WorldWideScience

Sample records for surveillance test intervals

  1. Surveillance test interval optimization

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1995-01-01

    Technical specifications have been developed on the bases of deterministic analyses, engineering judgment, and expert opinion. This paper introduces our risk-based approach to surveillance test interval (STI) optimization. This approach consists of three main levels. The first level is the component level, which serves as a rough estimation of the optimal STI and can be calculated analytically by a differentiating equation for mean unavailability. The second and third levels give more representative results. They take into account the results of probabilistic risk assessment (PRA) calculated by a personal computer (PC) based code and are based on system unavailability at the system level and on core damage frequency at the plant level

  2. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  3. Effects of Forgetting Phenomenon on Surveillance Test Interval

    International Nuclear Information System (INIS)

    Lee, Ho-Joong; Jang, Seung-Cheol

    2007-01-01

    Technical Specifications (TS) requirements for nuclear power plants (NPPs) define Surveillance Requirements (SRs) to assure safety during operation. SRs include surveillance test intervals (STIs) and the optimization of the STIs is one of the main issues in risk-informed applications. Surveillance tests are required in NPPs to detect failures in standby equipment to assure their availability in an accident. However, operating experience of the plants suggests that, in addition to the beneficial effects of detecting latent faults, the tests also may have adverse effects on plant operation or equipment; e.g., plant transient caused by the test and wear-out of safety system equipment due to repeated testing. Recent studies have quantitatively evaluated both the beneficial and adverse effects of testing to decide on an acceptable test interval. The purpose of this research is to investigate the effects of forgetting phenomenon on STI. It is a fundamental human characteristic that a person engaged in a repetitive task will improve his performance over time. The learning phenomenon is observed by the decrease in operation time per unit as operators gain experience by performing additional tasks. However, once there is a break of sufficient length, forgetting starts to take place. In surveillance tests, the most common factor to determine the amount of forgetting is the length of STI, where the longer the STI, the greater the amount of forgetting

  4. Optimization of Allowed Outage Time and Surveillance Test Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun [KEPCO international nuclear graduate school, Ulsan (Korea, Republic of)

    2015-10-15

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  5. Optimization of Allowed Outage Time and Surveillance Test Intervals

    International Nuclear Information System (INIS)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun

    2015-01-01

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  6. Effects of human errors on the determination of surveillance test interval

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Koo, Bon Hyun

    1990-01-01

    This paper incorporates the effects of human error relevant to the periodic test on the unavailability of the safety system as well as the component unavailability. Two types of possible human error during the test are considered. One is the possibility that a good safety system is inadvertently left in a bad state after the test (Type A human error) and the other is the possibility that bad safety system is undetected upon the test (Type B human error). An event tree model is developed for the steady-state unavailability of safety system to determine the effects of human errors on the component unavailability and the test interval. We perform the reliability analysis of safety injection system (SIS) by applying aforementioned two types of human error to safety injection pumps. Results of various sensitivity analyses show that; 1) the appropriate test interval decreases and steady-state unavailability increases as the probabilities of both types of human errors increase, and they are far more sensitive to Type A human error than Type B and 2) the SIS unavailability increases slightly as the probability of Type B human error increases, and significantly as the probability of Type A human error increases. Therefore, to avoid underestimation, the effects of human error should be incorporated in the system reliability analysis which aims at the relaxations of the surveillance test intervals, and Type A human error has more important effect on the unavailability and surveillance test interval

  7. A study on assessment methodology of surveillance test interval and allowed outage time

    International Nuclear Information System (INIS)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol

    1996-07-01

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method

  8. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol [Seoul Nationl Univ., Seoul (Korea, Republic of)] (and others)

    1996-07-15

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method.

  9. A study on assessment methodology of surveillance test interval and Allowed Outage Time

    International Nuclear Information System (INIS)

    Che, Moo Seong; Cheong, Chang Hyeon; Ryu, Yeong Woo; Cho, Jae Seon; Heo, Chang Wook; Kim, Do Hyeong; Kim, Joo Yeol; Kim, Yun Ik; Yang, Hei Chang

    1997-07-01

    Objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. In the second year of this study, the sensitivity analyses about the failure factors of the components are performed in the bases of the assessment methodologies of the first study, the interaction modeling of the STI and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code

  10. A study on assessment methodology of surveillance test interval and Allowed Outage Time

    Energy Technology Data Exchange (ETDEWEB)

    Che, Moo Seong; Cheong, Chang Hyeon; Ryu, Yeong Woo; Cho, Jae Seon; Heo, Chang Wook; Kim, Do Hyeong; Kim, Joo Yeol; Kim, Yun Ik; Yang, Hei Chang [Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-15

    Objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. In the second year of this study, the sensitivity analyses about the failure factors of the components are performed in the bases of the assessment methodologies of the first study, the interaction modeling of the STI and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code.

  11. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hyun; You, Young Woo; Cho, Jae Seon; Huh, Chang Wook; Kim, Do Hyoung; Kim, Ju Youl; Kim, Yoon Ik; Yang, Hui Chang; Park, Kang Min [Seoul National Univ., Seoul (Korea, Republic of)

    1998-03-15

    The objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Internal(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plant safety. In this study, the survey about the assessment methodologies, modelings and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. The sensitivity analyses about the failure factors of the components are performed in the bases of the and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code. The qualitative assessment for the STI/AOR of RPS/ESFAS assured safety the most important system in the nuclear power plant are performed.

  12. Bootstrap confidence intervals and bias correction in the estimation of HIV incidence from surveillance data with testing for recent infection.

    Science.gov (United States)

    Carnegie, Nicole Bohme

    2011-04-15

    The incidence of new infections is a key measure of the status of the HIV epidemic, but accurate measurement of incidence is often constrained by limited data. Karon et al. (Statist. Med. 2008; 27:4617–4633) developed a model to estimate the incidence of HIV infection from surveillance data with biologic testing for recent infection for newly diagnosed cases. This method has been implemented by public health departments across the United States and is behind the new national incidence estimates, which are about 40 per cent higher than previous estimates. We show that the delta method approximation given for the variance of the estimator is incomplete, leading to an inflated variance estimate. This contributes to the generation of overly conservative confidence intervals, potentially obscuring important differences between populations. We demonstrate via simulation that an innovative model-based bootstrap method using the specified model for the infection and surveillance process improves confidence interval coverage and adjusts for the bias in the point estimate. Confidence interval coverage is about 94–97 per cent after correction, compared with 96–99 per cent before. The simulated bias in the estimate of incidence ranges from −6.3 to +14.6 per cent under the original model but is consistently under 1 per cent after correction by the model-based bootstrap. In an application to data from King County, Washington in 2007 we observe correction of 7.2 per cent relative bias in the incidence estimate and a 66 per cent reduction in the width of the 95 per cent confidence interval using this method. We provide open-source software to implement the method that can also be extended for alternate models.

  13. Improving allowed outage time and surveillance test interval requirements: a study of their interactions using probabilistic methods

    International Nuclear Information System (INIS)

    Martorell, S.A.; Serradell, V.G.; Samanta, P.K.

    1995-01-01

    Technical Specifications (TS) define the limits and conditions for operating nuclear plants safely. We selected the Limiting Conditions for Operations (LCO) and Surveillance Requirements (SR), both within TS, as the main items to be evaluated using probabilistic methods. In particular, we focused on the Allowed Outage Time (AOT) and Surveillance Test Interval (STI) requirements in LCO and SR, respectively. Already, significant operating and design experience has accumulated revealing several problems which require modifications in some TS rules. Developments in Probabilistic Safety Assessment (PSA) allow the evaluation of effects due to such modifications in AOT and STI from a risk point of view. Thus, some changes have already been adopted in some plants. However, the combined effect of several changes in AOT and STI, i.e. through their interactions, is not addressed. This paper presents a methodology which encompasses, along with the definition of AOT and STI interactions, the quantification of interactions in terms of risk using PSA methods, an approach for evaluating simultaneous AOT and STI modifications, and an assessment of strategies for giving flexibility to plant operation through simultaneous changes on AOT and STI using trade-off-based risk criteria

  14. Risk-based evaluation of allowed outage time and surveillance test interval extensions for nuclear power plants

    International Nuclear Information System (INIS)

    Gibelli, Sonia Maria Orlando

    2008-03-01

    The main goal of this work is, through the use of Probabilistic Safety Analysis (PSA), to evaluate Technical Specification (TS) Allowed Outage Times (AOT) and Surveillance Test Intervals (STI) extensions for Angra 1 nuclear power plant. PSA has been incorporated as an additional tool, required as part of NPP licensing process. The risk measure used in this work is the Core Damage Frequency (CDF), obtained from the Angra 1 PSA Level 1. AOT and STI extensions are calculated for the Safety Injection System (SIS), Service water System (SAS) and Auxiliary Feedwater System (AFS) through the use of SAPHIRE code. In order to compensate for the risk increase caused by the extensions, compensatory measures as test of redundant train prior to entering maintenance and staggered test strategy are proposed. Results have shown that the proposed AOT extensions are acceptable for the SIS and SAS with the implementation of compensatory measures. The proposed AOT extension is not acceptable for the AFS. The STI extensions are acceptable for all three systems. (author)

  15. Improvement of risk informed surveillance test interval for the safety related instrument and control system of Ulchin units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in UCN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  16. Improvement of risk informed surveillance test interval for the safety related instrumentation and control system of Yonggwang units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in YGN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  17. A Sensitivity Study of Human Errors in Optimizing Surveillance Test Interval (STI) and Allowed Outage Time (AOT) of Standby Safety System

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Shin, Won Ky; You, Young Woo; Yang, Hui Chang

    1998-01-01

    In most cases, the surveillance test intervals (STIs), allowed outage times (AOTS) and testing strategies of safety components in nuclear power plant are prescribed in plant technical specifications. And, in general, it is required that standby safety system shall be redundant (i.e., composed of multiple components) and these components are tested by either staggered test strategy or sequential test strategy. In this study, a linear model is presented to incorporate the effects of human errors associated with test into the evaluation of unavailability. The average unavailabilities of 1/4, 2/4 redundant systems are computed considering human error and testing strategy. The adverse effects of test on system unavailability, such as component wear and test-induced transient have been modelled. The final outcome of this study would be the optimized human error domain from 3-D human error sensitivity analysis by selecting finely classified segment. The results of sensitivity analysis show that the STI and AOT can be optimized provided human error probability is maintained within allowable range. (authors)

  18. Interval algebra: an effective means of scheduling surveillance radar networks

    CSIR Research Space (South Africa)

    Focke, RW

    2015-05-01

    Full Text Available Interval Algebra provides an effective means to schedule surveillance radar networks, as it is a temporal ordering constraint language. Thus it provides a solution to a part of resource management, which is included in the revised Data Fusion...

  19. Interval algebra - an effective means of scheduling surveillance radar networks

    CSIR Research Space (South Africa)

    Focke, RW

    2015-05-01

    Full Text Available Interval Algebra provides an effective means to schedule surveillance radar networks, as it is a temporal ordering constraint language. Thus it provides a solution to a part of resource management, which is included in the revised Data Fusion...

  20. Incidence of Interval Colorectal Cancer Among Inflammatory Bowel Disease Patients Undergoing Regular Colonoscopic Surveillance

    NARCIS (Netherlands)

    Mooiweer, Erik; van der Meulen-de Jong, Andrea E.; Ponsioen, Cyriel Y.; van der Woude, C. Janneke; van Bodegraven, Ad A.; Jansen, Jeroen M.; Mahmmod, Nofel; Kremer, Willemijn; Siersema, Peter D.; Oldenburg, Bas

    2015-01-01

    Surveillance is recommended for patients with long-term inflammatory bowel disease because they have an increased risk of colorectal cancer (CRC). To study the effectiveness of surveillance, we determined the incidence of CRC after negative findings from surveillance colonoscopies (interval CRC). We

  1. Incidence of Interval Colorectal Cancer Among Inflammatory Bowel Disease Patients Undergoing Regular Colonoscopic Surveillance

    NARCIS (Netherlands)

    Mooiweer, Erik; van der Meulen-de Jong, Andrea E.; Ponsioen, Cyriel Y.; van der Woude, C. Janneke; van Bodegraven, Ad A.; Jansen, Jeroen M.; Mahmmod, Nofel; Kremer, Willemijn; Siersema, Peter D.; Oldenburg, Bas

    2015-01-01

    Surveillance is recommended for patients with long-term inflammatory bowel disease because they have an increased risk of colorectal cancer (CRC). To study the effectiveness of surveillance, we determined the incidence of CRC after negative findings from surveillance colonoscopies (interval CRC).

  2. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  3. Existence test for asynchronous interval iterations

    DEFF Research Database (Denmark)

    Madsen, Kaj; Caprani, O.; Stauning, Ole

    1997-01-01

    In the search for regions that contain fixed points ofa real function of several variables, tests based on interval calculationscan be used to establish existence ornon-existence of fixed points in regions that are examined in the course ofthe search. The search can e.g. be performed...... as a synchronous (sequential) interval iteration:In each iteration step all components of the iterate are calculatedbased on the previous iterate. In this case it is straight forward to base simple interval existence and non-existencetests on the calculations done in each step of the iteration. The search can also...... on thecomponentwise calculations done in the course of the iteration. These componentwisetests are useful for parallel implementation of the search, sincethe tests can then be performed local to each processor and only when a test issuccessful do a processor communicate this result to other processors....

  4. Predicting Driver Behavior during the Yellow Interval Using Video Surveillance

    Directory of Open Access Journals (Sweden)

    Juan Li

    2016-12-01

    Full Text Available At a signalized intersection, drivers must make a stop/go decision at the onset of the yellow signal. Incorrect decisions would lead to red light running (RLR violations or crashes. This study aims to predict drivers’ stop/go decisions and RLR violations during yellow intervals. Traffic data such as vehicle approaching speed, acceleration, distance to the intersection, and occurrence of RLR violations are gathered by a Vehicle Data Collection System (VDCS. An enhanced Gaussian Mixture Model (GMM is used to extract moving vehicles from target lanes, and the Kalman Filter (KF algorithm is utilized to acquire vehicle trajectories. The data collected from the VDCS are further analyzed by a sequential logit model, and the relationship between drivers’ stop/go decisions and RLR violations is identified. The results indicate that the distance of vehicles to the stop line at the onset of the yellow signal is an important predictor for both drivers’ stop/go decisions and RLR violations. In addition, vehicle approaching speed is a contributing factor for stop/go decisions. Furthermore, the accelerations of vehicles after the onset of the yellow signal are positively related to RLR violations. The findings of this study can be used to predict the probability of drivers’ RLR violations and improve traffic safety at signalized intersections.

  5. Surveillance test of the JMTR core components

    International Nuclear Information System (INIS)

    Takeda, Takashi; Amezawa, Hiroo; Tobita, Kenji

    1986-02-01

    Surveillance test for the core components of Japan Materials Testing Reactor (JMTR) was started in 1966, and completed in 1985 without one capsule. Most of capsules in the program, except one beryllium specimens, were removed from the core, and carred out the post-irradiation tests at the JMTR Hot Laboratory. The data is applied to review of JMTR core components management plan. JMTR surveillance test was carried out with several kind of materials of JMTR core components, Berylium as the reflector, Hafnium as the neutron absorber of control rod, 17-4PH stainless steel as a roller spring of the control rod, and 304 stainless steel as the grid plate. Results are described in this report. (author)

  6. The relaxation of ESFAS/RPS surveillance test requirements

    International Nuclear Information System (INIS)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse's PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs

  7. The relaxation of ESFAS/RPS surveillance test requirements

    Energy Technology Data Exchange (ETDEWEB)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse`s PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs.

  8. Risk based test interval and maintenance optimisation - Application and uses

    International Nuclear Information System (INIS)

    Sparre, E.

    1999-10-01

    The project is part of an IAEA co-ordinated Research Project (CRP) on 'Development of Methodologies for Optimisation of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs'. The purpose of the project is to investigate the sensitivity of the results obtained when performing risk based optimisation of the technical specifications. Previous projects have shown that complete LPSA models can be created and that these models allow optimisation of technical specifications. However, these optimisations did not include any in depth check of the result sensitivity with regards to methods, model completeness etc. Four different test intervals have been investigated in this study. Aside from an original, nominal, optimisation a set of sensitivity analyses has been performed and the results from these analyses have been compared to the original optimisation. The analyses indicate that the result of an optimisation is rather stable. However, it is not possible to draw any certain conclusions without performing a number of sensitivity analyses. Significant differences in the optimisation result were discovered when analysing an alternative configuration. Also deterministic uncertainties seem to affect the result of an optimisation largely. The sensitivity of failure data uncertainties is important to investigate in detail since the methodology is based on the assumption that the unavailability of a component is dependent on the length of the test interval

  9. Surveillance test of OWL-2 inpile tube

    International Nuclear Information System (INIS)

    Shimizu, Masatsugu; Itoh, Noboru

    1976-08-01

    A series of irradiation surveillance tests performed in integrity evaluation of an inpile tube for the test loop OWL-2 are described. Specimens were exposed to the neutron fluences from 1 x 10 20 to 3.4 x 10 21 n/cm 2 (>1 MeV), and subjected to post-irradiation tensile test at room temperature and service temperature 285 0 C. The strength increased and the ductility decreased with increasing neutron fluence. The reduction in fracture ductility due to neutron irradiation in the fluence range was insignificant, and the elongation of 33% was retained even for the maximum neutron fluence at 285 0 C. Little decrease of the ductility with fluence indicates that the tube would be in service for long time, ie to the integral fluence of 3.4 x 10 21 n/cm 2 . (auth.)

  10. Multi-Camera Persistent Surveillance Test Bed

    National Research Council Canada - National Science Library

    Baran, David; O'Brien, Barry; Fung, Nick; Kovach, Jesse; Miller, David

    2007-01-01

    .... Small reconnaissance surveillance and target acquisition (RSTA) platforms have the ability to cooperate through information sharing to increase the situational awareness over a region of interest (RSTA...

  11. Effects of Training and Feedback on Accuracy of Predicting Rectosigmoid Neoplastic Lesions and Selection of Surveillance Intervals by Endoscopists Performing Optical Diagnosis of Diminutive Polyps.

    Science.gov (United States)

    Vleugels, Jasper L A; Dijkgraaf, Marcel G W; Hazewinkel, Yark; Wanders, Linda K; Fockens, Paul; Dekker, Evelien

    2018-05-01

    Real-time differentiation of diminutive polyps (1-5 mm) during endoscopy could replace histopathology analysis. According to guidelines, implementation of optical diagnosis into routine practice would require it to identify rectosigmoid neoplastic lesions with a negative predictive value (NPV) of more than 90%, using histologic findings as a reference, and agreement with histology-based surveillance intervals for more than 90% of cases. We performed a prospective study with 39 endoscopists accredited to perform colonoscopies on participants with positive results from fecal immunochemical tests in the Bowel Cancer Screening Program at 13 centers in the Netherlands. Endoscopists were trained in optical diagnosis using a validated module (Workgroup serrAted polypS and Polyposis). After meeting predefined performance thresholds in the training program, the endoscopists started a 1-year program (continuation phase) in which they performed narrow band imaging analyses during colonoscopies of participants in the screening program and predicted histological findings with confidence levels. The endoscopists were randomly assigned to groups that received feedback or no feedback on the accuracy of their predictions. Primary outcome measures were endoscopists' abilities to identify rectosigmoid neoplastic lesions (using histology as a reference) with NPVs of 90% or more, and selecting surveillance intervals that agreed with those determined by histology for at least 90% of cases. Of 39 endoscopists initially trained, 27 (69%) completed the training program. During the continuation phase, these 27 endoscopists performed 3144 colonoscopies in which 4504 diminutive polyps were removed. The endoscopists identified neoplastic lesions with a pooled NPV of 90.8% (95% confidence interval 88.6-92.6); their proposed surveillance intervals agreed with those determined by histologic analysis for 95.4% of cases (95% confidence interval 94.0-96.6). Findings did not differ between the group

  12. 2003 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Illness and Injury Prevention Programs

    2007-05-23

    Annual Illness and Injury Surveillance Program report for 2003 for the Nevada Test Site. The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  13. Incidence of Interval Colorectal Cancer Among Inflammatory Bowel Disease Patients Undergoing Regular Colonoscopic Surveillance

    NARCIS (Netherlands)

    Mooiweer, E.; Maulen- de Jong, A.E. van der; Ponsioen, C.Y.; Woude, C.J. van der; Bodegraven, A.A. van; Jansen, J.M.; Mahmmod, N.; Kremer, W.; Siersema, P.D.; Oldenburg, B.

    2015-01-01

    BACKGROUND & AIMS: Surveillance is recommended for patients with long-term inflammatory bowel disease because they have an increased risk of colorectal cancer (CRC). To study the effectiveness of surveillance, we determined the incidence of CRC after negative findings from surveillance colonoscopies

  14. Evaluation of test intervals strategies with a risk monitor

    International Nuclear Information System (INIS)

    Soerman, J.

    2005-01-01

    The Swedish nuclear power utility Oskarshamn Power Group (OKG), is investigating how the use of a risk monitor can facilitate and improve risk-informed decision-making at their nuclear power plants. The intent is to evaluate if risk-informed decision-making can be accepted. A pilot project was initiated and carried out in 2004. The project included investigating if a risk monitor can be used for optimising test intervals for diesel- and gas turbine generators with regard to risk level. The Oskarhamn 2 (O2), PSA Level 1 model was converted into a risk monitor using RiskSpectrum RiskWatcher (RSRW) software. The converted PSA model included the complete PSA model for the power operation mode. RSRW then performs a complete requantification for every analysis. Time dependent reliability data are taken into account, i.e. a shorter test interval will increases the components availability (possibility to e.g. start on demand). The converted O2 model was then used to investigate whether it would be possible to balance longer test intervals for diesel generators, gas turbine generators and high pressure injection system with shorter test intervals for the low pressure injection system, while maintaining a low risk level at the plant. The results show that a new mixture of test intervals can be implemented with only marginally changes in the risk calculated with the risk monitor model. The results indicate that the total number of test activities for the systems included in the pilot study could be reduced by 20% with a maintained level of risk. A risk monitor taking into account the impact from test intervals in availability calculations for components is well suited for evaluation of test interval strategies. It also enables the analyst to evaluate the risk level over a period of time including the impact the actual status of the plant may have on the risk level. (author)

  15. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  16. Parametric change point estimation, testing and confidence interval ...

    African Journals Online (AJOL)

    In many applications like finance, industry and medicine, it is important to consider that the model parameters may undergo changes at unknown moment in time. This paper deals with estimation, testing and confidence interval of a change point for a univariate variable which is assumed to be normally distributed. To detect ...

  17. 46 CFR 57.06-2 - Production test plate interval of testing.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-2 Production test plate interval of testing. (a) At least one... 46 Shipping 2 2010-10-01 2010-10-01 false Production test plate interval of testing. 57.06-2... follows: (1) When the extent of welding on a single vessel exceeds 50 lineal feet of either or both...

  18. Confidence Intervals: From tests of statistical significance to confidence intervals, range hypotheses and substantial effects

    Directory of Open Access Journals (Sweden)

    Dominic Beaulieu-Prévost

    2006-03-01

    Full Text Available For the last 50 years of research in quantitative social sciences, the empirical evaluation of scientific hypotheses has been based on the rejection or not of the null hypothesis. However, more than 300 articles demonstrated that this method was problematic. In summary, null hypothesis testing (NHT is unfalsifiable, its results depend directly on sample size and the null hypothesis is both improbable and not plausible. Consequently, alternatives to NHT such as confidence intervals (CI and measures of effect size are starting to be used in scientific publications. The purpose of this article is, first, to provide the conceptual tools necessary to implement an approach based on confidence intervals, and second, to briefly demonstrate why such an approach is an interesting alternative to an approach based on NHT. As demonstrated in the article, the proposed CI approach avoids most problems related to a NHT approach and can often improve the scientific and contextual relevance of the statistical interpretations by testing range hypotheses instead of a point hypothesis and by defining the minimal value of a substantial effect. The main advantage of such a CI approach is that it replaces the notion of statistical power by an easily interpretable three-value logic (probable presence of a substantial effect, probable absence of a substantial effect and probabilistic undetermination. The demonstration includes a complete example.

  19. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  20. Breast magnetic resonance imaging for surveillance of women with a personal history of breast cancer: outcomes stratified by interval between definitive surgery and surveillance MR imaging.

    Science.gov (United States)

    Park, Vivian Youngjean; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung; Yoon, Jung Hyun

    2018-01-22

    Women with a personal history of breast cancer are at increased risk of future breast cancer events, and may benefit from supplemental screening methods that could enhance early detection of subclinical disease. However, current literature on breast magnetic resonance (MR) imaging surveillance is limited. We investigated outcomes of surveillance breast magnetic resonance (MR) imaging in women with a personal history of breast cancer. We reviewed 1053 consecutive breast MR examinations that were performed for surveillance in 1044 women (median age, 53 years; range, 20-85 years) previously treated for breast cancer between August 2014 and February 2016. All patients had previously received supplemental surveillance with ultrasound. Cancer detection rate (CDR), abnormal interpretation rate and characteristics of MR-detected cancers were assessed, including extramammary cancers. We also calculated the PPV 1 , PPV 3 , sensitivity and specificity for MR-detected intramammary lesions. Performance statistics were stratified by interval following initial surgery. The CDR for MR-detected cancers was 6.7 per 1000 examinations (7 of 1053) and was 3.8 per 1000 examinations (4 of 1053) for intramammary cancers. The overall abnormal interpretation rate was 8.0%, and the abnormal interpretation rate for intramammary lesions was 7.2%. The PPV 1 , PPV 3 , sensitivity and specificity for intramammary lesions was 5.3% (4 of 76), 15.8% (3 of 19), 75.0% (3 of 4) and 98.3% (1031 of 1049), respectively. For MR examinations performed ≤36 months after surgery, the overall CDR was 1.4 per 1000 examinations. For MR examinations performed > 36 months after surgery, the overall CDR was 17.4 per 1000 examinations. Surveillance breast MR imaging may be considered in women with a history of breast cancer, considering the low abnormal interpretation rate and its high specificity. However, the cancer detection rate was low and implementation may be more effective after more than 3

  1. Testing of mobile surveillance robot at a nuclear power plant

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Farnstrom, K.A.

    1987-01-01

    In-plant testing of a mobile surveillance robot (SURBOT) was performed at the Browns Ferry Nuclear Plant by TVA personnel. The results verified that SURBOT can be used for remote surveillance in 54 separate controlled radiation rooms at the plant. High-quality color video, audio, and other data are collected, digitized by an on-board computer, and transmitted through a cable to the control console for real-time display and videotaping. TVA projects that the use of SURBOT for surveillance during plant operation will produce annual savings of about 100 person-rem radiation exposure and $200,000 in operating costs. Based on the successful results of this program, REMOTEC is now commercializing the SURBOT technology on both wheeled and tracked mobile robots for use in nuclear power plants and other hazardous environments

  2. Interval colon cancer in a Lynch syndrome patient under annual colonoscopic surveillance: a case for advanced imaging techniques?

    Directory of Open Access Journals (Sweden)

    Oxentenko Amy S

    2012-05-01

    Full Text Available Abstract Background Lynch syndrome confers increased risk for various malignancies, including colorectal cancer. Colonoscopic surveillance programs have led to reduced incidence of colorectal cancer and reduced mortality from colorectal cancer. Colonoscopy every 1–2 years beginning at age 20–25, or 10 years earlier than the first diagnosis of colorectal cancer in a family, with annual colonoscopy after age 40, is the recommended management for mutation carriers. Screening programs have reduced colon cancer mortality, but interval cancers may occur. Case presentation We describe a 48-year-old woman with Lynch syndrome who was found to have an adenoma with invasive colorectal cancer within one year after a normal colonoscopy. Conclusion Our patient illustrates two current concepts about Lynch syndrome: 1 adenomas are the cancer precursor and 2 such adenomas may be “aggressive,” in the sense that the adenoma progresses more readily and more rapidly to carcinoma in this setting compared to usual colorectal adenomas. Our patient’s resected tumor invaded only into submucosa and all lymph nodes were negative; in that sense, she represents a success for annual colonoscopic surveillance. Still, this case does raise the question of whether advanced imaging techniques are advisable for surveillance colonoscopy in these high-risk patients.

  3. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  4. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  5. Confirmation tests of PWR surveillance capsule shipping container

    International Nuclear Information System (INIS)

    Tomita, N.; Ue, K.; Ohashi, M.; Asada, K.; Yoneda, Y.

    1980-01-01

    Mitsubishi Heavy Industries, Ltd. carried out the confirmation tests to confirm the reliability of the PWR surveillance capsule shipping container and to collect cask design data using a 10-ton weight full scale model at Kobe Shipyard and Engine Works. This report presents the outline of these tests. The B Type container was a cylinder 3289 mm long, 1080 mm in diameter and designed in accordance with the new modified Japanese regulations similar to IAEA regulation. These tests consist of four 9 m drop tests, two 1 m puncture tests, a fire test and an immersion test. In conclusion, safetyness of this container has been proved and various technical data for cask design were also collected through these tests. (author)

  6. Assessing Mediational Models: Testing and Interval Estimation for Indirect Effects.

    Science.gov (United States)

    Biesanz, Jeremy C; Falk, Carl F; Savalei, Victoria

    2010-08-06

    Theoretical models specifying indirect or mediated effects are common in the social sciences. An indirect effect exists when an independent variable's influence on the dependent variable is mediated through an intervening variable. Classic approaches to assessing such mediational hypotheses ( Baron & Kenny, 1986 ; Sobel, 1982 ) have in recent years been supplemented by computationally intensive methods such as bootstrapping, the distribution of the product methods, and hierarchical Bayesian Markov chain Monte Carlo (MCMC) methods. These different approaches for assessing mediation are illustrated using data from Dunn, Biesanz, Human, and Finn (2007). However, little is known about how these methods perform relative to each other, particularly in more challenging situations, such as with data that are incomplete and/or nonnormal. This article presents an extensive Monte Carlo simulation evaluating a host of approaches for assessing mediation. We examine Type I error rates, power, and coverage. We study normal and nonnormal data as well as complete and incomplete data. In addition, we adapt a method, recently proposed in statistical literature, that does not rely on confidence intervals (CIs) to test the null hypothesis of no indirect effect. The results suggest that the new inferential method-the partial posterior p value-slightly outperforms existing ones in terms of maintaining Type I error rates while maximizing power, especially with incomplete data. Among confidence interval approaches, the bias-corrected accelerated (BC a ) bootstrapping approach often has inflated Type I error rates and inconsistent coverage and is not recommended; In contrast, the bootstrapped percentile confidence interval and the hierarchical Bayesian MCMC method perform best overall, maintaining Type I error rates, exhibiting reasonable power, and producing stable and accurate coverage rates.

  7. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  8. The technology development for surveillance test of reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Sun Phil; Park, Day Young; Choi, Kwen Jai

    1997-12-01

    Benchmark test was performed in accordance with the requirement of US NRC Reg. Guide DG-1053 for Kori unit-1 in order to determine best-estimated fast neutron fluence irradiated into reactor vessel. Since the uncertainty of radiation analysis comes from the calculation error due to neutron cross-section data, reactor core geometrical dimension, core source, mesh density, angular expansion and convergence criteria, evaluation of calculational uncertainty due to analytical method was performed in accordance with the regulatory guide and the proof was performed for entire analysis by comparing the measurement value obtained by neutron dosimetry located in surveillance capsule. Best-estimated neutron fluence in reactor vessel was calculated by bias factor, neutron flux measurement value/calculational value, from reanalysis result from previous 1st through 4th surveillance testing and finally fluence prediction was performed for the end of reactor life and the entire period of plant life extension. Pressurized thermal shock analysis was performed in accordance with 10 CFR 50.61 using the result of neutron fluence analysis in order to predict the life of reactor vessel material and the criteria of safe operation for Kori unit 1 was reestablished. (author). 55 refs., 55 figs.

  9. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  10. Optimal Testing Intervals in the Squatting Test to Determine Baroreflex Sensitivity

    OpenAIRE

    Ishitsuka, S.; Kusuyama, N.; Tanaka, M.

    2014-01-01

    The recently introduced “squatting test” (ST) utilizes a simple postural change to perturb the blood pressure and to assess baroreflex sensitivity (BRS). In our study, we estimated the reproducibility of and the optimal testing interval between the STs in healthy volunteers. Thirty-four subjects free of cardiovascular disorders and taking no medication were instructed to perform the repeated ST at 30-sec, 1-min, and 3-min intervals in duplicate in a random sequence, while the systolic blood p...

  11. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  12. Transitioning from antenatal surveillance surveys to routine HIV testing: a turning point in the mother-to-child transmission prevention programme for HIV surveillance in Brazil.

    Science.gov (United States)

    Pereira, Gerson Fernando Mendes; Sabidó, Meritxell; Caruso, Alessandro; Benzaken, Adele Schwartz

    2017-07-05

    In Brazil, due to the rapid increase in programmes for the prevention of mother-to-child transmission (PMTCT), routine programme data are widely available. The objective of this study was to assess the utility of programmatic data to replace HIV surveillance based on the antenatal care (ANC) surveillance survey (SS). We analysed ANC SS data from 219 maternity service clinics. PMTCT variables were extracted from the ANC SS data collection form, which allowed us to capture and compare the ANC SS data and PMTCT HIV test results for each pregnant woman who completed the ANC SS. Both the PMTCT programme and the ANC SS tested for HIV using sequential ELISA and western blot for confirmation. We assessed the completeness (% missing) of the PMTC data included in the ANC SS. Of the 36,713 pregnant women who had ANC SS HIV tests performed, 30,588 also underwent PMTCT HIV testing. The HIV prevalence rate from routine PMTCT testing was 0.36%, compared to 0.38% from the ANC SS testing (relative difference -0.05%; absolute difference -0.02%). The relative difference in prevalence rates between pregnant women in northern Brazil and pregnant women central-west Brazil was -0.98 and 0.66, respectively. Of the 29,856 women who had HIV test results from both the PMTCT and ANC SS, the positive percent agreement of the PMTCT versus the surveillance test was 84.1% (95% confidence interval [CI]: 74.8-91.0), and the negative percent agreement was 99.9% (95% CI: 99.9-100.0). The PMTCT HIV testing uptake was 86.4%. The ANC SS HIV prevalence was 0.33% among PMTCT non-refusers and 0.59% among refusers, with a percent bias of -10.80% and a differential prevalence ratio of 0.56. Syphilis and HIV testing results were complete in 98% and 97.6% of PMTCT reports, respectively. The reported HIV status for the women at clinic entry was missing. Although there were consistent HIV prevalence estimates from the PMTCT data and the ANC SS, the overall positive percent agreement of 84.1% falls below the

  13. Establishment, test and evaluation of a prototype volcano surveillance system

    Science.gov (United States)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  14. Occupational health surveillance: Pulmonary function testing in emergency responders

    Directory of Open Access Journals (Sweden)

    James D McCluskey

    2014-01-01

    Full Text Available Emergency responders may be exposed to a variety of fumes, gases, and particulates during the course of their job that can affect pulmonary function (PF and require the use of respiratory protection. This investigation used occupational health monitoring examination data to characterize PF in a population currently employed as emergency responders. PF tests for workers who required health examinations to ensure fitness for continued respirator use were compared to the National Health and Nutrition Examination Survey (NHANES III Raw Spirometry database to determine if decreased PF was associated with employment as an emergency responder. The results of this research indicated that the emergency responders experienced a modest, but statistically significant, increase in forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC mean values over the NHANES III population in both total and stratified analyses, including stratification by age, gender, height, and smoking history. Results are likely due to a combination of effectively controlled exposures in the workplace, and the healthy worker effect among long-term workers. PF testing required by the Occupational and Safety Health Administration (OSHA has substantial utility for conducting occupational surveillance at the population level. In this investigation, we were able to quickly evaluate if abnormal PF existed in an industrial sector known to have exposures that, when uncontrolled, can lead to PF impairment.

  15. Bayes Factor Approaches for Testing Interval Null Hypotheses

    NARCIS (Netherlands)

    Morey, Richard D.; Rouder, Jeffrey N.

    2011-01-01

    Psychological theories are statements of constraint. The role of hypothesis testing in psychology is to test whether specific theoretical constraints hold in data. Bayesian statistics is well suited to the task of finding supporting evidence for constraint, because it allows for comparing evidence

  16. The technology development for surveillance test of RPV materials 2

    International Nuclear Information System (INIS)

    Chang, Kee Ok; Lee, Sam Lai; Kim, Byoung Chul; Choi, Sun Pil; Choi, Kwen Jai

    1998-12-01

    Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of 2.4 x 10 1 9n/cm 2 (E≥1.0 MeV) in a typical pressurized water reactor environment at about 288 deg C. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen Noise(BN) amplitude, coercivity, maximum induction were measured for magnetic parameters, respectively. Results of mechanical property measurements showed an increase in yield and tensil strength, microvickers hardness 41J indexed RT NDT and a decrease in upper shelf energy irrespective of base and weld metals. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude, BN energy have dropped significantly but coercivity has increased rapidly after irradiation. For isothermally heat treated condition of irradiated specimen, BN energy has increased while Vickers microhardness has decreased. Results of BNE and Vickers microhardness are reversed to the results on irradiated condition. All these consistent changes in magnetic parameter and Vickers microhardness measurement, which are thought to be resulted from the interaction between irradiation-induced defects and dislocation, and magnetic domain, respectively, show a possibility that magnetic measurement may be used to the evaluation of material degradation and recovery due to neutron irradiation and heat treatment, respectively, if a relevant large database is prepared. (author). 49 refs., 7 tabs., 23 figs

  17. 2007 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-06-30

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  18. 2006 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2008-04-24

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of illness and injury surveillance activities that provide an early warning system to detect health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence, occupational injuries and illnesses, and disabilities and deaths among current workers.

  19. 2008 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-10-05

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  20. Can we ease the financial burden of colonoscopy? Using real-time endoscopic assessment of polyp histology to predict surveillance intervals.

    Science.gov (United States)

    Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M

    2015-12-01

    Polyps identified at colonoscopy are predominantly diminutive (1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.

  1. Optimal test intervals for shutdown systems for the Cernavoda nuclear power station

    International Nuclear Information System (INIS)

    Negut, Gh.; Laslau, F.

    1993-01-01

    Cernavoda nuclear power station required a complete PSA study. As a part of this study, an important goal to enhance the effectiveness of the plant operation is to establish optimal test intervals for the important engineering safety systems. The paper presents, briefly, the current methods to optimize the test intervals. For this reason it was used Vesely methods to establish optimal test intervals and Frantic code to survey the influence of the test intervals on system availability. The applications were done on the Shutdown System no. 1, a shutdown system provided whit solid rods and on Shutdown System no. 2 provided with injecting poison. The shutdown systems receive nine total independent scram signals that dictate the test interval. Fault trees for the both safety systems were developed. For the fault tree solutions an original code developed in our Institute was used. The results, intended to be implemented in the technical specifications for test and operation of Cernavoda NPS are presented

  2. Binomial confidence intervals for testing non-inferiority or superiority: a practitioner's dilemma.

    Science.gov (United States)

    Pradhan, Vivek; Evans, John C; Banerjee, Tathagata

    2016-08-01

    In testing for non-inferiority or superiority in a single arm study, the confidence interval of a single binomial proportion is frequently used. A number of such intervals are proposed in the literature and implemented in standard software packages. Unfortunately, use of different intervals leads to conflicting conclusions. Practitioners thus face a serious dilemma in deciding which one to depend on. Is there a way to resolve this dilemma? We address this question by investigating the performances of ten commonly used intervals of a single binomial proportion, in the light of two criteria, viz., coverage and expected length of the interval. © The Author(s) 2013.

  3. A Methodology for Evaluation of Inservice Test Intervals for Pumps and Motor Operated Valves

    International Nuclear Information System (INIS)

    McElhaney, K.L.

    1999-01-01

    The nuclear industry has begun efforts to reevaluate inservice tests (ISTs) for key components such as pumps and valves. At issue are two important questions--What kinds of tests provide the most meaningful information about component health, and what periodic test intervals are appropriate? In the past, requirements for component testing were prescribed by the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. The tests and test intervals specified in the Code were generic in nature and test intervals were relatively short. Operating experience has shown, however, that performance and safety improvements and cost savings could be realized by tailoring IST programs to similar components with comparable safety importance and service conditions. In many cases, test intervals may be lengthened, resulting in cost savings for utilities and their customers

  4. Results from an Interval Management (IM) Flight Test and Its Potential Benefit to Air Traffic Management Operations

    Science.gov (United States)

    Baxley, Brian; Swieringa, Kurt; Berckefeldt, Rick; Boyle, Dan

    2017-01-01

    NASA's first Air Traffic Management Technology Demonstration (ATD-1) subproject successfully completed a 19-day flight test of an Interval Management (IM) avionics prototype. The prototype was built based on IM standards, integrated into two test aircraft, and then flown in real-world conditions to determine if the goals of improving aircraft efficiency and airport throughput during high-density arrival operations could be met. The ATD-1 concept of operation integrates advanced arrival scheduling, controller decision support tools, and the IM avionics to enable multiple time-based arrival streams into a high-density terminal airspace. IM contributes by calculating airspeeds that enable an aircraft to achieve a spacing interval behind the preceding aircraft. The IM avionics uses its data (route of flight, position, etc.) and Automatic Dependent Surveillance-Broadcast (ADS-B) state data from the Target aircraft to calculate this airspeed. The flight test demonstrated that the IM avionics prototype met the spacing accuracy design goal for three of the four IM operation types tested. The primary issue requiring attention for future IM work is the high rate of IM speed commands and speed reversals. In total, during this flight test, the IM avionics prototype showed significant promise in contributing to the goals of improving aircraft efficiency and airport throughput.

  5. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  6. Optimal test intervals of standby components based on actual plant-specific data

    International Nuclear Information System (INIS)

    Jones, R.B.; Bickel, J.H.

    1987-01-01

    Based on standard reliability analysis techniques, both under testing and over testing affect the availability of standby components. If tests are performed too often, unavailability is increased since the equipment is being used excessively. Conversely if testing is performed too infrequently, the likelihood of component unavailability is also increased due to the formation of rust, heat or radiation damage, dirt infiltration, etc. Thus from a physical perspective, an optimal test interval should exist which minimizes unavailability. This paper illustrates the application of an unavailability model that calculates optimal testing intervals for components with a failure database. (orig./HSCH)

  7. Basic data for surveillance test on core support graphite structures for the high temperature engineering test reactor (HTTR)

    International Nuclear Information System (INIS)

    Sumita, Junya; Shibata, Taiju; Kikuchi, Takayuki; Iyoku, Tatsuo; Fujimoto, Nozomu; Ishihara, Masahiro; Sawa, Kazuhiro

    2007-02-01

    Both of the visual inspection by a TV camera and the measurement of material properties by surveillance test on core support graphite structures are planned for the High Temperature Engineering Test Reactor (HTTR) to confirm their structural integrity and characteristics. The surveillance test is aimed to investigate the change of material properties by aging effects such as fast neutron irradiation and oxidation. The obtained data will be used not only for evaluating the structural integrity of the core support graphite structures of the HTTR but also for design of advanced Very High Temperature Reactor (VHTR) discussed at generation IV international forum. This report describes the initial material properties of surveillance specimens before installation and installed position of surveillance specimens in the HTTR. (author)

  8. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  9. Solar Alpha Rotary Joint (SARJ) Lubrication Interval Test and Evaluation (LITE). Post-Test Grease Analysis

    Science.gov (United States)

    Golden, Johnny L.; Martinez, James E.; Devivar, Rodrigo V.

    2015-01-01

    The Solar Alpha Rotary Joint (SARJ) is a mechanism of the International Space Station (ISS) that orients the solar power generating arrays toward the sun as the ISS orbits our planet. The orientation with the sun must be maintained to fully charge the ISS batteries and maintain all the other ISS electrical systems operating properly. In 2007, just a few months after full deployment, the starboard SARJ developed anomalies that warranted a full investigation including ISS Extravehicular Activity (EVA). The EVA uncovered unexpected debris that was due to degradation of a nitride layer on the SARJ bearing race. ISS personnel identified the failure root-cause and applied an aerospace grease to lubricate the area associated with the anomaly. The corrective action allowed the starboard SARJ to continue operating within the specified engineering parameters. The SARJ LITE (Lubrication Interval Test and Evaluation) program was initiated by NASA, Lockheed Martin, and Boeing to simulate the operation of the ISS SARJ for an extended time. The hardware was designed to test and evaluate the exact material components used aboard the ISS SARJ, but in a controlled area where engineers could continuously monitor the performance. After running the SARJ LITE test for an equivalent of 36+ years of continuous use, the test was opened to evaluate the metallography and lubrication. We have sampled the SARJ LITE rollers and plate to fully assess the grease used for lubrication. Chemical and thermal analysis of these samples has generated information that has allowed us to assess the location, migration, and current condition of the grease. The collective information will be key toward understanding and circumventing any performance deviations involving the ISS SARJ in the years to come.

  10. Analysis of unavailability related to demand failures as a function of the testing interval

    International Nuclear Information System (INIS)

    Carretero, J.A.; Pereira, M.B.; Perez Lobo, E.M.

    1998-01-01

    The unavailability related to the demand failure of a component is the sum of the contributions of the failures in demand and in waiting. An important point in PSAs is the calculation of unavailabilities of the basic events of demand failure. Several criteria are used for this, with the objective of simplifying said quantification. The information available from two nuclear power plants has been analysed, in order to determine the tendency in the models in demand and in waiting, as a function of the test intervals, the following conclusions were obtained: - There is a clear tendency for the possibility of failure in demand to increase as the interval between tests increases - The test intervals considered in PSAs are not always coherent with the estimates of real demand; this implies a penalty when using the in waiting model, due to the underlying conservatism Therefore, increasing the intervals between tests over time (a tendency studied in nuclear power plants)could cause demand due to tests to b e significantly less than that due to real actuations. This implies a need to apply test intervals based on historic demands and not on those due to historic tests, in order to avoid conservatism. (Author)

  11. Incidence of interval cancers in faecal immunochemical test colorectal screening programmes in Italy.

    Science.gov (United States)

    Giorgi Rossi, Paolo; Carretta, Elisa; Mangone, Lucia; Baracco, Susanna; Serraino, Diego; Zorzi, Manuel

    2018-03-01

    Objective In Italy, colorectal screening programmes using the faecal immunochemical test from ages 50 to 69 every two years have been in place since 2005. We aimed to measure the incidence of interval cancers in the two years after a negative faecal immunochemical test, and compare this with the pre-screening incidence of colorectal cancer. Methods Using data on colorectal cancers diagnosed in Italy from 2000 to 2008 collected by cancer registries in areas with active screening programmes, we identified cases that occurred within 24 months of negative screening tests. We used the number of tests with a negative result as a denominator, grouped by age and sex. Proportional incidence was calculated for the first and second year after screening. Results Among 579,176 and 226,738 persons with negative test results followed up at 12 and 24 months, respectively, we identified 100 interval cancers in the first year and 70 in the second year. The proportional incidence was 13% (95% confidence interval 10-15) and 23% (95% confidence interval 18-25), respectively. The estimate for the two-year incidence is 18%, which was slightly higher in females (22%; 95% confidence interval 17-26), and for proximal colon (22%; 95% confidence interval 16-28). Conclusion The incidence of interval cancers in the two years after a negative faecal immunochemical test in routine population-based colorectal cancer screening was less than one-fifth of the expected incidence. This is direct evidence that the faecal immunochemical test-based screening programme protocol has high sensitivity for cancers that will become symptomatic.

  12. Conditional dependence between tests affects the diagnosis and surveillance of animal diseases

    DEFF Research Database (Denmark)

    Gardner, I.A.; Stryhn, Henrik; Lind, Peter

    2000-01-01

    Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel te...... for toxoplasmosis and brucellosis in swine, and Johne's disease in cattle to illustrate calculation methods and to indicate the likely magnitude of the dependence between serologic tests used for diagnosis and surveillance of animal diseases....

  13. Reactor safety impact of functional test intervals: an application of Bayesian decision theory

    International Nuclear Information System (INIS)

    Buoni, F.B.

    1978-01-01

    Functional test intervals for important nuclear reactor systems can be obtained by viewing safety assessment as a decision process and functional testing as a Bayesian learning or information process. A preposterior analysis is used as the analytical model to find the preposterior expected reliability of a system as a function of test intervals. Persistent and transitory failure models are shown to yield different results. Functional tests of systems subject to persistent failure are effective in maintaining system reliability goals. Functional testing is not effective for systems subject to transitory failure; preventive maintenance must be used. A Bayesian posterior analysis of testing data can discriminate between persistent and transitory failure. The role of functional testing is seen to be an aid in assessing the future performance of reactor systems

  14. Testing independence of bivariate interval-censored data using modified Kendall's tau statistic.

    Science.gov (United States)

    Kim, Yuneung; Lim, Johan; Park, DoHwan

    2015-11-01

    In this paper, we study a nonparametric procedure to test independence of bivariate interval censored data; for both current status data (case 1 interval-censored data) and case 2 interval-censored data. To do it, we propose a score-based modification of the Kendall's tau statistic for bivariate interval-censored data. Our modification defines the Kendall's tau statistic with expected numbers of concordant and disconcordant pairs of data. The performance of the modified approach is illustrated by simulation studies and application to the AIDS study. We compare our method to alternative approaches such as the two-stage estimation method by Sun et al. (Scandinavian Journal of Statistics, 2006) and the multiple imputation method by Betensky and Finkelstein (Statistics in Medicine, 1999b). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Browns Ferry Nuclear Plant: variation in test intervals for high-pressure coolant injection (HPCI) system

    International Nuclear Information System (INIS)

    Christie, R.F.; Stetkar, J.W.

    1985-01-01

    The change in availability of the high-pressure coolant injection system (HPCIS) due to a change in pump and valve test interval from monthly to quarterly was analyzed. This analysis started by using the HPCIS base line evaluation produced as part of the Browns Ferry Nuclear Plant (BFN) Probabilistic Risk Assessment (PRA). The base line evaluation showed that the dominant contributors to the unavailability of the HPCI system are hardware failures and the resultant downtime for unscheduled maintenance. The effect of changing the pump and valve test interval from monthly to quarterly was analyzed by considering the system unavailability due to hardware failures, the unavailability due to testing, and the unavailability due to human errors that potentially could occur during testing. The magnitude of the changes in unavailability affected by the change in test interval are discussed. The analysis showed a small increase in the availability of the HPCIS to respond to loss of coolant accidents (LOCAs) and a small decrease in the availability of the HPCIS to respond to transients which require HPCIS actuation. In summary, the increase in test interval from monthly to quarterly does not significantly impact the overall HPCIS availability

  16. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  17. Environmental surveillance report for the Nevada Test Site (January 1981 through December 1981)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1982-05-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1981 through December 1981. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  18. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance

    NARCIS (Netherlands)

    Murphy, S.C.; Hermsen, C.C.; Douglas, A.D.; Edwards, N.J.; Petersen, I.; Fahle, G.A.; Adams, M.; Berry, A.A.; Billman, Z.P.; Gilbert, S.C.; Laurens, M.B.; Leroy, O.; Lyke, K.E.; Plowe, C.V.; Seilie, A.M.; Strauss, K.A.; Teelen, K.; Hill, A.V.; Sauerwein, R.W.

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal

  19. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  20. Integration of HIV testing in tuberculosis drug resistance surveillance in Kazakhstan and Kenya

    NARCIS (Netherlands)

    Klinkenberg, E.; van den Hof, S.; Tursynbayeva, A.; Kipruto, H.; Wahogo, J.; Pak, S.; Kutwa, A.; L'Herminez, R.

    2012-01-01

    In Kenya and Kazakhstan, integration of human immunodeficiency virus (HIV) testing results into the routine surveillance of multidrug-resistant tuberculosis (MDR-TB) proved feasible and useful. The integration process improved overall data quality and data validation capacity, and integrated data

  1. Environmental-surveillance report for the Nevada Test Site (January 1982 through December 1982)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1983-06-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted from January 1982 through December 1982. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG's) is established

  2. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  3. Environmental surveillance report for the Nevada Test Site (January 1980-December 1980)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1981-01-01

    Results are presented for the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1980 through December 1980. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  4. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  6. Hypothesis Testing of Inclusion of the Tolerance Interval for the Assessment of Food Safety.

    Directory of Open Access Journals (Sweden)

    Hungyen Chen

    Full Text Available In the testing of food quality and safety, we contrast the contents of the newly proposed food (genetically modified food against those of conventional foods. Because the contents vary largely between crop varieties and production environments, we propose a two-sample test of substantial equivalence that examines the inclusion of the tolerance intervals of the two populations, the population of the contents of the proposed food, which we call the target population, and the population of the contents of the conventional food, which we call the reference population. Rejection of the test hypothesis guarantees that the contents of the proposed foods essentially do not include outliers in the population of the contents of the conventional food. The existing tolerance interval (TI0 is constructed to have at least a pre-specified level of the coverage probability. Here, we newly introduce the complementary tolerance interval (TI1 that is guaranteed to have at most a pre-specified level of the coverage probability. By applying TI0 and TI1 to the samples from the target population and the reference population respectively, we construct a test statistic for testing inclusion of the two tolerance intervals. To examine the performance of the testing procedure, we conducted a simulation that reflects the effects of gene and environment, and residual from a crop experiment. As a case study, we applied the hypothesis testing to test if the distribution of the protein content of rice in Kyushu area is included in the distribution of the protein content in the other areas in Japan.

  7. Automated reactivity anomaly surveillance in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.; Honeyman, D.J.; Shook, A.T.; Krohn, C.N.

    1985-01-01

    The automated technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and, thus, provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state

  8. Surveillance tests for light-water cooled nuclear power reactor vessels in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong-Sun; Ahn, Sang-Bok; Park, Dae-Gyu; Jung, Yang-Hong; Yoo, Byung-Ok; Oh, Wan-Ho; Baik, Seung-Je; Koo, Dae-Seo; Lee, Key-Soon

    1999-01-01

    The surveillance tests for light-water cooled nuclear power reactor vessels were established to monitor the radiation-induced changes in the mechanical properties of ferritic materials in the beltline according to US NRC 10 CFR 50 App. G, US NRC RG1.99-rev.2, ASTM E185-82 and E185-94 in Irradiated Materials Examination Facility(IMEF). The surveillance capsule was transported from NPPs pool sites to KAERI IMEF by using a shipping cask. The capsule was cut and dismantled by capsule cutting machine and milling machine in M2 hot cell. Charpy tests and tension tests were performed in M5a and M5b hot cells respectively. Especially the EPMA located at hot lab was used to analyze the Ni and Cu wt% composition of base metal and weld for predicting the adjusted reference temperature(ART). The established process and test results were summarized in this paper. (author)

  9. Long-term maintenance of immediate or delayed extinction is determined by the extinction-test interval

    OpenAIRE

    Johnson, Justin S.; Escobar, Martha; Kimble, Whitney L.

    2010-01-01

    Short acquisition-extinction intervals (immediate extinction) can lead to either more or less spontaneous recovery than long acquisition-extinction intervals (delayed extinction). Using rat subjects, we observed less spontaneous recovery following immediate than delayed extinction (Experiment 1). However, this was the case only if a relatively long extinction-test interval was used; a relatively short extinction-test interval yielded the opposite result (Experiment 2). Previous data appear co...

  10. Test interval optimization of safety systems of nuclear power plant using fuzzy-genetic approach

    International Nuclear Information System (INIS)

    Durga Rao, K.; Gopika, V.; Kushwaha, H.S.; Verma, A.K.; Srividya, A.

    2007-01-01

    Probabilistic safety assessment (PSA) is the most effective and efficient tool for safety and risk management in nuclear power plants (NPP). PSA studies not only evaluate risk/safety of systems but also their results are very useful in safe, economical and effective design and operation of NPPs. The latter application is popularly known as 'Risk-Informed Decision Making'. Evaluation of technical specifications is one such important application of Risk-Informed decision making. Deciding test interval (TI), one of the important technical specifications, with the given resources and risk effectiveness is an optimization problem. Uncertainty is inherently present in the availability parameters such as failure rate and repair time due to the limitation in assessing these parameters precisely. This paper presents a solution to test interval optimization problem with uncertain parameters in the model with fuzzy-genetic approach along with a case of application from a safety system of Indian pressurized heavy water reactor (PHWR)

  11. Evaluation of HFIR vessel surveillance data and hydro-test conditions

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Nanstad, R.K.

    1994-01-01

    Surveillance specimens for the High Flux Isotope Reactor (HFIR) pressure vessel were removed and tested during 1993, after the vessel had accumulated 701,469 MWd of operation. The data agree well with HFIR surveillance data obtained in previous years. In conjunction with this effort, the vessel hydro-test conditions were reevaluated and found to be more than adequate. In view of this result, and because there are economic incentives for reducing the frequency of hydro testing, an analysis was performed to determine the minimum permissible frequency. The value obtained is substantially less than that presently specified. It was also determined that a somewhat lower cooling-tower-basin temperature is acceptable (improves operational flexibility). In 1986, after ∼20 years of reactor operation, it was discovered that the vessel embrittlement rate was substantially greater than expected. Possible reasons for the accelerated rate are reviewed in this report

  12. Development and interval testing of a naturalistic driving methodology to evaluate driving behavior in clinical research.

    Science.gov (United States)

    Babulal, Ganesh M; Addison, Aaron; Ghoshal, Nupur; Stout, Sarah H; Vernon, Elizabeth K; Sellan, Mark; Roe, Catherine M

    2016-01-01

    Background : The number of older adults in the United States will double by 2056. Additionally, the number of licensed drivers will increase along with extended driving-life expectancy. Motor vehicle crashes are a leading cause of injury and death in older adults. Alzheimer's disease (AD) also negatively impacts driving ability and increases crash risk. Conventional methods to evaluate driving ability are limited in predicting decline among older adults. Innovations in GPS hardware and software can monitor driving behavior in the actual environments people drive in. Commercial off-the-shelf (COTS) devices are affordable, easy to install and capture large volumes of data in real-time. However, adapting these methodologies for research can be challenging. This study sought to adapt a COTS device and determine an interval that produced accurate data on the actual route driven for use in future studies involving older adults with and without AD.  Methods : Three subjects drove a single course in different vehicles at different intervals (30, 60 and 120 seconds), at different times of day, morning (9:00-11:59AM), afternoon (2:00-5:00PM) and night (7:00-10pm). The nine datasets were examined to determine the optimal collection interval. Results : Compared to the 120-second and 60-second intervals, the 30-second interval was optimal in capturing the actual route driven along with the lowest number of incorrect paths and affordability weighing considerations for data storage and curation. Discussion : Use of COTS devices offers minimal installation efforts, unobtrusive monitoring and discreet data extraction.  However, these devices require strict protocols and controlled testing for adoption into research paradigms.  After reliability and validity testing, these devices may provide valuable insight into daily driving behaviors and intraindividual change over time for populations of older adults with and without AD.  Data can be aggregated over time to look at changes

  13. Tests and Confidence Intervals for an Extended Variance Component Using the Modified Likelihood Ratio Statistic

    DEFF Research Database (Denmark)

    Christensen, Ole Fredslund; Frydenberg, Morten; Jensen, Jens Ledet

    2005-01-01

    The large deviation modified likelihood ratio statistic is studied for testing a variance component equal to a specified value. Formulas are presented in the general balanced case, whereas in the unbalanced case only the one-way random effects model is studied. Simulation studies are presented......, showing that the normal approximation to the large deviation modified likelihood ratio statistic gives confidence intervals for variance components with coverage probabilities very close to the nominal confidence coefficient....

  14. A Methodology for Evaluation of Inservice Test Intervals for Pumps and Motor-Operated Valves

    International Nuclear Information System (INIS)

    Cox, D.F.; Haynes, H.D.; McElhaney, K.L.; Otaduy, P.J.; Staunton, R.H.; Vesely, W.E.

    1999-01-01

    Recent nuclear industry reevaluation of component inservice testing (IST) requirements is resulting in requests for IST interval extensions and changes to traditional IST programs. To evaluate these requests, long-term component performance and the methods for mitigating degradation need to be understood. Determining the appropriate IST intervals, along with component testing, monitoring, trending, and maintenance effects, has become necessary. This study provides guidelines to support the evaluation of IST intervals for pumps and motor-operated valves (MOVs). It presents specific engineering information pertinent to the performance and monitoring/testing of pumps and MOVs, provides an analytical methodology for assessing the bounding effects of aging on component margin behavior, and identifies basic elements of an overall program to help ensure component operability. Guidance for assessing probabilistic methods and the risk importance and safety consequences of the performance of pumps and MOVs has not been specifically included within the scope of this report, but these elements may be included in licensee change requests

  15. A Note on Confidence Interval for the Power of the One Sample Test

    OpenAIRE

    A. Wong

    2010-01-01

    In introductory statistics texts, the power of the test of a one-sample mean when the variance is known is widely discussed. However, when the variance is unknown, the power of the Student's -test is seldom mentioned. In this note, a general methodology for obtaining inference concerning a scalar parameter of interest of any exponential family model is proposed. The method is then applied to the one-sample mean problem with unknown variance to obtain a ( 1 − ) 100% confidence interval for...

  16. Application of advanced irradiation analysis methods to light water reactor pressure vessel test and surveillance programs

    International Nuclear Information System (INIS)

    Odette, R.; Dudey, N.; McElroy, W.; Wullaert, R.; Fabry, A.

    1977-01-01

    Inaccurate characterization and inappropriate application of neutron irradiation exposure variables contribute a substantial amount of uncertainty to embrittlement analysis of light water reactor pressure vessels. Damage analysis involves characterization of the irradiation environment (dosimetry), correlation of test and surveillance metallurgical and dosimetry data, and projection of such data to service conditions. Errors in available test and surveillance dosimetry data are estimated to contribute a factor of approximately 2 to the data scatter. Non-physical (empirical) correlation procedures and the need to extrapolate to the vessel may add further error. Substantial reductions in these uncertainties in future programs can be obtained from a more complete application of available damage analysis tools which have been developed for the fast reactor program. An approach to reducing embrittlement analysis errors is described, and specific examples of potential applications are given. The approach is based on damage analysis techniques validated and calibrated in benchmark environments

  17. Decomposing the interaction between retention interval and study/test practice: the role of retrievability.

    Science.gov (United States)

    Jang, Yoonhee; Wixted, John T; Pecher, Diane; Zeelenberg, René; Huber, David E

    2012-01-01

    Even without feedback, test practice enhances delayed performance compared to study practice, but the size of the effect is variable across studies. We investigated the benefit of testing, separating initially retrievable items from initially nonretrievable items. In two experiments, an initial test determined item retrievability. Retrievable or nonretrievable items were subsequently presented for repeated study or test practice. Collapsing across items, in Experiment 1, we obtained the typical cross-over interaction between retention interval and practice type. For retrievable items, however, the cross-over interaction was quantitatively different, with a small study benefit for an immediate test and a larger testing benefit after a delay. For nonretrievable items, there was a large study benefit for an immediate test, but one week later there was no difference between the study and test practice conditions. In Experiment 2, initially nonretrievable items were given additional study followed by either an immediate test or even more additional study, and one week later performance did not differ between the two conditions. These results indicate that the effect size of study/test practice is due to the relative contribution of retrievable and nonretrievable items.

  18. A Note on Confidence Interval for the Power of the One Sample Test

    Directory of Open Access Journals (Sweden)

    A. Wong

    2010-01-01

    Full Text Available In introductory statistics texts, the power of the test of a one-sample mean when the variance is known is widely discussed. However, when the variance is unknown, the power of the Student's -test is seldom mentioned. In this note, a general methodology for obtaining inference concerning a scalar parameter of interest of any exponential family model is proposed. The method is then applied to the one-sample mean problem with unknown variance to obtain a (1−100% confidence interval for the power of the Student's -test that detects the difference (−0. The calculations require only the density and the cumulative distribution functions of the standard normal distribution. In addition, the methodology presented can also be applied to determine the required sample size when the effect size and the power of a size test of mean are given.

  19. Test Statistics and Confidence Intervals to Establish Noninferiority between Treatments with Ordinal Categorical Data.

    Science.gov (United States)

    Zhang, Fanghong; Miyaoka, Etsuo; Huang, Fuping; Tanaka, Yutaka

    2015-01-01

    The problem for establishing noninferiority is discussed between a new treatment and a standard (control) treatment with ordinal categorical data. A measure of treatment effect is used and a method of specifying noninferiority margin for the measure is provided. Two Z-type test statistics are proposed where the estimation of variance is constructed under the shifted null hypothesis using U-statistics. Furthermore, the confidence interval and the sample size formula are given based on the proposed test statistics. The proposed procedure is applied to a dataset from a clinical trial. A simulation study is conducted to compare the performance of the proposed test statistics with that of the existing ones, and the results show that the proposed test statistics are better in terms of the deviation from nominal level and the power.

  20. Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

    Science.gov (United States)

    Shi, Xiangyun; Kuang, Yang; Makroglou, Athena; Mokshagundam, Sriprakash; Li, Jiaxu

    2017-11-01

    Type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index.

  1. A Comparative Risk Assessment of Extended Integrated Leak Rate Testing Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji Yong; Hwang, Seok Won; Lee, Byung Sik [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2009-10-15

    This paper presents the risk impacts of extending the Integrated Leak Rate Testing (ILRT) intervals (from five years to ten years) of Yonggwang (YGN) Unit 1 and 2. These risk impacts depended on the annual variances of meteorological data and resident population. Main comparisons were performed between the initial risk assessment (2005) for the purpose of extending ILRT interval and risk reassessment (2009) where the changed plant internal configurations (core inventory and radioisotope release fraction) and plant external alterations (wind directions, rainfall and population distributions) were monitored. The reassessment showed that there was imperceptible risk increase when the ILRT interval was extended compared to the initial risk assessment. In addition, the increased value of the Large Early Release Frequency (LERF) also satisfied the acceptance guideline proposed on Reg. Guide 1.174. The MACCS II code was used for evaluating the offsite consequence analysis. The primary risk index were used as the Probabilistic Population Dose (PPD) by considering the early effects within 80 km. The Probabilistic Safety Assessment (PSA) of YGN 1 and 2 was applied to evaluate the accident frequency of each source term category and the used PSA scope was limited to internal event.

  2. Integrity assessment of TAPS reactor pressure vessel at extended EOL using surveillance test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah, Priti Kotak

    2008-05-01

    Integrity assessment of pressure vessels of nuclear reactors (RPV) primarily concentrates on the prevention of brittle failure and conditions are defined under which brittle failure can be excluded. Accordingly, two approaches based on Transition Temperature Concept and Fracture Mechanics Concept were adopted using the impact test results of three credible surveillance data sets obtained from the surveillance specimens of Tarapur Atomic Power Station. RT NDT data towards end of life (EOL) were estimated from the impact test results in accordance with the procedures of USNRC Regulatory Guide 1.99, Rev. 2 and were used as primary input for assessment of the vessel integrity. SA302B (nickel modified) steel cladded with stainless steel is used as the pressure vessel material for the two 210 MWe boiling water reactors of the Tarapur Atomic Power Station (TAPS). The reactors were commissioned during the year 1969. The chemical compositions of SA302B (modified) steel used in fabricating the vessel and the specified tensile property and the Charpy impact property requirements of the steel broadly meet ASME specified requirements. Therefore, the pressure temperature limit curves prescribed by General Electric (G.E.) were compared with those as obtained using procedures of ASME Section XII, Appendix G. The tensile and the Charpy impact properties at 60 EFPY of vessel operation as derived from the surveillance specimens even fulfilled the specified requirements for the virgin material of ASME. Integrity assessment carried out using the two approaches indicated the safety of the vessel for continued operation up to 60 EFPY. (author)

  3. Prognostic value of QTc interval dispersion changes during exercise testing in hypertensive men

    Directory of Open Access Journals (Sweden)

    Đorđević Dragan

    2008-01-01

    Full Text Available INTRODUCTION The prognostic significance of QTc dispersion changes during exercise testing (ET in patients with left ventricular hypertrophy is not clear. OBJECTIVE The aim was to study the dynamics of QTc interval dispersion (QTcd in patients (pts with left ventricular hypertrophy (LVH during the exercise testing and its prognostic significance. METHOD In the study we included 55 men (aged 53 years with hypertensive left ventricular hypertrophy and a negative ET (LVH group, 20 men (aged 58 years with a positive ET and 20 healthy men (aged 55 years. There was no statistically significant difference in the left ventricular mass index (LVMI between LVH group and ILVH group (160.9±14.9 g/m2 and 152.8±22.7 g/m2. The first ECG was done before the ET and the second one was done during the first minute of recovery, with calculation of QTc dispersion. The patients were followed during five years for new cardiovascular events. RESULTS During the ET, the QTcd significantly increased in LVH group (56.8±18.0 - 76.7±22.6 ms; p<0.001. A statistically significant correlation was found between the amount of ST segment depression at the end of ET and QTc dispersion at the beginning and at the end of ET (r=0.673 and r=0.698; p<0.01. The QTc dispersion was increased in 35 (63.6% patients and decreased in 20 (36.4% patients during the ET. Three patients (5.4% in the first group had adverse cardiovascular events during the five-year follow-up. A multiple stepwise regression model was formed by including age, LVMI, QTc interval, QTc dispersion and change of QTc dispersion during the ET. There was no prognostic significance of QTc interval and QTc dispersion during five-year follow-up in regard to adverse cardiovascular events, but prognostic value was found for LVMI (coefficient β=0.480; p<0.001. CONCLUSION The increase of QTc interval dispersion is common in men with positive ET for myocardial ischemia and there is a correlation between QTc dispersion and

  4. Trimester specific reference intervals for thyroid function tests in normal Indian pregnant women.

    Science.gov (United States)

    Sekhri, Tarun; Juhi, Juhi Agarwal; Wilfred, Reena; Kanwar, Ratnesh S; Sethi, Jyoti; Bhadra, Kuntal; Nair, Sirimavo; Singh, Satveer

    2016-01-01

    Accurate assessment of thyroid function during pregnancy is critical, for initiation of thyroid hormone therapy, as well as for adjustment of thyroid hormone dose in hypothyroid cases. We evaluated pregnant women who had no past history of thyroid disorders and studied their thyroid function in each trimester. 86 normal pregnant women in the first trimester of pregnancy were selected for setting reference intervals. All were healthy, euthyroid and negative for thyroid peroxidase antibody (TPOAb). These women were serially followed throughout pregnancy. 124 normal nonpregnant subjects were selected for comparison. Thyrotropin (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and anti-TPO were measured using Roche Elecsys 1010 analyzer. Urinary iodine content was determined by simple microplate method. The 2.5th and 97.5th percentiles were calculated as the reference intervals for thyroid hormone levels during each trimester. SPSS (version 14.0, SPSS Inc., Chicago, IL, USA) was used for data processing and analysis. The reference intervals for the first, second and third trimesters for the following parameters: TSH 0.09-6.65, 0.51-6.66, 0.91-4.86 µIU/mL, FT4 9.81-18.53, 8.52-19.43, 7.39-18.28 pM/L and FT3 3.1-6.35, 2.39-5.12, 2.57-5.68 pM/L respectively. Thyroid hormone concentrations significantly differed during pregnancy at different stages of gestation. The pregnant women in the study had median urinary iodine concentration of 150-200 µg/l during each trimester. The trimester-specific reference intervals for thyroid tests during pregnancy have been established for pregnant Indian women serially followed during pregnancy using 2.5th and 97.5th percentiles.

  5. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    Full Text Available Abstract Background von Hippel-Lindau (VHL disease is a hereditary cancer syndrome caused by germline mutations in the VHL gene. Patients have significant morbidity and mortality secondary to vascular tumors. Disease management is centered on tumor surveillance that allows early detection and treatment. Presymptomatic genetic testing is therefore recommended, including in at-risk children. Methods We tested 17 families (n = 109 individuals for VHL mutations including 43 children under the age of 18. Personalized genetic counseling was provided pre and post-test and the individuals undergoing presymptomatic testing filled out questionnaires gathering socio-demographic, psychological and psychiatric data. Mutation analysis was performed by direct sequencing of the VHL gene. Mutation-carriers were screened for VHL disease-related tumors and were offered follow-up annual examinations. Results Mutations were identified in 36 patients, 17 of whom were asymptomatic. In the initial screening, we identified at least one tumor in five of 17 previously asymptomatic individuals. At the end of five years, only 38.9% of the mutation-carriers continued participating in our tumor surveillance program. During this time, 14 mutation carriers developed a total of 32 new tumors, three of whom died of complications. Gender, education, income, marital status and religiosity were not found to be associated with adherence to the surveillance protocol. Follow-up adherence was also independent of pre-test depression, severity of disease, or number of affected family members. The only statistically significant predictor of adherence was being symptomatic at the time of testing (OR = 5; 95% CI 1.2 - 20.3; p = 0.02. Pre-test anxiety was more commonly observed in patients that discontinued follow-up (64.7% vs. 35.3%; p = 0.01. Conclusions The high initial uptake rate of genetic testing for VHL disease, including in minors, allowed the discontinuation of unnecessary screening

  6. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christie, B.

    1996-12-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. {open_quotes}Conditional Probabilities{close_quotes} of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps.

  7. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    International Nuclear Information System (INIS)

    Christie, B.

    1996-01-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. open-quotes Conditional Probabilitiesclose quotes of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps

  8. The 5th surveillance testing for Kori unit 1 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed primarily by Korea Atomic Energy Research Institute and Westinhouse corporation partially involved in testing and calculation data evaluation in order to obtain reliable test result. Fast neutron fluences for capsule V, T, S, R and P were 5.087E+18, 1.115E+19, 1.228E+19, 2.988E+19, and 3.938E+19n/cm2, respectively. The bias factor, the ratio of calculation/measurement, was 0.940 for the 1st through 5th testing and the calculational uncertainty, 7% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.9846E+19n/cm{sup 2} based on the end of 17th fuel cycle and it was predicted that the fluences of vessel inside surface at 24, 32, 40 and 48EFPY would reach 3.0593E+19, 4.0695E+19, 5.0797E+19 and 6.0900E+19n/cm{sup 2} based on the current calculation. PTS analysis for Kori unit 1 showed that 27.93EFPY was the threshold value for 300 deg F requirement. 71 refs., 33 figs., 52 tabs. (Author)

  9. Learned helplessness: effects of response requirement and interval between treatment and testing.

    Science.gov (United States)

    Hunziker, M H L; Dos Santos, C V

    2007-11-01

    Three experiments investigated learned helplessness in rats manipulating response requirements, shock duration, and intervals between treatment and testing. In Experiment 1, rats previously exposed to uncontrollable or no shocks were tested under one of four different contingencies of negative reinforcement: FR 1 or FR 2 escape contingency for running, and FR1 escape contingency for jumping (differing for the maximum shock duration of 10s or 30s). The results showed that the uncontrollable shocks produced a clear operant learning deficit (learned helplessness effect) only when the animals were tested under the jumping FR 1 escape contingency with 10-s max shock duration. Experiment 2 isolated of the effects of uncontrollability from shock exposure per se and showed that the escape deficit observed using the FR 1 escape jumping response (10-s shock duration) was produced by the uncontrollability of shock. Experiment 3 showed that using the FR 1 jumping escape contingency in the test, the learned helplessness effect was observed one, 14 or 28 days after treatment. These results suggest that running may not be an appropriate test for learned helplessness, and that many diverging results found in the literature might be accounted for by the confounding effects of respondent and operant contingencies present when running is required of rats.

  10. PCA-based bootstrap confidence interval tests for gene-disease association involving multiple SNPs

    Directory of Open Access Journals (Sweden)

    Xue Fuzhong

    2010-01-01

    Full Text Available Abstract Background Genetic association study is currently the primary vehicle for identification and characterization of disease-predisposing variant(s which usually involves multiple single-nucleotide polymorphisms (SNPs available. However, SNP-wise association tests raise concerns over multiple testing. Haplotype-based methods have the advantage of being able to account for correlations between neighbouring SNPs, yet assuming Hardy-Weinberg equilibrium (HWE and potentially large number degrees of freedom can harm its statistical power and robustness. Approaches based on principal component analysis (PCA are preferable in this regard but their performance varies with methods of extracting principal components (PCs. Results PCA-based bootstrap confidence interval test (PCA-BCIT, which directly uses the PC scores to assess gene-disease association, was developed and evaluated for three ways of extracting PCs, i.e., cases only(CAES, controls only(COES and cases and controls combined(CES. Extraction of PCs with COES is preferred to that with CAES and CES. Performance of the test was examined via simulations as well as analyses on data of rheumatoid arthritis and heroin addiction, which maintains nominal level under null hypothesis and showed comparable performance with permutation test. Conclusions PCA-BCIT is a valid and powerful method for assessing gene-disease association involving multiple SNPs.

  11. The Effect of Retention Interval Task Difficulty on Young Children's Prospective Memory: Testing the Intention Monitoring Hypothesis

    Science.gov (United States)

    Mahy, Caitlin E. V.; Moses, Louis J.

    2015-01-01

    The current study examined the impact of retention interval task difficulty on 4- and 5-year-olds' prospective memory (PM) to test the hypothesis that children periodically monitor their intentions during the retention interval and that disrupting this monitoring may result in poorer PM performance. In addition, relations among PM, working memory,…

  12. Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.

    Directory of Open Access Journals (Sweden)

    Joseph R Egger

    Full Text Available BACKGROUND: Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time. METHODS AND FINDINGS: Using HIV antibody screening test data from New York City STD clinics, we developed a formal, statistical method of prospectively detecting temporal clusters of poor performance of a screening test. From 2005 to 2008, New York City, as well as other states, observed unexpectedly high false-positive (FP rates in an oral fluid-based rapid test used for screening HIV. We attempted to formally assess whether the performance of this HIV screening test statistically deviated from both local expectation and the manufacturer's claim for the test. Results indicate that there were two significant temporal clusters in the FP rate of the oral HIV test, both of which exceeded the manufacturer's upper limit of the 95% CI for the product. Furthermore, the FP rate of the test varied significantly by both STD clinic and test lot, though not by test operator. CONCLUSIONS: Continuous monitoring of surveillance data has the benefit of providing information regarding test performance, and if conducted in real-time, it can enable programs to examine reasons for poor test performance in close proximity to the occurrence. Techniques used in this study could be a valuable addition for postmarketing surveillance of test performance and may become particularly important with the increase in rapid testing methods.

  13. QTc interval prolongation in children with Turner syndrome: the results of exercise testing and 24-h ECG.

    Science.gov (United States)

    Dalla Pozza, Robert; Bechtold, Susanne; Urschel, Simon; Netz, Heinrich; Schwarz, Hans-Peter

    2009-01-01

    Turner syndrome (TS) is the most common sex chromosome abnormality in females. Recently, a prolongation of the rate-corrected QT (QTc) interval in the electrocardiogram (ECG) of TS patients has been reported. A prolonged QTc interval has been correlated to an increased risk for sudden cardiac death, and medical treatment is warranted in patients with congenital long QT syndrome (LQTS). Additionally, several drugs of common use are contraindicated in LQTS because of their effects on myocardial repolarization. The importance of the QTc prolongation in TS patients is not known at present. Eighteen TS patients with a prolonged QTc interval (group 1) and 11 TS patients with a normal QTc interval (group 2) (mean age 12.6+/-3.1 vs. 11.8+/-2.1 years, respectively) were tested. The QTc interval was calculated during exercise testing and during 24-h ECG recordings. None of the patients experienced adverse cardiac events during the tests. The mean QTc interval decreased from 0.467 to 0.432 s in group 1 and from 0.432 to 0.412 s in group 2. During the 24-h ECG, the maximum QTc interval was significantly prolonged in group 1 (0.51 vs. 0.465 s, pinformation about the cardiac risk in the single TS patient with a prolonged QTc interval. This helps in counseling these girls, as clear therapeutic guidelines are currently lacking.

  14. Final report : mobile surveillance and wireless communication systems field operational test. Volume 1, Executive summary

    Science.gov (United States)

    1999-03-01

    This study focused on assessing the application of traffic monitoring and management systems which use transportable surveillance and ramp meter trailers, video image processors, and wireless communications. The mobile surveillance and wireless commu...

  15. A retrospective study of owner-requested testing as surveillance for equine infectious anemia in Canada (2009-2012).

    Science.gov (United States)

    Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L

    2017-12-01

    This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.

  16. HIV test offers and acceptance: New York State findings from the behavioral risk factor surveillance system and the National HIV behavioral surveillance, 2011-2012.

    Science.gov (United States)

    John Leung, Shu-Yin; Sinclair, Amber H; Battles, Haven B; Swain, Carol-Ann E; French, Patrick Tyler; Anderson, Bridget J; Sowizral, Mycroft J; Ruberto, Rachael; Brissette, Ian; Lillquist, Patricia; Smith, Lou C

    2015-01-01

    The New York State HIV testing law requires that patients aged 13-64 years be offered HIV testing in health care settings. We investigated the extent to which HIV testing was offered and accepted during the 24 months after law enactment. We added local questions to the Behavioral Risk Factor Surveillance System (BRFSS) and the National HIV Behavioral Surveillance (NHBS) surveys asking respondents aged 18-64 years whether they were offered an HIV test in health care settings, and whether they had accepted testing. Statewide prevalence estimates of test offers and acceptance were obtained from a combined 2011-2012 BRFSS sample (N = 6,223). Local estimates for 2 high-risk populations were obtained from NHBS 2011 men who have sex with men (N = 329) and 2012 injection drug users (N = 188) samples. BRFSS data showed that 73% of New Yorkers received care in any health care setting in the past 12 months, of whom 25% were offered an HIV test. Sixty percent accepted the test when offered. The levels of test offer increased from 20% to 29% over time, whereas acceptance levels decreased from 68% to 53%. NHBS data showed that 81% of men who have sex with men received care, of whom 43% were offered an HIV test. Eighty-eight percent accepted the test when offered. Eighty-five percent of injection drug users received care, of whom 63% were offered an HIV test, and 63% accepted the test when offered. We found evidence of partial and increasing implementation of the HIV testing law. Importantly, these studies demonstrated New Yorkers' willingness to accept an offered HIV test as part of routine care in health care settings.

  17. Reliability of case definitions for public health surveillance assessed by Round-Robin test methodology

    Directory of Open Access Journals (Sweden)

    Claus Hermann

    2006-05-01

    Full Text Available Abstract Background Case definitions have been recognized to be important elements of public health surveillance systems. They are to assure comparability and consistency of surveillance data and have crucial impact on the sensitivity and the positive predictive value of a surveillance system. The reliability of case definitions has rarely been investigated systematically. Methods We conducted a Round-Robin test by asking all 425 local health departments (LHD and the 16 state health departments (SHD in Germany to classify a selection of 68 case examples using case definitions. By multivariate analysis we investigated factors linked to classification agreement with a gold standard, which was defined by an expert panel. Results A total of 7870 classifications were done by 396 LHD (93% and all SHD. Reporting sensitivity was 90.0%, positive predictive value 76.6%. Polio case examples had the lowest reporting precision, salmonellosis case examples the highest (OR = 0.008; CI: 0.005–0.013. Case definitions with a check-list format of clinical criteria resulted in higher reporting precision than case definitions with a narrative description (OR = 3.08; CI: 2.47–3.83. Reporting precision was higher among SHD compared to LHD (OR = 1.52; CI: 1.14–2.02. Conclusion Our findings led to a systematic revision of the German case definitions and build the basis for general recommendations for the creation of case definitions. These include, among others, that testable yes/no criteria in a check-list format is likely to improve reliability, and that software used for data transmission should be designed in strict accordance with the case definitions. The findings of this study are largely applicable to case definitions in many other countries or international networks as they share the same structural and editorial characteristics of the case definitions evaluated in this study before their revision.

  18. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  19. Environmental surveillance and research at the Nevada Test Site: The beginning and the rationale

    International Nuclear Information System (INIS)

    Elle, D.R.; Church, B.W.; Bingham, F.E.

    1990-01-01

    Concurrently with the first nuclear-weapons tests at the Nevada Test Site (NTS) in 1951, an environmental surveillance and monitoring program was established offsite. Initial emphasis was on tracking fallout clouds and measuring external radiation exposure rates. An environmental research program was also initiated. Establishment of comprehensive programs has facilitated the ability to address issues such as the inventory and distribution of radionuclides in surface soils, reconstruction of offsite population doses, and recognition of areas requiring additional information. We have learned that a successful environmental monitoring program must be flexible and responsive to change; must address public as well as technical and regulatory concerns; and results must be continuously interpreted to ensure that all pathways are considered and the programs are proactive in their approach

  20. The 4th surveillance testing for Kori unit 3 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-10-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 4.983E+18, 1.641E+19, 3.158E+19, and 4.469E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.840 for the 1st through 4th testing and the calculational uncertainty, 12% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.362E+19n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.481E+19, 4.209E+19, 5.144E+19 and 5.974E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 41 tabs. (Author)

  1. The 5th surveillance testing for Kori unit 2 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-03-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules V, R, P, T and N are 2.837E+18, 1.105E+19, 2.110E+19, 3.705E+19 and 4.831E+19n/cm{sup 2}, respectively. The bias factor, the ratio of measurement/calculation, was 0.918 for the 1st through 5th testing and the calculational uncertainty, 11.6% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.898E+19n/cm{sup 2} based on the end of 15th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 4.203E+19, 5.232E+19, 6.262E+19 and 7.291E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 49 refs., 35 figs., 48 tabs. (Author)

  2. A labelled discrete choice experiment adds realism to the choices presented: preferences for surveillance tests for Barrett esophagus

    Directory of Open Access Journals (Sweden)

    Donkers Bas

    2009-05-01

    Full Text Available Abstract Background Discrete choice experiments (DCEs allow systematic assessment of preferences by asking respondents to choose between scenarios. We conducted a labelled discrete choice experiment with realistic choices to investigate patients' trade-offs between the expected health gains and the burden of testing in surveillance of Barrett esophagus (BE. Methods Fifteen choice scenarios were selected based on 2 attributes: 1 type of test (endoscopy and two less burdensome fictitious tests, 2 frequency of surveillance. Each test-frequency combination was associated with its own realistic decrease in risk of dying from esophageal adenocarcinoma. A conditional logit model was fitted. Results Of 297 eligible patients (155 BE and 142 with non-specific upper GI symptoms, 247 completed the questionnaire (84%. Patients preferred surveillance to no surveillance. Current surveillance schemes of once every 1–2 years were amongst the most preferred alternatives. Higher health gains were preferred over those with lower health gains, except when test frequencies exceeded once a year. For similar health gains, patients preferred video-capsule over saliva swab and least preferred endoscopy. Conclusion This first example of a labelled DCE using realistic scenarios in a healthcare context shows that such experiments are feasible. A comparison of labelled and unlabelled designs taking into account setting and research question is recommended.

  3. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyeong Geun; Kim, Min Chul; Yoon, Ji Hyun; Lee, Bong Sang; Lim, Sang Yeob; Kwon, Jun Hyun [Nuclear Materials Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant’s lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

  5. Confidence intervals permit, but don't guarantee, better inference than statistical significance testing

    Directory of Open Access Journals (Sweden)

    Melissa Coulson

    2010-07-01

    Full Text Available A statistically significant result, and a non-significant result may differ little, although significance status may tempt an interpretation of difference. Two studies are reported that compared interpretation of such results presented using null hypothesis significance testing (NHST, or confidence intervals (CIs. Authors of articles published in psychology, behavioural neuroscience, and medical journals were asked, via email, to interpret two fictitious studies that found similar results, one statistically significant, and the other non-significant. Responses from 330 authors varied greatly, but interpretation was generally poor, whether results were presented as CIs or using NHST. However, when interpreting CIs respondents who mentioned NHST were 60% likely to conclude, unjustifiably, the two results conflicted, whereas those who interpreted CIs without reference to NHST were 95% likely to conclude, justifiably, the two results were consistent. Findings were generally similar for all three disciplines. An email survey of academic psychologists confirmed that CIs elicit better interpretations if NHST is not invoked. Improved statistical inference can result from encouragement of meta-analytic thinking and use of CIs but, for full benefit, such highly desirable statistical reform requires also that researchers interpret CIs without recourse to NHST.

  6. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Science.gov (United States)

    Murphy, Sean C; Hermsen, Cornelus C; Douglas, Alexander D; Edwards, Nick J; Petersen, Ines; Fahle, Gary A; Adams, Matthew; Berry, Andrea A; Billman, Zachary P; Gilbert, Sarah C; Laurens, Matthew B; Leroy, Odile; Lyke, Kristen E; Plowe, Christopher V; Seilie, Annette M; Strauss, Kathleen A; Teelen, Karina; Hill, Adrian V S; Sauerwein, Robert W

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA) program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  7. A strategy for determination of test intervals of k-out-of-n multi-channel systems

    International Nuclear Information System (INIS)

    Cho, S.; Jiang, J.

    2007-01-01

    State space models for determination of the optimal test frequencies for k-out-of-n multi channel systems are developed in this paper. The analytic solutions for the optimal surveillance test frequencies are derived using the Markov process technique. The solutions show that an optimal test frequency which maximizes the target probability can be determined by decomposing the system states to 3 states based on the system configuration and success criteria. Examples of quantification of the state probabilities and the optimal test frequencies of a three-channel system and a four-channel system with different success criteria are presented. The strategy for finding the optimal test frequency developed in this paper can generally be applicable to any k-out-of-n multi-channel standby systems that involve complex testing schemes. (author)

  8. Genotyping using whole-genome sequencing is a realistic alternative to surveillance based on phenotypic antimicrobial susceptibility testing

    DEFF Research Database (Denmark)

    Zankari, Ea; Hasman, Henrik; Kaas, Rolf Sommer

    2013-01-01

    -genome sequencing (WGS) may soon be within reach even for routine surveillance and clinical diagnostics. The aim of this study was to evaluate WGS as a routine tool for surveillance of antimicrobial resistance compared with current phenotypic procedures. Methods: Antimicrobial susceptibility tests were performed...... to the categorizing of isolates as resistant and 2569 as susceptible. Seven cases of disagreement between tested and predicted susceptibility were observed, six of which were related to spectinomycin resistance in Escherichia coli. Correlation between MLST type and resistance profiles was only observed in Salmonella...

  9. A study on the optimization of test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing approach

    International Nuclear Information System (INIS)

    Kang, D. I.; Kim, K. Y.; Yang, Z. A.; Ha, J. J.

    2002-01-01

    We optimized the test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing (IST) approach. First, we categorized the IST check valves for Ulchin Unit 3 according to their contributions to the safety of Ulchin Unit 3. Next, we performed the risk analysis on the relaxation of test interval for check valves identified as relatively low important to the safety of Ulchin Unit 3 to identify the maximum increasable test interval of them. Finally, we estimated the number of tests of IST check valves to be performed due to the changes of test interval. These study results are as follows: The categorization of IST check valve importance; the number of the HSSCs is 24(11.48%), the ISSCs is 40 (19.14%), and the LSSCs is 462(69.38%). The maximum increasable test interval; 6 times of current test interval of ISSCs2 and 40 times of that of LSSCs. The number of tests of IST check valves to be performed during 6 refueling time can be reduced from 7692 to 1333 ( 82.7%)

  10. Extended result reading window in lateral flow tests detecting exposure to Onchocerca volvulus: a new technology to improve epidemiological surveillance tools.

    Directory of Open Access Journals (Sweden)

    Allison Golden

    Full Text Available Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov. An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%-92.0%, and specificity of 97% (95% confidence interval: 95.4%-98.6%. Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives. We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96. We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test.

  11. Constrained optimization of test intervals using a steady-state genetic algorithm

    International Nuclear Information System (INIS)

    Martorell, S.; Carlos, S.; Sanchez, A.; Serradell, V.

    2000-01-01

    There is a growing interest from both the regulatory authorities and the nuclear industry to stimulate the use of Probabilistic Risk Analysis (PRA) for risk-informed applications at Nuclear Power Plants (NPPs). Nowadays, special attention is being paid on analyzing plant-specific changes to Test Intervals (TIs) within the Technical Specifications (TSs) of NPPs and it seems to be a consensus on the need of making these requirements more risk-effective and less costly. Resource versus risk-control effectiveness principles formally enters in optimization problems. This paper presents an approach for using the PRA models in conducting the constrained optimization of TIs based on a steady-state genetic algorithm (SSGA) where the cost or the burden is to be minimized while the risk or performance is constrained to be at a given level, or vice versa. The paper encompasses first with the problem formulation, where the objective function and constraints that apply in the constrained optimization of TIs based on risk and cost models at system level are derived. Next, the foundation of the optimizer is given, which is derived by customizing a SSGA in order to allow optimizing TIs under constraints. Also, a case study is performed using this approach, which shows the benefits of adopting both PRA models and genetic algorithms, in particular for the constrained optimization of TIs, although it is also expected a great benefit of using this approach to solve other engineering optimization problems. However, care must be taken in using genetic algorithms in constrained optimization problems as it is concluded in this paper

  12. Quality specifications for the extra-analytical phase of laboratory testing: Reference intervals and decision limits.

    Science.gov (United States)

    Ceriotti, Ferruccio

    2017-07-01

    Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Gait in children with cerebral palsy : observer reliability of Physician Rating Scale and Edinburgh Visual Gait Analysis Interval Testing scale

    NARCIS (Netherlands)

    Maathuis, KGB; van der Schans, CP; van Iperen, A; Rietman, HS; Geertzen, JHB

    2005-01-01

    The aim of this study was to test the inter- and intra-observer reliability of the Physician Rating Scale (PRS) and the Edinburgh Visual Gait Analysis Interval Testing (GAIT) scale for use in children with cerebral palsy (CP). Both assessment scales are quantitative observational scales, evaluating

  14. Schistosomiasis in Scottish travellers: public health importance of laboratory testing and the need for enhanced surveillance.

    Science.gov (United States)

    Alexander, Claire L; Cottom, Laura; Smith, Kitty; Perrow, Kali; Coyne, Michael; Jones, Brian L

    2018-03-01

    Imported schistosomiasis is of significant public health importance and is likely to be underestimated since infection is often asymptomatic. We describe data from travellers residing in Scotland which includes a subset of group travellers from one of the largest Health Boards in Scotland. Clotted bloods were obtained during the period 2001-15 from a total of 8163 Scottish travellers. This included seven groups comprising of 182 travellers. Sera were examined for the presence of Schistosome species antibody at the Scottish Parasite Diagnostic and Reference Laboratory (SPDRL). Of all, 25% (n = 1623) tested positive with 40% (n = 651) of those patients aged between 20 and 24 years. Although 62% (n = 1006) of those who tested positive reported travel to Africa, important information on the specific region visited was lacking in almost one-third of samples received. Overall, 62 (34%) of group travellers tested positive and 95% (n = 59) reporting travel to Africa. Globalization, affordable air travel and improved awareness, are likely to contribute towards the increasing number of imported schistosomiasis cases. Therefore, enhanced surveillance capturing detailed travel history and fresh water exposures will improve risk stratification, pre-travel advice and optimize testing and treatment regimes for this increasingly important parasitic disease.

  15. Exploring the Benefits of Molecular Testing for Gonorrhoea Antibiotic Resistance Surveillance in Remote Settings.

    Directory of Open Access Journals (Sweden)

    Ben B Hui

    Full Text Available Surveillance for gonorrhoea antimicrobial resistance (AMR is compromised by a move away from culture-based testing in favour of more convenient nucleic acid amplification test (NAAT tests. We assessed the potential benefit of a molecular resistance test in terms of the timeliness of detection of gonorrhoea AMR.An individual-based mathematical model was developed to describe the transmission of gonorrhoea in a remote Indigenous population in Australia. We estimated the impact of the molecular test on the time delay between first importation and the first confirmation that the prevalence of gonorrhoea AMR (resistance proportion has breached the WHO-recommended 5% threshold (when a change in antibiotic should occur. In the remote setting evaluated in this study, the model predicts that when culture is the only available means of testing for AMR, the breach will only be detected when the actual prevalence of AMR in the population has already reached 8 - 18%, with an associated delay of ~43 - 69 months between first importation and detection. With the addition of a molecular resistance test, the number of samples for which AMR can be determined increases facilitating earlier detection at a lower resistance proportion. For the best case scenario, where AMR can be determined for all diagnostic samples, the alert would be triggered at least 8 months earlier than using culture alone and the resistance proportion will have only slightly exceeded the 5% notification threshold.Molecular tests have the potential to provide more timely warning of the emergence of gonorrhoea AMR. This in turn will facilitate earlier treatment switching and more targeted treatment, which has the potential to reduce the population impact of gonorrhoea AMR.

  16. Exploring the Benefits of Molecular Testing for Gonorrhoea Antibiotic Resistance Surveillance in Remote Settings.

    Science.gov (United States)

    Hui, Ben B; Ryder, Nathan; Su, Jiunn-Yih; Ward, James; Chen, Marcus Y; Donovan, Basil; Fairley, Christopher K; Guy, Rebecca J; Lahra, Monica M; Law, Mathew G; Whiley, David M; Regan, David G

    2015-01-01

    Surveillance for gonorrhoea antimicrobial resistance (AMR) is compromised by a move away from culture-based testing in favour of more convenient nucleic acid amplification test (NAAT) tests. We assessed the potential benefit of a molecular resistance test in terms of the timeliness of detection of gonorrhoea AMR. An individual-based mathematical model was developed to describe the transmission of gonorrhoea in a remote Indigenous population in Australia. We estimated the impact of the molecular test on the time delay between first importation and the first confirmation that the prevalence of gonorrhoea AMR (resistance proportion) has breached the WHO-recommended 5% threshold (when a change in antibiotic should occur). In the remote setting evaluated in this study, the model predicts that when culture is the only available means of testing for AMR, the breach will only be detected when the actual prevalence of AMR in the population has already reached 8 - 18%, with an associated delay of ~43 - 69 months between first importation and detection. With the addition of a molecular resistance test, the number of samples for which AMR can be determined increases facilitating earlier detection at a lower resistance proportion. For the best case scenario, where AMR can be determined for all diagnostic samples, the alert would be triggered at least 8 months earlier than using culture alone and the resistance proportion will have only slightly exceeded the 5% notification threshold. Molecular tests have the potential to provide more timely warning of the emergence of gonorrhoea AMR. This in turn will facilitate earlier treatment switching and more targeted treatment, which has the potential to reduce the population impact of gonorrhoea AMR.

  17. Definition and taxonomy of interval colorectal cancers: a proposal for standardising nomenclature

    NARCIS (Netherlands)

    Sanduleanu, S.; le Clercq, C. M. C.; Dekker, E.; Meijer, G. A.; Rabeneck, L.; Rutter, M. D.; Valori, R.; Young, G. P.; Schoen, R. E.

    2015-01-01

    Interval colorectal cancers (interval CRCs), that is, cancers occurring after a negative screening test or examination, are an important indicator of the quality and effectiveness of CRC screening and surveillance. In order to compare incidence rates of interval CRCs across screening programmes, a

  18. Student Drug Testing and the Surveillance School Economy: An Analysis of Media Representation and Policy Transfer in Australian Schools

    Science.gov (United States)

    Taylor, Emmeline

    2018-01-01

    Anxieties relating to the health, safety and security of schoolchildren have been met with a variety of surveillance apparatus in schools internationally. Drawing on findings from a content analysis of newspaper reports relating to drug testing in Australian schools, this article seeks to excavate the ways in which the media shapes, informs,…

  19. Emergency Diesel Generation System Surveillance Test Policy Optimization Through Genetic Algorithms Using Non-Periodic Intervention Frequencies and Seasonal Constraints

    International Nuclear Information System (INIS)

    Lapa, Celso M.F.; Pereira, Claudio M.N.A.; Frutuoso e Melo, P.F.

    2002-01-01

    Nuclear standby safety systems must frequently, be submitted to periodic surveillance tests. The main reason is to detect, as soon as possible, the occurrence of unrevealed failure states. Such interventions may, however, affect the overall system availability due to component outages. Besides, as the components are demanded, deterioration by aging may occur, penalizing again the system performance. By these reasons, planning a good surveillance test policy implies in a trade-off between gains and overheads due to the surveillance test interventions. In order maximize the systems average availability during a given period of time, it has recently been developed a non-periodic surveillance test optimization methodology based on genetic algorithms (GA). The fact of allowing non-periodic tests turns the solution space much more flexible and schedules can be better adjusted, providing gains in the overall system average availability, when compared to those obtained by an optimized periodic tests scheme. The optimization problem becomes, however, more complex. Hence, the use of a powerful optimization technique, such as GAs, is required. Some particular features of certain systems can turn it advisable to introduce other specific constraints in the optimization problem. The Emergency Diesel Generation System (EDGS) of a Nuclear Power Plant (N-PP) is a good example for demonstrating the introduction of seasonal constraints in the optimization problem. This system is responsible for power supply during an external blackout. Therefore, it is desirable during periods of high blackout probability to maintain the system availability as high as possible. Previous applications have demonstrated the robustness and effectiveness of the methodology. However, no seasonal constraints have ever been imposed. This work aims at investigating the application of such methodology in the Angra-II Brazilian NPP EDGS surveillance test policy optimization, considering the blackout probability

  20. Estimation of RPV material embrittlement for Ukrainian NPP based on surveillance test data

    International Nuclear Information System (INIS)

    Revka, V.; Chyrko, L.; Chaikovsky, Yu.; Gulchuk, Yu.

    2012-01-01

    The WWER-1000 RPV material embrittlement has been evaluated using the surveillance test data for the nuclear power plant which is under operation in Ukraine. The RPV materials after the neutron (E > 0,5 MeV) irradiation up to fluence of 22,9.10 22 m -2 have been studied. Fracture toughness tests were performed using pre-cracked Charpy specimens for the beltline materials (base and weld metal). The maximum shift of T 0 reference temperature is equal to 44 o C. A radiation embrittlement rate, A F , for the RPV materials was estimated using the standard and reconstituted specimens. A comparison of the A F values has shown a good agreement between the specimen sets before and after reconstitution both for base and weld metal. Furthermore it has been revealed there is no nickel effect for the studied materials. In spite of the high nickel content the radiation embrittlement rate for weld metal is not higher than for base metal with low nickel content. Fracture toughness analysis has shown the Master curve shape describes well a temperature dependence of K Jc values. However a higher scatter of K Jc values is observed in comparison to 95 % tolerance bounds. (author)

  1. Improving the space surveillance telescope's performance using multi-hypothesis testing

    Energy Technology Data Exchange (ETDEWEB)

    Chris Zingarelli, J.; Cain, Stephen [Air Force Institute of Technology, 2950 Hobson Way, Bldg 641, Wright Patterson AFB, OH 45433 (United States); Pearce, Eric; Lambour, Richard [Lincoln Labratory, Massachusetts Institute of Technology, 244 Wood Street, Lexington, MA 02421 (United States); Blake, Travis [Defense Advanced Research Projects Agency, 675 North Randolph Street Arlington, VA 22203 (United States); Peterson, Curtis J. R., E-mail: John.Zingarelli@afit.edu [United States Air Force, 1690 Air Force Pentagon, Washington, DC 20330 (United States)

    2014-05-01

    The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.

  2. Logrank Test and Interval Overlap Test for Bactericera cockerelli (Hemiptera: Triozidae) Under Different Fertilization Treatments for 7705 Tomato Hybrid

    Science.gov (United States)

    Vargas-Madríz, Haidel; Bautista-Martínez, Néstor; Vera-Graziano, Jorge; Sánchez-García, Prometeo; García-Gutiérrez, Cipriano; Sánchez-Soto, Saúl; de Jesús García-Avila, Clemente

    2014-01-01

    Abstract It is known that some nutrients can have both negative and positive effects on some populations of insects. To test this, the Logrank test and the Interval Overlap Test were evaluated for two crop cycles (February–May and May–August) of the 7705 tomato hybrid, and the effect on the psyllid, Bactericera cockerelli (Sulc.) (Hemiptera: Triozidae), was examined under greenhouse conditions. Tomato plants were in polythene bags and irrigated with the following solutions: T1—Steiner solution, T2—Steiner solution with nitrogen reduced to 25%, T3—Steiner solution with potassium reduced to 25%, and T4—Steiner solution with calcium reduced to 25%. In the Logrank test, a significant difference was found when comparing the survival parameters of B. cockerelli generated from the treatment cohorts: T1–T2; T1–T3; T1–T4; T2–T3; and T3–T4, while no significant differences were found in the T2–T4 comparison in the February–May cycle. In the May–August cycle, significant differences were found when comparing the survival parameters generated from the treatment cohorts: T1–T2; T1–T3; and T1–T4, while no significant differences were found in the T2–T3; T2–T4; and T3–T4 comparisons of survival parameters of B. cockerelli fed with the 7705 tomato hybrid. Also, the Interval Overlap Test was done on the treatment cohorts (T1, T2, T3, and T4) in the February–May and May–August cycles. T1 and T2 compare similarly in both cycles when feeding on the treatments up to 36 d. Similarly, in T1 and T3, the behavior of the insect is similar when feeding on the treatments up to 40 and 73 d, respectively. Comparisons T2–T3 and T2–T4 are similar when feeding on both treatments up to 42, 38 and 37, 63 d, respectively. Finally, the T3–T4 comparison was similar when feeding in both treatments up to 20 and 46 d, respectively. RESUMEN. Se sabe que algunos nutrientes pueden tener efectos tanto negativos como positivos en algunas poblaciones de

  3. Human error considerations and annunciator effects in determining optimal test intervals for periodically inspected standby systems

    International Nuclear Information System (INIS)

    McWilliams, T.P.; Martz, H.F.

    1981-01-01

    This paper incorporates the effects of four types of human error in a model for determining the optimal time between periodic inspections which maximizes the steady state availability for standby safety systems. Such safety systems are characteristic of nuclear power plant operations. The system is modeled by means of an infinite state-space Markov chain. Purpose of the paper is to demonstrate techniques for computing steady-state availability A and the optimal periodic inspection interval tau* for the system. The model can be used to investigate the effects of human error probabilities on optimal availability, study the benefits of annunciating the standby-system, and to determine optimal inspection intervals. Several examples which are representative of nuclear power plant applications are presented

  4. Experience gained with the development of a performance test program for the monitoring and surveillance systems in the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Arestin, M.L.

    1988-01-01

    The monitoring and surveillance system for Embalse nuclear power plant are presented. The reactor, the nuclear fuel management, the equipments from monitoring and surveillance system, the activities developed by the AIEA experts in each mission of this test program and the management of the components for this test program in Argentine are described. (E.G.) [pt

  5. Specific antigen serologic tests in leprosy: implications for epidemiological surveillance of leprosy cases and household contacts.

    Science.gov (United States)

    Carvalho, Ana Paula Mendes; Coelho, Angélica da Conceição Oliveira; Correa-Oliveira, Rodrigo; Lana, Francisco Carlos Félix

    2017-09-01

    There is a lack of straightforward tests for field application and known biomarkers for predicting leprosy progression in infected individuals. The aim was to analyse the response to infection by Mycobacterium leprae based on the reactivity of specific antigens: natural disaccharide linked to human serum albumin via an octyl (NDOHSA), a semisynthetic phenolic glycolipid-I (PGL-I); Leprosy Infectious Disease Research Institute Diagnostic-1 (LID-1) and natural disaccharide octyl - Leprosy Infectious Disease Research Institute Diagnostic-1 (NDOLID). The study population consisted of 130 leprosy cases diagnosed between 2010 and 2015 and 277 household contacts. An enzyme-linked immunosorbent assay (ELISA) was used to analyse the reactivity of antibodies against NDOHSA, LID-1 and NDOLID. The samples and controls were tested in duplicate, and the antibody titer was expressed as an ELISA index. Data collection was made by home visits with application of questionnaire and dermatological evaluation of all household contacts to identify signs and symptoms of leprosy. Significant differences in the median ELISA results were observed among leprosy cases in treatment, leprosy cases that had completed treatment and household contacts. Higher proportions of seropositivity were observed in leprosy cases in treatment. Seropositivity was also higher in multibacillary in relation to paucibacillary, with the difference reaching statistical significance. Lower titers were observed among cases with a longer treatment time or discharge. For household contacts, the differences according to the clinical characteristics of the leprosy index case were less pronounced than expected. Other factors, such as the endemicity of leprosy, exposure outside the residence and genetic characteristics, appeared to have a greater influence on the seropositivity. Serologic tests could be used as auxiliary tools for determining the operational classification, in addition to identifying infected individuals

  6. Appropriate Frequency and Interval of Neck Ultrasonography Surveillance during the First 10 Years after Total Thyroidectomy in Patients with Papillary Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Yoo Jin Lee

    2018-03-01

    Full Text Available BackgroundNo previous study has employed the frequency and interval of follow-up ultrasonography (US during the first 10 years after total thyroidectomy in patients with papillary thyroid carcinoma (PTC. The aim of this study was to determine the appropriate frequency and interval of follow-up US during the first 10 years in patients who have undergone total thyroidectomy for PTC.MethodsTwo hundred seventy-two patients underwent total thyroidectomy for PTC at our institution from January 2006 to December 2007. Nineteen patients were excluded because of lack of US follow-up data for the neck. Follow-up US was performed by one of two radiologists in all patients. Tumor recurrence/persistence was confirmed by histopathology.ResultsThe mean interval between surgery and the final follow-up US examination was 79.0 months, and the mean number of follow-up US sessions was 5.9 in the 253 evaluable patients. Eleven patients (4.3% developed tumor recurrence/persistence, which was detected on follow-up US within 5 years after total thyroidectomy in all cases. T and N stages were independently associated with tumor recurrence/persistence. The interval between surgery and first suspicion of tumor recurrence/persistence on follow-up US was ≤12 months in six patients and 20, 35, 41, 53, and 60 months in the remaining five patients.ConclusionFor detection of tumor recurrence/persistence after total thyroidectomy in patients with PTC, one or two sessions of follow-up US during the first 2 years, depending on T and N stages and one session of follow-up US in every second year during the following 8 years may be appropriate.

  7. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Directory of Open Access Journals (Sweden)

    Sean C Murphy

    Full Text Available Nucleic acid testing (NAT for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally <0.5 log10 parasites/mL except for one laboratory where the EQA effort identified likely reasons for a general quantitative shift. The within-laboratory variation for all assays was low at <10% coefficient of variation across a range of parasite densities. Based on this study, we propose to create a Molecular Malaria Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  8. Use of Reactor Pressure Vessel Surveillance Materials for Extended Life Evaluations Using Power and Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Server, W.L.; Nanstad, R.K.; Odette, G.R.

    2012-01-01

    The most important component in assuring safety of the nuclear power plant is the reactor pressure (RPV). Surveillance programs have been designed to cover the licensed life of operating nuclear RPVs. The original surveillance programs were designed when the licensed life was 40 years. More than one-half of the operating nuclear plants in the USA have an extended license out to 60 years, and there are plans to continue to operate many plants out to 80 years. Therefore, the surveillance programs have had to be adjusted or enhanced to generate key data for 60 years, and now consideration must be given for 80 or more years. To generate the necessary data to assure safe operation out to these extended license lives, test reactor irradiations have been initiated with key RPV and model alloy steels, which include several steels irradiated in the current power reactor surveillance programs out to relatively high fluence levels. These data are crucial in understanding the radiation embrittlement mechanisms and to enable extrapolation of the irradiation effects on mechanical properties for these extended time periods. This paper describes the potential radiation embrittlement mechanisms and effects when assessing much longer operating times and higher neutron fluence levels. Potential methods for adjusting higher neutron flux test reactor data for use in predicting power reactor vessel conditions are discussed. (author)

  9. Hot cell examination on the surveillance capsule of SA 533 cl. 1 reactor pressure vessel (1st test report)

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yong Sun; Jung, Y. H.; Yoo, B. O.; Baik, S. J.; Oh, W. H.; Soong, W. S.; Hong, K. P

    2000-08-01

    The post-irradiated examinations such as impact test, tensile test, composition analysis and etc. were conducted to monitor and to evaluate the radiation-induced changes, so called radiation embrittlement, in the mechanical properties of ferritic materials. Those data should be applied to confirm safety as well as reliability of reactor pressure vessel. The scopes and contents of hot cell examination on the surveillance capsule are as follows; - Capsule transportation, cutting, dismantling and classification - Shim block and Dosimeter cutting and dismantling - Impact test - Tensile test - Composition analysis by EPMA - SEM observation on the fractured surface - Hardness test - Radwaste treatment.

  10. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  11. Analysis of the surveillance test data on irradiation embrittlement of the reactor pressure vessel steels in LWRs

    International Nuclear Information System (INIS)

    Lee, Gyoeng Geun; Kwon, Jun Hyun

    2010-11-01

    The surveillance test data in Korean LWRs were analyzed from a viewpoint of materials science. TTS change with the neutron irradiation were compared to the model values of the RG1.99/2 and NUREG/CR-6551. The model values of TTS were higher than the actual values of TTS. It was impossible to find a relationship between TTS and neutron fluence in weld data. The correlation of the increase in YS (yield strength) and TTS with neutron irradiation was also investigated. Like the result of TTS change, the YS/TTS showed the correlations in plate/forgings metals, however no correlation in weld metals. The data were similar to Odette's result about US surveillance tests. From the empirical relationships, the TTS curve change could be predicted using the CVN test result of the unirradiated specimen and the change in YS with neutron irradiation of the specimen

  12. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  13. A Comparative Test of the Interval-Scale Properties of Magnitude Estimation and Case III Scaling and Recommendations for Equal-Interval Frequency Response Anchors.

    Science.gov (United States)

    Schriesheim, Chester A.; Novelli, Luke, Jr.

    1989-01-01

    Differences between recommended sets of equal-interval response anchors derived from scaling techniques using magnitude estimations and Thurstone Case III pair-comparison treatment of complete ranks were compared. Differences in results for 205 undergraduates reflected differences in the samples as well as in the tasks and computational…

  14. Appropriateness of endoscopic surveillance recommendations in organised colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Turrin, Anna; Mantellini, Paola; Visioli, Carmen Beatriz; Naldoni, Carlo; Sassoli De' Bianchi, Priscilla; Fedato, Chiara; Anghinoni, Emanuela; Zappa, Marco; Hassan, Cesare

    2016-11-01

    To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). 74 Italian CRC screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013. 49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05). In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Component unavailability versus inservice test (IST) interval: Evaluations of component aging effects with applications to check valves

    International Nuclear Information System (INIS)

    Vesely, W.E.; Poole, A.B.

    1997-07-01

    Methods are presented for calculating component unavailabilities when inservice test (IST) intervals are changed and when component aging is explicitly included. The methods extend usual approaches for calculating unavailability and risk effects of changing IST intervals which utilize Probabilistic Risk Assessment (PRA) methods that do not explicitly include component aging. Different IST characteristics are handled including ISTs which are followed by corrective maintenances which completely renew or partially renew the component. ISTs which are not followed by maintenance activities needed to renew the component are also handled. Any downtime associated with IST, including the test downtime and the following maintenance downtime, is included in the unavailability evaluations. A range of component aging behaviors is studied including both linear and nonlinear aging behaviors. Based upon evaluations completed to date, pooled failure data on check valves show relatively small aging (e.g., less than 7% per year). However, data from some plant systems could be evidence for larger aging rates occurring in time periods less than 5 years. The methods are utilized in this report to carry out a range of sensitivity evaluations to evaluate aging effects for different possible applications. Based on the sensitivity evaluations, summary tables are constructed showing how optimal IST interval ranges for check valves can vary relative to different aging behaviors which might exist. The evaluations are also used to identify IST intervals for check valves which are robust to component aging effects. General insights on aging effects are also extracted. These sensitivity studies and extracted results provide useful information which can be supplemented or be updated with plant specific information. The models and results can also be input to PRAs to determine associated risk implications

  16. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  17. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  18. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  19. Analysis of well test data from selected intervals in Leuggern deep borehole

    International Nuclear Information System (INIS)

    Karasaki, K.

    1990-07-01

    Applicability of the PTST technique was verified by conducting a sensitivity study to the various parameters. The study showed that for ranges of skin parameters the true formation permeability was still successfully estimated using the PTST analysis technique. The analysis technique was then applied to field data from the deep borehole in Leuggern, Northern Switzerland. The analysis indicated that the formation permeability may be as much as one order of magnitude larger than the value based on no-skin analysis. Swabbing data from the Leuggern deep borehole were also analyzed assuming that they are constant pressure tests. The analysis of the swabbing data indicates that the formation transmissivity is as much as 20 times larger than the previously obtained value. This study is part of an investigation of the feasibility of geologic isolation of nuclear wastes being carried out by the US Department of Energy and the National Cooperative for the Storage of Radioactive Waste of Switzerland

  20. Final report : mobile surveillance and wireless communication systems field operational test. Volume 2, FOT objectives, organization, system design, results, conclusions, and recommendations

    Science.gov (United States)

    1999-03-01

    The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...

  1. Effect of Remote Back-Up Protection System Failure on the Optimum Routine Test Time Interval of Power System Protection

    Directory of Open Access Journals (Sweden)

    Y Damchi

    2013-12-01

    Full Text Available Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.

  2. Considerations about expected a posteriori estimation in adaptive testing: adaptive a priori, adaptive correction for bias, and adaptive integration interval.

    Science.gov (United States)

    Raiche, Gilles; Blais, Jean-Guy

    2009-01-01

    In a computerized adaptive test, we would like to obtain an acceptable precision of the proficiency level estimate using an optimal number of items. Unfortunately, decreasing the number of items is accompanied by a certain degree of bias when the true proficiency level differs significantly from the a priori estimate. The authors suggest that it is possible to reduced the bias, and even the standard error of the estimate, by applying to each provisional estimation one or a combination of the following strategies: adaptive correction for bias proposed by Bock and Mislevy (1982), adaptive a priori estimate, and adaptive integration interval.

  3. A niching genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Sacco, W.F.; Lapa, Celso M.F.; Pereira, C.M.N.A.; Oliveira, C.R.E. de

    2006-01-01

    This article extends previous efforts on genetic algorithms (GAs) applied to a nuclear power plant (NPP) auxiliary feedwater system (AFWS) surveillance tests policy optimization. We introduce the application of a niching genetic algorithm (NGA) to this problem and compare its performance to previous results. The NGA maintains a populational diversity during the search process, thus promoting a greater exploration of the search space. The optimization problem consists in maximizing the system's average availability for a given period of time, considering realistic features such as: (i) aging effects on standby components during the tests; (ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; (iii) components have distinct test parameters (outage time, aging factors, etc.) and (iv) tests are not necessarily periodic. We find that the NGA performs better than the conventional GA and the island GA due to a greater exploration of the search space

  4. Peak oxygen uptake in a sprint interval testing protocol vs. maximal oxygen uptake in an incremental testing protocol and their relationship with cross-country mountain biking performance.

    Science.gov (United States)

    Hebisz, Rafał; Hebisz, Paulina; Zatoń, Marek; Michalik, Kamil

    2017-04-01

    In the literature, the exercise capacity of cyclists is typically assessed using incremental and endurance exercise tests. The aim of the present study was to confirm whether peak oxygen uptake (V̇O 2peak ) attained in a sprint interval testing protocol correlates with cycling performance, and whether it corresponds to maximal oxygen uptake (V̇O 2max ) determined by an incremental testing protocol. A sample of 28 trained mountain bike cyclists executed 3 performance tests: (i) incremental testing protocol (ITP) in which the participant cycled to volitional exhaustion, (ii) sprint interval testing protocol (SITP) composed of four 30 s maximal intensity cycling bouts interspersed with 90 s recovery periods, (iii) competition in a simulated mountain biking race. Oxygen uptake, pulmonary ventilation, work, and power output were measured during the ITP and SITP with postexercise blood lactate and hydrogen ion concentrations collected. Race times were recorded. No significant inter-individual differences were observed in regards to any of the ITP-associated variables. However, 9 individuals presented significantly increased oxygen uptake, pulmonary ventilation, and work output in the SITP compared with the remaining cyclists. In addition, in this group of 9 cyclists, oxygen uptake in SITP was significantly higher than in ITP. After the simulated race, this group of 9 cyclists achieved significantly better competition times (99.5 ± 5.2 min) than the other cyclists (110.5 ± 6.7 min). We conclude that mountain bike cyclists who demonstrate higher peak oxygen uptake in a sprint interval testing protocol than maximal oxygen uptake attained in an incremental testing protocol demonstrate superior competitive performance.

  5. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    Science.gov (United States)

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  6. Comparison of rate theory based modeling calculations with the surveillance test results of Korean light water reactors

    International Nuclear Information System (INIS)

    Lee, Gyeong Geun; Lee, Yong Bok; Kim, Min Chul; Kwon, Junh Yun

    2012-01-01

    Neutron irradiation to reactor pressure vessel (RPV) steels causes a decrease in fracture toughness and an increase in yield strength while in service. It is generally accepted that the growth of point defect cluster (PDC) and copper rich precipitate (CRP) affects radiation hardening of RPV steels. A number of models have been proposed to account for the embrittlement of RPV steels. The rate theory based modeling mathematically described the evolution of radiation induced microstructures of ferritic steels under neutron irradiation. In this work, we compared the rate theory based modeling calculation with the surveillance test results of Korean Light Water Reactors (LWRs)

  7. Pacemaker patients’ perspective and experiences in a pacemaker outpatient clinic in relation to test intervals of the pacemaker

    DEFF Research Database (Denmark)

    Lauberg, Astrid; Hansen, Tina; Pedersen, Trine Pernille Dahl

    an evident decline in quality of life regarding psychological and social aspects 6 month after the implantation in terms of cognitive function, work ability, and sexual activity. Mlynarski et al (2009) have found correlations between pacemaker implantation and anxiety and depression. Aim The aim...... the pacemaker and psychological reactions. Patients with pacemakers older than 3 months lacked communication with fellowmen. Conclusion The patients express receiving competent and professional treatment when visiting the outpatient clinic, there seems to be a discrepancy between the long test intervals...... and the critical period in which anxiety and depression may occur. Minor problems and questions may grow into fatal conditions if the patients are not offered an opportunity to discuss this with experts. Patients are not informed that it is possible to discuss problems that imply psychological topics and they do...

  8. Optimization of the test intervals of a nuclear safety system by genetic algorithms, solution clustering and fuzzy preference assignment

    International Nuclear Information System (INIS)

    Zio, E.; Bazzo, R.

    2010-01-01

    In this paper, a procedure is developed for identifying a number of representative solutions manageable for decision-making in a multiobjective optimization problem concerning the test intervals of the components of a safety system of a nuclear power plant. Pareto Front solutions are identified by a genetic algorithm and then clustered by subtractive clustering into 'families'. On the basis of the decision maker's preferences, each family is then synthetically represented by a 'head of the family' solution. This is done by introducing a scoring system that ranks the solutions with respect to the different objectives: a fuzzy preference assignment is employed to this purpose. Level Diagrams are then used to represent, analyze and interpret the Pareto Fronts reduced to the head-of-the-family solutions

  9. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  10. Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Directory of Open Access Journals (Sweden)

    Sluiter Judith K

    2010-02-01

    Full Text Available Abstract Background Clinimetric data for the fire fighting simulation test (FFST, a new test proposed for the Workers' Health Surveillance (WHS of Dutch fire fighters, were evaluated. Methods Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC, and standard error of measurement (SEM, were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. Results The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p Conclusions The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.

  11. Development of a test of suprathreshold acuity in noise in Brazilian Portuguese: a new method for hearing screening and surveillance.

    Science.gov (United States)

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  12. Development of a Test of Suprathreshold Acuity in Noise in Brazilian Portuguese: A New Method for Hearing Screening and Surveillance

    Directory of Open Access Journals (Sweden)

    Nara Vaez

    2014-01-01

    Full Text Available This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light, “a hearing check would be advisable” (yellow light, and “no hearing difficulties” (green light (Paglialonga et al., Comput. Biol. Med. 2014. This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  13. Post-treatment surveillance testing of patients with colorectal cancer and the association with survival: protocol for a retrospective cohort study of the Surveillance, Epidemiology, and End Results (SEER)-Medicare database.

    Science.gov (United States)

    Hines, Robert B; Jiban, Md Jibanul Haque; Choudhury, Kanak; Loerzel, Victoria; Specogna, Adrian V; Troy, Steven P; Zhang, Shunpu

    2018-04-28

    Although the colorectal cancer (CRC) mortality rate has significantly improved over the past several decades, many patients will have a recurrence following curative treatment. Despite this high risk of recurrence, adherence to CRC surveillance testing guidelines is poor which increases cancer-related morbidity and potentially, mortality. Several randomised controlled trials (RCTs) with varying surveillance strategies have yielded conflicting evidence regarding the survival benefit associated with surveillance testing. However, due to differences in study protocols and limitations of sample size and length of follow-up, the RCT may not be the best study design to evaluate this relationship. An observational comparative effectiveness research study can overcome the sample size/follow-up limitations of RCT designs while assessing real-world variability in receipt of surveillance testing to provide much needed evidence on this important clinical issue. The gap in knowledge that this study will address concerns whether adherence to National Comprehensive Cancer Network CRC surveillance guidelines improves survival. Patients with colon and rectal cancer aged 66-84 years, who have been diagnosed between 2002 and 2008 and have been included in the Surveillance, Epidemiology, and End Results-Medicare database, are eligible for this retrospective cohort study. To minimise bias, patients had to survive at least 12 months following the completion of treatment. Adherence to surveillance testing up to 5 years post-treatment will be assessed in each year of follow-up and overall. Binomial regression will be used to assess the association between patients' characteristics and adherence. Survival analysis will be conducted to assess the association between adherence and 5-year survival. This study was approved by the National Cancer Institute and the Institutional Review Board of the University of Central Florida. The results of this study will be disseminated by publishing in

  14. HIV incidence in rural South Africa: comparison of estimates from longitudinal surveillance and cross-sectional cBED assay testing.

    Directory of Open Access Journals (Sweden)

    Till Bärnighausen

    Full Text Available The BED IgG-Capture Enzyme Immunoassay (cBED assay, a test of recent HIV infection, has been used to estimate HIV incidence in cross-sectional HIV surveys. However, there has been concern that the assay overestimates HIV incidence to an unknown extent because it falsely classifies some individuals with non-recent HIV infections as recently infected. We used data from a longitudinal HIV surveillance in rural South Africa to measure the fraction of people with non-recent HIV infection who are falsely classified as recently HIV-infected by the cBED assay (the long-term false-positive ratio (FPR and compared cBED assay-based HIV incidence estimates to longitudinally measured HIV incidence.We measured the long-term FPR in individuals with two positive HIV tests (in the HIV surveillance, 2003-2006 more than 306 days apart (sample size n = 1,065. We implemented four different formulae to calculate HIV incidence using cBED assay testing (n = 11,755 and obtained confidence intervals (CIs by directly calculating the central 95(th percentile of incidence values. We observed 4,869 individuals over 7,685 person-years for longitudinal HIV incidence estimation. The long-term FPR was 0.0169 (95% CI 0.0100-0.0266. Using this FPR, the cross-sectional cBED-based HIV incidence estimates (per 100 people per year varied between 3.03 (95% CI 2.44-3.63 and 3.19 (95% CI 2.57-3.82, depending on the incidence formula. Using a long-term FPR of 0.0560 based on previous studies, HIV incidence estimates varied between 0.65 (95% CI 0.00-1.32 and 0.71 (95% CI 0.00-1.43. The longitudinally measured HIV incidence was 3.09 per 100 people per year (95% CI 2.69-3.52, after adjustment to the sex-age distribution of the sample used in cBED assay-based estimation.In a rural community in South Africa with high HIV prevalence, the long-term FPR of the cBED assay is substantially lower than previous estimates. The cBED assay performs well in HIV incidence estimation if the locally

  15. Cost-effectiveness of lobectomy versus genetic testing (Afirma®) for indeterminate thyroid nodules: Considering the costs of surveillance.

    Science.gov (United States)

    Balentine, Courtney J; Vanness, David J; Schneider, David F

    2018-01-01

    We evaluated whether diagnostic thyroidectomy for indeterminate thyroid nodules would be more cost-effective than genetic testing after including the costs of long-term surveillance. We used a Markov decision model to estimate the cost-effectiveness of thyroid lobectomy versus genetic testing (Afirma®) for evaluation of indeterminate (Bethesda 3-4) thyroid nodules. The base case was a 40-year-old woman with a 1-cm indeterminate nodule. Probabilities and estimates of utilities were obtained from the literature. Cost estimates were based on Medicare reimbursements with a 3% discount rate for costs and quality-adjusted life-years. During a 5-year period after the diagnosis of indeterminate thyroid nodules, lobectomy was less costly and more effective than Afirma® (lobectomy: $6,100; 4.50 quality-adjusted life- years vs Afirma®: $9,400; 4.47 quality-adjusted life-years). Only in 253 of 10,000 simulations (2.5%) did Afirma® show a net benefit at a cost-effectiveness threshold of $100,000 per quality- adjusted life-years. There was only a 0.3% probability of Afirma® being cost saving and a 14.9% probability of improving quality-adjusted life-years. Our base case estimate suggests that diagnostic lobectomy dominates genetic testing as a strategy for ruling out malignancy of indeterminate thyroid nodules. These results, however, were highly sensitive to estimates of utilities after lobectomy and living under surveillance after Afirma®. Published by Elsevier Inc.

  16. Evaluation of the Trail Making Test and interval timing as measures of cognition in healthy adults: comparisons by age, education, and gender.

    Science.gov (United States)

    Płotek, Włodzimierz; Łyskawa, Wojciech; Kluzik, Anna; Grześkowiak, Małgorzata; Podlewski, Roland; Żaba, Zbigniew; Drobnik, Leon

    2014-02-03

    Human cognitive functioning can be assessed using different methods of testing. Age, level of education, and gender may influence the results of cognitive tests. The well-known Trail Making Test (TMT), which is often used to measure the frontal lobe function, and the experimental test of Interval Timing (IT) were compared. The methods used in IT included reproduction of auditory and visual stimuli, with the subsequent production of the time intervals of 1-, 2-, 5-, and 7-seconds durations with no pattern. Subjects included 64 healthy adult volunteers aged 18-63 (33 women, 31 men). Comparisons were made based on age, education, and gender. TMT was performed quickly and was influenced by age, education, and gender. All reproduced visual and produced intervals were shortened and the reproduction of auditory stimuli was more complex. Age, education, and gender have more pronounced impact on the cognitive test than on the interval timing test. The reproduction of the short auditory stimuli was more accurate in comparison to other modalities used in the IT test. The interval timing, when compared to the TMT, offers an interesting possibility of testing. Further studies are necessary to confirm the initial observation.

  17. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    Science.gov (United States)

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  18. Parallel island genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Pereira, Claudio M.N.A.; Lapa, Celso M.F.

    2003-01-01

    In this work, we focus the application of an Island Genetic Algorithm (IGA), a coarse-grained parallel genetic algorithm (PGA) model, to a Nuclear Power Plant (NPP) Auxiliary Feedwater System (AFWS) surveillance tests policy optimization. Here, the main objective is to outline, by means of comparisons, the advantages of the IGA over the simple (non-parallel) genetic algorithm (GA), which has been successfully applied in the solution of such kind of problem. The goal of the optimization is to maximize the system's average availability for a given period of time, considering realistic features such as: i) aging effects on standby components during the tests; ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; iii) components have distinct test parameters (outage time, aging factors, etc.) and iv) tests are not necessarily periodic. In our experiments, which were made in a cluster comprised by 8 1-GHz personal computers, we could clearly observe gains not only in the computational time, which reduced linearly with the number of computers, but in the optimization outcome

  19. Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized. 1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm2 and accurate results at higher track densities have been demonstrated for some cases. (2) Trac...

  20. Long-Term Maintenance of Immediate or Delayed Extinction Is Determined by the Extinction-Test Interval

    Science.gov (United States)

    Johnson, Justin S.; Escobar, Martha; Kimble, Whitney L.

    2010-01-01

    Short acquisition-extinction intervals (immediate extinction) can lead to either more or less spontaneous recovery than long acquisition-extinction intervals (delayed extinction). Using rat subjects, we observed less spontaneous recovery following immediate than delayed extinction (Experiment 1). However, this was the case only if a relatively…

  1. Risk factors for changing test classification in the Danish surveillance program for Salmonella in dairy herds

    DEFF Research Database (Denmark)

    Nielsen, Lennarth Ravn; Warnick, L. D.; Greiner, M.

    2007-01-01

    test positive to negative, whereas the breed and neighbor factors were not found to be important for small herds. Organic production was associated with remaining test positive, but not with becoming test positive. The results emphasize the importance of external and internal biosecurity measures....... The objective of this study was to evaluate risk factors for changing from test negative to positive, which was indicative of herds becoming infected from one quarter of the year to the next, and risk factors for changing from test positive to negative, which was indicative of herds recovering from infection...

  2. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  3. Foucault, surveillance, and carbon monoxide testing within stop-smoking services.

    Science.gov (United States)

    Grant, Aimee; Ashton, Kathryn; Phillips, Rhiannon

    2015-07-01

    Health professionals have adopted proactive testing for early evidence of disease. Researchers have identified that this leads to enumerated understandings and shapes behavior in productive ways. Smoking-cessation advisors regularly test clients for carbon monoxide (CO), but client views of this had not previously been explored. We interviewed 23 clients of a United Kingdom-based stop-smoking service regarding their experiences of CO testing. The majority of participants were successful quitters. We used ATLAS.ti 7 as a data-management tool during structured qualitative analysis. Our findings reveal that clients believed the results of their CO tests. Many became enumerated in their understanding, and thus placed themselves in a hierarchy with other members of their group. Almost all clients found that knowing their CO test score was motivating. We conclude that additional research is needed to understand the experiences of CO testing among clients who do not quit. © The Author(s) 2014.

  4. Surveillance testing of onsite electrical power systems, several cases of standards misinterpretation in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Recarte, I.; Cid, R. [Consejo de Seguridad Nuclear, Sor Angela de la Cruz, 3, Madrid 28016 (Spain)

    1986-02-15

    Two events related with the onsite electric Systems of Spanish nuclear power plants are discussed. The first of them is related with diesel generators, its compliance with technical specifications; with the valid test, failure classification and frequency of tests as defined in Regulatory Guide 1.108. The other problem concerns of the direct current batteries. Presently they are subject by technical specifications to testing of a discharge cycle for which they were not designed. (authors)

  5. Improving national surveillance of Lyme neuroborreliosis in Denmark through electronic reporting of specific antibody index testing from 2010 to 2012

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Espenhain, L; Mølbak, K

    2015-01-01

    Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer of labora......Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer...

  6. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  7. Empirical likelihood-based confidence intervals for the sensitivity of a continuous-scale diagnostic test at a fixed level of specificity.

    Science.gov (United States)

    Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi

    2011-06-01

    For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.

  8. Unexplained Graft Dysfunction after Heart Transplantation—Role of Novel Molecular Expression Test Score and QTc-Interval: A Case Report

    Directory of Open Access Journals (Sweden)

    Khurram Shahzad

    2010-01-01

    Full Text Available In the current era of immunosuppressive medications there is increased observed incidence of graft dysfunction in the absence of known histological criteria of rejection after heart transplantation. A noninvasive molecular expression diagnostic test was developed and validated to rule out histological acute cellular rejection. In this paper we present for the first time, longitudinal pattern of changes in this novel diagnostic test score along with QTc-interval in a patient who was admitted with unexplained graft dysfunction. Patient presented with graft failure with negative findings on all known criteria of rejection including acute cellular rejection, antibody mediated rejection and cardiac allograft vasculopathy. The molecular expression test score showed gradual increase and QTc-interval showed gradual prolongation with the gradual decline in graft function. This paper exemplifies that in patients presenting with unexplained graft dysfunction, GEP test score and QTc-interval correlate with the changes in the graft function.

  9. JOINT INTELLIGENCE, SURVEILLANCE, & RECONNAISSANCE (ISR) TEST & EVALUATION (JISR-TE) FACILITY

    Data.gov (United States)

    Federal Laboratory Consortium — To meet the needs of the Warfighter, the JISR-TE facility provides the US, NATO, and Coalition members standards conformance testing of imagery capabilities across...

  10. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  11. Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program. PSF Blind Test workshop minutes. Summary

    International Nuclear Information System (INIS)

    Guthrie, G.L.; Lippincott, E.P.; McGarry, E.D.

    1984-01-01

    A ''Blind Test'' workshop was held on April 9-11, 1984, at the Holiday Inn in Richland, WA. At the workshop, participant groups compared ''Blind'' calculations with existing data which was unavailable to them at the time the calculations were made. The purpose of the exercise was to allow each participant group to test the group's ability to predict ''in-wall'' mechanical property degradation for a simulated nuclear reactor pressure vessel irradiation

  12. The time interval distribution of sand–dust storms in theory: testing with observational data for Yanchi, China

    International Nuclear Information System (INIS)

    Liu, Guoliang; Zhang, Feng; Hao, Lizhen

    2012-01-01

    We previously introduced a time record model for use in studying the duration of sand–dust storms. In the model, X is the normalized wind speed and Xr is the normalized wind speed threshold for the sand–dust storm. X is represented by a random signal with a normal Gaussian distribution. The storms occur when X ≥ Xr. From this model, the time interval distribution of N = Aexp(−bt) can be deduced, wherein N is the number of time intervals with length greater than t, A and b are constants, and b is related to Xr. In this study, sand–dust storm data recorded in spring at the Yanchi meteorological station in China were analysed to verify whether the time interval distribution of the sand–dust storms agrees with the above time interval distribution. We found that the distribution of the time interval between successive sand–dust storms in April agrees well with the above exponential equation. However, the interval distribution for the sand–dust storm data for the entire spring period displayed a better fit to the Weibull equation and depended on the variation of the sand–dust storm threshold wind speed. (paper)

  13. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  14. Reliability Estimation Based Upon Test Plan Results

    National Research Council Canada - National Science Library

    Read, Robert

    1997-01-01

    The report contains a brief summary of aspects of the Maximus reliability point and interval estimation technique as it has been applied to the reliability of a device whose surveillance tests contain...

  15. A pilot study to evaluate an efficient testing strategy for surveillance ...

    African Journals Online (AJOL)

    Introduction: Control strategies for schistosomiasis depend on the understanding of the population specific magnitude of the infection. We present pilot results of a testing strategy suggested by theoretical statistical investigation that lowers cost yet retains similar accuracy profile as the standard Kato-Katz technique.

  16. Notes on testing equality and interval estimation in Poisson frequency data under a three-treatment three-period crossover trial.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2016-10-01

    When the frequency of event occurrences follows a Poisson distribution, we develop procedures for testing equality of treatments and interval estimators for the ratio of mean frequencies between treatments under a three-treatment three-period crossover design. Using Monte Carlo simulations, we evaluate the performance of these test procedures and interval estimators in various situations. We note that all test procedures developed here can perform well with respect to Type I error even when the number of patients per group is moderate. We further note that the two weighted-least-squares (WLS) test procedures derived here are generally preferable to the other two commonly used test procedures in the contingency table analysis. We also demonstrate that both interval estimators based on the WLS method and interval estimators based on Mantel-Haenszel (MH) approach can perform well, and are essentially of equal precision with respect to the average length. We use a double-blind randomized three-treatment three-period crossover trial comparing salbutamol and salmeterol with a placebo with respect to the number of exacerbations of asthma to illustrate the use of these test procedures and estimators. © The Author(s) 2014.

  17. Field Evaluation of a Coproantigen Detection Test for Fascioliasis Diagnosis and Surveillance in Human Hyperendemic Areas of Andean Countries

    Science.gov (United States)

    Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago

    2012-01-01

    Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase

  18. Field evaluation of a coproantigen detection test for fascioliasis diagnosis and surveillance in human hyperendemic areas of Andean countries.

    Directory of Open Access Journals (Sweden)

    María Adela Valero

    Full Text Available Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA was evaluated, using classical techniques for egg detection for comparison.A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD and infection intensity by eggs per gram of feces (epg in Cajamarca low burden cases (<400 epg, nor in Huacullani high burden cases (≥ 400 epg, although there was in Huacullani low burden cases (<400 epg. Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg.The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase, early detection of treatment failure

  19. Five-Year Risk of Interval-Invasive Second Breast Cancer

    Science.gov (United States)

    Buist, Diana S. M.; Houssami, Nehmat; Dowling, Emily C.; Halpern, Elkan F.; Gazelle, G. Scott; Lehman, Constance D.; Henderson, Louise M.; Hubbard, Rebecca A.

    2015-01-01

    Background: Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. Methods: We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. Results: The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. Conclusions: PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. PMID:25904721

  20. Results of cytogenetic surveillance of rural populations adjoining to Semipalatinsk test site

    International Nuclear Information System (INIS)

    Abdil'dinova, G.Zh.; Kundakbaeva, G.B.; Zhunusova, A.B.

    1997-01-01

    Purpose of the work is study of somatic cytogenetic effects with taking into consideration chromosomal aberration of population from Beskaragaj district of Semipalatinsk region exposed to influence of conducted nuclear tests on Semipalatinsk test site. Cultures of lymphocyates of peripheral flood were studied. Control group made up 15 man living in Akmola region locating out of radiation contaminated zone. It is determined, that common frequency of chromosomal aberration make up 3.6 on 100 cells. At that frequency of pair fragments made up 2.0 on 100 metaphases (0.2 in control group); dicentrics and center rings were revealed with summary frequency 0.6 on 100 metaphases and that is approximately in 15 fold greater than control index - 0.03 on 100 cells. Stable radiation markers (translocations, deletions) revealed with frequency 1.07 on 100 cells (control make up 0.4 on 100 cells). By results of of conducted cytogenetic analysis the attempt of mean group effective equivalent dose reconstruction received with inhabitants of Beskaragaj district is undertaken. It was calculated, that population of researched district have been got dose loading in 9.09 rem

  1. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  2. The effect of the inter-phase delay interval in the spontaneous object recognition test for pigs

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Thygesen, Kristin Sjølie; Nielsen, Thomas Rune

    2007-01-01

    In the neuroscience community interest for using the pig is growing. Several disease models have been developed creating a need for validation of behavioural paradigms in these animals. Here, we report the effect of different inter-phase delay intervals on the performance of Göttingen minipigs...

  3. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning

    International Nuclear Information System (INIS)

    Siqueira, Newton Norat

    2006-12-01

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  4. Reactivity anomaly surveillance in the Fast Flux Test Facility through cycle 3

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.

    1984-08-01

    The technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and thus provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state. Initial results of using this technique based mainly on theoretical formulations is presented. The results show that the reactivity changes due to increasing reactor power (power defect) and burnup of the fuel were within approx. 16% of predicted values. To increase the sensitivity and accuracy of this technique, the prediction algorithms were calibrated to actual operating data. The work of calibrating this technique and the results of using the calibrated technique up through the third full operating cycle are summarized

  5. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  6. Short-interval test-retest interrater reliability of the Dutch version of the structured clinical interview for DSM-IV personality disorders (SCID-II)

    NARCIS (Netherlands)

    Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S

    2003-01-01

    This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The

  7. Testing equality and interval estimation in binary responses when high dose cannot be used first under a three-period crossover design.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    When comparing two doses of a new drug with a placebo, we may consider using a crossover design subject to the condition that the high dose cannot be administered before the low dose. Under a random-effects logistic regression model, we focus our attention on dichotomous responses when the high dose cannot be used first under a three-period crossover trial. We derive asymptotic test procedures for testing equality between treatments. We further derive interval estimators to assess the magnitude of the relative treatment effects. We employ Monte Carlo simulation to evaluate the performance of these test procedures and interval estimators in a variety of situations. We use the data taken as a part of trial comparing two different doses of an analgesic with a placebo for the relief of primary dysmenorrhea to illustrate the use of the proposed test procedures and estimators.

  8. Study on risk insight for additional ILRT interval extension

    International Nuclear Information System (INIS)

    Seo, M. R.; Hong, S. Y.; Kim, M. K.; Chung, B. S.; Oh, H. C.

    2005-01-01

    In U.S., the containment Integrated Leakage Rate Test (ILRT) interval was extended from 3 times per 10 years to once per 10 years based on NUREG-1493 'Performance-Based Containment Leak-Test Program' in 1995. In September, 2001, ILRT interval was extended up to once per 15 years based on Nuclear Energy Industry (NEI) provisional guidance 'Interim Guidance for Performing Risk Impact Assessments In Support of One-Time Extensions for Containment Integrated Leakage Rate Test Surveillance Intervals'. In Korea, the containment ILRT was performed with 5 year interval. But, in MOST(Ministry of Science and Technology) Notice 2004-15 'Standard for the Leak- Rate Test of the Nuclear Reactor Containment', the extension of the ILRT interval to once per 10 year can be allowed if some conditions are met. So, the safety analysis for the extension of Yonggwang Nuclear (YGN) Unit 1 and 2 ILRT interval extension to once per 10 years was completed based on the methodology in NUREG-1493. But, during review process by regulatory body, KINS, it was required that some various risk insight or index for risk analysis should be developed. So, we began to study NEI interim report for 15 year ILRT interval extension. As previous analysis based on NUREG-1493, MACCS II (MELCOR Accident Consequence Code System) computer code was used for the risk analysis of the population, and the population dose was selected as a reference index for the risk evaluation

  9. A new paradigm for Aedes spp. surveillance using gravid ovipositing sticky trap and NS1 antigen test kit.

    Science.gov (United States)

    Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra

    2017-03-21

    Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.

  10. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  11. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    Science.gov (United States)

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  12. Surveillance Culture

    DEFF Research Database (Denmark)

    2017-01-01

    What does it mean to live in a world full of surveillance? In this documentary film, we take a look at everyday life in Denmark and how surveillance technologies and practices influence our norms and social behaviour. Researched and directed by Btihaj Ajana and Anders Albrechtslund....

  13. New precise value for the muon magnetic moment and sensitive test of the theory of the hfs interval in muonium

    International Nuclear Information System (INIS)

    Casperson, D.E.; Crane, T.W.; Denison, A.B.; Egan, P.O.; Hughes, V.W.; Mariam, F.G.; Orth, H.; Reist, H.W.; Souder, P.A.; Stambaugh, R.D.; Thompson, P.A.; zu Putlitz, G.

    1977-01-01

    Measurements of Zeeman transitions in the ground state of muonium at strong magnetic field have yielded values for the hfs interval, Δν = 4463 302.35(52) kHz (0.12 ppm) and for the muon magnetic moment, μ/sub μ//μ/sub p/ = 3.183 3403(44) (1.4 ppm), fo considerably higher precision than previous results. The theoretical expression for Δν, including our measured value of μ/sub μ//μ/sub p/, disagrees with the experimental value by 2.5 standard deviations. The electronic g/sub J/ density shift for muonium in Kr has been measured

  14. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    Science.gov (United States)

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  15. Extension of Surveillance Test Interval of Safety Injection Pump for APR-1400 Reactors to Improve Reliability and Availability of the Pump

    Energy Technology Data Exchange (ETDEWEB)

    Osama, A. Rezk; Jung, J. C.; Lee, Yong-Kwan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-10-15

    The safety features function to localize, control, mitigate, and terminate such incidents and to hold exposure levels below applicable limits. The safety injection system is comprised of four independent mechanical trains without any tie line among the injection paths and two electrical divisions. Each train has one active Safety Injection Pump (SIP) and one passive Safety Injection Tank (SIT) equipped with a Fluidic Device (FD), each train provides 50% of the minimum injection flow rate for breaks larger than the size of a direct vessel injection line. For breaks equal to or smaller than the size of a direct vessel injection line, each train has 100% of the required capacity. The low pressure injection pumps with common header installed in the conventional design are eliminated, and the functions for safety injection and shutdown cooling are separated. The arrangement of safety injection system for APR-1400 as shown in figure (1). The results obtained in this work show that STI extensions for the SIS feasible without any unacceptable increase in the plant total risk, STI extensions are acceptable for safety injection system to provide plant operational flexibility in the performance of both corrective and preventive maintenance for the safety injection system.

  16. Audit of Helicobacter pylori Testing in Microbiology Laboratories in England: To Inform Compliance with NICE Guidance and the Feasibility of Routine Antimicrobial Resistance Surveillance

    Directory of Open Access Journals (Sweden)

    Rosalie Allison

    2016-01-01

    Full Text Available Introduction. The National Institute for Health and Clinical Excellence (NICE guidance recommends that dyspeptic patients are tested for Helicobacter pylori using a urea breath test, stool antigen test, or serology. Antibiotic resistance in H. pylori is globally increasing, but treatment in England is rarely guided by susceptibility testing or surveillance. Aims. To determine compliance of microbiology laboratories in England with NICE guidance and whether laboratories perform culture and antibiotic susceptibility testing (AST. Methods. In 2015, 170 accredited English microbiology laboratories were surveyed, by email. Results. 121/170 (71% laboratories responded; 96% provided H. pylori testing (78% on site. 94% provided H. pylori diagnosis using stool antigen; only four provided serology as their noninvasive test; 3/4 of these encouraged urea breath tests in their acute trusts. Only 22/94 (23% of the laboratories performed H. pylori cultures from gastric biopsies on site; 9/22 performed AST, but the vast majority processed less than one specimen/week. Conclusions. Only five laboratories in England do not comply with NICE guidance; these will need the guidance reinforced. National surveillance needs to be implemented; culture-based AST would need to be centralised. Moving forward, detection of resistance in H. pylori from stool specimens using molecular methods (PCR needs to be explored.

  17. Surveillance Pleasures

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    The notorious intensification and digitalization of surveillance technologies and practices in today’s society has brought about numerous changes. These changes have been widely noticed, described and discussed across many academic disciplines. However, the contexts of entertainment, play...

  18. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  19. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M.

    2011-11-01

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm 3 in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  20. Models and procedures for interval evaluating the results of control of knowledge in computer systems testing of Navy

    Directory of Open Access Journals (Sweden)

    D. A. Pechnikov

    2018-01-01

    Full Text Available To implement effective military and professional training of Navy specialists, a corresponding educational and material base is needed. As a result of the reduction in the 1990s in the branches of the military-industrial complex developing weapons and equipment for the Navy, the latest models of this technology are now produced not in batches, but in individual copies. The question of the production of training and training samples is not worth it at all. Under these conditions, only virtual analogues of military equipment and weapons, developed by means of information technology, i.e., training and training systems (TOS, can be considered as the only means capable of providing military-professional training. At the modern level of the development of information technologies, testing is the only universal technical means of monitoring the knowledge of students. Procedures for knowledge control in modern computer testing systems do not meet the requirements for them according to the following characteristics: 1 the absence of the possibility of evaluating the error of the test results; 2 the absence of the possibility of stopping testing when the specified reliability of its results is achieved. In order to effectively implement the means of operational criteria-based pedagogical control of knowledge in the process of training specialists of the Navy and to enable joint analysis and processing of evaluations of learning outcomes, it is advisable to implement the following practical recommendations: 1. Formulating the teacher's preferences system regarding the quality of trainee training and the teacher's preferences system in relation to The significance of single test tasks in the test should be considered as the most important The essential steps in preparing a test for practical use. 2. The teacher who first enters the input of his preference systems should check their actual compliance on a sample of 5-10 such test results that cover the full

  1. Country-wide surveillance of molecular markers of antimalarial drug resistance in Senegal by use of positive Malaria Rapid Diagnostic Tests

    DEFF Research Database (Denmark)

    Ndiaye, Magatte; Sow, Doudou; Nag, Sidsel

    2017-01-01

    of drug resistance. Therefore, surveillance of drug resistance in the malaria parasites is essential. The objective of this pilot study was to test the feasibility of routinely sampled malaria rapid diagnostic tests (RDTs) at a national scale to assess the temporal changes in the molecular profiles...... of antimalarial drug resistance markers of Plasmodium falciparum parasites. Overall, 9,549 positive malaria RDTs were collected from 14 health facilities across the country. A limited random set of RDTs were analyzed regarding Pfcrt gene polymorphisms at codon 72-76. Overall, a high but varied prevalence (> 50...

  2. Monitoring influenza activity in the United States: a comparison of traditional surveillance systems with Google Flu Trends.

    Directory of Open Access Journals (Sweden)

    Justin R Ortiz

    2011-04-01

    Full Text Available Google Flu Trends was developed to estimate US influenza-like illness (ILI rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections.Influenza activity data from 2003-04 through 2007-08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance, and US Influenza Virologic Surveillance System (CDC Virus Surveillance. Pearson's correlation coefficients with 95% confidence intervals (95% CI were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79. The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89. Most of the outlier observations in both comparisons were from the 2003-04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87 or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90.This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003-04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior.

  3. Monitoring Influenza Activity in the United States: A Comparison of Traditional Surveillance Systems with Google Flu Trends

    Science.gov (United States)

    Ortiz, Justin R.; Zhou, Hong; Shay, David K.; Neuzil, Kathleen M.; Fowlkes, Ashley L.; Goss, Christopher H.

    2011-01-01

    Background Google Flu Trends was developed to estimate US influenza-like illness (ILI) rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections. Methods and Findings Influenza activity data from 2003–04 through 2007–08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance), and US Influenza Virologic Surveillance System (CDC Virus Surveillance). Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79). The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89). Most of the outlier observations in both comparisons were from the 2003–04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87) or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90). Conclusions This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003–04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior. PMID:21556151

  4. Characteristics of patients patch tested in the European Surveillance System on Contact Allergies (ESSCA) network, 2009-2012

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Gefeller, Olaf; Giménez-Arnau, Ana

    2015-01-01

    from 63 530 consultations collected by 53 departments from 12 countries participating in the European Surveillance System on Contact Allergies (ESSCA) ( www.essca-dc.org) between 2009 and 2012. RESULTS: Considerable variation in the prevalence of the MOAHLFA factors between departments was found...... one department per country give valuable insights into the spectrum of contact allergy prevalence rates in that country, but are not as representative as national data pooled from several departments....

  5. Hepatocellular Carcinoma Surveillance Among Cirrhotic Patients With Commercial Health Insurance.

    Science.gov (United States)

    Goldberg, David S; Valderrama, Adriana; Kamalakar, Rajesh; Sansgiry, Sujit S; Babajanyan, Svetlana; Lewis, James D

    2016-03-01

    To evaluate hepatocellular carcinoma (HCC) surveillance rates among commercially insured patients, and evaluate factors associated with compliance with surveillance recommendations. Most HCC occurs in patients with cirrhosis. American Association for the Study of Liver Diseases and European Association for the Study of the Liver guidelines each recommend biannual HCC surveillance for cirrhotic patients to diagnose HCC at an early, curable stage. However, compliance with these guidelines in commercially insured patients is unknown. We used the Truven Health Analytics databases from 2006 to 2010, using January 1, 2006 as the anchor date for evaluating outcomes. The primary outcome was continuous surveillance measure, defined as the proportion of time "up-to-date" with surveillance (PTUDS), with the 6-month interval immediately following each ultrasound categorized as "up-to-date." During a median follow-up of 22.9 (interquartile range, 16.3 to 33.9) months among 8916 cirrhotic patients, the mean PTUDS was 0.34 (SD, 0.29), and the median was 0.31 (interquartile range, 0.03 to 0.52). These values increased only modestly with inclusion of serum alpha-fetoprotein testing, contrast-enhanced abdominal computed tomographic scans or magnetic resonance imagings, and/or extension of up-to-date time to 12 months. Being diagnosed by a nongastroenterology provider and increasing age were significantly associated with decreased HCC surveillance (Psurveillance (Psurveillance rates remained low. HCC surveillance rates in commercially insured at-risk patients remain poor despite formalized guidelines, highlighting the need to develop interventions to improve surveillance rates.

  6. Slug Test Characterization Results for Multi-Test/Depth Intervals Conducted During the Drilling of CERCLA Operable Unit OU ZP-1 Wells 299-W11-43, 299-W15-50, and 299-W18-16

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.; Newcomer, Darrell R.

    2010-06-21

    The following report presents test descriptions and analysis results for multiple, stress level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) ZP-1 wells: 299-W11-43 (C4694/Well H), 299-W15-50 (C4302/Well E), and 299-W18-16 (C4303/Well D). These wells are located within south-central region of the Hanford Site 200-West Area (Figure 1.1). The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OU ZP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.

  7. Slug Test Characterization Results for Multi-Test/Depth Intervals Conducted During the Drilling of CERCLA Operable Unit OU UP-1 Wells 299-W19-48, 699-30-66, and 699-36-70B

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.; Newcomer, Darrell R.

    2010-06-15

    This report presents test descriptions and analysis results for multiple, stress-level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) UP-1 wells: 299-W19-48 (C4300/Well K), 699-30-66 (C4298/Well R), and 699-36-70B (C4299/Well P). These wells are located within, adjacent to, and to the southeast of the Hanford Site 200-West Area. The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OU UP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.

  8. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (Capsule 2) of Ulchin Nuclear Power Plant Unit 4

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2007-04-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin Unit 4 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.306E+18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.918 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.615E+18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 8.478E+18 and 1.673E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin Unit 4 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  9. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (CAPSULE 2) of Ulchin Nuclear Power Plant Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2006-12-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.674E 18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.920 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.913E 18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 9.249E 18 and 1.834E 19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  10. Improving the performance of the Egyptian second testing nuclear research reactor using interval type-2 fuzzy logic controller tuned by modified biogeography-based optimization

    Energy Technology Data Exchange (ETDEWEB)

    Sayed, M.M., E-mail: M.M.Sayed@ieee.org; Saad, M.S.; Emara, H.M.; Abou El-Zahab, E.E.

    2013-09-15

    Highlights: • A modified version of the BBO was proposed. • A novel method for interval type-2 FLC design tuned by MBBO was proposed. • The performance of the ETRR-2 was improved by using IT2FLC tuned by MBBO. -- Abstract: Power stabilization is a critical issue in nuclear reactors. The conventional proportional derivative (PD) controller is currently used in the Egyptian second testing research reactor (ETRR-2). In this paper, we propose a modified biogeography-based optimization (MBBO) algorithm to design the interval type-2 fuzzy logic controller (IT2FLC) to improve the performance of the Egyptian second testing research reactor (ETRR-2). Biogeography-based optimization (BBO) is a novel evolutionary algorithm that is based on the mathematical models of biogeography. Biogeography is the study of the geographical distribution of biological organisms. In the BBO model, problem solutions are represented as islands, and the sharing of features between solutions is represented as immigration and emigration between the islands. A modified version of the BBO is applied to design the IT2FLC to get the optimal parameters of the membership functions of the controller. We test the optimal IT2FLC obtained by modified biogeography-based optimization (MBBO) using the integral square error (ISE) and is compared with the currently used PD controller.

  11. Influenza surveillance

    Directory of Open Access Journals (Sweden)

    Karolina Bednarska

    2016-04-01

    Full Text Available Influenza surveillance was established in 1947. From this moment WHO (World Health Organization has been coordinating international cooperation, with a goal of monitoring influenza virus activity, effective diagnostic of the circulating viruses and informing society about epidemics or pandemics, as well as about emergence of new subtypes of influenza virus type A. Influenza surveillance is an important task, because it enables people to prepare themselves for battle with the virus that is constantly mutating, what leads to circulation of new and often more virulent strains of influenza in human population. As vaccination is the most effective method of fighting the virus, one of the major tasks of GISRS is developing an optimal antigenic composition of the vaccine for the current epidemic season. European Influenza Surveillance Network (EISN has also developed over the years. EISN is running integrated epidemiological and virological influenza surveillance, to provide appropriate data to public health experts in member countries, to enable them undertaking relevant activities based on the current information about influenza activity. In close cooperation with GISRS and EISN are National Influenza Centres - national institutions designated by the Ministry of Health in each country.

  12. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the

  13. Surveillance of transmitted HIV drug resistance using matched plasma and dried blood spot specimens from voluntary counseling and testing sites in Ho Chi Minh City, Vietnam, 2007-2008.

    Science.gov (United States)

    Duc, Nguyen Bui; Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-05-01

    During 2007-2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%-15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18-21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs.

  14. Surveillance of antibiotic resistance

    Science.gov (United States)

    Johnson, Alan P.

    2015-01-01

    Surveillance involves the collection and analysis of data for the detection and monitoring of threats to public health. Surveillance should also inform as to the epidemiology of the threat and its burden in the population. A further key component of surveillance is the timely feedback of data to stakeholders with a view to generating action aimed at reducing or preventing the public health threat being monitored. Surveillance of antibiotic resistance involves the collection of antibiotic susceptibility test results undertaken by microbiology laboratories on bacteria isolated from clinical samples sent for investigation. Correlation of these data with demographic and clinical data for the patient populations from whom the pathogens were isolated gives insight into the underlying epidemiology and facilitates the formulation of rational interventions aimed at reducing the burden of resistance. This article describes a range of surveillance activities that have been undertaken in the UK over a number of years, together with current interventions being implemented. These activities are not only of national importance but form part of the international response to the global threat posed by antibiotic resistance. PMID:25918439

  15. Sensitivity and specificity of normality tests and consequences on reference interval accuracy at small sample size: a computer-simulation study.

    Science.gov (United States)

    Le Boedec, Kevin

    2016-12-01

    According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.

  16. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  17. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  18. Rinderpest surveillance

    International Nuclear Information System (INIS)

    2003-01-01

    Rinderpest is probably the most lethal virus disease of cattle and buffalo and can destroy whole populations; damaging economies; undermining food security and ruining the livelihood of farmers and pastoralists. The disease can be eradicated by vaccination and control of livestock movement. The Department of Technical Co-operation is sponsoring a programme, with technical support from the Joint FAO/IAEA Division to provide advice, training and materials to thirteen states through the 'Support for Rinderpest Surveillance in West Asia' project. (IAEA)

  19. Health surveillance

    International Nuclear Information System (INIS)

    1981-01-01

    The Code includes a number of requirements for the health surveillance of employees associated with the mining and milling of radioactive ores. This guideline is particularly directed at determining the level of fitness of employees and prospective employees, detecting any symptom which might contraindicate exposure to the environment encountered in mine/mill situations, examination of any employee who may have been exposed to radiation in excess of defined limits and the accumulation and provision of data on the health of employees

  20. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  1. Exploring the utility of cardiorespiratory fitness as a population health surveillance indicator for children and youth: An international analysis of results from the 20-m shuttle run test.

    Science.gov (United States)

    Lang, Justin J

    2018-02-01

    Emerging evidence has demonstrated the strong link between cardiorespiratory fitness and multiple aspects of health (i.e., physiological, physical, psychosocial, cognitive), independent of physical activity, among school-aged children and youth. Cardiorespiratory fitness is a trait that does not vary substantially from day-to-day, and provides an indication of recent physical activity levels, making it an important possible indicator of population health. Thus, the objective of this dissertation was to investigate the utility of cardiorespiratory fitness, measured using the 20-m shuttle run test, as a broad, holistic health indicator for population health surveillance among children and youth. To achieve this objective we completed 7 manuscripts, all prepared for submission to peer-reviewed, scientific journals: (1) Systematic review of the relationship between 20-m shuttle run performance and health indicators among children and youth. (2) Review of criterion-referenced standards for cardiorespiratory fitness: what percentage of 1 142 026 international children and youth are apparently healthy? (3) Cardiorespiratory fitness is associated with physical literacy in a large sample of Canadian children aged 8 to 12 years. (4) International variability in 20-m shuttle run performance in children and youth: Who are the fittest from a 50-country comparison? A systematic review with pooling of aggregate results. (5) Making a case for cardiorespiratory fitness surveillance among children and youth. (6) International normative 20-m shuttle run values from 1 142 026 children and youth representing 50 countries. (7) Temporal trends in the cardiorespiratory fitness of children and adolescents representing 19 high-income and upper middle-income countries between 1981 and 2014. Combined, this dissertation provides support for the importance of cardiorespiratory fitness for health surveillance among school-aged children and youth. Results from the international analysis

  2. Final report for the 5th surveillance test of the reactor pressure vessel material (capsule Y) of Yonggwang Nuclear Power Plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sam Lai; Kim, ByoungChul; Chang, Kee Ok (and others)

    2006-02-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X, W and Y are 5.777E+18, 1.5371E+19, 3.7634E+19, 4.3045E+19, and 4.8662E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.953 for the 1st through 5th testing and the calculational uncertainty,7.2% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.659E+19n/cm{sup 2} based on the end of 13th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 48, 56 and 64EFPY would reach 3.625E+19, 5.293E+19, 6.127E+19 and 6.960E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the Pressurized Thermal Shock(PTS) during the operation until design life.

  3. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  4. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  5. Surveillance of the environmental radioactivity

    International Nuclear Information System (INIS)

    Schneider, Th.; Gitzinger, C.; Jaunet, P.; Eberbach, F.; Clavel, B.; Hemidy, P.Y.; Perrier, G.; Kiper, Ch.; Peres, J.M.; Josset, M.; Calvez, M.; Leclerc, M.; Leclerc, E.; Aubert, C.; Levelut, M.N.; Debayle, Ch.; Mayer, St.; Renaud, Ph.; Leprieur, F.; Petitfrere, M.; Catelinois, O.; Monfort, M.; Baron, Y.; Target, A.

    2008-01-01

    The objective of these days was to present the organisation of the surveillance of the environmental radioactivity and to allow an experience sharing and a dialog on this subject between the different actors of the radiation protection in france. The different presentations were as follow: evolution and stakes of the surveillance of radioactivity in environment; the part of the European commission, regulatory aspects; the implementation of the surveillance: the case of Germany; Strategy and logic of environmental surveillance around the EDF national centers of energy production; environmental surveillance: F.B.F.C. site of Romans on Isere; steps of the implementation 'analysis for release decree at the F.B.F.C./C.E.R.C.A. laboratory of Romans; I.R.S.N. and the environmental surveillance: situation and perspectives; the part of a non institutional actor, the citizenship surveillance done by A.C.R.O.; harmonization of sampling methods: the results of inter operators G.T. sampling; sustainable observatory of environment: data traceability and samples conservation; inter laboratories tests of radioactivity measurements; national network of environmental radioactivity measurement: laboratories agreements; the networks of environmental radioactivity telemetry: modernization positioning; programme of observation and surveillance of surface environment and installations of the H.A.-M.A.V.L. project (high activity and long life medium activity); Evolution of radionuclides concentration in environment and adaptation of measurements techniques to the surveillance needs; the national network of radioactivity measurement in environment; modes of data restoration of surveillance: the results of the Loire environment pilot action; method of sanitary impacts estimation in the area of ionizing radiations; the radiological impact of atmospheric nuclear tests in French Polynesia; validation of models by the measure; network of measurement and alert management of the atmospheric

  6. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. H5N1-SeroDetect EIA and rapid test: a novel differential diagnostic assay for serodiagnosis of H5N1 infections and surveillance.

    Science.gov (United States)

    Khurana, Surender; Sasono, Pretty; Fox, Annette; Nguyen, Van Kinh; Le, Quynh Mai; Pham, Quang Thai; Nguyen, Tran Hien; Nguyen, Thanh Liem; Horby, Peter; Golding, Hana

    2011-12-01

    Continuing evolution of highly pathogenic (HP) H5N1 influenza viruses in wild birds with transmission to domestic poultry and humans poses a pandemic threat. There is an urgent need for a simple and rapid serological diagnostic assay which can differentiate between antibodies to seasonal and H5N1 strains and that could provide surveillance tools not dependent on virus isolation and nucleic acid technologies. Here we describe the establishment of H5N1 SeroDetect enzyme-linked immunosorbent assay (ELISA) and rapid test assays based on three peptides in HA2 (488-516), PB1-F2 (2-75), and M2e (2-24) that are highly conserved within H5N1 strains. These peptides were identified by antibody repertoire analyses of H5N1 influenza survivors in Vietnam using whole-genome-fragment phage display libraries (GFPDLs). To date, both platforms have demonstrated high levels of sensitivity and specificity in detecting H5N1 infections (clade 1 and clade 2.3.4) in Vietnamese patients as early as 7 days and up to several years postinfection. H5N1 virus-uninfected individuals in Vietnam and the United States, including subjects vaccinated with seasonal influenza vaccines or with confirmed seasonal virus infections, did not react in the H5N1-SeroDetect assays. Moreover, sera from individuals vaccinated with H5N1 subunit vaccine with moderate anti-H5N1 neutralizing antibody titers did not react positively in the H5N1-SeroDetect ELISA or rapid test assays. The simple H5N1-SeroDetect ELISA and rapid tests could provide an important tool for large-scale surveillance for potential exposure to HP H5N1 strains in both humans and birds.

  8. Five-year risk of interval-invasive second breast cancer.

    Science.gov (United States)

    Lee, Janie M; Buist, Diana S M; Houssami, Nehmat; Dowling, Emily C; Halpern, Elkan F; Gazelle, G Scott; Lehman, Constance D; Henderson, Louise M; Hubbard, Rebecca A

    2015-07-01

    Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. © The Author 2015. Published by Oxford University Press. All rights reserved

  9. Nutritional surveillance.

    Science.gov (United States)

    Mason, J B; Mitchell, J T

    1983-01-01

    The concept of nutritional surveillance is derived from disease surveillance, and means "to watch over nutrition, in order to make decisions that lead to improvements in nutrition in populations". Three distinct objectives have been defined for surveillance systems, primarily in relation to problems of malnutrition in developing countries: to aid long-term planning in health and development; to provide input for programme management and evaluation; and to give timely warning of the need for intervention to prevent critical deteriorations in food consumption. Decisions affecting nutrition are made at various administrative levels, and the uses of different types of nutritional surveillance information can be related to national policies, development programmes, public health and nutrition programmes, and timely warning and intervention programmes. The information should answer specific questions, for example concerning the nutritional status and trends of particular population groups.Defining the uses and users of the information is the first essential step in designing a system; this is illustrated with reference to agricultural and rural development planning, the health sector, and nutrition and social welfare programmes. The most usual data outputs are nutritional outcome indicators (e.g., prevalence of malnutrition among preschool children), disaggregated by descriptive or classifying variables, of which the commonest is simply administrative area. Often, additional "status" indicators, such as quality of housing or water supply, are presented at the same time. On the other hand, timely warning requires earlier indicators of the possibility of nutritional deterioration, and agricultural indicators are often the most appropriate.DATA COME FROM TWO MAIN TYPES OF SOURCE: administrative (e.g., clinics and schools) and household sample surveys. Each source has its own advantages and disadvantages: for example, administrative data often already exist, and can be

  10. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  11. HIV intertest interval among MSM in King County, Washington.

    Science.gov (United States)

    Katz, David A; Dombrowski, Julia C; Swanson, Fred; Buskin, Susan E; Golden, Matthew R; Stekler, Joanne D

    2013-02-01

    The authors examined temporal trends and correlates of HIV testing frequency among men who have sex with men (MSM) in King County, Washington. The authors evaluated data from MSM testing for HIV at the Public Health-Seattle & King County (PHSKC) STD Clinic and Gay City Health Project (GCHP) and testing history data from MSM in PHSKC HIV surveillance. The intertest interval (ITI) was defined as the number of days between the last negative HIV test and the current testing visit or first positive test. Correlates of the log(10)-transformed ITI were determined using generalised estimating equations linear regression. Between 2003 and 2010, the median ITI among MSM seeking HIV testing at the STD Clinic and GCHP were 215 (IQR: 124-409) and 257 (IQR: 148-503) days, respectively. In multivariate analyses, younger age, having only male partners and reporting ≥10 male sex partners in the last year were associated with shorter ITIs at both testing sites (pGCHP attendees, having a regular healthcare provider, seeking a test as part of a regular schedule and inhaled nitrite use in the last year were also associated with shorter ITIs (pGCHP (median 359 vs 255 days, p=0.02). Although MSM in King County appear to be testing at frequent intervals, further efforts are needed to reduce the time that HIV-infected persons are unaware of their status.

  12. Reactor Vessel Surveillance Program for Advanced Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyeong-Hoon; Kim, Tae-Wan; Lee, Gyu-Mahn; Kim, Jong-Wook; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-15

    This report provides the design requirements of an integral type reactor vessel surveillance program for an integral type reactor in accordance with the requirements of Korean MEST (Ministry of Education, Science and Technology Development) Notice 2008-18. This report covers the requirements for the design of surveillance capsule assemblies including their test specimens, test block materials, handling tools, and monitors of the surveillance capsule neutron fluence and temperature. In addition, this report provides design requirements for the program for irradiation surveillance of reactor vessel materials, a layout of specimens and monitors in the surveillance capsule, procedures of installation and retrieval of the surveillance capsule assemblies, and the layout of the surveillance capsule assemblies in the reactor.

  13. Tamper indicating radiation surveillance instrumentation

    International Nuclear Information System (INIS)

    Chambers, W.H.; Ney, J.F.

    1975-01-01

    Prototype personnel and shipping dock portal monitors suitable for unattended use were fabricated and tested. The requirement for continuous operation with only periodic inspection along with a desire for minimum costs and minimum interference with normal plant operation imposed unique design constraints. The design, operation, and performance of the detection and data recording instrumentation are described, as well as the tamper indicating techniques required to protect the collected data. The essential elements of either of the two instruments include a gamma detector array, signal conditioning electronics, digital alarm logic circuitry, power supplies, a microwave occupancy monitor, surveillance camera, irreversible electromechanical counters, and the appropriate tamper indicating envelope protecting these elements. Attempts to penetrate the tamper indicating envelope require material removal, and undetectable repair is very difficult, if not impossible. The techniques for joining major subassemblies and providing unique seals are also described. The personnel doorway uses a double pole array of NaI(Tl) detectors, and outputs are taken from a single channel pulse height analyzer with a window set at 60 to 250 keV and the lower level discriminator at greater than 60 keV. A sliding interval counter is used to make comparisons to an accumulated background at the 4sigma level. Logic design, sensitivity for special nuclear materials, false alarm data, and test procedures are described in detail. The shipping dock monitor had different design constraints and therefore uses a single, long, cylindrical plastic scintillator. Some differences in signal conditioning and processing are also described. (auth)

  14. Interval selection with machine-dependent intervals

    OpenAIRE

    Bohmova K.; Disser Y.; Mihalak M.; Widmayer P.

    2013-01-01

    We study an offline interval scheduling problem where every job has exactly one associated interval on every machine. To schedule a set of jobs, exactly one of the intervals associated with each job must be selected, and the intervals selected on the same machine must not intersect.We show that deciding whether all jobs can be scheduled is NP-complete already in various simple cases. In particular, by showing the NP-completeness for the case when all the intervals associated with the same job...

  15. Nanostructural evolution in surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Toyama, T.; Nagai, Y.; Tang, Z.; Hasegawa, M.; Almazouzi, A.; Walle, E. van; Gerard, R.

    2007-01-01

    The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of in-service commercial nuclear reactor pressure vessel steel welds of Doel-1 and Doel-2 are revealed by combining the three-dimensional local electrode atom probe and positron annihilation techniques. In both medium (0.13 wt.%) and high (0.30 wt.%) Cu welds, the CRNPs are found to form readily at the very beginning of the reactor lifetime. Thereafter, during the subsequent 30 years of operation, the residual Cu concentration in the matrix shows a slight decrease while the CRNPs coarsen. On the other hand, small vacancy clusters of V 3 -V 4 start appearing after the initial Cu precipitation and accumulate steadily with increasing neutron dose. The observed nanostructural evolution is shown to provide unique and fundamental information about the mechanisms of the irradiation-induced embrittlement of these specific materials

  16. Development of methodologies for optimization of surveillance testing and maintenance of safety related equipment at NPPs. Report of a research coordination meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    This report summarizes the results of the first meeting of the Coordinated Research Programme (CRP) on Development of Methodologies for Optimization of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs, held at the Agency Headquarters in Vienna, from 16 to 20 December 1996. The purpose of this Research Coordination Meeting (RCM) was that all Chief Scientific Investigators of the groups participating in the CRP presented an outline of their proposed research projects. Additionally, the participants discussed the objective, scope, work plan and information channels of the CRP in detail. Based on these presentations and discussions, the entire project plan was updated, completed and included in this report. This report represents a common agreed project work plan for the CRP. Refs, figs, tabs.

  17. Analyses and results from standard surveillance programmes of WWER 440/V-213C reactor pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Falcnik, M; Brumovsky, M; Pav, T [Czech Nuclear Society, Prague (Czech Republic)

    1994-12-31

    In Czech and Slovak republics, six units of WWER 440/C type reactors are monitored by surveillance specimens programmes; the specimens are determined for static tensile testing, impact notch toughness testing and fracture toughness evaluation. Results of mechanical properties of these specimens after irradiation in intervals between 1 and 5 years of operation, are summarized and discussed with respect to the effect of individual heats and welded joints, radiation embrittlement, and annealing recovery. (authors). 3 refs., 11 figs., 2 tabs.

  18. Statistical adjustment of culture-independent diagnostic tests for trend analysis in the Foodborne Diseases Active Surveillance Network (FoodNet), USA.

    Science.gov (United States)

    Gu, Weidong; Dutta, Vikrant; Patrick, Mary; Bruce, Beau B; Geissler, Aimee; Huang, Jennifer; Fitzgerald, Collette; Henao, Olga

    2018-03-19

    Culture-independent diagnostic tests (CIDTs) are increasingly used to diagnose Campylobacter infection in the Foodborne Diseases Active Surveillance Network (FoodNet). Because CIDTs have different performance characteristics compared with culture, which has been used historically and is still used to diagnose campylobacteriosis, adjustment of cases diagnosed by CIDT is needed to compare with culture-confirmed cases for monitoring incidence trends. We identified the necessary parameters for CIDT adjustment using culture as the gold standard, and derived formulas to calculate positive predictive values (PPVs). We conducted a literature review and meta-analysis to examine the variability in CIDT performance and Campylobacter prevalence applicable to FoodNet sites. We then developed a Monte Carlo method to estimate test-type and site-specific PPVs with their associated uncertainties. The uncertainty in our estimated PPVs was largely derived from uncertainty about the specificity of CIDTs and low prevalence of Campylobacter in tested samples. Stable CIDT-adjusted incidences of Campylobacter cases from 2012 to 2015 were observed compared with a decline in culture-confirmed incidence. We highlight the lack of data on the total numbers of tested samples as one of main limitations for CIDT adjustment. Our results demonstrate the importance of adjusting CIDTs for understanding trends in Campylobacter incidence in FoodNet.

  19. Surveillance and Critical Theory

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2015-09-01

    Full Text Available In this comment, the author reflects on surveillance from a critical theory approach, his involvement in surveillance research and projects, and the status of the study of surveillance. The comment ascertains a lack of critical thinking about surveillance, questions the existence of something called “surveillance studies” as opposed to a critical theory of society, and reflects on issues such as Edward Snowden’s revelations, and Foucault and Marx in the context of surveillance.

  20. Unexpectedly high leprosy seroprevalence detected using a random surveillance strategy in midwestern Brazil: A comparison of ELISA and a rapid diagnostic test.

    Science.gov (United States)

    Frade, Marco Andrey C; de Paula, Natália A; Gomes, Ciro M; Vernal, Sebastian; Bernardes Filho, Fred; Lugão, Helena B; de Abreu, Marilda M M; Botini, Patrícia; Duthie, Malcolm S; Spencer, John S; Soares, Rosa Castália F R; Foss, Norma T

    2017-02-01

    Leprosy diagnosis is mainly based on clinical evaluation, although this approach is difficult, especially for untrained physicians. We conducted a temporary campaign to detect previously unknown leprosy cases in midwestern Brazil and to compare the performance of different serological tests. A mobile clinic was stationed at the main bus terminal in Brasília, Brazil. Volunteers were quizzed and given a clinical exam to allow categorization as either patients, known contacts of patients or non-contacts, and blood was collected to determine anti-PGL-I and anti-LID-1 antibody titers by ELISA and by the NDO-LID rapid test. New cases of leprosy and the impact of performing this broad random surveillance strategy were evaluated. Accuracy values and concordance between the test results were evaluated among all groups. Four hundred thirty-four individuals were evaluated, and 44 (10.1%) were diagnosed with leprosy. Borderline forms were the most frequent presentation. Both tests presented higher positivity in those individuals with multibacillary disease. Serological tests demonstrated specificities arround 70% for anti-PGL-1 and anti-LID ELISA; and arround 40% for NDO-LID. Sensitivities ranged from 48 to 62%. A substantial agreement between NDO-LID and ELISA with concomitant positive results was found within leprosy patients (Kappa index = 0.79 CI95% 0.36-1.22). The unexpectedly high leprosy prevalence in this population indicates ongoing community-based exposure to Mycobacterium leprae antigens and high rates of subclinical infection. All tests showed low specificity and sensitivity values and therefore cannot be considered for use as stand-alone diagnostics. Rather, considering their positivity among MB patients and non-patients, these tests can be considered effective tools for screening and identifying individuals at high risk who might benefit from regular monitoring.

  1. Clinical Microbiology Laboratories' Adoption of Culture-Independent Diagnostic Tests Is a Threat to Foodborne-Disease Surveillance in the United States.

    Science.gov (United States)

    Shea, Shari; Kubota, Kristy A; Maguire, Hugh; Gladbach, Stephen; Woron, Amy; Atkinson-Dunn, Robyn; Couturier, Marc Roger; Miller, Melissa B

    2017-01-01

    INTRODUCTIONIn November 2015, the Centers for Disease Control and Prevention (CDC) sent a letter to state and territorial epidemiologists, state and territorial public health laboratory directors, and state and territorial health officials. In this letter, culture-independent diagnostic tests (CIDTs) for detection of enteric pathogens were characterized as "a serious and current threat to public health surveillance, particularly for Shiga toxin-producing Escherichia coli (STEC) and Salmonella" The document says CDC and its public health partners are approaching this issue, in part, by "reviewing regulatory authority in public health agencies to require culture isolates or specimen submission if CIDTs are used." Large-scale foodborne outbreaks are a continuing threat to public health, and tracking these outbreaks is an important tool in shortening them and developing strategies to prevent them. It is clear that the use of CIDTs for enteric pathogen detection, including both antigen detection and multiplex nucleic acid amplification techniques, is becoming more widespread. Furthermore, some clinical microbiology laboratories will resist the mandate to require submission of culture isolates, since it will likely not improve patient outcomes but may add significant costs. Specimen submission would be less expensive and time-consuming for clinical laboratories; however, this approach would be burdensome for public health laboratories, since those laboratories would need to perform culture isolation prior to typing. Shari Shea and Kristy Kubota from the Association of Public Health Laboratories, along with state public health laboratory officials from Colorado, Missouri, Tennessee, and Utah, will explain the public health laboratories' perspective on why having access to isolates of enteric pathogens is essential for public health surveillance, detection, and tracking of outbreaks and offer potential workable solutions which will allow them to do this. Marc Couturier of

  2. Results from 15years of quality surveillance for a National Indigenous Point-of-Care Testing Program for diabetes.

    Science.gov (United States)

    Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina

    2017-12-01

    Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012

    DEFF Research Database (Denmark)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A

    2015-01-01

    BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data of patie......BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data...... of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. RESULTS......: Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance...

  4. Zero- vs. one-dimensional, parametric vs. non-parametric, and confidence interval vs. hypothesis testing procedures in one-dimensional biomechanical trajectory analysis.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2015-05-01

    Biomechanical processes are often manifested as one-dimensional (1D) trajectories. It has been shown that 1D confidence intervals (CIs) are biased when based on 0D statistical procedures, and the non-parametric 1D bootstrap CI has emerged in the Biomechanics literature as a viable solution. The primary purpose of this paper was to clarify that, for 1D biomechanics datasets, the distinction between 0D and 1D methods is much more important than the distinction between parametric and non-parametric procedures. A secondary purpose was to demonstrate that a parametric equivalent to the 1D bootstrap exists in the form of a random field theory (RFT) correction for multiple comparisons. To emphasize these points we analyzed six datasets consisting of force and kinematic trajectories in one-sample, paired, two-sample and regression designs. Results showed, first, that the 1D bootstrap and other 1D non-parametric CIs were qualitatively identical to RFT CIs, and all were very different from 0D CIs. Second, 1D parametric and 1D non-parametric hypothesis testing results were qualitatively identical for all six datasets. Last, we highlight the limitations of 1D CIs by demonstrating that they are complex, design-dependent, and thus non-generalizable. These results suggest that (i) analyses of 1D data based on 0D models of randomness are generally biased unless one explicitly identifies 0D variables before the experiment, and (ii) parametric and non-parametric 1D hypothesis testing provide an unambiguous framework for analysis when one׳s hypothesis explicitly or implicitly pertains to whole 1D trajectories. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. A comparison of confidence/credible interval methods for the area under the ROC curve for continuous diagnostic tests with small sample size.

    Science.gov (United States)

    Feng, Dai; Cortese, Giuliana; Baumgartner, Richard

    2017-12-01

    The receiver operating characteristic (ROC) curve is frequently used as a measure of accuracy of continuous markers in diagnostic tests. The area under the ROC curve (AUC) is arguably the most widely used summary index for the ROC curve. Although the small sample size scenario is common in medical tests, a comprehensive study of small sample size properties of various methods for the construction of the confidence/credible interval (CI) for the AUC has been by and large missing in the literature. In this paper, we describe and compare 29 non-parametric and parametric methods for the construction of the CI for the AUC when the number of available observations is small. The methods considered include not only those that have been widely adopted, but also those that have been less frequently mentioned or, to our knowledge, never applied to the AUC context. To compare different methods, we carried out a simulation study with data generated from binormal models with equal and unequal variances and from exponential models with various parameters and with equal and unequal small sample sizes. We found that the larger the true AUC value and the smaller the sample size, the larger the discrepancy among the results of different approaches. When the model is correctly specified, the parametric approaches tend to outperform the non-parametric ones. Moreover, in the non-parametric domain, we found that a method based on the Mann-Whitney statistic is in general superior to the others. We further elucidate potential issues and provide possible solutions to along with general guidance on the CI construction for the AUC when the sample size is small. Finally, we illustrate the utility of different methods through real life examples.

  6. Relationship between a Centers for Disease Control and Prevention expanded HIV testing initiative and past-year testing by race/ethnicity: a multilevel analysis of the Behavioral Risk Factor Surveillance System.

    Science.gov (United States)

    Gaines, Tommi L; Caldwell, Julia T; Ford, Chandra L; Mulatu, Mesfin S; Godette, Dionne C

    2016-01-01

    The Centers for Disease Control and Prevention's (CDC) expanded testing initiative (ETI) aims to bolster HIV testing among populations disproportionately affected by the HIV epidemic by providing additional funding to health departments serving these communities. ETI prioritizes testing in clinical settings; therefore, we examined the relationship between state-level ETI participation and past-year HIV testing among a racially/ethnically diverse sample of adult respondents to the 2012 Behavioral Risk Factor Surveillance System who accessed health services within the 12 months prior to being interviewed. Controlling for individual- and state-level characteristics in a multilevel logistic regression model, ETI participation was independently and positively associated with past-year testing, but this association varied by race/ethnicity. Hispanics had higher odds (adjusted odds ratio [AOR]: 1.49; 95% CI: 1.11-2.02) and American Indian/Alaska Natives had lower odds (AOR: 0.66; 95% CI: 0.43-0.99) of testing if they resided in states with (vs. without) ETI participation. State-level ETI participation did not significantly alter past-year testing among other racial/ethnic groups. Prioritizing public health resources in states most affected by HIV can improve testing patterns, but other mechanisms likely influence which racial/ethnic groups undergo testing.

  7. The modification and evaluation of an ELISA test for the surveillance of Mycobacterium avium subsp. paratuberculosis infection in wild ruminants

    Directory of Open Access Journals (Sweden)

    Pruvot Mathieu

    2013-01-01

    Full Text Available Abstract Background Enzyme-linked immunosorbent assay (ELISA is often used to test wildlife samples for Mycobacterium avium subsp. paratuberculosis (MAP infection. However, commercially available kits are only validated for use with domestic ruminant species. A literature review was performed to document the current use of MAP serum ELISA in wild and semi-domestic ruminants. We then modified and evaluated a commercial ELISA kit (IDEXX Mycobacterium paratuberculosis Antibody Test Kit for use with species for which it was not originally developed: elk (Cervus elaphus, bison (Bison bison and caribou (Rangifer tarandus. We tested the affinity of different conjugates for immunoglobulin G (IgG isolated from these species, performed checkerboard tests to determine the optimal dilutions of samples and conjugates, and established cut-off values using two different methods: a Receiver Operational Curve on a panel of known samples for elk, and an alternate method involving a panel of unknown serum samples for the three species. Results We found that the anti-bovine conjugate included in the IDEXX ELISA kit has limited affinity for elk, bison, and caribou IgG. Protein G showed good affinity for IgG of all three species, while anti-deer conjugate also bound elk and caribou IgG. Using Protein G with elk serum, a cut-off sample-to-positive (S/P value of 0.22 was selected, resulting in a sensitivity and specificity of 73% and 90%, respectively, whereas, using an anti-deer conjugate with elk serum, an S/P cut-off value of 0.29 gave a sensitivity of 68%, with 100% specificity. Cut-off values for bison and caribou using the Protein G conjugate were 0.17 and 0.25 respectively. Conclusions Due to incomplete reporting and a lack of test validation, it is difficult to critically appraise results of many sero-surveys that have previously been done for MAP in wildlife. Commercial ELISA kits may have limited or no capacity to detect antibodies from species other than for

  8. Safety of laboratory analyzers for infection testing - results of the market surveillance by the BfArM until end 2007

    Directory of Open Access Journals (Sweden)

    Siekmeier R

    2009-12-01

    Full Text Available Abstract The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM is the responsible CA for most IVD, with a small subset of IVD for immune hematological and infectiological testing as well as tissue typing as specified in Annex II of the Directive, being within the responsibility of the Paul-Ehrlich-Institute (PEI. In this study, all issues regarding laboratory analyzers for infection testing and their consumables, but not reagents, kits and general culture media, reported to the BfArM between begin 1999 and end of 2007 were analyzed in respect to the sources of report, the underlying product failure and the performed corrective actions. Within the observation period a total of 1471 reports for IVD were received of which 73 related to the IVD for infection testing were included in our study. Reports were predominantly received from manufacturers (56 and competent authorities (15. Affected products were most frequently those for immunological analysis (42 whereas those based on culturing techniques (17 and molecular biological techniques (14 played only minor roles. In all these groups, laboratory analyzers (55 were more frequently affected than their consumables (18. Investigations of the manufacturers were able to identify the underlying root causes of product failures in 62 cases (84.9%. In 2 cases (2.7% the root cause remained unclear and in 9 cases (12.3% a product failure was excluded or a user error was the underlying cause. Product failures in laboratory analyzers were most frequently caused by software errors (31 and constructional faults (8 whereas the predominant cause of product failure in consumables were errors in production and

  9. HIV testing and intimate partner violence among non-pregnant women in 15 US states/territories: findings from behavioral risk factor surveillance system survey data.

    Science.gov (United States)

    Nasrullah, Muazzam; Oraka, Emeka; Breiding, Mathew J; Chavez, Pollyanna R

    2013-09-01

    Intimate partner violence (IPV) has been shown to be associated with higher rates of HIV infection among women, underscoring the importance of encouraging IPV victims to receive HIV testing. However, we do not know how much HIV testing behavior is influenced by IPV victimization. The current study characterized the association between individual types of IPV and HIV testing in a large sample of non-pregnant women in 15 US states/territories. The 2005 Behavioral Risk Factor Surveillance System data were analyzed after restricting the sample to non-pregnant women. The dependent variable, whether a woman ever had an HIV test, was examined in relation to individual types of IPV victimization (threatened physical violence; attempted physical violence; completed physical violence; and unwanted sex). Associations between HIV testing and types of IPV were assessed using adjusted risk ratios (aRR) that controlled for demographics and HIV-related risk factors (intravenous drug use, sexually transmitted diseases, exchange sex, unprotected anal sex). Approximately 28.6 % of women reported ever having experienced IPV, and 52.8 % of these women reported being tested for HIV. Among women who had not experienced IPV, 32.9 % reported ever having been tested for HIV. HIV testing was associated with lifetime experience of threatened violence (aRR = 1.43; 95 % CI = 1.24-1.65), attempted violence (aRR = 1.43; 95 % CI = 1.20-1.69), completed physical violence (aRR = 1.30; 95 % CI = 1.13-1.48), and unwanted sex (aRR = 1.66; 95 % CI = 1.48-1.86). Women who experienced each type of IPV were more likely to have been ever tested for HIV compared to women with no IPV history. However, nearly half of those reporting IPV, even though at greater risk for HIV infection, had never been tested. Additional efforts are needed to address barriers to testing in this group.

  10. Surveillance of compliance with tobacco regulations in Örebro County, Sweden: a mixed methods study after the ban of test purchases.

    Science.gov (United States)

    Schölin, Lisa; Eriksson, Charli

    2012-02-15

    Tobacco has long been known to be one of the most common reasons for sickness and premature deaths in the world. An important aspect of tobacco use is the youth's access to tobacco, and surveillance visits are one way to make sure how retailers are complying with age limit in the tobacco law. In Örebro County, Sweden, a project to reinforce the tobacco legislation was carried out in 2009-2010. One part of the project was surveillance visits that were done according to three different themes, called thematic surveillance. This study is an evaluation of the results from thematic surveillance and has a mixed methods approach. The quantitative analyses concerns protocols from 217 surveillance visits, where questions were asked about three themes (self-monitoring programs; marketing; labeling of products and pricing). In addition, questionnaires filled out by six tobacco administrators who worked within the project were analyzed qualitatively by content analysis in order to study their perceptions and opinions of the project. This study shows that half of the visited retailers had self-monitoring programs. Lack of self-monitoring programs was significantly more common in smaller stores/kiosks and at restaurants. Further, the tobacco administrators who worked within the project perceived thematic surveillance as a good method for accomplishing better structure in surveillance work, but not as effective as purchase attempts (mystery shopping). Thematic surveillance was perceived as positive and the method was also regarded to be a good way to work with surveillance. However, the method could be developed further for optimal use and better effect at the retailers. It is clear that people who work with tobacco prevention at the local level in Örebro County want to use purchase attempts as a surveillance method, and that they believe that purchase attempts is the best way to make sure if store comply with the tobacco law.

  11. Anxiety, Culture, and Expectations: Oncologist-Perceived Factors Associated With Use of Nonrecommended Serum Tumor Marker Tests for Surveillance of Early-Stage Breast Cancer.

    Science.gov (United States)

    Hahn, Erin E; Munoz-Plaza, Corrine; Wang, Jianjin; Garcia Delgadillo, Jazmine; Schottinger, Joanne E; Mittman, Brian S; Gould, Michael K

    2017-01-01

    Breast cancer offers several opportunities for reducing use of ineffective practices based on American Society of Clinical Oncology guidelines. We assessed oncologist-perceived factors associated with use of one such practice-serum tumor markers for post-treatment breast cancer surveillance-focusing on medical oncologists with high, medium, or low test use. Using a mixed-methods design, we identified patients who had been treated for early-stage breast cancer diagnosed between January 1, 2009, and December 31, 2012, within Kaiser Permanente Southern California and calculated the number of tests ordered from January 1, 2010, to December 31, 2014. We identified oncologists with high, medium, or low use and subsequently performed semistructured interviews. We used patient satisfaction data to assess association between pattern of use and satisfaction score. We identified 7,363 patients, with 40,114 tests ordered. High-use oncologists were defined as those ordering at least one test annually for 35% of patients or more, low-use oncologists as those ordering at least one test for 5% of patients or less; 42% of oncologists were high, 27% low, and 31% medium users. We interviewed 17 oncologists: six high, eight low, and three medium users. Factors associated with high use included: perceived patient anxiety, oncologist anxiety, belief that there was nothing else to offer, concern about satisfaction, patient competition, peer use, and system barriers. Factors associated with low use included: beliefs about consequences (eg, causes harms) and medical center culture (eg, collective decision to follow guidelines). We found no association between satisfaction score and pattern of use. Barriers to deimplementation are numerous and complex. Traditional strategies of practice change alone are unlikely to be effective. Multifaceted, multilevel strategies deployed to address patient-, clinician-, and system-related barriers may be required.

  12. Choosing the correct empirical antibiotic for urinary tract infection in pediatric: Surveillance of antimicrobial susceptibility pattern of Escherichia coli by E-Test method.

    Science.gov (United States)

    Sedighi, Iraj; Solgi, Abbas; Amanati, Ali; Alikhani, Mohammad Yousef

    2014-12-01

    Urinary Tract Infections (UTIs) are of the most common bacterial diseases worldwide. We investigate the antibiotic susceptibility patterns of Escherichia coli (E. coli) strains isolated from pediatric patients with community acquired urinary tract infection (UTI) to find a clinical guidance for choosing a right empirical antibiotic in these patients. In this cross sectional study, 100 urine specimens which were positive for E. coli had been investigated for antibiotics susceptibility pattern. The susceptibility to Co-trimoxazol (25μg), Amikacin (30μg), Ceftriaxone (30μg), Nalidixic Acid (30μg), Cefixime (5μg), and Nitrofurantoin (300μg) tested with Disk diffusion agar and MIC determined with the E-test. Mean age of patients was 38 Months. Girls had greater proportion than boys (74 versus 26%). In Disk diffusion method, 26% of the isolates were susceptible to cotrimoxazole. Susceptibility to amikacin, ceftriaxone, nitrofurantoin, nalidixic acid and cefixime was 94%, 66%, 97%, 62% and 52%, respectively. By E-Test method and according to CLSI criteria susceptibility for co-trimoxazol, amikacin, ceftriaxone and nalidixic acid was 37%, 97%, 67% and 50%, respectively. The highest percentage of agreement between Disk diffusion and E-Test method was found for amikacin (96%) and the lowest percentage for co-trimoxazole (89%). Treatment failure, prolonged or repeated hospitalization, increased costs of care, and increased mortality are some consequence of bacterial resistance in UTIs. Misuse of antibiotics in each geographic location directly affects antibiotic resistance pattern. In the treatment of UTI, proper selection of antimicrobial agents should be relevant to the bacterial susceptibility testing surveillance. According to our results, amikacin as an injectable drug and nitrofurantoin as an oral agent could be used as a drug of choice in our region for children with UTIs.

  13. Convex Interval Games

    NARCIS (Netherlands)

    Alparslan-Gok, S.Z.; Brânzei, R.; Tijs, S.H.

    2008-01-01

    In this paper, convex interval games are introduced and some characterizations are given. Some economic situations leading to convex interval games are discussed. The Weber set and the Shapley value are defined for a suitable class of interval games and their relations with the interval core for

  14. Imaging tests in staging and surveillance of non-metastatic breast cancer: changes in routine clinical practice and cost implications.

    Science.gov (United States)

    De Placido, S; De Angelis, C; Giuliano, M; Pizzi, C; Ruocco, R; Perrone, V; Bruzzese, D; Tommasielli, G; De Laurentiis, M; Cammarota, S; Arpino, G; Arpino, G

    2017-03-14

    Although guidelines do not recommend computerised tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI) for the staging or follow-up of asymptomatic patients with non-metastatic breast cancer, they are often requested in routine clinical practice. The aim of this study was to determine the staging and follow-up patterns, and relative costs in a large population of breast cancer patients living and treated in a Southern Italian region. We analysed the clinical computerised information recorded by 567 primary-care physicians assisting about 650 000 inhabitants in the Campania region. Patients with non-metastatic breast cancer were identified and divided into calendar years from 2001 to 2010. The number of diagnostic tests prescribed per 100 patients (N/Pts) and the mean cost per patient was determined 3 months before diagnosis and up to 1 year after diagnosis. Costs are expressed in constant 2011 euros. We identified 4680 newly diagnosed cases of asymptomatic non-metastatic breast cancer. N/Pts increased significantly (Ptests'), and costs was unchanged. However, the number of CT, PET scans and MRI ('new tests')prescriptions almost quadrupled and the mean cost per patient related to these procedures significantly increased from [euro ]357 in 2001 to [euro ]830 in 2010 (Ptest prescriptions and relative costs significantly and steadily increased throughout the study period. At present there is no evidence that the delivery of new tests to asymptomatic patients improves breast cancer outcome. Well-designed clinical trials are urgently needed to shed light on the impact of these tests on clinical outcome and overall survival.

  15. Who is Surveilling Whom?

    DEFF Research Database (Denmark)

    Mortensen, Mette

    2014-01-01

    This article concerns the particular form of counter-surveillance termed “sousveillance”, which aims to turn surveillance at the institutions responsible for surveillance. Drawing on the theoretical perspectives “mediatization” and “aerial surveillance,” the article studies WikiLeaks’ publication...

  16. Surveillance of intestinal schistosomiasis during control: a comparison of four diagnostic tests across five Ugandan primary schools in the Lake Albert region.

    Science.gov (United States)

    Al-Shehri, Hajri; Koukounari, Artemis; Stanton, Michelle C; Adriko, Moses; Arinaitwe, Moses; Atuhaire, Aaron; Kabatereine, Narcis B; Stothard, J Russell

    2018-03-21

    Programmatic surveillance of intestinal schistosomiasis during control can typically use four diagnostic tests, either singularly or in combination, but these have yet to be cross-compared directly. Our study assembled a complete diagnostic dataset, inclusive of infection intensities, from 258 children from five Ugandan primary schools. The schools were purposely selected as typical of the endemic landscape near Lake Albert and reflective of high- and low-transmission settings. Overall prevalence was: 44.1% (95% CI 38.0-50.2) by microscopy of duplicate Kato-Katz smears from two consecutive stools, 56.9% (95% CI 50.8-63.0) by urine-circulating cathodic antigen (CCA) dipstick, 67.4% (95% CI 61.6-73.1) by DNA-TaqMan® and 75.1% (95% CI 69.8-80.4) by soluble egg antigen enzyme-linked immunosorbent assay (SEA-ELISA). A cross-comparison of diagnostic sensitivities, specificities, positive and negative predictive values was undertaken, inclusive of a latent class analysis (LCA) with a LCA-model estimate of prevalence by each school. The latter ranged from 9.6% to 100.0%, and prevalence by school for each diagnostic test followed a static ascending order or monotonic series of Kato-Katz, urine-CCA dipstick, DNA-TaqMan® and SEA-ELISA. We confirm that Kato-Katz remains a satisfactory diagnostic standalone in high-transmission settings but in low-transmission settings should be augmented or replaced by urine-CCA dipsticks. DNA-TaqMan® appears suitable in both endemic settings though is only implementable if resources permit. In low-transmission settings, SEA-ELISA remains the method of choice to evidence an absence infection. We discuss the pros and cons of each method concluding that future surveillance of intestinal schistosomiasis would benefit from a flexible, context-specific approach both in choice and application of each diagnostic method, rather than a single one-size fits all approach.

  17. Reuse fo a Cold War Surveillance Drone to Flight Test a NASA Rocket Based Combined Cycle Engine

    Science.gov (United States)

    Brown, T. M.; Smith, Norm

    1999-01-01

    Plans for and early feasibility investigations into the modification of a Lockheed D21B drone to flight test the DRACO Rocket Based Combined Cycle (RBCC) engine are discussed. Modifications include the addition of oxidizer tanks, modern avionics systems, actuators, and a vehicle recovery system. Current study results indicate that the D21B is a suitable candidate for this application and will allow demonstrations of all DRACO engine operating modes at Mach numbers between 0.8 and 4.0. Higher Mach numbers may be achieved with more extensive modification. Possible project risks include low speed stability and control, and recovery techniques.

  18. Visual interface for the automation of the instrumented pendulum of Charpy tests used in the surveillance program of reactors vessel of nuclear power plants

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Sainz M, E.; Ruiz E, J.A.

    2004-01-01

    Inside the Programs of Surveillance of the nuclear power stations periodic information is required on the state that keep the materials with those that builds the vessel of the reactor. This information is obtained through some samples or test tubes that are introduced inside the core of the reactor and it is observed if its physical characteristics remain after having been subjected to the radiation changes and temperature. The rehearsal with the instrumented Charpy pendulum offers information on the behavior of fracture dynamics of a material. In the National Institute of Nuclear Research (ININ) it has an instrumented Charpy pendulum. The operation of this instrument is manual, having inconveniences to carry out rehearsals with radioactive material, handling of high and low temperatures, to fulfill the normative ones for the realization of the rehearsals, etc. In this work the development of a computational program is presented (virtual instrument), for the automation of the instrumented pendulum. The system has modules like: Card of data acquisition, signal processing, positioning system, tempered system, pneumatic system, compute programs like it is the visual interface for the operation of the instrumented Charpy pendulum and the acquisition of impact signals. This system shows that given the characteristics of the nuclear industry with radioactive environments, the virtual instrumentation and the automation of processes can contribute to diminish the risks to the personnel occupationally exposed. (Author)

  19. Location-based HIV behavioural surveillance among MSM in Auckland, New Zealand 2002-2011: condom use stable and more HIV testing.

    Science.gov (United States)

    Saxton, Peter J W; Dickson, Nigel P; Hughes, Anthony J

    2014-03-01

    Over the last decade, annual HIV diagnoses among men who have sex with men (MSM) in New Zealand increased, then stabilised in 2006 and have not increased further. The aim was to examine trends in behaviours in order to better understand this pattern and inform community-based prevention. From 2002 to 2011, we conducted five repeat cross-sectional behavioural surveillance surveys among MSM at community locations in Auckland (fair day, gay bars, sex-on-site venues; n=6091). Participation was anonymous and self-completed. Recruitment methods were consistent at each round. Overall, the samples became more ethnically diverse and less gay community attached over time. Condom use during anal intercourse was stable across three partnering contexts (casual, current regular fuckbuddy, current regular boyfriend), with a drop among casual contacts in 2011 only. In the 6 months prior to surveys, there was a gradual decline over time in the proportion reporting >20 male partners, an increase in acquiring partners from the internet and increases in engagement in anal intercourse in some partnering contexts. HIV testing in the 12 months prior to surveys rose from 35.1% in 2002 to 50.4% in 2011, mostly from 2008. This first indepth examination of trends in HIV-related behaviours among five consecutive large and diverse samples of MSM in New Zealand does not suggest condom use is declining. However, subtle changes in sexual networks and partnering may be altering the epidemic determinants in this population and increasing exposure.

  20. Ideology, Critique and Surveillance

    Directory of Open Access Journals (Sweden)

    Heidi Herzogenrath-Amelung

    2013-11-01

    Full Text Available The 2013 revelations concerning global surveillance programmes demonstrate in unprecedented clarity the need for Critical Theory of information and communication technologies (ICTs to address the mechanisms and implications of increasingly global, ubiquitous surveillance. This is all the more urgent because of the dominance of the “surveillance ideology” (the promise of security through surveillance that supports the political economy of surveillance. This paper asks which theoretical arguments and concepts can be useful for philosophically grounding a critique of this surveillance ideology. It begins by examining how the surveillance ideology works through language and introduces the concept of the ‘ideological packaging’ of ICTs to show how rhetoric surrounding the implementation of surveillance technologies reinforces the surveillance ideology. It then raises the problem of how ideology-critique can work if it relies on language itself and argues that Martin Heidegger’s philosophy can make a useful contribution to existing critical approaches to language.

  1. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  2. Antimicrobial susceptibility of quinupristin/dalfopristin tested against gram-positive cocci from Latin America: results from the Global SMART (GSMART surveillance study

    Directory of Open Access Journals (Sweden)

    Sader Helio S.

    2001-01-01

    Full Text Available Gram-positive cocci are important causes of both nosocomial and community-acquired infections, and antimicrobial resistance among these pathogens has become an important problem worldwide. Since resistance among these organisms can vary substantially by geographic location, we conducted a multicenter surveillance study with isolates from five Latin American countries (15 medical centers. Quinupristin/dalfopristin (formerly RP-59500 is a novel streptogramin combination with focused activity against Gram-positive cocci, many exhibiting emerging resistance. The in vitro activity of quinupristin/dalfopristin and 12 other antimicrobial agents were evaluated against 1,948 strains including Staphylococcus aureus (747 strains, coagulase-negative staphylococci (CoNS; 446 strains, enterococci (429 strains, and various Streptococcus spp. (326 strains. Oxacillin resistance was observed in 41% of S. aureus (MIC, or = 13 mm and 40% of CoNS (MIC, or = 18 mm. Vancomycin, teicoplanin, and quinupristin/dalfopristin (MIC90, 0.25 - 1 mug/ml remained effective against all strains, but cross-resistance was high among other tested drugs. The quinupristin/dalfopristin MIC50 for Streptococcus pneumoniae and other streptococci was only 0.5 mug/ml (13% to 28% were penicillin-resistant; 12% to 22% were macrolide-resistant. Enterococci demonstrated variable inhibition by quinupristin/dalfopristin depending upon identification and the susceptibility testing method used. The demonstrated quinupristin/dalfopristin activity against Enterococcus faecium was confirmed, but potential species identification errors with various commercial systems continue to confuse susceptibility statistics, even though some strains of E. faecium confirmed by PCR-based or other molecular identification techniques did have quinupristin/dalfopristin MICs of > or = 4 mug/mL. Most important, glycopeptide-resistant enterococci are rapidly emerging in Latin America, and quinupristin/dalfopristin appears

  3. Cost effectiveness of surveillance for GI cancers.

    Science.gov (United States)

    Omidvari, Amir-Houshang; Meester, Reinier G S; Lansdorp-Vogelaar, Iris

    2016-12-01

    Gastrointestinal (GI) diseases are among the leading causes of death in the world. To reduce the burden of GI diseases, surveillance is recommended for some diseases, including for patients with inflammatory bowel diseases, Barrett's oesophagus, precancerous gastric lesions, colorectal adenoma, and pancreatic neoplasms. This review aims to provide an overview of the evidence on cost-effectiveness of surveillance of individuals with GI conditions predisposing them to cancer, specifically focussing on the aforementioned conditions. We searched the literature and reviewed 21 studies. Despite heterogeneity of studies in terms of settings, study populations, surveillance strategies and outcomes, most reviewed studies suggested at least some surveillance of patients with these GI conditions to be cost-effective. For some high-risk conditions frequent surveillance with 3-month intervals was warranted, while for other conditions, surveillance may only be cost-effective every 10 years. Further studies based on more robust effectiveness evidence are needed to inform and optimise surveillance programmes for GI cancers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  5. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  6. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning; Otimizacao aplicada ao planejamento de politicas de testes em sistemas nucleares por enxame de particulas

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Newton Norat

    2006-12-15

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  7. Interval Cancers in a Population-Based Screening Program for Colorectal Cancer in Catalonia, Spain

    Directory of Open Access Journals (Sweden)

    M. Garcia

    2015-01-01

    Full Text Available Objective. To analyze interval cancers among participants in a screening program for colorectal cancer (CRC during four screening rounds. Methods. The study population consisted of participants of a fecal occult blood test-based screening program from February 2000 to September 2010, with a 30-month follow-up (n = 30,480. We used hospital administration data to identify CRC. An interval cancer was defined as an invasive cancer diagnosed within 30 months of a negative screening result and before the next recommended examination. Gender, age, stage, and site distribution of interval cancers were compared with those in the screen-detected group. Results. Within the study period, 97 tumors were screen-detected and 74 tumors were diagnosed after a negative screening. In addition, 17 CRC (18.3% were found after an inconclusive result and 2 cases were diagnosed within the surveillance interval (2.1%. There was an increase of interval cancers over the four rounds (from 32.4% to 46.0%. When compared with screen-detected cancers, interval cancers were found predominantly in the rectum (OR: 3.66; 95% CI: 1.51–8.88 and at more advanced stages (P=0.025. Conclusion. There are large numbers of cancer that are not detected through fecal occult blood test-based screening. The low sensitivity should be emphasized to ensure that individuals with symptoms are not falsely reassured.

  8. Programming with Intervals

    Science.gov (United States)

    Matsakis, Nicholas D.; Gross, Thomas R.

    Intervals are a new, higher-level primitive for parallel programming with which programmers directly construct the program schedule. Programs using intervals can be statically analyzed to ensure that they do not deadlock or contain data races. In this paper, we demonstrate the flexibility of intervals by showing how to use them to emulate common parallel control-flow constructs like barriers and signals, as well as higher-level patterns such as bounded-buffer producer-consumer. We have implemented intervals as a publicly available library for Java and Scala.

  9. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  10. Robust misinterpretation of confidence intervals

    NARCIS (Netherlands)

    Hoekstra, Rink; Morey, Richard; Rouder, Jeffrey N.; Wagenmakers, Eric-Jan

    2014-01-01

    Null hypothesis significance testing (NHST) is undoubtedly the most common inferential technique used to justify claims in the social sciences. However, even staunch defenders of NHST agree that its outcomes are often misinterpreted. Confidence intervals (CIs) have frequently been proposed as a more

  11. The Development and Pilot Testing of the Marijuana Retail Surveillance Tool (MRST): Assessing Marketing and Point-of-Sale Practices among Recreational Marijuana Retailers

    Science.gov (United States)

    Berg, Carla J.; Henriksen, Lisa; Cavazos-Rehg, Patricia; Schauer, Gillian L.; Freisthler, Bridget

    2017-01-01

    As recreational marijuana expands, it is critical to develop standardized surveillance measures to study the retail environment. To this end, our research team developed and piloted a tool assessing recreational marijuana retailers in a convenience sample of 20 Denver retailers in 2016. The tool assesses: (i) compliance and security (e.g.…

  12. A critical look at prospective surveillance using a scan statistic.

    Science.gov (United States)

    Correa, Thais R; Assunção, Renato M; Costa, Marcelo A

    2015-03-30

    The scan statistic is a very popular surveillance technique for purely spatial, purely temporal, and spatial-temporal disease data. It was extended to the prospective surveillance case, and it has been applied quite extensively in this situation. When the usual signal rules, as those implemented in SaTScan(TM) (Boston, MA, USA) software, are used, we show that the scan statistic method is not appropriate for the prospective case. The reason is that it does not adjust properly for the sequential and repeated tests carried out during the surveillance. We demonstrate that the nominal significance level α is not meaningful and there is no relationship between α and the recurrence interval or the average run length (ARL). In some cases, the ARL may be equal to ∞, which makes the method ineffective. This lack of control of the type-I error probability and of the ARL leads us to strongly oppose the use of the scan statistic with the usual signal rules in the prospective context. Copyright © 2014 John Wiley & Sons, Ltd.

  13. A Radiation-Triggered Surveillance System for UF6 Cylinder Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Michael M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myjak, Mitchell J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-23

    This report provides background information and representative scenarios for testing a prototype radiation-triggered surveillance system at an operating facility that handles uranium hexafluoride (UF6) cylinders. The safeguards objective is to trigger cameras using radiation, or radiation and motion, rather than motion alone, to reduce significantly the number of image files generated by a motion-triggered system. The authors recommend the use of radiation-triggered surveillance at all facilities where cylinder paths are heavily traversed by personnel. The International Atomic Energy Agency (IAEA) has begun using surveillance cameras in the feed and withdrawal areas of gas centrifuge enrichment plants (GCEPs). The cameras generate imagery using elapsed time or motion, but this creates problems in areas occupied 24/7 by personnel. Either motion-or-interval-based triggering generates thousands of review files over the course of a month. Since inspectors must review the files to verify operator material-flow-declarations, a plethora of files significantly extends the review process. The primary advantage of radiation-triggered surveillance is the opportunity to obtain full-time cylinder throughput verification versus what presently amounts to part-time verification. Cost savings should be substantial, as the IAEA presently uses frequent unannounced inspections to verify cylinder-throughput declarations. The use of radiation-triggered surveillance allows the IAEA to implement less frequent unannounced inspections for the purpose of flow verification, but its principal advantage is significantly shorter and more effective inspector video reviews.

  14. 用Delta法估计多维测验合成信度的置信区间%Estimating the Confidence Interval of Composite Reliability of a Multidimensional Test With the Delta Method

    Institute of Scientific and Technical Information of China (English)

    叶宝娟; 温忠麟

    2012-01-01

    Reliability is very important in evaluating the quality of a test. Based on the confirmatory factor analysis, composite reliabili- ty is a good index to estimate the test reliability for general applications. As is well known, point estimate contains limited information a- bout a population parameter and cannot indicate how far it can be from the population parameter. The confidence interval of the parame- ter can provide more information. In evaluating the quality of a test, the confidence interval of composite reliability has received atten- tion in recent years. There are three approaches to estimating the confidence interval of composite reliability of an unidimensional test: the Bootstrap method, the Delta method, and the direct use of the standard error of a software output (e. g. , LISREL). The Bootstrap method pro- vides empirical results of the standard error, and is the most credible method. But it needs data simulation techniques, and its computa- tion process is rather complex. The Delta method computes the standard error of composite reliability by approximate calculation. It is simpler than the Bootstrap method. The LISREL software can directly prompt the standard error, and it is the easiest among the three methods. By simulation study, it had been found that the interval estimates obtained by the Delta method and the Bootstrap method were almost identical, whereas the results obtained by LISREL and by the Bootstrap method were substantially different ( Ye & Wen, 2011 ). The Delta method is recommended when the confidence interval of composite reliability of a unidimensional test is estimated, because the Delta method is simpler than the Bootstrap method. There was little research about how to compute the confidence interval of composite reliability of a multidimensional test. We de- duced a formula by using the Delta method for computing the standard error of composite reliability of a multidimensional test. Based on the standard error, the

  15. Adherence to colorectal polyp surveillance guidelines: is there a 'scope' to increase the opportunities for screening?

    LENUS (Irish Health Repository)

    O'Connor, Anthony

    2012-02-01

    Colorectal polyps are usually asymptomatic and are found opportunistically. Individuals with adenomata are at increased risk for cancer and therefore guidelines exist for surveillance of these lesions including those of the British Society of Gastroenterology (BSG). Deviation from these guidelines is common and increases the workload of endoscopy. We examined those individuals waiting for endoscopy for polyp surveillance to see whether strict adherence to BSG guidelines could facilitate opportunities for screening. A total of 413 patients with earlier colonic polyps were examined, of whom 50 patients were excluded based on having alternative indications for surveillance, 179 (49.3%) were appropriately scheduled for surveillance and 184 patients (55.9%) were scheduled incorrectly. Seventy-nine patients (30%) could have been discharged; of these, 59 had hyperplastic polyps. Of the remaining 105 inappropriate triages under surveillance at the wrong interval, seven patients were scheduled for too infrequent surveillance and 98 were too frequent. A total of 284 patients with adenomatous polyps were under surveillance of whom 11 patients (3.8%) were in the high-risk category and all were appropriately scheduled, and 75 patients (26.4%) were in the intermediate-risk category, of whom 48 were appropriately scheduled, 20 were incorrectly triaged as high risk and seven were triaged as low risk. A total of 198 (69.7%) patients were in the low-risk category, 117 of these were correctly triaged, 15 were incorrectly triaged as high risk and 66 were classified as intermediate risk. Over a five-year period, 318 unnecessary colonoscopies are being performed. On the basis of the data obtained from a population-based colorectal screening programme using immunohistochemical-faecal occult blood testing in our department another 1516 patients could be screened annually without requiring any additional endoscopy resources, if strict adherence to guidelines was assured.

  16. Development of a web-based epidemiological surveillance system with health system response for improving maternal and newborn health: Field-testing in Thailand.

    Science.gov (United States)

    Liabsuetrakul, Tippawan; Prappre, Tagoon; Pairot, Pakamas; Oumudee, Nurlisa; Islam, Monir

    2017-06-01

    Surveillance systems are yet to be integrated with health information systems for improving the health of pregnant mothers and their newborns, particularly in developing countries. This study aimed to develop a web-based epidemiological surveillance system for maternal and newborn health with integration of action-oriented responses and automatic data analysis with results presentations and to assess the system acceptance by nurses and doctors involved in various hospitals in southern Thailand. Freeware software and scripting languages were used. The system can be run on different platforms, and it is accessible via various electronic devices. Automatic data analysis with results presentations in the forms of graphs, tables and maps was part of the system. A multi-level security system was incorporated into the program. Most doctors and nurses involved in the study felt the system was easy to use and useful. This system can be integrated into country routine reporting system for monitoring maternal and newborn health and survival.

  17. The effects of interstimulus interval on event-related indices of attention: an auditory selective attention test of perceptual load theory.

    Science.gov (United States)

    Gomes, Hilary; Barrett, Sophia; Duff, Martin; Barnhardt, Jack; Ritter, Walter

    2008-03-01

    We examined the impact of perceptual load by manipulating interstimulus interval (ISI) in two auditory selective attention studies that varied in the difficulty of the target discrimination. In the paradigm, channels were separated by frequency and target/deviant tones were softer in intensity. Three ISI conditions were presented: fast (300ms), medium (600ms) and slow (900ms). Behavioral (accuracy and RT) and electrophysiological measures (Nd, P3b) were observed. In both studies, participants evidenced poorer accuracy during the fast ISI condition than the slow suggesting that ISI impacted task difficulty. However, none of the three measures of processing examined, Nd amplitude, P3b amplitude elicited by unattended deviant stimuli, or false alarms to unattended deviants, were impacted by ISI in the manner predicted by perceptual load theory. The prediction based on perceptual load theory, that there would be more processing of irrelevant stimuli under conditions of low as compared to high perceptual load, was not supported in these auditory studies. Task difficulty/perceptual load impacts the processing of irrelevant stimuli in the auditory modality differently than predicted by perceptual load theory, and perhaps differently than in the visual modality.

  18. Determinants and consequences of short birth interval in rural Bangladesh: A cross-sectional study

    NARCIS (Netherlands)

    H.R. de Jonge (Hugo); K. Azad (Kishwar); N. Seward (Nadine); A. Kuddus (Abdul); S. Shaha (Sanjit); J. Beard (James); A. Costello (Anthony); A.J. Houweling (Tanja); E. Fottrell (Edward)

    2014-01-01

    textabstractBackground: Short birth intervals are known to have negative effects on pregnancy outcomes. We analysed data from a large population surveillance system in rural Bangladesh to identify predictors of short birth interval and determine consequences of short intervals on pregnancy outcomes.

  19. Digitally Available Interval-Specific Rock-Sample Data Compiled from Historical Records, Nevada Test Site and Vicinity, Nye County, Nevada.

    Energy Technology Data Exchange (ETDEWEB)

    David B. Wood

    2007-10-24

    Between 1951 and 1992, 828 underground tests were conducted on the Nevada Test Site, Nye County, Nevada. Prior to and following these nuclear tests, holes were drilled and mined to collect rock samples. These samples are organized and stored by depth of borehole or drift at the U.S. Geological Survey Core Library and Data Center at Mercury, Nevada, on the Nevada Test Site. From these rock samples, rock properties were analyzed and interpreted and compiled into project files and in published reports that are maintained at the Core Library and at the U.S. Geological Survey office in Henderson, Nevada. These rock-sample data include lithologic descriptions, physical and mechanical properties, and fracture characteristics. Hydraulic properties also were compiled from holes completed in the water table. Rock samples are irreplaceable because pre-test, in-place conditions cannot be recreated and samples cannot be recollected from the many holes destroyed by testing. Documenting these data in a published report will ensure availability for future investigators.

  20. Digitally Available Interval-Specific Rock-Sample Data Compiled from Historical Records, Nevada Test Site and Vicinity, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    David B. Wood

    2009-10-08

    Between 1951 and 1992, underground nuclear weapons testing was conducted at 828 sites on the Nevada Test Site, Nye County, Nevada. Prior to and following these nuclear tests, holes were drilled and mined to collect rock samples. These samples are organized and stored by depth of borehole or drift at the U.S. Geological Survey Core Library and Data Center at Mercury, Nevada, on the Nevada Test Site. From these rock samples, rock properties were analyzed and interpreted and compiled into project files and in published reports that are maintained at the Core Library and at the U.S. Geological Survey office in Henderson, Nevada. These rock-sample data include lithologic descriptions, physical and mechanical properties, and fracture characteristics. Hydraulic properties also were compiled from holes completed in the water table. Rock samples are irreplaceable because pre-test, in-place conditions cannot be recreated and samples cannot be recollected from the many holes destroyed by testing. Documenting these data in a published report will ensure availability for future investigators.

  1. Redefining syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Rebecca Katz

    2011-12-01

    Full Text Available With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field’s capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries.

  2. Airborne Video Surveillance

    National Research Council Canada - National Science Library

    Blask, Steven

    2002-01-01

    The DARPA Airborne Video Surveillance (AVS) program was established to develop and promote technologies to make airborne video more useful, providing capabilities that achieve a UAV force multiplier...

  3. Handbook of surveillance technologies

    CERN Document Server

    Petersen, JK

    2012-01-01

    From officially sanctioned, high-tech operations to budget spy cameras and cell phone video, this updated and expanded edition of a bestselling handbook reflects the rapid and significant growth of the surveillance industry. The Handbook of Surveillance Technologies, Third Edition is the only comprehensive work to chronicle the background and current applications of the full-range of surveillance technologies--offering the latest in surveillance and privacy issues.Cutting-Edge--updates its bestselling predecessor with discussions on social media, GPS circuits in cell phones and PDAs, new GIS s

  4. The surveillance error grid.

    Science.gov (United States)

    Klonoff, David C; Lias, Courtney; Vigersky, Robert; Clarke, William; Parkes, Joan Lee; Sacks, David B; Kirkman, M Sue; Kovatchev, Boris

    2014-07-01

    Currently used error grids for assessing clinical accuracy of blood glucose monitors are based on out-of-date medical practices. Error grids have not been widely embraced by regulatory agencies for clearance of monitors, but this type of tool could be useful for surveillance of the performance of cleared products. Diabetes Technology Society together with representatives from the Food and Drug Administration, the American Diabetes Association, the Endocrine Society, and the Association for the Advancement of Medical Instrumentation, and representatives of academia, industry, and government, have developed a new error grid, called the surveillance error grid (SEG) as a tool to assess the degree of clinical risk from inaccurate blood glucose (BG) monitors. A total of 206 diabetes clinicians were surveyed about the clinical risk of errors of measured BG levels by a monitor. The impact of such errors on 4 patient scenarios was surveyed. Each monitor/reference data pair was scored and color-coded on a graph per its average risk rating. Using modeled data representative of the accuracy of contemporary meters, the relationships between clinical risk and monitor error were calculated for the Clarke error grid (CEG), Parkes error grid (PEG), and SEG. SEG action boundaries were consistent across scenarios, regardless of whether the patient was type 1 or type 2 or using insulin or not. No significant differences were noted between responses of adult/pediatric or 4 types of clinicians. Although small specific differences in risk boundaries between US and non-US clinicians were noted, the panel felt they did not justify separate grids for these 2 types of clinicians. The data points of the SEG were classified in 15 zones according to their assigned level of risk, which allowed for comparisons with the classic CEG and PEG. Modeled glucose monitor data with realistic self-monitoring of blood glucose errors derived from meter testing experiments plotted on the SEG when compared to

  5. [Entomological surveillance in Mauritius].

    Science.gov (United States)

    Gopaul, R

    1995-01-01

    The entomological surveillance is an essential link in the fight against malaria in Mauritius. Because of the large number of malaria-infected travellers in Mauritius and the presence of the vector Anopheles arabiensis, the risk of local transmission is very real. The medical entomology division together with the malaria control unit and the health appointees exert a rigorous entomological surveillance of malaria. Field agents make entomological investigations of pilot villages and around the harbor and airport, where there have been cases of malaria, in addition to a few randomly chosen regions. All of the inhabited regions are accessible because of a good highway infrastructure, which enables a complete coverage for the entomological prospectives. Entomological controls are also conducted in the airplanes and the ships. All of the captured mosquitos and the harvested larva are transferred to a laboratory for identification, dissection or sensibility tests, etc. The larva of A. arabiensis have not yet developed resistance to Temephos and the adults are still sensitive to DDT. Thus, the larval habitats are treated with Temephos and DDT is sprayed in the residences where there have been native cases of malaria. The entomology division studies the ecology and the evolution of the larval habitats, as well as the impact of the anti-larval fight on the anophelene density. In addition to the chemical fight, a biological control is being tried with larva-eating fish such as Lebistes and Tilapia. In general, the anophelene density in Mauritius is low, but after the big summer rains, especially during a period of cyclones, there is a considerable increase of larval habitats and consequently a higher number of A. arabiensis. Therefore during this season, it is necessary to make an even more rigorous entomological surveillance. A. arabiensis has a strong exophile tendency even if it is endophage and exophage. This mosquito is zoophile, mostly towards cattle, and the

  6. Practical Considerations about Expected A Posteriori Estimation in Adaptive Testing: Adaptive A Priori, Adaptive Correction for Bias, and Adaptive Integration Interval.

    Science.gov (United States)

    Raiche, Gilles; Blais, Jean-Guy

    In a computerized adaptive test (CAT), it would be desirable to obtain an acceptable precision of the proficiency level estimate using an optimal number of items. Decreasing the number of items is accompanied, however, by a certain degree of bias when the true proficiency level differs significantly from the a priori estimate. G. Raiche (2000) has…

  7. Surveillance for West Nile virus in clinic-admitted raptors, Colorado.

    Science.gov (United States)

    Nemeth, Nicole; Kratz, Gail; Edwards, Eric; Scherpelz, Judy; Bowen, Richard; Komar, Nicholas

    2007-02-01

    In 2005, 13.5% of clinic-admitted raptors in northern Colorado tested positive for West Nile virus (WNV). Clinic-admitted-raptor surveillance detected WNV activity nearly 14 weeks earlier than other surveillance systems. WNV surveillance using live raptor admissions to rehabilitation clinics may offer a novel surveillance method and should be considered along with other techniques already in use.

  8. Improvements to Technical Specifications surveillance requirements

    International Nuclear Information System (INIS)

    Lobel, R.; Tjader, T.R.

    1992-12-01

    In August 1983 an NRC task group was formed to investigate problems with surveillance testing required by Technical Specifications, and to recommend approaches to effect improvements. NUREG-1024 (''Technical Specifications-Enhancing Safety Impact'') resulted, and it contained recommendations to review the basis for test frequencies; to ensure that the tests promote safety and do not degrade equipment; and to review surveillance tests so that they do not unnecessarily burden personnel. The Technical Specifications Improvement Program (TSIP) was established in December 1984 to provide the framework for rewriting and improving the Technical Specifications. As an element of the TSIP, all Technical Specifications surveillance requirements were comprehensively examined as recommended in NUREG-1024. The results of that effort are presented in this report. The study found that while some testing at power is essential to verify equipment and system operability, safety can be improved, equipment degradation decreased, and unnecessary personnel burden relaxed by reducing the amount of testing at power

  9. Haemostatic reference intervals in pregnancy

    DEFF Research Database (Denmark)

    Szecsi, Pal Bela; Jørgensen, Maja; Klajnbard, Anna

    2010-01-01

    Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age-specific refe......Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age......-specific reference intervals for coagulation tests during normal pregnancy. Eight hundred one women with expected normal pregnancies were included in the study. Of these women, 391 had no complications during pregnancy, vaginal delivery, or postpartum period. Plasma samples were obtained at gestational weeks 13......-20, 21-28, 29-34, 35-42, at active labor, and on postpartum days 1 and 2. Reference intervals for each gestational period using only the uncomplicated pregnancies were calculated in all 391 women for activated partial thromboplastin time (aPTT), fibrinogen, fibrin D-dimer, antithrombin, free protein S...

  10. Soil and vegetation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    Soil sampling and analysis evaluates long-term contamination trends and monitors environmental radionuclide inventories. This section of the 1994 Hanford Site Environmental Report summarizes the soil and vegetation surveillance programs which were conducted during 1994. Vegetation surveillance is conducted offsite to monitor atmospheric deposition of radioactive materials in areas not under cultivation and onsite at locations adjacent to potential sources of radioactivity.

  11. Between visibility and surveillance

    DEFF Research Database (Denmark)

    Uldam, Julie

    As activists move from alternative media platforms to commercial social media platforms they face increasing challenges in protecting their online security and privacy. While government surveillance of activists is well-documented in both scholarly research and the media, corporate surveillance...

  12. Reassembling Surveillance Creep

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Lauritsen, Peter

    2017-01-01

    We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical developm......We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical...... development or in empirical analyses. Accordingly, this article contributes to this special issue on the usefulness of Actor-Network Theory (ANT) by suggesting that ANT can advance our understanding of ‘surveillance creep’. Based on ANT’s model of translation and a historical study of the Danish DNA database......, we argue that surveillance creep involves reassembling the relations in surveillance networks between heterogeneous actors such as the watchers, the watched, laws, and technologies. Second, surveillance creeps only when these heterogeneous actors are adequately interested and aligned. However...

  13. OFF! Clip-on Repellent Device With Metofluthrin Tested on Aedes aegypti (Diptera: Culicidae) for Mortality at Different Time Intervals and Distances.

    Science.gov (United States)

    Bibbs, Christopher S; Xue, Rui-De

    2016-03-01

    The OFF! Clip-on mosquito-repellent device was tested outdoors against Aedes aegypti (L.). A single treatment device was used against batches of caged adult, nonblood fed Ae. aegypti at multiple locations 0.3m from treatment center. Another set of cages was stationed 0.6m from treatment. A final set of cages was placed 0.9m away. Trials ran for durations of 5, 15, 30, and 60 min. Initial knockdown and mortality after 24 h was recorded. The devices had effective knockdown and mortality. This was not sustained at distances greater than 0.3m from the device.

  14. Development of Compact Surveillance and Monitoring System `COSMOS`

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Hironobu; Mukaiyama, Takehiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  15. Development of Compact Surveillance and Monitoring System 'COSMOS'

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  16. Overconfidence in Interval Estimates

    Science.gov (United States)

    Soll, Jack B.; Klayman, Joshua

    2004-01-01

    Judges were asked to make numerical estimates (e.g., "In what year was the first flight of a hot air balloon?"). Judges provided high and low estimates such that they were X% sure that the correct answer lay between them. They exhibited substantial overconfidence: The correct answer fell inside their intervals much less than X% of the time. This…

  17. The Post-Ovariectomy Interval Affects the Antidepressant-Like Action of Citalopram Combined with Ethynyl-Estradiol in the Forced Swim Test in Middle Aged Rats

    Directory of Open Access Journals (Sweden)

    Nelly M. Vega Rivera

    2016-05-01

    Full Text Available The use of a combined therapy with low doses of estrogens plus antidepressants to treat depression associated to perimenopause could be advantageous. However the use of these combinations is controversial due to several factors, including the time of intervention in relation to menopause onset. This paper analyzes whether time post-OVX influences the antidepressant-like action of a combination of ethynyl-estradiol (EE2 and citalopram (CIT in the forced swim test (FST. Middle-aged (15 months old female Wistar rats were ovariectomized and after one or three weeks treated with EE2 (1.25, 2.5 or 5.0 µg/rat, s.c.; −48 h or CIT (1.25, 2.5, 5.0 or 10 mg/kg, i.p./3 injections in 24 h and tested in the FST. In a second experiment, after one or three weeks of OVX, rats received a combination of an ineffective dose of EE2 (1.25 µg/rat, s.c., −48 h plus CIT (2.5 mg/kg, i.p./3 injections in 24 h and subjected to the FST. Finally, the uteri were removed and weighted to obtain an index of the peripheral effects of EE2 administration. EE2 (2.5 or 5.0 µg/rat reduced immobility after one but not three weeks of OVX. In contrast, no CIT dose reduced immobility at one or three weeks after OVX. When EE2 (1.25 µg/rat was combined with CIT (2.5 mg/kg an antidepressant-like effect was observed at one but not three weeks post-OVX. The weight of the uteri augmented when EE2 was administrated three weeks after OVX. The data suggest that the time post-OVX is a crucial factor that contributes to observe the antidepressant-like effect of EE2 alone or in combination with CIT.

  18. Using Google Trends for influenza surveillance in South China.

    Science.gov (United States)

    Kang, Min; Zhong, Haojie; He, Jianfeng; Rutherford, Shannon; Yang, Fen

    2013-01-01

    Google Flu Trends was developed to estimate influenza activity in many countries; however there is currently no Google Flu Trends or other Internet search data used for influenza surveillance in China. Influenza surveillance data from 2008 through 2011 were obtained from provincial CDC influenza-like illness and virological surveillance systems of Guangdong, a province in south China. Internet search data were downloaded from the website of Google Trends. Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data and internet search trends. The correlation between CDC ILI surveillance and CDC virus surveillance was 0.56 (95% CI: 0.43, 0.66). The strongest correlation was between the Google Trends term of Fever and ILI surveillance with a correlation coefficient of 0.73 (95% CI: 0.66, 0.79). When compared with influenza virological surveillance, the Google Trends term of Influenza A had the strongest correlation with a correlation coefficient of 0.64 (95% CI: 0.43, 0.79) in the 2009 H1N1 influenza pandemic period. This study shows that Google Trends in Chinese can be used as a complementary source of data for influenza surveillance in south China. More research in the future should develop new models using search trends in Chinese language to estimate local disease activity and detect early signals of outbreaks.

  19. A Survey of Colonoscopic Surveillance After Polypectomy

    Science.gov (United States)

    2014-01-01

    Purpose Several guidelines have been proposed for surveillance colonoscopy after polypectomy. However, some discrepancies still exist between the guidelines and clinical practice. This study was conducted to identify Korean doctors' recommendations for the colonoscopic surveillance interval after polypectomy. Methods A survey of the attendees at the symposium of the 64th Annual Congress of the Korean Surgical Society was conducted. When the prepared clinical scenarios were given, attendees answered using a wireless radio-frequency audience response system. All responders' results were automatically counted immediately. Frequencies of different answers to each question were calculated, and our results were compared with those of previous surveys performed using the same questionnaire in the United States or Japan. Results The number of responder varied from 38 to 41. About 50% of valid responders selected 'follow-up in 3 years' for low-risk lesions, such as a 6-mm hyperplastic polyp, a 6-mm tubular adenoma, or two 6-mm tubular adenomas. Responders most-commonly selected 'follow-up in 1 year' for high-risk lesions, such as a 12-mm tubular adenoma with high grade dysplasia or a 12-mm tubulovillous adenoma. The majority of Korean doctors recommend postpolypectomy colonoscopic surveillance more frequently than American physicians did. Conclusion A discrepancy between the guidelines and clinical practice for the surveillance after polypectomy still exists in Korea. A surveillance program that can be easily and widely applied in clinical practice needs to be established. PMID:24851219

  20. Development of a methodology for optimization of technical specifications using PSA based techniques. Development of methodology for evaluation of STI (Surveillance Test Interval) and AOT (Allowed Outage Time) in technical specifications using PSA techniques

    International Nuclear Information System (INIS)

    Jong In Lee; Dae Wook Chung; Sok Chul Kim

    1997-01-01

    In Korea, continued improvement of the safety of nuclear power plants has been set as national policy for the construction and operation of NPPs. Safety Related regulatory requirements under the Korea's Atomic Energy Laws are strictly observed in the design, fabrication, construction, and operation of NPPs. Safety regulation as regulatory concepts, efficient management of regulatory organizations, and rationalization will be improved further through the improvement of regulatory systems, introduction of to technical standards. The following improvements are considered: Periodical safety reevaluation of the operating plants; licensing system allowing certification for standard design and comprehensive site approval; and severe accident policies and criteria established for next generation reactors

  1. Applications of interval computations

    CERN Document Server

    Kreinovich, Vladik

    1996-01-01

    Primary Audience for the Book • Specialists in numerical computations who are interested in algorithms with automatic result verification. • Engineers, scientists, and practitioners who desire results with automatic verification and who would therefore benefit from the experience of suc­ cessful applications. • Students in applied mathematics and computer science who want to learn these methods. Goal Of the Book This book contains surveys of applications of interval computations, i. e. , appli­ cations of numerical methods with automatic result verification, that were pre­ sented at an international workshop on the subject in EI Paso, Texas, February 23-25, 1995. The purpose of this book is to disseminate detailed and surveyed information about existing and potential applications of this new growing field. Brief Description of the Papers At the most fundamental level, interval arithmetic operations work with sets: The result of a single arithmetic operation is the set of all possible results as the o...

  2. Radiation detectors as surveillance monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Dowdy, E.J.

    1981-01-01

    The International Atomic Energy Agency (IAEA) proposes to use personnel dosimetry radiation detectors as surveillance monitors for safeguards purposes. It plans to place these YES/NO monitors at barrier penetration points declared closed under IAEA safeguards to detect the passage of plutonium-bearing nuclear material, usually spent fuel. For this application, commercially available dosimeters were surveyed as well as other radiation detectors that appeared suitable and likely to be marketed in the near future. No primary advantage was found in a particular detector type because in this application backgrounds vary during long counting intervals. Secondary considerations specify that the monitor be inexpensive and easy to tamper-proof, interrogate, and maintain. On this basis radiophotoluminescent, thermoluminescent, and electronic dosimeters were selected as possible routine monitors; the latter two may prove useful for data-base acquisition

  3. The development and pilot testing of the marijuana retail surveillance tool (MRST): assessing marketing and point-of-sale practices among recreational marijuana retailers.

    Science.gov (United States)

    Berg, Carla J; Henriksen, Lisa; Cavazos-Rehg, Patricia; Schauer, Gillian L; Freisthler, Bridget

    2017-12-01

    As recreational marijuana expands, it is critical to develop standardized surveillance measures to study the retail environment. To this end, our research team developed and piloted a tool assessing recreational marijuana retailers in a convenience sample of 20 Denver retailers in 2016. The tool assesses: (i) compliance and security (e.g. age-of-sale signage, ID checks, security cameras); (ii) marketing (i.e. promotions, product availability and price) and (iii) contextual and neighborhood features (i.e. retailer type, facilities nearby). Most shops (90.0%) indicated the minimum age requirement, all verified age. All shops posted interior ads (M = 2.6/retailer, SD = 3.4), primarily to promote edibles and other non-smoked products. Price promotions were common in shops (73.7%), 57.9% used social media promotions and 31.6% had take-away materials (e.g. menus, party promotions). Nearly half of the shops (42.1%) advertised health claims. All shops offered bud, joints, honey oil, tinctures, kief, beverages, edibles and topicals; fewer sold clones and seeds. Six shops (31.6%) sold shop-branded apparel and/or paraphernalia. Prices for bud varied within and between stores ($20-$45/'eighth', ∼3.5 g). Twelve were recreational only, and eight were both recreational and medicinal. Liquor stores were commonly proximal. Reliability assessments with larger, representative samples are needed to create a standardized marijuana retail surveillance tool. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Early detection surveillance for an emerging plant pathogen: a rule of thumb to predict prevalence at first discovery.

    Science.gov (United States)

    Parnell, S; Gottwald, T R; Cunniffe, N J; Alonso Chavez, V; van den Bosch, F

    2015-09-07

    Emerging plant pathogens are a significant problem for conservation and food security. Surveillance is often instigated in an attempt to detect an invading epidemic before it gets out of control. Yet in practice many epidemics are not discovered until already at a high prevalence, partly due to a lack of quantitative understanding of how surveillance effort and the dynamics of an invading epidemic relate. We test a simple rule of thumb to determine, for a surveillance programme taking a fixed number of samples at regular intervals, the distribution of the prevalence an epidemic will have reached on first discovery (discovery-prevalence) and its expectation E(q*). We show that E(q*) = r/(N/Δ), i.e. simply the rate of epidemic growth divided by the rate of sampling; where r is the epidemic growth rate, N is the sample size and Δ is the time between sampling rounds. We demonstrate the robustness of this rule of thumb using spatio-temporal epidemic models as well as data from real epidemics. Our work supports the view that, for the purposes of early detection surveillance, simple models can provide useful insights in apparently complex systems. The insight can inform decisions on surveillance resource allocation in plant health and has potential applicability to invasive species generally. © 2015 The Author(s).

  5. The Copyright Surveillance Industry

    Directory of Open Access Journals (Sweden)

    Mike Zajko

    2015-09-01

    Full Text Available Creative works are now increasingly distributed as digital “content” through the internet, and copyright law has created powerful incentives to monitor and control these flows. This paper analyzes the surveillance industry that has emerged as a result. Copyright surveillance systems identify copyright infringement online and identify persons to hold responsible for infringing acts. These practices have raised fundamental questions about the nature of identification and attribution on the internet, as well as the increasing use of algorithms to make legal distinctions. New technologies have threatened the profits of some media industries through copyright infringement, but also enabled profitable forms of mass copyright surveillance and enforcement. Rather than a system of perfect control, copyright enforcement continues to be selective and uneven, but its broad reach results in systemic harm and provides opportunities for exploitation. It is only by scrutinizing copyright surveillance practices and copyright enforcement measures that we can evaluate these consequences.

  6. Deployment Health Surveillance

    National Research Council Canada - National Science Library

    DeNicola, Anthony D

    2004-01-01

    ... of stress in causing chronic illness. The lack of comprehensive deployment health surveillance has made it difficult to determine possible causes of adverse health effects reported by Gulf War veterans...

  7. 522 Postmarket Surveillance Studies

    Data.gov (United States)

    U.S. Department of Health & Human Services — The 522 Postmarket Surveillance Studies Program encompasses design, tracking, oversight, and review responsibilities for studies mandated under section 522 of the...

  8. Sanitary surveillance and bioethics

    Directory of Open Access Journals (Sweden)

    Volnei Garrafa

    2017-08-01

    Full Text Available Regulatory practices in the field of health surveillance are indispensable. The aim of this study is to show ‒ taking the Brazilian National Surveillance Agency, governing body of sanitary surveillance in Brazil as a reference ‒ that bioethics provides public bodies a series of theoretical tools from the field of applied ethics for the proper exercise and control of these practices. To that end, the work uses two references of bioethics for the development of a comparative and supportive analysis to regulatory activities in the field of health surveillance: the Universal Declaration on Bioethics and Human Rights of Unesco and the theory of intervention bioethics. We conclude that organizations and staff working with regulatory activities can take advantage of the principles and frameworks proposed by bioethics, especially those related to the Declaration and the theory of intervention bioethics, the latter being set by the observation and use of the principles of prudence, precaution, protection and prevention.

  9. Brucella abortus surveillance of cattle in Fiji, Papua New Guinea, Vanuatu, the Solomon Islands and a case for active disease surveillance as a training tool.

    Science.gov (United States)

    Tukana, Andrew; Hedlefs, Robert; Gummow, Bruce

    2016-10-01

    There have been no surveys of the cattle population for brucellosis in the Pacific Island Countries and Territories (PICTs) for more than 15 years. This study used disease surveillance as a capacity building training tool and to examine some of the constraints that impede surveillance in PICTs. The study also developed and implemented a series of surveys for detecting antibodies to B. abortus in cattle in Fiji, Papua New Guinea, Vanuatu and the Solomon Islands contributing to OIE requirements. The findings indicated lack of funds, lack of technical capacity, shortage of veterinarians, high turnover of in-country officials and lack of awareness on the impacts of animal diseases on public health that were constraining active disease surveillance. During the development and implementation of the surveys, constraints highlighted were outdated census data on farm numbers and cattle population, lack of funds for mobilisation of officials to carry out the surveys, lack of equipment for collecting and processing samples, lack of staff knowledge on blood sampling, geographical difficulties and security in accessing farms. Some of the reasons why these were constraints are discussed with likely solutions presented. The detection surveys had the objectives of building capacity for the country officials and demonstrating freedom from brucellosis in cattle for PNG, Vanuatu and the Solomon Islands. PNG, Vanuatu and the Solomon Islands all demonstrated freedom from bovine brucellosis in the areas surveyed using the indirect ELISA test. Fiji had an outbreak of brucellosis, and the objective was to determine its distribution and prevalence on untested farms. The Muaniweni district surveyed during the training had a 95 % confidence interval for true prevalence between 1.66 and 5.45 %. The study showed that active disease surveillance could be used as a tool for training officials thus, improves surveillance capacity in resource poor countries.

  10. Limited utility of routine surveillance imaging for classical Hodgkin lymphoma patients in first complete remission.

    Science.gov (United States)

    Pingali, Sai Ravi; Jewell, Sarah W; Havlat, Luiza; Bast, Martin A; Thompson, Jonathan R; Eastwood, Daniel C; Bartlett, Nancy L; Armitage, James O; Wagner-Johnston, Nina D; Vose, Julie M; Fenske, Timothy S

    2014-07-15

    The objective of this study was to compare the outcomes of patients with classical Hodgkin lymphoma (cHL) who achieved complete remission with frontline therapy and then underwent either clinical surveillance or routine surveillance imaging. In total, 241 patients who were newly diagnosed with cHL between January 2000 and December 2010 at 3 participating tertiary care centers and achieved complete remission after first-line therapy were retrospectively analyzed. Of these, there were 174 patients in the routine surveillance imaging group and 67 patients in the clinical surveillance group, based on the intended mode of surveillance. In the routine surveillance imaging group, the intended plan of surveillance included computed tomography and/or positron emission tomography scans; whereas, in the clinical surveillance group, the intended plan of surveillance was clinical examination and laboratory studies, and scans were obtained only to evaluate concerning signs or symptoms. Baseline patient characteristics, prognostic features, treatment records, and outcomes were collected. The primary objective was to compare overall survival for patients in both groups. For secondary objectives, we compared the success of second-line therapy and estimated the costs of imaging for each group. After 5 years of follow-up, the overall survival rate was 97% (95% confidence interval, 92%-99%) in the routine surveillance imaging group and 96% (95% confidence interval, 87%-99%) in the clinical surveillance group (P = .41). There were few relapses in each group, and all patients who relapsed in both groups achieved complete remission with second-line therapy. The charges associated with routine surveillance imaging were significantly higher than those for the clinical surveillance strategy, with no apparent clinical benefit. Clinical surveillance was not inferior to routine surveillance imaging in patients with cHL who achieved complete remission with frontline therapy. Routine

  11. Mobile Surveillance and Monitoring Robots

    International Nuclear Information System (INIS)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-01-01

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment

  12. Assessment of an outreach street-based HIV rapid testing programme as a strategy to promote early diagnosis: a comparison with two surveillance systems in Spain, 2008-2011.

    Science.gov (United States)

    Belza, M J; Hoyos, J; Fernández-Balbuena, S; Diaz, A; Bravo, M J; de la Fuente, L

    2015-04-09

    We assess the added value of a multisite, street-based HIV rapid testing programme by comparing its results to pre-existing services and assessing its potential to reduce ongoing transmission. Between 2008 and 2011, 8,923 individuals underwent testing. We compare outcomes with those of a network of 20 sexually transmitted infections (STI)/HIV clinics (EPI-VIH) and the Spanish National HIV Surveillance System (SNHSS); evaluate whether good visibility prompts testing and assess whether it reaches under-tested populations. 89.2% of the new infections were in men who have sex with men (MSM) vs 78.0% in EPI-VIH and 56.0% in SNHSS. 83.6% of the MSM were linked to care and 20.9% had VIH. 56.5% of the HIV-positive MSM tested because they happened to see the programme, 18.4% were previously untested and 26.3% had their last test ≥2 years ago. The programme provided linkage to care and early diagnosis mainly to MSM but attendees presented a lower HIV prevalence than EPI-VIH. From a cost perspective it would benefit from being implemented in locations highly frequented by MSM. Conversely, its good visibility led to reduced periods of undiagnosed infection in a high proportion of MSM who were not testing with the recommended frequency.

  13. Marginal Expense Oil Well Wireless Surveillance (MEOWWS)

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Donald G.

    2002-03-11

    The objective of this study was to identify and field test a new, low cost, wireless oil well surveillance system. A variety of suppliers and technologies were considered. One supplier and system was chosen that was low cost, new to the oil field, and successfully field tested.

  14. Atucha I nuclear power plant surveillance programme

    Energy Technology Data Exchange (ETDEWEB)

    Jinchuk, D [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1994-12-31

    After a review of the main characteristics of the Atucha I nuclear power plant and its pressure vessel, the embrittlement surveillance capsules and the irradiation conditions are described; Charpy impact tests and tensile tests were performed on the irradiated samples, and results are discussed and compared to theoretical calculations: transition temperature shifts, displacement per atom values. 6 refs., 16 figs., 7 tabs.

  15. Atucha I nuclear power plant surveillance programme

    International Nuclear Information System (INIS)

    Jinchuk, D.

    1993-01-01

    After a review of the main characteristics of the Atucha I nuclear power plant and its pressure vessel, the embrittlement surveillance capsules and the irradiation conditions are described; Charpy impact tests and tensile tests were performed on the irradiated samples, and results are discussed and compared to theoretical calculations: transition temperature shifts, displacement per atom values. 6 refs., 16 figs., 7 tabs

  16. Chaos on the interval

    CERN Document Server

    Ruette, Sylvie

    2017-01-01

    The aim of this book is to survey the relations between the various kinds of chaos and related notions for continuous interval maps from a topological point of view. The papers on this topic are numerous and widely scattered in the literature; some of them are little known, difficult to find, or originally published in Russian, Ukrainian, or Chinese. Dynamical systems given by the iteration of a continuous map on an interval have been broadly studied because they are simple but nevertheless exhibit complex behaviors. They also allow numerical simulations, which enabled the discovery of some chaotic phenomena. Moreover, the "most interesting" part of some higher-dimensional systems can be of lower dimension, which allows, in some cases, boiling it down to systems in dimension one. Some of the more recent developments such as distributional chaos, the relation between entropy and Li-Yorke chaos, sequence entropy, and maps with infinitely many branches are presented in book form for the first time. The author gi...

  17. Selection and evaluation of video tape recorders for surveillance applications

    International Nuclear Information System (INIS)

    Martinez, R.L.

    1988-01-01

    Unattended surveillance places unique requirements on video recorders. One such requireemnt, extended operational reliability, often cannot be determined from the manufacturers' data. Subsequent to market surveys and preliminary testing, the Sony 8mm EVO-210 recorder was selected for use in the Modular Integrated Video System (MIVS), while concurrently undergoing extensive reliability testing. A microprocessor based controller was developed to life test and evaluate the performance of the video cassette recorders. The controller has the capability to insert a unique binary count in the vertical interval of the recorder video signal for each scene. This feature allows for automatic verification of the recorded data using a MIVS Review Station. Initially, twenty recorders were subjected to the accelerated lift test, which involves recording one scene (eight video frames) every 15 seconds. The recorders were operated in the exact manner in which they are utilized in the MIVS. This paper describes the results of the preliminary testing, accelerated life test and the extensive testing on 130 Sony EVO-210 recorders

  18. Reviewing surveillance activities in nuclear power plants

    International Nuclear Information System (INIS)

    1989-03-01

    This document provides guidance to Operational Safety Review Teams (OSARTs) for reviewing surveillance activities at a nuclear power plant. In addition, the document contains reference material to support the review of surveillance activities, to assist within the Technical Support area and to ensure consistency between individual reviews. Drafts of the document have already been used on several OSART missions and found to be useful. The document first considers the objectives of an excellent surveillance programme. Investigations to determine the quality of the surveillance programme are then discussed. The attributes of an excellent surveillance programme are listed. Advice follows on how to phrase questions so as to obtain an informative response on surveillance features. Finally, specific equipment is mentioned that should be considered when reviewing functional tests. Four annexes provide examples drawn from operating nuclear power plants. They were selected to supplement the main text of the document with the best international practices as found in OSART reviews. They should in no way limit the acceptance and development of alternative approaches that lead to equivalent or better results. Refs, figs and tabs

  19. Interval methods: An introduction

    DEFF Research Database (Denmark)

    Achenie, L.E.K.; Kreinovich, V.; Madsen, Kaj

    2006-01-01

    This chapter contains selected papers presented at the Minisymposium on Interval Methods of the PARA'04 Workshop '' State-of-the-Art in Scientific Computing ''. The emphasis of the workshop was on high-performance computing (HPC). The ongoing development of ever more advanced computers provides...... the potential for solving increasingly difficult computational problems. However, given the complexity of modern computer architectures, the task of realizing this potential needs careful attention. A main concern of HPC is the development of software that optimizes the performance of a given computer....... An important characteristic of the computer performance in scientific computing is the accuracy of the Computation results. Often, we can estimate this accuracy by using traditional statistical techniques. However, in many practical situations, we do not know the probability distributions of different...

  20. Multichannel interval timer

    International Nuclear Information System (INIS)

    Turko, B.T.

    1983-10-01

    A CAMAC based modular multichannel interval timer is described. The timer comprises twelve high resolution time digitizers with a common start enabling twelve independent stop inputs. Ten time ranges from 2.5 μs to 1.3 μs can be preset. Time can be read out in twelve 24-bit words either via CAMAC Crate Controller or an external FIFO register. LSB time calibration is 78.125 ps. An additional word reads out the operational status of twelve stop channels. The system consists of two modules. The analog module contains a reference clock and 13 analog time stretchers. The digital module contains counters, logic and interface circuits. The timer has an excellent differential linearity, thermal stability and crosstalk free performance

  1. Experimenting with musical intervals

    Science.gov (United States)

    Lo Presto, Michael C.

    2003-07-01

    When two tuning forks of different frequency are sounded simultaneously the result is a complex wave with a repetition frequency that is the fundamental of the harmonic series to which both frequencies belong. The ear perceives this 'musical interval' as a single musical pitch with a sound quality produced by the harmonic spectrum responsible for the waveform. This waveform can be captured and displayed with data collection hardware and software. The fundamental frequency can then be calculated and compared with what would be expected from the frequencies of the tuning forks. Also, graphing software can be used to determine equations for the waveforms and predict their shapes. This experiment could be used in an introductory physics or musical acoustics course as a practical lesson in superposition of waves, basic Fourier series and the relationship between some of the ear's subjective perceptions of sound and the physical properties of the waves that cause them.

  2. QT interval prolongation associated with sibutramine treatment

    Science.gov (United States)

    Harrison-Woolrych, Mira; Clark, David W J; Hill, Geraldine R; Rees, Mark I; Skinner, Jonathan R

    2006-01-01

    Aims To investigate a possible association of sibutramine with QT interval prolongation. Methods Post-marketing surveillance using prescription event monitoring in the New Zealand Intensive Medicines Monitoring Programme (IMMP) identified a case of QT prolongation and associated cardiac arrest in a patient taking sibutramine for 25 days. This patient was further investigated, including genotyping for long QT syndrome. Other IMMP case reports suggesting arrhythmias associated with sibutramine were assessed and further reports were obtained from the World Health Organisation (WHO) adverse drug reactions database. Results The index case displayed a novel mutation in a cardiac potassium channel subunit gene, KCNQ1, which is likely to prolong cardiac membrane depolarization and increase susceptibility to long QT intervals. Assessment of further IMMP reports identified five additional patients who experienced palpitations associated with syncope or presyncopal symptoms, one of whom had a QTc at the upper limit of normal. Assessment of reports from the WHO database identified three reports of QT prolongation and one fatal case of torsade de pointes in a patient also taking cisapride. Conclusions This case series suggests that sibutramine may be associated with QT prolongation and related dysrhythmias. Further studies are required, but in the meantime we would recommend that sibutramine should be avoided in patients with long QT syndrome and in patients taking other medicines that may prolong the QT interval. PMID:16542208

  3. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  4. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  5. Reactor surveillance by noise analysis

    International Nuclear Information System (INIS)

    Ciftcioglu, Ozer

    1988-01-01

    A real-time noise analysis system is designed for the TRIGA reactor at Istanbul Technical University. By means of the noise techniques, reactor surveillance is performed together with failure diagnosis. The fast data processing is carried out by FFT in real-time so that malfunction or non-stationary operation of the reactor in long term can be identified by comparing the noise power spectra with the corresponding reference patterns while the decision making procedure is accomplished by the method of hypothesis testing. The system being computer based safety instrumentation involves CAMAC in conjunction with the RT-11 (PDP-11) single user dedicated environment. (author)

  6. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  7. Interpretando correctamente en salud pública estimaciones puntuales, intervalos de confianza y contrastes de hipótesis Accurate interpretation of point estimates, confidence intervals, and hypothesis tests in public health

    Directory of Open Access Journals (Sweden)

    Manuel G Scotto

    2003-12-01

    Full Text Available El presente ensayo trata de aclarar algunos conceptos utilizados habitualmente en el campo de investigación de la salud pública, que en numerosas situaciones son interpretados de manera incorrecta. Entre ellos encontramos la estimación puntual, los intervalos de confianza, y los contrastes de hipótesis. Estableciendo un paralelismo entre estos tres conceptos, podemos observar cuáles son sus diferencias más importantes a la hora de ser interpretados, tanto desde el punto de vista del enfoque clásico como desde la óptica bayesiana.This essay reviews some statistical concepts frequently used in public health research that are commonly misinterpreted. These include point estimates, confidence intervals, and hypothesis tests. By comparing them using the classical and the Bayesian perspectives, their interpretation becomes clearer.

  8. Duplex ultrasound surveillance after carotid artery endarterectomy.

    Science.gov (United States)

    Al Shakarchi, Julien; Lowry, Danielle; Nath, Jay; Khawaja, Aurangzaib Z; Inston, Nicholas; Tiwari, Alok

    2016-06-01

    After carotid endarterectomy (CEA), patients have been regularly followed up by duplex ultrasound imaging. However, the evidence for long-term follow-up is not clear, especially if the results from an early duplex scan are normal. This study assessed and systematically reviewed the evidence base for long-term surveillance after CEA and a normal early scan. Electronic databases were searched for studies assessing duplex surveillance after CEA in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome for this study was the incidence of restenosis after a normal early scan. The secondary outcome was the number of reinterventions after a normal early scan. The review included seven studies that reported 2317 procedures. Of those patients with a normal early scan, 2.8% (95% confidence interval, 0.7%-6%) developed a restenosis, and 0.4% (95% confidence interval, 0%-0.9%) underwent a reintervention for their restenosis during the follow-up period. This review confirms that routine postoperative duplex ultrasound surveillance after CEA is not necessary if the early duplex scan is normal. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Surveillance extension experience at WWER-440 type reactors

    International Nuclear Information System (INIS)

    Gillemot, F.; Uri, G.; Oszwald, F.; Trampus, P.

    1993-01-01

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs

  10. Surveillance extension experience at WWER-440 type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gillemot, F; Uri, G [Budapesti Mueszaki Egyetem, Budapest (Hungary); Oszwald, F; Trampus, P

    1994-12-31

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs.

  11. Surveillance dosimetry of operating power plants

    International Nuclear Information System (INIS)

    McElroy, W.N.; Davis, A.I.; Gold, R.

    1981-01-01

    The main focus of the research efforts presently underway is the LWR power reactor surveillance program in which metallurgical test specimens of the reactor PV and dosimetry sensors are placed in three or more surveillance capsules at or near the reactor PV inner wall. They are then irradiated in a temperature and neutron flux-spectrum environment as similar as possible to the PV itself for periods of about 1.5 to 15 effective full-power years (EFPY), with removal of the last capsule at a fluence corresponding to the 30- to 40-year plant end-of-life (EOL) fluence. Because the neutron flux level at the surveillance position is greater than at the vessel, the test is accelerated wit respect to the vessel exposure, allowing early assessment of EOL conditions

  12. Workers' health surveillance: implementation of the Directive 89/391/EEC in Europe

    NARCIS (Netherlands)

    Colosio, C.; Mandic-Rajcevic, S.; Godderis, L.; van der Laan, G.; Hulshof, C.; van Dijk, F.

    2017-01-01

    Background European Union (EU) Directive 89/391 addressed occupational health surveillance, which recommends to provide workers with `access to health surveillance at regular intervals', aiming to prevent work-related and occupational diseases. Aims To investigate how EU countries adopted this

  13. Health & Demographic Surveillance System profile: the Muzaffarpur-TMRC Health and Demographic Surveillance System.

    Science.gov (United States)

    Malaviya, Paritosh; Picado, Albert; Hasker, Epco; Ostyn, Bart; Kansal, Sangeeta; Singh, Rudra Pratap; Shankar, Ravi; Boelaert, Marleen; Sundar, Shyam

    2014-10-01

    The Muzaffarpur-TMRC Health and Demographic Surveillance System (HDSS), established in 2007, was developed as an enlargement of the scope of a research collaboration on the project Visceral Leishmaniasis in Bihar, which had been ongoing since 2005. The HDSS is located in a visceral leishmaniasis (VL)-endemic area in the Muzaffarpur district of Bihar state in India. It is the only HDSS conducting research on VL, which is a vector-borne infectious disease transmitted by female phlebotomine sandflies and is fatal if left untreated. Currently the HDSS serves a population of over 105,000 in 66 villages. The HDSS collects data on vital events including pregnancies, births, deaths, migration and marriages, as well as other socio-economic indicators, at regular intervals. Incident VL cases are identified. The HDSS team is experienced in conducting both qualitative and quantitative studies, sample collection and rapid diagnostic tests in the field. In each village, volunteers connect the HDSS team with the community members. The Muzaffarpur-TMRC HDSS provides opportunities for studies on VL and other neglected tropical diseases (NTDs) and their interaction with demographic events such as migration. Queries related to research collaborations and data sharing can be sent to Dr Shyam Sundar at [drshyamsundar@hotmail.com]. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  14. A nurse-led model at public academic hospitals maintains high adherence to colorectal cancer surveillance guidelines.

    Science.gov (United States)

    Symonds, Erin L; Simpson, Kalindra; Coats, Michelle; Chaplin, Angela; Saxty, Karen; Sandford, Jayne; Young Am, Graeme P; Cock, Charles; Fraser, Robert; Bampton, Peter A

    2018-06-18

    To examine the compliance of colorectal cancer surveillance decisions for individuals at greater risk with current evidence-based guidelines and to determine whether compliance differs between surveillance models. Prospective auditing of compliance of surveillance decisions with evidence-based guidelines (NHMRC) in two decision-making models: nurse coordinator-led decision making in public academic hospitals and physician-led decision making in private non-academic hospitals. Selected South Australian hospitals participating in the Southern Co-operative Program for the Prevention of Colorectal Cancer (SCOOP). Proportions of recall recommendations that matched NHMRC guideline recommendations (March-May 2015); numbers of surveillance colonoscopies undertaken more than 6 months ahead of schedule (January-December 2015); proportions of significant neoplasia findings during the 15 years of SCOOP operation (2000-2015). For the nurse-led/public academic hospital model, the recall interval recommendation following 398 of 410 colonoscopies (97%) with findings covered by NHMRC guidelines corresponded to the guideline recommendations; for the physician-led/private non-academic hospital model, this applied to 257 of 310 colonoscopies (83%) (P < 0.001). During 2015, 27% of colonoscopies in public academic hospitals (mean, 27 months; SD, 13 months) and 20% of those in private non-academic hospitals (mean, 23 months; SD, 12 months) were performed more than 6 months earlier than scheduled, in most cases because of patient-related factors (symptoms, faecal occult blood test results). The ratio of the numbers of high risk adenomas to cancers increased from 6.6:1 during 2001-2005 to 16:1 during 2011-2015. The nurse-led/public academic hospital model for decisions about colorectal cancer surveillance intervals achieves a high degree of compliance with guideline recommendations, which should relieve burdening of colonoscopy resources.

  15. The plays and arts of surveillance: studying surveillance as entertainment

    NARCIS (Netherlands)

    Albrechtslund, Anders; Dubbeld, L.

    2006-01-01

    This paper suggests a direction in the development of Surveillance Studies that goes beyond current attention for the caring, productive and enabling aspects of surveillance practices. That is, surveillance could be considered not just as positively protective, but even as a comical, playful,

  16. Reviewing interval cancers: Time well spent?

    International Nuclear Information System (INIS)

    Gower-Thomas, Kate; Fielder, Hilary M.P.; Branston, Lucy; Greening, Sarah; Beer, Helen; Rogers, Cerilan

    2002-01-01

    OBJECTIVES: To categorize interval cancers, and thus identify false-negatives, following prevalent and incident screens in the Welsh breast screening programme. SETTING: Breast Test Wales (BTW) Llandudno, Cardiff and Swansea breast screening units. METHODS: Five hundred and sixty interval breast cancers identified following negative mammographic screening between 1989 and 1997 were reviewed by eight screening radiologists. The blind review was achieved by mixing the screening films of women who subsequently developed an interval cancer with screen negative films of women who did not develop cancer, in a ratio of 4:1. Another radiologist used patients' symptomatic films to record a reference against which the reviewers' reports of the screening films were compared. Interval cancers were categorized as 'true', 'occult', 'false-negative' or 'unclassified' interval cancers or interval cancers with minimal signs, based on the National Health Service breast screening programme (NHSBSP) guidelines. RESULTS: Of the classifiable interval films, 32% were false-negatives, 55% were true intervals and 12% occult. The proportion of false-negatives following incident screens was half that following prevalent screens (P = 0.004). Forty percent of the seed films were recalled by the panel. CONCLUSIONS: Low false-negative interval cancer rates following incident screens (18%) versus prevalent screens (36%) suggest that lower cancer detection rates at incident screens may have resulted from fewer cancers than expected being present, rather than from a failure to detect tumours. The panel method for categorizing interval cancers has significant flaws as the results vary markedly with different protocol and is no more accurate than other, quicker and more timely methods. Gower-Thomas, K. et al. (2002)

  17. Developing a surveillance system for HIV/AIDS in Pakistan

    International Nuclear Information System (INIS)

    Emmanuel, F.; Bokhari, A.

    2006-01-01

    Apart from other interventions, surveillance remains a major focus of the national response to HIV/AIDS. However, with a shift in the epidemic pattern, the existing surveillance strategies are barely insufficient and long-term structural changes are desirable. This article provides a conceptual framework for developing a scientific system for HIV surveillance in Pakistan. Second generation surveillance system including repeated cross-sectional surveys in high risk population groups are suggested to collect behavioral and serological data at regular intervals on an annual basis to monitor the epidemic trend as well as the associated behaviors. In addition, multiple data resources have been highlighted, which could be coordinated to describe the epidemic pattern in the country. This information should form the basis for national prevention planning and ought to be used for making sensible choices through which prevention efforts are most likely to reduce new infections. (author)

  18. Conic surveillance evasion

    NARCIS (Netherlands)

    Lewin, J.; Olsder, G.J.

    1979-01-01

    A surveillance-evasion differential game of degree with a detection zone in the shape of a two-dimensional cone is posed. The nature of the optimal strategies and the singular phenomena of the value function are described and correlated to subsets of the space of all possible parameter combinations,

  19. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.; Hammer, J.

    1988-01-01

    The development progress during the reporting period 1988 of the laser surveillance system of spent fuel pools is summarized. The present engineered system comes close to a final version for field application as all technical questions have been solved in 1988. 14 figs., 1 tab. (Author)

  20. Infectieziekten Surveillance Informatie Systeem

    NARCIS (Netherlands)

    Sprenger MJW; van Pelt W; CIE

    1994-01-01

    In the Netherlands an electronic network has been proposed for structured data transfer and communication concerning the control of infectious diseases. This project has been baptized ISIS (Infectious diseases Surveillance Information System). It is an initiative of the Dutch Government. ISIS

  1. Surveillance and Communication

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Albrechtslund, Anders; Lauritsen, Peter

    2017-01-01

    , and acquaintances are up to on social media. In turn, they also leave trails of digital footprints that may be collected and analyzed by governments, businesses, or hackers. The imperceptible nature of this new surveillance raises some pressing concerns about our digital lives as our data doubles increasingly...

  2. New containment and surveillance portal monitor data analysis methed

    International Nuclear Information System (INIS)

    Henry, C.N.; Pratt, J.C.

    1979-01-01

    A new containment and surveillance portal monitor data analysis method has been developed. Current approaches use only the data from a single passage and an average background interval for alarm determination. The new method improves performance by summing the counts from many passages for comparison to the expected count, thus improving the statistical accuracy

  3. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos

    2012-01-01

    The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutiv...

  4. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    NARCIS (Netherlands)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos; Fernandez-Vozmediano, José M; Ayala, Fabio; Balato, Anna; Bauer, Andrea; Ballmer-Weber, Barbara; Beliauskiene, Aiste; Fortina, Anna Belloni; Bircher, Andreas; Brasch, Jochen; Chowdhury, Mahbub M U; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise; Cooper, Sue; Czarnecka-Operacz, Magda; Zmudzinska, Maria; Elsner, Peter; English, John S C; Frosch, Peter J; Fuchs, Thomas; García-Gavín, Juan; Fernández-Redondo, Virginia; Gawkrodger, David J; Giménez-Arnau, Ana; Green, Cathy M; Horne, Helen L; Johansen, Jeanne Duus; Jolanki, Riitta; Pesonen, Maria; King, Clodagh M; Krêcisz, Beata; Chomiczewska, Dorota; Kiec-Swierczynska, Marta; Larese, Francesca; Mahler, Vera; Ormerod, Anthony D; Peserico, Andrea; Rantanen, Tapio; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Sansom, Jane E; Silvestre, Juan Fco; Simon, Dagmar; Spiewak, Radoslaw; Statham, Barry N; Stone, Natalie; Wilkinson, Mark; Schnuch, Axel

    BACKGROUND: The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in

  5. Extended surveillance as a support to PLIM

    International Nuclear Information System (INIS)

    Walle, Eric van

    2002-01-01

    Full text: The safe exploitation of the reactor pressure vessel was and is always a major concern in nuclear power plant life management. At present, issues like Plant Life Extension, where utilities look into the possibility of license renewal after 40 years of operation, are becoming relevant in the USA. In other countries PLIM beyond the design life of the NPP could also be desirable from the economic viewpoint. The limiting factor could, however, be the integrity of the reactor pressure vessel. The reactor pressure vessel surveillance procedures as defined by regulatory legislation is limited and can be supplemented with valuable information that can be extracted in parallel to conventional surveillance testing or through additional testing on surveillance material. This is justified for several reasons: 1. The current methodology is semi-empirical, contains flaws and is in a number of cases over conservative. Without giving in on safety, we need to try and understand the material behavior more fundamentally; 2. Some reactor surveillance materials demonstrate inconsistent behavior with respect to the overall trend. These materials are called 'outlier' materials. But are they really outliers or is this connected to the indexing methodology used? 3. Additional data, for example the results of instrumented Charpy-V impact tests, have been obtained on many surveillance test specimens and are not adequately exploited in the actual surveillance methodology; 4. Scientific research provides substantial information and understanding of degradation mechanisms in reactor pressure vessel steels. Although we will not concentrate on this topic, the development of powerful microscopic investigation techniques, like FEGSTEM, APFIM, SANS, positron annihilation, internal friction, ... led to an intensified development of radiation damage modelling and are an input to micromechanical modelling. Moreover, due to the ever increasing computer power, additional multi-scale (time and

  6. Survey of Clostridium difficile infection surveillance systems in Europe, 2011.

    Science.gov (United States)

    Kola, Axel; Wiuff, Camilla; Akerlund, Thomas; van Benthem, Birgit H; Coignard, Bruno; Lyytikäinen, Outi; Weitzel-Kage, Doris; Suetens, Carl; Wilcox, Mark H; Kuijper, Ed J; Gastmeier, Petra

    2016-07-21

    To develop a European surveillance protocol for Clostridium difficile infection (CDI), existing national CDI surveillance systems were assessed in 2011. A web-based electronic form was provided for all national coordinators of the European CDI Surveillance Network (ECDIS-Net). Of 35 national coordinators approached, 33 from 31 European countries replied. Surveillance of CDI was in place in 14 of the 31 countries, comprising 18 different nationwide systems. Three of 14 countries with CDI surveillance used public health notification of cases as the route of reporting, and in another three, reporting was limited to public health notification of cases of severe CDI. The CDI definitions published by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and the European Centre for Disease Prevention and Control (ECDC) were widely used, but there were differing definitions to distinguish between community- and healthcare-associated cases. All CDI surveillance systems except one reported annual national CDI rates (calculated as number of cases per patient-days). Only four surveillance systems regularly integrated microbiological data (typing and susceptibility testing results). Surveillance methods varied considerably between countries, which emphasises the need for a harmonised European protocol to allow consistent monitoring of the CDI epidemiology at European level. The results of this survey were used to develop a harmonised EU-wide hospital-based CDI surveillance protocol. This article is copyright of The Authors, 2016.

  7. Epidemiological Concepts Regarding Disease Monitoring and Surveillance

    Directory of Open Access Journals (Sweden)

    Christensen Jette

    2001-03-01

    Full Text Available Definitions of epidemiological concepts regarding disease monitoring and surveillance can be found in textbooks on veterinary epidemiology. This paper gives a review of how the concepts: monitoring, surveillance, and disease control strategies are defined. Monitoring and surveillance systems (MO&SS involve measurements of disease occurrence, and the design of the monitoring determines which types of disease occurrence measures can be applied. However, the knowledge of the performance of diagnostic tests (sensitivity and specificity is essential to estimate the true occurrence of the disease. The terms, disease control programme (DCP or disease eradication programme (DEP, are defined, and the steps of DCP/DEP are described to illustrate that they are a process rather than a static MO&SS.

  8. MARGINAL EXPENSE OIL WELL WIRELESS SURVEILLANCE MEOWS

    Energy Technology Data Exchange (ETDEWEB)

    Mason M. Medizade; John R. Ridgely; Donald G. Nelson

    2004-11-01

    A marginal expense oil well wireless surveillance system to monitor system performance and production from rod-pumped wells in real time from wells operated by Vaquero Energy in the Edison Field, Main Area of Kern County in California has been successfully designed and field tested. The surveillance system includes a proprietary flow sensor, a programmable transmitting unit, a base receiver and receiving antenna, and a base station computer equipped with software to interpret the data. First, the system design is presented. Second, field data obtained from three wells is shown. Results of the study show that an effective, cost competitive, real-time wireless surveillance system can be introduced to oil fields across the United States and the world.

  9. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools (SFSP's) will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a full size laser system operating in air and have used an array of 6 zircaloy BWR tubes to simulate an assembly. The reflective signal from the zircaloy rods is a strong function of position of the assembly, but in all cases is easily discernable from the reference scan of the background with no assembly. A design for a SFSP laser surveillance system incorporating laser ranging is discussed. 10 figures

  10. Routine airway surveillance in pediatric tracheostomy patients.

    Science.gov (United States)

    Gergin, Ozgul; Adil, Eelam; Kawai, Kosuke; Watters, Karen; Moritz, Ethan; Rahbar, Reza

    2017-06-01

    The aim of this study is to review airway findings in children with tracheostomies who underwent surveillance direct laryngoscopy and bronchoscopy (DLB) to determine the yield of routine airway evaluation in these patients. Retrospective chart review at tertiary referral children's hospital. A retrospective chart review was conducted of all of the children with tracheostomies who underwent DLB after tracheostomy between 1984 and 2015. A total of 303 patients met inclusion criteria. The median time interval between tracheostomy and first follow-up DLB was 12.0 months (IQR 4.8-28.9 months). There was no significant difference in the incidence of airway lesions between patients who underwent endoscopy tracheostomy versus those who had a longer time interval between tracheostomy and DLB (p = 0.16). One hundred sixty seven patients (55.1%) were diagnosed with lesions, with suprastomal granulation (39.9%) being the most common. Symptomatic patients were significantly more likely to have an airway lesion identified (69.9% versus 42.0%; p tracheostomy were significantly more likely to have an airway lesion (p = 0.01). The high incidence of airway lesions noted during surveillance DLB support the utility of routine airway endoscopy in pediatric tracheostomy patients. Symptomatic patients, those with ventilator dependence, or cardiopulmonary or trauma indications for tracheostomy are more likely to have airway lesions and should be monitored closely. The ideal time interval between surveillance endoscopies needs to be examined further. Copyright © 2017. Published by Elsevier B.V.

  11. A Pilot Study to Increase the Efficiency of HIV Outreach Testing Through the Use of Timely and Geolocated HIV Viral Load Surveillance Data

    Science.gov (United States)

    Jennings, Jacky M.; Schumacher, Christina; Perin, Jamie; Myers, Tanya; Fields, Nathan; Greiner Safi, Amelia; Chaulk, Patrick

    2018-01-01

    Background Eliminating HIV transmission in a population necessitates identifying population reservoirs of HIV infection and subgroups most likely to transmit. HIV viral load is the single most important predictor of HIV transmission. The objective of this analysis was to evaluate whether a public health practice pilot project based on community viral load resulted in increases in the proportion of time spent testing in high viral load areas (process measure) and 3 outcome measures—the number and percent of overall HIV diagnoses, new diagnoses, and high viral load positives—in one mid-Atlantic US city with a severe HIV epidemic. Methods The evaluation was conducted during three, 3-month periods for 3 years and included the use of community viral load, global positioning system tracking data, and statistical testing to evaluate the effectiveness of the pilot project. Results The proportion of time spent outreach testing in high viral load areas (69%–84%, P the overall number and percent of HIV positives ((60 (3%) to 127 (6%), P The number and percent of new diagnoses (3 (0.1%) to 6 (0.2%)) and high viral load positives (5 (0.2%) to 9 (0.4%)) increased, but the numbers were too small for statistical testing. Discussion These results suggest that using community viral load to increase the efficiency of HIV outreach testing is feasible and may be effective in identifying more HIV positives. The pilot project provides a model for other public health practice demonstration projects. PMID:29420450

  12. A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

    International Nuclear Information System (INIS)

    Guo, Junfeng; Newell, John D.; Wang, Chao; Chan, Kung-Sik; Jin, Dakai; Saha, Punam K.; Sieren, Jered P.; Barr, R. G.; Han, MeiLan K.; Kazerooni, Ella; Cooper, Christopher B.; Couper, David; Hoffman, Eric A.

    2016-01-01

    Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS

  13. A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Junfeng; Newell, John D. [Departments of Radiology and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242 (United States); Wang, Chao; Chan, Kung-Sik [Department of Statistics and Actuarial Science, University of Iowa, Iowa City, Iowa 52242 (United States); Jin, Dakai; Saha, Punam K. [Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa 52242 (United States); Sieren, Jered P. [Department of Radiology, University of Iowa, Iowa City, Iowa 52242 (United States); Barr, R. G. [Departments of Medicine and Epidemiology, Columbia University Medical Center, New York, New York 10032 (United States); Han, MeiLan K. [Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan 48109 (United States); Kazerooni, Ella [Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Cooper, Christopher B. [Department of Medicine, University of California, Los Angeles, California 90095 (United States); Couper, David [Department of Biostatistics, University of North Carolina, Chapel Hill, North Carolina 27599 (United States); Hoffman, Eric A., E-mail: eric-hoffman@uiowa.edu [Departments of Radiology, Medicine and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242 (United States)

    2016-05-15

    Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS

  14. Video surveillance using distance maps

    Science.gov (United States)

    Schouten, Theo E.; Kuppens, Harco C.; van den Broek, Egon L.

    2006-02-01

    Human vigilance is limited; hence, automatic motion and distance detection is one of the central issues in video surveillance. Hereby, many aspects are of importance, this paper specially addresses: efficiency, achieving real-time performance, accuracy, and robustness against various noise factors. To obtain fully controlled test environments, an artificial development center for robot navigation is introduced in which several parameters can be set (e.g., number of objects, trajectories and type and amount of noise). In the videos, for each following frame, movement of stationary objects is detected and pixels of moving objects are located from which moving objects are identified in a robust way. An Exact Euclidean Distance Map (E2DM) is utilized to determine accurately the distances between moving and stationary objects. Together with the determined distances between moving objects and the detected movement of stationary objects, this provides the input for detecting unwanted situations in the scene. Further, each intelligent object (e.g., a robot), is provided with its E2DM, allowing the object to plan its course of action. Timing results are specified for each program block of the processing chain for 20 different setups. So, the current paper presents extensive, experimentally controlled research on real-time, accurate, and robust motion detection for video surveillance, using E2DMs, which makes it a unique approach.

  15. SCORPIO - WWER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, Arne; Bodal, Terje; Sunde, Svein; Zalesky, K.; Lehman, M.; Pecka, M.; Svarny, J.; Krysl, V.; Juzova, Z.; Sedlak, A.; Semmler, M.

    1998-01-01

    The Institut for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(Authors)

  16. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, A.; Bodal, T.; Sunde, S.

    1998-01-01

    The Institutt for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators, which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including VVERs. The main differences between VVERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a VVER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(author)

  17. 46 CFR 61.20-17 - Examination intervals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Examination intervals. 61.20-17 Section 61.20-17... INSPECTIONS Periodic Tests of Machinery and Equipment § 61.20-17 Examination intervals. (a) A lubricant that... examination interval. (b) Except as provided in paragraphs (c) through (f) of this section, each tailshaft on...

  18. Surface-water surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Saldi, K.A.; Dirkes, R.L.; Blanton, M.L.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the Surface water on and near the Hanford Site is monitored to determine the potential effects of Hanford operations. Surface water at Hanford includes the Columbia River, riverbank springs, ponds located on the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site. Columbia River sediments are also included in this discussion. Tables 5.3.1 and 5.3.2 summarize the sampling locations, sample types, sampling frequencies, and sample analyses included in surface-water surveillance activities during 1994. Sample locations are also identified in Figure 5.3.1. This section describes the surveillance effort and summarizes the results for these aquatic environments. Detailed analytical results are reported by Bisping (1995).

  19. Water radiological surveillance (II)

    International Nuclear Information System (INIS)

    Pablo San Martin de, M.

    2008-01-01

    This paper summarizes the characteristics of the Environmental Surveillance Radiological Networks (ESRN) currently operating in CEDEX. In the first part, the Spanish Continental Waters ESRN has been presented. This second one describes Spanish Costal Waters ESRN and the High Sensitivity Networks in Continental and Marine Waters. It also presents the Radiological Surveillance of Drinking Waters that CEDEX carries out in waters of public consumption management by the Canal de Isabel II (CYII) and by the Mancomunity of Canals Taibilla (M.C.T.). The legislation applicable in each case is reviewed as well. Due to its extension the article has been divided into two parts. As Spanish Continental Waters ESRN has been reviewed in the first part, the others ESRN are discussed in this second one. (Author) 10 refs

  20. Disaster prevention surveillance system

    International Nuclear Information System (INIS)

    Nara, Satoru; Kamiya, Eisei

    2001-01-01

    Fuji Electric Co., Ltd. has supplied many management systems to nuclear reactor institution. 'The nuclear countermeasures-against-calamities special-measures' was enforced. A nuclear entrepreneur has devised the measure about expansion prevention and restoration of a calamity while it endeavors after prevention of generating of a nuclear calamity. Our company have supplied the 'disaster prevention surveillance system' to the Japan Atomic Energy Research Institute Tokai Research Establishment aiming at strengthening of the monitoring function at the time (after the accident) of the accident used as one of the above-mentioned measures. A 'disaster prevention surveillance system' can share the information on the accident spot in an on-site command place, an activity headquarters, and support organizations, when the serious accident happens. This system is composed of various sensors (temperature, pressure and radiation), cameras, computers and network. (author)

  1. Surface-water surveillance

    International Nuclear Information System (INIS)

    Saldi, K.A.; Dirkes, R.L.; Blanton, M.L.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the Surface water on and near the Hanford Site is monitored to determine the potential effects of Hanford operations. Surface water at Hanford includes the Columbia River, riverbank springs, ponds located on the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site. Columbia River sediments are also included in this discussion. Tables 5.3.1 and 5.3.2 summarize the sampling locations, sample types, sampling frequencies, and sample analyses included in surface-water surveillance activities during 1994. Sample locations are also identified in Figure 5.3.1. This section describes the surveillance effort and summarizes the results for these aquatic environments. Detailed analytical results are reported by Bisping (1995)

  2. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  3. Medical Surveillance Monthly Report

    Science.gov (United States)

    2016-12-01

    Illness Prevention and Sun Safety. “Sun Safety.” https:// phc.amedd.army.mil/ topics /discond/hipss/Pages/ SunSafety.aspx. Accessed on 7 December 2016. 22...febrile illness; however, after its wide- spread introduction into immunologically MSMR Vol. 23 No. 12 December 2016 Page 8 naïve populations, a...October 2016 (data as of 22 November 2016) MSMR’s Invitation to Readers Medical Surveillance Monthly Report (MSMR) invites readers to submit topics for

  4. The analysis of reactor vessel surveillance program data

    International Nuclear Information System (INIS)

    Norris, E.B.

    1979-01-01

    Commercial nuclear power reactor vessel surveillance programs are provided by the reactor supplier and are designed to meet the requirements of ASTM Method E 185. (3). Each surveillance capsule contains sets of Charpy V-notch (Csub(v)) specimens representing selected materials from the vessel beltline region and some reference steel, tension test specimens machined from selected beltline materials, temperature monitors, and neutron flux dosimeters. Surveillance capsules may also contain fracture mechanics specimens machined from selected vessel beltline materials. The major steps in the conduct of a surveillance program include (1) the testing of the surveillance specimens to determine the exposure conditions at the capsule location and the resulting embrittlement of the vessel steel, (2) the extrapolation of the capsule results to the pressure vessel wall, and (3) the determination of the heatup and cooldown limits for normal, upset, and test operation. This paper will present data obtained from commercial light water reactor surveillance programs to illustrate the methods of analysis currently in use at Southwest Research Institute and to demonstrate some of the limitations imposed by the data available. Details concerning the procedures for testing the surveillance capsule specimens will not be included because they are considered to be outside of the scope of this paper

  5. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  6. History of trichinellosis surveillance

    Directory of Open Access Journals (Sweden)

    Blancou J.

    2001-06-01

    Full Text Available The origin of trichinellosis, which existed in ancient times as testified by the discovery of parasite larvae on an Egyptian mummy, unfolded in several stages: discovery of encapsulated larvae (in the 1820s, identification and scientific description of these larvae (Paget Owen, 1835, followed by experimental infestations of animals (dogs, pigs, rabbits, mice or of humans as from 1850.The main occurrences of trichinellosis were followed with particular attention in Europe (Germany, Denmark, France, etc. and in the United States of America at the end of the XIXth century. They affected numerous domestic animal species (pigs, horses, etc. or wildlife and humans. Germany paid the heaviest toll with regard to the disease in humans, between 1860 and 1880, with several thousands of patients and more than 500 deaths.Different trichinellosis surveillance systems were set up in the relevant countries in the 1860s. In humans, this surveillance was carried out on affected living patients by a biopsy of the biceps muscles and subsequently by an analysis of eosinophilia (1895. In animals, surveillance was for a long time solely based on postmortem examination of the muscles of the affected animals. This method was used for the first time in 863 in Germany, and from the 1 890s, on several hundreds of thousands of pigs in Europe or in the United States of America.

  7. Congenital rubella syndrome surveillance as a platform for surveillance of other congenital infections, Peru, 2004-2007.

    Science.gov (United States)

    Whittembury, Alvaro; Galdos, Jorge; Lugo, María; Suárez-Ognio, Luis; Ortiz, Ana; Cabezudo, Edwin; Martínez, Mario; Castillo-Solórzano, Carlos; Andrus, Jon Kim

    2011-09-01

    Rubella during pregnancy can cause serious fetal abnormalities and death. Peru has had integrated measles/rubella surveillance since 2000 but did not implement congenital rubella syndrome (CRS) surveillance until 2004, in accordance with the Pan American Health Organization recommendations for rubella elimination. The article describes the experience from the CRS sentinel surveillance system in Peru. Peru has maintained a national sentinel surveillance system for reporting confirmed and suspected CRS cases since 2004. A surveillance protocol was implemented with standardized case definitions and instruments in the selected sentinel sites. Each sentinel site completes their case investigations and report forms and sends the reports to the Health Region Epidemiology Department, which forwards the data to the national Epidemiology Department. CRS surveillance data were analyzed for the period 2004-2007. During the period 2004-2007, 16 health facilities, which are located in 9 of the 33 health regions, representing the 3 main geographical areas (coast, mountain, and jungle), were included as sentinel sites for the CRS surveillance. A total of 2061 suspected CRS cases were reported to the system. Of these, 11 were classified as CRS and 23 as congenital rubella infection. Factors significantly associated with rubella vertical transmission were: (1) in the mother, maternal history of rash during pregnancy (odds ratio [OR], 12.0; 95% confidence interval [CI], 3.8-37.8); (2) and in the infant, pigmentary retinopathy (OR, 18.4; 95% CI, 3.2-104.6), purpura (OR, 14.7; 95% CI, 2.8-78.3), and developmental delay (OR, 4.4; 95% CI, 1.75-11.1). The surveillance system has been able to identify rubella vertical transmission, reinforcing the evidence that rubella was a public health problem in Peru. This system may serve as a platform to implement surveillance for other congenital infections in Peru.

  8. Recurrence interval analysis of trading volumes.

    Science.gov (United States)

    Ren, Fei; Zhou, Wei-Xing

    2010-06-01

    We study the statistical properties of the recurrence intervals τ between successive trading volumes exceeding a certain threshold q. The recurrence interval analysis is carried out for the 20 liquid Chinese stocks covering a period from January 2000 to May 2009, and two Chinese indices from January 2003 to April 2009. Similar to the recurrence interval distribution of the price returns, the tail of the recurrence interval distribution of the trading volumes follows a power-law scaling, and the results are verified by the goodness-of-fit tests using the Kolmogorov-Smirnov (KS) statistic, the weighted KS statistic and the Cramér-von Mises criterion. The measurements of the conditional probability distribution and the detrended fluctuation function show that both short-term and long-term memory effects exist in the recurrence intervals between trading volumes. We further study the relationship between trading volumes and price returns based on the recurrence interval analysis method. It is found that large trading volumes are more likely to occur following large price returns, and the comovement between trading volumes and price returns is more pronounced for large trading volumes.

  9. Twelve years of fireworks market surveillance in France

    OpenAIRE

    Branka , Ruddy

    2012-01-01

    International audience; In the view of market surveillance, more than 4400 fireworks have been taken on the spot by sworn people or bought on the market in France since 1999 for inspection purposes. This paper presents the market surveillance sampling evolution during twelve years, carried out by the PYRO unit of the Accidental Risks Division of INERIS as testing body ; the related measures implemented : additional audits in importer plants, interlaboratory tests for guarantying the reliabili...

  10. Diagnostic interval and mortality in colorectal cancer

    DEFF Research Database (Denmark)

    Tørring, Marie Louise; Frydenberg, Morten; Hamilton, William

    2012-01-01

    Objective To test the theory of a U-shaped association between time from the first presentation of symptoms in primary care to the diagnosis (the diagnostic interval) and mortality after diagnosis of colorectal cancer (CRC). Study Design and Setting Three population-based studies in Denmark...

  11. Learned Interval Time Facilitates Associate Memory Retrieval

    Science.gov (United States)

    van de Ven, Vincent; Kochs, Sarah; Smulders, Fren; De Weerd, Peter

    2017-01-01

    The extent to which time is represented in memory remains underinvestigated. We designed a time paired associate task (TPAT) in which participants implicitly learned cue-time-target associations between cue-target pairs and specific cue-target intervals. During subsequent memory testing, participants showed increased accuracy of identifying…

  12. Twitter Influenza Surveillance: Quantifying Seasonal Misdiagnosis Patterns and their Impact on Surveillance Estimates.

    Science.gov (United States)

    Mowery, Jared

    2016-01-01

    Influenza (flu) surveillance using Twitter data can potentially save lives and increase efficiency by providing governments and healthcare organizations with greater situational awareness. However, research is needed to determine the impact of Twitter users' misdiagnoses on surveillance estimates. This study establishes the importance of Twitter users' misdiagnoses by showing that Twitter flu surveillance in the United States failed during the 2011-2012 flu season, estimates the extent of misdiagnoses, and tests several methods for reducing the adverse effects of misdiagnoses. Metrics representing flu prevalence, seasonal misdiagnosis patterns, diagnosis uncertainty, flu symptoms, and noise were produced using Twitter data in conjunction with OpenSextant for geo-inferencing, and a maximum entropy classifier for identifying tweets related to illness. These metrics were tested for correlations with World Health Organization (WHO) positive specimen counts of flu from 2011 to 2014. Twitter flu surveillance erroneously indicated a typical flu season during 2011-2012, even though the flu season peaked three months late, and erroneously indicated plateaus of flu tweets before the 2012-2013 and 2013-2014 flu seasons. Enhancements based on estimates of misdiagnoses removed the erroneous plateaus and increased the Pearson correlation coefficients by .04 and .23, but failed to correct the 2011-2012 flu season estimate. A rough estimate indicates that approximately 40% of flu tweets reflected misdiagnoses. Further research into factors affecting Twitter users' misdiagnoses, in conjunction with data from additional atypical flu seasons, is needed to enable Twitter flu surveillance systems to produce reliable estimates during atypical flu seasons.

  13. Guidelines for the medical surveillance of atomic radiation workers

    International Nuclear Information System (INIS)

    1991-11-01

    These guidelines are provided for the use and guidance of occupational physicians concerned with the medical surveillance of atomic radiation workers (ARWs). Persons employed in industries where there is exposure to ionizing radiation should be screened medically for fitness for certain jobs before starting such work and at appropriate intervals while employed. This includes workers at uranium mines, mills and refineries, nuclear fuel fabrication plants, nuclear power plants and research facilities, and facilities using radionuclides in an industrial setting. An important purpose of medical surveillance is to ensure that workers are fit both physically and psychologically to undertake the tasks they may be called upon to perform

  14. Patch test results of the European baseline series among patients with occupational contact dermatitis across Europe - analyses of the European Surveillance System on Contact Allergy network, 2002-2010.

    Science.gov (United States)

    Pesonen, Maria; Jolanki, Riitta; Larese Filon, Francesca; Wilkinson, Mark; Kręcisz, Beata; Kieć-Świerczyńska, Marta; Bauer, Andrea; Mahler, Vera; John, Swen M; Schnuch, Axel; Uter, Wolfgang

    2015-03-01

    Occupational contact dermatitis is one of the most common occupational diseases in Europe. In order to develop effective preventive measures, detailed and up-to-date data on the incidence, main causes and professions at risk of occupational contact dermatitis are needed. To describe the pattern of patch test reactivity to allergens in the European baseline series of patients with occupational contact dermatitis in different occupations. We analysed data collected by the European Surveillance System on Contact Allergy (ESSCA) network from 2002 to 2010, from 11 European countries. Allergens in the European baseline series associated with an at least doubled risk of occupational contact dermatitis include: thiuram rubber chemical accelerators, epoxy resin, and the antimicrobials methylchloroisothiazolinone/methylisothiazolinone, methyldibromo glutaronitrile, and formaldehyde. The highest risk of occupational contact dermatitis was found in occupations classified as 'other personal services workers', which includes hairdressers, nursing and other healthcare professionals, precision workers in metal and related materials, and blacksmiths, tool-makers and related trades workers. In the planning and implementation of measures aimed at preventing occupational contact dermatitis, the focus should be on the identified high-risk occupational groups and the most common occupational allergies. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Robust misinterpretation of confidence intervals.

    Science.gov (United States)

    Hoekstra, Rink; Morey, Richard D; Rouder, Jeffrey N; Wagenmakers, Eric-Jan

    2014-10-01

    Null hypothesis significance testing (NHST) is undoubtedly the most common inferential technique used to justify claims in the social sciences. However, even staunch defenders of NHST agree that its outcomes are often misinterpreted. Confidence intervals (CIs) have frequently been proposed as a more useful alternative to NHST, and their use is strongly encouraged in the APA Manual. Nevertheless, little is known about how researchers interpret CIs. In this study, 120 researchers and 442 students-all in the field of psychology-were asked to assess the truth value of six particular statements involving different interpretations of a CI. Although all six statements were false, both researchers and students endorsed, on average, more than three statements, indicating a gross misunderstanding of CIs. Self-declared experience with statistics was not related to researchers' performance, and, even more surprisingly, researchers hardly outperformed the students, even though the students had not received any education on statistical inference whatsoever. Our findings suggest that many researchers do not know the correct interpretation of a CI. The misunderstandings surrounding p-values and CIs are particularly unfortunate because they constitute the main tools by which psychologists draw conclusions from data.

  16. Colorimetric tests for diagnosis of filarial infection and vector surveillance using non-instrumented nucleic acid loop-mediated isothermal amplification (NINA-LAMP.

    Directory of Open Access Journals (Sweden)

    Catherine B Poole

    Full Text Available Accurate detection of filarial parasites in humans is essential for the implementation and evaluation of mass drug administration programs to control onchocerciasis and lymphatic filariasis. Determining the infection levels in vector populations is also important for assessing transmission, deciding when drug treatments may be terminated and for monitoring recrudescence. Immunological methods to detect infection in humans are available, however, cross-reactivity issues have been reported. Nucleic acid-based molecular assays offer high levels of specificity and sensitivity, and can be used to detect infection in both humans and vectors. In this study we developed loop-mediated isothermal amplification (LAMP tests to detect three different filarial DNAs in human and insect samples using pH sensitive dyes for enhanced visual detection of amplification. Furthermore, reactions were performed in a portable, non-instrumented nucleic acid amplification (NINA device that provides a stable heat source for LAMP. The efficacy of several strand displacing DNA polymerases were evaluated in combination with neutral red or phenol red dyes. Colorimetric NINA-LAMP assays targeting Brugia Hha I repeat, Onchocerca volvulus GST1a and Wuchereria bancrofti LDR each exhibit species-specificity and are also highly sensitive, detecting DNA equivalent to 1/10-1/5000th of one microfilaria. Reaction times varied depending on whether a single copy gene (70 minutes, O. volvulus or repetitive DNA (40 min, B. malayi and W. bancrofti was employed as a biomarker. The NINA heater can be used to detect multiple infections simultaneously. The accuracy, simplicity and versatility of the technology suggests that colorimetric NINA-LAMP assays are ideally suited for monitoring the success of filariasis control programs.

  17. Wallops Ship Surveillance System

    Science.gov (United States)

    Smith, Donna C.

    2011-01-01

    Approved as a Wallops control center backup system, the Wallops Ship Surveillance Software is a day-of-launch risk analysis tool for spaceport activities. The system calculates impact probabilities and displays ship locations relative to boundary lines. It enables rapid analysis of possible flight paths to preclude the need to cancel launches and allow execution of launches in a timely manner. Its design is based on low-cost, large-customer- base elements including personal computers, the Windows operating system, C/C++ object-oriented software, and network interfaces. In conformance with the NASA software safety standard, the system is designed to ensure that it does not falsely report a safe-for-launch condition. To improve the current ship surveillance method, the system is designed to prevent delay of launch under a safe-for-launch condition. A single workstation is designated the controller of the official ship information and the official risk analysis. Copies of this information are shared with other networked workstations. The program design is divided into five subsystems areas: 1. Communication Link -- threads that control the networking of workstations; 2. Contact List -- a thread that controls a list of protected item (ocean vessel) information; 3. Hazard List -- threads that control a list of hazardous item (debris) information and associated risk calculation information; 4. Display -- threads that control operator inputs and screen display outputs; and 5. Archive -- a thread that controls archive file read and write access. Currently, most of the hazard list thread and parts of other threads are being reused as part of a new ship surveillance system, under the SureTrak project.

  18. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  19. Self-surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    Gadgets and applications are increasingly being developed and used for tracking, quantifying, and documenting everyday life activities and especially health and fitness devices such as GPS-enabled sports watches are well-known and popular. However, self-surveillance practices involving networked...... pressure, fitness activities, sleep cycles, etc. can be broadcasted, e.g. as tweets on Twitter or status updates on Facebook. Such quantification practices with monitoring technologies become co-producing when individuals constitute themselves as subjects engaging in self-tracking, self-care, and self...

  20. GSFC Supplier Surveillance

    Science.gov (United States)

    Kelly, Michael P.

    2011-01-01

    Topics covered include: Develop Program/Project Quality Assurance Surveillance Plans The work activities performed by the developer and/or his suppliers are subject to evaluation and audit by government-designated representatives. CSO supports project by selecting on-site supplier representative s by one of several methods: (1) a Defense Contract Management Agency (DCMA) person via a Letter Of Delegation (LOD), (2) an independent assurance contractor (IAC) via a contract Audits, Assessments, and Assurance (A3) Contract Code 300 Mission Assurance Support Contract (MASC)

  1. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  2. Interval stability for complex systems

    Science.gov (United States)

    Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.

    2018-04-01

    Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.

  3. Semantic-based surveillance video retrieval.

    Science.gov (United States)

    Hu, Weiming; Xie, Dan; Fu, Zhouyu; Zeng, Wenrong; Maybank, Steve

    2007-04-01

    Visual surveillance produces large amounts of video data. Effective indexing and retrieval from surveillance video databases are very important. Although there are many ways to represent the content of video clips in current video retrieval algorithms, there still exists a semantic gap between users and retrieval systems. Visual surveillance systems supply a platform for investigating semantic-based video retrieval. In this paper, a semantic-based video retrieval framework for visual surveillance is proposed. A cluster-based tracking algorithm is developed to acquire motion trajectories. The trajectories are then clustered hierarchically using the spatial and temporal information, to learn activity models. A hierarchical structure of semantic indexing and retrieval of object activities, where each individual activity automatically inherits all the semantic descriptions of the activity model to which it belongs, is proposed for accessing video clips and individual objects at the semantic level. The proposed retrieval framework supports various queries including queries by keywords, multiple object queries, and queries by sketch. For multiple object queries, succession and simultaneity restrictions, together with depth and breadth first orders, are considered. For sketch-based queries, a method for matching trajectories drawn by users to spatial trajectories is proposed. The effectiveness and efficiency of our framework are tested in a crowded traffic scene.

  4. The study of the irradiation-induced embrittlement of reactor pressure vessels. Analysis of surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Nagai, Yasuyoshi; Toyama, Takeshi; Hasegawa, Masayuki

    2007-01-01

    The study of embrittlement of nuclear power reactor pressure vessels (RPVs) is of critical importance for the safety assessment in the nuclear industry. Some origins of embrittlement are attributed to fine Cu precipitates, matrix defects, grain boundary segregation of P and late blooming phase. This review article described nanostructural observation by three-dimensional atom probe (3DAP) and positron annihilation spectroscopy (PAS). The density and sizes of Cu-rich nanoprecipitates and grain boundary segregation are sensitively detected by 3DAP, and vacancies are probed by PAS. Element analysis around vacancies and fine microstructural Cu precipitates not containing vacancies are successfully observed by a coincidence doppler broadening method. The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of commercial nuclear reactor pressure vessel steel welds of Doel-2 in Belgium were revealed by combining 3DAP and PAS. In both medium (0.13 wt%) and high (0.30 wt%) Cu welds, the CRNPs were found to form readily at the very beginning of the reactor lifetime. On the other hand, small vacancy clusters start appearing after the initial Cu precipitates and accumulate steadily with increasing neutron dose. The CRNPs were also observed at very low dose rate of neutrons in the test specimen of Calder Hall Reactor of Japan Atomic Power Company. The significant enhancement of these Cu precipitates results in the embrittlement in practical RPVs. At very high dose of 2.2x10 18 n/cm 2 by JMTR, the Cu precipitates were scarcely observed, and the irradiation-induced embrittlement was primarily caused from vacancy-impurity complexes and dislocation loops. (author)

  5. The social dynamics of consent and refusal in HIV surveillance in rural South Africa.

    Science.gov (United States)

    Reynolds, Lindsey; Cousins, Thomas; Newell, Marie-Louise; Imrie, John

    2013-01-01

    In the context of low rates of participation in a prospective, population-based HIV surveillance programme, researchers at a surveillance site in rural KwaZulu-Natal, South Africa, conducted an operational study from January 2009 to February 2010, with the aim of improving participation rates, particularly in the provision of dried blood spots for the surveillance. Findings suggest, firstly, that consent to participation in the HIV surveillance is informed by the dynamics of relationality in the HIV surveillance "consent encounter." Secondly, it emerged that both fieldworkers and participants found it difficult to differentiate between HIV surveillance and HIV testing in the surveillance procedure, and tended to understand and explain giving blood under the aegis of the surveillance as an HIV test. The conflation of surveillance and testing, we argue, is not merely a semantic confusion, but reveals an important tension inherent to global health research between individual risks and benefits and collective good, or between private morality and public good. Because of these structural tensions, we suggest, the HIV surveillance consent encounter activates multiple gift economies in the collection of blood samples. Thinking beyond the complex ethical dimensions provoked by new forms of long-term surveillance and health research, we therefore suggest that deepening relations between scientists, fieldworkers, and study participants in locality deserve more careful methodological consideration and descriptive attention. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Use of multiple objective evolutionary algorithms in optimizing surveillance requirements

    International Nuclear Information System (INIS)

    Martorell, S.; Carlos, S.; Villanueva, J.F.; Sanchez, A.I; Galvan, B.; Salazar, D.; Cepin, M.

    2006-01-01

    This paper presents the development and application of a double-loop Multiple Objective Evolutionary Algorithm that uses a Multiple Objective Genetic Algorithm to perform the simultaneous optimization of periodic Test Intervals (TI) and Test Planning (TP). It takes into account the time-dependent effect of TP performed on stand-by safety-related equipment. TI and TP are part of the Surveillance Requirements within Technical Specifications at Nuclear Power Plants. It addresses the problem of multi-objective optimization in the space of dependable variables, i.e. TI and TP, using a novel flexible structure of the optimization algorithm. Lessons learnt from the cases of application of the methodology to optimize TI and TP for the High-Pressure Injection System are given. The results show that the double-loop Multiple Objective Evolutionary Algorithm is able to find the Pareto set of solutions that represents a surface of non-dominated solutions that satisfy all the constraints imposed on the objective functions and decision variables. Decision makers can adopt then the best solution found depending on their particular preference, e.g. minimum cost, minimum unavailability

  7. Sonoma Persistent Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, D M

    2006-03-24

    Sonoma offers the first cost-effective, broad-area, high-resolution, real-time motion imagery system for surveillance applications. Sonoma is unique in its ability to provide continuous, real-time video imagery of an area the size of a small city with resolutions sufficient to track 8,000 moving objects in the field of view. At higher resolutions and over smaller areas, Sonoma can even track the movement of individual people. The visual impact of the data available from Sonoma is already causing a paradigm shift in the architecture and operation of other surveillance systems. Sonoma is expected to cost just one-tenth the price of comparably sized sensor systems. Cameras mounted on an airborne platform constantly monitor an area, feeding data to the ground for real-time analysis. Sonoma was designed to provide real-time data for actionable intelligence in situations such as monitoring traffic, special events, border security, and harbors. If a Sonoma system had been available in the aftermath of the Katrina and Rita hurricanes, emergency responders would have had real-time information on roads, water levels, and traffic conditions, perhaps saving many lives.

  8. Advanced neutron source materials surveillance program

    International Nuclear Information System (INIS)

    Heavilin, S.M.

    1995-01-01

    The Advanced Neutron Source (ANS) will be composed of several different materials, one of which is 6061-T6 aluminum. Among other components, the reflector vessel and the core pressure boundary tube (CPBT), are to be made of 6061-T6 aluminum. These components will be subjected to high thermal neutron fluences and will require a surveillance program to monitor the strength and fracture toughness of the 6061-T6 aluminum over their lifetimes. The purpose of this paper is to explain the steps that were taken in the summer of 1994 toward developing the surveillance program. The first goal was to decide upon standard specimens to use in the fracture toughness and tensile testing. Second, facilities had to be chosen for specimens representing the CPBT and the reflector vessel base, weld, and heat-affected-zone (HAZ) metals. Third, a timetable had to be defined to determine when to remove the specimens for testing

  9. Vascular access surveillance: case study of a false paradigm.

    Science.gov (United States)

    Paulson, William D; Moist, Louise; Lok, Charmaine E

    2013-01-01

    The hemodialysis vascular access surveillance controversy provides a case study of how enthusiasm for a new test or treatment can lead to adoption of a false paradigm. Paradigms are the beliefs and assumptions shared by those in a field of knowledge, and are commonly included in clinical practice guidelines. The guidelines of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommend that arteriovenous vascular accesses undergo routine surveillance for detection and correction of stenosis. This recommendation is based on the paradigm that surveillance of access blood flow or dialysis venous pressure combined with correction of stenosis improves access outcomes. However, the quality of evidence that supports this paradigm has been widely criticized. We tested the validity of the surveillance paradigm by applying World Health Organization (WHO) criteria for evaluating screening tests to a literature review of published vascular access studies. These criteria include four components: undesired condition, screening test, intervention, and desired outcome. The WHO criteria show that surveillance as currently practiced fails all four components and provides little or no significant benefit, suggesting that surveillance is a false paradigm. Once a paradigm is established, however, challenges to its validity are usually resisted even as new evidence indicates the paradigm is not valid. Thus, it is paramount to apply rigorous criteria when developing guidelines. Regulators may help promote needed changes in paradigms when cost and safety considerations coincide. © 2013 Wiley Periodicals, Inc.

  10. Mapping of the US Domestic Influenza Virologic Surveillance Landscape.

    Science.gov (United States)

    Jester, Barbara; Schwerzmann, Joy; Mustaquim, Desiree; Aden, Tricia; Brammer, Lynnette; Humes, Rosemary; Shult, Pete; Shahangian, Shahram; Gubareva, Larisa; Xu, Xiyan; Miller, Joseph; Jernigan, Daniel

    2018-07-17

    Influenza virologic surveillance is critical each season for tracking influenza circulation, following trends in antiviral drug resistance, detecting novel influenza infections in humans, and selecting viruses for use in annual seasonal vaccine production. We developed a framework and process map for characterizing the landscape of US influenza virologic surveillance into 5 tiers of influenza testing: outpatient settings (tier 1), inpatient settings and commercial laboratories (tier 2), state public health laboratories (tier 3), National Influenza Reference Center laboratories (tier 4), and Centers for Disease Control and Prevention laboratories (tier 5). During the 2015-16 season, the numbers of influenza tests directly contributing to virologic surveillance were 804,000 in tiers 1 and 2; 78,000 in tier 3; 2,800 in tier 4; and 3,400 in tier 5. With the release of the 2017 US Pandemic Influenza Plan, the proposed framework will support public health officials in modeling, surveillance, and pandemic planning and response.

  11. Surveillance of healthcare-associated infection in hospitalised South African children: Which method performs best?

    Directory of Open Access Journals (Sweden)

    A Dramowski

    2017-01-01

    Full Text Available Background. In 2012, the South African (SA National Department of Health mandated surveillance of healthcare-associated infection (HAI, but made no recommendations of appropriate surveillance methods. Methods. Prospective clinical HAI surveillance (the reference method was conducted at Tygerberg Children’s Hospital, Cape Town, from 1 May to 31 October 2015. Performance of three surveillance methods (point prevalence surveys (PPSs, laboratory surveillance and tracking of antimicrobial prescriptions was compared with the reference method using surveillance evaluation guidelines. Factors associated with failure to detect HAI were identified by logistic regression analysis. Results. The reference method detected 417 HAIs among 1 347 paediatric hospitalisations (HAI incidence of 31/1000 patient days; 95% confidence interval (CI 28.2 - 34.2. Surveillance methods had variable sensitivity (S and positive predictive value (PPV: PPS S = 24.9% (95% CI 21 - 29.3, PPV = 100%; laboratory surveillance S = 48.4% (95% CI 43.7 - 53.2, PPV = 55.2% (95% CI 50.1 - 60.2; and antimicrobial prescriptions S = 66.4% (95% CI 61.8 - 70.8%, PPV = 88.5% (95% CI 84.5 - 91.6. Combined laboratory-antimicrobial surveillance achieved superior HAI detection (S = 84.7% (95% CI 80.9 - 87.8%, PPV = 97% (95% CI 94.6 - 98.4%. Factors associated with failure to detect HAI included patient transfer (odds ratio (OR 2.0, single HAI event (OR 2.8, age category 1 - 5 years (OR 2.1 and hospitalisation in a general ward (OR 2.3. Conclusions. Repeated PPSs, laboratory surveillance and/or antimicrobial prescription tracking are feasible HAI surveillance methods for low-resource settings. Combined laboratory-antimicrobial surveillance achieved the best sensitivity and PPV. SA paediatric healthcare facilities should individualise HAI surveillance, selecting a method suited to available resources and practice context.

  12. 2012 Sexually Transmitted Diseases Surveillance

    Science.gov (United States)

    ... Data Appendix Tables A1 - A4 STD Surveillance Case Definitions Contributors Related Links STD Home STD Data & Statistics NCHHSTP Atlas Interactive STD Data - 1996-2013 STD Health Equity HIV/AIDS Surveillance & Statistics Follow STD STD on Twitter STD on Facebook File Formats Help: How do I view different ...

  13. Surveillance robot for nuclear power plants

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Satterlee, P.E. Jr.

    1985-01-01

    A demonstration project to determine the feasibility and cost-effectiveness of mobile surveillance robots in nuclear power plants is being conducted by the Remote Technology Corporation (REMOTEC) for the US Nuclear Regulatory Commission. Phase I of the project was completed in March 1984 and included a survey of currently used robotic equipment and the development of a robotics application methodology. Three Tennessee Valley Authority plants were analyzed to identify specific plant areas with a high potential for surveillance robotics. Based on these results, a number of robotic system applications were prepared and evaluated for cost-effectiveness. The system with the highest potential, a mobile surveillance robot, was selected for fabrication and in-plant demonstration testing in a phase II effort. The design, fabrication, and assembly of SURBOT has been completed and cold testing is in process. It will be installed at the Browns Ferry Nuclear Plant early in 1986 for demonstration testing. Current projections are that SURBOT can be used in approx.40 rooms within the auxiliary building and will have annual savings of over 100 person-rem exposure, 1000 sets of C-zone clothing, and 1000 person-hours of labor

  14. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    An effective public safety sensor system for heavily-populated applications requires sophisticated and geographically-distributed infrastructures, centralized supervision, and deployment of large-scale security and surveillance networks. Artificial intelligence in sensor systems is a critical design to raise awareness levels, improve the performance of the system and adapt to a changing scenario and environment. In this paper, a highly-distributed, fault-tolerant, and energy-efficient Smart Sensing Surveillance System (S4) is presented to efficiently provide a 24/7 and all weather security operation in crowded environments or restricted areas. Technically, the S4 consists of a number of distributed sensor nodes integrated with specific passive sensors to rapidly collect, process, and disseminate heterogeneous sensor data from near omni-directions. These distributed sensor nodes can cooperatively work to send immediate security information when new objects appear. When the new objects are detected, the S4 will smartly select the available node with a Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR camera to track the objects and capture associated imagery. The S4 provides applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. Other imaging processes can be updated to meet specific requirements and operations. In the S4, all the sensor nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology. This UWB RF technology can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The Service Oriented Architecture of S4 enables remote applications to interact with the S4

  15. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    Unattended ground sensor (UGS) networks have been widely used in remote battlefield and other tactical applications over the last few decades due to the advances of the digital signal processing. The UGS network can be applied in a variety of areas including border surveillance, special force operations, perimeter and building protection, target acquisition, situational awareness, and force protection. In this paper, a highly-distributed, fault-tolerant, and energyefficient Smart Sensing Surveillance System (S4) is presented to efficiently provide 24/7 and all weather security operation in a situation management environment. The S4 is composed of a number of distributed nodes to collect, process, and disseminate heterogeneous sensor data. Nearly all S4 nodes have passive sensors to provide rapid omnidirectional detection. In addition, Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR cameras are integrated to selected nodes to track the objects and capture associated imagery. These S4 camera-connected nodes will provide applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. In the S4, all the nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology, which can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The S4 utilizes a Service Oriented Architecture such that remote applications can interact with the S4 network and use the specific presentation methods. The S4 capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded

  16. A generic rabies risk assessment tool to support surveillance.

    Science.gov (United States)

    Ward, Michael P; Hernández-Jover, Marta

    2015-06-01

    The continued spread of rabies in Indonesia poses a risk to human and animal populations in the remaining free islands, as well as the neighbouring rabies-free countries of Timor Leste, Papua New Guinea and Australia. Here we describe the development of a generic risk assessment tool which can be used to rapidly determine the vulnerability of rabies-free islands, so that scarce resources can be targeted to surveillance activities and the sensitivity of surveillance systems increased. The tool was developed by integrating information on the historical spread of rabies, anthropological studies, and the opinions of local animal health experts. The resulting tool is based on eight critical parameters that can be estimated from the literature, expert opinion, observational studies and information generated from routine surveillance. In the case study presented, results generated by this tool were most sensitive to the probability that dogs are present on private and fishing boats and it was predicted that rabies-infection (one infected case) might occur in a rabies-free island (upper 95% prediction interval) with a volume of 1000 boats movements. With 25,000 boat movements, the median of the probability distribution would be equal to one infected case, with an upper 95% prediction interval of six infected cases. This tool could also be used at the national-level to guide control and eradication plans. An initial recommendation from this study is to develop a surveillance programme to determine the likelihood that boats transport dogs, for example by port surveillance or regularly conducted surveys of fisherman and passenger ferries. However, the illegal nature of dog transportation from rabies-infected to rabies-free islands is a challenge for developing such surveillance. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Surveillance theory and its implications for law

    NARCIS (Netherlands)

    Timan, Tjerk; Galic, Masa; Koops, Bert-Jaap; Brownsword, Roger; Scotford, Eloise; Yeung, Karen

    2017-01-01

    This chapter provides an overview of key surveillance theories and their implications for law and regulation. It presents three stages of theories that characterise changes in thinking about surveillance in society and the disciplining, controlling, and entertaining functions of surveillance.

  18. Reporting and Surveillance for Norovirus Outbreaks

    Science.gov (United States)

    ... Vaccine Surveillance Network (NVSN) Foodborne Diseases Active Surveillance Network (FoodNet) National Outbreak Reporting System (NORS) Estimates of Foodborne Illness in the United States CDC's Vessel Sanitation Program CDC Feature: Surveillance for Norovirus Outbreaks Top ...

  19. Suboptimal processor for anomaly detection for system surveillance and diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ciftcioglu, Oe.; Hoogenboom, J.E.; Dam, H. van

    1989-06-01

    Anomaly detection for nuclear reactor surveillance and diagnosis is described. The residual noise obtained as a result of autoregressive (AR) modelling is essential to obtain high sensitivity for anomaly detection. By means of the method of hypothesis testing a suboptimal anomaly detection processor is devised for system surveillance and diagnosis. Experiments are carried out to investigate the performance of the processor, which is in particular of interest for on-line and real-time applications.

  20. VNIIEF NMPC and A Maintenance Management Conference video surveillance

    International Nuclear Information System (INIS)

    Malone, T.

    1997-08-01

    This paper is part of ongoing Nuclear Materials Protection, Control and Accountability (NMPC and A) work with the All Russian Scientific Research Institute of Experimental Physics (VNIIEF), Sarov, Russia. The material presented in the paper is to provide guidance for the preparation of maintenance management for NMPC and A video assessment and surveillance subsystems being installed at VNIIEF. This paper discusses maintenance philosophies, performance testing, equipment inspection/setup, and record keeping for a video assessment and surveillance subsystem

  1. Total process surveillance: (TOPS)

    International Nuclear Information System (INIS)

    Millar, J.H.P.

    1992-01-01

    A Total Process Surveillance system is under development which can provide, in real-time, additional process information from a limited number of raw measurement signals. This is achieved by using a robust model based observer to generate estimates of the process' internal states. The observer utilises the analytical reduncancy among a diverse range of transducers and can thus accommodate off-normal conditions which lead to transducer loss or damage. The modular hierarchical structure of the system enables the maximum amount of information to be assimilated from the available instrument signals no matter how diverse. This structure also constitutes a data reduction path thus reducing operator cognitive overload from a large number of varying, and possibly contradictory, raw plant signals. (orig.)

  2. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-02-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  3. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-03-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  4. Secure surveillance videotapes

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.; Olsen, R.; Chitumbo, K.; Pepper, S.

    1995-01-01

    With assistance from the US Program for Technical Assistance to IAEA Safeguards (POTAS), Aquila Technologies Group developed the Tamper-Resistant Analog Media (TRAM-1000) system to provide standard VHS surveillance video tapes with an enhanced tamper-indicating capability. This project represents further implementation of the partnership approach in facilities including light water reactors with MOX facilities. These facilities use Uniplex Digiquad system video tapes. The partnership approach ensures that one organization can exchange the tapes in a machine without the presence of the other, without losing continuity of information. The TRAM-1000 system development project was accomplished in two stages. In the first stage of the project, the original system delivered to the IAEA, consists of three parts: (1) the tamper detection unit, (2) a specially augmented VHS video tape, and (3) an HP-95 reader. The tamper detection unit houses a VACOSS active fiber-optic seal and an electronic identification tag (E-TAG) reader. In the second stage of the project, the original TRAM-1000 was modified to its current design based on agency input. After delivery of the original TRAM-1000 system to the IAEA, it was reviewed by inspectors. The inspectors felt that the initial system's tape storage/transport method could be simplified. Rather than threading the fiber through the tape spindles, the inspectors suggested that the tape be placed in a bag capable of being sealed. Also, a more flexible fiber-optic cable was recommended. As a result of these suggestions, Aquila developed a tamper-proof bag specifically for holding a surveillance video tape and sealable with a VACOSS fiber optical seal

  5. Surveillance of Tuberculosis in Taipei: The Influence of Nontuberculous Mycobacteria.

    Directory of Open Access Journals (Sweden)

    Chen-Yuan Chiang

    Full Text Available Notification of tuberculosis (TB but not nontuberculous mycobacteria (NTM is mandatory in Taiwan. Partly due to the strict regulation on TB notification, several patients infected with NTM were notified as TB cases. Notification of patients infected with NTM as TB cases can trigger public health actions and impose additional burdens on the public health system. We conducted a study to assess the influence of NTM infection on surveillance of TB in Taipei.The study population included all individuals with a positive culture for Mycobacterium who were citizens of Taipei City and notified as TB cases in the calendar years 2007-2010. Of the 4216 notified culture-positive tuberculosis (TB cases, 894 (21.2% were infected with NTM. The average annual reported case rate of infection with NTM was 8.6 (95% confidence interval 7.7-9.4 per 100,000 people. The reported case rate of NTM increased with age in both males and females. The proportion of reported TB cases infected with NTM was significantly higher in females than in males (27.6% vs 17.8%, adjusted OR (adjOR 1.93, 95% confidence interval (CI 1.63-2.28; in smear-positive than in smear-negative (23.1% vs 19.2%, adjOR 1.26, 95% CI 1.08-1.47; and in previously treated cases than in new cases (35.7% vs 19.1%, adjOR 2.30, 95% CI 1.88-2.82. The most frequent species was M. avium complex (32.4%, followed by M. chelonae complex (17.6%, M. fortuitum complex (17.0% and M. kansasii (9.8%. Of the 890 notified NTM cases assessed, 703 (79.0% were treated with anti-TB drugs, and 730 (82.0% were de-notified.The influence of NTM on surveillance of TB in Taipei was substantial. Health authorities should take action to ensure that nucleic acid amplification tests are performed in all smear-positive cases in a timely manner to reduce the misdiagnosis of patients infected with NTM as TB cases.

  6. Surveillance of Tuberculosis in Taipei: The Influence of Nontuberculous Mycobacteria.

    Science.gov (United States)

    Chiang, Chen-Yuan; Yu, Ming-Chih; Yang, Shiang-Lin; Yen, Muh-Yong; Bai, Kuan-Jen

    2015-01-01

    Notification of tuberculosis (TB) but not nontuberculous mycobacteria (NTM) is mandatory in Taiwan. Partly due to the strict regulation on TB notification, several patients infected with NTM were notified as TB cases. Notification of patients infected with NTM as TB cases can trigger public health actions and impose additional burdens on the public health system. We conducted a study to assess the influence of NTM infection on surveillance of TB in Taipei. The study population included all individuals with a positive culture for Mycobacterium who were citizens of Taipei City and notified as TB cases in the calendar years 2007-2010. Of the 4216 notified culture-positive tuberculosis (TB) cases, 894 (21.2%) were infected with NTM. The average annual reported case rate of infection with NTM was 8.6 (95% confidence interval 7.7-9.4) per 100,000 people. The reported case rate of NTM increased with age in both males and females. The proportion of reported TB cases infected with NTM was significantly higher in females than in males (27.6% vs 17.8%, adjusted OR (adjOR) 1.93, 95% confidence interval (CI) 1.63-2.28); in smear-positive than in smear-negative (23.1% vs 19.2%, adjOR 1.26, 95% CI 1.08-1.47); and in previously treated cases than in new cases (35.7% vs 19.1%, adjOR 2.30, 95% CI 1.88-2.82). The most frequent species was M. avium complex (32.4%), followed by M. chelonae complex (17.6%), M. fortuitum complex (17.0%) and M. kansasii (9.8%). Of the 890 notified NTM cases assessed, 703 (79.0%) were treated with anti-TB drugs, and 730 (82.0%) were de-notified. The influence of NTM on surveillance of TB in Taipei was substantial. Health authorities should take action to ensure that nucleic acid amplification tests are performed in all smear-positive cases in a timely manner to reduce the misdiagnosis of patients infected with NTM as TB cases.

  7. Generalized Confidence Intervals and Fiducial Intervals for Some Epidemiological Measures

    Directory of Open Access Journals (Sweden)

    Ionut Bebu

    2016-06-01

    Full Text Available For binary outcome data from epidemiological studies, this article investigates the interval estimation of several measures of interest in the absence or presence of categorical covariates. When covariates are present, the logistic regression model as well as the log-binomial model are investigated. The measures considered include the common odds ratio (OR from several studies, the number needed to treat (NNT, and the prevalence ratio. For each parameter, confidence intervals are constructed using the concepts of generalized pivotal quantities and fiducial quantities. Numerical results show that the confidence intervals so obtained exhibit satisfactory performance in terms of maintaining the coverage probabilities even when the sample sizes are not large. An appealing feature of the proposed solutions is that they are not based on maximization of the likelihood, and hence are free from convergence issues associated with the numerical calculation of the maximum likelihood estimators, especially in the context of the log-binomial model. The results are illustrated with a number of examples. The overall conclusion is that the proposed methodologies based on generalized pivotal quantities and fiducial quantities provide an accurate and unified approach for the interval estimation of the various epidemiological measures in the context of binary outcome data with or without covariates.

  8. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  9. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal of this paper is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  10. Haemostatic reference intervals in pregnancy

    DEFF Research Database (Denmark)

    Szecsi, Pal Bela; Jørgensen, Maja; Klajnbard, Anna

    2010-01-01

    largely unchanged during pregnancy, delivery, and postpartum and were within non-pregnant reference intervals. However, levels of fibrinogen, D-dimer, and coagulation factors VII, VIII, and IX increased markedly. Protein S activity decreased substantially, while free protein S decreased slightly and total......Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age......-20, 21-28, 29-34, 35-42, at active labor, and on postpartum days 1 and 2. Reference intervals for each gestational period using only the uncomplicated pregnancies were calculated in all 391 women for activated partial thromboplastin time (aPTT), fibrinogen, fibrin D-dimer, antithrombin, free protein S...

  11. Malaria Surveillance - United States, 2015.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M; Tan, Kathrine R

    2018-05-04

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles species mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to provide information on its occurrence (e.g., temporal, geographic, and demographic), guide prevention and treatment recommendations for travelers and patients, and facilitate transmission control measures if locally acquired cases are identified. This report summarizes confirmed malaria cases in persons with onset of illness in 2015 and summarizes trends in previous years. Malaria cases diagnosed by blood film microscopy, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff members. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System (NMSS), the National Notifiable Diseases Surveillance System (NNDSS), or direct CDC consultations. CDC reference laboratories provide diagnostic assistance and conduct antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. This report summarizes data from the integration of all NMSS and NNDSS cases, CDC reference laboratory reports, and CDC clinical consultations. CDC received reports of 1,517 confirmed malaria cases, including one congenital case, with an onset of symptoms in 2015 among persons who received their diagnoses in the United States. Although the number of

  12. Inverse Interval Matrix: A Survey

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří; Farhadsefat, R.

    2011-01-01

    Roč. 22, - (2011), s. 704-719 E-ISSN 1081-3810 R&D Projects: GA ČR GA201/09/1957; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : interval matrix * inverse interval matrix * NP-hardness * enclosure * unit midpoint * inverse sign stability * nonnegative invertibility * absolute value equation * algorithm Subject RIV: BA - General Mathematics Impact factor: 0.808, year: 2010 http://www.math.technion.ac.il/iic/ ela / ela -articles/articles/vol22_pp704-719.pdf

  13. A New Molecular Surveillance System for Leishmaniasis

    Science.gov (United States)

    Pandey, Kishor; Pandey, Basu Dev; Mallik, Arun Kumar; Acharya, Jyoti; Kato, Kentaro; Kaneko, Osamu; Ferreira, Pedro Eduardo

    2014-01-01

    Abstract. Presently, global efforts are being made to control and eradicate the deadliest tropical diseases through the improvement of adequate interventions. A critical point for programs to succeed is the prompt and accurate diagnosis in endemic regions. Rapid diagnostic tests (RDTs) are being massively deployed and used to improve diagnosis in tropical countries. In the present report, we evaluated the hypothesis of, after use for diagnosis, the reuse of the Leishmania RDT kit as a DNA source, which can be used downstream as a molecular surveillance and/or quality control tool. As a proof of principle, a polymerase chain reaction-based method was used to detect Leishmania spp. minicircle kinetoplast DNA from leishmaniasis RDT kits. Our results show that Leishmania spp. DNA can be extracted from used RDTs and may constitute an important, reliable, and affordable tool to assist in future leishmaniasis molecular surveillance methods. PMID:24752687

  14. Surveyor mobile surveillance system for hazardous environments

    International Nuclear Information System (INIS)

    Silverman, E.B.; Simmons, R.K.; Kniazewycz, B.G.; Darvish, A.R.; Irving, T.L.

    1987-01-01

    A successful program was recently conducted to test and evaluate a commercial-ready, wireless, remotely operated surveillance system for use in nuclear power plants. This evaluation of the Surveyor mobile surveillance system took place at Niagara Mohawk Power Corporation's Nine Mile Point Nuclear Power Station. The remotely operated vehicle measures radiation, temperature and relative humidity and provides optical inspection capability. The vehicle is readily maneuvered in 36-inch wide passageways and labyrinth entries and can climb stairs, negotiating 180-degree turns on stair landings. The system consists of a supervisory control station and a rugged, remotely-operated, battery-powered vehicle. The surveyor system is specifically designed to decrease personnel radiation exposure by supplementing the functions of an auxiliary operator or wealth physics technician to perform periodic component inspections inside particular areas within a nuclear power plant

  15. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a laser system and have used it with a simulated BWR assembly. The reflected signal from the zircaloy rods depends on the position of the assembly, but in all cases is easily discernable from the reference scan of background with no assembly

  16. Epidemiological modelling for the assessment of bovine tuberculosis surveillance in the dairy farm network in Emilia-Romagna (Italy

    Directory of Open Access Journals (Sweden)

    Gianluigi Rossi

    2015-06-01

    Our analysis showed that slaughterhouse inspection is the most effective surveillance component in reducing the time for disease detection, while routine surveillance in reducing the number of multi-farms epidemics. On the other hand, testing exchanged cattle improved the performance of the surveillance system only marginally.

  17. Performance of Syphilis Sentinel Surveillance in the context of endemic Treponematoses: experience from Ghana.

    Science.gov (United States)

    Dassah, Edward Tieru; Adu-Sarkodie, Yaw; Mayaud, Philippe

    2016-12-09

    Use of treponemal tests to screen for syphilis (caused by Treponema pallidum pallidum) poses challenges with infection status classification, especially in settings where other treponemal infections are endemic. This study aimed to determine the validity of the syphilis surveillance testing strategy implemented since 2004 using two treponemal tests, and estimate the seroprevalence of active syphilis infection in Ghana where yaws (caused by Treponema pallidum pertenue) is endemic. We retested sera from the 2007 HIV sentinel survey (HSS) using a traditional algorithm, quantitative rapid plasma reagin test followed by qualitative Treponema pallidum haemagglutination assay. The adjusted seroprevalence of active syphilis was calculated by applying the proportions of active syphilis within identified categories of HSS samples during the retesting, to the entire population of HSS samples. The 95% confidence intervals (CIs) were calculated for each proportion, and the t-test was used to assess differences in proportions. Of 2,214 samples that were retested, 203 (9.2%) had active syphilis infection, 21 (0.9%) were biological false reactions, 640 (28.9%) were past or treated syphilis infections, and 1,350 (61%) were uninfected. The current syphilis testing strategy overestimated the seroprevalence of active syphilis infection by a third (HSS versus traditional algorithm: 6.0% (95% CI: 5.6-6.3) vs. 4.5% (95% CI: 4.2-4.8); p syphilis infection. More than half (51.9%) of HSS syphilis positive cases were actually past/treated treponemal infections, possibly previous exposure to yaws. There is an urgent need to review the current syphilis sentinel surveillance testing strategy in Ghana in the context of concurrent endemic treponematoses, to better inform policy.

  18. Dynamic Properties of QT Intervals

    Czech Academy of Sciences Publication Activity Database

    Halámek, Josef; Jurák, Pavel; Vondra, Vlastimil; Lipoldová, J.; Leinveber, Pavel; Plachý, M.; Fráňa, P.; Kára, T.

    2009-01-01

    Roč. 36, - (2009), s. 517-520 ISSN 0276-6574 R&D Projects: GA ČR GA102/08/1129; GA MŠk ME09050 Institutional research plan: CEZ:AV0Z20650511 Keywords : QT Intervals * arrhythmia diagnosis Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://cinc.mit.edu/archives/2009/pdf/0517.pdf

  19. Interval matrices: Regularity generates singularity

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří; Shary, S.P.

    2018-01-01

    Roč. 540, 1 March (2018), s. 149-159 ISSN 0024-3795 Institutional support: RVO:67985807 Keywords : interval matrix * regularity * singularity * P-matrix * absolute value equation * diagonally singilarizable matrix Subject RIV: BA - General Mathematics Impact factor: 0.973, year: 2016

  20. Chaotic dynamics from interspike intervals

    DEFF Research Database (Denmark)

    Pavlov, A N; Sosnovtseva, Olga; Mosekilde, Erik

    2001-01-01

    Considering two different mathematical models describing chaotic spiking phenomena, namely, an integrate-and-fire and a threshold-crossing model, we discuss the problem of extracting dynamics from interspike intervals (ISIs) and show that the possibilities of computing the largest Lyapunov expone...

  1. The critical role of acute flaccid paralysis surveillance in the Global Polio Eradication Initiative.

    Science.gov (United States)

    Tangermann, Rudolf H; Lamoureux, Christine; Tallis, Graham; Goel, Ajay

    2017-05-01

    Acute flaccid paralysis (AFP) surveillance is a key strategy used by the Global Polio Eradication Initiative (GPEI) to measure progress towards reaching the global eradication goal. Supported by a global polio laboratory network, AFP surveillance is conducted in 179 of 194 WHO member states. Active surveillance visits to priority health facilities are used to assure all children polio laboratories. The quality of AFP surveillance is regularly monitored with standardized surveillance quality indicators. In highest risk countries and areas, the sensitivity of AFP surveillance is enhanced by environmental surveillance (testing of sewage samples). Genetic sequencing of detected poliovirus isolates yields programmatically important information on polio transmission pathways. AFP surveillance is one of the most valuable assets of the GPEI, with the potential to serve as a platform to build integrated disease surveillance systems. Continued support to maintain AFP surveillance systems will be essential, to reliably monitor the completion of global polio eradication, and to assure that a key resource for building surveillance capacity is transitioned post-eradication to support other health priorities. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Active surveillance for localized prostate cancer

    DEFF Research Database (Denmark)

    Thomsen, Frederik B; Berg, Kasper D; Røder, M Andreas

    2015-01-01

    and costs of AS in patients with localized PCa. MATERIALS AND METHODS: In total, 317 PCa patients were followed in a prospective, single-arm AS cohort. The primary outcomes were number of patient contacts, prostate-specific antigen (PSA) tests, biopsies, hospital admissions due to biopsy complications......OBJECTIVE: Evidence supports active surveillance (AS) as a means to reduce overtreatment of low-risk prostate cancer (PCa). The consequences of close and long-standing follow-up with regard to outpatient visits, tests and repeated biopsies are widely unknown. This study investigated the trajectory...

  3. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico; Definicion de la longitud minima de inserto en la reconstitucion de probetas Charpy para vigilancia y extension de vida de vasijas en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M., E-mail: jesus.romero@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm{sup 3} in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  4. Risk of metachronous neoplasia on surveillance colonoscopy in young patients with colorectal neoplasia.

    Science.gov (United States)

    Kim, Hyun Gun; Cho, Young-Seok; Cha, Jae Myung; Shin, Jeong Eun; Kim, Kyeong Ok; Yang, Hyo-Joon; Koo, Hoon Sup; Joo, Young-Eun; Boo, Sun-Jin

    2018-03-01

    Few prior reports exist that address the appropriate colonoscopy surveillance interval for individuals  .1). In the baseline low-risk adenoma group (n = 1869), the 5-year risk of metachronous advanced neoplasia was 4.9% in the younger patients on screening colonoscopy and 5.1% in the older patients (P > .1). Similarly, in the baseline no neoplasia group (n = 7013), the 5-year risk of metachronous advanced neoplasia was 4.1% in the younger patients on screening colonoscopy and 5.6% in the older patients (P > .1). Considering the similar risk of metachronous advanced neoplasia in younger and older individuals, we suggest a 3-year surveillance interval for high-risk adenoma and a 5-year surveillance interval for low-risk adenoma in young individuals without a strong family history. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to identify episodes of local transmission and to guide prevention recommendations for travelers. This report summarizes cases in persons with onset of illness in 2014 and trends during previous years. Malaria cases diagnosed by blood film, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System, National Notifiable Diseases Surveillance System, or direct CDC consultations. CDC conducts antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. Data from these reporting systems serve as the basis for this report. CDC received reports of 1,724 confirmed malaria cases, including one congenital case and two cryptic cases, with onset of symptoms in 2014 among persons in the United States. The number of confirmed cases in 2014 is consistent with the number of confirmed cases reported in 2013 (n = 1,741; this number has been updated from a previous publication to account for delayed reporting for persons with symptom onset occurring in late 2013). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 66.1%, 13.3%, 5.2%, and 2.7% of cases, respectively

  6. Evaluation of Healing Intervals of Incisional Skin Wounds of Goats ...

    African Journals Online (AJOL)

    The aim of this study was to compare the healing intervals among simple interrupted (SI), ford interlocking (FI) and subcuticular (SC) suture patterns in goats. We hypothesized that these common suture patterns used for closure of incisional skin wounds may have effect on the healing interval. To test this hypothesis, two ...

  7. T(peak)T(end) interval in long QT syndrome

    DEFF Research Database (Denmark)

    Kanters, Jørgen Kim; Haarmark, Christian; Vedel-Larsen, Esben

    2008-01-01

    BACKGROUND: The T(peak)T(end) (T(p)T(e)) interval is believed to reflect the transmural dispersion of repolarization. Accordingly, it should be a risk factor in long QT syndrome (LQTS). The aim of the study was to determine the effect of genotype on T(p)T(e) interval and test whether it was relat...

  8. Radioisotopic Thermoelectric Generator (RTG) Surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Mulford, Roberta Nancy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-29

    This lecture discusses stockpile stewardship efforts and the role surveillance plays in the process. Performance of the RTGs is described, and the question of the absence of anticipated He is addressed.

  9. Surveillance of nuclear power reactors

    International Nuclear Information System (INIS)

    Marini, J.

    1983-01-01

    Surveillance of nuclear power reactors is now a necessity imposed by such regulatory documents as USNRC Regulatory Guide 1.133. In addition to regulatory requirements, however, nuclear reactor surveillance offers plant operators significant economic advantages insofar as a single day's outage is very costly. The economic worth of a reactor surveillance system can be stated in terms of the improved plant availability provided through its capability to detect incidents before they occur and cause serious damage. Furthermore, the TMI accident has demonstrated the need for monitoring certain components to provide operators with clear information on their functional status. In response to the above considerations, Framatome has developed a line of products which includes: pressure vessel leakage detection systems, loose part detection systems, component vibration monitoring systems, and, crack detection and monitoring systems. Some of the surveillance systems developed by Framatome are described in this paper

  10. Youth Risk Behavior Surveillance System

    Science.gov (United States)

    ... Youth Risk Behavior Surveillance System (YRBSS) monitors six types of health-risk behaviors that contribute to the leading causes of death and disability among youth and adults, including— Behaviors that contribute ...

  11. Health surveillance - myth and reality

    International Nuclear Information System (INIS)

    Sharp, C.

    1998-01-01

    This paper discusses the principles, health benefit and cost-effectiveness of health surveillance in the occupational setting, which apply to exposure to ionising radiations in the same manner as to other hazards in the workplace. It highlights the techniques for undertaking health surveillance, discusses their relative advantages and disadvantages and illustrates these in relation to specific hazards. The responsibilities of the medical staff and of the worker are also discussed. (author)

  12. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  13. Nutrition surveillance using a small open cohort: experience from Burkina Faso

    Directory of Open Access Journals (Sweden)

    Mathias Altmann

    2016-11-01

    Full Text Available Abstract Background Nutritional surveillance remains generally weak and early warning systems are needed in areas with high burden of acute under-nutrition. In order to enhance insight into nutritional surveillance, a community-based sentinel sites approach, known as the Listening Posts (LP Project, was piloted in Burkina Faso by Action Contre la Faim (ACF. This paper presents ACF’s experience with the LP approach and investigates potential selection and observational biases. Methods Six primary sampling units (PSUs were selected in each livelihood zone using the centric systematic area sampling methodology. In each PSU, 22 children aged between 6 and 24 months were selected by proximity sampling. The prevalence of GAM for each month from January 2011 to December 2013 was estimated using a Bayesian normal–normal conjugate analysis followed by PROBIT estimation. To validate the LP approach in detecting changes over time, the time trends of MUAC from LP and from five cross-sectional surveys were modelled using polynomial regression and compared by using a Wald test. The differences between prevalence estimates from the two data sources were used to assess selection and observational biases. Results The 95 % credible interval around GAM prevalence estimates using LP approach ranged between +6.5 %/−6.0 % on a prevalence of 36.1 % and +3.5 %/−2.9 % on a prevalence of 10.8 %. LP and cross-sectional surveys time trend models were well correlated (p = 0.6337. Although LP showed a slight but significant trend for GAM to decrease over time at a rate of −0.26 %/visit, the prevalence estimates from the two data sources showed good agreement over a 3-year period. Conclusions The LP methodology has proved to be valid in following trends of GAM prevalence for a period of 3 years without selection bias. However, a slight observational bias was observed, requiring a periodical reselection of the sentinel sites. This kind of surveillance

  14. Nutrition surveillance using a small open cohort: experience from Burkina Faso.

    Science.gov (United States)

    Altmann, Mathias; Fermanian, Christophe; Jiao, Boshen; Altare, Chiara; Loada, Martin; Myatt, Mark

    2016-01-01

    Nutritional surveillance remains generally weak and early warning systems are needed in areas with high burden of acute under-nutrition. In order to enhance insight into nutritional surveillance, a community-based sentinel sites approach, known as the Listening Posts (LP) Project, was piloted in Burkina Faso by Action Contre la Faim (ACF). This paper presents ACF's experience with the LP approach and investigates potential selection and observational biases. Six primary sampling units (PSUs) were selected in each livelihood zone using the centric systematic area sampling methodology. In each PSU, 22 children aged between 6 and 24 months were selected by proximity sampling. The prevalence of GAM for each month from January 2011 to December 2013 was estimated using a Bayesian normal-normal conjugate analysis followed by PROBIT estimation. To validate the LP approach in detecting changes over time, the time trends of MUAC from LP and from five cross-sectional surveys were modelled using polynomial regression and compared by using a Wald test. The differences between prevalence estimates from the two data sources were used to assess selection and observational biases. The 95 % credible interval around GAM prevalence estimates using LP approach ranged between +6.5 %/-6.0 % on a prevalence of 36.1 % and +3.5 %/-2.9 % on a prevalence of 10.8 %. LP and cross-sectional surveys time trend models were well correlated (p = 0.6337). Although LP showed a slight but significant trend for GAM to decrease over time at a rate of -0.26 %/visit, the prevalence estimates from the two data sources showed good agreement over a 3-year period. The LP methodology has proved to be valid in following trends of GAM prevalence for a period of 3 years without selection bias. However, a slight observational bias was observed, requiring a periodical reselection of the sentinel sites. This kind of surveillance project is suited to use in areas with high burden of acute under

  15. Spent fuel surveillance and monitoring methods

    International Nuclear Information System (INIS)

    1988-05-01

    The Technical Committee Meeting on ''Spent Fuel Surveillance and Monitoring Methods'' (27-30 October 1987) has been organized in accordance with recommendations of the International Standing Advisory Group on Spent Fuel Management during its second meeting in 1986. The aim of the meeting was to discuss the above questions with emphasis on current design and operation criteria, safety principles and licensing requirements and procedures in order to prevent: inadvertent criticality, undue radiation exposure, unacceptable release of radioactivity as well as control for loss of storage pool water, crud impact, water chemistry, distribution and behaviour of particulates in cooling water, oxidation of intact and failed fuel rods as a function of temperature and burnup; distribution of radiation and temperature through dry cask wall, monitoring of leakages from pools and gas escapes from dry storage facilities, periodical integrity tests of the containment barriers, responsibilities of organizations for the required operation, structure, staff and subordination, etc. The presentations of the Meeting were divided into two sessions: Spent fuel surveillance programmes and practice in Member States (4 papers); Experimental methods developed in support of spent fuel surveillance programmes (5 papers). A separate abstract was prepared for each of these papers. Refs, figs and tabs

  16. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  17. Comparison of embrittlement trend curves to high fluence surveillance results

    International Nuclear Information System (INIS)

    Bogaert, A.S.; Gerard, R.; Chaouadi, R.

    2011-01-01

    In the regulatory justification of the integrity of the reactor pressure vessels (RPV) for long term operation, use is made of predictive formulas (also called trend curves) to evaluate the RPV embrittlement (expressed in terms of RTNDT shifts) in function of fluence, chemical composition and in some cases temperature, neutron flux or product form. It has been shown recently that some of the existing or proposed trend curves tend to underpredict high dose embrittlement. Due to the scarcity of representative surveillance data at high dose, some test reactor results were used in these evaluations and raise the issue of representativeness of the accelerated test reactor irradiations (dose rate effects). In Belgium the surveillance capsules withdrawal schedule was modified in the nineties in order to obtain results corresponding to 60 years of operation or more with the initial surveillance program. Some of these results are already available and offer a good opportunity to test the validity of the predictive formulas at high dose. In addition, advanced surveillance methods are used in Belgium like the Master Curve, increased tensile tests, and microstructural investigations. These techniques made it possible to show the conservatism of the regulatory approach and to demonstrate increased margins, especially for the first generation units. In this paper the surveillance results are compared to different predictive formulas, as well as to an engineering hardening model developed at SCK.CEN. Generally accepted property-to-property correlations are critically revisited. Conclusions are made on the reliability and applicability of the embrittlement trend curves. (authors)

  18. Privacy Implications of Surveillance Systems

    DEFF Research Database (Denmark)

    Thommesen, Jacob; Andersen, Henning Boje

    2009-01-01

    This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed for vari......This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed...... for various purposes, even as a service for those being observed, but in any case they will to some degree invade their privacy. The model provided here can indicate how invasive any particular system may be – and be used to compare the invasiveness of different systems. Applying a functional approach......, the model is established by first considering the social function of privacy in everyday life, which in turn lets us determine which different domains will be considered as private, and finally identify the different types of privacy invasion. This underlying model (function – domain – invasion) then serves...

  19. Feasibility and acceptability of workers' health surveillance for fire fighters

    NARCIS (Netherlands)

    Plat, Marie-Christine J.; Frings-Dresen, Monique H. W.; Sluiter, Judith K.

    2011-01-01

    The objective of this study was to test the feasibility and acceptability of a new workers' health surveillance (WHS) for fire fighters in a Dutch pilot-implementation project. In three fire departments, between November 2007 and February 2009, feasibility was tested with respect to i) worker intent

  20. A model surveillance program based on regulatory experience

    International Nuclear Information System (INIS)

    Conte, R.J.

    1980-01-01

    A model surveillance program is presented based on regulatory experience. The program consists of three phases: Program Delineation, Data Acquistion and Data Analysis. Each phase is described in terms of key quality assurance elements and some current philosophies is the United States Licensing Program. Other topics include the application of these ideas to test equipment used in the surveillance progam and audits of the established program. Program Delineation discusses the establishment of administrative controls for organization and the description of responsibilities using the 'Program Coordinator' concept, with assistance from Data Acquisition and Analysis Teams. Ideas regarding frequency of surveillance testing are also presented. The Data Acquisition Phase discusses various methods for acquiring data including operator observations, test procedures, operator logs, and computer output, for trending equipment performance. The Data Analysis Phase discusses the process for drawing conclusions regarding component/equipment service life, proper application, and generic problems through the use of trend analysis and failure rate data. (orig.)

  1. Elementary Surveillance (ELS) and Enhanced Surveillance (EHS) Validation via Mode S Secondary Radar Surveillance

    National Research Council Canada - National Science Library

    Grappel, Robert D; Harris, Garrett S; Kozar, Mark J; Wiken, Randall T

    2008-01-01

    ...) and Enhanced Surveillance (ERS) data link applications. The intended audience for this report is an engineering staff assigned the task of implementing a monitoring system used to determine ELS and EHS compliance...

  2. Critical Surveillance Studies in the Information Society

    Directory of Open Access Journals (Sweden)

    Thomas Allmer

    2011-11-01

    Full Text Available The overall aim of this paper is to clarify how we can theorize and systemize economic surveillance. Surveillance studies scholars like David Lyon stress that economic surveillance such as monitoring consumers or the workplace are central aspects of surveillance societies. The approach that is advanced in this work recognizes the importance of the role of the economy in contemporary surveillance societies. The paper at hand constructs theoretically founded typologies in order to systemize the existing literature of surveillance studies and to analyze examples of surveillance. Therefore, it mainly is a theoretical approach combined with illustrative examples. This contribution contains a systematic discussion of the state of the art of surveillance and clarifies how different notions treat economic aspects of surveillance. In this work it is argued that the existing literature is insufficient for studying economic surveillance. In contrast, a typology of surveillance in the modern economy, which is based on foundations of a political economy approach, allows providing a systematic analysis of economic surveillance on the basis of current developments on the Internet. Finally, some political recommendations are drawn in order to overcome economic surveillance. This contribution can be fruitful for scholars who want to undertake a systematic analysis of surveillance in the modern economy and who want to study the field of surveillance critically.

  3. Effects of Interval Training Programme on Resting Heart Rate in ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Subjects with Hypertension: A Randomized Controlled Trial. Type of Article: Original ... Resting Heart Rate in Subjects with Hypertension — Lamina S. et al investigate the effect of interval .... changes in VO max) of interest. In the t-test. 2.

  4. Statistical intervals a guide for practitioners

    CERN Document Server

    Hahn, Gerald J

    2011-01-01

    Presents a detailed exposition of statistical intervals and emphasizes applications in industry. The discussion differentiates at an elementary level among different kinds of statistical intervals and gives instruction with numerous examples and simple math on how to construct such intervals from sample data. This includes confidence intervals to contain a population percentile, confidence intervals on probability of meeting specified threshold value, and prediction intervals to include observation in a future sample. Also has an appendix containing computer subroutines for nonparametric stati

  5. Active Surveillance Versus Watchful Waiting for Localized Prostate Cancer: A Model to Inform Decisions.

    Science.gov (United States)

    Loeb, Stacy; Zhou, Qinlian; Siebert, Uwe; Rochau, Ursula; Jahn, Beate; Mühlberger, Nikolai; Carter, H Ballentine; Lepor, Herbert; Braithwaite, R Scott

    2017-12-01

    An increasing proportion of prostate cancer is being managed conservatively. However, there are no randomized trials or consensus regarding the optimal follow-up strategy. To compare life expectancy and quality of life between watchful waiting (WW) versus different strategies of active surveillance (AS). A Markov model was created for US men starting at age 50, diagnosed with localized prostate cancer who chose conservative management by WW or AS using different testing protocols (prostate-specific antigen every 3-6 mo, biopsy every 1-5 yr, or magnetic resonance imaging based). Transition probabilities and utilities were obtained from the literature. Primary outcomes were life years and quality-adjusted life years (QALYs). Secondary outcomes include radical treatment, metastasis, and prostate cancer death. All AS strategies yielded more life years compared with WW. Lifetime risks of prostate cancer death and metastasis were, respectively, 5.42% and 6.40% with AS versus 8.72% and 10.30% with WW. AS yielded more QALYs than WW except in cohorts age >65 yr at diagnosis, or when treatment-related complications were long term. The preferred follow-up strategy was also sensitive to whether people value short-term over long-term benefits (time preference). Depending on the AS protocol, 30-41% underwent radical treatment within 10 yr. Extending the surveillance biopsy interval from 1 to 5 yr reduced life years slightly, with a 0.26 difference in QALYs. AS extends life more than WW, particularly for men with higher-risk features, but this is partly offset by the decrement in quality of life since many men eventually receive treatment. More intensive active surveillance protocols extend life more than watchful waiting, but this is partly offset by decrements in quality of life from subsequent treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Surveillance Camera Players / Bill Brown ; interv. Tilman Baumgärtel

    Index Scriptorium Estoniae

    Brown, Bill

    2006-01-01

    New Yorgis tegutsevast rühmitusest SCP (Turvakaamera Esinejad), mille rajas Bill Brown (sünd. 1959), temaga 2001. a. jaanuaris tehtud meiliintervjuu. SCP etendab näidendeid turvakaamerate ees, Internetis jagab informatsiooni oma tegevuse kohta. Tekstis: "...kuna SCP keskendub turvakaameratele, kasutades nende loogikat selle tehnoloogia enda vastu, siis võib öelda, et nad töötavad kommunikatsioonivõrkudega"

  7. Dijets at large rapidity intervals

    CERN Document Server

    Pope, B G

    2001-01-01

    Inclusive diet production at large pseudorapidity intervals ( Delta eta ) between the two jets has been suggested as a regime for observing BFKL dynamics. We have measured the dijet cross section for large Delta eta in pp collisions at square root s = 1800 and 630 GeV using the DOE detector. The partonic cross section increases strongly with the size of Delta eta . The observed growth is even stronger than expected on the basis of BFKL resummation in the leading logarithmic approximation. The growth of the partonic cross section can be accommodated with an effective BFKL intercept of alpha /sub BFKL/(20 GeV) = 1.65 +or- 0.07.

  8. Variational collocation on finite intervals

    International Nuclear Information System (INIS)

    Amore, Paolo; Cervantes, Mayra; Fernandez, Francisco M

    2007-01-01

    In this paper, we study a set of functions, defined on an interval of finite width, which are orthogonal and which reduce to the sinc functions when the appropriate limit is taken. We show that these functions can be used within a variational approach to obtain accurate results for a variety of problems. We have applied them to the interpolation of functions on finite domains and to the solution of the Schroedinger equation, and we have compared the performance of the present approach with others

  9. Risk stratification and detection of new colorectal neoplasms after colorectal cancer screening with faecal occult blood test

    DEFF Research Database (Denmark)

    Bjerrum, Andreas; Milter, Maya Christel; Andersen, Ole

    2015-01-01

    BACKGROUND: Limited data exist on adenoma surveillance as recommended in the European guidelines for quality assurance in colorectal cancer (CRC) screening and diagnosis after faecal occult blood test (FOBT) screening. OBJECTIVE: To assess the European guidelines for adenoma surveillance after CRC...... of CRC was higher in risk group C than A (RR 5.20, 95% confidence interval: 0.63-42.58), but not statistically significant. In risk group C, half of new advanced adenomas were detected within the first year and four of nine CRC were detected within 3 years. CONCLUSION: Risk stratification of adenoma...

  10. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  11. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  12. Active surveillance for localized prostate cancer

    DEFF Research Database (Denmark)

    Thostrup, Mathias; Thomsen, Frederik B; Iversen, Peter

    2018-01-01

    risk of biochemical recurrence were investigated and compared in men with very low-risk, low-risk and intermediate-risk PCa in the cohort. MATERIALS AND METHODS: In total, 451 men were followed on AS and monitored with prostate-specific antigen (PSA) tests, digital rectal examinations and rebiopsies......OBJECTIVE: The purpose of active surveillance (AS) is to reduce overtreatment of men with localized prostate cancer (PCa) without compromising survival. The objective of this study was to update a large Scandinavian single-center AS cohort. Furthermore, the use of curative treatment and subsequent...

  13. Project Surveillance and Maintenance Plan

    International Nuclear Information System (INIS)

    1985-09-01

    The Project Surveillance and Maintenance Plan (PSMP) describes the procedures that will be used by the US Department of Energy (DOE), or other agency as designated by the President to verify that inactive uranium tailings disposal facilities remain in compliance with licensing requirements and US Environmental Protection Agency (EPA) standards for remedial actions. The PSMP will be used as a guide for the development of individual Site Surveillance and Maintenance Plans (part of a license application) for each of the UMTRA Project sites. The PSMP is not intended to provide minimum requirements but rather to provide guidance in the selection of surveillance measures. For example, the plan acknowledges that ground-water monitoring may or may not be required and provides the [guidance] to make this decision. The Site Surveillance and Maintenance Plans (SSMPs) will form the basis for the licensing of the long-term surveillance and maintenance of each UMTRA Project site by the NRC. Therefore, the PSMP is a key milestone in the licensing process of all UMTRA Project sites. The Project Licensing Plan (DOE, 1984a) describes the licensing process. 11 refs., 22 figs., 8 tabs

  14. Indirect methods for reference interval determination - review and recommendations.

    Science.gov (United States)

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  15. Surveillance mission planning for UAVs in GPS-denied urban environment

    Science.gov (United States)

    Pengfei, Wang

    In this thesis, the issues involved in the mission planning of UAVs for city surveillance have been studied. In this thesis, the research includes two major parts. Firstly, a mission planning system is developed that generates mission plans for a group of fixed-wing UAVs with on-board gimballed cameras to provide continuous surveillance over an urban area. Secondly, the problem of perching location selection (as part of perch-and-stare surveillance mission) for rotary-wing UAVs in a GPS-denied environment is studied. In this kind of mission, a UAV is dispatched to perch on a roof of a building to keep surveillance on a given target. The proposed algorithms to UAV surveillance mission planning (fixed-wing and rotary-wing) have been implemented and tested. It represents an important step towards achieving autonomous planning in UAV surveillance missions.

  16. Present status of metrology of electro-optical surveillance systems

    Science.gov (United States)

    Chrzanowski, K.

    2017-10-01

    There has been a significant progress in equipment for testing electro-optical surveillance systems over the last decade. Modern test systems are increasingly computerized, employ advanced image processing and offer software support in measurement process. However, one great challenge, in form of relative low accuracy, still remains not solved. It is quite common that different test stations, when testing the same device, produce different results. It can even happen that two testing teams, while working on the same test station, with the same tested device, produce different results. Rapid growth of electro-optical technology, poor standardization, limited metrology infrastructure, subjective nature of some measurements, fundamental limitations from laws of physics, tendering rules and advances in artificial intelligence are major factors responsible for such situation. Regardless, next decade should bring significant improvements, since improvement in measurement accuracy is needed to sustain fast growth of electro-optical surveillance technology.

  17. Informatics enables public health surveillance

    Directory of Open Access Journals (Sweden)

    Scott J. N McNabb

    2017-01-01

    Full Text Available Over the past decade, the world has radically changed. New advances in information and communication technologies (ICT connect the world in ways never imagined. Public health informatics (PHI leveraged for public health surveillance (PHS, can enable, enhance, and empower essential PHS functions (i.e., detection, reporting, confirmation, analyses, feedback, response. However, the tail doesn't wag the dog; as such, ICT cannot (should not drive public health surveillance strengthening. Rather, ICT can serve PHS to more effectively empower core functions. In this review, we explore promising ICT trends for prevention, detection, and response, laboratory reporting, push notification, analytics, predictive surveillance, and using new data sources, while recognizing that it is the people, politics, and policies that most challenge progress for implementation of solutions.

  18. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  19. A Review of OIE Country Status Recovery Using Vaccinate-to-Live Versus Vaccinate-to-Die Foot-and-Mouth Disease Response Policies I: Benefits of Higher Potency Vaccines and Associated NSP DIVA Test Systems in Post-Outbreak Surveillance.

    Science.gov (United States)

    Barnett, P V; Geale, D W; Clarke, G; Davis, J; Kasari, T R

    2015-08-01

    To rapidly return to trade, countries with OIE status, FMD-free country where vaccination is not practised, have destroyed emergency vaccinated animals, raising ethical concerns with respect to social values, the environment, animal welfare and global food security. This two-part review explores whether science could support eligibility to return to previous OIE status in 3 months irrespective of vaccinate-to-live or vaccinate-to-die policies. Here, we examine the benefits of higher potency (≥ 6 PD50 ), high-purity vaccines formulated from antigen banks for emergency use, their efficacy and performance in differentiating infected from vaccinated animals (DIVA) assays for post-outbreak surveillance. From an intensive programme of research, we conclude that high-quality, higher potency vaccines are proven to reduce FMD virus (FMDV) subclinical circulation and the risk of carriers. Broader coverage than predicted by serology suggests the potential to hold a few 'key' vaccine strains improving logistics and reducing the financial burden of antigen banks. The OIE should adopt formal definitions for emergency vaccination and emergency vaccines. In terms of supportive tools, we consider that the lack of OIE recognition of DIVA tests other than those of PANAFTOSA in cattle is a shortcoming. There is need for research on maternal antibody interference with DIVA tests and on the use of such tests to establish whether greater purification of vaccines improves performance. We consider that alignment of waiting periods for vaccinate-to-live and vaccinate-to-die in OIE Code Article 8.5.9 1 b. and c. is feasible until an acceptable level of statistical certainty for surveillance or target probability of freedom is established to substantiate the absence of FMDV infection or circulation. It is surveillance intensity rather than waiting periods that establishes the risk of residual FMDV. EU Directive 2003/85/EC implicitly recognizes this, permitting derogation of the OIE waiting

  20. Some Characterizations of Convex Interval Games

    NARCIS (Netherlands)

    Brânzei, R.; Tijs, S.H.; Alparslan-Gok, S.Z.

    2008-01-01

    This paper focuses on new characterizations of convex interval games using the notions of exactness and superadditivity. We also relate big boss interval games with concave interval games and obtain characterizations of big boss interval games in terms of exactness and subadditivity.

  1. Surveillance of avian influenza in the Caribbean through the Caribbean Animal Health Network: surveillance tools and epidemiologic studies.

    Science.gov (United States)

    Lefrançois, T; Hendrikx, P; Ehrhardt, N; Millien, M; Gomez, L; Gouyet, L; Gaidet, N; Gerbier, G; Vachiéry, N; Petitclerc, F; Carasco-Lacombe, C; Pinarello, V; Ahoussou, S; Levesque, A; Gongora, H V; Trotman, M

    2010-03-01

    The Caribbean region is considered to be at risk for avian influenza (AI) due to a large backyard poultry system, an important commercial poultry production system, the presence of migratory birds, and disparities in the surveillance systems. The Caribbean Animal Health Network (CaribVET) has developed tools to implement AI surveillance in the region with the goals to have 1) a regionally harmonized surveillance protocol and specific web pages for AI surveillance on www.caribvet.net, and 2) an active and passive surveillance for AI in domestic and wild birds. A diagnostic network for the Caribbean, including technology transfer and AI virus molecular diagnostic capability in Guadeloupe (real-time reverse transcription-polymerase chain reaction for the AI virus matrix gene), was developed. Between 2006 and 2009, 627 samples from four Caribbean countries were tested for three circumstances: importation purposes, following a clinical suspicion of AI, or through an active survey of wild birds (mainly waders) during the southward and northward migration periods in Guadeloupe. None of the samples tested were positive, suggesting a limited role of these species in the AI virus ecology in the Caribbean. Following low pathogenic H5N2 outbreaks in the Dominican Republic in 2007, a questionnaire was developed to collect data for a risk analysis of AI spread in the region through fighting cocks. The infection pathway of the Martinique commercial poultry sector by AI, through introduction of infected cocks, was designed, and recommendations were provided to the Caribbean Veterinary Services to improve cock movement control and biosecurity measures. The CaribVET and its organization allowed interaction between diagnostic and surveillance tools on the one hand and epidemiologic studies on the other, both of them developed in congruence with regional strategies. Together, these CaribVET activities contribute to strengthening surveillance of avian influenza virus (AIV) in the

  2. Containment and Surveillance Equipment Compendium

    International Nuclear Information System (INIS)

    Luetters, F.O.

    1980-02-01

    The Containment and Surveillance Equipment Compendium contains information sections describing the application and status of seals, optical surveillance systems, and monitors for international safeguards systems. The Compendium is a collection of information on equipment in use (generally by the IAEA) or under development in the US in diverse programs being conducted at numerous facilities under different sponsors. The Compendium establishes a baseline for the status and applications of C/S equipment and is a tool to assist in the planning of future C/S hardware development activities. The Appendix contains design concepts which can be developed to meet future goals

  3. Improving Situational Awareness in camera surveillance by combining top-view maps with camera images

    NARCIS (Netherlands)

    Kooi, F.L.; Zeeders, R.

    2009-01-01

    The goal of the experiment described is to improve today's camera surveillance in public spaces. Three designs with the camera images combined on a top-view map were compared to each other and to the current situation in camera surveillance. The goal was to test which design makes spatial

  4. Burden of waiting for surveillance CT colonography in patients with screen-detected 6-9 mm polyps

    Energy Technology Data Exchange (ETDEWEB)

    Tutein Nolthenius, Charlotte J. [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Boellaard, Thierry N.; Nio, C.Y.; Bipat, Shandra; Stoker, Jaap [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Haan, Margriet C. de [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Thomeer, Maarten G.J. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Montauban van Swijndregt, Alexander D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Essink-Bot, Marie-Louise [University of Amsterdam, Public Health, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Kuipers, Ernst J. [Erasmus University Medical Center, Gastroenterology and Hepatology, Rotterdam (Netherlands); Erasmus University Medical Center, Internal medicine, Rotterdam (Netherlands); Dekker, Evelien [University of Amsterdam, Gastroenterology and Hepatology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands)

    2016-11-15

    We assessed the burden of waiting for surveillance CT colonography (CTC) performed in patients having 6-9 mm colorectal polyps on primary screening CTC. Additionally, we compared the burden of primary and surveillance CTC. In an invitational population-based CTC screening trial, 101 persons were diagnosed with <3 polyps 6-9 mm, for which surveillance CTC after 3 years was advised. Validated questionnaires regarding expected and perceived burden (5-point Likert scales) were completed before and after index and surveillance CTC, also including items on burden of waiting for surveillance CTC. McNemar's test was used for comparison after dichotomization. Seventy-eight (77 %) of 101 invitees underwent surveillance CTC, of which 66 (85 %) completed the expected and 62 (79 %) the perceived burden questionnaire. The majority of participants (73 %) reported the experience of waiting for surveillance CTC as 'never' or 'only sometimes' burdensome. There was almost no difference in expected and perceived burden between surveillance and index CTC. Waiting for the results after the procedure was significantly more burdensome for surveillance CTC than for index CTC (23 vs. 8 %; p = 0.012). Waiting for surveillance CTC after primary CTC screening caused little or no burden for surveillance participants. In general, the burden of surveillance and index CTC were comparable. (orig.)

  5. Automated recommendation for cervical cancer screening and surveillance.

    Science.gov (United States)

    Wagholikar, Kavishwar B; MacLaughlin, Kathy L; Casey, Petra M; Kastner, Thomas M; Henry, Michael R; Hankey, Ronald A; Peters, Steve G; Greenes, Robert A; Chute, Christopher G; Liu, Hongfang; Chaudhry, Rajeev

    2014-01-01

    Because of the complexity of cervical cancer prevention guidelines, clinicians often fail to follow best-practice recommendations. Moreover, existing clinical decision support (CDS) systems generally recommend a cervical cytology every three years for all female patients, which is inappropriate for patients with abnormal findings that require surveillance at shorter intervals. To address this problem, we developed a decision tree-based CDS system that integrates national guidelines to provide comprehensive guidance to clinicians. Validation was performed in several iterations by comparing recommendations generated by the system with those of clinicians for 333 patients. The CDS system extracted relevant patient information from the electronic health record and applied the guideline model with an overall accuracy of 87%. Providers without CDS assistance needed an average of 1 minute 39 seconds to decide on recommendations for management of abnormal findings. Overall, our work demonstrates the feasibility and potential utility of automated recommendation system for cervical cancer screening and surveillance.

  6. Conversion to use of digital chest images for surveillance of coal workers' pneumoconiosis (black lung).

    Science.gov (United States)

    Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward

    2009-01-01

    To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.

  7. Regional Disease Surveillance Meeting - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lesperance, Ann M.; Mahy, Heidi A.

    2006-08-08

    On June 1, 2006, public health officials working in surveillance, epidemiological modeling, and information technology communities from the Seattle/Tacoma area and State of Washington met with members of the Pacific Northwest National Laboratory (PNNL) to discuss the current state of disease surveillance and gaps and needs to improve the current systems. The meeting also included a discussion of PNNL initiatives that might be appropriate to enhance disease surveillance and the current tools being used for disease surveillance. Participants broke out into two groups to identify critical gaps and needs for improving a surveillance system, and discuss the requirements for developing improved surveillance. Each group developed a list of key priorities summarizing the requirements for improved surveillance. The objective of this meeting was to work towards the development of an improved disease surveillance system.

  8. Inappropriate colonoscopic surveillance of hyperplastic polyps.

    LENUS (Irish Health Repository)

    Keane, R A

    2011-11-15

    Colonoscopic surveillance of hyperplastic polyps alone is controversial and may be inappropriate. The colonoscopy surveillance register at a university teaching hospital was audited to determine the extent of such hyperplastic polyp surveillance. The surveillance endoscopy records were reviewed, those patients with hyperplastic polyps were identified, their clinical records were examined and contact was made with each patient. Of the 483 patients undergoing surveillance for colonic polyps 113 (23%) had hyperplastic polyps alone on last colonoscopy. 104 patients remained after exclusion of those under appropriate surveillance. 87 of the 104 patients (84%) were successfully contacted. 37 patients (8%) were under appropriate colonoscopic surveillance for a significant family history of colorectal carcinoma. 50 (10%) patients with hyperplastic polyps alone and no other clinical indication for colonoscopic surveillance were booked for follow up colonoscopy. This represents not only a budgetary but more importantly a clinical opportunity cost the removal of which could liberate valuable colonoscopy time for more appropriate indications.

  9. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  10. Surveillance by diagnostic microbiology laboratories

    African Journals Online (AJOL)

    account for almost threequarters of all Acinetobacter baumannii bloodstream infections, supporting the decision to include colistin or tobramycin as empirical treatment options for ICU patients with suspected Gramnegative sepsis. The dissemination and utilisation of surveillance data is crucial if they are to impact on patient ...

  11. Symbolic power, robotting, and surveilling

    DEFF Research Database (Denmark)

    Skovsmose, Ole

    2012-01-01

    describes as it prioritises is discussed with reference to robotting and surveillance. In general, the symbolic power of mathematics and formal languages is summarised through the observations: that mathematics treats parts and properties as autonomous, that it dismembers what it addresses and destroys...

  12. Oak Ridge Research reactor shutdown maintenance and surveillance

    International Nuclear Information System (INIS)

    Coleman, G.H.; Laughlin, D.L.

    1991-05-01

    The Department of Energy ordered the Oak Ridge Research Reactor to be placed in permanent shutdown on July 14, 1987. The paper outlines routine maintenance activities and surveillance tests performed April through September, 1990, on the reactor instrumentation and controls, process system, and the gaseous waste filter system. Preparations are being made to transfer the facility to the Remedial Action Program. 6 tabs

  13. Risk prediction of cardiovascular death based on the QTc interval

    DEFF Research Database (Denmark)

    Nielsen, Jonas B; Graff, Claus; Rasmussen, Peter V

    2014-01-01

    electrocardiograms from 173 529 primary care patients aged 50-90 years were collected during 2001-11. The Framingham formula was used for heart rate-correction of the QT interval. Data on medication, comorbidity, and outcomes were retrieved from administrative registries. During a median follow-up period of 6......AIMS: Using a large, contemporary primary care population we aimed to provide absolute long-term risks of cardiovascular death (CVD) based on the QTc interval and to test whether the QTc interval is of value in risk prediction of CVD on an individual level. METHODS AND RESULTS: Digital...

  14. Hepatocellular Carcinoma Surveillance Rates in Commercially Insured Patients with Non-Cirrhotic Chronic Hepatitis B

    Science.gov (United States)

    Goldberg, David S.; Valderrama, Adriana; Kamalakar, Rajesh; Sansgiry, Sujit S; Babajanyan, Svetlana; Lewis, James D.

    2015-01-01

    AASLD and EASL guidelines recommend biannual hepatocellular carcinoma (HCC) screening for non-cirrhotic patients with chronic hepatitis B infection (HBV), yet there are no data estimating surveillance rates or factors associated with surveillance. We performed a retrospective cohort study of U.S. patients using the Truven Health Analytics databases from 2006-2010, and identified patients with non-cirrhotic chronic HBV. Surveillance patterns were characterized using categorical and continuous outcomes, with the continuous measure of the proportion of time “up-to-date” with surveillance (PUTDS), with the six-month interval following each ultrasound categorized as “up-to-date.” During a median follow-up of 26.0 (IQR: 16.2-40.0) months among 4,576 non-cirrhotic patients with chronic HBV (median age: 44 years, IQR: 36-52), only 306 (6.7%) had complete surveillance (one ultrasound every 6-month interval), 2,727 (59.6%) incomplete (≥1 ultrasound), and 1,543 (33.7%) none. The mean PUTDS was 0.34 ± 0.29, and the median was 0.32 (IQR: 0.03-0.52). In multinomial logistic regression models, patients diagnosed by a non-gastroenterologist were significantly less likely to have complete surveillance (psurveillance. Patients with HIV had an absolute decrease in the PUTDS of 0.24, while patients in less populated rural areas had an absolute decrease of 0.10. HCC surveillance rates in non-cirrhotic patients with chronic HBV in the United States are poor, and lower than reported rates of HCC surveillance in cirrhotic patients. PMID:25581816

  15. Approaches to canine health surveillance.

    Science.gov (United States)

    O'Neill, Dan G; Church, David B; McGreevy, Paul D; Thomson, Peter C; Brodbelt, Dave C

    2014-01-01

    Effective canine health surveillance systems can be used to monitor disease in the general population, prioritise disorders for strategic control and focus clinical research, and to evaluate the success of these measures. The key attributes for optimal data collection systems that support canine disease surveillance are representativeness of the general population, validity of disorder data and sustainability. Limitations in these areas present as selection bias, misclassification bias and discontinuation of the system respectively. Canine health data sources are reviewed to identify their strengths and weaknesses for supporting effective canine health surveillance. Insurance data benefit from large and well-defined denominator populations but are limited by selection bias relating to the clinical events claimed and animals covered. Veterinary referral clinical data offer good reliability for diagnoses but are limited by referral bias for the disorders and animals included. Primary-care practice data have the advantage of excellent representation of the general dog population and recording at the point of care by veterinary professionals but may encounter misclassification problems and technical difficulties related to management and analysis of large datasets. Questionnaire surveys offer speed and low cost but may suffer from low response rates, poor data validation, recall bias and ill-defined denominator population information. Canine health scheme data benefit from well-characterised disorder and animal data but reflect selection bias during the voluntary submissions process. Formal UK passive surveillance systems are limited by chronic under-reporting and selection bias. It is concluded that active collection systems using secondary health data provide the optimal resource for canine health surveillance.

  16. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  17. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  18. Tales From the Unit Interval

    DEFF Research Database (Denmark)

    Nielsen, Thor Pajhede

    Testing the validity of Value-at-Risk (VaR) forecasts, or backtesting, is an integral part of modern market risk management and regulation. This is often done by applying independence and coverage tests developed in Christoffersen (1998) to so-called hit-sequences derived from VaR forecasts...... key observation of the studies is that higher order dependence in the hit-sequences may cause the observed lower power performance. We propose to generalize the backtest framework for Value-at-Risk forecasts, by extending the original first order dependence of Christoffersen (1998) to allow...... for a higher, or k’th, order dependence. We provide closed form expressions for the tests as well as asymptotic theory. Not only do the generalized tests have power against k’th order dependence by definition, but also included simulations indicate improved power performance when replicating the aforementioned...

  19. The second birth interval in Egypt: the role of contraception

    OpenAIRE

    Baschieri, Angela

    2004-01-01

    The paper discusses problems of model specification in birth interval analysis. Using Bongaarts’s conceptual framework on the proximate determinants on fertility, the paper tests the hypothesis that all important variation in fertility is captured by differences in marriage, breastfeeding, contraception and induced abortion. The paper applies a discrete time hazard model to study the second birth interval using data from the Egyptian Demographic and Health Survey 2000 (EDHS), and the month by...

  20. LWR-PV Surveillance Dosimetry Improvement Program review graphics

    International Nuclear Information System (INIS)

    McElroy, W.N.; Gold, R.; Gutherie, G.L.

    1979-10-01

    A primary objective of the multilaboratory program is to prepare an updated and improved set of dosimetry, damage correlation, and the associated reactor analysis ASTM standards for LWR-PV irradiation surveillance programs. Supporting this objective are a series of analytical and experimental validation and calibration studies in Benchmark Neutron Fields, reactor Test Regions, and operating power reactor Surveillance Positions. These studies will establish and certify the precision and accuracy of the measurement and predictive methods which are recommended for use in these standards. Consistent and accurate measurement and data analysis techniques and methods, therefore, will have been developed and validated along with guidelines for required neutron field calculations that are used to (1) correlate changes in material properties with the characteristics of the neutron radiation field and (2) predict pressure vessel steel toughness and embrittlement from power reactor surveillance data