each voxel is assumed to depend upon its nearest neighbors only. The likelihood distribution is assumed to be Gaussian. The parameters of each Gaussian distribution are estimated from a dozen voxels manually selected as representative of the class. The experimental segmentation results demonstrate anatomically plausible breast tissue segmentation and the predicted class membership of voxels from the interactive segmentation algorithm agrees with the manual classifications made by inspection of the kinetic enhancement curves. The proposed method is advantageous in that it is efficient, flexible, and robust.

  20. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    Energy Technology Data Exchange (ETDEWEB)

    Jakubek, Jan [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Granja, Carlos [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)]. E-mail: carlos.granja@utef.cvut.cz; Dammer, Jiri [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Hanus, Robert [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Holy, Tomas [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Pospisil, Stanislav [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Tykva, Richard [Institute of Organic Chemistry and Biochemistry, Academy of Sciences, CZ-166 10 Prague 6 (Czech Republic); Uher, Josef [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Vykydal, Zdenek [Institute of Experimental and Applied Physis, Czech Technical Universtiy in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic)

    2007-02-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences.

  1. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol [Seoul National Univ., Seoul (Korea, Republic of). Coll. of Medicine

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs.

  2. Use of computed tomographic densitometry to quantify contrast enhancement of compressive soft tissues in the canine lumbosacral vertebral canal.

    Science.gov (United States)

    Jones, Jeryl C; Shires, Peter K; Inzana, Karen D; Mosby, Adina D; Sponenberg, D Philip; Lanz, Otto I

    2002-05-01

    To evaluate computed tomography (CT) densitometry as a technique for quantifying contrast enhancement of compressive soft tissues in the canine lumbosacral vertebral canal and to determine whether the degree of contrast enhancement can be used to help predict tissue type or histopathologic characteristics. 29 large breed dogs with lumbosacral stenosis. Contrast-enhanced CT of L5-S3 was performed by use of a previously described protocol. At each disk level, CT densities of a water-filled syringe, epaxial muscles, and 4 vertebral canal locations were measured. Mean tissue enhancement was calculated by vertebral canal location, using water-filled syringe enhancement as a correction factor. Corrected CT enhancement was compared with tissue type, degree of tissue inflammation, and degree of tissue activity. Intravenous contrast administration of contrast medium significantly increased CT densities of water-filled syringes and epaxial muscles. Corrected CT enhancement of vertebral canal soft tissues at stenotic sites was greater than at nonstenotic sites. There was no association between enhancement and tissue type for any vertebral canal location. There was no correlation between enhancement and degree of tissue inflammation. There was a correlation between enhancement and tissue activity in the dorsal vertebral canal only. A water-filled syringe is a useful calibration tool for CT density measurements. The degree of tissue contrast enhancement, measured by CT densitometry, can be helpful for predicting the location of compressive soft tissues in dogs with lumbosacral stenosis. However, it is of limited value for predicting compressive soft-tissue types or histopathologic characteristics.

  3. An evaluation of the clinical diagnostic value of contrast-enhanced ultrasound combined with contrast-enhanced computed tomography in space-occupying lesions of the kidney.

    Science.gov (United States)

    Tian, Wen; Lu, Jianbo; Jiao, Dan; Cong, Zhibin

    2017-01-01

    There are a variety of space-occupying lesions of the kidney, and the benign lesions may be difficult to differentiate from the malignant ones. Therefore, an accurate judgment of the benign and malignant nature of the space-occupying lesions of the kidney is of high importance for the treatment and prognosis of these patients. To evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) combined with contrast-enhanced computed tomography (CECT) in space-occupying lesions of the kidney. Three hundred and sixty-seven patients with space-occupying lesions of the kidney (378 lesions) were examined by CEUS and CECT, respectively, then, a combined diagnosis was made after the combination of CEUS and CECT by a multidisciplinary team. The diagnoses from the three methods were compared. The pathological results were taken as the gold standard. The sensitivity, specificity, positive and negative predictive values and area under the receiver operating characteristic (ROC) curve were calculated for the three methods. Thus, the diagnostic value of the three methods was assessed. Of the 378 lesions examined, there were 301 malignant lesions and 77 benign lesions. The combined examination revealed 303 malignant lesions, with 9 benign lesions mistakenly diagnosed as malignant ones; thus, the misdiagnosis rate was 11.7%. By using the combined examination, 75 benign lesions were diagnosed, with the missed diagnosis of 7 malignant lesions, so the missed diagnosis rate was 2.3%. The sensitivity, specificity, positive and negative predictive values and area under the ROC curve with the combined examination of CEUS and CECT were 97.67% (0.950-0.989), 88.31% (0.785-0.942), 97.03% (0.942-0.985), 90.67% (0.811-0.958) and 0.930 (0.887-0.973), respectively. As compared with either CEUS or CECT alone, the difference in these indicators was of statistical significance (P<0.05). The combined examination greatly improved the sensitivity, specificity and accuracy of the diagnosis of

  4. Three-dimensional contrast enhanced ultrasound score and dynamic contrast-enhanced magnetic resonance imaging score in evaluating breast tumor angiogenesis: Correlation with biological factors

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Wan-Ru, E-mail: jiawanru@126.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Chai, Wei-Min, E-mail: chai_weimin@yahoo.com.cn [Department of Radiology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Tang, Lei, E-mail: jessietang1003@163.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Wang, Yi, E-mail: xiatian.0602@163.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Fei, Xiao-Chun, E-mail: xcf0222@163.com [Department of Pathology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Han, Bao-San, E-mail: hanbaosan@126.com [Department of Comprehensive Breast Health Center, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Chen, Man, E-mail: lucyjia1370@126.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China)

    2014-07-15

    Objective: To explore the clinical value of three-dimensional contrast enhanced ultrasound (3D-CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) score systems in evaluating breast tumor angiogenesis by comparing their diagnostic efficacy and correlation with biological factors. Methods: 3D-CEUS was performed in 183 patients with breast tumors by Esaote Mylab90 with SonoVue (Bracco, Italy), DCE-MRI was performed on a dedicated breast magnetic resonance imaging (DBMRI) system (Aurora Dedicated Breast MRI Systems, USA) with a dedicated breast coil. 3D-CEUS and DCE-MRI score systems were created based on tumor perfusion and vascular characteristics. Microvessel density (MVD), vascular endothelial growth factor (VEGF) and matrix metalloproteinases (MMP-2, MMP-9) expression were measured by immunohistochemistry. Results: Pathological results showed 35 benign and 148 malignant breast tumors. MVD (P = 0.000, r = 0.76), VEGF (P = 0.000, r = 0.55), MMP-2 (P = 0.000, r = 0.39) and MMP-9 (P = 0.000, r = 0.41) expression were all significantly different between benignity and malignancy. Regarding 3D-CEUS 4 points as cutoff value, the sensitivity, specificity and accuracy were 85.1%, 94.3% and 86.9%, respectively, and correlated well with MVD (P = 0.000, r = 0.50), VEGF (P = 0.000, r = 0.50), MMP-2 (P = 0.000, r = 0.50) and MMP-9 (P = 0.000, r = 0.66). Taking DCE-MRI 5 points as cutoff value, the sensitivity, specificity and accuracy were 86.5%, 94.3% and 88.0%, respectively and also correlated well with MVD (P = 0.000, r = 0.52), VEGF (P = 0.000, r = 0.44), MMP-2 (P = 0.000, r = 0.42) and MMP-9 (P = 0.000, r = 0.35). Conclusions: 3D-CEUS score system displays inspiring diagnostic performance and good agreement with DCE-MRI scoring. Moreover, both score systems correlate well with MVD, VEGF, MMP-2 and MMP-9 expression, and thus have great potentials in tumor angiogenesis evaluation.

  5. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Zhihui, E-mail: fanzhihui_1026@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Li, Ying, E-mail: 18901033676@126.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Radiology, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yan, Kun, E-mail: ydbz@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Wu, Wei, E-mail: wuwei@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yin, Shanshan, E-mail: yshshmd@yahoo.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yang, Wei, E-mail: weiwei02032001@gmail.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Xing, Baocai, E-mail: xinbaocai88@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Hepatic Biliary and Pancreatic Surgery, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); and others

    2013-09-15

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  6. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  7. Contrast-enhanced multislice pneumo-CT-cystography in the evaluation of urinary bladder neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)], E-mail: scardapane@aruba.it; Pagliarulo, Vincenzo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Ianora, Amato A. Stabile [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy); Pagliarulo, Arcangelo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Angelelli, Giuseppe [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)

    2008-05-15

    Purpose: To evaluate the accuracy of contrast-enhanced multislice CT (MSCT) in the study of urothelial tumors after distension of the bladder with air. Materials and methods: We evaluated 43 consecutive patients with endoscopically proven bladder lesions. After air distension of the bladder, unenhanced pelvic and enhanced abdomino-pelvic scans were obtained with the following protocol: thickness 2.5 mm x 4 mm, increment 1 mm, scan delay 40'' and 7-10 min. For each patient we considered the number, size, aspect (papillary or sessile) and contrast enhancement of lesions. Ureteral involvement and the presence of synchronous lesions in the excretory scan were also evaluated. MPR and virtual endoscopy images were reviewed in all cases. Results: Bladder lesions were visualized in 39/43 cases. Compared to conventional cystoscopy, MSCT recognized single lesions in 31/33 patients, two lesions in 4/6, three in 2/2 and more than five foci in 2/2 patients. A papillary aspect was described in 44 cases while 11 lesions were sessile. Conventional Cystoscopy recognized six more lesions as compared with MSCT (four flat and two small papillary lesions). The detection rate for protruding lesions was 100% (52/52) for lesions > 5 mm and 60% (3/5%) for lesions < 5 mm. In four patients hydronephrosis was present, while in one case a synchronous lesion was evident in the renal pelvis. Conclusion: Contrast-enhanced MSCT with air distension of the urinary bladder is a safe and complete investigation to evaluate the local stage of bladder cancer and to evaluate the ureteral extension of the tumor, as well as the presence of synchronous lesions.

  8. [Renal enhancement and excretion of the hepatobiliary contrast agent Gd-EOB-DTPA].

    Science.gov (United States)

    Zangos, S; Hammerstingl, R; Mack, M G; Straub, R; Engelmann, K; Eichler, K; Balzer, T; Vogl, T J

    2001-11-01

    To evaluate the clinical value of the renal clearance using MR imaging with different doses of gadolinium ethoxybenzyl-DTPA (Gd-EOB-DTPA) in comparison to gadolinium DTPA (Gd-DTPA). In a double-blind and randomized clinical phase II study. MR imaging at 1.5 T was performed in 61 patients with five different doses of Gd-EOB-DTPA (3, 6, 12.5, 25 and 50 micromol/kg b. w. as a bolus injection). The study protocol comprised T(1)- and T(2)-weighted spin-echo magnetic resonance and two-dimensional fast low-angle shot imaging before and at increasing intervals for up to 45 min after injection of Gd-EOB-DTPA. These images were compared with Gd-DTPA-enhanced imaging (0.1 mmol/kg b. w. as a bolus injection). After bolus injection of the hepatobiliary MR contrast agent Gd-EOB-DTPA a renal elimination was observed. Immediately after the injection of Gd-EOB-DTPA until the eighth minute a corticomedullary enhancement of the kidney was conspicuous. After the fourth minute a contrast enhancement could be seen in the renal pelvis. The best enhancement was noted after 20 minutes in the FLASH GRE and T(1)-weighted images with good pelvicaliceal contrast. After 45 minutes an outflow of Gd-EOB-DTPA into the ureter could be observed. In addition to the hepatobiliary secretion Gd-EOB-DTPA appears useful for the evaluation of renal structures and renal function on account of the renal excretion without diuretic preparation of the patients.

  9. Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Tartaro, A.; Bonomo, L. [Istituto di Radiologia, Universita di Chieti (Italy); Guglielmi, G. [Istituto di Radiologia, IRCCS, San Giovanni Rotondo (Italy); Di Matteo, L. [Istituto di Reumatologia, Pescara (Italy); Mattei, P.A. [Facolta di Medicina, Universita Chieti (Italy)

    2001-06-01

    The purpose of this study was to first evaluate Levovist (Schering, Berlin, Germany), an echo-contrast agent, during power Doppler sonography (PDS) in patients with synovitis using asymptomatic joints as controls. Then we evaluated the accuracy of this technique against contrast-enhanced MRI. Forty patients (19 men and 21 women; mean age 40 years) were enrolled on the basis of clinical signs, laboratory tests, and radiographic findings positive for articular inflammatory disease. They were examined with conventional ultrasonography (US) and PDS techniques before and after intravenous contrast medium injection. Fourteen patients then underwent MRI with and without contrast medium 8-14 days after PDS studies. Three expert readers independently evaluated each examination. After contrast medium, synovium in inflammatory arthritis enhanced on PDS compared with normal joints in the same patient. Power Doppler sonography after contrast medium and MRI were concordant in all cases. Power Doppler sonography with contrast medium showed a qualitative increase in signal from synovial vessels, the first sign of synovial changes in inflammatory diseases. (orig.)

  10. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Sung, Ji Kyeong [Dept. of Radiology, St. Vincent' s Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2015-12-15

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  11. Generation and modelling of megavoltage photon beams for contrast-enhanced radiation therapy

    Science.gov (United States)

    Robar, J. L.

    2006-11-01

    Contrast-enhanced radiation therapy (CERT) is a treatment approach involving the irradiation of tumours containing high atomic number (Z) contrast media, using low-quality x-ray beams. This work describes the experimental generation of x-ray beams using a linear accelerator with low-Z target materials (beryllium and aluminium), in order to produce photon energy spectra appropriate for CERT. Measurements were made to compare the experimental beams to conventional linear accelerator photon beams in terms of per cent depth dose. Monte Carlo simulation was used to model the generation of each beam, and models were validated against experimental measurement. Validated models were used to demonstrate changes in photon spectra as well as to quantify the variation of tumour dose enhancement with iodinated contrast medium concentration in a simulated tumour volume. Finally, the ratio of the linear attenuation coefficient for iodinated contrast medium relative to water was determined experimentally as a function of iodine concentration. Beams created with low-Z targets show significant changes in energy spectra compared to conventional beams. For the 4 MeV/Be beam, for example, 33% of photons have energies below 60 keV. Measurements and calculation show that both the linear attenuation coefficient ratio and dose enhancement factor (DEF) increase most rapidly at concentrations below 46 mg I ml-1. There is a significant dependence of DEF on electron energy and a lesser dependence on target material. The 4 MeV/Be beam is the most promising in terms of magnitude of DEF—for example, DEF values of 1.16 and 1.29 are obtained for concentrations of 20 mg I ml-1 and 50 mg I ml-1, respectively. DEF will increase or decrease, respectively, for shallower or deeper tumours at a rate of approximately 1.1% cm-1. In summary, we show that significant dose enhancement is possible by altering the linear accelerator target and filtration, but the magnitude is highly dependent on contrast

  12. Contrast-agent-enhanced magnetic resonance imaging: early detection of neoplastic lesions of the CNS

    Science.gov (United States)

    Carvlin, Mark J.; Rosa, Louis; Rajan, Sunder S.; Francisco, John

    1991-06-01

    Even though the intrinsic soft tissue contrast sensitivity of magnetic resonance imaging (MRI) affords excellent visualization of anatomic detail, certain pathologic processes may be diagnosed earlier with the administration of a contrast-enhancing agent. At present there is one agent, gadopentetate dimeglumine, GdDTPA, that has received FDA approval for use in the MR scanning of the brain and spine in human patients. This paramagnetic chelate distributes throughout the extracellular fluid space as dictated by capillary permeability so that abnormal vascularity and sites of blood-CNS barrier breakdown are highlighted. Primary neoplastic disease, metastases, meningeal extension, residual and recurrent tumor have been found to be better distinguished in MR images acquired after administration of GdDTPA. Routine administration of GdDTPA for cranial imaging has resulted in the discovery of otherwise occult lesions in approximately 3 of patients. Although the clinical utility and high therapeutic safety index of the first approved magnetic resonance contrast agent, GdDTPA, have been well established, other contrast agents, having different physical, chemical and biological properties, may offer improved sensitivity and bio-specificity. Agents currently being evaluated in vivo include: low osmolal paramagnetic chelates, superparamagnetic particles, metalloporphyrins, liposome encapsulated agents, perfluorocarbons, intravascular macromolecular chelate complexes and labeled monoclonal antibodies. Concurrent with advances in the development of new compounds, innovations in scanning hardware, pulse sequence design and image post-processing are helping to extend the efficacy of contrast media. Additional clinical experience will indicate which contrast agents and which MR techniques can best facilitate the early detection of specific neoplastic lesions.

  13. Technical Note: Quantitative dynamic contrast-enhanced MRI of a 3-dimensional artificial capillary network.

    Science.gov (United States)

    Gaass, Thomas; Schneider, Moritz Jörg; Dietrich, Olaf; Ingrisch, Michael; Dinkel, Julien

    2017-04-01

    Variability across devices, patients, and time still hinders widespread recognition of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as quantitative biomarker. The purpose of this work was to introduce and characterize a dedicated microchannel phantom as a model for quantitative DCE-MRI measurements. A perfusable, MR-compatible microchannel network was constructed on the basis of sacrificial melt-spun sugar fibers embedded in a block of epoxy resin. Structural analysis was performed on the basis of light microscopy images before DCE-MRI experiments. During dynamic acquisition the capillary network was perfused with a standard contrast agent injection system. Flow-dependency, as well as inter- and intrascanner reproducibility of the computed DCE parameters were evaluated using a 3.0 T whole-body MRI. Semi-quantitative and quantitative flow-related parameters exhibited the expected proportionality to the set flow rate (mean Pearson correlation coefficient: 0.991, P quantitative parameters. All evaluated parameters were well in the range of known in vivo results for the applied flow rates. The constructed phantom enables reproducible, flow-dependent, contrast-enhanced MR measurements with the potential to facilitate standardization and comparability of DCE-MRI examinations. © 2017 American Association of Physicists in Medicine.

  14. Optimal Analysis Method for Dynamic Contrast-Enhanced Diffuse Optical Tomography

    Directory of Open Access Journals (Sweden)

    Michael Ghijsen

    2011-01-01

    Full Text Available Diffuse Optical Tomography (DOT is an optical imaging modality that has various clinical applications. However, the spatial resolution and quantitative accuracy of DOT is poor due to strong photon scatting in biological tissue. Structural a priori information from another high spatial resolution imaging modality such as Magnetic Resonance Imaging (MRI has been demonstrated to significantly improve DOT accuracy. In addition, a contrast agent can be used to obtain differential absorption images of the lesion by using dynamic contrast enhanced DOT (DCE-DOT. This produces a relative absorption map that consists of subtracting a reconstructed baseline image from reconstructed images in which optical contrast is included. In this study, we investigated and compared different reconstruction methods and analysis approaches for regular endogenous DOT and DCE-DOT with and without MR anatomical a priori information for arbitrarily-shaped objects. Our phantom and animal studies have shown that superior image quality and higher accuracy can be achieved using DCE-DOT together with MR structural a priori information. Hence, implementation of a combined MRI-DOT system to image ICG enhancement can potentially be a promising tool for breast cancer imaging.

  15. Contrast-Enhanced Magnetic Resonance Cholangiography: Practical Tips and Clinical Indications for Biliary Disease Management.

    Science.gov (United States)

    Palmucci, Stefano; Roccasalva, Federica; Piccoli, Marina; Fuccio Sanzà, Giovanni; Foti, Pietro Valerio; Ragozzino, Alfonso; Milone, Pietro; Ettorre, Giovanni Carlo

    2017-01-01

    Since its introduction, MRCP has been improved over the years due to the introduction of several technical advances and innovations. It consists of a noninvasive method for biliary tree representation, based on heavily T2-weighted images. Conventionally, its protocol includes two-dimensional single-shot fast spin-echo images, acquired with thin sections or with multiple thick slabs. In recent years, three-dimensional T2-weighted fast-recovery fast spin-echo images have been added to the conventional protocol, increasing the possibility of biliary anatomy demonstration and leading to a significant benefit over conventional 2D imaging. A significant innovation has been reached with the introduction of hepatobiliary contrasts, represented by gadoxetic acid and gadobenate dimeglumine: they are excreted into the bile canaliculi, allowing the opacification of the biliary tree. Recently, 3D interpolated T1-weighted spoiled gradient echo images have been proposed for the evaluation of the biliary tree, obtaining images after hepatobiliary contrast agent administration. Thus, the acquisition of these excretory phases improves the diagnostic capability of conventional MRCP-based on T2 acquisitions. In this paper, technical features of contrast-enhanced magnetic resonance cholangiography are briefly discussed; main diagnostic tips of hepatobiliary phase are showed, emphasizing the benefit of enhanced cholangiography in comparison with conventional MRCP.

  16. Contrast enhancement based on entropy and reflectance analysis for surgical lighting

    Science.gov (United States)

    Shen, Junfei; Wang, Huihui; Wu, Yisi; Li, An; Chen, Chi; Zheng, Zhenrong

    2015-07-01

    Light-emitting diode (LED) is the neotype surgical lighting device as an inexpensive and color-variable illumination. A methodology was designed to value the quality of surgical lighting and used to develop an operation lamp with LEDs enhancing the biological contrast. We assembled a modular array of Phillips LEDs as illumination. In the initial experiment, images of porcine heart were carried out in several LED environments and analyzed quantitatively to assess the function of these LEDs in contrast enhancement. Then we measured the reflectance spectrums of blood, fat and other tissues to obtain the spectral comparison. Based on the result, new illuminations with spectral components which differ most in the comparison was developed. Meanwhile, a new evaluation function combining the entropy analysis and brightness contrast was also built to value the quality of these illuminations. Experiments showed biological features are more visible with treated LED illuminations than the broadband lamps. Thus, the synthesis of LED lighting spectra could be adjusted to provide significant tissue identification. Therefore, we believe the new methodology will contribute to the manufacture of high efficient medical illuminations and act the positive role in coming surgical lighting fields.

  17. Fe Core–Carbon Shell Nanoparticles as Advanced MRI Contrast Enhancer

    Directory of Open Access Journals (Sweden)

    Rakesh P. Chaudhary

    2017-10-01

    Full Text Available The aim of this study is to fabricate a hybrid composite of iron (Fe core–carbon (C shell nanoparticles with enhanced magnetic properties for contrast enhancement in magnetic resonance imaging (MRI. These new classes of magnetic core–shell nanoparticles are synthesized using a one-step top–down approach through the electric plasma discharge generated in the cavitation field in organic solvents by an ultrasonic horn. Transmission electron microscopy (TEM observations revealed the core–shell nanoparticles with 10–85 nm in diameter with excellent dispersibility in water without any agglomeration. TEM showed the structural confirmation of Fe nanoparticles with body centered cubic (bcc crystal structure. Magnetic multi-functional hybrid composites of Fe core–C shell nanoparticles were then evaluated as negative MRI contrast agents, displaying remarkably high transverse relaxivity (r2 of 70 mM−1·S−1 at 7 T. This simple one-step synthesis procedure is highly versatile and produces desired nanoparticles with high efficacy as MRI