WorldWideScience

Sample records for surveillance test intervals

  1. Risk based surveillance test interval optimization

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1995-01-01

    First step towards the risk based regulation is to determine the optimal surveillance test intervals for the safety equipment which is tested at nuclear power plant operation. In the paper we have presented the process of optimal surveillance test interval optimization from our perspective. It consist of three levels: component level, system level and plant level. It bases on the results of the Probabilistic Safety Assessment and is focused to minimize risk. At component and system level the risk measure is component or system mean unavailability respectively. At plant level the risk measure is core damage frequency. (author)

  2. Optimization of Allowed Outage Time and Surveillance Test Intervals

    International Nuclear Information System (INIS)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun

    2015-01-01

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  3. Quantitative evaluation of surveillance test intervals including test-caused risks

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1992-02-01

    Concerns have been raised regarding the adverse safety impact of surveillance testing and generally overburdensome surveillance requirements. To evaluate these concerns, the risk-effectiveness with the beneficial risk impact. This report defines the adverse effects of surveillance testing from a risk perspective, and then presents the methodology by which the adverse risk impact can be quantified, focusing on two important kinds of adverse risk impact of surveillance testing: risk impact of test-caused trips and risk impact of test-caused equipment wear. Using the methodology presented, these risk impacts are evaluated for a selected set of surveillance tests for demonstration examples. The results of the risk-effectiveness evaluation are provided along with the insights from the sensitivity analyses

  4. Effects of human errors on the determination of surveillance test interval

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Koo, Bon Hyun

    1990-01-01

    This paper incorporates the effects of human error relevant to the periodic test on the unavailability of the safety system as well as the component unavailability. Two types of possible human error during the test are considered. One is the possibility that a good safety system is inadvertently left in a bad state after the test (Type A human error) and the other is the possibility that bad safety system is undetected upon the test (Type B human error). An event tree model is developed for the steady-state unavailability of safety system to determine the effects of human errors on the component unavailability and the test interval. We perform the reliability analysis of safety injection system (SIS) by applying aforementioned two types of human error to safety injection pumps. Results of various sensitivity analyses show that; 1) the appropriate test interval decreases and steady-state unavailability increases as the probabilities of both types of human errors increase, and they are far more sensitive to Type A human error than Type B and 2) the SIS unavailability increases slightly as the probability of Type B human error increases, and significantly as the probability of Type A human error increases. Therefore, to avoid underestimation, the effects of human error should be incorporated in the system reliability analysis which aims at the relaxations of the surveillance test intervals, and Type A human error has more important effect on the unavailability and surveillance test interval

  5. Risk-Based Allowed Outage Time and Surveillance Test Interval Extensions for Angra 1

    Directory of Open Access Journals (Sweden)

    Sonia M. Orlando Gibelli

    2012-01-01

    Full Text Available In this work, Probabilistic Safety Assessment (PSA is used to evaluate Allowed Outage Times (AOT and Surveillance Test Intervals (STI extensions for three Angra 1 nuclear power plant safety systems. The interest in such an analysis lies on the fact that PSA comprises a risk-based tool for safety evaluation and has been increasingly applied to support both the regulatory and the operational decision-making processes. Regarding Angra 1, among other applications, PSA is meant to be an additional method that can be used by the utility to justify Technical Specification relaxation to the Brazilian regulatory body. The risk measure used in this work is the Core Damage Frequency, obtained from the Angra 1 Level 1 PSA study. AOT and STI extensions are evaluated for the Safety Injection, Service Water and Auxiliary Feedwater Systems using the SAPHIRE code. In order to compensate for the risk increase caused by the extensions, compensatory measures as (1 test of redundant train prior to entering maintenance and (2 staggered test strategy are proposed. Results have shown that the proposed AOT extensions are acceptable for two of the systems with the implementation of compensatory measures whereas STI extensions are acceptable for all three systems.

  6. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hyun; You, Young Woo; Cho, Jae Seon; Huh, Chang Wook; Kim, Do Hyoung; Kim, Ju Youl; Kim, Yoon Ik; Yang, Hui Chang; Park, Kang Min [Seoul National Univ., Seoul (Korea, Republic of)

    1998-03-15

    The objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Internal(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plant safety. In this study, the survey about the assessment methodologies, modelings and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. The sensitivity analyses about the failure factors of the components are performed in the bases of the and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code. The qualitative assessment for the STI/AOR of RPS/ESFAS assured safety the most important system in the nuclear power plant are performed.

  7. Surveillance intervals for small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Bown, Matthew J; Sweeting, Michael J; Brown, Louise C

    2013-01-01

    Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture.......Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture....

  8. Risk-based evaluation of allowed outage time and surveillance test interval extensions for nuclear power plants

    International Nuclear Information System (INIS)

    Gibelli, Sonia Maria Orlando

    2008-03-01

    The main goal of this work is, through the use of Probabilistic Safety Analysis (PSA), to evaluate Technical Specification (TS) Allowed Outage Times (AOT) and Surveillance Test Intervals (STI) extensions for Angra 1 nuclear power plant. PSA has been incorporated as an additional tool, required as part of NPP licensing process. The risk measure used in this work is the Core Damage Frequency (CDF), obtained from the Angra 1 PSA Level 1. AOT and STI extensions are calculated for the Safety Injection System (SIS), Service water System (SAS) and Auxiliary Feedwater System (AFS) through the use of SAPHIRE code. In order to compensate for the risk increase caused by the extensions, compensatory measures as test of redundant train prior to entering maintenance and staggered test strategy are proposed. Results have shown that the proposed AOT extensions are acceptable for the SIS and SAS with the implementation of compensatory measures. The proposed AOT extension is not acceptable for the AFS. The STI extensions are acceptable for all three systems. (author)

  9. A Sensitivity Study of Human Errors in Optimizing Surveillance Test Interval (STI) and Allowed Outage Time (AOT) of Standby Safety System

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Shin, Won Ky; You, Young Woo; Yang, Hui Chang

    1998-01-01

    In most cases, the surveillance test intervals (STIs), allowed outage times (AOTS) and testing strategies of safety components in nuclear power plant are prescribed in plant technical specifications. And, in general, it is required that standby safety system shall be redundant (i.e., composed of multiple components) and these components are tested by either staggered test strategy or sequential test strategy. In this study, a linear model is presented to incorporate the effects of human errors associated with test into the evaluation of unavailability. The average unavailabilities of 1/4, 2/4 redundant systems are computed considering human error and testing strategy. The adverse effects of test on system unavailability, such as component wear and test-induced transient have been modelled. The final outcome of this study would be the optimized human error domain from 3-D human error sensitivity analysis by selecting finely classified segment. The results of sensitivity analysis show that the STI and AOT can be optimized provided human error probability is maintained within allowable range. (authors)

  10. An analysis for risk impact of Emergency Diesel Generator on modified Surveillance Test Interval by considering failure due to demand stress

    International Nuclear Information System (INIS)

    Choi, Sun Yeong; Lee, Jooho; Yang, Joon-Eon

    2010-01-01

    The common practice for the estimation of the probability of a component failure to start on demand is to lump together standby failures and failures due to the stress induced by the demand itself. In this paper, a failure by demand stress as well as a standby failure is considered separately to estimate the probability of a failure on demand when a Surveillance Test Interval (STI) is modified. The proposed estimation method is based on α, the ratio of the probability of a failure by demand stress to that of a failure on demand. The estimate of α, however, should be changed when an STI is modified. An estimation method for α', the changed parameter corresponding to α under an STI modification is also suggested. With the proposed estimation method and the estimate of α' from a plant specific database, a risk impact analysis due to an STI modification for the Emergency Diesel Generator (EDG) of UCN units 3 and 4 is performed. From the sensitivity analysis, the following conclusions can de derived: if it is assumed that all failures occur during the standby time, as it is the case in the common practice, the results can overestimate the risk impact. And it is required to construct a component reliability database containing detailed information on the failure types to recognize whether a component failure occurs during a standby time or a test.

  11. Interval algebra: an effective means of scheduling surveillance radar networks

    CSIR Research Space (South Africa)

    Focke, RW

    2015-05-01

    Full Text Available Interval Algebra provides an effective means to schedule surveillance radar networks, as it is a temporal ordering constraint language. Thus it provides a solution to a part of resource management, which is included in the revised Data Fusion...

  12. Determining the optimal surveillance interval after a colonoscopic polypectomy for the Korean population?

    Directory of Open Access Journals (Sweden)

    Jung Lok Lee

    2017-01-01

    Full Text Available Background/Aims: Western surveillance strategies cannot be directly adapted to the Korean population. The aim of this study was to estimate the risk of metachronous neoplasia and the optimal surveillance interval in the Korean population.Methods: Clinical and pathological data from index colonoscopy performed between June 2006 and July 2008 and who had surveillance colonoscopies up to May 2015 were compared between low- and high-risk adenoma (LRA and HRA groups. The 3- and 5-year cumulative risk of metachronous colorectal neoplasia in both groups were compared.Results: Among 895 eligible patients, surveillance colonoscopy was performed in 399 (44.6%. Most (83.3% patients with LRA had a surveillance colonoscopy within 5 years and 70.2% of patients with HRA had a surveillance colonoscopy within 3 years. The cumulative risk of metachronous advanced adenoma was 3.2% within 5 years in the LRA group and only 1.7% within 3 years in the HRA group. The risk of metachronous neoplasia was similar between the surveillance interval of <5 and ≥5 years in the LRA group; however, it was slightly higher at surveillance interval of ≥3 than <3 years in the HRA group (9.4% vs. 2.4%. In multivariate analysis, age and the ≥3-year surveillance interval were significant independent risk factors for metachronous advanced adenoma (P=0.024 and P=0.030, respectively.Conclusions: Patients had a surveillance colonoscopy before the recommended guidelines despite a low risk of metachronous neoplasia. However, the risk of metachronous advanced adenoma was increased in elderly patients and those with a ≥3-year surveillance interval.

  13. Variation in polyp size estimation among endoscopists and impact on surveillance intervals.

    Science.gov (United States)

    Chaptini, Louis; Chaaya, Adib; Depalma, Fedele; Hunter, Krystal; Peikin, Steven; Laine, Loren

    2014-10-01

    Accurate estimation of polyp size is important because it is used to determine the surveillance interval after polypectomy. To evaluate the variation and accuracy in polyp size estimation among endoscopists and the impact on surveillance intervals after polypectomy. Web-based survey. A total of 873 members of the American Society for Gastrointestinal Endoscopy. Participants watched video recordings of 4 polypectomies and were asked to estimate the polyp sizes. Proportion of participants with polyp size estimates within 20% of the correct measurement and the frequency of incorrect surveillance intervals based on inaccurate size estimates. Polyp size estimates were within 20% of the correct value for 1362 (48%) of 2812 estimates (range 39%-59% for the 4 polyps). Polyp size was overestimated by >20% in 889 estimates (32%, range 15%-49%) and underestimated by >20% in 561 (20%, range 4%-46%) estimates. Incorrect surveillance intervals because of overestimation or underestimation occurred in 272 (10%) of the 2812 estimates (range 5%-14%). Participants in a private practice setting overestimated the size of 3 or of all 4 polyps by >20% more often than participants in an academic setting (difference = 7%; 95% confidence interval, 1%-11%). Survey design with the use of video clips. Substantial overestimation and underestimation of polyp size occurs with visual estimation leading to incorrect surveillance intervals in 10% of cases. Our findings support routine use of measurement tools to improve polyp size estimates. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  15. Existence test for asynchronous interval iterations

    DEFF Research Database (Denmark)

    Madsen, Kaj; Caprani, O.; Stauning, Ole

    1997-01-01

    In the search for regions that contain fixed points ofa real function of several variables, tests based on interval calculationscan be used to establish existence ornon-existence of fixed points in regions that are examined in the course ofthe search. The search can e.g. be performed...... as a synchronous (sequential) interval iteration:In each iteration step all components of the iterate are calculatedbased on the previous iterate. In this case it is straight forward to base simple interval existence and non-existencetests on the calculations done in each step of the iteration. The search can also...... on thecomponentwise calculations done in the course of the iteration. These componentwisetests are useful for parallel implementation of the search, sincethe tests can then be performed local to each processor and only when a test issuccessful do a processor communicate this result to other processors....

  16. Predicting Driver Behavior during the Yellow Interval Using Video Surveillance

    Directory of Open Access Journals (Sweden)

    Juan Li

    2016-12-01

    Full Text Available At a signalized intersection, drivers must make a stop/go decision at the onset of the yellow signal. Incorrect decisions would lead to red light running (RLR violations or crashes. This study aims to predict drivers’ stop/go decisions and RLR violations during yellow intervals. Traffic data such as vehicle approaching speed, acceleration, distance to the intersection, and occurrence of RLR violations are gathered by a Vehicle Data Collection System (VDCS. An enhanced Gaussian Mixture Model (GMM is used to extract moving vehicles from target lanes, and the Kalman Filter (KF algorithm is utilized to acquire vehicle trajectories. The data collected from the VDCS are further analyzed by a sequential logit model, and the relationship between drivers’ stop/go decisions and RLR violations is identified. The results indicate that the distance of vehicles to the stop line at the onset of the yellow signal is an important predictor for both drivers’ stop/go decisions and RLR violations. In addition, vehicle approaching speed is a contributing factor for stop/go decisions. Furthermore, the accelerations of vehicles after the onset of the yellow signal are positively related to RLR violations. The findings of this study can be used to predict the probability of drivers’ RLR violations and improve traffic safety at signalized intersections.

  17. Risk based test interval and maintenance optimisation - Application and uses

    International Nuclear Information System (INIS)

    Sparre, E.

    1999-10-01

    The project is part of an IAEA co-ordinated Research Project (CRP) on 'Development of Methodologies for Optimisation of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs'. The purpose of the project is to investigate the sensitivity of the results obtained when performing risk based optimisation of the technical specifications. Previous projects have shown that complete LPSA models can be created and that these models allow optimisation of technical specifications. However, these optimisations did not include any in depth check of the result sensitivity with regards to methods, model completeness etc. Four different test intervals have been investigated in this study. Aside from an original, nominal, optimisation a set of sensitivity analyses has been performed and the results from these analyses have been compared to the original optimisation. The analyses indicate that the result of an optimisation is rather stable. However, it is not possible to draw any certain conclusions without performing a number of sensitivity analyses. Significant differences in the optimisation result were discovered when analysing an alternative configuration. Also deterministic uncertainties seem to affect the result of an optimisation largely. The sensitivity of failure data uncertainties is important to investigate in detail since the methodology is based on the assumption that the unavailability of a component is dependent on the length of the test interval

  18. Surveillance test of OWL-2 inpile tube

    International Nuclear Information System (INIS)

    Shimizu, Masatsugu; Itoh, Noboru

    1976-08-01

    A series of irradiation surveillance tests performed in integrity evaluation of an inpile tube for the test loop OWL-2 are described. Specimens were exposed to the neutron fluences from 1 x 10 20 to 3.4 x 10 21 n/cm 2 (>1 MeV), and subjected to post-irradiation tensile test at room temperature and service temperature 285 0 C. The strength increased and the ductility decreased with increasing neutron fluence. The reduction in fracture ductility due to neutron irradiation in the fluence range was insignificant, and the elongation of 33% was retained even for the maximum neutron fluence at 285 0 C. Little decrease of the ductility with fluence indicates that the tube would be in service for long time, ie to the integral fluence of 3.4 x 10 21 n/cm 2 . (auth.)

  19. Laboratory test surveillance following acute kidney injury.

    Directory of Open Access Journals (Sweden)

    Michael E Matheny

    Full Text Available Patients with hospitalized acute kidney injury (AKI are at increased risk for accelerated loss of kidney function, morbidity, and mortality. We sought to inform efforts at improving post-AKI outcomes by describing the receipt of renal-specific laboratory test surveillance among a large high-risk cohort.We acquired clinical data from the Electronic health record (EHR of 5 Veterans Affairs (VA hospitals to identify patients hospitalized with AKI from January 1st, 2002 to December 31st, 2009, and followed these patients for 1 year or until death, enrollment in palliative care, or improvement in renal function to estimated GFR (eGFR ≥ 60 L/min/1.73 m(2. Using demographic data, administrative codes, and laboratory test data, we evaluated the receipt and timing of outpatient testing for serum concentrations of creatinine and any as well as quantitative proteinuria recommended for CKD risk stratification. Additionally, we reported the rate of phosphorus and parathyroid hormone (PTH monitoring recommended for chronic kidney disease (CKD patients.A total of 10,955 patients admitted with AKI were discharged with an eGFR<60 mL/min/1.73 m2. During outpatient follow-up at 90 and 365 days, respectively, creatinine was measured on 69% and 85% of patients, quantitative proteinuria was measured on 6% and 12% of patients, PTH or phosphorus was measured on 10% and 15% of patients.Measurement of creatinine was common among all patients following AKI. However, patients with AKI were infrequently monitored with assessments of quantitative proteinuria or mineral metabolism disorder, even for patients with baseline kidney disease.

  20. 2003 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Illness and Injury Prevention Programs

    2007-05-23

    Annual Illness and Injury Surveillance Program report for 2003 for the Nevada Test Site. The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  1. Using confidence intervals for assessing reliability of real tests

    NARCIS (Netherlands)

    Oosterwijk, P.R.; van der Ark, L.A.; Sijtsma, K.

    2018-01-01

    Test authors report sample reliability values but rarely consider the sampling error and related confidence intervals. This study investigated the truth of this conjecture for 116 tests with 1,024 reliability estimates (105 pertaining to test batteries and 919 to tests measuring a single attribute)

  2. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  3. Parametric change point estimation, testing and confidence interval ...

    African Journals Online (AJOL)

    In many applications like finance, industry and medicine, it is important to consider that the model parameters may undergo changes at unknown moment in time. This paper deals with estimation, testing and confidence interval of a change point for a univariate variable which is assumed to be normally distributed. To detect ...

  4. Optimization of testing and maintenance intervals of standby units

    International Nuclear Information System (INIS)

    Vaurio, J.

    1996-01-01

    The time-dependent unavailability of periodically tested aging components is studied under various maintenance policies in which component renewal may or may not take place in tests or repairs. Analytical and numerical results are developed especially for the case that neither tests nor repairs nenew a component. The role of periodic preventive maintenance is analyzed in details, developing criteria and equations for economic optimization of periodic testing and maintenance intervals. The costs of these actions as well as the costs of repairs and accidents that may occur due to failures are taken into account. The roles of different cost and aging parameters are clearly visible in the results. Explicit optimum intervals are obtained in case of a generalized Weibull hazard rate. (orig.) (22 refs.)

  5. Confidence Intervals: From tests of statistical significance to confidence intervals, range hypotheses and substantial effects

    Directory of Open Access Journals (Sweden)

    Dominic Beaulieu-Prévost

    2006-03-01

    Full Text Available For the last 50 years of research in quantitative social sciences, the empirical evaluation of scientific hypotheses has been based on the rejection or not of the null hypothesis. However, more than 300 articles demonstrated that this method was problematic. In summary, null hypothesis testing (NHT is unfalsifiable, its results depend directly on sample size and the null hypothesis is both improbable and not plausible. Consequently, alternatives to NHT such as confidence intervals (CI and measures of effect size are starting to be used in scientific publications. The purpose of this article is, first, to provide the conceptual tools necessary to implement an approach based on confidence intervals, and second, to briefly demonstrate why such an approach is an interesting alternative to an approach based on NHT. As demonstrated in the article, the proposed CI approach avoids most problems related to a NHT approach and can often improve the scientific and contextual relevance of the statistical interpretations by testing range hypotheses instead of a point hypothesis and by defining the minimal value of a substantial effect. The main advantage of such a CI approach is that it replaces the notion of statistical power by an easily interpretable three-value logic (probable presence of a substantial effect, probable absence of a substantial effect and probabilistic undetermination. The demonstration includes a complete example.

  6. Respect versus Surveillance: Drug Testing Our Students

    Science.gov (United States)

    Brendtro, Larry K.; Martin, Gordon A., Jr.

    2006-01-01

    This launches a new periodic feature in Reclaiming Children and Youth. "Justice Alerts" examines current laws and policies against the twofold standards of solid science and moral values. This inaugural article explores the legal issues and political rhetoric surrounding random drug testing in schools and describes how science is being…

  7. Licensing experience of the evaluation of surveillance test for digital I and C systems important to safety

    International Nuclear Information System (INIS)

    Ji, S. H.; Kim, D. I.

    2010-01-01

    The introduction of digital systems in nuclear power plants becomes inevitable nowadays. This trend applies not only to the newly constructed plants but also to the operating plants which are to be upgraded. But the existing code and standards for I and C systems important to safety do not appropriately incorporate the characteristics of digital systems yet. This paper presents licensing experience of the evaluation of surveillance test for the Digital Plant Protection System (DPPS) of Ulchin Nuclear Power Plant unit 5 and 6. As a standard for surveillance test, IEEE Std 338-2006 is almost same as 1987 edition except the risk based guidance for the determination of test intervals. It does not incorporate the design features of digital system regarding the surveillance test method. But IEC 60671 published in 2007 strengthens the role of computer self supervision as an alternative to periodic surveillance testing. We have evaluated the change of surveillance test methodology for DPPS according to IEC 60671. We have reviewed the characteristics of self diagnostic programs, self test programs, their test coverage and the integrity of checking algorithms. And we have reviewed the failure mode and effect analysis of DPPS to verify the acceptability of new test methodology. In this paper, we discuss the major issues related to the surveillance test for digital systems important to safety. And we describe our approach and evaluation results for the change of test methodology for DPPS. (authors)

  8. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  9. Interval colon cancer in a Lynch syndrome patient under annual colonoscopic surveillance: a case for advanced imaging techniques?

    Directory of Open Access Journals (Sweden)

    Oxentenko Amy S

    2012-05-01

    Full Text Available Abstract Background Lynch syndrome confers increased risk for various malignancies, including colorectal cancer. Colonoscopic surveillance programs have led to reduced incidence of colorectal cancer and reduced mortality from colorectal cancer. Colonoscopy every 1–2 years beginning at age 20–25, or 10 years earlier than the first diagnosis of colorectal cancer in a family, with annual colonoscopy after age 40, is the recommended management for mutation carriers. Screening programs have reduced colon cancer mortality, but interval cancers may occur. Case presentation We describe a 48-year-old woman with Lynch syndrome who was found to have an adenoma with invasive colorectal cancer within one year after a normal colonoscopy. Conclusion Our patient illustrates two current concepts about Lynch syndrome: 1 adenomas are the cancer precursor and 2 such adenomas may be “aggressive,” in the sense that the adenoma progresses more readily and more rapidly to carcinoma in this setting compared to usual colorectal adenomas. Our patient’s resected tumor invaded only into submucosa and all lymph nodes were negative; in that sense, she represents a success for annual colonoscopic surveillance. Still, this case does raise the question of whether advanced imaging techniques are advisable for surveillance colonoscopy in these high-risk patients.

  10. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  11. Confidence Intervals for Laboratory Sonic Boom Annoyance Tests

    Science.gov (United States)

    Rathsam, Jonathan; Christian, Andrew

    2016-01-01

    Commercial supersonic flight is currently forbidden over land because sonic booms have historically caused unacceptable annoyance levels in overflown communities. NASA is providing data and expertise to noise regulators as they consider relaxing the ban for future quiet supersonic aircraft. One deliverable NASA will provide is a predictive model for indoor annoyance to aid in setting an acceptable quiet sonic boom threshold. A laboratory study was conducted to determine how indoor vibrations caused by sonic booms affect annoyance judgments. The test method required finding the point of subjective equality (PSE) between sonic boom signals that cause vibrations and signals not causing vibrations played at various amplitudes. This presentation focuses on a few statistical techniques for estimating the interval around the PSE. The techniques examined are the Delta Method, Parametric and Nonparametric Bootstrapping, and Bayesian Posterior Estimation.

  12. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  13. Transitioning from antenatal surveillance surveys to routine HIV testing: a turning point in the mother-to-child transmission prevention programme for HIV surveillance in Brazil.

    Science.gov (United States)

    Pereira, Gerson Fernando Mendes; Sabidó, Meritxell; Caruso, Alessandro; Benzaken, Adele Schwartz

    2017-07-05

    In Brazil, due to the rapid increase in programmes for the prevention of mother-to-child transmission (PMTCT), routine programme data are widely available. The objective of this study was to assess the utility of programmatic data to replace HIV surveillance based on the antenatal care (ANC) surveillance survey (SS). We analysed ANC SS data from 219 maternity service clinics. PMTCT variables were extracted from the ANC SS data collection form, which allowed us to capture and compare the ANC SS data and PMTCT HIV test results for each pregnant woman who completed the ANC SS. Both the PMTCT programme and the ANC SS tested for HIV using sequential ELISA and western blot for confirmation. We assessed the completeness (% missing) of the PMTC data included in the ANC SS. Of the 36,713 pregnant women who had ANC SS HIV tests performed, 30,588 also underwent PMTCT HIV testing. The HIV prevalence rate from routine PMTCT testing was 0.36%, compared to 0.38% from the ANC SS testing (relative difference -0.05%; absolute difference -0.02%). The relative difference in prevalence rates between pregnant women in northern Brazil and pregnant women central-west Brazil was -0.98 and 0.66, respectively. Of the 29,856 women who had HIV test results from both the PMTCT and ANC SS, the positive percent agreement of the PMTCT versus the surveillance test was 84.1% (95% confidence interval [CI]: 74.8-91.0), and the negative percent agreement was 99.9% (95% CI: 99.9-100.0). The PMTCT HIV testing uptake was 86.4%. The ANC SS HIV prevalence was 0.33% among PMTCT non-refusers and 0.59% among refusers, with a percent bias of -10.80% and a differential prevalence ratio of 0.56. Syphilis and HIV testing results were complete in 98% and 97.6% of PMTCT reports, respectively. The reported HIV status for the women at clinic entry was missing. Although there were consistent HIV prevalence estimates from the PMTCT data and the ANC SS, the overall positive percent agreement of 84.1% falls below the

  14. Occupational health surveillance: Pulmonary function testing in emergency responders

    Directory of Open Access Journals (Sweden)

    James D McCluskey

    2014-01-01

    Full Text Available Emergency responders may be exposed to a variety of fumes, gases, and particulates during the course of their job that can affect pulmonary function (PF and require the use of respiratory protection. This investigation used occupational health monitoring examination data to characterize PF in a population currently employed as emergency responders. PF tests for workers who required health examinations to ensure fitness for continued respirator use were compared to the National Health and Nutrition Examination Survey (NHANES III Raw Spirometry database to determine if decreased PF was associated with employment as an emergency responder. The results of this research indicated that the emergency responders experienced a modest, but statistically significant, increase in forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC mean values over the NHANES III population in both total and stratified analyses, including stratification by age, gender, height, and smoking history. Results are likely due to a combination of effectively controlled exposures in the workplace, and the healthy worker effect among long-term workers. PF testing required by the Occupational and Safety Health Administration (OSHA has substantial utility for conducting occupational surveillance at the population level. In this investigation, we were able to quickly evaluate if abnormal PF existed in an industrial sector known to have exposures that, when uncontrolled, can lead to PF impairment.

  15. Bayes Factor Approaches for Testing Interval Null Hypotheses

    NARCIS (Netherlands)

    Morey, Richard D.; Rouder, Jeffrey N.

    2011-01-01

    Psychological theories are statements of constraint. The role of hypothesis testing in psychology is to test whether specific theoretical constraints hold in data. Bayesian statistics is well suited to the task of finding supporting evidence for constraint, because it allows for comparing evidence

  16. Bayes Factor Approaches for Testing Interval Null Hypotheses

    Science.gov (United States)

    Morey, Richard D.; Rouder, Jeffrey N.

    2011-01-01

    Psychological theories are statements of constraint. The role of hypothesis testing in psychology is to test whether specific theoretical constraints hold in data. Bayesian statistics is well suited to the task of finding supporting evidence for constraint, because it allows for comparing evidence for 2 hypotheses against each another. One issue…

  17. The technology development for surveillance test of RPV materials 2

    International Nuclear Information System (INIS)

    Chang, Kee Ok; Lee, Sam Lai; Kim, Byoung Chul; Choi, Sun Pil; Choi, Kwen Jai

    1998-12-01

    Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of 2.4 x 10 1 9n/cm 2 (E≥1.0 MeV) in a typical pressurized water reactor environment at about 288 deg C. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen Noise(BN) amplitude, coercivity, maximum induction were measured for magnetic parameters, respectively. Results of mechanical property measurements showed an increase in yield and tensil strength, microvickers hardness 41J indexed RT NDT and a decrease in upper shelf energy irrespective of base and weld metals. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude, BN energy have dropped significantly but coercivity has increased rapidly after irradiation. For isothermally heat treated condition of irradiated specimen, BN energy has increased while Vickers microhardness has decreased. Results of BNE and Vickers microhardness are reversed to the results on irradiated condition. All these consistent changes in magnetic parameter and Vickers microhardness measurement, which are thought to be resulted from the interaction between irradiation-induced defects and dislocation, and magnetic domain, respectively, show a possibility that magnetic measurement may be used to the evaluation of material degradation and recovery due to neutron irradiation and heat treatment, respectively, if a relevant large database is prepared. (author). 49 refs., 7 tabs., 23 figs

  18. 2008 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-10-05

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  19. 2006 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2008-04-24

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of illness and injury surveillance activities that provide an early warning system to detect health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence, occupational injuries and illnesses, and disabilities and deaths among current workers.

  20. 2007 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-06-30

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  1. Simulation model estimates of test accuracy and predictive values for the Danish Salmonella surveillance program in dairy herds

    DEFF Research Database (Denmark)

    Warnick, L.D.; Nielsen, L.R.; Nielsen, Jens

    2006-01-01

    The Danish government and cattle industry instituted a Salmonella surveillance program in October 2002 to help reduce Salmonella enterica subsp. enterica serotype Dublin (S. Dublin) infections. All dairy herds are tested by measuring antibodies in bulk tank milk at 3-month intervals. The program...... is based on a well-established ELISA, but the overall test program accuracy and misclassification was not previously investigated. We developed a model to simulate repeated bulk tank milk antibody measurements for dairy herds conditional on true infection status. The distributions of bulk tank milk...

  2. Can we ease the financial burden of colonoscopy? Using real-time endoscopic assessment of polyp histology to predict surveillance intervals.

    Science.gov (United States)

    Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M

    2015-12-01

    Polyps identified at colonoscopy are predominantly diminutive (1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.

  3. Binomial confidence intervals for testing non-inferiority or superiority: a practitioner's dilemma.

    Science.gov (United States)

    Pradhan, Vivek; Evans, John C; Banerjee, Tathagata

    2016-08-01

    In testing for non-inferiority or superiority in a single arm study, the confidence interval of a single binomial proportion is frequently used. A number of such intervals are proposed in the literature and implemented in standard software packages. Unfortunately, use of different intervals leads to conflicting conclusions. Practitioners thus face a serious dilemma in deciding which one to depend on. Is there a way to resolve this dilemma? We address this question by investigating the performances of ten commonly used intervals of a single binomial proportion, in the light of two criteria, viz., coverage and expected length of the interval. © The Author(s) 2013.

  4. A Methodology for Evaluation of Inservice Test Intervals for Pumps and Motor Operated Valves

    International Nuclear Information System (INIS)

    McElhaney, K.L.

    1999-01-01

    The nuclear industry has begun efforts to reevaluate inservice tests (ISTs) for key components such as pumps and valves. At issue are two important questions--What kinds of tests provide the most meaningful information about component health, and what periodic test intervals are appropriate? In the past, requirements for component testing were prescribed by the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. The tests and test intervals specified in the Code were generic in nature and test intervals were relatively short. Operating experience has shown, however, that performance and safety improvements and cost savings could be realized by tailoring IST programs to similar components with comparable safety importance and service conditions. In many cases, test intervals may be lengthened, resulting in cost savings for utilities and their customers

  5. Results from an Interval Management (IM) Flight Test and Its Potential Benefit to Air Traffic Management Operations

    Science.gov (United States)

    Baxley, Brian; Swieringa, Kurt; Berckefeldt, Rick; Boyle, Dan

    2017-01-01

    NASA's first Air Traffic Management Technology Demonstration (ATD-1) subproject successfully completed a 19-day flight test of an Interval Management (IM) avionics prototype. The prototype was built based on IM standards, integrated into two test aircraft, and then flown in real-world conditions to determine if the goals of improving aircraft efficiency and airport throughput during high-density arrival operations could be met. The ATD-1 concept of operation integrates advanced arrival scheduling, controller decision support tools, and the IM avionics to enable multiple time-based arrival streams into a high-density terminal airspace. IM contributes by calculating airspeeds that enable an aircraft to achieve a spacing interval behind the preceding aircraft. The IM avionics uses its data (route of flight, position, etc.) and Automatic Dependent Surveillance-Broadcast (ADS-B) state data from the Target aircraft to calculate this airspeed. The flight test demonstrated that the IM avionics prototype met the spacing accuracy design goal for three of the four IM operation types tested. The primary issue requiring attention for future IM work is the high rate of IM speed commands and speed reversals. In total, during this flight test, the IM avionics prototype showed significant promise in contributing to the goals of improving aircraft efficiency and airport throughput.

  6. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  7. Irradiation surveillant test of High Flux Engineering Test Reactor (HFETR) pressure vessel

    International Nuclear Information System (INIS)

    Gao Weisen; Cui Yonghai

    1991-08-01

    The result of irradiation surveillant test of HFETR pressure vessel is presented. It shows that after 3.3 x 10 20 n/cm 2 irradiation the irradiation brittleness effect in welding seam (ws) is smaller than in heat-affected zone (HAZ), and the irradiation brittleness effect in HAZ is smaller than in base material (BM). From the view point of irradiation brittleness, under present operation conditions of the HFETR, the safety margin of plasticity and toughness in the WS, BM and HAZ is sufficient within the design life of the reactor

  8. The relationship between the interval shuttle run test and maximal oxygen uptake in soccer players

    NARCIS (Netherlands)

    Lemmink, KAPM; Visscher, C

    2003-01-01

    The aim of this study was to determine the relationship between the interval shuttle run test (ISRT) and maximal oxygen uptake (VO2max) in soccer players. The ISRT was developed to measure interval endurance capacity. During the ISRT, subjects alternately run for 30 sec and walk for 15 sec with

  9. Impact of pap test compliance and cervical cancer screening intervals on human papillomavirus vaccine acceptance.

    Science.gov (United States)

    Ferris, Daron G; Waller, Jennifer; Dickinson, Ashley; McCracken, Courtney; Goebel, Angela

    2012-01-01

    The objective of this study was to determine the impact of Pap test compliance and cervical cancer screening intervals on human papillomavirus (HPV) vaccination acceptance. A convenience sample of 499 women 21 to 65 years old completed a 37-question survey in Augusta and Savannah, GA. The survey assessed their knowledge about HPV, cervical cancer, and the HPV vaccine. The questionnaire also determined their Pap test compliance and how longer Pap test intervals would influence their willingness to receive the HPV vaccine. Differences between categorical variables and knowledge scores were examined using χ test and unequal-variance t tests, respectively. Pap test-noncompliant women were more likely to get the HPV vaccine if they only needed a Pap test every 10 years compared with Pap test-compliant women (27.6% vs 14.6%, p = .02). A greater number (83.5%) of Pap test-noncompliant women preferred the HPV vaccine plus every 10-year Pap test option compared with Pap test-compliant women (31.3%, p Pap testing. Women are receptive to getting the HPV vaccine in exchange for longer cervical cancer screening intervals. Moreover, Pap test-noncompliant women are more likely to get the HPV vaccine if Pap testing was needed less frequently. Increasing the Pap testing interval may be an excellent method to improving HPV vaccine acceptance in women at highest risk for cervical cancer.

  10. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  11. Solar Alpha Rotary Joint (SARJ) Lubrication Interval Test and Evaluation (LITE). Post-Test Grease Analysis

    Science.gov (United States)

    Golden, Johnny L.; Martinez, James E.; Devivar, Rodrigo V.

    2015-01-01

    The Solar Alpha Rotary Joint (SARJ) is a mechanism of the International Space Station (ISS) that orients the solar power generating arrays toward the sun as the ISS orbits our planet. The orientation with the sun must be maintained to fully charge the ISS batteries and maintain all the other ISS electrical systems operating properly. In 2007, just a few months after full deployment, the starboard SARJ developed anomalies that warranted a full investigation including ISS Extravehicular Activity (EVA). The EVA uncovered unexpected debris that was due to degradation of a nitride layer on the SARJ bearing race. ISS personnel identified the failure root-cause and applied an aerospace grease to lubricate the area associated with the anomaly. The corrective action allowed the starboard SARJ to continue operating within the specified engineering parameters. The SARJ LITE (Lubrication Interval Test and Evaluation) program was initiated by NASA, Lockheed Martin, and Boeing to simulate the operation of the ISS SARJ for an extended time. The hardware was designed to test and evaluate the exact material components used aboard the ISS SARJ, but in a controlled area where engineers could continuously monitor the performance. After running the SARJ LITE test for an equivalent of 36+ years of continuous use, the test was opened to evaluate the metallography and lubrication. We have sampled the SARJ LITE rollers and plate to fully assess the grease used for lubrication. Chemical and thermal analysis of these samples has generated information that has allowed us to assess the location, migration, and current condition of the grease. The collective information will be key toward understanding and circumventing any performance deviations involving the ISS SARJ in the years to come.

  12. Incidence of interval cancers in faecal immunochemical test colorectal screening programmes in Italy.

    Science.gov (United States)

    Giorgi Rossi, Paolo; Carretta, Elisa; Mangone, Lucia; Baracco, Susanna; Serraino, Diego; Zorzi, Manuel

    2018-03-01

    Objective In Italy, colorectal screening programmes using the faecal immunochemical test from ages 50 to 69 every two years have been in place since 2005. We aimed to measure the incidence of interval cancers in the two years after a negative faecal immunochemical test, and compare this with the pre-screening incidence of colorectal cancer. Methods Using data on colorectal cancers diagnosed in Italy from 2000 to 2008 collected by cancer registries in areas with active screening programmes, we identified cases that occurred within 24 months of negative screening tests. We used the number of tests with a negative result as a denominator, grouped by age and sex. Proportional incidence was calculated for the first and second year after screening. Results Among 579,176 and 226,738 persons with negative test results followed up at 12 and 24 months, respectively, we identified 100 interval cancers in the first year and 70 in the second year. The proportional incidence was 13% (95% confidence interval 10-15) and 23% (95% confidence interval 18-25), respectively. The estimate for the two-year incidence is 18%, which was slightly higher in females (22%; 95% confidence interval 17-26), and for proximal colon (22%; 95% confidence interval 16-28). Conclusion The incidence of interval cancers in the two years after a negative faecal immunochemical test in routine population-based colorectal cancer screening was less than one-fifth of the expected incidence. This is direct evidence that the faecal immunochemical test-based screening programme protocol has high sensitivity for cancers that will become symptomatic.

  13. Conditional dependence between tests affects the diagnosis and surveillance of animal diseases

    DEFF Research Database (Denmark)

    Gardner, I.A.; Stryhn, Henrik; Lind, Peter

    2000-01-01

    Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel te...... for toxoplasmosis and brucellosis in swine, and Johne's disease in cattle to illustrate calculation methods and to indicate the likely magnitude of the dependence between serologic tests used for diagnosis and surveillance of animal diseases....

  14. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    Science.gov (United States)

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  15. The interval shuttle run test for intermittent sport players : evaluation of reliability

    NARCIS (Netherlands)

    Lemmink, K.A.P.M.; Visscher, C.; Lambert, M.I.; Lamberts, R.P.

    2004-01-01

    The reliability of the interval shuttle run test (ISRT) as a submaximal and maximal field test to measure intermittent endurance capacity was examined. During the ISRT, participants alternately run for 30 seconds and walk for 15 seconds. The running speed is increased from 10 km.h(-1) every 90

  16. Use of CA-125 Tests and CT Scans for Surveillance in Ovarian Cancer

    Science.gov (United States)

    Esselen, Katharine M.; Cronin, Angel M.; Bixel, Kristin; Bookman, Michael A.; Burger, Robert A.; Cohn, David E.; Cristea, Mihaela; Griggs, Jennifer J.; Levenback, Charles F.; Mantia-Smaldone, Gina; Meyer, Larissa A.; Matulonis, Ursula A.; Niland, Joyce C.; Sun, Charlotte; O’Malley, David M.; Wright, Alexi A.

    2016-01-01

    Importance A 2009 randomized clinical trial (RCT) demonstrated that using CA-125 tests for routine surveillance in ovarian cancer increases chemotherapy use and decreases patients’ quality of life without improving survival, compared with clinical observation. The Society of Gynecologic Oncology guidelines categorize CA-125 testing as “optional” and discourage the use of radiographic imaging for routine surveillance. To date, few studies have examined their use in clinical practice. Objective To examine the use of CA-125 tests and CT scans in clinical practice before and after the 2009 RCT and estimate the economic impact of surveillance testing. Design Prospective cohort of women diagnosed with ovarian cancer between 2004-2011 and followed through 2012. Setting Six National Cancer Institute-Designated Cancer Centers. Participants 1,241 women with ovarian cancer in clinical remission after completion of primary cytoreductive surgery and chemotherapy. Main Outcome Measures Use of CA-125 tests and CT scans before and after 2009 (n=1,241). Secondary outcomes included: the time from CA-125 doubling to retreatment among women who experienced a rise in CA-125 (n=511) before and after 2009, and the costs associated with surveillance testing using 2016 Medicare reimbursement rates. Results Use of CA-125 testing and CT scans was very similar over the study period. During 12 months of surveillance, the cumulative incidence of 3 or more CA-125 tests was 86% in 2004-2009 versus 91% in 2010-2012 (P=.95), and the cumulative incidence of more than 1 CT scan was 81% (2004-2009) versus 78% (2010-2012) (P=.50). Among women who experienced a CA-125 doubling (n=511), there was no significant difference in the time to retreatment with chemotherapy before and after 2009 (median: 2.8 months vs. 3.5 months, P=.40). Over a 12-month period, there were a mean of 4.6 CA-125 tests and 1.7 CT scans per patient, resulting in a United States population surveillance cost estimate of $1

  17. Mountaintop Surveillance Sensor Test Integration Center Facility, Kauai, Hawaii

    National Research Council Canada - National Science Library

    Craven, Tom

    2000-01-01

    .... All sites are located on the Island of Kauai, Hawaii. The tower originally installed and removed as part of the Mountaintop Sensor Integration and Test program would be reinstalled at PMRF-Kokee...

  18. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  19. Environmental surveillance report for the Nevada Test Site (January 1980-December 1980)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1981-01-01

    Results are presented for the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1980 through December 1980. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  20. Environmental-surveillance report for the Nevada Test Site (January 1982 through December 1982)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1983-06-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted from January 1982 through December 1982. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG's) is established

  1. Integration of HIV testing in tuberculosis drug resistance surveillance in Kazakhstan and Kenya

    NARCIS (Netherlands)

    Klinkenberg, E.; van den Hof, S.; Tursynbayeva, A.; Kipruto, H.; Wahogo, J.; Pak, S.; Kutwa, A.; L'Herminez, R.

    2012-01-01

    In Kenya and Kazakhstan, integration of human immunodeficiency virus (HIV) testing results into the routine surveillance of multidrug-resistant tuberculosis (MDR-TB) proved feasible and useful. The integration process improved overall data quality and data validation capacity, and integrated data

  2. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  3. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance

    NARCIS (Netherlands)

    Murphy, S.C.; Hermsen, C.C.; Douglas, A.D.; Edwards, N.J.; Petersen, I.; Fahle, G.A.; Adams, M.; Berry, A.A.; Billman, Z.P.; Gilbert, S.C.; Laurens, M.B.; Leroy, O.; Lyke, K.E.; Plowe, C.V.; Seilie, A.M.; Strauss, K.A.; Teelen, K.; Hill, A.V.; Sauerwein, R.W.

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal

  4. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  5. Environmental surveillance report for the Nevada Test Site (January 1981 through December 1981)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1982-05-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1981 through December 1981. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  6. Environmental surveillance report for the Nevada Test Site, January 1983 through December 1983

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1984-04-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted from January 1983 through December 1983. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG's) is established. 20 references, 15 figures, 22 tables

  7. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  9. Automated reactivity anomaly surveillance in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.; Honeyman, D.J.; Shook, A.T.; Krohn, C.N.

    1985-01-01

    The automated technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and, thus, provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state

  10. Comparative value of noninvasive testing for diagnosis and surveillance of deep vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Comerota, A.J.; Katz, M.L.; Grossi, R.J.; White, J.V.; Czeredarczuk, M.; Bowman, G.; DeSai, S.; Vujic, I.

    1988-01-01

    This is a prospective analysis of 351 patients in two distinct groups undergoing ascending phlebography, impedance plethysmography (IPG), and/or phleborheography (PRG) within the same 24-hour period. One hundred twenty patients also had a /sup 125/I-fibrinogen uptake test (RFUT). The two patient groups consisted of the following: those patients evaluated because of suspicion of deep vein thrombosis (DVT) (diagnostic) and those patients at high risk for postoperative DVT (total joint replacement) who had routine noninvasive testing and ascending phlebography (surveillance). The overall sensitivities for IPG and PRG were significantly better in the diagnosis group (71% (69 of 97 patients) and 78% (82 of 105), respectively) compared with the surveillance group (20% (14 of 71) and 27% (17 of 63), respectively) (p less than 0.0001). The sensitivities for IPG and PRG detecting proximal (A/K) thrombi was 83% (68 of 82 patients) and 92% (79 of 86) in the diagnosis group compared with 32% (11 of 34) and 33% (9 of 27) in the surveillance group (p less than 0.0001). Although there was no difference in overall incidence of DVT between the diagnosis group (56%, 118 of 212 patients) and the surveillance group (55%, 76 of 139), the results can be explained by the difference in A/K thrombi (84% (99 of 118) and 47% (36 of 76)) (p less than 0.001) and occlusive A/K thrombi (84% (58 of 69) and 23% (7 of 31)) (p less than 0.0001), respectively. Of the patients with A/K thrombi, 97% (67 of 69) in the diagnosis group had hemodynamically detectable thrombi compared with only 48% (12 of 25) in the surveillance group (p less than 0.001). Combining the RFUT with the noninvasive studies for surveillance significantly improved the sensitivity for both A/K and distal thrombi.

  11. Comparative value of noninvasive testing for diagnosis and surveillance of deep vein thrombosis

    International Nuclear Information System (INIS)

    Comerota, A.J.; Katz, M.L.; Grossi, R.J.; White, J.V.; Czeredarczuk, M.; Bowman, G.; DeSai, S.; Vujic, I.

    1988-01-01

    This is a prospective analysis of 351 patients in two distinct groups undergoing ascending phlebography, impedance plethysmography (IPG), and/or phleborheography (PRG) within the same 24-hour period. One hundred twenty patients also had a 125 I-fibrinogen uptake test (RFUT). The two patient groups consisted of the following: those patients evaluated because of suspicion of deep vein thrombosis (DVT) (diagnostic) and those patients at high risk for postoperative DVT (total joint replacement) who had routine noninvasive testing and ascending phlebography (surveillance). The overall sensitivities for IPG and PRG were significantly better in the diagnosis group (71% [69 of 97 patients] and 78% [82 of 105], respectively) compared with the surveillance group (20% [14 of 71] and 27% [17 of 63], respectively) (p less than 0.0001). The sensitivities for IPG and PRG detecting proximal (A/K) thrombi was 83% (68 of 82 patients) and 92% (79 of 86) in the diagnosis group compared with 32% (11 of 34) and 33% (9 of 27) in the surveillance group (p less than 0.0001). Although there was no difference in overall incidence of DVT between the diagnosis group (56%, 118 of 212 patients) and the surveillance group (55%, 76 of 139), the results can be explained by the difference in A/K thrombi (84% [99 of 118] and 47% [36 of 76]) (p less than 0.001) and occlusive A/K thrombi (84% [58 of 69] and 23% [7 of 31]) (p less than 0.0001), respectively. Of the patients with A/K thrombi, 97% (67 of 69) in the diagnosis group had hemodynamically detectable thrombi compared with only 48% (12 of 25) in the surveillance group (p less than 0.001). Combining the RFUT with the noninvasive studies for surveillance significantly improved the sensitivity for both A/K and distal thrombi

  12. Hierarchical models in ecology: confidence intervals, hypothesis testing, and model selection using data cloning.

    Science.gov (United States)

    Ponciano, José Miguel; Taper, Mark L; Dennis, Brian; Lele, Subhash R

    2009-02-01

    Hierarchical statistical models are increasingly being used to describe complex ecological processes. The data cloning (DC) method is a new general technique that uses Markov chain Monte Carlo (MCMC) algorithms to compute maximum likelihood (ML) estimates along with their asymptotic variance estimates for hierarchical models. Despite its generality, the method has two inferential limitations. First, it only provides Wald-type confidence intervals, known to be inaccurate in small samples. Second, it only yields ML parameter estimates, but not the maximized likelihood values used for profile likelihood intervals, likelihood ratio hypothesis tests, and information-theoretic model selection. Here we describe how to overcome these inferential limitations with a computationally efficient method for calculating likelihood ratios via data cloning. The ability to calculate likelihood ratios allows one to do hypothesis tests, construct accurate confidence intervals and undertake information-based model selection with hierarchical models in a frequentist context. To demonstrate the use of these tools with complex ecological models, we reanalyze part of Gause's classic Paramecium data with state-space population models containing both environmental noise and sampling error. The analysis results include improved confidence intervals for parameters, a hypothesis test of laboratory replication, and a comparison of the Beverton-Holt and the Ricker growth forms based on a model selection index.

  13. Surveillance tests for light-water cooled nuclear power reactor vessels in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong-Sun; Ahn, Sang-Bok; Park, Dae-Gyu; Jung, Yang-Hong; Yoo, Byung-Ok; Oh, Wan-Ho; Baik, Seung-Je; Koo, Dae-Seo; Lee, Key-Soon

    1999-01-01

    The surveillance tests for light-water cooled nuclear power reactor vessels were established to monitor the radiation-induced changes in the mechanical properties of ferritic materials in the beltline according to US NRC 10 CFR 50 App. G, US NRC RG1.99-rev.2, ASTM E185-82 and E185-94 in Irradiated Materials Examination Facility(IMEF). The surveillance capsule was transported from NPPs pool sites to KAERI IMEF by using a shipping cask. The capsule was cut and dismantled by capsule cutting machine and milling machine in M2 hot cell. Charpy tests and tension tests were performed in M5a and M5b hot cells respectively. Especially the EPMA located at hot lab was used to analyze the Ni and Cu wt% composition of base metal and weld for predicting the adjusted reference temperature(ART). The established process and test results were summarized in this paper. (author)

  14. Long-term maintenance of immediate or delayed extinction is determined by the extinction-test interval

    OpenAIRE

    Johnson, Justin S.; Escobar, Martha; Kimble, Whitney L.

    2010-01-01

    Short acquisition-extinction intervals (immediate extinction) can lead to either more or less spontaneous recovery than long acquisition-extinction intervals (delayed extinction). Using rat subjects, we observed less spontaneous recovery following immediate than delayed extinction (Experiment 1). However, this was the case only if a relatively long extinction-test interval was used; a relatively short extinction-test interval yielded the opposite result (Experiment 2). Previous data appear co...

  15. Assessing Conformance with Benford's Law: Goodness-Of-Fit Tests and Simultaneous Confidence Intervals.

    Directory of Open Access Journals (Sweden)

    M Lesperance

    Full Text Available Benford's Law is a probability distribution for the first significant digits of numbers, for example, the first significant digits of the numbers 871 and 0.22 are 8 and 2 respectively. The law is particularly remarkable because many types of data are considered to be consistent with Benford's Law and scientists and investigators have applied it in diverse areas, for example, diagnostic tests for mathematical models in Biology, Genomics, Neuroscience, image analysis and fraud detection. In this article we present and compare statistically sound methods for assessing conformance of data with Benford's Law, including discrete versions of Cramér-von Mises (CvM statistical tests and simultaneous confidence intervals. We demonstrate that the common use of many binomial confidence intervals leads to rejection of Benford too often for truly Benford data. Based on our investigation, we recommend that the CvM statistic Ud(2, Pearson's chi-square statistic and 100(1 - α% Goodman's simultaneous confidence intervals be computed when assessing conformance with Benford's Law. Visual inspection of the data with simultaneous confidence intervals is useful for understanding departures from Benford and the influence of sample size.

  16. A better confidence interval for the sensitivity at a fixed level of specificity for diagnostic tests with continuous endpoints.

    Science.gov (United States)

    Shan, Guogen

    2017-02-01

    For a diagnostic test with continuous measurement, it is often important to construct confidence intervals for the sensitivity at a fixed level of specificity. Bootstrap-based confidence intervals were shown to have good performance as compared to others, and the one by Zhou and Qin (2005) was recommended as the best existing confidence interval, named the BTII interval. We propose two new confidence intervals based on the profile variance method and conduct extensive simulation studies to compare the proposed intervals and the BTII intervals under a wide range of conditions. An example from a medical study on severe head trauma is used to illustrate application of the new intervals. The new proposed intervals generally have better performance than the BTII interval.

  17. Tests and Confidence Intervals for an Extended Variance Component Using the Modified Likelihood Ratio Statistic

    DEFF Research Database (Denmark)

    Christensen, Ole Fredslund; Frydenberg, Morten; Jensen, Jens Ledet

    2005-01-01

    The large deviation modified likelihood ratio statistic is studied for testing a variance component equal to a specified value. Formulas are presented in the general balanced case, whereas in the unbalanced case only the one-way random effects model is studied. Simulation studies are presented......, showing that the normal approximation to the large deviation modified likelihood ratio statistic gives confidence intervals for variance components with coverage probabilities very close to the nominal confidence coefficient....

  18. [Changes of QT interval during graded exercise test in healthy adolescents aged 11-15 years].

    Science.gov (United States)

    Makarov, L M; Balykova, L A; Gorbunova, I A; Komoliatova, V N

    2012-01-01

    Aim of the study was determination of physiological limits of QT-intervals and its derivative values in healthy children and adolescents during graded exercise tests. We examined 100 healthy boys and girls aged 11-15 years (mean age 13.4+/-2.1 years) and performed electrocardiography at rest and standard veloergometry (VEM) in all of them. We analyzed corrected intervals according to Bazett (QTc=QT/RR) and Fredericia (FQTc/3RR) formulas. Hysteresis QTc was calculated as difference between QTc durations during recovery and exercise at same heart rate (HR) Baseline HR before VEM exceeded rhythm on resting electrocardiogram by 5-15 bpm (84+/-8 vs 70+/-6, respectively, p<0.05) Increase of HR at exercise (mean 172+/-11 bpm) was similar in both sexes. QT interval decreased by 7-10% (18-31 ms) per each 25 w (p<0.05). Values obtained at determination of FQTc we found values 26-52 ms lower than those calculated by the Bazett formula in the process of whole test. Determination of FQTc compared with calculation by Bazett formula revealed more pronounced (10% from baseline level) shortening of FQT at peak exercise. QT calculated by the Bazett formula at 100 w did not differ from baseline level with tendency to higher level. Corrected QT according to the most often used Bazett formula was maximal at the first stage of exercise (25 w) and did not exceed 450 ms in boys and 460ms in girls. Maximal QTc lengthening in the process of test did not exceed 50 ms in any of the examined persons. Hysteresis of QTc interval was equal to 21+/-6 (15-25) ms. The conclusion was made that algorithm of assessment of QT interval changes during exercise test should include initial values of QTc calculated according to the Bazett formula, maximal QTc value, level of exercise at which it was registered, maximal increase of QTc during exercise, and QTc interval hysteresis.

  19. A Methodology for Evaluation of Inservice Test Intervals for Pumps and Motor-Operated Valves

    International Nuclear Information System (INIS)

    Cox, D.F.; Haynes, H.D.; McElhaney, K.L.; Otaduy, P.J.; Staunton, R.H.; Vesely, W.E.

    1999-01-01

    Recent nuclear industry reevaluation of component inservice testing (IST) requirements is resulting in requests for IST interval extensions and changes to traditional IST programs. To evaluate these requests, long-term component performance and the methods for mitigating degradation need to be understood. Determining the appropriate IST intervals, along with component testing, monitoring, trending, and maintenance effects, has become necessary. This study provides guidelines to support the evaluation of IST intervals for pumps and motor-operated valves (MOVs). It presents specific engineering information pertinent to the performance and monitoring/testing of pumps and MOVs, provides an analytical methodology for assessing the bounding effects of aging on component margin behavior, and identifies basic elements of an overall program to help ensure component operability. Guidance for assessing probabilistic methods and the risk importance and safety consequences of the performance of pumps and MOVs has not been specifically included within the scope of this report, but these elements may be included in licensee change requests

  20. Use of CA-125 Tests and Computed Tomographic Scans for Surveillance in Ovarian Cancer.

    Science.gov (United States)

    Esselen, Katharine M; Cronin, Angel M; Bixel, Kristin; Bookman, Michael A; Burger, Robert A; Cohn, David E; Cristea, Mihaela; Griggs, Jennifer J; Levenback, Charles F; Mantia-Smaldone, Gina; Meyer, Larissa A; Matulonis, Ursula A; Niland, Joyce C; Sun, Charlotte; O'Malley, David M; Wright, Alexi A

    2016-11-01

    A 2009 randomized clinical trial demonstrated that using cancer antigen 125 (CA-125) tests for routine surveillance in ovarian cancer increases the use of chemotherapy and decreases patients' quality of life without improving survival, compared with clinical observation. The Society of Gynecologic Oncology guidelines categorize CA-125 testing as optional and discourage the use of radiographic imaging for routine surveillance. To date, few studies have examined the use of CA-125 tests in clinical practice. To examine the use of CA-125 tests and computed tomographic (CT) scans in clinical practice before and after the 2009 randomized clinical trial and to estimate the economic effect of surveillance testing. A prospective cohort of 1241 women with ovarian cancer in clinical remission after completion of primary cytoreductive surgery and chemotherapy at 6 National Cancer Institute-designated cancer centers between January 1, 2004, and December 31, 2011, was followed up through December 31, 2012, to study the use of CA-125 tests and CT scans before and after 2009. Data analysis was conducted from April 9, 2014, to March 28, 2016. The use of CA-125 tests and CT scans before and after 2009. Secondary outcomes included the time from CA-125 markers doubling to retreatment among women who experienced a rise in CA-125 markers before and after 2009, and the costs associated with surveillance testing using 2015 Medicare reimbursement rates. Among 1241 women (mean [SD] age 59 [12] years; 1112 white [89.6%]), the use of CA-125 testing and CT scans was similar during the study period. During 12 months of surveillance, the cumulative incidence of patients undergoing 3 or more CA-125 tests was 86% in 2004-2009 vs 91% in 2010-2012 (P = .95), and the cumulative incidence of patients undergoing more than 1 CT scan was 81% in 2004-2009 vs 78% in 2010-2012 (P = .50). Among women whose CA-125 markers doubled (n = 511), there was no significant difference in the time to

  1. Application of advanced irradiation analysis methods to light water reactor pressure vessel test and surveillance programs

    International Nuclear Information System (INIS)

    Odette, R.; Dudey, N.; McElroy, W.; Wullaert, R.; Fabry, A.

    1977-01-01

    Inaccurate characterization and inappropriate application of neutron irradiation exposure variables contribute a substantial amount of uncertainty to embrittlement analysis of light water reactor pressure vessels. Damage analysis involves characterization of the irradiation environment (dosimetry), correlation of test and surveillance metallurgical and dosimetry data, and projection of such data to service conditions. Errors in available test and surveillance dosimetry data are estimated to contribute a factor of approximately 2 to the data scatter. Non-physical (empirical) correlation procedures and the need to extrapolate to the vessel may add further error. Substantial reductions in these uncertainties in future programs can be obtained from a more complete application of available damage analysis tools which have been developed for the fast reactor program. An approach to reducing embrittlement analysis errors is described, and specific examples of potential applications are given. The approach is based on damage analysis techniques validated and calibrated in benchmark environments

  2. Test Statistics and Confidence Intervals to Establish Noninferiority between Treatments with Ordinal Categorical Data.

    Science.gov (United States)

    Zhang, Fanghong; Miyaoka, Etsuo; Huang, Fuping; Tanaka, Yutaka

    2015-01-01

    The problem for establishing noninferiority is discussed between a new treatment and a standard (control) treatment with ordinal categorical data. A measure of treatment effect is used and a method of specifying noninferiority margin for the measure is provided. Two Z-type test statistics are proposed where the estimation of variance is constructed under the shifted null hypothesis using U-statistics. Furthermore, the confidence interval and the sample size formula are given based on the proposed test statistics. The proposed procedure is applied to a dataset from a clinical trial. A simulation study is conducted to compare the performance of the proposed test statistics with that of the existing ones, and the results show that the proposed test statistics are better in terms of the deviation from nominal level and the power.

  3. Reducing the width of confidence intervals for the difference between two population means by inverting adaptive tests.

    Science.gov (United States)

    O'Gorman, Thomas W

    2018-05-01

    In the last decade, it has been shown that an adaptive testing method could be used, along with the Robbins-Monro search procedure, to obtain confidence intervals that are often narrower than traditional confidence intervals. However, these confidence interval limits require a great deal of computation and some familiarity with stochastic search methods. We propose a method for estimating the limits of confidence intervals that uses only a few tests of significance. We compare these limits to those obtained by a lengthy Robbins-Monro stochastic search and find that the proposed method is nearly as accurate as the Robbins-Monro search. Adaptive confidence intervals that are produced by the proposed method are often narrower than traditional confidence intervals when the distributions are long-tailed, skewed, or bimodal. Moreover, the proposed method of estimating confidence interval limits is easy to understand, because it is based solely on the p-values from a few tests of significance.

  4. Integrity assessment of TAPS reactor pressure vessel at extended EOL using surveillance test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah, Priti Kotak

    2008-05-01

    Integrity assessment of pressure vessels of nuclear reactors (RPV) primarily concentrates on the prevention of brittle failure and conditions are defined under which brittle failure can be excluded. Accordingly, two approaches based on Transition Temperature Concept and Fracture Mechanics Concept were adopted using the impact test results of three credible surveillance data sets obtained from the surveillance specimens of Tarapur Atomic Power Station. RT NDT data towards end of life (EOL) were estimated from the impact test results in accordance with the procedures of USNRC Regulatory Guide 1.99, Rev. 2 and were used as primary input for assessment of the vessel integrity. SA302B (nickel modified) steel cladded with stainless steel is used as the pressure vessel material for the two 210 MWe boiling water reactors of the Tarapur Atomic Power Station (TAPS). The reactors were commissioned during the year 1969. The chemical compositions of SA302B (modified) steel used in fabricating the vessel and the specified tensile property and the Charpy impact property requirements of the steel broadly meet ASME specified requirements. Therefore, the pressure temperature limit curves prescribed by General Electric (G.E.) were compared with those as obtained using procedures of ASME Section XII, Appendix G. The tensile and the Charpy impact properties at 60 EFPY of vessel operation as derived from the surveillance specimens even fulfilled the specified requirements for the virgin material of ASME. Integrity assessment carried out using the two approaches indicated the safety of the vessel for continued operation up to 60 EFPY. (author)

  5. Managing genetic tests, surveillance, and preventive medicine under a public health insurance system.

    Science.gov (United States)

    Filipova-Neumann, Lilia; Hoy, Michael

    2014-03-01

    There is a prospect in the medium to long term future of substantial advancements in the understanding of the relationship between disease and genetics. We consider the implications of increased information from genetic tests about predisposition to diseases from the perspective of managing health care provision under a public health insurance scheme. In particular, we consider how such information may potentially improve the targeting of medical surveillance (or prevention) activities to improve the chances of early detection of disease onset. We show that the moral hazard implications inherent in surveillance and prevention decisions that are chosen to be privately rather than socially optimal may be exacerbated by increased information about person-specific predisposition to disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

    Science.gov (United States)

    Shi, Xiangyun; Kuang, Yang; Makroglou, Athena; Mokshagundam, Sriprakash; Li, Jiaxu

    2017-11-01

    Type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index.

  7. Prognostic value of QTc interval dispersion changes during exercise testing in hypertensive men

    Directory of Open Access Journals (Sweden)

    Đorđević Dragan

    2008-01-01

    Full Text Available INTRODUCTION The prognostic significance of QTc dispersion changes during exercise testing (ET in patients with left ventricular hypertrophy is not clear. OBJECTIVE The aim was to study the dynamics of QTc interval dispersion (QTcd in patients (pts with left ventricular hypertrophy (LVH during the exercise testing and its prognostic significance. METHOD In the study we included 55 men (aged 53 years with hypertensive left ventricular hypertrophy and a negative ET (LVH group, 20 men (aged 58 years with a positive ET and 20 healthy men (aged 55 years. There was no statistically significant difference in the left ventricular mass index (LVMI between LVH group and ILVH group (160.9±14.9 g/m2 and 152.8±22.7 g/m2. The first ECG was done before the ET and the second one was done during the first minute of recovery, with calculation of QTc dispersion. The patients were followed during five years for new cardiovascular events. RESULTS During the ET, the QTcd significantly increased in LVH group (56.8±18.0 - 76.7±22.6 ms; p<0.001. A statistically significant correlation was found between the amount of ST segment depression at the end of ET and QTc dispersion at the beginning and at the end of ET (r=0.673 and r=0.698; p<0.01. The QTc dispersion was increased in 35 (63.6% patients and decreased in 20 (36.4% patients during the ET. Three patients (5.4% in the first group had adverse cardiovascular events during the five-year follow-up. A multiple stepwise regression model was formed by including age, LVMI, QTc interval, QTc dispersion and change of QTc dispersion during the ET. There was no prognostic significance of QTc interval and QTc dispersion during five-year follow-up in regard to adverse cardiovascular events, but prognostic value was found for LVMI (coefficient β=0.480; p<0.001. CONCLUSION The increase of QTc interval dispersion is common in men with positive ET for myocardial ischemia and there is a correlation between QTc dispersion and

  8. Trimester specific reference intervals for thyroid function tests in normal Indian pregnant women

    Science.gov (United States)

    Sekhri, Tarun; Juhi, Juhi Agarwal; Wilfred, Reena; Kanwar, Ratnesh S.; Sethi, Jyoti; Bhadra, Kuntal; Nair, Sirimavo; Singh, Satveer

    2016-01-01

    Context: Accurate assessment of thyroid function during pregnancy is critical, for initiation of thyroid hormone therapy, as well as for adjustment of thyroid hormone dose in hypothyroid cases. Aims: We evaluated pregnant women who had no past history of thyroid disorders and studied their thyroid function in each trimester. Settings and Design: 86 normal pregnant women in the first trimester of pregnancy were selected for setting reference intervals. All were healthy, euthyroid and negative for thyroid peroxidase antibody (TPOAb). These women were serially followed throughout pregnancy. 124 normal nonpregnant subjects were selected for comparison. Material and methods: Thyrotropin (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and anti-TPO were measured using Roche Elecsys 1010 analyzer. Urinary iodine content was determined by simple microplate method. The 2.5th and 97.5th percentiles were calculated as the reference intervals for thyroid hormone levels during each trimester. Statistical Analysis: SPSS (version 14.0, SPSS Inc., Chicago, IL, USA) was used for data processing and analysis. Results: The reference intervals for the first, second and third trimesters for the following parameters: TSH 0.09-6.65, 0.51-6.66, 0.91-4.86 µIU/mL, FT4 9.81-18.53, 8.52-19.43, 7.39-18.28 pM/L and FT3 3.1-6.35, 2.39-5.12, 2.57-5.68 pM/L respectively. Thyroid hormone concentrations significantly differed during pregnancy at different stages of gestation. The pregnant women in the study had median urinary iodine concentration of 150-200 µg/l during each trimester. Conclusions: The trimester-specific reference intervals for thyroid tests during pregnancy have been established for pregnant Indian women serially followed during pregnancy using 2.5th and 97.5th percentiles. PMID:26904477

  9. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    Full Text Available Abstract Background von Hippel-Lindau (VHL disease is a hereditary cancer syndrome caused by germline mutations in the VHL gene. Patients have significant morbidity and mortality secondary to vascular tumors. Disease management is centered on tumor surveillance that allows early detection and treatment. Presymptomatic genetic testing is therefore recommended, including in at-risk children. Methods We tested 17 families (n = 109 individuals for VHL mutations including 43 children under the age of 18. Personalized genetic counseling was provided pre and post-test and the individuals undergoing presymptomatic testing filled out questionnaires gathering socio-demographic, psychological and psychiatric data. Mutation analysis was performed by direct sequencing of the VHL gene. Mutation-carriers were screened for VHL disease-related tumors and were offered follow-up annual examinations. Results Mutations were identified in 36 patients, 17 of whom were asymptomatic. In the initial screening, we identified at least one tumor in five of 17 previously asymptomatic individuals. At the end of five years, only 38.9% of the mutation-carriers continued participating in our tumor surveillance program. During this time, 14 mutation carriers developed a total of 32 new tumors, three of whom died of complications. Gender, education, income, marital status and religiosity were not found to be associated with adherence to the surveillance protocol. Follow-up adherence was also independent of pre-test depression, severity of disease, or number of affected family members. The only statistically significant predictor of adherence was being symptomatic at the time of testing (OR = 5; 95% CI 1.2 - 20.3; p = 0.02. Pre-test anxiety was more commonly observed in patients that discontinued follow-up (64.7% vs. 35.3%; p = 0.01. Conclusions The high initial uptake rate of genetic testing for VHL disease, including in minors, allowed the discontinuation of unnecessary screening

  10. Standard Errors and Confidence Intervals of Norm Statistics for Educational and Psychological Tests.

    Science.gov (United States)

    Oosterhuis, Hannah E M; van der Ark, L Andries; Sijtsma, Klaas

    2016-11-14

    Norm statistics allow for the interpretation of scores on psychological and educational tests, by relating the test score of an individual test taker to the test scores of individuals belonging to the same gender, age, or education groups, et cetera. Given the uncertainty due to sampling error, one would expect researchers to report standard errors for norm statistics. In practice, standard errors are seldom reported; they are either unavailable or derived under strong distributional assumptions that may not be realistic for test scores. We derived standard errors for four norm statistics (standard deviation, percentile ranks, stanine boundaries and Z-scores) under the mild assumption that the test scores are multinomially distributed. A simulation study showed that the standard errors were unbiased and that corresponding Wald-based confidence intervals had good coverage. Finally, we discuss the possibilities for applying the standard errors in practical test use in education and psychology. The procedure is provided via the R function check.norms, which is available in the mokken package.

  11. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    International Nuclear Information System (INIS)

    Christie, B.

    1996-01-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. open-quotes Conditional Probabilitiesclose quotes of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps

  12. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christie, B.

    1996-12-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. {open_quotes}Conditional Probabilities{close_quotes} of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps.

  13. The 5th surveillance testing for Kori unit 1 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed primarily by Korea Atomic Energy Research Institute and Westinhouse corporation partially involved in testing and calculation data evaluation in order to obtain reliable test result. Fast neutron fluences for capsule V, T, S, R and P were 5.087E+18, 1.115E+19, 1.228E+19, 2.988E+19, and 3.938E+19n/cm2, respectively. The bias factor, the ratio of calculation/measurement, was 0.940 for the 1st through 5th testing and the calculational uncertainty, 7% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.9846E+19n/cm{sup 2} based on the end of 17th fuel cycle and it was predicted that the fluences of vessel inside surface at 24, 32, 40 and 48EFPY would reach 3.0593E+19, 4.0695E+19, 5.0797E+19 and 6.0900E+19n/cm{sup 2} based on the current calculation. PTS analysis for Kori unit 1 showed that 27.93EFPY was the threshold value for 300 deg F requirement. 71 refs., 33 figs., 52 tabs. (Author)

  14. Conditional dependence between tests affects the diagnosis and surveillance of animal diseases

    DEFF Research Database (Denmark)

    Gardner, I.A.; Stryhn, Henrik; Lind, Peter

    2000-01-01

    Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel te...... for toxoplasmosis and brucellosis in swine, and Johne's disease in cattle to illustrate calculation methods and to indicate the likely magnitude of the dependence between serologic tests used for diagnosis and surveillance of animal diseases.......Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel test...... interpretation and a positive dependence in test specificity reduces the specificity of serial interpretation. We calculate conditional covariances as a measure of dependence between binary tests and show their relationship to kappa (a chance-corrected measure of test agreement). We use published data...

  15. Risk factors for changing test classification in the Danish surveillance program for Salmonella in dairy herds

    DEFF Research Database (Denmark)

    Nielsen, Lennarth Ravn; Warnick, L. D.; Greiner, M.

    2007-01-01

    A surveillance program in which all cattle herds in Denmark are classified into Salmonella infection categories has been in place since 2002. Dairy herds were considered test negative and thus most likely free of infection if Salmonella antibody measurements were consistently low in bulk tank milk...... between 2 consecutive quarters of the year. The Salmonella serotypes in question were Salmonella Dublin or other serotypes that cross-react with the Salmonella Dublin antigen in the ELISA (e.g., some Salmonella Typhimurium types). Two logistic regression models that accounted for repeated measurements...

  16. [Influence of object material and inter-trial interval on novel object recognition test in mice].

    Science.gov (United States)

    Li, Sheng-jian; Huang, Zhu-yan; Ye, Yi-lu; Yu, Yue-ping; Zhang, Wei-ping; Wei, Er-qing; Zhang, Qi

    2014-05-01

    To investigate the efficacy of novel object recognition (NOR) test in assessment of learning and memory ability in ICR mice in different experimental conditions. One hundred and thirty male ICR mice were randomly divided into 10 groups: 4 groups for different inter-trial intervals (ITI: 10 min, 90 min, 4 h, 24 h), 4 groups for different object materials (wood-wood, plastic-plastic, plastic-wood, wood-plastic) and 2 groups for repeated test (measured once a day or every 3 days, totally three times in each group). The locomotor tracks in the open field were recorded. The amount of time spent exploring the novel and familiar objects, the discrimination ratio (DR) and the discrimination index (DI) were analyzed. Compared with familiar object, DR and DI of novel object were both increased at ITI of 10 min and 90 min (P<0.01). Exploring time, DR and DI were greatly influenced by different object materials. DR and DI remained stable by using identical object material. NOR test could be done repeatedly in the same batch of mice. NOR test can be used to assess the learning and memory ability in mice at shorter ITI and with identical material. It can be done repeatedly.

  17. Test-compatible confidence intervals for adaptive two-stage single-arm designs with binary endpoint.

    Science.gov (United States)

    Kunzmann, Kevin; Kieser, Meinhard

    2018-01-01

    Inference after two-stage single-arm designs with binary endpoint is challenging due to the nonunique ordering of the sampling space in multistage designs. We illustrate the problem of specifying test-compatible confidence intervals for designs with nonconstant second-stage sample size and present two approaches that guarantee confidence intervals consistent with the test decision. Firstly, we extend the well-known Clopper-Pearson approach of inverting a family of two-sided hypothesis tests from the group-sequential case to designs with fully adaptive sample size. Test compatibility is achieved by using a sample space ordering that is derived from a test-compatible estimator. The resulting confidence intervals tend to be conservative but assure the nominal coverage probability. In order to assess the possibility of further improving these confidence intervals, we pursue a direct optimization approach minimizing the mean width of the confidence intervals. While the latter approach produces more stable coverage probabilities, it is also slightly anti-conservative and yields only negligible improvements in mean width. We conclude that the Clopper-Pearson-type confidence intervals based on a test-compatible estimator are the best choice if the nominal coverage probability is not to be undershot and compatibility of test decision and confidence interval is to be preserved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. The Effect of Retention Interval Task Difficulty on Young Children's Prospective Memory: Testing the Intention Monitoring Hypothesis

    Science.gov (United States)

    Mahy, Caitlin E. V.; Moses, Louis J.

    2015-01-01

    The current study examined the impact of retention interval task difficulty on 4- and 5-year-olds' prospective memory (PM) to test the hypothesis that children periodically monitor their intentions during the retention interval and that disrupting this monitoring may result in poorer PM performance. In addition, relations among PM, working memory,…

  19. Too much of a good thing? Physician practices and patient willingness for less frequent pap test screening intervals.

    Science.gov (United States)

    Meissner, Helen I; Tiro, Jasmin A; Yabroff, K Robin; Haggstrom, David A; Coughlin, Steven S

    2010-03-01

    Recent guidelines recommend longer Pap test intervals. However, physicians and patients may not be adopting these recommendations. Identify (1) physician and practice characteristics associated with recommending a less frequent interval, and (2) characteristics associated with women's willingness to adhere to a 3-year interval. We used 2 national surveys: (1) a 2006/2007 National Survey of Primary Care Physicians for physician cervical cancer screening practices (N = 1114), and (2) the 2005 Health Information Trends Survey for women's acceptance of longer Pap intervals (N = 2206). MEASURES AND METHODS: Physician recommendation regarding Pap intervals was measured using a clinical vignette involving a 35-year-old with no new sexual partners and 3 consecutive negative Pap tests; associations with independent variables were evaluated with logistic regression. In parallel models, we evaluated women's willingness to follow a 3-year Pap test interval. A minority of physicians (32%) have adopted-but more than half of women are willing to adopt-3-year Pap test intervals. In adjusted models, physician factors associated with less frequent screening were: serving a higher proportion of Medicaid patients, white, non-Hispanic race, fewer years since medical school graduation, and US Preventive Services Task Force being very influential in physician clinical practice. Women were more willing to follow a 3-year interval if they were older, but less willing if they had personal or family experiences with cancer or followed an annual Pap test schedule. Many women are accepting of a 3-year interval for Pap tests, although most primary care physicians continue to recommend shorter intervals.

  20. Standardized likelihood ratio test for comparing several log-normal means and confidence interval for the common mean.

    Science.gov (United States)

    Krishnamoorthy, K; Oral, Evrim

    2017-12-01

    Standardized likelihood ratio test (SLRT) for testing the equality of means of several log-normal distributions is proposed. The properties of the SLRT and an available modified likelihood ratio test (MLRT) and a generalized variable (GV) test are evaluated by Monte Carlo simulation and compared. Evaluation studies indicate that the SLRT is accurate even for small samples, whereas the MLRT could be quite liberal for some parameter values, and the GV test is in general conservative and less powerful than the SLRT. Furthermore, a closed-form approximate confidence interval for the common mean of several log-normal distributions is developed using the method of variance estimate recovery, and compared with the generalized confidence interval with respect to coverage probabilities and precision. Simulation studies indicate that the proposed confidence interval is accurate and better than the generalized confidence interval in terms of coverage probabilities. The methods are illustrated using two examples.

  1. Improved Confidence Intervals of a Small Probability From Pooled Testing With Misclassification

    Directory of Open Access Journals (Sweden)

    Chunling eLiu

    2013-10-01

    Full Text Available This article concerns construction of confidence intervals of theprevalence of a rare disease using Dorfman's pooled testingprocedure when the disease status is classified with an imperfectbiomarker. Such an interval can be derived by converting aconfidence interval of the probability that a group is testedpositive. The Wald confidence intervals based on normalapproximation are shown to be inefficient in terms of coverageprobability, even for relatively large number of pools. A fewalternatives are proposed and their performance is investigated interms of coverage probability and length of intervals.

  2. A retrospective study of owner-requested testing as surveillance for equine infectious anemia in Canada (2009-2012).

    Science.gov (United States)

    Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L

    2017-12-01

    This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.

  3. HIV test offers and acceptance: New York State findings from the behavioral risk factor surveillance system and the National HIV behavioral surveillance, 2011-2012.

    Science.gov (United States)

    John Leung, Shu-Yin; Sinclair, Amber H; Battles, Haven B; Swain, Carol-Ann E; French, Patrick Tyler; Anderson, Bridget J; Sowizral, Mycroft J; Ruberto, Rachael; Brissette, Ian; Lillquist, Patricia; Smith, Lou C

    2015-01-01

    The New York State HIV testing law requires that patients aged 13-64 years be offered HIV testing in health care settings. We investigated the extent to which HIV testing was offered and accepted during the 24 months after law enactment. We added local questions to the Behavioral Risk Factor Surveillance System (BRFSS) and the National HIV Behavioral Surveillance (NHBS) surveys asking respondents aged 18-64 years whether they were offered an HIV test in health care settings, and whether they had accepted testing. Statewide prevalence estimates of test offers and acceptance were obtained from a combined 2011-2012 BRFSS sample (N = 6,223). Local estimates for 2 high-risk populations were obtained from NHBS 2011 men who have sex with men (N = 329) and 2012 injection drug users (N = 188) samples. BRFSS data showed that 73% of New Yorkers received care in any health care setting in the past 12 months, of whom 25% were offered an HIV test. Sixty percent accepted the test when offered. The levels of test offer increased from 20% to 29% over time, whereas acceptance levels decreased from 68% to 53%. NHBS data showed that 81% of men who have sex with men received care, of whom 43% were offered an HIV test. Eighty-eight percent accepted the test when offered. Eighty-five percent of injection drug users received care, of whom 63% were offered an HIV test, and 63% accepted the test when offered. We found evidence of partial and increasing implementation of the HIV testing law. Importantly, these studies demonstrated New Yorkers' willingness to accept an offered HIV test as part of routine care in health care settings.

  4. Reliability of case definitions for public health surveillance assessed by Round-Robin test methodology

    Directory of Open Access Journals (Sweden)

    Claus Hermann

    2006-05-01

    Full Text Available Abstract Background Case definitions have been recognized to be important elements of public health surveillance systems. They are to assure comparability and consistency of surveillance data and have crucial impact on the sensitivity and the positive predictive value of a surveillance system. The reliability of case definitions has rarely been investigated systematically. Methods We conducted a Round-Robin test by asking all 425 local health departments (LHD and the 16 state health departments (SHD in Germany to classify a selection of 68 case examples using case definitions. By multivariate analysis we investigated factors linked to classification agreement with a gold standard, which was defined by an expert panel. Results A total of 7870 classifications were done by 396 LHD (93% and all SHD. Reporting sensitivity was 90.0%, positive predictive value 76.6%. Polio case examples had the lowest reporting precision, salmonellosis case examples the highest (OR = 0.008; CI: 0.005–0.013. Case definitions with a check-list format of clinical criteria resulted in higher reporting precision than case definitions with a narrative description (OR = 3.08; CI: 2.47–3.83. Reporting precision was higher among SHD compared to LHD (OR = 1.52; CI: 1.14–2.02. Conclusion Our findings led to a systematic revision of the German case definitions and build the basis for general recommendations for the creation of case definitions. These include, among others, that testable yes/no criteria in a check-list format is likely to improve reliability, and that software used for data transmission should be designed in strict accordance with the case definitions. The findings of this study are largely applicable to case definitions in many other countries or international networks as they share the same structural and editorial characteristics of the case definitions evaluated in this study before their revision.

  5. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  6. Environmental surveillance and research at the Nevada Test Site: The beginning and the rationale

    International Nuclear Information System (INIS)

    Elle, D.R.; Church, B.W.; Bingham, F.E.

    1990-01-01

    Concurrently with the first nuclear-weapons tests at the Nevada Test Site (NTS) in 1951, an environmental surveillance and monitoring program was established offsite. Initial emphasis was on tracking fallout clouds and measuring external radiation exposure rates. An environmental research program was also initiated. Establishment of comprehensive programs has facilitated the ability to address issues such as the inventory and distribution of radionuclides in surface soils, reconstruction of offsite population doses, and recognition of areas requiring additional information. We have learned that a successful environmental monitoring program must be flexible and responsive to change; must address public as well as technical and regulatory concerns; and results must be continuously interpreted to ensure that all pathways are considered and the programs are proactive in their approach

  7. Probabilistic safety assessment improves surveillance requirements in technical specifications

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1997-01-01

    Probabilistic Safety Assessment is widely becoming the standard method for assessing, maintaining, assuring and improving the nuclear power plant safety. To achieve one of its many potential benefits, the optimization approach of surveillance requirements in technical specifications was developed. Surveillance requirements in technical specifications define the surveillance test intervals for the equipment to be tested and the testing strategy. This optimization approach based mainly on probabilistic safety assessment results consists of three levels: component level, system level and plant level. The application of this optimization approach on system level has shown that the risk based surveillance requirements differ from existing ones in technical specifications

  8. The 4th surveillance testing for Kori unit 3 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-10-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 4.983E+18, 1.641E+19, 3.158E+19, and 4.469E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.840 for the 1st through 4th testing and the calculational uncertainty, 12% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.362E+19n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.481E+19, 4.209E+19, 5.144E+19 and 5.974E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 41 tabs. (Author)

  9. The 5th surveillance testing for Kori unit 2 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-03-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules V, R, P, T and N are 2.837E+18, 1.105E+19, 2.110E+19, 3.705E+19 and 4.831E+19n/cm{sup 2}, respectively. The bias factor, the ratio of measurement/calculation, was 0.918 for the 1st through 5th testing and the calculational uncertainty, 11.6% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.898E+19n/cm{sup 2} based on the end of 15th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 4.203E+19, 5.232E+19, 6.262E+19 and 7.291E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 49 refs., 35 figs., 48 tabs. (Author)

  10. A labelled discrete choice experiment adds realism to the choices presented: preferences for surveillance tests for Barrett esophagus

    Directory of Open Access Journals (Sweden)

    Donkers Bas

    2009-05-01

    Full Text Available Abstract Background Discrete choice experiments (DCEs allow systematic assessment of preferences by asking respondents to choose between scenarios. We conducted a labelled discrete choice experiment with realistic choices to investigate patients' trade-offs between the expected health gains and the burden of testing in surveillance of Barrett esophagus (BE. Methods Fifteen choice scenarios were selected based on 2 attributes: 1 type of test (endoscopy and two less burdensome fictitious tests, 2 frequency of surveillance. Each test-frequency combination was associated with its own realistic decrease in risk of dying from esophageal adenocarcinoma. A conditional logit model was fitted. Results Of 297 eligible patients (155 BE and 142 with non-specific upper GI symptoms, 247 completed the questionnaire (84%. Patients preferred surveillance to no surveillance. Current surveillance schemes of once every 1–2 years were amongst the most preferred alternatives. Higher health gains were preferred over those with lower health gains, except when test frequencies exceeded once a year. For similar health gains, patients preferred video-capsule over saliva swab and least preferred endoscopy. Conclusion This first example of a labelled DCE using realistic scenarios in a healthcare context shows that such experiments are feasible. A comparison of labelled and unlabelled designs taking into account setting and research question is recommended.

  11. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyeong Geun; Kim, Min Chul; Yoon, Ji Hyun; Lee, Bong Sang; Lim, Sang Yeob; Kwon, Jun Hyun [Nuclear Materials Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant’s lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

  13. Improving national surveillance of Lyme neuroborreliosis in Denmark through electronic reporting of specific antibody index testing from 2010 to 2012

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Espenhain, L; Mølbak, K

    2015-01-01

    of laboratory results, in contrast to the statutory surveillance based on manually processed notifications. Antibody index (AI) testing is the recommend laboratory test to support the diagnosis of LNB in Denmark. In the period from 2010 to 2012, 217 clinical cases of LNB were notified to the statutory...... surveillance system, while 533 cases were reported AI positive by the MiBa system. Thirty-five unconfirmed cases (29 AI-negative and 6 not tested) were notified, but not captured by MiBa. Using MiBa, the number of reported cases was increased almost 2.5 times. Furthermore, the reporting was timelier (median...

  14. Confidence intervals permit, but don't guarantee, better inference than statistical significance testing

    Directory of Open Access Journals (Sweden)

    Melissa Coulson

    2010-07-01

    Full Text Available A statistically significant result, and a non-significant result may differ little, although significance status may tempt an interpretation of difference. Two studies are reported that compared interpretation of such results presented using null hypothesis significance testing (NHST, or confidence intervals (CIs. Authors of articles published in psychology, behavioural neuroscience, and medical journals were asked, via email, to interpret two fictitious studies that found similar results, one statistically significant, and the other non-significant. Responses from 330 authors varied greatly, but interpretation was generally poor, whether results were presented as CIs or using NHST. However, when interpreting CIs respondents who mentioned NHST were 60% likely to conclude, unjustifiably, the two results conflicted, whereas those who interpreted CIs without reference to NHST were 95% likely to conclude, justifiably, the two results were consistent. Findings were generally similar for all three disciplines. An email survey of academic psychologists confirmed that CIs elicit better interpretations if NHST is not invoked. Improved statistical inference can result from encouragement of meta-analytic thinking and use of CIs but, for full benefit, such highly desirable statistical reform requires also that researchers interpret CIs without recourse to NHST.

  15. Extended Result Reading Window in Lateral Flow Tests Detecting Exposure to Onchocerca volvulus: A New Technology to Improve Epidemiological Surveillance Tools

    Science.gov (United States)

    Golden, Allison; Steel, Cathy; Yokobe, Lindsay; Jackson, Emily; Barney, Rebecca; Kubofcik, Joseph; Peck, Roger; Unnasch, Thomas R.; Nutman, Thomas B.; de los Santos, Tala; Domingo, Gonzalo J.

    2013-01-01

    Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov). An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%–92.0%), and specificity of 97% (95% confidence interval: 95.4%–98.6%). Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives). We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity) and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96). We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test. PMID:23935960

  16. Extended result reading window in lateral flow tests detecting exposure to Onchocerca volvulus: a new technology to improve epidemiological surveillance tools.

    Directory of Open Access Journals (Sweden)

    Allison Golden

    Full Text Available Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov. An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%-92.0%, and specificity of 97% (95% confidence interval: 95.4%-98.6%. Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives. We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96. We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test.

  17. Exploring the Benefits of Molecular Testing for Gonorrhoea Antibiotic Resistance Surveillance in Remote Settings.

    Directory of Open Access Journals (Sweden)

    Ben B Hui

    Full Text Available Surveillance for gonorrhoea antimicrobial resistance (AMR is compromised by a move away from culture-based testing in favour of more convenient nucleic acid amplification test (NAAT tests. We assessed the potential benefit of a molecular resistance test in terms of the timeliness of detection of gonorrhoea AMR.An individual-based mathematical model was developed to describe the transmission of gonorrhoea in a remote Indigenous population in Australia. We estimated the impact of the molecular test on the time delay between first importation and the first confirmation that the prevalence of gonorrhoea AMR (resistance proportion has breached the WHO-recommended 5% threshold (when a change in antibiotic should occur. In the remote setting evaluated in this study, the model predicts that when culture is the only available means of testing for AMR, the breach will only be detected when the actual prevalence of AMR in the population has already reached 8 - 18%, with an associated delay of ~43 - 69 months between first importation and detection. With the addition of a molecular resistance test, the number of samples for which AMR can be determined increases facilitating earlier detection at a lower resistance proportion. For the best case scenario, where AMR can be determined for all diagnostic samples, the alert would be triggered at least 8 months earlier than using culture alone and the resistance proportion will have only slightly exceeded the 5% notification threshold.Molecular tests have the potential to provide more timely warning of the emergence of gonorrhoea AMR. This in turn will facilitate earlier treatment switching and more targeted treatment, which has the potential to reduce the population impact of gonorrhoea AMR.

  18. Quality specifications for the extra-analytical phase of laboratory testing: Reference intervals and decision limits.

    Science.gov (United States)

    Ceriotti, Ferruccio

    2017-07-01

    Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Gait in children with cerebral palsy : observer reliability of Physician Rating Scale and Edinburgh Visual Gait Analysis Interval Testing scale

    NARCIS (Netherlands)

    Maathuis, KGB; van der Schans, CP; van Iperen, A; Rietman, HS; Geertzen, JHB

    2005-01-01

    The aim of this study was to test the inter- and intra-observer reliability of the Physician Rating Scale (PRS) and the Edinburgh Visual Gait Analysis Interval Testing (GAIT) scale for use in children with cerebral palsy (CP). Both assessment scales are quantitative observational scales, evaluating

  20. Immune trypanolysis test with blood spotted on filter paper for epidemiological surveillance of sleeping sickness.

    Science.gov (United States)

    Camara, Oumou; Camara, Mamadou; Lejon, Veerle; Ilboudo, Hamidou; Sakande, Hassane; Léno, Mamadou; Büscher, Philippe; Bucheton, Bruno; Jamonneau, Vincent

    2014-07-01

    The immune trypanolysis test (TL) is an accurate sero-diagnostic tool increasingly implemented for sleeping sickness medical surveillance, but it is restricted to the reference laboratories. To facilitate storage and transport of the test specimen, we developed a protocol for the examination of blood spotted on filter paper (TL-fp) that can be stored and shipped at ambient temperature. We compared its performance with the classical TL on plasma (TL-pl) that needs to be kept frozen until use. The study was conducted in active foci of the Republic of Guinea. In total, 438 specimens from treated and untreated sleeping sickness patients and serological suspects were tested with both methods. TL-fp gave significantly less positive results than TL-pl, but all the confirmed sleeping sickness cases were positive with the TL-fp protocol. TL-fp appears to offer a good compromise between feasibility and sensitivity to detect currently infected subjects who play a role in the transmission of Trypanosoma brucei gambiense and is useful for contributing to the elimination of gambiense sleeping sickness. © 2014 John Wiley & Sons Ltd.

  1. Definition and taxonomy of interval colorectal cancers: a proposal for standardising nomenclature

    NARCIS (Netherlands)

    Sanduleanu, S.; le Clercq, C. M. C.; Dekker, E.; Meijer, G. A.; Rabeneck, L.; Rutter, M. D.; Valori, R.; Young, G. P.; Schoen, R. E.

    2015-01-01

    Interval colorectal cancers (interval CRCs), that is, cancers occurring after a negative screening test or examination, are an important indicator of the quality and effectiveness of CRC screening and surveillance. In order to compare incidence rates of interval CRCs across screening programmes, a

  2. Student Drug Testing and the Surveillance School Economy: An Analysis of Media Representation and Policy Transfer in Australian Schools

    Science.gov (United States)

    Taylor, Emmeline

    2018-01-01

    Anxieties relating to the health, safety and security of schoolchildren have been met with a variety of surveillance apparatus in schools internationally. Drawing on findings from a content analysis of newspaper reports relating to drug testing in Australian schools, this article seeks to excavate the ways in which the media shapes, informs,…

  3. Estimation of RPV material embrittlement for Ukrainian NPP based on surveillance test data

    International Nuclear Information System (INIS)

    Revka, V.; Chyrko, L.; Chaikovsky, Yu.; Gulchuk, Yu.

    2012-01-01

    The WWER-1000 RPV material embrittlement has been evaluated using the surveillance test data for the nuclear power plant which is under operation in Ukraine. The RPV materials after the neutron (E > 0,5 MeV) irradiation up to fluence of 22,9.10 22 m -2 have been studied. Fracture toughness tests were performed using pre-cracked Charpy specimens for the beltline materials (base and weld metal). The maximum shift of T 0 reference temperature is equal to 44 o C. A radiation embrittlement rate, A F , for the RPV materials was estimated using the standard and reconstituted specimens. A comparison of the A F values has shown a good agreement between the specimen sets before and after reconstitution both for base and weld metal. Furthermore it has been revealed there is no nickel effect for the studied materials. In spite of the high nickel content the radiation embrittlement rate for weld metal is not higher than for base metal with low nickel content. Fracture toughness analysis has shown the Master curve shape describes well a temperature dependence of K Jc values. However a higher scatter of K Jc values is observed in comparison to 95 % tolerance bounds. (author)

  4. Influence of rest interval on foot-tibia coordination with chronic ankle instability during the Star Excursion Balance Test.

    Science.gov (United States)

    Kwon, Yong Ung; Arnold, Brent L; Powell, Douglas W; Williams, D S Blaise

    2018-04-01

    The purpose of this study was to determine whether different rest intervals affect performance on the Star Excursion Balance Test (SEBT) associated with chronic ankle instability (CAI) and whether foot-tibia coordination can be associated factors that may help discriminate between individuals with and without CAI during the SEBT. Participants included forty-eight individuals with (n = 24) and without CAI (n = 24). Subjects completed 3 trials in each of the 3 reach directions (anteromedial, medial, posteromedial) in random order. A total of three visits were required to complete the 3 rest interval conditions (10, 20, 40 s). Coupling angles (CA) of tibial internal rotation/dorsiflexion (TIR/DF) and tibial internal rotation/eversion (TIR/EV) were calculated and compared between groups in each direction for each rest interval. Individuals with CAI showed greater CAs of TIR/DF in the M direction (p = 0.01) and of TIR/EV in the P direction (p = 0.04) than healthy individuals in 20 s rest interval time. Overall, joint CAs were different between healthy individuals and those with CAI during the SEBT regardless of rest interval. Based on these results, rest interval and a natural result of CAI could alter ankle joint coordination in comparison of healthy individuals when performing the SEBT. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Logrank Test and Interval Overlap Test for Bactericera cockerelli (Hemiptera: Triozidae) Under Different Fertilization Treatments for 7705 Tomato Hybrid

    Science.gov (United States)

    Vargas-Madríz, Haidel; Bautista-Martínez, Néstor; Vera-Graziano, Jorge; Sánchez-García, Prometeo; García-Gutiérrez, Cipriano; Sánchez-Soto, Saúl; de Jesús García-Avila, Clemente

    2014-01-01

    Abstract It is known that some nutrients can have both negative and positive effects on some populations of insects. To test this, the Logrank test and the Interval Overlap Test were evaluated for two crop cycles (February–May and May–August) of the 7705 tomato hybrid, and the effect on the psyllid, Bactericera cockerelli (Sulc.) (Hemiptera: Triozidae), was examined under greenhouse conditions. Tomato plants were in polythene bags and irrigated with the following solutions: T1—Steiner solution, T2—Steiner solution with nitrogen reduced to 25%, T3—Steiner solution with potassium reduced to 25%, and T4—Steiner solution with calcium reduced to 25%. In the Logrank test, a significant difference was found when comparing the survival parameters of B. cockerelli generated from the treatment cohorts: T1–T2; T1–T3; T1–T4; T2–T3; and T3–T4, while no significant differences were found in the T2–T4 comparison in the February–May cycle. In the May–August cycle, significant differences were found when comparing the survival parameters generated from the treatment cohorts: T1–T2; T1–T3; and T1–T4, while no significant differences were found in the T2–T3; T2–T4; and T3–T4 comparisons of survival parameters of B. cockerelli fed with the 7705 tomato hybrid. Also, the Interval Overlap Test was done on the treatment cohorts (T1, T2, T3, and T4) in the February–May and May–August cycles. T1 and T2 compare similarly in both cycles when feeding on the treatments up to 36 d. Similarly, in T1 and T3, the behavior of the insect is similar when feeding on the treatments up to 40 and 73 d, respectively. Comparisons T2–T3 and T2–T4 are similar when feeding on both treatments up to 42, 38 and 37, 63 d, respectively. Finally, the T3–T4 comparison was similar when feeding in both treatments up to 20 and 46 d, respectively. RESUMEN. Se sabe que algunos nutrientes pueden tener efectos tanto negativos como positivos en algunas poblaciones de

  6. Experience gained with the development of a performance test program for the monitoring and surveillance systems in the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Arestin, M.L.

    1988-01-01

    The monitoring and surveillance system for Embalse nuclear power plant are presented. The reactor, the nuclear fuel management, the equipments from monitoring and surveillance system, the activities developed by the AIEA experts in each mission of this test program and the management of the components for this test program in Argentine are described. (E.G.) [pt

  7. 300-Area VOC Program Slug Test Characterization Results for Selected Test/Depth Intervals Conducted During the Drilling of Well 399-3-21

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.

    2007-07-19

    This report presents brief test descriptions and analysis results for multiple, stress-level slug tests that were performed at selected test/depth intervals within well 399-3-21 as part of the 300-Area volatile organic compound characterization program. The test intervals were characterized as the borehole was advanced to its final drill depth (45.7 m) and before its completion as a monitor-well facility. The primary objective of the slug tests was to provide information pertaining to the vertical distribution of hydraulic conductivity with depth at this location and to select the final screen-depth interval for the monitor well. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor-well strategies within this area.

  8. Reference intervals for plasma free metanephrines with an age adjustment for normetanephrine for optimized laboratory testing of phaeochromocytoma

    NARCIS (Netherlands)

    Eisenhofer, G.; Lattke, P.; Herberg, M.; Siegert, G.; Qin, N.; Darr, R.; Hoyer, J.; Villringer, A.; Prejbisz, A.; Januszewicz, A.; Remaley, A.; Martucci, V.; Pacak, K.; Ross, H.A.; Sweep, F.C.; Lenders, J.W.M.

    2013-01-01

    BACKGROUND: Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This

  9. Population Validity and Cross-Validity: Applications of Distribution Theory for Testing Hypotheses, Setting Confidence Intervals, and Determining Sample Size

    Science.gov (United States)

    Algina, James; Keselman, H. J.

    2008-01-01

    Applications of distribution theory for the squared multiple correlation coefficient and the squared cross-validation coefficient are reviewed, and computer programs for these applications are made available. The applications include confidence intervals, hypothesis testing, and sample size selection. (Contains 2 tables.)

  10. Specific antigen serologic tests in leprosy: implications for epidemiological surveillance of leprosy cases and household contacts

    Directory of Open Access Journals (Sweden)

    Ana Paula Mendes Carvalho

    Full Text Available BACKGROUND There is a lack of straightforward tests for field application and known biomarkers for predicting leprosy progression in infected individuals. OBJECTIVE The aim was to analyse the response to infection by Mycobacterium leprae based on the reactivity of specific antigens: natural disaccharide linked to human serum albumin via an octyl (NDOHSA, a semisynthetic phenolic glycolipid-I (PGL-I; Leprosy Infectious Disease Research Institute Diagnostic-1 (LID-1 and natural disaccharide octyl - Leprosy Infectious Disease Research Institute Diagnostic-1 (NDOLID. METHODS The study population consisted of 130 leprosy cases diagnosed between 2010 and 2015 and 277 household contacts. An enzyme-linked immunosorbent assay (ELISA was used to analyse the reactivity of antibodies against NDOHSA, LID-1 and NDOLID. The samples and controls were tested in duplicate, and the antibody titer was expressed as an ELISA index. Data collection was made by home visits with application of questionnaire and dermatological evaluation of all household contacts to identify signs and symptoms of leprosy. FINDINGS Significant differences in the median ELISA results were observed among leprosy cases in treatment, leprosy cases that had completed treatment and household contacts. Higher proportions of seropositivity were observed in leprosy cases in treatment. Seropositivity was also higher in multibacillary in relation to paucibacillary, with the difference reaching statistical significance. Lower titers were observed among cases with a longer treatment time or discharge. For household contacts, the differences according to the clinical characteristics of the leprosy index case were less pronounced than expected. Other factors, such as the endemicity of leprosy, exposure outside the residence and genetic characteristics, appeared to have a greater influence on the seropositivity. MAIN CONCLUSIONS Serologic tests could be used as auxiliary tools for determining the

  11. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Science.gov (United States)

    Murphy, Sean C; Hermsen, Cornelus C; Douglas, Alexander D; Edwards, Nick J; Petersen, Ines; Fahle, Gary A; Adams, Matthew; Berry, Andrea A; Billman, Zachary P; Gilbert, Sarah C; Laurens, Matthew B; Leroy, Odile; Lyke, Kristen E; Plowe, Christopher V; Seilie, Annette M; Strauss, Kathleen A; Teelen, Karina; Hill, Adrian V S; Sauerwein, Robert W

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA) program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally <0.5 log10 parasites/mL except for one laboratory where the EQA effort identified likely reasons for a general quantitative shift. The within-laboratory variation for all assays was low at <10% coefficient of variation across a range of parasite densities. Based on this study, we propose to create a Molecular Malaria Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  12. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Directory of Open Access Journals (Sweden)

    Sean C Murphy

    Full Text Available Nucleic acid testing (NAT for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally <0.5 log10 parasites/mL except for one laboratory where the EQA effort identified likely reasons for a general quantitative shift. The within-laboratory variation for all assays was low at <10% coefficient of variation across a range of parasite densities. Based on this study, we propose to create a Molecular Malaria Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  13. Standard errors and confidence intervals of norm statistics for educational and psychological tests

    NARCIS (Netherlands)

    Oosterhuis, H.E.M.; van der Ark, L.A.; Sijtsma, K.

    2017-01-01

    Norm statistics allow for the interpretation of scores on psychological and educational tests, by relating the test score of an individual test taker to the test scores of individuals belonging to the same gender, age, or education groups, et cetera. Given the uncertainty due to sampling error, one

  14. Standard errors and confidence intervals of norm statistics for educational and psychological tests

    NARCIS (Netherlands)

    Oosterhuis, H.E.M.; van der Ark, L.A.; Sijtsma, K.

    Norm statistics allow for the interpretation of scores on psychological and educational tests, by relating the test score of an individual test taker to the test scores of individuals belonging to the same gender, age, or education groups, et cetera. Given the uncertainty due to sampling error, one

  15. Use of Reactor Pressure Vessel Surveillance Materials for Extended Life Evaluations Using Power and Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Server, W.L.; Nanstad, R.K.; Odette, G.R.

    2012-01-01

    The most important component in assuring safety of the nuclear power plant is the reactor pressure (RPV). Surveillance programs have been designed to cover the licensed life of operating nuclear RPVs. The original surveillance programs were designed when the licensed life was 40 years. More than one-half of the operating nuclear plants in the USA have an extended license out to 60 years, and there are plans to continue to operate many plants out to 80 years. Therefore, the surveillance programs have had to be adjusted or enhanced to generate key data for 60 years, and now consideration must be given for 80 or more years. To generate the necessary data to assure safe operation out to these extended license lives, test reactor irradiations have been initiated with key RPV and model alloy steels, which include several steels irradiated in the current power reactor surveillance programs out to relatively high fluence levels. These data are crucial in understanding the radiation embrittlement mechanisms and to enable extrapolation of the irradiation effects on mechanical properties for these extended time periods. This paper describes the potential radiation embrittlement mechanisms and effects when assessing much longer operating times and higher neutron fluence levels. Potential methods for adjusting higher neutron flux test reactor data for use in predicting power reactor vessel conditions are discussed. (author)

  16. Performance of 225 Dutch school children on Rey's Auditory Verbal Learning Test (AVLT) : Parallel test-retest reliabilities with an interval of 3 months and normative data

    NARCIS (Netherlands)

    Van den Burg, W.

    Performance on Dutch adaptations of Rey's AVLT was examined in a sample of 225 6- to 12-year-old Dutch school children, selected to be representative of the general population. With an interval of 3 months, they were tested twice, using two out of three test forms which proved to be parallel. No

  17. Increased accuracy of a novel mRNA-based urine test for bladder cancer surveillance.

    Science.gov (United States)

    Pichler, Renate; Fritz, Josef; Tulchiner, Gennadi; Klinglmair, Gerald; Soleiman, Afschin; Horninger, Wolfgang; Klocker, Helmut; Heidegger, Isabel

    2018-01-01

    To evaluate the diagnostic accuracy of the Xpert Bladder Cancer (BC) Monitor, compared with cystoscopy and cytology in the oncological follow-up of non-muscle-invasive bladder cancer (NMIBC). A total of 140 patients with a history of NMIBC undergoing routine surveillance at our institution were enrolled prospectively in this study (ISRCTN study registry number 37210907). Urine cytology was evaluated according to the Paris classification system. In addition, urinary specimens were analysed using the Xpert BC Monitor, which measures five target mRNAs (ABL1, CRH, IGF2, UPK1B, ANXA10) using real-time PCR. Descriptive analysis, diagnostic accuracy including sensitivity, specificity, positive (PPV) and negative predictive value (NPV), receiver-operating characteristic curve, and area under the curve (AUC) were calculated. The overall sensitivity (0.84) and NPV (0.93) of the Xpert BC Monitor were significantly superior to those of bladder washing cytology (0.33 and 0.76; P < 0.001). Subgroup analyses confirmed the high sensitivity of the Xpert BC Monitor even in low-grade (0.77) and pTa (0.82) disease compared with barbotage cytology (low-grade: 0.13; pTa: 0.21). The overall specificity of the Xpert BC Monitor and barbotage cytology was similar (0.91 vs 0.94; P = 0.41). Combining the Xpert BC Monitor with barbotage cytology (AUC = 0.85) did not enhance diagnostic performance compared with the performance of the Xpert BC Monitor alone (AUC = 0.87). In this study, we report for the first time that the Xpert BC Monitor, a new mRNA-based urine test, outperforms cytology with regard to sensitivity and NPV, even in low-grade and pTa tumours, with no reduction of specificity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  18. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  19. Appropriateness of endoscopic surveillance recommendations in organised colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Turrin, Anna; Mantellini, Paola; Visioli, Carmen Beatriz; Naldoni, Carlo; Sassoli De' Bianchi, Priscilla; Fedato, Chiara; Anghinoni, Emanuela; Zappa, Marco; Hassan, Cesare

    2016-11-01

    To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). 74 Italian CRC screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013. 49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05). In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. A Comparative Test of the Interval-Scale Properties of Magnitude Estimation and Case III Scaling and Recommendations for Equal-Interval Frequency Response Anchors.

    Science.gov (United States)

    Schriesheim, Chester A.; Novelli, Luke, Jr.

    1989-01-01

    Differences between recommended sets of equal-interval response anchors derived from scaling techniques using magnitude estimations and Thurstone Case III pair-comparison treatment of complete ranks were compared. Differences in results for 205 undergraduates reflected differences in the samples as well as in the tasks and computational…

  1. Molecular stool testing as an alternative for surveillance colonoscopy: a cross-sectional cohort study

    NARCIS (Netherlands)

    van Lanschot, Meta C. J.; Carvalho, Beatriz; Coupé, Veerle M. H.; van Engeland, Manon; Dekker, Evelien; Meijer, Gerrit A.

    2017-01-01

    Background: As in many other European countries, a nationwide screening program for colorectal cancer (CRC) has recently been introduced in the Netherlands. As a side effect, such a screening program will inherently yield an increase in the demand for surveillance after removal of polyps/adenomas or

  2. An Analysis of the Speed Commands from an Interval Management Algorithm during the ATD-1 Flight Test

    Science.gov (United States)

    Watters, Christine; Wilson, Sara R.; Swieringa, Kurt A.

    2017-01-01

    NASA's first Air Traffic Management Technology Demonstration (ATD-1) successfully completed a nineteen-day flight test under a NASA contract with Boeing, with Honeywell and United Airlines as sub-contractors. An Interval Management (IM) avionics prototype was built based on international IM standards, integrated into two test aircraft, and then flown in real-world conditions to determine if the goals of improving aircraft efficiency and airport throughput during high-density arrival operations could be met. This paper describes the speed behavior of the IM avionics prototype, focusing on the speed command rate and the number of speed increases.

  3. How to Learn Effectively in Medical School: Test Yourself, Learn Actively, and Repeat in Intervals

    OpenAIRE

    Augustin, Marc

    2014-01-01

    Students in medical school often feel overwhelmed by the excessive amount of factual knowledge they are obliged to learn. Although a large body of research on effective learning methods is published, scientifically based learning strategies are not a standard part of the curriculum in medical school. Students are largely unaware of how to learn successfully and improve memory. This review outlines three fundamental methods that benefit learning: the testing effect, active recall, and spaced r...

  4. Tracer Test Monitoring Using Wells with Long Screened Intervals : Benefits and Disadvantages

    OpenAIRE

    Schnegg, Pierre-André; Flynn, Raymond Matthew; Mallèn, German; Perrochet, Pierre

    2005-01-01

    Analytical and economic limitations often make fully-penetrating wells an attractive alternative for monitoring tracer test responses in aquifers. Modelling of breakthrough curves generated using long-screened (LS) wells in an unconfined gravel aquifer demonstrated that prolonged tailing could be reproduced with a series of partial breakthrough curves. The results suggested tracer arrived at multiple horizons. Subsequent measurements using a mobile downhole fluorometer demonstrated over 95% o...

  5. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  6. How to learn effectively in medical school: test yourself, learn actively, and repeat in intervals.

    Science.gov (United States)

    Augustin, Marc

    2014-06-01

    Students in medical school often feel overwhelmed by the excessive amount of factual knowledge they are obliged to learn. Although a large body of research on effective learning methods is published, scientifically based learning strategies are not a standard part of the curriculum in medical school. Students are largely unaware of how to learn successfully and improve memory. This review outlines three fundamental methods that benefit learning: the testing effect, active recall, and spaced repetition. The review summarizes practical learning strategies to learn effectively and optimize long-term retention of factual knowledge.

  7. Ground Testing of Prototype Hardware and Processing Algorithms for a Wide Area Space Surveillance System (WASSS)

    Science.gov (United States)

    Goldstein, N.; Dressler, R. A.; Richtsmeier, S. S.; McLean, J.; Dao, P. D.; Murray-Krezan, J.; Fulcoly, D. O.

    2013-09-01

    Recent ground testing of a wide area camera system and automated star removal algorithms has demonstrated the potential to detect, quantify, and track deep space objects using small aperture cameras and on-board processors. The camera system, which was originally developed for a space-based Wide Area Space Surveillance System (WASSS), operates in a fixed-stare mode, continuously monitoring a wide swath of space and differentiating celestial objects from satellites based on differential motion across the field of view. It would have greatest utility in a LEO orbit to provide automated and continuous monitoring of deep space with high refresh rates, and with particular emphasis on the GEO belt and GEO transfer space. Continuous monitoring allows a concept of change detection and custody maintenance not possible with existing sensors. The detection approach is equally applicable to Earth-based sensor systems. A distributed system of such sensors, either Earth-based, or space-based, could provide automated, persistent night-time monitoring of all of deep space. The continuous monitoring provides a daily record of the light curves of all GEO objects above a certain brightness within the field of view. The daily updates of satellite light curves offers a means to identify specific satellites, to note changes in orientation and operational mode, and to queue other SSA assets for higher resolution queries. The data processing approach may also be applied to larger-aperture, higher resolution camera systems to extend the sensitivity towards dimmer objects. In order to demonstrate the utility of the WASSS system and data processing, a ground based field test was conducted in October 2012. We report here the results of the observations made at Magdalena Ridge Observatory using the prototype WASSS camera, which has a 4×60° field-of-view , <0.05° resolution, a 2.8 cm2 aperture, and the ability to view within 4° of the sun. A single camera pointed at the GEO belt provided a

  8. Pacemaker patients’ perspective and experiences in a pacemaker outpatient clinic in relation to test intervals of the pacemaker

    DEFF Research Database (Denmark)

    Lauberg, Astrid; Hansen, Tina; Pedersen, Trine Pernille Dahl

    an evident decline in quality of life regarding psychological and social aspects 6 month after the implantation in terms of cognitive function, work ability, and sexual activity. Mlynarski et al (2009) have found correlations between pacemaker implantation and anxiety and depression. Aim The aim...... the pacemaker and psychological reactions. Patients with pacemakers older than 3 months lacked communication with fellowmen. Conclusion The patients express receiving competent and professional treatment when visiting the outpatient clinic, there seems to be a discrepancy between the long test intervals...... and the critical period in which anxiety and depression may occur. Minor problems and questions may grow into fatal conditions if the patients are not offered an opportunity to discuss this with experts. Patients are not informed that it is possible to discuss problems that imply psychological topics and they do...

  9. Optimization of the test intervals of a nuclear safety system by genetic algorithms, solution clustering and fuzzy preference assignment

    Energy Technology Data Exchange (ETDEWEB)

    Zio, E. [Ecole Centrale Paris- Supelec, Paris (France); Bazzo, R. [Politecnico di Milano, Milano (Italy)

    2010-08-15

    In this paper, a procedure is developed for identifying a number of representative solutions manageable for decision-making in a multiobjective optimization problem concerning the test intervals of the components of a safety system of a nuclear power plant. Pareto Front solutions are identified by a genetic algorithm and then clustered by subtractive clustering into 'families'. On the basis of the decision maker's preferences, each family is then synthetically represented by a 'head of the family' solution. This is done by introducing a scoring system that ranks the solutions with respect to the different objectives: a fuzzy preference assignment is employed to this purpose. Level Diagrams are then used to represent, analyze and interpret the Pareto Fronts reduced to the head-of-the-family solutions

  10. Optimization of the test intervals of a nuclear safety system by genetic algorithms, solution clustering and fuzzy preference assignment

    International Nuclear Information System (INIS)

    Zio, E.; Bazzo, R.

    2010-01-01

    In this paper, a procedure is developed for identifying a number of representative solutions manageable for decision-making in a multiobjective optimization problem concerning the test intervals of the components of a safety system of a nuclear power plant. Pareto Front solutions are identified by a genetic algorithm and then clustered by subtractive clustering into 'families'. On the basis of the decision maker's preferences, each family is then synthetically represented by a 'head of the family' solution. This is done by introducing a scoring system that ranks the solutions with respect to the different objectives: a fuzzy preference assignment is employed to this purpose. Level Diagrams are then used to represent, analyze and interpret the Pareto Fronts reduced to the head-of-the-family solutions

  11. Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Directory of Open Access Journals (Sweden)

    Sluiter Judith K

    2010-02-01

    Full Text Available Abstract Background Clinimetric data for the fire fighting simulation test (FFST, a new test proposed for the Workers' Health Surveillance (WHS of Dutch fire fighters, were evaluated. Methods Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC, and standard error of measurement (SEM, were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. Results The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p Conclusions The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.

  12. First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

    Science.gov (United States)

    Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie

    2013-01-01

    Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all

  13. First definition of reference intervals of liver function tests in China: a large-population-based multi-center study about healthy adults.

    Directory of Open Access Journals (Sweden)

    Runqing Mu

    Full Text Available BACKGROUND: Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. METHODS: A total of 3210 individuals (20-79 years were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA of China. RESULTS: We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin, age(ALP, albumin and region(total protein. More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%, ALP (0.2%, albumin (0.0%. Most of reference intervals in our study were obviously different from that of other races. CONCLUSION: These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA

  14. Interval Training

    Science.gov (United States)

    Healthy Lifestyle Fitness Interval training can help you get the most out of your workout. By Mayo Clinic Staff Are you ready to shake up ... more time at the gym? Consider aerobic interval training. Once the domain of elite athletes, interval training ...

  15. An evaluation of the B ampersand W Owners Group BAW-10182 topical report: Justification for increasing the engineered safety features actuation system on-line test intervals

    International Nuclear Information System (INIS)

    Smith, C.L.; Hansen, J.L.

    1993-09-01

    This Technical Evaluation Report provides an evaluation of the Babcock and Wilcox Owners Group (B ampersand WOG) Technical Specifications Committee Topical Report BAW-10182, entitled, ''Justification for Increasing Engineered Safety Features Actuation System (ESFAS) On-Line Test Intervals.'' This evaluation was performed by the Idaho National Engineering Laboratory in support of the Nuclear Regulatory Commission. The BAW-10182 report presents justification for the extension of on-line test intervals from the existing one-month interval to a three-month interval for the ESFAS system. In the BAW-10182 report, the B ampersand WOG stated that ''hor-ellipsis the B ampersand WOG proposes to increase the ESFAS test interval from one to three months and concludes that the effect on plant risk is insignificant.'' The proposed extension was based upon risk-based [i.e., probabilistic risk assessment (PRA)] methods such as reliability block diagrams, uncertainty analyses, and time-dependent system availability analyses. This use of PRA methods requires a detailed evaluation to determine whether the chosen methods and their application are valid in the context of the proposed test interval extension. The results of the evaluation agreed that the effect on plant risk is small if the ESFAS test interval is extended to three months for the ESFAS designs that were evaluated

  16. Cost-effectiveness of lobectomy versus genetic testing (Afirma®) for indeterminate thyroid nodules: Considering the costs of surveillance.

    Science.gov (United States)

    Balentine, Courtney J; Vanness, David J; Schneider, David F

    2018-01-01

    We evaluated whether diagnostic thyroidectomy for indeterminate thyroid nodules would be more cost-effective than genetic testing after including the costs of long-term surveillance. We used a Markov decision model to estimate the cost-effectiveness of thyroid lobectomy versus genetic testing (Afirma®) for evaluation of indeterminate (Bethesda 3-4) thyroid nodules. The base case was a 40-year-old woman with a 1-cm indeterminate nodule. Probabilities and estimates of utilities were obtained from the literature. Cost estimates were based on Medicare reimbursements with a 3% discount rate for costs and quality-adjusted life-years. During a 5-year period after the diagnosis of indeterminate thyroid nodules, lobectomy was less costly and more effective than Afirma® (lobectomy: $6,100; 4.50 quality-adjusted life- years vs Afirma®: $9,400; 4.47 quality-adjusted life-years). Only in 253 of 10,000 simulations (2.5%) did Afirma® show a net benefit at a cost-effectiveness threshold of $100,000 per quality- adjusted life-years. There was only a 0.3% probability of Afirma® being cost saving and a 14.9% probability of improving quality-adjusted life-years. Our base case estimate suggests that diagnostic lobectomy dominates genetic testing as a strategy for ruling out malignancy of indeterminate thyroid nodules. These results, however, were highly sensitive to estimates of utilities after lobectomy and living under surveillance after Afirma®. Published by Elsevier Inc.

  17. Comparison of approaches to estimate confidence intervals of post-test probabilities of diagnostic test results in a nested case-control study

    Directory of Open Access Journals (Sweden)

    van Zaane Bas

    2012-10-01

    Full Text Available Abstract Background Nested case–control studies become increasingly popular as they can be very efficient for quantifying the diagnostic accuracy of costly or invasive tests or (biomarkers. However, they do not allow for direct estimation of the test’s predictive values or post-test probabilities, let alone for their confidence intervals (CIs. Correct estimates of the predictive values itself can easily be obtained using a simple correction by the (inverse sampling fractions of the cases and controls. But using this correction to estimate the corresponding standard error (SE, falsely increases the number of patients that are actually studied, yielding too small CIs. We compared different approaches for estimating the SE and thus CI of predictive values or post-test probabilities of diagnostic test results in a nested case–control study. Methods We created datasets based on a large, previously published diagnostic study on 2 different tests (D-dimer test and calf difference test with a nested case–control design. We compared six different approaches; the approaches were: 1. the standard formula for the SE of a proportion, 2. adaptation of the standard formula with the sampling fraction, 3. A bootstrap procedure, 4. A approach, which uses the sensitivity, the specificity and the prevalence, 5. Weighted logistic regression, and 6. Approach 4 on the log odds scale. The approaches were compared with respect to coverage of the CI and CI-width. Results The bootstrap procedure (approach 3 showed good coverage and relatively small CI widths. Approaches 4 and 6 showed some undercoverage, particularly for the D-dimer test with frequent positive results (positive results around 70%. Approaches 1, 2 and 5 showed clear overcoverage at low prevalences of 0.05 and 0.1 in the cohorts for all case–control ratios. Conclusion The results from our study suggest that a bootstrap procedure is necessary to assess the confidence interval for the predictive

  18. Parallel island genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Pereira, Claudio M.N.A.; Lapa, Celso M.F.

    2003-01-01

    In this work, we focus the application of an Island Genetic Algorithm (IGA), a coarse-grained parallel genetic algorithm (PGA) model, to a Nuclear Power Plant (NPP) Auxiliary Feedwater System (AFWS) surveillance tests policy optimization. Here, the main objective is to outline, by means of comparisons, the advantages of the IGA over the simple (non-parallel) genetic algorithm (GA), which has been successfully applied in the solution of such kind of problem. The goal of the optimization is to maximize the system's average availability for a given period of time, considering realistic features such as: i) aging effects on standby components during the tests; ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; iii) components have distinct test parameters (outage time, aging factors, etc.) and iv) tests are not necessarily periodic. In our experiments, which were made in a cluster comprised by 8 1-GHz personal computers, we could clearly observe gains not only in the computational time, which reduced linearly with the number of computers, but in the optimization outcome

  19. Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized. 1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm2 and accurate results at higher track densities have been demonstrated for some cases. (2) Trac...

  20. Evaluation of the Trail Making Test and interval timing as measures of cognition in healthy adults: comparisons by age, education, and gender.

    Science.gov (United States)

    Płotek, Włodzimierz; Łyskawa, Wojciech; Kluzik, Anna; Grześkowiak, Małgorzata; Podlewski, Roland; Żaba, Zbigniew; Drobnik, Leon

    2014-02-03

    Human cognitive functioning can be assessed using different methods of testing. Age, level of education, and gender may influence the results of cognitive tests. The well-known Trail Making Test (TMT), which is often used to measure the frontal lobe function, and the experimental test of Interval Timing (IT) were compared. The methods used in IT included reproduction of auditory and visual stimuli, with the subsequent production of the time intervals of 1-, 2-, 5-, and 7-seconds durations with no pattern. Subjects included 64 healthy adult volunteers aged 18-63 (33 women, 31 men). Comparisons were made based on age, education, and gender. TMT was performed quickly and was influenced by age, education, and gender. All reproduced visual and produced intervals were shortened and the reproduction of auditory stimuli was more complex. Age, education, and gender have more pronounced impact on the cognitive test than on the interval timing test. The reproduction of the short auditory stimuli was more accurate in comparison to other modalities used in the IT test. The interval timing, when compared to the TMT, offers an interesting possibility of testing. Further studies are necessary to confirm the initial observation.

  1. Hui and Walter's latent-class model extended to estimate diagnostic test properties from surveillance data: a latent model for latent data.

    Science.gov (United States)

    Bermingham, Mairead L; Handel, Ian G; Glass, Elizabeth J; Woolliams, John A; de Clare Bronsvoort, B Mark; McBride, Stewart H; Skuce, Robin A; Allen, Adrian R; McDowell, Stanley W J; Bishop, Stephen C

    2015-07-07

    Diagnostic test sensitivity and specificity are probabilistic estimates with far reaching implications for disease control, management and genetic studies. In the absence of 'gold standard' tests, traditional Bayesian latent class models may be used to assess diagnostic test accuracies through the comparison of two or more tests performed on the same groups of individuals. The aim of this study was to extend such models to estimate diagnostic test parameters and true cohort-specific prevalence, using disease surveillance data. The traditional Hui-Walter latent class methodology was extended to allow for features seen in such data, including (i) unrecorded data (i.e. data for a second test available only on a subset of the sampled population) and (ii) cohort-specific sensitivities and specificities. The model was applied with and without the modelling of conditional dependence between tests. The utility of the extended model was demonstrated through application to bovine tuberculosis surveillance data from Northern and the Republic of Ireland. Simulation coupled with re-sampling techniques, demonstrated that the extended model has good predictive power to estimate the diagnostic parameters and true herd-level prevalence from surveillance data. Our methodology can aid in the interpretation of disease surveillance data, and the results can potentially refine disease control strategies.

  2. Foucault, surveillance, and carbon monoxide testing within stop-smoking services.

    Science.gov (United States)

    Grant, Aimee; Ashton, Kathryn; Phillips, Rhiannon

    2015-07-01

    Health professionals have adopted proactive testing for early evidence of disease. Researchers have identified that this leads to enumerated understandings and shapes behavior in productive ways. Smoking-cessation advisors regularly test clients for carbon monoxide (CO), but client views of this had not previously been explored. We interviewed 23 clients of a United Kingdom-based stop-smoking service regarding their experiences of CO testing. The majority of participants were successful quitters. We used ATLAS.ti 7 as a data-management tool during structured qualitative analysis. Our findings reveal that clients believed the results of their CO tests. Many became enumerated in their understanding, and thus placed themselves in a hierarchy with other members of their group. Almost all clients found that knowing their CO test score was motivating. We conclude that additional research is needed to understand the experiences of CO testing among clients who do not quit. © The Author(s) 2014.

  3. Long-Term Maintenance of Immediate or Delayed Extinction Is Determined by the Extinction-Test Interval

    Science.gov (United States)

    Johnson, Justin S.; Escobar, Martha; Kimble, Whitney L.

    2010-01-01

    Short acquisition-extinction intervals (immediate extinction) can lead to either more or less spontaneous recovery than long acquisition-extinction intervals (delayed extinction). Using rat subjects, we observed less spontaneous recovery following immediate than delayed extinction (Experiment 1). However, this was the case only if a relatively…

  4. Interval Training.

    Science.gov (United States)

    President's Council on Physical Fitness and Sports, Washington, DC.

    Regardless of the type of physical activity used, interval training is simply repeated periods of physical stress interspersed with recovery periods during which activity of a reduced intensity is performed. During the recovery periods, the individual usually keeps moving and does not completely recover before the next exercise interval (e.g.,…

  5. Tetanus Surveillance

    Science.gov (United States)

    ... Links Tetanus Vaccination Maternal and Neonatal Tetanus Elimination Surveillance Recommend on Facebook Tweet Share Compartir Reported tetanus ... date on their 10-year booster shots. National surveillance for tetanus is monitored by the National Notifiable ...

  6. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  7. Sequential probability ratio tests for reactor signal validation and sensor surveillance applications

    International Nuclear Information System (INIS)

    Humenik, K.; Gross, K.C.

    1989-01-01

    This paper examines the properties of sequential probability ratio tests (SPRT's) and the application of these tests to nuclear power reactor operation. Recently SPRT's have been applied to delayed-neutron (DN) signal data analysis using actual reactor data from the Experimental Breeder Reactor-II, which is operated by Argonne National Laboratory. The implementation of this research as part of an expert system is described. Mathematical properties of the SPRT are investigated, and theoretical results are validated with tests that use DN-signal data taken from the EBR-II in Idaho. Variations of the basic SPRT and applications to general signal validation are also explored. 16 refs., 3 figs

  8. JOINT INTELLIGENCE, SURVEILLANCE, & RECONNAISSANCE (ISR) TEST & EVALUATION (JISR-TE) FACILITY

    Data.gov (United States)

    Federal Laboratory Consortium — To meet the needs of the Warfighter, the JISR-TE facility provides the US, NATO, and Coalition members standards conformance testing of imagery capabilities across...

  9. Automatic Dependent Surveillance Broadcast: [micro]ADS-B Detect-and-Avoid Flight Tests

    Science.gov (United States)

    Arteaga, Ricardo; Dandachy, Mike

    2018-01-01

    The testing and demonstrations are necessary for both parties to further development and certification of the technology in three key areas; flights beyond line of sight, collision avoidance, and autonomous operations.

  10. Unexplained Graft Dysfunction after Heart Transplantation—Role of Novel Molecular Expression Test Score and QTc-Interval: A Case Report

    Directory of Open Access Journals (Sweden)

    Khurram Shahzad

    2010-01-01

    Full Text Available In the current era of immunosuppressive medications there is increased observed incidence of graft dysfunction in the absence of known histological criteria of rejection after heart transplantation. A noninvasive molecular expression diagnostic test was developed and validated to rule out histological acute cellular rejection. In this paper we present for the first time, longitudinal pattern of changes in this novel diagnostic test score along with QTc-interval in a patient who was admitted with unexplained graft dysfunction. Patient presented with graft failure with negative findings on all known criteria of rejection including acute cellular rejection, antibody mediated rejection and cardiac allograft vasculopathy. The molecular expression test score showed gradual increase and QTc-interval showed gradual prolongation with the gradual decline in graft function. This paper exemplifies that in patients presenting with unexplained graft dysfunction, GEP test score and QTc-interval correlate with the changes in the graft function.

  11. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  12. HIV incidence estimate combining HIV/AIDS surveillance, testing history information and HIV test to identify recent infections in Lazio, Italy

    Directory of Open Access Journals (Sweden)

    Mammone Alessia

    2012-03-01

    Full Text Available Abstract Background The application of serological methods in HIV/AIDS routine surveillance systems to identify persons with recently acquired HIV infection has been proposed as a tool which may provide an accurate description of the current transmission patterns of HIV. Using the information about recent infection it is possible to estimate HIV incidence, according to the model proposed by Karon et al. in 2008, that accounts for the effect of testing practices on the number of persons detected as recently infected. Methods We used data from HIV/AIDS surveillance in the period 2004-2008 to identify newly diagnosed persons. These were classified with recent/non-recent infection on the basis of an avidity index result, or laboratory evidence of recently acquired infection (i.e., previous documented negative HIV test within 6 months; or presence of HIV RNA or p24 antigen with simultaneous negative/indeterminate HIV antibody test. Multiple imputation was used to impute missing information. The incidence estimate was obtained as the number of persons detected as recently infected divided by the estimated probability of detection. Estimates were stratified by calendar year, transmission category, gender and nationality. Results During the period considered 3,633 new HIV diagnoses were reported to the regional surveillance system. Applying the model, we estimated that in 2004-2008 there were 5,465 new infections (95%CI: 4,538-6,461; stratifying by transmission category, the estimated number of infections was 2,599 among heterosexual contacts, 2,208 among men-who-have-sex-with-men, and 763 among injecting-drug-users. In 2008 there were 952 (625-1,229 new HIV infections (incidence of 19.9 per 100,000 person-years. In 2008, for men-who-have-sex-with-men (691 per 100,000 person-years and injecting drug users (577 per 100,000 person-years the incidence remained comparatively high with respect to the general population, although a decreasing pattern during

  13. Screening for Colorectal Cancer With Fecal Immunochemical Testing With and Without Postpolypectomy Surveillance Colonoscopy A Cost-Effectiveness Analysis

    NARCIS (Netherlands)

    Greuter, Marjolein J. E.; de Klerk, Clasine M.; Meijer, Gerrit A.; Dekker, Evelien; Coupé, Veerle M. H.

    2017-01-01

    Background: Population-based screening to prevent colorectal cancer (CRC) death is effective, but the effectiveness of post-polypectomy surveillance is unclear. Objective: To evaluate the additional benefit in terms of costeffectiveness of colonoscopy surveillance in a screening setting. Design:

  14. A pilot study to evaluate an efficient testing strategy for surveillance ...

    African Journals Online (AJOL)

    Introduction: Control strategies for schistosomiasis depend on the understanding of the population specific magnitude of the infection. We present pilot results of a testing strategy suggested by theoretical statistical investigation that lowers cost yet retains similar accuracy profile as the standard Kato-Katz technique.

  15. Neuraminidase Inhibitor Susceptibility Testing in Human Influenza Viruses: A Laboratory Surveillance Perspective

    Science.gov (United States)

    Okomo-Adhiambo, Margaret; Sleeman, Katrina; Ballenger, Kristina; Nguyen, Ha T.; Mishin, Vasiliy P.; Sheu, Tiffany G.; Smagala, James; Li, Yan; Klimov, Alexander I.; Gubareva, Larisa V.

    2010-01-01

    Neuraminidase inhibitors (NAIs) are vital in managing seasonal and pandemic influenza infections. NAI susceptibilities of virus isolates (n = 5540) collected during the 2008–2009 influenza season were assessed in the chemiluminescent neuraminidase inhibition (NI) assay. Box-and-whisker plot analyses of log-transformed IC50s were performed for each virus type/subtype and NAI to identify outliers which were characterized based on a statistical cutoff of IC50 >3 interquartile ranges (IQR) from the 75th percentile. Among 1533 seasonal H1N1 viruses tested, 1431 (93.3%) were outliers for oseltamivir; they all harbored the H275Y mutation in the neuraminidase (NA) and were reported as oseltamivir-resistant. Only 15 (0.7%) of pandemic 2009 H1N1 viruses tested (n = 2259) were resistant to oseltamivir. All influenza A(H3N2) (n = 834) and B (n = 914) viruses were sensitive to oseltamivir, except for one A(H3N2) and one B virus, with D151V and D197E (D198E in N2 numbering) mutations in the NA, respectively. All viruses tested were sensitive to zanamivir, except for six seasonal A(H1N1) and several A(H3N2) outliers (n = 22) which exhibited cell culture induced mutations at residue D151 of the NA. A subset of viruses (n = 1058) tested for peramivir were sensitive to the drug, with exception of H275Y variants that exhibited reduced susceptibility to this NAI. This study summarizes baseline susceptibility patterns of seasonal and pandemic influenza viruses, and seeks to contribute towards criteria for defining NAI resistance. PMID:21994620

  16. Field evaluation of a coproantigen detection test for fascioliasis diagnosis and surveillance in human hyperendemic areas of Andean countries.

    Directory of Open Access Journals (Sweden)

    María Adela Valero

    Full Text Available Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA was evaluated, using classical techniques for egg detection for comparison.A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD and infection intensity by eggs per gram of feces (epg in Cajamarca low burden cases (<400 epg, nor in Huacullani high burden cases (≥ 400 epg, although there was in Huacullani low burden cases (<400 epg. Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg.The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase, early detection of treatment failure

  17. Field Evaluation of a Coproantigen Detection Test for Fascioliasis Diagnosis and Surveillance in Human Hyperendemic Areas of Andean Countries

    Science.gov (United States)

    Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago

    2012-01-01

    Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase

  18. Refusal of HIV testing among black Africans attending sexual health clinics in England, 2014: a review of surveillance data.

    Science.gov (United States)

    Mohammed, Hamish; Dabrera, Gavin; Furegato, Martina; Yin, Zheng; Nardone, Anthony; Hughes, Gwenda

    2017-05-01

    Black Africans are one of the key risk groups for HIV in the UK and, among those living with HIV, an estimated 16% and 12% of black African heterosexual men and women, respectively, are undiagnosed and at risk of unknowingly transmitting HIV to their sex partners. Increased HIV test uptake is needed to address this, but there is limited information on how frequently HIV test refusal occurs among those attending sexual health clinics (SHCs). We identified factors associated with HIV test refusal among black African SHC attendees. Data on all SHC attendances in England in 2014 were obtained from the genitourinary medicine clinic activity dataset, the mandatory surveillance system for STIs. Analyses were restricted to attendances by HIV-negative black Africans, and bivariate and multivariable associations between demographic and clinical characteristics and HIV test refusal were assessed. All associations were determined using generalised estimating equations logistic regression, and adjusted ORs (aORs) with 95% CIs are reported. Black Africans made 80 743 attendances at SHCs in 2014 and refused an HIV test on 9021 (11.2%) occasions. HIV test refusal was significantly more likely in women (aOR (95% CI) 1.54 (1.46 to 1.62) vs heterosexual men), and those living in the most deprived areas (1.44 (1.24 to 1.67)), diagnosed with a new STI (1.26 (1.18 to 1.34)) or living in London (1.06 (1.01 to 1.12)). Test refusal was significantly less likely with increasing age (0.99 (0.99 to 0.99)) and men who have sex with men (0.52 (0.43 to 0.63) vs heterosexual men), and in those tested for HIV in the past year (0.85 (0.81 to 0.89)), born outside the UK (0.73 (0.69 to 0.77)) or those attending following partner notification (0.11 (0.03 to 0.38)). Targeted interventions are needed to improve HIV testing uptake and reduce undiagnosed HIV infection among black Africans attending SHCs, especially heterosexuals residing in deprived areas. Published by the BMJ Publishing Group Limited

  19. Results of cytogenetic surveillance of rural populations adjoining to Semipalatinsk test site

    International Nuclear Information System (INIS)

    Abdil'dinova, G.Zh.; Kundakbaeva, G.B.; Zhunusova, A.B.

    1997-01-01

    Purpose of the work is study of somatic cytogenetic effects with taking into consideration chromosomal aberration of population from Beskaragaj district of Semipalatinsk region exposed to influence of conducted nuclear tests on Semipalatinsk test site. Cultures of lymphocyates of peripheral flood were studied. Control group made up 15 man living in Akmola region locating out of radiation contaminated zone. It is determined, that common frequency of chromosomal aberration make up 3.6 on 100 cells. At that frequency of pair fragments made up 2.0 on 100 metaphases (0.2 in control group); dicentrics and center rings were revealed with summary frequency 0.6 on 100 metaphases and that is approximately in 15 fold greater than control index - 0.03 on 100 cells. Stable radiation markers (translocations, deletions) revealed with frequency 1.07 on 100 cells (control make up 0.4 on 100 cells). By results of of conducted cytogenetic analysis the attempt of mean group effective equivalent dose reconstruction received with inhabitants of Beskaragaj district is undertaken. It was calculated, that population of researched district have been got dose loading in 9.09 rem

  20. The effect of the inter-phase delay interval in the spontaneous object recognition test for pigs

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Thygesen, Kristin Sjølie; Nielsen, Thomas Rune

    2007-01-01

    and the familiar object was interpreted as recognition of the familiar object. We scored the exploration times both manually and automatically, and compared the methods. A strong discrimination between novel and familiar objects after a 10-min inter-phase delay interval and no discrimination after 24h were found...

  1. A critical assessment of abattoir surveillance as a screening test for swine ascariasis.

    Science.gov (United States)

    Bernardo, T M; Dohoo, I R; Ogilvie, T

    1990-01-01

    The following data on ascarid burden were collected on an individual basis for 380 hogs marketed in the fall of 1987: a series of fecal ascarid-egg counts during the growing period; the level of milk spot lesions on the liver at slaughter; and the number of ascarids in the small intestines at slaughter. The presence of milk spots had a high sensitivity, very low specificity, and a high negative predictive value as a screening test for ascariasis in individual hogs. Results were consistent whether ascariasis was measured as the presence of intestinal ascarids at slaughter (sensitivity 91%, specificity 22%, negative predictive value 82%), or by a positive fecal egg count during the hog's lifetime (sensitivity 96%, specificity 24%, negative predictive value 93%). The presence of milk spots does not necessarily indicate that an ascarid infection has been established in the small intestine. The absence of milk spots, however, is a reliable indicator of the absence of an established ascarid infection, provided that the prevalence of ascariasis is equal to or less than that observed in this study. The severity of the ascarid infection in an individual hog could not be ascertained by the number of milk spot lesions on the liver. PMID:2357665

  2. Five-Year Risk of Interval-Invasive Second Breast Cancer

    Science.gov (United States)

    Buist, Diana S. M.; Houssami, Nehmat; Dowling, Emily C.; Halpern, Elkan F.; Gazelle, G. Scott; Lehman, Constance D.; Henderson, Louise M.; Hubbard, Rebecca A.

    2015-01-01

    Background: Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. Methods: We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. Results: The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. Conclusions: PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. PMID:25904721

  3. Tigecycline activity tested against antimicrobial resistant surveillance subsets of clinical bacteria collected worldwide (2011).

    Science.gov (United States)

    Sader, Helio S; Flamm, Robert K; Jones, Ronald N

    2013-06-01

    Tigecycline was approved by the United States Food and Drug Administration in 2005 and has generally retained activity against resistant Gram-positive and Gram-negative organisms. We monitored the in vitro activity of this glycylcycline in 2011 for continued potency worldwide. A total of 22,005 unique clinical isolates were consecutively collected in North America (NA; 9232 isolates), Europe (EU; 6776), Latin America (LA; 2016), and Asia-Pacific region (APAC, 3981) and tested for susceptibility according to the reference broth microdilution method recommendations against tigecycline and numerous comparators. Oxacillin (methicillin) resistance rates in methicillin-resistant Staphylococcus aureus (MRSA) were 49.3%, 30.2%, 42.9%, and 37.8%, and vancomycin resistance rates in enterococci (VRE) were 27.0%, 11.3%, 6.3%, and 4.0% in NA, EU, LA, and APAC, respectively. All MRSA (2839) and >99% of VRE were susceptible to tigecycline. Among Escherichia coli, extended-spectrum β-lactamase (ESBL) rates varied from 12.6% in the NA to 57.4% in APAC, and only one strain was nonsusceptible to tigecycline. Tigecycline was active against ESBL phenotype (96.5-98.4% susceptible) and meropenem-nonsusceptible Klebsiella spp. (94.3-100.0% susceptible). Only 4 of 213 (1.9%) meropenem-nonsusceptible Klebsiella spp. were tigecycline-nonsusceptible, all with tigecycline minimum inhibitory concentration (MIC) of 4 μg/mL (intermediate). Among ceftazidime-nonsusceptible Enterobacter spp., 94.7-98.2% were susceptible to tigecycline. Meropenem-nonsusceptible Acinetobacter spp. varied from 51.2% in NA to 80.9% in APAC; and 83.8% (LA) to 93.9% (APAC) of strains were inhibited at a tigecycline MIC of ≤2 μg/mL. Tigecycline showed potent activity against Stenotrophomonas maltophilia (89.3-98.3% inhibited at ≤2 μg/mL). In summary, tigecycline has sustained potent activity and a broad-spectrum against clinically important bacteria causing infections worldwide, including multidrug

  4. Short-interval test-retest interrater reliability of the Dutch version of the structured clinical interview for DSM-IV personality disorders (SCID-II)

    NARCIS (Netherlands)

    Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S

    2003-01-01

    This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The

  5. Establishment of reference intervals of thyroid function tests from cord blood of neonates in two selected hospitals, Addis Ababa, Ethiopia.

    Science.gov (United States)

    Mehari, Aman; Challa, Feyssa; Gebreyesus, Goitom; Alemayehu, Dereje; Seifu, Daniel

    2016-08-02

    Reference intervals are affected by different factors such as lifestyle, ethnicity, age/developmental stage, gender, nutrition and other environmental factors (Clin Biochem Rev: 29,2008). Therefore, it is obvious that it should be established for every population in different regions even within a country. Then the aim of this study is to establish population specific reference intervals of thyroid stimulating hormone, free thyroxine and free triidothyronine levels of cord blood. One hundred twenty three cord blood samples collected from the umbilical cord of newborns were analyzed for thyroid stimulating hormone, free thyroxine and free triidothyronine values. The birth weights ranged between 2500 and 4700 g with mean (SD) value of 3241.46 (459.495) gram. Their gestational age ranged between 37 and 44 weeks with an average of 39.74 weeks. The 2.5(th) and 97.5(th) percentiles of values were found to be 3.48 mIU/L and 27.57 mIU/L for thyroid stimulating hormone, 0.89 ng/dl and 1.53 ng/dl for free thyroxine and 1.19 pg/ml and 2.51 pg/ml for free triidothyronine respectively. In the present study the reference intervals of thyroid stimulating hormone, free thyroxine and free triidothyronine were established and based on the results obtained, were 3.48-27.56 mIU/L for thyroid stimulating hormone, 0.89-1.53 ng/dl for free thyroxine and 1.19-2.51 pg/ml for free triidothyronine. It has been concluded that the result can provide us with an important baseline to establish population specific reference intervals for our country using large scale studies.

  6. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  7. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    Science.gov (United States)

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  8. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  9. Surveillance Pleasures

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    and leisure have not been studied with the same intensity as e.g. policing, civil liberties and social sorting. This paper offers a study of trends in surveillance pleasures, i.e. watching and eavesdropping in popular culture. My focus is the existential aspects and ethical dilemmas of surveillance...

  10. Surveillance Culture

    DEFF Research Database (Denmark)

    2017-01-01

    What does it mean to live in a world full of surveillance? In this documentary film, we take a look at everyday life in Denmark and how surveillance technologies and practices influence our norms and social behaviour. Researched and directed by Btihaj Ajana and Anders Albrechtslund....

  11. New precise value for the muon magnetic moment and sensitive test of the theory of the hfs interval in muonium

    International Nuclear Information System (INIS)

    Casperson, D.E.; Crane, T.W.; Denison, A.B.; Egan, P.O.; Hughes, V.W.; Mariam, F.G.; Orth, H.; Reist, H.W.; Souder, P.A.; Stambaugh, R.D.; Thompson, P.A.; zu Putlitz, G.

    1977-01-01

    Measurements of Zeeman transitions in the ground state of muonium at strong magnetic field have yielded values for the hfs interval, Δν = 4463 302.35(52) kHz (0.12 ppm) and for the muon magnetic moment, μ/sub μ//μ/sub p/ = 3.183 3403(44) (1.4 ppm), fo considerably higher precision than previous results. The theoretical expression for Δν, including our measured value of μ/sub μ//μ/sub p/, disagrees with the experimental value by 2.5 standard deviations. The electronic g/sub J/ density shift for muonium in Kr has been measured

  12. interval functions

    Directory of Open Access Journals (Sweden)

    J. A. Chatfield

    1978-01-01

    Full Text Available Suppose N is a Banach space of norm |•| and R is the set of real numbers. All integrals used are of the subdivision-refinement type. The main theorem [Theorem 3] gives a representation of TH where H is a function from R×R to N such that H(p+,p+, H(p,p+, H(p−,p−, and H(p−,p each exist for each p and T is a bounded linear operator on the space of all such functions H. In particular we show that TH=(I∫abfHdα+∑i=1∞[H(xi−1,xi−1+−H(xi−1+,xi−1+]β(xi−1+∑i=1∞[H(xi−,xi−H(xi−,xi−]Θ(xi−1,xiwhere each of α, β, and Θ depend only on T, α is of bounded variation, β and Θ are 0 except at a countable number of points, fH is a function from R to N depending on H and {xi}i=1∞ denotes the points P in [a,b]. for which [H(p,p+−H(p+,p+]≠0 or [H(p−,p−H(p−,p−]≠0. We also define an interior interval function integral and give a relationship between it and the standard interval function integral.

  13. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M.

    2011-11-01

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm 3 in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  14. Models and procedures for interval evaluating the results of control of knowledge in computer systems testing of Navy

    Directory of Open Access Journals (Sweden)

    D. A. Pechnikov

    2018-01-01

    Full Text Available To implement effective military and professional training of Navy specialists, a corresponding educational and material base is needed. As a result of the reduction in the 1990s in the branches of the military-industrial complex developing weapons and equipment for the Navy, the latest models of this technology are now produced not in batches, but in individual copies. The question of the production of training and training samples is not worth it at all. Under these conditions, only virtual analogues of military equipment and weapons, developed by means of information technology, i.e., training and training systems (TOS, can be considered as the only means capable of providing military-professional training. At the modern level of the development of information technologies, testing is the only universal technical means of monitoring the knowledge of students. Procedures for knowledge control in modern computer testing systems do not meet the requirements for them according to the following characteristics: 1 the absence of the possibility of evaluating the error of the test results; 2 the absence of the possibility of stopping testing when the specified reliability of its results is achieved. In order to effectively implement the means of operational criteria-based pedagogical control of knowledge in the process of training specialists of the Navy and to enable joint analysis and processing of evaluations of learning outcomes, it is advisable to implement the following practical recommendations: 1. Formulating the teacher's preferences system regarding the quality of trainee training and the teacher's preferences system in relation to The significance of single test tasks in the test should be considered as the most important The essential steps in preparing a test for practical use. 2. The teacher who first enters the input of his preference systems should check their actual compliance on a sample of 5-10 such test results that cover the full

  15. Characteristics of patients patch tested in the European Surveillance System on Contact Allergies (ESSCA) network, 2009-2012

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Gefeller, Olaf; Giménez-Arnau, Ana

    2015-01-01

    from 63 530 consultations collected by 53 departments from 12 countries participating in the European Surveillance System on Contact Allergies (ESSCA) ( www.essca-dc.org) between 2009 and 2012. RESULTS: Considerable variation in the prevalence of the MOAHLFA factors between departments was found...... one department per country give valuable insights into the spectrum of contact allergy prevalence rates in that country, but are not as representative as national data pooled from several departments....

  16. Developmental plasticity in fat patterning of Ache children in response to variation in interbirth intervals: a preliminary test of the roles of external environment and maternal reproductive strategies.

    Science.gov (United States)

    Baker, Jack; Hurtado, Ana Magdalena; Pearson, Osbjorn M; Hill, Kim R; Jones, Troy; Frey, M Anderson

    2009-01-01

    A firm link between small size at birth and later more centralized fat patterning has been established in previous research. Relationships between shortened interbirth intervals and small size at birth suggest that maternal energetic prioritization may be an important, but unexplored determinant of offspring fat patterning. Potential adaptive advantages to centralized fat storage (Baker et al., 2008: In: Trevathan W, McKenna J, Smith EO, editors. Evolutionary Medicine and Health: New Perspectives. New York: Oxford) suggest that relationships with interbirth intervals may reflect adaptive responses to variation in patterns of maternal reproductive effort. Kuzawa (2005: Am J Hum Biol 17:5-21; 2008: In: Trevathan W, McKenna J, Smith EO, editors. Evolutionary Medicine and Health: New Perspectives. New York: Oxford) has argued that maternal mediation of the energetic quality of the environment is a necessary component of developmental plasticity models invoking predictive adaptive responses (Gluckman and Hanson 2004: Trends Endocrinol Metab 15:183-187). This study tested the general hypothesis that shortened interbirth intervals would predict more centralized fat patterning in offspring. If long-term maternally mediated signals are important determinants of offspring responses, then we expected to observe a relationship between the average interbirth interval of mothers and offspring adiposity, with no relationship with the preceding interval. Such a finding would suggest that maternal, endogenous resource allocation decisions are related to offspring physiology in a manner consistent with Kuzawa's description. We observed exactly such a relationship among the Ache of Paraguay, suggesting that maternally mediated in utero signals of postnatal environments may be important determinants of later physiology. The implications of these findings are reviewed in light of life history and developmental plasticity theories and ourability to generalize the results to other

  17. Surveillance for Viral Hepatitis - United States, 2014

    Science.gov (United States)

    ... and Programs Resource Center Anonymous Feedback Viral Hepatitis Surveillance for Viral Hepatitis – United States, 2014 Recommend on ... demographic characteristics and laboratory tests – Enhanced Viral Hepatitis Surveillance Sites*, 2014 Category MA No. % MI No. % NYS† ...

  18. Monitoring influenza activity in the United States: a comparison of traditional surveillance systems with Google Flu Trends.

    Directory of Open Access Journals (Sweden)

    Justin R Ortiz

    2011-04-01

    Full Text Available Google Flu Trends was developed to estimate US influenza-like illness (ILI rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections.Influenza activity data from 2003-04 through 2007-08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance, and US Influenza Virologic Surveillance System (CDC Virus Surveillance. Pearson's correlation coefficients with 95% confidence intervals (95% CI were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79. The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89. Most of the outlier observations in both comparisons were from the 2003-04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87 or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90.This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003-04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior.

  19. Monitoring influenza activity in the United States: a comparison of traditional surveillance systems with Google Flu Trends.

    Science.gov (United States)

    Ortiz, Justin R; Zhou, Hong; Shay, David K; Neuzil, Kathleen M; Fowlkes, Ashley L; Goss, Christopher H

    2011-04-27

    Google Flu Trends was developed to estimate US influenza-like illness (ILI) rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections. Influenza activity data from 2003-04 through 2007-08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance), and US Influenza Virologic Surveillance System (CDC Virus Surveillance). Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79). The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89). Most of the outlier observations in both comparisons were from the 2003-04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87) or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90). This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003-04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior.

  20. Monitoring Influenza Activity in the United States: A Comparison of Traditional Surveillance Systems with Google Flu Trends

    Science.gov (United States)

    Ortiz, Justin R.; Zhou, Hong; Shay, David K.; Neuzil, Kathleen M.; Fowlkes, Ashley L.; Goss, Christopher H.

    2011-01-01

    Background Google Flu Trends was developed to estimate US influenza-like illness (ILI) rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections. Methods and Findings Influenza activity data from 2003–04 through 2007–08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance), and US Influenza Virologic Surveillance System (CDC Virus Surveillance). Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79). The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89). Most of the outlier observations in both comparisons were from the 2003–04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87) or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90). Conclusions This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003–04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior. PMID:21556151

  1. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (Capsule 2) of Ulchin Nuclear Power Plant Unit 4

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2007-04-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin Unit 4 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.306E+18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.918 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.615E+18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 8.478E+18 and 1.673E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin Unit 4 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  2. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (CAPSULE 2) of Ulchin Nuclear Power Plant Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2006-12-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.674E 18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.920 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.913E 18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 9.249E 18 and 1.834E 19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  3. Improving the performance of the Egyptian second testing nuclear research reactor using interval type-2 fuzzy logic controller tuned by modified biogeography-based optimization

    Energy Technology Data Exchange (ETDEWEB)

    Sayed, M.M., E-mail: M.M.Sayed@ieee.org; Saad, M.S.; Emara, H.M.; Abou El-Zahab, E.E.

    2013-09-15

    Highlights: • A modified version of the BBO was proposed. • A novel method for interval type-2 FLC design tuned by MBBO was proposed. • The performance of the ETRR-2 was improved by using IT2FLC tuned by MBBO. -- Abstract: Power stabilization is a critical issue in nuclear reactors. The conventional proportional derivative (PD) controller is currently used in the Egyptian second testing research reactor (ETRR-2). In this paper, we propose a modified biogeography-based optimization (MBBO) algorithm to design the interval type-2 fuzzy logic controller (IT2FLC) to improve the performance of the Egyptian second testing research reactor (ETRR-2). Biogeography-based optimization (BBO) is a novel evolutionary algorithm that is based on the mathematical models of biogeography. Biogeography is the study of the geographical distribution of biological organisms. In the BBO model, problem solutions are represented as islands, and the sharing of features between solutions is represented as immigration and emigration between the islands. A modified version of the BBO is applied to design the IT2FLC to get the optimal parameters of the membership functions of the controller. We test the optimal IT2FLC obtained by modified biogeography-based optimization (MBBO) using the integral square error (ISE) and is compared with the currently used PD controller.

  4. Development and interval testing of a naturalistic driving methodology to evaluate driving behavior in clinical research [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Ganesh M. Babulal

    2016-09-01

    Full Text Available Background: The number of older adults in the United States will double by 2056. Additionally, the number of licensed drivers will increase along with extended driving-life expectancy. Motor vehicle crashes are a leading cause of injury and death in older adults. Alzheimer’s disease (AD also negatively impacts driving ability and increases crash risk. Conventional methods to evaluate driving ability are limited in predicting decline among older adults. Innovations in GPS hardware and software can monitor driving behavior in the actual environments people drive in. Commercial off-the-shelf (COTS devices are affordable, easy to install and capture large volumes of data in real-time. However, adapting these methodologies for research can be challenging. This study sought to adapt a COTS device and determine an interval that produced accurate data on the actual route driven for use in future studies involving older adults with and without AD.  Methods: Three subjects drove a single course in different vehicles at different intervals (30, 60 and 120 seconds, at different times of day, morning (9:00-11:59AM, afternoon (2:00-5:00PM and night (7:00-10pm. The nine datasets were examined to determine the optimal collection interval. Results: Compared to the 120-second and 60-second intervals, the 30-second interval was optimal in capturing the actual route driven along with the lowest number of incorrect paths and affordability weighing considerations for data storage and curation. Discussion: Use of COTS devices offers minimal installation efforts, unobtrusive monitoring and discreet data extraction.  However, these devices require strict protocols and controlled testing for adoption into research paradigms.  After reliability and validity testing, these devices may provide valuable insight into daily driving behaviors and intraindividual change over time for populations of older adults with and without AD.  Data can be aggregated over time to look

  5. Surveillance of transmitted HIV drug resistance using matched plasma and dried blood spot specimens from voluntary counseling and testing sites in Ho Chi Minh City, Vietnam, 2007-2008.

    Science.gov (United States)

    Duc, Nguyen Bui; Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-05-01

    During 2007-2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%-15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18-21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs.

  6. Surveillance of Transmitted HIV Drug Resistance Using Matched Plasma and Dried Blood Spot Specimens From Voluntary Counseling and Testing Sites in Ho Chi Minh City, Vietnam, 2007–2008

    Science.gov (United States)

    Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I.; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-01-01

    During 2007–2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%–15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18–21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs. PMID:22544201

  7. Aiding surveillance

    International Development Research Centre (IDRC) Digital Library (Canada)

    arashid

    generator in itself.4 Yet surveillance unconstrained by legal frameworks, human rights protections, and the rule of law has the ... Analysis of the potential adverse implications of using personal information is often completely ..... acknowledge the potential of new information technologies to strengthen electoral processes,.

  8. A 3-year interval is too short for re-screening women testing negative for human papillomavirus: a population-based cohort study.

    Science.gov (United States)

    Zorzi, M; Frayle, H; Rizzi, M; Fedato, C; Rugge, M; Penon, M G; Bertazzo, A; Callegaro, S; Campagnolo, M; Ortu, F; Del Mistro, A

    2017-09-01

    To compare the results from an initial negative human papillomavirus (HPV) test with re-screening after 3 years in women attending two HPV-based screening programmes. Population-based cohort study. Two cervical service screening programmes in Italy. Women aged 25-64 years invited to screening from April 2009 to October 2015. Eligible women were invited to undergo an HPV test. Those with a negative HPV test went on to the next screening round 3 years later. Cytology triage was performed for HPV+ (HPV by Hybrid Capture 2) samples, with immediate colposcopy (if abnormal) and HPV re-testing 1 year later (if negative). Participation rate, positivity at HPV and at triage, referral rate to colposcopy, positive predictive value for cervical intraepithelial neoplasia grade 2+ (CIN2+) at colposcopy, and detection rate for CIN2+. We present the results from 48 751 women at the first screening and 22 000 women at re-screening 3 years later. The response rate was slightly higher at the second screening (74.5 versus 72.1% at the first screening; referral rate, RR 1.11; 95% confidence interval, 95% CI, 1.07-1.14). Compared with the first screening, we observed a significant reduction at the second screening in terms of HPV positivity (RR 0.55, 95% CI 0.51-0.60), referral rate to colposcopy (RR 0.47, 95% CI 0.41-0.53), CIN2+ detection rate (RR 0.24, 95% CI 0.13-0.39), and positive predictive value (PPV) for CIN2+ at colposcopy (RR 0.51, 95% CI 0.29-0.87). The very low frequency of disease and inadequate PPV at colposcopy indicate that a 3-year interval after a negative HPV test is too short. Three years after a negative HPV the frequency of cervical disease is so low that re-screening is inefficient. © 2017 Royal College of Obstetricians and Gynaecologists.

  9. Surveillance of antibiotic resistance

    Science.gov (United States)

    Johnson, Alan P.

    2015-01-01

    Surveillance involves the collection and analysis of data for the detection and monitoring of threats to public health. Surveillance should also inform as to the epidemiology of the threat and its burden in the population. A further key component of surveillance is the timely feedback of data to stakeholders with a view to generating action aimed at reducing or preventing the public health threat being monitored. Surveillance of antibiotic resistance involves the collection of antibiotic susceptibility test results undertaken by microbiology laboratories on bacteria isolated from clinical samples sent for investigation. Correlation of these data with demographic and clinical data for the patient populations from whom the pathogens were isolated gives insight into the underlying epidemiology and facilitates the formulation of rational interventions aimed at reducing the burden of resistance. This article describes a range of surveillance activities that have been undertaken in the UK over a number of years, together with current interventions being implemented. These activities are not only of national importance but form part of the international response to the global threat posed by antibiotic resistance. PMID:25918439

  10. 28 CFR 550.41 - Urine surveillance.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Urine surveillance. 550.41 Section 550.41... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine surveillance. A program of urine testing for drug use shall be established in contract CTCs. (a) Urine...

  11. Simple hyperaemia test as a screening method in the postoperative surveillance of infrainguinal in situ vein bypasses

    DEFF Research Database (Denmark)

    Nielsen, Tina G; Sillesen, H; Schroeder, T V

    1995-01-01

    OBJECTIVES: To develop a simple protocol for ultrasound Duplex surveillance of infrainguinal vein bypasses. DESIGN: The value of three Doppler waveform parameters, obtained from a single point of the bypass, for identification of stenoses was studied in 91 in situ vein bypasses. Midgraft peak...... systolic velocity (PSV), pulsatility index (PI) and ratio of hyperaemic and resting time-average mean velocities (TAMV), (TAMV ratio = TAMVhyperaemia/TAMVrest) were correlated with the presence and severity of stenoses as assessed by conventional Duplex scanning and ankle-brachial index (ABI) measurements....... The optimal value of the waveform parameters for discrimination between bypasses with and without evidence of stenoses was determined by receiver operating characteristics (ROC) analysis. MAIN RESULTS: Complete Duplex scanning of the entire graft revealed an increase in the peak systolic velocity by a factor...

  12. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  13. Health surveillance

    International Nuclear Information System (INIS)

    1981-01-01

    The Code includes a number of requirements for the health surveillance of employees associated with the mining and milling of radioactive ores. This guideline is particularly directed at determining the level of fitness of employees and prospective employees, detecting any symptom which might contraindicate exposure to the environment encountered in mine/mill situations, examination of any employee who may have been exposed to radiation in excess of defined limits and the accumulation and provision of data on the health of employees

  14. Rinderpest surveillance

    International Nuclear Information System (INIS)

    2003-01-01

    Rinderpest is probably the most lethal virus disease of cattle and buffalo and can destroy whole populations; damaging economies; undermining food security and ruining the livelihood of farmers and pastoralists. The disease can be eradicated by vaccination and control of livestock movement. The Department of Technical Co-operation is sponsoring a programme, with technical support from the Joint FAO/IAEA Division to provide advice, training and materials to thirteen states through the 'Support for Rinderpest Surveillance in West Asia' project. (IAEA)

  15. Exploring the utility of cardiorespiratory fitness as a population health surveillance indicator for children and youth: An international analysis of results from the 20-m shuttle run test.

    Science.gov (United States)

    Lang, Justin J

    2018-02-01

    Emerging evidence has demonstrated the strong link between cardiorespiratory fitness and multiple aspects of health (i.e., physiological, physical, psychosocial, cognitive), independent of physical activity, among school-aged children and youth. Cardiorespiratory fitness is a trait that does not vary substantially from day-to-day, and provides an indication of recent physical activity levels, making it an important possible indicator of population health. Thus, the objective of this dissertation was to investigate the utility of cardiorespiratory fitness, measured using the 20-m shuttle run test, as a broad, holistic health indicator for population health surveillance among children and youth. To achieve this objective we completed 7 manuscripts, all prepared for submission to peer-reviewed, scientific journals: (1) Systematic review of the relationship between 20-m shuttle run performance and health indicators among children and youth. (2) Review of criterion-referenced standards for cardiorespiratory fitness: what percentage of 1 142 026 international children and youth are apparently healthy? (3) Cardiorespiratory fitness is associated with physical literacy in a large sample of Canadian children aged 8 to 12 years. (4) International variability in 20-m shuttle run performance in children and youth: Who are the fittest from a 50-country comparison? A systematic review with pooling of aggregate results. (5) Making a case for cardiorespiratory fitness surveillance among children and youth. (6) International normative 20-m shuttle run values from 1 142 026 children and youth representing 50 countries. (7) Temporal trends in the cardiorespiratory fitness of children and adolescents representing 19 high-income and upper middle-income countries between 1981 and 2014. Combined, this dissertation provides support for the importance of cardiorespiratory fitness for health surveillance among school-aged children and youth. Results from the international analysis

  16. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  17. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  18. Testing of an automatic outdoor gamma ambient dose-rate surveillance system in Tokyo and its calibration using measured deposition after the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Zhang, Weihua; Korpach, Ed; Berg, Rodney; Ungar, Kurt

    2013-01-01

    An in-situ fixed point radioactivity surveillance network has been developed at the Radiation Protection Bureau, Health Canada. The network consists of a number of spectrometric NaI(Tl) detectors measuring, in real-time, ambient gamma dose-rate. The present paper describes the gamma dose-rate monitoring by one detector installed at the Canadian embassy in Tokyo during the Fukushima nuclear accident. Soil samples were collected for the measurement of fallout fission products inventories at each location where the NaI(Tl) detector was installed. The gamma-ray attenuation by the soil matrix was estimated by the information on the depth distribution of 137 Cs activities. The study demonstrated that the gamma dose-rates measured by the field NaI(Tl) spectrometric method agreed well with the laboratory results estimated by the inventories of fallout fission products deposited in the soil and the vertical distribution of 137 Cs in the soil. -- Highlights: ► An automatic outdoor gamma ambient dose-rate surveillance system in Tokyo. ► Monitoring of increased ambient gamma dose-rate during the Fukushima accident. ► Laboratory soil sample fallout fission product inventory analysis. ► NaI(Tl) dose-rate calibration coefficient testing by contaminated soil inventories

  19. Surveillance of the environmental radioactivity

    International Nuclear Information System (INIS)

    Schneider, Th.; Gitzinger, C.; Jaunet, P.; Eberbach, F.; Clavel, B.; Hemidy, P.Y.; Perrier, G.; Kiper, Ch.; Peres, J.M.; Josset, M.; Calvez, M.; Leclerc, M.; Leclerc, E.; Aubert, C.; Levelut, M.N.; Debayle, Ch.; Mayer, St.; Renaud, Ph.; Leprieur, F.; Petitfrere, M.; Catelinois, O.; Monfort, M.; Baron, Y.; Target, A.

    2008-01-01

    The objective of these days was to present the organisation of the surveillance of the environmental radioactivity and to allow an experience sharing and a dialog on this subject between the different actors of the radiation protection in france. The different presentations were as follow: evolution and stakes of the surveillance of radioactivity in environment; the part of the European commission, regulatory aspects; the implementation of the surveillance: the case of Germany; Strategy and logic of environmental surveillance around the EDF national centers of energy production; environmental surveillance: F.B.F.C. site of Romans on Isere; steps of the implementation 'analysis for release decree at the F.B.F.C./C.E.R.C.A. laboratory of Romans; I.R.S.N. and the environmental surveillance: situation and perspectives; the part of a non institutional actor, the citizenship surveillance done by A.C.R.O.; harmonization of sampling methods: the results of inter operators G.T. sampling; sustainable observatory of environment: data traceability and samples conservation; inter laboratories tests of radioactivity measurements; national network of environmental radioactivity measurement: laboratories agreements; the networks of environmental radioactivity telemetry: modernization positioning; programme of observation and surveillance of surface environment and installations of the H.A.-M.A.V.L. project (high activity and long life medium activity); Evolution of radionuclides concentration in environment and adaptation of measurements techniques to the surveillance needs; the national network of radioactivity measurement in environment; modes of data restoration of surveillance: the results of the Loire environment pilot action; method of sanitary impacts estimation in the area of ionizing radiations; the radiological impact of atmospheric nuclear tests in French Polynesia; validation of models by the measure; network of measurement and alert management of the atmospheric

  20. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Blood pressure response to isometric handgrip testing and aerobic capacity and associations with sprint performance in middle-aged men following high-intensity interval training.

    Science.gov (United States)

    Zarzeczny, Ryszard; Tomza, Cyprian; Polak, Anna; Nawrat-Szołtysik, Agnieszka

    2018-04-01

    The aim of this study was to determine if a 6-week high-intensity interval training (HIIT) protocol with increasing exercise volume affects aerobic capacity and arterial blood pressure (BP) measured during a fatiguing isometric handgrip test (IHT) in middle-aged, normotensive men and to assess whether sprint performance is associated with training-induced changes in BP. Fourteen recreationally active men (age 43.0±0.9 years, body mass 74.4±2.1 kg, body height 1.74±0.02 m, BMI 24.7±0.5 kg/m2 [mean±SE]) participated in 12 HIIT sessions at an intensity of 85% of heart rate reserve. Sprinting ability was estimated at baseline using the 50-yard dash test (50YDT). Pre- and post-HIIT aerobic capacity and pressor response was assessed by the 12-min Cooper run test (12CT) and the IHT at 30% of maximal voluntary contraction, respectively. Following the intervention, the distance covered in the 12CT and handgrip time to fatigue (HTF) significantly increased (Pperformance (Ptraining-induced ΔBP during IHT are dependent on sprinting ability.

  2. Nutritional surveillance.

    Science.gov (United States)

    Mason, J B; Mitchell, J T

    1983-01-01

    The concept of nutritional surveillance is derived from disease surveillance, and means "to watch over nutrition, in order to make decisions that lead to improvements in nutrition in populations". Three distinct objectives have been defined for surveillance systems, primarily in relation to problems of malnutrition in developing countries: to aid long-term planning in health and development; to provide input for programme management and evaluation; and to give timely warning of the need for intervention to prevent critical deteriorations in food consumption. Decisions affecting nutrition are made at various administrative levels, and the uses of different types of nutritional surveillance information can be related to national policies, development programmes, public health and nutrition programmes, and timely warning and intervention programmes. The information should answer specific questions, for example concerning the nutritional status and trends of particular population groups.Defining the uses and users of the information is the first essential step in designing a system; this is illustrated with reference to agricultural and rural development planning, the health sector, and nutrition and social welfare programmes. The most usual data outputs are nutritional outcome indicators (e.g., prevalence of malnutrition among preschool children), disaggregated by descriptive or classifying variables, of which the commonest is simply administrative area. Often, additional "status" indicators, such as quality of housing or water supply, are presented at the same time. On the other hand, timely warning requires earlier indicators of the possibility of nutritional deterioration, and agricultural indicators are often the most appropriate.DATA COME FROM TWO MAIN TYPES OF SOURCE: administrative (e.g., clinics and schools) and household sample surveys. Each source has its own advantages and disadvantages: for example, administrative data often already exist, and can be

  3. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  4. Development of methodologies for optimization of surveillance testing and maintenance of safety related equipment at NPPs. Report of a research coordination meeting. Working material

    International Nuclear Information System (INIS)

    1997-01-01

    This report summarizes the results of the first meeting of the Coordinated Research Programme (CRP) on Development of Methodologies for Optimization of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs, held at the Agency Headquarters in Vienna, from 16 to 20 December 1996. The purpose of this Research Coordination Meeting (RCM) was that all Chief Scientific Investigators of the groups participating in the CRP presented an outline of their proposed research projects. Additionally, the participants discussed the objective, scope, work plan and information channels of the CRP in detail. Based on these presentations and discussions, the entire project plan was updated, completed and included in this report. This report represents a common agreed project work plan for the CRP. Refs, figs, tabs

  5. Extragenital Gonorrhea and Chlamydia Testing and Infection Among Men Who Have Sex With Men—STD Surveillance Network, United States, 2010–2012

    Science.gov (United States)

    Patton, Monica E.; Kidd, Sarah; Llata, Eloisa; Stenger, Mark; Braxton, Jim; Asbel, Lenore; Bernstein, Kyle; Gratzer, Beau; Jespersen, Megan; Kerani, Roxanne; Mettenbrink, Christie; Mohamed, Mukhtar; Pathela, Preeti; Schumacher, Christina; Stirland, Ali; Stover, Jeff; Tabidze, Irina; Kirkcaldy, Robert D.; Weinstock, Hillard

    2015-01-01

    Background Gonorrhea (GC) and chlamydia (CT) are the most commonly reported notifiable diseases in the United States. The Centers for Disease Control and Prevention recommends that men who have sex with men (MSM) be screened for urogenital GC/CT, rectal GC/CT, and pharyngeal GC. We describe extragenital GC/CT testing and infections among MSM attending sexually transmitted disease (STD) clinics. Methods The STD Surveillance Network collects patient data from 42 STD clinics. We assessed the proportion of MSM attending these clinics during July 2011–June 2012 who were tested and positive for extragenital GC/CT at their most recent visit or in the preceding 12 months and the number of extragenital infections that would have remained undetected with urethral screening alone. Results Of 21 994 MSM, 83.9% were tested for urogenital GC, 65.9% for pharyngeal GC, 50.4% for rectal GC, 81.4% for urogenital CT, 31.7% for pharyngeal CT, and 45.9% for rectal CT. Of MSM tested, 11.1% tested positive for urogenital GC, 7.9% for pharyngeal GC, 10.2% for rectal GC, 8.4% for urogenital CT, 2.9% for pharyngeal CT, and 14.1% for rectal CT. More than 70% of extragenital GC infections and 85% of extragenital CT infections were associated with negative urethral tests at the same visit and would not have been detected with urethral screening alone. Conclusions Extragenital GC/CT was common among MSM attending STD clinics, but many MSM were not tested. Most extragenital infections would not have been identified, and likely would have remained untreated, with urethral screening alone. Efforts are needed to facilitate implementation of extragenital GC/CT screening recommendations for MSM. PMID:24647015

  6. Extragenital gonorrhea and chlamydia testing and infection among men who have sex with men--STD Surveillance Network, United States, 2010-2012.

    Science.gov (United States)

    Patton, Monica E; Kidd, Sarah; Llata, Eloisa; Stenger, Mark; Braxton, Jim; Asbel, Lenore; Bernstein, Kyle; Gratzer, Beau; Jespersen, Megan; Kerani, Roxanne; Mettenbrink, Christie; Mohamed, Mukhtar; Pathela, Preeti; Schumacher, Christina; Stirland, Ali; Stover, Jeff; Tabidze, Irina; Kirkcaldy, Robert D; Weinstock, Hillard

    2014-06-01

    Gonorrhea (GC) and chlamydia (CT) are the most commonly reported notifiable diseases in the United States. The Centers for Disease Control and Prevention recommends that men who have sex with men (MSM) be screened for urogenital GC/CT, rectal GC/CT, and pharyngeal GC. We describe extragenital GC/CT testing and infections among MSM attending sexually transmitted disease (STD) clinics. The STD Surveillance Network collects patient data from 42 STD clinics. We assessed the proportion of MSM attending these clinics during July 2011-June 2012 who were tested and positive for extragenital GC/CT at their most recent visit or in the preceding 12 months and the number of extragenital infections that would have remained undetected with urethral screening alone. Of 21 994 MSM, 83.9% were tested for urogenital GC, 65.9% for pharyngeal GC, 50.4% for rectal GC, 81.4% for urogenital CT, 31.7% for pharyngeal CT, and 45.9% for rectal CT. Of MSM tested, 11.1% tested positive for urogenital GC, 7.9% for pharyngeal GC, 10.2% for rectal GC, 8.4% for urogenital CT, 2.9% for pharyngeal CT, and 14.1% for rectal CT. More than 70% of extragenital GC infections and 85% of extragenital CT infections were associated with negative urethral tests at the same visit and would not have been detected with urethral screening alone. Extragenital GC/CT was common among MSM attending STD clinics, but many MSM were not tested. Most extragenital infections would not have been identified, and likely would have remained untreated, with urethral screening alone. Efforts are needed to facilitate implementation of extragenital GC/CT screening recommendations for MSM.

  7. Results from 15years of quality surveillance for a National Indigenous Point-of-Care Testing Program for diabetes.

    Science.gov (United States)

    Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina

    2017-12-01

    Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Clinical Microbiology Laboratories' Adoption of Culture-Independent Diagnostic Tests Is a Threat to Foodborne-Disease Surveillance in the United States.

    Science.gov (United States)

    Shea, Shari; Kubota, Kristy A; Maguire, Hugh; Gladbach, Stephen; Woron, Amy; Atkinson-Dunn, Robyn; Couturier, Marc Roger; Miller, Melissa B

    2017-01-01

    INTRODUCTIONIn November 2015, the Centers for Disease Control and Prevention (CDC) sent a letter to state and territorial epidemiologists, state and territorial public health laboratory directors, and state and territorial health officials. In this letter, culture-independent diagnostic tests (CIDTs) for detection of enteric pathogens were characterized as "a serious and current threat to public health surveillance, particularly for Shiga toxin-producing Escherichia coli (STEC) and Salmonella" The document says CDC and its public health partners are approaching this issue, in part, by "reviewing regulatory authority in public health agencies to require culture isolates or specimen submission if CIDTs are used." Large-scale foodborne outbreaks are a continuing threat to public health, and tracking these outbreaks is an important tool in shortening them and developing strategies to prevent them. It is clear that the use of CIDTs for enteric pathogen detection, including both antigen detection and multiplex nucleic acid amplification techniques, is becoming more widespread. Furthermore, some clinical microbiology laboratories will resist the mandate to require submission of culture isolates, since it will likely not improve patient outcomes but may add significant costs. Specimen submission would be less expensive and time-consuming for clinical laboratories; however, this approach would be burdensome for public health laboratories, since those laboratories would need to perform culture isolation prior to typing. Shari Shea and Kristy Kubota from the Association of Public Health Laboratories, along with state public health laboratory officials from Colorado, Missouri, Tennessee, and Utah, will explain the public health laboratories' perspective on why having access to isolates of enteric pathogens is essential for public health surveillance, detection, and tracking of outbreaks and offer potential workable solutions which will allow them to do this. Marc Couturier of

  9. Surveillance and Critical Theory

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2015-09-01

    Full Text Available In this comment, the author reflects on surveillance from a critical theory approach, his involvement in surveillance research and projects, and the status of the study of surveillance. The comment ascertains a lack of critical thinking about surveillance, questions the existence of something called “surveillance studies” as opposed to a critical theory of society, and reflects on issues such as Edward Snowden’s revelations, and Foucault and Marx in the context of surveillance.

  10. Characteristics of patients patch tested in the European Surveillance System on Contact Allergies (ESSCA) network, 2009-2012

    NARCIS (Netherlands)

    Uter, Wolfgang; Gefeller, Olaf; Gimenez-Arnau, Ana; Frosch, Peter; Johansen, Jeanne Duus; Schuttelaar, Marie-Louise; Rustemeyer, Thomas; Filon, Francesca Larese; Dugonik, Aleksandra; Bircher, Andreas; Wilkinson, Mark

    BackgroundPatch test results often vary between departments, and also between countries. Such variation may be partly attributable to systematic effects introduced by patient characteristics, differing exposures, patient selection, or methodological differences. ObjectiveTo examine the amount of

  11. Hepatitis C testing and re-testing among people attending sexual health services in Australia, and hepatitis C incidence among people with human immunodeficiency virus: analysis of national sentinel surveillance data.

    Science.gov (United States)

    Boettiger, David C; Law, Matthew G; Dore, Gregory J; Guy, Rebecca; Callander, Denton; Donovan, Basil; O'Connor, Catherine C; Fairley, Christopher K; Hellard, Margaret; Matthews, Gail

    2017-12-01

    Direct acting antivirals are expected to drastically reduce the burden of hepatitis C virus (HCV) in people living with Human Immunodeficiency Virus (HIV). However, rates of HCV testing, re-testing and incident infection in this group remain uncertain in Australia. We assessed trends in HCV testing, re-testing and incident infection among HIV-positive individuals, and evaluated factors associated with HCV re-testing and incident infection. The study population consisted of HIV-positive individuals who visited a sexual health service involved in the Australian Collaboration for Coordinated Enhanced Sentinel Surveillance (ACCESS) between 2007 and 2015. Poisson regression was used to assess trends and to evaluate factors associated with HCV re-testing and incident HCV infection. There were 9227 HIV-positive individuals included in our testing rate analysis. Of 3799 HIV-positive/HCV-negative people that attended an ACCESS sexual health service more than once, 2079 (54.7%) were re-tested for HCV and were therefore eligible for our incidence analysis. The rate of HCV testing increased from 17.1 to 51.4 tests per 100 patient years between 2007 and 2015 (p for trend Australia will assist strategies to achieve HCV elimination through rapid treatment scale up. Continued monitoring of HCV incidence in this population is essential for guiding both HCV prevention and treatment strategies.

  12. Zero- vs. one-dimensional, parametric vs. non-parametric, and confidence interval vs. hypothesis testing procedures in one-dimensional biomechanical trajectory analysis.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2015-05-01

    Biomechanical processes are often manifested as one-dimensional (1D) trajectories. It has been shown that 1D confidence intervals (CIs) are biased when based on 0D statistical procedures, and the non-parametric 1D bootstrap CI has emerged in the Biomechanics literature as a viable solution. The primary purpose of this paper was to clarify that, for 1D biomechanics datasets, the distinction between 0D and 1D methods is much more important than the distinction between parametric and non-parametric procedures. A secondary purpose was to demonstrate that a parametric equivalent to the 1D bootstrap exists in the form of a random field theory (RFT) correction for multiple comparisons. To emphasize these points we analyzed six datasets consisting of force and kinematic trajectories in one-sample, paired, two-sample and regression designs. Results showed, first, that the 1D bootstrap and other 1D non-parametric CIs were qualitatively identical to RFT CIs, and all were very different from 0D CIs. Second, 1D parametric and 1D non-parametric hypothesis testing results were qualitatively identical for all six datasets. Last, we highlight the limitations of 1D CIs by demonstrating that they are complex, design-dependent, and thus non-generalizable. These results suggest that (i) analyses of 1D data based on 0D models of randomness are generally biased unless one explicitly identifies 0D variables before the experiment, and (ii) parametric and non-parametric 1D hypothesis testing provide an unambiguous framework for analysis when one׳s hypothesis explicitly or implicitly pertains to whole 1D trajectories. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The modification and evaluation of an ELISA test for the surveillance of Mycobacterium avium subsp. paratuberculosis infection in wild ruminants

    Directory of Open Access Journals (Sweden)

    Pruvot Mathieu

    2013-01-01

    Full Text Available Abstract Background Enzyme-linked immunosorbent assay (ELISA is often used to test wildlife samples for Mycobacterium avium subsp. paratuberculosis (MAP infection. However, commercially available kits are only validated for use with domestic ruminant species. A literature review was performed to document the current use of MAP serum ELISA in wild and semi-domestic ruminants. We then modified and evaluated a commercial ELISA kit (IDEXX Mycobacterium paratuberculosis Antibody Test Kit for use with species for which it was not originally developed: elk (Cervus elaphus, bison (Bison bison and caribou (Rangifer tarandus. We tested the affinity of different conjugates for immunoglobulin G (IgG isolated from these species, performed checkerboard tests to determine the optimal dilutions of samples and conjugates, and established cut-off values using two different methods: a Receiver Operational Curve on a panel of known samples for elk, and an alternate method involving a panel of unknown serum samples for the three species. Results We found that the anti-bovine conjugate included in the IDEXX ELISA kit has limited affinity for elk, bison, and caribou IgG. Protein G showed good affinity for IgG of all three species, while anti-deer conjugate also bound elk and caribou IgG. Using Protein G with elk serum, a cut-off sample-to-positive (S/P value of 0.22 was selected, resulting in a sensitivity and specificity of 73% and 90%, respectively, whereas, using an anti-deer conjugate with elk serum, an S/P cut-off value of 0.29 gave a sensitivity of 68%, with 100% specificity. Cut-off values for bison and caribou using the Protein G conjugate were 0.17 and 0.25 respectively. Conclusions Due to incomplete reporting and a lack of test validation, it is difficult to critically appraise results of many sero-surveys that have previously been done for MAP in wildlife. Commercial ELISA kits may have limited or no capacity to detect antibodies from species other than for

  14. Relationship between a Centers for Disease Control and Prevention expanded HIV testing initiative and past-year testing by race/ethnicity: a multilevel analysis of the Behavioral Risk Factor Surveillance System.

    Science.gov (United States)

    Gaines, Tommi L; Caldwell, Julia T; Ford, Chandra L; Mulatu, Mesfin S; Godette, Dionne C

    2016-01-01

    The Centers for Disease Control and Prevention's (CDC) expanded testing initiative (ETI) aims to bolster HIV testing among populations disproportionately affected by the HIV epidemic by providing additional funding to health departments serving these communities. ETI prioritizes testing in clinical settings; therefore, we examined the relationship between state-level ETI participation and past-year HIV testing among a racially/ethnically diverse sample of adult respondents to the 2012 Behavioral Risk Factor Surveillance System who accessed health services within the 12 months prior to being interviewed. Controlling for individual- and state-level characteristics in a multilevel logistic regression model, ETI participation was independently and positively associated with past-year testing, but this association varied by race/ethnicity. Hispanics had higher odds (adjusted odds ratio [AOR]: 1.49; 95% CI: 1.11-2.02) and American Indian/Alaska Natives had lower odds (AOR: 0.66; 95% CI: 0.43-0.99) of testing if they resided in states with (vs. without) ETI participation. State-level ETI participation did not significantly alter past-year testing among other racial/ethnic groups. Prioritizing public health resources in states most affected by HIV can improve testing patterns, but other mechanisms likely influence which racial/ethnic groups undergo testing.

  15. Safety of laboratory analyzers for infection testing - results of the market surveillance by the BfArM until end 2007

    Directory of Open Access Journals (Sweden)

    Siekmeier R

    2009-12-01

    Full Text Available Abstract The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM is the responsible CA for most IVD, with a small subset of IVD for immune hematological and infectiological testing as well as tissue typing as specified in Annex II of the Directive, being within the responsibility of the Paul-Ehrlich-Institute (PEI. In this study, all issues regarding laboratory analyzers for infection testing and their consumables, but not reagents, kits and general culture media, reported to the BfArM between begin 1999 and end of 2007 were analyzed in respect to the sources of report, the underlying product failure and the performed corrective actions. Within the observation period a total of 1471 reports for IVD were received of which 73 related to the IVD for infection testing were included in our study. Reports were predominantly received from manufacturers (56 and competent authorities (15. Affected products were most frequently those for immunological analysis (42 whereas those based on culturing techniques (17 and molecular biological techniques (14 played only minor roles. In all these groups, laboratory analyzers (55 were more frequently affected than their consumables (18. Investigations of the manufacturers were able to identify the underlying root causes of product failures in 62 cases (84.9%. In 2 cases (2.7% the root cause remained unclear and in 9 cases (12.3% a product failure was excluded or a user error was the underlying cause. Product failures in laboratory analyzers were most frequently caused by software errors (31 and constructional faults (8 whereas the predominant cause of product failure in consumables were errors in production and

  16. HIV testing and intimate partner violence among non-pregnant women in 15 US states/territories: findings from behavioral risk factor surveillance system survey data.

    Science.gov (United States)

    Nasrullah, Muazzam; Oraka, Emeka; Breiding, Mathew J; Chavez, Pollyanna R

    2013-09-01

    Intimate partner violence (IPV) has been shown to be associated with higher rates of HIV infection among women, underscoring the importance of encouraging IPV victims to receive HIV testing. However, we do not know how much HIV testing behavior is influenced by IPV victimization. The current study characterized the association between individual types of IPV and HIV testing in a large sample of non-pregnant women in 15 US states/territories. The 2005 Behavioral Risk Factor Surveillance System data were analyzed after restricting the sample to non-pregnant women. The dependent variable, whether a woman ever had an HIV test, was examined in relation to individual types of IPV victimization (threatened physical violence; attempted physical violence; completed physical violence; and unwanted sex). Associations between HIV testing and types of IPV were assessed using adjusted risk ratios (aRR) that controlled for demographics and HIV-related risk factors (intravenous drug use, sexually transmitted diseases, exchange sex, unprotected anal sex). Approximately 28.6 % of women reported ever having experienced IPV, and 52.8 % of these women reported being tested for HIV. Among women who had not experienced IPV, 32.9 % reported ever having been tested for HIV. HIV testing was associated with lifetime experience of threatened violence (aRR = 1.43; 95 % CI = 1.24-1.65), attempted violence (aRR = 1.43; 95 % CI = 1.20-1.69), completed physical violence (aRR = 1.30; 95 % CI = 1.13-1.48), and unwanted sex (aRR = 1.66; 95 % CI = 1.48-1.86). Women who experienced each type of IPV were more likely to have been ever tested for HIV compared to women with no IPV history. However, nearly half of those reporting IPV, even though at greater risk for HIV infection, had never been tested. Additional efforts are needed to address barriers to testing in this group.

  17. [Active surveillance of prostate cancer].

    Science.gov (United States)

    Ploussard, G; Hennequin, C; Rozet, F

    2017-10-01

    Several prospective studies have demonstrated the safety of active surveillance as a first treatment of prostate cancer. It spares many patients of a useless treatment, with its potential sequelae. Patients with a low-risk cancer are all candidates for this approach, as recommended by the American Society of Clinical Oncology (ASCO). Some patients with an intermediate risk could be also concerned by active surveillance, but this is still being discussed. Currently, the presence of grade 4 lesions on biopsy is a contra-indication. Modalities included a repeated prostate specific antigen test and systematic rebiopsy during the first year after diagnosis. MRI is now proposed to better select patients at inclusion and also during surveillance. No life style changes or drugs are significantly associated with a longer duration of surveillance. Copyright © 2017. Published by Elsevier SAS.

  18. Reuse fo a Cold War Surveillance Drone to Flight Test a NASA Rocket Based Combined Cycle Engine

    Science.gov (United States)

    Brown, T. M.; Smith, Norm

    1999-01-01

    Plans for and early feasibility investigations into the modification of a Lockheed D21B drone to flight test the DRACO Rocket Based Combined Cycle (RBCC) engine are discussed. Modifications include the addition of oxidizer tanks, modern avionics systems, actuators, and a vehicle recovery system. Current study results indicate that the D21B is a suitable candidate for this application and will allow demonstrations of all DRACO engine operating modes at Mach numbers between 0.8 and 4.0. Higher Mach numbers may be achieved with more extensive modification. Possible project risks include low speed stability and control, and recovery techniques.

  19. Who is Surveilling Whom?

    DEFF Research Database (Denmark)

    Mortensen, Mette

    2014-01-01

    This article concerns the particular form of counter-surveillance termed “sousveillance”, which aims to turn surveillance at the institutions responsible for surveillance. Drawing on the theoretical perspectives “mediatization” and “aerial surveillance,” the article studies WikiLeaks’ publication...

  20. Convex Interval Games

    NARCIS (Netherlands)

    Alparslan-Gok, S.Z.; Brânzei, R.; Tijs, S.H.

    2008-01-01

    In this paper, convex interval games are introduced and some characterizations are given. Some economic situations leading to convex interval games are discussed. The Weber set and the Shapley value are defined for a suitable class of interval games and their relations with the interval core for

  1. Interval algebra - an effective means of scheduling surveillance radar networks

    CSIR Research Space (South Africa)

    Focke, RW

    2015-05-01

    Full Text Available -term planning is desirable, there is still work required to make these practically feasible in all cases. There are various architectures used for creating a mulstisensor man- 3 ager. Traditionally, a centralised architecture has been used, where a central... in the timeline of sensing actions for each sensor. This is known as the scheduling function, which is the focus of this work. A sensor coordination algorithm is considered a nimble scheduler when it is able to rapidly adapt to changes in the surveyed area...

  2. Cooperative interval games

    OpenAIRE

    Bok, Jan

    2014-01-01

    In this thesis, we study cooperative interval games, a generalized model of cooperative games in which worth of every coalition corresponds with a closed interval representing all possible outcomes of their cooperation. We give a brief introduction into classical cooperative games, interval analysis and finally introduction to cooperative interval games with focus on selections, that is on all possible outcomes of interval game with no additional uncertainty. We introduce new selection-based ...

  3. Ceftazidime-avibactam and comparator agents tested against urinary tract isolates from a global surveillance program (2011).

    Science.gov (United States)

    Flamm, Robert K; Sader, Helio S; Farrell, David J; Jones, Ronald N

    2014-11-01

    Ceftazidime-avibactam, a combination of ceftazidime and the non-β-lactam β-lactamase inhibitor avibactam, is in advanced clinical development. In this study, we report results of in vitro testing of ceftazidime-avibactam and comparator agents against a collection of urinary tract infection (UTI) isolates from the United States (USA), Europe and Mediterranean region (EMR), Latin America (LATAM), and the Asia-Pacific/South Africa regions (APAC). Clinical isolates (1 per patient episode) were collected from patients with a UTI during 2011. A total of 1797 isolates were collected from 159 medical centers. Isolates were processed at the medical centers and forwarded to a central monitoring laboratory for confirmatory identification and reference susceptibility testing. Ceftazidime-avibactam was highly active against Enterobacteriaceae and Pseudomonas aeruginosa. The MIC90 values for ceftazidime-avibactam against Enterobacteriaceae in the USA, EMR, and LATAM regions ranged from 0.25 to 0.5μg/mL. The MIC90 in the APAC was slightly elevated at 1μg/mL. A total of 6.1% (8/131) of Escherichia coli in the USA, 23.5% (43/183) in the EMR, 61.2% (30/49) in LATAM, and 75.0% (9/12) in APAC exhibited an extended-spectrum β-lactamase (ESBL) screen-positive phenotype. A total of 1.6% (2/129) of Klebsiella pneumoniae isolates in the USA were meropenem-non-susceptible (MIC ≥2μg/mL), but a rate of 10.3% (10/97) was observed in the EMR. All ESBL screen-positive phenotype and meropenem-non-susceptible E. coli and K. pneumoniae isolates exhibited a ceftazidime-avibactam MIC ≤4μg/mL. All isolates of P. aeruginosa in the USA and 80.9% (38/47) in the EMR were inhibited at a ceftazidime-avibactam MIC of ≤8μg/mL compared to 88.2% (15/17) and 61.7% (29/47) for ceftazidime alone. Ceftazidime-avibactam demonstrated wide in vitro activity against Gram-negative bacteria from patients with UTI including high potencies against multidrug-resistant organisms. Copyright © 2014 Elsevier Inc

  4. Location-based HIV behavioural surveillance among MSM in Auckland, New Zealand 2002-2011: condom use stable and more HIV testing.

    Science.gov (United States)

    Saxton, Peter J W; Dickson, Nigel P; Hughes, Anthony J

    2014-03-01

    Over the last decade, annual HIV diagnoses among men who have sex with men (MSM) in New Zealand increased, then stabilised in 2006 and have not increased further. The aim was to examine trends in behaviours in order to better understand this pattern and inform community-based prevention. From 2002 to 2011, we conducted five repeat cross-sectional behavioural surveillance surveys among MSM at community locations in Auckland (fair day, gay bars, sex-on-site venues; n=6091). Participation was anonymous and self-completed. Recruitment methods were consistent at each round. Overall, the samples became more ethnically diverse and less gay community attached over time. Condom use during anal intercourse was stable across three partnering contexts (casual, current regular fuckbuddy, current regular boyfriend), with a drop among casual contacts in 2011 only. In the 6 months prior to surveys, there was a gradual decline over time in the proportion reporting >20 male partners, an increase in acquiring partners from the internet and increases in engagement in anal intercourse in some partnering contexts. HIV testing in the 12 months prior to surveys rose from 35.1% in 2002 to 50.4% in 2011, mostly from 2008. This first indepth examination of trends in HIV-related behaviours among five consecutive large and diverse samples of MSM in New Zealand does not suggest condom use is declining. However, subtle changes in sexual networks and partnering may be altering the epidemic determinants in this population and increasing exposure.

  5. Visual interface for the automation of the instrumented pendulum of Charpy tests used in the surveillance program of reactors vessel of nuclear power plants

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Sainz M, E.; Ruiz E, J.A.

    2004-01-01

    Inside the Programs of Surveillance of the nuclear power stations periodic information is required on the state that keep the materials with those that builds the vessel of the reactor. This information is obtained through some samples or test tubes that are introduced inside the core of the reactor and it is observed if its physical characteristics remain after having been subjected to the radiation changes and temperature. The rehearsal with the instrumented Charpy pendulum offers information on the behavior of fracture dynamics of a material. In the National Institute of Nuclear Research (ININ) it has an instrumented Charpy pendulum. The operation of this instrument is manual, having inconveniences to carry out rehearsals with radioactive material, handling of high and low temperatures, to fulfill the normative ones for the realization of the rehearsals, etc. In this work the development of a computational program is presented (virtual instrument), for the automation of the instrumented pendulum. The system has modules like: Card of data acquisition, signal processing, positioning system, tempered system, pneumatic system, compute programs like it is the visual interface for the operation of the instrumented Charpy pendulum and the acquisition of impact signals. This system shows that given the characteristics of the nuclear industry with radioactive environments, the virtual instrumentation and the automation of processes can contribute to diminish the risks to the personnel occupationally exposed. (Author)

  6. 40 CFR 52.533 - Source surveillance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Source surveillance. 52.533 Section 52.533 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Florida § 52.533 Source surveillance. The plan lacks test...

  7. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning; Otimizacao aplicada ao planejamento de politicas de testes em sistemas nucleares por enxame de particulas

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Newton Norat

    2006-12-15

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  8. Antenatal Surveillance in Twin Pregnancies Using the Biophysical Profile.

    Science.gov (United States)

    Booker, Whitney; Fox, Nathan S; Gupta, Simi; Carroll, Rachel; Saltzman, Daniel H; Klauser, Chad K; Rebarber, Andrei

    2015-11-01

    Objectives-The nonstress test is currently the most widely used modality for antenatal surveillance in twin pregnancies, with a quoted false-positive rate of 11%-12%. Our objective was to report our experience with the sonographic portion of the biophysical profile in twin pregnancies as the primary screening modality.Methods-Women with twin pregnancies delivered by a single maternal-fetal medicine practice from 2005 to 2013 were included. We excluded monoamniotic twins. Twin pregnancies began weekly sonography for the biophysical profile starting at 32 to 33 weeks, or earlier if indicated. The nonstress test was performed if the sonographic biophysical profile score was less than 8 of 8. We reviewed biophysical profile scores and outcomes for all patients who delivered at 33 weeks or later to assess the false-positive rate for the biophysical profile, as well as the incidence of intrauterine fetal death (IUFD) after initiation of antenatal surveillance.Results-A total of 539 twin pregnancies were included. The incidence of IUFD per patient was 2 per 539 (0.4%; 95% confidence interval [CI], 0.1%-1.3%), and the incidence of IUFD per fetus was 2 per 1078 (0.19%; 95% CI, 0.05%-0.7%). The overall positive screen rate was 24 per 539 (4.45%; 95% CI, 3.0%-6.5%). The false-positive screen rate, defined as an abnormal biophysical profile that did not diagnose an IUFD or lead to delivery, was 10 per 539 (1.9%; 95% CI, 1.0%-3.4%).Conclusions-In twin pregnancies the use of the sonographic biophysical profile for routine antenatal surveillance has a low false-positive rate, with a very low incidence of IUFD. The sonographic biophysical profile should be considered as a primary mode for antenatal surveillance in twin pregnancies, with a reflex nonstress test for an abnormal score. © 2015 by the American Institute of Ultrasound in Medicine.

  9. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  10. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  11. Outcome of 24 years national surveillance in different hereditary colorectal cancer subgroups leading to more individualised surveillance.

    Science.gov (United States)

    Lindberg, Lars Joachim; Ladelund, Steen; Frederiksen, Birgitte Lidegaard; Smith-Hansen, Lars; Bernstein, Inge

    2017-05-01

    Individuals with hereditary non-polyposis colorectal cancer (HNPCC) have a high risk of colorectal cancer (CRC). The benefits of colonic surveillance in Lynch syndrome and Amsterdam-positive (familial CRC type X familial colorectal cancer type X (FCCTX)) families are clear; only the interval between colonoscopies is debated. The potential benefits for families not fulfilling the Amsterdam criteria are uncertain. The aim of this study was to compare the outcome of colonic surveillance in different hereditary subgroups and to evaluate the surveillance programmes. A prospective, observational study on the outcome of colonic surveillance in different hereditary subgroups based on 24 years of surveillance data from the national Danish HNPCC register. We analysed 13 444 surveillance sessions, including 8768 incidence sessions and 20 450 years of follow-up. CRC was more incident in the Lynch subgroup (2.0%) than in any other subgroup (0.0-0.4%, psurveillance. We suggest less frequent and more individualised surveillance in non-Lynch families. Individuals from families with a strong history of CRC could be offered 5-year surveillance colonoscopies (unless findings at the preceding surveillance session indicate shorter interval) and individuals from moderate-risk families could be handled with the population-based screening programme for CRC after an initial surveillance colonoscopy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  13. Interval Temporal Logics

    DEFF Research Database (Denmark)

    Monica, Dario Della; Goranko, Valentin; Montanari, Angelo

    2011-01-01

    We discuss a family of modal logics for reasoning about relational structures of intervals over (usually) linear orders, with modal operators associated with the various binary relations between such intervals, known as Allen’s interval relations. The formulae of these logics are evaluated...... at intervals rather than points and the main eect of that semantic feature is substantially higher expressiveness and computational complexity of the interval logics as compared to point-based ones. Without purporting to provide a comprehensive survey of the field, we take the reader to a journey through...... the main developments in it over the past 10 years and outline some landmark results on expressiveness and (un)decidability of the satisfiability problem for the family of interval logics....

  14. The Development and Pilot Testing of the Marijuana Retail Surveillance Tool (MRST): Assessing Marketing and Point-of-Sale Practices among Recreational Marijuana Retailers

    Science.gov (United States)

    Berg, Carla J.; Henriksen, Lisa; Cavazos-Rehg, Patricia; Schauer, Gillian L.; Freisthler, Bridget

    2017-01-01

    As recreational marijuana expands, it is critical to develop standardized surveillance measures to study the retail environment. To this end, our research team developed and piloted a tool assessing recreational marijuana retailers in a convenience sample of 20 Denver retailers in 2016. The tool assesses: (i) compliance and security (e.g.…

  15. Between visibility and surveillance

    DEFF Research Database (Denmark)

    Uldam, Julie

    As activists move from alternative media platforms to commercial social media platforms they face increasing challenges in protecting their online security and privacy. While government surveillance of activists is well-documented in both scholarly research and the media, corporate surveillance...... of activists remains under-researched. This presentation explores visibility as a prerequisite and an obstacle to political participation. The dual capacity of visibility in social media enables both surveillance and counter-surveillance by making not only the surveilled actor, but also the surveilling actor...... visible. It thus enables activists to monitor and expose corporate misconduct, but simultaneously renders them vulnerable to surveillance from corporations. In this presentation, I examine these practices and discuss their implications for political participation by drawing on examples of companies...

  16. Surveillance and Communication

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Albrechtslund, Anders; Lauritsen, Peter

    2017-01-01

    eyes of cameras are but one of many important aspects of the surveillance society. In particular, surveillance has become intrinsic to our digitally mediated communication. Many are constantly engaged in forms of social surveillance as they observe what friends, family, celebrities, love interests......, and acquaintances are up to on social media. In turn, they also leave trails of digital footprints that may be collected and analyzed by governments, businesses, or hackers. The imperceptible nature of this new surveillance raises some pressing concerns about our digital lives as our data doubles increasingly...... are particularly relevant to this topic and audience. The fourth section outlines a variety of themes in which surveillance of communication is being studied. Organized under the headings Tracking; Mass Surveillance; Media; and Art, Fiction, and Popular Culture, this section provides a survey in surveillance...

  17. Robust misinterpretation of confidence intervals

    NARCIS (Netherlands)

    Hoekstra, Rink; Morey, Richard; Rouder, Jeffrey N.; Wagenmakers, Eric-Jan

    2014-01-01

    Null hypothesis significance testing (NHST) is undoubtedly the most common inferential technique used to justify claims in the social sciences. However, even staunch defenders of NHST agree that its outcomes are often misinterpreted. Confidence intervals (CIs) have frequently been proposed as a more

  18. A Radiation-Triggered Surveillance System for UF6 Cylinder Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Michael M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myjak, Mitchell J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-23

    This report provides background information and representative scenarios for testing a prototype radiation-triggered surveillance system at an operating facility that handles uranium hexafluoride (UF6) cylinders. The safeguards objective is to trigger cameras using radiation, or radiation and motion, rather than motion alone, to reduce significantly the number of image files generated by a motion-triggered system. The authors recommend the use of radiation-triggered surveillance at all facilities where cylinder paths are heavily traversed by personnel. The International Atomic Energy Agency (IAEA) has begun using surveillance cameras in the feed and withdrawal areas of gas centrifuge enrichment plants (GCEPs). The cameras generate imagery using elapsed time or motion, but this creates problems in areas occupied 24/7 by personnel. Either motion-or-interval-based triggering generates thousands of review files over the course of a month. Since inspectors must review the files to verify operator material-flow-declarations, a plethora of files significantly extends the review process. The primary advantage of radiation-triggered surveillance is the opportunity to obtain full-time cylinder throughput verification versus what presently amounts to part-time verification. Cost savings should be substantial, as the IAEA presently uses frequent unannounced inspections to verify cylinder-throughput declarations. The use of radiation-triggered surveillance allows the IAEA to implement less frequent unannounced inspections for the purpose of flow verification, but its principal advantage is significantly shorter and more effective inspector video reviews.

  19. Thermal surveillance of volcanoes

    Science.gov (United States)

    Friedman, J. D. (Principal Investigator)

    1972-01-01

    The author has identified the following significant results. A systematic aircraft program to monitor changes in the thermal emission from volcanoes of the Cascade Range has been initiated and is being carried out in conjunction with ERTS-1 thermal surveillance experiments. Night overflights by aircraft equipped with thermal infrared scanners sensitive to terrestrial emission in the 4-5.5 and 8-14 micron bands are currently being carried out at intervals of a few months. Preliminary results confirm that Mount Rainier, Mount Baker, Mount Saint Helens, Mount Shasta, and the Lassen area continue to be thermally active, although with the exception of Lassen which erupted between 1914 and 1917, and Mount Saint Helens which had a series of eruptions between 1831 and 1834, there has been no recent eruptive activity. Excellent quality infrared images recorded over Mount Rainier, as recently as April, 1972, show similar thermal patterns to those reported in 1964-1966. Infrared images of Mount Baker recorded in November 1970 and again in April 1972 revealed a distinct array of anomalies 1000 feet below the crater rim and associated with fumaroles or structures permitting convective heat transfer to the surface.

  20. HIV infection and risk, prevention, and testing behaviors among injecting drug users -- National HIV Behavioral Surveillance System, 20 U.S. cities, 2009.

    Science.gov (United States)

    Broz, Dita; Wejnert, Cyprian; Pham, Huong T; DiNenno, Elizabeth; Heffelfinger, James D; Cribbin, Melissa; Krishna, Nevin; Teshale, Eyasu H; Paz-Bailey, Gabriela

    2014-07-04

    At the end of 2009, an estimated 1,148,200 persons aged ≥13 years were living with human immunodeficiency virus (HIV) infection in the United States. Despite the recent decreases in HIV infection attributed to injection drug use, 8% of new HIV infections in 2010 occurred among injecting drug users (IDUs). June-December 2009. The National HIV Behavioral Surveillance System (NHBS) collects HIV prevalence and risk behavior data in selected metropolitan statistical areas (MSAs) from three populations at high risk for HIV infection: men who have sex with men, IDUs, and heterosexual adults at increased risk for HIV infection. Data for NHBS are collected in rotating cycles. For the 2009 NHBS cycle, IDUs were recruited in 20 participating MSAs using respondent-driven sampling, a peer-referral sampling method. Participants were eligible if they were aged ≥18 years, lived in a participating MSA, were able to complete a behavioral survey in English or Spanish, and reported that they had injected drugs during the past 12 months. Consenting participants completed an interviewer-administered (face-to-face), anonymous standardized questionnaire about HIV-associated behaviors, and all participants were offered anonymous HIV testing. Analysis of 2009 NHBS data represents the first large assessment of HIV prevalence among IDUs in the United States in >10 years. This report summarizes two separate analyses using unweighted data from 10,200 eligible IDUs in 20 MSAs from the second collection cycle of NHBS in 2009. Both an HIV infection analysis and a behavioral analysis were conducted. Different denominators were used in each analysis because of the order and type of exclusion criteria applied. For the HIV infection analysis, of the 10,200 eligible participants, 10,090 had a valid HIV test result, of whom 906 (9%) tested positive for HIV (range: 2%-19% by MSA). When 509 participants who reported receiving a previous positive HIV test result were excluded from this analysis, 4

  1. Estimating duration intervals

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); B.L.K. Vroomen (Björn)

    2003-01-01

    textabstractDuration intervals measure the dynamic impact of advertising on sales. More precise, the p per cent duration interval measures the time lag between the advertising impulse and the moment that p per cent of its effect has decayed. In this paper, we derive an expression for the duration

  2. Mechanical surveillance of French PWR's

    International Nuclear Information System (INIS)

    Puyal, C.; Brillon, A.; Aupied, J.; Bernard, P.; Carre, J.C.; Epstein, A.

    1981-08-01

    It is expected that, by the end of 1986, almost forty 900 MWe nuclear power plants would be operating in France. In order to increase their availability, a surveillance has been set from the startup of the first unit Fessenheim 1. Mechanical surveillance is only considered here, that is, the surveillance of internal structures vibrations, and the detection of loose parts. The surveillance of vibrations aims to detect an anomaly in internals vibratory behaviour. For that, signals are used from accelerometers located on the pressure vessel and from ex core ion chambers. Signatures of these signals (Power Spectral Densities) are obtained periodically on site and automatically compared with the initial reference signature. Their interpretation is based on theoretical and experimental studies. Early detection of loose parts also is important to maintain the integrity of internal structures. We use the impulses obtained by accelerometers located on the primary circuit, due to shocks of metallic parts and surface wave propagation. Tests have been performed on site to determine the system sensitivity: the detection of a loose part inside a steam generator hot box during the preoperational test and the malfunction of a valve. Now, the progressive commissioning of new 900 and 1300 MWe nuclear power plants has lead us to automatize on site anomaly detection, in order to reduce the operator's work. Other developments are being carried out, such as the realization of specific devices, the development of a data bank, including data from each reactor, from each family of identical reactors and data related to particular incidents

  3. Haemostatic reference intervals in pregnancy

    DEFF Research Database (Denmark)

    Szecsi, Pal Bela; Jørgensen, Maja; Klajnbard, Anna

    2010-01-01

    Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age......-specific reference intervals for coagulation tests during normal pregnancy. Eight hundred one women with expected normal pregnancies were included in the study. Of these women, 391 had no complications during pregnancy, vaginal delivery, or postpartum period. Plasma samples were obtained at gestational weeks 13...

  4. Adherence to physician recommendations for surveillance in opportunistic colorectal cancer screening: the necessity of organized surveillance.

    Directory of Open Access Journals (Sweden)

    Christian Stock

    Full Text Available BACKGROUND: Limited evidence exists on the utilization of surveillance colonoscopy in colorectal cancer (CRC screening programs. We assessed adherence to physician recommendations for surveillance in opportunistic CRC screening in Germany. METHODS: A follow-up study of screening colonoscopy participants in 2007-2009 in Saarland, Germany, was conducted using health insurance claims data. Utilization of additional colonoscopies through to 2011 was ascertained. Adherence to surveillance intervals of 3, 6, 12 and 36 months, defined as having had colonoscopy at 2.5 to 4, 5 to 8, 10.5 to 16 and 33 to 48 months, respectively (i.e., tolerating a delay of 33% of each interval was assessed. Potential predictors of non-adherence were investigated using logistic regression analysis. RESULTS: A total of 20,058 screening colonoscopy participants were included in the study. Of those with recommended surveillance intervals of 3, 6, 12 and 36 months, 46.5% (95%-confidence interval [CI]: 37.3-55.7%, 38.5% (95%-CI: 29.6-47.3%, 25.4% (95%-CI: 21.2-29.6% and 28.0% (95%-CI: 25.5-30.5%, respectively, had a subsequent colonoscopy within the specified margins. Old age, longer recommended surveillance interval, not having had polypectomy at screening and negative colonoscopy were statistically significant predictors of non-adherence. CONCLUSION: This study suggests frequent non-adherence to physician recommendations for surveillance colonoscopy in community practice. Increased efforts to improve adherence, including introduction of more elements of an organized screening program, seem necessary to assure a high-quality CRC screening process.

  5. Adherence to colorectal polyp surveillance guidelines: is there a 'scope' to increase the opportunities for screening?

    LENUS (Irish Health Repository)

    O'Connor, Anthony

    2012-02-01

    Colorectal polyps are usually asymptomatic and are found opportunistically. Individuals with adenomata are at increased risk for cancer and therefore guidelines exist for surveillance of these lesions including those of the British Society of Gastroenterology (BSG). Deviation from these guidelines is common and increases the workload of endoscopy. We examined those individuals waiting for endoscopy for polyp surveillance to see whether strict adherence to BSG guidelines could facilitate opportunities for screening. A total of 413 patients with earlier colonic polyps were examined, of whom 50 patients were excluded based on having alternative indications for surveillance, 179 (49.3%) were appropriately scheduled for surveillance and 184 patients (55.9%) were scheduled incorrectly. Seventy-nine patients (30%) could have been discharged; of these, 59 had hyperplastic polyps. Of the remaining 105 inappropriate triages under surveillance at the wrong interval, seven patients were scheduled for too infrequent surveillance and 98 were too frequent. A total of 284 patients with adenomatous polyps were under surveillance of whom 11 patients (3.8%) were in the high-risk category and all were appropriately scheduled, and 75 patients (26.4%) were in the intermediate-risk category, of whom 48 were appropriately scheduled, 20 were incorrectly triaged as high risk and seven were triaged as low risk. A total of 198 (69.7%) patients were in the low-risk category, 117 of these were correctly triaged, 15 were incorrectly triaged as high risk and 66 were classified as intermediate risk. Over a five-year period, 318 unnecessary colonoscopies are being performed. On the basis of the data obtained from a population-based colorectal screening programme using immunohistochemical-faecal occult blood testing in our department another 1516 patients could be screened annually without requiring any additional endoscopy resources, if strict adherence to guidelines was assured.

  6. Digitally Available Interval-Specific Rock-Sample Data Compiled from Historical Records, Nevada Test Site and Vicinity, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    David B. Wood

    2009-10-08

    Between 1951 and 1992, underground nuclear weapons testing was conducted at 828 sites on the Nevada Test Site, Nye County, Nevada. Prior to and following these nuclear tests, holes were drilled and mined to collect rock samples. These samples are organized and stored by depth of borehole or drift at the U.S. Geological Survey Core Library and Data Center at Mercury, Nevada, on the Nevada Test Site. From these rock samples, rock properties were analyzed and interpreted and compiled into project files and in published reports that are maintained at the Core Library and at the U.S. Geological Survey office in Henderson, Nevada. These rock-sample data include lithologic descriptions, physical and mechanical properties, and fracture characteristics. Hydraulic properties also were compiled from holes completed in the water table. Rock samples are irreplaceable because pre-test, in-place conditions cannot be recreated and samples cannot be recollected from the many holes destroyed by testing. Documenting these data in a published report will ensure availability for future investigators.

  7. Digitally Available Interval-Specific Rock-Sample Data Compiled from Historical Records, Nevada Test Site and Vicinity, Nye County, Nevada.

    Energy Technology Data Exchange (ETDEWEB)

    David B. Wood

    2007-10-24

    Between 1951 and 1992, 828 underground tests were conducted on the Nevada Test Site, Nye County, Nevada. Prior to and following these nuclear tests, holes were drilled and mined to collect rock samples. These samples are organized and stored by depth of borehole or drift at the U.S. Geological Survey Core Library and Data Center at Mercury, Nevada, on the Nevada Test Site. From these rock samples, rock properties were analyzed and interpreted and compiled into project files and in published reports that are maintained at the Core Library and at the U.S. Geological Survey office in Henderson, Nevada. These rock-sample data include lithologic descriptions, physical and mechanical properties, and fracture characteristics. Hydraulic properties also were compiled from holes completed in the water table. Rock samples are irreplaceable because pre-test, in-place conditions cannot be recreated and samples cannot be recollected from the many holes destroyed by testing. Documenting these data in a published report will ensure availability for future investigators.

  8. Reassembling Surveillance Creep

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Lauritsen, Peter

    2017-01-01

    We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical...... development or in empirical analyses. Accordingly, this article contributes to this special issue on the usefulness of Actor-Network Theory (ANT) by suggesting that ANT can advance our understanding of ‘surveillance creep’. Based on ANT’s model of translation and a historical study of the Danish DNA database......, we argue that surveillance creep involves reassembling the relations in surveillance networks between heterogeneous actors such as the watchers, the watched, laws, and technologies. Second, surveillance creeps only when these heterogeneous actors are adequately interested and aligned. However...

  9. Handbook of surveillance technologies

    CERN Document Server

    Petersen, JK

    2012-01-01

    From officially sanctioned, high-tech operations to budget spy cameras and cell phone video, this updated and expanded edition of a bestselling handbook reflects the rapid and significant growth of the surveillance industry. The Handbook of Surveillance Technologies, Third Edition is the only comprehensive work to chronicle the background and current applications of the full-range of surveillance technologies--offering the latest in surveillance and privacy issues.Cutting-Edge--updates its bestselling predecessor with discussions on social media, GPS circuits in cell phones and PDAs, new GIS s

  10. Redefining syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Rebecca Katz

    2011-12-01

    Full Text Available With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field’s capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries.

  11. Surveillance Avoidance Technique Demonstration.

    Science.gov (United States)

    1983-12-02

    path and, using the evaluation module for feedback , alter the path until acceptable surveil- lance avoidance performance is achieved. The current ISAS...Nmber Diselav Stage Containing - Date: I I Time ( GIlT ): Figure 3-46: Textual Display for GRAPHICAL Module 3-64 Surveillance Avoidance Final Report System

  12. Test-retest reproducibility of elbow goniometric measurements in a rigid double-blinded protocol: intervals for distinguishing between measurement error and clinical change.

    Science.gov (United States)

    Cleffken, Berry; van Breukelen, Gerard; van Mameren, Henk; Brink, Peter; Olde Damink, Steven

    2007-01-01

    Increasingly, goniometry of elbow motion is used for qualification of research results. Expression of reliability is in parameters not suitable for comparison of results. We modified Bland and Altman's method, resulting in the smallest detectable differences (SDDs). Two raters measured elbow excursions in 42 individuals (144 ratings per test person) with an electronic digital inclinometer in a classical test-retest crossover study design. The SDDs were 0 +/- 4.2 degrees for active extension; 0 +/- 8.2 degrees for active flexion, both without upper arm fixation; 0 +/- 6.3 degrees for active extension; 0 +/- 5.7 degrees for active flexion; 0 +/- 7.4 degrees for passive flexion with upper arm fixation; 0 +/- 10.1 degrees for active flexion with upper arm retroflexion; and 0 +/- 8.5 degrees and 0 +/- 10.8 degrees for active and passive range of motion. Differences smaller than these SDDs found in clinical or research settings are attributable to measurement error and do not indicate improvement.

  13. Development of Compact Surveillance and Monitoring System 'COSMOS'

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  14. Haemostatic reference intervals in pregnancy

    DEFF Research Database (Denmark)

    Szecsi, Pal Bela; Jørgensen, Maja; Klajnbard, Anna

    2010-01-01

    Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age-specific refe......Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age......-specific reference intervals for coagulation tests during normal pregnancy. Eight hundred one women with expected normal pregnancies were included in the study. Of these women, 391 had no complications during pregnancy, vaginal delivery, or postpartum period. Plasma samples were obtained at gestational weeks 13......-20, 21-28, 29-34, 35-42, at active labor, and on postpartum days 1 and 2. Reference intervals for each gestational period using only the uncomplicated pregnancies were calculated in all 391 women for activated partial thromboplastin time (aPTT), fibrinogen, fibrin D-dimer, antithrombin, free protein S...

  15. The Post-Ovariectomy Interval Affects the Antidepressant-Like Action of Citalopram Combined with Ethynyl-Estradiol in the Forced Swim Test in Middle Aged Rats

    Directory of Open Access Journals (Sweden)

    Nelly M. Vega Rivera

    2016-05-01

    Full Text Available The use of a combined therapy with low doses of estrogens plus antidepressants to treat depression associated to perimenopause could be advantageous. However the use of these combinations is controversial due to several factors, including the time of intervention in relation to menopause onset. This paper analyzes whether time post-OVX influences the antidepressant-like action of a combination of ethynyl-estradiol (EE2 and citalopram (CIT in the forced swim test (FST. Middle-aged (15 months old female Wistar rats were ovariectomized and after one or three weeks treated with EE2 (1.25, 2.5 or 5.0 µg/rat, s.c.; −48 h or CIT (1.25, 2.5, 5.0 or 10 mg/kg, i.p./3 injections in 24 h and tested in the FST. In a second experiment, after one or three weeks of OVX, rats received a combination of an ineffective dose of EE2 (1.25 µg/rat, s.c., −48 h plus CIT (2.5 mg/kg, i.p./3 injections in 24 h and subjected to the FST. Finally, the uteri were removed and weighted to obtain an index of the peripheral effects of EE2 administration. EE2 (2.5 or 5.0 µg/rat reduced immobility after one but not three weeks of OVX. In contrast, no CIT dose reduced immobility at one or three weeks after OVX. When EE2 (1.25 µg/rat was combined with CIT (2.5 mg/kg an antidepressant-like effect was observed at one but not three weeks post-OVX. The weight of the uteri augmented when EE2 was administrated three weeks after OVX. The data suggest that the time post-OVX is a crucial factor that contributes to observe the antidepressant-like effect of EE2 alone or in combination with CIT.

  16. Inter-Pregnancy Interval

    African Journals Online (AJOL)

    Buchi

    This definition excludes. 1, 2 miscarriage as a preceding pregnancy event. Often the IPI is calculated as ... Inter-pregnancy interval of <6 months was significantly associated with an increased risk of adverse subsequent pregnancy outcomes. Mothers 35 years or older at start of childbearing have the highest risk compared to.

  17. Interval methods: An introduction

    DEFF Research Database (Denmark)

    Achenie, L.E.K.; Kreinovich, V.; Madsen, Kaj

    2006-01-01

    This chapter contains selected papers presented at the Minisymposium on Interval Methods of the PARA'04 Workshop '' State-of-the-Art in Scientific Computing ''. The emphasis of the workshop was on high-performance computing (HPC). The ongoing development of ever more advanced computers provides...

  18. Study of FibroTest and hyaluronic acid biological variation in healthy volunteers and comparison of serum hyaluronic acid biological variation between chronic liver diseases of different etiology and fibrotic stage using confidence intervals.

    Science.gov (United States)

    Istaces, Nicolas; Gulbis, Béatrice

    2015-07-01

    Personalized ranges of liver fibrosis serum biomarkers such as FibroTest or hyaluronic acid could be used for early detection of fibrotic changes in patients with progressive chronic liver disease. Our aim was to generate reliable biological variation estimates for these two biomarkers with confidence intervals for within-subject biological variation and reference change value. Nine fasting healthy volunteers and 66 chronic liver disease patients were included. Biological variation estimates were calculated for FibroTest in healthy volunteers, and for hyaluronic acid in healthy volunteers and chronic liver disease patients stratified by etiology and liver fibrosis stage. In healthy volunteers, within-subject biological coefficient of variation (with 95% confidence intervals) and index of individuality were 20% (16%-28%) and 0.6 for FibroTest and 34% (27%-47%) and 0.79 for hyaluronic acid, respectively. Overall hyaluronic acid within-subject biological coefficient of variation was similar among non-alcoholic fatty liver disease and chronic hepatitis C with 41% (34%-52%) and 45% (39%-55%), respectively, in contrast to chronic hepatitis B with 170% (140%-215%). Hyaluronic acid within-subject biological coefficients of variation were similar between F0-F1, F2 and F3 liver fibrosis stages in non-alcoholic fatty liver disease with 34% (25%-49%), 41% (31%-59%) and 34% (23%-62%), respectively, and in chronic hepatitis C with 34% (27%-47%), 33% (26%-45%) and 38% (27%-65%), respectively. However, corresponding hyaluronic acid indexes of individuality were lower in the higher fibrosis stages. Non-overlapping confidence intervals of biological variation estimates allowed us to detect significant differences regarding hyaluronic acid biological variation between chronic liver disease subgroups. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Using Google Trends for influenza surveillance in South China.

    Directory of Open Access Journals (Sweden)

    Min Kang

    Full Text Available BACKGROUND: Google Flu Trends was developed to estimate influenza activity in many countries; however there is currently no Google Flu Trends or other Internet search data used for influenza surveillance in China. METHODS AND FINDINGS: Influenza surveillance data from 2008 through 2011 were obtained from provincial CDC influenza-like illness and virological surveillance systems of Guangdong, a province in south China. Internet search data were downloaded from the website of Google Trends. Pearson's correlation coefficients with 95% confidence intervals (95% CI were calculated to compare surveillance data and internet search trends. The correlation between CDC ILI surveillance and CDC virus surveillance was 0.56 (95% CI: 0.43, 0.66. The strongest correlation was between the Google Trends term of Fever and ILI surveillance with a correlation coefficient of 0.73 (95% CI: 0.66, 0.79. When compared with influenza virological surveillance, the Google Trends term of Influenza A had the strongest correlation with a correlation coefficient of 0.64 (95% CI: 0.43, 0.79 in the 2009 H1N1 influenza pandemic period. CONCLUSIONS: This study shows that Google Trends in Chinese can be used as a complementary source of data for influenza surveillance in south China. More research in the future should develop new models using search trends in Chinese language to estimate local disease activity and detect early signals of outbreaks.

  20. Using Google Trends for influenza surveillance in South China.

    Science.gov (United States)

    Kang, Min; Zhong, Haojie; He, Jianfeng; Rutherford, Shannon; Yang, Fen

    2013-01-01

    Google Flu Trends was developed to estimate influenza activity in many countries; however there is currently no Google Flu Trends or other Internet search data used for influenza surveillance in China. Influenza surveillance data from 2008 through 2011 were obtained from provincial CDC influenza-like illness and virological surveillance systems of Guangdong, a province in south China. Internet search data were downloaded from the website of Google Trends. Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data and internet search trends. The correlation between CDC ILI surveillance and CDC virus surveillance was 0.56 (95% CI: 0.43, 0.66). The strongest correlation was between the Google Trends term of Fever and ILI surveillance with a correlation coefficient of 0.73 (95% CI: 0.66, 0.79). When compared with influenza virological surveillance, the Google Trends term of Influenza A had the strongest correlation with a correlation coefficient of 0.64 (95% CI: 0.43, 0.79) in the 2009 H1N1 influenza pandemic period. This study shows that Google Trends in Chinese can be used as a complementary source of data for influenza surveillance in south China. More research in the future should develop new models using search trends in Chinese language to estimate local disease activity and detect early signals of outbreaks.

  1. Design and Operation of a Borehole Straddle Packer for Ground-Water Sampling and Hydraulic Testing of Discrete Intervals at U.S. Air Force Plant 6, Marietta, Georgia

    Science.gov (United States)

    Holloway, Owen G.; Waddell, Jonathan P.

    2008-01-01

    A borehole straddle packer was developed and tested by the U.S. Geological Survey to characterize the vertical distribution of contaminants, head, and hydraulic properties in open-borehole wells as part of an ongoing investigation of ground-water contamination at U.S. Air Force Plant 6 (AFP6) in Marietta, Georgia. To better understand contaminant fate and transport in a crystalline bedrock setting and to support remedial activities at AFP6, numerous wells have been constructed that include long open-hole intervals in the crystalline bedrock. These wells can include several discontinuities that produce water, which may contain contaminants. Because of the complexity of ground-water flow and contaminant movement in the crystalline bedrock, it is important to characterize the hydraulic and water-quality characteristics of discrete intervals in these wells. The straddle packer facilitates ground-water sampling and hydraulic testing of discrete intervals, and delivery of fluids including tracer suites and remedial agents into these discontinuities. The straddle packer consists of two inflatable packers, a dual-pump system, a pressure-sensing system, and an aqueous injection system. Tests were conducted to assess the accuracy of the pressure-sensing systems, and water samples were collected for analysis of volatile organic compound (VOCs) concentrations. Pressure-transducer readings matched computed water-column height, with a coefficient of determination of greater than 0.99. The straddle packer incorporates both an air-driven piston pump and a variable-frequency, electronic, submersible pump. Only slight differences were observed between VOC concentrations in samples collected using the two different types of sampling pumps during two sampling events in July and August 2005. A test conducted to assess the effect of stagnation on VOC concentrations in water trapped in the system's pump-tubing reel showed that concentrations were not affected. A comparison was conducted

  2. Congenital syphilis surveillance

    Directory of Open Access Journals (Sweden)

    Antonella Marangoni

    2011-06-01

    Full Text Available Congenital syphilis (CS is mainly a consequence of the lack of antenatal care and control of sexually transmitted infections.The bedrock of the prevention of CS is syphilis diagnosis by serological screening during pregnancy.Current Italian guidelines suggest that all the pregnant women should be tested in the first trimester. Due to the frequently absence of specific signs of infection at birth, laboratory tests are often the only method for a correct CS diagnosis. The aim of this study was to evaluate the usefulness of Treponema pallidum IgM Western Blot (WB and Polymerase Chain Reaction (PCR on cerebrospinal fluid (CSF as an aid in the diagnosis of CS during a prospective surveillance study carried out at St. Orsola Hospital in Bologna, Italy, from November 2000 through June 2010. All pregnant women during pregnancy and at delivery were screened for syphilis by ARCHITECT® Syphilis TP, Abbott. Positive samples were further analysed by Treponema Pallidum Hemagglutination Test (TPHA and Rapid Plasma Reagin (RPR tests, Radim.An in-house Western Blot (WB was also performed. Infants born to syphilis seropositive mothers were enrolled in a prospective follow up. At birth, tests were performed (including IgM WB. Infants with positive RPR tests at birth born to mothers not adequately treated received also a long bone radiograph as well as a complete CSF analysis, including Veneral Disease Research Laboratori (VDRL (Siemens Healthcare Diagnostics and PCR testing. All seroreactive infants received careful follow up examinations and serological testing at 0, 3, 6, 9, 12 months or until the tests became negative. In this study, positive syphilis serology was noted in 151 pregnant women delivering in our hospital. Fifteen women had never been adequately treated, and 9 out 15 gave birth to infected newborns.All these 9 infants had positive IgM WB results on serum samples. Two babies had characteristic long bone lesions at X-ray examination and 3 were born

  3. Nonparametric confidence intervals for monotone functions

    NARCIS (Netherlands)

    Groeneboom, P.; Jongbloed, G.

    2015-01-01

    We study nonparametric isotonic confidence intervals for monotone functions. In [Ann. Statist. 29 (2001) 1699–1731], pointwise confidence intervals, based on likelihood ratio tests using the restricted and unrestricted MLE in the current status model, are introduced. We extend the method to the

  4. Contrast-enhanced US with Perfluorobutane(Sonazoid) used as a surveillance test for Hepatocellular Carcinoma (HCC) in Cirrhosis (SCAN): an exploratory cross-sectional study for a diagnostic trial.

    Science.gov (United States)

    Park, Ji Hoon; Park, Mi-Suk; Lee, So Jung; Jeong, Woo Kyoung; Lee, Jae Young; Park, Min Jung; Han, Kyunghwa; Nam, Chung Mo; Park, Seong Ho; Lee, Kyoung Ho

    2017-04-18

    Ultrasonography (US) is widely used as a standard surveillance tool for patients who are at a high risk of having hepatocellular carcinoma (HCC); however, conventional B-mode US appears to be insufficient in order to ensure the early detection of HCC. Perfluorobutane allows very stable Kupffer phase imaging for at least 60 min, which is tolerable for examinations of the entire liver. The purpose of our study is to evaluate the added value of contrast-enhanced US using perfluorobutane to that of conventional B-mode US as an HCC surveillance tool for patients with liver cirrhosis. SCAN (Sonazoid-US for surveillance of hepatoCellulArcarciNoma) is a prospective, multi-institutional, diagnostic trial using an intra-individual comparison design in a single arm of patients. This study was approved by our five institutional review board and informed consent was obtained from all participating. We obtained consent for publication of these data (contrast enhanced US images, CT or MRI images, laboratory findings, age, sex) from all participating patients. All patients will undergo conventional B-mode US immediately followed by contrast-enhanced US. The standardized case report forms will be completed by operating radiologists after B-mode US and contrast-enhanced US, respectively. If any lesion(s) is detected, the likelihood of HCC will be recorded. The primary endpoints are a detection rate of early-stage HCC and a false referral rate of HCC. Intra-individual comparison using Mcnemar's test will be performed between B-mode US and contrast-enhanced US. The study will include 523 patients under HCC surveillance in five medical institutions in Korea. SCAN is the first study to investigate the efficacy of contrast-enhanced US in surveillance using two reciprocal endpoints specialized for the evaluation of a surveillance test. SCAN will provide evidence regarding whether patients can truly benefit from contrast-enhanced US in terms of the detection of early stage HCC while

  5. The development and pilot testing of the marijuana retail surveillance tool (MRST): assessing marketing and point-of-sale practices among recreational marijuana retailers.

    Science.gov (United States)

    Berg, Carla J; Henriksen, Lisa; Cavazos-Rehg, Patricia; Schauer, Gillian L; Freisthler, Bridget

    2017-12-01

    As recreational marijuana expands, it is critical to develop standardized surveillance measures to study the retail environment. To this end, our research team developed and piloted a tool assessing recreational marijuana retailers in a convenience sample of 20 Denver retailers in 2016. The tool assesses: (i) compliance and security (e.g. age-of-sale signage, ID checks, security cameras); (ii) marketing (i.e. promotions, product availability and price) and (iii) contextual and neighborhood features (i.e. retailer type, facilities nearby). Most shops (90.0%) indicated the minimum age requirement, all verified age. All shops posted interior ads (M = 2.6/retailer, SD = 3.4), primarily to promote edibles and other non-smoked products. Price promotions were common in shops (73.7%), 57.9% used social media promotions and 31.6% had take-away materials (e.g. menus, party promotions). Nearly half of the shops (42.1%) advertised health claims. All shops offered bud, joints, honey oil, tinctures, kief, beverages, edibles and topicals; fewer sold clones and seeds. Six shops (31.6%) sold shop-branded apparel and/or paraphernalia. Prices for bud varied within and between stores ($20-$45/'eighth', ∼3.5 g). Twelve were recreational only, and eight were both recreational and medicinal. Liquor stores were commonly proximal. Reliability assessments with larger, representative samples are needed to create a standardized marijuana retail surveillance tool. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Haemostatic reference intervals in pregnancy.

    Science.gov (United States)

    Szecsi, Pal B; Jørgensen, Maja; Klajnbard, Anna; Andersen, Malene R; Colov, Nina P; Stender, Steen

    2010-04-01

    Haemostatic reference intervals are generally based on samples from non-pregnant women. Thus, they may not be relevant to pregnant women, a problem that may hinder accurate diagnosis and treatment of haemostatic disorders during pregnancy. In this study, we establish gestational age-specific reference intervals for coagulation tests during normal pregnancy. Eight hundred one women with expected normal pregnancies were included in the study. Of these women, 391 had no complications during pregnancy, vaginal delivery, or postpartum period. Plasma samples were obtained at gestational weeks 13-20, 21-28, 29-34, 35-42, at active labor, and on postpartum days 1 and 2. Reference intervals for each gestational period using only the uncomplicated pregnancies were calculated in all 391 women for activated partial thromboplastin time (aPTT), fibrinogen, fibrin D-dimer, antithrombin, free protein S, and protein C and in a subgroup of 186 women in addition for prothrombin time (PT), Owren and Quick PT, protein S activity, and total protein S and coagulation factors II, V, VII, VIII, IX, X, XI, and XII. The level of coagulation factors II, V, X, XI, XII and antithrombin, protein C, aPTT, PT remained largely unchanged during pregnancy, delivery, and postpartum and were within non-pregnant reference intervals. However, levels of fibrinogen, D-dimer, and coagulation factors VII, VIII, and IX increased markedly. Protein S activity decreased substantially, while free protein S decreased slightly and total protein S was stable. Gestational age-specific reference values are essential for the accurate interpretation of a subset of haemostatic tests during pregnancy, delivery, and puerperium.

  7. Applications of interval computations

    CERN Document Server

    Kreinovich, Vladik

    1996-01-01

    Primary Audience for the Book • Specialists in numerical computations who are interested in algorithms with automatic result verification. • Engineers, scientists, and practitioners who desire results with automatic verification and who would therefore benefit from the experience of suc­ cessful applications. • Students in applied mathematics and computer science who want to learn these methods. Goal Of the Book This book contains surveys of applications of interval computations, i. e. , appli­ cations of numerical methods with automatic result verification, that were pre­ sented at an international workshop on the subject in EI Paso, Texas, February 23-25, 1995. The purpose of this book is to disseminate detailed and surveyed information about existing and potential applications of this new growing field. Brief Description of the Papers At the most fundamental level, interval arithmetic operations work with sets: The result of a single arithmetic operation is the set of all possible results as the o...

  8. Autonomous surveillance for biosecurity.

    Science.gov (United States)

    Jurdak, Raja; Elfes, Alberto; Kusy, Branislav; Tews, Ashley; Hu, Wen; Hernandez, Emili; Kottege, Navinda; Sikka, Pavan

    2015-04-01

    The global movement of people and goods has increased the risk of biosecurity threats and their potential to incur large economic, social, and environmental costs. Conventional manual biosecurity surveillance methods are limited by their scalability in space and time. This article focuses on autonomous surveillance systems, comprising sensor networks, robots, and intelligent algorithms, and their applicability to biosecurity threats. We discuss the spatial and temporal attributes of autonomous surveillance technologies and map them to three broad categories of biosecurity threat: (i) vector-borne diseases; (ii) plant pests; and (iii) aquatic pests. Our discussion reveals a broad range of opportunities to serve biosecurity needs through autonomous surveillance. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. 522 Postmarket Surveillance Studies

    Data.gov (United States)

    U.S. Department of Health & Human Services — The 522 Postmarket Surveillance Studies Program encompasses design, tracking, oversight, and review responsibilities for studies mandated under section 522 of the...

  10. Assessment of an outreach street-based HIV rapid testing programme as a strategy to promote early diagnosis: a comparison with two surveillance systems in Spain, 2008-2011.

    Science.gov (United States)

    Belza, M J; Hoyos, J; Fernández-Balbuena, S; Diaz, A; Bravo, M J; de la Fuente, L

    2015-04-09

    We assess the added value of a multisite, street-based HIV rapid testing programme by comparing its results to pre-existing services and assessing its potential to reduce ongoing transmission. Between 2008 and 2011, 8,923 individuals underwent testing. We compare outcomes with those of a network of 20 sexually transmitted infections (STI)/HIV clinics (EPI-VIH) and the Spanish National HIV Surveillance System (SNHSS); evaluate whether good visibility prompts testing and assess whether it reaches under-tested populations. 89.2% of the new infections were in men who have sex with men (MSM) vs 78.0% in EPI-VIH and 56.0% in SNHSS. 83.6% of the MSM were linked to care and 20.9% had VIH. 56.5% of the HIV-positive MSM tested because they happened to see the programme, 18.4% were previously untested and 26.3% had their last test ≥2 years ago. The programme provided linkage to care and early diagnosis mainly to MSM but attendees presented a lower HIV prevalence than EPI-VIH. From a cost perspective it would benefit from being implemented in locations highly frequented by MSM. Conversely, its good visibility led to reduced periods of undiagnosed infection in a high proportion of MSM who were not testing with the recommended frequency.

  11. Mobile Surveillance and Monitoring Robots

    Energy Technology Data Exchange (ETDEWEB)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-07-14

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment.

  12. Mobile Surveillance and Monitoring Robots

    International Nuclear Information System (INIS)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-01-01

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment

  13. Interval orders and reverse mathematics

    OpenAIRE

    Marcone, Alberto

    2006-01-01

    We study the reverse mathematics of interval orders. We establish the logical strength of the implications between various definitions of the notion of interval order. We also consider the strength of different versions of the characterization theorem for interval orders: a partial order is an interval order if and only if it does not contain $2 \\oplus 2$. We also study proper interval orders and their characterization theorem: a partial order is a proper interval order if and only if it cont...

  14. Marginal Expense Oil Well Wireless Surveillance (MEOWWS)

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Donald G.

    2002-03-11

    The objective of this study was to identify and field test a new, low cost, wireless oil well surveillance system. A variety of suppliers and technologies were considered. One supplier and system was chosen that was low cost, new to the oil field, and successfully field tested.

  15. Atucha I nuclear power plant surveillance programme

    International Nuclear Information System (INIS)

    Jinchuk, D.

    1993-01-01

    After a review of the main characteristics of the Atucha I nuclear power plant and its pressure vessel, the embrittlement surveillance capsules and the irradiation conditions are described; Charpy impact tests and tensile tests were performed on the irradiated samples, and results are discussed and compared to theoretical calculations: transition temperature shifts, displacement per atom values. 6 refs., 16 figs., 7 tabs

  16. Radiation surveillance using an unmanned aerial vehicle.

    Science.gov (United States)

    Pöllänen, Roy; Toivonen, Harri; Peräjärvi, Kari; Karhunen, Tero; Ilander, Tarja; Lehtinen, Jukka; Rintala, Kimmo; Katajainen, Tuure; Niemelä, Jarkko; Juusela, Marko

    2009-02-01

    Radiation surveillance equipment was mounted in a small unmanned aerial vehicle. The equipment consists of a commercial CsI detector for count rate measurement and a specially designed sampling unit for airborne radioactive particles. Field and flight tests were performed for the CsI detector in the area where (137)Cs fallout from the Chernobyl accident is 23-45 kBq m(-2). A 3-GBq (137)Cs point source could be detected at the altitude of 50 m using a flight speed of 70 km h(-1) and data acquisition interval of 1s. Respective response for (192)Ir point source is 1 GBq. During the flight, the detector reacts fast to ambient external dose rate rise of 0.1 microSv h(-1), which gives for the activity concentration of (131)I less than 1 kB qm(-3). Operation of the sampler equipped with different type of filters was investigated using wind-tunnel experiments and field tests with the aid of radon progeny. Air flow rate through the sampler is 0.2-0.7 m(3)h(-1) at a flight speed of 70 km h(-1) depending on the filter type in question. The tests showed that the sampler is able to collect airborne radioactive particles. Minimum detectable concentration for transuranium nuclides, such as (239)Pu, is of the order of 0.2 Bq m(-3) or less when alpha spectrometry with no radiochemical sample processing is used for activity determination immediately after the flight. When a gamma-ray spectrometer is used, minimum detectable concentrations for several fission products such as (137)Cs and (131)I are of the order of 1 Bq m(-3).

  17. Reviewing surveillance activities in nuclear power plants

    International Nuclear Information System (INIS)

    1989-03-01

    This document provides guidance to Operational Safety Review Teams (OSARTs) for reviewing surveillance activities at a nuclear power plant. In addition, the document contains reference material to support the review of surveillance activities, to assist within the Technical Support area and to ensure consistency between individual reviews. Drafts of the document have already been used on several OSART missions and found to be useful. The document first considers the objectives of an excellent surveillance programme. Investigations to determine the quality of the surveillance programme are then discussed. The attributes of an excellent surveillance programme are listed. Advice follows on how to phrase questions so as to obtain an informative response on surveillance features. Finally, specific equipment is mentioned that should be considered when reviewing functional tests. Four annexes provide examples drawn from operating nuclear power plants. They were selected to supplement the main text of the document with the best international practices as found in OSART reviews. They should in no way limit the acceptance and development of alternative approaches that lead to equivalent or better results. Refs, figs and tabs

  18. Chaos on the interval

    CERN Document Server

    Ruette, Sylvie

    2017-01-01

    The aim of this book is to survey the relations between the various kinds of chaos and related notions for continuous interval maps from a topological point of view. The papers on this topic are numerous and widely scattered in the literature; some of them are little known, difficult to find, or originally published in Russian, Ukrainian, or Chinese. Dynamical systems given by the iteration of a continuous map on an interval have been broadly studied because they are simple but nevertheless exhibit complex behaviors. They also allow numerical simulations, which enabled the discovery of some chaotic phenomena. Moreover, the "most interesting" part of some higher-dimensional systems can be of lower dimension, which allows, in some cases, boiling it down to systems in dimension one. Some of the more recent developments such as distributional chaos, the relation between entropy and Li-Yorke chaos, sequence entropy, and maps with infinitely many branches are presented in book form for the first time. The author gi...

  19. Veterinary surveillance laboratories: developing the training program.

    Science.gov (United States)

    Mitchell, Staci L; McCline, Katasha T; Hanfelt, Margery M

    2010-01-01

    The increased need and demand for onsite, frequent, rapid, and portable food and bottled water testing for indicators of microbiological and chemical agents led to the deployment of 2 laboratory veterinary equipment sets. A Surveillance Food Laboratory Program (SFLP) was developed to allow Veterinary Corps commanders to establish targeted testing programs to enhance food safety and wholesomeness, along with faster responses to food defense, suspected foodborne illness, and food/water risk assessment missions. To support the deployment of the veterinary equipment sets and the SFLP, 2 new functional courses were developed by the Department of Veterinary Science. The Surveillance Food Laboratory Technician Course teaches essential technical skills that include sample processing, assay methodologies, results review, and interpretation of results produced by these laboratories. The Surveillance Food Laboratory Manager Course, developed for designated managers of the laboratories and laboratory programs, teaches the skills critical to ensuring proper surveillance laboratory oversight, testing, evaluation of results, risk communication, and response to presumptive positive results produced by the laboratories. Together, the courses allowed for the successful deployment of the unique veterinary equipment sets, resulting in development of fully operational surveillance laboratories in support of food protection missions in every major theater of operations.

  20. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  1. Interval Female Sterilization.

    Science.gov (United States)

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  2. Multichannel interval timer

    International Nuclear Information System (INIS)

    Turko, B.T.

    1983-10-01

    A CAMAC based modular multichannel interval timer is described. The timer comprises twelve high resolution time digitizers with a common start enabling twelve independent stop inputs. Ten time ranges from 2.5 μs to 1.3 μs can be preset. Time can be read out in twelve 24-bit words either via CAMAC Crate Controller or an external FIFO register. LSB time calibration is 78.125 ps. An additional word reads out the operational status of twelve stop channels. The system consists of two modules. The analog module contains a reference clock and 13 analog time stretchers. The digital module contains counters, logic and interface circuits. The timer has an excellent differential linearity, thermal stability and crosstalk free performance

  3. Interpretando correctamente en salud pública estimaciones puntuales, intervalos de confianza y contrastes de hipótesis Accurate interpretation of point estimates, confidence intervals, and hypothesis tests in public health

    Directory of Open Access Journals (Sweden)

    Manuel G Scotto

    2003-12-01

    Full Text Available El presente ensayo trata de aclarar algunos conceptos utilizados habitualmente en el campo de investigación de la salud pública, que en numerosas situaciones son interpretados de manera incorrecta. Entre ellos encontramos la estimación puntual, los intervalos de confianza, y los contrastes de hipótesis. Estableciendo un paralelismo entre estos tres conceptos, podemos observar cuáles son sus diferencias más importantes a la hora de ser interpretados, tanto desde el punto de vista del enfoque clásico como desde la óptica bayesiana.This essay reviews some statistical concepts frequently used in public health research that are commonly misinterpreted. These include point estimates, confidence intervals, and hypothesis tests. By comparing them using the classical and the Bayesian perspectives, their interpretation becomes clearer.

  4. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  5. Surveillance extension experience at WWER-440 type reactors

    International Nuclear Information System (INIS)

    Gillemot, F.; Uri, G.; Oszwald, F.; Trampus, P.

    1993-01-01

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs

  6. Advances in surveillance of periodontitis: the Centers for Disease Control and Prevention periodontal disease surveillance project.

    Science.gov (United States)

    Eke, Paul I; Thornton-Evans, Gina; Dye, Bruce; Genco, Robert

    2012-11-01

    The Centers for Disease Control and Prevention (CDC) has as one of its strategic goals to support and improve surveillance of periodontal disease. In 2003, the CDC initiated the CDC Periodontal Disease Surveillance Project in collaboration with the American Academy of Periodontology to address population-based surveillance of periodontal disease at the local, state, and national levels. This initiative has made significant advancements toward the goal of improved surveillance, including developing valid self-reported measures that can be obtained from interview-based surveys to predict prevalence of periodontitis in populations. This will allow surveillance of periodontitis at the state and local levels and in countries where clinical resources for surveillance are scarce. This work has produced standard case definitions for surveillance of periodontitis that are now widely recognized and applied in population studies and research. At the national level, this initiative has evaluated the validity of previous clinical examination protocols and tested new protocols on the National Health and Nutrition Examination Survey (NHANES), recommending and supporting funding for the gold-standard full-mouth periodontal examination in NHANES 2009 to 2012. These examinations will generate accurate estimates of the prevalence of periodontitis in the US adult population and provide a superior dataset for surveillance and research. Also, this data will be used to generate the necessary coefficients for our self-report questions for use in subsets of the total US population. The impact of these findings on population-based surveillance of periodontitis and future directions of the project are discussed along with plans for dissemination and translation efforts for broader public health use.

  7. Interval by interval analysis of commercial drilling speed

    Energy Technology Data Exchange (ETDEWEB)

    Dublenich, L.B.; Gor' kov, A.P.

    1984-01-01

    The results are cited of an interval by interval analysis of the commercial drilling speeds in individual sites of the Carpathian region (Skhodnitsa, Dolina, Duvboshanka) which attest to the presence of reserves for increasing the commercial drilling speeds.

  8. Incidentally detected lung nodules: clinical predictors of adherence to Fleischner Society surveillance guidelines.

    Science.gov (United States)

    Ridge, Carole A; Hobbs, Brian D; Bukoye, Bolanle A; Aronson, Mark D; Boiselle, Phillip M; Leffler, Daniel A; Sternberg, Scot B; Roberts, David H

    2014-01-01

    The objective of this study was to determine adherence to incidentally detected lung nodule computed tomographic (CT) surveillance recommendations and identify demographic and clinical factors that increase the likelihood of CT surveillance. A total of 419 patients with incidentally detected lung nodules were included. Recorded data included patient demographic, radiologic, and clinical characteristics and outcomes at a 4-year follow-up. Multivariate logistic regression models determined the factors associated with likelihood of recommended CT surveillance. At least 1 recommended surveillance chest CT was performed on 48% of the patients (148/310). Computed tomographic result communication to the patient (odds ratio [OR], 2.2; P = 0.006; confidence interval [CI], 1.3-4.0) or to the referring physician (OR, 2.8; P = 0.001; CI, 1.7-4.5) and recommendation of a specific surveillance time interval (OR, 1.7; P = 0.023; CI, 1.08-2.72) increased the likelihood of surveillance. Other demographic, radiologic, and clinical factors did not influence surveillance. Documented physician and patient result communication as well as the recommendation of a specific surveillance time interval increased the likelihood of CT surveillance of incidentally detected lung nodules.

  9. Workers' health surveillance: implementation of the Directive 89/391/EEC in Europe

    NARCIS (Netherlands)

    Colosio, C.; Mandic-Rajcevic, S.; Godderis, L.; van der Laan, G.; Hulshof, C.; van Dijk, F.

    2017-01-01

    Background European Union (EU) Directive 89/391 addressed occupational health surveillance, which recommends to provide workers with `access to health surveillance at regular intervals', aiming to prevent work-related and occupational diseases. Aims To investigate how EU countries adopted this

  10. Adherence to surveillance guidelines after removal of colorectal adenomas: a large, community-based study

    NARCIS (Netherlands)

    van Heijningen, Else-Mariëtte B.; Lansdorp-Vogelaar, Iris; Steyerberg, Ewout W.; Goede, S. Lucas; Dekker, Evelien; Lesterhuis, Wilco; ter Borg, Frank; Vecht, Juda; Spoelstra, Pieter; Engels, Leopold; Bolwerk, Clemens J. M.; Timmer, Robin; Kleibeuker, Jan H.; Koornstra, Jan J.; de Koning, Harry J.; Kuipers, Ernst J.; van Ballegooijen, Marjolein

    2015-01-01

    To determine adherence to recommended surveillance intervals in clinical practice. 2997 successive patients with a first adenoma diagnosis (57% male, mean age 59 years) from 10 hospitals, who underwent colonoscopy between 1998 and 2002, were identified via Pathologisch Anatomisch Landelijk

  11. The plays and arts of surveillance: studying surveillance as entertainment

    NARCIS (Netherlands)

    Albrechtslund, Anders; Dubbeld, L.

    2006-01-01

    This paper suggests a direction in the development of Surveillance Studies that goes beyond current attention for the caring, productive and enabling aspects of surveillance practices. That is, surveillance could be considered not just as positively protective, but even as a comical, playful,

  12. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    NARCIS (Netherlands)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos; Fernandez-Vozmediano, José M; Ayala, Fabio; Balato, Anna; Bauer, Andrea; Ballmer-Weber, Barbara; Beliauskiene, Aiste; Fortina, Anna Belloni; Bircher, Andreas; Brasch, Jochen; Chowdhury, Mahbub M U; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise; Cooper, Sue; Czarnecka-Operacz, Magda; Zmudzinska, Maria; Elsner, Peter; English, John S C; Frosch, Peter J; Fuchs, Thomas; García-Gavín, Juan; Fernández-Redondo, Virginia; Gawkrodger, David J; Giménez-Arnau, Ana; Green, Cathy M; Horne, Helen L; Johansen, Jeanne Duus; Jolanki, Riitta; Pesonen, Maria; King, Clodagh M; Krêcisz, Beata; Chomiczewska, Dorota; Kiec-Swierczynska, Marta; Larese, Francesca; Mahler, Vera; Ormerod, Anthony D; Peserico, Andrea; Rantanen, Tapio; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Sansom, Jane E; Silvestre, Juan Fco; Simon, Dagmar; Spiewak, Radoslaw; Statham, Barry N; Stone, Natalie; Wilkinson, Mark; Schnuch, Axel

    BACKGROUND: The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in

  13. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos

    2012-01-01

    The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutive...

  14. 2012 Sexually Transmitted Diseases Surveillance

    Science.gov (United States)

    ... Submit Search The CDC 2012 Sexually Transmitted Diseases Surveillance Note: Javascript is disabled or is not supported ... page: About CDC.gov . 2012 Sexually Transmitted Diseases Surveillance Table of Contents Introductory Section Foreword Preface Acronyms ...

  15. Conic surveillance evasion

    NARCIS (Netherlands)

    Lewin, J.; Olsder, G.J.

    1979-01-01

    A surveillance-evasion differential game of degree with a detection zone in the shape of a two-dimensional cone is posed. The nature of the optimal strategies and the singular phenomena of the value function are described and correlated to subsets of the space of all possible parameter combinations,

  16. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.; Hammer, J.

    1988-01-01

    The development progress during the reporting period 1988 of the laser surveillance system of spent fuel pools is summarized. The present engineered system comes close to a final version for field application as all technical questions have been solved in 1988. 14 figs., 1 tab. (Author)

  17. Active surveillance for localized prostate cancer

    DEFF Research Database (Denmark)

    Thomsen, Frederik B; Berg, Kasper D; Røder, M Andreas

    2015-01-01

    OBJECTIVE: Evidence supports active surveillance (AS) as a means to reduce overtreatment of low-risk prostate cancer (PCa). The consequences of close and long-standing follow-up with regard to outpatient visits, tests and repeated biopsies are widely unknown. This study investigated the trajectory...

  18. Product interval automata

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    Page 1 .... experimental front to test the practical applicability of the models and techniques presented here. From a theoretical standpoint, PI automata are strictly less expressive than event clock ... It turns out that all our ideas can be extended smoothly to a larger setting in which the underlying “symbolic” automata are ...

  19. Extended surveillance as a support to PLIM

    International Nuclear Information System (INIS)

    Walle, Eric van

    2002-01-01

    Full text: The safe exploitation of the reactor pressure vessel was and is always a major concern in nuclear power plant life management. At present, issues like Plant Life Extension, where utilities look into the possibility of license renewal after 40 years of operation, are becoming relevant in the USA. In other countries PLIM beyond the design life of the NPP could also be desirable from the economic viewpoint. The limiting factor could, however, be the integrity of the reactor pressure vessel. The reactor pressure vessel surveillance procedures as defined by regulatory legislation is limited and can be supplemented with valuable information that can be extracted in parallel to conventional surveillance testing or through additional testing on surveillance material. This is justified for several reasons: 1. The current methodology is semi-empirical, contains flaws and is in a number of cases over conservative. Without giving in on safety, we need to try and understand the material behavior more fundamentally; 2. Some reactor surveillance materials demonstrate inconsistent behavior with respect to the overall trend. These materials are called 'outlier' materials. But are they really outliers or is this connected to the indexing methodology used? 3. Additional data, for example the results of instrumented Charpy-V impact tests, have been obtained on many surveillance test specimens and are not adequately exploited in the actual surveillance methodology; 4. Scientific research provides substantial information and understanding of degradation mechanisms in reactor pressure vessel steels. Although we will not concentrate on this topic, the development of powerful microscopic investigation techniques, like FEGSTEM, APFIM, SANS, positron annihilation, internal friction, ... led to an intensified development of radiation damage modelling and are an input to micromechanical modelling. Moreover, due to the ever increasing computer power, additional multi-scale (time and

  20. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1996-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the US Department of Energy (DOE). This document contains the planned 1996 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project

  1. A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Junfeng; Newell, John D. [Departments of Radiology and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242 (United States); Wang, Chao; Chan, Kung-Sik [Department of Statistics and Actuarial Science, University of Iowa, Iowa City, Iowa 52242 (United States); Jin, Dakai; Saha, Punam K. [Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa 52242 (United States); Sieren, Jered P. [Department of Radiology, University of Iowa, Iowa City, Iowa 52242 (United States); Barr, R. G. [Departments of Medicine and Epidemiology, Columbia University Medical Center, New York, New York 10032 (United States); Han, MeiLan K. [Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan 48109 (United States); Kazerooni, Ella [Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Cooper, Christopher B. [Department of Medicine, University of California, Los Angeles, California 90095 (United States); Couper, David [Department of Biostatistics, University of North Carolina, Chapel Hill, North Carolina 27599 (United States); Hoffman, Eric A., E-mail: eric-hoffman@uiowa.edu [Departments of Radiology, Medicine and Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242 (United States)

    2016-05-15

    Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS

  2. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools (SFSP's) will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a full size laser system operating in air and have used an array of 6 zircaloy BWR tubes to simulate an assembly. The reflective signal from the zircaloy rods is a strong function of position of the assembly, but in all cases is easily discernable from the reference scan of the background with no assembly. A design for a SFSP laser surveillance system incorporating laser ranging is discussed. 10 figures

  3. MARGINAL EXPENSE OIL WELL WIRELESS SURVEILLANCE MEOWS

    Energy Technology Data Exchange (ETDEWEB)

    Mason M. Medizade; John R. Ridgely; Donald G. Nelson

    2004-11-01

    A marginal expense oil well wireless surveillance system to monitor system performance and production from rod-pumped wells in real time from wells operated by Vaquero Energy in the Edison Field, Main Area of Kern County in California has been successfully designed and field tested. The surveillance system includes a proprietary flow sensor, a programmable transmitting unit, a base receiver and receiving antenna, and a base station computer equipped with software to interpret the data. First, the system design is presented. Second, field data obtained from three wells is shown. Results of the study show that an effective, cost competitive, real-time wireless surveillance system can be introduced to oil fields across the United States and the world.

  4. Routine airway surveillance in pediatric tracheostomy patients.

    Science.gov (United States)

    Gergin, Ozgul; Adil, Eelam; Kawai, Kosuke; Watters, Karen; Moritz, Ethan; Rahbar, Reza

    2017-06-01

    The aim of this study is to review airway findings in children with tracheostomies who underwent surveillance direct laryngoscopy and bronchoscopy (DLB) to determine the yield of routine airway evaluation in these patients. Retrospective chart review at tertiary referral children's hospital. A retrospective chart review was conducted of all of the children with tracheostomies who underwent DLB after tracheostomy between 1984 and 2015. A total of 303 patients met inclusion criteria. The median time interval between tracheostomy and first follow-up DLB was 12.0 months (IQR 4.8-28.9 months). There was no significant difference in the incidence of airway lesions between patients who underwent endoscopy tracheostomy versus those who had a longer time interval between tracheostomy and DLB (p = 0.16). One hundred sixty seven patients (55.1%) were diagnosed with lesions, with suprastomal granulation (39.9%) being the most common. Symptomatic patients were significantly more likely to have an airway lesion identified (69.9% versus 42.0%; p tracheostomy were significantly more likely to have an airway lesion (p = 0.01). The high incidence of airway lesions noted during surveillance DLB support the utility of routine airway endoscopy in pediatric tracheostomy patients. Symptomatic patients, those with ventilator dependence, or cardiopulmonary or trauma indications for tracheostomy are more likely to have airway lesions and should be monitored closely. The ideal time interval between surveillance endoscopies needs to be examined further. Copyright © 2017. Published by Elsevier B.V.

  5. Establishing reference intervals in the coagulation laboratory.

    Science.gov (United States)

    Castellone, D D

    2017-05-01

    Obtaining a reference interval (RI) is a challenge for any laboratory and becomes more complicated in the coagulation laboratory due to testing on samples with limited stability on reagents that are poorly standardized. Reference intervals are required to be able to evaluate results in relation to a patients' hemostatic disorder. This becomes one of the most important tasks conducted in the coagulation laboratory. However, many laboratories lack the time, finances and in many cases the expertise to conduct this study. Many RI are obtained from package inserts, or from publications written by experts in lieu of laboratories conducting their own studies. An overview of validating reference intervals and options for verifying or transference of reference intervals is discussed. Based on the confidence interval and the acceptability of risk laboratories are willing to accept, coagulation laboratories have options to conduct robust studies for their RI. Data mining or global reference studies may help to provide data for age specific ranges. Pre-analytical variables and selection of healthy subjects have the largest impact on coagulation testing outcomes and need to be well controlled during the establishment of reference intervals. Laboratories have options in lieu of conducting a full validation on how to verify RI based on smaller RI studies or transference of RI after determining compatibility of the original RI study. © 2017 John Wiley & Sons Ltd.

  6. Assessment of the Activity of Tigecycline against Gram-Positive and Gram-Negative Organisms Collected from Italy between 2012 and 2014, as Part of the Tigecycline Evaluation and Surveillance Trial (T.E.S.T.

    Directory of Open Access Journals (Sweden)

    Stefania Stefani

    2016-11-01

    Full Text Available As part of the Tigecycline Evaluation and Surveillance Trial (T.E.S.T we report the in vitro activity of tigecycline and its comparators against Gram-negative and Gram-positive organisms collected from Italian centers between 2012 and 2014. Minimum inhibitory concentrations were determined according to the broth microdilution methodology of the Clinical and Laboratory Standards Institute, and antimicrobial resistance was determined using the European Committee on Antimicrobial Susceptibility Testing interpretive criteria. Among the Enterobacteriaceae, 31% of Escherichia coli isolates, 22% of Klebsiella pneumoniae, and 1% of Klebsiella oxytoca were extended-spectrum β-lactamase producers (ESBLs. Resistance rates among ESBL-K. pneumoniae and ESBL-E. coli to meropenem were 24% and <1%, respectively. Thirty-seven percent of K. pneumoniae were multidrug resistant (MDR strains. Resistance rates among isolates of Acinetobacter baumannii to amikacin, levofloxacin and meropenem were between 84% and 94%. Eighty percent of A. baumannii isolates were MDR strains. Methicillin-resistant Staphylococcus aureus (MRSA accounted for 38% of S. aureus isolates. No isolates of MRSA were resistant to linezolid, tigecycline or vancomycin. Antimicrobial resistance remains a problem in Italy with increasing numbers of MDR organisms. Despite high levels, MRSA rates appear to be stabilising. Tigecycline retains its in vitro activity against the majority of organisms, including those with multidrug resistance.

  7. Video surveillance using distance maps

    Science.gov (United States)

    Schouten, Theo E.; Kuppens, Harco C.; van den Broek, Egon L.

    2006-02-01

    Human vigilance is limited; hence, automatic motion and distance detection is one of the central issues in video surveillance. Hereby, many aspects are of importance, this paper specially addresses: efficiency, achieving real-time performance, accuracy, and robustness against various noise factors. To obtain fully controlled test environments, an artificial development center for robot navigation is introduced in which several parameters can be set (e.g., number of objects, trajectories and type and amount of noise). In the videos, for each following frame, movement of stationary objects is detected and pixels of moving objects are located from which moving objects are identified in a robust way. An Exact Euclidean Distance Map (E2DM) is utilized to determine accurately the distances between moving and stationary objects. Together with the determined distances between moving objects and the detected movement of stationary objects, this provides the input for detecting unwanted situations in the scene. Further, each intelligent object (e.g., a robot), is provided with its E2DM, allowing the object to plan its course of action. Timing results are specified for each program block of the processing chain for 20 different setups. So, the current paper presents extensive, experimentally controlled research on real-time, accurate, and robust motion detection for video surveillance, using E2DMs, which makes it a unique approach.

  8. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, A.; Bodal, T.; Sunde, S.

    1998-01-01

    The Institutt for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators, which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including VVERs. The main differences between VVERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a VVER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(author)

  9. Fast transfer of crossmodal time interval training.

    Science.gov (United States)

    Chen, Lihan; Zhou, Xiaolin

    2014-06-01

    Sub-second time perception is essential for many important sensory and perceptual tasks including speech perception, motion perception, motor coordination, and crossmodal interaction. This study investigates to what extent the ability to discriminate sub-second time intervals acquired in one sensory modality can be transferred to another modality. To this end, we used perceptual classification of visual Ternus display (Ternus in Psychol Forsch 7:81-136, 1926) to implicitly measure participants' interval perception in pre- and posttests and implemented an intra- or crossmodal sub-second interval discrimination training protocol in between the tests. The Ternus display elicited either an "element motion" or a "group motion" percept, depending on the inter-stimulus interval between the two visual frames. The training protocol required participants to explicitly compare the interval length between a pair of visual, auditory, or tactile stimuli with a standard interval or to implicitly perceive the length of visual, auditory, or tactile intervals by completing a non-temporal task (discrimination of auditory pitch or tactile intensity). Results showed that after fast explicit training of interval discrimination (about 15 min), participants improved their ability to categorize the visual apparent motion in Ternus displays, although the training benefits were mild for visual timing training. However, the benefits were absent for implicit interval training protocols. This finding suggests that the timing ability in one modality can be rapidly acquired and used to improve timing-related performance in another modality and that there may exist a central clock for sub-second temporal processing, although modality-specific perceptual properties may constrain the functioning of this clock.

  10. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  11. Disaster prevention surveillance system

    International Nuclear Information System (INIS)

    Nara, Satoru; Kamiya, Eisei

    2001-01-01

    Fuji Electric Co., Ltd. has supplied many management systems to nuclear reactor institution. 'The nuclear countermeasures-against-calamities special-measures' was enforced. A nuclear entrepreneur has devised the measure about expansion prevention and restoration of a calamity while it endeavors after prevention of generating of a nuclear calamity. Our company have supplied the 'disaster prevention surveillance system' to the Japan Atomic Energy Research Institute Tokai Research Establishment aiming at strengthening of the monitoring function at the time (after the accident) of the accident used as one of the above-mentioned measures. A 'disaster prevention surveillance system' can share the information on the accident spot in an on-site command place, an activity headquarters, and support organizations, when the serious accident happens. This system is composed of various sensors (temperature, pressure and radiation), cameras, computers and network. (author)

  12. Medical Surveillance Monthly Report

    Science.gov (United States)

    2016-10-01

    members seeking care for the condition or resulted in increased screening for the condition , which would subsequently increase the number of cases...R E S P A G E 2 2 Deployment-related conditions of special surveillance interest MSMR Vol. 23 No. 10 October 2016 Page 2 Obstructive sleep apnea...OSA) is a growing health concern in both civilian and military populations. Individuals who suffer from OSA have increased rates of cardiovascular

  13. Transports under surveillance

    International Nuclear Information System (INIS)

    Jouette, I.

    2016-01-01

    Each year 770.000 nuclear transports are performed in France representing less than 3% of the transport of dangerous materials. This article review various aspects of nuclear transport: modes of transportation, packages, current legislation, safety and surveillance. A map presents the transport route of vitrified wastes from Sellafield plant to the Zwilag storing center in Switzerland at one moment this transport crosses France and another map presents the transport routes involved in the nuclear fuel cycle in France. (A.C.)

  14. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  15. Congenital rubella syndrome surveillance as a platform for surveillance of other congenital infections, Peru, 2004-2007.

    Science.gov (United States)

    Whittembury, Alvaro; Galdos, Jorge; Lugo, María; Suárez-Ognio, Luis; Ortiz, Ana; Cabezudo, Edwin; Martínez, Mario; Castillo-Solórzano, Carlos; Andrus, Jon Kim

    2011-09-01

    Rubella during pregnancy can cause serious fetal abnormalities and death. Peru has had integrated measles/rubella surveillance since 2000 but did not implement congenital rubella syndrome (CRS) surveillance until 2004, in accordance with the Pan American Health Organization recommendations for rubella elimination. The article describes the experience from the CRS sentinel surveillance system in Peru. Peru has maintained a national sentinel surveillance system for reporting confirmed and suspected CRS cases since 2004. A surveillance protocol was implemented with standardized case definitions and instruments in the selected sentinel sites. Each sentinel site completes their case investigations and report forms and sends the reports to the Health Region Epidemiology Department, which forwards the data to the national Epidemiology Department. CRS surveillance data were analyzed for the period 2004-2007. During the period 2004-2007, 16 health facilities, which are located in 9 of the 33 health regions, representing the 3 main geographical areas (coast, mountain, and jungle), were included as sentinel sites for the CRS surveillance. A total of 2061 suspected CRS cases were reported to the system. Of these, 11 were classified as CRS and 23 as congenital rubella infection. Factors significantly associated with rubella vertical transmission were: (1) in the mother, maternal history of rash during pregnancy (odds ratio [OR], 12.0; 95% confidence interval [CI], 3.8-37.8); (2) and in the infant, pigmentary retinopathy (OR, 18.4; 95% CI, 3.2-104.6), purpura (OR, 14.7; 95% CI, 2.8-78.3), and developmental delay (OR, 4.4; 95% CI, 1.75-11.1). The surveillance system has been able to identify rubella vertical transmission, reinforcing the evidence that rubella was a public health problem in Peru. This system may serve as a platform to implement surveillance for other congenital infections in Peru.

  16. Postdischarge surveillance following cesarean section: the incidence of surgical site infection and associated factors.

    Science.gov (United States)

    Cardoso Del Monte, Meire Celeste; Pinto Neto, Aarão Mendes

    2010-08-01

    The rate of surgical site infections (SSI) and their associated risk factors was identified by performing postdischarge surveillance following cesarean section at a public university teaching hospital in Brazil. The study was conducted at the Center for Women's Integrated Health Care in Brazil between May 2008 and March 2009. Women were contacted by telephone 15 and 30 days after cesarean section. During hospitalization, a form was completed on factors associated with post-cesarean SSI. The chi(2) test and Fisher exact test were used to analyze categorical variables and the Mann-Whitney test for numerical variables. Relative risks (RR) and their respective 95% confidence intervals (95% CI) were calculated for factors associated with SSI. P values cesarean section SSI. A 15-day postdischarge follow-up was shown to be sufficient. Hypertension was a factor associated with SSI. Copyright 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  17. Coordinated U. S. PWR Reactor Vessel Surveillance Program: Surveillance Data to Support Long Term Operations

    International Nuclear Information System (INIS)

    Hosler, Ryan; Troyer, Greg; Davidsaver, Sarah; Hardin, Timothy

    2012-01-01

    Irradiated reactor pressure vessel (RPV) surveillance data is used as the basis for embrittlement trend correlations (ETCs) which predict decreases in RP fracture toughness due to irradiation embrittlement. A limited amount of data exists today at fluences that many U. S. PWR RPVs will reach in 60 or more years of operation. However, there is a significant amount of test reactor data available at high fluences, which shows higher embrittlement shifts than the power reactor data-based correlations. A coordinated plan for withdrawal and testing of the U. S. PWR RPV surveillance capsules has been developed, with the intent of filling high fluence gaps in existing PWR data. This paper summarizes the methodology, optimization strategy, and current results of this coordinated U. S. PWR reactor vessel surveillance program (CRVSP). The Coordinated RVSP has been optimized to maximize the quantity and quality of high fluence data while minimizing the burden on the industry

  18. Coverage Probability of Random Intervals

    OpenAIRE

    Chen, Xinjia

    2007-01-01

    In this paper, we develop a general theory on the coverage probability of random intervals defined in terms of discrete random variables with continuous parameter spaces. The theory shows that the minimum coverage probabilities of random intervals with respect to corresponding parameters are achieved at discrete finite sets and that the coverage probabilities are continuous and unimodal when parameters are varying in between interval endpoints. The theory applies to common important discrete ...

  19. Forgetting Curve: Experiments on Intervals and Total Time in Recall

    OpenAIRE

    Ping Zhan; Jeffrey Hanks

    2015-01-01

    This manuscript is a continuation of our previous work ([1], [2]). In [1], we mainly tested the spacing effect and whether intervals affect the recall ratio in recalling English words. From the forgetting curve, learning data like English words and their definitions, it has been assumed that initial intervals should be shorter than later ones. But our experiments showed that the ratio of remembered words is not related to the patterns of intervals, (1) initial intervals shorter than later one...

  20. Support Vector Regression with Interval-Input Interval-Output

    Directory of Open Access Journals (Sweden)

    Wensen An

    2008-12-01

    Full Text Available Support vector machines (classification and regression are powerful machine learning techniques for crisp data. In this paper, the problem is considered for interval data. Two methods to deal with the problem using support vector regression are proposed and two new methods for evaluating performance for estimating prediction interval are presented as well.

  1. Recurrence interval analysis of trading volumes.

    Science.gov (United States)

    Ren, Fei; Zhou, Wei-Xing

    2010-06-01

    We study the statistical properties of the recurrence intervals τ between successive trading volumes exceeding a certain threshold q. The recurrence interval analysis is carried out for the 20 liquid Chinese stocks covering a period from January 2000 to May 2009, and two Chinese indices from January 2003 to April 2009. Similar to the recurrence interval distribution of the price returns, the tail of the recurrence interval distribution of the trading volumes follows a power-law scaling, and the results are verified by the goodness-of-fit tests using the Kolmogorov-Smirnov (KS) statistic, the weighted KS statistic and the Cramér-von Mises criterion. The measurements of the conditional probability distribution and the detrended fluctuation function show that both short-term and long-term memory effects exist in the recurrence intervals between trading volumes. We further study the relationship between trading volumes and price returns based on the recurrence interval analysis method. It is found that large trading volumes are more likely to occur following large price returns, and the comovement between trading volumes and price returns is more pronounced for large trading volumes.

  2. Twelve years of fireworks market surveillance in France

    OpenAIRE

    Branka , Ruddy

    2012-01-01

    International audience; In the view of market surveillance, more than 4400 fireworks have been taken on the spot by sworn people or bought on the market in France since 1999 for inspection purposes. This paper presents the market surveillance sampling evolution during twelve years, carried out by the PYRO unit of the Accidental Risks Division of INERIS as testing body ; the related measures implemented : additional audits in importer plants, interlaboratory tests for guarantying the reliabili...

  3. Interval Entropy and Informative Distance

    Directory of Open Access Journals (Sweden)

    Fakhroddin Misagh

    2012-03-01

    Full Text Available The Shannon interval entropy function as a useful dynamic measure of uncertainty for two sided truncated random variables has been proposed in the literature of reliability. In this paper, we show that interval entropy can uniquely determine the distribution function. Furthermore, we propose a measure of discrepancy between two lifetime distributions at the interval of time in base of Kullback-Leibler discrimination information. We study various properties of this measure, including its connection with residual and past measures of discrepancy and interval entropy, and we obtain its upper and lower bounds.

  4. Twitter Influenza Surveillance: Quantifying Seasonal Misdiagnosis Patterns and their Impact on Surveillance Estimates.

    Science.gov (United States)

    Mowery, Jared

    2016-01-01

    Influenza (flu) surveillance using Twitter data can potentially save lives and increase efficiency by providing governments and healthcare organizations with greater situational awareness. However, research is needed to determine the impact of Twitter users' misdiagnoses on surveillance estimates. This study establishes the importance of Twitter users' misdiagnoses by showing that Twitter flu surveillance in the United States failed during the 2011-2012 flu season, estimates the extent of misdiagnoses, and tests several methods for reducing the adverse effects of misdiagnoses. Metrics representing flu prevalence, seasonal misdiagnosis patterns, diagnosis uncertainty, flu symptoms, and noise were produced using Twitter data in conjunction with OpenSextant for geo-inferencing, and a maximum entropy classifier for identifying tweets related to illness. These metrics were tested for correlations with World Health Organization (WHO) positive specimen counts of flu from 2011 to 2014. Twitter flu surveillance erroneously indicated a typical flu season during 2011-2012, even though the flu season peaked three months late, and erroneously indicated plateaus of flu tweets before the 2012-2013 and 2013-2014 flu seasons. Enhancements based on estimates of misdiagnoses removed the erroneous plateaus and increased the Pearson correlation coefficients by .04 and .23, but failed to correct the 2011-2012 flu season estimate. A rough estimate indicates that approximately 40% of flu tweets reflected misdiagnoses. Further research into factors affecting Twitter users' misdiagnoses, in conjunction with data from additional atypical flu seasons, is needed to enable Twitter flu surveillance systems to produce reliable estimates during atypical flu seasons.

  5. Diagnostic interval and mortality in colorectal cancer

    DEFF Research Database (Denmark)

    Tørring, Marie Louise; Frydenberg, Morten; Hamilton, William

    2012-01-01

    Objective To test the theory of a U-shaped association between time from the first presentation of symptoms in primary care to the diagnosis (the diagnostic interval) and mortality after diagnosis of colorectal cancer (CRC). Study Design and Setting Three population-based studies in Denmark...

  6. Colorimetric tests for diagnosis of filarial infection and vector surveillance using non-instrumented nucleic acid loop-mediated isothermal amplification (NINA-LAMP.

    Directory of Open Access Journals (Sweden)

    Catherine B Poole

    Full Text Available Accurate detection of filarial parasites in humans is essential for the implementation and evaluation of mass drug administration programs to control onchocerciasis and lymphatic filariasis. Determining the infection levels in vector populations is also important for assessing transmission, deciding when drug treatments may be terminated and for monitoring recrudescence. Immunological methods to detect infection in humans are available, however, cross-reactivity issues have been reported. Nucleic acid-based molecular assays offer high levels of specificity and sensitivity, and can be used to detect infection in both humans and vectors. In this study we developed loop-mediated isothermal amplification (LAMP tests to detect three different filarial DNAs in human and insect samples using pH sensitive dyes for enhanced visual detection of amplification. Furthermore, reactions were performed in a portable, non-instrumented nucleic acid amplification (NINA device that provides a stable heat source for LAMP. The efficacy of several strand displacing DNA polymerases were evaluated in combination with neutral red or phenol red dyes. Colorimetric NINA-LAMP assays targeting Brugia Hha I repeat, Onchocerca volvulus GST1a and Wuchereria bancrofti LDR each exhibit species-specificity and are also highly sensitive, detecting DNA equivalent to 1/10-1/5000th of one microfilaria. Reaction times varied depending on whether a single copy gene (70 minutes, O. volvulus or repetitive DNA (40 min, B. malayi and W. bancrofti was employed as a biomarker. The NINA heater can be used to detect multiple infections simultaneously. The accuracy, simplicity and versatility of the technology suggests that colorimetric NINA-LAMP assays are ideally suited for monitoring the success of filariasis control programs.

  7. Guidelines for the medical surveillance of atomic radiation workers

    International Nuclear Information System (INIS)

    1991-11-01

    These guidelines are provided for the use and guidance of occupational physicians concerned with the medical surveillance of atomic radiation workers (ARWs). Persons employed in industries where there is exposure to ionizing radiation should be screened medically for fitness for certain jobs before starting such work and at appropriate intervals while employed. This includes workers at uranium mines, mills and refineries, nuclear fuel fabrication plants, nuclear power plants and research facilities, and facilities using radionuclides in an industrial setting. An important purpose of medical surveillance is to ensure that workers are fit both physically and psychologically to undertake the tasks they may be called upon to perform

  8. Automatic Error Analysis Using Intervals

    Science.gov (United States)

    Rothwell, E. J.; Cloud, M. J.

    2012-01-01

    A technique for automatic error analysis using interval mathematics is introduced. A comparison to standard error propagation methods shows that in cases involving complicated formulas, the interval approach gives comparable error estimates with much less effort. Several examples are considered, and numerical errors are computed using the INTLAB…

  9. Wallops Ship Surveillance System

    Science.gov (United States)

    Smith, Donna C.

    2011-01-01

    Approved as a Wallops control center backup system, the Wallops Ship Surveillance Software is a day-of-launch risk analysis tool for spaceport activities. The system calculates impact probabilities and displays ship locations relative to boundary lines. It enables rapid analysis of possible flight paths to preclude the need to cancel launches and allow execution of launches in a timely manner. Its design is based on low-cost, large-customer- base elements including personal computers, the Windows operating system, C/C++ object-oriented software, and network interfaces. In conformance with the NASA software safety standard, the system is designed to ensure that it does not falsely report a safe-for-launch condition. To improve the current ship surveillance method, the system is designed to prevent delay of launch under a safe-for-launch condition. A single workstation is designated the controller of the official ship information and the official risk analysis. Copies of this information are shared with other networked workstations. The program design is divided into five subsystems areas: 1. Communication Link -- threads that control the networking of workstations; 2. Contact List -- a thread that controls a list of protected item (ocean vessel) information; 3. Hazard List -- threads that control a list of hazardous item (debris) information and associated risk calculation information; 4. Display -- threads that control operator inputs and screen display outputs; and 5. Archive -- a thread that controls archive file read and write access. Currently, most of the hazard list thread and parts of other threads are being reused as part of a new ship surveillance system, under the SureTrak project.

  10. Birth defects surveillance in China.

    Science.gov (United States)

    Dai, Li; Zhu, Jun; Liang, Juan; Wang, Yan-Ping; Wang, He; Mao, Meng

    2011-11-01

    Birth defects are a global public health problem because of their large contribution to infant mortalities and disabilities. It is estimated that 4%-6% of Chinese newborns are affected by birth defects every year. Surveillance is a basic approach to understanding the occurrence and associated factors of birth defects. The Ministry of Health of China initiated a national hospital-based birth defects monitoring system 20 years ago. Nearly every province in this country has established its own surveillance system in the past. The authors reviewed the result of the monitoring system at different administrative levels in China. Available publications on the surveillance of birth defects and data from national and provincial birth defects surveillance systems were reviewed to evaluate the effectiveness of the surveillance systems. According to the 2009 data, the national hospital-based birth defects surveillance system monitored over 1.3 million births, which accounted for more than 8% of births in China. In addition, 30 provincial hospital-based surveillance programs covered a birth population of more than 3.6 million (22% of births in China). Great achievements have been made in terms of case ascertainment, data quality control, and online reporting. But the surveillance systems in China still have some limitations. A short ascertainment period may miss some internal anomalies, inherited metabolic diseases, and malformed fetus aborted before the 28th gestational week. Discrepancies in antenatal or postnatal diagnosis of birth defects between surveillance institutes may affect the detection rate and introduce biases. Absence of baseline data and lack of integrated database systems limit the application of surveillance data to etiological studies and affect the process of decision-making. The surveillance system for birth defects is prerequisite to propose, conduct and assess any interventions for the disease. To meet the need of study and prevention of birth defects

  11. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  12. Internet and Surveillance

    DEFF Research Database (Denmark)

    in this context. With such platforms comes the massive provision and storage of personal data that are systematically evaluated, marketed, and used for targeting users with advertising. In a world of global economic competition, economic crisis, and fear of terrorism after 9/11, both corporations and state...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...

  13. Bodygraphic Injury Surveillance System

    Science.gov (United States)

    Tsuboi, Toshiki; Kitamura, Koji; Nishida, Yoshihumi; Motomura, Yoichi; Takano, Tachio; Yamanaka, Tatsuhiro; Mizoguchi, Hiroshi

    This paper proposes a new technology,``a bodygraphic injury surveillance system (BISS)'' that not only accumulates accident situation data but also represents injury data based on a human body coordinate system in a standardized and multilayered way. Standardized and multilayered representation of injury enables accumulation, retrieval, sharing, statistical analysis, and modeling causalities of injury across different fields such as medicine, engineering, and industry. To confirm the effectiveness of the developed system, the authors collected 3,685 children's injury data in cooperation with a hospital. As new analyses based on the developed BISS, this paper shows bodygraphically statistical analysis and childhood injury modeling using the developed BISS and Bayesian network technology.

  14. GSFC Supplier Surveillance

    Science.gov (United States)

    Kelly, Michael P.

    2011-01-01

    Topics covered include: Develop Program/Project Quality Assurance Surveillance Plans The work activities performed by the developer and/or his suppliers are subject to evaluation and audit by government-designated representatives. CSO supports project by selecting on-site supplier representative s by one of several methods: (1) a Defense Contract Management Agency (DCMA) person via a Letter Of Delegation (LOD), (2) an independent assurance contractor (IAC) via a contract Audits, Assessments, and Assurance (A3) Contract Code 300 Mission Assurance Support Contract (MASC)

  15. INTERVALS OPTIMIZATION OF SYSTEMS INFORMATION SECURITY INSPECTION

    Directory of Open Access Journals (Sweden)

    V. A. Bogatyrev

    2014-09-01

    Full Text Available A Markov model is suggested for secure information systems, functioning under conditions of destructive impacts, which aftereffects are found by on-line and test control. It is assumed that on-line control, in contrast to the test one, is char- acterized by the limited control completeness, but does not require the stopping of computational process. The aim of re- search is to create models that optimize intervals of test control initialization by the criterion of probability maximization for system stay in the ready state to secure fulfillment of the functional requests and minimization of the dangerous system states in view of the uncertainty and intensity variance of the destructive impacts. Variants of testing intervals optimization are con- sidered depending on the intensity of destructive impacts by the criterion of the maximum system availability for the safe execution of queries. Optimization is carried out with and without adaptation to the actual intensity change of destructive impacts. The efficiency of adaptive change for testing periods is shown depending on the observed activity of destructive impacts. The solution of optimization problem is obtained by built-in tools of computer mathematics Mathcad 15, including symbolic mathematics for solution of systems of algebraic equations. The proposed models and methods of determining the optimal testing intervals can find their application in the system design of computer systems and networks of critical applications, working under conditions of destabilizing actions with the increased requirements for their safety.

  16. Boston Collaborative Drug Surveillance Program

    Science.gov (United States)

    The Boston Collaborative Drug Surveillance Program started in 1966 and conducted epidemiologic research to quantify the potential adverse effects of prescription drugs, utilizing in-hospital monitoring.

  17. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  18. Youth Risk Behavior Surveillance System

    Science.gov (United States)

    ... School, Whole Community, Whole Child Tools Health Education Curriculum Analysis Tool (HECAT) HECAT FAQs Health Education Teacher ... Button type="submit" value="Submit" /> Youth Risk Behavior Surveillance ...

  19. The Case for Common Reference Intervals

    Science.gov (United States)

    Jones, Graham RD; Barker, Antony; Tate, Jill; Lim, Chen-Fee; Robertson, Ken

    2004-01-01

    The current paradigm for pathology reference intervals is for each laboratory to determine its own interval for use with each test offered by the laboratory. It is our contention that this approach does not best serve the medical community, especially at a time when electronic databases of health information are being expanded and integrated. We also believe that this approach is not performed well in many laboratories and is excessively expensive in practice. In contrast, we believe that the preferable option is to develop and apply common reference intervals throughout Australia and New Zealand, together with common reporting formats and assay standardisation wherever this is possible. We are aware that these are neither trivial nor simple issues, however we believe that failure to achieve this goal where technically possible will be a failure of the pathology profession to meet the challenges of the modern health community. PMID:18458709

  20. The social dynamics of consent and refusal in HIV surveillance in rural South Africa.

    Science.gov (United States)

    Reynolds, Lindsey; Cousins, Thomas; Newell, Marie-Louise; Imrie, John

    2013-01-01

    In the context of low rates of participation in a prospective, population-based HIV surveillance programme, researchers at a surveillance site in rural KwaZulu-Natal, South Africa, conducted an operational study from January 2009 to February 2010, with the aim of improving participation rates, particularly in the provision of dried blood spots for the surveillance. Findings suggest, firstly, that consent to participation in the HIV surveillance is informed by the dynamics of relationality in the HIV surveillance "consent encounter." Secondly, it emerged that both fieldworkers and participants found it difficult to differentiate between HIV surveillance and HIV testing in the surveillance procedure, and tended to understand and explain giving blood under the aegis of the surveillance as an HIV test. The conflation of surveillance and testing, we argue, is not merely a semantic confusion, but reveals an important tension inherent to global health research between individual risks and benefits and collective good, or between private morality and public good. Because of these structural tensions, we suggest, the HIV surveillance consent encounter activates multiple gift economies in the collection of blood samples. Thinking beyond the complex ethical dimensions provoked by new forms of long-term surveillance and health research, we therefore suggest that deepening relations between scientists, fieldworkers, and study participants in locality deserve more careful methodological consideration and descriptive attention. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Sonoma Persistent Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, D M

    2006-03-24

    Sonoma offers the first cost-effective, broad-area, high-resolution, real-time motion imagery system for surveillance applications. Sonoma is unique in its ability to provide continuous, real-time video imagery of an area the size of a small city with resolutions sufficient to track 8,000 moving objects in the field of view. At higher resolutions and over smaller areas, Sonoma can even track the movement of individual people. The visual impact of the data available from Sonoma is already causing a paradigm shift in the architecture and operation of other surveillance systems. Sonoma is expected to cost just one-tenth the price of comparably sized sensor systems. Cameras mounted on an airborne platform constantly monitor an area, feeding data to the ground for real-time analysis. Sonoma was designed to provide real-time data for actionable intelligence in situations such as monitoring traffic, special events, border security, and harbors. If a Sonoma system had been available in the aftermath of the Katrina and Rita hurricanes, emergency responders would have had real-time information on roads, water levels, and traffic conditions, perhaps saving many lives.

  2. 9975 SHIPPING PACKAGE LIFE EXTENSION SURVEILLANCE PROGRAM RESULTS SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Daugherty, W.; Dunn, K.; Hackney, B.; Hoffman, E.; Skidmore, E.

    2011-01-06

    Results from the 9975 Surveillance Program at the Savannah River Site (SRS) are summarized for justification to extend the life of the 9975 packages currently stored in the K-Area Materials Storage (KAMS) facility from 10 years to 15 years. This justification is established with the stipulation that surveillance activities will continue throughout this extended time to ensure the continued integrity of the 9975 materials of construction and to further understand the currently identified degradation mechanisms. The current 10 year storage life was developed prior to storage. A subsequent report was later used to extend the qualification of the 9975 shipping packages for 2 years for shipping plus 10 years for storage. However the qualification for the storage period was provided by the monitoring requirements of the Storage and Surveillance Program. This report summarizes efforts to determine a new safe storage limit for the 9975 shipping package based on the surveillance data collected since 2005 when the surveillance program began. KAMS is a zero-release facility that depends upon containment by the 9975 to meet design basis storage requirements. Therefore, to confirm the continued integrity of the 9975 packages while stored in KAMS, a 9975 Storage and Surveillance Program was implemented alongside the DOE required Integrated Surveillance Program (ISP) for 3013 plutonium-bearing containers. The 9975 Storage and Surveillance Program performs field surveillance as well as accelerated aging tests to ensure any degradation due to aging, to the extent that could affect packaging performance, is detected in advance of such degradation occurring in the field. The Program has demonstrated that the 9975 package has a robust design that can perform under a variety of conditions. As such the primary emphasis of the on-going 9975 Surveillance Program is an aging study of the 9975 Viton(reg.sign) GLT containment vessel O-rings and the Celotex(reg.sign) fiberboard thermal

  3. Advanced neutron source materials surveillance program

    International Nuclear Information System (INIS)

    Heavilin, S.M.

    1995-01-01

    The Advanced Neutron Source (ANS) will be composed of several different materials, one of which is 6061-T6 aluminum. Among other components, the reflector vessel and the core pressure boundary tube (CPBT), are to be made of 6061-T6 aluminum. These components will be subjected to high thermal neutron fluences and will require a surveillance program to monitor the strength and fracture toughness of the 6061-T6 aluminum over their lifetimes. The purpose of this paper is to explain the steps that were taken in the summer of 1994 toward developing the surveillance program. The first goal was to decide upon standard specimens to use in the fracture toughness and tensile testing. Second, facilities had to be chosen for specimens representing the CPBT and the reflector vessel base, weld, and heat-affected-zone (HAZ) metals. Third, a timetable had to be defined to determine when to remove the specimens for testing

  4. Return Intervals Approach to Financial Fluctuations

    Science.gov (United States)

    Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H. Eugene

    Financial fluctuations play a key role for financial markets studies. A new approach focusing on properties of return intervals can help to get better understanding of the fluctuations. A return interval is defined as the time between two successive volatilities above a given threshold. We review recent studies and analyze the 1000 most traded stocks in the US stock markets. We find that the distribution of the return intervals has a well approximated scaling over a wide range of thresholds. The scaling is also valid for various time windows from one minute up to one trading day. Moreover, these results are universal for stocks of different countries, commodities, interest rates as well as currencies. Further analysis shows some systematic deviations from a scaling law, which are due to the nonlinear correlations in the volatility sequence. We also examine the memory in return intervals for different time scales, which are related to the long-term correlations in the volatility. Furthermore, we test two popular models, FIGARCH and fractional Brownian motion (fBm). Both models can catch the memory effect but only fBm shows a good scaling in the return interval distribution.

  5. Seismic Surveillance. Nuclear Test Ban Verification

    Science.gov (United States)

    1990-02-26

    Laboratory Southern Methodist University Dallas, TX 75275 -3- OTHERS (United States) Dr. Monem Abdel-Gawad Dr. G.A. Bollinger Rockwell International Science...Sciences Institute of Advanced Studies G.P.O. Box 4 Canberra 2601, AUSTRALIA Dr. Bernard Massinon Societe Radiomana 27 rue Claude Bernard 75005 Paris ...FRANCE (2 Copies) Dr. Pierre Mecheler Societe Radiomana 27 rue Claude Bernard 75005 Paris , FRANCE Dr. Svein Mykkeltveit NTNF/NORSAR P.O. Box 51 N-2007

  6. Surveillance of industrial processes with correlated parameters

    Science.gov (United States)

    White, Andrew M.; Gross, Kenny C.; Kubic, William L.; Wigeland, Roald A.

    1996-01-01

    A system and method for surveillance of an industrial process. The system and method includes a plurality of sensors monitoring industrial process parameters, devices to convert the sensed data to computer compatible information and a computer which executes computer software directed to analyzing the sensor data to discern statistically reliable alarm conditions. The computer software is executed to remove serial correlation information and then calculate Mahalanobis distribution data to carry out a probability ratio test to determine alarm conditions.

  7. Vascular access surveillance: case study of a false paradigm.

    Science.gov (United States)

    Paulson, William D; Moist, Louise; Lok, Charmaine E

    2013-01-01

    The hemodialysis vascular access surveillance controversy provides a case study of how enthusiasm for a new test or treatment can lead to adoption of a false paradigm. Paradigms are the beliefs and assumptions shared by those in a field of knowledge, and are commonly included in clinical practice guidelines. The guidelines of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommend that arteriovenous vascular accesses undergo routine surveillance for detection and correction of stenosis. This recommendation is based on the paradigm that surveillance of access blood flow or dialysis venous pressure combined with correction of stenosis improves access outcomes. However, the quality of evidence that supports this paradigm has been widely criticized. We tested the validity of the surveillance paradigm by applying World Health Organization (WHO) criteria for evaluating screening tests to a literature review of published vascular access studies. These criteria include four components: undesired condition, screening test, intervention, and desired outcome. The WHO criteria show that surveillance as currently practiced fails all four components and provides little or no significant benefit, suggesting that surveillance is a false paradigm. Once a paradigm is established, however, challenges to its validity are usually resisted even as new evidence indicates the paradigm is not valid. Thus, it is paramount to apply rigorous criteria when developing guidelines. Regulators may help promote needed changes in paradigms when cost and safety considerations coincide. © 2013 Wiley Periodicals, Inc.

  8. Supplementary surveillance programme for WWER-440 reactor pressure vessels

    International Nuclear Information System (INIS)

    Brumovsky, M.; Novosad, P.

    1994-01-01

    Paper gives a short analysis of a standard surveillance program for WWER440/213 type reactor pressure vessels. The program suggests the surveillance specimens are located in the region of high lead factor and thus they are suitable for surveillance for only up to about 5 years. For better and effective use of the results, their re-evaluation, based on gamma scanning of irradiated specimens as well as on testing of reconstituted irradiated specimens with the goal to determine the static and dynamic fracture toughness has been opened. New, supplementary surveillance program for the vessels operated in Czech Republic was designed: archive pieces of specimens (for further reconstitution after irradiation) will be irradiated in sites with low lead factor and then tested to determine the standard (impact) and fracture toughnesses

  9. Contrasting Diversity Values: Statistical Inferences Based on Overlapping Confidence Intervals

    Science.gov (United States)

    MacGregor-Fors, Ian; Payton, Mark E.

    2013-01-01

    Ecologists often contrast diversity (species richness and abundances) using tests for comparing means or indices. However, many popular software applications do not support performing standard inferential statistics for estimates of species richness and/or density. In this study we simulated the behavior of asymmetric log-normal confidence intervals and determined an interval level that mimics statistical tests with P(α) = 0.05 when confidence intervals from two distributions do not overlap. Our results show that 84% confidence intervals robustly mimic 0.05 statistical tests for asymmetric confidence intervals, as has been demonstrated for symmetric ones in the past. Finally, we provide detailed user-guides for calculating 84% confidence intervals in two of the most robust and highly-used freeware related to diversity measurements for wildlife (i.e., EstimateS, Distance). PMID:23437239

  10. Reference intervals for the P-Albumin bromocresol purple method.

    Science.gov (United States)

    Christensen, Peter Astrup

    2017-10-01

    Correct reference intervals are an important part of test results. As establishing own reference intervals is a very expensive task, the NORIP reference intervals are often transferred for use in Nordic laboratories. The NORIP reference interval on P-Albumin was here compared to current results for laboratories using the bromocresol purple (BCP) method for P-Albumin. External quality control reports were used to investigate the change in levels between the BCP and BCG methods on P-Albumin. An algorithm was built for extracting and isolating the laboratory's healthy subject population. The algorithm was used to extract test results from the laboratory information system. Parametric and non-parametric statistical methods were used to evaluate the P-Albumin test result populations. The indirect method used here clearly shows that the NORIP reference intervals for P-Albumin are not fit for the current bromocresol purple methods. The method was also used to suggest new reference interval limits.

  11. Reference intervals data mining: no longer a probability paper method.

    Science.gov (United States)

    Katayev, Alexander; Fleming, James K; Luo, Dajie; Fisher, Arren H; Sharp, Thomas M

    2015-01-01

    To describe the application of a data-mining statistical algorithm for calculation of clinical laboratory tests reference intervals. Reference intervals for eight different analytes and different age and sex groups (a total of 11 separate reference intervals) for tests that are unlikely to be ordered during routine screening of disease-free populations were calculated using the modified algorithm for data mining of test results stored in the laboratory database and compared with published peer-reviewed studies that used direct sampling. The selection of analytes was based on the predefined criteria that include comparability of analytical methods with a statistically significant number of observations. Of the 11 calculated reference intervals, having upper and lower limits for each, 21 of 22 reference interval limits were not statistically different from the reference studies. The presented statistical algorithm is shown to be an accurate and practical tool for reference interval calculations. Copyright© by the American Society for Clinical Pathology.

  12. Surveillance of healthcare-associated infection in hospitalised South African children: Which method performs best?

    Directory of Open Access Journals (Sweden)

    A Dramowski

    2017-01-01

    Full Text Available Background. In 2012, the South African (SA National Department of Health mandated surveillance of healthcare-associated infection (HAI, but made no recommendations of appropriate surveillance methods. Methods. Prospective clinical HAI surveillance (the reference method was conducted at Tygerberg Children’s Hospital, Cape Town, from 1 May to 31 October 2015. Performance of three surveillance methods (point prevalence surveys (PPSs, laboratory surveillance and tracking of antimicrobial prescriptions was compared with the reference method using surveillance evaluation guidelines. Factors associated with failure to detect HAI were identified by logistic regression analysis. Results. The reference method detected 417 HAIs among 1 347 paediatric hospitalisations (HAI incidence of 31/1000 patient days; 95% confidence interval (CI 28.2 - 34.2. Surveillance methods had variable sensitivity (S and positive predictive value (PPV: PPS S = 24.9% (95% CI 21 - 29.3, PPV = 100%; laboratory surveillance S = 48.4% (95% CI 43.7 - 53.2, PPV = 55.2% (95% CI 50.1 - 60.2; and antimicrobial prescriptions S = 66.4% (95% CI 61.8 - 70.8%, PPV = 88.5% (95% CI 84.5 - 91.6. Combined laboratory-antimicrobial surveillance achieved superior HAI detection (S = 84.7% (95% CI 80.9 - 87.8%, PPV = 97% (95% CI 94.6 - 98.4%. Factors associated with failure to detect HAI included patient transfer (odds ratio (OR 2.0, single HAI event (OR 2.8, age category 1 - 5 years (OR 2.1 and hospitalisation in a general ward (OR 2.3. Conclusions. Repeated PPSs, laboratory surveillance and/or antimicrobial prescription tracking are feasible HAI surveillance methods for low-resource settings. Combined laboratory-antimicrobial surveillance achieved the best sensitivity and PPV. SA paediatric healthcare facilities should individualise HAI surveillance, selecting a method suited to available resources and practice context.

  13. Police surveillance and driving speed.

    NARCIS (Netherlands)

    2008-01-01

    Although speed plays a large part in the occurrence of crashes, drivers often exceed the speed limit. The police use various methods when carrying out their speed surveillance. In the Netherlands positive effects have been found of speed surveillance with radar cars (without stopping). It is to be

  14. Reporting and Surveillance for Norovirus Outbreaks

    Science.gov (United States)

    ... Vaccine Surveillance Network (NVSN) Foodborne Diseases Active Surveillance Network (FoodNet) National Outbreak Reporting System (NORS) Estimates of Foodborne Illness in the United States CDC's Vessel Sanitation Program CDC Feature: Surveillance for Norovirus Outbreaks Top ...

  15. Surveillance theory and its implications for law

    NARCIS (Netherlands)

    Timan, Tjerk; Galic, Masa; Koops, Bert-Jaap; Brownsword, Roger; Scotford, Eloise; Yeung, Karen

    2017-01-01

    This chapter provides an overview of key surveillance theories and their implications for law and regulation. It presents three stages of theories that characterise changes in thinking about surveillance in society and the disciplining, controlling, and entertaining functions of surveillance.

  16. VNIIEF NMPC and A Maintenance Management Conference video surveillance

    International Nuclear Information System (INIS)

    Malone, T.

    1997-08-01

    This paper is part of ongoing Nuclear Materials Protection, Control and Accountability (NMPC and A) work with the All Russian Scientific Research Institute of Experimental Physics (VNIIEF), Sarov, Russia. The material presented in the paper is to provide guidance for the preparation of maintenance management for NMPC and A video assessment and surveillance subsystems being installed at VNIIEF. This paper discusses maintenance philosophies, performance testing, equipment inspection/setup, and record keeping for a video assessment and surveillance subsystem

  17. A generic rabies risk assessment tool to support surveillance.

    Science.gov (United States)

    Ward, Michael P; Hernández-Jover, Marta

    2015-06-01

    The continued spread of rabies in Indonesia poses a risk to human and animal populations in the remaining free islands, as well as the neighbouring rabies-free countries of Timor Leste, Papua New Guinea and Australia. Here we describe the development of a generic risk assessment tool which can be used to rapidly determine the vulnerability of rabies-free islands, so that scarce resources can be targeted to surveillance activities and the sensitivity of surveillance systems increased. The tool was developed by integrating information on the historical spread of rabies, anthropological studies, and the opinions of local animal health experts. The resulting tool is based on eight critical parameters that can be estimated from the literature, expert opinion, observational studies and information generated from routine surveillance. In the case study presented, results generated by this tool were most sensitive to the probability that dogs are present on private and fishing boats and it was predicted that rabies-infection (one infected case) might occur in a rabies-free island (upper 95% prediction interval) with a volume of 1000 boats movements. With 25,000 boat movements, the median of the probability distribution would be equal to one infected case, with an upper 95% prediction interval of six infected cases. This tool could also be used at the national-level to guide control and eradication plans. An initial recommendation from this study is to develop a surveillance programme to determine the likelihood that boats transport dogs, for example by port surveillance or regularly conducted surveys of fisherman and passenger ferries. However, the illegal nature of dog transportation from rabies-infected to rabies-free islands is a challenge for developing such surveillance. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The critical role of acute flaccid paralysis surveillance in the Global Polio Eradication Initiative.

    Science.gov (United States)

    Tangermann, Rudolf H; Lamoureux, Christine; Tallis, Graham; Goel, Ajay

    2017-05-01

    Acute flaccid paralysis (AFP) surveillance is a key strategy used by the Global Polio Eradication Initiative (GPEI) to measure progress towards reaching the global eradication goal. Supported by a global polio laboratory network, AFP surveillance is conducted in 179 of 194 WHO member states. Active surveillance visits to priority health facilities are used to assure all children <15 years with AFP are detected, followed by stool specimen collection and testing for poliovirus in WHO-accredited polio laboratories. The quality of AFP surveillance is regularly monitored with standardized surveillance quality indicators. In highest risk countries and areas, the sensitivity of AFP surveillance is enhanced by environmental surveillance (testing of sewage samples). Genetic sequencing of detected poliovirus isolates yields programmatically important information on polio transmission pathways. AFP surveillance is one of the most valuable assets of the GPEI, with the potential to serve as a platform to build integrated disease surveillance systems. Continued support to maintain AFP surveillance systems will be essential, to reliably monitor the completion of global polio eradication, and to assure that a key resource for building surveillance capacity is transitioned post-eradication to support other health priorities. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Self-surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    coupled with social interaction and sometimes framed as entertainment or games. Facilitated by online community and social networking sites, the possibility of collecting and sharing data is a significant feature of these self-monitoring technologies. They all include sharing features where weight, blood...... pressure, fitness activities, sleep cycles, etc. can be broadcasted, e.g. as tweets on Twitter or status updates on Facebook. Such quantification practices with monitoring technologies become co-producing when individuals constitute themselves as subjects engaging in self-tracking, self-care, and self......Gadgets and applications are increasingly being developed and used for tracking, quantifying, and documenting everyday life activities and especially health and fitness devices such as GPS-enabled sports watches are well-known and popular. However, self-surveillance practices involving networked...

  20. Total process surveillance: (TOPS)

    International Nuclear Information System (INIS)

    Millar, J.H.P.

    1992-01-01

    A Total Process Surveillance system is under development which can provide, in real-time, additional process information from a limited number of raw measurement signals. This is achieved by using a robust model based observer to generate estimates of the process' internal states. The observer utilises the analytical reduncancy among a diverse range of transducers and can thus accommodate off-normal conditions which lead to transducer loss or damage. The modular hierarchical structure of the system enables the maximum amount of information to be assimilated from the available instrument signals no matter how diverse. This structure also constitutes a data reduction path thus reducing operator cognitive overload from a large number of varying, and possibly contradictory, raw plant signals. (orig.)

  1. Secure surveillance videotapes

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.; Olsen, R.; Chitumbo, K.; Pepper, S.

    1995-01-01

    With assistance from the US Program for Technical Assistance to IAEA Safeguards (POTAS), Aquila Technologies Group developed the Tamper-Resistant Analog Media (TRAM-1000) system to provide standard VHS surveillance video tapes with an enhanced tamper-indicating capability. This project represents further implementation of the partnership approach in facilities including light water reactors with MOX facilities. These facilities use Uniplex Digiquad system video tapes. The partnership approach ensures that one organization can exchange the tapes in a machine without the presence of the other, without losing continuity of information. The TRAM-1000 system development project was accomplished in two stages. In the first stage of the project, the original system delivered to the IAEA, consists of three parts: (1) the tamper detection unit, (2) a specially augmented VHS video tape, and (3) an HP-95 reader. The tamper detection unit houses a VACOSS active fiber-optic seal and an electronic identification tag (E-TAG) reader. In the second stage of the project, the original TRAM-1000 was modified to its current design based on agency input. After delivery of the original TRAM-1000 system to the IAEA, it was reviewed by inspectors. The inspectors felt that the initial system's tape storage/transport method could be simplified. Rather than threading the fiber through the tape spindles, the inspectors suggested that the tape be placed in a bag capable of being sealed. Also, a more flexible fiber-optic cable was recommended. As a result of these suggestions, Aquila developed a tamper-proof bag specifically for holding a surveillance video tape and sealable with a VACOSS fiber optical seal

  2. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-02-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  3. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-03-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  4. Surveillance of environmental radiation in Finland. Annual report 2011

    International Nuclear Information System (INIS)

    Mustonen, R.

    2012-08-01

    and soil in the Member States. In Finland, also the Finnish Meteorological Institute (FMI) and the Defence Forces are monitoring environmental radiation at their own stations. Research and Environmental Surveillance Department (TKO) at STUK is a testing laboratory accredited by FINAS (Finnish Accreditation Service) under the registration number T167. The laboratory meets the requirements laid down in standard EN ISO / IEC 17025:2005. Almost all analyses in the radiation surveillance programme are made according to the accreditation requirements. STUK's partners in surveillance of environmental radioactivity are collecting and delivering environmental samples for laboratory analyses, or are participating in whole-body counting

  5. Surveillance of Tuberculosis in Taipei: The Influence of Nontuberculous Mycobacteria.

    Science.gov (United States)

    Chiang, Chen-Yuan; Yu, Ming-Chih; Yang, Shiang-Lin; Yen, Muh-Yong; Bai, Kuan-Jen

    2015-01-01

    Notification of tuberculosis (TB) but not nontuberculous mycobacteria (NTM) is mandatory in Taiwan. Partly due to the strict regulation on TB notification, several patients infected with NTM were notified as TB cases. Notification of patients infected with NTM as TB cases can trigger public health actions and impose additional burdens on the public health system. We conducted a study to assess the influence of NTM infection on surveillance of TB in Taipei. The study population included all individuals with a positive culture for Mycobacterium who were citizens of Taipei City and notified as TB cases in the calendar years 2007-2010. Of the 4216 notified culture-positive tuberculosis (TB) cases, 894 (21.2%) were infected with NTM. The average annual reported case rate of infection with NTM was 8.6 (95% confidence interval 7.7-9.4) per 100,000 people. The reported case rate of NTM increased with age in both males and females. The proportion of reported TB cases infected with NTM was significantly higher in females than in males (27.6% vs 17.8%, adjusted OR (adjOR) 1.93, 95% confidence interval (CI) 1.63-2.28); in smear-positive than in smear-negative (23.1% vs 19.2%, adjOR 1.26, 95% CI 1.08-1.47); and in previously treated cases than in new cases (35.7% vs 19.1%, adjOR 2.30, 95% CI 1.88-2.82). The most frequent species was M. avium complex (32.4%), followed by M. chelonae complex (17.6%), M. fortuitum complex (17.0%) and M. kansasii (9.8%). Of the 890 notified NTM cases assessed, 703 (79.0%) were treated with anti-TB drugs, and 730 (82.0%) were de-notified. The influence of NTM on surveillance of TB in Taipei was substantial. Health authorities should take action to ensure that nucleic acid amplification tests are performed in all smear-positive cases in a timely manner to reduce the misdiagnosis of patients infected with NTM as TB cases.

  6. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  7. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal of this paper is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  8. A New Molecular Surveillance System for Leishmaniasis

    Science.gov (United States)

    Pandey, Kishor; Pandey, Basu Dev; Mallik, Arun Kumar; Acharya, Jyoti; Kato, Kentaro; Kaneko, Osamu; Ferreira, Pedro Eduardo

    2014-01-01

    Abstract. Presently, global efforts are being made to control and eradicate the deadliest tropical diseases through the improvement of adequate interventions. A critical point for programs to succeed is the prompt and accurate diagnosis in endemic regions. Rapid diagnostic tests (RDTs) are being massively deployed and used to improve diagnosis in tropical countries. In the present report, we evaluated the hypothesis of, after use for diagnosis, the reuse of the Leishmania RDT kit as a DNA source, which can be used downstream as a molecular surveillance and/or quality control tool. As a proof of principle, a polymerase chain reaction-based method was used to detect Leishmania spp. minicircle kinetoplast DNA from leishmaniasis RDT kits. Our results show that Leishmania spp. DNA can be extracted from used RDTs and may constitute an important, reliable, and affordable tool to assist in future leishmaniasis molecular surveillance methods. PMID:24752687

  9. Perception of short time scale intervals in a hypnotic virtuoso.

    Science.gov (United States)

    Noreika, Valdas; Falter, Christine M; Arstila, Valtteri; Wearden, John H; Kallio, Sakari

    2012-01-01

    Previous studies showed that hypnotized individuals underestimate temporal intervals in the range of several seconds to tens of minutes. However, no previous work has investigated whether duration perception is equally disorderly when shorter time intervals are probed. In this study, duration perception of a hypnotic virtuoso was tested using repeated standard temporal generalization and duration estimation tasks. When compared to the baseline state, hypnosis affected perception of intervals spread around 600 ms in the temporal generalization task but did not alter perception of slightly longer intervals spread around 1000 ms. Furthermore, generalization of temporal intervals was more orderly under hypnosis than in the baseline state. In contrast, the hypnotic virtuoso showed a typical time underestimation effect when perception of longer supra-second intervals was tested in the duration estimation task, replicating results of the previous hypnosis studies.

  10. Inverse Interval Matrix: A Survey

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří; Farhadsefat, R.

    2011-01-01

    Roč. 22, - (2011), s. 704-719 E-ISSN 1081-3810 R&D Projects: GA ČR GA201/09/1957; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : interval matrix * inverse interval matrix * NP-hardness * enclosure * unit midpoint * inverse sign stability * nonnegative invertibility * absolute value equation * algorithm Subject RIV: BA - General Mathematics Impact factor: 0.808, year: 2010 http://www.math.technion.ac.il/iic/ela/ela-articles/articles/vol22_pp704-719.pdf

  11. Identification et surveillance des individus

    OpenAIRE

    Aghroum, Christian; Alberganti, Michel; Bonelli, Laurent; Ceyhan, Ayse; Denis, Vincent; Dufief, Vincent; Laurent, Sébastien; Piazza, Pierre; Preuss-Laussinotte, Sylvia; Rousselin, Thierry; Thorel, Jérôme; Tsoukala, Anastassia; Vitran, Jean-Claude; Alberganti, Michel; Alberganti, Michel

    2014-01-01

    « Big Brother is watching you ! » Cet avertissement placardé sur les murs de la cité imaginaire d'Océania dans le roman 1984 de Georges Orwell peut-il s'appliquer à nos sociétés contemporaines ? Passeport biométrique, fichage informatisé des individus, multiplication des caméras de surveillance, utilisation de puce dans des objets de la vie quotidienne, ou pour suivre les criminels en liberté surveillée, les mesures d'identification, de fichage et de surveillance des individus par des techniq...

  12. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico; Definicion de la longitud minima de inserto en la reconstitucion de probetas Charpy para vigilancia y extension de vida de vasijas en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M., E-mail: jesus.romero@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm{sup 3} in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  13. Surveillance of items important to safety in nuclear power plants

    International Nuclear Information System (INIS)

    1982-01-01

    This Safety Guide provides guidance and recommendations on surveillance activities to ensure that structures, systems and components important to safety are available to perform their functions in accordance with design intent and assumptions. Surveillance includes planned activities carried out to verify that the plant is operated within the prescribed operational limits and conditions, and to detect in time any deterioration of structures, systems and components that could result in an unsafe condition. These activities can be classified as: 1) Monitoring plant parameters and system status; 2) Checking and calibrating instrumentation; 3) Testing and inspecting structures, systems and components; 4) Evaluating the results of items 1) and 3). All the activities mentioned above are covered in this Guide. Collectively, such activities are referred to as the surveillance programme. Also covered are requirements and recommendations defining the basis and extent of the surveillance programme, and the administrative and technical aspects of its development and implementation

  14. Performance of Syphilis Sentinel Surveillance in the context of endemic Treponematoses: experience from Ghana.

    Science.gov (United States)

    Dassah, Edward Tieru; Adu-Sarkodie, Yaw; Mayaud, Philippe

    2016-12-09

    Use of treponemal tests to screen for syphilis (caused by Treponema pallidum pallidum) poses challenges with infection status classification, especially in settings where other treponemal infections are endemic. This study aimed to determine the validity of the syphilis surveillance testing strategy implemented since 2004 using two treponemal tests, and estimate the seroprevalence of active syphilis infection in Ghana where yaws (caused by Treponema pallidum pertenue) is endemic. We retested sera from the 2007 HIV sentinel survey (HSS) using a traditional algorithm, quantitative rapid plasma reagin test followed by qualitative Treponema pallidum haemagglutination assay. The adjusted seroprevalence of active syphilis was calculated by applying the proportions of active syphilis within identified categories of HSS samples during the retesting, to the entire population of HSS samples. The 95% confidence intervals (CIs) were calculated for each proportion, and the t-test was used to assess differences in proportions. Of 2,214 samples that were retested, 203 (9.2%) had active syphilis infection, 21 (0.9%) were biological false reactions, 640 (28.9%) were past or treated syphilis infections, and 1,350 (61%) were uninfected. The current syphilis testing strategy overestimated the seroprevalence of active syphilis infection by a third (HSS versus traditional algorithm: 6.0% (95% CI: 5.6-6.3) vs. 4.5% (95% CI: 4.2-4.8); p syphilis infection. More than half (51.9%) of HSS syphilis positive cases were actually past/treated treponemal infections, possibly previous exposure to yaws. There is an urgent need to review the current syphilis sentinel surveillance testing strategy in Ghana in the context of concurrent endemic treponematoses, to better inform policy.

  15. [HIV sentinel surveillance of pregnant women in Mauritania from 2001 to 2007].

    Science.gov (United States)

    Fall-Malick, F Z; Bara, A O; Lam, M; Mint Beibacar, M; Ba, K; Ba, H; Ould Ghady, I; Ould Horma, A; Toure-Kane, N C; Mboup, S; Lo, B

    2010-10-01

    According to the 2008 report on global AIDS epidemic, 33 millions of people are living with HIV/AIDS. Subsaharian Africa is the most affected part of the world. The first case of AIDS in Mauritania was reported in 1987. The national prevalence of HIV/AIDS in the country is estimated at less than 1%. The HIV serosurveillance among pregnant women started in country in 2001. This work has focused on HIV sentinel surveillance among pregnant women in antenatal clinics, attending health centres in different wilayas (regions) of the country in order to assess evolution of prevalence between 2001 and 2007. An anonymous and non-correlated method is used for this survey. A questionnaire was administered and venous sampling made for eligible women. Analyses were performed with an algorithm based on two screening tests (ELISA) and another test for confirmation (New Lav Blot). Despite some disparities between the sites considered, the results have shown a low prevalence rate (between 0.1 and 1.48). The average prevalence of HIV infection samples collected increased from 0.57% [0.34-0.80] in 2001 to 0.61% [0.40-0.82] in 2007 with 95% confidence interval. Statistical analysis showed no significant changes between 2001 and 2007 at all these sites. HIV1 is the most frequent type with a proportion of 93.5% in 2007. After several years of classic HIV sentinel surveillance, and to better understand disparities between sites, we recommend a second generation sentinel surveillance (behavioural and serological) approach.

  16. Chaotic dynamics from interspike intervals

    DEFF Research Database (Denmark)

    Pavlov, A N; Sosnovtseva, Olga; Mosekilde, Erik

    2001-01-01

    Considering two different mathematical models describing chaotic spiking phenomena, namely, an integrate-and-fire and a threshold-crossing model, we discuss the problem of extracting dynamics from interspike intervals (ISIs) and show that the possibilities of computing the largest Lyapunov expone...

  17. Interval matrices: Regularity generates singularity

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří; Shary, S.P.

    2018-01-01

    Roč. 540, 1 March (2018), s. 149-159 ISSN 0024-3795 Institutional support: RVO:67985807 Keywords : interval matrix * regularity * singularity * P-matrix * absolute value equation * diagonally singilarizable matrix Subject RIV: BA - General Mathematics Impact factor: 0.973, year: 2016

  18. Dynamic Properties of QT Intervals

    Czech Academy of Sciences Publication Activity Database

    Halámek, Josef; Jurák, Pavel; Vondra, Vlastimil; Lipoldová, J.; Leinveber, Pavel; Plachý, M.; Fráňa, P.; Kára, T.

    2009-01-01

    Roč. 36, - (2009), s. 517-520 ISSN 0276-6574 R&D Projects: GA ČR GA102/08/1129; GA MŠk ME09050 Institutional research plan: CEZ:AV0Z20650511 Keywords : QT Intervals * arrhythmia diagnosis Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://cinc.mit.edu/archives/2009/pdf/0517.pdf

  19. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... in this context. With such platforms comes the massive provision and storage of personal data that are systematically evaluated, marketed, and used for targeting users with advertising. In a world of global economic competition, economic crisis, and fear of terrorism after 9/11, both corporations and state...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...

  20. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to identify episodes of local transmission and to guide prevention recommendations for travelers. This report summarizes cases in persons with onset of illness in 2014 and trends during previous years. Malaria cases diagnosed by blood film, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System, National Notifiable Diseases Surveillance System, or direct CDC consultations. CDC conducts antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. Data from these reporting systems serve as the basis for this report. CDC received reports of 1,724 confirmed malaria cases, including one congenital case and two cryptic cases, with onset of symptoms in 2014 among persons in the United States. The number of confirmed cases in 2014 is consistent with the number of confirmed cases reported in 2013 (n = 1,741; this number has been updated from a previous publication to account for delayed reporting for persons with symptom onset occurring in late 2013). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 66.1%, 13.3%, 5.2%, and 2.7% of cases, respectively

  1. Radioisotopic Thermoelectric Generator (RTG) Surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Mulford, Roberta Nancy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-29

    This lecture discusses stockpile stewardship efforts and the role surveillance plays in the process. Performance of the RTGs is described, and the question of the absence of anticipated He is addressed.

  2. Haematological reference intervals in a multiethnic population.

    Directory of Open Access Journals (Sweden)

    Angeli Ambayya

    Full Text Available Similar to other populations, full blood count reference (FBC intervals in Malaysia are generally derived from non-Malaysian subjects. However, numerous studies have shown significant differences between and within populations supporting the need for population specific intervals.Two thousand seven hundred twenty five apparently healthy adults comprising all ages, both genders and three principal races were recruited through voluntary participation. FBC was performed on two analysers, Sysmex XE-5000 and Unicel DxH 800, in addition to blood smears and haemoglobin analysis. Serum ferritin, soluble transferrin receptor and C-reactive protein assays were performed in selected subjects. All parameters of qualified subjects were tested for normality followed by determination of reference intervals, measures of central tendency and dispersion along with point estimates for each subgroup.Complete data was available in 2440 subjects of whom 56% (907 women and 469 men were included in reference interval calculation. Compared to other populations there were significant differences for haemoglobin, red blood cell count, platelet count and haematocrit in Malaysians. There were differences between men and women, and between younger and older men; unlike in other populations, haemoglobin was similar in younger and older women. However ethnicity and smoking had little impact. 70% of anemia in premenopausal women, 24% in postmenopausal women and 20% of males is attributable to iron deficiency. There was excellent correlation between Sysmex XE-5000 and Unicel DxH 800.Our data confirms the importance of population specific haematological parameters and supports the need for local guidelines rather than adoption of generalised reference intervals and cut-offs.

  3. Selecting clinically relevant populations for reference intervals.

    Science.gov (United States)

    Ritchie, Robert F; Palomaki, Glenn

    2004-01-01

    The selection of individuals to represent a group for any purpose can commit the effort to success or failure from the very outset. The description of this group must reflect what is, in reality, the purpose for which the group is being studied. Considering that reference intervals are designed to assist clinicians during diagnostic triage, criteria must reflect the nature of the subjects entering the system for care. The majority of people seeking care have non-life-threatening, yet troublesome complaints. In other words, persons who are in a reasonable state of health and who are not suffering from significant illness. Therefore the relevant cohort should fit this description, not individuals who lack any clinical or laboratory issues. Our focus is to employ reference intervals to exclude disease and not to define normality. Normality in the eyes of statisticians is quite different from the word as viewed by clinical staff, yet the term is used interchangeably without concern for its ultimate use. As a result medicine today stumbles over this issue at every turn. Scientists and artists do not speak the same language. Compounding this awkward situation has been the conviction that by increasing laboratory precision and accuracy, the utility of laboratory data, reference intervals in particular, will improve clinical understanding. This has, after many years, not proven to be the case. What has become very evident, however, is that unsustainably large sums of money are being devoted to improving laboratory performance. To what end, when we are unable to grasp the significance of what is available now including published reference intervals for common test values? A realistic perspective on the value of prevailing laboratory performance, as illustrated by reference intervals, must be adopted. The obligation of laboratories, its regulators and professional groups is to create a sustainable mechanism to provide clinically usable information, in a timely and affordable

  4. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  5. Health surveillance - myth and reality

    International Nuclear Information System (INIS)

    Sharp, C.

    1998-01-01

    This paper discusses the principles, health benefit and cost-effectiveness of health surveillance in the occupational setting, which apply to exposure to ionising radiations in the same manner as to other hazards in the workplace. It highlights the techniques for undertaking health surveillance, discusses their relative advantages and disadvantages and illustrates these in relation to specific hazards. The responsibilities of the medical staff and of the worker are also discussed. (author)

  6. Video Surveillance in the Cloud?

    OpenAIRE

    Neal, DJ; Rahman, Shawon

    2015-01-01

    A high-resolution video surveillance management system incurs huge amounts of storage and network bandwidth. The current infrastructure required to support a high resolution video surveillance management system (VMS) is expensive and time consuming to plan, implement and maintain. With the recent advances in cloud technologies, opportunity for the utilization of virtualization and the opportunity for distributed computing techniques of cloud storage have been pursued on the basis to find out ...

  7. Occupational Surveillance for Spaceflight Exposures

    Science.gov (United States)

    Tarver, William J.

    2010-01-01

    This slide presentation reviews the importance of longterm occupational health surveillance of astronauts after exposure to the possible hazards of spaceflight. Because there is not much information about long term effects of spaceflight on human health, it is important to identify some of the possible results of exposure to the many possible factors that can influence longterm health impacts. This surveillance also allows for NASA to meet the obligation to care for the astronauts for their lifetime.

  8. Evaluation of Healing Intervals of Incisional Skin Wounds of Goats ...

    African Journals Online (AJOL)

    The aim of this study was to compare the healing intervals among simple interrupted (SI), ford interlocking (FI) and subcuticular (SC) suture patterns in goats. We hypothesized that these common suture patterns used for closure of incisional skin wounds may have effect on the healing interval. To test this hypothesis, two ...

  9. Confidence Intervals for Effect Sizes: Applying Bootstrap Resampling

    Science.gov (United States)

    Banjanovic, Erin S.; Osborne, Jason W.

    2016-01-01

    Confidence intervals for effect sizes (CIES) provide readers with an estimate of the strength of a reported statistic as well as the relative precision of the point estimate. These statistics offer more information and context than null hypothesis statistic testing. Although confidence intervals have been recommended by scholars for many years,…

  10. T(peak)T(end) interval in long QT syndrome

    DEFF Research Database (Denmark)

    Kanters, Jørgen Kim; Haarmark, Christian; Vedel-Larsen, Esben

    2008-01-01

    BACKGROUND: The T(peak)T(end) (T(p)T(e)) interval is believed to reflect the transmural dispersion of repolarization. Accordingly, it should be a risk factor in long QT syndrome (LQTS). The aim of the study was to determine the effect of genotype on T(p)T(e) interval and test whether it was related...

  11. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  12. Comparison of embrittlement trend curves to high fluence surveillance results

    International Nuclear Information System (INIS)

    Bogaert, A.S.; Gerard, R.; Chaouadi, R.

    2011-01-01

    In the regulatory justification of the integrity of the reactor pressure vessels (RPV) for long term operation, use is made of predictive formulas (also called trend curves) to evaluate the RPV embrittlement (expressed in terms of RTNDT shifts) in function of fluence, chemical composition and in some cases temperature, neutron flux or product form. It has been shown recently that some of the existing or proposed trend curves tend to underpredict high dose embrittlement. Due to the scarcity of representative surveillance data at high dose, some test reactor results were used in these evaluations and raise the issue of representativeness of the accelerated test reactor irradiations (dose rate effects). In Belgium the surveillance capsules withdrawal schedule was modified in the nineties in order to obtain results corresponding to 60 years of operation or more with the initial surveillance program. Some of these results are already available and offer a good opportunity to test the validity of the predictive formulas at high dose. In addition, advanced surveillance methods are used in Belgium like the Master Curve, increased tensile tests, and microstructural investigations. These techniques made it possible to show the conservatism of the regulatory approach and to demonstrate increased margins, especially for the first generation units. In this paper the surveillance results are compared to different predictive formulas, as well as to an engineering hardening model developed at SCK.CEN. Generally accepted property-to-property correlations are critically revisited. Conclusions are made on the reliability and applicability of the embrittlement trend curves. (authors)

  13. Privacy Implications of Surveillance Systems

    DEFF Research Database (Denmark)

    Thommesen, Jacob; Andersen, Henning Boje

    2009-01-01

    This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed for vari......This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed...... for various purposes, even as a service for those being observed, but in any case they will to some degree invade their privacy. The model provided here can indicate how invasive any particular system may be – and be used to compare the invasiveness of different systems. Applying a functional approach......, the model is established by first considering the social function of privacy in everyday life, which in turn lets us determine which different domains will be considered as private, and finally identify the different types of privacy invasion. This underlying model (function – domain – invasion) then serves...

  14. Closing the Gaps in Paediatric Reference Intervals: The CALIPER Initiative

    Science.gov (United States)

    Schnabl, Kareena; Chan, Man Khun; Gong, Yanping; Adeli, Khosrow

    2008-01-01

    Screening, diagnosis and monitoring of paediatric diseases relies on the measurement of a spectrum of disease biomarkers in clinical laboratories to guide important clinical decisions. Physicians rely on the availability of suitable and reliable reference intervals to accurately interpret laboratory test results with data collected during medical history and physical examination. However, critical gaps currently exist in accurate and up-to-date reference intervals (normal values) for accurate interpretation of laboratory tests performed in children and adolescents. These gaps in the available paediatric laboratory reference intervals have the clear potential of contributing to erroneous diagnosis or misdiagnosis of many diseases of childhood and adolescence. Most of the available reference intervals for laboratory tests were determined over two decades ago on older instruments and technologies, and are no longer relevant considering the current testing technology used by clinical laboratories. It is thus critical and of utmost urgency that a more acceptable and comprehensive database be established. There are however many challenges when attempting to establish paediatric reference intervals. Paediatric specimen collection is a major concern for health care providers as it is frequently difficult to obtain sufficient volumes of blood or urine from paediatric patients. Common reference intervals have not been widely implemented due to lack of harmonisation of methods and differences in patient populations. Consequently, clinical laboratory accreditation organisations and licensing agencies require that each laboratory verify or establish reference intervals for each method. To provide such reference intervals requires selection criteria for suitable reference individuals, defined conditions for specimen collection and analysis, method selection to determine reference limits and validation of the reference interval. The current review will provide a brief

  15. Feasibility and acceptability of workers' health surveillance for fire fighters

    NARCIS (Netherlands)

    Plat, Marie-Christine J.; Frings-Dresen, Monique H. W.; Sluiter, Judith K.

    2011-01-01

    The objective of this study was to test the feasibility and acceptability of a new workers' health surveillance (WHS) for fire fighters in a Dutch pilot-implementation project. In three fire departments, between November 2007 and February 2009, feasibility was tested with respect to i) worker intent

  16. Elementary Surveillance (ELS) and Enhanced Surveillance (EHS) Validation via Mode S Secondary Radar Surveillance

    National Research Council Canada - National Science Library

    Grappel, Robert D; Harris, Garrett S; Kozar, Mark J; Wiken, Randall T

    2008-01-01

    ...) and Enhanced Surveillance (ERS) data link applications. The intended audience for this report is an engineering staff assigned the task of implementing a monitoring system used to determine ELS and EHS compliance...

  17. Calibration interval technical basis document

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1998-09-01

    This document provides a method for the establishment and evaluation of calibration intervals for radiation protection instrumentation. This document is applicable to instrumentation used by personnel at US Department of Energy (DOE) facilities for the measurement of radioactive contamination and the measurement and monitoring of radiation fields for protection of personnel and the environment. Special calibrations are not addressed by this document and should be handled separately

  18. Serological surveillance of measles in blood donors in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Rosângela Castro-Silva

    2003-11-01

    Full Text Available OBJECTIVES: To estimate the proportion of individuals seronegative for measles antibody among blood donors from a blood bank in the city of Rio de Janeiro, Brazil, and to describe their social and demographic characteristics, with the goal of exploring the potential use of plasma banks to supplement serological surveillance with relevant data in order to support the program of measles elimination in the city of Rio de Janeiro and elsewhere. METHODS: Plasma samples from 1 101 consecutive blood donations made in November 2000 at HEMORIO, the largest blood bank in the state of Rio de Janeiro, were tested for measles immunoglobulin G, using a commercial enzyme immunoassay and a plaque reduction neutralization test. We calculated the proportion (and 95% confidence interval (CI of samples seronegative for measles antibody for the total sample of blood donors and also for subgroups categorized by age, sex, neighborhood of residence, education, and occupation. We used the chi-square test to assess the statistical significance of differences in proportions and linear trends in proportions. RESULTS: Of the total group of blood donors, 6.9% of them (95% CI: 5.4%­8.4% were seronegative for measles. Women had a higher proportion (10.1%; 95% CI: 6.8%­13.4% of seronegative results than did men (5.6%; 95% CI: 4.0%­7.2%. In terms of age, 86.8% of seronegative individuals were born between 1971 and 1982. Seronegativity was inversely proportional to age (chi-square = 58.0; P < 0.0001. With regard to occupation, students had the highest proportion of seronegative individuals (17.8%. In terms of education, most of the susceptible persons were in the categories of "incomplete university degree" or "incomplete high school." For the various areas of residence the proportions ranged from 2.1% to 11.4%. CONCLUSIONS: Blood bank plasma may constitute a useful and convenient source of complementary data for serological surveillance in adults of measles and other

  19. Low Rates of Retention Into Hepatocellular Carcinoma (HCC) Surveillance Program After Initial HCC Screening.

    Science.gov (United States)

    Robinson, Ann; Tavakoli, Hesam; Cheung, Ramsey; Liu, Benny; Bhuket, Taft; Wong, Robert J

    2018-04-06

    To evaluate rates and predictors of retention into hepatocellular carcinoma (HCC) surveillance beyond initial screening among underserved cirrhosis patients. Although initial HCC screening among cirrhosis patients remains low, few studies have evaluated retention to HCC surveillance beyond initial screening. We retrospectively evaluated all consecutive adults with cirrhosis from 2014 to 2017 at a single underserved safety net hospital system to determine rates of HCC surveillance at 6 months and at 1 year beyond initial screening. Rates of HCC surveillance was stratified by sex, race/ethnicity, and etiology of liver disease. Multivariate Cox proportional hazards models evaluated predictors of retention into HCC surveillance. Among 235 cirrhosis patients [hepatitis C virus: 35.7%, hepatitis B virus (HBV): 15.7%, alcoholic cirrhosis: 36.2%, nonalcoholic steatohepatitis (NASH): 8.1%], mean age of cirrhosis diagnosis was 54.2±8.9 years. Overall, 74.8% received initial screening within 1 year of cirrhosis diagnosis. Among those who completed initial screening, 47.6% [95% confidence interval (CI), 41.4-54.2) received second surveillance within 1 year. On multivariate analyses, patients with NASH and HBV were significantly more likely to receive second HCC surveillance compared with hepatitis C virus, HBV (hazard ratio, 2.32; 95% CI, 1.18-4.56; P=0.014) and NASH (hazard ratio, 2.49; 95% CI, 1.22-5.11; P=0.012). No sex or race-specific/ethnicity-specific differences in HCC surveillance retention were observed. Although overall rates of initial HCC screening among cirrhosis patients is nearly 75%, retention into continued HCC surveillance is poor, with less than half of patients undergoing subsequent HCC surveillance. Cirrhosis patients with HBV and NASH were more likely to be retained into HCC surveillance.

  20. Statistical intervals a guide for practitioners

    CERN Document Server

    Hahn, Gerald J

    2011-01-01

    Presents a detailed exposition of statistical intervals and emphasizes applications in industry. The discussion differentiates at an elementary level among different kinds of statistical intervals and gives instruction with numerous examples and simple math on how to construct such intervals from sample data. This includes confidence intervals to contain a population percentile, confidence intervals on probability of meeting specified threshold value, and prediction intervals to include observation in a future sample. Also has an appendix containing computer subroutines for nonparametric stati

  1. Simplified interval type-2 fuzzy neural networks.

    Science.gov (United States)

    Lin, Yang-Yin; Liao, Shih-Hui; Chang, Jyh-Yeong; Lin, Chin-Teng

    2014-05-01

    This paper describes a self-evolving interval type-2 fuzzy neural network (FNN) for various applications. As type-1 fuzzy systems cannot effectively handle uncertainties in information within the knowledge base, we propose a simple interval type-2 FNN, which uses interval type-2 fuzzy sets in the premise and the Takagi-Sugeno-Kang (TSK) type in the consequent of the fuzzy rule. The TSK-type consequent of fuzzy rule is a linear combination of exogenous input variables. Given an initially empty the rule-base, all rules are generated with on-line type-2 fuzzy clustering. Instead of the time-consuming K-M iterative procedure, the design factors ql and qr are learned to adaptively adjust the upper and lower positions on the left and right limit outputs, using the parameter update rule based on a gradient descent algorithm. Simulation results demonstrate that our approach yields fewer test errors and less computational complexity than other type-2 FNNs.

  2. Surveillance Camera Players / Bill Brown ; interv. Tilman Baumgärtel

    Index Scriptorium Estoniae

    Brown, Bill

    2006-01-01

    New Yorgis tegutsevast rühmitusest SCP (Turvakaamera Esinejad), mille rajas Bill Brown (sünd. 1959), temaga 2001. a. jaanuaris tehtud meiliintervjuu. SCP etendab näidendeid turvakaamerate ees, Internetis jagab informatsiooni oma tegevuse kohta. Tekstis: "...kuna SCP keskendub turvakaameratele, kasutades nende loogikat selle tehnoloogia enda vastu, siis võib öelda, et nad töötavad kommunikatsioonivõrkudega"

  3. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  4. Active surveillance for localized prostate cancer

    DEFF Research Database (Denmark)

    Thostrup, Mathias; Thomsen, Frederik B; Iversen, Peter

    2018-01-01

    OBJECTIVE: The purpose of active surveillance (AS) is to reduce overtreatment of men with localized prostate cancer (PCa) without compromising survival. The objective of this study was to update a large Scandinavian single-center AS cohort. Furthermore, the use of curative treatment and subsequent...... risk of biochemical recurrence were investigated and compared in men with very low-risk, low-risk and intermediate-risk PCa in the cohort. MATERIALS AND METHODS: In total, 451 men were followed on AS and monitored with prostate-specific antigen (PSA) tests, digital rectal examinations and rebiopsies...

  5. Project Surveillance and Maintenance Plan

    International Nuclear Information System (INIS)

    1985-09-01

    The Project Surveillance and Maintenance Plan (PSMP) describes the procedures that will be used by the US Department of Energy (DOE), or other agency as designated by the President to verify that inactive uranium tailings disposal facilities remain in compliance with licensing requirements and US Environmental Protection Agency (EPA) standards for remedial actions. The PSMP will be used as a guide for the development of individual Site Surveillance and Maintenance Plans (part of a license application) for each of the UMTRA Project sites. The PSMP is not intended to provide minimum requirements but rather to provide guidance in the selection of surveillance measures. For example, the plan acknowledges that ground-water monitoring may or may not be required and provides the [guidance] to make this decision. The Site Surveillance and Maintenance Plans (SSMPs) will form the basis for the licensing of the long-term surveillance and maintenance of each UMTRA Project site by the NRC. Therefore, the PSMP is a key milestone in the licensing process of all UMTRA Project sites. The Project Licensing Plan (DOE, 1984a) describes the licensing process. 11 refs., 22 figs., 8 tabs

  6. Variational collocation on finite intervals

    International Nuclear Information System (INIS)

    Amore, Paolo; Cervantes, Mayra; Fernandez, Francisco M

    2007-01-01

    In this paper, we study a set of functions, defined on an interval of finite width, which are orthogonal and which reduce to the sinc functions when the appropriate limit is taken. We show that these functions can be used within a variational approach to obtain accurate results for a variety of problems. We have applied them to the interpolation of functions on finite domains and to the solution of the Schroedinger equation, and we have compared the performance of the present approach with others

  7. Chaotic dynamics from interspike intervals

    DEFF Research Database (Denmark)

    Pavlov, A N; Sosnovtseva, Olga; Mosekilde, Erik

    2001-01-01

    Considering two different mathematical models describing chaotic spiking phenomena, namely, an integrate-and-fire and a threshold-crossing model, we discuss the problem of extracting dynamics from interspike intervals (ISIs) and show that the possibilities of computing the largest Lyapunov exponent...... (LE) from point processes differ between the two models. We also consider the problem of estimating the second LE and the possibility to diagnose hyperchaotic behavior by processing spike trains. Since the second exponent is quite sensitive to the structure of the ISI series, we investigate...

  8. Chaotic dynamics from interspike intervals

    DEFF Research Database (Denmark)

    Pavlov, A.N.; Sosnovtseva, Olga V.; Mosekilde, Erik

    2001-01-01

    Considering two different mathematical models describing chaotic spiking phenomena, namely, an integrate-and-fire and a threshold-crossing model, we discuss the problem of extracting dynamics from interspike intervals (ISIs) and show that the possibilities of computing the largest Lyapunov exponent...... (LE) from paint processes differ between the two models. We also consider the problem of estimating the second LE and the possibility to diagnose hyperchaotic behavior by processing spike trains. Since the second exponent is quite sensitive to the structure of the ISI series, we investigate...

  9. Dijets at large rapidity intervals

    CERN Document Server

    Pope, B G

    2001-01-01

    Inclusive diet production at large pseudorapidity intervals ( Delta eta ) between the two jets has been suggested as a regime for observing BFKL dynamics. We have measured the dijet cross section for large Delta eta in pp collisions at square root s = 1800 and 630 GeV using the DOE detector. The partonic cross section increases strongly with the size of Delta eta . The observed growth is even stronger than expected on the basis of BFKL resummation in the leading logarithmic approximation. The growth of the partonic cross section can be accommodated with an effective BFKL intercept of alpha /sub BFKL/(20 GeV) = 1.65 +or- 0.07.

  10. Haemostatic reference intervals in pregnancy

    DEFF Research Database (Denmark)

    Szecsi, Pal Bela; Jørgensen, Maja; Klajnbard, Anna

    2010-01-01

    , and protein C and in a subgroup of 186 women in addition for prothrombin time (PT), Owren and Quick PT, protein S activity, and total protein S and coagulation factors II, V, VII, VIII, IX, X, XI, and XII. The level of coagulation factors II, V, X, XI, XII and antithrombin, protein C, aPTT, PT remained...... largely unchanged during pregnancy, delivery, and postpartum and were within non-pregnant reference intervals. However, levels of fibrinogen, D-dimer, and coagulation factors VII, VIII, and IX increased markedly. Protein S activity decreased substantially, while free protein S decreased slightly and total...

  11. Present status of metrology of electro-optical surveillance systems

    Science.gov (United States)

    Chrzanowski, K.

    2017-10-01

    There has been a significant progress in equipment for testing electro-optical surveillance systems over the last decade. Modern test systems are increasingly computerized, employ advanced image processing and offer software support in measurement process. However, one great challenge, in form of relative low accuracy, still remains not solved. It is quite common that different test stations, when testing the same device, produce different results. It can even happen that two testing teams, while working on the same test station, with the same tested device, produce different results. Rapid growth of electro-optical technology, poor standardization, limited metrology infrastructure, subjective nature of some measurements, fundamental limitations from laws of physics, tendering rules and advances in artificial intelligence are major factors responsible for such situation. Regardless, next decade should bring significant improvements, since improvement in measurement accuracy is needed to sustain fast growth of electro-optical surveillance technology.

  12. Surveillance mission planning for UAVs in GPS-denied urban environment

    Science.gov (United States)

    Pengfei, Wang

    In this thesis, the issues involved in the mission planning of UAVs for city surveillance have been studied. In this thesis, the research includes two major parts. Firstly, a mission planning system is developed that generates mission plans for a group of fixed-wing UAVs with on-board gimballed cameras to provide continuous surveillance over an urban area. Secondly, the problem of perching location selection (as part of perch-and-stare surveillance mission) for rotary-wing UAVs in a GPS-denied environment is studied. In this kind of mission, a UAV is dispatched to perch on a roof of a building to keep surveillance on a given target. The proposed algorithms to UAV surveillance mission planning (fixed-wing and rotary-wing) have been implemented and tested. It represents an important step towards achieving autonomous planning in UAV surveillance missions.

  13. A Review of OIE Country Status Recovery Using Vaccinate-to-Live Versus Vaccinate-to-Die Foot-and-Mouth Disease Response Policies I: Benefits of Higher Potency Vaccines and Associated NSP DIVA Test Systems in Post-Outbreak Surveillance.

    Science.gov (United States)

    Barnett, P V; Geale, D W; Clarke, G; Davis, J; Kasari, T R

    2015-08-01

    To rapidly return to trade, countries with OIE status, FMD-free country where vaccination is not practised, have destroyed emergency vaccinated animals, raising ethical concerns with respect to social values, the environment, animal welfare and global food security. This two-part review explores whether science could support eligibility to return to previous OIE status in 3 months irrespective of vaccinate-to-live or vaccinate-to-die policies. Here, we examine the benefits of higher potency (≥ 6 PD50 ), high-purity vaccines formulated from antigen banks for emergency use, their efficacy and performance in differentiating infected from vaccinated animals (DIVA) assays for post-outbreak surveillance. From an intensive programme of research, we conclude that high-quality, higher potency vaccines are proven to reduce FMD virus (FMDV) subclinical circulation and the risk of carriers. Broader coverage than predicted by serology suggests the potential to hold a few 'key' vaccine strains improving logistics and reducing the financial burden of antigen banks. The OIE should adopt formal definitions for emergency vaccination and emergency vaccines. In terms of supportive tools, we consider that the lack of OIE recognition of DIVA tests other than those of PANAFTOSA in cattle is a shortcoming. There is need for research on maternal antibody interference with DIVA tests and on the use of such tests to establish whether greater purification of vaccines improves performance. We consider that alignment of waiting periods for vaccinate-to-live and vaccinate-to-die in OIE Code Article 8.5.9 1 b. and c. is feasible until an acceptable level of statistical certainty for surveillance or target probability of freedom is established to substantiate the absence of FMDV infection or circulation. It is surveillance intensity rather than waiting periods that establishes the risk of residual FMDV. EU Directive 2003/85/EC implicitly recognizes this, permitting derogation of the OIE waiting

  14. GEIS Surveillance Network Program

    Science.gov (United States)

    2013-10-01

    tafenoquine, dihydroartemisinin, Piperaquine, Mefloquine and doxycycline. Additional drugs were tested in the extended panel depending on the availability...lumefantrine (LU), atovaquone (AV), tafenoquine (TQ), dihydroartemisinin (DHA), Piperaquine (PPQ), Mefloquine (MQ) and doxycycline (DX). DHA and

  15. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  16. Informatics enables public health surveillance

    Directory of Open Access Journals (Sweden)

    Scott J. N McNabb

    2017-01-01

    Full Text Available Over the past decade, the world has radically changed. New advances in information and communication technologies (ICT connect the world in ways never imagined. Public health informatics (PHI leveraged for public health surveillance (PHS, can enable, enhance, and empower essential PHS functions (i.e., detection, reporting, confirmation, analyses, feedback, response. However, the tail doesn't wag the dog; as such, ICT cannot (should not drive public health surveillance strengthening. Rather, ICT can serve PHS to more effectively empower core functions. In this review, we explore promising ICT trends for prevention, detection, and response, laboratory reporting, push notification, analytics, predictive surveillance, and using new data sources, while recognizing that it is the people, politics, and policies that most challenge progress for implementation of solutions.

  17. Surveillance of avian influenza in the Caribbean through the Caribbean Animal Health Network: surveillance tools and epidemiologic studies.

    Science.gov (United States)

    Lefrançois, T; Hendrikx, P; Ehrhardt, N; Millien, M; Gomez, L; Gouyet, L; Gaidet, N; Gerbier, G; Vachiéry, N; Petitclerc, F; Carasco-Lacombe, C; Pinarello, V; Ahoussou, S; Levesque, A; Gongora, H V; Trotman, M

    2010-03-01

    The Caribbean region is considered to be at risk for avian influenza (AI) due to a large backyard poultry system, an important commercial poultry production system, the presence of migratory birds, and disparities in the surveillance systems. The Caribbean Animal Health Network (CaribVET) has developed tools to implement AI surveillance in the region with the goals to have 1) a regionally harmonized surveillance protocol and specific web pages for AI surveillance on www.caribvet.net, and 2) an active and passive surveillance for AI in domestic and wild birds. A diagnostic network for the Caribbean, including technology transfer and AI virus molecular diagnostic capability in Guadeloupe (real-time reverse transcription-polymerase chain reaction for the AI virus matrix gene), was developed. Between 2006 and 2009, 627 samples from four Caribbean countries were tested for three circumstances: importation purposes, following a clinical suspicion of AI, or through an active survey of wild birds (mainly waders) during the southward and northward migration periods in Guadeloupe. None of the samples tested were positive, suggesting a limited role of these species in the AI virus ecology in the Caribbean. Following low pathogenic H5N2 outbreaks in the Dominican Republic in 2007, a questionnaire was developed to collect data for a risk analysis of AI spread in the region through fighting cocks. The infection pathway of the Martinique commercial poultry sector by AI, through introduction of infected cocks, was designed, and recommendations were provided to the Caribbean Veterinary Services to improve cock movement control and biosecurity measures. The CaribVET and its organization allowed interaction between diagnostic and surveillance tools on the one hand and epidemiologic studies on the other, both of them developed in congruence with regional strategies. Together, these CaribVET activities contribute to strengthening surveillance of avian influenza virus (AIV) in the

  18. High Quality Camera Surveillance System

    OpenAIRE

    Helaakoski, Ari

    2015-01-01

    Oulu University of Applied Sciences Information Technology Author: Ari Helaakoski Title of the master’s thesis: High Quality Camera Surveillance System Supervisor: Kari Jyrkkä Term and year of completion: Spring 2015 Number of pages: 31 This master’s thesis was commissioned by iProtoXi Oy and it was done to one iProtoXi customer. The aim of the thesis was to make a camera surveillance system which is using a High Quality camera with pan and tilt possibility. It should b...

  19. Containment and Surveillance Equipment Compendium

    International Nuclear Information System (INIS)

    Luetters, F.O.

    1980-02-01

    The Containment and Surveillance Equipment Compendium contains information sections describing the application and status of seals, optical surveillance systems, and monitors for international safeguards systems. The Compendium is a collection of information on equipment in use (generally by the IAEA) or under development in the US in diverse programs being conducted at numerous facilities under different sponsors. The Compendium establishes a baseline for the status and applications of C/S equipment and is a tool to assist in the planning of future C/S hardware development activities. The Appendix contains design concepts which can be developed to meet future goals

  20. Burden of waiting for surveillance CT colonography in patients with screen-detected 6-9 mm polyps

    Energy Technology Data Exchange (ETDEWEB)

    Tutein Nolthenius, Charlotte J. [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Boellaard, Thierry N.; Nio, C.Y.; Bipat, Shandra; Stoker, Jaap [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Haan, Margriet C. de [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Thomeer, Maarten G.J. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Montauban van Swijndregt, Alexander D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Essink-Bot, Marie-Louise [University of Amsterdam, Public Health, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Kuipers, Ernst J. [Erasmus University Medical Center, Gastroenterology and Hepatology, Rotterdam (Netherlands); Erasmus University Medical Center, Internal medicine, Rotterdam (Netherlands); Dekker, Evelien [University of Amsterdam, Gastroenterology and Hepatology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands)

    2016-11-15

    We assessed the burden of waiting for surveillance CT colonography (CTC) performed in patients having 6-9 mm colorectal polyps on primary screening CTC. Additionally, we compared the burden of primary and surveillance CTC. In an invitational population-based CTC screening trial, 101 persons were diagnosed with <3 polyps 6-9 mm, for which surveillance CTC after 3 years was advised. Validated questionnaires regarding expected and perceived burden (5-point Likert scales) were completed before and after index and surveillance CTC, also including items on burden of waiting for surveillance CTC. McNemar's test was used for comparison after dichotomization. Seventy-eight (77 %) of 101 invitees underwent surveillance CTC, of which 66 (85 %) completed the expected and 62 (79 %) the perceived burden questionnaire. The majority of participants (73 %) reported the experience of waiting for surveillance CTC as 'never' or 'only sometimes' burdensome. There was almost no difference in expected and perceived burden between surveillance and index CTC. Waiting for the results after the procedure was significantly more burdensome for surveillance CTC than for index CTC (23 vs. 8 %; p = 0.012). Waiting for surveillance CTC after primary CTC screening caused little or no burden for surveillance participants. In general, the burden of surveillance and index CTC were comparable. (orig.)

  1. Some Characterizations of Convex Interval Games

    NARCIS (Netherlands)

    Brânzei, R.; Tijs, S.H.; Alparslan-Gok, S.Z.

    2008-01-01

    This paper focuses on new characterizations of convex interval games using the notions of exactness and superadditivity. We also relate big boss interval games with concave interval games and obtain characterizations of big boss interval games in terms of exactness and subadditivity.

  2. Combination of interval set and soft set

    Directory of Open Access Journals (Sweden)

    Keyun Qin

    2013-04-01

    Full Text Available Soft set theory and interval set theory are all mathematical tools for dealing with uncertainties. This paper is devoted to the discussion of soft interval set and its application. The notion of soft interval sets is introduced by combining soft set and interval set. Several operations on soft interval sets are presented in a manner parallel to that used in defining operations on soft sets and the lattice structures of soft interval sets are established. In addition, a soft interval set based decision making problem is analyzed.

  3. Severe combined immunodeficiency: a national surveillance study.

    Science.gov (United States)

    Yee, Anthony; De Ravin, Suk See; Elliott, Elizabeth; Ziegler, John B

    2008-06-01

    National immunodeficiency registers in several countries have reported prevalence but not incidence rates for severe combined immunodeficiency (SCID). The objective of this study was to document the incidence and type of SCID in Australia, the age and clinical features at presentation and short-term management. The Australian Paediatric Surveillance Unit conducts active, monthly, national surveillance of rare disorders with reporting by child-health specialists. Between May 1995 and December 2001, clinicians provided clinical and laboratory data on children newly diagnosed with SCID. Thirty-three incident cases of SCID were identified [incidence 1.8/10(5) live births per annum; 95% confidence interval (CI) 1.2-2.5]. Twenty-six children had classical SCID (1.45/10(5) live births; 95% CI, 0.9-2.0) and 20 (77%) of these were boys. Classical SCID was X-linked in 13 children, autosomal recessive (AR), not further classified in four, and attributed to adenosine deaminase deficiency (ADA) in four, interleukin-7 receptor alpha chain deficiency in one, Ommen syndrome in two, and Di George syndrome in two. Twenty-one (81%) received bone marrow/stem cell transplantation, three of whom died between 1 and 4 months after transplantation (two ADA deficient, one AR). Seven children had atypical SCID, five of whom died within 1-4 yr of diagnosis. Most children with SCID presented with failure to thrive and recurrent infections and there was no significant delay between presentation and diagnosis. The reported national incidence of classical SCID in Australia (1.45/10(5) or approximately 4 cases per year or 1/69,000 live births) is consistent with the rate (1.4/10(5)) previously reported in Victoria. Diagnosis is rarely delayed, and transplantation is associated with good short-term survival.

  4. BIOCHEMISTRY PANEL REFERENCE INTERVALS FOR JUVENILE GOLDFISH (CARASSIUS AURATUS).

    Science.gov (United States)

    Adamovicz, Laura A; Trosclair, Macy R; Lewbart, Gregory A

    2017-09-01

    Reference intervals for diagnostic tests are vitally important for clinical decision making. Despite the popularity of pet goldfish (Carassius auratus), reference intervals have not been generated for routine biochemistry panel analytes in this species. This study establishes de novo reference intervals for packed cell volume and total solids, using 47 apparently healthy immature goldfish, and for 11 common chemistry panel analytes (albumin, aspartate aminotransferase, calcium, creatine kinase, globulin, blood glucose, sodium, potassium, phosphorous, total protein, and uric acid) using 39 immature goldfish. Robust reference intervals were generated following recommendations of the American Society for Veterinary Clinical Pathology. Linear regression was used to demonstrate a statistically significant relationship between body weight and calcium, albumin, total protein, potassium, packed cell volume, and total solids. The results of this study serve as a useful baseline for future reference interval generation in goldfish.

  5. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  6. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  7. Inappropriate colonoscopic surveillance of hyperplastic polyps.

    LENUS (Irish Health Repository)

    Keane, R A

    2011-11-15

    Colonoscopic surveillance of hyperplastic polyps alone is controversial and may be inappropriate. The colonoscopy surveillance register at a university teaching hospital was audited to determine the extent of such hyperplastic polyp surveillance. The surveillance endoscopy records were reviewed, those patients with hyperplastic polyps were identified, their clinical records were examined and contact was made with each patient. Of the 483 patients undergoing surveillance for colonic polyps 113 (23%) had hyperplastic polyps alone on last colonoscopy. 104 patients remained after exclusion of those under appropriate surveillance. 87 of the 104 patients (84%) were successfully contacted. 37 patients (8%) were under appropriate colonoscopic surveillance for a significant family history of colorectal carcinoma. 50 (10%) patients with hyperplastic polyps alone and no other clinical indication for colonoscopic surveillance were booked for follow up colonoscopy. This represents not only a budgetary but more importantly a clinical opportunity cost the removal of which could liberate valuable colonoscopy time for more appropriate indications.

  8. Regional Disease Surveillance Meeting - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lesperance, Ann M.; Mahy, Heidi A.

    2006-08-08

    On June 1, 2006, public health officials working in surveillance, epidemiological modeling, and information technology communities from the Seattle/Tacoma area and State of Washington met with members of the Pacific Northwest National Laboratory (PNNL) to discuss the current state of disease surveillance and gaps and needs to improve the current systems. The meeting also included a discussion of PNNL initiatives that might be appropriate to enhance disease surveillance and the current tools being used for disease surveillance. Participants broke out into two groups to identify critical gaps and needs for improving a surveillance system, and discuss the requirements for developing improved surveillance. Each group developed a list of key priorities summarizing the requirements for improved surveillance. The objective of this meeting was to work towards the development of an improved disease surveillance system.

  9. Smart sensing surveillance video system

    Science.gov (United States)

    Hsu, Charles; Szu, Harold

    2016-05-01

    An intelligent video surveillance system is able to detect and identify abnormal and alarming situations by analyzing object movement. The Smart Sensing Surveillance Video (S3V) System is proposed to minimize video processing and transmission, thus allowing a fixed number of cameras to be connected on the system, and making it suitable for its applications in remote battlefield, tactical, and civilian applications including border surveillance, special force operations, airfield protection, perimeter and building protection, and etc. The S3V System would be more effective if equipped with visual understanding capabilities to detect, analyze, and recognize objects, track motions, and predict intentions. In addition, alarm detection is performed on the basis of parameters of the moving objects and their trajectories, and is performed using semantic reasoning and ontologies. The S3V System capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded environments. It would be directly applicable to solutions for emergency response personnel, law enforcement, and other homeland security missions, as well as in applications requiring the interoperation of sensor networks with handheld or body-worn interface devices.

  10. Birth defects surveillance·

    African Journals Online (AJOL)

    1989-07-01

    Jul 1, 1989 ... A pilot birth defects surveillance system was established in. 1982 as part of an epidemiological baseline study pertaining to potential changes in water quality in the Cape Peninsula. The methodology used for reporting birth defects for two information systems, one hospital-based and the other popu-.

  11. Surveillance by diagnostic microbiology laboratories

    African Journals Online (AJOL)

    account for almost threequarters of all Acinetobacter baumannii bloodstream infections, supporting the decision to include colistin or tobramycin as empirical treatment options for ICU patients with suspected Gramnegative sepsis. The dissemination and utilisation of surveillance data is crucial if they are to impact on patient ...

  12. Tower controller surveillance system parameters.

    Science.gov (United States)

    1972-03-01

    A brief study of airport ground traffic control surveillance parameters has been conducted. The study addressed the following questions by means of a set of simple experiments: (1) Can vehicle ID be displayed in a suitable format; (2) What size displ...

  13. Conceptualising the Surveillance of Teachers

    Science.gov (United States)

    Page, Damien

    2017-01-01

    Schools are risky places: the risk of a poor Ofsted report, the risk of sliding down league tables, the risk of teachers abusing children, the risk of teachers being falsely accused of abuse. As a result of risk anxiety and the ever-increasing sophistication of technology, the surveillance of teachers has proliferated, becoming a future-oriented…

  14. Conversion to use of digital chest images for surveillance of coal workers' pneumoconiosis (black lung).

    Science.gov (United States)

    Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward

    2009-01-01

    To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.

  15. Tales From the Unit Interval

    DEFF Research Database (Denmark)

    Nielsen, Thor Pajhede

    Testing the validity of Value-at-Risk (VaR) forecasts, or backtesting, is an integral part of modern market risk management and regulation. This is often done by applying independence and coverage tests developed in Christoffersen (1998) to so-called hit-sequences derived from VaR forecasts...... and realized losses. However, as pointed out in the literature, see Christoffersen and Pelletier (2004), these aforementioned tests suffer from low rejection frequencies, or (empirical) power when applied to hit-sequences derived from simulations matching empirical stylized characteristics of return data. One...... for a higher, or k’th, order dependence. We provide closed form expressions for the tests as well as asymptotic theory. Not only do the generalized tests have power against k’th order dependence by definition, but also included simulations indicate improved power performance when replicating the aforementioned...

  16. Laboratory surveillance of Shigella dysenteriae type 1 in Kwazulu ...

    African Journals Online (AJOL)

    Objective. To collect data on the antimicrobial susceptibility of Shigella dysenteriae type 1 in KwaZulu-Natal, including the testing of newer therapeutic agents, and to evaluate the ability of laboratories to participate in a provincial surveillance programme. Design. Prospective descriptive study. Setting. Hospital laboratories in ...

  17. Oak Ridge Research reactor shutdown maintenance and surveillance

    International Nuclear Information System (INIS)

    Coleman, G.H.; Laughlin, D.L.

    1991-05-01

    The Department of Energy ordered the Oak Ridge Research Reactor to be placed in permanent shutdown on July 14, 1987. The paper outlines routine maintenance activities and surveillance tests performed April through September, 1990, on the reactor instrumentation and controls, process system, and the gaseous waste filter system. Preparations are being made to transfer the facility to the Remedial Action Program. 6 tabs

  18. Approaches to canine health surveillance.

    Science.gov (United States)

    O'Neill, Dan G; Church, David B; McGreevy, Paul D; Thomson, Peter C; Brodbelt, Dave C

    2014-01-01

    Effective canine health surveillance systems can be used to monitor disease in the general population, prioritise disorders for strategic control and focus clinical research, and to evaluate the success of these measures. The key attributes for optimal data collection systems that support canine disease surveillance are representativeness of the general population, validity of disorder data and sustainability. Limitations in these areas present as selection bias, misclassification bias and discontinuation of the system respectively. Canine health data sources are reviewed to identify their strengths and weaknesses for supporting effective canine health surveillance. Insurance data benefit from large and well-defined denominator populations but are limited by selection bias relating to the clinical events claimed and animals covered. Veterinary referral clinical data offer good reliability for diagnoses but are limited by referral bias for the disorders and animals included. Primary-care practice data have the advantage of excellent representation of the general dog population and recording at the point of care by veterinary professionals but may encounter misclassification problems and technical difficulties related to management and analysis of large datasets. Questionnaire surveys offer speed and low cost but may suffer from low response rates, poor data validation, recall bias and ill-defined denominator population information. Canine health scheme data benefit from well-characterised disorder and animal data but reflect selection bias during the voluntary submissions process. Formal UK passive surveillance systems are limited by chronic under-reporting and selection bias. It is concluded that active collection systems using secondary health data provide the optimal resource for canine health surveillance.

  19. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  20. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  1. Adherence to surveillance guidelines after removal of colorectal adenomas : a large, community-based study

    NARCIS (Netherlands)

    van Heijningen, Else-Mariette B.; Lansdorp-Vogelaar, Iris; Steyerberg, Ewout W.; Goede, S. Lucas; Dekker, Evelien; Lesterhuis, Wilco; ter Borg, Frank; Vecht, Juda; Spoelstra, Pieter; Engels, Leopold; Bolwerk, Clemens J. M.; Timmer, Robin; Kleibeuker, Jan H.; Koornstra, Jan J.; de Koning, Harry J.; Kuipers, Ernst J.; van Ballegooijen, Marjolein

    2015-01-01

    Objective To determine adherence to recommended surveillance intervals in clinical practice. Design 2997 successive patients with a first adenoma diagnosis (57% male, mean age 59 years) from 10 hospitals, who underwent colonoscopy between 1998 and 2002, were identified via Pathologisch Anatomisch

  2. Colonoscopy surveillance for dysplasia and colorectal cancer in patients with inflammatory bowel disease

    DEFF Research Database (Denmark)

    Aalykke, Claus; Jensen, Michael Dam; Fallingborg, Jan

    2015-01-01

    colitis; and patients with ulcerative colitis as well as Crohn´s disease with a concomitant diagnosis of primary sclerosing cholangitis. A colonoscopy surveillance program is recommended in these subgroups with intervals ranging from every 3-6 months to every 5 years, using chromoendoscopy with targeted...

  3. 40 CFR 52.12 - Source surveillance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Source surveillance. 52.12 Section 52...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.12 Source surveillance. (a) Each subpart identifies the plan provisions for source surveillance which are disapproved, and sets forth the...

  4. 10 CFR 34.51 - Surveillance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Surveillance. 34.51 Section 34.51 Energy NUCLEAR... RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.51 Surveillance. During each radiographic operation... direct visual surveillance of the operation to protect against unauthorized entry into a high radiation...

  5. 48 CFR 44.304 - Surveillance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Surveillance. 44.304... SUBCONTRACTING POLICIES AND PROCEDURES Contractors' Purchasing Systems Reviews 44.304 Surveillance. (a) The ACO shall maintain a sufficient level of surveillance to ensure that the contractor is effectively managing...

  6. 10 CFR 850.34 - Medical surveillance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Medical surveillance. 850.34 Section 850.34 Energy... Medical surveillance. (a) General. (1) The responsible employer must establish and implement a medical surveillance program for beryllium-associated workers who voluntarily participate in the program. (2) The...

  7. 49 CFR 192.613 - Continuing surveillance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Continuing surveillance. 192.613 Section 192.613... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Operations § 192.613 Continuing surveillance. (a) Each operator shall have a procedure for continuing surveillance of its facilities to determine and take...

  8. LWR-PV Surveillance Dosimetry Improvement Program review graphics

    International Nuclear Information System (INIS)

    McElroy, W.N.; Gold, R.; Gutherie, G.L.

    1979-10-01

    A primary objective of the multilaboratory program is to prepare an updated and improved set of dosimetry, damage correlation, and the associated reactor analysis ASTM standards for LWR-PV irradiation surveillance programs. Supporting this objective are a series of analytical and experimental validation and calibration studies in Benchmark Neutron Fields, reactor Test Regions, and operating power reactor Surveillance Positions. These studies will establish and certify the precision and accuracy of the measurement and predictive methods which are recommended for use in these standards. Consistent and accurate measurement and data analysis techniques and methods, therefore, will have been developed and validated along with guidelines for required neutron field calculations that are used to (1) correlate changes in material properties with the characteristics of the neutron radiation field and (2) predict pressure vessel steel toughness and embrittlement from power reactor surveillance data

  9. Evaluation of risk impact of changes to surveillance requirements addressing model and parameter uncertainties

    International Nuclear Information System (INIS)

    Martorell, S.; Villamizar, M.; Martón, I.; Villanueva, J.F.; Carlos, S.; Sánchez, A.I.

    2014-01-01

    This paper presents a three steps based approach for the evaluation of risk impact of changes to Surveillance Requirements based on the use of the Probabilistic Risk Assessment and addressing identification, treatment and analysis of model and parameter uncertainties in an integrated manner. The paper includes also an example of application that focuses on the evaluation of the risk impact of a Surveillance Frequency change for the Reactor Protection System of a Nuclear Power Plant using a level 1 Probabilistic Risk Assessment. Surveillance Requirements are part of Technical Specifications that are included into the Licensing Basis for operation of Nuclear Power Plants. Surveillance Requirements aim at limiting risk of undetected downtimes of safety related equipment by imposing equipment operability checks, which consist of testing of equipment operational parameters with established Surveillance Frequency and Test Strategy

  10. Clinical laboratory reference intervals in pediatrics: the CALIPER initiative.

    Science.gov (United States)

    Jung, Benjamin; Adeli, Khosrow

    2009-11-01

    Reference intervals provided on laboratory reports are essential for appropriate interpretation of test results, and can significantly impact clinical decision-making and the quality of patient care. Careful determination and/or validation of reference intervals by the laboratory for use in the patient population it serves are therefore important to ensure their proper utility. Unfortunately, critical gaps currently exist in accurate and up-to-date pediatric reference intervals for accurate interpretation of laboratory tests performed in children and adolescents. These critical gaps in the available pediatric laboratory reference intervals have the clear potential of contributing to erroneous diagnosis or misdiagnosis of many diseases of childhood and adolescence. Most of the available "normal" ranges for laboratory tests were determined over 2 decades ago on older instruments and technologies, and are no longer relevant considering the current testing technology used by clinical laboratories. It is thus critical and of utmost urgency that a more acceptable and comprehensive database be established. In the present review, we discuss the considerations and challenges faced when generating and validating reference intervals in accordance to the current guidelines published by the Clinical Laboratory Standards Institute (CLSI). We raise particular attention to the present-day deficiencies in available pediatric reference intervals, and highlight the special issues and unique difficulties that are additionally faced when establishing reference intervals in children. Finally, we highlight a recent Canadian initiative, the CALIPER project, whose mandate is to establish and maintain a database of comprehensive and up-to-date pediatric reference intervals to be eventually made available to all clinical laboratories worldwide.

  11. GHOST: global hepatitis outbreak and surveillance technology.

    Science.gov (United States)

    Longmire, Atkinson G; Sims, Seth; Rytsareva, Inna; Campo, David S; Skums, Pavel; Dimitrova, Zoya; Ramachandran, Sumathi; Medrzycki, Magdalena; Thai, Hong; Ganova-Raeva, Lilia; Lin, Yulin; Punkova, Lili T; Sue, Amanda; Mirabito, Massimo; Wang, Silver; Tracy, Robin; Bolet, Victor; Sukalac, Thom; Lynberg, Chris; Khudyakov, Yury

    2017-12-06

    Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics

  12. Mnemonic benefits of retrieval practice at short retention intervals.

    Science.gov (United States)

    Rowland, Christopher A; DeLosh, Edward L

    2015-01-01

    The testing effect refers to the retention benefit conferred by prior retrieval of information from memory. Although the testing effect is a robust phenomenon, a common assumption is that reliable memory benefits only emerge after long retention intervals of days or weeks. The present study focused on potential test-induced retention benefits for brief retention intervals on the order of minutes and tens of seconds. Participants in four experiments studied lists of words. Some of the items were subjected to an initial cued recall test, and others were re-presented for additional study. Free recall tests were administered in each experiment following retention intervals ranging from 30 s to 8 min. When initial retrieval practice was successful (Experiments 1 through 3), or feedback compensated for unsuccessful retrieval (Experiment 4), significant testing effects emerged at all retention intervals. Results are discussed in the context of a bifurcated item-distribution model and highlight the importance of initial test performance and the type of analysis employed when examining testing effect data.

  13. Using the confidence interval confidently.

    Science.gov (United States)

    Hazra, Avijit

    2017-10-01

    Biomedical research is seldom done with entire populations but rather with samples drawn from a population. Although we work with samples, our goal is to describe and draw inferences regarding the underlying population. It is possible to use a sample statistic and estimates of error in the sample to get a fair idea of the population parameter, not as a single value, but as a range of values. This range is the confidence interval (CI) which is estimated on the basis of a desired confidence level. Calculation of the CI of a sample statistic takes the general form: CI = Point estimate ± Margin of error, where the margin of error is given by the product of a critical value (z) derived from the standard normal curve and the standard error of point estimate. Calculation of the standard error varies depending on whether the sample statistic of interest is a mean, proportion, odds ratio (OR), and so on. The factors affecting the width of the CI include the desired confidence level, the sample size and the variability in the sample. Although the 95% CI is most often used in biomedical research, a CI can be calculated for any level of confidence. A 99% CI will be wider than 95% CI for the same sample. Conflict between clinical importance and statistical significance is an important issue in biomedical research. Clinical importance is best inferred by looking at the effect size, that is how much is the actual change or difference. However, statistical significance in terms of P only suggests whether there is any difference in probability terms. Use of the CI supplements the P value by providing an estimate of actual clinical effect. Of late, clinical trials are being designed specifically as superiority, non-inferiority or equivalence studies. The conclusions from these alternative trial designs are based on CI values rather than the P value from intergroup comparison.

  14. Monitors for the surveillance of NPP components

    International Nuclear Information System (INIS)

    Giera, H.D.; Grabner, A.; Hessel, G.; Koeppen, H.E.; Liewers, P.; Schumann, P.; Weiss, F.P.; Kunze, U.; Pfeiffer, G.

    1985-01-01

    Noise diagnostics have reached a level where it is possible and efficient to integrate this method as far as possible into the control and safety system of the NPP. The communication between the noise diagnostic system and the plant operator is the main problem of integration. It is necessary to refine the diagnostic results in such a manner that the operator can use them without being skilled in noise analysis respectively without contacting a noise specialist. Moreover, in this way the noise specialist can be released from routine surveillance. For selected processes which have already intensively been investigated because of their inherent risk this can be achieved by means of autonomously working monitors. Independently the monitors perform signal processing and diagnosis. In general this means that they classify the technical condition of the monitored component into one of the two categories: ''normal'' or ''anomalous''. The result will be annunciated to the plant operator who will in the first step of the development contact the noise specialist only if anomalies have occurred in order to clarify the cause. At the NPP ''Bruno Leuschner'' Greifswald, three hardware monitors for loose parts detection, control rod surveillance and main coolant pump diagnosis are being tested. Additionally a so-called software monitor for diagnosing the pressure vessel vibrations is in preparation. The techniques and the hardware used for the monitors as well as planned further improvements of the integration of noise diagnostics into the control and safety system are discussed in this paper. (author)

  15. Continuous sequential boundaries for vaccine safety surveillance.

    Science.gov (United States)

    Li, Rongxia; Stewart, Brock; Weintraub, Eric; McNeil, Michael M

    2014-08-30

    Various recently developed sequential methods have been used to detect signals for post-marketing surveillance in drug and vaccine safety. Among these, the maximized sequential probability ratio test (MaxSPRT) has been used to detect elevated risks of adverse events following vaccination using large healthcare databases. However, a limitation of MaxSPRT is that it only provides a time-invariant flat boundary. In this study, we propose the use of time-varying boundaries for controlling how type I error is distributed throughout the surveillance period. This is especially useful in two scenarios: (i) when we desire generally larger sample sizes before a signal is generated, for example, when early adopters are not representative of the larger population; and (ii) when it is desired for a signal to be generated as early as possible, for example, when the adverse event is considered rare but serious. We consider four specific time-varying boundaries (which we call critical value functions), and we study their statistical power and average time to signal detection. The methodology we present here can be viewed as a generalization or flexible extension of MaxSPRT. Published 2014. This article is a US Government work and is in the public domain in the USA.

  16. Pigeons' Choices between Fixed-Interval and Random-Interval Schedules: Utility of Variability?

    Science.gov (United States)

    Andrzejewski, Matthew E.; Cardinal, Claudia D.; Field, Douglas P.; Flannery, Barbara A.; Johnson, Michael; Bailey, Kathleen; Hineline, Philip N.

    2005-01-01

    Pigeons' choosing between fixed-interval and random-interval schedules of reinforcement was investigated in three experiments using a discrete-trial procedure. In all three experiments, the random-interval schedule was generated by sampling a probability distribution at an interval (and in multiples of the interval) equal to that of the…

  17. A note on birth interval distributions

    International Nuclear Information System (INIS)

    Shrestha, G.

    1989-08-01

    A considerable amount of work has been done regarding the birth interval analysis in mathematical demography. This paper is prepared with the intention of reviewing some probability models related to interlive birth intervals proposed by different researchers. (author). 14 refs

  18. Confidence Intervals for Weighted Composite Scores under the Compound Binomial Error Model

    Science.gov (United States)

    Kim, Kyung Yong; Lee, Won-Chan

    2018-01-01

    Reporting confidence intervals with test scores helps test users make important decisions about examinees by providing information about the precision of test scores. Although a variety of estimation procedures based on the binomial error model are available for computing intervals for test scores, these procedures assume that items are randomly…

  19. P values and confidence intervals are reported in almost all scientific ...

    African Journals Online (AJOL)

    and there are no significant results. This article describes some facts about the p value and confidence intervals. The reporting of p values and confidence intervals usually follows hypothesis testing or significance testing. Most scientific investigations involve the testing of hypotheses. These are formal procedures for testing.

  20. Video Surveillance: Privacy Issues and Legal Compliance

    DEFF Research Database (Denmark)

    Mahmood Rajpoot, Qasim; Jensen, Christian D.

    2015-01-01

    Pervasive usage of video surveillance is rapidly increasing in developed countries. Continuous security threats to public safety demand use of such systems. Contemporary video surveillance systems offer advanced functionalities which threaten the privacy of those recorded in the video. There is a......Pervasive usage of video surveillance is rapidly increasing in developed countries. Continuous security threats to public safety demand use of such systems. Contemporary video surveillance systems offer advanced functionalities which threaten the privacy of those recorded in the video....... There is a need to balance the usage of video surveillance against its negative impact on privacy. This chapter aims to highlight the privacy issues in video surveillance and provides a model to help identify the privacy requirements in a video surveillance system. The authors make a step in the direction...

  1. Negotiating privacy in surveillant welfare relations

    DEFF Research Database (Denmark)

    Andersen, Lars Bo; Lauritsen, Peter; Bøge, Ask Risom

    The Danish welfare system is dependent on surveillance practices. Health authorities screen for diseases, tax authorities surveil financial flows, and social services are surveillant to vulnerable families. Such state surveillance is often related to, and opposed to, the privacy of citizens....... However, while privacy is central to debates of surveillance, it has proven less productive as an analytical resource for studying surveillance in practice. Consequently, this paper reviews different conceptualisations of privacy in relation to welfare and surveillance and argues for strengthening...... the analytical capacity of the concept by rendering it a situated and relational concept. The argument is developed through a research and design project called Teledialogue meant to improve the relation between case managers and children placed at institutions or in foster families. Privacy in Teledialogue...

  2. Public involvement in environmental surveillance at Hanford

    International Nuclear Information System (INIS)

    Hanf, R.W. Jr.; Patton, G.W.; Woodruff, R.K.; Poston, T.M.

    1994-08-01

    Environmental surveillance at the Hanford Site began during the mid-1940s following the construction and start-up of the nation's first plutonium production reactor. Over the past approximately 45 years, surveillance operations on and off the Site have continued, with virtually all sampling being conducted by Hanford Site workers. Recently, the US Department of Energy Richland Operations Office directed that public involvement in Hanford environmental surveillance operations be initiated. Accordingly, three special radiological air monitoring stations were constructed offsite, near hanford's perimeter. Each station is managed and operated by two local school teaches. These three stations are the beginning of a community-operated environmental surveillance program that will ultimately involve the public in most surveillance operations around the Site. The program was designed to stimulate interest in Hanford environmental surveillance operations, and to help the public better understand surveillance results. The program has also been used to enhance educational opportunities at local schools

  3. Risk based surveillance for vector borne diseases

    DEFF Research Database (Denmark)

    Bødker, Rene

    of samples and hence early detection of outbreaks. Models for vector borne diseases in Denmark have demonstrated dramatic variation in outbreak risk during the season and between years. The Danish VetMap project aims to make these risk based surveillance estimates available on the veterinarians smart phones...... in Northern Europe. This model approach may be used as a basis for risk based surveillance. In risk based surveillance limited resources for surveillance are targeted at geographical areas most at risk and only when the risk is high. This makes risk based surveillance a cost effective alternative...... sample to a diagnostic laboratory. Risk based surveillance models may reduce this delay. An important feature of risk based surveillance models is their ability to continuously communicate the level of risk to veterinarians and hence increase awareness when risk is high. This is essential for submission...

  4. 3013/9975 Surveillance Program Interim Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, K.; Hackney, B.; McClard, J.

    2011-06-22

    The K-Area Materials Storage (KAMS) Documented Safety Analysis (DSA) requires a surveillance program to monitor the safety performance of 3013 containers and 9975 shipping packages stored in KAMS. The SRS surveillance program [Reference 1] outlines activities for field surveillance and laboratory tests that demonstrate the packages meet the functional performance requirements described in the DSA. The SRS program also supports the complexwide Integrated Surveillance Program (ISP) [Reference 2] for 3013 containers. The purpose of this report is to provide a summary of the SRS portion of the surveillance program activities through fiscal year 2010 (FY10) and formally communicate the interpretation of these results by the Surveillance Program Authority (SPA). Surveillance for the initial 3013 container random sampling of the Innocuous bin and the Pressure bin has been completed and there has been no indication of corrosion or significant pressurization. The maximum pressure observed was less than 50 psig, which is well below the design pressure of 699 psig for the 3013 container [Reference 3]. The data collected during surveillance of these bins has been evaluated by the Materials Identification and Surveillance (MIS) Working Group and no additional surveillance is necessary for these bins at least through FY13. A decision will be made whether additional surveillance of these bins is needed during future years of storage and as additional containers are generated. Based on the data collected to date, the SPA concludes that 3013 containers in these bins can continue to be safely stored in KAMS. This year, 13 destructive examinations (DE) were performed on random samples from the Pressure & Corrosion bin. To date, DE has been completed for approximately 30% of the random samples from the Pressure & Corrosion bin. In addition, DE has been performed on 6 engineering judgment (EJ) containers, for a total of 17 to date. This includes one container that exceeded the 3013

  5. Health effects and medical surveillance

    International Nuclear Information System (INIS)

    1998-01-01

    Source of ionizing radiations have innumerable applications in the work place. Usually, even where the work is performed safely, the employees involved inevitably receive small, regular exposures to radiation that are not manifestly harmful. This Module explains how ionizing radiations can interact with and affect human tissues, the various factors that influence the outcome and the detrimental effects that may result. The medical surveillance that is appropriate for those working with radiation sources, depending on the degree of hazard of the work, is described. The Manual will be of most benefit it if forms part of more comprehensive training or is supplemented by the advice of a medically qualified expert. Where medical surveillance is appropriate for radiation employees, the services of a qualified doctor, occupational physician or other trained medical staff will be required

  6. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington

  7. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Zalesky, K.; Svarny, J.; Novak, L.; Rosol, J.; Horanes, A.

    1997-01-01

    The Halden Project has developed the core surveillance system SCORPIO which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. So far the system has only been implemented on western PWRs but the basic concept is applicable to a wide range of reactor including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO was initiated in cooperation with the Nuclear Research Institute at Rez and industry partners in the Czech Republic. The first system will be installed at the Dukovany NPP. (author)

  8. Mining Surveillance and Maintenance Dollars

    International Nuclear Information System (INIS)

    MARTINEZ, R.

    2000-01-01

    Accelerating site cleanup to reduce facility risks to the workers, the public and the environment during a time of declining federal budgets represents a significant technical and economic challenge to U.S. Department of Energy (DOE) Operations Offices and their respective contractors. A significant portion of a facility's recurring annual expenses are associated with routine, long-term surveillance and maintenance (S and M) activities. However, ongoing S and M activities do nothing to reduce risks and basically spend money that could be reallocated towards facility deactivation. This paper discusses the background around DOE efforts to reduce surveillance and maintenance costs, one approach used to perform cost reviews, lessons learned from field implementation and what assistance is available to assist DOE sites in performing these evaluations

  9. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  10. Performance indicators for rinderpest surveillance

    International Nuclear Information System (INIS)

    2001-12-01

    In 1986, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture initiated a programme of assistance to FAO and IAEA Member States for the development of effective, quality assured veterinary laboratory diagnostic services. This programme introduced the use of standardized and internationally validated ELISA-based systems for the diagnosis and surveillance of the major transboundary diseases that affect livestock. This approach has proved of immense value in the monitoring of national, regional and global animal disease control and eradication programmes. One such programme focuses on the global elimination of rinderpest. Co-ordinated by FAO through the Global Rinderpest Eradication Programme (GREP) the joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture has developed critical diagnostic and epidemiological tools to assist this effort. As the final stages of the global eradication of rinderpest are reached, it is fitting that the Joint Division should again take the lead in providing guidance to Member States on how best to meet the criteria for quality assurance of national disease surveillance programmes - a prerequisite for international acceptance of freedom from a particular disease. This publication is intended to provide countries involved in rinderpest eradication with a detailed protocol for using performance indicators in evaluating their disease surveillance system and making, where necessary, adjustments to meet the criteria for acceptance specified in the OIE Rinderpest Pathway - a pathway that leads to international recognition of freedom from rinderpest. An initial publication (IAEA-TECDOC-1161) described guidelines for the use of performance indicators in rinderpest surveillance programmes. This publication now describes in detail the protocols and the linked indicators which have been developed and field validated through a series of FAO/IAEA meetings and through IAEA expert assignments to countries in Africa

  11. An Adequate First Order Logic of Intervals

    DEFF Research Database (Denmark)

    Chaochen, Zhou; Hansen, Michael Reichhardt

    1998-01-01

    This paper introduces left and right neighbourhoods as primitive interval modalities to define other unary and binary modalities of intervals in a first order logic with interval length. A complete first order logic for the neighbourhood modalities is presented. It is demonstrated how the logic can...... support formal specification and verification of liveness and fairness, and also of various notions of real analysis....

  12. Skew products of interval maps over subshifts

    NARCIS (Netherlands)

    Gharaei, Masoumeh; Homburg, Ale Jan

    2016-01-01

    We treat step skew products over transitive subshifts of finite type with interval fibers. The fiber maps are diffeomorphisms on the interval; we assume that the end points of the interval are fixed under the fiber maps. Our paper thus extends work by V. Kleptsyn and D. Volk who treated step skew

  13. Consistency and Refinement for Interval Markov Chains

    DEFF Research Database (Denmark)

    Delahaye, Benoit; Larsen, Kim Guldstrand; Legay, Axel

    2012-01-01

    Interval Markov Chains (IMC), or Markov Chains with probability intervals in the transition matrix, are the base of a classic specification theory for probabilistic systems [18]. The standard semantics of IMCs assigns to a specification the set of all Markov Chains that satisfy its interval...

  14. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  15. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  16. Change in Breast Cancer Screening Intervals Since the 2009 USPSTF Guideline.

    Science.gov (United States)

    Wernli, Karen J; Arao, Robert F; Hubbard, Rebecca A; Sprague, Brian L; Alford-Teaster, Jennifer; Haas, Jennifer S; Henderson, Louise; Hill, Deidre; Lee, Christoph I; Tosteson, Anna N A; Onega, Tracy

    2017-08-01

    In 2009, the U.S. Preventive Services Task Force (USPSTF) recommended biennial mammography for women aged 50-74 years and shared decision-making for women aged 40-49 years for breast cancer screening. We evaluated changes in mammography screening interval after the 2009 recommendations. We conducted a prospective cohort study of women aged 40-74 years who received 821,052 screening mammograms between 2006 and 2012 using data from the Breast Cancer Surveillance Consortium. We compared changes in screening intervals and stratified intervals based on whether the mammogram at the end of the interval occurred before or after the 2009 recommendation. Differences in mean interval length by woman-level characteristics were compared using linear regression. The mean interval (in months) minimally decreased after the 2009 USPSTF recommendations. Among women aged 40-49 years, the mean interval decreased from 17.2 months to 17.1 months (difference -0.16%, 95% confidence interval [CI] -0.30 to -0.01). Similar small reductions were seen for most age groups. The largest change in interval length in the post-USPSTF period was declines among women with a first-degree family history of breast cancer (difference -0.68%, 95% CI -0.82 to -0.54) or a 5-year breast cancer risk ≥2.5% (difference -0.58%, 95% CI -0.73 to -0.44). The 2009 USPSTF recommendation did not lengthen the average mammography interval among women routinely participating in mammography screening. Future studies should evaluate whether breast cancer screening intervals lengthen toward biennial intervals following new national 2016 breast cancer screening recommendations, particularly among women less than 50 years of age.

  17. Hematological Reference Intervals for Healthy Iranian Blood Donors.

    Science.gov (United States)

    Rasouli, Mahboubeh; Pourmokhtar, Mojgan; Sarkardeh, Shaghayegh

    2017-10-01

    Background: Development of locally-derived hematological reference intervals is necessary for improving the quality of health care and clinical trials. However hematological reference intervals are affected by several variables including age, gender and environmental factors. Therefore this study was conducted to determine the gender and age-specific hematological reference intervals of healthy Iranian blood donors. Materials and Methods: Selected hematological indices of 394 healthy blood donor volunteers, donating blood at Tehran Blood Transfusion Center were analyzed. Hematological reference intervals, stratified by age and gender were compared. The results of current study were also compared with those of US population. Results: There were significant gender-related differences for mean values of hematological indices, with males having higher mean values of RBC, HCG, HCT and MCV than females. While the mean of PLT and MCH were higher in women. Age-related differences for mean values of RBC and MCH were also significant. The comparison of reference intervals, stratified by both gender and age showed that RBC, HGB and HCT values were higher in males than females in all age groups. But MCH values of females in all age groups and WBC and PLT counts in females older than 30 years were higher compared to the males in the same age group. The results of this study showed some similarity with US population, with narrower intervals. Conclusion: This study suggests that gender and age-specific, locally derived hematological reference intervals should be referred to, before interpretation of any laboratory test result.

  18. Studies and research concerning BNFP: process monitoring and process surveillance demonstration program

    Energy Technology Data Exchange (ETDEWEB)

    Kight, H R

    1979-11-01

    Computerized methods of monitoring process functions and alarming off-standard conditions were implemented and demonstrated during the FY 1979 Uranium Run. In addition, prototype applications of instruments for the purpose of tamper indication and surveillance were tested.

  19. Attaching Hollywood to a Surveillant Assemblage: Normalizing Discourses of Video Surveillance

    Directory of Open Access Journals (Sweden)

    Randy K Lippert

    2015-10-01

    Full Text Available This article examines video surveillance images in Hollywood film. It moves beyond previous accounts of video surveillance in relation to film by theoretically situating the use of these surveillance images in a broader “surveillant assemblage”. To this end, scenes from a sample of thirty-five (35 films of several genres are examined to discern dominant discourses and how they lend themselves to normalization of video surveillance. Four discourses are discovered and elaborated by providing examples from Hollywood films. While the films provide video surveillance with a positive associative association it is not without nuance and limitations. Thus, it is found that some forms of resistance to video surveillance are shown while its deterrent effect is not. It is ultimately argued that Hollywood film is becoming attached to a video surveillant assemblage discursively through these normalizing discourses as well as structurally to the extent actual video surveillance technology to produce the images is used.

  20. Impact of Bowel Preparation Quality on Adenoma Identification During Colonoscopy and Optimal Timing of Surveillance.

    Science.gov (United States)

    Kim, Ju Seok; Kang, Sun Hyung; Moon, Hee Seok; Lee, Eaum Seok; Kim, Seok Hyun; Sung, Jae Kyu; Lee, Byung Seok; Jeong, Hyun Yong; Chung, Woo Suk

    2015-10-01

    All present guidelines regarding surveillance intervals after index colonoscopy are based on optimal bowel preparation. However, the appropriate timing of repeat colonoscopy after suboptimal bowel preparation is not clear. To determine the appropriate timing of repeat colonoscopy following index colonoscopy with suboptimal bowel preparation. The medical records of patients who underwent colonoscopy over 5 years were retrospectively analyzed. Index colonoscopy was defined as the first colonoscopy in patients who underwent the procedure at least twice during the study period. Bowel preparation quality was classified as optimal, fair, or poor. The overall adenoma detection rate was 39.1% (95% confidence interval [CI], 38.0-40.1%), but the detection rate depended significantly on bowel preparation quality (p preparation (p 2.19-6.16) preparation relative to optimal preparation; however, no difference was observed at surveillance intervals >2 years. Bowel preparation quality significantly affects AMR. Colonoscopy should be repeated within 2 years in patients with suboptimal bowel preparation at index colonoscopy.